World Leading Air Sterilization and Purification Equipment VK-002/102 USER GUIDE & INSTRUCTIONS Sales & Design: Radic8 Ltd Man & Scythe Building 6 - 8 Churchgate Bolton, BL1 1HL, UK Tel : +44 (0)1204 238823, E-mail: [email protected], www.radic8.com Manufacturer: INBair Co., Ltd 3F, 15, Beotkkot-ro 12-gil,Geumcheon-gu, Seoul, Korea Tel: +82-31-811-1000, E-mail: [email protected], www.inbair.com Made in Korea, Designed in England
Transcript
Page 1: World Leading Air Sterilization and Purification Equipment ...€¦ · • To prevent overload, do not share the same power supply socket with too many other electronic components.

WorldLeadingAirSterilizationand

PurificationEquipment VK-002/102

USERGUIDE&INSTRUCTIONS

Sales&Design:Radic8LtdMan&ScytheBuilding6-8ChurchgateBolton,BL11HL,UK

Tel:+44(0)1204238823,E-mail:[email protected],www.radic8.com

Manufacturer:INBairCo.,Ltd3F,15,Beotkkot-ro12-gil,Geumcheon-gu,Seoul,Korea

Tel:+82-31-811-1000,E-mail:[email protected],www.inbair.comMadeinKorea, Designed in England

Page 2: World Leading Air Sterilization and Purification Equipment ...€¦ · • To prevent overload, do not share the same power supply socket with too many other electronic components.

TableofContents

SafetyInstructions……………………………………………………………………………..……….……1

OperationInstructions……………………………………………………..……………………………..4

KeyPartsandComponents………………………………………………………………………………5

VirusKillerFunctions……………………………………………………………………………….……….8

CleaningandMaintenance………..…………………………………………………………….…….14

ErrorMessages……………………………………………………………………….……………………..18

Troubleshooting……………………………………………………………………………………………..20

CustomerService…………………………………………………………………………………………...21

Specifications………………………………………………………………………………………………….22

LimitedWarrantyCard

ImportantSafetyInstructions

Thefollowinginstructionsareprovidedtoensureyoursafetyandtoprotecttheunitfrom

accidentaldamage.

• Readtheseinstructions–Allthesafetyandoperatinginstructionsshouldberead

beforethisproductisoperated.

• Keeptheseinstructions–Thesafetyandoperating instructionsshouldberetained

forfuturereference.

• Heedallwarnings–Allwarningsontheapplianceandintheoperatinginstructions

shouldbeadheredto.

• Followallinstructions–Allinstructionsforuseandoperationshouldbefollowed.

Warranty–includedinside

1

Page 3: World Leading Air Sterilization and Purification Equipment ...€¦ · • To prevent overload, do not share the same power supply socket with too many other electronic components.

Warning–Thissymbolindicatesimportantsafetyinstructionsthatmustbefollowedtoavoidinjury.

Caution–Thissymbolistobringimportantinformationtoyourattentiontoavoidtheriskofinjuryordamagetotheunit.

Prohibited–Thissymbolindicatesaforbiddenaction.Adheretothesetoreducetheriskofinjuryordamagetotheunit.

ElectricalSafety

• The unit should only be connected to a properly grounded mains power supply withvoltagethatmatchesthatspecified.

• Topreventoverload,donotsharethesamepowersupplysocketwithtoomanyotherelectroniccomponents.

• Donotplacethepowercordwhere itcouldbesteppedonortrippedover.

• Donotplaceheavyitemsonthepowercord,theycoulddamagethewire.

• Do not allow water or moisture to enter the unit or poweradapter.

• Do not use in wet, moist areas such as bathrooms, steamykitchensornearswimmingpools.

• Pulltheplugoutimmediatelyandseekprofessionalhelpiftheplugorpowercordisdamaged,liquidisspilledontotheunit,ifitisaccidentallyexposedtomoistureortheunitisnotworkingnormally.

