+ All Categories
Home > Documents > Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing...

Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing...

Date post: 27-Mar-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
64
Whole-body Vibration Exposure: What you need to know to prevent vibration induced injuries Tammy Eger, PhD Associate Professor, School of Human Kinetics Director, Centre for Research in Occupational Safety and Health Laurentian University Alison Godwin, PhD Assistant Professor, School of Human Kinetics Centre for Research in Occupational Safety and Health Laurentian University Workplace Safety North Health of a Miner November 12, 2014
Transcript
Page 1: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Whole-body Vibration Exposure: What you need to know to prevent vibration induced injuries Tammy Eger, PhD Associate Professor, School of Human Kinetics Director, Centre for Research in Occupational Safety and Health Laurentian University Alison Godwin, PhD Assistant Professor, School of Human Kinetics Centre for Research in Occupational Safety and Health Laurentian University

Workplace Safety North Health of a Miner

November 12, 2014

Page 2: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

• Vibration basics

• Occupational exposed to vibration

– Whole-body vibration

– Foot-transmitted vibration

• Health risks

• Evaluation methods

• Prevention/reduction strategies

Presentation Overview

Page 3: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Vibration “Types”

• Whole-body vibration (WBV)

• Hand-arm vibration (HAV)

• Foot-transmitted vibration (FTV)

FTV

HAV

WBV FTV

HAV

Page 4: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Vibration Basics

4 factors are required to describe human response to vibration:

• Magnitude

– ‘bounce height’ (m/s2)

• Frequency

– # of ‘bounces’ per sec. (Hz)

• Direction

– X, Y , Z axes

• Duration

– length of exposure time

DF z-axis 4.0 Hz

Page 5: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Vibration Basics

4 factors are required to describe human response to vibration:

• Magnitude

– ‘bounce height’ (m/s2)

• Frequency

– # of ‘bounces’ per sec. (Hz)

• Direction

– X, Y , Z axes

• Duration

– length of exposure time

From: http://www.ilo.org/safework_bookshelf/english?content&nd=857170580

Page 6: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Exposure at resonance is linked with increase injury risk

Image From: http://physics.stackexchange.com/questions/

Page 7: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Health Risks: Whole-body Vibration

• lower-back pain, spinal degeneration, neck problems

• muscle fatigue

• sleep problems, headaches, & nausea

• hearing loss

• gastro-intestinal tract problems

(Scutter et al., 1997; Seidel, 1993; Seidel, 2005; Thalheimer, 1996; Mansfield, 2005)

Page 8: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Health Risks: Foot-Transmitted Vibration

- Pain and numbness in the toes and feet

- Increased sensitivity to cold

- Blanching of toes

- Joint pain

Vibration-Induced White-Foot

(Thompson et al., 2010)

Page 9: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Hand-Arm Vibration Syndrome

• Vascular component of HAVS – Blanching of the fingers

– Trophic changes to the skin

Page 10: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Evaluation Methods

Page 11: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Predicting Health Risks

Vibration Type Standard

Whole-Body Vibration ISO 2631-1

ISO 2631-5

EU Directive 2002/44/EC

Hand-Arm Vibration ISO 5349-1

EU Directive 2002/44/EC

Foot Transmitted Vibration

???

Page 12: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

WBV is measured in accordance with ISO 2631-1

Tri-axial

accelerometer

mounted in rubber

seat pad

Seat pad positioned on

vehicle seat

Data-logger used to record

the vibration data collected

in the field

Measuring WBV

Page 13: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

WBV v1.0, ByteWorks

http://ergonomics.uq.edu.au/WBV/WBVpod/Index.html

Page 14: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

ISO 2631-1

Page 15: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

ISO 2631-1 HGCZ

To predict health risk for DAILY exposure 8hr

equivalent values are calculated

Page 16: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Health Risk

Determination

HIGH

MODERATE

LOW

Page 17: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

“Probable”

Health

Risk

ISO 2631-1 EU Directive

A(8) VDVtotal A(8) VDVtotal

(m/s2 ) (m/s1.75) (m/s2 ) (m/s1.75)

low < 0.45 < 8.5 < 0.5 < 9.1

moderate 0.45 - 0.90 8.5 - 17 0.5 – 1.15 9.1 – 21

high > 0.9 > 17 > 1.15 > 21

“Guidelines” WBV Exposure

Page 18: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Example: WBV Field Study: Load-Haul-Dump Vehicle

