772
SANDY HSU MEAN WELL ENTERPRISES CO LTD 28 WUQUAN 3RD RD WUGU DIST NEW TAIPEI Date: 2014/02/21 248 TAIWAN Subscriber: 710861002 PartySite: 74570 File No: E183223 Project No: 4786203584 PD No: 14O06498 Type: R PO Number: Subject: Procedure And/Or Report Material The following material resulting from the investigation under the above numbers is enclosed. Issue Date Vol Sec Pages Revised Date X2 Index Page(s) 2010/05/19 X2 A92 Cert of Compliance 2010/05/19 X2 A92 Revised Proc/Rpt Section "If there are illegible images in this package, legible images may be found online via MyHome@UL under My UL Reports/CDA." Please file revised pages and illustrations in place of material of like identity. New material should be filed in its proper numerical order. NOTE: Follow-Up Service Procedure revisions DO NOT include Cover Pages, Test Records and Conclusion Pages. Report revisions DO NOT include Authorization Pages, Indices, Section General Pages and Appendixes. Please review this material and report any inaccuracies to UL's Customer Service Professionals. Contact information for all of UL's global offices can be found at http://www.ul.com/global/eng/pages/corporate/contactus. If you’d like to receive updated materials FASTER, UL offers electronic access and/or delivery of this material. For more details, contact UL's Customer Service Professionals as shown above. This material is provided on behalf of UL LLC(UL) or any authorized licensee of UL. TRT File
Transcript

SANDY HSU

MEAN WELL ENTERPRISES CO LTD

28 WUQUAN 3RD RD WUGU DIST

NEW TAIPEI Date: 2014/02/21

248 TAIWAN Subscriber: 710861002

PartySite: 74570

File No: E183223

Project No: 4786203584

PD No: 14O06498

Type: R

PO Number:

Subject: Procedure And/Or Report Material

The following material resulting from the investigation under the above numbers is enclosed.

Issue

Date Vol Sec Pages Revised Date

X2 Index Page(s)

2010/05/19 X2 A92 Cert of Compliance

2010/05/19 X2 A92 Revised Proc/Rpt Section

"If there are illegible images in this package, legible images may be found online via MyHome@UL

under My UL Reports/CDA."

Please file revised pages and illustrations in place of material of like identity. New material

should be filed in its proper numerical order.

NOTE: Follow-Up Service Procedure revisions DO NOT include Cover Pages, Test Records and Conclusion

Pages. Report revisions DO NOT include Authorization Pages, Indices, Section General Pages and

Appendixes.

Please review this material and report any inaccuracies to UL's Customer Service Professionals.

Contact information for all of UL's global offices can be found at

http://www.ul.com/global/eng/pages/corporate/contactus.

If you’d like to receive updated materials FASTER, UL offers electronic access and/or delivery of

this material. For more details, contact UL's Customer Service Professionals as shown above.

This material is provided on behalf of UL LLC(UL) or any authorized licensee of UL.

TRT File

File Volume Page Date:

E183223 Index X2 1 2014-02-20

Index

Product Type Model/Type Reference Report Reference # Status

Direct Plug In Switching Adapter and Cord Connected Switching Adapter

ES18xyy-zzz, where x can be B or U, yy can be 03, 05, 07, 09, 12, 15, 18, 24, 30 or 48, zzz can be 030-500 (indicate output voltage).

E183223-A29-UL

Cord Connected Switching Adapter

Model ES18xyy-zzz, where x can be A or C, yy can be 03, 05, 07, 09, 12, 15, 18, 24, 30 or 48, zzz denotes the output voltage, can be 030 - 500

E183223-A30-UL

Siwtching Power Adapter

ES25xyy-zzz, where x can be A or C, yy can be 05, 07, 09, 12, 15, 18, 24, 30, 36, or 48, zzz can be 0-9.

E183223-A43-UL

POWER DSINE HIGH POWER OVER ETHERNET MIDSPAN

POWERDSINE 8001, PD-8001/AC-xxxxxxxxxx (Power Dsine Ltd.), PD-8001-xxxxxxxxxx (Power Dsine Ltd.)

E183223-A44-UL

Switching Power Adapter

ES25xyy-zzz, where x can be B or U, yy can be 05, 07, 09, 12, 15, 18, 24, 30, 36, or 48, zzz can be 0-9.

E183223-A46-UL

Switching Power Adapter

AS-120P-X (X can be 12, 15, 20, 24 or 48) E183223-A68-UL

Power Supply GC30x-y, (x = B, U; y = 0, 1, 2, 4, 5, 6 or 11) E183223-A71-UL Switching Power Adaptor

GSwAy, w = 18 or 25, y = 03, 05, 07, 09, 12, 15, 18, 24, 28, or 48.

E183223-A75-UL

Switching Power Adaptor

GS25B17, GSwxy, where w=18 or 25, x=B or U and y can be 03, 05, 07, 09, 12, 15, 18, 24, 28 or 48. GS36xy, x =U and y =05,09, 12, 24, 48

E183223-A77-UL

AC/DC Switching Adapter

GS12Uy (y can be 05, 07, 09, 12, 15, 18 or 24 and denotes the output rating)

E183223-A89-UL

Switching Adapter GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS40A18, GS40A24, GS40A48 GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 GS60A56-NV1, GS60A48-CIS

E183223-A92-UL

Switching Adaptor GS90Ax, where x can be 12, 15, 19, 24, 48; GS90A56-NV1, GS90A24-R7BVS

E183223-A97-UL

Switching Mode Power Supply

GS220AX, (X = 12, 15, 20, 24, 48), GS220A48-AG1, GS280AX(X = 12, 15, 20, 24, 48), GC330AX (X=36, 48)

E183223-A113-UL

AC/DC SWITCHING ADAPTOR

GS160AX (X=12,15,20,24,48) E183223-A122-UL

AC/DC SWITCHING ADAPTOR

GS120AX (X=12, 15, 20, 24, 48) E183223-A124-UL

C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20140221-E183223 Report Reference E183223-A92-UL

Issue Date 2014-FEBRUARY-21

William R. Carney, Director, North American Certification Programs UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.com/contactus

Page 1 of 1

Issued to: MEAN WELL ENTERPRISES CO LTD 28 WUQUAN 3RD RD WUGU DIST NEW TAIPEI 248 TAIWAN

This is to certify that

representative samples of

Power Supplies for Information Technology Equipment Including Electrical Business Equipment Switching Adapter GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS40A18, GS40A24, GS40A48 GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 GS60A56-NV1, GS60A48-CIS

Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate.