OperationSafety

• Keeptheproductawayfromflammablegasesandliquids,candlesandopenflames.

• Donot installnearanyheatsourcessuchasradiators,stoves,orotherapparatusthatproduceheat.

• Do not attempt to repair or replace any part of this equipmentunless it is specifically recommended in theuserguide.Allotherservicesshouldbereferredtoaqualifiedtechnician.

• Makesurethepowercordispluggedfirmlyandcompletelyintotheoutlet.

• Holdthemainplug,notthewires,whenremovingfromasocket.

• Duringathunderstormswitchofftheunitandunplugfromthesocket.

• Donothandletheunitwithwethands.

• Only clean with a soft,dry cloth. Do not usesolvents or petroleumbasedfluids.

• Do not place heavyobjectsontheunit.

• Do not shake, knock ormove the product whilein operation, you maydamage the internalcircuits.

• Ifastrangesmell,noise,orsmokeisemitted,turnoffimmediatelyandcontactcustomerservices.

2 3

Page 4: World Leading Air Sterilization and Purification Equipment ...€¦ · • To prevent overload, do not share the same power supply socket with too many other electronic components.

OperationInstructions

• Switchoffwhilecleaningtheroom

After cleaning, it is important to properly ventilate the roombeforeusingVirusKilleragain.

• Switchoffwhilecooking

Oils released while cooking may reduce the lifespan of thesterilizingmodule.Aftercooking,theroomshouldbeventilatedtoremoveoils.VirusKillercanthenbeusedtoremovetheremainingsmell.

• Ensureairflowisnotrestricted

DonotpositionVirusKillersothatairflowtoandfromtheunitisrestricted by large items such as furniture, electronic items orcurtains.

• Positionatleast3metresfromthebed

Toavoidexcessivecoolingcausedfromsleepingindirectairflow,werecommendpositioningVirusKilleratleast3metresawayfromthebed.

• Maintainproperventilation–30minutesperday

VirusKIllerisdesignedtopurifyandsterilizeyourindoorair,andwill do this very effectively if used correctly. Good indoor airqualityalsorequiresproperventilation.Werecommendopeningwindowsordoors,oroperatingA/Cunits,foratleast30minutesaday.

• Maintainregularservicingandmaintenance

Caution

• Theapplianceisnottobeusedbychildrenorpersonswithreducedphysical,sensoryormentalcapabilities.Thisapplianceisnotatoy.Childrenshouldbesupervisedatalltimes.

• Neverlookdirectlyataburningultra-violetlight–thismaypermanentlydamageyoureyes.Switchoffandunplugbeforeperformingmaintenance.

KeyPartsandComponents

VK-102 VK-002

4 5

Page 5: World Leading Air Sterilization and Purification Equipment ...€¦ · • To prevent overload, do not share the same power supply socket with too many other electronic components.

VK-102InternalStructure

ControlPanelandDisplay

LEDIndicatorsDUSTandVOC’sLED,colorindicatesairquality:blue–good,yellow–normal,red–poorFILTERLED,colorindicatesstatus:blue–OK,red–dueforreplacement

MODULELED,colorindicatesstatus:blue–OK,red–Reactordueforreplacement

RemoteController

6 7

(STERILIZING MODULE)

Page 6: World Leading Air Sterilization and Purification Equipment ...€¦ · • To prevent overload, do not share the same power supply socket with too many other electronic components.

VirusKillerFunctions

AutomaticOperationMode

Whentheunitisswitchedon,eitherbythepowerswitchonthemaincontrolboardortheon/offbuttonontheremotecontrol,theproductisinautomaticmode.BlueLEDlightsaredisplayedandthefanissettoquietmode(FAN1).IfsmallamountsofdustorVOC’saredetectedbythesensor,theLEDcolorchangestoyellow.IfhighlevelsofdustorVOC’saredetected,theLEDchangestoredandthefanspeedswitchestofullpower(FAN3).WhenthedustorVOClevelsreturntohealthylevels,theunitautomaticallyreturnstoquietmodeanddisplaystheblueLED.

