    Safety detection solutions 3Guard switches, actuator operatedMetal, turret head, types XCS A, XCS and XCS CPlastic, double insulated, turret head,types XCS MP or XCS PA and XCS TA

    Metal, types XCS A, XCS B,

    XCS C

    Guard switches with or without locking of the actuator

    Page 1/202

    Plastic, types XCS MP, XCS PAXCS TA

    Guard switches with or without locking of the actuator

    Pages 1/206 and1/210

    Presentation,characteristics

    Environment characteristicsGuard switch type XCS A, XCS B, XCS C

    (metal)XCS MP, XCS PA, XCS TA(plastic)

    Conformity to standards Products EN/IEC 60947-5-1, UL 508, CSA C22-2 n 14

    Machine assemblies EN/IEC 60204-1, EN/ISO 14119

    Product certifcations UL, CSA UL, CSA (cULus for XCS MP)

    Maximum safety level (1) PL=e, Category 4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508

    Reliability data B10d 5 000 000 (data value for a service life of 10 years can be limited by contact and mechanical wear)

    Protective treatment Standard version: TC

    Ambient air temperature For operation - 25+ 70C

    For storage - 40+ 70C (- 25+ 80C for XCS MP)

    Vibration resistance 5 gn (10500 Hz) conforming to EN/IEC 60068-2-6 (6 gn (1055 Hz) for XCS MP)

    Shock resistance 10 gn (duration 11 ms) conforming to EN/IEC 60068-2-27 (50 gn (duration 11 ms) for XCS MP)

    Electric shock protection Class 1 conforming to EN/IEC 60536 Class 2 conforming to EN/IEC 60536

    Degree of protection IP 67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1(2)

    Cable entry 1 entry tapped ISO M20 x 1.5 (clampingcapacity 7 to 13 mm) or tapped for n 13(Pg 13.5) cable gland conforming toNFC 68-300 (clamping capacity 9 to 12 mm)or for 1/2" NPT (USAS B2-1) conduit

    1 entry (XCS PA) or 2 entries (XCS TA) tappedfor ISO M16 x 1.5 cable gland (clampingcapacity 4.5 to 10 mm) or for n 11 (Pg 11)cable gland, or tapped 1/2" NPT, or for 1/2"NPT (USAS B2-1) conduit using metal adaptorDE9 RA1012) for XCS TA(other entry ttedwith blanking plug).

    Connecting cable Pre-cabled, either 4 x 0.5 mm2or 6 x 0.5 mm2(XCS MP)

    Materials XCS A/B/CZamak case

    XCS MP/PA/TAPolyamide PA66 breglass impregnated case

    Actuators (all types): steel XC60, surface treated

    (1) Using an appropriate and correctly connected control system.

    (2) Live parts of these switches are protected against the penetration of dust and water.

    However, when installing take all necessary precautions to prevent the penetration of solidbodies, or liquids with a high dust content, into the actuator aperture. Not recommended foruse in saline atmospheres.

    4

    5

    6

    0

  • 8/10/2019 xcsa

    3/271/201

    5

    Safety detection solutions 3Guard switches, actuator operatedMetal, turret head, types XCS A, XCS and XCS CPlastic, double insulated, turret head,types XCS MP or XCS PA and XCS TA

    Contact block characteristicsRated operationalcharacteristics

    2 and 3 contact, slow break XCS A, XCS B, XCS C,XCS TA,XCS PA:aAC-15, A300: Ue = 240 V, Ie = 3 A orUe = 120 V, Ie = 6 A

    XCS MP:aAC-15, C300: Ue = 240 V, Ie = 0.75 A or Ue = 120 V, Ie = 1.5 AAll models:cDC-13, Q300: Ue = 250 V, Ie = 0.27 A or Ue = 125 V, Ie = 0.55 Aconforming to EN/IEC 60947-5-1

    2 contact, snap action XCS PA:aAC-15, A300: Ue = 240 V, Ie = 3 A; Ithe = 10 AcDC-13, Q300: Ue = 250 V, Ie = 0.27 A or Ue = 125 V, Ie = 0.55 A conforming to EN/IEC 60947-5-1

    3 contact, snap action XCS PA:aAC-15, B300: Ue = 240 V, Ie = 1.5 A; Ithe = 6 AcDC-13, R300: Ue = 250 V, Ie = 0.1 A or Ue = 125 V, Ie = 0.55 A conforming to EN/IEC 60947-5-1

    Conventional thermal current in enclosure XCS A, XCS B, XCS C, XCS PA(2 & 3 slow break contact and 2 snap action contact versions)XCS PA (3 snap action contact version): Ithe = 6 AXCS MP: Ithe = 2.5 A

    Rated insulation voltage 2 and 3 contact 3 contact (XCS A, XCS B, XCS C, XCS TA), 2 contact (XCS PA),2 and 3 contact (XCS MP):Ui = 500 V conforming to EN/IEC 60947-1; Ui = 300 V conforming to UL 508, CSA C22-2 n 14

    3 contact XCS PA:Ui = 400 V degree of pollution 3 conforming to EN/IEC 60947-1

    Ui = 300 V conforming to UL 508, CSA C22-2 n 14Rated impulse withstandvoltage

    2 and 3 contact 3 contact (XCS A, XCS B, XCS C, XCS TA), 2 contact (XCS PA),2 and 3 contact (XCS MP): Uimp = 6 kV conforming to EN/IEC 60947-5-1

    3 contact XCS PA:Uimp = 4 kV conforming to EN/IEC 60947-5-4

    Positive operation NC contacts with positive opening operation conforming to EN/IEC 60947-5-1, Section 3

    Resistance across terminals y30 mWconforming to EN/IEC 60947-5-4

    Short-circuit protection 2 and 3 contact 3 contact (XCS A,XCS B,XCS C,XCS TA), 2 contact (XCS PA),2 and 3 contact (XCS MP): 10 A cartridge fuse type gG (gl)

    3 contact XCS PA:6 A cartridge fuse type gG (gl)

    Connection Pre-cabled 4 x 0.5 mm2or 6 x 0.5 mm2(XCS MP). PVC

    Screw clampterminals

    2 contact, snap action XCS PA, XCS TA:Clamping capacity, min: 1 x 0.34 mm2, max: 2 x 1.5 mm2

    2 and 3 contact 3 contact (XCS A, XCS B, XCS C, XCS TA), 2 contact (XCS PA):Clamping capacity, min: 1 x 0.5 mm2, max: 2 x 1.5 mm2with or without cable end

    3 contact XCS PA:clamping capacity, min: 1 x 0.34 mm2

    , max: 1 x 1 mm2

    or 2 x 0.75 mm2

    Electrical durability

    Conforming to EN/IEC 60947-5-1 Appendix C.Utilisation categories AC-15 and DC-13.Maximum operating rate: 3600 operating cycles/hour.Load factor: 0.5

    Only applicable to XCS MP: Conforming to EN/IEC 60947-5-1 Appendix C.Utilisation categories AC-15 and DC-13.Maximum operating rate: 900 operating cycles/hour.

    Characteristics (continued)

    2 snap action contact version 3 contact version XCS A/B/C/TAand 2 slow break contact version

    AC supply50/60 Hzaoinductive circuit

    Millionsofoperatingcycles

    Current in A

    0.1

    0.5

    1

    5

    0.5 1 5 10

    110 V

    48 V

    230/400 V

    2 3 4

    Ithe

    24 V

    DC supplycPower broken in W for5 million operating cycles.

    Voltage V 24 48 120 Voltage V 24 48 120o W 10 7 4 o W 13 9 7

    For XE2S Pp151 onaorc, NC and NO contacts simultaneously loaded to the values shown with reverse polarity.

