HYSYS SIMULATION PROJECT

100 MTPD HYDROGEN PEROXIDE (50%) PLANT

Page 3: WELCOME

A hydrogen peroxide plant is to be set-up at Gazaria, Munshiganj having a capacity of 100 metric ton of hydrogen per oxide (50 % w/w) per stream day, corresponding to 33,000 metric ton of hydrogen peroxide(50% w/w) per year, including all off sites, auxiliaries, utilities and supporting facilities using natural gas as feedstock and fuel.

DEFINITION OF THE PLANT

Page 4: WELCOME

NG from TITAS Gas◦ Methane > 96 % (V/V)◦ Calorific Value > 1000 Btu◦ Pressure > 240 kPa◦ Temperature about 5-15 oC

Air Water

SPECIFICATION OF RAW MATERIALS

Page 5: WELCOME
Page 6: WELCOME

H2O2 specification:

H2O2 content 50% Free acid (as H2SO4) 0.040% max. Non-volatile matter 0.080% max. Stability 97.0% min. Freezing point -52.2°C Boiling point 113.8°C Density 1191 kg/m3

SPECIFICATION OF PRODUCT

Page 7: WELCOME

By Auto-oxidation of alkylanthraquinones By Electrolysis from Ammonium Bisulfate. From Barium Peroxide By oxidization of isopropanol

Auto-oxidation of 2-ethylalkylanthraquinone is selected for this project.

PROCESS SELECTION

Page 8: WELCOME

Geological Data

Location The site for the plant is selected on the bank of river

Meghna at Baluakandi under Gazaria upzilla in Munshiganj district.

Load bearing capacity: The soil has a bearing capacity of 0.38 ton/ft2 required piling is used.

Corrosive tendency: Non Corrosive

DESIGN BASIS

Page 9: WELCOME

Climatic condition

Dry bulb temperature (maximum) 35 oC (summer) Dry bulb temperature (maximum) 26 oC (winter)

Wet bulb temperature (maximum) 29 oC (summer) Wet bulb temperature (maximum) 22 oC (winter)

DESIGN BASIS (Contd.)

Page 10: WELCOME

Meteorological condition

Average monthly Temperature 35oC (max.) Average Temperature 30oC Average annual rainfall 2850 mm Wind flow

Direction = South to NorthVelocity = 52 mile/h

DESIGN BASIS (Contd.)

Page 11: WELCOME

Utility Electric Power

◦ Voltage 380/220 V◦ Frequency 50 Hz◦ Phase 3 phases

Cooling Water Inlet Outlet

Temperature < 30 oC 38 oCPressure 0.5 MPa 0.2 MPaTurbidity ≤ 50 mg/lChlorine < 5 ppm

PH 6.5 – 8

DESIGN BASIS (Contd.)

Page 12: WELCOME

Four main stages involved:

1. Hydrogen Generation ( Reformer)

2. Hydrogenation

3. Oxidation

4. Extraction and Purification

PROCESS INVOLVED

Page 13: WELCOME

A. Reformer: CH4+H2O = CO+3H2 - Q CO + H2O = CO2+H2 + Q

B. Hydrogenation And Oxidation tower:

REACTIONS INVOLVED

Page 14: WELCOME

PROCESS BLOCK DIAGRAM

REFORMERPRESSURE

SWINGADSORBER

HYDROGENATION TOWER

OXYDATIONTOWER

EXTRACTIONTOWER

SEPARATOR

DSV

PURIFICATIONTOWER

H2O2

STORAGETANK

Tail Gas

SEPARATOR

NG

Steam Tall Gas

Water WS

Make Up

DRYING TOWER

Air

Tail Gas

Water

WS STORAGE

TANK

Page 15: WELCOME

PROCESS FLOW DIAGRAM

Page 16: WELCOME
Page 17: WELCOME
Page 18: WELCOME

Natural Gas Knock Out Drum Feed Gas Compressor Desulfurization Vessel Desulfurization Vessel Water Tank BFW Pump Stack Heat Exchanger Waste Heat Boiler Reformed Gas Cooler Raw Gas Separator Pressure Swing Adsorber Induced Draft Fan Reformer

EQUIPMENT LIST

Page 19: WELCOME

Static Mixer Hydrogenation Tower Working Solution Pump Working Solution Storage Tank Hydrogenated Solution Storage Tank Hydrogenated Solution Pump Hydrogenated Solution Cooler Air Compressor Oxidation Tower Oxidation Solution Separator Tail Gas Condenser Oxidation Solution Cooler Wet Gas Separator

EQUIPMENT LIST (Contd.)

Page 20: WELCOME

Extraction Column Working Solution Separator Recycled Working Solution Pump Extraction Water Pump Recycled Working Solution Heater Purification Column Hydrogen Peroxide Storage Tank

EQUIPMENT LIST (Contd.)