OUR PLEDGE TO YOU: When you buy W ebster products, you buy total service. Webster is the unique, single- source supplier of an extensive line of heat- ing products. W e manufacture fuel units, supply and transfer pumps, valves and oil heat accessories. And we constantly seek better solutions and set higher standards for the oil heat industry. Webster is committed to reliable servicing of its products. As always, our field service people provide professional schooling and make training materials and demonstration units available for training. We are ready to work with you to help solve your specific heating problems. An ISO 9001:2008 Company Webster ® Fuel Pumps & V alves A Division of Capital City Tool, Inc.
Transcript
Page 1: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

OUR PLEDGE TO YOU:

When you buy W ebster products, you buytotal service. Webster is the unique, single-source supplier of an extensive line of heat-ing products. W e manufacture fuel units,supply and transfer pumps, valves and oilheat accessories. And we constantly seekbetter solutions and set higher standards forthe oil heat industry.

Webster is committed to reliable servicing ofits products. As always, our field servicepeople provide professional schooling andmake training materials and demonstrationunits available for training.

We are ready to work with you to help solve your specific heating problems.

An ISO 9001:2008 Company

Webster®Fuel Pumps & ValvesA Division of Capital City Tool, Inc.

Page 2: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

This Webster® Service Technician's Handbook issupplied as a service to our customers, dealers andinstallers. It represents our efforts to share with themour experiences of many years with our productsin the field, and to also provide condensed cataloginformation to you on Webster products.

This booklet is not intended to be all-inclusive, orto be directly applicable to products manufacturedby any other company.

It remains the complete responsibility of all partiesinvolved in the design and installation of any systeminvolving Webster products to insure that thedesign and installation of the system is correct forthe individual circumstances, and that the systemis installed in compliance with all applicable codes,standards, regulations or other restrictions.

Neither Webster, nor any of its authorized repre-sentatives, assume any responsibility , obligationor liability relating to the design and/or installationof any systems utilizing Webster component parts,and nothing contained in this Service Technician'sHandbook should be construed as constitutingany extension of its standard W arranty Policy asstated in this booklet.

Webster®Fuel Pumps & Valves

Page 3: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

Warranty Policy

Webster warrants that Products shall be free from defects inmaterials and workmanship for a period of three (3) years fromthe date of manufacture or two (2) years from the date of instal-lation, whichever period expires first. W ebster will rebuild orreplace, at its option, all Products proven to its satisfaction to bedefective within such warranty period and returned to theWebster factory transportation charges prepaid. Webster's soleobligation and buyer's exclusive remedy hereunder is limited tosuch rebuilding or replacement.

No products may be returned to W ebster unless the prior writ-ten consent for said return shall have been obtained from theCustomer Service Department in Frankfort, Kentucky . ThisLimited Warranty does not cover shipping costs to and from theWebster factory, any costs for labor or otherwise related toproduct removal or replacement, or any other costs of anynature without prior written consent by Webster.

Parts, products and accessories made by others are warrantedonly to the extent of the original manufacturer 's warranty toWebster.

This warranty shall not apply to acts of God, war or civil insur-rection, nor shall it apply to products which, in the sole judge-ment of Webster, have been subject to negligence, abuse, acci-dent, misapplication, tampering, alteration; nor due to otherthan normal application, use or serv ice, including but not limitedto, operational failures caused by corrosion, rust or other foreignmaterials in the system, or operation at pressures in excess ofrecommended maximums.

Purchaser shall be solely responsible for determining suitabilityfor use of W ebster Products. W ebster shall not in any eventwhatsoever, have any liability with respect to such determination.

THE FOREGOING WARRANTY IS EXCLUSIVE AND INLIEU OF ALL OTHER W ARRANTIES, EXPRESS ORIMPLIED, INCLUDING BUT NOT LIMITED TO THEIMPLIED WARRANTIES OF MERCHANT ABILITY ANDFITNESS FOR A PARTICULAR PURPOSE. WEBSTERSHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL,INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER.

NOTE TO CONSUMERS: THIS LIMITED WARRANTY ISEXTENDED TO THE COMMERCIAL CUSTOMERS,DEALERS AND INSTALLERS OF WEBSTER ONLY. THESUPPLIER / INST ALLER WILL EXTEND W ARRANTYCOVERAGE TO YOU WHICH COVERS WEBSTER'SPRODUCTS. WEBSTER'S WARRANTY TO SUCH CUS-TOMERS, DEALERS AND INSTALLERS WILL BACK UPTHE WARRANTY EXTENDED TO THE CONSUMER.

i

Page 4: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

i

FUEL UNITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1General Information . . . . . . . . . . . . . . . . . . . . . . . 1

Oil Heating Terminology . . . . . . . . . . . . . . . . . . . 1How A Fuel Unit Works . . . . . . . . . . . . . . . . . . . . 1Basic System Installations . . . . . . . . . . . . . . . . 2-4Installation and Service Tips. . . . . . . . . . . . . . 5-12Service Call Checklist . . . . . . . . . . . . . . . . . 13-14

Metering Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . 14M Series Fuel Units . . . . . . . . . . . . . . . . . . . . . . . 15

Single- and Two-Stage . . . . . . . . . . . . . . . . . . . 15M34DK-3 Series Fuel Units . . . . . . . . . . . . . . . . 15

Single-Stage . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Fuel Unit Specifications . . . . . . . . . . . . . . . . . . 16Code Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . 17Selection Tables and Dimensions . . . . . . . . 18-19Fuel Unit Cross Reference . . . . . . . . . . . . . . . . 18Installation Data . . . . . . . . . . . . . . . . . . . . . . . . 20

BIO Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Waste Oil Pumps . . . . . . . . . . . . . . . . . . . . . . . . . 29R Series Service Saver Fuel Units . . . . . . . . . . . 31

Fuel Unit Specifications . . . . . . . . . . . . . . . . . . 31Selection Table—Single-Stage . . . . . . . . . . . . . 32Selection Table—Two-Stage . . . . . . . . . . . . . . . 34R Series Code Analysis . . . . . . . . . . . . . . . . . . 38Fuel Unit Cross Reference . . . . . . . . . . . . . 38-39Installation Data . . . . . . . . . . . . . . . . . . . . . . 40-47

1 R00 Series Single-Stage Transfer Pumps . . . 48 Fuel Unit Specifications . . . . . . . . . . . . . . . . . . . 48Selection Table . . . . . . . . . . . . . . . . . . . . . . . . . 49R Series Fuel Unit Code Analysis . . . . . . . . 49-50Installation Data . . . . . . . . . . . . . . . . . . . . . . . . . 51

V Series High Delivery Fuel Pumps . . . . . . . . . . 52Fuel Unit Specifications . . . . . . . . . . . . . . . . . . . 53Selection Table . . . . . . . . . . . . . . . . . . . . . . . 54-55V Series Code Analysis . . . . . . . . . . . . . . . . 56-57Installation Data . . . . . . . . . . . . . . . . . . . . . . 58-59

B Series Fuel Oil Transfer Pumps . . . . . . . . . . . 60Fuel Unit Specifications . . . . . . . . . . . . . . . . . . . 61Selection Table. . . . . . . . . . . . . . . . . . . . . . . . . . 61Typical Performance Curves. . . . . . . . . . . . . 62-63Installation Data . . . . . . . . . . . . . . . . . . . . . . . . . 64

SUPPLY PUMP UNITS . . . . . . . . . . . . . . . . . . . . . . . 65General Information . . . . . . . . . . . . . . . . . . . . . . . 66SPM Series Supply Units . . . . . . . . . . . . . . . . 67-68Duplex Pump Units—SPM Series . . . . . . . . . . . 69

Supply Unit Specifications . . . . . . . . . . . . . . . . 70Selection Tables . . . . . . . . . . . . . . . . . . . . . . 71-72Supply Unit Cross Reference . . . . . . . . . . . . . . 72Installation Data . . . . . . . . . . . . . . . . . . . . . . 73-81SPM Line Sizing . . . . . . . . . . . . . . . . . . . . . . . . 82Suction Line Sizing Charts . . . . . . . . . . . . . 83-86

TABLE OF CONTENTS

Page 5: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

ii

Discharge Line Sizing Charts . . . . . . . . . . . 87-94SPM Duplex Automatic Controls . . . . . . . . . . . . 95Electrical Connections . . . . . . . . . . . . . . . . . . . 96

SPMV Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97Fuel Unit Specifications . . . . . . . . . . . . . . . . 98-99SPMV Code Analysis and Selection Tables. . . 100-103

SPMB SERIES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 105SPMB Code Analysis . . . . . . . . . . . . . . . . 106-109

TRANSFER PUMP/MOTOR UNITS . . . . . . . . . . . . 110Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 110

35223 Series Transfer Units . . . . . . . . . . . . . . . 110Selection Table . . . . . . . . . . . . . . . . . . . . . . . . 111

35202 Series Transfer Units . . . . . . . . . . . . . . . 112Selection Table . . . . . . . . . . . . . . . . . . . . . 113-114

49116 Series Transfer Units . . . . . . . . . . . . . . . 115Selection Table . . . . . . . . . . . . . . . . . . . . . 115-116

FUEL UNIT ACCESSORIES . . . . . . . . . . . . . . . . . . 117Mounting Accessories . . . . . . . . . . . . . . . . . . . . 117

Selection Table . . . . . . . . . . . . . . . . . . . . . . . . . 117Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . 118

VALVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119OSV® Oil Safety Valves . . . . . . . . . . . . . . . . . . . 119Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119

BIO-OSV Upgrade . . . . . . . . . . . . . . . . . . . . . . 119Section “A” . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120Troubleshooting . . . . . . . . . . . . . . . . . . . . 120-121

Section “B” . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121Installation. . . . . . . . . . . . . . . . . . . . . . . . . 121-122Open Loop System . . . . . . . . . . . . . . . . . . . . . 123General Considerations . . . . . . . . . . . . . . . . . . 123Porting Connections. . . . . . . . . . . . . . . . . . . . . 123Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123Priming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123Check Local Codes . . . . . . . . . . . . . . . . . . . . . 123

Regulating Valves for Oil Heating . . . . . . . . . . 124RV Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124Specifications . . . . . . . . . . . . . . . . . . . . . . 124-125Selection Table. . . . . . . . . . . . . . . . . . . . . . . . . 126Installation Data . . . . . . . . . . . . . . . . . . . . . . . . 127

Relief Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128Vacuum Breaker (48598) . . . . . . . . . . . . . . . . . . 129

Installation Data . . . . . . . . . . . . . . . . . . . . . . . . 129

TROUBLESHOOTING General Pump Problems . . . . . . . . . . . . . 130-132

MANUFACTURER'S REPRESENTATIVES. . . 133-134

Page 6: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

1

FUEL UNITSGENERAL INFORMATIONOIL HEATING TERMINOLOGYAs with most major industries, oil heating has devel-oped a language of its own which contains a number ofterms not encountered elsewhere The following listincludes the terms which are most common to the oilheating industry.

Single-stage fuel unit: unit with one set of gears for bothsuction and pressure.

Two-stage fuel unit: unit with two sets of gears, one forsuction and one for pressure.

One-pipe system: one line, an inlet line, from tank tofuel unit.

Two-pipe system: two lines, one inlet and one returnline, from tank to fuel unit.

Bypass plug: small hex socket head pipe plug used toclose internal port and convert unit from one pipe to twopipe operation.

Bleed: to remove air from system.

Lift: oil drawn from a level below pump expressed in feetof lift or inches of mercury.

Head of oil: column of oil over fuel unit expressed in psior feet.

Inlet port: port which receives oil from tank.

Bypass port: port which discharges surplus oil back totank in two-pipe system.

Return line port: same as by-pass port.

Valve differential: number of pounds per square inch thepump pressure must drop from operating pressure toclose nozzle valve.

Delivery: gallons per hour pumped from the nozzle out-let assembly of the fuel unit.

Gear Set Capacity: Total amount of oil being displacedby the pumps gear set(s).

HOW A FUEL UNIT WORKS

The fuel unit performs three basic functions:

1. Supply the Oil. The pumping action,of the fuel unit isaccomplished by the gearset. In a single-stage fuel unitthere is only one set of gears. Their function is to drawoil from the tank and deliver the oil to the nozzle undersufficient pressure to ensure the oil is properly atomizedfor combustion. A single-stage fuel unit is generally

Page 7: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

2

used where the fuel supply tank is above the burner orwhere the inlet vacuum is limited to 10” Hg or less whenmeasured at an unused inlet port.

A two-stage fuel unit has two sets of gears. The suctiongearset creates a vacuum within the fuel unit whichdraws oil from a submerged tank or a tank locatedbelow the oil burner and discharges it into an intermedi-ate chamber or reservoir which supplies the pressuregears. The pressure gearset delivers oil under pressureto the burner nozzle. Thus, the pressure gears do noneof the lifting.

2. Clean the Oil. Clean oil isessential for the ef ficientoperation of any oil burner .The purpose of the filter is toprotect the nozzle from for-eign particles or any othermatter that might clog theminute nozzle opening.Webster fuel units utilize ourexclusive rotary filter whichreduces the need for trouble-some periodic cleaning. Therotary filter's blades rotate at motor speed with constantcleaning action to minimize clogging, compared tostrainer type filters. For maximum protection, an addi-tional line filter should be u sed, in accordance with rec-ommended standard practice.

3. Build Pressure and Provide Clean Fuel CutoffProbably the most important functions of the fuel unitare to build pressure to properly atomize the fuel oil andto provide clean cutof f of oil when the burner shutsdown. These functions are primarily performed by thevalve assembly consisting of a pressure regulatingspring, pressure adjusting screw, valve and valve seat,working in conjunction to the gearsets.

The pressure regulating spring and the pressure adjust-ing screw determine the pressure at which oil is deliv-ered to the nozzle. For example, when the spring in avalve assembly is set for 100 pounds per square inchpressure the valve will not open until the pressure gearshave built up enough pressure in the valve chamber toraise the piston from its seat. This prevents oil fromreaching the nozzle while under too low a pressure forcorrect atomization. The valve and valve seat controlthe flow of oil. They also are responsible for a sharpclean cutoff when the pressure within the fuel unit dropsbelow the setting of the valve spring. W ebster'sM34DK-3 fuel unit has exceptionally fast fuel cutof fthrough the additional use of an internal flow controldevice.

Page 8: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

3

BASIC SYSTEM INSTALLATIONS

There are two basic types of installation for fuel units:one-pipe systems or two-pipe systems.

The first of these, a one-pipe system, should not beconfused with a single-stage fuel unit. A one-pipe sys-tem can be installed employing either a single-stage ora two stage fuel unit. It is used where a gravity flow ofoil is available.

In a one pipe (single- or two-stage) system, the internalpumping capacity exceeds nozzle requirements. Theexcess flow is bypassed by the internal regulating valveand is recirculated within the pump. In the one-pipe con-nection, inlet line flow equals nozzle flow rate.

The second basic type is known as a two-pipe systemand should always be used wherever the oil supplylevel is below the fuel unit, whether it be a single or two-stage fuel unit.

On a two-pipe system there is a second pipe, called areturn line, between the fuel unit and the tank. Theexcess oil over and above that required by the nozzle isbypassed at the valve and returned to the tank.

A single-stage unit on a two-pipe system can be usedon lifts up to 10” HG. On the other hand, a two-stagewith a two-pipe system may be used on lifts up to 15” HG.

Existing Inside Tank Installation- One Pipe SystemTank Above Burner Level

With the conventional one pipe gravity feed installationboth furnace and water heater can be operated of f thesame suction line. Merely tee of f the present line towater heater as shown in drawing below making sure oilsupply is above burner level at all times.

Existing Outside Tank Installation—Tank Above Burner Level

The water heater may be added to the system by con-necting the suction line to the furnace suction line as

Page 9: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

4

shown in drawing below . No return line is necessaryfrom the water heater as the system is flooded due tothe siphoning action when the tank is above burnerlevel.

Existing Outside Tank Installation —Tank Below Burner Level

The water heater may be added to the system byinstalling a check valve in the suction line at both fuelunits as shown in drawing below. Both units must be setfor (2) two-pipe operation. This method should only beused when it' s impossible to add an independent suctionline to the water heater as shown in bottom drawing

New Outside Tank Installation —Tank Below Burner Level

Individual suction lines should be used on all new instal-lations. Return lines may be manifolded as shown indrawing below.

Page 10: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

5

INSTALLATION AND SERVICE TIPS

When installing and servicing oil heating fuel units, sev-eral key points including service tools, use of propertubing sizes, fuel supply cut-off, and possible causes ofseal failure should be understood.

Effective Gauge Use

There are valuable tools needed in servicing any fuelunit, the two most essential are the pressure gauge andthe vacuum gauge. It is factua lly known that if thesegauges were used consistently , 75% of the fuel unitssent in for repair would never need to be removed fromthe burners. With the correct use of these two gauges,it is possible to check vacuum, lift, air leaks, delivery ,pressure and cut-off.

Vacuum Gauge

The vacuum gauge can determine the existence of airleaks in the suction line. For example, if checking a sys-tem in which the tank is buried below the burner leveland the oil passes through a line filter , the vacuumgauge must show a reading. If the gauge does not showa reading, an air leak is present.

NOTE: When installing fuel units, to assure compliancewith National Fire Protection Association's bulletin 31,“Installation of Oil Burning E quipment”, fuel unit inletpressures should not exceed 3 psig.

Vacuum Data

Before removing a fuel unit from an oil burner , a checkshould be made with vacuum and pressure gauges ifyou suspect fuel unit trouble.

The vacuum gauge should be applied to the inlet port(“IN”) opposite the inlet port being used, or inserted inthe inlet line with a “TEE”.

Pressure Gauge(100 psi Operating

Pressure)

Nozzle Line

Inlet Line

Vacuum Gauge(Optional Inlet Connection)

Return Line(When Used Two Pipe

Page 11: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

6

On installations where the oil tank is below the fuel unit,the gauge reading should show t he amount of vacuum(approximately 1" vacuum per 16" of vertical lift, plusthe tube loss of total run).

NOTE:

1. The viscosity chosen for the above figures is 50 SSU.The above losses will be reduced at lower viscosities.

2. The gravity chosen is 40° API (60°F) at 68°F, whichgives a specific gravity of 0.822. Gravity of No. 2 oilsvaries from 30° to 45° API.

3. Even though a fuel unit is capable of a very high vac-uum, this has very little to do with the maximum advis-able lift because of the volatility of the oil under vacuum,which varies with dif ferent oils. Under certain condi-tions, installations as high as 28 feet have operatedsat-isfactorily with a two-stage unit, but generally high liftsshould be avoided on any liquid having volatile frac-tions. When the combined vertical lift and the equivalentlosses through the tubing add up to 10” vacuum or morefor single-stage pumps, 15” vacuum or more for two-stage pumps, use of a W ebster supply pump unit isadvisable.

If the vacuum gauge reads higher than the calculatedvacuum, look for restriction in the suction line ... aclosed tank valve, kink ed copper tubing, plugged filter ,sticking foot or check valve, frozen oil line, undersizedoil line, or excessive oil lift. On the other hand, if thegauge reading is below the calculated vacuum, look forair leaks in the lines, valve, fittings, or fuel unit.

On gravity fed jobs where the oil tank is above the fuelunit, vacuum should read zero except when restrictionsare apparent such as closed shut-of f valve, clogged fil-ter, kinked line, etc. Any of these restrictions should beeliminated.

