2
Approved Approved Arthurs Pass Visitors Centre Redevelopment 80 W Coast Rd, Arthur's Pass, 7875. Proposed Presentation/Zoning PLan KP Job 1801 Sheet No: Rev: Draft Developed Design Check all dimensions on site. Do not scale from plans. If in doubt consult architect. Read in conjunction with all consultants drawings. To Scale at A1, ½ Scale at A3 25/01/2018 Thursday, 25 January 2018 @ 12:33 p.m. N:\Data\1801 Arthurs Pass Visitors Centre\06 Drawings\20180112 Arthur Pass Visitors Centre DD Drawings.pln Katy 105 WIND ZONE: Very High EXPOSURE ZONE: B EQ ZONE: 4 - 67% All Dimensions to be checked on site. All drawings to be read in conjunction with JTB architectural specifications and drawings jerram + tocker + barron architects ltd 61 cambridge tce | po box 2013 | christchurch 8140 AUCKLAND | WELLINGTON | NELSON | CHRISTCHURCH t +64 3 366 9837 | [email protected] | www.jtbarchitects.co.nz HW 5,600 8,080 7,360 8,080 4,800 2,000 3,215 3,045 3,000 3,150 1 A09 1 A09 2 A09 2 A09 3 202 3 202 A A B B C C D D E E 1 1 2 2 3 3 5 5 7 7 6 6 4 4 C1 C2 EXHIBITION SPACE 1 EXHIBITION SPACE 2 RETAIL PROCESSING & LARGER STORAGE TBC SUBJECT TO COSTING STAFF ENTRY /BOOT ROOM EXHIBITION SPACE 3 FIRST EXPERIENCES INVITATIONAL VISITOR ENTRY/EXIT FIELD STAFF OFFICE/ OCCASIONAL FIRST AID ACC STAFF WC/SHOWER ACC WC UNISEX WC'S CLEANERS ROOM/ STORAGE SECURE STAFF OFFICE/CASH COUNTING STAFF ACCESS/ EGRESS FROM/TO CARPARK FROM/TO OVERFLOW CARPARK FROM/TO VILLAGE GET A COFFEE LEARN ABOUT HISTORIC JOURNEYS HEAD OFF FOR A WALK VOID OVERHEAD PROPOSED EXTENSION FOR VIEWS , LIGHT & WALKING ACESSS REVISED LANDSCAPING FOR CENTRAL ENTRY BIODIVERSITY GET INVOLVED CANTERBURY MUSEUM REQUIREMENTS FOR STAGECOACH AREA : - DISPLAY BARRIER , TYPE TBC - BLOCK OUT UV LIGHT - APPROPRIATE LUX LEVELS - IMPROVED MECHANICAL - HUMIDITY, TEMPERATURE ARCHIVES/STORAGE WC WC HALL BLACK OUT BLINDS KITCHEN WINDOW SEAT REVISED LANDSCAPING FOR CENTRAL ENTRY REVISED LANDSCAPING FOR NEW WINDOW LOOK AT IMPLICATIONS OF MOVING COACH (LOWERING FLOOR) - CONSIDER COST HOT DESKS COURIER DELIVERIES DOUBLE GLASS DOORS SKYLIGHT OVER SKYLIGHT OVER STORAGE TBC BY DESIGN LAB C1 24/7 ACCESS LOBBY TALL CABINET/ COLD STORAGE STAFF WORKSTATIONS WORKSTATION RECEPTION TBC BY DESIGN LAB SECURE DOORS BY APPOINTMENT ONLY SECURE DOORS SECURE DOORS SECURE DOOR PUBLIC DOOR VISITORS RESEARCH AREA / MEETING SPACE / OPEN PLAN LEARNING BACK LIT DISPLAY CASE & INFORMATION BOARDS VISIBLE FROM OUTSIDE 24 HR INFO/DISPLAY STORAGE HOT DESK SECURE DOOR COFFEE COUNTER STORAGE TBC BY DESIGN LAB ENTRY AREA GALLERY WINDOW STORAGE/MAIN D/B & TELCO LOCATION 1200MM APPROX. EXCLUSION ZONE VISUAL LINK SECURE DOOR STAFF AREA / KITCHEN STAFF QUIET SEATING/NOOK AREA SCREENING FOR WC PRIVACY & DEMARKATION STAFF DESK 750mm(h) LOWERED COUNTER 750mm(h) FOR ACCESSIBILITY RQMTS RETRACTABLE FOR ACCESS 900mm(h) COUNTER WITH KNEE SPACE FOR ALT ACCESSIBLE COUNTER HIGH COUNTER 1200mm(h) AND/OR RETAIL/DISPLAY UNIT TO PROVIDE WC ACCESS PRIVACY DESK 750mm(h) C1 C1 C1 SCREENING FOR WORKSTATION PRIVACY Proposed Ground Floor Zoning/Presentation Plan EXISTING AREA ZONING Exhibition Space 207m² (Not all usable with exisitng partitions) Reception/ Information Area 21m² Circulation/Entry Areas 58.6m² Public WC's 16m² Staff Areas 26m² Visitors/Research 21m² Public Amenities - Retail 16m² Storage 53m² PROPOSED AREA ZONING Exhibition Space 214m² Information/ Maps/Walks/ Experience Area 80m² Circulation/Entry Areas 31m² Public WC's 14m² Staff Areas 89m² Visitors/Research 27m² Storage 31.5m² Suggested movement/route
Transcript
Page 1: WIND ZONE: Very High EXPOSURE ZONE: B EQ ZONE: 4 - 67% · 2018. 5. 25. · Do not scale from plans. If in doubt consult architect. Read in conjunction with all consultants drawings.