· BlueLED–AirqualityisGOOD

· YellowLED–AirqualityisNORMAL

· RedLED–AirqualityisPOORNote–WhentheunitisswitchedontheIndoorAirQualitysensor(IAQ)takes2minutestocalibrate.

Whenpowerbuttonispressed,theproductemitsabeepsoundandbeginstooperate.Iftheproductdoesnotoperate,ensurethesocketispluggedsecurelyintoalive,properlygroundedoutletofthecorrectvoltage.

ManualOperationMode

Ifyouwishtostopautomaticmodeandmanuallyoperatetheunit,pressanybuttononthemainboardorontheremotecontrol.Youmaythenoperatetheunitasshownbelow.

· IncreasingtheFanSpeed

Pressupbuttononmainboard①orPress▲buttonofremotecontroller②FanspeedwillincreasewhentheUPbuttonispressedandtheunitwillbeep.

FAN1QuietMode

FAN2NormalMode

FAN3HighSpeedMode

8 9

Page 7: World Leading Air Sterilization and Purification Equipment ...€¦ · • To prevent overload, do not share the same power supply socket with too many other electronic components.

· ReducingtheFanSpeed

Pressdownbuttononmainboard①or

Press ▼ buttonofremotecontroller②

FanspeedwilldecreasewhentheDOWNbuttonispressedandtheunitwillbeep.FAN1QuietMode

FAN2NormalMode

FAN3HighSpeedMode

OperatingtheUVCLamp

PressUVCbuttononmainboard①Pressing theUVCbuttonswitches theUVCLampoff; theunitwillbeepandtheUVCbuttonwillnotbelit.PressingtheUVCbuttononcemoreswitchesontheUVCLamp.

10

OperatingtheLEDMoodLamp

PressLEDbuttononmainboard①orPressLAMPbuttononremotecontroller②

11

Page 8: World Leading Air Sterilization and Purification Equipment ...€¦ · • To prevent overload, do not share the same power supply socket with too many other electronic components.

SettingtheTimer

PressTIMERbuttononmainboard①orTIMERonremotecontroller②

RepeatedlypressingTIMERwilltogglethroughthepresetoptions.Theunitwillautomaticallyswitchoffwhentheprogrammedtimehaspassed. Pr-3 3hourspresetPr-6 6hourspresetPr-9 9hourspreset

ModeIndicator

RepeatedlypressingtheMODEbuttonontheremotecontroller ②

changesthedisplayinthefollowingorder:0001 Operationtime(inhours)ofSterilizingModule

_27d CurrenttemperatureFAN3 FanSpeed

12

SwitchingtheUnitOff

PressPoweroffswitchonmainboard ① or

PressPoweroffswitchonremotecontroller ②Toswitchtheunitoff,pressthePOWERbuttonontheunitorontheremotecontrol. Turntheproductoffandunplugpowercordwhennotinuseforanextendedperiodoftime.

13

Page 9: World Leading Air Sterilization and Purification Equipment ...€¦ · • To prevent overload, do not share the same power supply socket with too many other electronic components.

CleaningandMaintenance

CleaningthePre-Filter

Theplasticpre-filterisreusable.Tocleanitfollowthisprocedure:

1. Pulloutthefiltercase ①.

2. Removepre-filtercase ② fromfiltercase ① andseparatefromcarbonfilter ③

andHEPAfilter ④.

3. Cleanthepre-filterwithplainwater. 4. Allowtodrycompletelyoutofdirectsunlight.5. ReplaceEnsureyouhaveremovedtheHEPAandcarbonfiltersbeforewashingthepre-filter

We recommend you check the pre-filter regularly and clean it as often as necessary,dependingonthelevelsofpollution. 14

ReplacingtheCarbonFilterandHEPAFilter

Every2000hourstheFILTERLED①changescolorfrombluetored,indicatingitistimetoreplacetheHEPAandcarbonfilters.Afterreplacingthefilters(asshownabove)press

andholdtheUPswitch ② foratleast5secondstoresettheFILTERtimertozero.

