Magna-Power Electronics • Programmable DC Power Supplies10
XR Series: 2 kW to 10 kW
OverviewMagna-Power Electronics XR Series was designed from the ground up for high reliability and industry leading 2U (3.5” height) rack-mount power density, with output isolation for units rated up through 2000 Vdc. This product series utilizes Magna-Power Elec-tronics signature current-fed power processing, delivering robust power conversion with a high power factor—greater than 0.92 for 3Φ units. Soft-start circuitry on the input minimizes in-rush current to levels below the rated input current. High accuracy programming and monitoring levels allow confidence in power supply measure-ments, eliminating the need for external power meters.
All XR Series power supplies come standard with isolated 37-pin ex-ternal I/O, RS232, Remote Interface Software, IVI drivers for integra-tion into a variety of programming environments, and modulation capabilities for non-linear output profile emulation. Two front panel types are available for different application requirements. The stan-dard XR Version front panel (pictured in the image above) provides front panel control knobs and calibration, start and stop buttons, and a digital display for voltage and current. The C Version front panel provides a blank display panel, allowing control only from the computer or isolated 37-pin I/O connection.
Available Options• 208/240 Vac Single-Phase Input (SP) (2 kW Only)• Cabinet and Integrations (+CAB1, +CAB2, +CAB3)• High Slew Rate Output (+HS)• IEEE-488 GPIB Interface (+GPIB)• LXI TCP/IP Ethernet Interface (+LXI)• Photovoltaic Power Profile Emulation (+PPPE)• RS-485DSS Interface (External) (+RS485)• UID47: Universal Interface Device (+UID)• USB Edgeport Interface (External) (+USB)
XR Series 2 kW, 4 kW, 6 kW, 8 kW, and 10 kW
(15) XR Series Power Supplies with +CAB3 Option
Product Name: XR Series
Number of Models: 126
Power Levels: 2 kW, 4 kW, 6 kW, 8 kW, and 10 kW
Voltage Range: Models from 0-5 Vdc to 0-10000 Vdc
Current Range: Models from 0-2.0 Adc to 0-600 Adc
Enclosure Rack-mount, 2U
www.magna-power.com 11
2U Programmable DC Power Supplies
Input Specifications
Nominal Voltage3 phase, 3 wire + ground
208 Vac, 3Φ (operating range 187 - 229 Vac)240 Vac, 3Φ (operating range 216 - 264 Vac) 380 Vac, 3Φ (operating range 342 - 418 Vac)415 Vac, 3Φ (operating range 373 - 456 Vac)440 Vac, 3Φ (operating range 396 - 484 Vac)480 Vac, 3Φ (operating range 432 - 528 Vac)
1 phase, 2 wire + ground (2 kW Models Only)
208 Vac, 1Φ (operating range 187 - 229 Vac)240 Vac, 1Φ (operating range 216 - 264 Vac)
Frequency 50 Hz - 400 Hz (operating range 45 - 440 Hz)
Power Factor > 0.92 at maximum power for 3Φ units > 0.70 at maximum power for 1Φ units
Output Specifications
Ripple (See Models Chart)
Line Regulation Voltage Mode: ± 0.004% of full scaleCurrent Mode: ± 0.02% of full scale
Load Regulation Voltage Mode: ± 0.01% of full scaleCurrent Mode: ± 0.04% of full scale
Load Transient Response 2 ms to recover within ±1% of full scale output, with a 50% to 100% or 100% to 50% step load change
Efficiency ≥ 86% at full load (See Model Charts)
Stability ± 0.10% for 8 hrs. after 30 min. warmup
Isolation User inputs and outputs: referenced to earth ground
Maximum input voltage to ground: ±2500 Vac
Maximum output voltage to ground: • Models ≤1000 Vdc: ±1000 Vdc• Models >1000 Vdc and ≤2000 Vdc: ±(2000 Vdc + Vo/2)• Models >2000 Vdc: No output isolation, specify positive or negative output polarity
Maximum Slew Rate Standard Models,1000 Vdc and below:100 ms for output voltage change from 0 to 63%100 ms for output current change from 0 to 63%
With High Slew Rate Option (+HS) and models >1000 Vdc:4 ms for output voltage change from 0 to 63%8 ms for output current change from 0 to 63%
Bandwidth Standard Models,1000 Vdc and below:3 Hz for remote analog voltage programming2 Hz for remote analog current programming