Relation between vacuum and vertical lift40° API all at 68° F

Ins. of Ins. of Ins. ofVacuum Lift Vacuum Lift Vacuum Lift

1 1'4” 8 11'0” 15 20'7”

2 2'9” 9 12'4” 16 22'0”

3 4'1” 10 13'9” 17 23'4”

4 5'6” 11 15'1” 18 24'9”

5 6'10” 12 16'6” 19 26'1”

6 8'3” 13 17'10” 20 27'6”

7 9'7” 14 19'3”

Page 12: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

7

Pressure Gauge

The pressure gauge, on the other hand, shows whetherthe gears are pumping and building up a steady evenpressure to deliver oil to the nozzle. It also showswhether the shut-off valve in the nozzle line is giving apositive cut-off of the oil flow.

Pressure Data

A pressure gauge applied to the pressure gauge portreveals the pressure to which the fuel unit has been reg-ulated. An adjustment can be made to suit the firingconditions (usually 100 psi). Also the pressure gauge,when applied to the pressure gauge port, can be usedto check fuel unit ef ficiency. A unit in satisfactory oper-ating condition should be able to support a nozzle at fullspray, up to several psi above the rated burner pres-sure. Fuel unit manufacturers typically rate domesticunits for maximum burning rate at a nominal 100 psi.Collapse of nozzle spray below specified limits indicateseither excess bypass, missing or damaged valve gas-ket, worn valve piston or sleeve, worn gear set, or pumpRFS less than nozzle rating. Pumping capacity alsodecreases under correspondingly higher lift (or vacuum).

A pressure gauge applied directly to nozzle outlet portfor cut-off check should hold dif ferential pressure onshutdown. For example, with operating pressure of 100psi, the cut-of f should be approximately 80 psi. If thepressure gauge drops below the cut-off point, this wouldindicate a leak at cut-of f, therefore the valve assemblyshould be disassembled, cleaned or replaced if neces-sary. Cut-off pressure must never be more than 20%below set operating pressure.

To determine what pressures should be provided byeach pump, refer to the selection charts in the desiredmodel sections.

Correct System Tubing Sizing

Many people both in engineering and in service makethe mistake of laying out and installing jobs with tubingwhich is too small in diameter and too long in length. If

Return Line

Inlet Line

75-90 psi cut-of f point shouldhold. If pressure drops back tozero, indicates leaky cutoff.

Page 13: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

8

a fuel unit with a pumping capacity of not more than 30gallons per hour is used, tubing of 1/2” OD can be usedwith safety.

The tubing size can vary widely depending upon flowrate. See the pipe sizing charts for help in determiningwhich tubing size is best suited for each application.

To Determine Suction Line Size in InstallationsUsing Webster Fuel Units on Two-Pipe Systems

1. Check suction gear capacity (see table of pumps).

2. Measure total tube length (horizontal and vertical).

3. Refer to “Friction Tube Loss Chart” for desired tubingsize. Read up from line “total feet of copper tube” to“suction capacity” in gph.

4. Read left to column “inches of vacuum at fuel unit”.(This is vacuum required to draw oil through tube listedof given length.)

5. If installation has lift add .75” of vacuum for every footof lift.

Rule of Thumb:

A quick rule to check an installation is to figure 1”of vacuum for every foot of vertical lift, and 1” ofvacuum for every 10' of horizontal run Refer toFrictional Tube Loss charts for actual installation data.

6. Total inches of vacuum (frictional tube loss plus lift ifany).

7. If total is over 10” when single stage is employed ontwo-pipe system, check on next larger tube size chartfor proper tube size.

8. If total is over 15” when two-stage unit is employedon a two-pipe system, check on next larger tube sizechart.

9. The above does not allow for any added restrictionssuch as line filter, elbows, sharp bends, check valves, etc.

On high lifts and long runs, too small tubing will causethe oil to separate and have a milky appearance. This isnot air, it is actually light, volatile portion of the oil sepa-rating from the heavy portion. This is likely to occur anytime the vacuum gauge shows a reading of 15” or more,and may occur at a lower vacuum with some oils. Whenvacuums of 20” to 22” are reached, the pressure gaugewill start to bounce and delivery at the nozzle will beginto fall off. To correct these conditions, check the tubing.If the tubing size is correct and there are no kinks orother restrictions, a supply or booster pump may be

Page 14: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

9

required to assure the fuel unit of a solid column of oil.This is especially desirable where a series of suspend-ed furnaces are included in the system with high liftsand long horizontal runs.

Page 15: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

10

Page 16: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

11

Checking Fuel Cut-Off

Another error made by some is to say the valve is faultyor the unit has a poor shut-of f when the real trouble isair trapped in the nozzle line between the fuel unit valveand the nozzle itself.

This condition is generally found when a new installa-tion is made or when air enters the suction line due topoor joints. This is particularly true on high vacuuminstallations. When air is mixed with oil and pumpedthrough the fuel unit into the combustion chamber , agood fire can result while the burner is in operation.However, on shut-down the valve closes and the airbecomes trapped between the valve and the nozzleitself. This air is no longer under pressure and the bub-ble expands forcing the oil through the nozzle orificeinto the combustion chamber . This is not poor cut-of fbut trapped air causing the oil to squirt. It is necessaryto have a tight installation and to purge all air in order tohave clean sharp cut-off.

REMEMBER: A squirt out of the nozzle after the burnerstops means that air is trapped. Get rid of the air andthe problem will be gone.

This condition is found less often in a two-pipe systembecause air is picked up in the suction line, is dis-charged into the by-pass chamber of the fuel unit andreturned to the tank if the leak is not too large. However,air can be trapped in the nozzle line of the two-pipe sys-tem. Several hours of burner running may be necessarybefore the air is absorbed by the oil and passed throughthe nozzle.

Fast Cut-Off Required

Unlike heating equipment of the past, compact boilers,furnaces, domestic water heaters, and burners madetoday require substantially faster shut-of f to eliminatepulsation on starts and stops. The valve must open andclose while the fan speed is high to provide enoughoxygen for complete combustion. This may be accom-

Page 17: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

12

plished by using a solenoid valve which cuts off the flowof oil instantly on shut-down.

Since the use of a solenoid is often costly for someinstallations, Webster offers the M34DK-3 as a fastshut-off alternative. In this unit the valve opens andcloses at approximately 2, 400 rpm fan speed. At thisspeed the air pattern is well established, both in thetube and in the chamber, and the burner operates with-out a smoke plume, eliminating pulsation on starts andstops. The volume of air delivered by the fan at such aspeed provides the oxygen necessary for completecombustion insuring clean, quiet operation when theburner is set at maximum efficiency.

Checking Seal Leaks

Seal leaks generally do not occur; they are caused. Itmust be remembered that a seal can be operated underconditions ranging from high vacuum to pressure (psi).Where there is a head of oil over the fuel unit, a pres-sure gauge can be installed in the suction port of theunit to check head pressure. If the head pressure isover 3 psi an oil safety valve (OSV) should be installedin the suction line between the oil tank and the unit.

This also holds true where there are pressurized linesleading to the fuel unit, such as a series of suspendedfurnaces being served by a supply pump.

REMEMBER: To comply with NFPA standards, fuel unitinlet pressures must be limited to 3 psi.

If Pump Doesn't Work, Check for Air Leaks

90% of start-up problems are due to air leaks in the suctionline. Be sure to double check for air leaks if there a reproblems with poor cutoff, noisy operation, or erratic fire.

To inspect for air leaks, check to be sure return line issubmerged. Also, check all fittings, all joints, and theoptional inlet plugs for tightness.

Check for air leaks:❏ Return line must be submerged❏ Check all fittings❏ Check all joints❏ Check optional inlet plugs❏ DO NOT use compression fittings

90% of start-up problems are due to air leaks in the suc-tion line . . . So check ✔ and doubt check ✔ for airleaks.

Page 18: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

13

Filter Use

Both the Webster M and R Series contain an internalrotary filter. In addition to this filter , it is recommendedthat an external filter be us ed. The self cleaning rotaryfilter is designed to prolong fuel unit life and reduce fuelunit maintenance. It is not intended to be a replacementfor the external filter.

IMPORTANT: Use of non-hardening oil pipe dope isrecommended on threads of all fittings. Do not loosen ortry to tighten any pump plugs not to be used in theinstallation. Do not use Teflon Tape. Evidence of teflontape use will be cause to void all warranties.

SERVICE CALL CHECKLIST

The following procedure has been established to helpsave on service time and needless work when checkinga “no heat” service call. This procedure is intended to beused by qualified heating service technicians only.

1. Check the thermostat to make sure that corrosion,dust or other foreign matter are not causing faulty con-tact and switches are properly set.

2. Check both the main fuses and the oil burner circuitfuses. Replace if required.

3. Check the oil supply and the shut-of f valve in the oilline. Adequate oil and open valve are required.

4. Open the door of the heating plant and see if there israw oil on the walls of the combustion chamber

5. Leave the inspection door open and press the burneroil reset button.

6. Check the oil burner controls in accordance with theoil burner manufacturer's instructions.

7. If at any point on the foregoing checks the burneroperates, observe it for two or three complete cycles todetermine whether the stoppage may occur.

8. If the burner does not operate, check to see if motor ,fan and pump shaft are all rotating.

9. If there is oil spray but no ignition, check all electricalconnections and the transformer.

10. If the electrical connections and transformer areoperating properly, remove the firing assembly andcheck the electrodes for coking, spading, and crackedporcelains.

11. While the firing assembly is out of the heating plant,clean or replace nozzle.

12. If no oil spray appears, check the line filter and thefuel unit, using vacuum and pressure gauges.

Page 19: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

14

Vacuum gauge check usually covers the suction side ofthe system.

Pressure gauge determines efficiency of pumping gearsand valve. The valve can be serviced in the field. Wornpumping elements require the removal of the fuel unit.

Though these instructions may seem obvious, strictadherence to the sequence given can save valuableservice time when time is of importance.

METERING PUMP

MODEL # M17DN-M

Metering Pump for the air atomized waste oil burnermarket. Variable flow rates vs. RPM. Clockwise rotationlooking at shaft V iton seal. This unit is comparable tothe Suntec A2RA-7710 Pump.

Page 20: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

15

M34DK-3 SERIES FUEL UNITSSINGLE STAGE UNITS

To meet the needs of today' s fuel-efficient, downsizedand space efficient burners, Webster's popular M34DK-3incorporates improved access to both the bleed valveand bypass plug. Locating the bleed port plug assemblyon the side of the fuel unit prov ides the service techni-cian with one visible and accessible location to eitherbleed the fuel unit or change the bypass plug withoutremoving the burner . The M34DK-3 retains all of theindustry accepted, state-of -the-art features of theM34DJ-3 fuel unit. These include faster fuel cut-of f,improved priming on one-pipe installations, and reducedinlet line flow on two-pipe systems which results inreduced line noise. W ebster'sM34DK-3 fuel unit is avail-able in a single s tage,3450 RPM model ratedat 3 GPH. Operatingpressure is factoryset at 100 psi and isadjustable to 150 psi.The M34DK-3 is capa-ble of maintaining its 3gallon per hour fire sizeat up to 150 psi through-out its service life.

M SERIES FUEL UNITSSINGLE- AND TWO-STAGE

Light and extremely compact, the Webster M Series fuelunits have earned a reputation for reliability and efficiency.All units include the W ebster internal rotary filter . Therotary filter reduces the need for troublesome periodiccleaning. Because the filter blades rotate at motor speedwith constant cleaning action, clogging is minimal comparedto units that use internal filter screen. For maximum pro-tection, an additional line filter is recommended in accor-dance with standard practice. Another popular feature isthe easy-to-bleed valve assembly located on the side. A“D” drive reduces the harmful ef fects low-lubricity fuelshad on previous key-drive designs. Simple flange mount-ing and side-located nozzle ports make the M Seriesideal for fuel unit servicing. M Series fuel units are availablein single- or two-stage, 1725 and 3450 rpm models withcapacities to 15 gph.

Page 21: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

16

FUEL UNIT SPECIFICATIONS

M SeriesSingle- and Two-Stage Units

M34DK-3 Fuel UnitsSingle-Stage Unit

Capacities:M Series rated 3 gph @ 100 psi with #1, #2 fuel oil orkerosene.M34DK-3 unit rated 3 gph fire size for pressure from100 to 150 psi with #1, #2 fuel oil or kerosene.

Pressure:Built in pressure regulator.M Series factory set at 100 psiM34DK-3 unit factory set at 100 psi, adjustable to 150 psi.

Speeds: M Series—1725 and 3450 rpm M34DK-3—3450 rpm.

Rotation: Clockwise (D Style) or counterclockwise (C Style) whenviewed from shaft end.

Porting:1/8” NPTF: side location nozzle port, top located gaugeport1/4” NPTF: 2 inlets, and bottom return.

Shaft:5/16” dia. x 1.65” extension from mounting face withkeyless “D” drive.

Seal: Double lip type Buna N.

Mounting: Two bolt flange.

Filter: Self cleaning rotary type internal NOTE: External filter recommended with each installation

Weight: (shipped oil filled)M17 models—4 Ibs, 4 ozM34 models—4 Ibs, 2 oz2M17 models—4 Ibs, 12 oz2M34 models—4 Ibs, 9 oz

Maximum Inlet Vacuum: M models—10” Hg 2M models—15” Hg Refer to Table “Total Allowable Feet of Line” in this sec-tion.

U.L. Listed.To assure compliance with National Fire ProtectionAssociation's Bulletin 31,” Installation of Oil BurningEquipment,” fuel unit inlet pressure should not exceed 3 psig.Refer to the section on Oil Safety Valves (page 119) foradditional information.

Page 22: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

17

M-SERIES FUEL UNIT-CODE ANALYSIS

A— M = Single Stage2M= Two Stage

B— 17 = 1725 RPM34 = 3450 RPM

C— C = CCW rotation, outlet leftD = CW rotation, outlet right

(as viewed from shaft end)

D— A = Key drive, face seal, old style portingB = Std., face seal, old style portingC = Special, face seal, old style portingD = Std. lip seal, old style portingE = Special, lip seal, old style portingF = Same as D except revised portingG = Same as E except revised portingH = Same as F except o-ring on pressure

adjusting screwJ = Same as H except revised internal portingK = Same as J except revised porting and bleed

valve locationL = Same as K except revised porting and

bleed valve locationM = BIO PumpN = Waste Oil Pump

E— 3 = 3gph max. recommended fire size6 = 6gph max. recommended fire size15 = 15gph max. recommended fire sizeM = Metering Pump

F— No *=unit set 1 pipe(bypass plug not installed)

*=Unit set 2 pipe(bypass plug installed)

Page 23: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

18

DimensionsThe dimensions indicated apply to both M Model, sin-gle-stage units, and 2M Model, two-stage units. Refer totable for variable dimension X.

Dimension drawing shows nozzle, inlet and gage portlocations for D Style units. C Style units are the oppo-site of that pictured.

M Model Unit—Single-StageMax. Suction

Nozzle Fire GearSpeed Rota- Loca- Size Cap.**

Models rpm tion* Style tion* gph at 100 psiM17CL-6 1725 CCW C Lett 6 32M17DL-6 1725 CW D Right 6 32M34CL-3 3450 CCW C Left 3 29M34DK-3 3450 CW D Right 3 17M34CL-6 3450 CCW C Left 6 29M34DL-6 3450 CW D Right 6 29*As viewed from shaft end** Based on two-pipe installation2M Model Unit—Two-Stage

Max. SuctionNozzle Fire Gear

Speed Rota- Loca- Size Cap.**Models rpm tion* Style tion* gph at 100 psi

2M17CL-6 1725 CCW C Left 6 352M17DL-6 1725 CW D Right 6 352M34CL-3 3450 CCW C Left 3 352M34DL-3 3450 CW D Right 3 352M34CL-6 3450 CCW C Left 6 352M34DL-6 3450 CW D Right 6 35*As viewed from shaft end** Based on two-pipe installationFUEL UNITS (CROSS REFERENCE)

Webster Model No. Suntec Model No.M17DL-6 A1VA-7112M17DL-6 A1VB-7113M17CL-6 A1VC-7114M34DK-3 A2VA-7116M34DK-3 A2VB-7117M34DK-3 A2VA-7142M17CL-6 A1VD-7741M17DL-6 A1YA-7912M17CL-6 A1YD-7915M34DL-6 A2YA-7916

2M17DL-6 B1VA-82122M34DL-3 B2VA-82162M34DL-6 B2YA-8916

SELECTION TABLES & DIMENSIONS

Page 24: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

19

Page 25: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

20

INSTALLATION DATAM Series units may be used in one-or two-pipe installa-tions They have vacuum capability up to 10” Hg on sin-gle-stage units, 15” Hg on two-stage units including pip-ing and lift losses. They are rated for use with #1 and #2fuel oil or kerosene.

IMPORTANT: Do not loosen or try to tighten any pumpplugs not to be used in the installation. NON HARDEN-ING OIL PIPE DOPE IS RECOMMENDED for use onthe threads of all fittings. Teflon tapes or paste must beused with care to prevent depositing tape pieces orfibers into critical int ernal areas of the pump. Reducedtorque must be used with teflon materials to avoidthread or casting damage EVIDENCE OF TEFLONMATERIAL IN INTERNAL AREAS OF THE FUEL UNITWILL BE CAUSE TO VOID WARRANTY.Installation Notes:

Nozzle port pressure at cutof f is not less than 80% ofset pressure on all except -15 models. -15 models donot have internal cutoff.

ʻFuel unit inlet pressure should not exceed 3 psig inorder to comply with National Fire ProtectionAssociation's Bulletin 31.”

M Series fuel units are available in standard C Style(counterclockwise rotation, nozzle port on left, asviewed from shaft end) or D Style models (clockwiserotation, nozzle port on right, as viewed from shaft end).

Important Rating Information

Recommended fire size (RFS) of pump decreasesas pump operating pressure is increased above 100psi nominal rated pressure, except M34DK-3, whichis rated to 150 psi. For adequate service life, nozzleflow at set pressure must not exceed RFS figures intable below.

Max. UL listed operating press. = 135 psi (“K”-150 psi)

RFS at RFS at RFS atPump Model 100 psi 135psi 150 psi

M34-3, 2M34-3 3 gph 1 gph —M34-6, 2M34-6 6 gph 3 gph —M34-15, 2M34-15 15 gph 13 gph —M17-6, 2M17-6 6 gph 3 gph —M17-15 15 gph 13 gph —M34DK-3 3 gph 3 gph 3 gph

Page 26: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

21

P/N

295

33-2

1

Page 27: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

22

Total Allowable Feet of Tubing

Figures in body of table are total allowable feet of linelength (vertical + horizontal) given feet of vertical lift forM pumps set 2 pipe.

1-StageAll Models 1-Stage

Feet Except “K” “K” OnlyVertical 3/8” OD 1/2”OD 3/8” OD 1/2” OD

Lift Tubing Tubing Tubing Tubing0 50 100 100 1001 46 100 93 1002 42 100 85 1003 39 100 78 1004 35 100 70 1005 31 95 63 1006 27 83 55 1007 24 72 48 1008 20 60 40 1009 16 49 33 9910 12 38 25 7611 27 18 5312 15 31131415161718

2-StageAll Models

Feet Except - 15 2M34-15 OnlyVertical 3/8” OD 1/2”OD 3/8” OD 1/2” OD

Lift Tubing Tubing Tubing Tubing0 75 100 56 1001 71 100 53 1002 68 100 51 1003 64 100 48 1004 60 100 45 1005 56 100 42 1006 53 100 39 1007 49 100 37 1008 45 100 34 1009 41 100 31 9410 38 100 28 8511 34 100 25 7712 30 91 22 6813 26 80 19 6014 23 68 17 5115 19 57 4316 46 3417 34 2618 23

Page 28: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

23

On

e-P

ipe

Inst

alla

tio

n

Nor

mal

ly r

ecom

men

ded

for

grav

ity fe

ed o

nly

. Li

ft up

to8

feet

max

. is

allo

wab

le if

sys

tem

is a

bsol

utel

y ai

rtig

ht.

