+ All Categories
Home > Documents > wT'* lill - smartcityaligarh.com · wt'*},tq* lill request for proposal for selection of master...

wT'* lill - smartcityaligarh.com · wt'*},tq* lill request for proposal for selection of master...

Date post: 06-Mar-2019
Category:
Upload: hoangkien
View: 220 times
Download: 0 times
Share this document with a friend
9
wT'* },Tq* lill REQUEST FOR PROPOSAL FOR SELECTION OF MASTER SYSTEM INTEGRATOR FOR IMPLEMENTATION OF INTEGRATED COMMAND & CONTROL CENTER AND e- GOVERNANCE BASED SMART CITY SOLUTION AT ALIGARH NfT Number: L4l ASCLI2OLS-l9: Dated O3l1-2l2OL8 ADDENDUM: 01 Date:13/12/2018 eA Fil ft.r/
Transcript
Page 1: wT'* lill - smartcityaligarh.com · wt'*},tq* lill request for proposal for selection of master system integrator for implementation of integrated command & control center and e-governance

wT'*},Tq* lill

REQUEST FOR PROPOSAL FOR SELECTION OF MASTER

SYSTEM INTEGRATOR FOR IMPLEMENTATION OF

INTEGRATED COMMAND & CONTROL CENTER AND e-

GOVERNANCE BASED SMART CITY SOLUTION AT ALIGARH

NfT Number: L4l ASCLI2OLS-l9: Dated O3l1-2l2OL8

ADDENDUM: 01

Date:13/12/2018

eAFil ft.r/

Page 2: wT'* lill - smartcityaligarh.com · wt'*},tq* lill request for proposal for selection of master system integrator for implementation of integrated command & control center and e-governance

*'l'.-tf! !:it

RFP for Selection of MSI for implementation of ICCC and e-Gov based Smart City solution at Aligarh =-;::,;;

Annexure 8.57. Workstation/Desktop

7 Processors

Latest generation X86 Processor

3.2 Ghz or Higher

Min 8 MB

2

Mother Board

Latest series 64 bit chipsetEither on the Display system or on chassis

or external OEM speaker

Intel/OEM16 GB DDR-IV (2400 MHz) or higherexpandable up to 64 GB

GraohicsCard-2GB

1x PCle x15 and 1 PCle x4 (total minimum 2 PCI Slots)

3 Display

2L.5" or hieher

Active Matrix TFT LCD {Backlit LED)

1920x1080 or hieher

4

Miscellaneous

Minimum 5 USB Ports (minimum two USB 3.0 ports

and minimum 2 USB port 2.0 or higher in front)LOItOO/LOOO Ethernet Card, VGA/HDMl, Display

Port/HDMI/DVI, Microphone & Stereo Head Phone/Comboport and other standard ports, tool less cabinet, TPM 2.0

External/lnternal 180 W or higher Power supply(>=85% efficient), Active PFC

Tower

5Mouse

OpticalDriveKeyboard

Optical/Laser USB

Internal 8x or higherStandard USB

6 Operating SystemPreloaded Windows 10 Prof 64 bit Windows/Linux Ubuntu

7 HDD1TB SATA (7200 RPM) or higher capacity

Addendum

,.\l\ //f

Page 3 of10

/hl

&rfu A/#

Page 3: wT'* lill - smartcityaligarh.com · wt'*},tq* lill request for proposal for selection of master system integrator for implementation of integrated command & control center and e-governance

ii:. : .:ii.Hi i:ii

RFP for Selection of MSI for implementation of ICCC and e-Gov based Smart City solution at Aligarh - ". ' "

- Smart City

Annexure 8.58. BackuP Software

1

Proposed backup software should be available on various OS platforms like

Windows, Linux, HP-UX, IBM AlX, Solaris etc. The backup server should be

compatible to run on both Windows and Linux OS platfgqn!-

2

The backup software should be able to encrypt the backed up data using

256-bit AES encryption on the backup client and should not demand for

additional license, any such license if needed should be quoted for the total

number of backup clients asked for.

