Introducing Wire Rope IsolatorsTypical Wire Rope Isolator ApplicationsTypical Wire Rope Isolator Applications
• Avionics• Carts, Transporters & Gurneys• Chemical Processing Equipment• Chimneys, Scrubbers & Vessels• Electronic Cabinets• Military Equipment• Navigation Equipment• Over-the-road Transport • Power Plant Piping Suspension• Pump, Generator & Compressor Isolation• Seismic Isolation• Shipboard Electronics• Shipping Cases, Skids & Containers• Transportable Shelters
Other Wire Rope Isolator Applications
CWR-coverNEW/RED 11/20/02 2:42 PM Page 3
Introducing Wire Rope IsolatorsEnidine Wire Rope IsolatorsEnidine Wire Rope Isolators
1Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Enidine, a preferred source for energy absorption and vibration isolation solutions, offers a full
range of Wire Rope and Compact Wire Rope Isolator products, each designed to reduce the harmful effectsof shock and vibration.
Wire Rope Isolators
Wire Rope Isolators are comprised of stainless steelstranded cable, threaded through aluminum alloyretaining bars, crimped and mounted for effectivevibration isolation. With their corrosion resistant, all-metal construction, Enidine Wire Rope Isolators are environmentally stable, high-performance shock and vibration isolators that are unaffected by temperature extremes, chemicals, oils, ozone and abrasives.
Featuring a patented crimping pattern, versatile mounting options and a variety of sizes, these helical isolator products can help ensure that your systems can effectively meet performance requirements in commercial, industrial, and defenseindustries, including MIL-STD-810, MIL-STD-167, MIL-S-901, MIL-E-5400, STANAG-042, BV43-44 and DEF-STND 0755. For more information, please refer to our “Wire Rope Isolator Selection Guide” on pages 2-3 to assist in selecting a model for your application.
Compact Wire Rope Isolators
For the best in vibration isolation capabilities, chooseEnidine’s Compact Wire Rope Isolators. Smaller than traditional wire ropes, these unique isolators provide cost-effective, simultaneous shock and vibration attenuation where package space is at a premium.
Enidine Compact Wire Rope Isolators feature an easy, single-point installation, which allows them to be installedin virtually any application. Their small size also permits the isolation of individual system components, makingthem ideal for use in sensitive equipment and electronics.Just as with our standard Enidine Wire Rope Isolators,Enidine Compact Wire Rope Isolators feature a patented, all-metal design and components that ensuremaximum reliability, regardless of temperature or substrate requirement, and that can help meet MILSPECSsimilar to those of our Wire Rope Isolator series. Please refer to our “Compact Wire Rope Isolator SelectionGuide” on pages 32-33 for more information.
If your application is outside the standard Compact Wire Rope Isolator product range, please consult thestandard Wire Rope Isolator portions of this catalog. If a standard solution is still not available, Enidine engineers can design an isolator to suit your specifications.
For further information on Enidine Wire Rope and Compact Wire Rope Isolator products, technical assistance and pricing, please contact Enidine or your nearest authorized distributor. A list of Enidine distributors can be found by visiting our website at www.enidine.com.
U.S. Patents 5,549,2856,290,2176,244,579
Load Axis Mounting Orientations
COMPRESSION
FIXED SHEAR(for Wire Rope Isolators)
FIXED ROLL
45˚COMPRESSION/ROLL
CWR-coverNEW/RED 11/20/02 2:42 PM Page 5
SIZING INSTRUCTIONS - SHOCK ISOLATIONSIZING INSTRUCTIONS - VIBRATION ISOLATIONSelecting appropriate isolators for shock is based on the Wire Rope Isolator’saverage stiffness at the required dynamic deflection (Dmin). Follow the stepsbelow to achieve a recommended Wire Rope Isolator selection.
STEP 1: Fill out Part I and Part III of the Application Worksheet.
STEP 2: Refer to the Load vs. Deflection curves for the desired loading orientation. Locate curves capable of the Minimum DynamicDeflection (Dmin) calculated from the worksheet. Find a curve that is on or slightly under the Average Force (Favg) at the AverageDeflection (davg) calculated from the worksheet.
STEP 3: Specify the required mounting option suffix to complete the partnumber. (Please refer to available mounting options as indicated on each Wire Rope Isolator series data page.)
If the desired system natural frequency is known, refer to the appropriate Load vs. Natural Frequency curves to determine the recommended Wire Rope Isolator model. If the preferred system natural frequency is unknown, follow the steps below to achieve a recommended Wire Rope Isolator selection.
STEP 1: Fill out Part I and Part II of the Application Worksheet.
STEP 2: Refer to the Load vs. Natural Frequency curves for the required loading orientation. Use the System Natural Frequency (ƒn ) calculated from the worksheet to select the smallest Wire Rope Isolator model capable of the static load (W).
STEP 3: Specify the required mounting option suffix to complete the partnumber. (Please refer to available mounting options as indicated on each Wire Rope Isolator series data page.)
Selecting An Enidine Wire Rope IsolatorSelecting An Enidine Wire Rope Isolator
2 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
PART I: SYSTEM DATA:
1. Total Load ( WT): WT = ________ lbs.
WT = ________ Kg x 9.81 = ________ N
2. Number of Isolators (n): n = ________
3. Static Load per Isolator (W): W = WT W = ________ lbs.* W = ________ N*
* Assumes a central CGn
4. Load Axis: Compression Load Axis Load AxisShear or Roll45º Compression/Roll ____________________ ___________________
PART II: VIBRATION SIZING:
1. Input Excitation Frequency (ƒi) = ________ Hz ( =rpm )
2. System Natural Frequency for 80% isolation: ƒn = ƒi
ƒn = ________ Hz* ƒn = ________ Hz*3.0
* The System Natural Frequency (ƒn ) must lie on a published curve.The published natural frequencies are based on a 1G input condition.Random Vibration inputs: Consult Enidine for recommendations.
PART III: SHOCK SIZING:1. Maximum Allowable Transmitted G Load: (GT): ________G’s2. Shock Input Velocity: (V) = ________ in./sec.2
________ m/sec.2
a) Free Fall Impact: g = 386 in./sec.2 or 9.81 m/sec.2
V = 2gh h = Drop Height (in. or m)
b) Half-Sine Acceleration Input:
V = 2 g
A0 = Peak Acceleration (G’s)
A0 t0
t0 = Duration (seconds)
π
3. Min. Response Deflection: Dmin = ________in. Dmin = ________mm
4. Average Force: Favg = ________lbs. Favg = ________N
5. Average Deflection: davg =Dmin davg = ________in. davg = ________mm
2
60
Fax, phone, or mail your order to the nearest Enidine/distributor location, Attention: Sales Department (see back cover for listing of Enidine locations).EXAMPLE:
20 WR8 – 600-08 – * – [ ]
1. Select Quantity 2. WR Series 3. Select Dash Number 4. Specify Mounting Option** 5. Select “M” For Metric Model
**Please refer to available mounting options as indicated on each WR series data page.
Ordering Information
If you have special requirements, send us your application and Enidine will contact you with recommendations for a solution.
APPLICATION WORKSHEET - INPUTS IMPERIAL/METRIC
Dmin =V
2
g (GT – 1)
Favg = W V2
2g Dmin
Dmin =V
2
g (GT – 1) 1000
Favg = W V2
2g (Dmin ) 1000
Specify Model Number
IMPERIAL METRIC
Imperial Metric
CWR-coverNEW/RED 11/20/02 2:42 PM Page 6
Selecting An Enidine Wire Rope IsolatorSelecting An Enidine Wire Rope IsolatorVIBRATION ISOLATION:
A 1,400-lb. pump is rotating at 1,725 rpm, transmitting vibration to adjoining equipment. To control the damaging effectsof unwanted vibration, the pump shall be isolated using four (4) isolators mounted in the compression load axis withimperial, flat head cap screws. The isolators shall be located symmetrically about the pump’s center of gravity.
Step 1: From Part I and Part II of the Application Worksheet.
Step 2: Referring to the Compression Load vs. Natural Frequency curves for an isolator capable of a maximum static load of 350 lbs., and a System Natural Frequency of approximately 9.6 Hz, yields a recommended isolator selection of WR16-206-06.
Step 3: From the Available Mounting Options column, verify that a “B” mounting style is available (for flat headcap screws in both mount bars). Adding the mounting option suffix to the model number gives the complete part number of WR16-206-06-B.
SHOCK ISOLATION:
Sensitive electronic equipment weighing 164 lbs. must withstand a 9-inch drop shock when packaged inside of its shipping container. The electronics shall be suspended inside of the container’s shell using eight (8) isolators (4 perside) in the roll loading axis. The equipment can withstand a maximum shock response of 15G’s. The isolators shall beinstalled symmetrically about the equipment’s center of gravity. Threaded metric holes is the desired mounting option.
Step 1: From Part I and Part III of the Application Worksheet.
Step 2: Referring to the Shear/Roll Load vs. Deflection curves for an isolator capable of a maximum deflection of1.29 inches or greater, and a curve point that is at or slightly below a force of 143 lbs. at .65 inches ofdeflection, yields a recommended isolator selection of WR12-506-06.
Step 3: From the Available Mounting Options column, verify that a “D” mounting style is available (for threadedholes in both mount bars). Adding the mounting option suffix to the model number, and metric designation(M) gives the complete part number of WR12-506-06-D-M.
3Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
WT = 1,400 lbs.Fi = 1,725 = 28.75 Hz
60
Fn = 2,875 = 9.6 Hz3
W = 1,400 = 350 lbs.4
V = √ 2(386)(9) = 83.4 inches per second
Dmin = 83.42= 1.29 inches
386(15 – 1)
Favg =(20.5)(83.4)2
= 143 lbs.2(386)(1.29)
davg = 1.29 = .65 inches2
Performance ConsiderationsThe following should be considered when selecting Enidine Wire Rope Isolator products:
Damping: • Typically 5-15%, depending on size and input level. For specific damping considerations, please consult Enidine.
Stabilizers: • Consider the use of stabilizers when the Height vs. Width ratio is greater than 2.
Natural Frequency Curve Basis: • Published natural frequency curves are based on a 1G input condition. Natural frequency shifts may result from various
input levels.
Severe Input Considerations: • Increase diameter of the wire rope cable.• Increase height of the Wire Rope Isolators.• Consult Enidine.
CWR-coverNEW/RED 11/20/02 2:42 PM Page 7
WR2-100-10-[ ] BM, DM, EM 18 25 0,02
WR2-200-10-[ ] S, AM, BM, CM, DM, EM 20 28 0,02
WR2-400-10-[ ] S, AM, BM, CM, DM, EM 25 30 0,03
WR2-600-10-[ ] S, AM, BM, CM, DM, EM 28 33 0,03
WR2-700-10-[ ] S, AM, BM, CM, DM, EM 30 36 0,03
WR2-800-10-[ ] S, AM, BM, CM, DM, EM 33 38 0,03
WR2-100-10-[ ] B, D, E 0.70 1.00 0.05
WR2-200-10-[ ] S, A, B, C, D, E 0.80 1.10 0.05
WR2-400-10-[ ] S, A, B, C, D, E 1.00 1.20 0.07
WR2-600-10-[ ] S, A, B, C, D, E 1.10 1.30 0.07
WR2-700-10-[ ] S, A, B, C, D, E 1.20 1.40 0.07
WR2-800-10-[ ] S, A, B, C, D, E 1.30 1.50 0.07
2.690 W
.16
.40 Ø.062
3.13
H
See Mounting Options
(68,3)
(4,1)
(10,2) (1,6)
(79,5)
WR2 SeriesWR2 Series
4 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
View Rotated 90º CW for clarityNote: Dimensions are in inches (mm).
MOUNTING HARDWARE
IMPERIAL METRIC#8-32 M4 (x 0,7)
82º COUNTERSINK 90º COUNTERSINK
MOUNTING OPTIONS
S A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole CountersunkHoleCountersunk
Hole
CountersunkHole
ThreadedThreaded
Threaded
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(lbs.)H(in.)
W(in.)
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(Kg)H(mm)
W(mm)
Maximum recommended torque forthreaded insert is 6 in.-lbs. (0,7 Nm)
U.S. Patent 5,549,285
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
CWR-coverNEW/RED 11/20/02 2:42 PM Page 8
WR2 SeriesWR2 Series
5Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
6
5
1
2
3
4
5
6
KEY1 WR2-100-102 WR2-200-103 WR2-400-104 WR2-600-105 WR2-700-106 WR2-800-10
KEY1 WR2-100-102 WR2-200-103 WR2-400-104 WR2-600-105 WR2-700-106 WR2-800-10
KEY1 WR2-100-102 WR2-200-103 WR2-400-104 WR2-600-105 WR2-700-106 WR2-800-10
1
2
3
4
5
6
CWR-coverNEW/RED 11/20/02 2:42 PM Page 9
WR3-100-10-[ ] BM, DM, EM 23 28 0,06
WR3-200-10-[ ] S, AM, BM, CM, DM, EM 25 30 0,07
WR3-400-10-[ ] S, AM, BM, CM, DM, EM 28 33 0,07
WR3-600-10-[ ] S, AM, BM, CM, DM, EM 33 38 0,07
WR3-700-10-[ ] S, AM, BM, CM, DM, EM 36 41 0,07
WR3-800-10-[ ] S, AM, BM, CM, DM, EM 38 43 0,08
WR3-100-10-[ ] B, D, E 0.90 1.10 0.14
WR3-200-10-[ ] S, A, B, C, D, E 1.00 1.20 0.15
WR3-400-10-[ ] S, A, B, C, D, E 1.10 1.30 0.15
WR3-600-10-[ ] S, A, B, C, D, E 1.30 1.50 0.15
WR3-700-10-[ ] S, A, B, C, D, E 1.40 1.60 0.16
WR3-800-10-[ ] S, A, B, C, D, E 1.50 1.70 0.18
3.950 W
.25
.50 Ø.094
4.42
H
See Mounting Options
(100,3)
(6,4)
(12,7) (2,4)
(112,3)
WR3 SeriesWR3 Series
6 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
View Rotated 90º CW for clarity
MOUNTING HARDWARE
IMPERIAL METRIC#10-32 M5 (x 0,8)
82º COUNTERSINK 90º COUNTERSINK
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(lbs.)H(in.)
W(in.)
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(Kg)H(mm)
W(mm)
Note: Dimensions are in inches (mm).
Maximum recommended torque forthreaded insert is 8 in.-lbs. (0,9 Nm)
MOUNTING OPTIONS
S A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole CountersunkHoleCountersunk
Hole
CountersunkHole
ThreadedThreaded
Threaded
U.S. Patent 5,549,285
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
CWR-coverNEW/RED 11/20/02 2:42 PM Page 10
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
WR3 SeriesWR3 Series
7Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
56
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
6
4
5
KEY1 WR3-100-102 WR3-200-103 WR3-400-104 WR3-600-105 WR3-700-106 WR3-800-10
KEY1 WR3-100-102 WR3-200-103 WR3-400-104 WR3-600-105 WR3-700-106 WR3-800-10
KEY1 WR3-100-102 WR3-200-103 WR3-400-104 WR3-600-105 WR3-700-106 WR3-800-10
CWR-coverNEW/RED 11/20/02 2:42 PM Page 11
WR4-100-10-[ ] BM, DM, EM 28 36 0,12
WR4-200-10-[ ] BM, DM, EM 30 38 0,12
WR4-400-10-[ ] S, AM, BM, CM, DM, EM 33 41 0,13
WR4-500-10-[ ] S, AM, BM, CM, DM, EM 36 43 0,13
WR4-600-10-[ ] S, AM, BM, CM, DM, EM 38 46 0,13
WR4-700-10-[ ] S, AM, BM, CM, DM, EM 41 48 0,14
WR4-800-10-[ ] S, AM, BM, CM, DM, EM 43 51 0,14
WR4-100-10-[ ] B, D, E 1.10 1.40 0.26
WR4-200-10-[ ] B, D, E 1.20 1.50 0.26
WR4-400-10-[ ] S, A, B, C, D, E 1.30 1.60 0.29
WR4-500-10-[ ] S, A, B, C, D, E 1.40 1.70 0.29
WR4-600-10-[ ] S, A, B, C, D, E 1.50 1.80 0.29
WR4-700-10-[ ] S, A, B, C, D, E 1.60 1.90 0.30
WR4-800-10-[ ] S, A, B, C, D, E 1.70 2.00 0.30
4.500 W
.31
.56 Ø.125
5.00
H
See Mounting Options
(114,3)
(7,9)
(14,2) (3,2)
(127,0)
WR4 SeriesWR4 Series
8 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
View Rotated 90º CW for clarity
MOUNTING HARDWARE
IMPERIAL METRIC1/4-20 M6 (x 1,0)
82º COUNTERSINK 90º COUNTERSINK
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(lbs.)H(in.)
W(in.)
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(Kg)H(mm)
W(mm)
Note: Dimensions are in inches (mm).
Maximum recommended torque forthreaded insert is 36 in.-lbs. (3,7 Nm)
MOUNTING OPTIONS
S A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole CountersunkHoleCountersunk
Hole
CountersunkHole
ThreadedThreaded
Threaded
U.S. Patent 5,549,285
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
CWR-coverNEW/RED 11/20/02 2:42 PM Page 12
WR4 SeriesWR4 Series
9Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
1
2
3
4
5
6
7
1
2
3
4
5
7
6
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
KEY1 WR4-100-102 WR4-200-103 WR4-400-104 WR4-500-105 WR4-600-106 WR4-700-107 WR4-800-10
KEY1 WR4-100-102 WR4-200-103 WR4-400-104 WR4-500-105 WR4-600-106 WR4-700-107 WR4-800-10
KEY1 WR4-100-102 WR4-200-103 WR4-400-104 WR4-500-105 WR4-600-106 WR4-700-107 WR4-800-10
CWR-coverNEW/RED 11/20/02 2:42 PM Page 13
WR5-200-10-[ ] BM, DM, EM 30 41 0,15
WR5-400-10-[ ] S, AM, BM, CM, DM, EM 33 43 0,15
WR5-600-10-[ ] S, AM, BM, CM, DM, EM 38 48 0,16
WR5-800-10-[ ] S, AM, BM, CM, DM, EM 46 53 0,17
WR5-900-10-[ ] S, AM, BM, CM, DM, EM 53 64 0,18
WR5-200-10-[ ] B, D, E 1.20 1.60 0.33
WR5-400-10-[ ] S, A, B, C, D, E 1.30 1.70 0.33
WR5-600-10-[ ] S, A, B, C, D, E 1.50 1.90 0.35
WR5-800-10-[ ] S, A, B, C, D, E 1.80 2.10 0.38
WR5-900-10-[ ] S, A, B, C, D, E 2.10 2.50 0.39
4.500
.56
5.00
See Mounting Options
(114,3)
(14,2)
W
.31
Ø.156 H
(7,9)
(4,0)
(127,0)
WR5 SeriesWR5 Series
10 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
View Rotated 90º CW for clarity
MOUNTING HARDWARE
IMPERIAL METRIC1/4-20 M6 (x 1,0)
82º COUNTERSINK 90º COUNTERSINK
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(lbs.)H(in.)