TheHEPAandcarbonfiltersarenotreusableandshouldbereplaced. DependingonthelevelsofpollutionthelifetimeoftheHEPAandcarbonfiltersmaybelongerorshorterthantherecommended2000hoursusetime.

Please contact your local customer service center or distributor to purchasereplacementHEPAandcarbonfilters.

15

Page 10: World Leading Air Sterilization and Purification Equipment ...€¦ · • To prevent overload, do not share the same power supply socket with too many other electronic components.

ReplacingtheReactorCell

Every8000hourstheMODULELED①changescolorfrombluetoredandthedisplay

showsaminusfigure ②,indicatingitistimetoreplacetheReactorCell(alsocalledthe

SterilizingModule).

CAUTIONTheReactorCellisnotreusableandshouldbereplaced. The Reactor Cell is a complex and high voltage piece of equipment. Users are notpermittedtoattemptrepairorreplacement.Allworkistobecarriedoutbyaqualifiedtechnician.Please contact your local customer service center or distributor to arrange for theReactorCelltobereplaced.

REACTORCELLVK-102 VK-002

16

CleaningtheIndoorAirQuality(IAQ)Sensor

TheIAQsensorisaverydelicateinstrumentthatuseslightscatteringtodetectpollution.Ittherefore needs a clean lens to work effectively. Regular maintenance (every 6 months)shouldbecarriedouttokeepthelensclean. Important - Only use purewater and allow to dry completely before replacing. To avoiddamagetotheplasticlensdonotusechemicalssuchasbenzeneoralcoholetc. ProceduretomaintainandcleantheIAQSensor:

1. LocatetheIAQsensoronthesideoftheunit2. Cleanlenswithacleancottonswabdampenedwithpurewaterasshownbelow.3. Allowlenstodrycompletely.

CAUTION Donotspraywaterorperfumenearthesensor.

Page 11: World Leading Air Sterilization and Purification Equipment ...€¦ · • To prevent overload, do not share the same power supply socket with too many other electronic components.

18 19

ErrorMessages

ReactorCellReplacementDue

When the display shows a minus figure the Reactor Cell (Sterilizing Module) is due forreplacement. It is importanttoarrangethiswhenpromptedtoavoidanyreduction inthesterilizingpowerandlifespanoftheunit.Switchofftheunitandcontactthecustomerservicecenter.

CircuitOverheatError

Thebelowerrormessageisdisplayedwhenthecircuitisoverheated.Switchofftheunitandcontactthecustomerservicecenter.

17

WhentoReplacetheCarbonandHEPAFilter

WhentheFILTERLED①changesfrombluetored,itistimetoreplacetheHEPAandcarbon

filters.Afterreplacingthefilters,pressandholdtheUPswitch ② foratleast5secondsto

resettheHEPAtimertozero.

PleasecontactyourlocalcustomerservicecenterordistributortopurchasereplacementHEPAandcarbonfilters.

PoorAirQualityIndicator

WhenfinedustandVOC’saredetectedatunhealthylevelsbytheIAQsensor,theDUST ①

andVOC’s ② LEDlightswillchangefromredtoblue.VirusKillershouldbesettoFAN3and

theroomventilatedtoimprovetheairquality.TheLEDlightswillchangetobluewhentheairqualityhasreturnedtohealthylevels.

Page 12: World Leading Air Sterilization and Purification Equipment ...€¦ · • To prevent overload, do not share the same power supply socket with too many other electronic components.

Troubleshooting Beforeyoucallforservice,reviewthislist.Itmaysaveyoutimeandexpense.Thislistincludescommonoccurrencesthatarenottheresultofdefectinworkmanshipormaterials.

Problem–Productwillnotturnon.Q. Ispowercordcorrectlyconnectedtooutlet?A. PutpowerplugintoACoutletandDCjackagain.

