PROJECT Hillsborough County Sheriff’s Office Firing Range and Workout Gym Pinebrooke Business Park PROJECT NUMBER 1626/ 05-07 ADDENUM NO. One (01) ADDENUM DATE 02/15/17 The following items hereby become a part of the Contract Documents for the above referenced project. IN SPECIFICATIONS
1. Specification Section: 04 2000 - CONCRETE UNIT MASONRY
A. Add Paragraph 2.2, B, 3, a. as follows: “Split face units shall match the existing building texture and color. Provide samples for selection to Architect prior to order.”
2. Specification Section: 08 5659 – SERVICE WINDOW UNITS
B. Add the specification section in its entirty dated 2/15/2107 to the Project Manaual.
3. Specification Section: 31 3116 - TERMITE CONTROL
A. Add the specification section in its entirty dated 2/15/2107 to the Project Manaual. ON THE DRAWINGS
4. Sheet No. A1.2 – FLOOR PLAN FIRING RANGE
A. Revise location of mop sink and water heater in Janitor’s Closet #610.
B. Revise the Mechaincal Yard dimensions and construction.
C. Revise Plan to locate the air compressor.
D. Partition Type P-14 added to Plan.
E. Provide pocket in Training Room APC for overhead door clearance.
F. Revise Plan to indicate signage locations.
5. Sheet No. A1.3 – FLOOR PLAN FIRING RANGE
A. Storage Room 708 and Electrical Room 709 locations have been revised.
B. Revise Specific Notes to include the following “ 7. PROVIDE WOOD BLOCKING @ 9'-0" AFF FOR OWNER PROVIDED AND INSTALLED FAN.”
C. Revise Plan to include locations for fan blocking.
D. Provide pocket in Boxing Training Room APC for overhead door clearance.
E. Provide double door between Weight Room and Boxing Training Room.
F. Revise Plan to indicate signage locations.
WILDERARCHITECTURE, INC. ADDENDUM ONE (01)
1315 East Seventh Avenue | Suite 106 Tampa, Florida 33605
(813) 242-6677 wilderarchitecture.com
AA26000655
6. Sheet No. A1.4 – DEMOLITION PLAN
A. Add Sheet A1.4, dated 2/15/17 to the Drawings.
7. Sheet No. A2.1 – ENLARGED TOILET ROOM PLANS AND ELEVATIONS
A. Detail F1 – Clarify Note #7.
B. Detail H1 – Clarify Note #7.
C. Relocate Mop Sink and mop holder.
8. Sheet No. A4.1 – BUILDING SECTION
A. Modify mechanical Yard Enclosure.
9. Sheet No. A4.3 – PARTITION TYPES
A. Revise sheet to include Partition Type P14.
10. Sheet No. A7.1 – FINISH SCHEDULE AND DOOR TYPES
A. Revise Finish Schedule Abbreviations to include CPT – Carpet Tile
B. Revise Door Schedule Remarks to include Notes 10 & 11.
C. Revise information for the following doors: 600A, 608, 700A, 700B, 700C & 707C.
D. Add door 600 at Mechanical Yard.
E. Revise sheet to include Door Types D05 & D06.
F. Revise glazing type for window W07.
G. Revise material type for window W07.
H. Revise sheet to include door types D05 & D06.
11. Sheet No. A8.1 – CASEWORK ELEVATIONS
A. Revise Casework C04, Detail J1/A8.1
12. Sheet No. A8.2 – CASEWORK SECTIONS
A. Detail H1 – Revise Casework Height.
B. Detail H4 – Revise Detail Number.
C. Revise Sheet to include Detail H11.
13. Sheet No. S2.1 – SECTIONS & DETAILS FIRING RANGE
14. Revise Mechanical enclosure as shown in the revised sheet.
15. Sheet No. S3.2 – SECTIONS & DETAILS FIRING RANGE
A. Refer to details 2 and 4. Where used to describe the construction at Room 605 Armory the top of bond beam shall be 12’-0”. Reduce heigh of wall, knock out courses, and vertical reinforcement to correspond with the reduced height of the CMU walls of this room.
WILDERARCHITECTURE, INC. ADDENDUM ONE (01)
1315 East Seventh Avenue | Suite 106 Tampa, Florida 33605
(813) 242-6677 wilderarchitecture.com
AA26000655
16. Sheet No. S3.4 – SECTIONS & DETAILS FIRING RANGE
A. Revise Mechanical enclosure as shown in the revised sheet.
B. Revise sheet to include Details 4 & 4A – Southwest Corner of Gym Building – Gap Stabilization Detail.
17. Sheet No. P0.1 - PLUMBING GENERAL NOTES, LEGEND, AND SCHEDULES, replace sheet dated 1/16/17 with the Addendum One sheet dated 2/15/17.
18. Sheet No. P0.2 – PLUMBING DETAILS. Add sheet P0.2, dated 2/15/17.
19. Sheet No. P1.1 – PLUMBING PLANS, replace sheet dated 1/16/17 with the Addendum One sheet dated 2/15/17.
20. Sheet No. P2.1 – SANITARY AND DOMESTIC WATER ISOMETRICS, replace sheet dated 1/16/17 with the Addendum One sheet dated 2/15/17.
21. Sheet No. M1.1 – HVAC PLAN, replace sheet dated 1/16/17 with the Addendum One sheet dated 2/15/17.
22. Sheet No. M2.1 – HVAC SCHEDULES AND DETAILS, replace sheet dated 1/16/17 with the Addendum One sheet dated 2/15/17.
23. Sheet No. E0.1 - ELECTRICAL LEGEND AND GENERAL NOTES, replace sheet dated 1/16/17 with the Addendum One sheet dated 2/15/17.
24. Sheet No. E1.1 - LIGHTING PLANS - FIRING RANGE/GYM, replace sheet dated 1/16/17 with the Addendum One sheet dated 2/15/17.
25. Sheet No. E2.1 - POWER & DATA PLANS - FIRING RANGE/GYM, replace sheet dated 1/16/17 with the Addendum One sheet dated 2/15/17.
26. Sheet No. E3.1 - FIRE ALARM & SYSTEMS PLANS - FIRING RANGE/GYM, replace sheet dated 1/16/17 with the Addendum One sheet dated 2/15/17.
27. Sheet No. E4.1 - ELECTRICAL RISER DIAGRAMS, replace sheet dated 1/16/17 with the Addendum One sheet dated 2/15/17.
28. Sheet No. E5.1 - ELECTRICAL SCHEDULES - FIRING RANGE, replace sheet dated 1/16/17 with the Addendum One sheet dated 2/15/17.
29. Sheet No. E5.2 - ELECTRICAL SCHEDULES – GYM AND RISER DIAGRAM, replace sheet dated
1/16/17 with the Addendum One sheet dated 2/15/17. END OF ADDENDUM NO. ONE (01) / 1626-ADD-2017 02 15-HCSO Range & Gym Addendum 01.docx
WILDERARCHITECTURE, INC. ADDENDUM ONE (01)
1315 East Seventh Avenue | Suite 106 Tampa, Florida 33605
(813) 242-6677 wilderarchitecture.com
AA26000655
ATTACHMENTS
Specification Section 08 5659 – SERVICE WINDOW UNITS, dated 2/15/2017
Specification Section 31 3116 - TERMITE CONTROL, dated 2/15/2017
Drawings:
A1.2, A1.3, A1.4, A2.1, A4.1, A4.3, A7.1, A8.1, and A8.2 dated 2/15/2017
S2.1 and S3.4, dated 2/15/2017
P0.1, P0.2, P1.1, and P2.1, dated 2/15/2017
M1.1 and M2.1, dated 2/15/2017
E0.1, E1.1, E2.1, E3.1, E4.1, E5.1, and E5.2, dated 2/15/2017
HILLSBOROUGH COUNTY SHERIFF'S OFFICEFIRING RANGE AND WORKOUT GYM
FEBRUARY 15, 2017 ADDENDUM 01
PINEBROOKE BUSINESS PARK
SERVICE WINDOW UNITS 08 5659-1
SECTION 08 5659 - SERVICE WINDOW UNITS
PART 1 GENERAL1.1 SECTION INCLUDES
A. Service window units.B. Accessories.
1.2 RELATED REQUIREMENTSA. Section 07 9200 - Joint Sealants: Sealing joints between frames and adjacent construction.
1.3 REFERENCE STANDARDSA. AAMA 611 - Voluntary Specification for Anodized Architectural Aluminum.B. AAMA 2603 - Voluntary Specification, Performance Requirements and Test Procedures for Pigmented
Organic Coatings on Aluminum Extrusions and Panels (with Coil Coating Appendix).C. ASTM A123/A123M - Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel
Products.D. ASTM B221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire,
Profiles, and Tubes.E. ASTM B221M - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire,
Profiles, and Tubes [Metric].
1.4 ADMINISTRATIVE REQUIREMENTSA. Coordinate work with adjacent materials specified in other sections and as indicated on drawings and
approved shop drawings.B. Preinstallation Meeting: Prior to start of installation arrange a meeting on site to familiarize installer and
installers of related work with requirements relating to this work.