W(in.)
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(Kg)H(mm)
W(mm)
Note: Dimensions are in inches (mm).
Maximum recommended torque forthreaded insert is 38 in.-lbs. (4,3 Nm)
MOUNTING OPTIONS
S A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole CountersunkHoleCountersunk
Hole
CountersunkHole
ThreadedThreaded
Threaded
U.S. Patent 5,549,285
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
CWR-coverNEW/RED 11/20/02 2:42 PM Page 14
WR5 SeriesWR5 Series
11Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
KEY1 WR5-200-102 WR5-400-103 WR5-600-104 WR5-800-105 WR5-900-10
KEY1 WR5-200-102 WR5-400-103 WR5-600-104 WR5-800-105 WR5-900-10
KEY1 WR5-200-102 WR5-400-103 WR5-600-104 WR5-800-105 WR5-900-10
CWR-coverNEW/RED 11/20/02 2:42 PM Page 15
WR6-200-10-[ ] DM 30 36 0,19
WR6-300-10-[ ] DM 33 38 0,20
WR6-400-10-[ ] BM, DM, EM 36 41 0,21
WR6-500-10-[ ] S, AM, BM, CM, DM, EM 38 43 0,21
WR6-600-10-[ ] S, AM, BM, CM, DM, EM 41 46 0,22
WR6-700-10-[ ] S, AM, BM, CM, DM, EM 43 48 0,25
WR6-800-10-[ ] S, AM, BM, CM, DM, EM 51 58 0,26
WR6-850-10-[ ] S, AM, BM, CM, DM, EM 54 75 0,27
WR6-900-10-[ ] S, AM, BM, CM, DM, EM 62 88 0,28
WR6-950-10-[ ] S, AM, BM, CM, DM, EM 81 107 0,29
WR6-200-10-[ ] D 1.20 1.40 0.42
WR6-300-10-[ ] D 1.30 1.50 0.43
WR6-400-10-[ ] B, D, E 1.40 1.60 0.46
WR6-500-10-[ ] S, A, B, C, D, E 1.50 1.70 0.47
WR6-600-10-[ ] S, A, B, C, D, E 1.60 1.80 0.49
WR6-700-10-[ ] S, A, B, C, D, E 1.70 1.90 0.54
WR6-800-10-[ ] S, A, B, C, D, E 2.00 2.30 0.57
WR6-850-10-[ ] S, A, B, C, D, E 2.13 2.94 0.59
WR6-900-10-[ ] S, A, B, C, D, E 2.45 3.45 0.61
WR6-950-10-[ ] S, A, B, C, D, E 3.20 4.20 0.63
4.500
.56
See Mounting Options
(14,2)
W
.31
Ø.156 H
(7,9)
(4,0)
(127,0)
(114,3)
5.00
WR6 SeriesWR6 Series
12
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(lbs.)H(in.)
W(in.)
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(Kg)H(mm)
W(mm)
MOUNTING HARDWARE
IMPERIAL METRIC1/4-20 M6 (x 1,0)
82º COUNTERSINK 90º COUNTERSINK
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
View Rotated 90º CW for clarityNote: Dimensions are in inches (mm).
Maximum recommended torque forthreaded insert is 38 in.-lbs. (4,3 Nm)
MOUNTING OPTIONS
S A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole CountersunkHoleCountersunk
Hole
CountersunkHole
ThreadedThreaded
Threaded
U.S. Patent 5,549,285
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
CWR-coverNEW/RED 11/20/02 2:42 PM Page 16
13Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Load vs. Deflection Load vs. Natural Frequency
KEY1 WR6-200-102 WR6-300-103 WR6-400-104 WR6-500-105 WR6-600-106 WR6-700-107 WR6-800-108 WR6-850-109 WR6-900-10
10 WR6-950-10
WR6 SeriesWR6 Series
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
12
34
56
7
8
9
10
12
34
56
7
8
9
10
12
34
56
7
8
910
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
12
3
4
5
6
7
8
9
10
KEY1 WR6-200-102 WR6-300-103 WR6-400-104 WR6-500-105 WR6-600-106 WR6-700-107 WR6-800-108 WR6-850-109 WR6-900-10
10 WR6-950-10
KEY1 WR6-200-102 WR6-300-103 WR6-400-104 WR6-500-105 WR6-600-106 WR6-700-107 WR6-800-108 WR6-850-109 WR6-900-10
10 WR6-950-10
CWR-coverNEW/RED 11/20/02 2:42 PM Page 17
WR8-200-08-[ ] S, A, B, C, D, E 1.90 2.20 0.84
WR8-400-08-[ ] S, A, B, C, D, E 2.13 2.50 0.90
WR8-500-08-[ ] S, A, B, C, D, E 2.31 2.80 0.94
WR8-600-08-[ ] S, A, B, C, D, E 2.50 3.13 1.04
WR8-700-08-[ ] S, A, B, C, D, E 2.50 3.50 1.14
WR8-800-08-[ ] S, A, B, C, D, E 2.63 3.75 1.20
WR8-850-08-[ ] S, A, B, C, D, E 2.63 3.95 1.25
WR8-900-08-[ ] S, A, B, C, D, E 3.25 4.25 1.30
5.162
.63
.50
W
5.75
Ø.250 H
See Mounting Options
(131,1)
(16,0)
(12,7)
(146,1)
(6,4)
WR8 SeriesWR8 Series
14 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
View Rotated 90º CW for clarity
MOUNTING HARDWARE
IMPERIAL METRIC1/4-28 M6 (x 1,0)
82º COUNTERSINK 90º COUNTERSINK
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(lbs.)H(in.)
W(in.)
Imperial
Metric
WR8-200-08-[ ] S, AM, BM, CM, DM, EM 48 56 0,38
WR8-400-08-[ ] S, AM, BM, CM, DM, EM 54 64 0,41
WR8-500-08-[ ] S, AM, BM, CM, DM, EM 59 71 0,43
WR8-600-08-[ ] S, AM, BM, CM, DM, EM 64 80 0,47
WR8-700-08-[ ] S, AM, BM, CM, DM, EM 64 89 0,52
WR8-800-08-[ ] S, AM, BM, CM, DM, EM 67 95 0,54
WR8-850-08-[ ] S, AM, BM, CM, DM, EM 67 100 0,57
WR8-900-08-[ ] S, AM, BM, CM, DM, EM 83 108 0,59
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(Kg)H(mm)
W(mm)
Note: Dimensions are in inches (mm).
Maximum recommended torque forthreaded insert is 38 in.-lbs. (4,3 Nm)
MOUNTING OPTIONS
S A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole CountersunkHoleCountersunk
Hole
CountersunkHole
ThreadedThreaded
Threaded
U.S. Patent 5,549,285
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
CWR-coverNEW/RED 11/20/02 2:42 PM Page 18
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
WR8 SeriesWR8 Series
15Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
1
2
3
4
5
7
8
6
1
2
3
45
6
7
8
1
2
3
45
67
8
1
2
3
5
6
7
8
4
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
KEY1 WR8-200-082 WR8-400-083 WR8-500-084 WR8-600-085 WR8-700-086 WR8-800-087 WR8-850-088 WR8-900-08
KEY1 WR8-200-082 WR8-400-083 WR8-500-084 WR8-600-085 WR8-700-086 WR8-800-087 WR8-850-088 WR8-900-08
KEY1 WR8-200-082 WR8-400-083 WR8-500-084 WR8-600-085 WR8-700-086 WR8-800-087 WR8-850-088 WR8-900-08
CWR-coverNEW/RED 11/20/02 2:43 PM Page 19
WR12-206-06-[ ] SM, AM, BM, CM, DM, EM 71 84 0,83
WR12-306-06-[ ] SM, AM, BM, CM, DM, EM 74 89 0,85
WR12-406-06-[ ] SM, AM, BM, CM, DM, EM 76 105 0,90
WR12-506-06-[ ] SM, AM, BM, CM, DM, EM 83 108 0,95
WR12-606-06-[ ] SM, AM, BM, CM, DM, EM 89 108 0,98
WR12-706-06-[ ] SM, AM, BM, CM, DM, EM 105 121 1,07
WR12-806-06-[ ] SM, AM, BM, CM, DM, EM 108 140 1,13
WR12-206-06-[ ] S, A, B, C, D, E 2.80 3.31 1.82
WR12-306-06-[ ] S, A, B, C, D, E 2.90 3.50 1.88
WR12-406-06-[ ] S, A, B, C, D, E 3.00 4.13 1.99
WR12-506-06-[ ] S, A, B, C, D, E 3.25 4.25 2.09
WR12-606-06-[ ] S, A, B, C, D, E 3.50 4.25 2.15
WR12-706-06-[ ] S, A, B, C, D, E 4.13 4.75 2.36
WR12-806-06-[ ] S, A, B, C, D, E 4.25 5.50 2.48
4.375
6.66
1.00
6.125
1.750 W
HØ .375
.63
.27
See Mounting Options
(111,1)
(169,2)
(25,4)
(155,6)
(44,5)
(9,5)
(16,0)
(6,9)
WR12 SeriesWR12 Series
16
6 LOOP
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
View Rotated 90º CW for clarity
MOUNTING HARDWARE
IMPERIAL METRIC1/4-28 M6 (x 1,0)
82º COUNTERSINK 90º COUNTERSINK
MOUNTING OPTIONS
S(M) A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole CountersunkHoleCountersunk
Hole
CountersunkHole
ThreadedThreaded
Threaded
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(lbs.)H(in.)