3

Th" b..kfi solriion should also support online LAN Free SAN based backups

of databases through appropriate agents; lmportant Applications being

Oracle, Microsoft SQL Server, Exchange, SharePoint, IBM DB2 UDB, lnformix,

Lotus Notes/Domino, MySQL, SAP, SAP HANA & SL

4

Should able to dynamically break up large savesets into smaller savesets to

be backed up in parallel to allow backups to complete faster for windows,

Unix and Linux clients.

5

Should have in-built calendar based scheduling system and also support

check-point restart able backups for file systems. lt should support various

level of backups including full, incremental, differential, synthetic and virtual

svnthetic backups

6

The proposed backup software should have the capability to enable woRM

on the backup sets from the backup software console on proposed disk

backup appliance

1The solution must support client-direct backup feature for file system,

applications and databases to reduce extra hop for backup data at

backup/media server to cater stringent backup window,

8Must support source capacity based licensing and host based licensing as

well.

9

Must have Agent/Modules for online backup of applications and databases

such as MS SQL, Oracle, Exchange, Lotus, DB2, Informix, SAP. Must support

NAS and storage array based snapshot backup for off host zero downtime

and zero load on the primary backup client with wizard based configuration

10

Backup Solution must support multi tenanry feature for creation of distinct

data zones where the end users have access without being able to view

data, backups, recoveries, or modify in other data zones.

11The proposed backup software should support restore a single VM, single

file from a VM restore from the same management console for ease of use.

L2

fne proposed solution should have inbuilt feature for extensive alerting and

reporting with pre-configured and customizable formats. The proposed

solution must have capability to do trend analysis for capacity planning of

backup environment not limiting to Backup Application/Clients, Virtual

Environment, Replication etc.

13

The proposed backup software should support deployment in public, private

and hosted clouds. The backed up data written to cloud volumes should flow

directly from Clients to cloud storage without intervention of media server

in data path. The Clients writing to cloud storage using the proposed backup

software should have source based deduplication, compression and

Page 4 of 10Addendum

At"

Page 4: wT'* lill - smartcityaligarh.com · wt'*},tq* lill request for proposal for selection of master system integrator for implementation of integrated command & control center and e-governance

::!. : .l::.::i I :ii.. Fi'-:

RFp for selection of MSI for implementation of lccc and e-Gov based smart city solution at Aligarh smart city

encryption with them.

t4

The prop""ed b.ck,p soft*are strould be able to recreate backed up data

from existing volumes from metadata backups. The solution should offer

recovery of specific volumes for recovery from metadata in case of a disaster

recovery.

15

ould have the capability for Block based

backups with granular recovery capability for Windows, Linux, Hyper-V'

VMWARE and Exchange for faster backups on suppoft

T6provide search capability from a web

portal to allow search for a single file frqm complete backup

17

Th" sol,rtio" shorld be capable of integration with active directory

infrastructure for ease of user rights management along with role based

access control to regulate the level of management

Page 5 of 10Addendum

-ffi ,l^ -!p-e--

Page 5: wT'* lill - smartcityaligarh.com · wt'*},tq* lill request for proposal for selection of master system integrator for implementation of integrated command & control center and e-governance

--_I

&.-'F!i€

RFP for Selection of MSI for implementation of ICCC and e-Gov based Smart City solution at Aligarh - --,

- Smart Clty

AnnexureB.59. HyperConvergedlnfrastructure

1.

The HCI solution should be proposed with minimum 2 nos. latest Intel Xeonprocessors of minimum 2.0 GHz or more (20 M cache or above) with minimum1-6 core per processor or more and 256 GB RAM with each node. The proposedsolution should provide a minimum of 150T8 of usable storage withoutconsidering de-duplication or compression. Bidder may increase the additionalstorase for successful solution deplovment.

2 Proposed solution should support minimum 8 nodes or higher in a single cluster

3

Proposed solution should support heterogeneous platforms that include ESXI/Hyper V and next generation containers either independently or concurrentlyon the same cluster

4The solution should provide software based storage services on serverhardware available from leading server vendors in the industry. lt shouldsupport all flash configurations on the server

5The proposed solution must have capability to support nodes withsame/different CPU & Memory configurations in the same cluster.