Health risk predictions based on ISO 2631-1 HGCZ comparison

0

0.25

0.5

0.75

1

1.25

1.5

1.75

2

2.25

A(8

) m

/s2

Large LHD Vehicles Small LHD Vehicles

Within

HGCZ

Below

HGCZ

Above

HGCZ

4 of 11 (large)

LHD operators were exposed the WBV levels above the HGCZ

7 of 10 (small)

LHD operators were exposed the WBV levels above the HGCZ

Page 19: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

WBV Exposure Mining Equipment Operation

Page 20: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

WBV Exposure Mining Equipment Operation

Page 21: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

From: EU Good Practice Guide to WBV

Haultruck 1.2m/s2

Bulldozer 1.64 m/s2

LHD 2.25 m/s2

Page 22: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Measuring FTV

• No specific standard

– ISO 2631-1

– ISO 5349-1

Portable Datalogger

Attached to Floor of Underground Mining Equipment

Non-metal Seat Pad

Metal Magnet

Tri-axial Accelerometers (NexGen Ergonomics, Montreal, QC, CND)

Page 23: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Foot-transmitted Vibration

• In a recent field study by Leduc et al., 2010, FTV characteristics were reported:

Machine

awz

(m/s2) DFz (Hz)

Locomotive-1 0.43 6.3

Locomotive-2 0.36 3.15

Jumbo-1 Boom 0.44 31.5

Wooden Raise 1.13 40

Metal Raise 1.08 40

Dominant Frequency btw 3.15 – 6.3 Hz

Dominant Frequency btw 31-5-40 Hz

According to ISO 2631-1 Raise workers were above the 8hr HCGZ

Page 24: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Foot-Transmitted Vibration

Raise Platform Workers

• 100 % hand problems

• 75 % had foot problems

• Raise workers were exposed to the greatest magnitude of FTV

• Dominant exposure frequency was 40 Hz

2 of 3 raise workers were diagnosed by their doctor to have VWFt and HAVS

Page 25: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Mining and FTV

• 6/27 miners displayed Raynaud’s phenomenon in their feet after having stood on platforms with attached drills (Hedlund, 1989)

• Case study report – a miner (bolter) with vibration induced white foot without corresponding HAV syndrome (Thompson et al., 2010)

Page 26: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

FTV Exposure Mining Equipment Operation

Page 27: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Toe Waveforms at Room Temperature Right Foot Left Foot

Toe Waveforms Post-cold Stress Right Foot Left Foot

Finger Waveforms Post-cold Stress Right Hand Left Hand

Finger Waveforms at Room Temperature Right Hand Left Hand

Page 28: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Interventions and Prevention Strategies

Page 29: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Hierarchy of Controls

Personal Protective Equipment

Administration

Engineering

Substitution

Elimination

Page 30: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Factors Influencing WBV Exposure

Risk potential (ISO 2631-1)

Exposure duration Vibration characteristics

Road condition Maintenance

Suspension Seat design

Vehicle load

Tire pressure

Driving style

Shift length

Page 31: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Driving Speed

G1 G2 G3 AS

Terrain Rough

Maintained

Haulage Loaded

Unloaded

Driving Task

Forward Backward Mucking

Ride Control

On Off

7.2 m3 bucket capacity 5.7 m3 bucket capacity

Frequency-Weighted RMS Vibration (floor/seat interface)

(operator/seat interface)

ISO 2631-1 HGCZ A(8)

VDVtotal

EU Directive A(8)

VDVtotal

X X X X

Page 32: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Ride Control

WBV exposure was lower with Ride Control engaged

5.7 m3 Bucket LHD

Page 33: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Decrease Speed

Decreased WBV exposure with reduced speed - avoid 4th gear

5.7 m3 Bucket LHD

Page 34: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Maintain Roadways

Decreased WBV exposure with maintained roadways

5.7 m3 Bucket LHD

Page 35: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Seat “performance” matters

Decreased WBV exposure with a seat SUITED to the equipment Exposure was still within ISO HGCZ BUT below EU 2002/44/EC action value

5.7 m3 Bucket LHD

Page 36: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Field Test Evaluation of a NEW “Ergonomic” Seat