Eve

n sl

ight

air

leak

can

cau

se lo

ss o

f prim

e w

ith 1

pip

e lif

t.

1.

Rem

ove

BY

PA

SS

P

LUG

(if

inst

alle

d) th

roug

h si

de

INLE

T P

OR

T in

pum

p bo

dy.

2. C

onne

ct in

let l

ine

to p

refe

rred

INLE

T P

OR

T.

3. C

onne

ct n

ozzl

e ou

tlet t

o no

zzle

line

.

4. P

lug

all u

nuse

d po

rts

secu

rely

.

5. S

tart

bur

ner

and

blee

d al

l air

from

the

syst

em b

y

open

ing

VE

NT

PLU

G. C

lose

VE

NT

sec

urel

y w

hen

oil f

low

in tu

be is

cle

ar.

Page 29: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

24

Two

-Pip

e In

stal

lati

on

Nor

mal

ly r

equi

red

whe

n lif

ting

oil f

rom

bel

ow p

ump.

2 p

ipe

syst

ems

are

self-

vent

ing.

See

tabl

e be

low

for

perm

issi

ble

line

leng

ths.

Max

imum

Inl

et V

acuu

m:

Sin

gle-

stag

e M

uni

ts—

10”

Hg

Two-

stag

e 2M

uni

ts—

15”

Hg

1. I

nser

t BY

PA

SS

PLU

G, i

f not

inst

alle

d, th

roug

h si

de IN

LET

PO

RT

in p

ump

body

.

2. C

onne

ct s

uppl

y lin

e to

pre

ferr

ed IN

LET

PO

RT.

3. C

onne

ct r

etur

n lin

e to

pre

ferr

ed R

ET

UR

N P

OR

T.

4. C

onne

ct n

ozzl

e ou

tlet t

o no

zzle

line

.

5. P

lug

all u

nuse

d po

rts

secu

rely

6. S

tart

bur

ner.

Uni

t will

sel

f ven

t.

Page 30: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

25

FeaturesTo meet the needs of today' sfuel-efficient, downsized andspace efficient burners,Webster's M34DM-3 incorpo-rates improved access to boththe bleed valve and bypassplug. Locating the bleed port plug assembly on the sideof the fuel unit provides the service technician with onevisible and accessible location to either bleed the fuelunit or change the bypass plug without removing the burner.

In addition to improved access the M34DM-3 cleanerblade has been thickened to provide a more robustcleaning action. For maximum protection, an additionalline filter should be used in accordance with recom-mended standard practice All of the BUNA-N elastomershave been replaced with VITON to provide extended lifeat critical locations within the fuel unit.

The M34DM-3 retains all the industry accepted, state-of-the-art features of the M34DK-3 fuel unit. These includefaster fuel cut-off, improved priming on single pipe instal-lations. This unit can easily replace your standard M34Dor A2VA residential pump.

The M34DM-3 is capable of maintaining a three gallonper hour fire size at up to 150 PSI throughout its designlife. The M34DM-3 is factory preset to 100 PSI and isadjustable to 150 PSI.

General Operation and Fuel Unit Oil FlowThe compact M34DM-3 Fuel Unit is engineered for ef fi-cient pumping of Bio fuel. The cut-away view illustratesthe oil flow through an M34DM-3 operating in a one pipesystem, with a suction line and no return to the storagetank.

A one pipe system is frequent ly used when the storagetank is located above the fuel unit, or when automaticventing is not necessary . Vacuum at the pump inletshould not exceed 10” Hg. For this type of installation tobe reliable, the total system must be completely airtight.During installation or servicing of the fuel unit, air may bemanually bled from the system through the side-locatedbleed valve.

The M34DM-3 will provide up to 10” Hg of inlet vacuum.The two pipe system (shown below), with both a suctionand return line is self-venting. This allows any air in thesystem to escape and be returned to the storage tankthrough the return line.

M34DM-3 Bio Pump

Page 31: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

26

One Pipe SystemFuel enters the fuel unitthrough the inlet port and isdrawn into the front coverchamber. A vacuum, creat-ed by an inner and outerrotating gear set, pulls oilthrough the rotary filter andinto the gears. As oilmoves around the gears, itis compressed, creating ahigher pressure. Oil leav-ing the gear set branchesinto two paths. One path leads to the pressure regulat-ing chamber. A second path directs oil to the bleedvalve. Oil flowing into the pressure regulating chamberbranches into two paths. Up to three gallons per hourcan flow out the nozzle port, and the remaining oil by-passes the pressure regulator , returning to the frontcover chamber.

■ Fuel subject to vacuum

■ Fuel at atomization pressure

■ Fuel at return pressure

Two Pipe SystemThe by-pass plug, inserted through the bleed valve port,blocks the surplus oil return to the front chamber . Thisoil is directed to the return port and back to the storagetank.

Page 32: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

27

Specifications

Firing Capacity:Recommended to 3 GPH fire size for pressures from100 to 150 PSI with #1, #2 fuel oil, Kerosene, orBio Fuel B100-B5 Bio Diesel

Gear Capacity:25 GPH @ 100-150 PSI with #1, #2 fuel oil, Kerosene,or Bio Fuel. B100-B5 Bio Diesel.

Pressure:Factory set at 100 PSI.Adjustable to 150 PSI.

Inlet Requirements:10” Hg maximum vacuum (approx. 10' vertical lift -exact distance will vary with tubing diameter andlength). 3 psig maximum inlet pressure.

Speed:3450 RPM.Rotation: (As viewed from shaft end): Clockwise(D Style).

Porting:• 1/8” NPTF, side located nozzle port.• 1/8” NPTF, top located gauge port.• 1/4” NPTF, bottom and cover located inlet ports and

bottom located return port.• Bypass plug accessible through the side located

bleed port plug assembly.• 3/8” flow through bleed valve.

Nozzle Location:(As viewed from shaft end):Clockwise (D Style) - Right side.

Shaft:5/16” dia., 1.65” extension from mounting face, withkeyless “D” drive.

Filter:Self-cleaning rotary type.

Elastomers:VITON shaft seal.All other seals are VITON.

Mounting:2 bolt flange - see interface dimensions.

Page 33: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

28

Dimensions Dimensions in inches, ( ) = cm

Weight:4 lbs., 2 oz., shipped oil-filled.

NOTE: To assure compliance with National FireProtection Association Bulletin 31, “Installation of OilBurning Equipment”, fuel unit inlet pressure should notexceed 3 psig.

Page 34: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

29

Waste Oil Pumps

SK41906 and SK41982

Webster now has available a Mini waste oil pump.Webster's waste oil pumps are available in single stagemodels, rated at 15 gph for the SK41906 (3450rpm) and20 gph for the SK41982 (1725rpm). Operating pressureis factory set at 100 psi. These waste oil pumps are ableto maintain their recommended flow rates throughoutthe 100 to 150 psi pressure range.

1RR SERIES

RPM Rotation GPH Rated PSI

1RR140D-4EK13 1725 CW 10 45

1RR243D-4EK13 1725 CW 20 45

1RR244D-4EK13 1725 CW 40 45

This single stage waste oil pump operates at 1725 rpm.The operating pressure range is 30-50 psi. Maximuminlet vacuum 10” Hg. V iscosity range is 34-7000 SUS(2.5 Centistokes), temperature range 40 F (min) - 160 F(max). This unit can be hub or flange mounted. Thepump can be used on one or two pipe installations.Double lip type V iton seals assure low starting torqueand provide positive protection from leaks. For waste oiland #4 or lighter fuel oils.

Page 35: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

30

H.P

.V

olt

age

RP

MR

ota

tio

nG

PH

Rat

ed P

SI

SP

M-2

5AT

1RR

140

¼12

017

25C

W10

45

SP

M-2

5AT

1RR

243

¼12

017

25C

W20

45

SP

M-2

5AT

1RR

244

¼12

017

25C

W40

45

The

se u

nits

hav

e th

e sa

me

char

acte

risti

cs a

s th

e 1R

R m

odel

s bu

t inc

orpo

rate

s a

120

volt,

sin

gle

phas

e, 1

/4 h

p m

otor

.

Gen

eral

Sp

ecif

icat

ion

s

• S

ingl

e S

tage

• S

ingl

e pi

pe o

pera

tion

only

whe

n us

ed w

ith th

ick

oil.

• 17

25 R

.P.M

.

• O

pera

ting

pres

sure

ran

ge 3

0-50

P.S

.I.

• V

isco

sity

ran

ge 3

4–70

00 S

US

(2.

5-15

00 C

entis

toke

s).

• S

haft

seal

and

pis

ton

valv

e ar

e V

iton®

mat

eria

l.

• B

ypas

sing

noz

zle

type

.

• P

ower

Req

uire

men

ts:

1/4

H.P

.for

visc

osity

less

than

100

0 ce

ntis

toke

s

1/3

H.P

.for

visc

osity

gre

ater

than

100

0 ce

ntis

toke

s

• 3/

8” In

let P

ort

• 1/

4” D

isch

arge

Por

t

• S

haft

Leng

th is

3 1

/8”

long

from

mou

ntin

g fa

ce to

sha

ft en

d.

• P

ump

body

has

a fl

ange

and

a h

ub.

• M

axim

um fl

ow is

10-

40 G

.P.H

. de

pend

ing

on m

odel

.

14.4

4

4.72

4.88

Page 36: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

31

R SERIES SERVICE SAVER FUEL UNITS

Available in both single-and two-stage models,Webster's service saver fuel units are rated to capaci-ties of 80 gph. Featuringthe unique Webster rotaryfilter, simple flange mount-ing, and an extendedshaft length, the R Seriesis adaptable to virtuallyevery replacement need.

FUEL UNITSPECIFICATIONSR Series Fuel UnitsCapacities to 80 gphSingle- and T wo-StageModels

Capacities:R Series models are rated to 80 gph at 100 psi with #2fuel oil.

Pressure:Built in pressure regulator.Factory set at 100 psi (supply pumps set at 20 psi).

Speed:1425,1725,2850 or 3450rpm.

Rotation:Clockwise (D Style) or counterclockwise (C Style) whenviewed from shaft end.

Porting:1 /8” NPTF: side location nozzle port if pump code endsin 3 or 4.1 /4” NPTF: side location nozzle port if pump code endsin 13 or 14.1 /4” NPTF: 2 inlets, gauge port and top and bottomreturns.

Shaft:7/16 x up to 3.69” extension from mounting face, keydrive.Stepped shafts turned to 5/16” at coupling end.

Seal: Mounting:Double lip type. Two bolt flange.

Filter: Self cleaning rotary type - internal. NOTE: External filter recommended with each installation.

Maximum Inlet Vacuum:Single-stage units - 10” HgTwo-stage units - 15” Hg

U.L. Listed to 72 gph:To assure compliance with National Fire ProtectionAssociation's Bulletin 31, “Installation of Oil BurningEquipment,” fuel unit inlet pressure should not exceed3 psig.

Page 37: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

32

SE

LE

CT

ION

TA

BL

E —

SIN

GL

E S

TA

GE

Max

imu

mV

aria

ble

No

zzle

&W

atta

ge

Su

ctio

nD

im “

X”

Slo

ttin

gN

ozz

leR

ated

Req

uir

emen

tG

ear

Mo

del

Typ

eS

ee p

g. 3

4C

od

eC

uto

ff@

Rat

ed p

si@

100

psi

Pre

ssu

re@

Rat

ed p

siC

apac

ity

1R11

13.

13”

1,2

Yes

5 G

PH

8 G

PH

150P

SI

60 W

atts

20 G

PH

310

GP

H12

GP

H

1R15

13.

13”

1Y

es8

GP

H8

GP

H10

0 P

SI

50 W

atts

20 G

PH

1R12

23.

13”

3Y

es12

GP

H15

GP

H30

0PS

I14

0 W

atts

30 G

PH

1R16

23.

13”

5,6,

15Y

es

7 G

PH

9 G

PH

125

PS

I70

Wat

ts30

GP

H

1R21

33.

75”

1Y

es21

GP

H23

GP

H15

0 P

SI

110

Wat

ts50

GP

H

21R

150

3.13

”5

Yes

5 G

PH

5 G

PH

100

PS

I55

Wat

ts30

GP

H

21R

211

3.13

”3

Yes

25 G

PH

26 G

PH

150P

SI

105

Wat

ts45

GP

H

21R

221

3.13

”3

Yes

21 G

PH

26 G

PH

300P

SI

195

Wat

ts45

GP

H

Rec

om

men

ded

Max

. F

ire

Siz

e

1R M

od

els:

Sin

gle

Sta

ge

1725

RP

M

21R

Mo

del

s:S

ing

le S

tag

e,34

50 R

PM

Page 38: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

33

31R

121

3.13

”4

Yes

4 G

PH

9 G

PH

300

PS

I90

Wat

ts20

GP

H

41R

221

3.13

”14

No

18 G

PH

22 G

PH

300P

SI

160

Wat

ts40

GP

H41

R22

13.

13”

4Y

es23

GP

H28

GP

H30

0PS

I22

5 W

atts

55 G

PH

*To

Con

vert

to h

orse

pow

er,

mul

tiply

wat

ts X

.001

3410

31R

Mo

del

s:S

ing

le S

tag

e14

25 R

PM

41R

Mo

del

s:S

ing

le S

tag

e,28

50 R

PM

Page 39: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

34

SE

LE

CT

ION

TA

BL

E —

TW

O-S

TA

GE

Max

imu

mV

aria

ble

No

zzle

&W

atta

ge

Su

ctio

nD

im “

X”

Slo

ttin

gN

ozz

leR

ated

Req

uir

emen

tG

ear

Mo

del

Typ

eS

ee p

g. 3

4C

od

eC

uto

ff@

Rat

ed p

si@

100

psi

Pre

ssu

re@

Rat

ed p

siC

apac

ity

2R11

13.

75”

1Y

es5

GP

H8

GP

H15

0PS

I75

Wat

ts35

GP

H3

10 G

PH

12 G

PH

2R12

13.

75”

3Y

es7

GP

H12

GP

H30

0 P

SI

125

Wat

ts35

GP

H

2R12

23.

75”

3Y

es12

GP

H15

GP

H30

0 P

SI

145

Wat

ts50

GP

H

2R18

13.

75”

4N

o 15

GP

H—

80 P

SI

55 W

atts

35 G

PH

2R16

23.

75”

5Y

es7

GP

H9

GP

H12

5 P

SI

85 W

atts

50 G

PH

2R21

34.

25”

3Y

es26

GP

H27

GP

H15

0PS

I13

0 W

atts

70 G

PH

13,1

4N

o29

GP

H30

GP

H

2R22

34.

25”

3Y

es20

GP

H27

GP

H30

0PS

I21

0 W

atts

70 G

PH

13,1

4N

o23

GP

H30

GP

H

Rec

om

men

ded

Max

. F

ire

Siz

e

2R M

od

els:

Two

Sta

ge

1725

RP

M

Page 40: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

35

2R22

34.

25”

4N

o30

GP

H—

20 P

SI

60 W

atts

70 G

PH

2R25

34.

25”

14N

o30

GP

H30

GP

H10

0 P

SI

100

Wat

ts70

GP

H2R

283

4.25

”4

No

30 G

PH

—80

PS

I90

Wat

ts70

GP

H2R

343

4.25

”13

No

34 G

PH

—45

PS

I70

Wat

ts70

GP

H2R

616

5.75

”13

, 14

No

62 G

PH

66 G

PH

150

PS

I24

5 W

atts

125

GP

H2R

626

5.75

”14

Np

50 G

PH

66 G

PH

300

PS

I41

0 W

atts

125

GP

H2R

636

5.75

”4

No

72 G

PH

—20

PS

I10

5 W

atts

125

GP

H2R

656

5.75

”14

No

66 G

PH

66 G

PH

100

PS

I19

5 W

atts

125

GP

H2R

686

5.75

”4

No

65 G

PH

—80

PS

I17

5 W

atts

125

GP

H2R

618

5.75

”14

No

75 G

PH

80 G

PH

150

PS

I32

5 W

atts

125

GP

H2R

628

5.75

”14

No

60 G

PH

80 G

PH

300

PS

I53

5 W

atts

125

GP

H

*To

Con

vert

to h

orse

pow

er,

mul

tiply

wat

ts X

.001

3410

Page 41: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

36

SE

LE

CT

ION

TA

BL

E —

TW

O-S

TA

GE

(C

ON

T.)

Max

imu

mV

aria

ble

No

zzle

&W

atta

ge*

Su

ctio

nD

im “

X”

Slo

ttin

gN

ozz

leR

ated

Req

uir

emen

tG

ear

Mo

del

Typ

eS

ee p

g. 3

4C

od

eC

uto

ff@

Rat

ed p

si@

100

psi

Pre

ssu

re@

Rat

ed p

siC

apac

ity

22R

210

3.75

”3

Yes

15 G

PH

15 G

PH

150

PS

I90

Wat

ts45

GP

H

22R

220

3.75

”3

Yes

12 G

PH

15 G

PH

300

PS

I14

5 W

atts

45 G

PH

14N

o14

GP

H15

GP

H

22R

250

3.75

”5

Yes

5 G

PH

5 G

PH

100

PS

I70

Wat

ts45

GP

H

22R

211

3.75

”3,

4Y

es25

GP

H26

GP

H15

0 P

SI

130

Wat

ts70

GP

H14

No

26 G

PH

27 G

PH

22R

221

3.75

”3

Yes

21 G

PH

26 G

PH

300

PS

I22

0 W

atts

70 G

PH

14N

o23

GP

H27

GP

H22

R32

24.

25”

14N

o34

GP

H40

GP

H30

0 P

SI

300

Wat

ts10

5 G

PH

22R

613

4.75

”13

No

63 G

PH

65 G

PH

150

PS

I26

0 W

atts

135

GP

H22

R62

34.

75”

14N

o56

GP

H65

GP

H30

0 P

SI

425

Wat

ts13

5 G

PH

Rec

om

men

ded

Max

. F

ire

Siz

e

22R

Mo

del

s:Tw

o S

tag

e34

50 R

PM

Page 42: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

37

32R

111

3.75

”3

Yes

8 G

PH

9 G

PH

150

PS

I65

Wat

ts30

GP

H32

R12

13.

75”

3,4

Yes

4 G

PH

9 G

PH

300

PS

I10

5 W

atts

30 G

PH

32R

213

4.25

”3

Yes

23 G

PH

25 G

PH

150

PS

I11

5 W

atts

60 G

PH

32R

223

4.25

”4

Yes

14 G

PH

25 G

PH

300

PS

I18

0 W

atts

60 G

PH

32R

626

5.75

”14

No

36 G

PH

51 G

PH

300

PS

I34

5 W

atts

105

GP

H42

R12

03.

75”

4Y

es9

GP

H13

GP

H30

0 P

SI

120

Wat

ts40

GP

H42

R21

13.

75”

3Y

es20

GP

H21

GP

H15

0 P

SI

110

Wat

ts60

GP

H42

R22

13.

75”

3,4

Yes

17 G

PH

21 G

PH

300

PS

I18

0 W

atts

60 G

PH

42R

613

4.75

”14

No

47 G

PH

48 G

PH

150

PS

I22

0 W

atts

110

GP

H42

R62

34.

75”

14N

o44

GP

H48

GP

H30

0 P

SI

360

Wat

ts11

0 G

PH

42R

624

4.75

14N

o65

GP

H74

GP

H30

0 P

SI

42R

626

5.75

14N

o72

GP

H84

GP

H30

0 P

SI

NO

TE

S:

Oil

burn

er n

ozzl

es a

re r

ated

at 1

00 p

si.