W(in.)
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(Kg)H(mm)
W(mm)
Note: Dimensions are in inches (mm).
Maximum recommended torque forthreaded bar is 100 in.-lbs. (10 Nm)
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541Assembly Hardware (WR12 – WR40):
Alloy Steel, Zinc Plated
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
CWR-coverNEW/RED 11/20/02 2:43 PM Page 20
WR12 SeriesWR12 Series
17
6 LOOP
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
1
2
3
4
6
5
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
KEY1 WR12-206-062 WR12-306-063 WR12-406-064 WR12-506-065 WR12-606-066 WR12-706-067 WR12-806-06
KEY1 WR12-206-062 WR12-306-063 WR12-406-064 WR12-506-065 WR12-606-066 WR12-706-067 WR12-806-06
KEY1 WR12-206-062 WR12-306-063 WR12-406-064 WR12-506-065 WR12-606-066 WR12-706-067 WR12-806-06
CWR-coverNEW/RED 11/20/02 2:43 PM Page 21
WR12-200-08-[ ] SM, AM, BM, CM, DM, EM 71 84 1,10
WR12-300-08-[ ] SM, AM, BM, CM, DM, EM 74 89 1,13
WR12-400-08-[ ] SM, AM, BM, CM, DM, EM 76 105 1,20
WR12-500-08-[ ] SM, AM, BM, CM, DM, EM 83 108 1,26
WR12-600-08-[ ] SM, AM, BM, CM, DM, EM 89 108 1,30
WR12-700-08-[ ] SM, AM, BM, CM, DM, EM 105 121 1,43
WR12-800-08-[ ] SM, AM, BM, CM, DM, EM 108 140 1,50
WR12-200-08-[ ] S, A, B, C, D, E 2.80 3.31 2.43
WR12-300-08-[ ] S, A, B, C, D, E 2.90 3.50 2.50
WR12-400-08-[ ] S, A, B, C, D, E 3.00 4.13 2.65
WR12-500-08-[ ] S, A, B, C, D, E 3.25 4.25 2.78
WR12-600-08-[ ] S, A, B, C, D, E 3.50 4.25 2.87
WR12-700-08-[ ] S, A, B, C, D, E 4.13 4.75 3.15
WR12-800-08-[ ] S, A, B, C, D, E 4.25 5.50 3.31
See Mounting Options
4.375
8.50
1.00
6.125
1.7501.19 W
HØ .375
.63
(111,1)
(215,9)
(25,4)
(155,6)
(44,5)(30,2)
(9,5)
(16,0)
WR12 SeriesWR12 Series
18 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
View Rotated 90º CW for clarity
MOUNTING HARDWARE
IMPERIAL METRIC1/4-28 M8 (x 1,25)
82º COUNTERSINK 90º COUNTERSINK
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(lbs.)H(in.)
W(in.)
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(Kg)H(mm)
W(mm)
Note: Dimensions are in inches (mm).
MOUNTING OPTIONS
S(M) A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole CountersunkHoleCountersunk
Hole
CountersunkHole
ThreadedThreaded
Threaded
Maximum recommended torque forthreaded bar is 100 in.-lbs. (20 Nm)
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541Assembly Hardware (WR12 – WR40):
Alloy Steel, Zinc Plated
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
CWR-coverNEW/RED 11/20/02 2:43 PM Page 22
WR12 SeriesWR12 Series
19Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
1
2
3
4
5
6
7
12
3
4
5
6
7
12
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
KEY1 WR12-200-082 WR12-300-083 WR12-400-084 WR12-500-085 WR12-600-086 WR12-700-087 WR12-800-08
KEY1 WR12-200-082 WR12-300-083 WR12-400-084 WR12-500-085 WR12-600-086 WR12-700-087 WR12-800-08
KEY1 WR12-200-082 WR12-300-083 WR12-400-084 WR12-500-085 WR12-600-086 WR12-700-087 WR12-800-08
CWR-coverNEW/RED 11/20/02 2:43 PM Page 23
WR16-206-06-[ ] S, A, B, C, D, E 3.00 3.63 3.00
WR16-306-06-[ ] S, A, B, C, D, E 3.25 4.00 3.15
WR16-406-06-[ ] S, A, B, C, D, E 3.50 4.13 3.30
WR16-606-06-[ ] S, A, B, C, D, E 3.75 4.75 3.68
WR16-706-06-[ ] S, A, B, C, D, E 4.25 5.25 3.98
WR16-806-06-[ ] S, A, B, C, D, E 4.90 5.65 4.46
WR16-856-06-[ ] S, A, B, C, D, E 5.40 6.13 4.80
WR16-906-06-[ ] S, A, B, C, D, E 6.10 7.10 5.10
WR16-206-06-[ ] SM, AM, BM, CM, DM, EM 76 92 1,36
WR16-306-06-[ ] SM, AM, BM, CM, DM, EM 83 102 1,43
WR16-406-06-[ ] SM, AM, BM, CM, DM, EM 89 105 1,50
WR16-606-06-[ ] SM, AM, BM, CM, DM, EM 95 121 1,67
WR16-706-06-[ ] SM, AM, BM, CM, DM, EM 108 133 1,81
WR16-806-06-[ ] SM, AM, BM, CM, DM, EM 124 144 2,02
WR16-856-06-[ ] SM, AM, BM, CM, DM, EM 137 156 2,18
WR16-906-06-[ ] SM, AM, BM, CM, DM, EM 155 180 2,31
See Mounting Options
4.375
7.00
1.00
6.125
1.750
Ø .500
.75
W
H
.44
(111,1)
(177,8)
(25,4)
(11,2)
(155,6)
(44,5)
(12,7)
(19,1)
WR16 SeriesWR16 Series
20
6 LOOP
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
View Rotated 90º CW for clarity
MOUNTING HARDWARE
IMPERIAL METRIC1/4-28 (Threaded Only) M8 (x 1,25)5/16-24 (All Others) M8 (x 1,25)82º COUNTERSINK 90º COUNTERSINK
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(lbs.)H(in.)
W(in.)
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(Kg)H(mm)
W(mm)
MOUNTING OPTIONS
S(M) A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole CountersunkHoleCountersunk
Hole
CountersunkHole
ThreadedThreaded
Threaded
Note: Dimensions are in inches (mm).
Maximum recommended torque forthreaded bar is 115 in.-lbs. (20 Nm)
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541Assembly Hardware (WR12 – WR40):
Alloy Steel, Zinc Plated
Operating Temperature Range
-150ºF to 500ºF ( -100ºC to 260ºC )* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
CWR-coverNEW/RED 11/20/02 2:43 PM Page 24
WR16 SeriesWR16 Series
21
6 LOOP
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
23
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
KEY1 WR16-206-062 WR16-306-063 WR16-406-064 WR16-606-065 WR16-706-066 WR16-806-067 WR16-856-068 WR16-906-06
KEY1 WR16-206-062 WR16-306-063 WR16-406-064 WR16-606-065 WR16-706-066 WR16-806-067 WR16-856-068 WR16-906-06
KEY1 WR16-206-062 WR16-306-063 WR16-406-064 WR16-606-065 WR16-706-066 WR16-806-067 WR16-856-068 WR16-906-06
CWR-coverNEW/RED 11/20/02 2:43 PM Page 25
WR16-200-08-[ ] S, A, B, C, D, E 3.00 3.63 4.00
WR16-300-08-[ ] S, A, B, C, D, E 3.25 4.00 4.20
WR16-400-08-[ ] S, A, B, C, D, E 3.50 4.13 4.40
WR16-600-08-[ ] S, A, B, C, D, E 3.75 4.75 4.90
WR16-700-08-[ ] S, A, B, C, D, E 4.25 5.25 5.30
WR16-800-08-[ ] S, A, B, C, D, E 4.90 5.65 5.95
WR16-850-08-[ ] S, A, B, C, D, E 5.40 6.13 6.40
WR16-900-08-[ ] S, A, B, C, D, E 6.10 7.10 6.80
WR16-200-08-[ ] SM, AM, BM, CM, DM, EM 76 92 1,81
WR16-300-08-[ ] SM, AM, BM, CM, DM, EM 83 102 1,91
WR16-400-08-[ ] SM, AM, BM, CM, DM, EM 89 105 2,00
WR16-600-08-[ ] SM, AM, BM, CM, DM, EM 95 121 2,22
WR16-700-08-[ ] SM, AM, BM, CM, DM, EM 108 133 2,40
WR16-800-08-[ ] SM, AM, BM, CM, DM, EM 124 144 2,70
WR16-850-08-[ ] SM, AM, BM, CM, DM, EM 137 156 2,90
WR16-900-08-[ ] SM, AM, BM, CM, DM, EM 155 180 3,09
See Mounting Options
4.375
8.50
1.00
6.125
1.7501.19
Ø .500
.75
W
H
(111,1)
(215,9)
(25,4)
(155,6)
(44,5)(30,2)
(12,7)
(19,1)
WR16 SeriesWR16 Series
22 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
View Rotated 90º CW for clarity
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(lbs.)H(in.)
