Welcome to The Alpha Group
Presentation
by Ozcan Akbaba/ATTR/21/01/15
Total Power Solutions™ for:
• Communications Networks
• Traffic & Transportation
• Security & Public Safety
• Industrial & Utilities
• Renewable Energy
• Medical & OEM
• Smart Grid
ME Referances
AC Power Solutions
INDOOR 1P/3P Stand Alone UPSs
Modular UPSs
1P/3P STS
OUTDOOR
1P Rugged UPSs
CONTINUITY 1/3/6/10KVA
• True Online operation
• Zero transfer time in the event of a power disruption
• Models from 1 kVA up to 10 kVA
• High output PF 0.8 up to 3 kVA, 0.9 at 6 and 10kVA model
• Ideal for mission-critical applications: servers, voice and data networks
• Fully digitized microprocessor controlled
• Power factor correction
• SNMP internal slot included for web agent
• Extended battery connector included
• USB/RS232 interface
• Tower/Rackmount convertible design
• Up to 4 units in parallel (6 and 10kVA)
Example of an Outdoor Power System Enclosure
Battery heater mat
Gel batteries Outdoor AC UPS
(-40C to +74C)
Mounting bracket
Battery Charge Management System Transfer switch
X33 HE/HIP UPS / 10-1000KVA • Three phase input, three phase output
• True Online operation, IGBT rectifier technology
• Transformerless Technology
• High Efficiency up to 96.5% in online mode
• Output Power Factor 0.9
• THDI < 3%
• Zero transfer time
• Ideal for mission-critical applications
• Models available from 10kVA to 120kVA
• Fully digitized microprocessor controlled
• Power factor correction 0.99
• SNMP internal slot included for web agent
• Installation in parallel mode up to 8 units
Tri Power X33 HE uses online double conversion (VFI) technology where the load is always powered by the inverter ensuring a
filtered and stabilized sinusoidal voltage manufactured with the state of the art IGBT rectifier technology. Offering high efficiency
values up to 96.5% even in part load situations saves money on electricity bills protecting at the same time our enviroment with less
CO2 consumption. Light weight and small footprint allows easy, space saving and low cost installation. The 0.9 output power factor
provides up to 15% more active power than a traditional UPS and more load expansion. TRI X33 HE UPS systems are ideal for the
protection of critical information and telecommunications networks which can not run the risk of being powered from a poor quality
electrical supply.
8/62
Modular INDOOR/ HP SERIES 10-160
Flexibility
Power Sharing
N+X Redundancy
Power and Autonomy Scalability
Easy Management, Service and Maintenance
Modular Architecture :
Thanks to the
innovative
architecture, the Tri
Power X33 Mod
can adapt it self to
any kind of
electrical
connection.
Flexibility
Thanks to the innovative
architecture, the Tri Power
X33 Mod can adapt it self
to any kind of electrical
connection.
AMPS80 Alpha Modular Power System 80HP
High performance AC or hybrid AC/DC backup power system
99.999% reliability for mission critical indoor applications
48VDC BUS for Telecom
AMPS80 utilizes hot swappable 2.5k VA/ 2.0k W inverter
modules & optional 2/4kW rectifier modules
Ultimate flexibility, scalability and low MTTR
Intelligent system controller with integrated SNMP for local and
remote management of AC & DC power modules, batteries, and
other peripherals such as Battery Management Modules
15 year Design Life, >200,000 hours of MTBF and 98/94%
Efficiency mean low TCO
Small footprint system – up to 75kVA/ 60kW in a single 19” wide
box bay rack
frees up valuable rack space
AMPS80
AMPS80 Features & Benefits contd. 5. Integrated, Intelligent Controller with SNMP/ Ethernet
o Monitor/ manage both AC & DC power modules & peripherals locally
and remotely (via web pages)
o Lower training/ personnel costs
o Easy to use graphic LCD display
o CANBus protocol for highly reliable communication
One ‘master brain’ to manage AC & DC power systems & peripherals!