Standard(s) for Safety: UL 60950-1 and CSA C22.2 No. 60950-1-07 - Information Technology Equipment - Safety - Part 1: General Requirements.

Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information

Only those products bearing the UL Listing Mark for the US and Canada should be considered as being covered by UL's Listing and Follow-Up Service meeting the appropriate requirements for US and Canada. The UL Listing Mark for the US and Canada generally includes: the UL in a circle symbol with “C” and

“US” identifiers: the word “LISTED”; a control number (may be alphanumeric) assigned by UL; and the product category name (product identifier) as indicated in the appropriate UL Directory. Look for the UL Listing Mark on the product.

Issue Date: 2010-05-19 Page 1 of 22 Report Reference # E183223-A92-UL

2014-02-21

Copyright © 2014

UL TEST REPORT AND PROCEDURE Standard: UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology

Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information Technology Equipment - Safety - Part 1: General Requirements)

Certification Type: Listing CCN: QQGQ, QQGQ7 (Power Supplies for Information Technology

Equipment Including Electrical Business Equipment)

Product: Switching Adapter Model: GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS40A18,

GS40A24, GS40A48 GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 GS60A56-NV1, GS60A48-CIS

Rating: Input: Models GS40Ay: 100-240 Vac, 50/60 Hz, 1.0 A Models GS60Ay, GS60A48-CIS: 100-240 Vac, 50/60 Hz, 1.4 A Model GS60A56-NV1: 100-240 Vac, 50/60 Hz, 1.4 A Output: Model GS40A05: 5 Vdc, 5.0 A max., 25 W max. Model GS40A07: 7.5 Vdc, 5.34 A max., 40 W max. Model GS40A09: 9 Vdc, 4.45 A max., 40 W max. Model GS40A12: 12 Vdc, 3.34 A max., 40 W max. Model GS40A15: 15 Vdc, 2.67 A max., 40 W max. Model GS40A18: 18 Vdc, 2.22 A max., 40 W max. Model GS40A24: 24 Vdc, 1.67 A max., 40 W max. Model GS40A48: 48 Vdc, 0.84 A max., 40 W max. Model GS60A05: 5 Vdc, 6.0 A max., 30 W max. Model GS60A07: 7.5 Vdc, 6.0 A max., 45 W max. Model GS60A09: 9 Vdc, 6.0 A max., 54 W max. Model GS60A12: 12 Vdc, 5.0 A max., 60 W max. Model GS60A15: 15 Vdc, 4.0 A max., 60 W max. Model GS60A18: 18 Vdc, 3.33 A max., 60 W max. Model GS60A24: 24 Vdc, 2.5 A max., 60 W max. Model GS60A48, GS60A48-CIS: 48 Vdc, 1.25 A max., 60 W max. Model GS60A56-NV1: 56 Vdc, 1.1 A max., 61.6 W max.

Applicant Name and Address: MEAN WELL ENTERPRISES CO LTD 28 WUQUAN 3RD RD WUGU DIST NEW TAIPEI 248 TAIWAN

Issue Date: 2010-05-19 Page 2 of 22 Report Reference # E183223-A92-UL

2014-02-21

Copyright © 2014

This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. Prepared by: Vincent Lai Reviewed by: C.T Wu

Issue Date: 2010-05-19 Page 3 of 22 Report Reference # E183223-A92-UL

2014-02-21

Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions - i. Part AC details important information which may be applicable to products covered by this Procedure.

Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report.

ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report.

iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.

Product Description

This product is a cord connected type power unit intended to be used for information technology equipment in TN power systems and are for indoor use only. It consists of an isolated transformer with electronic circuitry housed in a thermoplastic or metal enclosure sealed by screw and mechanical fixing. It is also provided with appliance inlet or non-detachable power cord for input connection and a length of cord terminated with a molded-on non-standard polarized output connector for output connection.

Model Differences

Models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS40A18, GS40A24, GS40A48 are identical to each other except for output rating and secondary winding of transformer. Models GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48, GS60A56-NV1 are identical to each other except for output rating and secondary winding of transformer. Models GS40Ay and GS60Ay, GS60A56-NV1 are identical except for transformer. Model GS60A48-CIS is similar to Model GS60A48 except following item - Change fuse (FS1) - Add Y-cap (C29) - Change enclosure material (to metal) and enclosure shape - Add potting epoxy fully in metal enclosure - Change to non-detachable power cord - Change circuit and layout

Technical Considerations

Equipment mobility : movable

Connection to the mains : pluggable A

Operating condition : continuous

Access location : operator accessible

Over voltage category (OVC) : OVC II

Mains supply tolerance (%) or absolute mains supply values : +10%, -10%

Tested for IT power systems : No

IT testing, phase-phase voltage (V) : N/A

Issue Date: 2010-05-19 Page 4 of 22 Report Reference # E183223-A92-UL

2014-02-21

Class of equipment : Class I (earthed)

Considered current rating of protective device as part of the building installation (A) : 20A

Pollution degree (PD) : PD 2

IP protection class : IP X0

Altitude of operation (m) : up to 2000 meters

Altitude of test laboratory (m) : less than 2000 meters

Mass of equipment (kg) : < 18

The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer’s specification of: 40 degree C

The means of connection to the mains supply is: Pluggable A, Detachable power cord

The product is intended for use on the following power systems: TN

The equipment disconnect device is considered to be: Appliance inlet

The following accessible locations (with circuit/schematic designation) are within a limited current circuit: C31,C32 secondary side (for all models except for model GS60A48-CIS);, C31 secondary side (for model secondary side)

The following circuit locations (with circuit/schematic designation) were investigated as a limited power source (LPS): Vout (+ to -)

The following are available from the Applicant upon request: Installation (Safety) Instructions / Manual

Loading test for Model GS60A48-CIS is not considered due to no mounting function. (by customer declared)

Additional Information

E183223-A92-UL, Revision: Alternate plastic material of enclosure, Sabic Plastic, Model 945(GG). E183223-A92-UL, Revision: 1. Adding new model GS60A56-NV1; 2. Upgrade standard to UL 60950-1, Ed.2 Project 4786203584, employing the alternate: 1. Add new Model GS60A48-CIS 2. Change fuse (FS1) for Model GS60A48-CIS 3. Add Y-cap (C29) for Model GS60A48-CIS 4. Change enclosure material (to metal) and enclosure shape for Model GS60A48-CIS 5. Add potting epoxy fully in metal enclosure for Model GS60A48-CIS 6. Change to non-detachable power cord for Model GS60A48-CIS 7. Change circuit and layout for Model GS60A48-CIS

Additional Standards

The product fulfills the requirements of: N/A

Markings and instructions

Clause Title Marking or Instruction Details

Power rating - Company identification

Listee's or Recognized company's name, Trade Name, Trademark or File Number

Issue Date: 2010-05-19 Page 5 of 22 Report Reference # E183223-A92-UL

2014-02-21

Power rating - Ratings

Ratings (voltage, frequency/dc, current)

Power rating - Model

Model Number

Fuses - Rating Rated current and voltage and type located on or adjacent to fuse or fuseholder.

