2/271/200
5
Safety detection solutions 3Guard switches, actuator operatedMetal, turret head, types XCS A, XCS and XCS CPlastic, double insulated, turret head,types XCS MP or XCS PA and XCS TA
Metal, types XCS A, XCS B,
XCS C
Guard switches with or without locking of the actuator
Page 1/202
Plastic, types XCS MP, XCS PAXCS TA
Guard switches with or without locking of the actuator
Pages 1/206 and1/210
Presentation,characteristics
Environment characteristicsGuard switch type XCS A, XCS B, XCS C
(metal)XCS MP, XCS PA, XCS TA(plastic)
Conformity to standards Products EN/IEC 60947-5-1, UL 508, CSA C22-2 n 14
Machine assemblies EN/IEC 60204-1, EN/ISO 14119
Product certifcations UL, CSA UL, CSA (cULus for XCS MP)
Maximum safety level (1) PL=e, Category 4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508
Reliability data B10d 5 000 000 (data value for a service life of 10 years can be limited by contact and mechanical wear)
Protective treatment Standard version: TC
Ambient air temperature For operation - 25+ 70C
For storage - 40+ 70C (- 25+ 80C for XCS MP)
Vibration resistance 5 gn (10500 Hz) conforming to EN/IEC 60068-2-6 (6 gn (1055 Hz) for XCS MP)
Shock resistance 10 gn (duration 11 ms) conforming to EN/IEC 60068-2-27 (50 gn (duration 11 ms) for XCS MP)
Electric shock protection Class 1 conforming to EN/IEC 60536 Class 2 conforming to EN/IEC 60536
Degree of protection IP 67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1(2)
Cable entry 1 entry tapped ISO M20 x 1.5 (clampingcapacity 7 to 13 mm) or tapped for n 13(Pg 13.5) cable gland conforming toNFC 68-300 (clamping capacity 9 to 12 mm)or for 1/2" NPT (USAS B2-1) conduit
1 entry (XCS PA) or 2 entries (XCS TA) tappedfor ISO M16 x 1.5 cable gland (clampingcapacity 4.5 to 10 mm) or for n 11 (Pg 11)cable gland, or tapped 1/2" NPT, or for 1/2"NPT (USAS B2-1) conduit using metal adaptorDE9 RA1012) for XCS TA(other entry ttedwith blanking plug).
Connecting cable Pre-cabled, either 4 x 0.5 mm2or 6 x 0.5 mm2(XCS MP)
Materials XCS A/B/CZamak case
XCS MP/PA/TAPolyamide PA66 breglass impregnated case
Actuators (all types): steel XC60, surface treated
(1) Using an appropriate and correctly connected control system.
(2) Live parts of these switches are protected against the penetration of dust and water.
However, when installing take all necessary precautions to prevent the penetration of solidbodies, or liquids with a high dust content, into the actuator aperture. Not recommended foruse in saline atmospheres.
4
5
6
0
8/10/2019 xcsa
3/271/201
5
Safety detection solutions 3Guard switches, actuator operatedMetal, turret head, types XCS A, XCS and XCS CPlastic, double insulated, turret head,types XCS MP or XCS PA and XCS TA
Contact block characteristicsRated operationalcharacteristics
2 and 3 contact, slow break XCS A, XCS B, XCS C,XCS TA,XCS PA:aAC-15, A300: Ue = 240 V, Ie = 3 A orUe = 120 V, Ie = 6 A
XCS MP:aAC-15, C300: Ue = 240 V, Ie = 0.75 A or Ue = 120 V, Ie = 1.5 AAll models:cDC-13, Q300: Ue = 250 V, Ie = 0.27 A or Ue = 125 V, Ie = 0.55 Aconforming to EN/IEC 60947-5-1
2 contact, snap action XCS PA:aAC-15, A300: Ue = 240 V, Ie = 3 A; Ithe = 10 AcDC-13, Q300: Ue = 250 V, Ie = 0.27 A or Ue = 125 V, Ie = 0.55 A conforming to EN/IEC 60947-5-1
3 contact, snap action XCS PA:aAC-15, B300: Ue = 240 V, Ie = 1.5 A; Ithe = 6 AcDC-13, R300: Ue = 250 V, Ie = 0.1 A or Ue = 125 V, Ie = 0.55 A conforming to EN/IEC 60947-5-1
Conventional thermal current in enclosure XCS A, XCS B, XCS C, XCS PA(2 & 3 slow break contact and 2 snap action contact versions)XCS PA (3 snap action contact version): Ithe = 6 AXCS MP: Ithe = 2.5 A
Rated insulation voltage 2 and 3 contact 3 contact (XCS A, XCS B, XCS C, XCS TA), 2 contact (XCS PA),2 and 3 contact (XCS MP):Ui = 500 V conforming to EN/IEC 60947-1; Ui = 300 V conforming to UL 508, CSA C22-2 n 14
3 contact XCS PA:Ui = 400 V degree of pollution 3 conforming to EN/IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n 14Rated impulse withstandvoltage
2 and 3 contact 3 contact (XCS A, XCS B, XCS C, XCS TA), 2 contact (XCS PA),2 and 3 contact (XCS MP): Uimp = 6 kV conforming to EN/IEC 60947-5-1
3 contact XCS PA:Uimp = 4 kV conforming to EN/IEC 60947-5-4
Positive operation NC contacts with positive opening operation conforming to EN/IEC 60947-5-1, Section 3
Resistance across terminals y30 mWconforming to EN/IEC 60947-5-4
Short-circuit protection 2 and 3 contact 3 contact (XCS A,XCS B,XCS C,XCS TA), 2 contact (XCS PA),2 and 3 contact (XCS MP): 10 A cartridge fuse type gG (gl)
3 contact XCS PA:6 A cartridge fuse type gG (gl)
Connection Pre-cabled 4 x 0.5 mm2or 6 x 0.5 mm2(XCS MP). PVC
Screw clampterminals
2 contact, snap action XCS PA, XCS TA:Clamping capacity, min: 1 x 0.34 mm2, max: 2 x 1.5 mm2
2 and 3 contact 3 contact (XCS A, XCS B, XCS C, XCS TA), 2 contact (XCS PA):Clamping capacity, min: 1 x 0.5 mm2, max: 2 x 1.5 mm2with or without cable end
3 contact XCS PA:clamping capacity, min: 1 x 0.34 mm2
, max: 1 x 1 mm2
or 2 x 0.75 mm2
Electrical durability
Conforming to EN/IEC 60947-5-1 Appendix C.Utilisation categories AC-15 and DC-13.Maximum operating rate: 3600 operating cycles/hour.Load factor: 0.5
Only applicable to XCS MP: Conforming to EN/IEC 60947-5-1 Appendix C.Utilisation categories AC-15 and DC-13.Maximum operating rate: 900 operating cycles/hour.
Characteristics (continued)
2 snap action contact version 3 contact version XCS A/B/C/TAand 2 slow break contact version
AC supply50/60 Hzaoinductive circuit
Millionsofoperatingcycles
Current in A
0.1
0.5
1
5
0.5 1 5 10
110 V
48 V
230/400 V
2 3 4
Ithe
24 V
DC supplycPower broken in W for5 million operating cycles.
