Ordering information
Specifications
W72×H72mm, Weekly/Yearly timer
Easy to check and change the program setting Customizable weekly or yearly unit time setting and control by user Includes daylight saving time function Built-in 2 independent control output (relay) Flush and surface mounting are in one unit Enable to mount on DIN rail with base plate
Model LE7M-2
Power supply 100-240VAC 50/60Hz
Allowable voltage range 90 to 110% of rated voltage
Power consumption Max. 4.2VA
RETURN input Short-circuit or open by switch or relay
Timing program 48 steps for weekly, 24 steps for yearly
Operation mode ON/OFF mode, cycle mode, pulse mode
Mounting Front panel, surface, DIN rail
Time deviation ±15sec./month(ambient temperature: 25) (±4sec. /week)
Temperature error ±0.01% ±0.05sec.(ratio by set time)
Memory protection Over 5 years(at 25)
ControlOutput
Contact type SPDT(Single Pole Double Throw)
Contact capacity 250VAC 10A resistive load
Output number Independent 2 output(1c × 2)
Relaylife cycle
Mechanical Min. 5,000,000 operations(switching capacity: 30 times/min)
Electrical Min. 50,000 operations<switching capacity: 20 times/min, 250VAC 10A(resistive load)>
Insulation resistance Min. 100MΩ(at 500VDC megger)
Dielectric strength 2000VAC 50/60Hz for 1minute
Noise strength ±2kV the square wave noise(pulse width: 1) by the noise simulator
Environ-ment
Ambient temperature -10 to 55, storage: -25 to 65Ambient humidity 35 to 80%RH
Unit weight Approx. 272g
Item
Size
Output
LE7 M 2
2 2 Relay outputs
M DIN W72×H7mm
LE7 Weekly/Yearly timer
Features
※Environment resistance is rated at no freezing or condensation.
Please read “Caution for your safety” in operation manual before using.
K-76
LE7M-2
N.C.
N.C.
N.C. N.C.
OUT2
OUT1 SOURCE
SOURCESOURCE
[Single phase] [Three phase]
COM
COM
COM COM
N.O.
N.O. N.O.Power of
singlephase
Load Load
MagneticSwitch
MagneticSwitch
Power ofthreephase
N.O.
RETURNINPUT
CONTACT OUT250VAC 10ARESISTIVE LOAD
100-240VAC50/60 4.2VA
6
1
7
2
8
3
9
4
10
5
1 12 23 34 45 5
Connections
Load connectionYou must connect a surge absorber to the both ends of the load to prevent from damage or malfunction of this unit when controlling non-resistive load (ex: magnetic switch, etc).
In case of controlling the load directly
In case of controlling the load by using a magnetic switch
S/A
: Surge AbsorberS/A : Surge AbsorberS/A
S/A
N.C.
SOURCEPower circuit forload operation
COM
N.O.
부부
1 2 3 4 5
Load
K-77
(A) Photoelectricsensor
(B) Fiberopticsensor
(C) Door/Areasensor
(D) Proximitysensor
(E) Pressuresensor
(F) Rotaryencoder
(G) Connector/Socket
(H)Temp.controller
(I)SSR/Powercontroller
(J) Counter
(K) Timer
(L) Panelmeter
(M)Tacho/Speed/ Pulsemeter
(N)Displayunit
(O)Sensorcontroller
(P)Switchingmode powersupply
(Q)Steppermotor&Driver&Controller
(R)Graphic/Logicpanel
(S)Fieldnetworkdevice
(T) Software
(U) Other
Weekly/Yearly Timer
86
6455
6476.5
DIN rail
67.6 9
55
958595 85
95
9.5
13.5 Panel67
4-M3 TAP
Base plate
7 60Min. 91
67.5
Min
. 91
72
① Unscrew 4 bolts from terminal block.
(Front panel mounting)
(Surface mounting)
② Detach terminal block from case and then rotate it 180 degree.
③ Assemble terminal block to case by using the 4 bolts.
Dimensions & Mounting
How to switch from the flush mounting to surface mounting type
(unit: mm)
68+0.7 0
68+0
.7 0
Remove terminals from the body after unscrewing terminal screws, and then assemble terminals to the body after rotating terminals as shown below.