W(in.)
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(Kg)H(mm)
W(mm)
MOUNTING OPTIONS
S(M) A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole CountersunkHoleCountersunk
Hole
CountersunkHole
ThreadedThreaded
Threaded
Note: Dimensions are in inches (mm).
Maximum recommended torque forthreaded bar is 115 in.-lbs. (20 Nm)
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541Assembly Hardware (WR12 – WR40):
Alloy Steel, Zinc Plated
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
MOUNTING HARDWARE
IMPERIAL METRIC1/4-28 (Threaded Only) M8 (x 1,25)5/16-24 (All Others) M8 (x 1,25)82º COUNTERSINK 90º COUNTERSINK
CWR-coverNEW/RED 11/20/02 2:43 PM Page 26
WR16 SeriesWR16 Series
23Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
1
2
3
4
5
6
7
8
1
23
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
78
1
2
3
4
5
6
7
8
KEY1 WR16-200-082 WR16-300-083 WR16-400-084 WR16-600-085 WR16-700-086 WR16-800-087 WR16-850-088 WR16-900-08
KEY1 WR16-200-082 WR16-300-083 WR16-400-084 WR16-600-085 WR16-700-086 WR16-800-087 WR16-850-088 WR16-900-08
KEY1 WR16-200-082 WR16-300-083 WR16-400-084 WR16-600-085 WR16-700-086 WR16-800-087 WR16-850-088 WR16-900-08
CWR-coverNEW/RED 11/20/02 2:43 PM Page 27
WR20-200-08-[ ] CM, DM 89 102 3,00
WR20-300-08-[ ] S, AM, BM, CM, DM, EM 99 112 3,20
WR20-400-08-[ ] S, AM, BM, CM, DM, EM 102 121 3,40
WR20-600-08-[ ] S, AM, BM, CM, DM, EM 109 135 3,70
WR20-700-08-[ ] S, AM, BM, CM, DM, EM 119 152 4,00
WR20-800-08-[ ] S, AM, BM, CM, DM, EM 127 165 4,31
WR20-900-08-[ ] S, AM, BM, CM, DM, EM 135 178 4,63
WR20-200-08-[ ] C, D 3.50 4.00 6.62
WR20-300-08-[ ] S, A, B, C, D, E 3.90 4.40 7.06
WR20-400-08-[ ] S, A, B, C, D, E 4.00 4.75 7.50
WR20-600-08-[ ] S, A, B, C, D, E 4.30 5.31 8.16
WR20-700-08-[ ] S, A, B, C, D, E 4.70 6.00 8.83
WR20-800-08-[ ] S, A, B, C, D, E 5.00 6.50 9.50
WR20-900-08-[ ] S, A, B, C, D, E 5.30 7.00 10.20
WR20 SeriesWR20 Series
24
W
H
5.375
10.50
1.00 Ø .625
1.00
7.525
2.1501.49
See Mounting Options
(136,5)
(266,7)
(25,4) (15,9)
(25,4)
(191,1)
(54,6)(37,8)
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
View Rotated 90º CW for clarity
MOUNTING HARDWARE
IMPERIAL METRIC3/8-24 M10 (x 1,5)
82º COUNTERSINK 90º COUNTERSINK
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(lbs.)H(in.)
W(in.)
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(Kg)H(mm)
W)(mm)
MOUNTING OPTIONS
S A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole CountersunkHoleCountersunk
Hole
CountersunkHole
ThreadedThreaded
Threaded
Note: Dimensions are in inches (mm).
Maximum recommended torque forthreaded bar is 415 in.-lbs. (50 Nm)
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541Assembly Hardware (WR12 – WR40):
Alloy Steel, Zinc Plated
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
CWR-coverNEW/RED 11/20/02 2:43 PM Page 28
WR20 SeriesWR20 Series
25Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
1
23
4
5
6
7
1
23
4
5
6
7
12
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
KEY1 WR20-200-082 WR20-300-083 WR20-400-084 WR20-600-085 WR20-700-086 WR20-800-087 WR20-900-08
KEY1 WR20-200-082 WR20-300-083 WR20-400-084 WR20-600-085 WR20-700-086 WR20-800-087 WR20-900-08
KEY1 WR20-200-082 WR20-300-083 WR20-400-084 WR20-600-085 WR20-700-086 WR20-800-087 WR20-900-08
CWR-coverNEW/RED 11/20/02 2:43 PM Page 29
WR28-200-08-[ ] CM, DM 133 140 8,40
WR28-400-08-[ ] S, AM, BM, CM, DM, EM 152 165 9,53
WR28-600-08-[ ] S, AM, BM, CM, DM, EM 159 178 9,90
WR28-800-08-[ ] S, AM, BM, CM, DM, EM 191 210 11,50
WR28-900-08-[ ] S, AM, BM, CM, DM, EM 216 235 12,70
WR28-200-08-[ ] S, C, D 5.25 5.50 18.5
WR28-400-08-[ ] S, A, B, C, D, E 6.00 6.50 21.0
WR28-600-08-[ ] S, A, B, C, D, E 6.25 7.00 21.8
WR28-800-08-[ ] S, A, B, C, D, E 7.50 8.25 25.3
WR28-900-08-[ ] S, A, B, C, D, E 8.50 9.25 28.0
W
H
See Mounting Options
7.500
14.50
1.50 Ø .875
10.500
3.0002.00
1.50
(190,5)
(368,3)
(38,1) (22,2)
(38,1)
(266,7)
(76,2)(50,8)
WR28 SeriesWR28 Series
26 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
View Rotated 90º CW for clarity
MOUNTING HARDWARE
IMPERIAL METRIC1/2-13 M12 (x 1,75)
82º COUNTERSINK 90º COUNTERSINK
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(lbs.)H(in.)
W(in.)
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(Kg)H(mm)
W(mm)
MOUNTING OPTIONS
S A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole CountersunkHoleCountersunk
Hole
CountersunkHole
ThreadedThreaded
Threaded
Note: Dimensions are in inches (mm).
Maximum recommended torque forthreaded bar is 95 ft.-lbs. (100 Nm)
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541Assembly Hardware (WR12 – WR40):
Alloy Steel, Zinc Plated
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
CWR-coverNEW/RED 11/20/02 2:43 PM Page 30
WR28 SeriesWR28 Series
27Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
1
2
3
4
5
1
23
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
KEY1 WR28-200-082 WR28-400-083 WR28-600-084 WR28-800-085 WR28-900-08
KEY1 WR28-200-082 WR28-400-083 WR28-600-084 WR28-800-085 WR28-900-08
KEY1 WR28-200-082 WR28-400-083 WR28-600-084 WR28-800-085 WR28-900-08
CWR-coverNEW/RED 11/20/02 2:43 PM Page 31
WR36-200-08-[ ] S, AM, BM, CM, DM, EM 178 216 20,9
WR36-400-08-[ ] S, AM, BM, CM, DM, EM 216 241 24,0
WR36-600-08-[ ] S, AM, BM, CM, DM, EM 235 260 25,0
W
H
See Mounting Options
10.625
20.50
2.00 Ø 1.125
2.00
14.875
4.2502.81(269,9)
(520,7)
(50,8) (28,6)
(50,8)
(377,8)
(108,0)(71,4)
WR36 SeriesWR36 Series
28 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
View Rotated 90º CW for clarity
MOUNTING HARDWARE
IMPERIAL METRIC3/4-10 M18 (x 2,5)
82º COUNTERSINK 90º COUNTERSINK
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(lbs.)H(in.)
W(in.)
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(Kg)H(mm)
W(mm)
MOUNTING OPTIONS
S A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole CountersunkHoleCountersunk
Hole
CountersunkHole
ThreadedThreaded
Threaded
Note: Dimensions are in inches (mm).
Maximum recommended torque forthreaded bar is 300 ft.-lbs. (300 Nm)
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541Assembly Hardware (WR12 – WR40):
Alloy Steel, Zinc Plated
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
WR36-200-08-[ ] S, A, B, C, D, E 7.00 8.50 46
WR36-400-08-[ ] S, A, B, C, D, E 8.50 9.50 53
WR36-600-08-[ ] S, A, B, C, D, E 9.25 10.25 55
CWR-coverNEW/RED 11/20/02 2:43 PM Page 32
WR36 SeriesWR36 Series
29Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
1
2
3
1
2
3
1
2
31
2
3
1
2
3
1
2
3
KEY1 WR36-200-082 WR36-400-083 WR36-600-08
KEY1 WR36-200-082 WR36-400-083 WR36-600-08
KEY1 WR36-200-082 WR36-400-083 WR36-600-08
CWR-coverNEW/RED 11/20/02 2:43 PM Page 33
WR40-200-08-[ ] S, AM, BM, CM, DM, EM 178 210 24,0
WR40-400-08-[ ] S, AM, BM, CM, DM, EM 216 248 27,2
WR40-200-08-[ ] S, A, B, C, D, E 7.00 8.25 53
WR40-400-08-[ ] S, A, B, C, D, E 8.50 9.75 60
W
H
See Mounting Options
10.625
20.50
2.00 Ø 1.250
2.00
14.875
4.2502.81(269,9)
(520,7)
(50,8) (31,8)
(50,8)
(377,8)
(108,0)(71,4)
WR40 SeriesWR40 Series
30 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
View Rotated 90º CW for clarity
MOUNTING HARDWARE
IMPERIAL METRIC3/4-10 M18 (x 2,5)
82º COUNTERSINK 90º COUNTERSINK
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(lbs.)H(in.)