Any

incr

ease

in fu

el u

nit

pres

sure

ove

r 10

0 ps

i will

incr

ease

the

fire

size

abo

ve n

ozz

le r

atin

g. T

o as

sure

com

plia

nce

with

NF

PA

's B

ulle

tin 3

1, “

Inst

alla

tion

of O

il B

urni

ng E

quip

men

t,” fu

el u

nit p

ress

ure

shou

ld n

ot e

xcee

d 3

psig

.

*To

Con

vert

to h

orse

pow

er,

mul

tiply

wat

ts X

.001

3410

32R

Mo

del

s:Tw

o S

tag

e14

25 R

PM

42R

Mo

del

s:Tw

o S

tag

e28

50 R

PM

Page 43: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

38

R SERIES FUEL UNITS — CODE ANALYSIS

A F1R - Single Stage -1725 RPM Bypass Plug Access

21R - Single Stage -3450 RPM -Left hand inlet (from front)2R - Two Stage -1725 RPM

22R - Two Stage -3450 RPM31R - Single Stage -1425 RPM G41R - Single Stage -2850 RPM Design Series32R - Two Stage -1425 RPM Shaft Seal Type42R - Two Stage -2850 RPM Face Lip

BNumber of Filter Sections1 thru 6

CMax Rated Pressure (PSI)

Max. FactoryCode Pres. Set At

1 150 PSI 100 PSI2 300 PSI 100 PSI3 20 PSI 10 PSI4 45 PSI 40 PSI5 100 PSI 100 PSI6 125 PSI 100 PSI8 80 PSI 20 PSI

DPressure Gear Size 0 thru 8

ERotation and Porting-As viewed from Shaft EndA Clockwise Nozzle Port LeftB CCW Nozzle Port RightC CCW Nozzle Port LeftD CW Nozzle Port Right

Rotation and Nozzle Location

R Series Fuel Units are available in standard C Style models(counterclockwise rotation, nozzle port on left, as viewed fromshaft end) or D Style models (clockwise rotation, nozzle port onright, as viewed from shaft end).

Some special models are available with A Style porting (clock-wise rotation, nozzle port on left) and B Style porting (counter-clockwise rotation, nozz le port on right) Consult SalesDepartment for availability.

FUEL UNITS (CROSS REFERENCE)Webster Model No. Suntec Model No.21R150D*4A5 JA2BB-10021R150D*4A5 JA2BB-30021R150D*4A5 JB2BB-10021R150D*4A5 JJ2BB-30021R221D-4C3 J2BA-10021 R221D-4C3 J2BB-1001R162D*4BK5/21 R150D*4A5 J2BB-300

1 4 1 stage or 2 stagew/suction gearsame size aspressure gear.

3 5 2 stage w/suctiongear one size largerthan pressure gear.

HSpecial CustomerModifications

JNozzle Outlet Type andBypass Condition. Final digiteven - Factory set for 2-pipeoperation. Final digit odd -Factory set for one pipeoperation.

• Pumps ending in 3 internalcut-off

• Pumps ending in 14 nointernal cut-off

TYPICAL CODE— IR I I I D — I A 3

A B C D E F G H J

Page 44: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

39

FUEL-UNITS (CROSS REFERENCE) (Cont.)Webster Model No. Suntec Model No.21R221C-4C3 J2BC-10021R221D-4C3 J3BA-10021R221D-4C3 J3BA-B10021R221D-4C3 J3BB-10021R221D-4C3 J3BB-20021R221C-4C3 J3BC-10021R221C-4C3 J3BC-20021R221C-4C3 J3BC-17921R221C-4C3 J3BC-40821R221C-4C3 J3BD-1001R122D-4C3 (1725only) J4PB-1001R122C-4C3 (1725only) J5BC-313H1R122C-4C3 (1725only) J5BC-D31722R220D-5C3 HA2BB-10022R220D-5C3 HA2BB-30022R211D-5C3 H2BB-10022R211D-5C3 H2BB-30022R211C-5C3 H2BC-41222R211D-5C3 H2PB-10022R211D-5C3 H3BA-10022R211D-5C3 H3BA-20022R211D-5C3 H3BA-B200H22R211D-5C3 H3BB-10022R211D-5C3 H3BB-20022R211C-5C3 H3BC-10022R221C-5C3 H3BC-C200H22R211C-5C3 HBBD-20022R211D-5C3 H3PA-10022R221D-5C14 H3PAN-C150H22R221D-5C3 H3PB-B10022R221D-5C14 H3PBN-C254H22R322D-5C14 H4PA-20022R221D-5C3 H4PAN-C131H22R221D-5C14 H4PAN-C251H22R221C-5C3 H4PC-C200H22R623D-5C14 H5PA-20022R623D-5C14 H5PB-1002R121D-5C3 H6PA-C10022R623D-5C14 H6PA-20022R623C-5C14 H6PC-C200H22R623C-5C14 H6PC-C253H2R628C-4C14 H8KCN-C2002R618D-4C14 H8PB-200

Page 45: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

40

Dim

ensi

on

sT

he g

ener

al d

imen

sion

s in

dica

ted

appl

y to

bot

h 1

R M

odel

s(s

ingl

e-st

age)

and

2R

Mod

els

(tw

o-st

age)

. Ref

er to

Sel

ectio

nTa

ble

for

varia

ble

dim

ensi

on X

.

Dra

win

g sh

ows

nozz

le a

nd g

auge

por

t loc

atio

ns fo

r D

Sty

leun

its.

C S

tyle

uni

ts a

re th

e op

posi

te o

f tha

t pic

ture

d.

Page 46: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

41

INS

TAL

LA

TIO

N D

ATA

R S

erie

s un

its m

ay b

e us

ed in

one

- or

two-

pipe

inst

alla

tions

. Tw

o-pi

peop

erat

ion

is r

ecom

men

ded

for

all h

igh

capa

city

uni

ts.

A y

ello

w ta

g is

atta

ched

to

units

that

are

fact

ory

set f

or tw

o-pi

pe in

stal

latio

n.

NO

TE

:In

let

port

s #1

and

#2,

and

ret

urn

port

#2

are

3/8”

pip

e th

read

on

high

cap

acity

uni

ts. (

2R6-

8 S

erie

s.)

Uni

t sh

own

at th

e rig

ht h

as a

left

side

by-

pass

plu

g ac

cess

, (-)

in th

esa

les

code

. (*)

in th

e co

de d

esig

nate

s rig

ht h

and

acce

ss a

s sh

own

belo

w.

To V

ent

Pum

p: A

ttach

1/4

” ID

pla

stic

tube

. U

se 3

/8”

wre

nch

to o

pen

vent

1/8

turn

max

imum

.

For

Use

as

Gau

ge P

ort:

Rem

ove

inse

rtto

inst

all 1

/8”

pipe

thre

aded

gag

e

Rem

ove

plug

to in

stal

l1/

4” p

ipe

thre

aded

gau

ge.

Noz

zle

Por

t: 1/

8” p

ipe

thre

ad (

1/4”

pip

e th

read

ifpu

mp

code

end

s in

13

or 1

4

Inle

t P

ort #

21/

4” P

ipe

Thr

ead

“Ins

ert

- (B

ypas

s P

lug

1/8

pipe

thre

ad)“

P/N

295

33-3

5

Ret

urn

Por

t #2

1/4”

Pip

e T

hrea

d,us

e as

ret

urn

on

two

pipe

inst

alla

tion

Ret

urn

Por

t #1:

1/4

” pi

pe th

read

,us

ed a

s re

turn

on

two

pipe

inst

alla

tion. P

ort

near

est p

ress

ure

adju

stin

g sc

rew

is

neve

r us

ed

Inle

t P

ort #

11/

4” P

ipe

Thr

ead

To A

djus

t P

ress

ure:

Rem

ove

cove

r sc

rew

.In

sert

1/8

Alle

nw

renc

h. T

urn

coun

ter-

cloc

kwis

e to

bel

owpr

essu

re d

esire

d.T

urn

cloc

kwis

e to

set

to d

esire

d pr

essu

re.

Kee

p co

ver

scre

wtig

ht e

xcep

t whe

nad

just

ing

pres

sure

.

Ret

urn

Por

t #2:

1/4

” pi

pe th

read

, use

das

ret

urn

on tw

o pi

pe in

stal

latio

n

Inle

t P

ort #

1: 1

/4”

pipe

thr

ead

Inle

t P

ort #

2: 1

/4”

pipe

BO

DY

ST

YL

E D

CL

OC

KW

ISE

RO

TAT

ION

BO

DY

ST

YL

E C

CO

UN

TE

RC

LO

CK

WIS

E R

OTA

TIO

N (

CC

W)

OP

PO

SIT

E O

F T

HA

T P

ICT

UR

ED

Page 47: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

42

One-Pipe Installation

Recommended only when bottom of tank is above fuelunit, unless pump code ends in 15.

1. Remove BYPASS PLUG if installed, through applica-ble INLET PORT.

2. Connect inlet line to preferred INLET PORT andNOZZLE PORT to NOZZLE SYSTEM.

3. Plug all unused ports securely.

4. Start burner and bleed all air from the system byopening VENT PLUG. Close VENT securely when oilflow in tube is clear , if pump is equipped with specialvent plug. Secure GAUGE PORT PLUG on units not soequipped when oil appears leaking out.

Two-Pipe Installation

1. Insert BYPASS PLUG if not installed, through appli-cable INLET PORT.

2. Connect inlet line to preferred INLET PORT andNOZZLE PORT to NOZZLE SYSTEM

3. Connect return line to preferred RETURN POR T.

4. Plug all unused ports securely.

5. Start burner. Two-stage pumps will self-vent. If singlestage and code ends in3 or 4, bleed all air from systemby opening VENT PLUG. Close VENT securely whenoil flow in tube is clear, if pump is equipped with specialvent plug. Secure GAUGE PORT PLUG on units not soequipped when oil appears leaking out.

Mounting for One-Pipe Systems

Gravity Feed Systems (Diagram A)—Fuel-units may bemounted in any position including shaft up and shaftdown. See Positions 1 through 4.

Non-Gravity Feed Systems (Diagram B) — R SeriesFuel Units may only be mounted upright, Position 1; orrotated 90° with nozzle down, Position 2. Other mount-ing positions are not recommended.

DIAGRAM A - ONE PIPE, GRAVITY FEED SYSTEM

Page 48: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

43

Mounting for Two-Pipe Systems

Fuel units may be mounted in any position includingshaft up and shaft down. See Positions 1 through 4.

Illustrations show port locations for C Style units (coun-terclockwise rotation); D Style units (clockwise rotation)are the opposite of that pictured.

Installation diagrams shown for reference only .Compliance to applicable codes is the responsibility ofinstaller.

POSITION 1Upright,Nozzle Right:

All One pipe orTwo Pipe Systems

POSITION 2Rotated 90°Nozzle Down:

All One Pipe orTwo Pipe Systems

POSITION 3Rotated 180°Nozzle Left:

All Two Pipe Systems,or One Pipe GravityFeed Systems Only

DIAGRAM B - ONE PIPENON-GRAVITY FEED SYSTEM

Page 49: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

44

Replacing A Style and B Style Units

Discontinued A Style and B Style R Series fuel unitscan be replaced with minimal changes in most installa-tions. Fuel unit model code numbers and rotationarrows are stamped on the top of the body casting.

In two-pipe systems and in one-pipe, gravity feed sys-tems, current C Style and D Style units can be mount-ed in any position to facilitate easiest piping.

In one-pipe,non-gravity feed systems (where themounting positions are limited), an extra length of pipeor tubing must be connected to the nozzle line to reachthe fuel unit nozzle port. See previous page for permit-ted mounting positions.

Preferred installation calls for use of flare tube fittingson al I connections. Be certain all plugs and connec-tions are secure and leak-tight.

POSITION 4Rotated 270°Nozzle Up:

All Two Pipe Systems,or One Pipe GravityFeed Systems Only

Body StylesA (CW) & C (CCW)(LH Nozzle, Viewed

From Shaft End)

Body StylesB (CCW) & D (CW)(RH Nozzle, Viewed

From Shaft End)

To Vent Pump:Loosen Gauge Port Plug

For Use as Gauge Port:Remove Plug to install

1/4” Pipe Threaded Gauge

Pumps WithoutSpecial Vent Fitting

Page 50: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

45

Typical Replacement Installations

Replace A Style units (clockwise rotation, nozzle port onleft, as viewed from shaft end) with D Style units (clock-wise rotation, nozzle port on right, as viewed from shaftend).

Standard A Style Installation:One or Two Pipe System

Replacement with D style,Rotated 180°: One Pipe, Gravity

Feed System: or Two Pipe System

Replacement with D style,Nozzle Line Extended: One Pipe,

Non-Gravity Feed System

Page 51: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

46

Replace B Style units (counterclockwise rotation, noz-zle port on right, as viewed from shaft end) with C Styleunits (counterclockwise rotation, nozzle port on left, asviewed from shaft end).

Standard B Style Installation:One or Two Pipe System

Replacement with C style,Rotated 180°: One Pipe, Gravity

Feed System: or Two Pipe System

Replacement with C style,Nozzle Line Extended: One Pipe,

Non-Gravity Feed System

Page 52: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

47

IMPORTANT: Do not loosen or try to tighten any pumpplugs not to be used in the installation. NON-HARDEN-ING OIL PIPE DOPE IS RECOMMENDED for use onthe threads of all fittings. Paste must be used with careto prevent deposits on critical internal areas of thepump damage. Do not use teflon tape. EVIDENCE OFTEFLON TAPE USE WILL BE CAUSE TO VOID WAR-RANTY.

Installation Notes:

If the pump doesn't work, check for air leaks.

If you're experiencing the following problems;poor cutoff, noisy operation, erratic fire, check forair leaks.

❏ Return line must be submerged

❏ Check all fittings

❏ Check all joints

❏ Check optional inlet plugs

❏ DO NOT use compression fittings

90% of start-up problems are due to air leaks in the suc-tion line . . . so check ✔ and double check ✔ ✔ for airleaks.

“Fuel unit inlet pressures should not exceed 3 psig inorder to comply with National Fire ProtectionAssociation's Bulletin 31.”

Nozzle port pressure at cutof f is not less than 80% ofset pressure unless unit has blank nozzle or pump codeends in 13 or 14 (no cutof f).

To assure maximum performance, INLET VACUUM,measured at unused INLET PORT, should not exceed10” Hg on single-stage pumps or 15” Hg on two-stagepumps.

Page 53: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

48

1R00 SERIES SINGLE-STAGE TRANSFER PUMPS

BODY STYLE C & D

Rated at capacities up to 66 gph at 100 psi, the 1R00Series features the versatili ty of the R Series design.With 2 inlet ports, 4 discharge ports, and 1 gauge/ventport, the 1R00 Series can fit virtually all installations.

FUEL UNIT SPECIFICATIONS

Single-Stage Transfer Pumps lR00 Series Pumps

Capacities:1R003-4EH—31 gph at 100 psi 1R004-4EH, 4EG—43 gph at 100 psi1R006-4EH—66 gph at 100 psi.

Pressure:No internal pressure regulator.

Speed: Rated at 1725 rpm.

Rotation:D Style—Clockwise when viewed from shaft end.C Style—Counterclockwise when viewed from shaft end.

Porting:1/4” NPTF: gauge/vent port, 2 inlets and 4 dischargeports.

Shaft:7/16” diameter, key drive.EH units have 1-7/8” shaft extension from mountingface. EG unit has 3-1/8” shaft extension from mountingface with outboard ball bearing.

Seal: Mounting:Double lip type. Hub or two bolt flange mount.

Filter:No internal filter. External filter recommended.

Maximum Inlet Vacuum:10” Hg.

U.L. Listed:To assure compliance with National Fire ProtectionAssociation's Bulletin 31, “Installation of Oil BurningEquipment,” fuel unit inlet pressure should not exceed3 psig.

Operation

The 1R00 Series pumps do not incorporate an internalregulating valve or filter. They are intended for transferuse up to 100 psi and must not be operated withblocked outlet. Use one-pipe installation only and donot remove bypass plug.For maximum performance inlet vacuum, when meas-ured at unused inlet port, should not exceed 10” Hg.

Page 54: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

49

R SERIES FUEL UNITS — CODE ANALYSIS

A F1R - Single Stage -1725 RPM Bypass Plug Access

21R - Single Stage -3450 RPM * Right hand inlet 2R - Two Stage -1725 RPM (from front cover)

22R - Two Stage -3450 RPM -Left hand inlet (from front)31R - Single Stage -1425 RPM G41R - Single Stage -2850 RPM Design Series32R - Two Stage -1425 RPM Shaft Seal Type42R - Two Stage -2850 RPM Face Lip

BNumber of Filter Sections1 thru 6

CMax Rated Pressure (PSI)

Max FactoryCode Pres Set At

1 150 PSI 100 PSI2 300 PSI 100 PSI3 20 PSI 10 PSI4 45 PSI 40 PSI5 100 PSI 100 PSI6 125 PSI 100 PSI8 80 PSI 20 PSI

DPressure Gear Size 0 thru 8

ERotation and Porting-As viewed from Shaft EndA Clockwise Nozzle Port LeftB CCW Nozzle Port RightC CCW Nozzle Port LeftD CW Nozzle Port Right

Rotation and Nozzle Location

R Series Fuel Units are available in standard C Style models(counterclockwise rotation, nozzle port on left, as viewed fromshaft end) or D Style models (clockwise rotation, nozzle port onright, as viewed from shaft end).

1 4 1 stage or 2 stagew/suction gearsame size aspressure gear

3 5 2 stage w/suctiongear one size largerthan pressure gear.

HSpecial CustomerModifications

JNozzle Outlet Type andBypass Condition. Final digiteven - Factory set for 2-pipeoperation. Final digit odd -Factory set for one pipeoperation.

TYPICAL CODE— IR I I I D • I A 3

A B C D E F G H J

Do not use less than 3/8” OD tubing for lines. Size pergearset capacity shown below:

SELECTION TABLE

ModelRatings for 100 psi Gearset

No. 2 Fuel Oil Rating Capacity1 R003-4EH 31 gph 48 gph

1R004-4EH, 4EG 43 gph 66 gph1 R006-4EH 66 gph 95 gph

1ROO Series units are rated for 1725 rpm and may behub or flange mounted. Standard EH units have 1-7/8”shaft extension. EG units 3-1/8” shaft extension, plus out-board ball bearing.

Page 55: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

50

Dim

ensi

on

sD

raw

ing

show

s ga

uge

port

loca

tion

for

D S

tyle

uni

ts. C

Sty

le u

nits

are

the

oppo

site

of t

hat p

ictu

red.

Page 56: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

51

BODY STYLE C

“C” ROTATION DIRECTION

Do NotUse

This Port

Discharge Port #11/4” Pipe Thread

Inlet Port #21/4” Pipe Thread

Discharge Port #31/4” Pipe Thread

Inlet Port #11/4” Pipe Thread

DischargePort #4

1/4” Pipe Thread

Discharge Port #2To vent pump loosengauge port plug,or any unuseddischarge port.

For use asgauge portremove plug toinstall 1/4” pipethreaded gauge

BODY STYLE D

“D” ROTATION DIRECTION

OPPOSITE OF THAT PICTURED

(See rotation arrow on top

of pump to confirm shaft

rotation direction)

INSTALLATION DATA

1. Connect preferred inlet to tank through suitable linefilter.

2. Connect preferred discharge port to external regula-tor or distribution system.

3. For initial priming it is desirable to loosen the gaugeport plug or any unused discharge port to bleed air fromthe supply line and pump. Tighten the plug securelywhen oil flows clear.