1) Front panel mounting
2) Surface mounting
3) DIN rail mounting
Panel cut-out
Panel hole cut-out
Base Plate
K-78
LE7M-2
1
2
14
155
16
3
4
6
17
18
9
20
19
7
8
10
21
22
11
12
13
ON time OFF time
Parts description
Functions
1. Day indicator2. Day display Light : Day is selected. Light-out : Day is not selected.3. Current time setting mode indicator4. DST display(Daylight saving time)5. AM/PM display6. Season display7. Program display8. Display ON time/day, OFF time/day, ON time width, OFF time width 9. AM/PM display10. YEAR display: It turns ON when set, check, modify, delete yearly
program, set yearly holidays and operate yearly program.
11. Yearly START/STOP day display12. Main display
13. Remaining step display14. Operation mode display15. Power restore input display16. Output mode display17. Year, month, date display18. Unit of pulse width display19. Sub-display20. CHECK key21. MODE key22. Operation key23. Output selection switch AUTO : Control output according to the set program. ON : Output is ON.(Operation) OFF : Output is OFF.※Output 1(OUT1) and Output 2(OUT2) are selected
independently.24. SET key
Program setting and output operationOutput1/Output2 operates according to Program1 and Program2.
Definitions Record : A part of program that controls output operation. Step : Basic component of record.
Operation modesIf the operation mode of Program1(Program2) is set on pulse mode initially, the pulse mode is fixed for additional programs.If the operation mode of Program1(Program2) is set on ON/OFF or cycle mode initially, pulse mode cannot be used for additional programs.
Weekly ON/OFF modeOutput operation by ON/OFF set time.• Min. time setting unit : 1 min.• It is able to set ON/OFF day separately.• One record in two Steps(ON day/ON time, OFF day/OFF
time)
Weekly Cycle modeOutput turns ON for ON time and turns OFF for OFF time. And the ON/OFF cycle is repeated.
23
24
K-79
(A) Photoelectricsensor
(B) Fiberopticsensor
(C) Door/Areasensor
(D) Proximitysensor
(E) Pressuresensor
(F) Rotaryencoder
(G) Connector/Socket
(H)Temp.controller
(I)SSR/Powercontroller
(J) Counter
(K) Timer
(L) Panelmeter
(M)Tacho/Speed/ Pulsemeter
(N)Displayunit
(O)Sensorcontroller
(P)Switchingmode powersupply
(Q)Steppermotor&Driver&Controller
(R)Graphic/Logicpanel
(S)Fieldnetworkdevice
(T) Software
(U) Other
Weekly/Yearly Timer
ON time
ON Time
ON width
Pulse width(1 to 59sec., 1 to 60min.)
OFF time
OFF width
Weekly setting 1 of Program1
Weekly setting 2 of Program1
Yearly setting 1 of Program1
Program1 mode
① ② ③ ④ ⑤ ⑥
Yearly ON/OFF mode Output turns ON at ON time on START date and turns OFF at OFF time on STOP date.• One record in three steps(START/STOP date, ON/OFF
time) Yearly pulse mode Output turns ON at ON time on START date and turns OFF at OFF time on STOP time for a specified pulse width repeatedly.(Pulse width : 1 to 59sec., 1 to 60min.).• One record in three steps(START/STOP date, ON time,
pulse width)
Program operation
① to ② : Operated by weekly setting 1 of Program 1. ② to ③ : Operated by weekly setting 2 of Program 1. ④ to ⑤ : Operated by weekly setting 1 of Program 1. ⑤ to ⑥ : Operated by yearly setting 1 of Program 1.
(During weekly program operation at 12:00 AM on START date, the weekly program operation stops, and it changes to yearly program operation mode. The yearly program operation stops at 12:00 AM on the next day of STOP date.)
Display and change of next mode The day of next mode in Program1 or Program2 is displayed on the day indicator, and the time of next mode is displayed on the lower row of screen. Press +
in RUN mode it is changed from program1 to program2 or from program2 to program1. In ON/OFF operation mode, set ON time and OFF time
to next mode. In Pulse operation mode, set Pulse ON time to next mode.
Power restore modeIn setting group 2-Level 2(Power restore), select auto [AT]or normal [NOR] by or key, and press key to set. Auto [AT] power restore modeOutput(OUT1, OUT2) operates according to program when power turns on again after power failure. Normal [NOR] power restore modeWhen power turns on again after power failure, output is kept OFF and RET.IN flashes on the panel. When power restore input is detected, RET.IN turns off and output operates according to program.• Power restore inputInput contact signal in external "Return input terminals (⑨ to ⑩)" by switch or relay, or press key for 3sec. in RUN mode.Please use reliable contacts enough to flow 0.1mA of current at 5VDC when use switch or relay.