Fuses - Non-operator access/soldered-in fuses

Unambiguous reference to service documentation for instructions for replacement of fuses replaceable only by service personnel

LPS Marking "Optionally marked with "LPS" or "Limited Power Source" on the unit."

Special Instructions to UL Representative

Inspect the transformer(s) listed in production line requirement per AA1.1- (C). When the tests are conducted at other location, inspect test record and specification sheet provided by the component manufacturer. Verify the specification sheet indicates 100% routine test specified in production line requirement be conducted at the component manufacturer.

Issue Date: 2010-05-19 Page 6 of 22 Report Reference # E183223-A92-UL

2014-02-21

Production-Line Testing Requirements

Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for further information.

Model Component Removable

Parts Test probe location V

rms V dc Test Time,

s

All T1 --- Primary - Secondary 3000

4242 1s

Earthing Continuity Test Exemptions - This test is not required for the following models:

N/A

Electric Strength Test Exemptions - This test is not required for the following models:

N/A

Electric Strength Test Component Exemptions - The following solid-state components may disconnected from the remainder of the circuitry during the performance of this test:

N/A

Sample and Test Specifics for Follow-Up Tests at UL

Model Component Material Test Sample(s) Test

Specifics

N/A --- --- --- --- ---

Issue Date: 2010-05-19 Page 7 of 22 Report Reference # E183223-A92-UL

2014-02-21

1.5.1 TABLE: list of critical components Pass Object/part or Description

Manufacturer/ trademark

type/model technical data Product Category CCN(s)

Required Marks of Conformity

Supplement ID

Enclosure Sabic Innovative Plastics Japan L L C

940(f1) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL 3-01

Enclosure (Alternate) Sabic Innovative Plastics US L L C

945(GG) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL 3-01

Enclosure (Alternate) Sabic Innovative Plastics Japan L L C

945(GG) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL 3-01

Enclosure (Alternate) Sabic Innovative Plastics B V

945(GG) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL 3-01

Enclosure (Alternate) (for Model GS60A48-CIS)

Various Various Metal (Aluminun). Minimum 0.8 mm thick. Four pieces constructions, Top Chassis, Bottom Chassis and side Chassis, secured together by screws. Overall approximate 144 mm by 61.5 mm by 32.25 mm.

-- --

Appliance Inlet Various Various Rated minimum 10 A, 250 Vac. Rated minimum 70 degree C. Grounded type, ground terminal directly soldered to

AXUT2, AXUT8 UL 3-01

Issue Date: 2010-05-19 Page 8 of 22 Report Reference # E183223-A92-UL

2014-02-21

earth trace on PWB. AC Power Supply Cord (for Model GS60A48-CIS only)

Various Various Type SVT or SPT-2, minimum 18 AWG, minimum 125 V, 10 A, with IEC-320-C14 Inlet or minimum 250 V, 10 A, with IEC-320-C14 Inlet.

ELBZ UL

Output Cord Various Various Maximum 3.05 m, marked VW-1 or FT-1, terminates with a polarized connector outside enclosure.

AVLV2, AVLV8 UL 3-02

Output Cord Strain Relief

Various Various PVC bushing integrally molded on output cord. Provided when Output Cord provided.

QMFZ2 UL 4-10

Insulating Tubing/Sleeving

Various Various FEP, PTFE, PVC, TFE, neoprene, or marked VW-1; 105 degree C, 300 V, min. 0.4 mm thick. See Table 2.10.3, Supplementary Info, for safety relevant locations.

UZFT2, UDPU2, YDTU2

UL 3-04

Printed Wiring Board Various Various Rated minimum V-1, minimum 130 degree C. See Table 2.10.3, Supplementary Info, for safety relevant locations.

ZPMV2 UL 5-03

Fuse (FS1) Various Various T2 A, 250 Vac. JDYX, JDYX7 UL 3-04 Fuse (FS1) (Alternate) Conquer Electronics

Co., Ltd. MST T2 A, 250 Vac. JDYX2, JDYX8 UL 3-04

Fuse (FS1) (for Model GS60A48-CIS only)

Conquer Electronics Co., Ltd.

MST T3.15A, 300Vac JDYX2, JDYX8 UL

Thermistor (RTH1) (Optional)

Various Various NTC, rated minimum 3 A, maximum 20 ohms, at 25 degree C.

-- -- 3-04

Line Choke (LF1) (Optional)

Various TR-732 Open type construction. Rated minimum 130 degree C.

-- -- 4-01

Core (LF1) Various Various Ferrite, toroidal, measured overall 9 mm OD by 5 mm ID by 3 mm wide.

-- -- 4-01

Issue Date: 2010-05-19 Page 9 of 22 Report Reference # E183223-A92-UL

2014-02-21

Coil (LF1) Various Various Rated minimum 130 degree C. OBMW2 UL 4-01 Triple Insulated Winding Wire (LF1)

Various Various Rated minimum 130 degree C. OBJT2 UL 4-01

X-Capacitor (C1) (Optional)

KEMET ELECTRONICS ITALIA SRL

R.46 Rated maximum 0.47 µF, minimum 250 Vac, 110 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL 3-04

X-Capacitor (C1) (Optional)(Alternate)

KEMET ELECTRONICS ITALIA SRL

R.49 Rated maximum 0.47 uF, minimum 250 Vac, 110 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

EPCOS ELECTRONIC COMPONENTS S A

B3292 series Rated maximum 0.47 uF, minimum 250 Vac, 105 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

ISKRA KONDENZATORJI D D

KNB1530 Rated maximum 0.47 uF minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

ISKRA KONDENZATORJI D D

KNB1560 Rated maximum 0.47 uF, minimum 250 Vac, 125 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

LIOW GU ELECTRONICS INDUSTRY CO LTD

GS-L Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp

FOWX2, FOWX8 UL

Issue Date: 2010-05-19 Page 10 of 22 Report Reference # E183223-A92-UL

2014-02-21

heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

X-Capacitor (C1) (Optional) (Alternate)

PILKOR ELECTRONICS CO LTD

PCX2 335M Rated maximum 0.47 uF, minimum 250 Vac, 105 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

PILKOR ELECTRONICS CO LTD

PCX2 337 Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

ULTRA TECH XIPHI ENTERPRISE CO LTD

HQX Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

VISHAY CAPACITORS BELGIUM N V

339 Rated maximum 0.47 uF, minimum 250 Vac, 110 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

CHENG TUNG INDUSTRIAL CO LTD

CTX Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

SHINY SPACE ENTERPRISE CO LTD

SX1 Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp

FOWX2, FOWX8 UL

Issue Date: 2010-05-19 Page 11 of 22 Report Reference # E183223-A92-UL

2014-02-21

heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

Bleeder Resistors (R1, R2) (Optional)

Various Various Each rated maximum 1.5 M ohms, minimum 1/4 W.