1.5 SUBMITTALSA. See Section 01 3000 - Administrative Requirements, for submittal procedures.B. Product Data: Submit manufacturer's product data for specified products indicating materials, operation,
glazing, finishes, and installation instructions.C. Shop Drawings: Indicate configuration, sizes, rough-in, mounting, anchors and fasteners, and installation
clearances.D. Samples for Selection of Finishes:
1. Applied Finishes: Color charts for factory finishes.E. Manufacturer Qualification Statement.F. Installer Qualification Statement.G. Warranty: Submit manufacturer warranty and ensure that forms have been completed in Hillsborough
County Sheriff's Office's name and registered with manufacturer.
1.6 QUALITY ASSURANCEA. Manufacturer Qualifications: Company specializing in manufacturing products specified in this section with
at least ten years documented experience, and with ability to provide test reports showing that theirstandard manufactured products meet the specified requirements.
1.7 DELIVERY, STORAGE, AND HANDLINGA. Deliver units in manufacturer's original packaging and unopened containers with identification labels intact.B. Store units in area protected from exposure to weather and vandalism.
1.8 WARRANTYA. See Section 01 7800 - Closeout Submittals, for additional warranty requirements.B. Provide manufacturer's warranty agreeing to repair or replace units and their components that fail in
materials or workmanship within two years from Date of Substantial Completion.
PART 2 PRODUCTS2.1 SERVICE AND TELLER WINDOW UNITS
A. Pass-Through Window:1. Location: Interior.2. Window: Single horizontal sliding.
a. Operation: Manual, self-closing.b. Mounting: Flush with the wall surface.c. Size: As indicated on drawings.d. Material: Aluminum.
HILLSBOROUGH COUNTY SHERIFF'S OFFICEFIRING RANGE AND WORKOUT GYM
FEBRUARY 15, 2017 ADDENDUM 01
PINEBROOKE BUSINESS PARK
SERVICE WINDOW UNITS 08 5659-2
e. Finish Color: As selected from manufacturer's standard colors.f. Sidelights: Size as indicated on drawings..
3. Glazing: 1/4", clear.a. Tempered safety glazing.
4. Communication: Standard talk-through portal.B. Manufacturer's:
1. Interbank Equipment; interbank-equipment.com2. C.R. Laurence Co. Inc.;crlaurance.com3. Substitutions: See Section 01 6000 - Product Requirements.
2.2 COMPONENTSA. Windows: Factory-fabricated, -finished, and -glazed, extruded aluminum frame and glazing stops; complete
with hardware and anchors.1. Provide window units that are re-glazable from the secure side without dismantling the non-secure side
of framing.2. Rigidly fit and secure joints and corners with internal reinforcement. Make joints and connections flush,
hairline, and weatherproof. Fully weld corners.3. Apply factory finish to all exposed surfaces.4. Self-Closing Operation: Manual open and self-closing with auto-locking handles and magnetic
hold-open device.
2.3 MATERIALSA. Aluminum Extrusions: Minimum 1/8 inch thick frame and sash material complying with ASTM B221 and
ASTM B221M.
2.4 FINISHESA. Pigmented Organic Coating System: AAMA 2603; polyester or acrylic baked enamel finish.B. Color: To be selected by Wilder Architecture, Inc. from manufacturer's standard range.
2.5 ACCESSORIESA. Hardware and Security Devices for Sliding Windows:
1. Auto-Lock Handle: Stainless steel auto-locking handle on all self-closing sliders to prevent intrusion.
PART 3 EXECUTION3.1 EXAMINATION
A. Verify that window openings are ready for installation of windows.B. Verify that correct embedded anchors are in place and in proper location; repair or replace anchors as
required to achieve satisfactory installation.C. Notify Wilder Architecture, Inc. if conditions are not suitable for installation of units; do not proceed until
conditions are satisfactory.
3.2 INSTALLATIONA. Install in accordance with manufacturer's instructions.B. Install units in correct orientation (inside/outside or secure/non-secure).C. Anchor units securely in manner so as to achieve performance specified.
3.3 ADJUSTINGA. Adjust operating components for smooth operation while also maintaining a secure, weather-tight enclosure
and a tight fit at the contact points; lubricate operating hardware.
3.4 CLEANINGA. Remove protective material from factory finished surfaces.B. Clean exposed surfaces promptly after installation without damaging finishes.
3.5 PROTECTIONA. Provide temporary protection to ensure that service and teller windows are without damage upon Date of
Substantial Completion.
END OF SECTION
HILLSBOROUGH COUNTY SHERIFF'S OFFICE FEBRUARY 15, 2017FIRING RANGE AND WORKOUT GYM ADDENDUM 01PINEBROOKE BUSINESS PARK
TERMITE CONTROL 31 3116-1
SECTION 31 3116 - TERMITE CONTROL
PART 1 - GENERAL1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions andDivision 1 Specification Sections, apply to this Section.
1.2 SUMMARYA. This Section includes the following for termite control:
1. Soil treatment.
1.3 DEFINITIONSA. EPA: Environmental Protection Agency.B. PCO: Pest control operator.
1.4 SUBMITTALSA. Product Data: Treatments and application instructions, including EPA-Registered Label.B. Product Certificates: Signed by manufacturers of termite control products certifying that treatments
furnished comply with requirements.C. Warranties: Special warranties specified in this Section.
1.5 QUALITY ASSURANCEA. Regulatory Requirements: Formulate and apply termiticides, and label with a Federal registration number,
to comply with EPA regulations and authorities having jurisdiction.B. Applicator of termite treatment shall contract directly with the GC or CM, not with a subcontractor.
1.6 PROJECT CONDITIONSA. Environmental Limitations: To ensure penetration, do not treat soil that is water saturated or frozen. Do not
treat soil while precipitation is occurring. Comply with EPA-Registered Label requirements andrequirements of authorities having jurisdiction.
B. Prior to each application, applicators must notify the construction superintendent of similar responsibleparty of the intended temiticide application and sites of application and instruct the responsible person tonotify workers and other individuals on site to leave the area to be treated during application until thetermiticide is absorbed into the soil
1.7 COORDINATIONA. Coordinate soil treatment application with excavating, filling, and grading and concreting operations. Treat
soil under footings, grade beams, and ground-supported slabs, before construction.
1.8 WARRANTYA. General Warranty: Special warranty specified in this Article shall not deprive Owner of other rights Owner
may have under other provisions of the Contract Documents and shall be in addition to, and run concurrentwith, other warranties made by Contractor under requirements of the Contract Documents.
B. Special Warranty: Written warranty, signed by applicator and Contractor certifying that termite control work,consisting of applied soil termiticide treatment, will prevent infestation of subterranean termites. Ifsubterranean termite activity or damage is discovered during warranty period, re-treat soil and repair orreplace damage caused by termite infestation.
C. Identification: the Warranty shall identify the chemical used and the building number(s) to which it wasapplied.
D. Warranty Period: Five years from date of Substantial Completion.
PART 2 - PRODUCTS2.1 SOIL TREATMENT
A. Termiticide: Provide one of the following non-repellant chemicals:1. Imidacloprid (such as Premise 75), diluted to the strongest allowable concentration according to the
manufacturer's written instructions.2. Fipronil (such as Termidor 80 WG), diluted to the strongest allowable concentration according to the
manufacturer's written instructions.
HILLSBOROUGH COUNTY SHERIFF'S OFFICE JANUARY 16, 2017FIRING RANGE AND WORKOUT GYM PERMIT SETPINEBROOKE BUSINESS PARK
TERMITE CONTROL 31 3116-2
PART 3 - EXECUTION3.1 EXAMINATION
A. Examine substrates, areas, and conditions, with Applicator present, for compliance with requirements formoisture content of the soil, interfaces with earthwork, slab and foundation work, landscaping, and otherconditions affecting performance of termite control. Proceed with application only after unsatisfactoryconditions have been corrected.1. Do not treat soil that is too moist or if there is standing water.
B. Product is to be delivered to the site in its original labeled containers.
3.2 PREPARATIONA. General: Comply with the most stringent requirements of authorities having jurisdiction and with
manufacturer's written instructions for preparing substrate. Remove all extraneous sources of woodcellulose and other edible materials such as wood debris, tree stumps and roots, stakes, formwork, andconstruction waste wood from soil and around foundations.
B. Soil Treatment Preparation: Remove foreign matter and impermeable soil materials that could decreasetreatment effectiveness on areas to be treated. Loosen, rake, and level soil to be treated, except previouslycompacted areas under slabs and footings. Termiticides may be applied before placing compacted fillunder slabs if recommended by termiticide manufacturer.
C. Fit filling hose connected to water source at the site with a backflow preventer, complying with requirementsof authorities having jurisdiction.
D. Prior to each application, applicator shall notify the Contractor of the intended termiticide application andintended sites of application and instruct the Contractor to notify workers and other individuals on site toleave the area to be treated during application and until the termiticide is absorbed into the soil.
E. Subcontractor shall mix the chemical on site from original, unopened, labeled containers. ConstructionManager is responsible for enforcing this requirement and verifying dilution rates.
F. Notify the School Board Inspections Department 48 hours prior to applying the chemical. Owner willobserve application.
3.3 APPLICATION, GENERALA. General: Comply with the most stringent requirements of authorities having jurisdiction and with
manufacturer's EPA-Registered Label for products.B. Scope: Protect against subterranean termites for all new construction and whenever the soil under existing
construction is disturbed.
3.4 APPLYING SOIL TREATMENTA. Application: Mix soil treatment termiticide solution to a uniform consistency. Provide quantity required for
application at the label volume and rate for the maximum specified concentration of termiticide, according tomanufacturer's EPA-Registered Label, to the following so that a continuous horizontal and verticaltermiticidal barrier or treated zone is established around and under building construction. Distribute thetreatment evenly.1. Slabs-on-Grade: Under ground-supported slab construction, including footings, building slabs, and
attached slabs as an overall treatment. Treat soil materials before concrete footings and slabs areplaced.