DC/ DC Converters
Integrated, Intelligent
Controller
Battery Monitoring AMPS Inverters/ UPS
Rectifiers
Highly Reliable Technology
• With TSI technology, each inverter module acts like an individual UPS and
can separate itself from the system, in case of failure
• Hence, TSI eliminates the need for Static Transfer Switch (STS), which, in
traditional double-conversion systems, is often the single point of failure
• Moreover, there is no transfer time when the module switches from AC to DC
mode
Traditional UPS Assembly
AMPS
Inverters
AMPS System with TSI Inverter Modules
DC Power Solutions
INDOOR Central Office DC PSs (400-10000A )
Small Office DC PSs(100-400A)
Cell Sites DC PSs(1-100A)
OUTDOOR Cell Sites DC PSs(1-100A)
DAS (1-50A)
Line Powering (1-5A)
FTTx Powering(1-3A)
48V / 360A
TT-18 kW
ERICSSON
BATTERY CABINET
48 V/1350 A
VODAFONE 1350 A /48V
VDF 2000A DC PS
VDF -2000/4000A
VDF-80KVA Single/Three ph-Inverter
Wataniya Telecom–Kuwait-6000A /48V
MOI-QATAR ( 2N ) 2X72KW
Installed base
Strong experience in cellular networks
> 250.000 BTS installed
Cordex CXPS 48-300W – Standard 1 RU, 19” Shelf
Shelf p/n 0300072
o 1RU 19” - 3 module shelf
o Mechanicals
• mm: 43H (1U) x 440W x 250D
• In: 1.75H x 17.3W x 9.45D
• Weight: 2kg (6.6lb)
Electrical
o AC Input: 90 to 265 Vac, single phase
o Input current (per module)
• 1.4A @ 230Vac
• 3A @ 110Vac
• 3.7A @ 90Vac
o Output voltage: 43-58Vdc
o Power output: 300W per module
2RU Front Access Shelf
Up to (4) 1.2kW Rectifiers; 100A Max @ 48Vdc 2RU High, 19/23” Universal Rack Mount Complete Front Access Connections CXCM1 Controller (Modular CXCi) Battery LVD and Battery Shunt (2) IEC AC Line Cord Connections (2) Battery Connections Distribution Module
o (4) Plug-In Breakers
o (10) GMT Fuses
1RU Bulk Power Shelves
030-835: Up to (4) 1.2kW Rectifiers; 100A Max @ 48Vdc 030-845: Up to (5) 1.2kW Rectifiers; 125A Max @ 48Vdc 1RU High, 19/23” Universal Rack Mount Rear Access Connections CXCM1 Controller (Modular CXCi) IEC AC Line Cord Connections Bus Bar Output w/ 3/8”-1”C Connex Shelf: 1.75”H x 17.3”W x 12”D System: 5.3”H x 17.3” W x 15”D
Shelf Type DC System-TT-DSLAM
Project
TT-NATO-TAFICS
Enclosure Solutions for oDAS Applications
Monitoring
Comp@s & Arm@da
Topology
Energy systems for cellular base stations
Non-system variables can be measured
Site management through Comp@s communication card
Remote Site 1
Arm@da
DB
DB
Remote Site 2
DB
Comp@s Comp@s
Measured parameters
RF module 3
System module
Rectifier Site power input
Battery • cooling
• other
230V - AC 48V - DC
Site support system
RF module 2
RF module 1
Client Interface Overview
FTTx Networks
The core of voice, data and video transmission is fiber, but electronics is still needed to translate sounds and images into pulses of light for transmission and back again to electronics for hearing and viewing. The electronics would always require a reliable sources of DC power.
“Who will provide this power, and
where will it be located?”
ONU – Optical network Unit (multi premise)
ONT – Optical Network Terminal (single premise)
deployment
Under test/evaluation
Competitors
No firm plans yet
Fiber to the home, no need for power
N°1 position in W-Europe DSL/Broadband
networks
> 50% of European market access networks
Several examples: Deutsche Telekom Germany
NTG 2005
+/- 15 kpcs
NTG 2007
+/- 8 kpcs (4100 + 3550)
Deutsche Telekom Germany
NTG 2005
+/- 15 kpcs
NTG 2007
+/- 8 kpcs (4100 + 3550)
Belgacom Belgium
Different systems
– Local Powering
• 2 x 400W > 20.000 deployed
• 3 x 400 W for All IP application +/- 1.000 deployed
• 2 x 140 W FO application +/- 1.000 deployed
Battery mgt
Monitoring Rectifier Rectifier Rectifier
Outputs
Fan
PT Portugal
Remote Powering2 x 60W
2 x 600W
OTE Greece
Remote Powering 3 x 120W
OTE Greece 1U, 2 x 850W KPN Netherlands
Output breakers
4x30A 2x6A
Output breakers
4x30A 2x6A
Battery connector &
breaker 80A
Battery connector &
breaker 80A
Output connectors 6xOutput connectors 6x
Up to 4 x 850W CAR0948TN rectifiersUp to 4 x 850W CAR0948TN rectifiers
> 4.000 deployed
Line Powering
• A means of energizing remote equipment from a centralized location
over outside plant (OSP) over telecom twisted copper cable
• Also known as remote power, network power, centralized power, span
power
• DC-DC Converters are used to convert from a standard 48V system to a high DC voltage, transmitted over multiple copper power pairs, and down-converted back to 48VDC at the load equipment end.
• Used for decades in telecom networks for various tasks, such as the coin return mechanism of payphones, T-1 repeater powering, HDSL remote unit powering, FTTC powering, etc.
