6
FluiDyne VHO/VQ Cartridge Kits Complete Pumps w w w. FluiDyneFP.com • A technically advanced manufacturing facility. • ISO Certified twelve production test stands – products are 100% tested prior to shipment. • 18 month warranty on all products. • Proprietary computer system to support customer service. • 95% same or next day delivery. Our People Make the Difference!
Transcript
Page 1: www. FluiDyneFP · @ 1200 RPM, 100 PSI 25V (Q) 10 GPM ... PVT, PVS VPV RACINE/BOSCH REXROTH A10V(S)018 A10V(S)028, 45, 71, 100 ... Schroeder Vicker Parker D0 …

FluiDyne VHO/VQCartridge KitsComplete Pumps

www . FluiDyneFP.com

• A technically advanced manufacturing facility.

• ISO Certified twelve production test stands –products are 100% tested prior to shipment.

• 18 month warranty on all products.

• Proprietary computer system to support customer service.

• 95% same or next day delivery.

Our People Make the Difference!

Page 2: www. FluiDyneFP · @ 1200 RPM, 100 PSI 25V (Q) 10 GPM ... PVT, PVS VPV RACINE/BOSCH REXROTH A10V(S)018 A10V(S)028, 45, 71, 100 ... Schroeder Vicker Parker D0 …

V i s i tw w w . F l u i D y n e F P. c o m

Em a i l : c s @ F l u i D y n e F P. c o m

• New application component selection

• Same day shipment

• 18 month warranty

• Advise on component repair and assembly

• Component failure analysis

• Massive local stock

Our people provide extensive support:

Our Promise: People Make the Difference

• Engineering expertise

• Decoding special part number

• Identification of parts within units

Our people provide extensive support:

FluiDyne supports the distributors providing local knowledge and assistance to fluid power customers.

Page 3: www. FluiDyneFP · @ 1200 RPM, 100 PSI 25V (Q) 10 GPM ... PVT, PVS VPV RACINE/BOSCH REXROTH A10V(S)018 A10V(S)028, 45, 71, 100 ... Schroeder Vicker Parker D0 …

SAMPLE CODE:

Single Pump Model Code

TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7

25V(Q) 21 A 1 C 22 L

Series Designation25V (Q)35V (Q)45V (Q)

Table 1

--- Rated Capacity @ 1200 RPM, 100 PSI25V (Q)10 GPM (38 l/min.)12 GPM (45 l/min.)14 GPM (53l/min.)17 GPM (64 l/min.)21 GPM (79 l/min.)35V (Q)25 GPM (94 l/min.)30 GPM (113 l/min.)35 GPM (132 l/min.)38 GPM (143 l/min.)45V (Q)42 GPM (158 l/min.)50 GPM (189 l/min.)60 GPM (226 l/min.)

Table 2 Shaft Type*1- Straight Keyed (Standard)86- H.D. Straight Key11- SAE Splined

Table 4

Outlet PositionA – Outlet Opposite from InletB – Outlet 90 Counter Clockwise from InletC – Outlet in line with InletD – Outlet 90 Clockwise from Inlet

Table 5

Design Series Number

Table 6

Rotation (Viewed from shaft end)L- Left Hand RotationR- Right Hand Rotation (or omit)

Table 7

Port ConnectionsA-SAE 4 Bolt

Table 3

FluiDyne Fluid Power stock completecartridge kits, and/or seals, rotors,cam rings, valve plates, shafts,mountings, and housings for all sizesand configurations. In single, double,triple combinations. FluiDyne canconvert Caterpillar pump numbers toremanufactured Vickers or GenuineFluiDyne products. Extensive stockand support where and when youneed it.

Page 4: www. FluiDyneFP · @ 1200 RPM, 100 PSI 25V (Q) 10 GPM ... PVT, PVS VPV RACINE/BOSCH REXROTH A10V(S)018 A10V(S)028, 45, 71, 100 ... Schroeder Vicker Parker D0 …

SAMPLE CODE:

Double Pump Model Code

TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7 TABLE 8

2520V(Q) 12 A 11 1 CC 22 L

Series Designation2520V (Q) 4520V (Q)3520V (Q) 4525V (Q)3525V (Q) 4535V (Q)

Table 1

Shaft End Pump Capacity Rated Capacity@ 1200 RPM, 100 PSI25V (Q)10 GPM (38 l/min.)12 GPM (45 l/min.)14 GPM (53 l/min.)17 GPM (64 l/min.)21 GPM (79 l/min.)35V (Q)25 GPM (94 l/min.)30 GPM (113 l/min.)35 GPM (132 l/min.)38 GPM (143 l/min.)