2. Foundations: Adjacent soil including soil along entire inside perimeter of foundation walls, along bothsides of interior partition walls, around plumbing pipes and electric conduit penetrating slab, and aroundinterior column footers, piers, and chimney bases; and along entire outside perimeter, from grade tobottom of footing. Avoid soil washout around footings.a. When treating foundations deeper than 4 feet, apply the termiticide as the backfill is being replaced,
or failing this, treat the foundation to a minimum depth of 4 feet after the backfill has been installedby trenching and rodding into the trench or trench along the foundation walls and around pillars andother foundation elements at the rate prescribed from grade to a minimum depth of 4 feet.
b. When the top of the footing is exposed, treat the soil adjacent to the footing to the bottom of thefooting. Do not treat below the footings.
3. Masonry: Treat CMU cells in stem walls to the top of the footing. Apply at the stongest allowableconcentration and rate according to manufacturer's instructions. Apply so that the emulsion will reachthe top of the footing.
4. Penetrations: At expansion joints, control joints, and areas where slabs will be penetrated.B. Horizontal Barriers: Create a horizontal barrier whenever treated soil will be covered, such as footing
trenches, slabs, and the soil beneath stairs, crawlspaces and sidewalks adjacent to the building.
HILLSBOROUGH COUNTY SHERIFF'S OFFICE JANUARY 16, 2017FIRING RANGE AND WORKOUT GYM PERMIT SETPINEBROOKE BUSINESS PARK
TERMITE CONTROL 31 3116-3
1. Apply at the stongest allowable concentration and rate according to manufacturer's instructions If the fillis washed gravel or other coarse material, apply a sufficient amount of dilution to reach the soilsubstrate beneath the coarse fill.
2. Applications shall be made per manufacturer's instructions. If slab will not be placed the same day astreatment, cover treated soil with a waterproof barrier such as polyethylene sheeting. If the slab is notplaced within 24 hours of treatment, re-treat the area.
C. Vertical Barriers: Create vertical barriers around the base of foundations, plumbing, utility entrances,back-filled soil against foundation walls and other critical areas.1. Apply 4 gallons of dilution per 10 linear feet per foot of depth to ensure complete coverage.2. When trenching and rodding into the trench, or trenching, ensure that the emulsion reaches the top of
the footing. Space rod holes to achieve a continuous termiticidel barrier, but in no case more than 12inches apart.
3. Avoid soil washouts around the footings.4. Trenches need not be wider than 6 inches. Emulsion shall be mixed with the soil as it is being replaced
in the trench.5. For a monolithic slab, an inside vertical barrier may not be required.6. Treat CMU stem walls at a rate of 2 gallons of emulsion per 10 linear feet so that the emulsion will reach
the top of the footing.D. Avoid disturbance of treated soil after application. Keep off treated areas until completely dry.E. Protect termiticide solution, dispersed in treated soils and fills, from being diluted until ground-supported
slabs are installed. Use waterproof barrier according to EPA-Registered Label instructions.F. Post warning signs in areas of application.G. Reapply soil treatment solution to areas disturbed by subsequent excavation, grading, landscaping, or other
construction activities following application or if not covered within 24 hours.H. Do not apply soil treatment if the ground conditions in the area to be treated are too moist or if standing
water is present.
END OF SECTION
X
X
X
X
X
ARMORY
605CTRL RM
604
FIRING RNG
603
OFFICE
607
CLEANING RM
612
WOMEN
609
TRAINING
614
CORR
613
15'-8" (V.I.F.)27'-4" (V.I.F.)
16'-1
7
16
" (V.I.F.)
11'-8"10'-0"2'-8"3'-4"
3'-4
3
8
"
3'-4"2'-8"10'-0"
12'-1
1
4
"
59'-1
7
16
" (V.I.F.)
29
'-5
1 2
" V
.I.F
.
30
'-0
" (V
.I.F
.)
25
'-4
" V
.I.F
.
29'-4" (V.I.F.)30'-0" (V.I.F.)
90
'-0
" (V
.I.F
.)
84
'-0
"
26'-8"
3'-1
1
7
16
"
8'-0"14'-8"
14
'-8
"
8'-8
"
WAITING
606
JAN
610
STOR
615
MEN
611
6'-9
1
2
"
10
'-3
7
16
"
600A
601
602
603604A
605
607
609
610
611
614A
615
613
604B604C
616A
616B
614C
9'-1
0
1 2
"
8'-0"
56
'-0
"
17'-4"
614B
3'-4"
1'-4"
3'-4"
1'-4"
8'-8"
1'-4"
3'-4" 3'-4"
608
CORR
613
612
5'-3
7
8
"
6'-0"
7'-3
7
8
"
6'-0
"
29
'-7
13
16
"
3'-4
"
P-8
P-2
P-2
P-2
P-13 P-12
P-18
P-19
P-10 P-11
VOID
616
W05W06
W04
W04
W04
W03
600B
W07
FE
-1
FE-2
P-2P-5
P-2
P-2
P-18
P-17
P-9
P-3
P-15
P-18
P-3
P-2
P-1
P-3
P-7
P-7 P-14 P-17 P-16P-7 P-6
P-2
P-16
P-19
1'-4
"
FE-2
1'-8
"
18
'-0
"
17'-4"
13
'-4
"1
3'-4
"1
'-4
"
4'-8
"
1'-4
"1
3'-4
"1
'-4
"
4'-8
"
16
'-0
"
4'-0"
1
600
A,B
A,C
A
A
A
A
A
A
A
A
A
A
1
1
1
1
1
1
1
1
1
1
1
ARMORY
605CTRL RM
604
FIRING RNG
603
OFFICE
607
CLEANING RM
612
WOMEN
609
TRAINING
614
CORR
613
WAITING
606
JAN
610
STOR
615
MEN
611
CORR
613
VOID
616
A,B
A,C
A
A
A
A
A
A
A
A
A
A
1
1
EQUIPMENT SCHEDULE
NUMBER DESCRIPTION
CP OP CI OI
CONTRACT STATUS REMARKS
C01
C02
C03
C04
C05
C06
C07
E01
E02
COUNTERTOP
FIXED SHELVING
FIXED SHELVING
WORKSTATIONS (SS COUNUTER TOP)
LAVATORY COUNTERTOP
LAVATORY COUNTERTOP
FIXED SHELVING W/ 4'X8'
WORKTABLE
SECURITY DRAWER
METAL LOCKERS, 2-TIER
SEE DETAIL A1/A8.1
SEE DETAIL E12/A8.1
SEE DETAIL E13/A8.1
SEE DETAIL J1/A8.1
SEE DETAIL E7/A8.1
SEE DETAIL E1/A8.1
SEE DETAIL A5/A8.1
SEE SPECIFICATIONS
PROVIDE 4" CONCRETE BASE
HIL
LS
BO
RO
UG
H C
OU
NT
Y S
HE
RIF
F'S
O
FF
IC
E
FIR
IN
G R
AN
GE
A
ND
W
OR
KO
UT
G
YM
PIN
EB
RO
OK
E B
US
IN
ES
S P
AR
K
HILLSBOROUGH COUNTY
SHERIFF'S OFFICE
2008 EAST 8TH AVENUE
TAMPA, FLORIDA 33605
1626-00
WIL
DE
R
PROJECT #:
DISTRIBUTION
TELEPHONE 813.242.6677
wilderarchitecture.com
FACSIMILE 813.242.6683
TAMPA, FLORIDA 33605.3607
1315 E. SEVENTH AVENUE
AR
CH
IT
EC
TU
RE
, IN
C.
SUITE 106
DATE
AA26000655
PERMIT SET 01/16/17
ADDENDUM 01 2/15/17
FIRING RANGE
FLOOR PLAN
A1.2
FLOOR PLAN - FIRING RANGE
A3
1/8" = 1'-0"
NOTES
A1
SPECIFIC NOTES
1. EXIST STL COL (TO REMAIN), TYP.
2. FUTURE COIL REPLACEMENT WALL BREAK - SEE
STRUTURAL
3. SLOPE CONC SLAB TOWARD OPENINGS FOR
DRAINAGE
4. EXIST STOREFRONT GLAZING SYSTEM, PROVIDE
BLACK-OUT FILM ON THE INSIDE FACE OF
WINDOWS AND CLERESTORY ABOVE PRIOR TO
CONSTRUCTION OF PARTITION.
5. GWB BULKHEAD @ 108'-0", TYP.
6. HVAC EQUIP FOR RANGE VENTILATION (BY
MEGGITT)
7. DUCTWORK TO RANGE (BY MEGGITT) PROVIDE
WALL PENETRATION AND SEALING FOR NEW
DUCTWORK (BY GC)
8. SHOOTING STALL (BY MEGGITT)
9. BULLET TRAP (BY MEGGITT)
10. NEW SPLIT-FACE CMU BASE AND ENCLOSURE
11. SAFETY CEILING (BY MEGGITT)
12. REDIRECTIVE GUARD (BY MEGGITT)
13. CONTAINMENT BAFFLE (BY MEGGITT)
14. TARGET TRACK SYSTEM (BY MEGGITT)
15. ACOUSTICAL ABSORPTION CEILING PROVIDED
FULL AREA OF RANGE (RM 603). INCLUDE
SUSPENDED 2'X2' COMMERCIAL GRID (BY GC),
2'X2'X1" TROY BOARD PANELS (BY MEGGITT), AND
6" TROY WOOL ABOVE CLG PANELS (BY MEGGITT).
