AIR TO WATER HEAT PUMPSHot water and comfortable ambient temperature all year round
OUR MISSION IS TO MAKE THE WORLD A BETTER PLACE
HEAT PUMP PRINCIPLE
CARRIER.A UNITED TECHNOLOGIES COMPANY
The EU is committed to reducingts overall emissions to at least 20%
below 1990 levels by 2020, and iseady to scale up this reduction to
as much as 30% under a new global climate change agreement when other developed countries make comparable efforts.It has also set itself the target of increasing the share of renewablesin energy use to 20% and increaseenergy efficiency by 20% before 2020.
REDUCE CO2 EMISSIONS WITH ENERGYEFFICENT SOLUTIONSHeat pumps use mainly ambient air for the production of domestic heating. This source of renewable energy reduce the overall energy consumption and minimize the amount of CO2 emissions.
In recognition of our commitment to developingproducts for a safer, cleaner and less polluted planet, Carrier received the prestigious OzoneProtection Award (EPA).
Tt
breacocIt
3 kW RENEWABLE ENERGY
1 kW ELECTRICITY
+
=4 kW
HEATING POWER
Whether you need air conditioning for a new building ora refurbishment project, for a commercial centre, an officeapplication or an industrial process, Carrier can offer you awide range of solutions to meet your needs – from liquidchillers/heat pumps, fan coil solutions, air treatment/handling solutions right through to standard and tailor-made system controls.Carrier provides heating, ventilating and air conditioningsolutions for optimised individual customer comfort.
IMPROVE THE ENERGY USE IN YOUR HOME
refrigerant2 CARRIER HEATING SYSTEMS 3
HEAT PUMP
HYDRONIC MODULE SANITARY HOT WATER TANKThe hot water stored in the tank is kept in emperature using the heat generated byhe heat pump. The electrical heating is used
only whenever there is a peak request for hot water.Different tank type size are available to adapt to any domestic need. With theanti-legionella feature included the system will periodically heat over 70°C to preventbacteria formation.
FAN COILSTerminal fan coil distribute the heat or coldair in the ambient. Its fan speed can be egulated to match user personal needs.
SOLAR PANEL
RADIATORSExisting low temperature radiators can beused with heat pump heating system.The electronic control of the module keep he temperature constant avoiding heating
peaks and heat waste.
CONTROLThe user friendly interface is placed in thehydronic module. Provide triple function,nstallation parameters and setpoints,
user selectable programs and scheduledoperation, system monitoring and self check diagnosis.
SWIMMING POOL HEATERHeat pumps have spare capacity available in the intermediate season which can be used to heat aswimming pool without altering the comfort in the house. This heat exchanger is designed to recover thiscapacity.
EuTtp
Tare
Thn
uod
THE IDEAL SOLUTIONXP Energy heat pump system is designed to satisfy different applications (new houses or renovation) and different conditions (one zone, two zone, sanitary hot water production).
UNDER FLOOR HEATINGWater circuit run in underfloor pipes.With this system heat energy (radiantheat and heat conduction) is diffused evenly in the indoor. Using the heatpump in cooling mode the same circuit
o cool the indoor ambient in summer period.
WWhep
ttohDaawb
4 CARRIER HEATING SYSTEMS 5
INVERTER DRIVEN TECHNOLOGYThe advance electronic management of the compressor operation enable consistent energy savings compared to a traditional fixed speed system:
FLOATING SETPOINT
SOFT START
TEMPERATURE CONTROL
HIGH COP IN PART LOAD
INVERTER
FIXED SPEED
g p
ENERGY SAVINGSSize the system based on the temperature condition in your area. You’ll be able to calculate upfront the savings on your energy bills and the time needed to fully recover your investment.
TAX REDUCTION AND INCENTIVE
Yearly distribution of outdoor air temperature in number of hours
LONDON
FRANKFURT
ROME
ATHENS
KRAKOW
STOCKHOLM
-3° -5°
-7°
-3°
-10°-15°
-15°
-7°-5°
-3°PARIS
MADRID
6 CARRIER HEATING SYSTEMS 7
HEATING
COOLING
HOT WATER
INVERTER HEAT PUMP HYDRONIC MODULE
INVERTER HEAT PUMP
HYDRONIC HYDRONMODULE
R INTERFACE
USER INTERFACE
SANITARY WATER TANK
SANITARY WATER TANK
Buffer tank
25lt
VERTER HEAT PUMP
INVERTER HEAT PUM
SINGLE ZONE SYSTEM up to 6,5 kW
TWO ZONES SYSTEM up to 11,5 kW
Emitters type SINGLE ZONE
Emitters type FIRST ZONE
Emitters type SECOND ZONE
ULTRA PRECISE TEMPERATURE CONTROLConversely to standard thermostat that cannot avoidtemperature fluctuation. Carrier have developed and adaptive control which calculate also the inertia of the building.Its powerful software elaborate the signals coming from the sensors and adjust the operating parameters accordingly.The result is the optimal room temperature maintainedconstantly in every condition.