Season switching modeThis feature uses for setting seasonal weekly operation mode.To operate this mode, save starting month and date, ending month and date of each season which displays S1, S2, S3, S4 then set day and time of each season in weekly program setting. It is also able to operate only in summer and winter season. (S1: set summer season, S2: set winter season, S3/S4: do not set)At the season switching selection LEVEL 2 status in setting 2 group (SEN turns ON, OFF flashes), select ON [ON] by pressing or key and press key to complete the season switching. Be sure that if changing season switching from OFF to ON or, ON to OFF, the weekly program 1(P1) and the weekly program 2 (P2) which are set before are deleted. ON [ON] modeWeekly program is switched automatically by season switching.• Period setting per season① At the season switching selection LEVEL 2 status in
setting 2 group (SEN flashes, the set season turns ON, START and STOP turn ON), press key.
② Advance to the flashing position of season selection among S1, S2, S3, S4 by or key and press key.
③ After set START month, date per season and press key.
④ key is pressed after set STOP month, date per season, it is advanced to LEVEL1 of period setting per season. Add or adjust the period setting by key.
It is disable to use when it is OFF [OFF]. If season terms are overlapped, these are prioritized in
S4>S3>S2>S1 order.
• Set range for ON/OFF time width : 1min. to 12 hour 59min. • One record in 3 steps(ON day/ON time, OFF day/OFF
time, ON time width/OFF time width)
Weekly pulse mode Output turns ON at ON time for a specified pulse width.(Pulse width : 1 to 59sec., 1 to 60min.)• One record in two steps(ON day/ON time, pulse width)
K-80
LE7M-2
Daylight saving timeTo utilize daylight during the summer season, daylight saving time is adjusted forward one hour from standard time. In setting group 2-LEVEL 2(DST turns ON, AT or NOR flashes.), select Auto [AT] or Normal [NOR] by or key and press key to set. Auto[AT] Daylight Saving Time modeCurrent time will be faster as an hour when it is started and slower as an hour when it is finished.• Automatic Daylight Saving Time period setting① Automatic Daylight Saving Time period setting LEVEL 1
of setting group 2. (DST flashes and START and STOP turn ON.)
② Set START date(Month, date) of automatic Daylight Saving Time mode and press key.
③ Set START time(AM/PM, Hour) of automatic Daylight Saving Time mode and press key.But, the minute will be fixed as 00.
④ Set STOP date(Month, date) of automatic Daylight Saving Time mode and press key.
⑤ Set STOP time(AM/PM, Hour) of automatic Daylight Saving Time mode and press key. But, the minute will be fixed as 00.
Normal [NOR] daylight saving time modePress key over 3sec. in RUN mode, +1h turns ON and current time is faster as an hour and +1h turns ON out or vice versa, when press key over 3sec. again.
Current time setting(Ex) Set the current time as 10, Mar, 2008, 5:10 PM.
SUN MON TUE WED THU FRI SAT
① Advance to the current time setting mode
+ keys are pressed over 3sec. in RUN mode, it is advanced to current time setting of setting group 2 and clock will be flashed and tAJ will be lighted in second display part, press key.
SUN MON TUE WED THU FRI SAT
② Year, month, date setting
Press or key to set 08 (year 2008) and move the flashing digit to position month by key.Press key after press or key to set date 10.
SUN MON TUE WED THU FRI SAT③ Current time(AM, PM) setting
Press or key to select PM and move the flashing digit to position hour by key.
SUN MON TUE WED THU FRI SAT
④ Current time(Hour, Min.) setting
Press or key to set 5 PM and move the flashing digit to position min. by key. Press or key to set 10min. and press key and it is returned to RUN mode when press
key over 3sec.
It advances to "①Current time setting mode" in ON status and set current time as shown above ② to ④ by
key. Current time is set up to 31, Dec., 2099. Check current year/month/date in RUN mode When
key is pressed over 3sec. in RUN mode, it advances to current year/month/date display. After display current year/month/ date for 3sec., it returns to RUN mode displaying current display.