Failure to prime pump may be due to “dry pump” condi-tions. Remove vent plug and fill pressure cavity slowlyto allow oil to “wet” the gears.

4. Be certain all plugs and connections are secure andleak-tight

Checking for Air Leaks

Be certain all plugs, fittings and joints are secure andairtight. Many problems in fuel unit installations resultfrom air leaks in the suction line.

Measure inlet vacuum during operation at an unusedinlet port. An abnormally low vacuum reading may indicatean air leak. Generally, assume 0.75 inch of vacuum forevery foot of vertical lift, plus frictional tubing losses andother in-line restrictions.

Page 57: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

52

V SERIES HIGH DELIVERY FUEL PUMPS

The V Series is designed to meet the high deliveryrequirements of commercial, industrial, and institutionalsystems with a minimum of mechanical and hydraulicnoise. Single-stage models can provide a firing rate upto 270 gph at up to 10” Hg inlet vacuum. Two-stage fir-ing rates are as high as 205 gph up to 15” Hg inlet vac-uum. Field adjustable integral regulating valves factorypre-set for 100 and 150 psi operation are offered as anoption to meet specific system requirements.

Single Stage

Two Stage

Page 58: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

53

FUEL UNIT INSPECTIONS

Single- and Two-Stage Fuel-Units

V SeriesHigh Capacity Fuel and Transfer Pumps

Capacities:Single-stage units: up to 180 gph with #2 oil, to 270 gphwith 1000 SSU oil.Two-stage units: up to 145 gph with #2 oil, to 205 gphwith 1000 SSU oil

NOTE: See rating table for capacity at specific pres-sure and rpm

Pressure:V02: Rated pressure 300 psi—factory set at 150 psi. V05: Rated pressure 100 psi—factory set at 100 psi. V08: Rated pressure 80 psi—factory set at 20 psi. V00: No internal regulation.

Speeds:1725 or 3450 rpm.

Rotation: D Style—clockwise when viewed from shaft end. C Style—counter clockwise when viewed from shaft end.

Porting:1/4” NPTF: gauge/optional nozzle port, nozzle port.3/8” NPTF: return port, 2 optional inlets.1/2” NPTF: inlet in cover

Shaft:DM Style—7/16” x 3 5” extension from mounting face.DO Style—7/16” x 1.88” extension from mounting face.

Seal:Double lip type.

Mounting:Hub or two bolt flange mount.

Filter:No internal filter. External Line filter recommended.

Maximum Inlet Vacuum:Single-stage units: 10” HgTwo-stage units: 15” Hg

U.L. Listed

Page 59: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

54

SE

LE

CT

ION

TA

BL

EN

OT

E:

Max

. R

ecom

men

ded

Firi

ng R

ates

app

ly a

t 10”

Hg

for

sing

le-s

tage

uni

ts a

nd 1

5” H

g fo

r tw

o-st

age

units

Sh

aft

1725

3450

1725

3450

1725

3450

1725

3450

1725

3450

V05

& V

02 S

erie

s S

ing

le-S

tag

e F

uel

Pu

mp

s (w

ith

Inte

rnal

Reg

ula

tio

ns)

V05

2_-4

D_2

040

7565

135

6513

5.2

5.3

3.2

5.7

55.

13V

056_

-4D

_20

130

—19

0—

190

—.5

0—

.75

—5.

13V

022_

-4D

_20

2060

5012

050

120

.50

.75

.50

1.0

5.13

V02

3_-4

D_2

040

105

8018

580

185

.50

1.00

.50

1.5

5.13

V02

4_-4

D_2

060

140

110

240

110

240

.75

1.5

.75

2.0

5.13

V02

6_-4

D_2

095

—15

5—

155

—1.

0—

1.0

—5.

13V

028_

-4D

_20

115

—19

0—

190

—1.

5—

2.0

—5.

672V

022_

-5D

_20

2060

5012

010

020

5.5

01.

0.5

01.

55.

672V

023_

-5D

_20

4010

580

185

140

270

.75

1.5

.75

2.0

6.17

2V02

4_-5

D_2

060

—11

0—

200

—.7

5—

1.0

—6.

712V

026_

-5D

_20

95—

155

—25

0—

1.5

—1.

5—

7.75

Max

. R

eco

md

.F

irin

gR

ate

gp

h34

SS

U

Max

. R

eco

md

.F

irin

gR

ate

gp

h10

00S

SU

Inle

t L

ine

Siz

ing

Gea

r S

et C

apac

ity

gp

h34

SS

U t

hru

1000

SS

U

Rec

om

men

ded

Mo

tor

h.p

.34

SS

U

100

0 S

SU

Dim

.A

100

psi

Rat

ings

300

psi

Rat

ings

300

psi

Rat

ings

Page 60: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

55

V00

Ser

ies

Sin

gle

-Sta

ge

tran

sfer

(w

ith

no

inte

rnal

Reg

ula

tio

n

V00

2_-4

D_

4585

7014

070

140

.25

.25

.25

.50

5.13

V00

3_-4

D_

7014

010

020

510

020

5.2

5.2

5.2

5.7

55.

13V

004_

-4D

_95

175

140

270

140

270

.25

.25

.25

.75

5.13

V00

6_-4

D_

145

—20

0—

200

—.2

5—

.50

—5.

13V

08 S

erie

s S

ing

le-S

tag

e T

ran

sfer

Pu

mp

s (w

ith

Inte

rnal

Reg

ula

tio

n)

V08

6_-4

D_2

013

5—

190

—25

0—

.33

—.7

5—

7.75

2V00

Ser

ies

Tw

o-S

tag

e Tr

ansf

er P

um

ps

(wit

h n

o In

tern

al R

egu

lati

on

)

2V00

6_-5

D_

145

—20

0—

250

—.3

3—

.75

—7.

75

2V08

Ser

ies

Su

pp

ly P

um

ps

(wit

h In

tern

al R

egu

lati

on

)

2V08

6_-5

D_4

135

—19

0—

250

—.5

0—

1.0

—7.

75

*O

pera

ting

pres

sure

to 3

00 p

si p

erm

issi

ble

(usi

ng e

xter

nal r

egul

atin

g va

lve)

V00

Ser

ies

gph

and

hp r

atin

gs a

t 10

0 ps

i sam

e as

V05

rat

ings

abo

ve.

V00

Ser

ies

gph

and

hp r

atin

gs a

t 30

0 ps

i sam

e as

V02

rat

ings

abo

ve.

**O

pera

ting

pres

sure

to 3

00 p

si p

erm

issi

ble

(usi

ng e

xter

nal r

egul

atin

g va

lve)

2V00

Ser

ies

gph

and

hp r

atin

gs a

t 30

0 ps

i sam

e as

V02

rat

ings

abo

ve.

Ava

ilabl

e in

CW

and

CC

W r

otat

ion.

20 p

siR

atin

gs*

80 p

siR

atin

gs*

20 p

siR

atin

gs**

80 p

siR

atin

gs**

Page 61: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

56

APump SeriesVO—Single-Stage2VO—Two-Stage

BRated Typ. Adj.

Pressure Pressure RangeCode (psi) (psi)

0 No Valve —5 100 85-1202 300 125-3308 80 15-85

CGear Size Code Nom. Thickness

2 1/43 3/84 1/26 3/48 1

DBodyStyle Rotation Nozzle

C CCW LeftD CW Right

NOTE: Nozzle location andshaft rotation determinedviewing unit from shaft end.

E.No. Design Series1 Initial Design3 2-Stage, Inlet Gear One Size

Larger than Pressure Gear4 Single-Stage, Seal Pressed in Body5 Same as 3 Ex. Seal Pressed/Body

F. GCust. Code Shaft Ext. Pump Operation

DM 3-1/2 V-Guide, One Slot, No CutoffDO 1-7/8 No Number for Transfer Pumps

Rotation and Nozzle Location

V Series Fuel-Units are available in standard C StyleModels (counterclockwise rotation, nozzle port on left,as viewed from shaft end) or D Style Models (clockwiserotation, nozzle port on right, as viewed from shaft end.

V SERIES CODE ANALYSIS

HARDENED GEARS —H J71—MFG. DATE CODE

V0 2 6 C 1 00 30

A B C D E F GROTATION

Page 62: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

57

C S

tyle

Sho

wn

Cou

nter

cloc

kwis

eR

otat

ion

Bod

y S

tyle

DC

lock

wis

e R

otat

ion

Opp

osite

of t

hat P

ictu

red

C =

MO

TO

R L

EN

GT

HD

= O

VE

RA

LL

DIM

EN

SIO

NA

or

E =

V O

R R

PU

MP

DIM

EN

SIO

N

Page 63: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

58

INSTALLATION DATA

V Series pumps are shipped from the factory set fortwo-pipe operation. They are not recommended for usein one-pipe systems (except series V00, see Note 1).

IMPORTANT: Do not loosen or try to tighten any pumpplugs not to be used in the installation. NON-HARDEN-ING OIL PIPE DOPE IS RECOMMENDED for use onthe threads of all fittings. Teflon tapes or paste must beused with care to prevent depositing tape pieces orfibers into critical internal areas of the pump. Reducedtorques must be used with teflon materials to avoidthread or casting damage. EVIDENCE OF TEFLONMATERIAL IN INTERNAL AREAS OF THE FUEL-UNITWILL BE CAUSE TO VOID WARRANTY.

Installation

1. Connect inlet line to preferred INLET PORT. Use ofinlet in cover is recommended for minimum inlet vacu-um loss. Connect nozzle line to nozzle port.

2. Connect return line to preferred RETURN POR Texcept on V00 pumps. Use of bottom return is recom-mended to minimize back pressure. Top return port notrecommended for oil heavier than #2.

3. Plug all unused ports securely.

4. Start burner. Two-stage and most one-stage pumpswill self-vent. V00 with shut-off valve in nozzle line mayhave to be vented manually by loosening GAGE PORTplug. Tighten plug securely when oil flows clear.

Installation Notes:

“Fuel unit inlet pressures should not exceed 3 psig inorder to comply with National Fire ProtectionAssociation's Bulletin 31.”

To assure maximum performance, INLET VACUUM,measured at unused INLET PORT, should not exceed10” Hg on single-stage pumps or 15” Hg on two-stagepumps.

NOTE: Max Recommended Firing Rates apply to 10”Hg for single-stage units and 15” Hg for two-stage units.

Page 64: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

59

Page 65: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

60

B SERIES FUEL OIL TRANSFER PUMPS

B Series transfer pumps are designed to provide ef fi-cient pumping of #1 to #6 fuel oils in capacities from 80to 290 gallons per hour, at pressures up to 500 psi (#1to 300 psi). With high-density gray iron body construc-tion, heat-treated alloy steel gears and shafts, andheavy-duty needle bearings, B Series transfer pumpsoffer superior durability and high mechanical ef ficiencyDouble lip V iton seals, are standard. B Series pumpsare available in—clockwise (right hand) or counter-clockwise (left hand) rotations. All B Series transferpumps are U.L. listed.

Page 66: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

61

SPECIFICATIONS

B SeriesFuel Oil Transfer Pumps

Capacity:80 to 290 gph at 1725 rpm and 100 psi (#1 to #6 fueloil). 160 to 520 gph at 3600 rpm and 100 psi (#1 to #6fuel oil).

Pressure:#4 to #6 fuel oils up to 500 psi, #2 fuel to 350 psi.

Speed:For direct or belt drive application up to 3600 rpm.

Rotation: Clockwise rotation viewed from shaft end.

Porting:1/2” NPTF: side inlet and side outlet ports. (18B, 37B,47B)3/4” NPTF: Side inlet and side outlet ports (59B)

Shaft:Standard: .50 OD, 1.00 flat length, 1.88” extensionfrom mounting face.

Seal:Standard—double lip type, Viton

Mounting:Hub, 2-1/8”, with 8 standard hub spots.

Filter:No internal filter. External filter recommended.

Maximum Inlet Vacuum:10” HgU.L. Listed

SELECTION TABLEPump Capacity at 100 psiwith #2 Fuel Oil at 75°F.

1750 rpm

Pump Input

Model* hp gph

18B .14 80

37B .21 155

47B .30 220

59B .45 290

Page 67: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

62

PSI300

200

100

25

25300

PSI300

200

100

25

25300

18B

37B

Page 68: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

63

PSI300

200

100

25

25100300

PSI300

200

100

25

25300

47B

59B

Page 69: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

64

INSTALLATION AND DIMENSIONAL DATA

Single-Rotation Models

Connect discharge and suction lines to NPTF portsdepending on desired direction of shaft rotation.Direction of shaft rotation is always toward dischargeport.

CAUTION: Do not attempt to operate pump with dis-charge port blocked.

Correct shaft rotation is shown by arrow stamped onback of pump. Do not attempt to operate pump in oppo-site direction. Use an external regulating valve in discharge line ifpressure regulation is necessary.

Installation Notes:

“Fuel unit inlet pressure should not exceed 3 psig inorder to comply with National Fire ProtectionAssociation's Bulletin 31“

To assure maximum performance, INLET VACUUM,measured at unused INLET PORT, should not exceed10” Hg on single-stage pumps.

CODE DIM “A” DIM “B”

18B 3.36 2.66

37B 3.71 3.02

47B 4.05 2.13

59B 4.40 2.30

2.123

1.00

1.35

500

1.87

.44

.5000

A

B

Page 70: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

65

SUPPLY PUMP UNITSWebster can of fer pump sets in a variety of combina-tions. Webster will mount any of our low speed pumpheads to any motor type. Available in simplex, duplexmanual and duplex automatic configurations. See thecode breakdown below.

Sup

ply

Pum

p an

d M

otor

Cod

e B

reak

dow

n

Exa

mpl

es:

SP

M-5

0AT

2R21

3 or

SP

MB

-50A

T59

BR

or

SP

MV

-100

BT

086K

-DA

Bas

ic P

refix

Sup

ply

Pum

p &

Mot

or

SP

M

Pum

p H

ead

Ser

ies

No

Lette

r-Sta

ndar

d

B-V

-No

Lette

r

Das

hM

otor

HP

.25=

1/4

hp

500=

5 hp

.25

- 50

0

Mot

or P

hase

Vol

tage

A=

1 ph

ase

B=

3 P

hase

X=

Spe

cial

Vol

tage

50 o

r 60

cy.

A,

B o

r X

Mot

orE

nclo

sure

TE

FC

, O

PD

PE

Exp

losi

onP

roof

T, O

or

E

Das

hW

ebst

er

Pum

pH

ead

P/N

Pre

fix

Pum

p #

No

Lette

r or

Bla

nk =

Sim

plex

DA

- D

uple

xA

utom

atic

DM

- D

uple

x M

anua

l

Bla

nk,

DA

or

DM

Page 71: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

66

C = Motor LengthD = Overall DimensionA or E = V or R Pump Dimension

SPM with a “V” or “R” Series Pump HeadSINGLE SUPPLY UNIT using a 56C Frame Motor

C S

tyle

Sho

wn

Cou

nter

cloc

kwis

e R

otat

ion

Bod

y S

tyle

DC

lock

wis

e R

otat

ion

Opp

osite

of t

hat P

ictu

red

Page 72: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

67

SUPPLY PUMP UNITSGENERAL INFORMATION

Locating Units

Install transfer/supply units in a clean, dry , well-ventilatedlocation as close to the storage tank as possible. Closeinstallation will minimize required vacuum and will allowsmallest diameter piping to be used while assuring an ade-quate supply of oil.

The units can be mounted in any position. Preferred posi-tion for convenient line connect ions is horizontal with footmounts down.

Filter or Strainer

A reliable in-line filter or strainer is recommendedbetween the tank and the supply pump. Filter or strain-er capacity must at least equal the suction gear capac-ity of the pump to minimize restriction in the suction line.

Oil Safety Valves

Oil safety valves, mounted close to the burner assembly, iso-late burner fuel pumps from supply line pressures. The oilsafety valve relieves pressure strain on burner pump seals,and prevents tank siphoning and spilling caused by acci-dental line breaks. To assure compliance with National FireProtection Association's Bulletin 31, “Installation of OilBurning Equipment,” burner fuel pump inlet pressure shouldnot exceed 3 psig. The Webster OSV Series valves satisfythis requirement when properly installed.

An optional mesh strainer, rated for maintained system pres-sure, can be installed before each OSV near the burnerassembly to protect the OSV from harmful scale which mayoccur in black iron pipe.

Tee fittings should also be inserted on the supply side ofeach OSV in the system. This will allow a pressure readingto be taken when setting system pressure.

Measuring Inlet Vacuum

When installation is complete,the compound gauge should beused to measure inlet vacuum. For maximum performance, vacuum when measured atunused inlet port duringoperation should not exceed15” Hg on the two-stageSPM supply pumps.

A vacuum reading greaterthan 15” Hg indicates inadequate oilsupply, which could be a result of excessive vertical lift,undersized tubing, a plugged or unders ized filter or strainer,sticking check valves, or a frozen, kinked or otherwiserestricted suction line.

Page 73: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

68

SPM SERIESFEATURES

SPM Series pump/motor units consist of a fuel pumpdirect coupled to a motor . an integral check valve andcombination vacuum/pressure gauge. They aredesigned to supply fuel oil from a central storage tank toremote heating units or auxiliary tanks.

SPM pumping units were developed to supply fuel oil toone or more overhead furnaces, day tanks, or for under-ground central distribution. Four pump/motor sizes areavailable, with capacities of 15, 30, 65 and 135 gph (57,114, 245 and 510 1/hr).1/6 hp,1/4 hp and 1/3 hp (124 W,186 W and 248 W) motors are split phase available foreither 115 or 230 volt operation. 1/2 hp (373 W) motorsare capacitor start—induction run, totally enclosed withdual 115/230 volt windings. The units are shipped com-pletely assembled and include a gauge and check valve.All are 60 cycle, 1750 rpm, continuous duty.

An abnormally low vacuum reading may indicate an air leak inthe suction line, valves, or fittings. Generally , assume 0.75” ofvacuum for every foot of vertical lift, plus frictional tubing losses,and other in-line restrictions.

When installing fuel units, to assure compliance with NationalFire Protection Association's Bulletin 31, “Installation of OilBurning Equipment,” fuel unit inlet pressures should not exceed3 psig.

Page 74: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

69

DUPLEX PUMP UNITS SPM SERIESFEATURESThe SPM duplex models consist of two pump/motorassemblies with a pre-piped, common discharge mani-fold. One pump/motor unit operat es continuously, withthe second providing backup service if the main pumpfails. Either automatic (SPM-DA models) or manual(SPM-DM models) controls are available.

The duplex automatic series are designed specificallyfor buildings where a constant supply of oil must beassured ... hospitals, apartment buildings, schools andother commercial/industrial buildings

The DA Series is equipped with a pressure sensingdevice which detects a loss in pressure of the primarypump. If the standby pump is brought into service, analarm sounds which indicates a malfunction in the pri-mary pump.

The electric control circuit on the duplex automaticpump set is equipped with a lead-lag switch to permitmanual alternation of pump to provide even wear oneach pump.

The manually operated duplex pump sets of fer thesame protection as an automat ic except the standbypump must be turned on manually which requires thatmaintenance personnel always be available.

Page 75: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

70

SUPPLY UNIT SPECIFICATIONS

SPM Series Supply Units

Single and Duplex

Capacities:15, 30, 65, and 135 gph

Pressure:Maximum operating pressure to 80 psi or 200' of head.

Motors: All motors are 60 cycle, 1750 rpm, continuous duty, 48Nframe, 1/6, 1/4, 1/3 hp: split phase, 115 or 230 volt oper-ation, 1/2 hp: capacitor start/induction run, TEFC, dual115/230 volt.

