up SITTING ROOM UTILITY KITCHEN/ DINING ROOM CONSERVATORY W/C STORE COAL STORE LOBBY HALLWAY PORCH ramp up up up up MASTER BEDROOM LANDING BEDROOM 2 BEDROOM 3 BATHROOM Rev Date Notes NOTES: Do not scale from this drawing except for planning application purposes. PROJECT: DRAWING TITLE: SCALE: DATE: DRAWN: DWG NO. REV. Initials Proposed extension & alterations to- Existing Floor Plans, Elevations, 1:50 1:100 Site & Site Location Plans. The Contractor is to check and verify all building and site dimensions, levels and sewer invert levels at connection points before work starts. The Contractor is to comply in all respects with current Building Legislation, British Standard Specifications, Building Regulations, Construction (Design & Management) Regulations, Party Wall Act, etc. whether or not specifically stated on this drawing. This drawing must be read with and checked against any structural, geotechnical or other specialist documentation provided. This drawing is not intended to show details of foundations, ground conditions or ground contaminants. Each area of ground relied upon to support any structure depicted (including drainage) must be investigated by the Contractor. A suitable method of foundation should be provided allowing for existing ground conditions. Any suspect or fluid ground, contaminates on or within the ground, should be further investigated by a suitable expert. Any earthwork constructions shown indicate typical slopes for guidance only & should be further investigated by a suitable expert. Where existing trees are to be retained they should be subject to a full Arboricultural inspection for safety. All trees are to be planted so as to ensure they are a minimum of 5 metres from buildings and 3 metres from drainage and services. A suitable method of foundation is to be provided to accommodate the proposed tree planting. Sketch proposals are for illustrative purposes only & as such are subject to detailed site investigation including ground conditions/contaminants, drainage, design & planning/density negotiations. Sketch proposals may be based upon enlargements of OS sheets & visual estimations of existing site features, accuracy will therefore need to be verified by survey. Sketch proposals have not been considered in respect of CDM Regulations. 4 H O L L Y B U S H R O A D , N E W B O R O U G H BUILDING REGULATIONS SITE PLAN SCALE 1:500 SITE LOCATION PLAN SCALE 1:1250 1:500 1:1250 at A1 C COPYRIGHT NICHE ARCHITECTURE LTD SIDE ELEVATION REAR ELEVATION FRONT ELEVATION GROUND FLOOR PLAN FIRST FLOOR PLAN SECOND FLOOR PLAN Ach Staffordshire, DE13 8SF 4 Hollybush Road 16-014-WD-101 29.04.16 Newborough
Transcript
Page 1: Working Drawing Hollybush[1]

up

SITTING ROOM

UTILITYKITCHEN/

DINING ROOM

CONSERVATORY

W/C

STORE COALSTORE

LOBBY

HALLWAY

PORCH

ramp

upup

up

up

MASTER

BEDROOM

LANDING

BEDROOM 2

BEDROOM 3

BATHROOM

RevDate

Notes

NOTES:Do not scale from this drawing except for planningapplication purposes.

PROJECT:

DRAWING TITLE:

SCALE:DATE: DRAW

N:

DWG NO.

REV. Initials

Proposed extension & alterations to-

Existing Floor Plans, Elevations,

1:50 1:100

Site & Site Location Plans.

The Contractor is to check and verify all building and site dimensions,levels and sewer invert levels at connection points before work starts.The Contractor is to comply in all respects with current BuildingLegislation, British Standard Specifications, Building Regulations,Construction (Design & Management) Regulations, Party W

all Act, etc.whether or not specifically stated on this drawing. This drawing mustbe read with and checked against any structural, geotechnical or otherspecialist documentation provided.

This drawing is not intended to show details of foundations, groundconditions or ground contaminants. Each area of ground relied upon tosupport any structure depicted (including drainage) must be investigatedby the Contractor. A suitable method of foundation should be providedallowing for existing ground conditions. Any suspect or fluid ground,contaminates on or within the ground, should be further investigatedby a suitable expert. Any earthwork constructions shown indicate typicalslopes for guidance only & should be further investigated by a suitableexpert.

Where existing trees are to be retained they should be subject to a full

Arboricultural inspection for safety. All trees are to be planted so as toensure they are a minimum of 5 metres from buildings and 3 metres fromdrainage and services. A suitable method of foundation is to be providedto accommodate the proposed tree planting.

Sketch proposals are for illustrative purposes only & as such aresubject to detailed site investigation including groundconditions/contaminants, drainage, design & planning/densitynegotiations. Sketch proposals may be based upon enlargements ofOS sheets & visual estimations of existing site features, accuracywill therefore need to be verified by survey. Sketch proposals have notbeen considered in respect of CDM Regulations.