BLUE = seat RED=floor

Page 37: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

S.E.A.T. (seat effective amplitude transmissibility)

Vibration measured at the seat

_________________ Vibration measured

at the floor

A rigid seat = ratio of 1.0 A value greater than 1 = amplification A value less than 1 = attenuation

Page 38: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Seat Performance

FIELD TESTING:

Evidence was found to indicate seats in LHD vehicles were AMPLIFYING the vibration

Laboratory Study Seat Evaluation

Frequency Response H1(Coussin,Base) - Mark 1 (Magnitude)

Working : Set85kg(75%course)_LoadPDrouin(85kg)_Pot50_Capacitif : Input : FFT Analyzer

1 2 3 4 5 6 7 8 9 10

0

200m

400m

600m

800m

1

1,2

1,4

1,6

1,8

2

[Hz]

[(m/s²)/(m/s²)] Frequency Response H1(Coussin,Base) - Mark 1 (Magnitude)

Working : Set85kg(75%course)_LoadPDrouin(85kg)_Pot50_Capacitif : Input : FFT Analyzer

1 2 3 4 5 6 7 8 9 10

0

200m

400m

600m

800m

1

1,2

1,4

1,6

1,8

2

[Hz]

[(m/s²)/(m/s²)]

LAB testing CONFIRMED the seat amplified

the vibration (in the DF range)

Page 39: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Seating Innovations

• New seating was intended to – Improve seating posture

• Allow greater adjustability

– Improve seating comfort • Avoid end-stops due to

vibration impacts

– Attenuate vibration • Decrease WBV exposure

NEW does not always mean BETTER

Page 40: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Seat Selection is Important

• Paddan and Griffin (2002) evaluated the vibration isolation efficiency for 100 seats found in 14 different types of vehicles and found 94 % of the vehicles evaluated would have improved vibration attenuation if a seat from one of the other vehicles tested in the study was used over the current seat.

Page 41: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

30 of the most common field vibration profiles were used to evaluate the seats

Seat Testing

(Dickey et al., 2013)

Page 42: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Access new, ½ worn, fully worn out

KAB 525 new, ½ worn, fully worn out

KAB 301 new, CAT new, ISRI worn out

Seat Evaluations

Page 43: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

(Dickey et al., 2013)

Page 44: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

What does this mean? Based on the vibration profiles (created from UG mining equipment operation) the CAT seat generally performed better.

(Dickey et al., 2013)

Page 45: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Don’t Forget Posture

Posture Matters

Increased low-back injury risk when WBV exposure is combined with non-neutral working postures

Port workers – cranes & lift trucks (Bovenzi et al., 2002)

Farm workers – tractors (Wikstrom, 1993; Bovenzi & Betta, 1994)

Construction – excavators, pavers etc. (Kittusamy and Buchholz, 2004)

Locomotive operators (Johanning et al., 2002 ) LHD operators (Eger et al., 2009)

Page 46: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

WBV Interventions

• Remove the worker from vibration source

• Purchase equipment with lower vibration emissions

• Maintain equipment (and roadways)

• Reduce driving speed

• Install suspension and seating suited to the conditions

• Maintain a neutral driving posture

Page 47: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Interventions HAV and FTV

Page 48: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Procedures to Reduce Vibration Exposure of Tools

• Purchase lower vibration tools – Purchasing policy for company

• Tool maintenance – Set up maintenance and replacement program for vibrating

tools – Keep cutting tools sharp

– Replace worn parts

– Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling, hardening)

– Checking/replacing defective vibration dampers, bearings, gears

Page 49: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Better Equipment Drill with an “anti-vibration” intervention

LOCOMOTIVE1

LOCOMOTIVE2

JUMBO DRILL

WOODEN RAISE

METAL RAISE

METAL RAISE "ANTI-VIBRATION" DRILL

BOLTER

0

0.2

0.4

0.6

0.8

1

1.2

A(8

) V

alu

e (m

/s2)

EQUIPMENT TYPE

HEALTH GUIDANCE CAUTION ZONE

PRIMARY

SECONDARY

Below 0.45 m/s2 – Health effects are unlikely 0.45-0.9 m/s2 – Health Guidance Caution Zone: Health effects are possible Above 0.9 m/s2 – Health effects are likely

Page 50: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Better Equipment Jumbo with a isolation platform