Voltage V 24 48 120 Voltage V 24 48 120o W 10 7 4 o W 13 9 7
For XE2S Pp151 onaorc, NC and NO contacts simultaneously loaded to the values shown with reverse polarity.
3 snap action contact version XCS PA 3 slow break contact version XCS PA
AC supply50/60 Hzaoinductive circuit
DC supplycPower broken in W for5 million operating cycles.
Voltage V 24 48 120 Voltage V 24 48 120
o W 3 2 1 o W 4 3 2
Millionsofoperatingcycles
Current in A
0.5 1 2 3 4 5 100.1
0.2
0.5
1
5
2
43
Ithe
230 V 12/24/48 V
110 V
0.1
0.5
1
5
0.5 1 5 10
110 V
48 V
230/400 V
2 3 4
24 V
e
Millionsofoperatingcycles
Current in A
Millionsofoperatingcycles
Current in A
0.5 1 2 3 4 5 100.1
0.2
0.5
1
5
2
43
230 V110 V
12/24/48 V
Ithe
1
2
3
4
5
6
7
8
9
10
8/10/2019 xcsa
4/271/202
5
Safety detection solutions 0Guard switches, actuator operatedMetal, turret head(1), types XCS A, XCS B and XCS C1 cable entry
Type of switch Without locking of actuator With locking of actuator, manual unlocking (2)
LED indication on opening of NCcontacts
Without 1 orangeLED24/48 Vz
1 orangeLED110/240 Va
Without 1 orangeLED24/48 Vz
1 orangeLED110/240 Va
Without 1 orangeLED24/48 Vz
1 orangeLED110/240 Va
References of switches without actuator ( NC contact with positive opening operation)
with 1 cable entry tapped ISO M20 x 1.53-pole
NC + NO + NO(2 NO staggered)slow break(3)
33
34
22
2
113
14
XCS A502 XCS A512 XCS A522 XCS B502 XCS B512 XCS B522 XCS C502 XCS C512 XCS C522
3-poleNC + NC + NO(NO staggered)slow break(3) 3
2
31
13
14
22
21 XCS A702 XCS A712 XCS A722 XCS B702 XCS B712 XCS B722 XCS C702 XCS C712 XCS C722
3-poleNC + NC + NCslow break(3)
12
11
22
21
32
31 XCS A802 XCS B802 XCS C802
Weight (kg) 0.440 0.440 0.440 0.475 0.475 0.475 0.480 0.480 0.480
References of switches without actuator ( NC contact with positive opening operation)
with 1 cable entry tapped Pg 13.5
To order a switch with a Pg 13.5 cable entry, replace the last number (2) by 1in the selected reference.Example: XCS A502 becomes XCS A501.
References of switches without actuator ( NC contact with positive opening operation)
with 1 cable entry tapped 1/2" NPTTo order a switch with a 1/2" NPT cable entry, replace the last number (2) by 3in the selected reference.Example: XCS A502 becomes XCS A503.
Complementary characteristics not shown under general characteristics (page 1/200)Actuation speed Maximum: 0.5 m/s, minimum: 0.01 m/s
Resistance to forcible withdrawalof actuator
XCS Band XCS C: 1500 N
Mechanical durability XCS A: > 1 million operating cyclesXCS B and XCS C: 0.6 million operating cycles
Maximum operating rate For maximum durability: 600 operating cycles per hour
Minimum force for extraction of actuator u20 N
Cable entry XCS A, XCS B, XCS C: 1 cable entryEntry tapped ISO M20 x 1.5, clamping capacity 7 to 13 mm
Materials Body: zamak. Head: zamak. Safety screws: 5-lobe torque. Protective plate: steel.
References of actuators
Description Straight actuator Actuator with wide xing Pivoting actuator Latch for sliding doors
For guard switches XCS A, B, C, E XCS Z01 XCS Z02 XCS Z03 XCS Z05
Weight (kg) 0.020 0.020 0.095 0.600
(1) Head adjustable in 90 steps throughout 360. Blanking plug for operating head slot included with switch.
(2) Unlocking by pushbutton for XCS Bpppand by key operated lock for XCS Cppp(2 keys included with switch).
(3) Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch.
Other versions: please consult our Customer Care Centre.
Dimensions:page 1/203
Schemes:page 1/205
References,characteristics
4
5
6
0
8/10/2019 xcsa
5/271/203
5
Separate componentsDescription For use
withSupplyvoltage
Reference Weightkg
1 orange LEDindicator modulewith cover, seal and2 xing screws
XCS AXCS BXCS C
aor 24/48 Vc XCS Z31 0.040
110/240 Va XCS Z32 0.040
Description For use with Unit reference Weightkg
Blanking plugs foroperating head slot(Sold in lots of 10)
XCS A,XCS B,XCS C
XCS Z27 0.050
Keys for interlockforced openingdevice(Sold in lots of 10)
XCS B,XCS C
XCS Z25 0.100
Padlocking deviceto prevent insertion ofactuator,for up to 3 padlocks(padlocks not included)
XCS A,XCS B,XCS C
XCS Z90 0.055
DimensionsGuard switches
XCS Appp XCS Bppp, XCS Cppp
(1) 1 tapped entry for cable gland
: 2 elongated holes 5.3 x 7.3
(1) 1 tapped entry for cable gland
: 2 elongated holes 5.3 x 7.3
XCS Z90
809850
33
60
43.5
1
13.5
40
30= =
38
33
16
44
(1)
7
5.3
Safety detection solutions 0Guard switches, actuator operatedMetal, turret head, types XCS A, XCS B and XCS C1 cable entry
References,dimensions
XCS Z3p
809847
33
60
43.5
113.5
52
28.5
40
30= =
37
16
44
38
33
(1)
7
5.3
1
2
3
4
5
6
7
8
9
10
8/10/2019 xcsa
6/271/204
5
Safety detection solutions 0Guard switches, actuator operatedMetal, turret head, types XCS A, XCS B and XCS C1 cable entry
Dimensions (continued)
Actuators
XCS Z01 XCS Z02
(1) Adaptor (included with actuator XCS Z01) for replacing, without drillingadditional xing hole, a guard switch XCK J with actuator ZCK Y07 bya guard switch XCS A, B, C or E with actuator XCS Z01.
: 2 elongated holes 5.3 x 10 : 2 elongated holes 5.3 x 10
XCS Z03 XCS Z05
Fixing axis % related to actuator. : 4 elongated holes 5.3 x 7.3
Operating radius required for actuator
XCS Z01 XCS Z02
XCS Z03
R = minimum radius
3
=
= 14
35
20 7.5
2.5
=
= 15
25
81.5
33 20 11
Adaptor shank (1)
11
55.52.5
51
35
=
==
=
25
33
2.5
48
76
2.