6

The proposed solution independently scale storage and compute as and whenneeded without any downtime. HClshould supportstorage expansion and compute expansion to extend storage/compute capacityas and when needed without extra cost for licenses

7 Hardware and Software support to be from the same, single OEM

8Solution should provide the flexibility to either combine the compute andstorage functions on the same hardware. lrrespective of the mode ofdeployment, the cluster should be managed using a single GUI

9Proposed solution should ensure best performance by leveraging all the drivesin the cf uste r tsr l/O and not depend on the locality of data

10Proposed solution should optimize the storage capacity consumption withoutcreating independent workload islands within a single cluster

tIA copy of the data is to be maintained at alltimes within a cluster anddistributed in such a way that the cluster can withstand a disk drive or a nodefailure

T2ln the event of a node/disk failure, the system should initiate copy creation ofdata in the free space without requiring a spare node/disk

13Proposed HCI solution should support fault tolerance of at least two nodesfailure within a cluster

Addendum Page 6 of 10

-n 1^ | rr-

Page 6: wT'* lill - smartcityaligarh.com · wt'*},tq* lill request for proposal for selection of master system integrator for implementation of integrated command & control center and e-governance

:E!: ! :ii:ri!: ! lifo

RFP for Selection of MSI for implementation of ICCC and e-Gov based Smart City solution at Aligarh - " :- Smart City

'J.4

HCI solution should provide the ability to expand to new, virtualized/non-virtualized/physical workloads with iSCSI/ NFS/ FCPISMB access without theneed of any additional license or cost.

15

HCI solution should include bare metal hypervisor with functionality of high

availability, zero downtime & zero data-loss without, live migration, dynamic

resource scheduling, hot add (CPU, Memory, Storage & Network)

t6

HCI solution should provide secure boot or equivalent for protection for both

the hypervisor and guest operating system by ensuring images have not been

tampered with and preventing loading of unauthorized components

L7

Hypervisor should have inbuilt distributed switch to centralize networkprovisioning, administration and monitoring using data center-wide networkaggregation, should provide network QoS to define priority access to networkresources

18

HCI solution should use VM based replication to asynchronously replicate VMs

across both the traditional and hyper converged sites based on configurable

schedules.

19

HCI solution should provide monitoring and management of virtualizedinfrastructure with configurable, customizable operations dashboards toprovide real-time insight into infrastructure behavior, and for capacity analytics.

it should provide also provide infrastructure and operations analytics toeliminate time-consuming problem resolution processes through automatedroot cause analysis.

zv

HCI solution should have network and security solution which should offervirtualized workload at the VNIC level to be protected with a statefull firewallengine based on constructs such as Mac , lP ports, objects and tags , active

directory groups, security groups etc. and the security policies must follow theVM in the event of migration (i.e. vMotion) within the data center

21,

Network and security solution must provide the NAT function for multitenantdeployment , distributed in-kernel routing with support of routing protocols like

OSPF and BGP as well as it should support SSL VPN capabilities in the virtualenvironment

22

Network and security solution should be embedded in the kernelof the host

architecture to protect east-west traffic by leveraging VM - based attributes like

VM names , Security tags, OS type, logical switches etc.

Addendum

\/]

Page 7 of L0

lnr\(^Y)A t P^-

Page 7: wT'* lill - smartcityaligarh.com · wt'*},tq* lill request for proposal for selection of master system integrator for implementation of integrated command & control center and e-governance

iir,: .#!.E;: iE.