W(in.)
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(Kg)H(mm)
W(mm)
MOUNTING OPTIONS
S A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole CountersunkHoleCountersunk
Hole
CountersunkHole
ThreadedThreaded
Threaded
Note: Dimensions are in inches (mm).
Maximum recommended torque forthreaded bar is 300 ft.-lbs. (300 Nm)
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541Assembly Hardware (WR12 – WR40):
Alloy Steel, Zinc Plated
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
CWR-coverNEW/RED 11/20/02 2:43 PM Page 34
WR40 SeriesWR40 Series
31Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
1
2
2
1
2
1
1
2
1
2
1
2
KEY1 WR40-200-082 WR40-400-08
KEY1 WR40-200-082 WR40-400-08
KEY1 WR40-200-082 WR40-400-08
CWR-coverNEW/RED 11/20/02 2:43 PM Page 35
Selecting An Enidine Compact Wire Rope IsolatorSelecting An Enidine Compact Wire Rope Isolator
32 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
SIZING INSTRUCTIONS - SHOCK ISOLATIONSIZING INSTRUCTIONS - VIBRATION ISOLATIONSelecting appropriate isolators for shock is based on the Compact Wire RopeIsolator’s average stiffness at the required dynamic deflection (Dmin). Follow thesteps below to achieve a recommended Compact Wire Rope Isolator selection.
STEP 1: Fill out Part I and Part III of the Application Worksheet.
STEP 2: Refer to the Load vs. Deflection curves for the desired loading orientation. Locate curves capable of the Minimum DynamicDeflection (Dmin) calculated from the worksheet. Find a curve that is on or slightly under the Average Force (Favg) at the AverageDeflection (davg) calculated from the worksheet.
STEP 3: Specify the required mounting option suffix to complete the partnumber. (Please refer to available mounting options as indicated on each Compact Wire Rope Isolator series data page.)
If the desired system natural frequency is known, refer to the appropriate Loadvs. Natural Frequency curves to determine the recommended Compact WireRope Isolator model. If the preferred system natural frequency is unknown, follow the steps below to achieve a recommended Compact Wire Rope Isolatorselection.
STEP 1: Fill out Part I and Part II of the Application Worksheet.
STEP 2: Refer to the Load vs. Natural Frequency curves for the required loading orientation. Use the System Natural Frequency (ƒn ) calculated from the worksheet to select the smallest Compact Wire Rope Isolator model capable of the static load (W).
STEP 3: Specify the required mounting option suffix to complete the partnumber. (Please refer to available mounting options as indicated on each Compact Wire Rope Isolator series data page.)
Fax, phone, or mail your order to the nearest Enidine/distributor location, Attention: Sales Department (see back cover for listing of Enidine locations).EXAMPLE:
20 CR6 – 100 – * – [ ]
1. Select Quantity 2. CR Series 3. Select Dash Number 4. Specify Mounting Option** 5. Select “M” For Metric Model
**Please refer to available mounting options as indicated on each CR series data page.
Ordering Information
If you have special requirements, send us your application and Enidine will contact you with recommendations for a solution.
Specify Model Number
PART I: SYSTEM DATA:
1. Total Load ( WT): WT = ________ lbs.
WT = ________ Kg x 9.81 = ________ N
2. Number of Isolators (n): n = ________
3. Static Load per Isolator (W): W = WT W = ________ lbs.* W = ________ N*
* Assumes a central CGn
4. Load Axis: Compression Load Axis Load AxisShear or Roll45º Compression/Roll ____________________ ___________________
PART II: VIBRATION SIZING:
1. Input Excitation Frequency (ƒi) = ________ Hz ( =rpm )
2. System Natural Frequency for 80% isolation: ƒn = ƒi
ƒn = ________ Hz* ƒn = ________ Hz*3.0
* The System Natural Frequency (ƒn ) must lie on a published curve.The published natural frequencies are based on a 1G input condition.Random Vibration inputs: Consult Enidine for recommendations.
PART III: SHOCK SIZING:1. Maximum Allowable Transmitted G Load: (GT): ________G’s2. Shock Input Velocity: (V) = ________ in./sec.2
________ m/sec.2
a) Free Fall Impact: g = 386 in./sec.2 or 9.81 m/sec.2
V = 2gh h = Drop Height (in. or m)
b) Half-Sine Acceleration Input:
V = 2 g
A0 = Peak Acceleration (G’s)
A0 t0
t0 = Duration (seconds)
π
3. Min. Response Deflection: Dmin = ________in. Dmin = ________mm
4. Average Force: Favg = ________lbs. Favg = ________N
5. Average Deflection: davg =Dmin davg = ________in. davg = ________mm
2
60
Dmin =V
2
g (GT – 1)
Favg = W V2
2g Dmin
Dmin =V
2
g (GT – 1) 1000
Favg = W V2
2g (Dmin ) 1000
IMPERIAL METRICAPPLICATION WORKSHEET - INPUTS IMPERIAL/METRIC
Imperial Metric
CWR-coverNEW/RED 11/20/02 2:43 PM Page 36
VIBRATION ISOLATION:
A 6-lb. electronics box is failing due to a 40 Hz vibration input. Only .75 inches of space exists around the unit for an isolator. To control the damaging effects of vibration, the box shall be isolated using four (4) isolators mounted in thecompression load axis with imperial, socket head cap screws. The isolators shall be located symmetrically about thepump’s center of gravity.
Step 1: From Part I and Part II of the Application Worksheet.
Step 2: Determine which isolators match the desired height requirement. The CR1-100, CR2-200, and the CR3-100each have a height of .75 inches.
Step 3: Referring to the Compression Load vs. Natural Frequency curves for an isolator capable of a maximum static load of 1.5 lbs., and a System Natural Frequency of approximately 13.3 Hz, yields a recommended isolator of CR2-200.
Step 4: From the Available Mounting Options column, verify that a “D” mounting style is available (for threadedholes in both mount bars). Adding the mounting option suffix to the model number gives the complete partnumber of CR2-200-D.
SHOCK ISOLATION:
A 1.31-lb. computer hard drive is mounted inside a vehicle and must withstand a half-sine shock input of 30G’s, 5 in./sec.The hard drive shall be suspended inside of the vehicle using four (4) isolators (2 per side) in a roll loading axis withimperial, socket head cap screws. The hard drive can withstand a maximum shock response of 10G’s. The isolatorsshall be installed symmetrically about the equipment’s center of gravity.
Step 1: From Part I and Part III of the Application Worksheet.
Step 2: Referring to the Shear/Roll Load vs. Deflection curves for an isolator capable of a maximum deflection of .39 inches or greater, and a curve point that is at or slightly below a force of 1.49 lbs., at .195 inches of deflection, yields a recommended isolator selection of CR3-300.
Step 3: From the Available Mounting Options column, verify that a “D” mounting style is available (for threadedholes in both mount bars). Adding the mounting option suffix to the model number, gives the complete partnumber of CR3-300-D.
33Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
WT = 6 lbs. Fi = 40 Hz
Fn = 40 = 13.3 Hz3W =
6 = 1.50 lbs.
4
V =2 (386) (30)(.005) = 36.86 in./sec.
π
Dmin = 36.862= .39 inches
386 (10 – 1)
Favg = (.33)(36.86)2 = 1.49 lbs.
2(386)(.39)
davg = .39 = .195 inches2
Selecting An Enidine Compact Wire Rope IsolatorSelecting An Enidine Compact Wire Rope Isolator
Performance ConsiderationsThe following should be considered when selecting Enidine Wire Rope Isolator products:
Damping: • Typically 5-15%, depending on size and input level. For specific damping considerations, please consult Enidine.
Stabilizers: • Consider use of stabilizers when Height vs. Width ratio is greater than 2.
Natural Frequency Curve Basis: • Published natural frequency curves are based on a 1G input condition. Natural frequency shifts may result from various
input levels.
Severe Input Considerations: • Increase diameter of the wire rope cable.• Increase height of the Compact Wire Rope Isolators.• Consult Enidine.
CWR-coverNEW/RED 11/20/02 2:43 PM Page 37
CR1-100-[ ] S, A, B, C, D, E 0.66 0.73 0.11
CR1-200-[ ] S, A, B, C, D, E 0.75 0.79 0.11
CR1-300-[ ] S, A, B, C, D, E 0.90 0.91 0.12
CR1-400-[ ] S, A, B, C, D, E 1.04 1.03 0.12
CR1-100-[ ] S, AM, BM, CM, DM, EM 17 19 3,1
CR1-200-[ ] S, AM, BM, CM, DM, EM 19 20 3,1
CR1-300-[ ] S, AM, BM, CM, DM, EM 23 23 3,4
CR1-400-[ ] S, AM, BM, CM, DM, EM 26 26 3,4
CR1 SeriesCR1 Series
.16 (4,1) TYP
W
See Mounting Options
.32 (8,1)
.64 (16,3)
.38 (9,7)
.19 (4,8)
.44 (11,2)
.22 (5,6)
W H
34 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(oz.)H(in.)