Pumps:SPM 15, 30, and 65: uses W ebster “2R” Series pumpunits.SPM 135: uses the Webster ʻ2V” Series pump unit.Webster 2R and 2V are UL listed

Porting:SPM 15, 30, 65:

1/4” NPTF—2 inlets, outlet port and top and bottom returns

SPM 135:1/4” NPTF—outlet port3/8” NPTF—return port, 2 optional inlets.1/2” NPTF—inlet.

Seal: All models—double lip type.

Mounting:All models — four bolt foot mount

Filter:Rotary self cleaning type, except in SPM 135. Use ofexternal line filter recommended.

Valves:Pressure regulating assembly in pump maintains set pressure.Check valve maintains oil in feeder lines for instantstarts.

Gauge:2-1/2” dia., calibrated from 30” vacuum to 100 psi.

Controls: Two Types for Duplex Units Only Duplex automatic withlead-lag switch and alarm. Manual with selector switch.

Maximum Inlet Vacuum:All units—15” Hg

National Fire Protection Association compliancerequires fuel inlet pressure not to exceed 3 psig.

NEMA 1Enclosure

Page 76: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

71

SE

LE

CT

ION

TA

BL

EM

od

els

and

Des

ign

Dat

a T

able

1M

ax F

low

Max

.W

atts

@ m

in.

Max

Flo

wP

um

pM

oto

rM

oto

rH

ead

Val

ve A

dj.

@ 8

0p

si@

80

psi

S

uct

ion

Mo

del

Mo

del

Typ

eV

olt

age

hp

ft*

Ran

ge

psi

gp

hg

ph

Cap

.N

o.

SP

M-1

5-1

Sin

gle

115

SP

M-1

5-2

Sin

gle

230

SP

M-1

5-1-

DA

Dup

lex-

Aut

o.11

51/

620

0'10

to

100

psi

6522

1535

2R18

1C-5

BQ

4S

PM

-15-

2-D

AD

uple

x-A

uto.

230

(351

96-5

)S

PM

-15-

1-D

MD

uple

x-M

an11

5S

PM

-15-

2-D

MD

uple

x-M

an23

0S

PM

-30-

1S

ingl

e11

5S

PM

-30-

2S

ingl

e23

0S

PM

-30-

1-D

AD

uple

x-A

uto

115

1/4

200'

10 t

o 10

0 ps

i95

4530

702R

283C

-5B

Q4

SP

M-3

0-2-

DA

Dup

lex-

Aut

o23

0(3

5196

-6)

SP

M-3

0-1-

DM

Dup

lex-

Man

115

SP

M-3

0-2-

DM

Dup

lex-

Man

230

SP

M-6

5-1

Sin

gle

115

SP

M-6

5-2

Sin

gle

230

Page 77: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

72

SP

M-6

5-1-

DA

Dup

lex-

Aut

o.11

51/

320

0'10

to

100

psi

175

9065

125

2R68

6C-5

BQ

4S

PM

-65-

2-D

AD

uple

x-A

uto.

230

(351

96-7

)S

PM

-65-

1-D

MD

uple

x-M

an11

5S

PM

-65-

2-D

MD

uple

x-M

an23

0S

PM

-135

Sin

gle

Dua

lS

PM

-135

-DA

Dup

lex-

Aut

o.11

51/

220

0'10

to

100

psi

300

157

135

250

2V08

6C-5

D04

SP

M-1

35-D

MD

uple

x-M

an.

230

(351

96-8

)

SP

M P

umps

are

set

at 2

0 ps

i.

*E

quiv

alen

t he

ad e

qual

s ve

rtic

al h

eigh

t fro

m s

uppl

y pu

mp

disc

harg

e to

hig

hest

poi

nt in

sys

tem

, plu

s pr

essu

re d

rop

for

leng

th o

f p

ipin

g ru

n,pl

us a

dditi

onal

loss

es d

ue to

fitti

ngs.

**P

umpi

ng #

2 oi

l (34

SS

UU

). .8

5 S

p. g

r.

Su

pp

ly P

um

p U

nit

Cro

ss R

efer

ence

Web

ster

Mo

del

No

.S

un

tec

Mo

del

No

.S

PM

-15-

1 (1

725

rpm

)—

SP

M-3

0-1

(172

5 rp

m)

BH

-100

0M (

1725

rpm

)S

PM

-30-

1 (1

725

rpm

)B

B-1

020M

(34

50 r

pm)

SP

M-3

0-1

(172

5 rp

m)

BH

-103

0H (

3450

rpm

)S

PM

-65-

1 (1

725

rpm

)B

H-1

001M

(17

25 r

pm)

SP

M-6

5-1

(172

5 rp

m)

BH

-107

0M (

3450

rpm

)S

PM

-135

(17

25 r

pm)

For

hig

her

capa

citie

s, c

onsu

lt fa

ctor

y

Page 78: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

73

INSTALLATION DATA

Compound Gauge0-30” Hg0-100 psi

Check Valve

Discharge Port1/4” Pipe Thread

This PortNever Used

Pressure AdjustingScrew 1/8” Allen

Head Socket UnderSeal Screw

SPM-135 Models

Preferred Cover Inlet1/2” Pipe Thread

Return Port3/8” Pipe Thread

OptionalReturn Port1/4” PipeThread

Inlet Port #21/4” PipeThread

Return Port1/4” PipeThread

Inlet Port #11/4” Pipe ThreadAccess to 1/8”Bypass Plug

Page 79: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

74

Containment basin optional

Pressure Adjusting Screw1/8” Allen Head SocketUnder Seal Screw

Pump 1 Running Light

Pump Selector Switch

Fault Light

Pump 2 Running Light

Test Button

Control Circuit Reset

Discharge Port1/2” Pip Thread

Compound Gauge0-30” Hg0-100 PSI

Common Discharge Manifoldwith Integral Check Valves

Return Port1/4” Pipe Thread

Inlet Port1/4” Pipe Thread

1/2” D.4 Mounting Holes

Wiring for intermittent operation

Page 80: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

75

|

5”

|C

9.20

Dim

ensi

on

s

Mo

del

AB

CD

SP

M-1

56.

8815

.50

——

SP

M-3

07.

4416

.13

——

SP

M-6

58.

9619

.50

——

SP

M-1

3510

.94

21.7

0*

7.75

*21

.70

*SP

M-1

35 3

PH

AS

E

SP

M-3

PH

AS

E

Page 81: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

76

Mo

del

AP

ipe

Tap

SP

M-1

5-D

A14

.94

1/4

SP

M-3

0-D

A16

.53

1/4

SP

M-6

5-D

A16

.90

1/4

SP

M-1

35-D

A21

.37

3/8

Dim

ensi

on

sD

up

lex

Au

tom

atic

34.5

Page 82: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

77

Mo

del

AP

ipe

Tap

SP

M-1

5-D

M14

.94

1/4

SP

M-3

0-D

M16

.53

1/4

SP

M-6

5-D

M16

.90

1/4

SP

M-1

35-D

M21

.37

3/8

Dim

ensi

on

sD

up

lex

Man

ual

Page 83: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

78

INSTALLATION DATA

SPM Single and Duplex Manual Models

SPM Single and Duplex Manual units are capable ofsupplying fuel oil to heating units or tanks located up to200 feet above the supply pumps. They are designedfor use in maintained pressure or open loop systems.Pump pressures can be set at a range from 10 psi to100 psi. See Correct Supply Line Size charts, for maxi-mum discharge head.

Tank to Pump Connections

Connect suction line from the tank to preferred supplypump inlet port. Connect return line from pump returnport to tank. Internal 1/8" bypass plug (factory installed)must be in position for recommended two-pipe opera-tion. Be certain all plugs and connections are secureand leak tight.

The correct suction line size can be determined byreferring to the charts. Generally, the return line shouldbe sized the same as the suction line. Check valves inthe suction lines between the tank and SPM unitsassure that pumps are full of oil, ready for service.Check valves must be oil tight. Low pressure dropswing type are recommended to minimize friction loss.

For SPM Duplex Manual models, preferred installationcalls for a separate suction line from tank to pump foreach pump/motor unit. If system failure occurs becauseof a gross leak in the suction line of the primary unit, thesecond unit can still provide backup service. Checkvalves can be installed in return lines to allow removalof inactive pump for servicing, while primary pump con-tinues to run.

These typical installation diagrams, illustrating a main-tained pressure supply system or optional open loopsystem, for continuous pump operation, are shown forreference only. Compliance to all applicable codeswhere installed is the sole responsibility of the installer .

Page 84: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

79

*R

equi

red

if op

tiona

l ret

urn

loop

is n

ot u

sed

+N

ot s

uppl

ied

by W

ebst

er

+

+*

+

+ +

Page 85: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

80

SPM Duplex Automatic Models

SPM Duplex Automatic units consist of two SPM Seriespump/motor assemblies and an electrical control panel.They are designed for use in maintained pressure sup-ply systems only. if system pressure falls below a pre-set level, the control automatically switches from the pri-mary pump/motor unit to the secondary unit. If the backuppump/motor unit also fails to reach or maintain presetsystem pressure, the control also shuts of f the backupunit.

A pump selector switch allows the two pump/motor unitsto be manually alternated for even wear on each pump.Pump pressures can be set at a range from 10 psi to100 psi. See Correct Supply Line charts, for maximumdischarge head.

Tank to Pump Connections

Units should be set for two-pipe operation. Preferredinstallation calls for a separate suction line from tank topump for each pump/motor unit. If system failure occursbecause of a gross leak in the suction line of the primaryunit, the second unit can still provide backup service.

The correct suction line size can be determined byreferring to the charts Generally , the return line shouldbe sized the same as the suction line. Low pressuredrop, swing type check valves can be installed in thesuction lines, assuring that pumps are full of oil, readyfor service. Check valves in return lines allow removalof inactive pump for servicing. Use of shutoff valves inreturn lines is not recommended. Be certain all plugsand connections are secure and leak-tight.

+ Not supplied by Webster

+ +

Page 86: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

81

+ + +

+

+

+

*

*R

equi

red

if op

tiona

l ret

urn

loop

is n

ot u

sed

+N

ot s

uppl

ied

by W

ebst

er

Page 87: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

82

SPM LINE SIZINGCorrect sizing of the suction and discharge linesbetween the storage tank and supply unit is vital. Theuse of tubing or pipe which is too small can result inrestricted oil supply. The following charts are listed tohelp in line sizing for supply unit installation.

The charts can assist in determining the suggested min-imum suction and discharge line sizes for StandardSchedule 40 iron or steel pipe (IPS) and for Type K cop-per tubing, which is recommended for undergroundservice.*

To use the line sizing charts, first a supply unit must besized to meet the specific application. Once this hasbeen accomplished, the unit model number (ex. SPM-30) should be used as a guide in referring to the correctsuction and/or discharge sizing charts.

NOTE: The use of pipe or tubing which is too small cancause increased frictional losses. The result could be aninadequate system discharge pressure. Check localand state codes pertaining to oil heating systems forany requirements which may af fect the installationand/or operation of the system.

The following charts apply to all SPM Single, SPMDuplex Manual and SPM Duplex Automatic models.These charts are not intended to be used in sizing pipefor any other supply or transfer pump/motor units.

*Charts represent maximum horizontal run vs. verticallift or vertical head for Standard Schedule 40 iron orsteel pipe (lPS) and for Type K copper tubing, recom-mended for underground service. The actual OD andwall thickness are indicated for each tube size. (NOTE:The nominal size of Type K tubing is 1/8” smaller thanactual OD.)

Page 88: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

83

RE

CO

MM

EN

DE

DS

UC

TIO

N L

INE

SIZ

ES

PM

-15

Page 89: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

84

RE

CO

MM

EN

DE

DS

UC

TIO

N L

INE

SP

M-3

0

Suc

tion

Cha

rts

repr

esen

t max

imum

ho

rizo

nta

l ru

n v

s. v

ert

ica

l lift

fo

rS

tand

ard

Sch

edul

e 40

iron

or

stee

lpi

pe (

IPS

) an

d fo

r Ty

pe K

cop

per

tub

ing

, re

com

me

nd

ed

fo

r u

nd

er-

grou

nd s

ervi

ce.

The

act

ual O

D a

ndw

all

thic

kne

ss a

re in

dic

ate

d f

or

each

tube

siz

e. (

NO

TE

: The

nom

inal

size

of

Type

K tu

bing

is 1

/8”

smal

ler

than

act

ual O

D.)

Page 90: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

85

RE

CO

MM

EN

DE

DS

UC

TIO

N L

INE

SIZ

ES

PM

-65

Page 91: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

86

RE

CO

MM

EN

DE

DS

UC

TIO

N L

INE

SP

M-1

35

Suc

tion

Cha

rts

repr

esen

t max

imum

ho

rizo

nta

l ru

n v

s. v

ert

ica

l lift

fo

rS

tand

ard

Sch

edul

e 40

iron

or

stee

lpi

pe (

IPS

) an

d fo

r Ty

pe K

cop

per

tub

ing

, re

com

me

nd

ed

fo

r u

nd

er-

grou

nd s

ervi

ce.

The

act

ual O

D a

ndw

all

thic

kne

ss a

re in

dic

ate

d f

or

each

tube

siz

e. (

NO

TE

: The

nom

inal

size

of

Type

K tu

bing

is 1

/8”

smal

ler

than

act

ual O

D.)

Page 92: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

87

RE

CO

MM

EN

DE

DD

ISC

HA

RG

E L

INE

SIZ

ES

PM

-15

Page 93: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

88

RE

CO

MM

EN

DE

DD

ISC

HA

RG

E L

INE

SP

M-3

0

Dis

char

ge C

hart

s re

pres

ent m

axi-

mum

hor

izon

tal r

un v

s. v

ertic

al li

ftfo

r S

tand

ard

Sch

edul

e 40

iron

or

stee

l pip

e (I

PS

) an

d fo

r Ty

pe K

cop

-p

er

tub

ing

, re

com

me

nd

ed

fo

ru

nd

erg

rou

nd

se

rvic

e.

Th

e

act

ua

lO

D a

nd w

all t

hick

ness

are

indi

cate

dfo

r ea

ch tu

be s

ize.

(N

OT

E:

The

nom

inal

siz

e of

Typ

e K

tubi

ng is

1/8

”sm

alle

r th

an a

ctua

l OD

.)

Page 94: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

89

RE

CO

MM

EN

DE

DD

ISC

HA

RG

E L

INE

SIZ

ES

PM

-65

Page 95: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

90

RE

CO

MM

EN

DE

DD

ISC

HA

RG

E L

INE

SP

M-1

35

Dis

char

ge

Cha

rts

repr

esen

t max

i-m

um h

oriz

onta

l run

vs.

ver

tical

lift

for

Sta

ndar

d S

ched

ule

40 ir

on o

r st

eel

pipe

(IP

S)

and

for

Type

K c

oppe

rtu

bin

g,

reco

mm

en

de

d f

or

un

de

r-gr

ound

ser

vice

. T

he a

ctua

l OD

and

wa

ll th

ickn

ess

are

ind

ica

ted

fo

rea

ch tu

be s

ize.

(N

OT

E: T

he n

omin

alsi

ze o

f Ty

pe K

tubi

ng is

1/8

” sm

alle

rth

an a

ctua

l OD

.)

Page 96: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

91

RE

CO

MM

EN

DE

DD

ISC

HA

RG

E L

INE

SIZ

ES

PM

-15-

DA

Page 97: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

92

RE

CO

MM

EN

DE

DD

ISC

HA

RG

E L

INE

SP

M-3

0-D

A

Dis

char

ge

Cha

rts

repr

esen

t max

i-m

um h

oriz

onta

l run

vs.

ver

tical

lift

for

Sta

ndar

d S

ched

ule

40 ir

on o

r st

eel

pipe

(IP

S)

and

for

Type

K c

oppe

rtu

bin

g,

reco

mm

en

de

d f

or

un

de

r-gr

ound

ser

vice

. T

he a

ctua

l OD

and

wa

ll th

ickn

ess

are

ind

ica

ted

fo

rea

ch tu

be s

ize.

(N

OT

E: T

he n

omin

alsi

ze o

f Ty

pe K

tubi

ng is

1/8

” sm

alle

rth

an a

ctua

l OD

.)

Page 98: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

93

RE

CO

MM

EN

DE

DD

ISC

HA

RG

E L

INE

SIZ

ES

PM

-65-

DA

Page 99: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

94

RE

CO

MM

EN

DE

DD

ISC

HA

RG

E L

INE

SP

M-1

35-D

A

Dis

char

ge

Cha

rts

repr

esen

t max

i-m

um h

oriz

onta

l run

vs.

ver

tical

lift

for

Sta

ndar

d S

ched

ule

40 ir

on o

r st

eel

pipe

(IP

S)

and

for

Type

K c

oppe

rtu

bin

g,

reco

mm

en

de

d f

or

un

de

r-gr

ound

ser

vice

. T

he a

ctua

l OD

and

wa

ll th

ickn

ess

are

ind

ica

ted

fo

rea

ch tu

be s

ize.

(N

OT

E: T

he n

omin

alsi

ze o

f Ty

pe K

tubi

ng is

1/8

” sm

alle

rth

an a

ctua

l OD

.)

Page 100: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

95

The adjusting screws on the Pressuretrol, located in thefactory wired control panel, should be set carefullyaccording to instructions, below.

Setting Pump Pressure

1. Set the differential scale indicator on the pressuretrolat approximately 5 (half-way between 10 and bottom ofscale). This permanently sets the differential scale. Setmain scale indicator at 0, so supply pump can run con-tinuously during purging of supply line.

2. Purge lines. Run both supply pumps to assure bothare oil filled. For priming purposes, OSV valves can bemanually operated by inserting a stif f wire (paper clip)through the cover hole, and depressing the diaphragmplate.

3. Pressure adjustment, pump one: Install compoundgauge in tee fitting in supply line of highest or mostremote burner. After starting pump one, start all burn-ers. With all burners operating at maximum firing rate,adjust pump one so gauge at remote burners, reads 20 psi.

4 Pressuretrol adjustment: With all burners firing, switchto pump two and adjust pump two so gauge at lastburner reads slight positive pressure (2-5 psi).Gradually increase the pressuretrol main scale settinguntil pump two stops, pump one starts, and alarmbuzzer sounds. Allow pump one to run and build pres-sure. With pump one running and pump two off, turnpump two pressure adjusting screw about one-quarterturn clockwise.

5. Pressure adjustment, pump two: Move selectorswitch to off momentarily, then back to pump two. Alarmwill shut of f and pump two will start. Adjust pump twopressure setting so it is the same as pump one (set instep three). Switch back and forth between both pumps

DifferentialScale

AdjustingScrew

Main Scale

AdjustingScrew

MainScale

Indicator

DifferentialScale

Indicator

SPM Duplex Automatic Controls

Page 101: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

96

to confirm pressure settings are identical. Shut of f allburners. Pressure at any oil safety valve in system mustnot exceed maximum operating pressure of 60 psi,when supply pump is running and all burners are of f.

ELECTRICAL CONNECTIONS

The electrical connections between the pump/motorassemblies and control panel are made at the factory .Connect electric service to the terminal strip in the con-trol panel using conduit and wire sizes as required bylocal codes.

Control circuits operate on 1 15 volts. Always connectwhite neutral wire to Terminal 2. Never connect 230 voltsbetween Terminal L1 and Terminal 2. Green ground wirefrom power source should be connected to one of thepanel mounting screws.