45V (Q)42 GPM (158 l/min.)50 GPM (189 l/min.)60 GPM (226 l/min.)

Table 2

Cover End Capacity @ 1200 RPM, 100 PSI**20V (Q) 2 GPM (7.6 l/min.)5 GPM (18.9 l/min.)8 GPM (30.2 l/min.)9 GPM (34 l/min.)11 GPM (41.5 l/min.)12 GPM (45 l/min.)14 GPM (53 l/min.)**25V (Q)12 GPM (45 l/min.)14 GPM (53 l/min.)17 GPM (64 l/min.)21 GPM (79 l/min.)

**35V (Q)25 GPM (94 l/min.)30 GPM (113 l/min.)35 GPM (132 l/min.)38 GPM (143 l/min.)

Table 4

Shaft Type (Single shaft seal pumps)*1- Straight Keyed (Standard)86- H.D. Straight Key11- SAE Splined

Table 5

Outlet Positions (Viewed from cover end of pump)

All series except 4535VWith No. 1 Outlet Opposite InletAA-No. 2 Outlet 135 CCW from InletAB-No.2 Outlet 45 CCW from InletAC-No.2 Outlet 45 CW from InletAD-No. 2 Outlet 135 CW from InletWith No. 1 Outlet 90 CCW from Inlet:BA-No.2 Outlet 135 CCW from InletBB-No.2 Outlet 45 CCW from InletBC-No.2 Outlet 45 CW from InletBD-No.2 Outlet 135 CW from InletWith No.1 Outlet inline with Inlet:CA-No.2 Outlet 135 CCW from InletCB-No.2 Outlet 45 CCW from InletCC-No.2 Outlet 45 CW from InletCD-No.2 Outlet 135 CW from InletWith No. 1 Outlet 90 CW from Inlet:DA-No.2 Outlet 135 CCW from InletDB-No.2 Outlet 45 CCW from InletDC-No.2 Outlet 45 CW from InletDD-No.2 Outlet 135 CW from InletSeries 4535VWith No. 1 Outlet Opposite InletAA-No.2 Outlet Opposite InletAB-No.2 Outlet 90 CCW from InletAC-No.2 Outlet Inline with InletAD-No.2 Outlet 90 CW from InletWith No. 1 Outlet 90 CCW from Inlet:BA-No.2 Outlet Opposite InletBB-No.2 Outlet 90 CCW from InletCC-No.2 Outlet Inline with InletDD-No.2 Outlet 90 CW from InletWith No.1 Outlet inline with Inlet:CA-No.2 Outlet Opposite InletCB-No.2 Outlet 90 CCW from InletCC-No.2 Outlet Inline with InletCD-No.2 Outlet 90 CW from InletWith No. 1 Outlet 90 CW from Inlet:DA-No.2 Outlet Opposite InletDB-No.2 Outlet 90 CCW from InletDC-No.2 Outlet Inline with InletDD-No.2 Outlet 90 CW from Inl

Table 6Design Series Number

Table 7

Rotation (Viewed from shaft end)L- Left Hand RotationR-Right Hand Rotation

(or omit)

Table 8

Table 3 SAE Port Connections

Code Inlet Out. #1 Out # 2 PumpShaft End Cover End Series

A 4-bolt Flg. 4-bolt flg. 4-bolt flg. All

C 4-bolt flg. SAE St. Thd. SAE St. Thd. 2520E 4-bolt flg. 4-bolt flg. SAE St. Thd. All except

4535

OUR PEOPLE

MAKE THE DIFFERENCE

OUR PEOPLE

MAKE THE DIFFERENCE

Page 5: www. FluiDyneFP · @ 1200 RPM, 100 PSI 25V (Q) 10 GPM ... PVT, PVS VPV RACINE/BOSCH REXROTH A10V(S)018 A10V(S)028, 45, 71, 100 ... Schroeder Vicker Parker D0 …

VHO / VQ Cart Kits

VHO / VQ Single, Double & Triple Pumps

30/35 Series35V2535V3035V3535V38

45 Series45V4245V5045V60

Industrial

20/25 Series20V0520V0820V1120V1220V1425V1225V1425V1725V21

30/35 Series30VQ2430VQ2835VQ2135VQ2535VQ3035VQ3535VQ38

45 Series45VQ4245VQ5045VQ6045VQ57

Mobile

20/25 Series20VQ0520VQ0820VQ1120VQ1220VQ1425VQ1225VQ1425VQ1925VQ21

Conversion capabilities available for many model types!