LOCOMOTIVE1

LOCOMOTIVE2

JUMBO DRILL

WOODEN RAISE

METAL RAISE

METAL RAISE "ANTI-VIBRATION" DRILL

BOLTER

0

0.2

0.4

0.6

0.8

1

1.2

A(8

) V

alu

e (m

/s2)

EQUIPMENT TYPE

HEALTH GUIDANCE CAUTION ZONE

PRIMARY

SECONDARY

Page 51: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Administrative Controls

• Minimizing exposure time – Job rotation/Scheduling

• If working in cold ambient conditions, provide opportunity for re-warming – Warm building/shelter for breaks

– Portable hand warmers

Page 52: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Personal Protective Equipment

Anti-vibration gloves

• ISO/ANSI certified – Full fingered

– Meet the vibration dampening requirements (ISO) • 31.5-200 Hz: Transmission < 1.0

• >200 -1000Hz: Transmission < 0.6

PPE for FTV

Matts

Boots

Insoles

Page 53: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Vibration Induced Injury

Whole-Body Vibration (WBV)

Hand-Arm Vibration Syndrome (HAVs)

Vibration Induced White Foot

• spine disorders

• neck disorders

• gastrointestinal

disorders

• osteoarticular, neurological and vascular disorders including vibration induced white finger and vibration induced white feet

Page 54: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

OHS Legislation

No occupational health and safety regulations specifically related to vibration in Ontario

–General Duty Clause

• 25.(2)(h) every reasonable precaution.. “take every precaution reasonable in the circumstances for the protection of a worker.” (OHSA)

Page 55: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Vibration Workshop December 2nd

Page 56: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Helpful Resources

Page 57: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Other Information on Vibration

http://www.hse.gov.uk/vibration/index.htm

Page 58: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Industry Partners Workplace Safety North Ontario Mining Industry Mining Equipment Manufacturers

Research Partners Dr. Paul-Emile Boileau, IRSST (Montreal, QC) Dr. James Dickey, University of Western Ontario Dr. Ron House, St. Michael’s Hospital Dr. Michele Oliver, University of Guelph Dr. Aaron Thompson, St. Micheal’s Hospital

Acknowledgements

Funding Agencies

Page 59: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

For more information contact: Tammy Eger, Ph.D.

Associate Professor, School of Human Kinetics

Director, Centre for Research in Occupational Safety and Health

Laurentian University

Ramsey Lake Road, Sudbury, ON, Canada, P3E 2C6

Tel: 705-675-1151 ext. 1005

E-mail: [email protected]

Web: www.crosh.ca

Twitter: @crosh_crsst

CROSH Centre for Research in Occupational Safety and Health

Page 60: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Standards

• International Organization for Standardization. ISO-5349 Mechanical Vibration Measurement and Evaluation of Human. Exposure to Hand-transmitted Vibration Part 1: General Requirements. 2001.Geneva, Switzerland.

• International Organization for Standardization, 1997. ISO 2631-1 Mechanical Vibration and Shock—Evaluation of Human Exposure to Whole-Body Vibration—Part 1: General Requirements, Geneva, Switzerland. Reference number ISO 2631-1:1997(E).

• International Organization for Standardization (ISO): Mechanical vibration and shock – Evaluation of human exposure to whole-body vibration – Part 5: Method for evaluation of vibration containing multiple shocks (ISO 2631-5). [Standard] Geneva, Switzerland: ISO, 2004.

• Directive 2002/44/EC of the European parliament and of the Council of 25 June 2002 on the minimum health and safety requirements regarding the exposure of workers to the risks arising from physical agents (vibration) (sixteenth individual Directive within the meaning of Article 16(1) of Directive 89/391/EEC)

Page 61: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

• Bovenzi, M., Health effects of mechanical vibration, G Ital Med Lav Erg, 2005, 27(1), 58-64. • Bovenzi, M., Betta, A., 1994. Low-back disorders in agricultural tractor drivers exposed to whole-body vibration and postural stress. Applied