Important: SPM-135-DA motors are dual voltage andare prewired for 230 volts at factory . To operate on 115volts, consult motor manufacturer 's instructions accom-panying unit for proper wiring. Before starting unit, checkmotor voltage and confirm that 115 volt motors are wiredto panel as shown in Figure One with Terminal 2 andTerminal L2 Jumper and that 230 volt motors are wiredas shown in Figure Two without Terminal 2 and TerminalL2 Jumper.

Figure 1 — 15 Volt MotorConnections

Figure 2 —230 Volt MotorConnections

Page 102: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

97

SPMV SERIES

High Capacity AC Motor/Pump Units 430-1730 gph

Designed for high capacity applications where 430-1730 gph are required. Quiet running, gear type pumpsare available in four sizes and incorporate hardenedintegral shafts, journals and gears, special anti frictionbearings, Buna N seals, and cast iron gear plates.Standard motors ranging from 1/2 hp to 7.5 hp (373 Wto 5.6 kw) are 1725 rpm NEMA “C” face, 115 volt single-phase or 230 volt three-phase, 60 cycle type with TEFCenclosures through 2 hp (1490 W) and OPDP enclo-sures over 2 hp (1490 W).

Webster AC motor/pump high capacity fuel oil supplyunits are designed to be used with fuel oils includingJP4 whose viscosities do not exceed 6,000 S.U.S. andwith a suction less than 10” of mercury or an inlet pres-sure not to exceed 35 psi continuously (capable ofintermittent duty at 10,000 S.U.S., 20” of mercury and50 psi inlet). The unit is designed to operate in -20°F to+200°F conditions. The motor is precision aligned andcoupled to the pump with a machined adapter and flex-ible couplings.

Page 103: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

98

SPMV DUPLEXPump/Motor Units

Available in flow rates from 430 GPH through 1730GPH. Systems can be designed for single phase115/208/230V, 60 or 50CY , or three phase208/230/460V, 60 or 50CY , applications. The SPMduplex models consist of two pump and motor assem-blies with a pre-piped common discharge manifold. Onepump operates continuously, with the second providingbackup services if the main pump fails. Either automat-ic (SPM-DA models) or manual (SPM-DM models) con-trols are available. The duplex automatic series aredesigned specifically for buildings where a constantsupply of oil must be assured...hospitals, apartmentbuildings, schools and other commercial or industrialbuildings. The duplex pump set has a second pump forstandby or auxiliary service. Furnished with automaticor manual standby controls, the duplex automatic isequipped with a pressure sensing device which detectsloss of pressure of primary pump. If standby pump isbrought into service, an alarm sounds which indicatesmalfunction in primary pump. The electric control circuiton the duplex automatic pump set is equipped with alead-lag switch to permit manual alternation of pump toprovide even pump wear . The manually operatedduplex pump sets offer the same protection as the auto-matic except the standby pump must be turned on man-ually which requires that maintenance personnel alwaysbe available.

Page 104: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

99

SPECIFICATIONSSPMV SERIES

AC High Capacity Fuel Oil Supply Units

Capacity:430 to 1730 gph with fluid viscosity to 10,000 SSU.

Pressure:Inlet pressure should not to exceed 3 psi. Outlet pressure up to 500 psi.

Fluid Temperature Limits: -20° F to +200° F.

Motors:Standard: 60 cycle, 1750 rpm, NEMA 56C frame.1/2 through 7 1/2 hp available.To be specified when ordering: Single-phase 115/230VAC, or three-phase 230/460 VAC. ODP or TEFC.

Porting: 1” NPT (086K-194K)1 1/2 X 1 1/4 NPT (237K-388K)

Mounting: Integral mounting foot.

Maximum Inlet Vacuum: 15” HgContinuous operation: 10” HgUse of external filter recommended.

In applying these supply units, the pressures indicatedare at the pump outlet. You must also consider line losses.

All pumps relying on atmospheric pressure to push thefuel oil into them are subject to cavitation. As fuel vis-cosity (thickness) increases, the tendency for cavitationbecomes greater. Therefore, it is best to mount thepump at the base of the tank and to use the largestdiameter, shortest length, and straightest inlet possible.A large diameter inlet pipe or hose necked down at thepump is preferable to a longer length of smaller diame-ter pipe because the fuel tends to adhere to the insideof the pipe.

When initially starting a unit, it is desirable and some-times necessary to have a vent valve or plug on thepressure side of the pump to facilitate its priming.

Page 105: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

100

SPMV PUMP CODE ANALYSIS SELECTION TABLES

SPM V - 50 A T /086K DA

Motor PumpPump TypeMotor Horsepower — Table 1

plus Table 4Motor Phase — Table 2Motor Enclosure — Table 3Pump Model — Table 4Configuration Tables

Table 1. Motor Horsepower(1725 rpm Standard)

No. Description

50 .50 hp75 .75 hp

100 1.0 hp150 1.5 hp

200 2.0 hp300 3.0 hp500 5.0 hp750 7.5 hp

Table 2. Motor PhaseCode Description

A Single-phase, 60 cycle, 115/230 VACB Three-phase, 60 cycle, 230/460 VACX Consult factory for other types

Table 3, Motor EnclosureCode Description

T TEFC std. thru 2 hpO OPDP std. over 2 hpE Explosion Proof

Table 4. Pump Model

Under Pressure, ReadHorsepower Required at

1750 rpmMaximumgph Pump 25 100 200 300

Nominal Model psi psi psi psi439 086K .50 .75 1.00 1.50

900 194K 1.00 1.75 2.50 3.001114 237K 1.00 2.00 3.00 4.00

1730 388K 2.00 3.50 4.50 6.00

HP ratings shown are for No. 2 fuel oil. Consult factoryfor hp ratings for heavier weight oils. For lower flow ratesconsult Bulletin 131-49161. For higher pressures and/orflow rates, consult factory.

SPMV Duplex Ordering CodeWhen ordering SPMV Duplex models add suf fix:

“DM,” for manual control models, or “DA,” for automatic controlmodels.

Example: SPMV-50AT/086K-DA

5 Code Duplex UnitsDM Duplex with manual controlsDA Duplex with automatic controls

Page 106: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

101

PSI30020010025

25300

PSI300200

10025

25300

086K

194K

Page 107: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

102

PSI30020010025

25300

PSI30020010025

25300

237K

388K

Page 108: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

103

4.95

DIMENSIONS

Motor

NEMAHP Fame Type A B C D

Size (Standard)

.50 56C TEFC 6.30 9.00 8.25 9.20

.75 56C TEFC 6.30 9.00 8.25 9.201.00 56C TEFC 6.30 9.00 8.25 10.201.50 56C TEFC 6.30 9.00 8.25 11.202.00 56C TEFC 6.30 9.00 8.25 11.203.00 182TC OPDP 7.30 9.63 11.05 11.005.00 184TC OPDP 7.30 9.63 11.05 12.407.50 213TC OPDP 8.00 11.63 13.00 13.90

FPumpModel E Minimum Maximum

086K 4.90 19.05 (.50HP) 20.85 (3.00HP)194K 5.65 19.80 (.75HP) 23.10 (5.00HP)237K 8.80 22.95 (.75HP) 27.85 (7.50HP)388K 9.80 23.95 (.75HP) * 28.65 (7.50HP)

* Add 4" for Explosion Proof

SPMV Series Single and Duplex Supply Units

Dimensions for 3 PhaseDuplex AutomaticAssembly as Shown

SPMV SINGLE SUPPLY UNIT

SPMV DUPLEX AUTOMATIC SUPPLY UNIT

34.5

8.303''

9.30

Page 109: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

104

SPMB Series Single and Duplex Supply Units

B series transfer pumps are designed to provide ef ficientpumping of #1 to #6 fuel oils, in capacities from 80 to 290gallons per hour, at pressures up to 500 PSI (except #1oil). With high-density gray iron body construction, heat-treated alloy steel gears and shafts, and special antifric-tion bearings. B series transfer pumps offer superior dura-bility and high mechanical ef ficiency. Double lip V itonseals, are standard. These pumps are also available inpump and motor packages. Available in 115/230 volt sin-gle phase or 230/460 volt three phase, simplex, duplexautomatic and duplex manual configurations. All B seriespumps are UL approved.

Page 110: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

105

SpecificationsGear Sizes: 18B (.35” gear width)

37B (.70” gear width)47B (1.00” gear width)59B (1.40” gear width)

Capacity: 80 to 290 GPH @ 1750 RPM#1 to #6 fuel oil @ 75 degrees F.,100 PSI)

Pressures: #4 to #6 fuel oils - up to 500 PSI#2 fuel oil - up to 350 PSI

Operating Speeds: To 1725 RPM

Porting: * 1/2” NPTF: Side inlet and side outlet3/4” NPTF: Side inlet and sideoutlet 59B only

Shaft Seal: Standard - Double lip type, Viton

Filter: No internal filterExternal filter recommended

Relief Valve: No Relief Valve Use External Relief Valve

Inlet Pressure: 3 PSI MAX

Inlet Vacuum: 10” Hg maximum

UL Listed

SPMB DuplexPUMP/MOTOR UNITS

Available in flow rates from 80 GPH through 290 GPH. Systemscan be designed for single phase 115/208/ 230V, 60 or 50CY, orthree phase 208/230/460V, 60 or 50CY, applications, The SPMduplex models consist of two pump and motor assemblies witha pre-piped common discharge manifold. One pump operatescontinuously, with the second providing backup service if themain pump fails. Either automatic (SPM-DA models) or manual(SPM-DM models) controls are available. The duplex automaticseries are designed specifically for buildings where a constantsupply of oil must be assured...hospitals, apartment buildings,schools and other commercial or industrial buildings. The duplexpump set has a second pump for standby or auxiliary service.Furnished with automatic or manual standby controls, the duplexautomatic is equipped with a pressure sensing device whichdetects loss of pressure of primary pump. If standby pump isbrought into service, and alarm sounds which indicates malfunc-tion in primary pump. The electric control circuit on the duplexautomatic pump set is equipped with a lead-lag switch to permitmanual alternation of pump to provide even pump wear . The man-ually operated duplex pump sets offer the same protection as theautomatic except the standby pump must be turned on manuallywhich requires that maintenance personnel always be available.Available with either SPM or SPMV pump/motor units.

Page 111: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

106

MOTOR HORSEPOWER (1725 RPM STANDARD)

No. Description

25 .25 HP33 .33 HP50 .50 HP75 .75 HP100 1.0 HP150 1.5 HP200 2.0 HP300 3.0 HP

= only available in 115V or 230V single phase

MOTOR PHASE

Code Description

A Single Phase / 60 cycle / 115/208/230 VAC

B Three Phase / 60 cycle / 208 / 230 / 460 V AC

X Consult factory for other types

MOTOR ENCLOSURE

Code Description

T TEFC Std/ thru 2 HP

O OPDP Std. over 2 HP

E Explosion Proof

SPMB Ordering Code

SPMB 50 A T 18BR DM1

1

2

3

2 3 4 5

When sizing SPMB units, remember that the pressuresindicated are at the pump outlet.

All pumps relying on atmospheric pressure to push thefuel oil into them are subject to cavitation. As fuel viscos-ity (thickness) increases, the tendency for cavitationbecomes greater. Therefore, it is best to mount the pumpat the base of the tank and to use the largest diameter ,shortest length, and straightest inlet possible.

**

*

Page 112: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

107

MOTOR HORSEPOWER (1725 RPM STANDARD)Under pressure, read

horsepower required at 1750 RPMMaximum

Pump gph 25 100 200 300Model Nominal psi psi psi psiI

18BR 82 .25 .25 .25 .33

37BR 159 .25 .25 .50 .75

47BR 220 .25 .50 .75 1.00

59BR 292 .25 .50 .75 1.50

SPMB Duplex Ordering CodeWhen ordering SPMB Duplex models add suf fix:

“DM,” for manual control models, or “DA,” forautomatic control models.

Example: SPMB-50AT/18BR-DA

Code Duplex Units

DM Duplex with manual controls

DA Duplex with automatic controls

4

5

A large diameter inlet pipe or hose necked-down at the pumpis preferable to a longer length of similar diameter pipebecause the fuel tends to adhere to the inside of the pipe.

When initially starting a unit, it is desireable and sometimesnecessary to have a vent valve or plug on the pressure side ofthe pump to facilitate its priming.

Page 113: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

108

SPMB Series Single and Duplex Supply Units

DIMENSIONS

Motor

NEMA

HP Fame Type A B C

Size (Standard)

.50 56C TEFC 9.00 8.25 9.20

.75 56C TEFC 9.00 8.25 9.20

1.00 56C TEFC 9.00 8.25 10.20

1.50 56C TEFC 9.00 8.25 11.20

2.00 56C TEFC 9.00 8.25 11.20

3.00 182TC OPDP 9.63 11.05 11.00

5.00 184TC OPDP 9.63 11.05 12.40

7.50 213TC OPDP 11.63 13.00 13.90

Pump

Model E D

18BR 3.36 (.50HP) 17.06

37BR 3.71 (.75HP) 17.4147BR 4.05 (.75HP) 17.75

59BR 4.40 (.75HP) 18.10

Page 114: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

109

SPMBSINGLE SUPPLY UNIT

SPMBDUPLEX AUTOMATIC SUPPLY UNIT

(Dimensions are for 3 Phase Duplex AutomaticConsult Factory for Single Phase Dimensions)

34.5

6.12

Page 115: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

110

TRANSFER PUMP UNITSTransfer pumps/motors consist of an electric motor andWebster fuel unit. Each W ebster fuel unit has beendesigned for a variety of needs from fuel supply to fueltransfer. With capacities ranging from 9 to 150 gph at100 psi, Webster transfer units are capable of satisfyingvirtually every system supply or transfer need.

SPECIFICATIONS

35223 Series, 35202 Series, 49116 Series

Capacities:35223 Series—80 to 155 gph at 100 psi. 35202 Series—9 to 65 gph at 100 psi. 49116 Series—31 to 66 gph at 100 psi.

Maximum Working Pressure:35223 Series—80 to 200 psi.35202 Series—100 to 300 psi.49116 Series—100 psi

Motors:All motors 60 cycle, 1750 rpm, continuous duty 115 volt. 1/6 and 1/4 hp are split phase.1/2hp is capacitor start—induction run, TEFC with dual115/230 volt windings.

Fuel Units (Close Coupled to Motor):

35223 Series uses Websters' B Series Fuel Oil TransferUnits.35202 Series uses Websters' V Series or R Series FuelUnits.

49116 Series uses W ebsters' 1R00 Series FuelTransfer Units.

Mounting: Maximum Inlet Vacuum:Four bolt foot mount. 10” Hg vacuum.

Use of external filter recommended.

35223 SERIES TRANSFER UNITS

The 35223 Series Pump/Motor Unit consists of aWebster B Series fuel oil transfer pump close coupledto a 1/4 hp electric motor. This unit is designed for trans-fer of fuel oils #6 or lighter at maximum working pres-sures up to 200 PSI depending on motor hp.

Page 116: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

111

SE

LE

CT

ION

TA

BL

E

3522

3 S

erie

s P

um

p/M

oto

r U

nit

sM

axim

um

Max

imu

mM

oto

rM

oto

rP

um

pW

ork

ing

Ou

tlet

Flo

wD

im. A

Mo

del

sV

olt

age

ho

Mo

del

Pre

ssu

reat

100

psi

(max

.)D

im.

B35

223-

111

51/

418

B20

0 ps

i80

gph

16.0

46.

3235

223-

311

51/

437

B10

0 ps

i15

5 gp

h16

.39

6.67

Page 117: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

112

35202 SERIES TRANSFER UNITS

35202 Series Pump/Motor Units consist of a Webster RSeries or V Series fuel unit with integral pressure valve,close coupled to a motor . This series is available with1/6, 1/4 cr 1/2 hp electric motors with a pumping capac-ity to 65 gph at 100 psi.

Page 118: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

113

SE

LE

CT

ION

TA

BL

E

Max

imu

mP

um

pg

ph

at

Wo

rkin

gB

lock

edM

axim

um

Su

ctio

nM

oto

rM

oto

rM

oto

rF

uel

un

itP

ress

ure

No

zzle

gp

h a

tW

ork

ing

Cap

acit

yM

od

els

Vo

ltag

eTy

pe

No

.h

pTy

pe

No

.p

siW

atts

100

psi

Pre

ssu

reg

ph

3520

211

534

499-

31/

42R

223C

-5B

Q14

300

210

3023

7035

202-

211

534

499-

11/

62R

111C

-5B

Q3

150

7512

1035

3520

2-9

Less

mot

or,i

nclu

des

acce

ssor

ies

2R21

3C-5

BQ

1415

013

030

2970

3520

2-10

Less

mot

or,i

nclu

des

acce

ssor

ies

2R61

6C-5

BQ

1415

024

565

6012

535

202-

2711

534

499-

11/

61R

162C

-4B

Q6

125

709

730

3520

2-29

115/

230

dual

3449

9-6

1/2

2R62

6C-5

BQ

1430

041

065

5012

535

202-

3511

5/23

0 du

al34

499-

61/

2V

022C

-4D

020

300

270

4020

5035

202-

3811

534

499-

81/

3V

002C

-4E

J10

017

565

6565

Abo

ve C

apac

ity in

gph

at 1

725

rpm

pum

ping

#2

fuel

oil

at 7

5°F

.N

OT

E:

3520

2-38

rat

ings

are

for

1000

SS

U fu

el.

Page 119: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

114

|

5”

|B

1.5

9.20

*352

02-2

9 A

ND

352

02-3

5

Dim

ensi

on

s

Mo

del

AB

Ou

tlet

Po

rt35

202

15.6

17.

391/

4-18

NP

TF

3520

2-9*

*1/

4-18

NP

TF

3520

2-2

14.0

96.

891/

8-27

NP

TF

3520

2-27

13.4

77.

391/

8-27

NP

TF

*352

02-2

919

.45

5.75

1/4-

18 N

PT

F35

202-

10**

*352

02-3

518

.83

5.13

1/4-

18 N

PT

F

**D

imen

sion

s sa

me

as 3

5202

-29

Less

Mot

or*S

ee D

raw

ing

A

4.88

SP

M W

ITH

A “

V”

OR

“R

” S

ER

IES

PU

MP

HEA

DS

ING

LE SUPP

LYU

NIT

US

ING

A 5

6CFR

AM

E M

OTO

R

Page 120: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

115

49116 SERIES TRANSFER UNITS49116 Series Pump/Motor Units consist of a W ebster 1R00 Series Fuel Transfer Unit close coupled to a 1/4 hpelectric motor. This unit requires the use of an externalpressure regulating valve. The 49116 Series is capableof up to 66 gph at 100 psi.

SELECTION TABLE

DeliveryReplaces Pump Suction gphDiscount Type Capacity 100 psi

Models Model No. gph ① ①

49116 35223-19 1R003C-4EH 48 3135223-21

49116-1 35223-23 1R004C-4EH 66 4335223-25

49116-2 — 1R006C-4EH 95 66

① Capacity in gph at 1725 rpm pumping #2 fuel oil at75°F

For typical installation suggestions, please refer to theSPM Supply Pump/Motor section.

NOTE: The installation drawings contained in this serv-ice guide are intended for referenc e use only. Consultyour local heating contractor for specific installation rec-ommendations and designs which comply with the stateand local codes in your area.

Page 121: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

116

Dim

ensi

on

s

Mo

del

AB

4911

614

.44

4.72

4911

6-1

15.0

65.

3449

116-

215

.06

5.34

Page 122: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

117

FUEL UNIT ACCESSORIESMOUNTING ACCESSORIES

Webster oil heat product s are recommended for theirconvenience and ease of installation. Seven types ofmounting flanges, brackets, shaft sleeves and cou-plings are manufactured and stocked for use withWebster fuel units and pumps.

