cell
activ
ation Strengthen imm
unity
Better blood �ow preventio
n
Which animal hospitalwould you choose?
Specialized intensive care units designedfor optimum comfort, care and control.
North America Sales and Services www.RcomCo.com
NEWEDITION
UX-U900
IP Camera
7-inch touch screen for ease-of-use and operation
Re�ects veterinarian’s opinions taken at the product concept, leading to optimized design for actual medical situations
Built-in 3 di�erent kinds of lamps not only to brighten inside of the machine(LED Lamp), but to have infrared heat function and to have UVC disinfection system
Smart GUIBased on the needs and requirements of real veterinary professionals IR, Internal light, UVC Lamp
Hand access to enable pet treatment without opening a window
Hand Access
Stainless chamber to enhance durability and sanitation management
Stainless Steel Chamber
Waste tray for easy animal waste removal
Waste Tray
Treatment time settings and alarm functionLED indoor lamp, IR lamp and UVC(Preventing Spread of Viruses) lampQuick button on the home screen for easy control of three kinds of lamp, fan and Timer functionsModular assembly for easy repair and replacement of partsHand access to enable pet treatment without opening the windowBuilt-in outlet to power external devicesStand Pole to easily install various devicesGUI with enhanced stability and con�dence, providing multi language(English, German, Spanish, Portuguese, Russian, Korean, Chinese, Japanese, Arabic)
EASY FUNCTIONS
IP camera function (UX-U900 model) for real-time internal video viewing on mobile and smart phoneBLDC Fan is embedded in the incubator to control indoor-environmentIndependent humidity system, which is easy to use and manageBuilt in Alarm function in case of machine failure(abnormal high temperature, abnormal high concentration of carbon dioxide)
Designed to stack machines on two levels for space e�ciencyDetachable wheels for convenient moving
OTHER FUNCTIONS
Re�ects veterinarian’s opinions taken at the product concept, leading to optimized design for actual medical situationsLarge, touch-screen LCDAutomatic control and settings for Temperature, Humidity, Carbon Dioxide
Control and setting of CO2 concentration (UX-U900 model)Stainless material, easy to sterilize for e�ective sanitation managementAI(Arti�cial Intelligence) electronic controller which can automatically control adjusting cylcle depending on ambient environment of the machineAuto Ventilation function to raise oxygen saturationAuto Ventilation function to lower carbon dioxide concentration
Exterior design and GUI, providing stability and con�dence
MAIN FUNCTIONS
Double insulated structure and ability to distinguish bottom temperature from air temperature, which makes the machine's inside temperature more accurateTransparent tempered glass window to easily check the condition of the pet
Floor Cooling System (UX-U900 model)
Left side Right side Back sideFront side
IDENTIFICATION OF PARTS
VETPEL has become a lifeline in my practice The technology carving out a future
LCD DISPLAY
Setting (Based on UX-U900 model)NEW interface where you can easily control every function
Home (Based on UX-U900 model)7-inch big LCD, for easy and precise control
Nebulizer, oxygen tank can be usedwith our goods (Optional)
INTERIOR
Stand Pole
LCDTouch Screen
Connecting HoleFor Oxygen Tank
Hand AccessWindow
Safety LockSystem
Stainless SteelChamber
Built-inControl Module
HandleIR LampLED Lamp UVC LampOutlet Socker
Upper side maintenance lever – both sides
Handle – both side
Hole to link with oxygen tank
IV stand holder hole (top)
Stand Pole (holder for peripherals) – both sides Internal: chamber, Waste Tray
Internal: IR, internal, and UVC lamps, IPcamera
Power button
Front maintenance lever – both sides
Door locks
LCD touch screen
Hand access window
Exteral outlet (2 outlets)※ Its shape depends on specfcations for each country.
Power panel of humidi�er
Power panel of humidi�er
Leakage circuit breaker
Power input socket
Languagesettings
North America Sales and Services www.RcomCo.com
Model No.
PowerPower Consumption
Controllable temperature rangeTemperature of external environment
Size
AC 100 ~ 120[V] / 220 ~ 240[V] 50/60[Hz]Average. 95[W] Average: 90[W] Average: 85[W]
MAX. 50[℃] MAX. 122[℉] MAX. 50[℃] MAX. 122[℉] MAX. 50[℃] MAX. 122[℉]Optimum range 20 ~ 25[℃] 68 ~ 77[℉]
MAX. 70[%]
-with installation of rotation wheel H 832[mm]
W 692 x L 470 x H494[mm]
VETPEL SPECIFICATION
Controllable humidity rangeMAX. 60[%]
W 916 x L 532 x H 768[mm]
Internal
External
Humidity of external environment
MAX. 4000[ppm] MAX. 4000[ppm] XControllable carbon dioxide rangeMAX. 40[%] X XControllable oxygen concentration range
UX-U900 PX-U900 MX-U900Display LCD (Touch Screen) LCD (Touch Screen) FND
VETPEL & PET Brooder(MX-BL600N model)
ImageVETPEL Stack-up Image
※ For safety reasons, we recommend a maximum stacking height of 2x VETPEL units.
VETPEL o�ers the best in luxury and practicalityfor your business.
Basicsfeci�cation
*Option:Nebulizer
FND Display
Automatic temp. setting Function
Automatic Humi. setting Function
LED Lamp
Tray
Air ventilation + Humidi�cation fan
Air �lter
Anion function [odor remove]
Water pump
Micro processor controller
PTC Heater
View window
Consists of several functions suitable for both home and veterinary treatment of petsYou can set the optimal recovery environment according to pet's health condition.
Rcom Pet Brooder&ICU
MX-BS600N / MX-BL600N
Pet Brooder & ICU have two di�erent sizes.
57[kg] (N.W.) 63[kg] (G.W) 56[kg] (N.W.) 62[kg] (G.W) 55[kg] (N.W.) 61[kg] (G.W)Wheigt
North America Sales and Services www.RcomCo.com
RCOM VETPEL. ICU ModelAvailable for optimal environment settings depending on pet’s condition
Display
Function / Model No.
Air temperature indicator
Floor Cooling System (Range: MAX. 50℃)
IP Camera
Multi-language display and controls(English, German, Spanish, Portuguese, Russian, Korean, Chinese, Japanese, Arabic)
IR Lamp
UVC Lamp
IV stand holder hole
LED Lamp
Ventilation device
Waste Tray
Stand Pole to easily install various devices
Stand Pole to easily install various devices
Hand access window
Exteral outlet (2 outlets)
Air �lter
Leakage circuit breaker
Fixed rubber feet
Alarm for high concentration of carbon dioxide
Carbon dioxide indicator and automatic carbon dioxide emission(Range: MAX. 4000ppm)
Automatic humidity emission
Control Fan speed (Range: 40~100%)
Humidity system (Display Range: MAX. 70%)
Treatment time settings and alarm function (Range: 0~24Hour, 1minute unit)
LCD (Touch)
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Automatic
O
O
O
O
O
O
O
O
PRO+(UX-U900)
LCD (Touch)
O
X
X
O
O
O
O
O
O
O
O
O
O
O
Automatic
O
O
O
O
O
O
O
O
PRO(PX-U900)
FND
XFloor temperature indicator and 3 ways of heating(PRO+ Range: MAX. 50℃ / PRO, MAX Range: MAX. 50℃) O O O
X
X
Oxygen concentration indicator (Range: MAX. 40%) O X X
X
O
O
X
X
X
Alarm for abnormal high temperature O O X
X
X
X
O
Osemi-
automatic
O
O
O
O
O
O
O
O
Rotary wheel O O Option
MAX(MX-U900)