16. HOLD MASONRY OFF EXIST WALL BY 2"
17. APC GRID AND CLG PANELS BY G.C.
18. HVAC
19. SUPPLY REGISTER (BY MEGGITT)
20. HANDRAIL, 1.5" OD - STL (PNT BLACK)
21. ANGLE CLG TO SUPPLY REGISTER HOUSING
22. CONC STEP/PAD - COORD ELEVATION WITH EXIST
GRADE.
23. AIR COMPRESSOR (TIE TO CLEANING ROOM).
24. PROVIDE POCKET IN APC FOR CLEARANCE FOR
OVERHEAD DOOR.
REFLECTED CEILING PLAN - FIRING RANGE
A9
1/8" = 1'-0"
4' 8'0 16'4' 8'0 16'
GENERAL NOTES
1. CONTRACTOR TO PROVIDE COORDINATION
BETWEEN THE EXIST RANGE (BY MEGGITT)
EQUIPMENT AND NEW CONSTRUCTION
REQUIREMENTS. MEGGITT WILL INSTALL ALL PRE
PURCHASED RANGE EQUIPMENT.
2. PARTITIONS ARE P-1 UNO.
3. CONTRACTOR SHALL CLEAN EXISTING
STOREFRONT, REPLACE WEATHERSTRIPPING,
SEALANT, DOOR HARDWARE AND EXIT DEVICES,
TYPICAL.
4. CONTRACTOR TO PROVIDE NEW HARDWARE AT
EXTERIOR HOLLOW METAL DOORS, INCLUDING
WEATHERSTRIPPING, AND THRESHOLDS. DOORS
AND FRAMES SHALL BE PREPARED AND PAINTED
AND SEALANT REPLACED.
BUILDING AREA
NOT IN SCOPE
A4.1
D3
A4.1
A3
A4.1
A11
3
2
EQUIPMENT SCHEDULE
J3
4
10
6
6
7
8
9
5
5
11
13
15
14
12
12
9
15
16
16
7
18
17
John W
. T
hom
pson, A
IA
AR
9
12
71
1/1
6/1
7
1
1
20
21
1
1
1
22
1
1
23
22
1
1
24
1
XX
BOXING TRN
707
ELEC RM
709
WEIGHT RM
700
LOCKER-M
704
LOCKER-W
702
24'-4"
10'-8" (V
.I.F
.)
27'-4" (V
.I.F
.)
16'-2
1 2
" (V
.I.F
.)
54'-2
1 2
" (V
.I.F
.)
4'-0"
88'-8" (V.I.F.)
700A
701
702
703
704
705
706 707A
708
700B
700C
707B
707C
9'-0" 15'-0"
5'-0"
29'-0"5'-4"
6'-0"
14'-0"
22'-0"
8'-0
7
16
"
10'-0"
8'-0"
25'-4" V.I.F.
VEST
703
VEST.
701
STOR
708
OFFICE
706
CORR.
710
709
FE
-2
FE
-1
JAN
705
W01
W02
P-3
P-7 P-7
P-4
P-4
P-7P-8
P-8
P-3
P-3
P-3
P-5
P-5
P-3
W01
P-7
P-8P-8
6'-0"
1
1
700D
12'-0"
A,B
A,C
A
A A
A
A
1
1
1
A
1
1
3
1
BOXING TRN
707
ELEC RM
709
WEIGHT RM
700
LOCKER-M
704
LOCKER-W
702
VEST
703
VEST.
701
STOR
708
OFFICE
706
CORR.
710
JAN
705
1
1
A,B
A,C
A
A A
A
A
1
1
1
A
1
1
3
1
EQUIPMENT SCHEDULE
NUMBER DESCRIPTION
CP OP CI OI
CONTRACT STATUS REMARKS
C01
C02
C03
C04
C05
C06
C07
E01
E02
COUNTERTOP
FIXED SHELVING
FIXED SHELVING
WORKSTATIONS (SS COUNUTER TOP)
LAVATORY COUNTERTOP
LAVATORY COUNTERTOP
FIXED SHELVING W/ 4'X8'
WORKTABLE
SECURITY DRAWER
METAL LOCKERS, 2-TIER
SEE DETAIL A1/A8.1
SEE DETAIL E12/A8.1
SEE DETAIL E13/A8.1
SEE DETAIL J1/A8.1
SEE DETAIL E7/A8.1
SEE DETAIL E1/A8.1
SEE DETAIL A5/A8.1
SEE SPECIFICATIONS
PROVIDE 4" CONCRETE BASE
HIL
LS
BO
RO
UG
H C
OU
NT
Y S
HE
RIF
F'S
O
FF
IC
E
FIR
IN
G R
AN
GE
A
ND
W
OR
KO
UT
G
YM
PIN
EB
RO
OK
E B
US
IN
ES
S P
AR
K
HILLSBOROUGH COUNTY
SHERIFF'S OFFICE
2008 EAST 8TH AVENUE
TAMPA, FLORIDA 33605
1626-00
WIL
DE
R
PROJECT #:
DISTRIBUTION
TELEPHONE 813.242.6677
wilderarchitecture.com
FACSIMILE 813.242.6683
TAMPA, FLORIDA 33605.3607
1315 E. SEVENTH AVENUE
AR
CH
IT
EC
TU
RE
, IN
C.
SUITE 106
DATE
AA26000655
PERMIT SET ADDENDUM 01
ADDENDUM 01 2/15/17
WORKOUT GYM
FLOOR PLAN
A1.3
NOTES
A1
GENERAL NOTES
1. CONTRACTOR TO PROTECT ALL EXIST FINISHES
DURING CONSTRUCTION.
2. CONTRACTOR SHALL CLEAN EXISTING
STOREFRONT, REPLACE WEATHERSTRIPPING,
SEALANT, DOOR HARDWARE AND EXIT DEVICES,
TYPICAL.
3. CONTRACTOR TO PROVIDE NEW HARDWARE AT
EXTERIOR HOLLOW METAL DOORS, INCLUDING
WEATHERSTRIPPING, AND THRESHOLDS. DOORS
AND FRAMES SHALL BE PREPARED AND PAINTED
AND SEALANT REPLACED.
4. COORDINATE DEMOLITION OF EXIST CONDITIONS
WITH SCOPE SHOWN.
SPECIFIC FLOOR PLAN NOTES
1. EXIST STL COL, TYP.
2. EXIST VERTICAL BLINDS TO BE REPLACED.
3. EXIST DEMISING WALL
4. ADJUST DEPTH OF FURRING TO MATCH EXIST
PLANE w/ FULL CLG PANEL ABOVE.
5. BULKHEAD ELEV - 11'-8" AFF
6. BULKHEAD ELEV - 8'-8" AFF
7. PROVIDE WOOD BLOCKING @ 9'-0" AFF FOR
OWNER PROVIDED AND INSTALLED FAN.
8. PROVIDE POCKET IN APC FOR CLEARANCE FOR
OVERHEAD DOOR.
FLOOR PLAN - WORKOUT GYM
A3
1/8" = 1'-0"
4' 8'0 16'
REFLECTED CEILING PLAN - WORKOUR GYM
A3
1/8" = 1'-0"
4' 8'0 16'
BUILDING AREA
NOT IN SCOPE
A4.1
D11
EQUIPMENT SCHEDULE
J3
2
1
1
44
4
4
4
4
6
2
7
4
John W
. T
hom
pson, A
IA
AR
9
12
71
1/1
6/1
7
1
7
7
7
7
1
1
1
1
# A
RM NUMBER
SIGN TYPE REQUIRED
8
1
6"
1
20
'-2
3 8
"
4'-0
"
VE
RIF
Y
P
RIO
R
TO
D
EM
O
41
'-1
0"
4'-0
"
VE
RIF
Y
P
RIO
R
TO
D
EM
O
HIL
LS
BO
RO
UG
H C
OU
NT
Y S
HE
RIF
F'S
O
FF
IC
E
FIR
IN
G R
AN
GE
A
ND
W
OR
KO
UT
G
YM
PIN
EB
RO
OK
E B
US
IN
ES
S P
AR
K
HILLSBOROUGH COUNTY
SHERIFF'S OFFICE
2008 EAST 8TH AVENUE
TAMPA, FLORIDA 33605
1626-00
WIL
DE
R
PROJECT #:
DISTRIBUTION
TELEPHONE 813.242.6677
wilderarchitecture.com
FACSIMILE 813.242.6683
TAMPA, FLORIDA 33605.3607
1315 E. SEVENTH AVENUE
AR
CH
IT
EC
TU
RE
, IN
C.
SUITE 106
DATE
AA26000655
ADDENDUM 01 2/15/17
DEMOLITION PLAN
A1.4
NOTES
A1
GENERAL NOTES
1. CAP ALL UNUSED PLUMBING LINES, TYP.
2. PROTECT EXISTING COL. AND FTG. TO REMAIN
DURING DEMO, TYP.
3. ALL MECHANICAL EQUIPMENT AND DUCTWORK IN
GYM AREA AND RANGE AREA SHALL BE
COMPLETELY REMOVED.