K-81
(A) Photoelectricsensor
(B) Fiberopticsensor
(C) Door/Areasensor
(D) Proximitysensor
(E) Pressuresensor
(F) Rotaryencoder
(G) Connector/Socket
(H)Temp.controller
(I)SSR/Powercontroller
(J) Counter
(K) Timer
(L) Panelmeter
(M)Tacho/Speed/ Pulsemeter
(N)Displayunit
(O)Sensorcontroller
(P)Switchingmode powersupply
(Q)Steppermotor&Driver&Controller
(R)Graphic/Logicpanel
(S)Fieldnetworkdevice
(T) Software
(U) Other
Weekly/Yearly Timer
RUN mode RUN mode
SET SET
Press MODE keyfor 3sec.
Press MODE keyfor 3sec.
Press MODE keyfor 3sec.
Press MODE + SET keyfor 3sec.(Setting group 1)
※1
※2
(Setting group 2)
Program1 weekly programsetting mode(PROG P1 flashes)
Program1 weeklyprogram setting
Current time setting mode(Clock icon flashes)
Power failure return selection mode (RET flashes,
AT or NOR turns ON)
Season switching selection mode(SEN flashes,
ON or OFF turns ON)
Period setting for season mode(SEN flashes, period-set
season turns ON andSTART or STOP turns ON)
Daylight saving time mode(DST flashes,
AT or NOR turns ON)
Automatic[AT] daylightsaving time period
setting mode [DST] flashes,START or STOP turns ON)
Current timesetting
Power failurereturn selection
Season switchingselection
Period settingper season
Daylight savingtime selection
Automatic daylightsaving time period setting
Program2 weekly programsetting mode(PROG P2 flashes)
Program2 weeklyprogram setting
Program1 Yearly programsetting mode
(PROG P1, YEAR flash)
Program2 yearly programsetting mode
(PROG P2, YEAR flash)
Program1 weekly programdelete mode
(PROG P1, CLR flash)
Program1 weekly programdelete mode
(PROG P2, CLR flash)
Program1 yearly programdelete mode
(PROG P1, YEAR, CLR
flash)
Program2 yearly programdelete mode
(PROG P2, YEAR, CLR
flash)
Weekly day change mode(cDY flashes)
Yearly holiday operation mode(hDY, YEAR flash)
Program1 yearlyprogram setting
Program2 yearlyprogram setting
All Program1 weeklyprogram delete
All Program2 weeklyprogram delete
All Program1 yearlyprogram delete
All Program2 yearlyprogram delete
Standard day,change day setting
Yearly holidayoperation mode setting
Program setting Setting group 1 Setting group 2
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1LEVEL2
SET SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
When it advances to setting group 1 in RUN mode, output (OUT1, OUT2) will be OFF.
It returns to previous setting group 1 when power of time switch is ON again in setting group 1.
When MODE key is pressed in LEVEL2 of setting group 1, current setting will be canceled and it returns to previous LEVEL1.
※1: Season switching selection is OFF.※2: Automatic switching selection of Daylight Saving Time
is Normal [NOR]. When it advances to setting group 2 in RUN mode,
output (OUT1, OUT2) will be OFF. When power of time switch is ON again in setting group 2,
it returns to previous setting group 1. Front MODE key is pressed in LEVEL2 of setting group 2,
it returns to previous LEVEL1. When season switching selection is changed from OFF
to ON or ON to OFF, previous set weekly program will be deleted.
K-82
LE7M-2
SUN MON TUE WED THU FRI SAT
8:00AM
8:00AM
8:00AM
8:00AM
8:00AM
6:10PM
6:10PM
6:10PM
6:10PM
6:10PM
8:00AM
8:00AM
8:00AM
8:00AM
8:00AM
8:00AM
ON for 10sec.
8:00 AM
Weekly program setting Weekly ON/OFF mode(Ex) Output1(OUT1) is ON from Monday to Friday at 8:00 AM and OFF at 6:10 PM.
Weekly pulse modeOutput2(OUT2) is ON for 10sec. at 8:00AM from monday to friday during S2 season in case, period of S1, S2, S3, S4 is set.
① Advance to program1(P1) weekly program setting mode
MODE key is pressed over 3sec. in RUN mode, PROG P1 flashes and press SET key.
SUN MON TUE WED THU FRI SAT
② Mode type setting
Press SET key in ON/OFF mode.