With High Slew Rate Option (+HS) and models >1000 Vdc:60 Hz for remote analog voltage programming45 Hz for remote analog current programming
Control Specifications
Voltage Programming Accuracy ± 0.075% of full scale voltage
OVT Programming Accuracy ± 0.075% of full scale voltage
Current Programming Accuracy ± 0.075% of full scale current
OCT Programming Accuracy ± 0.075% of full scale current
Voltage Readback Accuracy ± 0.2% of full scale voltage
Current Readback Accuracy ± 0.2% of full scale current
External Analog Programming and Monitoring Levels
0 - 10 Vdc
External Analog Output Impedances Voltage output monitoring: 100 ΩCurrent output monitoring: 100 Ω+10 Vdc reference: 1 Ω
External Digital Programming and Monitoring Limits
Input: 0 to 5 Vdc, 10k input inpedance Output: 0 to 5 Vdc, 5 mA drive capacity
Remote Sense Limits 3% maximum voltage drop from output to load No remote sense on models above 1000 Vdc
Environmental Specifications
Ambient Operating Temperature 0 °C to 50 °C
Storage Temperature -25 °C to 85 °C
Humidity Relative humidity up to 95% non-condensing
Temperature Coefficient 0.04 % / °C of maximum output voltage0.06 % / °C of maximum output current
Air Flow Side air inlet, rear exhaust
Physical Specifications
Power Size (H” x W” x D”) Weight
2 kW 3.50 x 19 x 24 in (8.89 x 48.3 x 61.0 cm) 45 lbs (20.41 kg)
4 kW 3.50 x 19 x 24 in (8.89 x 48.3 x 61.0 cm) 47 lbs (21.32 kg)
6 kW 3.50 x 19 x 24 in (8.89 x 48.3 x 61.0 cm) 48 lbs (21.77 kg)
8 kW 3.50 x 19 x 24 in (8.89 x 48.3 x 61.0 cm) 48 lbs (21.77 kg)
10 kW 3.50 x 19 x 24 in (8.89 x 48.3 x 61.0 cm) 48 lbs (21.77 kg)
XR Series Specifications
Note: Specifications are subject to change without notice. For three-phase configurations, input specifications are line-to-line. Unless otherwise noted, input voltages and cur-rents are specified for three-phase configurations.
Output Current (Adc)
Out
put V
olta
ge (V
dc) (Voltage Maximum, Current Maximum)
Output Operation Region
Magna-Power Electronics • Programmable DC Power Supplies12
XR Series Models
2 kW 4 kW 6 kW 8 kW 10 kW
Voltage Maximum (Vdc)
Current Maximum (Adc)
Ripple (mVrms)
Efficiency (%)
5 375 600 N/A N/A N/A 50 8610 200 375 600 N/A N/A 50 8616 125 250 375 500 600 50 8620 100 200 300 375 500 45 8632 62 124 186 250 310 40 8640 50 100 150 200 250 40 8750 40 80 120 160 200 50 8780 25 50 75 100 125 60 87100 20 40 60 80 100 60 87125 16 32 48 64 80 100 87160 12 24 36 50 60 120 87200 10 20 30 40 50 125 87250 8 16 24 32 40 130 88375 5.3 10.6 15.9 21.3 26.5 170 88400 5.0 10.0 15.0 20.0 25 180 88500 4.0 8.0 12.0 16.0 20 220 88600 3.3 6.6 9.9 13.3 16.5 250 88800 2.5 5.0 7.5 10.0 12.5 300 881000 2.0 4.0 6.0 8.0 10 350 881250 1.6 3.2 4.8 6.4 8.0 375 881500 1.3 2.6 4.0 5.3 6.6 400 882000 1.0 2.0 3.0 4.0 5.0 450 884000 0.50 1.00 1.50 2.00 N/A 6500 886000 0.30 0.66 1.00 1.33 N/A 7500 888000 0.25 0.50 0.75 1.00 N/A 8500 8810000 0.20 0.40 0.60 0.80 N/A 9500 88
Input Current Per Phase (Aac)
208/240 Vac, 1Φ 16 N/A N/A N/A N/A208/240 Vac, 3Φ 8 15 22 29 36380/415 Vac, 3Φ 5 9 13 17 21440/480 Vac, 3Φ 4 8 11 15 18
XR 1000-8.0/208+HS+LXIProduct Series
Front Panel Type (Empty): Standard; C: Blank Note: Computer control and 37-pin isolated I/O included with all front panel types
Voltage Maximum
Current Maximum
Input Voltage 208 Vac 1Φ; 240 Vac 1Φ; 208 Vac 3Φ; 240 Vac 3Φ; 380 Vac 3Φ; 415 Vac 3Φ; 440 Vac 3Φ; 480 Vac 3Φ
Option Codes +HS, +GPIB, +LXI, +PPPE, +RS485, +UID, and +USB
Models ChartThe following chart details the available standard XR Series models. The Current Maximum (Adc) column is separated by the avail-able power levels. To determine the appropriate model, first select your output Voltage Maximum (Vdc) to find appropriate row. Next, select one desired Current Maximum from the row that contains your desired Voltage Maximum. Then, construct you model number according to the model ordering guide, above. Non-standard voltage and current configurations are available.