    3 snap action contact version XCS PA 3 slow break contact version XCS PA

    AC supply50/60 Hzaoinductive circuit

    DC supplycPower broken in W for5 million operating cycles.

    Voltage V 24 48 120 Voltage V 24 48 120

    o W 3 2 1 o W 4 3 2

    Millionsofoperatingcycles

    Current in A

    0.5 1 2 3 4 5 100.1

    0.2

    0.5

    1

    5

    2

    43

    Ithe

    230 V 12/24/48 V

    110 V

    0.1

    0.5

    1

    5

    0.5 1 5 10

    110 V

    48 V

    230/400 V

    2 3 4

    24 V

    e

    Millionsofoperatingcycles

    Current in A

    Millionsofoperatingcycles

    Current in A

    0.5 1 2 3 4 5 100.1

    0.2

    0.5

    1

    5

    2

    43

    230 V110 V

    12/24/48 V

    Ithe

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • 8/10/2019 xcsa

    4/271/202

    5

    Safety detection solutions 0Guard switches, actuator operatedMetal, turret head(1), types XCS A, XCS B and XCS C1 cable entry

    Type of switch Without locking of actuator With locking of actuator, manual unlocking (2)

    LED indication on opening of NCcontacts

    Without 1 orangeLED24/48 Vz

    1 orangeLED110/240 Va

    Without 1 orangeLED24/48 Vz

    1 orangeLED110/240 Va

    Without 1 orangeLED24/48 Vz

    1 orangeLED110/240 Va

    References of switches without actuator ( NC contact with positive opening operation)

    with 1 cable entry tapped ISO M20 x 1.53-pole

    NC + NO + NO(2 NO staggered)slow break(3)

    33

    34

    22

    2

    113

    14

    XCS A502 XCS A512 XCS A522 XCS B502 XCS B512 XCS B522 XCS C502 XCS C512 XCS C522

    3-poleNC + NC + NO(NO staggered)slow break(3) 3

    2

    31

    13

    14

    22

    21 XCS A702 XCS A712 XCS A722 XCS B702 XCS B712 XCS B722 XCS C702 XCS C712 XCS C722

    3-poleNC + NC + NCslow break(3)

    12

    11

    22

    21

    32

    31 XCS A802 XCS B802 XCS C802

    Weight (kg) 0.440 0.440 0.440 0.475 0.475 0.475 0.480 0.480 0.480

    References of switches without actuator ( NC contact with positive opening operation)

    with 1 cable entry tapped Pg 13.5

    To order a switch with a Pg 13.5 cable entry, replace the last number (2) by 1in the selected reference.Example: XCS A502 becomes XCS A501.

    References of switches without actuator ( NC contact with positive opening operation)

    with 1 cable entry tapped 1/2" NPTTo order a switch with a 1/2" NPT cable entry, replace the last number (2) by 3in the selected reference.Example: XCS A502 becomes XCS A503.

    Complementary characteristics not shown under general characteristics (page 1/200)Actuation speed Maximum: 0.5 m/s, minimum: 0.01 m/s

    Resistance to forcible withdrawalof actuator

    XCS Band XCS C: 1500 N

    Mechanical durability XCS A: > 1 million operating cyclesXCS B and XCS C: 0.6 million operating cycles

    Maximum operating rate For maximum durability: 600 operating cycles per hour

    Minimum force for extraction of actuator u20 N

    Cable entry XCS A, XCS B, XCS C: 1 cable entryEntry tapped ISO M20 x 1.5, clamping capacity 7 to 13 mm

    Materials Body: zamak. Head: zamak. Safety screws: 5-lobe torque. Protective plate: steel.

    References of actuators

    Description Straight actuator Actuator with wide xing Pivoting actuator Latch for sliding doors

    For guard switches XCS A, B, C, E XCS Z01 XCS Z02 XCS Z03 XCS Z05

    Weight (kg) 0.020 0.020 0.095 0.600

    (1) Head adjustable in 90 steps throughout 360. Blanking plug for operating head slot included with switch.

    (2) Unlocking by pushbutton for XCS Bpppand by key operated lock for XCS Cppp(2 keys included with switch).

    (3) Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch.

    Other versions: please consult our Customer Care Centre.

    Dimensions:page 1/203

    Schemes:page 1/205

    References,characteristics

    4

    5

    6

    0

  • 8/10/2019 xcsa

    5/271/203

    5

    Separate componentsDescription For use

    withSupplyvoltage

    Reference Weightkg

    1 orange LEDindicator modulewith cover, seal and2 xing screws

    XCS AXCS BXCS C

    aor 24/48 Vc XCS Z31 0.040

    110/240 Va XCS Z32 0.040

    Description For use with Unit reference Weightkg

    Blanking plugs foroperating head slot(Sold in lots of 10)

    XCS A,XCS B,XCS C

    XCS Z27 0.050

    Keys for interlockforced openingdevice(Sold in lots of 10)

    XCS B,XCS C

    XCS Z25 0.100

    Padlocking deviceto prevent insertion ofactuator,for up to 3 padlocks(padlocks not included)

    XCS A,XCS B,XCS C

    XCS Z90 0.055

    DimensionsGuard switches

    XCS Appp XCS Bppp, XCS Cppp

    (1) 1 tapped entry for cable gland

    : 2 elongated holes 5.3 x 7.3

    (1) 1 tapped entry for cable gland

    : 2 elongated holes 5.3 x 7.3

    XCS Z90

    809850

    33

    60

    43.5

    1

    13.5

    40

    30= =

    38

    33

    16

    44

    (1)

    7

    5.3

    Safety detection solutions 0Guard switches, actuator operatedMetal, turret head, types XCS A, XCS B and XCS C1 cable entry

    References,dimensions

    XCS Z3p

    809847

    33

    60

    43.5

    113.5

    52

    28.5

    40

    30= =

    37

    16

    44

    38

    33

    (1)

    7

    5.3

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • 8/10/2019 xcsa

    6/271/204

    5

    Safety detection solutions 0Guard switches, actuator operatedMetal, turret head, types XCS A, XCS B and XCS C1 cable entry

    Dimensions (continued)

    Actuators

    XCS Z01 XCS Z02

    (1) Adaptor (included with actuator XCS Z01) for replacing, without drillingadditional xing hole, a guard switch XCK J with actuator ZCK Y07 bya guard switch XCS A, B, C or E with actuator XCS Z01.

    : 2 elongated holes 5.3 x 10 : 2 elongated holes 5.3 x 10

    XCS Z03 XCS Z05

    Fixing axis % related to actuator. : 4 elongated holes 5.3 x 7.3

    Operating radius required for actuator

    XCS Z01 XCS Z02

    XCS Z03

    R = minimum radius

    3

    =

    = 14

    35

    20 7.5

    2.5

    =

    = 15

    25

    81.5

    33 20 11

    Adaptor shank (1)

    11

    55.52.5

    51

    35

    =

    ==

    =

    25

    33

    2.5

    48

    76

    2.

    5

    11

    40

    17

    23

    33

    25

    30

    30

    2.5

    11

    30

    25

    5.3

    40

    11

    41

    3

    2

    140

    100 2020

    4xM5

    26

    7

    742

    12.5

    115 64

    20

    6

    6

    18

    R=2000

    85

    R=2000

    85

    R=2000

    58

    R=2000

    58

    R=15022

    55

    79

    R=400

    16.5

    79

    References:page 1/202

    Schemes:page 1/205

    4

    5

    6

    0

  • 8/10/2019 xcsa

    7/271/205

    5

    Safety detection solutions 0Guard switches, actuator operatedMetal, turret head, types XCS A, XCS B and XCS C1 cable entry

    Setting-up,schemes

    Setting-upFunctional diagrams

    XCSp

    5ppp

    XCSp

    7ppp

    XCSp

    8ppp

    Contact operation

    G Closed

    HOpen

    GUnstable

    Schemes Note: These schemes are given as examples only, the designer must refer to the relevant safety standards for guidance.Wiring to PL=b, category 1 conforming toEN/SO 13849-1

    Wiring to PL=d, category 3 conforming to EN/ISO 13849-1

    Example with 3-pole NC + NO + NO contact and protectionfuse to prevent shunting of the NC contact, either by cabledamage or by tampering.