Complete dimension drawings are shown.

SELECTION TABLE

Dimensions

Description NumberHi-Foot Flange A45Q 1 Figure One4 Bolt Adapter Flange For Standard HUB(Nema 56CMotor Mount) 41489 Figure ThreeHorizontalMounting Flange A43Q7 Figure FourBell Housing 34330 Figure FiveAdapter For 1100013 Has MTG EARSB Pump 1100012 Figure Two

4 Bolt 56C Adapter 80316-1 Figure SixFlange for Special 2 Bolt Pump MTG

34330

11000121100013 hasMTG EARS

41489

A43Q7

A45Q180316-1

Page 123: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

118

4.5

Figure Two-1100012

Figure Five-34330,48N Frame

Figure Four-A43Q7

Figure Six-80316 -1

Page 124: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

119

OIL SAFETY U/L® LISTED

VALVESOIL SAFETY VALVESINSTALLATION INSTRUCTIONS

Webster OSV® valves can be used for the followingapplications which require slightly different installations:

1. Preventing tank siphoning and oil leaks in the eventof line breaks. (See Section “A”)

2. For use with a supply pump (booster pump) to pre-vent excessive pressure at the inlet of the burner fuelunit. (See Section “B”)

Many state and localcodes require a devicethat will automaticallyshut off the oil supplybefore it enters a build-ing should the linebetween the deviceand the burner be bro-ken. NFPA standardsrequire that the pres-sure at the burner fuelpumps must not exceed 3 PSI. The Webster OSV® sat-isfies both requirements when properly installed. Checklocal codes for any special requirements.

SECTION “A”

Using the OSV® valve to help prevent oil spills from bro-ken or corroded lines and fittings.

Operation

A recent Environmental Protection Agency sponsoredstudy found that most oil leaks are found in the pipingrather than the tank. Webster OSV® valves help preventoil spills by stopping oil flow in the event of line breakscaused by corroded lines or leaky fittings. The OSV® 9is mounted in the supply line as close as possible to thetank. Operation is simple. The OSV® requires a vacuumon its outlet side to open the valve and allow oil flow .When the burner is shut down, there is no vacuum fromthe fuel unit and the OSV ® valve is closed—oil flow isstopped. When the burner starts up, vacuum from thefuel unit opens the OSV®, allowing oil to flow.If a corroded broken line or a loose fitting causes a leakto develop between the OSV® and burner, air enters theline. Fuel unit vacuum is reduced and the OSV® will notopen, preventing tank siphoning and a major spill.

BIO OIL SAFETY VALVE UPGRADEOSV38 and OSV50Webster currently has an Oil Safety V alve for Bio andWaste Oil applications. This valve is U/L listed for BioFuel and is compatible with a wide range of other fuelssuch as B20-B100, #1-#2 Fuel Oil, Diesel, Kerosene andWaste Oil, with a Temperature Range of -40 to 140ºF.

Page 125: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

120

INSTALLATION

The OSV® should be mounted on the supply line asclose to the tank as possible.

CAUTION: DO NOT mount the OSV® more than threefeet above the fuel unit inlet or more than three feetabove the lowest point in the fuel line connecting theOSV® to the burner fuel unit.

See Figures 1 & 2 below.

Figure 2. Mobile Home Gravity System

Failure to observe the above caution will compromisevalve action and may result in tank siphoning action inthe event of a line failure between tank and burner .

TROUBLESHOOTING

The OSV® valve will not open during fuel unit operationif there is any air leak in the system between OSV® andburner that prevents development of the operationalvacuum required. (See Table 1).

If there is no oil flow to burner or prime is lost

A. Check to see if OSV® valve is stopping oil flow. Turnon burner and manually depress OSV ® diaphragmplate with paper clip to see if burner fires up.

Page 126: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

121

1. Check system vacuum.Use a vacuum gauge at fuel unit inlet side. Run burner and shutoff. Vacuum should be maintained. Loss of vacuum indicates air leak.

2. Check all above ground fittings and line for air leaks.3. Conduct a pressure check of the line.4. If line does not maintain pressure, the line probably

has a break and needs replacing.B. If there is no oil flow even when OSV® valve is manually

opened then check filter, shut-off or foot valve or tank.CAUTION: Always disconnect the OSV® when blowingout the lines with compressed air or damage to thevalve will result.NOTE: Outside installation may not be suitable wherethe OSV® would be exposed to temperatures belowfreezing.

Dimensions & Specifications

Standard Model use prefix “OSVA”BIO Model use prefix “OSV”The BIO OSV valve is U/L listed for Bio Fuel and is com-patible with a wide range of other fuels such as B20-B100, #1-#2 Fuel Oil, Diesel, Kerosene, Diesel andWaste Oil.Temperature Range -40 to 140 Degrees F

SECTION “B”For use with a supply pump (booster pump) to preventexcessive pressure at the inlet of the burner fuel unitOperation/InstallationWebster Oil Safety Valves provide important protectionin oil burner supply systems with pressurized supplylines. By isolating burner fuel units from supply linepressure sources (a supply pump or overhead tank, forexample), the OSV® relieves pressure strain on fuel unitinlets and seals.

For this application, the OSV ® is installed close to theburner assembly. A sustained vacuum at the outlet sideof the OSV®, generated by fuel unit operation, causesthe valve to open.

Port Sizes3/8 and 12 NPTF

Page 127: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

122

The OSV® operates as a pressure reducer, with supplyline pressure on the valve inlet side and fuel pump vac-uum on the valve outlet side.

In systems with burners connected for one-pipe opera-tion, GPH flow through the valve is the same as theburner nozzle firing rate. In two pipe operation, GPHflow through the valve is the same as the fuel unit suc-tion capacity. Refer to fuel unit manufacturer's specifi-cation for inlet suction capacity . Operation of OSV ®

valves in parallel is not recommended.Recommended Maximum Flow Rates and Pressure

Tbl.1 OSV® 38 and OSV® 50

PSI PSI PSI PSI PSI PSI5 15 30 40 50 60

1 gph 2.5 2.7 3.5 4.5 5.0 5.515 gph 2.7 3.0 4.0 5 0 5.5 6.032 gph 3.7 4.0 4.7 5.2 6.0 7.045 gph 4.0 4.5 5.0 6.0 7.055 gph 4.5 5.0 5.760 gph 5.0 5.2 6.0 Do not operate70 gph 5.5 6.0 in this region

Vacuum (inches Hg) to operate valve is shown for vari-ous flow and pressure conditions.

Values given are averages of test results and may varyslightly.

Entrapment Caution

In supply systems having a check valve on the supplypump discharge, an entrapment condition may existbetween the supply pump and OSV®. In the burner OFFcondition, cold oil in the line expands when heating toroom temperature, causing a line pressure increase thatmay prevent the OSV ® from operating, or may causeleakage at the threaded joints. The condition may beobserved by use of a pressure gauge at the inlet side ofthe OSV®, or on the discharge side of the supply pumpcheck valve. Correction requires use of a pressure reliefvalve as shown in Figure 3, set to insure a maximum 60PSI at any OSV® inlet under all conditions.

Figure 3. Supply Pump Systems — Multi Level

Inlet PressureFlowthru

Valve

Page 128: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

123

OPEN LOOP SYSTEM

To insure a flooded supply line, a standpipe before thejunction of the supply line with the return line is required.The standpipe on the supply line must be at least threefeet higher than any point in the supply line systembefore joining the return line. Use of a W ebster 48598vacuum breaker is recommended.

Figure 4. Central Supply Systems tor Mobile HomesGENERAL CONSIDERATIONS

PORTING CONNECTIONS

The OSV® valve is installed in the supply line betweenthe tank and burner. Its location depends on the appli-cation (see sections A & B). The OSV® “IN” port is con-nected to the tank side. The OSV® “OUT” port is con-nected to the burner side of the line. Non hardeningpipe dope is recommended for use on the fittingthreads. Do not use teflon tape, as it may void all war-ranties.

MOUNTING

The OSV® can be mounted in any position. In thoseenvironments where dirt or moisture is particularly aproblem, the preferred position is with the cover down.This allows any moisture from the diaphragm area todrain out the manual access hole.

FILTER

A dependable in-line filter is recommended between thetank and OSV® to help assure optimum valve perform-ance. Dirt on the valve s eat area could prevent thevalve from sealing tightly.

PRIMING

For priming purposes, the OSV® can be manually oper-ated by inserting a paper clip or stif f wire through themanual access hole, and depressing the diaphragmplate. Remove the wire immediately if oil appears at thefuel unit vent, the burner fires up, or there is any sign ofoil at the burner fuel unit.

CHECK LOCAL CODES

The installer is responsible for complying with all appli-cable codes. Typical installation diagrams are shown forreference only.

Page 129: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

124

REGULATING VALVES FOROIL HEATING SYSTEMSRV SERIES

Webster RV Series valves are designed to provide fueloil pressure regulation in oil heating applications suchas transfer or supply pump systems or high firing capac-ity burners. RV valves will handle #1 through #6 gradefuel oil in rated pressures ranging from 20 to 500 psi(1.4 to 34.5 bar). RV-2100 Series models regulate pres-sure for capacities to 150 gph (568 I/hr) and R V-3000Series valves regulate pressure to 600 gph (22701/hr).RV-2000 models regulate pressure and also providedelivery cutoff for capacities to 100 gph (3781/hr).

RV-2000 RV-3000RV-2100

SPECIFICATIONS

RV-2000

For all fuel oils, #1 through #6. Combines pressure reg-ulation and cut-of f. Chrome plated piston valve andimproved composition sealing disc resist corrosion;gives positive seal and sharp, clean cut-off. Capacitiesto 100 gph.

RV-2100

Same as RV-2000 except does not have delivery cut-off. Pressure regulating only. Capacities to 150 gph.

RV-3000

Same as RV-2100 except capacities to 600 gph.

Page 130: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

125

Page 131: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

126

SE

LE

CT

ION

TA

BL

EP

rese

tF

acto

ryA

dju

stm

ent

Cap

acit

yS

etTy

pe

Ran

ge

gp

hP

ress

ure

Nu

mb

erD

escr

ipti

on

(psi

)(M

ax.)

(psi

)R

V-2

001

100-

165

100

100†

RV

-200

2R

egul

atin

g &

100-

330

100

100†

RV

-200

3C

ut-o

ff V

alve

10-2

510

010

†R

V-2

004

40-

110

100

100†

RV

-210

110

0-16

515

010

0†R

V-2

102

Reg

ulat

ing

100-

330

150

100†

RV

-210

3V

alve

10-2

514

010

†R

V-2

104

80-1

4015

010

0†

RV

-300

025

0-55

060

025

0†R

V-3

001

Reg

ulat

ing

50-3

3060

010

0†R

V-3

001D

AR

Val

ve50

-330

600

100†

RV

-300

250

-220

600

100†

RV

-300

310

-55

600

10†

RV

-210

1-4

Spe

cial

100-

165

150

150*

RV

-210

2-4

Reg

ulat

ing

100-

330

150

150†

RV

2102

-4A

10

0-33

015

010

0†R

V21

02-4

B10

0-33

015

012

5†R

V21

02-4

C10

0-33

015

015

0†R

V21

02-4

J10

0-33

015

030

0†R

V-2

104-

3V

alve

s80

-140

150

100*

RV

-210

4-4

(See

Not

e 1)

80-1

4015

010

0*

(PS

I R

ange

and

Set

ting

base

d on

50

gph

flow

, #2

Fue

l O

il, e

xcep

t RV

-300

0 S

erie

s is

bas

ed o

n 15

0gp

h flo

w.)

Val

ve m

ay b

e re

set a

t ins

talla

tion

to m

eet s

yste

mre

quire

men

t.

*Val

ve s

tam

ped

at fa

ctor

y w

ith p

rese

t pre

ssur

e.

†Val

ve n

ot s

tam

ped

with

fact

ory

pres

et p

ress

ure

NO

TE

1:

The

se s

peci

al v

alve

s m

eet t

he r

equi

re-

me

nts

o

f th

e N

ew

Y

ork

C

ity's

B

oa

rd o

f A

irR

esou

rces

. T

he v

alve

bod

y di

men

sion

s ar

e th

esa

me

as th

ose

show

n at

the

right

for

the

RV

-200

0an

d R

V-2

100

Ser

ies

valv

es. D

iffe

renc

es a

re: 1

)T

he t

op a

nd b

otto

m v

alve

end

cap

s ar

e ta

per

pinn

ed t

o th

e bo

dy to

pre

vent

rem

oval

. 2)

The

pres

sure

adj

ustm

ent s

eal s

crew

and

was

her,

once

inst

alle

d by

the

cust

omer

, ca

nnot

be

rem

oved

topr

even

t ta

mpe

ring

with

the

set p

ress

ure.

3/8

3/8

3/4

1/4

1/4

1/4

1/4

1/4

1/4

3/8

1/4

Po

rtin

g

Page 132: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

127

INSTALLATION DATA

Page 133: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

128

Relief Valve Installation

ToTank

Pressure Pressure

ToTank

RV-2000

The RV-2000 series regulating valve can also be usedas a relief valve. Designed to provide system pressurerelief for #1 through #6 fuel oil grades and for ratedpressure ranges of 0 to 500 psi. @150 gph or less. Thefollowing adjustment ranges are available 100-330 psiuse RV-2002, 10-25 psi use R V-2003, 40-110 psi useRV-2004. Pipe as configured.

Page 134: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

129

INSTALLATION DATA

2' to 4'

VACUUM BREAKER (48598)Incorporates Viton “O” Ring seat, 3/8-18 NPTF ports.Can be used as a suction line check valve.

Page 135: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

130

TroubleshootingGENERAL PUMP PROBLEMS

• Noisy pump• Pump will not prime• Rumble coming from burner at start-up• Oil leaking from pump cover gasket or blown cover

gasket• Pump looses prime after an extended shutdown• Vacuum coming from return port on oil pump (two

pipe installation)• Pump seizes at start-up, blows seal, damage to

discharge pressure gauge• Supply unit does not run • Unit runs but no oil reaches supply pump • Unit supplies oil to distribution system, but no

delivery of oil at OSV valves• Oil delivery at OSV valves, but burners do not fire • Burner pump seal damaged • Pressure increases in supply line after shutdown • Oil Safety Valve does not open

Noisy pump

Check for air leaks

Check for high vacuum condition, (10 in. for singlestage and 15 in. for two stage pumps)

Pump will not prime

Measure suction inlet vacuum, should not exceed15 in. of vacuum

Check that all plugs and suction line connections areairtight

Be certain by-pass plug is in position on two pipeinstallation

Use adequate size suction line

Be certain suction line filter or strainer has adequatecapacity

Rumble coming from burner at start-up

Check cutoff at pump or external solenoid

Oil leaking from pump cover gasket(s) blown covergasket(s)

Check for correct pump rotation

Pump looses prime after an extended shutdown

Check all pipe connections for air leaks

Return line not submersed in oil

In supply pump applications the return loop mayneed a vacuum breaker installed to prevent siphoning

Page 136: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

131

Vacuum coming from return port on oil pump(two pipe installation)

By-pass plug not installed

If by-pass plug is installed check for blockedsuction line

Pump seizes at start-up. blows seal. damageto discharge pressure gauge

Check for blocked return line or drain port from pump

By-pass plug should be removed on single pipeinstallation

SUPPLY PUMP PROBLEMS

Supply Unit does not run

Check motor electrical connections

Check for obstruction in return line such as a reversedcheck valve

Check circuit breaker and correct possible overload

Unit runs. but no oil reaches supply pump

Measure suction inlet vacuum, should not exceed 15 in. of vacuum

Check that all plugs and suction line connections areairtight

Be certain by-pass plug is in position

Use adequate size suction line

Be certain suction line filter or strainer has adequatecapacity

Unit supplies oil to distribution system, but no deliveryof oil at OSV valves

Confirm specified unit can provide needed vertical discharge pressure

Check that all supply line connections are air andoil tight

Use adequate size supply line

Minimize supply line restrictions

Prime pump and purge supply lines of air

Check pump pressure settings

Oil delivery at OSV valves. but burners do not fire

Confirm specified unit can provide needed capacity(Size to firing rate for single pipe burners or size togear set capacity for two piped burners)

In pressurized system, adjust pressure to develop areading of 10-15 PSI at the most remote or highestburner

Page 137: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

132

In open loop system, install standpipe, back pressurevalve, vacuum breaker or over-sized drop pipe

Check to assure that pressures at OSV inlet does notexceed maximum of 60 PSI

Check for leaking or damaged OSV

Check for line failure between OSV and burner pump

Check burner for fuel pump failure or ignition problems

Burner pump seal damaged

Install OSV to assure pressure at burner pump doesnot exceed 3 PSI

Install pressure relief valve if entrapment condition issuspected

Pressure increases in supply line after shutdown

Check to assure that pressures at OSV inlet does notexceed maximum of 60 PSI

Install pressure relief valve if entrapment condition issuspected

OIL SAFETY VALVE PROBLEMS

Oil Safety Valve does not open

Too much pressure at inlet of valve

Flow exceeds recommended flow rate for valve.

Entrapment condition (expansion of oil in supply line)

Check for air leaks between the OSV valve and burnerpump

Page 138: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

133

MANUFACTURERS REPSWebster and its Representatives have the resourcesand technical background to answer any installation orservice questions you may have.

Please refer to the listing below for the W ebsterRepresentative near you.

SHANE MILLER STATESG. MILLER CO. IN / IL / MN / WI901 River Lane KY / ND / SDLoves Park, IL 61111Tele: 815-964-5692 Fax: 815-964-5770Cell: [email protected]

MONS KING STATESETC SALES, INC. DE / MD / VAPO Box 235 E.PA / NJPaoli, PA 19301Tele: 610-296-3527 Fax: 610-640-4271Cell: [email protected]

DON HOGAN STATESTRI-NATIONAL SALES OH / WV / W.PA / MI841 South Parkview DriveAurora, OH 44202Tele: 330-562-8920 Fax: 330-562-1586Cell: [email protected]

TOM JOHNS STATESTRADREP LTD OH / WV / W.PA / MI3801 Wiltshire RoadChagrin Falls, OH 44022 Tele: 440-247-3880 Fax: 440-247-3882

LENNIE DeANGELO STATESPILGRIM SALES ME / NH / MA18 Pilgrim Road CT / VT/ RIMarblehead, MA 01945Cell: 617-548-2813 Fax: [email protected]

GEORGE NIKIFOROV, INC INTERNATIONAL200 Park Ave., SouthSuite 514New York, NY 10003Tele: 212-473-4555 Fax: [email protected]

DON KNUTH STATESTSS ASSOCIATES INC NY19 Rustyville RoadAlbany, NY 12211Tele: 518-621-7283 Fax: [email protected]

Page 139: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

134

BILL GLUCKIN LONG ISLAND, NYCOMFORT ZONE SALES2870 Milburn Ave.Baldwin, NY 11510Tele: 516-442-0388 Fax: 516-442-0389Cell: [email protected]

CURTIS ZAHALKA INSIDE SALESWEBSTER FUEL PUMPS & VALVES219 Hahn RoadFrankfort, KY 40601Tele: 502-223-0025 Fax: 502-223-5629Toll Free: [email protected]@cctoolinc.comwww.websterfuelpumps.com

E.S. GALLAGHER SALES CANADA920 Caledonia RoadUnit 3BToronto, Ontario M6B 3Y1Tele: 416-789-5385 Fax: [email protected]

Page 140: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

135

NOTES

Page 141: Webster Service Technician’s Handbook - WEBSTER FUEL PUMPS

136

NOTES


Recommended