W(in.)
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(g)H(mm)
W(mm)
MOUNTING HARDWARE
IMPERIAL METRIC#4-40 M3 (x 0,5)
82º COUNTERSINK 90º COUNTERSINK
Note: Dimensions are in inches (mm).
View Rotated 90º CW for clarity
MOUNTING OPTIONS
S A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole
CountersunkHole
Thru Hole
CountersunkHole
Threaded Threaded
Threaded Threaded
CountersunkHole
CountersunkHole
Maximum recommended torque forthreaded bar is 10 in.-lbs. (1,2 Nm)
U.S. Patent 6,290,217
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
CWR-coverNEW/RED 11/20/02 2:43 PM Page 38
CR1 SeriesCR1 Series
35Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
KEY1 CR1-1002 CR1-2003 CR1-3004 CR1-400
KEY1 CR1-1002 CR1-2003 CR1-3004 CR1-400
KEY1 CR1-1002 CR1-2003 CR1-3004 CR1-400
CWR-coverNEW/RED 2/5/03 5:10 PM Page 39
CR2-100-[ ] S, AM, BM, CM, DM, EM 16 20 3,7
CR2-200-[ ] S, AM, BM, CM, DM, EM 19 21 4,0
CR2-300-[ ] S, AM, BM, CM, DM, EM 23 24 4,3
CR2-400-[ ] S, AM, BM, CM, DM, EM 27 27 4,5
CR2-100-[ ] S, A, B, C, D, E 0.64 0.78 0.13
CR2-200-[ ] S, A, B, C, D, E 0.75 0.83 0.14
CR2-300-[ ] S, A, B, C, D, E 0.89 0.94 0.15
CR2-400-[ ] S, A, B, C, D, E 1.07 1.06 0.16
CR2 SeriesCR2 Series
36
.16 (4,1) TYP
W
See Mounting Options
.32 (8,1)
.64 (16,3)
.38 (9,7)
.19 (4,8)
.44 (11,2)
.22 (5,6)
W H
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(oz.)H(in.)
W(in.)
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(g)H(mm)
W(mm)
MOUNTING HARDWARE
IMPERIAL METRIC#4-40 M3 (x 0,5)
82º COUNTERSINK 90º COUNTERSINK
Note: Dimensions are in inches (mm).
View Rotated 90º CW for clarity
MOUNTING OPTIONS
S A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole
CountersunkHole
Thru Hole
CountersunkHole
Threaded Threaded
Threaded Threaded
CountersunkHole
CountersunkHole
Maximum recommended torque forthreaded bar is 10 in.-lbs. (1,2 Nm)
U.S. Patent 6,290,217
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
CWR-coverNEW/RED 11/20/02 2:43 PM Page 40
CR2 SeriesCR2 Series
37Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
KEY1 CR2-1002 CR2-2003 CR2-3004 CR2-400
KEY1 CR2-1002 CR2-2003 CR2-3004 CR2-400
KEY1 CR2-1002 CR2-2003 CR2-3004 CR2-400
CWR-coverNEW/RED 11/20/02 2:43 PM Page 41
CR3-100-[ ] S, AM, BM, CM, DM, EM 19 22 5,7
CR3-200-[ ] S, AM, BM, CM, DM, EM 23 24 6,2
CR3-300-[ ] S, AM, BM, CM, DM, EM 27 27 6,8
CR3-400-[ ] S, AM, BM, CM, DM, EM 33 30 7,4
CR3-100-[ ] S, A, B, C, D, E 0.75 0.88 0.20
CR3-200-[ ] S, A, B, C, D, E 0.90 0.95 0.22
CR3-300-[ ] S, A, B, C, D, E 1.06 1.06 0.24
CR3-400-[ ] S, A, B, C, D, E 1.28 1.20 0.26
CR3 SeriesCR3 Series
38
.19 (4,8) TYP
W
See Mounting Options
.39 (9,9)
.76 (19,3)
.38 (9,7)
.19 (4,8)
.50 (12,7)
.25 (6,4)
W H
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(oz.)H(in.)
W(in.)
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(g)H(mm)
W(mm)
MOUNTING HARDWARE
IMPERIAL METRIC#4-40 M3 (x 0,5)
82º COUNTERSINK 90º COUNTERSINK
Note: Dimensions are in inches (mm).
View Rotated 90º CW for clarity
MOUNTING OPTIONS
S A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole
CountersunkHole
Thru Hole
CountersunkHole
Threaded Threaded
Threaded Threaded
CountersunkHole
CountersunkHole
Maximum recommended torque forthreaded bar is 13 in.-lbs. (1,5 Nm)
U.S. Patent 6,290,217
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
CWR-coverNEW/RED 11/20/02 2:43 PM Page 42
CR3 SeriesCR3 Series
39Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
KEY1 CR3-1002 CR3-2003 CR3-3004 CR3-400
KEY1 CR3-1002 CR3-2003 CR3-3004 CR3-400
KEY1 CR3-1002 CR3-2003 CR3-3004 CR3-400
CWR-coverNEW/RED 11/20/02 2:43 PM Page 43
CR4-100-[ ] SM, AM, BM, CM, DM, EM 42 48 40
CR4-200-[ ] SM, AM, BM, CM, DM, EM 53 54 40
CR4-300-[ ] SM, AM, BM, CM, DM, EM 60 59 43
CR4-400-[ ] SM, AM, BM, CM, DM, EM 75 68 48
CR4-100-[ ] S, A, B, C, D, E 1.66 1.87 1.4
CR4-200-[ ] S, A, B, C, D, E 2.10 2.12 1.4
CR4-300-[ ] S, A, B, C, D, E 2.37 2.34 1.5
CR4-400-[ ] S, A, B, C, D, E 2.96 2.67 1.7
CR4 SeriesCR4 Series
40
W
W
1.00 (25,4)
1.34 (34,0)
.37 (9,4)
.20 (5,1)
See Mounting Options
H
1.10 (27,9)
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(oz.)H(in.)
W(in.)
DIMENSIONS UNIT WEIGHT (g)H
(mm)W
(mm)
View Rotated 90º CW for clarity
Notes: 1. Dimensions are in inches (mm).2. Top and Bottom Mount Bars are identical.
MOUNTING HARDWARE
IMPERIAL METRIC#10-32 M6 (x 1,0)
82º COUNTERSINK 90º COUNTERSINK
MOUNTING OPTIONS
S(M) A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole
CountersunkHole
Thru Hole CountersunkHole
Threaded
Threaded
Threaded
Threaded
CountersunkHole
CountersunkHole
Maximum recommended torque forthreaded bar is 40 in.-lbs. (7,5 Nm)
U.S. Patent 6,244,579
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
CWR-coverNEW/RED 11/20/02 2:43 PM Page 44
CR4 SeriesCR4 Series
41Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
KEY1 CR4-1002 CR4-2003 CR4-3004 CR4-400
KEY1 CR4-1002 CR4-2003 CR4-3004 CR4-400
KEY1 CR4-1002 CR4-2003 CR4-3004 CR4-400
CWR-coverNEW/RED 11/20/02 2:43 PM Page 45
CR5-100-[ ] SM, AM, BM, CM, DM, EM 41 48 45
CR5-200-[ ] SM, AM, BM, CM, DM, EM 53 54 48
CR5-300-[ ] SM, AM, BM, CM, DM, EM 60 59 51
CR5-400-[ ] SM, AM, BM, CM, DM, EM 76 67 57
CR5-100-[ ] S, A, B, C, D, E 1.60 1.89 1.6
CR5-200-[ ] S, A, B, C, D, E 2.09 2.13 1.7
CR5-300-[ ] S, A, B, C, D, E 2.36 2.32 1.8
CR5-400-[ ] S, A, B, C, D, E 2.99 2.64 2.0
CR5 SeriesCR5 Series
42
W
W
1.00 (25,4)
1.38 (35,1)
.39 (9,9)
.20 (5,1)
See Mounting Options
H
1.10 (27,9)
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(oz.)H(in.)
W(in.)
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(g)H(mm)
W(mm)
View Rotated 90º CW for clarity
Notes: 1. Dimensions are in inches (mm).2. Top and Bottom Mount Bars are identical.
