YOUR APP-BASEDDEVICEMANAGEMENTSOLUTION
FOLLOW-UPWORKFLOW
Reveal LINQ™ Mobile ManagerFor the Reveal LINQ™ Insertable Cardiac Monitor
iOS 1.04.02
2
THE REVEAL LINQ MOBILE MANAGERSUPPLEMENTAL RESOURCESLog on to Medtronic Academy to access resources supporting use of the application from setup to follow-up workflow:
MedtronicAcademy.com/RLMM
Reveal LINQ Mobile Manager | Follow-up Workflow | iOS 1.04.02 | January 2019
Detailed Educational Tools Prep, Setup, and Home Screen Module Insertion Workflow Module CareLink™ Network & Reports Module
Use Instructions Step-by-step user guide
to keep with your tablet. Access key reminders during app setup, device insertion, and follow-up device checks.
3
The Reveal LINQ™ Mobile Manager is an innovative, app-based device management system that makes it possible to manage all of your Reveal LINQ work flow needs — right from your tablet.
THE REVEAL LINQ MOBILE MANAGERAPP-BASED DEVICE MANAGEMENT
A Streamlined Solution to Simplify Monitoring
SIMPLEAn easy-to-use, app-based device management system.
SECUREDedicated protection of patient health data.
INTEGRATEDA single work flow solution from device activation to follow-up.
Reveal LINQ Mobile Manager | Follow-up Workflow | iOS 1.04.02 | January 2019
Patient Connector Communicates with the Reveal LINQ ICM and Mobile Manager for: Programming Follow-up Device Checks
Mobile Manager Communicates with the Medtronic CareLink Network Wi-Fi or cellular connection required
THE REVEAL LINQ MOBILE MANAGERMOBILE DEVICE MANAGEMENT SYSTEM
Patient Connector
Reveal LINQ™
ICMCareLink™
NetworkMobile ManagerApplication
4 Reveal LINQ Mobile Manager | Follow-up Workflow | iOS 1.04.02 | January 2019
5
THE REVEAL LINQ MOBILE MANAGERPREPARE
Battery Indicator Light (amber light)
Ensure the Patient Connector is chargedNOTE: The Patient Connector may run out of power during the insertion if the Battery Indicator amber light is on.
Ensure your tablet is charged
Ensure connection to Wi-Fi or a cellular network to obtain device registration and CareLink™ pre-enrollment.
ConnectionStatus
Battery Status
Reveal LINQ Mobile Manager | Follow-up Workflow | iOS 1.04.02 | January 2019
6
THE REVEAL LINQ MOBILE MANAGERAPP-BASED DEVICE MANAGEMENT
Reveal LINQ Mobile Manager | Follow-up Workflow | iOS 1.04.02 | January 2019
Connect to the Patient Connector
View Reports Review/Edit
Parameters
1 3Follow-up Workflow Overview
Connect to Reveal LINQ Device
2
7
THE REVEAL LINQ MOBILE MANAGERCONNECTIONS
Connect to the Patient Connector
Press and release the Power on button on the Patient Connector once to turn it on.
The blue indicator light will flash, changing to solid when connected to the app.
NOTE: If you are using a new patient connector that has not previously been paired with Reveal LINQ™ Mobile Manager, tap SELECT NEW PATIENT CONNECTOR and follow the prompts to pair the patient connector.
Bluetooth Indicator Light (blue light)
Power On button
Reveal LINQ Mobile Manager | Follow-up Workflow | iOS 1.04.02 | January 2019
8
THE REVEAL LINQ MOBILE MANAGERCONNECT TO REVEAL LINQ DEVICE
Place the patient connector over the Reveal LINQ™ ICM The Patient Connector light
will turn green when a connection is established
The Connect to the Reveal LINQ progress bar provides feedback that the patient connector is correctly positioned over the device and the device is being read
NOTE: Interrogation times vary between 30 seconds and 3 minutes, depending on the amount of data and episodes within the device, type of tablet being used, and other factors.
Reveal LINQ ICM Connection Indicator Light (green light)
Reveal LINQ Mobile Manager | Follow-up Workflow | iOS 1.04.02 | January 2019
9
THE REVEAL LINQ MOBILE MANAGERVIEW REPORTS
All patient and clinical data are fictitious and for demonstration purposes only.
Quick Look™ Screen
The Quick Look screen provides a summary of Reveal LINQ™ ICM status and diagnostic information collected since the last confirmed programming session using either the Reveal LINQ Mobile Manager or the 2090/Encore programmer.
NOTE: A confirmed programmer session is one that occurred at least 8 hours prior to the current interrogation/session.
Reveal LINQ Mobile Manager | Follow-up Workflow | iOS 1.04.02 | January 2019
10
THE REVEAL LINQ MOBILE MANAGERVIEW REPORTS
All patient and clinical data are fictitious and for demonstration purposes only.
Workflow Reports
To view a report, select the VIEW REPORT button. The Reports dialogue box will display
Reveal LINQ Mobile Manager | Follow-up Workflow | iOS 1.04.02 | January 2019
11
THE REVEAL LINQ MOBILE MANAGERVIEW REPORTS
All patient and clinical data are fictitious and for demonstration purposes only.