4. ALL DUCTWORK IN GYM AREA AND RANGE AREA
SHALL BE COMPLETELY REMOVED, CAP AND SEAL
ALL ABANDONED ROOF OPENINGS AIR TIGHT, TYP.
5. REMOVE ABANDONED WIRING U.N.O., TYP.
6. CUT, CAP, AND PATCH CONCEALED CONDUITS AT
POINTS OF EMERGENCE, TYP.
7. G.C. TO COORD SCOPE WITH WORK PROVIDED BY
OTHERS IN RANGE SCOPE. REFER TO MOST
RECENT DRAWINGS BY MEGGITT AND CAREYS.
8. REMOVE EXIST FLR FIN AT AREAS TO BE
RENOVATED.
9. PROVIDE COMPACTED GRADE, TERMITICIDE, AND
UNDERSLAB VAPOR RETARDER.
10. PROPERLY TERMINATE WATER SUPPLY LINES,
TYP.
DEMOLITION NOTES
1. REMOVE EXIST CONC SLAB AND EXIST
UNDERSLAB VAPOR RETARDER, TYP.
2. CUT AND CAP ALL EXIST ABANDONED SANITARY
PIPING BELOW FLOOR SLAB, TYP. REPAIR SLAB.
3. REMOVE EXIST STL COL.
4. REMOVE EXIST INFILL WALL TO INSTALL NEW
DOOR
5. REMOVE EXIST FLOORING FINISH, TYP.
6. PROPERLY TERMINATE SUPPLY LINES, TYP.
7. REMOVE EXIST UNUSED EQUIP FROM WALL
PENETRATIONS, REPAIR CMU TO MATCH EXIST,
TYP.
8. CUT OPENING IN CMU FOR NEW MECH EXHAUST
DUCTS. COORD ELEV WITH CAREY'S.
9. CUT EXISTING SLAB FOR NEW CMU WALL FTGS,
REFER TO STRUCTURAL SHEETS FOR DIMS.
10. CUT AND CAP EXIST ABANDONED POTABLE
WATER LINES AT MAIN LINE AND PROVIDE SHUT
OFF VALVE, TYP.
11. EXIST DEMISING WALL - MAINTAIN / REPAIR RATED
ASSEMBLY, TYP.
12. EXIST MVCJ TO REMAIN.
13. COORD NEW FTG W/ EXIST FTG, TYP.
14. REMOVE CONC SLAB AS REQ TO INSTALL NEW
PLUMBING SCOPE.
15. EXIST EXT CONDUIT TO REMAIN.
16. REMOVE / ABANDON EXIST FTGS AS REQ TO
INSTALL NEW SLAB.
17. EXIST COL TO REMAIN.
18. REPLACE CMU (SPLITFACE) AT WALL OPENINGS
NOT NEEDED.
19. EXIST CONC FTG TO REMAIN.
20. REPAIR CORNER AS SHOWN IN STRUCTURAL
DRAWING 4/S3.4.
21. CLOSE OFF DECK TO CMU WALL INTERFACE AT
TOP OF WALL, TYP. AT PERIMETER.
22. REMOVE EXIST HM DOOR AND FRAME.
23. REMOVE EXIST ALUM DOOR.
DEMO PLAN - WORKOUT GYM
A8
1/8" = 1'-0"
4' 8'0 16'
DEMO PLAN - FIRING RANGE
A3
1/8" = 1'-0"
4' 8'0 16'
BUILDING AREA
NOT IN SCOPE
2
4
3
3
3
3
5
1
5
2 6
6
7
8
8
9
9
9
9
10
10
9
TYP.
19
17
21
20
TYP.
11
18
16
16
16
16
13
11
14
14
13
12
15
1
1
22
23
23
23
FLOOR SLAB REPLACEMENT
1. REMOVE AND REPLACE EXIST CONC SLAB ON
GRADE. PROVIDE TERMITE TREATMENT.
PROVIDE UNDERSLAB VAPOR RETARDER.
2. SLAB THICKNESS SHALL MATCH THE THICKNESS
OF THE EXIST SLAB REMOVED.
3. SEE "SLAB ON GRADE NOTES" S1.1 FOR SLAB
INFORMATION.
4. PROVIDE CONTROL JOINTS AT 12' O.C. MAXIMUM.
SEE DETAIL 5 / S3.1 FOR CONTROL JOINT DETAIL.
5. PROVIDE 1/2" EXPANSION MATERIAL BETWEEN
WALL AND SLAB AROUND PERIMETER AT OUTSIDE
WALL AND AROUND COLUMNS.
6. SEE DETAIL 7 / S3.3 FOR DOWELS AT INTERIOR
WALL FOR NEW SLAB TO EXISTING SLAB
CONNECTION.
FE
-1
FE-2
10'-4" 5'-8"
10'-0"
6'-0"
10'-0"
1'-6"
6"
1'-0"
1'-8
3
4
"
4'-5
1
2
"
1'-0"
6"
1'-6"
EQ EQ
1'-6"
7"
FE
-2
FE
-1
1'-8"EQEQEQ
1'-8"
14'-0"6'-0"17'-11"
EQ EQ EQ EQ
1'-7"3'-0"3'-0"
1'-6"
1'-6"
1'-6"
3'-2"3'-2"3'-2"5'-1"
1'-7
1
2
"
1'-6"
1'-7
1
4
"3'-3
1
2
"
5'-1"
1'-7
1
4
"
8'-0"
6'-0"
6'-0"
2'-0"
7'-6
5 8
"
6'-0"11'-0"
12'-0"
3'-0"
4'-0"
1'-0"
2'-6" 3'-0" 3'-0" 2'-6"
3'-7"
5'-11
1
2
" 4'-7
1
2
"
2'-4" 8" 2'-4"
4" 2
1
2
"
TOILET ACCESSORY SCHEDULE
NUMBER DESCRIPTION REMARKS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
42" GRAB BAR
36" GRAB BAR
48" GRAB BAR
SOAP DISPENSER
TOILET PAPER DISPENSER
FRAMED MIRROR, 18" X 60"
ELECTRIC HAND DRYER
24" GRAB BAR
FRAMED MIRROR
SANITARY NAPKIN DISPOSAL UNIT
MOP AND BROOM HOLDER
UNDERCOUNTER LAVATORY GUARD
STAINLESS STEEL PANEL
SANITARY NAPKIN DISPENSER
TOILET SEAT COVER DISPENSER
ROBE HOOK
MOUNT 34" AFF
MOUNT 34" AFF
MOUNT 34" AFF
MOUNT ABOVE LAVATORY
--
BOTTOM EDGE OF MIRROR 10" AFF
--
MOUNT 34" AFF
LENGTH TO EQUAL COUNTERTOP. HIEGHT FROM
TOP OF COUNTER TO 7'0"AFF
--
--
--
PROVIDE AND INSTALL STAINLESS STEEL PANEL
SURROUND AT MOP SINK TO 5'-0" AFF
--
--
--
26"
34"
36"
12"
MAX
54"
MIN
2'-8
"
1'-6"
29" M
IN
.
34" M
AX
3'-4" T
O
RE
FLE
CT
IV
E
SU
RF
AC
E, T
YP
.
3'-0"
18"
42"
34"
19"
2'-10"
6"4'-0"6"
6'-6"
1'-2"
4'-7"
1'-1"
1'-5"
3'-6"
1'-5"
5"
2'-8"
1'-2"
4'-7"
1'-1"
6'-4"
26"
34"
36"
12"
MAX
54"
MIN
26"
34"
36"
12"
MAX
54"
MIN
TILE
6'-4"
TILE
6'-4"
TILE
6'-4"
TILE
6'-4"
HIL
LS
BO
RO
UG
H C
OU
NT
Y S
HE
RIF
F'S
O
FF
IC
E
FIR
IN
G R
AN
GE
A
ND
W
OR
KO
UT
G
YM
PIN
EB
RO
OK
E B
US
IN
ES
S P
AR
K
HILLSBOROUGH COUNTY
SHERIFF'S OFFICE
2008 EAST 8TH AVENUE
TAMPA, FLORIDA 33605
1626-00
WIL
DE
R
PROJECT #:
DISTRIBUTION
TELEPHONE 813.242.6677
wilderarchitecture.com
FACSIMILE 813.242.6683
TAMPA, FLORIDA 33605.3607
1315 E. SEVENTH AVENUE
AR
CH
IT
EC
TU
RE
, IN
C.