-- -- 3-04

Bleeder Resistors (R1, R2, R3) (for Model GS60A48-CIS only) (Optional)

Various Various Each rated maximum 1.5 M ohms, minimum 1/4 W.

-- --

Line Choke (LF2) (Optional)

Various TR-733 Open type construction. Rated minimum 130 degree C.

-- -- 4-02

Core (LF2) Various Various Ferrite, toroidal, measured overall 16 mm OD by 10 mm ID by 5 mm wide.

-- -- 4-02

Coil (LF2) Various Various Rated minimum 130 degree C. OBMW2 UL 4-02 Y-Capacitor (C30) (Optional)

MURATA MFG CO LTD

KX, KH Rated maximum 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL 3-04

Y-Capacitor (C30) (Optional) (Alternate)

WALSIN TECHNOLOGY CORP

AH, AC Rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Y-Capacitor (C30) (Optional) (Alternate)

TDK-EPC CORP. CD, CS Each rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Y-Capacitor (C30) (Optional) (Alternate)

WELSON INDUSTRIAL CO LTD

WD, KL Each rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp

FOWX2, FOWX8 UL

Issue Date: 2010-05-19 Page 12 of 22 Report Reference # E183223-A92-UL

2014-02-21

heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

Y-Capacitor (C29) (Optional) (for Model GS60A48-CIS only)

MURATA MFG CO LTD

KX, KH Rated maximum 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Y-Capacitor (C29) (Optional) (for Model GS60A48-CIS only) (Alternate)

WALSIN TECHNOLOGY CORP

AH, AC Rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Y-Capacitor (C29) (Optional) (for Model GS60A48-CIS only) (Alternate)

TDK-EPC CORP. CD, CS Each rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Y-Capacitor (C29) (Optional) (for Model GS60A48-CIS only) (Alternate)

WELSON INDUSTRIAL CO LTD

WD, KL Each rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Rectifier (BD1) Various Various Rated minimum 4 A, minimum 500 V.

-- -- 3-04

Electrolytic Capacitor (C5)

Various Various Integral pressure relief, rated maximum 120 µF, minimum 400 V, minimum 105 degree C.

-- -- 3-04

Transistor (Q1) Various Various Rated minimum 2 A, minimum 500 V.

-- -- 3-04

Bridge Capacitor (C31, C32) (Optional)

MURATA MFG CO LTD

KX Rated maximum 1000 pF, minimum 250 Vac, 125 degree

FOWX2, FOWX8 UL

Issue Date: 2010-05-19 Page 13 of 22 Report Reference # E183223-A92-UL

2014-02-21

C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

Bridge Capacitor (C31, C32) (Optional) (Alternate)

WALSIN TECHNOLOGY CORP

AH Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Capacitor (C31, C32) (Optional) (Alternate)

TDK-EPC CORP. CD Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Capacitor (C31, C32) (Optional) (Alternate)

WELSON INDUSTRIAL CO LTD

WD Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Capacitor (C31) (Optional) (for Model GS60A48-CIS only)

MURATA MFG CO LTD

KX Rated maximum 2200 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Capacitor (C31) (Optional) (for Model GS60A48-CIS only) (Alternate)

WALSIN TECHNOLOGY CORP

AH Rated maximum 2200 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Capacitor (C31) (Optional) (for Model

TDK-EPC CORP. CD Rated maximum 2200 pF, minimum 250 Vac, 125 degree

FOWX2, FOWX8 UL

Issue Date: 2010-05-19 Page 14 of 22 Report Reference # E183223-A92-UL

2014-02-21

GS60A48-CIS only) (Alternate)

C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

Bridge Capacitor (C31) (Optional) (for Model GS60A48-CIS only) (Optional) (Alternate)

WELSON INDUSTRIAL CO LTD

WD Rated maximum 2200 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Optical Isolator (U2, U3) Sharp Corp., Electronic Components Group

PC123 Minimum 3000 V ac isolation. Double protection.

FPQU2, FPQU8 UL 3-04

Optical Isolator (U2, U3) (Alternate)

Lite-On Technology Corp.

LTV-817, LTV-817M

Minimum 3000 V ac isolation. Double protection.

FPQU2, FPQU8 UL 3-04

Transformer (T1) (Models GS60Ay)

Long Sail Electronic Co., Ltd.

TF-1738, (for y=05), TF-1739 (for y=07), TF-1740 (for y=09), TF-1741 (for y=12), TF-1742 (for y=15), TF-1743 (for y=18), TF-1744 (for y=24), TF-1745 (for y=48), GS60A48-CIS

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL 4-03

Transformer (T1) (Models GS60Ay) (Alternate)

Jet Signal Industries Co., Ltd.

TF-1738, (for y=05), TF-1739 (for y=07), TF-1740 (for y=09), TF-1741 (for y=12), TF-1742 (for y=15), TF-1743 (for y=18), TF-1744 (for

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL 4-04

Issue Date: 2010-05-19 Page 15 of 22 Report Reference # E183223-A92-UL

2014-02-21

y=24), TF-1745 (for y=48), GS60A48-CIS

Transformer (T1) (Models GS40Ay)

Long Sail Electronic Co., Ltd.

TF-1782 (for y=05), TF-1783 (for y=07), TF-1784 (for y=09), TF-1785 (for y=12), TF-1786 (for y=15), TF-1787 (for y=18), TF-1788 (for y=24), TF-1789 (for y=48)

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL 4-05

Transformer (T1) (Models GS40Ay) (Alternate)

Jet Signal Industries Co., Ltd.