Reports Dialogue
After a follow-up device check session using the Reveal LINQ Mobile Manager, both the Quick Look™ and Full Reports are available.
NOTE: Access to the Full Report requires a wireless or cellular connection. If the Full Report option is not available, log onto the CareLink™ network to view the Full Report.
Reveal LINQ Mobile Manager | Follow-up Workflow | iOS 1.04.02 | January 2019
12
THE REVEAL LINQ MOBILE MANAGERVIEW REPORTS
All patient and clinical data are fictitious and for demonstration purposes only.
Quick Look™ Report
The Quick Look Report provides a basic overview of the Reveal LINQ™ ICM status and the patient’s condition.
Quick Look Report includes: Patient Information Current ECG Key Observations Counters Parameter Settings
Reveal LINQ Mobile Manager | Follow-up Workflow | iOS 1.04.02 | January 2019
13
THE REVEAL LINQ MOBILE MANAGERVIEW REPORTS
All patient and clinical data are fictitious and for demonstration purposes only.
Full Report
Full Report provides an extended overview of a patient’s condition and device functionality since the last confirmed programming session.
Full Report includes: Patient Information Current ECG Observations Counters Cardiac Compass™ trends Histograms Longest AF ECG Episode List Episode Details
NOTE: A confirmed programmer session is one that occurred at least 8 hours prior to the current interrogation/session from either Reveal LINQ™ Mobile Manager or 2090/Encore programmer.
Reveal LINQ Mobile Manager | Follow-up Workflow | iOS 1.04.02 | January 2019
THE REVEAL LINQ MOBILE MANAGERFULL REPORT VS. QUICK LOOK REPORT
14
FULL REPORT* QUICK LOOK™ REPORT
Available? Content Available? Content
Patient Information Yes Values interrogated at the start of the follow-up device check session. Yes Current values saved to Reveal LINQ™ ICM at
the time the View Report button is selected.
Current ECG Yes 10-second ECG interrogated at the start of the follow-up device check session. Yes
Screenshot ~5 seconds of streaming ECG taken by the Reveal LINQ Mobile Manager atthe time the View Report button is selected.
Counters Yes Since last clinic transmission†
and lifetime Yes Since last clinic transmission†
Observations Yes Since last clinic transmission† YesSince last clinic transmission†
Only a small set of observations (e.g., Daily Max Episode Count Met) are supported
Episode List, Episode Details Yes Since last clinic transmission†
(max of 30 episodes with ECG) No
Programmed Parameters No Values interrogated at the start of the follow-up device check session. Yes Current values saved to Reveal LINQ ICM at
the time the View Report button is selected.
Cardiac Compass™ Report Yes 90-day report No
* A full report is also available on the CareLink network. See Module 4 for details. † Last clinic transmission could be from the Reveal LINQ Mobile Manager or 2090/Encore programmer, whichever is most recent.
Reveal LINQ Mobile Manager | Follow-up Workflow | iOS 1.04.02 | January 2019
15
THE REVEAL LINQ MOBILE MANAGEREND FOLLOW-UP WORKFLOW
End Workflow To complete the follow-up device check workflow,
select the END SESSION button Complete this step to: Ensure that programming changes are transmitted
promptly to the patient’s CareLink™ record Avoid draining the Patient Connector’s battery
All patient and clinical data are fictitious and for demonstration purposes only.
Reveal LINQ Mobile Manager | Follow-up Workflow | iOS 1.04.02 | January 2019
16
THE REVEAL LINQ MOBILE MANAGERFOR ASSISTANCE
In-Application Contextual Help Look for the button.
Help Menu Look for the HELP option in the Application menu.
For questions or concerns with the tablet or connectivity: Contact your hospital’s IT help desk. Contact tablet manufacturer.
For additional assistance with the application or the Patient Connector: Visit LINQmobilemanager.com. Contact your Medtronic Representative.
Reveal LINQ Mobile Manager | Follow-up Workflow | iOS 1.04.02 | January 2019
THE REVEAL LINQ MOBILE MANAGERBRIEF STATEMENT
17
See the device manual for detailed information regarding the instructions for use, the implant procedure, indications,contraindications, warnings, precautions, and potential adverse events. If using an MRI SureScan device, see the MRISureScan® technical manual before performing an MRI. For further information contact your local Medtronic representativeand/or consult the Medtronic website at www.medtronic.com.
Consult instructions for use at this website. Manuals can be viewed using a current version of any major Internet browser. For best results, use Adobe Acrobat® Reader with the browser.
EuropeMedtronic International Trading Sàrl.Route du Molliau 31Case postaleCH-1131 Tolochenazwww.medtronic.euTel: +41 0 21 802 70 00Fax: +41 0 21 802 79 00
medtronic.eu
UC201802664a EE ©2019 Medtronic. All Rights Reserved. 01/2019
All rights reserved. Medtronic, Medtronic logo, and Further, Together are trademarks of Medtronic. The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Medtronic is under license. ™Other third party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.
United Kingdom/IrelandMedtronic LimitedBuilding 9Croxley Green Business ParkHatters LaneWatfordHerts WD18 8WW
www.medtronic.co.uk
Tel: +44 0 1923 212213Fax: +44 0 1923 241004
Reveal LINQ Mobile Manager | Follow-up Workflow | iOS 1.04.02 | January 2019