4 H O L L Y B U S H R O A D , N E W B O R O U G H

BUILDING REGULATIONS

SITE PLANSCALE 1:500

SITE LOCATION PLANSCALE 1:1250

1:500 1:1250 at A1

C COPYRIGHT NICHE ARCHITECTURE LTD

SIDE ELEVATIONREAR ELEVATION

FRONT ELEVATION

GROUND FLOOR PLANFIRST FLOOR PLAN

SECOND FLOOR PLANAch

Staffordshire, DE13 8SF

4 Hollybush Road

16-014-WD-101

29.04.16

Newborough

Page 2: Working Drawing Hollybush[1]

SITTING ROOM

UTILITY

HALLWAY

up

BOOTS

SHOWER ROOM

STORE

STUDY/ PLAYROOM

KITCHEN

DINING

FAMILY

w/mt/d

f/f

void

ROOFLIGHTROOFLIGHT

up

STEEL TO STRUCTURAL ENGINEER'S DETAILSTEEL TO STRUCTURAL ENGINEER'S DETAIL

W1

D1

W2

D2

D3D4

New Openingformed asshown.

New Openingformed asshown.

DCSFG

SFG

SFG

SFG

RWP

Walls to be

demolishedshown dashed

Walls to be

demolishedshown dashed

Walls to be

demolishedshown dashed

Foundation shown dashed.

Foundation shown dashed.

ICSVP

Lintel aboveLintel above

RWP

RWP

RWP

IC

IC

IC IC

Sink drainageconnected toexisting kitchendrainage

IC

To existingdrainage

NOTE:-ALL DRAW

INGS TO BEREAD IN CONJUNCTIONW

ITH STRUCTURALENGINEERS DRAW

INGS &CALCULATIONS.

NOTE:-CONTRACTOR TO CHECK ALL DIM

ENSIONS ON SITE.

DRAINAGE INDICATIVE ONLY - TO BE DETERMINDED

ON THE SITE BY THE CONTRACTOR.

300415

985

9938325

30001085

24933000

75

10563

3002779751496 2526752313

3850

300

9939

5094 995

3002415

2715

3004193

17701362

4493

1362

450

4

3 3

22

22

2

2

BTTV

BT

SD

FD30

FD30

FD30

TR

Keep electricsand heating asexisting

182875

2265

1928

851

875

131575

2803

2313 75 1496 75 2526 75 2779

588

1895

8254645

415

165 850 3760 850 1299

B

A

SFS

SFS

SFS

SFS

SFS

Electric layoutindicative only -refer tospecialistkitchen design.

B

Assumed joist span. TBC bystructural engineer.

Assumed joist span. TBC bystructural engineer.

Assumed looserafter span. TBC bystructural engineer.

Underfloor heating tosingle storey rearextension.

EXTRACT

A

Log burner installedin stict accordancewith manufacturersinstructions.

RF1RF2

HEARTH

SCAV

STOVECOM

BUSTIBLEAIR VENTPIPE

SVP

C C

D1W

1W

2

W3

to match existing

1350

to match existing to match existing

1200

to match existing

RF7

Code 4 flashing to all abutments.

OBSCURE

D2

2100

2220DPC TO

US SOFFIT

to match

existing

to matchexisting

Code 4 flashing toall abutments.

SVPRW

PRW

PRW

P

D4D3 W

4

2100 1200

to match existing

to match existing

2100

2220 DPC TO

US SOFFIT

RF4RF5

RF6RF3

RF1RF2

Code 4 flashing to all abutments.

2220DPC TO USOF SOFFIT

to matchexisting

BEDROOM 5

LANDING

BEDROOM 2

BEDROOM 3

BATHROOM

ENSUITE

W.

W.

W.

W.

W.

void

dnup

BEDROOM 4

New Openingformed asshown.

SVP

RWP

W3

W4

New Openingformed asshown.

Walls to be

demolishedshown dashed

SVP

RF1780X980

RF2780X980

Lintel above

New trimmer

New trimmer

RWP

RWP

7224

300300 3223753327

4193300

4493

13621770

1362

4193300

13621770

1362

4493

1085780

1440780

6478

Keep electricsand heating asexisting

Keep electricsand heating asexisting

2

4

4

4

3

SDFD

30

FD30

FD30

FD30

TR

101375

3106

310675

1013

1425 75 1723756002727

128 850 2954 882 1810

1440 75

A

A

SFS

Assumed attictruss span. TBC bystructural engineer.

Assumed attictruss span. TBC bystructural engineer.

LOOSE RAFTERS

RS RS RS

RS RS RS

Soffit & fascia to matchexisting roof.

100 x 50mm timber wallplatebedded in mortar.

Gable ladders fixed to the lasttruss with nails at 400 cts.

Insulation in wall taken 250mm above bottom of ceilingtie to gables. provide cavity tray over with weepholesat 450mm cts. provide wall ties at 750mm cts. totop of cavity tray.Double trimmers to all rooflights.

Double trimmers to all rooflights.

B B

TVTV

OBSCURE

FLUE LOCATION

C C

2100mm Ceiling Height Approx

1800mm Ceiling Height Approx

1500mm Ceiling Height Approx

Purlin Line

Ridge Line

2100mm Ceiling Height Approx

1800mm Ceiling Height Approx

1500mm Ceiling Height Approx

Purlin Line

Ridge Line

2100mm Ceiling Height Approx

1800mm Ceiling Height Approx

2100mm Ceiling Height Approx

1800mm Ceiling Height Approx

1500mm Ceiling Height ApproxW

.

