CTA: 142584 142584 Amsler HIT1100F drop weight tester Amsler HIT1100F drop weight tester, detail view The Amsler HIT1100F and Amsler HIT2000F were developed for testing components. They feature modular design and can optionally be equipped with acceleration unit and temperature chamber. These drop weight testers offer exceptional flexibility. Range of application • Component testing • Puncture tests on plastics to ISO 6603-2 and ASTM D3763 • Accelerated puncture tests on plastics in accordance with various automotive standards • Puncture tests on plastic films to ISO7765-2, ASTM D7192, ASTM D4272 • Charpy tests to ISO 179-2 • Izod tests to ISO 180 and ASTM D256 Advantages and features Reliable test results • Sturdy guides make these drop weight testers ideal for testing components. • High natural measuring frequency enables accurate test results. Flexibility • T-slotted mounting platforms allow flexible attachment of various test arrangements. • These drop weight testers can optionally be equipped with a temperature chamber and an acceleration unit. Zwick Materials testing Product Information Amsler HIT 1100F/HIT 2000F drop weight testers PI 940 0917
Transcript
Page 1: Zwick Materials testing · 2017. 10. 24. · D7192, ASTM D4272 • Charpy tests to ISO 179-2 • Izod tests to ISO 180 and ASTM D256 Advantages and features Reliable test results

CTA

: 142

584

1425

84

Amsler HIT1100F drop weight tester Amsler HIT1100F drop weight tester, detail view

The Amsler HIT1100F and Amsler HIT2000F weredeveloped for testing components. They featuremodular design and can optionally be

equipped with acceleration unit and temperaturechamber. These drop weight testers offer exceptionalflexibility.

Range of application• Component testing• Puncture tests on plastics to ISO 6603-2 and ASTM

D3763• Accelerated puncture tests on plastics in accordance

with various automotive standards• Puncture tests on plastic films to ISO7765-2, ASTM

D7192, ASTM D4272

• Charpy tests to ISO 179-2• Izod tests to ISO 180 and ASTM D256

Advantages and featuresReliable test results

• Sturdy guides make these drop weight testers idealfor testing components.

• High natural measuring frequency enables accuratetest results.

Flexibility• T-slotted mounting platforms allow flexible attachment

of various test arrangements.• These drop weight testers can optionally be equipped

with a temperature chamber and an acceleration unit.

ZwickMaterials testing

Product InformationAmsler HIT 1100F/HIT 2000F drop weight testers

PI 9

40 0

917

Page 2: Zwick Materials testing · 2017. 10. 24. · D7192, ASTM D4272 • Charpy tests to ISO 179-2 • Izod tests to ISO 180 and ASTM D256 Advantages and features Reliable test results

Technische Daten zum Grundgerät Amsler HIT1100F / HIT2000F

Item No. 1050792 1050814

Maximum energy 275 440 J

Dimensions

Height 3270 3870 mm

Width 1400 1400 mm

Depth 920 920 mm

Drop height, maximum 1 1,5 m

Drop height, minimum 0,05 0,05 m

Drop mass, maximum 29,4 29,4 kg

Drop mass, minimum 9,3 9,3 kg

Drop velocity, maximum 4,4 5,4 m/s at 1 m dropheight

Force signal resolution 16 16 bits

Measured-value rate (force signal), maxi‐mum

3 3 MHz

Clamping force 100 100 N

Weight 1450 1600 kg

Compressed air supply

Supply pressure 6 6 bar

Air consumption, approx. 10 20 l/impact

Required air-supply output-rate 600 600 l/min

Service unit mounted on instrument mounted on instrument

Required floor load capacity 20 20 kN/m²1)

Leveling feet concentrated load 150 166 N/cm²

Electrical supply data

Electrical supply 230 230 V (1 Ph, N, PE)

Power consumption (pre-load), approx. 16 16 A

1) It depends on the peak dynamic force the can be achieved

Accessories required

Tup-holder and weightsDescription Item number

Tup-holder with modular weight set up to 30 kg,comprising the following weight steps: 9,3 kg to 29,4 kg in 1kg steps

1050795

Mounts for clamping ringsDescription Item number

Mount for clamping rings for ISO and ASTM specimens(pneumatic clamping, temperature range -40 to 70°C)

1050857

Mount for clamping rings for ISO and ASTM specimens(manual clamping, temperature range -70 to 140°C)

1050858

ZwickMaterials testing

Product InformationAmsler HIT 1100F/HIT 2000F drop weight testers

We reserve the right to make technical changes in the course of ongoingdevelopment.