    Example with 3-pole NC + NO + NO contact with mixed redundancy of the contacts and theassociated control relays. To activate K1, it is necessary to remove and re-insert the actuatorwhen the supply is switched on.

    (1) Signalling contact H1: actuator not inserted indicator

    Wiring to PL=e, category 4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508. Wiring method used in conjunction

    with Preventa safety module (The guard switch should be used in conjunction with a safety limit switch to give electrical/mechanical redundancy).

    Method for machines with quick rundown time (low inertia)

    Locking device based on the principle of redundancy and self-monitoring.The safety modules ensure these functions.

    Locking of actuator and operation in positive mode associatedwith a safety module.

    23

    21

    22.5

    25

    31

    21-22

    13-14

    33-34

    23

    21.5

    22

    25

    31

    21-22

    31-32

    13-14

    23

    25

    31

    11-12

    21-22

    31-32

    X

    F1

    O

    I

    X

    22

    21

    13

    14

    33

    34

    M

    (1)

    F1

    K2

    K1 K2

    14

    13

    34

    33

    22

    21

    K1

    K2

    K1

    KM1

    O

    I

    KM2

    H1

    K2

    K1

    KM1

    KM2

    M

    XPS

    References:page 1/202

    Dimensions:page 1/203

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • 8/10/2019 xcsa

    8/271/206

    5

    Safety detection solutions 2Guard switches, actuator operatedPlastic, xed head, type XCS MPPre-cabled, length 2 m, 5 m or 10 m

    Type of switch Without locking of actuator

    References of switches without actuator ( NC contact with positive opening operation)(1)2-pole NC + NObreak before make, slow break (2)

    XCS MP59Lp

    2-pole NC + NCslow break (2)

    XCS MP79Lp

    3-pole NC + NC + NO(NO staggered) slow break (2)

    XCS MP70Lp

    3-pole NC + NC+ NCslow break (2)

    XCS MP80Lp

    Weight (kg) 0.110

    Complementary characteristics not shown under general characteristics (page 1/200)Actuation speed Maximum: 1.5 m/s, minimum: 0.05 m/s

    Resistance to forcible withdrawal of actuator 8 N

    Mechanical durability > 1 million operating cycles

    Pre-cabled connection 4 x 0.5 mm2or 6 x 0.5 mm2

    Maximum operating rate For maximum durability: 1200 operating cycles per hour

    Minimum force for extraction of actuator u8 N

    References of actuatorsDescription Straight actuator Right-angled

    actuator

    Pivoting actuator

    For right-hand door For left-hand door

    For guard switches XCS MP XCS Z81 XCS Z84 XCS Z83 XCS Z85

    Weight (kg) 0.015 0.025 0.085 0.085

    Separate componentsDescription Unit reference Weight

    kg

    Blanking plugs for operating head slot(Sold in lots of 10)

    XCS Z29 0.005

    (1) Blanking plug for operating head slot included with switch (3). Basic reference, to be completed: replace the dot by 2 for a 2 m long cable, by 5 for a 5 m long

    cable or by 10 for a 10 m long cable. Example:XCS MP59LpbecomesXCS MP59L10 for a switch with a 10 m long cable.(2) Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch.

    OG

    OG/WH

    BU/WH

    BU

    BU/WH

    BU

    OG/WH

    OG

    OG

    OG/WH

    BU/WH

    BU

    BN/WH

    BN

    BU/WH

    BU

    BN/WH

    BN

    OG/WH

    OG

    Dimensions:page 1/207

    Schemes:page 1/209

    References,characteristics

    4

    5

    6

    0

  • 8/10/2019 xcsa

    9/271/207

    5

    Safety detection solutions 2Guard switches, actuator operatedPlastic, xed head, type XCS MPPre-cabled, length 2 m, 5 m or 10 m

    DimensionsXCS MP XCS Z81

    (1) 7.6, length 2, 5 or 10 m.

    XCS Z84

    XCS Z83

    (1) 2 elongated holes 4.2 x 6.

    XCS Z85

    (1) 2 elongated holes 4.2 x 6.

    20

    30

    (1)

    1 115

    58

    35

    78

    9

    4.4

    14

    5.

    6

    3.

    5

    14 13.5

    62

    28.235.9

    8.

    4

    2x4.32x9

    5

    33.8

    14

    3.

    5

    14

    11.

    6

    34

    8.4

    4.3

    25

    34

    =

    =

    =

    15

    =

    28.213

    8.

    4

    (1)

    3.

    5

    25

    34

    =

    =

    =

    15

    =

    28.213

    8.

    4

    (1)

    3.5

    Characteristics:page 1/200

    Dimensions

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • 8/10/2019 xcsa

    10/271/208

    5

    Safety detection solutions 2Guard switches, actuator operatedPlastic, xed head, type XCS MPPre-cabled, length 2 m, 5 m or 10 m

    Operating radius required for actuatorXCS Z81 XCS Z84

    XCS Z83 XCS Z85

    Functional diagramsXCS MP59p XCS MP79p XCS MP70p XCS MP80p

    Contact operation closed

    open

    R=930m

    m

    66.8

    R=160m

    m

    66.8

    R=230mm

    36.4

    R=16

    0mm

    36.4

    R=50m

    m

    43.8

    R=50m

    m

    43.8

    R=50mm

    43.8

    R=50mm

    43.8

    BU-BU/WH

    OG-OG/WH

    5.2

    5.5

    28.2

    5.2

    28.2

    BU-BU/WH

    OG-OG/WH

    BN-BN/WH

    OG-OG/WH

    BU-BU/WH

    5.2

    5.5

    28.2

    BN-BN/WHOG-OG/WH

    BU-BU/WH

    5.2

    28.2

    Setting-up,schemes

    4

    5

    6

    0

  • 8/10/2019 xcsa

    11/271/209

    5

    Safety detection solutions 2Guard switches, actuator operatedPlastic, xed head, type XCS MPPre-cabled, length 2 m, 5 m or 10 m

    Schemes Note: These schemes are given as examples only, the designer must refer to the relevant safety standards for guidance.Wiring to PL=b, category 1 conforming to

    EN/SO 13849-1

    Wiring to PL=d, category 3 conforming to EN/ISO 13849-1

    Example with 3-pole NC + NC + NO contact and protectionfuse to prevent shunting of the NC contact, either by cabledamage or by tampering.

    (1) Signalling contact

    Example with 2-pole NC + NO contact with mixed redundancy of the contacts and theassociated control relays.To activate K1, it is necessary to remove and re-insert the actuator when the supply is switched on.

    Wiring to PL=e, category 4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508. Wiring method used in conjunction

    with Preventa safety module (The guard switch should be used in conjunction with a safety limit switch to give electrical/mechanical redundancy).

    Method for machines with quick rundown time (low inertia)Locking or interlocking device based on the principle of redundancy and self-monitoring.The safety modules ensure these functions.