Standard Thermostat
Carrier Thermostat control
Indoor heating inertia is not considered
Temperature is continuosily controlled and regulated
TOTAL COMFORT SOLUTIONEnjoy the comfortable well being in every season, using less energy and with the personal satisfaction of helping to preserve our delicate environment.
YDRONIC MODU
E
UNIQUE IN THE MARKET
FLOOR
FLOOR
FLOOR
FAN COIL
FAN COIL
FAN COIL
RADIATOR
RADIATOR
RADIATOR
FAN COIL
FAN COIL
FAN COIL
ADIATOR
ADIATOR
ADIATOR
Low or medium temperature
Low temperature
8 CARRIER HEATING SYSTEMS 9
THE RIGHT SYSTEMThe XP Energy heat pump solution is a cost effective choice in the long run, even in the areas with low temperature in winter time. In these condition the heat pump operation, depending on the type of system installed can be: Mono-energetic or bi-valent.
THE ADVANTAGES OF THE LOW TEMPERATUREUsing low temperature emitters increases the efficiency of the system. As you can see in the graph the performance of the Heat pump (COP) is not constant. It is measured at arating point for system reference, but it increases when the temperature of the water circulating in the system is low.
Therefore by selecting a low temperature emitter like the Carrier fan coils you’ll increase the efficiency, reduce theenergy consumption and shorten the overall pay back time.
45°C LWT
35°C LWT
55°C LWT
1,0 2,0 3,0 4,0
9 kW unit at 7°C Outdoor temperature
MONOENERGETIC SYSTEM
BIVALENT SYSTEM
Carrier XP Energy Two zone system gives the possibilityto distribute the water at different temperature, basedon the emitters demand and the signals coming from the temperature sensors.
All year round the highest COP, due to thelowest LWT
10 CARRIER HEATING SYSTEMS 11
INVERTER TECHNOLOGYADVANCED SYSTEM ELECTRONIC MANAGEMENTTwo distinct electronic management logics optimiseindividual well-being with minimum energy consumption:
Pulse Amplitude Modulation (PAM) of direct current togenerate maximum power for the compressor at start-up and in peak load conditions.
Pulse Width Modulation (PWM) of direct current optimises compressor efficiency once the preset temperature hasbeen reached, ensuring optimum comfort while savingenergy.
XP Energy hydronic module ensures a high level of comfort and energy saving.
It is designed to fit in a standard kitchen cabinet.
Its main functions is to integrate different components,including the possibility to connect solar panels.
The electronic control manage two independenttemperature zone with their own programmable temperature settings. Calculates also the thermal inertia of the house as well as the evolution of the outdoor airtemperature to create the required level of comfort.
The two zone hydro module includes a 25 liters buffer tank.
USER INTERFACE
ECOCOMFORTDC TWINROTARY COMPRESSOR
Two rotary compression cylinders, offset from each other by 180°, and a DC brushless motor with the shaft in perfect balance are used to reduce vibration and noise, even whenoperating at very low speeds.
LONG PIPE RUNS AND FLEXIBLE INSTALLATIONOutdoor units have long pipe runs (up to 70 m) and pipe elevation (30 m) therefore can be placed in the best suitable spot of your home, without affectign the systemperformance.
LOWAMBIENT PERFORMANCEFor the comfort of end-users, these heat pumps can work in extreme temperature conditions from –15 °C to 46 °C outdoor temperature.
ACCESSORIES
Heat exchanger control for swimming pool heating
Accumulative water tank for sanitary hot water production
Thermodynamic hot water tank (with heat pump) forsanitary water production
CONDENSING UNIT
HYDRONIC MODULE
LOW SOUND LEVELSXP Energy systems are very quiet. The outdoor units components drastically reduce anypossible noise: fully insulated compressor, twin rotary cylinder shaft, component vibration suppression, fan design.
