+ All Categories
Home > Self Improvement > Xceed (kkh 2011)

Xceed (kkh 2011)

Date post: 17-Nov-2014
Category:
Upload: amakusa2001
View: 431 times
Download: 3 times
Share this document with a friend
Description:
 
Popular Tags:
23
Optium Xceed Training Patrick Ho Account Executive
Transcript
Page 1: Xceed (kkh 2011)

Optium Xceed Training

Patrick Ho

Account Executive

Page 2: Xceed (kkh 2011)

Xceed meter13/01/2009

2 Company Confidential© 2009 Abbott

Diabetes and Weight Management18th Oct 2008

2Company Confidential© 2008 Abbott

Page 3: Xceed (kkh 2011)

Xceed meter13/01/2009

3 Company Confidential© 2009 Abbott

Xceed Meter

Page 4: Xceed (kkh 2011)

Setting of Xceed™ Meter

Page 5: Xceed (kkh 2011)

Xceed meter13/01/2009

5 Company Confidential© 2009 Abbott

Setting of time and date

Page 6: Xceed (kkh 2011)

Xceed meter13/01/2009

6 Company Confidential© 2009 Abbott

Page 7: Xceed (kkh 2011)

Xceed meter13/01/2009

7 Company Confidential© 2009 Abbott

Page 8: Xceed (kkh 2011)

Xceed meter13/01/2009

8 Company Confidential© 2009 Abbott

Page 9: Xceed (kkh 2011)

Xceed meter13/01/2009

9 Company Confidential© 2009 Abbott

Page 10: Xceed (kkh 2011)

Xceed meter13/01/2009

10 Company Confidential© 2009 Abbott

Page 11: Xceed (kkh 2011)

Xceed meter13/01/2009

11 Company Confidential© 2009 Abbott

Page 12: Xceed (kkh 2011)

Xceed meter13/01/2009

12 Company Confidential© 2009 Abbott

Page 13: Xceed (kkh 2011)

Usage of Xceed™ Meter

Page 14: Xceed (kkh 2011)

Xceed meter13/01/2009

14 Company Confidential© 2009 Abbott

Page 15: Xceed (kkh 2011)

Xceed meter13/01/2009

15 Company Confidential© 2009 Abbott

Calibration

• Insert Calibrator• Meter will switch on automatically

• Wait for the meter to be calibrated

• Remove calibrator and calibration is done

Page 16: Xceed (kkh 2011)

Xceed meter13/01/2009

16 Company Confidential© 2009 Abbott

Usage of test strip

• Hold on to the strip

•Open the Test Strip by tearing at the side of the foil

•Insert the test strip into the meter

Page 17: Xceed (kkh 2011)

Xceed meter13/01/2009

17 Company Confidential© 2009 Abbott

Blood Sample Collection

• Use Abbott Single Fire Lancing Device

• Clean with Alcohol Swap• Await site to be dry

• Warm and rub the site• Let the arm hang down for punctures on the hand

• Use side of the finger. Avoid pricking at the finger tip• Clean the first drop of blood sample

• Apply to test strip immediately• Squeeze gently for the second drop of blood

Page 18: Xceed (kkh 2011)

Better Control of Blood Glucose

Page 19: Xceed (kkh 2011)

Xceed meter13/01/2009

19 Company Confidential© 2009 Abbott

Diabetes and Weight Management18th Oct 2008

19Company Confidential© 2008 Abbott

Optimal HBA1C for Diabetic Patients

6.5% – 7.0%

Page 20: Xceed (kkh 2011)

Xceed meter13/01/2009

20 Company Confidential© 2009 Abbott

Diabetes and Weight Management18th Oct 2008

20Company Confidential© 2008 Abbott

Useful Tool – Self Glucose Monitoring Log Book

Page 21: Xceed (kkh 2011)

Xceed meter13/01/2009

21 Company Confidential© 2009 Abbott

Diabetes and Weight Management18th Oct 2008

21Company Confidential© 2008 Abbott

Glucose meter: Test at least 3 - 6 times a week

• Aim for testing at least 3 - 6 times a week

• Pre-meal glucose at 6.1mmol/l to 8.0mmol/l

• 2 hrs post meal glucose at 7.1mmol/l to 10.0mmol/l

Page 22: Xceed (kkh 2011)

Best Solution

Mondays to Fridays 8 30am – 5 30pm

1800-272-2881

Patrick Ho (SRN)

Account Executive

81110018

Page 23: Xceed (kkh 2011)

Recommended