W.

STORE

ENSUITEDRESSING

LANDINGM

ASTERBEDROOM

ROOFLIGHT

up

ROOFLIGHT

ROOFLIGHT

ROOFLIGHT

SVP

New Openingformed asshown.

Lintel above

2SD

FD30

FD30

TR

1225

2382

2532

7731431

751614

187675

3622

10148501787

A

A

B BSFS

C.M.E.F.

TO TILE VENT

RF3

RF4RF5

RF6

RF7

TV

C C

Full Fill Cavity Wall - Facing Brickwork

To achieve minimum U Value of 0.28W/m²K

New cavity wall to comprise of 1no leaf of 102.5 brick and 1 no leaf of100mm block K value 1.13, e.g Lafarge Stancrete; full fill cavity with 100mmDritherm32 cavity insulation as manufacturer's details. Internal finish to be 2no12.5mm plasterboard on dabs. W

alls to be built with 1:1:6 cement mortar.SFS

SD

Radiator point

SFS

BT

Low level switched fused spur outlet

2P

Double switched socket at low level

Single switched socket at high level

Fluorescent light fitting

Pendant type light fitting

High level unswitched fused spur outlet

Telephone outlet point

TR

High Level Television aerial outlet point

Low voltage downlighter

High level switched fused spur outlet

3

Mechanical extract to tile vent

Batten holder light fitting

Two way light switch

Pull cord light switch

Heat detector

ELECTRICAL LEGEND

Low level unswitched fused spur outlet

Towel Rail

Single light switch

TV

Three way light switch

Wall bracket light point

All radiator/boiler positions to refer tomanufacturers layouts.

External light

HD

Main operated interlinked smoke

detection with battery backup

All switches & sockets to be positioned between450 & 1200mm above local f.f.l.

Low Level Television aerial outlet point

Cooker Hood extract vent

Double switched socket at high level

TV

INTERNAL LIGHTINGInstall low energy light fittings that only takelamps having a luminous efficiency greaterthan 45 lumens per circuit watt and a totaloutput greater than 400 lamp lumens. Notless than three energy efficient light fittingsper four of all the light fittings in the maindwelling spaces to comply with Part L of thecurrent Building Regulations.

Carbon Monoxide Detector

SOIL VENT PIPE

DC

CMD

CONSTRUCTION LEGEND

SFGSEALED FLOOR GULLEY

SVP

INSPECTION CHAMBER

INTERNAL STUD PARTITIONS75mm x 50mm softwood treated timbers studs at 400mm cts with 50 x75mm head and sole plates and solid intermediate horizontal noggins at 1/3height or 450mm. Provide min 10kg/m³ density acoustic soundproof quilttightly packed (eg. Rockwool or Isowool mineral fibre sound insulation) in allvoids the full depth of the stud. Partitions built off doubled up joists wherepartitions run parallel or provide noggins where at right angles, or built offDPC on thickened concrete slab if solid ground floor. W

alls faced throughoutwith 12.5mm plaster board with skim plaster finish. Taped and jointedcomplete with beads and stops.

RAINWATER PIPE

DENOTES EXISTING STRUCTUREExisting structure including foundations, beams, walls and lintels carrying newand altered loads are to be exposed and checked for adequacy prior tocommencement of work and as required by the building control officer.

DENOTES WALLS TO M

ATCH EXISTING STRUCTURE

IC

DRAINAGE LEGEND

RWP

DIRECT FOUL CONNECTION

STUD DWARF W

ALLTo achieve minimum U Value of 0.28W

/m²KConstruct stud wall using 100mm x 50mm head and sole plates and verticalstuds (with noggins) at 400mm centres or to structural engineer's details andcalculations. Insulation between and over studs; 60mm Celotex GA4000between plus 37.5mm Celotex PL4000 insulated plasterboard with VCL.Finish with 3mm skim coat of finishing plaster. All junctions to have water tightconstruction, seal all perimeter joints with tape internally and with siliconsealant externally.

RevDate

Notes

NOTES:Do not scale from this drawing except for planningapplication purposes.

PROJECT:

DRAWING TITLE:

SCALE:DATE:

DRAWN:

DWG NO.

REV. Initials

Proposed Floor Plans & Elevations

1:50 1:100

MG

The Contractor is to check and verify all building and site dimensions,levels and sewer invert levels at connection points before work starts.The Contractor is to comply in all respects with current BuildingLegislation, British Standard Specifications, Building Regulations,Construction (Design & Management) Regulations, Party W

all Act, etc.whether or not specifically stated on this drawing. This drawing mustbe read with and checked against any structural, geotechnical or otherspecialist documentation provided.

This drawing is not intended to show details of foundations, groundconditions or ground contaminants. Each area of ground relied upon tosupport any structure depicted (including drainage) must be investigatedby the Contractor. A suitable method of foundation should be providedallowing for existing ground conditions. Any suspect or fluid ground,contaminates on or within the ground, should be further investigatedby a suitable expert. Any earthwork constructions shown indicate typicalslopes for guidance only & should be further investigated by a suitableexpert.