    Locking of actuator and operation in positive mode associated with a safety module

    K1

    F1

    (1)

    O

    I

    K1

    BU/WH

    BU

    BN

    BN/WH

    OG

    OG/WH

    M

    F1

    K2

    K1 K2

    OG/WH

    OG

    BU/WH

    BU

    K1

    K2

    K1

    KM1

    O

    I

    KM2

    K2

    K1

    KM1

    KM2

    M

    XPS

    XCS M

    XCS MP

    Schemes

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • 8/10/2019 xcsa

    12/271/210

    5

    Type of switch Without locking of actuator

    References of switches without actuator ( NC contact with positive opening operation) with 1 or 2 cable entries tapped ISO M16 x 1.5

    2-pole NC + NO (2)break before make,slow break 22

    21

    13

    14

    XCS PA592

    2-pole NC + NO (2)snap action

    22

    21

    13

    14

    XCS PA192

    2-pole NO + NC (2)make before break,slow break 22

    21

    13

    14

    XCS PA692

    2-pole NC + NC (2)slow break

    11

    12

    21

    22

    XCS PA792

    2-pole NC + NC (2)snap action

    11

    12

    21

    22

    XCS PA292

    3-pole NC + NO + NO (2)(2 NO staggered) slow break

    33

    34

    22

    21

    13

    14

    XCS PA892 XCS TA592

    3-pole NC + NO + NO (2)snap action

    33

    34

    22

    21

    13

    14

    XCS PA392

    3-pole NC + NC + NO (2)(NO staggered) slow break

    32

    31

    13

    14

    22

    21 XCS PA992 XCS TA792

    3-pole NC + NC + NO (2)snap action

    32

    3

    1

    1

    3

    14

    22

    21

    XCS PA492

    3-pole NC + NC + NC (2)slow break

    12

    11

    22

    21

    32

    31 XCS TA892

    Weight (kg) 0.110 0.160

    References of switches without actuator ( NC contact with positive opening operation) with 1 or 2 cable entries tapped Pg 11 or 1/2" NPT

    To order a switch with 1 or 2 cable entries for n 11 (Pg 11) cable gland (clamping capacity 7 to 10 mm), replace the last number (2) by 1in the selected reference.Example: XCS PA592 becomes XCS PA591.To order a switch with 1 or 2 cable entries for 1/2" NPT conduit (one n 11 tapped entry tted with metal adaptor DE9 RA1012), replace the last number (2) by 3 inthe selected reference. Example: XCA TA592 becomes XCS TA593.

    Complementary characteristics not shown under general characteristics (page 1/200)

    Actuation speed Maximum: 0.5 m/s, minimum: 0.01 m/s

    Resistance to forcible withdrawal of actuator XCS PA, XCS TA:10 N (50 N using actuators XCS Z12or XCS Z13together with guardretaining device XCS Z21)

    Mechanical durability XCS PA, XCS TA: > 1 million operating cycles

    Maximum operating rate For maximum durability: 600 operating cycles per hour

    Minimum force for positive opening u15 N

    Cable entry XCS PA: 1 entry tapped M16 x 1.5 for ISO cable gland.XCS TA: 2 entries tapped M16 x 1.5 for ISO cable gland.

    Materials Body and head: polyamide PA66, breglass impregnated

    References of accessories

    XCS Z91

    809927

    XCS Z200

    DF523736

    Description For use with Unit referenceWeight

    kg

    Blanking plugs for operating head slot

    (Sold in lots of 10)XCS PA, XCS TA XCS Z28 0.050

    Padlocking device to prevent insertionof actuator, for up to 3 padlocks

    (padlocks not included)

    XCS PA, XCS TA XCS Z91 0.053

    Actuator centring device(3)

    (Fixing screws included)

    XCS PA, XCS TA XCS Z200 0.022

    (1) Head adjustable in 90 steps throughout 360. Blanking plug for operating head slot included with switch.(2) Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head ofthe switch.

    (3) Do not use with XCS Z91.

    Other versions: please consult our Customer Care Centre.

    Safety detection solutions 0Guard switches, actuator operatedPlastic, turret head(1), types XCS PA and XCS TA1 or 2 cable entries

    References

    4

    5

    6

    0

  • 8/10/2019 xcsa

    13/271/211

    5

    Safety detection solutions 0Guard switches, actuator operatedPlastic, turret head, types XCS PA and XCS TA1 or 2 cable entries

    References (continued),dimensions

    References of actuators and guard retaining device

    Description Straightactuator

    Actuator with widexing (1)

    Pivotingactuator

    Right-angledactuator

    Guard retainingdevice (2)

    For guard switches XCS PA, TA XCS Z11 XCS Z12 XCS Z15 XCS Z13 XCS Z14 XCS Z21

    Weight (kg) 0.015 0.015 0.012 0.085 0.025 0.080

    (1) 2 actuator lengths, XCS Z12: L = 40 mm, XCS Z15: L = 29 mm.(2) Only for use with guard switches XCS PA and XCS TA (without actuator centring device XCS Z200) used in conjunction with actuators XCS Z12, XCS Z13 or

    XCS Z15.

    Dimensions

    XCS PAp

    91, XCS PAp

    92 XCS PAp

    93

    34

    30

    93.5

    39

    307

    30

    20/22= =

    13

    .5

    (1) 30

    13.2

    (1) 1 tapped entry for cable gland: 2 elongated holes 4.3 x 8.3 on 22 centres, 2 holes 4.3 on20 centres

    (1) 1 tapped entry tapped for 1/2" NPT conduit: 2 elongated holes 4.3 x 8.3 on 22 centres, 2 holes 4.3 on 20 centres

    XCS TAp9p Actuator centring device XCS Z200

    1/2" NPT conduit adaptor M16 x 1.5 adaptor

    DE9 RA1012 DE9 RA1016

    (1) Tapped entry for 1/2" NPT conduit

    (2) Pg 11 threaded shank

    (1) M16 x 1.5 tapped entry

    (2) Pg 11 threaded shank

    (1) 2 tapped entries for cable gland or 1/2" NPT conduit adaptor(2) 2 elongated holes 4.3 x 8.3 on 22 centres, 2 holes 4.3 on

    20 centres(3) 2 elongated holes 5.3 x 13.3

    34

    (1) 13.2

    30

    93.

    5

    39

    20/22= =

    30 30

    30

    7

    29.

    85

    18

    4

    5.5

    35.35

    6.4

    2 x 3

    2 x 5.5

    17.

    4

    6.

    4

    29.85

    17.4

    5.

    8

    39

    20/22

    52

    40.3

    114.5

    12.5

    12.5

    30

    30

    (1)

    (3)34

    307

    21

    26

    13(1)

    24

    References:page 1/210

    Schemes:page 1/213

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • 8/10/2019 xcsa

    14/271/212

    5

    Safety detection solutions 0Guard switches, actuator operatedPlastic, turret head, types XCS PA and XCS TA1 or 2 cable entries

    Dimensions (continued)XCS Z11 XCS Z12, XCS Z15

    (1) Adaptor (included with actuator XCS Z11) for replacing, without drillingadditional xing hole, a guard switch XCK T with actuator XCK Y01 by aguard switch XCS TA with actuator XCS Z11.

    a: 2 elongated holes 4.7 x 10 : 2 elongated holes 4.7 x 10

    b: 1 elongated hole for M4 or M4.5 screw L = 40 mm (XCS Z12) or 29 mm (XCS Z15)

    XCS Z13 XCS Z14

    : 2 elongated holes 4.7 x 10 : 1 elongated hole 4.7 x 10

    Operating radius required for actuator

    XCS Z11 XCS Z12, XCS Z15

    d = 46 mm (XCS Z12) or 35 mm (XCS Z15)

    XCS Z13 XCS Z14

    R = minimum radius

    5

    3765 2

    4.

    7

    4.

    7

    12

    22

    15

    13

    12

    22

    15

    L

    2

    26

    ==

    2

    13

    40

    =

    =

    55

    11

    6

    55

    66

    28.5

    52

    6

    27

    13

    35

    =

    =

    32

    26

    23

    2

    5

    42.5

    2

    26

    42.