Q. Checkremotecontroller?A. Change/reinstallbatteriescorrectlyaccordingtothepolarity.Q. Checktheoutlet?A. Thisproductshouldbepluggedintoaproperlygroundedoutletwiththecorrect

voltage(asshownonthebackoftheunit).

Problem–Theairpurifyingfunctionisnoteffective.Q. Istheairintheroomseriouslycontaminated?A. Useonlyaftersufficientventilation,minimum30minutes.Q. Checkifthepre-filterisheavilycontaminated.A. Cleanthepre-filterQ. CheckiftheHEPAfilterisheavilycontaminated.A. ReplaceHEPAfilter.

Q. Checktheroomsizecomparedtotheproductspecifications.A. SelecttheappropriatemodelofVirusKillertosuitthespacetobecovered.Q. Checkifairflowisrestricted?A. Makesurethereissufficientclearancearoundtheproductandthattheairinletand

outletarenotblockedbyfurniture,curtains,etc.

20

Problem–TheunitisemittingastrangesmellQ. Isthisa‘newproduct’smell?A. Itmaybeanantimicrobialsmellemittedbythesterilizingmoduleorfiltersandwill

disappearoverashortperiodofoperation(1-2weeks).Itiscompletelyharmlesstohumansandanimals.

Q. Isthewashablepre-filtercompletelydry?A. Thismaybe from thepre-filter if replacedbeforedry.Remove,washagain, and

allowtodrycompletelybeforefurtheroperation.Q. Hastheunitbeenusedduringorshortlyaftercooking?A. Somefoododorscanpermeateintothefilterorsterilizingmodule.Onlyswitchon

theunitaftersufficientventilation.Q. Hastheunitbeenusedwherethereareheavyemissionsofsmokeorodors?A. Inareasemittingsmokeorodors,theperformanceofthesterilizingmodulemaybe

affected.Useafterventilation.

Problem–Weakwindvolumeorunusualnoisefromtheproduct.Q. Checkifdusthasaccumulatedinthefilter?A. Filtersshouldbereplacedorcleanedatappropriatetime.

21

Page 13: World Leading Air Sterilization and Purification Equipment ...€¦ · • To prevent overload, do not share the same power supply socket with too many other electronic components.

CustomerServicesInthismanual,youwillfindacardcontainingdetailsofyourlimitedwarrantyandcontact

detailsforyourlocalcustomerservicescenter,towhomallenquiriesandwarrantyclaims

shouldbedirected.

Allwarrantiesarerenderedvoidandthecostofrepairwillbepayablebytheuserinthe

caseof:

1. Damagescausedbyputtingforeignobjects(suchaswater,softdrink,coffee,

fragranceoilsortoyetc.)inorontheunit.

2. Damagescausedbytransportationorhandling.

3. Damagescausedbyuseofproductssuchasbenzeneorthinner.

4. Damagescausedbyusingincorrectpowersupplyoroutputvoltage.

5. Breakdownorlossofpartscausedbyunauthorizeddisassemblingor

modification.

6. Repairorreplacementundertakenbyunauthorizedpersons.

7. Damagescausedbynon-adherencetotheinstructionsprovidedinthisuserguide,

andasgivenbythelocalcustomerservicecenter.

8. Damagescausedbycarelessorimproperuse.

9. Damagescausedbyoperatingtheproductinacorrosiveormoistenvironment.

22

Specifications

VK-102 VK-002

Thecompanyreservestherighttomakechangestotheexterior,designorspecificationsoftheproductwithoutpriornotice.

Description AirPurifier AirPurifier

Brand VIRUSKILLER VIRUSKILLERModelNo VK-102 VK-002Elec.Power Checkbackofunit Checkbackofunit

Elec.Consumption 350watt 280wattNetWeight 40Kg 29KgGrossWeight 44Kg 33KgNetDimension 1570x320x320mm 1220x320x320mmBoxDimension 1680x460x440mm 1340x460x440mm