Where existing trees are to be retained they should be subject to a full

Arboricultural inspection for safety. All trees are to be planted so as toensure they are a minimum of 5 metres from buildings and 3 metres fromdrainage and services. A suitable method of foundation is to be providedto accommodate the proposed tree planting.

Sketch proposals are for illustrative purposes only & as such aresubject to detailed site investigation including groundconditions/contaminants, drainage, design & planning/densitynegotiations. Sketch proposals may be based upon enlargements ofOS sheets & visual estimations of existing site features, accuracywill therefore need to be verified by survey. Sketch proposals have notbeen considered in respect of CDM Regulations.

BUILDING REGULATIONS

1:500 1:1250 at A1

C COPYRIGHT NICHE ARCHITECTURE LTD

Proposed extension & alterations to-

Staffordshire, DE13 8SF

4 Hollybush Road

16-014-WD-102

10.08.16

Newborough

4 H O L L Y B U S H R O A D , N E W B O R O U G H

SIDE ELEVATION

REAR ELEVATION

FRONT ELEVATION

GROUND FLOOR PLANFIRST FLOOR PLAN

SECOND FLOOR PLAN

SIDE ELEVATION

PRELIMINARYSUBJECT TO STRUCTURAL CALCULATIONS,

LA & BUILDING CONTROL APPROVAL

Page 3: Working Drawing Hollybush[1]

RF3550X780

RF4660X1180

RF5RF6

RF7780X980

660X1180660X1180

Ridge Line

660100

660100

6601084

780741

11002134

5501209

Soffit & fascia to matchexisting roof.

100 x 50mm timber wallplatebedded in mortar.

Gable ladders fixed to the lasttruss with nails at 400 cts.

Insulation in wall taken 250mmabove bottom of ceiling tie togables. provide cavity tray overwith weepholes at 450mm cts.provide wall ties at 750mm cts.to top of cavity tray.

INDICATIVE ROOF PLAN

New roof pitch to match existing main roof pitchcontractor to confirm on site prior to orderingand manufacture of prefabricated roof trusses.Roof to be designed by specialist.

NOTE:-ROOF PITCH TO DETERM

INED ON SITE.PITCH TO BE SITE M

EASURE PRIOR TOANY ODERING/FABRICATION OF STEELW

ORK/ ROOF STRUCTURE.REFER TO STRUCTURAL ENGINEER'SDESIGN.

CS RS

OVERALL WALLPLATE TO BE MEASURED ON SITE

ATTIC TRUSSES

RS RSRSRS CSCS CS CSCS

Double trimmers to all rooflights.

SHOWER ROOM

WAREDROBE

EN SUITE

STORE

BEDROOM 2

DRESSINGM

ASTER BEDROOMLANDING

LANDING

HALLWAY

SITTING ROOM

BEDROOM 3

JOIST ZONE

JOIST ZONE

TO MATCH EXISTING TO MATCH EXISTING

WAREDROBE

WAREDROBE

BEDROOM 4

BEDROOM 2

DRESSING

WAREDROBE

WAREDROBE

ROOF VOIDROOF VOID

UTILITYSHOW

ERROOM

STUDYFAM

ILYW

2

W3

W4

1800mm Ceiling Height Approx

1500mm Ceiling Height Approx

2100mm Ceiling Height Approx

D3

F.F.L. TO F.F.L. TO MATCH EXISTING F.F.L. TO F.C.L. TO MATCH EXISTING

STEEL FORSTRUCTURALENGINEERDESIGN

38x50mm battens fixed to sides of raftersto restrain insulation and maintain 50mmmin. ventilation space.

50mm min. clear ventilation.

38x50mm battens fixed to sides of raftersto restrain insulation and maintain 50mmmin. ventilation space.

50mm min. clear ventilation.

9mm plywood fixed to underside of rafteronly with 3.35x75 galvanised wire nails

9mm plywood fixed to underside of rafteronly with 3.35x75 galvanised wire nails

A

A

SECTION THROUGH A.ASLOPING CEILING INSULATION DETAILScale 1:10

SLOPING CEILING INSULATION DETAILScale 1:10

100mm Xtratherm Thin-R tightlyinstalled between rafters.

Xtratherm Thin-R 45mm under rafters. Fix12.5mm foil backed plasterboard (jointsstaggered) and 5mm skim coat of finishingplaster to the underside of all ceilings usinggalvanized plasterboard nails.

100mm Xtratherm Thin-R tightlyinstalled between rafters.

Xtratherm Thin-R 45mm under rafters. Fix12.5mm foil backed plasterboard (jointsstaggered) and 5mm skim coat of finishingplaster to the underside of all ceilings usinggalvanized plasterboard nails.

OVER

ALL RO

OF C

ON

STRU

CTIO

N TO

ACH

EIVE A U-VALU

E OF 0.18 W

/m²k

FAMILY

KITCHENHALL

BATHROOMEN SUITE

LANDING

LANDINGSTORE

780x980mmROOFLIGHT

AS EXISTING AS EXISTING

38x50mm battens fixed to sides of rafters to restrain insulation and maintain 50mm min. ventilationspace.