5
11
40
17
23
33
25
30
30
2.5
11
30
25
5.3
40
11
41
3
2
140
100 2020
4xM5
26
7
742
12.5
115 64
20
6
6
18
R=2000
85
R=2000
85
R=2000
58
R=2000
58
R=15022
55
79
R=400
16.5
79
References:page 1/202
Schemes:page 1/205
4
5
6
0
8/10/2019 xcsa
7/271/205
5
Safety detection solutions 0Guard switches, actuator operatedMetal, turret head, types XCS A, XCS B and XCS C1 cable entry
Setting-up,schemes
Setting-upFunctional diagrams
XCSp
5ppp
XCSp
7ppp
XCSp
8ppp
Contact operation
G Closed
HOpen
GUnstable
Schemes Note: These schemes are given as examples only, the designer must refer to the relevant safety standards for guidance.Wiring to PL=b, category 1 conforming toEN/SO 13849-1
Wiring to PL=d, category 3 conforming to EN/ISO 13849-1
Example with 3-pole NC + NO + NO contact and protectionfuse to prevent shunting of the NC contact, either by cabledamage or by tampering.
Example with 3-pole NC + NO + NO contact with mixed redundancy of the contacts and theassociated control relays. To activate K1, it is necessary to remove and re-insert the actuatorwhen the supply is switched on.
(1) Signalling contact H1: actuator not inserted indicator
Wiring to PL=e, category 4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508. Wiring method used in conjunction
with Preventa safety module (The guard switch should be used in conjunction with a safety limit switch to give electrical/mechanical redundancy).
Method for machines with quick rundown time (low inertia)
Locking device based on the principle of redundancy and self-monitoring.The safety modules ensure these functions.
Locking of actuator and operation in positive mode associatedwith a safety module.
23
21
22.5
25
31
21-22
13-14
33-34
23
21.5
22
25
31
21-22
31-32
13-14
23
25
31
11-12
21-22
31-32
X
F1
O
I
X
22
21
13
14
33
34
M
(1)
F1
K2
K1 K2
14
13
34
33
22
21
K1
K2
K1
KM1
O
I
KM2
H1
K2
K1
KM1
KM2
M
XPS
References:page 1/202
Dimensions:page 1/203
1
2
3
4
5
6
7
8
9
10
8/10/2019 xcsa
8/271/206
5
Safety detection solutions 2Guard switches, actuator operatedPlastic, xed head, type XCS MPPre-cabled, length 2 m, 5 m or 10 m
Type of switch Without locking of actuator
References of switches without actuator ( NC contact with positive opening operation)(1)2-pole NC + NObreak before make, slow break (2)
XCS MP59Lp
2-pole NC + NCslow break (2)
XCS MP79Lp
3-pole NC + NC + NO(NO staggered) slow break (2)
XCS MP70Lp
3-pole NC + NC+ NCslow break (2)
XCS MP80Lp
Weight (kg) 0.110
Complementary characteristics not shown under general characteristics (page 1/200)Actuation speed Maximum: 1.5 m/s, minimum: 0.05 m/s
Resistance to forcible withdrawal of actuator 8 N
Mechanical durability > 1 million operating cycles
Pre-cabled connection 4 x 0.5 mm2or 6 x 0.5 mm2
Maximum operating rate For maximum durability: 1200 operating cycles per hour
Minimum force for extraction of actuator u8 N
References of actuatorsDescription Straight actuator Right-angled
actuator
Pivoting actuator
For right-hand door For left-hand door
For guard switches XCS MP XCS Z81 XCS Z84 XCS Z83 XCS Z85
Weight (kg) 0.015 0.025 0.085 0.085
Separate componentsDescription Unit reference Weight
kg
Blanking plugs for operating head slot(Sold in lots of 10)
XCS Z29 0.005
(1) Blanking plug for operating head slot included with switch (3). Basic reference, to be completed: replace the dot by 2 for a 2 m long cable, by 5 for a 5 m long
cable or by 10 for a 10 m long cable. Example:XCS MP59LpbecomesXCS MP59L10 for a switch with a 10 m long cable.(2) Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch.
OG
OG/WH
BU/WH
BU
BU/WH
BU
OG/WH
OG
OG
OG/WH
BU/WH
BU
BN/WH
BN
BU/WH
BU
BN/WH
BN
OG/WH
OG
Dimensions:page 1/207
Schemes:page 1/209
References,characteristics
4
5
6
0
8/10/2019 xcsa
9/271/207
5
Safety detection solutions 2Guard switches, actuator operatedPlastic, xed head, type XCS MPPre-cabled, length 2 m, 5 m or 10 m
DimensionsXCS MP XCS Z81
(1) 7.6, length 2, 5 or 10 m.
XCS Z84
XCS Z83
(1) 2 elongated holes 4.2 x 6.
XCS Z85
(1) 2 elongated holes 4.2 x 6.
20
30
(1)
1 115
58
35
78
9
4.4
14
5.
6
3.
5
14 13.5
62
28.235.9
8.
4
2x4.32x9
5
33.8
14
3.
5
14
11.
6
34
8.4
4.3
25
34
=
=
=
15
=
28.213
8.
4
(1)
3.
5
25
34
=
=
=
15
=
28.213
8.
4
(1)
3.5
Characteristics:page 1/200
Dimensions
1
2
3
4
5
6
7
8
9
10
8/10/2019 xcsa
10/271/208
5
Safety detection solutions 2Guard switches, actuator operatedPlastic, xed head, type XCS MPPre-cabled, length 2 m, 5 m or 10 m
Operating radius required for actuatorXCS Z81 XCS Z84
XCS Z83 XCS Z85
Functional diagramsXCS MP59p XCS MP79p XCS MP70p XCS MP80p
Contact operation closed
open
R=930m
m
66.8
R=160m
m
66.8
R=230mm
36.4
R=16
0mm
36.4
R=50m
m
43.8
R=50m
m
43.8
R=50mm
43.8
R=50mm
43.8
BU-BU/WH
OG-OG/WH
5.2
5.5
28.2
5.2
28.2
BU-BU/WH
OG-OG/WH
BN-BN/WH
OG-OG/WH
BU-BU/WH
5.2
5.5
28.2
BN-BN/WHOG-OG/WH
BU-BU/WH
5.2
28.2
Setting-up,schemes
4
5
6
0
8/10/2019 xcsa
11/271/209
5
Safety detection solutions 2Guard switches, actuator operatedPlastic, xed head, type XCS MPPre-cabled, length 2 m, 5 m or 10 m
Schemes Note: These schemes are given as examples only, the designer must refer to the relevant safety standards for guidance.Wiring to PL=b, category 1 conforming to
EN/SO 13849-1
Wiring to PL=d, category 3 conforming to EN/ISO 13849-1
Example with 3-pole NC + NC + NO contact and protectionfuse to prevent shunting of the NC contact, either by cabledamage or by tampering.
(1) Signalling contact
Example with 2-pole NC + NO contact with mixed redundancy of the contacts and theassociated control relays.To activate K1, it is necessary to remove and re-insert the actuator when the supply is switched on.
Wiring to PL=e, category 4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508. Wiring method used in conjunction
with Preventa safety module (The guard switch should be used in conjunction with a safety limit switch to give electrical/mechanical redundancy).
Method for machines with quick rundown time (low inertia)Locking or interlocking device based on the principle of redundancy and self-monitoring.The safety modules ensure these functions.
