ELLIPTICAL MOBILE SOLUTIONS Advantages of Micro-Modular Data Centers
Transcript
Page 1: Whitesands

ELLIPTICAL MOBILE SOLUTIONS

Advantages of Micro-Modular Data Centers

Page 2: Whitesands

Elliptical Mobile Solutions

2Copyright Elliptical Mobile Solutions 2010 www.ellipticalmobilesolutions.com

“The Next Generation of Modular Data Centers”

C3-S.P.E.A.R.

R.A.S.E.R.

S.P.E.A.R.

Page 3: Whitesands

EMS Value Proposition

Copyright Elliptical Mobile Solutions 2010 www.ellipticalmobilesolutions.com 3

• Capital Costs reduced 50 – 80%

• Operating Costs reduced 40 – 65% • Modular Distributed Computing Platform

that is Vendor Neutral

• Turnkey Solutions

Page 4: Whitesands

The Illustration Behind The EMS Value Proposition

4Copyright Elliptical Mobile Solutions 2010 www.ellipticalmobilesolutions.com

=

Page 5: Whitesands

EMS Products are “The Facilities” for your IT Equipment

5Copyright Elliptical Mobile Solutions 2010 www.ellipticalmobilesolutions.com

EMS Provides:•Cooling•Security•Fire Suppression•Mobile Platform

You Provide:•Electricity•Connection to your network•Any Equipment

Page 6: Whitesands

EMS Product Line ofMicro-Modular Data Centers (MMDCs)

S.P.E.A.R. : 22U Armored, Mobile , Power

Assisted Enclosure

R.A.S.E.R. : 42U Re-locatable

Enclosure

C³-S.P.E.A.R.: 24U Mobile, Power

Assisted Enclosure

6Copyright Elliptical Mobile Solutions 2010, www.ellipticalmobilesolutions.com,

Small, scalable to provide an affordable data center, disaster recovery or co-location alternative.

Full height, 42U enclosure designed specifically for new data center builds or data center expansions.

Designed for agile, high-density computing applications where mobility, shielding, environmental protection, and disaster tolerance are priorities.

Page 7: Whitesands

Industry Direction Change

Modular/Containerized Data Centers • Benefits over Traditional Data Centers

Include:– CAPEX savings of 35-50%

– OPEX savings of 20-30%

– Time to Deploy from years to 6-8 months

Micro-Modular Data Centers• Benefits over Modular Data Centers

Include:– CAPEX additional savings of 40-50% – OPEX additional savings of 30-35%– Significant Flexibility– Time to Deploy to 2 months

Copyright Elliptical Mobile Solutions 2010 www.ellipticalmobilesolutions.com

There is a paradigm shift occurring in today’s Data Center market. By definition, this is a change from one way of thinking to another. It's a revolution, a transformation, a sort of metamorphosis. It just does not happen, but rather it is driven by agents of change.

Why are companies like IBM, Microsoft, Sun, HP and Google all entering the Modular/Containerized Data Center Market?

Page 8: Whitesands

C³-S.P.E.A.R.Product Features

• A Climate Controlled Campus-Self-Propelled, Electronic, Adaptable Rack designed to protect equipment from environments and situations that would render standard rack mounted equipment inoperable.

• C³-S.P.E.A.R. can be used to protect any combination of rack mounted electronic equipment. The C³-S.P.E.A.R. can deploy its stable and secure operating environment virtually anywhere.

• The power assist makes for the first time 1,000 lbs of

sensitive equipment and cooling systems easily portable by one person.Optional Upgrade Features:

3/8” square or 10-32 tapped rail Programmable electronic locks with multi-tier security and audit trailWater Heat ExchangerExternal RF AntennasPass-through Patch PanelNEMA12 Environmental PackageFireTrace® active fire suppression with Novek® 1230

Technical Specifications:

Dimensions……..………60” tall x 24” wide x 66” long* Weight…………………………………............. 400 lbs*Capacity………………………………...... 1,000 lbs*Mobility Range……………………………… 10 miles*Speed……………………...................................2.6 mphOperational temperature …………………. 0˚ to 120˚F*Internal Storage Capacity……………………….. 24 UTotal Cooling Capacity…………..2.5 KW Single A/C 6.0 KW Dual A/C* depending upon upgrade options selected

Page 9: Whitesands

Patented Forced Air Convection Equipment Cooling

Inside air and outside air never mix

All of our products allow you to establish a computing environment or data center anywhere. All that is needed is power and connectivity. Cooling, fire protection, EMI shielding, security, raised floor, hot and cold aisle, are all self contained in each enclosure

Page 10: Whitesands

Portable Enterprise Class Wireless Client Support for Remote Office Applications

Simplify and Secure Infrastructure Support for IT Equipment

Page 11: Whitesands

R.A.S.E.R. - PERFECTLY SCALABLE

11

•Micro Modular Design

•42U Sealed Enclosure

•Vendor Neutral 19” Form Factor

•42,000 BTU HVAC

•Closed Loop Cooled

•Hot & Cold Aisle Containment

•Pre-engineered High Density

•Rack Level CyberLock Security

•Active Fire Suppression

•Mobility

•Easy Serviceability

Copyright Elliptical Mobile Solutions 2010 www.ellipticalmobilesolutions.com

DATA CENTER “IN A BOX”

Page 12: Whitesands

New Data Center AlternativesHybrid (Shared Space) High Density Zone that needs no infrastructure

Shared Space Example

•4 RASER Units•224 Blade Servers•1794 Cores•960TB Storage•PUE 1.5-1.1•48-64KW IT Load

Page 13: Whitesands

Equipment

Equipment

Equipment

Equipment

High powered fan will continue to move air

during datacenter power outage

Cool Ambient Air

Hot air from equipment

Copyright Elliptical Mobile Solutions 2009 1

Mission Critical Venting

Close up view

Inside View

Page 14: Whitesands

• Firetrace Systems provide Cost-Effective, Stand-Alone, Automatic Fire Suppression Systems for your Critical Equipment, Electrical/Technical Systems and various types of enclosures.