50mm min. clear ventilation.

38x50mm battens fixed to sides of raftersto restrain insulation and maintain 50mmmin. ventilation space.

50mm min. clear ventilation.

SECTION THROUGH A.AA

SLOPING CEILING INSULATION DETAIL

SECTION THROUGH SLOPING CEILING

Breathable Roofing Felt Tyvek(or similar approved)

A

Scale 1:10

Scale 1:10

EXISTING SLOPING CEILINGS

Xtratherm Thin-R 80mm under rafters. Fix12.5mm foil backed plasterboard (jointsstaggered) and 5mm skim coat of finishingplaster to the underside of all ceilings usinggalvanized plasterboard nails.

50mm Xtratherm Thin-R tightly installed between rafters. (basedon 100mm deep rafter. If existing rsfter is deeper insulation canbe increased between and decreased below).

Xtratherm Thin-R 80mm under rafters. Fix 12.5mm foilbacked plasterboard (joints staggered) and 5mm skim coatof finishing plaster to the underside of all ceilings usinggalvanized plasterboard nails.

50mm Xtratherm Thin-R tightly installed between rafters. (basedon 100mm deep rafter. If existing rsfter is deeper insulation canbe increased between and decreased below).

RevDate

Notes

NOTES:

Do not scale from this drawing except for planningapplication purposes.

PROJECT:

DRAWING TITLE:

SCALE:DATE:

DRAWN:

DWG NO.

REV. Initials

Sections, Roof Plan &

1:50 1:100

MG

The Contractor is to check and verify all building andsite dimensions, levels and sewer invert levels atconnection points before work starts. TheContractor is to comply in all respects with currentBuilding Legislation, British Standard Specifications,Building Regulations, Construction (Design &Management) Regulations, Party W

all Act, etc.whether or not specifically stated on this drawing.This drawing must be read with and checked againstany structural, geotechnical or other specialistdocumentation provided.

This drawing is not intended to show details offoundations, ground conditions or groundcontaminants. Each area of ground relied upon tosupport any structure depicted (including drainage)must be investigated by the Contractor. A suitablemethod of foundation should be provided allowingfor existing ground conditions. Any suspect or fluidground, contaminates on or within the ground, shouldbe further investigated by a suitable expert. Anyearthwork constructions shown indicate typicalslopes for guidance only & should be furtherinvestigated by a suitable expert.

Where existing trees are to be retained they should be

subject to a full Arboricultural inspection for safety. Alltrees are to be planted so as to ensure they are aminimum of 5 metres from buildings and 3 metresfrom drainage and services. A suitable method offoundation is to be provided to accommodate theproposed tree planting.

Sketch proposals are for illustrative purposes only& as such are subject to detailed site investigationincluding ground conditions/contaminants, drainage,design & planning/density negotiations. Sketchproposals may be based upon enlargements of OSsheets & visual estimations of existing sitefeatures, accuracy will therefore need to be verified bysurvey. Sketch proposals have not been considered inrespect of CDM Regulations.

BUILDING REGULATIONS

1:10 at A1

C COPYRIGHT NICHE ARCHITECTURE LTD

Proposed extension & alterations to-

Staffordshire, DE13 8SF

4 Hollybush Road

16-014-WD-102

10.08.16

Newborough

4 H O L L Y B U S H R O A D , N E W B O R O U G H

SECTION A-ASECTION B-B

Construction Details

SECTION C-C

PRELIMINARYSUBJECT TO STRUCTURAL CALCULATIONS,

LA & BUILDING CONTROL APPROVAL

Page 4: Working Drawing Hollybush[1]

BUILDING REGULATIONS NOTES

CDM REGULATIONS 2015

The client must abide by the Construction Design and Management Regulations

2015. The client must appoint a contractor, if more than one contractor is to beinvolved, the client will need to appoint (in writing) a principal designer (to plan,manage and coordinate the planning and design work) and a principal contractor (toplan, manage and coordinate the construction and ensure there are arrangementsin place for managing and organising the project).

Domestic clientsThe domestic client is to appoint a principal designer and a principal contractorwhen there is more than one contractor, if not your duties will automaticallytransferred to the contractor or principal contractor.

The designer can take on the duties, provided there is a written agreementbetween you and the designer to do so.

The Health and Safety Executive is to be notified as soon as possible beforeconstruction work starts if the works:

(a) Last longer than 30 working days and has more than 20 workers workingsimultaneously at any point in the project.Or:(b) Exceeds 500 person days.

THERMAL BRIDGING

Care shall be taken to limit the occurrence of thermal bridging in the insulationlayers caused by gaps within the thermal element, (i.e. around windows and dooropenings). Reasonable provision shall also be made to ensure the extension isconstructed to minimise unwanted air leakage through the new building fabric.

MATERIALS AND W

ORKMANSHIP

All works are to be carried out in a workmanlike manner. All materials andworkmanship must comply with Regulation 7 of the Building Regulations, all relevantBritish Standards, European Standards, Agreement Certificates, ProductCertification of Schemes (Kite M

arks) etc. Products conforming to a Europeantechnical standard or harmonised European product should have a CE marking.