SUITE 106
DATE
AA26000655
PERMIT SET 1/16/2017
ADDENDUM 01 02/15/17
AND ELEVATIONS
ROOM PLANS
ENLARGED TOILET
A2.1
ENLARGED PLAN - TOILET ROOMS
A3
1/4" = 1'-0"
NOTES
A1
SPECIFIC FLOOR PLAN NOTES
1. CERAMIC WALL TILE TO 6'-4" AFF
2. CERAMIC WALL TILE FULL HT
3. 2-TIER WARDROBE LOCKER
4. PLASTIC LAMINATE TOILET PARTITIONS
5. SOLID PHENOLIC SHOWER PARTITIONS. SHOWER
UNITS SHALL INCLUDE COAT HOOK, SHOWER
ROD, SHOWER CURTAIN, GRAB BARS AT
ACCESSIBLE SHOWER AND SOAP DISH
6. EXIST STL COL
7. 4" CONC BASE w/ BASE
8. CLOSURE PANEL AT LOCKER END, TYP.
2' 4'0 8'
GENERAL NOTES
1. REMOVE EXIST SLAB AS REQUIRED TO INSTALL
NEW PLUMBING SLOPES
ENLARGED PLAN - LOCKER ROOMS
A6
1/8" = 1'-0"
TOILET ROOM ELEVATION
F1
3/8" = 1'-0"
SCHEDULE
A12
TOILET ROOM ELEVATION
H1
3/8" = 1'-0"
TOILET ROOM ELEVATION
F6
3/8" = 1'-0"
TOILET ROOM ELEVATION
F10
3/8" = 1'-0"
TOILET ROOM ELEVATION
H8
3/8" = 1'-0"
TOILET ROOM ELEVATION
K1
3/8" = 1'-0"
TOILET ROOM ELEVATION
K6
3/8" = 1'-0"
TOILET ROOM ELEVATION
K8
3/8" = 1'-0"
TOILET ROOM ELEVATION
K11
3/8" = 1'-0"
A2.1
K1
A2.1
K6
K11
K1
A2.1
K8
1
TYP.
1
TYP.
1
TYP.
1
TYP.
2
2
3
3
4
4
4
4
5
5
6
A2.1
F10
F6
F1
-
A2.1
H1
-
H8
-
8
8
37
37
John W
. T
hom
pson, A
IA
AR
9
12
71
1/1
6/1
7
1
1
1
1
2
1
5
6
7
89
3
12
TOP OF MASONRY
123'-4"
JOIST
TOP OF CMU
114'-0"
112'-0"
EXIST JOIST
VARIES (VIF)
EXIST SLAB
100'-0"
TOP OF CMU
105'-4"
4
18
19
11
MECH SLAB
99'-4"
10
20
22
23
24 24
17'-4"
4'-0"
21
90'-0"
30'-0" 30'-0"
11'-0"
J
J
TOP OF MASONRY
123'-4"
JOIST
TOP OF CMU
114'-0"
112'-0"
EXIST JOIST
121'-6"
SLAB
100'-0"
CTR. RM FLOOR
101'-9"
CTR. RM CEILING
109'-9"
30'-0"
EXIST OH DOOR
112'-0"
2
1
2
5
6
7
14
9
3
15
4
16
9
30
9
18
50'-0"
17
27
28
29
17
TOP OF EXIST
123'-4"
JOIST
TOP OF CMU
114'-0"
112'-0"
EXIST JOIST
121'-6"
SLAB
100'-0"
CLG
109'-0"
25
24
25
26
HIL
LS
BO
RO
UG
H C
OU
NT
Y S
HE
RIF
F'S
O
FF
IC
E
FIR
IN
G R
AN
GE
A
ND
W
OR
KO
UT
G
YM
PIN
EB
RO
OK
E B
US
IN
ES
S P
AR
K
HILLSBOROUGH COUNTY
SHERIFF'S OFFICE
2008 EAST 8TH AVENUE
TAMPA, FLORIDA 33605
1626-00
WIL
DE
R
PROJECT #:
DISTRIBUTION
TELEPHONE 813.242.6677
wilderarchitecture.com
FACSIMILE 813.242.6683
TAMPA, FLORIDA 33605.3607
1315 E. SEVENTH AVENUE
AR
CH
IT
EC
TU
RE
, IN
C.
SUITE 106
DATE
AA26000655
PERMIT SET 1/16/17
ADDENDUM 01 2/15/17
BUILDING SECTION
A4.1
NOTES
A1
GENERAL NOTES
1. EXIST BLDG ENVELOPE TO REMAIN.
2. EXIST ROOF SYSTEM TO REMAIN.
3. PROVIDE DUCTWORK PENETRATIONS TO INSTALL
RANGE SUPPLY AND EXHAUST.
SPECIFIC NOTES
1. EXIST STL JST, TYP.
2. MTL DECK W/ SOUND ATTENUATION INSULATION
(TROY WOOL 6") AND TROY BOARD PANELS (2") -
BY GC.
3. STL JOIST W/ MTL DECK
4. LANE DIVIDERS
5. 2" SOUND ATTENUATION BOARD
6. CMU WALL, GROUT SOLID, TYP.
7. EXIST CMU WALL
8. EXIST CONC SLAB
9. CONC FTG.
10. SPLIT FACE CMU.
11. CONC FLUME
12. EXIST GRADE
13. CONC FTG
14. CONTROL ROOM RAISED FLOOR (ACCESS
FLOORING), TYP.
15. CONTROL COMPUTER, OWNER PROVIDED
16. BULLET TRAP
17. DUCTWORK FOR RANGE (BY MEGGITT)
18. FIRING RANGE BAFFLE
19. STL COL, BEYOND.
20. SCUPPER
21. CONC HOUSE KEEPING PAD.
22. ADJACENT TENANT SPACE
23. SELF-ADHERING SHEET WATERPROOFING
24. EXTEND RATED PARTITIONS THE FULL HEIGHT OF
THE SPACE TO DECK ABOVE, TYP.
25. GWB SOFFIT/BULKHEAD, TYP.
26. GWB CONTROL JOINT, TYP. EXTEND AROUND
PERIMETER OF ROOM(S) SHOWN, TYP.
27. CLG GRID SYSTEM (BY GC) WITH TROY BOARD 2' X
2' X 1" PANELS AND 6" TROY WOOL (BY MEGGITT)
28. INTERSTITIAL SPACE ABOVE RANGE, WITHIN
ENVELOPE.
29. SAFETY CEILING (BY MEGGITT)
30. APC GRID AND PANELS (BY GC)
31. PROVIDE OPENINGS FOR NEW DUCTWORK
THROUGH WALL. PROVIDE LINTEL. SEAL
OPENING TIGHT TO DUCTWORK. PROVIDE SS
SHROUD TO COVER PENETRATION OF DUCT.
FIRING RANGE SECTION
A3
1/8" = 1'-0"
FIRING RANGE SECTION
A11
1/8" = 1'-0"
FIRING RANGE SECTION
D3
1/8" = 1'-0"
WORKOUT GYM SECTION
D11
1/8" = 1'-0"
A4.2
A5
A4.2
A1
4' 8'0 16'
4' 8'0 16'
John W
. T
hom
pson, A
IA
AR
9
12
71
1/1
6/1
7
1
1/32"
1
1
DOOR SCHEDULE
OPENING
NUMBER
ROOM NAME
TYPE MATL INT EXT
DOOR
TYPE MATL
HEAD JAMB SILL
DETAILS
FRAME FIRE
RATING
HDW
SET
REMARKS
600
600A
600B
601
602
603
604A
604B
604C
605
607
608
609
610
611
612
613
614A
614B
614C
615
616A
616B
700A
700B
700C
700D
701
702
703
704
705
706
707A
707B
707C
708
709
MECHANICAL YARD
ENTRY
ENTRY
VEST
READY RM
FIRING RNG
CTRL RM
CTRL RM
CTRL RM
ARMORY
OFFICE
CORR
WOMEN
JAN
MEN
CLEANING RM
CORR
TRAINING
TRAINING
TRAINING
STOR
VOID
VOID
WEIGHT RM
WEIGHT RM
WEIGHT RM
WEIGHT RM
VEST.
VEST.