Locking of actuator and operation in positive mode associated with a safety module
K1
F1
(1)
O
I
K1
BU/WH
BU
BN
BN/WH
OG
OG/WH
M
F1
K2
K1 K2
OG/WH
OG
BU/WH
BU
K1
K2
K1
KM1
O
I
KM2
K2
K1
KM1
KM2
M
XPS
XCS M
XCS MP
Schemes
1
2
3
4
5
6
7
8
9
10
8/10/2019 xcsa
12/271/210
5
Type of switch Without locking of actuator
References of switches without actuator ( NC contact with positive opening operation) with 1 or 2 cable entries tapped ISO M16 x 1.5
2-pole NC + NO (2)break before make,slow break 22
21
13
14
XCS PA592
2-pole NC + NO (2)snap action
22
21
13
14
XCS PA192
2-pole NO + NC (2)make before break,slow break 22
21
13
14
XCS PA692
2-pole NC + NC (2)slow break
11
12
21
22
XCS PA792
2-pole NC + NC (2)snap action
11
12
21
22
XCS PA292
3-pole NC + NO + NO (2)(2 NO staggered) slow break
33
34
22
21
13
14
XCS PA892 XCS TA592
3-pole NC + NO + NO (2)snap action
33
34
22
21
13
14
XCS PA392
3-pole NC + NC + NO (2)(NO staggered) slow break
32
31
13
14
22
21 XCS PA992 XCS TA792
3-pole NC + NC + NO (2)snap action
32
3
1
1
3
14
22
21
XCS PA492
3-pole NC + NC + NC (2)slow break
12
11
22
21
32
31 XCS TA892
Weight (kg) 0.110 0.160
References of switches without actuator ( NC contact with positive opening operation) with 1 or 2 cable entries tapped Pg 11 or 1/2" NPT
To order a switch with 1 or 2 cable entries for n 11 (Pg 11) cable gland (clamping capacity 7 to 10 mm), replace the last number (2) by 1in the selected reference.Example: XCS PA592 becomes XCS PA591.To order a switch with 1 or 2 cable entries for 1/2" NPT conduit (one n 11 tapped entry tted with metal adaptor DE9 RA1012), replace the last number (2) by 3 inthe selected reference. Example: XCA TA592 becomes XCS TA593.
Complementary characteristics not shown under general characteristics (page 1/200)
Actuation speed Maximum: 0.5 m/s, minimum: 0.01 m/s
Resistance to forcible withdrawal of actuator XCS PA, XCS TA:10 N (50 N using actuators XCS Z12or XCS Z13together with guardretaining device XCS Z21)
Mechanical durability XCS PA, XCS TA: > 1 million operating cycles
Maximum operating rate For maximum durability: 600 operating cycles per hour
Minimum force for positive opening u15 N
Cable entry XCS PA: 1 entry tapped M16 x 1.5 for ISO cable gland.XCS TA: 2 entries tapped M16 x 1.5 for ISO cable gland.
Materials Body and head: polyamide PA66, breglass impregnated
References of accessories
XCS Z91
809927
XCS Z200
DF523736
Description For use with Unit referenceWeight
kg
Blanking plugs for operating head slot
(Sold in lots of 10)XCS PA, XCS TA XCS Z28 0.050
Padlocking device to prevent insertionof actuator, for up to 3 padlocks
(padlocks not included)
XCS PA, XCS TA XCS Z91 0.053
Actuator centring device(3)
(Fixing screws included)
XCS PA, XCS TA XCS Z200 0.022
(1) Head adjustable in 90 steps throughout 360. Blanking plug for operating head slot included with switch.(2) Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head ofthe switch.
(3) Do not use with XCS Z91.
Other versions: please consult our Customer Care Centre.
Safety detection solutions 0Guard switches, actuator operatedPlastic, turret head(1), types XCS PA and XCS TA1 or 2 cable entries
References
4
5
6
0
8/10/2019 xcsa
13/271/211
5
Safety detection solutions 0Guard switches, actuator operatedPlastic, turret head, types XCS PA and XCS TA1 or 2 cable entries
References (continued),dimensions
References of actuators and guard retaining device
Description Straightactuator
Actuator with widexing (1)
Pivotingactuator
Right-angledactuator
Guard retainingdevice (2)
For guard switches XCS PA, TA XCS Z11 XCS Z12 XCS Z15 XCS Z13 XCS Z14 XCS Z21
Weight (kg) 0.015 0.015 0.012 0.085 0.025 0.080
(1) 2 actuator lengths, XCS Z12: L = 40 mm, XCS Z15: L = 29 mm.(2) Only for use with guard switches XCS PA and XCS TA (without actuator centring device XCS Z200) used in conjunction with actuators XCS Z12, XCS Z13 or
XCS Z15.
Dimensions
XCS PAp
91, XCS PAp
92 XCS PAp
93
34
30
93.5
39
307
30
20/22= =
13
.5
(1) 30
13.2
(1) 1 tapped entry for cable gland: 2 elongated holes 4.3 x 8.3 on 22 centres, 2 holes 4.3 on20 centres
(1) 1 tapped entry tapped for 1/2" NPT conduit: 2 elongated holes 4.3 x 8.3 on 22 centres, 2 holes 4.3 on 20 centres
XCS TAp9p Actuator centring device XCS Z200
1/2" NPT conduit adaptor M16 x 1.5 adaptor
DE9 RA1012 DE9 RA1016
(1) Tapped entry for 1/2" NPT conduit
(2) Pg 11 threaded shank
(1) M16 x 1.5 tapped entry
(2) Pg 11 threaded shank
(1) 2 tapped entries for cable gland or 1/2" NPT conduit adaptor(2) 2 elongated holes 4.3 x 8.3 on 22 centres, 2 holes 4.3 on
20 centres(3) 2 elongated holes 5.3 x 13.3
34
(1) 13.2
30
93.
5
39
20/22= =
30 30
30
7
29.
85
18
4
5.5
35.35
6.4
2 x 3
2 x 5.5
17.
4
6.
4
29.85
17.4
5.
8
39
20/22
52
40.3
114.5
12.5
12.5
30
30
(1)
(3)34
307
21
26
13(1)
24
References:page 1/210
Schemes:page 1/213
1
2
3
4
5
6
7
8
9
10
8/10/2019 xcsa
14/271/212
5
Safety detection solutions 0Guard switches, actuator operatedPlastic, turret head, types XCS PA and XCS TA1 or 2 cable entries
Dimensions (continued)XCS Z11 XCS Z12, XCS Z15
(1) Adaptor (included with actuator XCS Z11) for replacing, without drillingadditional xing hole, a guard switch XCK T with actuator XCK Y01 by aguard switch XCS TA with actuator XCS Z11.
a: 2 elongated holes 4.7 x 10 : 2 elongated holes 4.7 x 10
b: 1 elongated hole for M4 or M4.5 screw L = 40 mm (XCS Z12) or 29 mm (XCS Z15)
XCS Z13 XCS Z14
: 2 elongated holes 4.7 x 10 : 1 elongated hole 4.7 x 10
Operating radius required for actuator
XCS Z11 XCS Z12, XCS Z15
d = 46 mm (XCS Z12) or 35 mm (XCS Z15)
XCS Z13 XCS Z14
R = minimum radius
5
3765 2
4.
7
4.
7
12
22
15
13
12
22
15
L
2
26
==
2
13
40
=
=
55
11
6
55
66
28.5
52
6
27
13
35
=
=
32
26
23
2
5
42.5
2
26
42.