SITE PREPARATIONGround to be prepared for new works by removing all unsuitable material,vegetable matter and tree or shrub roots to a suitable depth to prevent futuregrowth. Seal up, cap off, disconnect and remove existing redundant services asnecessary. Reasonable precautions must also be taken to avoid danger to healthand safety caused by contaminants and ground gases e.g. landfill gases, radon,vapours etc. on or in the ground covered, or to be covered by the building.

EXISTING STRUCTUREExisting structure including foundations, beams, walls and lintels carrying new andaltered loads are to be exposed and checked for adequacy prior tocommencement of work and as required by the Building Control Officer.

BEAMS

Supply and install new structural elements such as new beams, roof structure, floorstructure, bearings, and padstones in accordance with the Structural Engineer'scalculations and details. New steel beams to be encased in 12.5mm GyprocFireLine board with staggered joints, Gyproc FireCase or painted in Nullifire S orsimilar intumescent paint to provide 1/2 hour fire resistance as agreed withBuilding Control. All fire protection to be installed as detailed by specialistmanufacturer.

LINTELS- For uniformly distributed loads and standard 2 storey domestic loadings onlyLintel widths are to be equal to wall thickness. All lintels over 750mm sized internaldoor openings to be 65mm deep pre-stressed concrete plank lintels. 150mmdeep lintels are to be used for 900mm sized internal door openings. Lintels tohave a minimum bearing of 150mm on each end. Any existing lintels carryingadditional loads are to be exposed for inspection at commencement of work onsite. All pre-stressed concrete lintels to be designed and manufactured inaccordance with BS 8110, with a concrete strength of 50 or 40 N/mm² andincorporating steel strands to BS 5896 to support loadings assessed to BS5977 Part 1.For other structural openings provide proprietary insulated steel lintels suitable forspans and loadings in compliance with Approved Document A and lintelmanufactures standard tables. Stop ends, DPC trays and weep holes to beprovided above all externally located lintels.

STRAPPING FOR PITCHED ROOFGable walls should be strapped to roofs at 2m centres. All external walls runningparallel to roof rafters to be restrained at roof level using 1000mm x 30mm x5mm galvanised mild steel horizontal straps or other approved to BSEN 845-1built into walls at max 2000mm centres and to be taken across minimum 3 raftersand screw fixed. Provide solid noggins between rafters at strap positions. All wallplates to be 100 x 50mm fixed to inner skin of cavity wall using 30mm x 5mm x1000mm galvanized metal straps or other approved to BSEN 845-1 at maximum2m centres.

STRAPPING OF FLOORSProvide lateral restraint where joists run parallel to walls, floors are to be strappedto walls with 1000mm x 30mm x 5mm galvanised mild steel straps or otherapproved in compliance with BS EN 845-1 at max 2.0m centres, straps to betaken across minimum of 3 joists. Straps to be built into walls. Provide 38mm widex ¾

depth solid noggins between joists at strap positions.

STRIP FOUNDATIONProvide 225mm x 600mm concrete foundation, concrete mix to conform to BS EN206-1 and BS 8500-2. All foundations to be a minimum of 1000mm belowground level, exact depth to be agreed on site with Building Control Officer to suitsite conditions. All constructed in accordance with 2004 Building RegulationsA1/2 and BS 8004:1986 Code of Practice for Foundations. Ensure foundationsare constructed below invert level of any adjacent drains. Base of foundationssupporting internal walls to be min 600mm below ground level. Sulphate resistantcement to be used if required. Please note that should any adverse soil conditionsbe found or any major tree roots in excavations, the Building Control Officer is tobe contacted and the advice of a structural engineer should be sought.

WALLS BELOW

GROUNDAll new walls to have Class A blockwork below ground level or alternatively semiengineering brickwork in 1:4 masonry cement or equal approved specification.Cavities below ground level to be filled with lean mix concrete min 225mm belowdamp proof course. Or provide lean mix backfill at base of cavity wall (150mmbelow damp course) laid to fall to weepholes.

DPCProvide horizontal strip polymer (hyload) damp proof course to both internal andexternal skins minimum 150mm above external ground level. New DPC to be madecontinuous with existing DPC’s and with floor DPM

. Vertical DPC to be installed atall reveals where cavity is closed.

WALL TIES

All walls constructed using stainless steel vertical twist type retaining wall ties builtin at 750mm ctrs horizontally, 450mm vertically and 225mm ctrs at reveals andcorners in staggered rows. W

all ties to be suitable for cavity width and inaccordance with BS 5628-6.1: 1996 and BS EN 845-1: 2003

CAVITIESProvide cavity trays over openings. All cavities to be closed at eaves and aroundopenings using Thermabate or similar non combustible insulated cavity closers.Provide vertical DPCs around openings and abutments. All cavity trays must have150mm upstands and suitable cavity weep holes (min 2) at max 900mm centres.

