4
Wireless Thermal Monitoring Solutions for Low and Medium Voltage Switchgear Effectively Monitor the Temperature of your Switchgear for Long Term, Cost-Effective Reliability and Safety Temperature sensors installed in equipment interface with monitoring units to remotely report overheating for proactive planning and mini- mize downtime. Designed for continuous monitoring of ambient bus and power con- nections through measurement of wireless temperature sensors that require NO power or wiring. User-configurable alarms, both limit and differential via optional HMI monitoring system. Industry standard Modbus RTU communications to customer SCADA Why Measure Temperature? Overview Bus joints and power connections are subject to overheating due to overload, corrosion, loose connections and environmental conditions Increase in heat will intensify until complete thermal failure of the con- nection or nearby insulation Next generation continuous Thermal Monitoring in lieu of traditional IR windows and periodic thermal imaging.
Transcript
Page 1: Wireless Thermal Monitoring Solutions for Low and Medium ... · Wireless Thermal Monitoring Solutions for Low and Medium Voltage Switchgear Effectively Monitor the Temperature of

Wireless Thermal Monitoring Solutions for Low and Medium Voltage Switchgear

Effectively Monitor the Temperature of your Switchgear for Long Term, Cost-Effective Reliability and Safety

• Temperature sensors installed in equipment interface with monitoring units to remotely report overheating for proactive planning and mini-mize downtime.

• Designed for continuous monitoring of ambient bus and power con-nections through measurement of wireless temperature sensors that require NO power or wiring.

• User-configurable alarms, both limit and differential via optional HMI monitoring system.

• Industry standard Modbus RTU communications to customer SCADA

Why Measure Temperature?

Overview

• Bus joints and power connections are subject to overheating due to overload, corrosion, loose connections and environmental conditions

• Increase in heat will intensify until complete thermal failure of the con-nection or nearby insulation

• Next generation continuous Thermal Monitoring in lieu of traditional IR windows and periodic thermal imaging.

Page 2: Wireless Thermal Monitoring Solutions for Low and Medium ... · Wireless Thermal Monitoring Solutions for Low and Medium Voltage Switchgear Effectively Monitor the Temperature of

Safety: Directly mounted wireless sensors to critical measuring points while ensuring all safety requirements are maintained.

No Maintenance: 20+ year life expectancy

Easy Installation: Sensors do not require “line of sight” and can be mounted under insulation boots or tape

Reliability: Sensors designed to withstand harsh envi-ronments

Section 1 Section 2

Wireless Thermal Monitoring Solutions

How it WorksTemperature sensors are powered by RF signals through the Thermal Monitoring Module and antenna Temperature Interface Module.

The Thermal Monitoring Module provides the measurements taken from the sensors and immediately makes available the data through industry standard communication protocols for critical equipment monitoring.

Temperature Measurement Methods

Periodic, 1 or 2 times per year

Unable to measure under boots and locate all bus joints and connections

Requires engineering personnel

Dangerous if measuring with live energization of switchgear requiring high level PPE

Traditional Approach The IEM Approach

RS485 RS485

Thermal Monitoring Module

Thermal Monitoring Module

Temperature Interface Module

Temperature Sensor ( up to 12)

Temperature Interface Module

Temperature Sensor ( up to 12)

• Partial Discharge Sensor / Interface Module

• Humidity Sensors

• MB RTU to TCP/IP Gateway

Options • Thermal Monitoring Software

• 17” HMI/Panel PC

Page 3: Wireless Thermal Monitoring Solutions for Low and Medium ... · Wireless Thermal Monitoring Solutions for Low and Medium Voltage Switchgear Effectively Monitor the Temperature of

Low Voltage Example:

Medium Voltage Example:

Wireless Thermal Monitoring Solutions

Installation Overview

5kV - 38kV Metal-clad / Metal-enclosed and custom assemblies

Up to 600V

Wireless Temperature Sensors (3x)

Wireless Temperature Sensors (3x)

Low Voltage Compartment

Main Bus Comparment

BreakerComparment

CableComparment

Temp Interface Module

Thermal MonitoringModule

Wireless Temperature Sensors (3x)

Wireless Temperature Sensors (3x)

Thermal Monitoring Module

Breaker Compartment

Temp Interface Module

Wireless Temperature Sensors (3x)

Wireless Temperature Sensors (3x)

Cable Compartment

Low Voltage Compartment

Bus Compartment

Page 4: Wireless Thermal Monitoring Solutions for Low and Medium ... · Wireless Thermal Monitoring Solutions for Low and Medium Voltage Switchgear Effectively Monitor the Temperature of

Profitability

Reliability

Safety

• Lower maintenance costs

• Minimize downtime

• Extend bus life

• Increased ROI

• Optimize bus performance

• Quick identification of issues

• Proactive planning

• Avoid downtime

• Predict potential problem areas

• Prevent catastrophic failure

• Improve response time

• Monitor areas with limited access

• Keep personnel and facility safe

Benefits of Utilizing Wireless Thermal Monitoring

©2015 The New IEM LLC. Industrial Electric Mfg.™ and IEM Power Systems™ are trademarks of The New IEM LLC. in the U.S. and other countries. All rights reserved. Thermal Monitoring.v1

Corporate Headquarters

Industrial Electric Mfg. 48205 Warm Springs Blvd Fremont CA 94539 USA

dir: +1.510.656.1600

www.iemfg.com

Jacksonville

IEM Power Systems 11902 Central Parkway Jacksonville FL 32224 USA

dir: +1.904.365.4444

www.iemps.com

Vancouver

Industrial Electric Mfg. 201 - 27353 58th Crescent Langley BC V4W 3W7 CANADA

dir: +1.866.302.9836

www.iemfg.com


Recommended