VEST
LOCKER-M
JAN
OFFICE
BOXING TRN
BOXING TRN
BOXING TRN
ELEC RM
STOR
D05
D06
EXIST
D02
D01
D01
D01
D04
D04
D03
D02
D01
D02
D02
D02
D02
EXIST
D02
D02
EXIST
D04
EXIST
EXIST
D06
D06
D05
D04
D01
D01
D01
D01
D01
D01
D01
D05
EXIST
D01
D01
STL
ALUM
ALUM
WD
WD
WD
WD
WD
WD
WD
WD
WD
WD
WD
WD
WD
STL
WD
WD
STL
WD
STL
STL
ALUM
ALUM
STL
WD
WD
WD
WD
WD
WD
WD
WD
STL
STL
WD
WD
F03
EXIST
EXIST
F04
F03
F03
F03
F06
F06
F05
F02
F01
F02
F02
F02
F02
EXIST
F02
F02
EXIST
F06
EXIST
EXIST
EXIST
EXIST
F03
F06
F01
F01
F01
F01
F01
F01
F01
F03
EXIST
F01
F01
STL
ALUM
ALUM
STL
STL
STL
STL
STL
STL
STL
STL
STL
STL
STL
STL
STL
STL
STL
STL
STL
STL
STL
STL
ALUM
ALUM
STL
STL
STL
STL
STL
STL
STL
STL
STL
STL
STL
STL
STL
--
--
--
H9/A5.1
H9/A5.1
A9/A5.1
A9/A5.1
H12/A5.1
H12/A5.1
H5/A5.1
H12/A5.1
H12/A5.1
H12/A5.1
H12/A5.1
H12/A5.1
H12/A5.1
--
H12/A5.1
H12/A5.1
--
H12/A5.1
--
--
--
--
H5/A5.1
H12/A5.1
H12,A5.1
H12,A5.1
H12/A5.1
H1/A5.1
H12/A5.1
H12/A5.1
H12/A5.1
--
--
H12/A5.1
H12/A5.1
--
--
--
D9/A5.1
D9/A5.1
A5/A5.1
A5/A5.1
D13/A5.1
D13/A5.1
D5/A5.1
D13/A5.1, A5/A5.2
A1,D1/A5.2
D13/A5.1, D1/A5.2
D13/A5.1,A1/A5.2
D13/A5.1
D13/A5.1, D1/A5.2
--
D13/A5.1,D1/A5.2
D13/A5.1
--
D13/A5.1
--
--
--
--
D5/A5.1
D13/A5.1
D13/A5.1,D1/A5.2
D13/A5.1,D1/A5.2
D13/A5.1,D1/A5.2
D13/A5.1,A1/A5.2
D13/A5.1,A1/A5.2
D13/A5.2,G1/A5.2
D13/A5.2,G1/A5.2
--
--
D13/A5.1,D1/A5.2
D13/A5.1
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
20 MIN
--
--
--
--
--
20 MIN
20 MIN
--
20 MIN
20 MIN
20 MIN
20 MIN
--
20 MIN
20 MIN
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
06
01
12
07
09
10
08
02
02
06
04
09
07
06
07
07
01
07
07
--
03
01
EXIST
01
01
01
03
11
11
11
11
06
05
09
01
01
06
06
4
10
8
8
8,9,11
8,9,11
--
--
--
--
--
--
--
--
--
3,4
--
--
2,7
--
8,9
--
4
4
4,5,8
--
--
--
--
--
--
6
6
4,5,8
2,7
--
--
FINISH SCHEDULE
ROOM
NUMBER
ROOM NAME FLOOR BASE
SOUTH EAST WEST NORTH
WALLS
HEIGHT FINISH
CEILING
FINISH
REMARKS
600
601
602
603
604
605
606
607
609
610
611
612
613
614
615
616
700
701
702
703
704
705
706
707
708
709
710
ENTRY
VESTIBULE
READY ROOM
FIRING RANGE
CONTROL ROOM
ARMORY
WAITING AREA
OFFICE
WOMEN
JANITOR
MEN
CLEANING ROOM
CORRIDOR
TRAINING ROOM
STORAGE
VOID
WEIGHT ROOM
VESTIBULE
WOMEN'S LOCKER/SHOWER
VESTIBULE
MENS LOCKER/SHOWER
JANITOR
OFFICE
BOXING TRAINING ROOM
STORAGE
ELECTRICAL ROOM
CORRIDOR
LVT
LVT
LVT
LVT/SC
CPT
LVT
LVT
CPT
PT
LVT
PT
LVT
LVT
LVT
LVT
EXIST
LVT/RF
PT
PT
PT
PT
LVT
CPT
RF
LVT
LVT
LVT
RWB
RWB
RWB
(B.O.)
RWB
RWB
RWB
RWB
PT
RWB
PT
RWB
RWB
RWB
RWB
--
RWB
PT
PT
PT
PT
RWB
RWB
RWB
RWB
RWB
RWB
PNT
PNT
PNT
TROY
PNT
PNT
PNT
PNT
PT
PNT
PT
PNT
PNT
PNT
PNT
--
PNT
PNT
PT
PNT
PT
PNT
PNT
PNT
PNT
PNT
PNT
PNT
PNT
PNT
TROY
PNT
PNT
PNT
PNT
PT
PNT
PT
PNT
PNT
PNT
PNT
--
PNT
PNT
PT
PNT
PT
PNT
PNT
PNT
PNT
PNT
PNT
PNT
PNT
PNT
TROY
PNT
PNT
PNT
PNT
PT
PNT
PT
PNT
PNT
PNT
PNT
--
PNT
PNT
PT
PNT
PT
PNT
PNT
PNT
PNT
PNT
PNT
PNT
PNT
PNT
TROY
PNT
PNT
PNT
PNT
PT
PNT
PT
PNT
PNT
PNT
PNT
--
PNT
PNT
PT
PNT
PT
PNT
PNT
PNT
PNT
PNT
PNT
9'-0"
9'-0"
9'-0"
--
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
10'-0"
9'-0"
--
12'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
13'-6"
9'-0"
9'-0"
9'-0"
APC-1
APC-1
APC-1
APC-3
APC-1
APC-1
APC-1
APC-1
APC-2
APC-2
APC-2
APC-1
APC-1
APC-1
APC-1
--
APC-1
APC-1
APC-2
APC-1
APC-2
APC-2
APC-1
APC-1
APC-1
APC-1
APC-1
-
-
-
2,3,5,8
7
-
-
-
1
-
1
-
-
-
-
-
4
-
1
-
1
-
-
4
-
-
4
APC-1 ACOUSTICAL PANEL CEILING
APC-2 MOISTURE RESISTANT PANEL CEILING
APC-3 SUSPENDED GRID, PANELS, AND ACOUSTIC
INSUL (BY MEGGITT)
CONC CONCRETE
CPT CARPET TILE
CT CERAMIC TILE
EP EPOXY PAINT
LVT LUXURY VINYL TILE
NR NONE REQUIRED
PNT PAINTED GYPSUM WALLBOARD
PT PORCELAN TILE
RF RUBBER FLOORING
RWB RESILIENT WALL BASE
VWB VINYL WALL BASE
SC SEALED CONCRETE
TROY TROY BOARD (BY MEGGIT)
FINISH SCHEDULE ABBREVIATIONS
1. PROVIDE PORCELAIN TILE TO 6'-4" AFF (FULL HEIGHT @ SHOWERS).
2. PROVIDE LVT UP TO FIRING LINE.
3. PROVIDE SOUND ATTENUATION BLANKETS IN WALL BETWEEN ADJACENT ROOMS DESIGNATED.
4. IMPACT RESISTANT GWB
5. PROVIDE AIR SEALS AT DOORS
6. EPOXY PT
7. RAISED FLOORING
8. EPOXY SEAL ALL CONTROL/ EXPANSION JTS IN RANGE FLR.
REMARKS
REMARKS
1. PAIR OF DOORS.
2. OVERHEAD DOOR.
3. PNT EXIST DOOR
4. PROVIDE NEW HARDWARE TO MATCH
EXISTING HARDWARE,
WEATHERSTRIPPING, PERIMETER
SEALANT AND THRESHOLD.
5. INSULATED DOOR
6. COORDINATE STUD WALL THICKNESS
7. SECURE OH DOOR IN LOCKED POSITION
8. GROUT FRAME SOLID AT CMU
9. BULLET RESISTANT FRAME, DOOR,
GLAZING
10. SECURE DOOR IN LOCKED POSITION
11. PROVIDE SOUND SEALS
1. PROVIDE CRACK SUPPRESSION
MEMBRANE AT TILE FLOOR
LOCATIONS.
2. PROVIDE (RWB)RESILIENT WALL
BASE AT CASEWORK TOE KICKS,
TYP.
NOTES
1
1
1
11
1
1
7'-0"
3'-0"
D01
D03
D04
2'-6" PR
4'-0"
3'-2"
4'-0"
W01
4'-0"
3'-4"
W02
1'-6"
2" TYP.
8'-8"
4'-8"
3'-4"
W05
2" TYP.
D0220 MIN
20 MIN
W04
2"
7'-2"
2"
7'-0"
3'-4"
2"
F01
2"
7'-2"
2"
7'-0"
3'-0"
2"
3'-10"
3'-0"
2"
G1
G1
4"
7'-4"
2"
7'-0"
2"
F03
F02
3'-4"
3'-4"
4'-4"
F05
F07
5'-7"
20 MIN20 MIN
F0420 MIN
4'-0"
4'-8"
3'-4"
W06
HMF
2" TYP.
5'-4"
4'-8"
3'-4"
W07
F06
5'-4"
G3
G2
G1
G2G1
HMF HMFALUM
HMF HMFHMF
HORIZONTAL
SLIDING
WINDOW
LVL-3 LVL-3
G3
3'-2"
W03
7'-0"
3'-0"
D05
7'-0"
3'-0"
D06
WD HMF ALUM
(CONFIGURATION TO
MATCH EXIST BLDG
DOORS)
G1
1
2'-8"
FIXED
1
603
4"
1 2
"
1 2
"
DOOR SWEEP
ALUMINUM THRESHOLD
PAVING EXPANSION JOINT
CONCRETE FLOOR OR PAVING SLAB
CONCRETE FLOOR SLAB
DOOR
2" X 1/2" MARBLE
SADDLE
PORCELAIN
FLOOR TILE
CONCRETE SLAB
RUBBER FLOORING
1 2
"
DOOR
DOOR SWEEP
ALUMINUM THRESHOLD
PAVING EXPANSION JOINT
CONCRETE FLOOR OR PAVING SLAB
CONCRETE FLOOR SLAB
PORCELAIN TILE
DOOR
2" X 1/2" MARBLE
SADDLE
PORCELAIN
FLOOR TILE
CONCRETE SLAB
PORTLAND CEMENT
MORTAR BED
DOOR
CERAMIC TILE
6"
4
1 4
"
1 2
"
B
18" TO EDGE OF
DOOR FRAME
48
" T
O F
IN
IS
H
FL
OO
R
1 4
"
1 4
"
1 2
"
3 4
"
6"
4
1 4
"
1 2
"
C
18" TO EDGE OF
DOOR FRAME
48
" T
O F
IN
IS
H
FL
OO
R
1 4
"
1 4
"
1 2
"
3 4
"
4"
A
3"
1 2
"
HIL
LS
BO
RO
UG
H C
OU
NT
Y S
HE
RIF
F'S
O
FF
IC
E
FIR
IN
G R
AN
GE
A
ND
W
OR
KO
UT
G
YM
PIN
EB
RO
OK
E B
US
IN
ES
S P
AR
K
HILLSBOROUGH COUNTY
SHERIFF'S OFFICE
2008 EAST 8TH AVENUE
TAMPA, FLORIDA 33605
1626-00
WIL
DE
R
PROJECT #:
DISTRIBUTION
TELEPHONE 813.242.6677
wilderarchitecture.com
FACSIMILE 813.242.6683
TAMPA, FLORIDA 33605.3607
1315 E. SEVENTH AVENUE
AR
CH
IT
EC
TU
RE
, IN
C.