Ergonomics 25 (4), 231–241. • Bovenzi, M., Pinto, I., Stacchini, N., 2002. Low back pain in port machinery operators. Journal of Sound and Vibration 253 (1), 3–20. • Cann, A., Vi, P., Salmoni, A. and Eger, T. An exploratory study of whole-body vibration exposure and dose while operating heavy equipment in the

construction industry. Applied Occupational Environmental Hygiene, 2003, 18(12), 1999-2005. • Cann, A., Salmoni, A. and Eger, T. Predictors of whole-body vibration exposure in transport truck operators. Ergonomics, 2004, 47(13), 1432-1453. • Dong, R.G., Schopper, A.W., McDowell, T.W., Welcome, D.E., Wu, J.Z., Smutz, W.P., Warren, C. and Rakheja, S., Vibration energy absorption (VEA) in

human fingers-hand-arm system, Medical Engineering & Physics, 2004, 26(6), 483-492. • Edwards, D., and Holt, G. 2010. Analysis of hand-arm vibration risk to highway maintenance and repair operatives. Automation in Construction.

19:580-587 • Eger, T., Stevenson, J., Boileau, P. E., Salmoni, A., & VibRG. Predictions of health risks associated with the operation of load-haul-dump mining

vehicles: Part 1—Analysis of whole-body vibration exposure using ISO 2631-1 and ISO-2631-5 standards. International Journal of Industrial Ergonomics, 2008, 38, 726-738.

• Eger, T., Contratto, M., and J.P. Dickey (2011) Influence of Driving Speed, Terrain, Seat Performance and Ride Control on Predicted Health Risk Based on ISO 2631-1 and EU Directive 2002/44/EC. Journal of Low Frequency Noise Vibration and Active Control. Vol.30(4) 291-312

• Hagberg M (2002). Clinical assessment of musculoskeletal disorders in workers exposed to hand-arm vibration. Int Arch Occup Environ Health. 75:97-105

• Johanning, E., Fischer, S., Christ, E., Gores, B., Landsbergis, P., 2002. Whole-body vibration exposure study in US railroad locomotives—an ergonomic risk assessment. American Industrial Hygiene Association Journal 63, 439–446.

• Kittusamy, N., Buchholz, B., 2004. Whole body vibration and postural stress among operators of construction equipment: a literature review. Journal of Safety Research 35, 255–261.

• Leduc, M., Eger, T., Godwin, A., Dickey, J.P., and House, R. (2011) Examination of vibration characteristics and reported musculoskeletal discomfort in workers exposed to vibration via the feet. Journal of Low Frequency Noise, Vibration and Active Control. Vol 30(3); 197-206.

• Pelmear PL. The clinical assessment of hand-arm vibration syndrome. Occup Med (Lond) 2003;53:337–341. • Scutter, S., Turker, K., Hall, R., 1997. Headaches and neck pain in farmers. Australian Journal of Rural Health 5 (1), 2–5. • Schweigert, M., The relationship between hand-arm vibration and lower extremity clinical manifestations: a review of the literature, International

Archives of Occupational and Environmental Health, 2002, 75, 179-185. • Seidel, H. Selected health risks caused by long-term whole-body vibration. American Journal of Industrial Medicine, 1993, 23(4), 589-604. • Seidel, H. On the relationship between whole-body vibration exposure and spinal health risk. Industrial Health, 2005, 43, 361-377. • Thalheimer, E., Practical approach to measurement and evaluation of exposure to whole-body vibration in the workplace, Seminars in Perinatology,

1996, 20(1), 77-89. • Thompson, A.M.S., House, R., Krajnak, K. and Eger, T., Vibration-white foot: a case report, Occupational Medicine, 2010, 60, 572-574. • Wikstrom, B., 1993. Effects from twisted postures and whole-body vibration during driving. International Journal of Industrial Ergonomics 12, 61–75

References

Page 62: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

Quantifies risk to the lumbar spine

Page 63: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,

ISO 2631-1 & ISO 2631-5 Predicted Health Risk Variables

“Health Risk”

ISO 2631-1 ISO 2631-5

A(8) VDVtotal Sed R Factor

(m/s2 ) (m/s1.75) (MPa)

low < 0.45 < 8.5 < 0.5 < 0.8

moderate 0.45 - 0.90 8.5 - 17 0.5 - 0.8 0.8 - 1.2

high > 0.9 > 17 > 0.8 > 1.2

Page 64: Whole-body Vibration Exposure · –Keep cutting tools sharp –Replace worn parts –Replacing anti-vibration mounts & suspended handles before they deteriorate (cracking, swelling,