TF-1782 (for y=05), TF-1783 (for y=07), TF-1784 (for y=09), TF-1785 (for y=12), TF-1786 (for y=15), TF-1787 (for y=18), TF-1788 (for y=24), TF-1789 (for y=48)

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL 4-06

Core (T1) (Models GS60Ay)

Various Various Ferrite, measured overall 32 by 22.55 by 22 mm. Provided with Insulating tape, on bottom half of Core. Outer core wrapped with insulation tape.

-- -- 4-03

Core (T1) (Models GS40Ay)

Various Various Ferrite, measured overall 26.5 by 20.15 by 19 mm. Provided with Insulating tape, on bottom half of Core. Outer core wrapped with insulation tape.

-- -- 4-05

Coil (T1) Various Various Rated minimum 130 degree C. OBMW2 UL 4-03

Issue Date: 2010-05-19 Page 16 of 22 Report Reference # E183223-A92-UL

2014-02-21

Triple Insulated Winding Wire (T1)

Furukawa Electric Co., Ltd.

TEX-E Rated minimum 130 degree C. OBJT2 UL 4-03

Triple Insulated Winding Wire (T1) (Alternate)

Totoku Electric Co., Ltd.

TIW-2 Rated minimum 130 degree C. OBJT2 UL 4-03

Triple Insulated Winding Wire (T1) (Alternate)

Totoku Electric Co., Ltd.

TIW-3 Rated minimum 155 degree C. OBJT2 UL 4-03

Bobbin (T1) Sumitomo Bakelite Co., Ltd.

PM-9820, PM-9630

Rated V-0, 150 degree C, minimum 0.51 mm thick.

QMFZ2 UL 4-03

Insulating Tape (T1) 3M Company Electrical Markets DIV (EMD)

1350-1, 1350F-1, 1350T-1

Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL 4-03

Insulating Tape (T1) (Alternate)

Symbio Inc. 35660, 35660Y Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL 4-03

Insulating Tape (T1) (Alternate)

Bondtec Pacific Co., Ltd.

370S Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL 4-03

Varnish (T1) Hitachi Chemical Co., Ltd.

WP-2952F-2G Rated minimum 130 degree C. OBOR2 UL 4-03

Varnish (T1) (Alternate) John C Dolph Co. BC-346A Rated minimum 130 degree C. OBOR2 UL 4-03 Varnish (T1) (Alternate) Elantas Electrical

Insulation Elantas PDG Inc.

468-2-7++ Rated minimum 130 degree C. OBOR2 UL 4-03

Tubing (T1) Great Holding Industrial Co., Ltd.

TFT, TFL Rated minimum 200 degree C. Provided on all exit leads.

YDPU2 UL 4-03

Tubing (T1) (Alternate) Zeus Industrial Products Inc.

TFE-TW-300 Rated minimum 200 degree C. Provided on all exit leads.

YDPU2 UL 4-03

Issue Date: 2010-05-19 Page 17 of 22 Report Reference # E183223-A92-UL

2014-02-21

Transformer (T1) (Model GS60A56-NV1)

Jet Signal Industries Co., Ltd.

TF-5144 Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL

Transformer (T1) (Model GS60A56-NV1) (Alternate)

Mean Well Enterprises Co Ltd.

TF-5144 Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL

Core (T1) (Model GS60A56-NV1)

Various Various Ferrite, measured overall 26.5 by 20.15 by 19 mm. Provided with Insulating tape, on bottom half of Core. Outer core wrapped with insulation tape.

-- --

Coil (T1) (Model GS60A56-NV1)

Various Various Rated minimum 130 degree C. OBMW2 UL

Triple Insulated Winding Wire (T1) (Model GS60A56-NV1)

Furukawa Electric Co., Ltd.

TEX-E Rated minimum 130 degree C. OBJT2 UL

Bobbin (T1) (Model GS60A56-NV1)

Sumitomo Bakelite Co., Ltd.

PM-9820 Rated V-0, 150 degree C, minimum 0.51 mm thick.

QMFZ2 UL

Insulating Tape (T1) (Model GS60A56-NV1)

3M Company Electrical Markets DIV (EMD)

1350F-1 Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL 4-03

Insulating Tape (T1) (Model GS60A56-NV1) (Alternate)

Symbio Inc. 35660Y Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL 4-03

Varnish (T1) (Model GS60A56-NV1)

John C Dolph Co. BC-346A Rated minimum 130 degree C. OBOR2 UL

Tubing (T1) (Model GS60A56-NV1)

Great Holding Industrial Co., Ltd.

TFL Rated minimum 200 degree C. Provided on all exit leads.

YDPU2 UL

Heat Sink (HS1) Various Various Aluminum, minimum 1 mm thick. Provided with insulation

-- -- 4-07

Issue Date: 2010-05-19 Page 18 of 22 Report Reference # E183223-A92-UL

2014-02-21

tape near secondary parts. See Enclosure for detailed dimensions. Heat Sink (HS1) not provide on Model GS60A48-CIS

Heat Sink (HS2) Various Various Aluminum, minimum 1.5 mm thick. Provided with insulation tape near primary parts. See Enclosure for detailed dimensions. Heat Sink (HS2) not provide on Model GS60A48-CIS

-- -- 4-08

Insulation Tape (HS1, HS2)

Various Various Polyester tape, 0.05 mm thick, rated 130 degree C. See Enclosure for locations of tapes.

OANZ2 UL 4-09

LED (Optional) Various Various Located in SELV circuit. -- -- 3-04 Resistor (R42) (For Model GS40A05)

Various Various Rated minimum 0.91 ohms, minimum 2W.

-- -- 3-04

Resistor (R42) (For models GS40A07, GS40A12, GS40A15, GS40A24,GS40A48)

Various Various Rated minimum 0.62 ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For model GS40A09)

Various Various Rated minimum 0.6 ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For model GS40A18)

Various Various Rated minimum 0.68 ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For model GS60A05)

Various Various Rated minimum 0.91 ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For model GS60A07)

Various Various Rated minimum 0.6 ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For model GS60A09)

Various Various Rated minimum 0.47ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For models GS60A12, GS60A15, GS60A18,

Various Various Rated minimum 0.5 ohm , minimum 2W

-- -- 3-04

Issue Date: 2010-05-19 Page 19 of 22 Report Reference # E183223-A92-UL

2014-02-21

GS60A24) Resistor (R42) (For model GS60A48, GS60A48-CIS)

Various Various Rated minimum 0.56 ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For model GS60A56-NV1)

Various Various Rated minimum 0.5 ohm , minimum 2W

-- -- 3-04

Adhesive Glue Various Various Rated minimum V-2, 105 degree C.