SUN MON TUE WED THU FRI SAT
③ ON day setting
Press key to move the indicator to monday, it will be lighted when or key are pressed and move it to tuesday by key.Press SET key after tuesday, wednesday, thursday, friday turn ON.
SUN MON TUE WED THU FRI SAT
④ ON time setting(AM, PM)
key is pressed, move the flashing to hour position and select PM by or key when ON time is afternoon.
SUN MON TUE WED THU FRI SAT
⑤ ON time setting(Hour, Min.)
Set 8:00 by or key and press SET key.
SUN MON TUE WED THU FRI SAT
⑥ OFF day setting
Press SET key to check ON/OFF day.
SUN MON TUE WED THU FRI SAT
⑦ OFF time setting(AM, PM)
Select PM by or key and move the flashing to hour position by key.
SUN MON TUE WED THU FRI SAT
⑧ OFF time setting(Hour, Min.)
Move the flashing to minute position after set 6:00 by or key and set the minute as 10 and press SET key.
SUN MON TUE WED THU FRI SAT
⑨ Complete to set
Press SET key to set additional program.
SUN MON TUE WED THU FRI SAT
① Program2(P2) advance to weekly program setting mode
MODE key is pressed for 3sec.in RUN mode, PROG P1 is flashed and press MODE key again, PROG P2 flashes and press SET key.
SUN MON TUE WED THU FRI SAT
② Mode type setting
Press or key when ON /OFF flashes, Pulse flashes and press SET key.
SUN MON TUE WED THU FRI SAT
③ Season selection
Press or key to select season S2 and press SET key.
SUN MON TUE WED THU FRI SAT
SUN MON TUE WED THU FRI SAT
K-83
(A) Photoelectricsensor
(B) Fiberopticsensor
(C) Door/Areasensor
(D) Proximitysensor
(E) Pressuresensor
(F) Rotaryencoder
(G) Connector/Socket
(H)Temp.controller
(I)SSR/Powercontroller
(J) Counter
(K) Timer
(L) Panelmeter
(M)Tacho/Speed/ Pulsemeter
(N)Displayunit
(O)Sensorcontroller
(P)Switchingmode powersupply
(Q)Steppermotor&Driver&Controller
(R)Graphic/Logicpanel
(S)Fieldnetworkdevice
(T) Software
(U) Other
Weekly/Yearly Timer
④ ON day setting
Press key to move the indicator to Monday, it will be lighted when or key is pressed and move it to Tuesday by key.Press SET key after light Tuesday, Wednesday, Thursday and Friday.
SUN MON TUE WED THU FRI SAT
Press key, move the flashing to hour position and select PM by or
⑤ ON time setting(AM, PM)SUN MON TUE WED THU FRI SAT
Set 8:00 by or key and press SET key.
⑥ ON time setting(Hour, Min.)SUN MON TUE WED THU FRI SAT
Press or key to select pulse duration as 10s and press SET key.
⑦ Pulse width settingSUN MON TUE WED THU FRI SAT
Press SET key to set additional program.
⑧ Complete to setSUN MON TUE WED THU FRI SAT
6:00 AMStart Cycle mode
5:30PM
ON for 10min.
OFF for 5min.
Weekly cycle mode(Ex) Output1(OUT1) is ON for 10min and OFF for 5min from monday 6:00AM to saturday 5:30PM.
SUN MON TUE WED THU FRI
SAT
① Advance to program1(P1) weekly program setting mode
In RUN mode, press MODE key for 3 sec. and PROG P1 flashes. Press SET key.
SUN MON TUE WED THU FRI SAT
③ to ⑧Refer to ③ to ⑧ of "Weekly ON/OFF mode" to set ON day, ON time, OFF day and OFF time.
② Mode type setting
Press or key when ON/OFF flashes, CYCLE flashes and press SET key.
SUN MON TUE WED THU FRI SAT
⑨ ON time width setting
Press key to move the flashing to minute position and set as 10min. by or
key and press SET key
SUN MON TUE WED THU FRI SAT
⑩ OFF time width setting
Press key to move the flashing to minute position and set as 5min. by or key and press SET key.
SUN MON TUE WED THU FRI SAT
⑪ Complete to set
Press SET key to set additional program.