5
12
13
22
12
4.7
15
R=1500
R=1200
71 71
R=1500
R=1200
dd
R=300
R=150
72 72
R=1500
R=1200
48
48
References:page 1/210
Schemes:page 1/213
Dimensions (continued)
4
5
6
0
8/10/2019 xcsa
15/271/213
5
Safety detection solutions 0Guard switches, actuator operatedPlastic, turret head, types XCS PA and XCS TA1 or 2 cable entries
Setting-upFunctional diagrams
XCS PA1pp
XCS PA2pp
XCS PA3pp
XCS PA4pp
XCS PA5pp
,XCS TE5ppp XCS PA6pp
,XCS TE6ppp XCS PA7pp
,XCS TE7ppp XCS TA5pp
,XCS PA8pp XCS TA7pp
,XCS PA9pp
Contact operation
G Closed H Open G Unstable
Setting-up Schemes Note: These schemes are given as examples only, the designer must refer to the relevant safety standards for guidance.Functional diagrams Wiring to PL=b, category 1 conforming to
EN/ISO 13849-1
Wiring to PL=d, category 3 conforming to
EN/ISO 13849-1
XCS TA8pp
Example with 3-pole NC + NO + NO contact and protectionfuse to prevent shunting of the NC contact, either by cabledamage or by tampering.
Example with 2-pole NC + NO contact with mixed redundancy ofthe contacts and the associated control relays. To activate K1, it isnecessary to remove and re-insert the actuator when the supplyis switched on.
Contact operationG ClosedH OpenGUnstable
(1) Signalling contact.
Wiring to PL=e, category 4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508
Wiring method used in conjunction with safety module
(The guard switch should be used in conjunction with a safety limit switch to give electrical/mechanical redundancy)Method for machines with quick rundown time (low inertia)
Locking or interlocking device based on the principle of redundancy and self-monitoring.
The safety modules ensure these functions.
Locking of actuator and operation in positive mode associated with a safety module.
16
19
24
21-2213-1421-2213-14
16
19
24
11-1221-2211-1221-22
16
19
24
21-2213-1433-3421-2213-1433-34
16
19
24
21-2231-3213-1421-2231-3213-14
17
16
17.5
18.5
24
21-22
13-14
15
17
24
21-22
13-14
17
18.5
17
18.5
24
11-12
21-22
17
19
24
21-22
13-14
16
19
33-34
17
16
17.5
19
24
21-22
13-14
31-32
16.5
17
24
11-12
21-22
31-32
X
F1
(1)
O
I
X
22
21
13
14
33
34
M
F1
K2
K1 K2
14
13
22
21
K1
K2
K1
KM1
O
I
KM2
K2
K1
KM1
KM2
M
XPS
Setting-up, schemes
1
2
3
4
5
6
7
8
9
10
8/10/2019 xcsa
16/271/214
5
Safety detection solutions 3Guard switches, actuator operatedwith solenoid interlocking, turret headMetal, type XCS EPlastic, double insulated, type XCS TE
Presentation,characteristics
Metal, type XCS E Guard switches with locking of the actuator
Page 1/216
Plastic, type XCS LE Guard switches with locking of the actuator
Page 1/222
Environment characteristicsGuard switch type XCS E (metal) XCS TE (plastic)
Conformity to standards Products EN/IEC 60947-5-1, UL 508, CSA C22-2 n 14
Machine assemblies EN/IEC 60204-1, EN/ISO 14119
Product certifcations UL, CSA UL, CSA
Maximum safety level(1) PL=e, category 4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508
Reliability data B10d 5,000,000 (data value for a service life of 10 years can be limited by contact and mechanical wear)
Protective treatment Standard version: TC
Ambient air temperature For operation - 25+ 40C - 25+ 60C
For storage - 40+ 70C
Vibration resistance 5 gn (10500 Hz) conforming to EN/IEC 60068-2-6
Shock resistance 10 gn (duration 11 ms) conforming to EN/IEC 60068-2-27
Electric shock protection Class I conforming to EN/IEC 60536 Class II conforming to EN/IEC 60536
Degree of protection IP 67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1(2)
Cable entry 2 entries tapped ISO M20 x 1.5 (clampingcapacity 7 to 13 mm) or tapped for n 13(Pg 13.5) cable gland conforming toNFC 68-300 (clamping capacity 8 to 12 mm)or for 1/2" NPT (USAS B2-1) conduit
1 entry tapped M16 x 1.5 (clamping capacity4.5 to 10 mm) or tapped for n 11 (Pg 11) cablegland conforming to NFC 68-300 (clampingcapacity 7 to 10 mm) or for 1/2" NPT conduitusing metal adaptor DE9 RA1012 in n 11(Pg 11) tapped entry
Connecting cable 4 x 0.5 mm2
Materials Zamak case Polyamide PA66 breglass impregnated case
Actuators (all types): steel XC60, surface treated
(1) Using an appropriate and correctly connected control system.
(2) Live parts of these switches are protected against the penetration of dust and water.However, when installing take all necessary precautions to prevent the penetration of solidbodies, or liquids with a high dust content, into the actuator aperture. Not recommended foruse in saline atmospheres.
4
5
6
0
8/10/2019 xcsa
17/271/215
5
Safety detection solutions 3Guard switches, actuator operatedwith solenoid interlocking, turret headMetal, type XCS EPlastic, double insulated, type XCS TE
Characteristics (continued)
Contact block characteristicsRated operational characteristics 2 and 3 contact,
slow breakXCS E,XCS TE:aAC-15, B300: Ue = 240 V, Ie = 1.5 A or Ue = 120 V, Ie = 3 A
All models:cDC-13, Q300: Ue = 250 V, Ie = 0.27 A or Ue = 125 V, Ie = 0.55 A
conforming to EN/IEC 60947-5-1
Conventional thermal current in enclosure XCS E, XCS TE 2 and 3 slow break contact versions: Ithe = 6 A
Rated insulation voltage 2 and 3 contact 3 contact (XCS E), 2 contact (XCS TE):Ui = 500 V conforming to EN/IEC 60947-1; Ui = 300 V conforming to UL 508, CSA C22-2 n 14
Rated impulse withstand voltage 2 and 3 contact 3 contact (XCS E), 2 contact (XCS TE): Uimp = 6 kV conforming to EN/IEC 60947-5-1
Positive operation NC contacts with positive opening operation conforming to EN/IEC 60947-5-1, Section 3
Resistance across terminals y30 mWconforming to EN/IEC 60947-5-4
Short-circuit protection 2 and 3 contact 3 contact (XCS E), 2 contact (XCS TE): 10 A cartridge fuse type gG (gl)
Connection Screw clampterminals
2 and 3 contact 3 contact (XCS E), 2 contact(XCS TE):Clamping capacity, min: 1 x 0.5 mm2, max: 2 x 1.5 mm2with or without cable end
Complementary characteristicsActuation speed Maximum: 0.5 m/s, minimum: 0.01 m/s
Resistance to forcible withdrawal of actuator XCS E: 2000 N; XCS TE: 500 N
Mechanical durability XCS E: > 1 million operating cyclesXCS TE: 1 million operating cycles
Maximum operating rate For maximum durability: 600 operating cycles per hour
Minimum force for extraction of actuator u20 N
Materials Body and head: zamak (XCSE)Body and head: polyamide PA66, breglass impregnated (XCSTE)
Electrical durability
Conforming to EN/IEC 60947-5-1 Appendix C.Utilisation categories AC-15 and DC-13.Maximum operating rate: 3600 operating cycles/hour.Load factor: 0.5
3 contact XCS E and 2 contact XCS TE version, slow break
AC supply50/60 Hzaoinductive circuit
DC supplycPower broken in W for5 million operating cycles.