QMFZ2 UL 3-04

Label Various Various Rated minimum 80 degree C. PGDQ2 UL 3-04 Insulation Sheet (Provided between PWB and bottom chassis) (Only for Model GS60A48-CIS)

-- -- See Enclosure ID 4-15 for dimension details. Materials are as followings.

-- --

-1. Material of Insulation Sheet

Formex,Div Of Illionis Tool Works Inc.

Formex GK Rated V-0, 115°C, minimum 0.2 mm thick.

QMFZ2 UL

-1a. Material of Insulation Sheet - Alternate

Sabic Innovative Plastics

FR700 Rated VTM-0, 80°C, minimum 0.2 mm thick.

QMFZ2 UL

-1b. Material of Insulation Sheet - Alternate

3M Taiwan Ltd IS-250-a Rated V-0, minimum 0.2 mm thick.

OCDT2 UL

-1c. Material of Insulation Sheet - Alternate

Sun Delta Corp VS(f) Rated VTM-0, 120°C, minimum 0.2 mm thick.

QMFZ2 UL

-1d. Material of Insulation Sheet - Alternate

Sichuan Dongfang Insulating Material Co Ltd

DFR117, DFR117ECOB

Rated V-0, 80°C, minimum 0.2 mm thick.

QMFZ2 UL

-1e. Material of Insulation Sheet - Alternate

Mianyang Longhua Film Co Ltd

PP-BK18 Rated V-0, 100°C, minimum 0.2 mm thick.

QMFZ2 UL

-1f. Material of Insulation Sheet - Alternate

Shenzhen Bornsun Industrial Co Ltd

BN-FP Rated V-0, 120°C, minimum 0.25 mm thick.

QMFZ2 UL

Epoxy Potting Compound (Only for Model GS60A48-CIS)

DOW Corning Corp SYLGARD 160 Rated V-0, 105 degree C. QMFZ2 UL

Epoxy Potting Shin-Etsu Silicone KET-132A/B Rated V-0, 105 degree C. QMFZ2 UL

Issue Date: 2010-05-19 Page 20 of 22 Report Reference # E183223-A92-UL

2014-02-21

Compound (Only for Model GS60A48-CIS) - Alternate Epoxy Potting Compound (Only for Model GS60A48-CIS) - Alternate

GUANGZHOU huitian

5299 Rated V-0, 150 degree C. QMFZ2 UL

Epoxy Potting Compound (Only for Model GS60A48-CIS) - Alternate

Shin-Etsu Silicone KET-132 A/B H Rated V-0, 105 degree C. QMFZ2 UL

Epoxy Potting Compound (Only for Model GS60A48-CIS) - Alternate

U-BOND UB5203 Rated V-0, 105 degree C. QMFZ2 UL

Bushing (For Model GS60A48-CIS)

Various Various V-2 min. For input power supply cord

QMFZ2 UL

Issue Date: 2010-05-19 Page 21 of 22 Report Reference # E183223-A92-UL

2014-02-21

Enclosures

Type Supplement Id Description

Photographs 3-01 Enclosure - Front View

Photographs 3-02 Enclosure - Rear View

Photographs 3-03 Internal - Top View

Photographs 3-04 PWB - Component View

Photographs 3-05 PWB - Trace View

Photographs 3-06 PWB - Component View for Model GS60A56-NV1

Photographs 3-07 External view - 1 (Model GS60A48-CIS)

Photographs 3-08 External view - 2 (Model GS60A48-CIS)

Photographs 3-09 Internal view (Model GS60A48-CIS)

Photographs 3-10 PWB top view (Model GS60A48-CIS)

Photographs 3-11 PWB bottom view (Model GS60A48-CIS)

Diagrams 4-01 Line Choke (LF1)

Diagrams 4-02 Line Choke (LF2)

Diagrams 4-03 Transformer (T1) (GS60Ay models) (Long Sail)

Diagrams 4-04 Transformer (T1) (GS60Ay models) (Jet Signal)

Diagrams 4-05 Transformer (T1) (GS40Ay models) (Long Sail)

Diagrams 4-06 Transformer (T1) (GS40Ay models) (Jet Signal)

Diagrams 4-07 Heat Sink (HS1)

Diagrams 4-08 Heat Sink (HS2)

Diagrams 4-09 Insulation Tape (HS1, HS2)

Diagrams 4-10 Strain Relief

Diagrams 4-11 Top Enclosure Drawing

Diagrams 4-12 Bottom Enclosure Drawing

Diagrams 4-13 Transformer (T1) (GS60A56-NV1 models) (Jet Signal)

Diagrams 4-14 Transformer (T1) (GS60A56-NV1 model) (Mean Well)

Diagrams 4-15 Mylar sheet drawing

Schematics + PWB 5-01 Circuit Schematic (GS60Ay models)

Schematics + PWB 5-02 Circuit Schematic (GS40Ay models)

Schematics + PWB 5-03 PWB Layout (All models)

Schematics + PWB 5-04 PWB Layout (model GS60A56-NV1)

Schematics + PWB 5-05 PWB layout (Model GS60A48-CIS)

Manuals

Miscellaneous

Issue Date: 2010-05-19 Page 22 of 22 Report Reference # E183223-A92-UL

2014-02-21

File E183223 Vol. X2 Sec. A92 PHO-01 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-02 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-03 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-04 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-05 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-06 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-07 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-08 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-09 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-10 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-11 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-01(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-01(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-01(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-02(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-02(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-02(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 12)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 13)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 14)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 15)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 16)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 17)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 18)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 19)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 20)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 12)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 12)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 13)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 14)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 15)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 16)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 17)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 18)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 19)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 20)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-07 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-08 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-09 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-10 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-11 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-12 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-13(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-13(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-13(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-13(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-13(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-13(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-13(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-14(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-14(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-14(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-14(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-14(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-14(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-14(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-15 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-01 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-02 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-04(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-04(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-04(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-04(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-04(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-04(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-05(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-05(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-05(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-05(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-05(Page 5)Issued: 2010-05-19

Issue Date: 2010-05-19 Page 1 of 8 Report Reference # E183223-A92-UL

Revision Date: 2014-02-21 Test Record

Test Record No. 1 This is to correct the resistance of R42 in Critical Components Table only.