EXISTING TO NEW W

ALLCavities in new wall to be made continuous with existing where possible to ensurecontinuous weather break. If a continuous cavity cannot be achieved, where newwalls abuts the existing walls provide a movement joint with vertical DPC. All tiedinto existing construction with suitable proprietary stainless steel profiles.

SMOKE DETECTION

Mains operated linked smoke alarm detection system to BS EN 14604 and

BS5839-6:2004 to at least a Grade D category LD3 standard and to bemains powered with battery back up. Smoke alarms should be sited so thatthere is a smoke alarm in the circulation space on all levels/ storeys and within7.5m of the door to every habitable room. If ceiling mounted they should be300mm from the walls and light fittings. W

here the kitchen area is notseparated from the stairway or circulation space by a door, there should bean interlinked heat detector in the kitchen.

ROOF LIGHTSM

in U-value of 1.6 W/m²K.

Roof-lights to be double glazed with16mm argon gap and soft low-E glass.W

indow Energy Rating to be Band C or better. Roof lights to be fitted inaccordance with manufacturer's instructions with rafters doubled up to sidesand suitable flashings etc.

SAFETY GLAZINGAll glazing in critical locations to be toughened or laminated safety glass toBS 6206, BS EN 14179 or BS EN ISO 12543-1:2011 and Part K (Part Nin W

ales) of the current Building Regulations, i.e. within 1500mm above floorlevel in doors and side panels within 300mm of door opening and within800mm above floor level in windows.

NEW AND REPLACEM

ENT WINDOW

SNew and replacement windows to be double glazed with 16mm argon gap andsoft coat low-E glass. W

indow Energy Rating to be Band C or better and toachieve U-value of 1.6 W

/m²K. The door and window openings should belimited to 25%

of the extension floor area plus the area of any existingopenings covered by the extension.

NEW AND REPLACEM

ENT DOORSNew and replacement doors to achieve a U-Value of 1.80W

/m²K. Glazed areasto be double glazed with 16mm argon gap and soft low-E glass. Glass to betoughened or laminated safety glass to BS 6206, BS EN 14179 or BS ENISO 12543-1:2011 and Part K (Part N in W

ales) of the current BuildingRegulations.

BACKGROUND AND PURGE VENTILATIONBackground ventilation - Controllable background ventilation via trickle ventsto BS EN 13141-3 within the window frame to be provided to new habitablerooms at a rate of min 5000mm²; and to kitchens, bathrooms, W

Cs and utilityrooms at a rate of 2500mm²Purge ventilation - New W

indows/rooflights to have openable area in excess of1/20th of their floor area, if the window opens more than 30° or 1/10th oftheir floor area if the window opens less than 30°Internal doors should be provided with a 10mm gap below the door to aid aircirculation.Ventilation provision in accordance with the Domestic Ventilation ComplianceGuide.

EXTRACT TO BATHROOMBathroom to have mechanical vent ducted to external air to provide min 15litres / sec extraction. Vent to be connected to light switch and to have 15minute over run if no window in room. Internal doors should be provided with a10mm gap below the door to aid air circulation. Ventilation provision inaccordance with the Domestic Ventilation Compliance Guide. Intermittentextract fans to BS EN 13141-4. All fixed mechanical ventilation systems,where they can be tested and adjusted, shall be commissioned and acommissioning notice given to the Building Control Body.

EXTRACT TO UTILITY ROOMTo utility room provide mechanical ventilation ducted to external air capable ofextracting at a rate of 30 litres per second. Internal doors should beprovided with a 10mm gap below the door to aid air circulation. Ventilationprovision in accordance with the Domestic Ventilation Compliance Guide.Intermittent extract fans to BS EN 13141-4. All fixed mechanical ventilationsystems, where they can be tested and adjusted, shall be commissioned anda commissioning notice given to the Building Control Body.

EXTRACT TO KITCHENKitchen to have mechanical ventilation with an extract rating of 60l/sec or30l/sec if adjacent to hob to external air, sealed to prevent entry of moisture.Internal doors should be provided with a 10mm gap below the door to aid aircirculation. Ventilation provision in accordance with the Domestic VentilationCompliance Guide. Intermittent extract fans to BS EN 13141-4. Cookerhoods to BS EN 13141-3. All fixed mechanical ventilation systems, wherethey can be tested and adjusted, shall be commissioned and a commissioningnotice given to the Building Control Body.

PITCHED ROOF VENTILATIONM

aintain a 50mm air gap above insulation in the roof pitch to ventilate roof.Provide opening at eaves level at least equal to continuous strip 25mm wideand opening at ridge equal to continuous strip 5mm wide to promoteventilation.

RAINWATER DRAINAGE

New rainwater goods to be new 110mm UPVC half round gutters taken andconnected into 68mm dia UPVC downpipes. Rainwater taken to newsoakaway, situated a min distance of 5.0m away from any building, via 110mmdia UPVC pipes surrounded in 150mm granular fill. Soakaway to be min of 1cubic metre capacity (or to depth to Local Authorities approval) with suitablegranular fill and with geotextile surround to prevent migration of fines. Ifnecessary carry out a porosity test to determine design and depth ofsoakaway.