Voltage V 24 48 120
o W 13 9 7
Millionsofoperatingcycles
Current in A
0.5 1 2 3 4 5 100.1
0.2
0.5
1
5
2
43
Ithe
230 V 12/24/48 V
110 V
1
2
3
4
5
6
7
8
9
10
8/10/2019 xcsa
18/271/216
5
Safety detection solutions 3Guard switches, actuator operatedwith solenoid interlocking, turret head (1)
Metal, type XCS E, with 2 cable entries
Type of switch Locking on de-energisation and unlocking on energisation
of solenoid (2)
LED indication Orange LED: guard open signalling.Green LED: guard closed and locked signalling.
Supply voltage of solenoid aor 24 Vc(50/60 Hz ona)
aor48 Vc
(50/60 Hzona)
aor 110/120 Vc(3)(50/60 Hz ona)
aor 220/240 Vc(3)(50/60 Hz ona)
Type of contact on solenoid NO + NO 2 NC NC + NO NC + NO 2 NC NC + NO 2 NC
References of switches without actuator ( NC contact with positive opening operation) with 2 cable entries tapped ISO M20 x 1.5
3-poleNC + NO + NO (2 NO staggered)slow break(4)
33
34
22
21
13
14
XCS E5312 XCS E5322 XCS E5332 XCS E5342
3-poleNC + NC + NO (NO staggered)slow break(4)
32
31
13
14
22
21 XCS E7312 XCS
E73127 XCS E7332 XCS
E73327XCS E7342 XCS
E73427
3-poleNC + NC + NCslow break(4)
12
11
22
21
32
31 XCS E8312
(5)XCSE83127
(5)
XCS E8322(5)
XCS E8332 XCS E8342
Weight (kg) 1.140 1.140 1.140 1.140 1.140
References of switches with locking on energisation and unlocking on de-energisation
To order a guard switch with locking on energisation and unlocking on de-energisation of the solenoid, replace the 2nd number (3) by 5in the references shownabove. Example: XCS E5312 becomes XCS E5512.
References of switches with 2 cable entries tapped Pg 13.5 or 1/2" NPT
To order a switch with 2 cable entries for n 13 (Pg 13.5) cable gland:replace the last number (2) by 1in the selected reference. Example: XCS E5312 becomes XCS E5311.- for switches with 7 at the end of the reference, replace the 2 before the 7 by 1in the selected reference. Example: XCS E73127 becomes XCS E73117.To order a switch with 2 cable entries for 1/2" NPT conduit:- replace the last number (2) by 3in the selected reference. Example: XCS E5312 becomesXCS E5313.- for switches with 7 at the end of the reference, replace the 2 before the 7 by 3in the selected reference. Example: XCS E73127 becomes XCS E73137.
References of actuators (see page 1/222)
Solenoid characteristics
Load factor 100%
Rated operational voltage aorc24 V
aorc24 V
aorc48 V
aorc110/120 V
aorc220/240 V
Voltage limits Conforming to EN/IEC 60947-1 - 20%, + 10% of the rated operational voltage (including ripple onc)
Service life 20 000 hours
Consumption Inrush: 10 VA. Sealed: 10 VA
LED indicator characteristics
Rated insulation voltage 50 V conforming to EN/IEC 60947-1 250 V conforming to EN/IEC 60947-1
Current consumption 7 mA 7 mA
Rated operational voltage aor 24/48 Vc 110/240 Va
Voltage limits aor 20...52 Vc(including ripple) 95...264 Va(including ripple)
Service life 100,000 hours 100 000 hours
Protection against overvoltages Yes Yes
(1) Head adjustable in 90 steps throughout 360. Blanking plug for operating head slot included with switch.(2) A key operated lock (2 keys included with switch) enables forced opening of the interlocking mechanism, by authorised personnel, allowing withdrawal of theactuator and subsequent opening of the NC safety contacts.(3) For use on 110/120 Vcor 220/240 Vc, remove the LED indicator module.(4) Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch.(5) Switches supplied with a single green LED.
Other versions:please consult our Customer Care Centre.
References,characteristics
Dimensions:page 1/218
Schemes:page 1/219
4
5
6
0
8/10/2019 xcsa
19/271/217
5
Separate componentsDescription For use
withSupply voltage Reference Weight
kg
1 orange LED +1 green LED indicatormodule with cover +lock (1), seal and 4xing screws (2 keysincluded for lock)
XCS E73pp aor 24/48 Vc XCS Z43 0.175
Description For usewith
Key withdrawal positionsfrom lock
Unit reference Weightkg
Blanking plugs foroperating head slot(Sold in lots of 10)
XCS E XCS Z27 0.050
Keys for interlockforced openingdevice(Sold in lots of 10)
XCS E XCS Z25 0.100
Padlocking deviceto prevent preventinsertion of actuator,for up to 3 padlocks(padlocks not included)
XCS E XCS Z90 0.055
Description For use with Unit reference Weightkg
1/2" NPT conduitadaptor(Sold in lots of 5)
XCS E DE9 RA2012 0.048
M20 x 1.5 adaptor(Sold in lots of 5)
XCS E DE9 RA13520 0.010
(1) Lock incorporated as standard on guard switches XCS E: key withdrawal in LOCK andUNLOCK positions.
XCS Z4p
809848
809849
XCS Z90
809850
Safety detection solutions 0Guard switches, actuator operatedwith solenoid interlocking, turret headMetal, type XCS E, with 2 cable entries
References
1
2
3
4
5
6
7
8
9
10
8/10/2019 xcsa
20/271/218
5
Safety detection solutions 0Guard switches, actuator operatedwith solenoid interlocking, turret headMetal, type XCS E, with 2 cable entries
Dimensions
DimensionsGuard switchesXCS Epppp
98
26
33 3.5
95
12
43.5
6
113
88= =
48
33
146
38
7
16(1)
44
26
(1)
(1)
5.3
(1) 1 tapped entry for cable gland.
: 2 elongated holes 5.3 x 7.3
M20 x 1.5 adaptor 1/2" NPT conduit adaptor
DE9 RA13520 DE9 RA2012
19 28
24
21.3 (2)(1)
26
(1) M20 x 1.5 tapped entry
(2) Pg 13.5 threaded shank
(1) Tapped entry for 1/2" NPT conduit
(2) M20 x 1.5 threaded shank
References:page 1/216
4
5
6
0
8/10/2019 xcsa
21/271/219
5
Safety detection solutions 0Guard switches, actuator operatedwith solenoid interlocking, turret headMetal, type XCS E, with 2 cable entries
Setting-up,schemes
Setting-upFunctional diagrams
XCSp
5ppp
XCSp
7ppp
XCSp
8ppp
Contact operation
GClosed
HOpen
GUnstable
Schemes Note: These schemes are given as examples only, the designer must refer to the relevant safety standards for guidance.Wiring to PL=b, category 1 conforming toEN/ISO 13849-1
Wiring to PL=d, category 3 conforming to
EN/ISO 13849-1
Example with 3-pole NC + NO + NO contact and protectionfuse to prevent shunting of the NC contact, either by cabledamage or by tampering.