Sizes Available:FluiDyne New & Reman.• 20, 25, 30, 35, 45, 50 (V / VQ)

• 2520, 3520, 3525, 4520, 4525, 4535 (V / VQ)

Caterpillar Conversions

We can convert caterpillar pump numbers to remanufactured Vickers or Genuine FluiDyne products!

586.296.7200 • www.FluiDyneFP.com

Same Day Shipments

Supporting the channelsmeans shipping our high quality products to

the distributors and repair shops which provide local knowledge and assistance to the users

and builders of fluid power equipment.

Page 6: www. FluiDyneFP · @ 1200 RPM, 100 PSI 25V (Q) 10 GPM ... PVT, PVS VPV RACINE/BOSCH REXROTH A10V(S)018 A10V(S)028, 45, 71, 100 ... Schroeder Vicker Parker D0 …

PUMPS & MOTORS

VALVES

*Manufacturers names and numbers are for reference only

Square PumpsV10F, V10NF, V10P, V20F, V20NF, V20P

V10, V20, V2010, V2020

VHO / VQ Single, Double & Triple20, 25, 30, 35, 40, 45 (V/VQ)

2520, 2521, 3520, 3525, 4520, 4525, 4535 (V/VQ)

Cart Kits available for all sizes

*Caterpillar part numbered pumps also available

Round PumpsV104/5, V108/9, V110/1, V124/5, V128/9, V134/5

V144/5, V148/9, V350/3/6, V360/1/2, V368/9/70

VC108, 138, 148 Combination Pumps

VICKERS / EATON

Piston PumpsPVH 57, 74, 98, 131, 141

PVE 12, 19, 21, 27, 35, 47, 62

MotorsMHT 32, 50, 70, 90, 150, 250, 330, 440500, 660, 750, 1000

25M, 26M, 35M, 36M, 45M, 46M, 50M

M2-210

TransmissionsTA15, 19, 1919, 19V, 21

PSV 10, 15, 20, 25, 40

PSV 80, 100

PVF, PVQ, PVR

PVK, PVT, PVS

VPV

RACINE/BOSCH

REXROTHA10V(S)018

A10V(S)028, 45, 71, 100, 140

A4V(S)071, 125, 180, 250

DENISON

OILGEARPVW (W) (H) 06, 10, 15, 20, 34, 45, 60

Single T6, T7

Double T6, T67, T7

Triple T6, T67, T7

PV6, 10, 15, 20, 29

M4C, M4D, M4E

VELJANSingle VT6, VT7

Double VT6, VT67, VT7

Triple VT6, VT67, VT7

Drive Train VT6*R

VM4C, VM4D, VM4E

VM3B

CHAR-LYNNH SERIES (101-)

S SERIES (103-)

2000, 4000 (104-, 109-)

6000, 10,000 (112-, 119-)

J SERIES (129-)

DUMP PUMPSC101/102

EATONSAUER- DANFOSSWHITEPARKER/ROSS/TRW

INTERCHANGES WITH:

FluiDyne Remanufactured products Aftermarket Veljan

CG5

4CT, 4CG

DT8P1

Relief Valves

Check Valves

CT/CG/CS/CF 03, 06, 10Directional Valves

1/8 thru 1-1/2Needle Valves

X (C) G OR T 03, 06, 10Pressure Controls

Stack ModulesDGM Staks, Flow Control, Reliefs, Checks, Pressure Controls

FILTERS

FluiDyne has a full range of replacement filters elements and filter housings for:

Pall Hydac HyconSchroeder Vicker Parker

D03 – DG4V3, 4WE6

D05 – DG4S401, 4WE10

DG5V5, DG5S4, 4WEH10, 4WEH16

D08 - DG5S4, DG5S8, 4WEH25

DG17S/V 03, 05

DO3-5-7-8Valves and Stacks

31915 Groesbeck Highway • Fraser, Michigan 48026PH: 1-586-296-7200 • FAX: 1-586-296-7210 www.FluiDyneFP.com • Email: [email protected]

A n I S O 9 0 0 1 : 2 0 0 8 C o m p a n y6/2012


Recommended