All data at ambient temperature.

Page 3: Zwick Materials testing · 2017. 10. 24. · D7192, ASTM D4272 • Charpy tests to ISO 179-2 • Izod tests to ISO 180 and ASTM D256 Advantages and features Reliable test results

Clamping rings

TypeInside diameter[mm] Clamping faces

Scope of delivery[pair] Item No.

Clamping rings as perISO 6603-2

20 grooved 1 1050797

Clamping rings as perISO 6603-2

40 grooved 1 1050796

Clamping rings as perASTM D3763

76 grooved 1 1050798

Clamping rings as perISO 7765-2

40 smooth 1 1050800

Force sensors

• Easily interchangeable• Replaceable tips• Guarded axial terminal for measuring lead

StandardDiameter[mm]

Max. force[kN] Item No.

ISO 6603-2 10 9 1050802

ISO 6603-2 20 15 1050801

ASTM D3763 12.7 (I/2") 15 1050803

Charpy and Izod testing equipmentA set of testing equipment consists of a basic mount, test fixture, load cell and striker.

Description Item number

Basic mount for Charpy and Izod test fixtures 1050806

Charpy test fixture1)

- for tests to ISO179-1/-2- incl. specimen centering

1050807

Izod test fixture1)

- for tests to ISO 180- incl. specimen centering

1050808

Tup incl. Piezo load cell, Fmax. 10kN, for Charpy and Izod 1050810

Striker as per ISO179-1/-2 (Charpy)2) 1050811

Striker as per ISO 180 (Izod) 2) 1050812

1) Required: basic mount for Charpy and Izod test fixtures2) Required: piezo load cell, Fmax. 10kN, for Charpy and Izod strikers

Optional accessories

Acceleration unit for Amsler HIT 1100FFor higher speeds and energies

ZwickMaterials testing

Product InformationAmsler HIT 1100F/HIT 2000F drop weight testers

We reserve the right to make technical changes in the course of ongoingdevelopment.

All data at ambient temperature.

Page 4: Zwick Materials testing · 2017. 10. 24. · D7192, ASTM D4272 • Charpy tests to ISO 179-2 • Izod tests to ISO 180 and ASTM D256 Advantages and features Reliable test results

• Easy to operate with Zwick Roell testing software

Description Item number

Acceleration unit for Amsler HIT1100F- Maximum impact velocity at 29,4 kg: 8,75 m/s- Maximum energy at 29,4 kg: 1126 J- Maximum impact velocity at 9,3 kg: 14,1m/s- Maximum energy at 9,3 kg: 926 J

1050793

Acceleration unit for Amsler HIT 2000FFor higher speeds and energies

• Easy to operate with Zwick Roell testing software

Description Item number

Acceleration unit for Amsler HIT2000F- Maximum impact velocity at 29,4 kg: 11,8 m/s- Maximum energy at 29,4 kg: 2044 J- Maximum impact velocity at 9,3 kg: 19,4 m/s- Maximum energy at 9,3 kg: 1745 J

1050815

Temperature chamberFor tests at low and high temperatures

Description Item number

Temperature chamber for Amsler HIT1100F and Amsler HIT2000F- Internal dimensions 400x400x400mm- Temperature range -70 to 180°C- LN² required for cooling

1050794

ZwickMaterials testing

Product InformationAmsler HIT 1100F/HIT 2000F drop weight testers

We reserve the right to make technical changes in the course of ongoingdevelopment.

All data at ambient temperature.