+ All Categories
Home > Documents > You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits… Training Course SolidScan’s products.

Date post: 25-Dec-2015
Category:
Upload: hugh-owens
View: 212 times
Download: 0 times
Share this document with a friend
Popular Tags:
24
You can Measure the Benefits… Training Course SolidScan’s products
Transcript
Page 1: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

Training Course

SolidScan’s products

Page 2: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

SolidScanProducts range - MonoBlock

Solid level gauges are designed for non-contact, continuous measurement tasks. Solid’s devices are suitable for both liquid and solid applications.

MonoScan® MicroScan™

Page 3: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

SolidScanProducts range – Smart

Solid level gauges are designed for non-contact, continuous measurement tasks. Solid’s devices are suitable for both liquid and solid applications.

SmartScan® 50 SmartScan® 25 SmartLite®

Page 4: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

SolidScan

The SolidScan family of non contact ultrasonic level measurement instruments adapts to virtually all environments with no calibration, delivers the highest reliability for both liquids and solids, offers simple installation and operation.

Non contact ultrasonic level gauging

Page 5: You can Measure the Benefits… Training Course SolidScan’s products.

Training Course

Introduction to MonoScan

Page 6: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

MonoScan 2 wires

The MonoScan 2– wire unit, is a loop powered device of mono block construction.

Where can it be used ?

Liquid tanks with calm surfaces

Solids that are dust-free

Open channel flow

SolidScan

Page 7: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

MonoScan 2 wires

Type and Applications

MonoScan LFor liquid

MonoScan OFor open channel

MonoScan SFor solid

Short range0.25m - 5m

0.8ft - 16.40ft

0.25m - 5m

0.8ft - 16.40ft

0.25m - 5m

0.8ft - 16.40ft

Standard range

0.6m - 15m

1.6ft – 49ft

0.6m - 15m

1.6ft - 49ft

0.6m - 8.5m

1.6ft - 27.88ft

Page 8: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

MonoScan 2 wires

MonoScan has a range of up to 15 m (49 ft)

An accuracy of 0.25% within that range

Resolution of 1 mm (0.04")

Accuracy & Resolution

MonoScan 0.25%

5m 40m30m25m20m15m12m8.5m

SmartScan 50 0.1% - 0.25% SmartScan 25 0.25%

Page 9: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

Sensor

Aluminum with E-CTFE Coating Designed for complex environments

with problematic echo, such as non-conductive vapors or liquids

Good performance in problematic applications

High resistance in acid and alcoholic environments

Up to 15m/49ft measurement range

Sensors housing PP/PVDF

MonoScan 2 wires

Page 10: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

Connection diagram (Non Intrinsically safe)

* When using a power supply one must add a load resistor

MonoScan 2 wires

Page 11: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

PLC Power Supply recommendations

Power Supply Voltage

Minimum resistor value

Maximum resistor value

12V050

15V0220

24V41610

28V68820

MonoScan 2 wires

Page 12: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

Ripple/Noise recommended parameters for power supply switches: Less than 15V < 75 mV max p-p More than 15V < 100 mV max p-p

Power Supply recommendations

MonoScan 2 wires

Page 13: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

Connector diagram

2 wires connector (Pg7) 1 = + 24 V 2 = 0 V

MonoScan 2 wires

Conduit adapter (M20 or ½” NPT)

1 = 0 V 2 = +24 V

Page 14: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

Intrinsically Safe

MonoScan Intrinsically Safe is a 2– wire unit, of mono block construction.

The unit is aimed to be used in hazardous areas whereFlammable or explosive materials existing.

Operating at low energy can prevent electrical devices from creating arcs, sparks, or heat (during normal or fault conditions) that could ignite the explosive substance.

MonoScan IS performances are the same as MonoScan 2 wires

MonoScan 2 wires

Page 15: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

Intrinsically Safe Connection diagram (positive ground)

* When using a power supply one must add a load resistor

MonoScan 2 wires

Page 16: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

Intrinsically Safe Connection diagram (positive ground)

Zener Barrier Intrinsic Safety

Part Number Approval Barrier MonoScanTerminal Terminal

CENELAC, 3 27728- ATEX, FM, UL 4 1

CENELAC, 3 2 ATEX, FM, UL 4 1

Producer Interconnection

MTL

STAHL 9001\00-280-100-00

MonoScan 2 wires

Page 17: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

Intrinsically Safe - Power Supply

Power Supply Voltage

Minimum resistor value

Maximum resistor value

18V41 220

24V41 310

28V68 520

MonoScan 2 wires

Page 18: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

Ripple/Noise recommended parameters for power supply switches For more than 18V < 100 mV max p-p

MonoScan 2 wires Power Supply recommendations

Page 19: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

Software configurable Reduces stock requirement

Suitable for liquid, solid and open channel/flowA wide range of applications

Preprogrammed default settings simple to operate

Simple to install Ranges of up to 15m

(49ft)fits a variety of tanks

MonoScan Benefits

Page 20: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

Certificates

MonoScan compliant with the following industry standards:

CE – EMC FM (IS) –Class I, II, III, Division 1, Groups A, B, C, D, E, F and

G, T4. use in Div 1 with barrier.

ATEX – II 1G EEx ia IIC T4. for use in zone 0,1,2 with barrier

MonoScan

Page 21: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

Important Notes

The sensor should always be mounted above it’s dead zone.

If the device enter its blocking distance it will not measure correctly.

If possible, the sensor should be centered or at least 0.5m from sidewalls.

MonoScan

Page 22: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

The sensor should be placed as far as possible from filling or other noisy inlets.

The sensor should preferably be installed when the tank is empty, or at least 2/3 empty.

The sensor should be mount as perpendicular as possible

MonoScanImportant Notes

Page 23: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

Sensor Installation on a Triangular Tank

When installing the sensor on a tank with a triangular shaped top, it should not be placed in the center of the tank but 1/3 of the triangular height.

Use SBD function up to 1.5m value.

MonoScan

Page 24: You can Measure the Benefits… Training Course SolidScan’s products.

You can Measure the Benefits…

Sensor Installation Via Pipe

Pipe LengthPipe internal

Diameter

0.50 - 1m (1.64-3.28ft)

3-6 inch

Notes:

• When using a guided pipe the sensor should be mount at the center of the pipe and the pipe should be parallel to tank’s wall.

• It is strongly recommended to use Scan Distance when install through a pipe, to overcome interfering signals.

• For any pipe material’s beside plastic please consul factory prior installation.

MonoScan


Recommended