2
Product photo/image above may show some available options Whitehall Mfg. > P.O. Box 3527 > City of Industry, CA 91744 > (800) 782-7706 > (626) 968-6681 > FAX (626) 855-4862 DT X-Ray Developing Tanks Models DT-2, DT-3 & DT-5 Shown from Left to Right: Model DT-2 & DT-5 X-Ray Developing Tanks X-ray Developing Tanks are used in the medical facili- ty in the process of developing x-ray film. The master (external) tank is fabricated from heavy gauge type 316 stainless steel. The legs, of type 304 stainless steel, is welded and pol- ished to a satin finish. Insert tanks are suspended on racks inside the master developing tank, allowing full circulation of water around the sides and bottom. These insert tanks are secured by stainless steel tabs to prevent floating while filling the tank and are removable for cleaning. Direct connections to the water supply and drain allows for a constant flow of fresh water, providing a clean- er wash area and better control of temperature. The tank is equiped with PVC fittings for inlet, drain and overflow con- nections. The overflow pipe maintains excess water and inhibits surface scum formation. Model DT-2 is recommended for podiatry practices. The master tank is 16"L x 13"W x 17-1/2"D. The master tank has a two gallon capacity. Two insert tanks accommodate hangers up to and including 10" x 12". Model DT-3 is also recommended for podiatry practices. The master tank is also 16"L x 13"W x 17-1/2"D. The mas- ter tank has the capacity of three gallons. Two insert tanks accommodate hangers up to and including 10" x 12". Model DT-5 is suggested for larger medical facilities. The master tank is 19-1/2"L x 16-1/2"W x 22-1/2"D. The tank is capable of holding 5 gallons. Two insert tanks accommo- date hangers up to and including 14" x 17". SPECIFICATION GUIDELINES Three models are available. Each model listed below includes as standard a developing tank with legs, two removable insert tanks, inlet fitting and combination drain and overflow assembly. Last Update: 1/1/05
Transcript
Page 1: X-Ray Developing Tanks

Product photo/image above may show some available options

Whitehall Mfg. > P.O. Box 3527 > City of Industry, CA 91744 > (800) 782-7706 > (626) 968-6681 > FAX (626) 855-4862

DT

X-RayDeveloping Tanks

Models DT-2, DT-3 & DT-5Shown from Left to Right:

Model DT-2 & DT-5

X-Ray Developing Tanks

X-ray Developing Tanks are used in the medical facili-ty in the process of developing x-ray film.

The master (external) tank is fabricated from heavygauge type 316 stainless steel.

The legs, of type 304 stainless steel, is welded and pol-ished to a satin finish.

Insert tanks are suspended on racks inside the masterdeveloping tank, allowing full circulation of water aroundthe sides and bottom. These insert tanks are secured bystainless steel tabs to prevent floating while filling the tankand are removable for cleaning.

Direct connections to the water supply and drainallows for a constant flow of fresh water, providing a clean-er wash area and better control of temperature. The tank isequiped with PVC fittings for inlet, drain and overflow con-nections. The overflow pipe maintains excess water andinhibits surface scum formation.

Model DT-2 is recommended for podiatry practices. Themaster tank is 16"L x 13"W x 17-1/2"D. The master tankhas a two gallon capacity. Two insert tanks accommodatehangers up to and including 10" x 12".

Model DT-3 is also recommended for podiatry practices.The master tank is also 16"L x 13"W x 17-1/2"D. The mas-ter tank has the capacity of three gallons. Two insert tanksaccommodate hangers up to and including 10" x 12".

Model DT-5 is suggested for larger medical facilities. Themaster tank is 19-1/2"L x 16-1/2"W x 22-1/2"D. The tankis capable of holding 5 gallons. Two insert tanks accommo-date hangers up to and including 14" x 17".

SPECIFICATION GUIDELINES

Three models are available. Each model listed belowincludes as standard a developing tank with legs, tworemovable insert tanks, inlet fitting and combination drainand overflow assembly.

Last Update: 1/1/05

Page 2: X-Ray Developing Tanks

MODEL NUMBER AND OPTION SELECTIONS

Whitehall Mfg. > P.O. Box 3527 > City of Industry, CA 91744 > (800) 782-7706 > (626) 968-6681 > FAX (626) 855-4862

X-Ray Developing Tanks

All dimensions are nominal and subject to manufacturer’schange without notice. Whitehall assumes no responsibilityfor use of void or suspended data. © 2005 WhitehallManufacturing, A Division of Acorn Engineering Company.Please visit www.whitehallmfg.com for most current specifications.

Model Number & Options_____________________________________________ Quantity_____________Company_________________________________________________________ Date___________________Contact________________________________________________ Title______________________________Approval for Manufacturing/Signature_______________________________________________________

SELECTION SUMMARY & APPROVAL FOR MANUFACTURING

Seriesm DT X-Ray Developing Tanks

Capacitym -2 2 gallons (holds up to 10" x 12" hangers)m -3 3 gallons (holds up to 10" x 12" hangers)m -5 5 gallons (holds up to 14" x 17" hangers)

Suffix Optionsm -DTC-2 Master Tank Cover (for DT-2 or DT-3)m -DTC-5 Master Tank Cover (for DT-5)m -DR-1 Film Drying Rack

m -IC-2 Insert Cover (for DT-2 only)m -IC-3 Insert Cover (for DT-3 only)m -IC-5 Insert Cover (for DT-5 only)

m -IT-2 Insert Tank (for DT-2 only)m -IT-3 Insert Tank (for DT-3 only)m -IT-5 Insert Tank (for DT-5 only)

DT Last Update: 1/1/05

All dimension figuresin parentheses are in millimeters.


Recommended