RFP for Selection of MSI for implementation of ICCC and e-Gov based Smart City solution at Aligarh ^ ". ' -- Smart City

Annexure 8.60. Non-HClServer

LChipset Latest lntel Chipset supporting below Processors

Graphics integrated with chiPset

2 Form Factor Max. 2U rack mounted with sliding rails

3

Configured CPU Upto 2 nos. latest Xeon lntel processors ofminimum 2.4GHz or more with minimum 8 core

per processor or more

4Memory corifiguled Min. 128 GB DDR4 2133 MHz or above Memory

modules, scalable to 768 GB

5

Disks supported Minimum 2 x 600GB SFF 15K RPM, 6Gbps SAS

HDD / SSD Hot Pluggable Hard Drive with min 1

TB usable space. The server should supportSAS, SATA and SSD hard disk drives

5 RAID Controller Support RAID 1,5,57 DVD writer DVD RW

8

l/O slots Minimum 4 PCI-e (Express)slots in which

minimum 2 x PCI-e 8Xslots

Min 2 x USB 2.0, 1x Management port, 1x VGA

9GPU Support Should support required no. of graphics card as

oer bidder's solution

10 Network ports 4 x 1G and 2 x 10G Ports

LIOS Support Microsoft Windows Server, Hyper-V, VMWare,

Red Hat Enterprise Linux (RHEL), SUSE Linux

Enterprise Server (SLES)

L2 Power Supplv Redundant Power Supplv

13Management integration Support for integration with Microsoft System

Center, VMware vCenter, BMC Software-

L4

Pre-failure alert Should provide predictive failure monitoring &proactive alerts of actual or impending

component failure for fan, power supply,

memory, CPU, RAID, NlC, HDD

Page B of 10Addendum

,#,*&h

Page 8: wT'* lill - smartcityaligarh.com · wt'*},tq* lill request for proposal for selection of master system integrator for implementation of integrated command & control center and e-governance

!i:.t.#.*: i :iil.:

RFp for Selection of MSI for implementation of ICCC and e-Gov based Smart City solution at Aligarh- Smart City

Annexure 8.51. Opticat Fiber Cables (OFC) - 24148 Core

t Single Mode Optical Fiber ITU-T-G.652D

2Maximum Cabled Fiber Attenuationdb/Km' 1310nm:0.34 and 1550nm:0.20

3 Tensile Strength >2500N

4 Crush Resistadce >3000N

5Fiber Polarization Mode Dispersion(PMD)

<0.2 ps/Vkm

6 Operating Temperature A -200C to 700C

-f Color Coding of Tubes and Fibers ErA/TrA-598

8

ArmouringType : ECCS tape Tape thickness : >=

0.14mm

Outer Jacket Thickness)1.5mm

Water Tightness ErA/TrA-455-818

Minimum Continuous Length ZkmllOo/o,

Cable Design Life More than 15 Years

Material UsedThe optical fiber cable shall be made

of Germanium doped silica glass orpure silica glass.

Addendum Page 9 of 10

1n ,il^*'\t-,.-_

Page 9: wT'* lill - smartcityaligarh.com · wt'*},tq* lill request for proposal for selection of master system integrator for implementation of integrated command & control center and e-governance

RFP for Selection of MSI for implementation of ICCC and e-Gov based Smart City solution at Aligarh

lit . .=.#: sil.:' i rk

Smart City

Annexure 8.62. Pole

Addendum

. \n.l

Page 10 of 10

GeneralRequirement

Shallbe minimum 6.5m height as per NHAI norms

Hot dip galvanized pole with silver coating of 86 micronas per 15:2629 min 10 cm diameter pole and suitablebottom and top thick HT plate along with base plate size30x30xL5 cms suitable for wind speed 50 m/sec with suitablearm bracket and with J type foundation bolts. Fabrication inaccordance with lS 2713 nPole would be fixed on an adequate and strong foundation towithstand city weather conditions and wind speed of 150km/hrCasting of civil foundation with foundation bolts to ensurevibration free (video feed quality should not be impacted dueto wind in different climatic conditions) Expected foundationdepth of minimum 100 cms or better

Sign Board withnumber plate

Sign board depicting the area under surveillance andwith serial number of pole

Height of the pole shall be as per requirement of thelocation varying from 5 m to 12/15 m.

Lighting arrestors with proper grounding

Pole should have proper earthing system

A,oL I /)*-


Recommended