Example with 3-pole NC + NO + NO contact with mixed redundancy of the contacts and theassociated control relays. To activate K1, it is necessary to remove and re-insert the actuatorwhen the supply is switched on.
(1) Signalling contact H1: actuator not inserted indicator
Wiring to PL=e, category 4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508. Wiring method used in conjunction
with Preventa safety module (The guard switch should be used in conjunction with a safety limit switch to give electrical/mechanical redundancy).
Method for machines with long rundown time (high inertia)
Interlocking device for actuator tted on guard and zero speed detection.
23
21
22.5
25
31
21-22
13-14
33-34
23
21.5
22
25
31
21-22
31-32
13-14
23
25
31
11-12
21-22
31-32
X
F1
O
I
X
22
21
13
14
33
34
M
(1)
F1
K2
K1 K2
14
13
34
33
22
21
K1
K2
K1
KM1
O
I
KM2
H1
K2
K1
KM1
KM2
M
XPS
XPS
VNE
References:page 1/216
Dimensions:page 1/218
1
2
3
4
5
6
7
8
9
10
8/10/2019 xcsa
22/271/220
5
Safety detection solutions 0Guard switches, actuator operatedwith solenoid interlocking, turret headMetal, type XCS E, with 2 cable entries
Schemes
Wiring to PL=b, category 1 conforming to EN/ISO 13849-1
Wiring examples with protection fuse to prevent shunting of the NC contact, either by cable damage or by tampering.
Locking on de-energisation, NC + NO + NO Locking on energisation, NC + NO + NO
XCS E53pp XCS E55pp
(1) Solenoid (1) Solenoid
(2) Auxiliary contact (2) Auxiliary contact
E1-E2: Solenoid supply E1-E2: Solenoid supply
43-44: Solenoid signalling contact 51-52: Solenoid signalling contact
13-14: Safety contact, available for redundancy 13-14: Safety contact, avai lable for redundancy
33-X1: LED (orange): actuator withdrawn 33-X1: LED (orange): actuator withdrawn
51-X1: LED (green): actuator inserted and locked 43-X1: LED (green): actuator inserted and locked
21-52: Safety pre-wiring obligatory 21-44: Safety pre-wiring obligatory
X
O
I
X
21
F1
22
51
52
1413
3433
X3
X1
X2O G G N
M
E2
E1
44
43
(1)
(2)
X
O
I
X
21
F1
22
51
52
1413
3433
X3
X1
X2O G G N
M
E2
E1
44
43
(1)
(2)
References:page 1/216
Dimensions:page 1/218
4
5
6
0
8/10/2019 xcsa
23/271/221
5
Safety detection solutions 0Guard switches, actuator operatedwith solenoid interlocking, turret headMetal, type XCS E, with 2 cable entries
Schemes
Wiring to PL=d, category 3 conforming to EN/ISO 13849-1
Wiring examples with redundancy for the guard switch contacts, without monitoring or redundancy in the power circuit
Locking on de-energisation, NC + NC + NO Locking on de-energisation, NC + NC + NO
XCS E73pp XCS E73pp7
(1) Solenoid (1) Solenoid
(2) Auxiliary contact (2) Auxiliary contact
E1-E2: Solenoid supply E1-E2: Solenoid supply
43-44: Solenoid signalling contact 41-42 and 51-52: Solenoid signalling contacts
21-22 and 31-32: Safety contacts, available for redundancy 21-22 and 31-32: Safety contacts, available for redundancy
13-X1: LED (orange): actuator withdrawn 13-X1: LED (orange): actuator withdrawn
51-X1: LED (green): actuator inserted and locked 51-X1: LED (green): actuator inserted and locked
21-52: Safety pre-wiring obligatory 21-52 and 42-31: Safety pre-wiring obligatory
Locking on energisation, NC + NC + NO
XCS E75pp
(1) Solenoid
(2) Auxiliary contact
E1-E2: Solenoid supply
51-52: Solenoid signalling contact21-22 and 31-32: Safety contacts, available for redundancy
13-X1: LED (orange): actuator withdrawn
43-X1: LED (green): actuator inserted and locked
21-44: Safety pre-wiring obligatory
K1 K2
21
F1
22
51
52
3231
1413
X3
X1
X2OG GN
E2
E1
44
43
(1)
(2)
KM2
O
I
KM1
KM2
K1
K2
F2
M
KM1
K1 K2
21
F1
22
51
52
3231
1413
X3
X1
X2OG GN
E2
E1
42
41
(1)
(2)
KM2
O
I
KM1
KM2
K1
K2
F2
M
KM1
KM2
O
I
K1 K2
KM1
KM2
21
F1
22
51
52
32 K1
K2
31
1413
X3
X1
X2OG GN
E2
E1
44
43
F2
(1)
(2)
M
KM1
References:page 1/216
Dimensions:page 1/218
1
2
3
4
5
6
7
8
9
10
8/10/2019 xcsa
24/271/222
5
References,
characteristics (continued)
Type of switch Locking on de-energisation and unlocking on energisation of solenoid (2)
Supply voltage of solenoid aor 24 Vc(50/60 Hz ona) aor 120 Vc(50/60 Hz ona) aor 230 Vc(50/60 Hz ona)
References of switches without actuator ( NC contact with positive opening operation)
with 1 cable entry tapped ISO M16 x 1.5 (2)2-pole NC + NC(3)break before make,slow break 22
21
13
14
XCS TE5312 XCS TE5332 XCS TE5342
2-pole NO + NC (3)make before break,slow break 22
21
13
14
XCS TE6312 XCS TE6332 XCS TE6342
2-pole NC + NC(3)slow break1
1
12
2
1
22
XCS TE7312 XCS TE7332 XCS TE7342
Weight (kg) 0.360 0.360 0.360
References of switches with locking on energisation and unlocking on de-energisationTo order a guard switch with locking on energisation and unlocking on de-energisation of the solenoid, replace the 2 ndnumber (3) by5. Example: XCS TE5312becomes XCS TE5512.
References of switches with 1 cable entry tapped Pg 11 or 1/2" NPTTo order a switch with 1 cable entry for n 11 (Pg 11) cable gland, replace the last number (2) by 1in the selected reference.Example: XCS TE5312 becomes XCS TE5311.To order a switch with 1 cable entry for 1/2" NPT (USAS B2-1) conduit, replace the last number (2) by 3in the selected reference.Example: XCS TE5312 becomes XCS TE5313. The n 11 (Pg 11) tapped entry is tted with metal adaptor DE9 RA1012 for 1/2" NPT conduit.
Solenoid characteristicsLoad factor 100%
Rated operational voltage aor 24 Vc aor 120 Vc aorc230 V
Voltage limits - 20%, +10% of the rated operational voltage (including ripple onc) conforming toEN/IEC 60947-1
Service life 20 000 hours
Consumption 10 VA max.