SUN MON TUE WED THU FRI SAT
K-84
LE7M-2
Yearly holiday modeIt operates to off the output without program adjustment during previously set yearly holiday period available from present year to 31, Dec. of the next year. Designate the start date of yearly holiday and year of end date as every year [--] to repeat the holiday mode for specified in every year.
Setting exampleSet every year 5, May to off the output(OUT1, OUT2).
① Advance to weekly day change mode
Press MODE key over 3sec. to move to the setting group1 in RUN mode and press it repeatedly until cDY is flashed in second display part and press SET key.
SUN MON TUE WED THU FRI SAT
Press key until month position flashes and set May by or key and press key until date posi-tion flashes. Press SET key after set 5th by key.
③ Start date of yearly holiday settingSUN MON TUE WED THU FRI SAT
The flashing is moved to month position directly and press or key to set May and press key until date position flashes.Press SET key after set 5th by or key.
④ End date of yearly holiday settingSUN MON TUE WED THU FRI SAT
Press MODE key to finish theadditional yearly holiday setting and press SET key to set .※It is able to set yearly
holiday up to 12 times.
⑤ Complete to yearly holidaySUN MON TUE WED THU FRI SAT
② Standard day selection
Press key to move the indicator to saturday and press SET key. after select saturday as standard day (Sat turns ON) by or key.
SUN MON TUE WED THU FRI SAT
③ Change day selection
Press key to move the indicator to monday and select monday to change (Mon turns ON) by or
key and repeat the procedure to select tuesday to change (Tue turns ON) and press SET key to complete.
SUN MON TUE WED THU FRI SAT
① Advance to yearly holiday mode
Press MODE key over 3sec.to move to the setting group1 in RUN mode and press it repeatedly until hDY flashes in second display part and press SET key.
SUN MON TUE WED THU FRI SAT
② Yearly holiday No. display
Press SET key after check yearly holiday No.
SUN MON TUE WED THU FRI SAT
Weekly day changeIt operates when the specified day mode is required to install in other day from the set day and it returns to previous program setting automatically when it is finished. It is applied to program1(P1) and program2(P2). Weekly day change cancellation① Change current year, month, date in current time setting
mode② Change standard day③ Delete all program in program1(P1) and program2 (P2)④ Season switching Setting exampleOutput1(OUT1) is ON in Saturday at 9:00AM and OFF at 12:00PM and it is ON 8:30AM and OFF at 6:00PM from Monday to Friday and the mode of Monday and Tuesday is operated temporarily as Saturday(standard) program.
K-85
(A) Photoelectricsensor
(B) Fiberopticsensor
(C) Door/Areasensor
(D) Proximitysensor
(E) Pressuresensor
(F) Rotaryencoder
(G) Connector/Socket
(H)Temp.controller
(I)SSR/Powercontroller
(J) Counter
(K) Timer
(L) Panelmeter
(M)Tacho/Speed/ Pulsemeter
(N)Displayunit
(O)Sensorcontroller
(P)Switchingmode powersupply
(Q)Steppermotor&Driver&Controller
(R)Graphic/Logicpanel
(S)Fieldnetworkdevice
(T) Software
(U) Other
Weekly/Yearly Timer
② Mode type setting
or key is pressed when ON/OFF flashes to set pulse mode and press SET key.
SUN MON TUE WED THU FRI SAT
③ Start date setting
Press or key twice to set 08(year 2008) and move to month position by key.Set Oct. by or key and move to date position by
key and press SET key after set 2nd by or key.
SUN MON TUE WED THU FRI SAT
④ End date setting
The flashing is moved to month position directly by
key and set 4th by or key after move it to date
position by key, then press SET key.
SUN MON TUE WED THU FRI SAT
④ End date setting
The flashing is moved to month position directly and press or key to set April and press or key until date position flashes.Press key after set 7th by SET key.
SUN MON TUE WED THU FRI SAT
⑤ ON time setting(AM, PM)
key is pressed, move the flashing to hour position and select PM by or key when ON time is afternoon.
SUN MON TUE WED THU FRI SAT
⑥ ON time setting(Hour, Minute)
Press or key to set 9 and press SET key after check 00min.
SUN MON TUE WED THU FRI SAT
⑦ OFF time setting(AM, PM)
Select PM by or key and move the flashing to hour position by key.
