Yaskawa Inverters
Wiring Comparison betweenGPD 315 and V1000
Old Lug Wiring
• Old GPD 315– L1, 2, and 3 Main Input– T1, 2, and 3 Main Output– B1 and 2 Braking Resistor– +1 and 2 DC Reactor
New Lug Wiring
• New V1000– L1, 2, and 3 Main Input– T1, 2, and 3 Main Output– B1 and 2 Braking Resistor– +1 and 2 DC Reactor
Lug Wiring Comparison
• Old GPD 315– L1, 2, and 3 Main Input– T1, 2, and 3 Main Output– B1 and 2 Braking Resistor– +1 and 2 DC Reactor
• New V1000– L1, 2, and 3 Main Input– T1, 2, and 3 Main Output– B1 and 2 Braking Resistor– +1 and 2 DC Reactor
Old TB Wiring
• Old GPD 315– S1 Forward Run– S2 Reverse Run– S3 External Fault– S4 Fault Reset– S5 Speed 1– S6 Speed 2– SC Common– FS Frequency Reference
Power Supply– FR Frequency Reference
Input– FC Frequency Reference
Common– MA Contact Output (NO)– MB Contact Output (NC)– MC Contact Common
New TB Wiring
• New V1000– S1 Forward Run– S2 Reverse Run– S3 External Fault– S4 Fault Reset– S5 Speed 1– S6 Speed 2– SC Common– +V Frequency Reference
Input Power Supply– A1 Frequency Reference
Input– AC Frequency Reference
Common– MA Contact Output (NO)– MB Contact Output (NC)– MC Contact Common
TB Wiring Comparison
• Old GPD 315– S1 Forward Run– S2 Reverse Run– S3 External Fault– S4 Fault Reset– S5 Speed 1– S6 Speed 2– SC Common– FS Frequency Reference
Power Supply– FR Frequency Reference
Input– FC Frequency Reference
Common– MA Contact Output (NO)– MB Contact Output (NC)– MC Contact Common
• New V1000– S1 Forward Run– S2 Reverse Run– S3 External Fault– S4 Fault Reset– S5 Speed 1– S6 Speed 2– SC Common– +V Frequency Reference
Input Power Supply– A1 Frequency Reference
Input– AC Frequency Reference
Common– MA Contact Output (NO)– MB Contact Output (NC)– MC Contact Common