    5

    12

    13

    22

    12

    4.7

    15

    R=1500

    R=1200

    71 71

    R=1500

    R=1200

    dd

    R=300

    R=150

    72 72

    R=1500

    R=1200

    48

    48

    References:page 1/210

    Schemes:page 1/213

    Dimensions (continued)

    4

    5

    6

    0

  • 8/10/2019 xcsa

    15/271/213

    5

    Safety detection solutions 0Guard switches, actuator operatedPlastic, turret head, types XCS PA and XCS TA1 or 2 cable entries

    Setting-upFunctional diagrams

    XCS PA1pp

    XCS PA2pp

    XCS PA3pp

    XCS PA4pp

    XCS PA5pp

    ,XCS TE5ppp XCS PA6pp

    ,XCS TE6ppp XCS PA7pp

    ,XCS TE7ppp XCS TA5pp

    ,XCS PA8pp XCS TA7pp

    ,XCS PA9pp

    Contact operation

    G Closed H Open G Unstable

    Setting-up Schemes Note: These schemes are given as examples only, the designer must refer to the relevant safety standards for guidance.Functional diagrams Wiring to PL=b, category 1 conforming to

    EN/ISO 13849-1

    Wiring to PL=d, category 3 conforming to

    EN/ISO 13849-1

    XCS TA8pp

    Example with 3-pole NC + NO + NO contact and protectionfuse to prevent shunting of the NC contact, either by cabledamage or by tampering.

    Example with 2-pole NC + NO contact with mixed redundancy ofthe contacts and the associated control relays. To activate K1, it isnecessary to remove and re-insert the actuator when the supplyis switched on.

    Contact operationG ClosedH OpenGUnstable

    (1) Signalling contact.

    Wiring to PL=e, category 4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508

    Wiring method used in conjunction with safety module

    (The guard switch should be used in conjunction with a safety limit switch to give electrical/mechanical redundancy)Method for machines with quick rundown time (low inertia)

    Locking or interlocking device based on the principle of redundancy and self-monitoring.

    The safety modules ensure these functions.

    Locking of actuator and operation in positive mode associated with a safety module.

    16

    19

    24

    21-2213-1421-2213-14

    16

    19

    24

    11-1221-2211-1221-22

    16

    19

    24

    21-2213-1433-3421-2213-1433-34

    16

    19

    24

    21-2231-3213-1421-2231-3213-14

    17

    16

    17.5

    18.5

    24

    21-22

    13-14

    15

    17

    24

    21-22

    13-14

    17

    18.5

    17

    18.5

    24

    11-12

    21-22

    17

    19

    24

    21-22

    13-14

    16

    19

    33-34

    17

    16

    17.5

    19

    24

    21-22

    13-14

    31-32

    16.5

    17

    24

    11-12

    21-22

    31-32

    X

    F1

    (1)

    O

    I

    X

    22

    21

    13

    14

    33

    34

    M

    F1

    K2

    K1 K2

    14

    13

    22

    21

    K1

    K2

    K1

    KM1

    O

    I

    KM2

    K2

    K1

    KM1

    KM2

    M

    XPS

    Setting-up, schemes

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • 8/10/2019 xcsa

    16/271/214

    5

    Safety detection solutions 3Guard switches, actuator operatedwith solenoid interlocking, turret headMetal, type XCS EPlastic, double insulated, type XCS TE

    Presentation,characteristics

    Metal, type XCS E Guard switches with locking of the actuator

    Page 1/216

    Plastic, type XCS LE Guard switches with locking of the actuator

    Page 1/222

    Environment characteristicsGuard switch type XCS E (metal) XCS TE (plastic)

    Conformity to standards Products EN/IEC 60947-5-1, UL 508, CSA C22-2 n 14

    Machine assemblies EN/IEC 60204-1, EN/ISO 14119

    Product certifcations UL, CSA UL, CSA

    Maximum safety level(1) PL=e, category 4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508

    Reliability data B10d 5,000,000 (data value for a service life of 10 years can be limited by contact and mechanical wear)

    Protective treatment Standard version: TC

    Ambient air temperature For operation - 25+ 40C - 25+ 60C

    For storage - 40+ 70C

    Vibration resistance 5 gn (10500 Hz) conforming to EN/IEC 60068-2-6

    Shock resistance 10 gn (duration 11 ms) conforming to EN/IEC 60068-2-27

    Electric shock protection Class I conforming to EN/IEC 60536 Class II conforming to EN/IEC 60536

    Degree of protection IP 67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1(2)

    Cable entry 2 entries tapped ISO M20 x 1.5 (clampingcapacity 7 to 13 mm) or tapped for n 13(Pg 13.5) cable gland conforming toNFC 68-300 (clamping capacity 8 to 12 mm)or for 1/2" NPT (USAS B2-1) conduit

    1 entry tapped M16 x 1.5 (clamping capacity4.5 to 10 mm) or tapped for n 11 (Pg 11) cablegland conforming to NFC 68-300 (clampingcapacity 7 to 10 mm) or for 1/2" NPT conduitusing metal adaptor DE9 RA1012 in n 11(Pg 11) tapped entry

    Connecting cable 4 x 0.5 mm2

    Materials Zamak case Polyamide PA66 breglass impregnated case

    Actuators (all types): steel XC60, surface treated

    (1) Using an appropriate and correctly connected control system.

    (2) Live parts of these switches are protected against the penetration of dust and water.However, when installing take all necessary precautions to prevent the penetration of solidbodies, or liquids with a high dust content, into the actuator aperture. Not recommended foruse in saline atmospheres.

    4

    5

    6

    0

  • 8/10/2019 xcsa

    17/271/215

    5

    Safety detection solutions 3Guard switches, actuator operatedwith solenoid interlocking, turret headMetal, type XCS EPlastic, double insulated, type XCS TE

    Characteristics (continued)

    Contact block characteristicsRated operational characteristics 2 and 3 contact,

    slow breakXCS E,XCS TE:aAC-15, B300: Ue = 240 V, Ie = 1.5 A or Ue = 120 V, Ie = 3 A

    All models:cDC-13, Q300: Ue = 250 V, Ie = 0.27 A or Ue = 125 V, Ie = 0.55 A

    conforming to EN/IEC 60947-5-1

    Conventional thermal current in enclosure XCS E, XCS TE 2 and 3 slow break contact versions: Ithe = 6 A

    Rated insulation voltage 2 and 3 contact 3 contact (XCS E), 2 contact (XCS TE):Ui = 500 V conforming to EN/IEC 60947-1; Ui = 300 V conforming to UL 508, CSA C22-2 n 14

    Rated impulse withstand voltage 2 and 3 contact 3 contact (XCS E), 2 contact (XCS TE): Uimp = 6 kV conforming to EN/IEC 60947-5-1

    Positive operation NC contacts with positive opening operation conforming to EN/IEC 60947-5-1, Section 3

    Resistance across terminals y30 mWconforming to EN/IEC 60947-5-4

    Short-circuit protection 2 and 3 contact 3 contact (XCS E), 2 contact (XCS TE): 10 A cartridge fuse type gG (gl)

    Connection Screw clampterminals

    2 and 3 contact 3 contact (XCS E), 2 contact(XCS TE):Clamping capacity, min: 1 x 0.5 mm2, max: 2 x 1.5 mm2with or without cable end

    Complementary characteristicsActuation speed Maximum: 0.5 m/s, minimum: 0.01 m/s

    Resistance to forcible withdrawal of actuator XCS E: 2000 N; XCS TE: 500 N

    Mechanical durability XCS E: > 1 million operating cyclesXCS TE: 1 million operating cycles

    Maximum operating rate For maximum durability: 600 operating cycles per hour

    Minimum force for extraction of actuator u20 N

    Materials Body and head: zamak (XCSE)Body and head: polyamide PA66, breglass impregnated (XCSTE)

    Electrical durability

    Conforming to EN/IEC 60947-5-1 Appendix C.Utilisation categories AC-15 and DC-13.Maximum operating rate: 3600 operating cycles/hour.Load factor: 0.5

    3 contact XCS E and 2 contact XCS TE version, slow break

    AC supply50/60 Hzaoinductive circuit

    DC supplycPower broken in W for5 million operating cycles.