LEANTO

FLASHIN

G D

ETAIL.SC

ALE : 1/10.

Refer to manufacturers instructions for fixingdetails.

Code 4 lead cover flashing

Spacer bracket

Anchors to be M8 has rod

with HILTI HIT HY 70 resin.(80mm embedment)

Hilti resin anchors at 300mm horizontal c/c(only 1 per location) vertical offset betweenadjacent bolts 75mm as shown. bolt intocentre of brick.

75

50 x 200mm high wallplateproprietary angle bracket toboth sides of rafter.

Vapour permeable underlay (Type LR) toprovide a cold roof. underlay left short oflast batten to provide ventilation gap.

Glidevale MR50 monovent or

similar approved.

Double rafter/trimmerswhere necessary

INDICATIVE SECTION THRO PITCHED ROOFLIGHT DETAILScale 1:5

ROOF LIGHTS TO BE INSTALLED IN STRICTACCORDANCE W

ITH THE MANUFACTURERS DETAILS AND

RECOMM

ENDATIONS 25mm Celotex FR5000 tightlyinstalled between rafters.

70mm Celotex FR5000 to underside of rafters. Fix12.5mm foil backed plasterboard (joints staggered) on25x47mm battens and 3mm skim coat of finishing plasterto the underside of all ceilings using galvanizedplasterboard nails.

38x50mm battens fixed to sides of raftersto restrain insulation and maintain 50mmmin. ventilation space.

50mm min. clear ventilation.

Steel Beams/Columns size dependent on plot workingdrawing - Refer to Structural Engineers calculations

2 No. layers of 12.5mm British Gypsum'Gyproc' standard plasterboard

Timber packers to web of steel beam to supporttimber battens to in turn support fixing of plasterboard

38 x 38mm timber battens

For steel connections refer to specific locationwhere situation occurs (indicative only).

Ceiling finish (generally 15mm Gyproc wallboard)

Fire Protection To Structural SteelScale 1:10

Existing wall

Alternatively paint in Nullifire S or similar intumescentpaint to provide 1/2 hour fire resistance.

EXTERNAL WALL DETAIL

SCALE 1

:10

1200 gauge polythene dpm turned up edgeof slab and lapped with dpc50mm (average) sand blinding

Clean hardcore compactedin separate 150mm layers

Finished ground level

dpc min. 150mm above ground level

Weak mix concrete fill to

cavity

25mm thick insulation upstand toexternal walls.

12.5mm standard wallboard (nominal 8kg/m²)on dabs

100mm Celotex FF4000 insulation

100mm ST2 or Gen2 ground bearing slabconcrete mix to conform to BS 8500-2

65mm sand/cement finishing screed withlight mesh reinforcement

foundations to suit site conditions andto the approval of the Building Inspector.

CL CLCL

bell cast (render stop) bead

TO A

CHEIV

E A U

-VALU

E OF 0

.21

W/m

²k O

VER

ALL FLO

OR C

ONSTR

UC

TION

RevDate

Notes

NOTES:Do not scale from this drawing except for planningapplication purposes.

PROJECT:

DRAWING TITLE:

SCALE:DATE:

DRAWN:

DWG NO.

REV. Initials

MG

The Contractor is to check and verify all building and site dimensions,levels and sewer invert levels at connection points before work starts.The Contractor is to comply in all respects with current BuildingLegislation, British Standard Specifications, Building Regulations,Construction (Design & Management) Regulations, Party W

all Act, etc.whether or not specifically stated on this drawing. This drawing mustbe read with and checked against any structural, geotechnical or otherspecialist documentation provided.

This drawing is not intended to show details of foundations, groundconditions or ground contaminants. Each area of ground relied upon tosupport any structure depicted (including drainage) must be investigatedby the Contractor. A suitable method of foundation should be providedallowing for existing ground conditions. Any suspect or fluid ground,contaminates on or within the ground, should be further investigatedby a suitable expert. Any earthwork constructions shown indicate typicalslopes for guidance only & should be further investigated by a suitableexpert.

Where existing trees are to be retained they should be subject to a full

Arboricultural inspection for safety. All trees are to be planted so as toensure they are a minimum of 5 metres from buildings and 3 metres fromdrainage and services. A suitable method of foundation is to be providedto accommodate the proposed tree planting.

Sketch proposals are for illustrative purposes only & as such aresubject to detailed site investigation including groundconditions/contaminants, drainage, design & planning/densitynegotiations. Sketch proposals may be based upon enlargements ofOS sheets & visual estimations of existing site features, accuracywill therefore need to be verified by survey. Sketch proposals have notbeen considered in respect of CDM Regulations.

BUILDING REGULATIONS

at A1

C COPYRIGHT NICHE ARCHITECTURE LTD

Proposed extension & alterations to-

Staffordshire, DE13 8SF

4 Hollybush Road

16-014-WD-104

10.08.16

Newborough

4 H O L L Y B U S H R O A D , N E W B O R O U G H

Construction Notes

PRELIMINARYSUBJECT TO STRUCTURAL CALCULATIONS,

LA & BUILDING CONTROL APPROVAL


Recommended