1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 A A B B C C D D 1 of 1 D Sheet Date: Revised: Date: Drawn: DOCUMENT DO NOT SCALE THIS Scale: Description: GENERAL ASSEMBLY 10HP TX-EXP-QX SCROLL SPC 200G RECEIVER MD 4/8/2020 JEB 11/18/2009 BEACONMEDÆS 4107 8511 79 Part Number: Rev: 03 DN: HOP200057 This drawing and the information contained thereon remain the property of BeaconMedaes and may not be used for other than the purpose for which it is loaned without the expressed written permission from BeaconMedaes Engineering. Notes: 1. INLET AND DISCHARGE CONNECTIONS HAVE INTEGRATED FLEX HOSE DESIGN. 2. SYSTEM WEIGHT: 3700 LBS (INCLUDES FUTURE EXPANSION TOWER) 3. INDICATES LIFTING POINTS 4. DENOTES CENTER OF GRAVITY (INCLUDES FUTURE EXPANSION TOWER) 5.93 C 18.49 C 34.82 D INTEGRATED LIFTING EYES 99.50 32.50 32.50 85.23 LIQUID LEVEL SIGHT GLASS W/FLOAT INDICATOR 5.46 I AIR RECEIVER 200 GALLON 72.00 13.72 D 70.50 37.75 I 2.13 28.25 4.25 32.50 34.50 4.25 Ø0.75 BOLTDOWN (12 PLACES) 0.75 24.00 24.00 24.00 36.00 MINIMUM CLEARANCE FOR MAINTENANCE AND VENTILATION SYSTEM CONNECTIONS ID DESCRIPTION C CONDENSATE DRAIN LOCATION I INLET LOCATION D DISCHARGE LOCATION DISCHARGE 1-1/4" FNPT FUTURE TOWER EXPANSION 26.60 35.42 46.20 ISOLATION VALVES FOR FUTURE EXPANSION MODULE INLET 3" NPT (FEMALE) HEAVY-DUTY 4-POINT ISOLATION (SEISMIC OPTIONAL) ELECTRICAL CONNECTION LIFELINE DUAL DESICCANT AIR DRYER W/441 VALVE DEW POINT TRANSDUCER CO TRANSDUCER INTAKE FILTER PER COMPRESSOR AFTER COOLER CONTROL CABINET SINGLE POINT CONDENSATE DRAIN CONNECTION 1/2" NPT (FEMALE) ZERO LOSS DRAIN VALVE
Transcript
Page 1: ZERO LOSS DRAIN VALVE · c condensate drain location i inlet location n o i t a c o l e g r a h c s i d d discharge 1-1/4" fnpt future tower 26.60 35.42 46.20 isolation valves for

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

A A

B B

C C

D D

1 of 1

DSheet

Date:Revised: Date: Drawn:

DOCUMENTDO NOT SCALE THIS

Scale:

Description:

GENERAL ASSEMBLY 10HPTX-EXP-QX SCROLL SPC 200G

RECEIVER

MD 4/8/2020 JEB 11/18/2009

BEACONMEDÆS

4107 8511 79Part Number:

Rev:03

DN:HOP200057

This drawing and the information contained thereon remain the property of BeaconMedaes and may not be used for other than the purpose for which it is loaned without the expressed written permission from BeaconMedaes Engineering.

Notes: 1. INLET AND DISCHARGE CONNECTIONS HAVE INTEGRATED FLEX HOSE DESIGN. 2. SYSTEM WEIGHT: 3700 LBS (INCLUDES FUTURE EXPANSION TOWER) 3. INDICATES LIFTING POINTS 4. DENOTES CENTER OF GRAVITY (INCLUDES FUTURE EXPANSION TOWER)

5.93C

18.49C

34.82D

INTEGRATEDLIFTING EYES

99.50

32.5032.50

85.23

LIQUID LEVELSIGHT GLASS

W/FLOATINDICATOR

5.46I

AIR RECEIVER200 GALLON

72.00

13.72D

70.50

37.75I

2.1328.254.25

32.5034.504.25

Ø0.75 BOLTDOWN(12 PLACES)

0.75

24.00

24.00

24.00

36.00

MINIMUM CLEARANCE FORMAINTENANCE AND VENTILATION

SYSTEM CONNECTIONSID DESCRIPTIONC CONDENSATE DRAIN LOCATIONI INLET LOCATIOND DISCHARGE LOCATION

DISCHARGE1-1/4" FNPT

FUTURE TOWER EXPANSION

26.60

35.42

46.20

ISOLATION VALVESFOR FUTUREEXPANSION MODULE

INLET3" NPT(FEMALE)

HEAVY-DUTY4-POINT ISOLATION(SEISMIC OPTIONAL)

ELECTRICALCONNECTION

LIFELINE DUALDESICCANT AIR

DRYER W/441 VALVE

DEW POINTTRANSDUCER

CO TRANSDUCER

INTAKE FILTERPER COMPRESSOR

AFTER COOLER

CONTROL CABINET

SINGLE POINT CONDENSATEDRAIN CONNECTION

1/2" NPT (FEMALE)

ZERO LOSSDRAIN VALVE