    Voltage V 24 48 120

    o W 13 9 7

    Millionsofoperatingcycles

    Current in A

    0.5 1 2 3 4 5 100.1

    0.2

    0.5

    1

    5

    2

    43

    Ithe

    230 V 12/24/48 V

    110 V

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • 8/10/2019 xcsa

    18/271/216

    5

    Safety detection solutions 3Guard switches, actuator operatedwith solenoid interlocking, turret head (1)

    Metal, type XCS E, with 2 cable entries

    Type of switch Locking on de-energisation and unlocking on energisation

    of solenoid (2)

    LED indication Orange LED: guard open signalling.Green LED: guard closed and locked signalling.

    Supply voltage of solenoid aor 24 Vc(50/60 Hz ona)

    aor48 Vc

    (50/60 Hzona)

    aor 110/120 Vc(3)(50/60 Hz ona)

    aor 220/240 Vc(3)(50/60 Hz ona)

    Type of contact on solenoid NO + NO 2 NC NC + NO NC + NO 2 NC NC + NO 2 NC

    References of switches without actuator ( NC contact with positive opening operation) with 2 cable entries tapped ISO M20 x 1.5

    3-poleNC + NO + NO (2 NO staggered)slow break(4)

    33

    34

    22

    21

    13

    14

    XCS E5312 XCS E5322 XCS E5332 XCS E5342

    3-poleNC + NC + NO (NO staggered)slow break(4)

    32

    31

    13

    14

    22

    21 XCS E7312 XCS

    E73127 XCS E7332 XCS

    E73327XCS E7342 XCS

    E73427

    3-poleNC + NC + NCslow break(4)

    12

    11

    22

    21

    32

    31 XCS E8312

    (5)XCSE83127

    (5)

    XCS E8322(5)

    XCS E8332 XCS E8342

    Weight (kg) 1.140 1.140 1.140 1.140 1.140

    References of switches with locking on energisation and unlocking on de-energisation

    To order a guard switch with locking on energisation and unlocking on de-energisation of the solenoid, replace the 2nd number (3) by 5in the references shownabove. Example: XCS E5312 becomes XCS E5512.

    References of switches with 2 cable entries tapped Pg 13.5 or 1/2" NPT

    To order a switch with 2 cable entries for n 13 (Pg 13.5) cable gland:replace the last number (2) by 1in the selected reference. Example: XCS E5312 becomes XCS E5311.- for switches with 7 at the end of the reference, replace the 2 before the 7 by 1in the selected reference. Example: XCS E73127 becomes XCS E73117.To order a switch with 2 cable entries for 1/2" NPT conduit:- replace the last number (2) by 3in the selected reference. Example: XCS E5312 becomesXCS E5313.- for switches with 7 at the end of the reference, replace the 2 before the 7 by 3in the selected reference. Example: XCS E73127 becomes XCS E73137.

    References of actuators (see page 1/222)

    Solenoid characteristics

    Load factor 100%

    Rated operational voltage aorc24 V

    aorc24 V

    aorc48 V

    aorc110/120 V

    aorc220/240 V

    Voltage limits Conforming to EN/IEC 60947-1 - 20%, + 10% of the rated operational voltage (including ripple onc)

    Service life 20 000 hours

    Consumption Inrush: 10 VA. Sealed: 10 VA

    LED indicator characteristics

    Rated insulation voltage 50 V conforming to EN/IEC 60947-1 250 V conforming to EN/IEC 60947-1

    Current consumption 7 mA 7 mA

    Rated operational voltage aor 24/48 Vc 110/240 Va

    Voltage limits aor 20...52 Vc(including ripple) 95...264 Va(including ripple)

    Service life 100,000 hours 100 000 hours

    Protection against overvoltages Yes Yes

    (1) Head adjustable in 90 steps throughout 360. Blanking plug for operating head slot included with switch.(2) A key operated lock (2 keys included with switch) enables forced opening of the interlocking mechanism, by authorised personnel, allowing withdrawal of theactuator and subsequent opening of the NC safety contacts.(3) For use on 110/120 Vcor 220/240 Vc, remove the LED indicator module.(4) Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch.(5) Switches supplied with a single green LED.

    Other versions:please consult our Customer Care Centre.

    References,characteristics

    Dimensions:page 1/218

    Schemes:page 1/219

    4

    5

    6

    0

  • 8/10/2019 xcsa

    19/271/217

    5

    Separate componentsDescription For use

    withSupply voltage Reference Weight

    kg

    1 orange LED +1 green LED indicatormodule with cover +lock (1), seal and 4xing screws (2 keysincluded for lock)

    XCS E73pp aor 24/48 Vc XCS Z43 0.175

    Description For usewith

    Key withdrawal positionsfrom lock

    Unit reference Weightkg

    Blanking plugs foroperating head slot(Sold in lots of 10)

    XCS E XCS Z27 0.050

    Keys for interlockforced openingdevice(Sold in lots of 10)

    XCS E XCS Z25 0.100

    Padlocking deviceto prevent preventinsertion of actuator,for up to 3 padlocks(padlocks not included)

    XCS E XCS Z90 0.055

    Description For use with Unit reference Weightkg

    1/2" NPT conduitadaptor(Sold in lots of 5)

    XCS E DE9 RA2012 0.048

    M20 x 1.5 adaptor(Sold in lots of 5)

    XCS E DE9 RA13520 0.010

    (1) Lock incorporated as standard on guard switches XCS E: key withdrawal in LOCK andUNLOCK positions.

    XCS Z4p

    809848

    809849

    XCS Z90

    809850

    Safety detection solutions 0Guard switches, actuator operatedwith solenoid interlocking, turret headMetal, type XCS E, with 2 cable entries

    References

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • 8/10/2019 xcsa

    20/271/218

    5

    Safety detection solutions 0Guard switches, actuator operatedwith solenoid interlocking, turret headMetal, type XCS E, with 2 cable entries

    Dimensions

    DimensionsGuard switchesXCS Epppp

    98

    26

    33 3.5

    95

    12

    43.5

    6

    113

    88= =

    48

    33

    146

    38

    7

    16(1)

    44

    26

    (1)

    (1)

    5.3

    (1) 1 tapped entry for cable gland.

    : 2 elongated holes 5.3 x 7.3

    M20 x 1.5 adaptor 1/2" NPT conduit adaptor

    DE9 RA13520 DE9 RA2012

    19 28

    24

    21.3 (2)(1)

    26

    (1) M20 x 1.5 tapped entry

    (2) Pg 13.5 threaded shank

    (1) Tapped entry for 1/2" NPT conduit

    (2) M20 x 1.5 threaded shank

    References:page 1/216

    4

    5

    6

    0

  • 8/10/2019 xcsa

    21/271/219

    5

    Safety detection solutions 0Guard switches, actuator operatedwith solenoid interlocking, turret headMetal, type XCS E, with 2 cable entries

    Setting-up,schemes

    Setting-upFunctional diagrams

    XCSp

    5ppp

    XCSp

    7ppp

    XCSp

    8ppp

    Contact operation

    GClosed

    HOpen

    GUnstable

    Schemes Note: These schemes are given as examples only, the designer must refer to the relevant safety standards for guidance.Wiring to PL=b, category 1 conforming toEN/ISO 13849-1

    Wiring to PL=d, category 3 conforming to

    EN/ISO 13849-1

    Example with 3-pole NC + NO + NO contact and protectionfuse to prevent shunting of the NC contact, either by cabledamage or by tampering.