SUN MON TUE WED THU FRI SAT
⑧ OFF time setting(Hour, Minute)
Move the flashing to minute position after set 5:00 by or key and set the minute as 10 and press SET key.
SUN MON TUE WED THU FRI SAT
⑨ Complete to set
Press SET key to set ad-ditional program.
SUN MON TUE WED THU FRI SAT
2, Oct 3, Oct 4, Oct
8:00AM
8:00AM
8:00AM
ON for 5sec.
10:00AM
Yearly pulse mode(Ex)Output2(OUT2) is ON from 2, Oct, 2008 to 4, Oct, 2008 at 10:00AM and OFF after 5sec. (Present is 2007.)
① Advance to program2(P2) yearly program setting mode
MODE key is pressed for 3sec.in RUN mode, PROG P1 is flashed and press MODE key again, PROG P2 YEAR is flashed and press SET key.
SUN MON TUE WED THU FRI SAT
Yearly program setting Yearly ON/OFF mode(Ex) Output1(OUT1) is ON from every 5, Apr to 7, Apr at 9:00AM and OFF 5:10PM.
① Advance to program1(P1) yearly program setting mode
Press MODE key for 3sec. in RUN mode, PROG P1 is flashed and press MODE key 3 times more until PROG P2 YEAR flashes and press SET key.
SUN MON TUE WED THU FRI SAT
② Mode type setting
Press SET key when ON/OFF flashes.
SUN MON TUE WED THU FRI SAT
③ Start date setting
Press key until month po-sition flashes and set April by or key and press
key until date position flashes. Press SET key after set 5th by or key.
SUN MON TUE WED THU FRI SAT
K-86
LE7M-2
RUN mode
Program1 Yearly programrecord No.1 [r01]
setting check
Program1 Yearly programrecord No.1 [r01] setting
modify and delete
Program1 Yearly programrecord No.2 [r02] setting
modify and delete
Program2 Yearly programrecord No.1 [r01] setting
modify and delete
Program1 Yearly programrecord No.2 [r02]
setting check
Program2 Yearly programrecord No.1 [r01]
setting check
CHECK
CHECK
CHECK
Yearly program check, modify and delete
※YEAR turns ON when check, modify or delete yearly program.
If any key is untouched for 60sec, it is returned to RUN mode in weekly or yearly program check.
In weekly or yearly program check, it controls output according to program setting and output is OFF in modify or delete mode.
When MODE key is pressed in weekly or yearly programrecord modify, delete stand by or delete mode, current work is cancelled and it is returned to check mode.
Weekly or yearly program record modify and delete(1) Program record modify① When press SET key over 3sec. in program check, EDT
flashes in second display part, press SET key.② It returns to check mode when finish the modify same
as the above procedure.(2) Program record delete① When press SET key over 3sec. in program check, EDT
flashes in second display part, press or key until CLR flashes in second display part and press SET key.
② Press CLR key over 3sec. when SET turns ON in second display part, it returns to program check.
RUN mode
Program1 weekly program record No.1 [r01]
setting check
Program1 weekly program record No.1 [r01] setting
modify and delete
Program1 weekly program record No.2 [r02] setting
modify and delete
Program2 weekly program record No.1 [r01] setting
modify and delete
Program1 weekly program record No.2 [r02]
setting check
Program2 weekly program record No.1 [r01]
setting check
Program check, modify and delete
Press CHECK key for 1sec.
CHECK
CHECK
CHECK
Weekly program check, modify and delete
Press MODE keyfor 3sec.
Press SETkey for 3sec.
Press SETkey for 3sec.
Press SETkey for 3sec.
Press CHECK key for 1sec.
Press MODE keyfor 3sec.
Press SETkey for 3sec.
Press SETkey for 3sec.
Press SETkey for 3sec.
※It is able to set year of start/end date in yearly program setting up to 2 years later from the present year.
key is pressed, move the flashing to hour position and select PM by or key when ON time is afternoon.
⑤ ON time setting(AM, PM)SUN MON TUE WED THU FRI SAT
⑧ Complete to set
Press SET key to set additional program.
SUN MON TUE WED THU FRI SAT
⑦ Pulse width setting
Press or key 4 times to select pulse width as 5s and press SET key.
SUN MON TUE WED THU FRI SAT
⑥ ON time setting(Hour, Minute)
Press or key twice to set 10 and press SET key after check 00min.
SUN MON TUE WED THU FRI SAT