Issue Date: 2010-05-19 Page 2 of 8 Report Reference # E183223-A92-UL

Revision Date: 2014-02-21 Test Record

Test Record No. 2 --The manufacturer submitted representative production sample of Switching Adaptor, Models:GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48,GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 employing the alternate plastic material of enclosure, Sabic Plastic, model 945. --All tests were conducted by PSE Inc. Taiwan located at San Chung City, Taipei, Taiwan under the TPTDP program. --Only the tests checked in “List of Tests” pages were deemed necessary. --Unless otherwise indicated, all tests were conducted on Models GS60A12. --Tests performed on Model GS60A12 were considered to be representative of models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48,GS60A05, GS60A07, GS60A09, GS60A15, GS60A18, GS60A24, GS60A48. --Only limited tests were performed on Models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48,GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 employing alternate plastic material of enclosure, Sabic Plastic, model 945 due to testing previously performed on the subject unit. --Test results reported related only to the items tested. The following tests were conducted: Test Testing Location/Comments Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this Test Report. The following supplements are provided as a part of this Test Record. NOTE: These supplements are only available to the Applicant via the CDA system.

Type Supplement Id Description

Attachment 2-04 CRD

Datasheet 2-05 Datasheet

Issue Date: 2010-05-19 Page 3 of 8 Report Reference # E183223-A92-UL

Revision Date: 2014-02-21 Test Record

Test Record No. 3 --The manufacturer submitted representative production sample of Switching Adaptor, Models: GS60A48 employing the alternate applied 2.10.3.9 - MEASUREMENT OF TRANSIENT LEVELS --Tests were conducted by (co. name & location) UL LLC / 260 Da-Yeh Road Peitou Taipei City, Taiwan 112. --Only the tests checked in "List of Tests" pages were deemed necessary. ---Unless otherwise indicated, all tests were conducted on Models GS60A48. ---Tests performed on Model GS60A48 were considered to be representative of models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS40A18, GS40A24, GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48. ---Only limited tests were performed on Models GS60A48 employing alternate applied 2.10.3.9 - MEASUREMENT OF TRANSIENT LEVELS due to testing previously performed on the subject unit. ---Test results reported related only to the items tested. The following tests were conducted: Test Testing Location/Comments Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this Test Report. The following supplements are provided as a part of this Test Record. NOTE: These supplements are only available to the Applicant via the CDA system.

Type Supplement Id Description

Datasheet 2-06 Datasheet

Attachment 2-07 CRD

Issue Date: 2010-05-19 Page 4 of 8 Report Reference # E183223-A92-UL

Revision Date: 2014-02-21 Test Record

Test Record No. 4 Correct typo in clause.

Issue Date: 2010-05-19 Page 5 of 8 Report Reference # E183223-A92-UL

Revision Date: 2014-02-21 Test Record

Test Record No. 5 -- The manufacturer submitted representative production samples of Switching Adapter, models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS40A18, GS40A24, GS40A48, GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48, GS60A56-NV1, employing the alternate (1) Adding new model GS60A56-NV1 which output rating 56 Vdc, 1.1 A; (2) Upgrade standard to UL 60950-1, Ed.2. -- Tests were conducted by PSE Inc., 9F-1, No.80, Sec 2 Guang Fu Rd., San Chung district, New Taipei City 241, Taiwan, under TPTDP. -- The unit was considered movable with exposed SELV circuit. -- Unless otherwise indicated, all tests were conducted on Model GS60A56-NV1. -- Only limited tests were performed on Model GS60A56-NV1 employing (1) Adding new model GS60A56-NV1 which output rating 56 Vdc, 1.1 A; (2) Upgrade standard to UL 60950-1, Ed.2, due to testing previously performed on the subject unit. -- Test RESULTS reported related only to the items tested.

Issue Date: 2010-05-19 Page 6 of 8 Report Reference # E183223-A92-UL

Revision Date: 2014-02-21 Test Record

The following tests were conducted: Test Testing Location/Comments End Product Reference Page

General Guidelines

Power Supply Reference Page

Guide Information Page - Maximum Output Voltage, Current, and Volt Ampere Measurement (1.2.2.1)

Input: Single-Phase (1.6.2)

Energy Hazard Measurements (2.1.1.5, 2.1.2, 1.2.8.10)

SELV Reliability Test Including Hazardous Voltage Measurements (2.2.2, 2.2.3, 2.2.4, Part 22 6.1)

Limited Power Source Measurements (2.5)

Humidity (2.9.1, 2.9.2, 5.2.2)

Determination of Working Voltage; Working Voltage Measurement (2.10.2)

Thin Sheet Material (2.10.5.9, 2.10.5.10, 2.10.5.6)

Transformer and Wire /Insulation Electric Strength (2.10.5.13)

Heating (4.5.1, 1.4.12, 1.4.13)

Electric Strength (5.2.2)

Abnormal Operation (5.3.1 - 5.3.9)

Transformer Abnormal Operation (5.3.3, 5.3.7b, Annex C.1)

Power Supply Output Short-Circuit/Overload (5.3.7)

Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this Test Report. The following supplements are provided as a part of this Test Record. NOTE: These supplements are only available to the Applicant via the CDA system.

Type Supplement Id Description

Datasheet 2-08 Datasheet

Attachment 2-09 CRD

Issue Date: 2010-05-19 Page 7 of 8 Report Reference # E183223-A92-UL

Revision Date: 2014-02-21 Test Record

Test Record No. 6 - The manufacturer submitted representing production samples of Switching Adapter, Model GS60A48-CIS. Employing the alternate: 1. Add new Model GS60A48-CIS 2. Change fuse (FS1) for Model GS60A48-CIS 3. Add Y-cap (C29) for Model GS60A48-CIS 4. Change enclosure material (to metal) and enclosure shape for Model GS60A48-CIS 5. Add potting epoxy fully in metal enclosure for Model GS60A48-CIS 6. Change to non-detachable power cord for Model GS60A48-CIS 7. Change circuit and layout for Model GS60A48-CIS - All Tests were conducted by Superior Product Consulting, Inc/3F, No. 10, Alley 6, Lane 235, Pao Chiao Road, Hsien Tien, Taipei, Taiwan under TPTDP program. - Test results reported relate only to the items tested. The following tests were conducted: Test Testing Location/Comments End Product Reference Page

General Guidelines

Power Supply Reference Page

Input: Single-Phase (1.6.2)

Limited Current Circuit Measurement (2.4.1, 2.4.2)

Protective Bonding II (2.6.3.4, 2.6.1)

Strain Relief (3.2.6, 4.2.1, 4.2.7) (for reference)

Steady Force (4.2.1 - 4.2.4)

Impact (4.2.5, 4.2.1, Part 22 10.2)

Drop (4.2.6, 4.2.1)

Stress Relief (4.2.7, 4.2.1) (for reference)

Heating (4.5.1, 1.4.12, 1.4.13)

Touch Current (Single-Phase; TN/TT System) (5.1, Annex D)

Electric Strength (5.2.2)

Component Failure (5.3.1, 5.3.4, 5.3.7)

Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this Test Report. The following tests were waived: Test Rationale for Waiving Loading - Wall and Ceiling Mounted Equipment (4.2.10) Loading test for Model GS60A48-CIS

is not considered due to no mounting function. (by customer declared)

Issue Date: 2010-05-19 Page 8 of 8 Report Reference # E183223-A92-UL

Revision Date: 2014-02-21 Test Record

The following supplements are provided as a part of this Test Record. NOTE: These supplements are only available to the Applicant via the CDA system.