Model Ordering Guide
Note: Models above 2000 Vdc have high slew rate output. For models 2000 Vdc and below with the High Slew Rate Output Op-tion (+HS), ripple will be higher.
www.magna-power.com 13
1.250 24.000 1.875
0.875
1.966
DC VOLTAGE DC CURRENT
VOLTAGESTART STOP
CONFIGURATION
MENU
ITEM
V/I DIS
TRIP DIS
CLEAR
ENTER
CURRENTPWR
MODE
MAGNA-POWERELECTRONICS
MEP
IO
POWER
STANDBY
REM SEN
PGLLOC PHL THL OVT OCT
INT CTL
EXT CTL
ROTARY
EXT PGM
REMOTE
CTL CTL37516.0
PWR MAGNA-POWERELECTRONICS
MEP
IO
JS2 1 2
B3
INPUT
!
OUTPUT
NEG
A
C GNDPOS
JS1
JS3
0.234
3.469
0.32819.000
1.000
6.312
4.5000.500
NOT TO SCALE 24", 36", 60"
5
1
6
1
2
3
4
5
Front Panel Handles
Rear Air Exhaust
Output DC Connections (Front View)
Computer and External Control Connections
Remote Sensing Connector Models ≤1000 Vdc Only
Input AC Connections 10-32 Threaded Insert, Qty (4)
7 Side Air Intake
RST
LAN
REA
R PA
NEL
3/8-
16 T
HRE
AD
ED IN
SERT
, 4 P
LC'S
5.00
0
5.12
5
0.50
0
2.00
0
REA
R PA
NEL
.406
DIA
. TH
RU, 4
PLC
'S
5.00
0
5.12
5
0.25
0
0.25
0
.281
DIA
. TH
RURE
AR
PAN
EL
0.75
0
3.25
02.
250
2.25
0
JS1
JS3
JS1
JS3
JS5
JS4
RST
LAN
REA
R PA
NEL
3/8-
16 T
HRE
AD
ED IN
SERT
, 4 P
LC'S
5.00
0
5.12
5
0.50
0
2.00
0
REA
R PA
NEL
.406
DIA
. TH
RU, 4
PLC
'S
5.00
0
5.12
5
0.25
0
0.25
0
.281
DIA
. TH
RURE
AR
PAN
EL
0.75
0
3.25
02.
250
2.25
0
JS1
JS3
JS1
JS3
JS5
JS4
Optional (+LXI) Interface Optional (+GPIB) Interface
XR Series Diagrams
2 43
8
8 Output DC Connections (Side View) Connection Varies By Rated Output Voltage Refer to “DC Output Bus Connections”
Side View
Rear View
BA
D E F G
C
H
A MODE POWER: Indicates power output STANDBY: Indicates control power only
B FUNCTION KEYS MENU: Selects function ITEM: Selects item within function V/I DIS: Displays voltage/current settings TRIP DIS: Displays OVT and OCT settings CLEAR: Clears setting or resets fault ENTER: Selects item
C Meters display output voltage, output current, voltage set point, current set point, over voltage trip, and over current trip
D Power switch energizes control circuits without engaging main power
E Engages and disengages main power
F Stepless rotary knob to set voltage/current
G DIAGNOSTIC ALARMS LOC: Interlock PGL: External input voltage beyond limits PHL: Indicates under-voltage AC input THL: Indicates over-temperature condition OVT: Over-voltage protection has tripped OCT: Over-current protection has tripped
H CONFIGURATION REM SEN: Remote sense enabled INT CTL: Front panel start/stop/clear enabled EXT CTL: External start/stop/clear enabled ROTARY: Front panel control EXT PGM: External voltage/current control REMOTE: Computer control
XR Front Panel (Standard) C Version Front Panel
6
F D
9
High Voltage Output Cable (Included, Models Above 2000 Vdc)1110
9 Included Rear Protective Metal Cover
7
10 RG-8/U Coaxial Cable
11 PL-259 Connector
DC Output Bus Connections
OUTPUT
NEG POS
Standard Output Bus: Models ≤1000 Vdc
0.250 x 1.000 Tin Plated Copper Bus 3/8-16 Threaded Insert, Qty (2)
High Voltage Output Bus Models >1000 Vdc and ≤2000 Vdc
1/4-28 Bolt, 2 PLC’s
Very High Voltage Output Bus Models >2000 Vdc
83-1R Receptacle High Voltage Mating Cable Provided
Optional External Controls