SUITE 106
DATE
AA26000655
PERMIT SET 1/16/17
ADDENDUM 01 02/15/17
DOOR TYPES
FINISH SCHEDULES &
A7.1
SCHEDULES AND FINIHSES
G1
DOOR TYPES
A1
FRAME TYPES
A4
WINDOW TYPES
C1
SIGNAGE
A12
3"=1'-0"
DOOR TRANSITION
E12
GLAZING SCHEDULE
G1
G2
CLEAR
TYPETAG REMARKS
1/4" THICK, TYP.
TEMPERED
BULLET RESISTANT
G3
TEMPERED
CLEAR
CLEAR
FIRELIGHT
OH 45 OR W-60
PLUS LAMINATED GLASS
DOOR TRANSITION
G12
DOOR TRANSITION
J12
DOOR TRANSITION
E14
John W
. T
hom
pson, A
IA
AR
9
12
71
1/1
6/1
7
1
1
1
13'-7" VERIFY
CASEWORK C06
E1
3/4" = 1'-0"
8" 1'-4"0 2'-8"
2'-6
"4
"
1'-1
0
1 2
"
6"
1
1 2
"
CASEWORK C01
A1
3/4" = 1'-0"
8" 1'-4"0 2'-8"
2'-6
"4
"
2'-4
1 2
"1
1 2
"
A8.2
A5
3'-9
1
2
" VERIFY
A8.2
A9
3'-9
1
2
" VERIFY
1'-9
"
4'-2
"
10'-7" VERIFY
CASEWORK C05
E7
3/4" = 1'-0"
8" 1'-4"0 2'-8"
2'-6
"4
"
1'-1
0
1 2
"
6"
1
1 2
"
A8.2
A9
4'-2
"
EQ EQEQ EQ EQ
2'-0"
A8.2
A1
CASEWORK C02
E12
3/4" = 1'-0"
2'-7" VERIFY
CASEWORK C04
J1
3/4" = 1'-0"
19'-2"
1
1 2
"
4"
3'-1
0"
KNEE SPACEKNEE SPACE
KNEE SPACE
A8.2
H1
A8.2
A12
CASEWORK C03
E13
3/4" = 1'-0"
6'-0" VERIFY
A8.2
A12
11'-0" VERIFY
A8.2
A12
90°
2'-0"2'-0"3'-4"11'-11" VERIFY
90°
2'-0" 2'-0" 3'-4"
CASEWORK C07
A5
3/4" = 1'-0"
8" 1'-4"0 2'-8"
4'-0"
A8.2
H1
3'-0
"
8"
1'-6
"1
'-6
"1
'-6
"1
'-6
"
6'-8
"
8"
1'-6
"1
'-6
"1
'-6
"1
'-6
"
6'-8
"
8
1 2
"
8"
10
"1
0"
2'-8"1'-2"
A8.2
H11
4"
KNEE SPACE
2'-8"1'-2"
KNEE SPACE
2'-8"1'-2"
KNEE SPACE
2'-8"1'-2"
KNEE SPACE
2'-8"1'-2"
3'-6
"
HIL
LS
BO
RO
UG
H C
OU
NT
Y S
HE
RIF
F'S
O
FF
IC
E
FIR
IN
G R
AN
GE
A
ND
W
OR
KO
UT
G
YM
PIN
EB
RO
OK
E B
US
IN
ES
S P
AR
K
HILLSBOROUGH COUNTY
SHERIFF'S OFFICE
2008 EAST 8TH AVENUE
TAMPA, FLORIDA 33605
1626-00
WIL
DE
R
PROJECT #:
DISTRIBUTION
TELEPHONE 813.242.6677
wilderarchitecture.com
FACSIMILE 813.242.6683
TAMPA, FLORIDA 33605.3607
1315 E. SEVENTH AVENUE
AR
CH
IT
EC
TU
RE
, IN
C.
SUITE 106
DATE
AA26000655
PERMIT SET 1/16/17
ADDENDUM 01 02/15/17
ELEVATIONS
CASEWORK
A8.1
PLASTIC LAMINATE
COUNTERTOP
PLASTIC LAMINATE
PANEL
PLASTIC LAMINATE
BACKSPLASH
PLASTIC LAMINATE
DRAWERS
SECURITY
DRAWER, E09
FIXED PLASTIC LAMINATE SHELVING,
1" THICK. PROVIDE 1X3" WD
SUPPORTS AT PERIMETER
FIXED PLASTIC LAMINATE SHELVING,
1" THICK. PROVIDE 1X3" WD
SUPPORTS AT PERIMETER
FIXED PLASTIC LAMINATE SHELVING,
1" THICK. PROVIDE 1X3" WD
SUPPORTS AT PERIMETER
FIXED PLASTIC LAMINATE
SHELVING, 1" THICK. PROVIDE 1X3"
WD SUPPORTS AT PERIMETER
SOLID SURFACE APRON
SOLID SURFACE COUNTERTOP
SOLID SURFACE BACKSPLASH
SOLID SURFACE APRON
SOLID SURFACE COUNTERTOP
SOLID SURFACE BACKSPLASH
SS COUNTERTOP
SS BACKSPLASH
SS COUNTERTOP
PROVIDE VERTICAL SUPPORTS AT FREE
ENDS OF SHELVING AND INTERMEDIATE
VERTICAL SUPPORTS AT SPANS OVER 4'-0"
John W
. T
hom
pson, A
IA
AR
9
12
71
1/1
6/1
7
PLASTIC LAMINATE DRAWERS,
LOCKABLE.
1
1
2'-6
"
1
1 2
"
2'-0"
4" 8"0 1'-4"
CASEWORK SECTION
A5
1 1/2" = 1'-0"
2'-6
"4
'-6
"
1
1 2
"
7'-0
"
2'-0"
4" 8"0 1'-4"
CASEWORK SECTION
A9
1 1/2" = 1'-0"
6"
4"
4"
4'-8
"
2'-6
"
1
1 2
"
2'-0"
4" 8"0 1'-4"
CASEWORK SECTION
A1
1 1/2" = 1'-0"
4"
6"
8
1 4
"
4" 8"0 1'-4"
CASEWORK SECTION
A12
1 1/2" = 1'-0"
8"
1'-6
"1
'-6
"1
'-6
"1
'-6
"
6'-8
"
1'-5"
2'-4" @ C03
3'-6
"
1
1 2
"
2'-0"
4"
4" 8"0 1'-4"
CASEWORK SECTION
H1
1 1/2" = 1'-0"
2'-0" @ C07
4" 8"0 1'-4"
CASEWORK SECTION
H4
1 1/2" = 1'-0"
2'-8
"
2
1 2
"1
1 2
"
3'-0
"
1"
3
4
"
2
1
2
" 7'-3
1
2
" 2
1
2
"
3
4
"
1"
8'-0"
4'-0
"
1
1 2
"
2'-0"
4"
4" 8"0 1'-4"
CASEWORK SECTION
H11
1 1/2" = 1'-0"
HIL
LS
BO
RO
UG
H C
OU
NT
Y S
HE
RIF
F'S
O
FF
IC
E
FIR
IN
G R
AN
GE
A
ND
W
OR
KO
UT
G
YM
PIN
EB
RO
OK
E B
US
IN
ES
S P
AR
K
HILLSBOROUGH COUNTY
SHERIFF'S OFFICE
2008 EAST 8TH AVENUE
TAMPA, FLORIDA 33605
1626-00
WIL
DE
R
PROJECT #:
DISTRIBUTION
TELEPHONE 813.242.6677
wilderarchitecture.com
FACSIMILE 813.242.6683
TAMPA, FLORIDA 33605.3607
1315 E. SEVENTH AVENUE
AR
CH
IT
EC
TU
RE
, IN
C.
SUITE 106
DATE
AA26000655
PERMIT SET 1/16/17
ADDENDUM 01 2/15/17
SECTIONS
CASEWORK
A8.2
SECURITY DRAWER (E09)
PLASTIC LAMINATE
COUNTERTOP
PLASTIC LAMINATE DRAWER
PLASTIC LAMINATE COUNTERTOP
GROMMET
PLASTIC LAMINATE
PANEL
SOLID SURFACE
COUNTERTOP
SOLID SURFACE
BACKSPLASH
ALUM FRAMED
MIRROR
SOLID SURFACE
APRON
FIXED PLASTIC
LAMINATE SHELVING,
1" THICK
1X3 PLASTIC LAMINATE
SUPPORT @ PERIMETER
SS COUNTERTOP
SS COUNTERTOP
1X3 PLASTIC LAMINATE
PERIMETER APRON
4X4 PLASTIC
LAMINATE TABLE LEG
John W
. T
hom
pson, A
IA
AR
9
12
71
1/1
6/1
7
1
1
1
SS BACKSPLASH
SS COUNTERTOP
SS BACKSPLASH
1
PLASTIC LAMINATE DRAWER, LOCKABLE