    Example with 3-pole NC + NO + NO contact with mixed redundancy of the contacts and theassociated control relays. To activate K1, it is necessary to remove and re-insert the actuatorwhen the supply is switched on.

    (1) Signalling contact H1: actuator not inserted indicator

    Wiring to PL=e, category 4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508. Wiring method used in conjunction

    with Preventa safety module (The guard switch should be used in conjunction with a safety limit switch to give electrical/mechanical redundancy).

    Method for machines with long rundown time (high inertia)

    Interlocking device for actuator tted on guard and zero speed detection.

    23

    21

    22.5

    25

    31

    21-22

    13-14

    33-34

    23

    21.5

    22

    25

    31

    21-22

    31-32

    13-14

    23

    25

    31

    11-12

    21-22

    31-32

    X

    F1

    O

    I

    X

    22

    21

    13

    14

    33

    34

    M

    (1)

    F1

    K2

    K1 K2

    14

    13

    34

    33

    22

    21

    K1

    K2

    K1

    KM1

    O

    I

    KM2

    H1

    K2

    K1

    KM1

    KM2

    M

    XPS

    XPS

    VNE

    References:page 1/216

    Dimensions:page 1/218

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • 8/10/2019 xcsa

    22/271/220

    5

    Safety detection solutions 0Guard switches, actuator operatedwith solenoid interlocking, turret headMetal, type XCS E, with 2 cable entries

    Schemes

    Wiring to PL=b, category 1 conforming to EN/ISO 13849-1

    Wiring examples with protection fuse to prevent shunting of the NC contact, either by cable damage or by tampering.

    Locking on de-energisation, NC + NO + NO Locking on energisation, NC + NO + NO

    XCS E53pp XCS E55pp

    (1) Solenoid (1) Solenoid

    (2) Auxiliary contact (2) Auxiliary contact

    E1-E2: Solenoid supply E1-E2: Solenoid supply

    43-44: Solenoid signalling contact 51-52: Solenoid signalling contact

    13-14: Safety contact, available for redundancy 13-14: Safety contact, avai lable for redundancy

    33-X1: LED (orange): actuator withdrawn 33-X1: LED (orange): actuator withdrawn

    51-X1: LED (green): actuator inserted and locked 43-X1: LED (green): actuator inserted and locked

    21-52: Safety pre-wiring obligatory 21-44: Safety pre-wiring obligatory

    X

    O

    I

    X

    21

    F1

    22

    51

    52

    1413

    3433

    X3

    X1

    X2O G G N

    M

    E2

    E1

    44

    43

    (1)

    (2)

    X

    O

    I

    X

    21

    F1

    22

    51

    52

    1413

    3433

    X3

    X1

    X2O G G N

    M

    E2

    E1

    44

    43

    (1)

    (2)

    References:page 1/216

    Dimensions:page 1/218

    4

    5

    6

    0

  • 8/10/2019 xcsa

    23/271/221

    5

    Safety detection solutions 0Guard switches, actuator operatedwith solenoid interlocking, turret headMetal, type XCS E, with 2 cable entries

    Schemes

    Wiring to PL=d, category 3 conforming to EN/ISO 13849-1

    Wiring examples with redundancy for the guard switch contacts, without monitoring or redundancy in the power circuit

    Locking on de-energisation, NC + NC + NO Locking on de-energisation, NC + NC + NO

    XCS E73pp XCS E73pp7

    (1) Solenoid (1) Solenoid

    (2) Auxiliary contact (2) Auxiliary contact

    E1-E2: Solenoid supply E1-E2: Solenoid supply

    43-44: Solenoid signalling contact 41-42 and 51-52: Solenoid signalling contacts

    21-22 and 31-32: Safety contacts, available for redundancy 21-22 and 31-32: Safety contacts, available for redundancy

    13-X1: LED (orange): actuator withdrawn 13-X1: LED (orange): actuator withdrawn

    51-X1: LED (green): actuator inserted and locked 51-X1: LED (green): actuator inserted and locked

    21-52: Safety pre-wiring obligatory 21-52 and 42-31: Safety pre-wiring obligatory

    Locking on energisation, NC + NC + NO

    XCS E75pp

    (1) Solenoid

    (2) Auxiliary contact

    E1-E2: Solenoid supply

    51-52: Solenoid signalling contact21-22 and 31-32: Safety contacts, available for redundancy

    13-X1: LED (orange): actuator withdrawn

    43-X1: LED (green): actuator inserted and locked

    21-44: Safety pre-wiring obligatory

    K1 K2

    21

    F1

    22

    51

    52

    3231

    1413

    X3

    X1

    X2OG GN

    E2

    E1

    44

    43

    (1)

    (2)

    KM2

    O

    I

    KM1

    KM2

    K1

    K2

    F2

    M

    KM1

    K1 K2

    21

    F1

    22

    51

    52

    3231

    1413

    X3

    X1

    X2OG GN

    E2

    E1

    42

    41

    (1)

    (2)

    KM2

    O

    I

    KM1

    KM2

    K1

    K2

    F2

    M

    KM1

    KM2

    O

    I

    K1 K2

    KM1

    KM2

    21

    F1

    22

    51

    52

    32 K1

    K2

    31

    1413

    X3

    X1

    X2OG GN

    E2

    E1

    44

    43

    F2

    (1)

    (2)

    M

    KM1

    References:page 1/216

    Dimensions:page 1/218

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • 8/10/2019 xcsa

    24/271/222

    5

    References,

    characteristics (continued)

    Type of switch Locking on de-energisation and unlocking on energisation of solenoid (2)

    Supply voltage of solenoid aor 24 Vc(50/60 Hz ona) aor 120 Vc(50/60 Hz ona) aor 230 Vc(50/60 Hz ona)

    References of switches without actuator ( NC contact with positive opening operation)

    with 1 cable entry tapped ISO M16 x 1.5 (2)2-pole NC + NC(3)break before make,slow break 22

    21

    13

    14

    XCS TE5312 XCS TE5332 XCS TE5342

    2-pole NO + NC (3)make before break,slow break 22

    21

    13

    14

    XCS TE6312 XCS TE6332 XCS TE6342

    2-pole NC + NC(3)slow break1

    1

    12

    2

    1

    22

    XCS TE7312 XCS TE7332 XCS TE7342

    Weight (kg) 0.360 0.360 0.360

    References of switches with locking on energisation and unlocking on de-energisationTo order a guard switch with locking on energisation and unlocking on de-energisation of the solenoid, replace the 2 ndnumber (3) by5. Example: XCS TE5312becomes XCS TE5512.

    References of switches with 1 cable entry tapped Pg 11 or 1/2" NPTTo order a switch with 1 cable entry for n 11 (Pg 11) cable gland, replace the last number (2) by 1in the selected reference.Example: XCS TE5312 becomes XCS TE5311.To order a switch with 1 cable entry for 1/2" NPT (USAS B2-1) conduit, replace the last number (2) by 3in the selected reference.Example: XCS TE5312 becomes XCS TE5313. The n 11 (Pg 11) tapped entry is tted with metal adaptor DE9 RA1012 for 1/2" NPT conduit.

    Solenoid characteristicsLoad factor 100%

    Rated operational voltage aor 24 Vc aor 120 Vc aorc230 V

    Voltage limits - 20%, +10% of the rated operational voltage (including ripple onc) conforming toEN/IEC 60947-1

    Service life 20 000 hours

    Consumption 10 VA max.