ApprovedApprovedArthurs Pass Visitors Centre Redevelopment80 W Coast Rd, Arthur's Pass, 7875.Proposed Presentation/Zoning PLan

KP

Job 1801

Sheet No: Rev:

Draft Developed DesignCheck all dimensions on site.Do not scale from plans.If in doubt consult architect.Read in conjunction with all consultants drawings.

To Scale at A1, ½ Scale at A3 25/01/2018

Thurs

day,

25 Ja

nuary

2018

@ 12

:33 p.

m. N

:\Data

\1801

Arthu

rs Pa

ss Vis

itors

Centr

e\06 D

rawing

s\201

8011

2 Arth

ur Pa

ss Vi

sitors

Centr

e DD

Draw

ings.p

ln Ka

ty

105

WIND ZONE: Very HighEXPOSURE ZONE: BEQ ZONE: 4 - 67%All Dimensions to be checked on site.

All drawings to be read in conjunction withJTB architectural specifications and drawings

jerram + tocker + barron architects ltd61 cambridge tce | po box 2013 | christchurch 8140

AUCKLAND | WELLINGTON | NELSON | CHRISTCHURCHt +64 3 366 9837 | [email protected] | www.jtbarchitects.co.nz

HW

5,600 8,080 7,360 8,080

4,80

02,

000

3,21

53,

045

3,00

03,

150

1A09

1A09

2A09

2A09

3202

3202

A

A

B

B

C

C

D

D

E

E

1 1

2 2

3 3

5 5

7 7

6 6

4 4

C1 C2

EXHIBITIONSPACE 1

EXHIBITIONSPACE 2

RETAILPROCESSING

& LARGERSTORAGE

TBC SUBJECTTO COSTING

STAFF ENTRY/BOOTROOM

EXHIBITIONSPACE 3

FIRSTEXPERIENCESINVITATIONAL

VISITORENTRY/EXIT

FIELD STAFFOFFICE/

OCCASIONALFIRST AID

ACC STAFFWC/SHOWER

ACC WC

UNISEXWC'S

CLEANERSROOM/

STORAGE

SECURE STAFFOFFICE/CASH

COUNTING

STAFFACCESS/EGRESS

FROM/TOCARPARK

FROM/TOOVERFLOWCARPARK

FROM/TOVILLAGE

GET A COFFEE

LEARN ABOUTHISTORIC JOURNEYS

HEAD OFFFOR A WALK

VOIDOVERHEAD

PROPOSEDEXTENSIONFOR VIEWS,

LIGHT &WALKINGACESSS

REVISEDLANDSCAPING FOR

CENTRAL ENTRY

BIODIVERSITY GET INVOLVEDCANTERBURY MUSEUM REQUIREMENTSFOR STAGECOACH AREA:- DISPLAY BARRIER, TYPE TBC- BLOCK OUT UV LIGHT- APPROPRIATE LUX LEVELS- IMPROVED MECHANICAL - HUMIDITY,TEMPERATURE