• Used today for powering DAS, DSLAMs, mini-DSLAMs, and FTTH
Typical Line Powering Architecture
Upstream Converter •Converts 48Vdc to +/-190Vdc
•Located in CO (indoor) or remote
power node (outdoor)
Downstream Converter •Converts 200-380Vdc to 48Vdc
•May be integrated into access
equipment’s power supply
•Typically located outdoor
UltraCapacitor •Provides short duration
backup for increased backup
•Parallels onto 48Vdc bus
•Optional accessory
Line Power Reach
Target Application 1: CO Powered DSLAM
• Up converters located in CO
• DSLAM cabinet powered by multiple down converters
• No AC utility or batteries at DSLAM site
• Battery backup provided by reliable CO power plant
Fiber Ethernet
Switch
Up
Converters
Central Office
PSTN
IP
BATT
POTS + xDSL
DSLAM Cabinet
-48Vdc ~ = = =
Down
Converters ±190 Vdc
D
S
L
A
M
~ = = =
Target Application 2: Remote Power Node
• RPN cabinet powered by AC, rectifiers & batteries
• Mini-DSLAM (aka sealed DSLAM) powered by up converters at RPN
• Integrated down converter included in Mini-DSLAM
- or -
• Standalone dual channel 48Vdc down converter for high load Mini-DSLAMs
POTS + xDSL
Remote Power Node Mini-DSLAM
Up Converters
Utility AC
±190 Vdc
+ - Rectifiers
Batteries
+ -
~ =
= =
Fiber
Target Application 3: Fiber to the Home
• Optical Line Terminal (OLT) powered by -48Vdc in CO
• DC-DC up converters in CO provide 190Vdc to Optical Network Terminal (ONT)
• ONT powered by standalone down converter(s)
o 12V for single family unit
o 48V for multiple dwelling unit
±190 VDC
12 or 48 Vdc
Down
Converter
ONT
Central Office
Optical
Line
Terminal
Fiber
BATT Up
Converter
POTS, Data & Video
PSTN
IP
~ = = = = =
Target Application 4: Metropolitan WiFi
• RPN cabinet powered by AC, rectifiers & batteries
• DC-DC up converters in RPN provide 190Vdc to WiFi Access Point
• Access Point powered by standalone down converter(s) providing 12 or 48Vdc
• No need for AC service
±190 VDC
12 or 48 Vdc
Down-Converter
Fiber
WiFi Access Point
= =
Remote Power Node
+ -
Batteries
+ -
~ =
= =
LPS04 4-ch. Sealed
Up-Converter
Utility AC
Rectifiers
= =
12 or 48 Vdc
Local vs Line Powering CapEx Comparison
Fiber Ethernet
Switch
Up
Converters
Central Office
PSTN
IP
BATT
POTS + xDSL
mini-DSLAM Cabinet
-48Vdc ~ = = =
5 x Down
Converters ±190 Vdc
M
i
n
i-
D
S
L
A
M
~ = = =
$1013
10 x 24 AWG Pairs
$1120
Fiber Ethernet
Switch PSTN
IP
BATT
POTS + xDSL
-48Vdc ~ =
M
i
n
i-
D
S
L
A
M
~ =
$0 $1700
AC Service
$1450
BATT
-48Vdc
~ = ~ =
$600
$3750
$2133
Line
Powering
Local
Powering
Line Power Benefits
Avoids proliferation of batteries at the far end of the network
Minimizes the need for accessing AC service
Capitalizes on high reliability, low maintenance
central battery and power system
Uses existing copper cable plant
Reduce time to market & Enables rapid deployment
Reduces CapEx and OpEx
ALPHA Group
INDUSTRIAL POWER SOLUTIONS
ALPHA Group
INDUSTRIAL POWER SOLUTIONS
ALPHA SCR type Charger Series
STANDART Systems SPECTRA I
• Single Phase 6 pulse
• Output Voltage: 24, 48, 130Vdc
• Output Amps: 6, 12, 18, 20, 25, 50
• Made in USA
SPECTRA II
• Single and Three Phase (6 / 12 Pulse)
• Output Voltage: 12V ~ 600V
• Output Amps:Single Phase: 5 ~ 400 ; Three Phase: 25 ~ 1000
• Made in Italy
CUSTOMIZED Systems • Single and Three Phase 6 pulse,
• Output Voltage: 24, 48, 110, 220Vdc
• Output Amps: Single Phase: 10~ 100A ; Three Phase: 30 ~ 600A
• Made in Turkey
ACS:ALPHA Charger Systems
ACS 125/250 HP Series • Single or Three Phases Input
• Output Voltage: 125 and 240Vdc
• Redundant N+1
• Filtering and Communications Package Included
• Hot Swappable
• 1.1kw (natual cooled) OR 4.4kw (forced cooled) SMPS rectifier
modules
• LCD Touch Screen Controller with WEB interface
• Customized solutions for different sizes
• Made in USA, Belgium, Turkey
220VDC/1000A
24VDC/3600A
3 x415VacIN /220VDC bus/1X120VAC OUT Ind.UPS-GE-Gas Turbine Powering
48VDC/24VDC/220VAC Output
Ind.UPS/Oil and Gas
Ind.UPS /Railway