    References of actuators and guard retaining device

    Description Straight actuator Actuator with wide xing (4) Pivoting actuator Right-angled actuator

    For guard switches XCS E and XCS TE XCS Z11 XCS Z12 XCS Z15 XCS Z13 XCS Z14

    Weight (kg) 0.015 0.015 0.012 0.085 0.025

    References of accessoriesDescription For use

    withUnit reference Weight

    kg

    Blanking plugs for operating head slot(Sold in lots of 10)

    XCS TE XCS Z28 0.050

    Tool for forced opening of interlockingdevice(Sold in lots of 10)

    XCS TE XCS Z100 0.050

    Padlocking device to prevent insertionof actuator, for up to 3 padlocks(padlocks not included)

    XCS TE XCS Z91 0.053

    Actuator centring device (5)(Fixing screws included)

    XCS TE XCS Z200 0.022

    1/2" NPT conduit adaptor(Sold in lots of 10)

    XCS TE DE9 RA1012 0.048

    M16 x 1.5 adaptor(Sold in lots of 10) XCS TE DE9 RA1016 0.048

    (1) Head adjustable in 90 steps throughout 360. Blanking plug for operating head slot included with switch.(2) A special tool included with the guard switch enables forced opening of the interlocking mechanism, by authorised personnel, allowing withdrawal of the actuator andsubsequent opening of the NC safety contacts.(3) Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch.(4) 2 actuator lengths, XCS Z12: L = 40 mm, XCS Z15: L = 29 mm.(5) Do not use with XCS Z91.

    Other versions: please consult our Customer Care Centre.

    XCS Z91

    809927

    XCS Z200

    DF523736

    Safety detection solutions 3Guard switches, actuator operatedwith solenoid interlocking, turret head (1)Plastic, type XCS TE, with 1 cable entry

    Dimensions:page 1/223

    Schemes:page 1/225

    4

    5

    6

    0

  • 8/10/2019 xcsa

    25/271/223

    5

    Dimensions (continued)

    DimensionsGuard switches Actuator centring deviceXCS TEpppp

    XCS Z200

    1/2" NPT conduit adaptor M16 x 1.5 adaptor

    DE9 RA1012 DE9 RA1016

    (1) Tapped entry for 1/2" NPT conduit

    (2) Pg 11 threaded shank

    (1) M16 x 1.5 tapped entry

    (2) Pg 11 threaded shank

    (1) 1 tapped entry for cable gland: 2 elongated holes 4.3 x 8.3 on 22 centres, 2 holes 4.3 on 20 centres

    21

    26

    13(1)

    24

    ActuatorsXCS Z11 XCS Z12, XCS Z15

    (1) Adaptor (included with actuator XCS Z11) for replacing, without drillingadditional xing hole, a guard switch XCK T with actuator XCK Y01 by aguard switch XCS TA with actuator XCS Z11.

    a: 2 elongated holes 4.7 x 10 : 2 elongated holes 4.7 x 10

    b: 1 elongated hole for M4 or M4.5 screw L = 40 mm (XCS Z12) or 29 mm (XCS Z15)

    XCS Z13 XCS Z14

    : 2 elongated holes 4.7 x 10 : 1 elongated hole 4.7 x 10

    5

    3765 2

    4.

    7

    4.7

    12

    22

    15

    13

    12

    22

    15

    Adaptor shank (1)

    L

    2

    26

    ==

    2

    13

    40

    =

    =

    55

    11

    6

    55

    66

    28.5

    5

    2

    6

    27

    13

    35

    =

    =

    32

    26

    23

    2

    5

    42.5

    2

    26

    42.

    5

    12

    13

    22

    12

    4.7

    15

    References:page 1/222

    Safety detection solutions 3Guard switches, actuator operatedwith solenoid interlocking, turret headPlastic, type XCS TE, with 1 cable entry

    29.

    85

    18

    4

    5.5

    35.35

    6.4

    2 x 3

    2 x 5.5

    17.

    4

    6.

    4

    29.85

    17.4

    5.8

    38

    (1)

    33

    14.5

    7

    30

    20/22 4

    110

    43

    15

    93.5

    40

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • 8/10/2019 xcsa

    26/271/224

    5

    Safety detection solutions 3Guard switches, actuator operatedwith solenoid interlocking, turret headPlastic, type XCS TE, with 1 cable entry

    Setting-up,schemes

    Operating radius required for actuator

    XCS Z11 XCS Z12, XCS Z15

    d = 46 mm (XCS Z12) or 35 mm (XCS Z15)

    XCS Z13 XCS Z14

    R = minimum radius

    R=1500

    R=1200

    71 71

    R=1500

    R=1200

    dd

    R=300

    R=150

    72 72

    R=1500

    R=1200

    48

    48

    Setting-up Schemes

    Functional diagrams Wiring to PL=d, category 3 conforming to EN/ISO 13849-1XCS TE5ppp XCS TE6ppp XCS TE7ppp Example with 2-pole NC + NO contact with mixed redundancy of the contacts

    and the associated control relays. To activate K1, it is necessary to remove andre-insert the actuator when the supply is switched on.

    Contact operation

    GClosed

    HOpen

    GUnstable

    Schemes (continued)Wiring to PL=e, category 4 conforming to EN/ISO 13849-1

    and SIL 3 conforming to EN/IEC 61508

    (The guard switch should be used in conjunction with a safety limit switch togive electrical/mechanical redundancy)

    Method for machines with long rundown time (high inertia)

    Interlocking device for actuator tted on guard and zero speed detection.

    17

    16

    17.5

    18.5

    24

    21-22

    13-14

    15

    17

    24

    21-22

    13-14

    17

    18.5

    17

    18.5

    24

    11-12

    21-22

    F1

    K2

    K1 K2

    14

    13

    22

    21

    K1

    K2

    K1

    KM1

    O

    I

    KM2

    K2

    K1

    KM1

    KM2

    M

    XPS

    XPS

    VNE

    (1) These schemes are given as examples only, the designer must refer to the relevant safety standards for guidance.

    4

    5

    6

    0

  • 8/10/2019 xcsa

    27/27

    5

    Safety detection solutions 3Guard switches, actuator operatedwith solenoid interlocking, turret headPlastic, type XCS TE, with 1 cable entry

    Schemes

    Schemes (continued)Wiring to PL=b, category 1 conforming to EN/ISO 13849-1

    Wiring examples with protection fuse to prevent shunting of the NC contact, either by cable damage or by tampering.Locking on de-energisation Locking on energisation

    NC + NO

    XCS TE53pp

    NC + NO

    XCS TE55pp

    (1) Solenoid (1) Solenoid

    (2) Auxiliary contact (2) Auxiliary contact

    E1-E2: Solenoid supply E1-E2: Solenoid supply

    13-14: Safety contact, available for redundancy or signall ing 13-14: Safety contact, available for redundancy or signall ing

    Wiring to PL=d, category 3 conforming to EN/ISO 13849-1

    Wiring examples with redundancy for the guard switch contacts, without monitoring or redundancy in the power circuit

    Locking on de-energisation Locking on energisation

    NC + NC

    XCS TE73pp

    NC + NC

    XCS TE75pp

    (1) Solenoid (1) Solenoid

    (2) Solenoid auxiliary contact (2) Solenoid auxiliary contact

    E1-E2: Solenoid supply E1-E2: Solenoid supply

    11-12: Safety contact, available for redundancy 11-12: Safety contact, available for redundancy

    E2 31 33E1

    F1

    (32) 21 22

    1413

    X

    X

    M

    O

    I

    (1)

    (2)

    E2 31 33E1

    F1

    (2) (34)

    (1)

    21 22

    1413

    X

    X

    M

    O

    I

    E 2 3 1 3 3E1

    F1

    (2) (32)

    (1)

    21 22

    1211

    K1 K2

    KM2

    O

    I

    KM1

    KM2

    K1

    K2

    F2

    M

    KM1

    E2 31 33E1

    F1

    (2) (34)

    (1)

    21 22

    1211

    K1 K2

    KM2

    O

    I

    KM1

    KM2

    K1

    K2

    F2

    M

    KM1

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10