• Novaec 1230 is a dielectric substance which is harmless to electronic equipment even during operation.

• Novaec 1230 is a totally “clean” (non toxic) agent which eliminates permitting issues and eliminates clean up.

• A Firetrace System can be utilized anywhere that a fire poses a risk,  and it is flexible enough for virtually any Industrial Equipment.

Active Fire Suppression System

3M™ Novec™ 1230 Fluid

150,000 units installed worldwide

Page 15: Whitesands

Fire Proofing Insulation

• Aerogel Insulation provides thermal protection from external or internal sources

• Air Tight RASER does not support combustion.

Fires in the data center typically initiate through electrical equipment or component failure…”-Lance Harry, business development manager for Fenwal Protection Systems

Self contained modules compartmentalize damage to overall Data Center environment.

Page 16: Whitesands

• Fully Customizable Encrypted Security Access– Limitation by time or day (9am –

5pm)– Limitation by personnel (Network

Equipment Only or Servers Only)

– Monthly Expiration and Renewal

• 4,000 user event auditable trail – Track who opens what and when.

• Field Programmable

CyberLock Multi-tier Security System

Integrated electronic security

4 levels of security access to the enclosure. The patch panel, both equipment doors, and propulsion system are all secured with unique keys

Copyright Elliptical Mobile Solutions 2010 www.ellipticalmobilesolutions.com

Page 17: Whitesands

Enclosed RASER ROOM or “Pod”

Dedicated “make up” air supply or high volume adiabatic

cooling for redundancy

RASER is free standing Room

isolated so it can be “pumped” effectively

Page 18: Whitesands

Permanent

Page 19: Whitesands

Mobile and Semi Permanent

Page 20: Whitesands

Copyright Elliptical Mobile Solutions 2010 www.ellipticalmobilesolutions.com

Why EMS?

• Save Money– Eliminate costly infrastructure with a self-contained, high-density, cost-effective and energy

efficient data center.

– Reduce the costs to plan, build and implement your data center

– Reduce overall operating expenses

• Save Energy– Patented closed loop cooling dramatically cuts cooling and electrical costs

– Significantly reduce data center’s harmful carbon footprint

• Save Time– Micro-Modular Data Centers can be built, fully populated and delivered in weeks vs. months

or years

– Have a fully functional data center when, where and for however long you need it

• Save Space– Reduce your data center footprint by up to 70 percent

– EMS products can be located in a warehouse, garage, office or closet

Page 21: Whitesands

11”

80”

Cabinet 43”

30”

82”

Side View Front View

26”

Page 22: Whitesands

EXAMPLE 2U Network

patch Panel

Power/Data can enter the top/bottom of sidecar or

through existing raised floor

Lockable/ Cyberlock Access Door•Protects patch area•Reports access

Mix or match 4 Power/Data Entry Grommet Gland

Locations

EXAMPLE2U Media Converter

Optional 4” Fan

Mounts

R.A.S.E.R. “Sidecar”

Power/Data can enter the top/bottom or through

existing raised floor

Power/Data Entry Knockouts/Grommets

Vertically mount 3 “2U” piece of

low density network, VIOP,etc

Page 23: Whitesands

23

EXAMPLE SOLUTION

23Copyright Elliptical Mobile Solutions 2010 www.ellipticalmobilesolutions.com

Page 24: Whitesands

Expand Data Center Capacity with Energy Efficient High Density Zone

TOTAL: 300 TB OF STORAGE

“EXAMPLE SOLUTION”

“Future Growth” 160 TB

CISCO UCS Blade Servers

NETAPP STORAGE

Page 25: Whitesands

42U Hardened, Portable and Energy Efficient Container

Page 26: Whitesands

RASER’s offer a NEW LEVEL of RELIABILITY

Connect the COOLING AND IT load in the RASER to the UPS!•Simplifies Electrical Cabling•Increases Reliability

Traditional Way

Utility Power UPS ITTransfer Switch

CRACGenerator

Delay to start

EMS Way

Utility Power UPS Cooling AND ITGenerator

•Complex wiring•Generator may not start•Generator delay causes room temperature to rise•Delay for Chiller/CRAC to restart can cause room temp to rise

•Simplified wiring•Generator has time•No Delay•No Interruption

Transfer Switch

Page 27: Whitesands

High Density Zone

Page 28: Whitesands

RETRO FIT your Data Center without disrupting your current environment.

Page 29: Whitesands

- Convert any location into A high density Zone

- Streamline Project Management

- Reduce Installation & Design Costs

- Project finished in 10 weeks or less

“EXAMPLE SOLUTION”

“Future Growth” 160 TB

54KW TOTAL POWER DRAW AT CAPACITY IT = 36 KW A/C = 18 KW

12KW IT6 KW A/C

12KW IT6 KW A/C

12KW IT6 KW A/C

*PUE 1.5

*PUE - power usage effectiveness