References of actuators and guard retaining device
Description Straight actuator Actuator with wide xing (4) Pivoting actuator Right-angled actuator
For guard switches XCS E and XCS TE XCS Z11 XCS Z12 XCS Z15 XCS Z13 XCS Z14
Weight (kg) 0.015 0.015 0.012 0.085 0.025
References of accessoriesDescription For use
withUnit reference Weight
kg
Blanking plugs for operating head slot(Sold in lots of 10)
XCS TE XCS Z28 0.050
Tool for forced opening of interlockingdevice(Sold in lots of 10)
XCS TE XCS Z100 0.050
Padlocking device to prevent insertionof actuator, for up to 3 padlocks(padlocks not included)
XCS TE XCS Z91 0.053
Actuator centring device (5)(Fixing screws included)
XCS TE XCS Z200 0.022
1/2" NPT conduit adaptor(Sold in lots of 10)
XCS TE DE9 RA1012 0.048
M16 x 1.5 adaptor(Sold in lots of 10) XCS TE DE9 RA1016 0.048
(1) Head adjustable in 90 steps throughout 360. Blanking plug for operating head slot included with switch.(2) A special tool included with the guard switch enables forced opening of the interlocking mechanism, by authorised personnel, allowing withdrawal of the actuator andsubsequent opening of the NC safety contacts.(3) Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch.(4) 2 actuator lengths, XCS Z12: L = 40 mm, XCS Z15: L = 29 mm.(5) Do not use with XCS Z91.
Other versions: please consult our Customer Care Centre.
XCS Z91
809927
XCS Z200
DF523736
Safety detection solutions 3Guard switches, actuator operatedwith solenoid interlocking, turret head (1)Plastic, type XCS TE, with 1 cable entry
Dimensions:page 1/223
Schemes:page 1/225
4
5
6
0
8/10/2019 xcsa
25/271/223
5
Dimensions (continued)
DimensionsGuard switches Actuator centring deviceXCS TEpppp
XCS Z200
1/2" NPT conduit adaptor M16 x 1.5 adaptor
DE9 RA1012 DE9 RA1016
(1) Tapped entry for 1/2" NPT conduit
(2) Pg 11 threaded shank
(1) M16 x 1.5 tapped entry
(2) Pg 11 threaded shank
(1) 1 tapped entry for cable gland: 2 elongated holes 4.3 x 8.3 on 22 centres, 2 holes 4.3 on 20 centres
21
26
13(1)
24
ActuatorsXCS Z11 XCS Z12, XCS Z15
(1) Adaptor (included with actuator XCS Z11) for replacing, without drillingadditional xing hole, a guard switch XCK T with actuator XCK Y01 by aguard switch XCS TA with actuator XCS Z11.
a: 2 elongated holes 4.7 x 10 : 2 elongated holes 4.7 x 10
b: 1 elongated hole for M4 or M4.5 screw L = 40 mm (XCS Z12) or 29 mm (XCS Z15)
XCS Z13 XCS Z14
: 2 elongated holes 4.7 x 10 : 1 elongated hole 4.7 x 10
5
3765 2
4.
7
4.7
12
22
15
13
12
22
15
Adaptor shank (1)
L
2
26
==
2
13
40
=
=
55
11
6
55
66
28.5
5
2
6
27
13
35
=
=
32
26
23
2
5
42.5
2
26
42.
5
12
13
22
12
4.7
15
References:page 1/222
Safety detection solutions 3Guard switches, actuator operatedwith solenoid interlocking, turret headPlastic, type XCS TE, with 1 cable entry
29.
85
18
4
5.5
35.35
6.4
2 x 3
2 x 5.5
17.
4
6.
4
29.85
17.4
5.8
38
(1)
33
14.5
7
30
20/22 4
110
43
15
93.5
40
1
2
3
4
5
6
7
8
9
10
8/10/2019 xcsa
26/271/224
5
Safety detection solutions 3Guard switches, actuator operatedwith solenoid interlocking, turret headPlastic, type XCS TE, with 1 cable entry
Setting-up,schemes
Operating radius required for actuator
XCS Z11 XCS Z12, XCS Z15
d = 46 mm (XCS Z12) or 35 mm (XCS Z15)
XCS Z13 XCS Z14
R = minimum radius
R=1500
R=1200
71 71
R=1500
R=1200
dd
R=300
R=150
72 72
R=1500
R=1200
48
48
Setting-up Schemes
Functional diagrams Wiring to PL=d, category 3 conforming to EN/ISO 13849-1XCS TE5ppp XCS TE6ppp XCS TE7ppp Example with 2-pole NC + NO contact with mixed redundancy of the contacts
and the associated control relays. To activate K1, it is necessary to remove andre-insert the actuator when the supply is switched on.
Contact operation
GClosed
HOpen
GUnstable
Schemes (continued)Wiring to PL=e, category 4 conforming to EN/ISO 13849-1
and SIL 3 conforming to EN/IEC 61508
(The guard switch should be used in conjunction with a safety limit switch togive electrical/mechanical redundancy)
Method for machines with long rundown time (high inertia)
Interlocking device for actuator tted on guard and zero speed detection.
17
16
17.5
18.5
24
21-22
13-14
15
17
24
21-22
13-14
17
18.5
17
18.5
24
11-12
21-22
F1
K2
K1 K2
14
13
22
21
K1
K2
K1
KM1
O
I
KM2
K2
K1
KM1
KM2
M
XPS
XPS
VNE
(1) These schemes are given as examples only, the designer must refer to the relevant safety standards for guidance.
4
5
6
0
8/10/2019 xcsa
27/27
5
Safety detection solutions 3Guard switches, actuator operatedwith solenoid interlocking, turret headPlastic, type XCS TE, with 1 cable entry
Schemes
Schemes (continued)Wiring to PL=b, category 1 conforming to EN/ISO 13849-1
Wiring examples with protection fuse to prevent shunting of the NC contact, either by cable damage or by tampering.Locking on de-energisation Locking on energisation
NC + NO
XCS TE53pp
NC + NO
XCS TE55pp
(1) Solenoid (1) Solenoid
(2) Auxiliary contact (2) Auxiliary contact
E1-E2: Solenoid supply E1-E2: Solenoid supply
13-14: Safety contact, available for redundancy or signall ing 13-14: Safety contact, available for redundancy or signall ing
Wiring to PL=d, category 3 conforming to EN/ISO 13849-1
Wiring examples with redundancy for the guard switch contacts, without monitoring or redundancy in the power circuit
Locking on de-energisation Locking on energisation
NC + NC
XCS TE73pp
NC + NC
XCS TE75pp
(1) Solenoid (1) Solenoid
(2) Solenoid auxiliary contact (2) Solenoid auxiliary contact
E1-E2: Solenoid supply E1-E2: Solenoid supply
11-12: Safety contact, available for redundancy 11-12: Safety contact, available for redundancy
E2 31 33E1
F1
(32) 21 22
1413
X
X
M
O
I
(1)
(2)
E2 31 33E1
F1
(2) (34)
(1)
21 22
1413
X
X
M
O
I
E 2 3 1 3 3E1
F1
(2) (32)
(1)
21 22
1211
K1 K2
KM2
O
I
KM1
KM2
K1
K2
F2
M
KM1
E2 31 33E1
F1
(2) (34)
(1)
21 22
1211
K1 K2
KM2
O
I
KM1
KM2
K1
K2
F2
M
KM1
1
2
3
4
5
6
7
8
9
10