MOUNTING HARDWARE
IMPERIAL METRIC#10-32 M6 (x 1,0)
82º COUNTERSINK 90º COUNTERSINK
MOUNTING OPTIONS
S(M) A(M) B(M)
C(M) D(M) E(M)
Thru Hole
Thru Hole
Thru Hole
CountersunkHole
Thru Hole CountersunkHole
Threaded
Threaded
Threaded
Threaded
CountersunkHole
CountersunkHole
Maximum recommended torque forthreaded bar is 40 in.-lbs. (7,5 Nm)
U.S. Patent 6,244,579
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
CWR-coverNEW/RED 11/20/02 2:43 PM Page 46
CR5 SeriesCR5 Series
43Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
KEY1 CR5-1002 CR5-2003 CR5-3004 CR5-400
KEY1 CR5-1002 CR5-2003 CR5-3004 CR5-400
KEY1 CR5-1002 CR5-2003 CR5-3004 CR5-400
CWR-coverNEW/RED 11/20/02 2:43 PM Page 47
CR6-100-[ ] SM, AM, BM, CM, DM, EM 47 54 57
CR6-200-[ ] SM, AM, BM, CM, DM, EM 55 59 62
CR6-300-[ ] SM, AM, BM, CM, DM, EM 64 64 65
CR6-400-[ ] SM, AM, BM, CM, DM, EM 79 73 74
CR6-100-[ ] S, A, B, C, D, E 1.83 2.11 2.0
CR6-200-[ ] S, A, B, C, D, E 2.15 2.31 2.2
CR6-300-[ ] S, A, B, C, D, E 2.51 2.50 2.3
CR6-400-[ ] S, A, B, C, D, E 3.09 2.86 2.6
CR6 SeriesCR6 Series
MOUNTING OPTIONS
S(M) A(M) B(M)
C(M) D(M) E(M)
44 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Thru Hole
Thru Hole
Thru Hole
CountersunkHole
Thru Hole CountersunkHole
Threaded
Threaded
Threaded
Threaded
CountersunkHole
CountersunkHole
W
W
1.00 (25,4)
1.41 (35,8)
.40 (10,2)
.20 (5,1)
See Mounting Options
H
1.10 (27,9)
MOUNTING HARDWARE
IMPERIAL METRIC#10-32 M6 (x 1,0)
82º COUNTERSINK 90º COUNTERSINK
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(oz.)H(in.)
W(in.)
Imperial
Metric
MODEL NO.SPECIFY
MOUNTINGOPTION [ ]
DIMENSIONSUNIT WEIGHT
(g)H(mm)
W(mm)
View Rotated 90º CW for clarity
Notes: 1. Dimensions are in inches (mm).2. Top and Bottom Mount Bars are identical.
Maximum recommended torque forthreaded bar is 40 in.-lbs. (7,5 Nm)
U.S. Patent 6,244,579
Operating Temperature Range-150ºF to 500ºF ( -100ºC to 260ºC )
Standard Materials & Finishes*Cable: Stranded 300 Series Stainless SteelRetaining Bars: Aluminum Alloy, treated per
MIL-C-5541
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
CWR-coverNEW/RED 11/20/02 2:43 PM Page 48
CR6 SeriesCR6 Series
45Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
Load vs. Deflection Load vs. Natural Frequency
Notes: A. Natural frequency curves based on 1G input.B. Do not extrapolate plotted curves.C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
KEY1 CR6-1002 CR6-2003 CR6-3004 CR6-400
KEY1 CR6-1002 CR6-2003 CR6-3004 CR6-400
KEY1 CR6-1002 CR6-2003 CR6-3004 CR6-400
CWR-coverNEW/RED 11/20/02 2:43 PM Page 49
SIZING INSTRUCTIONS - SHOCK ISOLATIONSIZING INSTRUCTIONS - VIBRATION ISOLATIONSelecting appropriate isolators for shock is based on the Wire Rope Isolator’saverage stiffness at the required dynamic deflection (Dmin). Follow the stepsbelow to achieve a recommended Wire Rope Isolator product selection.
STEP 1: Fill out Part I and Part III of the Application Worksheet.
STEP 2: Refer to the Load vs. Deflection curves for the desired loading orientation. Locate curves capable of the Minimum DynamicDeflection (Dmin) calculated from the worksheet. Find a curve that is on or slightly under the Average Force (Favg) at the AverageDeflection (davg) calculated from the worksheet.
STEP 3: Specify the required mounting option suffix to complete the partnumber. (Please refer to available mounting options as indicated on each Wire Rope and Compact Wire Rope Isolator series data page.)
If the desired system natural frequency is known, refer to the appropriate Loadvs. Natural Frequency curves to determine the recommended Wire Rope orCompact Wire Rope Isolator model. If the preferred system natural frequency isunknown, follow the steps below to achieve a recommended Wire Rope Isolatorproduct selection.
STEP 1: Fill out Part I and Part II of the Application Worksheet.
STEP 2: Refer to the Load vs. Natural Frequency curves for the required loading orientation. Use the System Natural Frequency (ƒn ) calculated from the worksheet to select the smallest Wire Rope Isolator model capable of the static load (W).
STEP 3: Specify the required mounting option suffix to complete the partnumber. (Please refer to available mounting options as indicated on each Wire Rope and Compact Wire Rope Isolator series data page.)
Application WorksheetApplication Worksheet
Fax, phone, or mail your order to the nearest Enidine/distributor location, Attention: Sales Department (see back cover for listing of Enidine locations).EXAMPLE:
20 WR8 or CR6 – 600-08 – * – [ ]
1. Select Quantity 2. WR or CR Series 3. Select Dash Number 4. Specify Mounting Option** 5. Select “M” For Metric Model
**Please refer to available mounting options as indicated on each WR and CR series data page.
Ordering Information
If you have special requirements, send us your application and Enidine will contact you with recommendations for a solution.
Specify Model Number
PART I: SYSTEM DATA:
1. Total Load ( WT): WT = ________ lbs.
WT = ________ Kg x 9.81 = ________ N
2. Number of Isolators (n): n = ________
3. Static Load per Isolator (W): W = WT W = ________ lbs.* W = ________ N*
* Assumes a central CGn
4. Load Axis: Compression Load Axis Load AxisShear or Roll45º Compression/Roll ____________________ ___________________
PART II: VIBRATION SIZING:
1. Input Excitation Frequency (ƒi) = ________ Hz ( =rpm )
2. System Natural Frequency for 80% isolation: ƒn = ƒi
ƒn = ________ Hz* ƒn = ________ Hz*3.0
* The System Natural Frequency (ƒn ) must lie on a published curve.The published natural frequencies are based on a 1G input condition.Random Vibration inputs: Consult Enidine for recommendations.
PART III: SHOCK SIZING:1. Maximum Allowable Transmitted G Load: (GT): ________G’s2. Shock Input Velocity: (V) = ________ in./sec.2
________ m/sec.2
a) Free Fall Impact: g = 386 in./sec.2 or 9.81 m/sec.2
V = 2gh h = Drop Height (in. or m)
b) Half-Sine Acceleration Input:
V = 2 g
A0 = Peak Acceleration (G’s)
A0 t0
t0 = Duration (seconds)
π
3. Min. Response Deflection: Dmin = ________in. Dmin = ________mm
4. Average Force: Favg = ________lbs. Favg = ________N
5. Average Deflection: davg =Dmin davg = ________in. davg = ________mm
2
60
Dmin =V
2
g (GT – 1)
Favg = W V2
2g Dmin
Dmin =V
2
g (GT – 1) 1000
Favg = W V2
2g (Dmin ) 1000
IMPERIAL METRICAPPLICATION WORKSHEET - INPUTS IMPERIAL/METRIC
Imperial Metric
46 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
CWR-coverNEW/RED 11/20/02 2:43 PM Page 50
Sketches/NotesSketches/Notes
47Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
CWR-coverNEW/RED 11/20/02 2:43 PM Page 51
Sketches/NotesSketches/Notes
48 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909
CWR-coverNEW/RED 11/20/02 2:43 PM Page 52
ComputerHardware
Laboratory Centrifuges
Medical Ventilators
CD-ROMDrives
U.S. Patents 6,290,2176,244,579
Typical Compact Wire Rope Isolator ApplicationsTypical Compact Wire Rope Isolator Applications
• Audio/Visual Equipment• Avionics• Catering Carts• Communications Packages• Medical Devices• Sensitive Electronic Equipment
Other Compact Wire Rope IsolatorApplications
CWR-coverNEW/RED 11/20/02 2:42 PM Page 4
Solutions in Energy Absorption and Vibration Isolation.
Enidine Incorporated7 Centre DriveOrchard Park, New York 14127 • USAPhone: 716-662-1900Fax: 716-662-1909www.enidine.com
Subsidiaries and Affiliates:
Enidine West184 Technology Dr., Suite 201Irvine, California 92618 • USAPhone: 949-727-9112Fax: 949-727-9107www.enidine.com
Enidine GmbHRheinauenstr, 579415 Bad BellingenRheinweiler • GermanyPhone: 49 7635 8101 0Fax: 49 7635 8101 99www.enidine.de
Enidine Co. Ltd.398, Chigasaki-Cho, Tsuzuki-KuYokohama-Shi, Kanagawa 224-0031JapanPhone: 81 45 947 1671Fax: 81 45 945 3967www.enidine.co.jp
Enidine Corporativo De Mexico, S.A. de C.V.Av. Patria 3124-ACol El SauzGuadalajara, CP Jalisco • Mexico 45080Phone: 52 3 646-8100Fax: 52 3 646-6755www.enidine.com.mx
Enidine U.K. Ltd.Patrick Gregory RoadWolverhampton West Midlands, WV11 3DZUnited KingdomPhone: 44 1902 304000Fax: 44 1902 305676www.enidine.co.uk
ENIDINE PRODUCTSShock Absorbers • Rate Controls • Air Springs • One-Shot Emergency Stops
Elastomeric Isolators • Wire Rope Isolators • Compact Wire Rope Isolators • Heavy Industry BuffersUltraLOC™ Seat Recline Controls • Stow Bin Actuators/Rate Controls • Interior Noise Isolators
Energy Absorption Devices • Rotary Actuators/Dampers • APU Isolators
CGWRICMB 11/02 10M
CWR-coverNEW/RED 11/20/02 2:41 PM Page 1