ARCHIVES/STORAGE

WC WC

HALL

BLACK OUT BLINDS

KIT

CH

EN

WIN

DO

W S

EAT

REVISEDLANDSCAPING FOR

CENTRAL ENTRY

REVISEDLANDSCAPING

FOR NEWWINDOW

LOOK AT IMPLICATIONS OFMOVING COACH (LOWERINGFLOOR) - CONSIDER COST

HOTDESKS

COURIERDELIVERIES

DOUBLE GLASS DOORS

SKYLIGHTOVER

SKYLIGHTOVER

STORAGE TBC BY DESIGNLAB

C1

24/7ACCESSLOBBY

TALL

CA

BIN

ET/

CO

LDS

TOR

AG

E

STAFF WORKSTATIONS

WORKSTATION

RECEPTION TBC BYDESIGN LAB

SECUREDOORS BYAPPOINTMENTONLY

SECUREDOORS

SECUREDOORS

SECUREDOOR

PUBLICDOOR

VISITORSRESEARCH AREA/MEETING SPACE/

OPEN PLAN LEARNING

BACK LITDISPLAY CASE &

INFORMATIONBOARDS

VISIBLE FROMOUTSIDE 24 HRINFO/DISPLAY

STORAGE

HO

T D

ES

K

SECUREDOOR

CO

FFE

E C

OU

NTE

R

STORAGE TBC BY DESIGNLAB

ENTRYAREA

GALLERYWINDOW

STO

RA

GE

/MA

IN D

/B &

TEL

CO

LO

CAT

ION

1200

MM

AP

PR

OX.

EX

CLU

SIO

N Z

ON

E

VISUAL LINK

SECUREDOOR

STAFF AREA/KITCHEN

STAFF QUIET SEATING/NOOK AREA

SC

RE

EN

ING

FO

RW

C P

RIV

ACY

&D

EMAR

KATI

ON

STAFFDESK

750mm(h)

LOWERED COUNTER750mm(h) FOR

ACCESSIBILITY RQMTSRETRACTABLE FOR

ACCESS

900mm(h) COUNTER WITHKNEE SPACE FOR ALT

ACCESSIBLE COUNTER

HIG

H C

OU

NTE

R12

00m

m(h

)

AN

D/O

R R

ETAI

L/D

ISPL

AYU

NIT

TO

PR

OV

IDE

WC

AC

CE

SS

PR

IVA

CY

DESK750mm(h)

C1

C1C1

SC

RE

EN

ING

FO

RW

OR

KSTA

TIO

NPR

IVAC

Y

Proposed Ground Floor Zoning/Presentation Plan

EXISTING AREA ZONING

Exhibition Space207m²(Not all usable with exisitng partitions) Reception/ Information Area21m²

Circulation/Entry Areas58.6m²

Public WC's16m²

Staff Areas26m²

Visitors/Research21m²

Public Amenities - Retail16m²

Storage53m²

PROPOSED AREA ZONING

Exhibition Space 214m²

Information/ Maps/Walks/ Experience Area 80m²

Circulation/Entry Areas 31m²

Public WC's 14m²

Staff Areas 89m²

Visitors/Research 27m²

Storage 31.5m²

Suggested movement/route

Page 2: WIND ZONE: Very High EXPOSURE ZONE: B EQ ZONE: 4 - 67% · 2018. 5. 25. · Do not scale from plans. If in doubt consult architect. Read in conjunction with all consultants drawings.

ApprovedApprovedArthurs Pass Visitors Centre Redevelopment80 W Coast Rd, Arthur's Pass, 7875.Interior 3D Views

KP

Job 1801

Sheet No: Rev:

Draft Developed DesignCheck all dimensions on site.Do not scale from plans.If in doubt consult architect.Read in conjunction with all consultants drawings.

To Scale at A1, ½ Scale at A3 25/01/2018

Thurs

day,

25 Ja

nuary

2018

@ 12

:33 p.

m. N

:\Data

\1801

Arthu

rs Pa

ss Vis

itors

Centr

e\06 D

rawing

s\201

8011

2 Arth

ur Pa

ss Vi

sitors

Centr

e DD

Draw

ings.p

ln Ka

ty

502

WIND ZONE: Very HighEXPOSURE ZONE: BEQ ZONE: 4 - 67%All Dimensions to be checked on site.

All drawings to be read in conjunction withJTB architectural specifications and drawings

jerram + tocker + barron architects ltd61 cambridge tce | po box 2013 | christchurch 8140

AUCKLAND | WELLINGTON | NELSON | CHRISTCHURCHt +64 3 366 9837 | [email protected] | www.jtbarchitects.co.nz

Reception Area Coffee Doc/Reception View

Reception View 3 View Behind Reception Counter


Recommended