VERY QUIET QUIET DISTURBING
12 CARRIER HEATING SYSTEMS 13
CARRIER HEATING SYSTEMS
Air to water split system Heating only Heating and cooling
Indoor unit 80AW1--H 80AW1--H 80AW2--H 80AW2--H 80AW1--X 80AW1--X 80AW2--X 80AW2--X
Outdoor unit (HP) 38AW050H7 38AW065H7 38AW090H7 38AW115H7 38AW050H7 38AW065H7 38AW090H7 38AW115H7
Nominal cooling capacity kW - - - - 4,23 5,59 7,88 9,00
Minimum cooling capacity kW - - - - 0,76 1,03 2,15 2,46
Maximum cooling capacity kW - - - - 5,62 7,55 11,4 13,02
Nominal power input kW - - - - 1,16 1,53 1,95 2,37
E.E.R. W/W - - - - 3,65 3,65 4,05 3,80
Energy efficiency class (cooling mode) - - - - A A A A
Nominal heating capacity kW 5,00 6,53 9,10 11,50 5,00 6,53 9,10 11,50
Minimum heating capacity kW 1,17 0,86 1,61 1,77 1,17 0,86 1,61 1,77
Maximum heating capacity kW 5,86 8,81 14,75 15,43 5,86 8,81 14,75 15,43
Nominal power input kW 1,13 1,51 2,07 2,71 1,13 1,51 2,07 2,71
C.O.P. W/W 4,41 4,32 4,40 4,24 4,41 4,32 4,40 4,24
Energy efficiency class (heating mode) A A A A A A A A
Outdoor unit (HP) 38AW050H7 38AW065H7 38AW090H7 38AW115H7
Compressor type Twin Rotary Twin Rotary Twin Rotary Twin Rotary
Maximum pipe length m 50 30 70 70
Maximum height difference m 30 30 30 30
Chargeless m 20 20 30 30
Air flow (min / max) l/sec 728 783 1658 1767
Air flow (min / max) m3/h 2620 2820 5970 6360
Sound pressure (cooling mode) dB(A) 44 45 48 50
Sound power (cooling mode) dB(A) 64 65 68 70
Sound pressure (heating mode) dB(A) 44 48 49 50
Sound power (heating mode) dB(A) 64 68 69 70
Dimensions (h × l × d) mm 690 × 900 × 320 820 × 900 × 320 1360 × 900 × 320 1360 × 900 × 320
Weight kg 49 51 88 88
Flare connections in 1/4” – 1/2” 3/8” – 5/8” 3/8” – 5/8” 3/8” – 5/8”
Power supply V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50
OUTDOOR UNIT (air temperature) INDOOR UNIT (water temperature)
COOLING HEATING COOLING HEATING
max min max min max min max min
45 °C db 5 °C db30 °C db –15 °C db
18 °C 4 °C 55 °C 20 °C24 °C wb –17 °C wb
Hydronic module matched with CDU 5 kW and 6,5 kW
Indoor unit 80AW100H 80AW100X 80AW102H 80AW102X 80AW104H 80AW104X 80AW106H 80AW106X
Electric heater kW - - 2 2 4 4 6 6
Electrical heaters back up kW - - 1 × 2 1 × 2 2 × 2 2 × 2 2 × 3 2 × 3
Maximum comfort zones number 1 1 1 1 1 1 1 1
Heater capacity, kW 1,0 1,0 1,2 1,2 1,4 1,4 1,6 1,6
Boiler back up connection - - - - - - - -
Heating only yes yes yes yes yes yes yes yes
Heating and cooling yes yes yes yes yes yes yes yes
Reversible - yes - yes - yes - yes
Domestic hot water production Option Option Option Option Option Option Option Option
Hydronic module matched with CDU 9 kW and 11,5 kW
Indoor unit 80AW200H 80AW200X 80AW204H 80AW204X 80AW206H 80AW206X 80AW208H 80AW208X
Electric heater kW - - 4 4 6 6 8 8
Electrical heaters back up kW - - 2 × 2 2 × 2 2 × 3 2 × 3 2 × 4 2 × 4
Maximum comfort zones number 2 2 2 2 2 2 2 2
Heater capacity, kW 2,0 2,0 2,4 2,4 2,6 2,6 2,8 2,8
Boiler back up connection yes yes - - - - - -
Heating only yes yes yes yes yes yes yes yes
Heating and cooling yes yes yes yes yes yes yes yes
Reversible - yes - yes - yes - yes
Domestic hot water production Option Option Option Option Option Option Option Option
CC
BB
A
A
A
C
B
A B C
38AW050H7 mm 900 690 320 49
38AW065H7 mm 900 820 320 51
38AW090H7 mm 900 1360 320 88
38AW115H7 mm 900 1360 320 88
A B C
80AW1--- mm 580 780 360 40
80AW2--- mm 560 1050 522 80
Indoor unit 80AW1--- 80AW2---
Outdoor unit 38AW050H7 38AW065H7 38AW090H7 38AW115H7
Nominal water flow lt/h 860 1118 1548 1978
Minimum water flow lt/h 688 894 1238 1582
Maximum water flow lt/h 1032 1342 1358 2374
Sound power (cooling mode) dB(A) 27 27
Sound power (heating mode) dB(A) 27 27
Dimensions (h × l × d) mm 780/580/360 1050/560/522
Weight kg 40 80
Power supply V-ph-Hz 230-1-50 230-1-50
System size Boiler backupElectric heater
0 kW 2 kW 4 kW 6 kW 8 kW
50 - yes yes yes - -
65 - yes yes yes - -
90 yes yes - yes yes yes
115 yes yes - yes yes yes
Code Description
80AW9009 Accumulative hot water tank for sanitary water production
80AW9010 Thermodynamic hot water tank (with heat pump) for sanitary water production
80AW9011 Heat exchanger plus control for swimming pool heating
80AW9019 Electronic mixing valve zoning kit
80AW9020 Direct zoning kit
A
B
C
14 CARRIER HEATING SYSTEMS 15
www.carrier.com
Sept
embe
r 200
9 –
The
man
ufac
ture
r res
erve
s th
e rig
ht to
cha
nge
the
prod
uct s
peci
ficat
ions
, dat
a an
d im
ages
with
out n
otic
e.