Type Supplement Id Description

Attachment 2-10 CRD

Datasheet 2-12 Datasheet

MS. SANDY HSU

MEAN WELL ENTERPRISES CO LTD

28 WUQUAN 3RD RD WUGU DIST

NEW TAIPEI Date: 2013/02/28

248 TAIWAN Subscriber: 710861002

PartySite: 156523

File No: E183223

Project No: 13CA02856

PD No: 13O08742

Type: R

PO Number: 101-838, 101-091

Subject: Procedure And/Or Report Material

The following material resulting from the investigation under the above numbers is enclosed.

Issue

Date Vol Sec Pages Revised Date

2010/05/19 X2 A92 Cert of Compliance

X2 Index Page(s)

2010/05/19 X2 A92 Revised Proc/Rpt Section

If there are illegible images in this package, legible images may be found online via MyHome@UL

under My UL Reports/CDA.

Please file revised pages and illustrations in place of material of like identity. New material

should be filed in its proper numerical order.

NOTE: Follow-Up Service Procedure revisions DO NOT include Cover Pages, Test Records and Conclusion

Pages. Report revisions DO NOT include Authorization Pages, Indices, Section General Pages and

Appendixes.

Please review this material and report any inaccuracies to UL's Customer Service Professionals.

Contact information for all of UL's global offices can be found at

http://www.ul.com/global/eng/pages/corporate/contactus.

If you’d like to receive updated materials FASTER, UL offers electronic access and/or delivery of

this material. For more details, contact UL's Customer Service Professionals as shown above.

This material is provided on behalf of UL LLC(UL) or any authorized licensee of UL.

TRT File

File Volume Page Date:

E183223 Index X2 1 2013-02-27

Index

Product Type Model/Type Reference Report Reference # Status

Direct Plug In Switching Adapter and Cord Connected Switching Adapter

ES18xyy-zzz, where x can be B or U, yy can be 03, 05, 07, 09, 12, 15, 18, 24, 30 or 48, zzz can be 030-500 (indicate output voltage).

E183223-A29-UL

Cord Connected Switching Adapter

Model ES18xyy-zzz, where x can be A or C, yy can be 03, 05, 07, 09, 12, 15, 18, 24, 30 or 48, zzz denotes the output voltage, can be 030 - 500

E183223-A30-UL

Siwtching Power Adapter

ES25xyy-zzz, where x can be A or C, yy can be 05, 07, 09, 12, 15, 18, 24, 30, 36, or 48, zzz can be 0-9.

E183223-A43-UL

POWER DSINE HIGH POWER OVER ETHERNET MIDSPAN

POWERDSINE 8001, PD-8001/AC-xxxxxxxxxx (Power Dsine Ltd.), PD-8001-xxxxxxxxxx (Power Dsine Ltd.)

E183223-A44-UL

Switching Power Adapter

ES25xyy-zzz, where x can be B or U, yy can be 05, 07, 09, 12, 15, 18, 24, 30, 36, or 48, zzz can be 0-9.

E183223-A46-UL

Switching Power Adapter

AS-120P-X (X can be 12, 15, 20, 24 or 48) E183223-A68-UL

Power Supply GC30x-y, (x = B, U; y = 0, 1, 2, 4, 5, 6 or 11) E183223-A71-UL Switching Power Adaptor

GSwAy, w = 18 or 25, y = 03, 05, 07, 09, 12, 15, 18, 24, 28, or 48.

E183223-A75-UL

Switching Power Adaptor

GS25B17, GSwxy, where w=18 or 25, x=B or U and y can be 03, 05, 07, 09, 12, 15, 18, 24, 28 or 48. GS36xy, x =U and y =05,09, 12, 24, 48

E183223-A77-UL

AC/DC Switching Adapter

GS12Uy (y can be 05, 07, 09, 12, 15, 18 or 24 and denotes the output rating)

E183223-A89-UL

Switching Adapter GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS40A18, GS40A24, GS40A48 GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 GS60A56-NV1

E183223-A92-UL

Switching Adaptor GS90Ax, where x can be 12, 15, 19, 24, 48 E183223-A97-UL Switching Mode Power Supply

GS220AX, (X = 12, 15, 20, 24, 48), GS220A48-AG1 E183223-A113-UL

AC/DC SWITCHING ADAPTOR

GS160AX (X=12,15,20,24,48) E183223-A122-UL

AC/DC SWITCHING ADAPTOR

GS120AX (X=12, 15, 20, 24, 48) E183223-A124-UL

C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20130228-E183223 Report Reference E183223-A92-UL

Issue Date 2013-FEBRUARY-28

William R. Carney, Director, North American Certification Programs UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.com/contactus

Page 1 of 1

Issued to: MEAN WELL ENTERPRISES CO LTD 28 WUQUAN 3RD RD WUGU DIST NEW TAIPEI 248 TAIWAN

This is to certify that

representative samples of

Power Supplies for Information Technology Equipment Including Electrical Business Equipment Switching Adapter GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS40A18, GS40A24, GS40A48 GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48, GS60A56-NV1

Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate.

Standard(s) for Safety: UL 60950-1 and CSA C22.2 No. 60950-1-07 - Information Technology Equipment - Safety - Part 1: General Requirements.

Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information

Only those products bearing the UL Listing Mark for the US and Canada should be considered as being covered by UL's Listing and Follow-Up Service meeting the appropriate requirements for US and Canada. The UL Listing Mark for the US and Canada generally includes: the UL in a circle symbol with “C” and

“US” identifiers: the word “LISTED”; a control number (may be alphanumeric) assigned by UL; and the product category name (product identifier) as indicated in the appropriate UL Directory. Look for the UL Listing Mark on the product.

Issue Date: 2010-05-19 Page 1 of 17 Report Reference # E183223-A92-UL

2013-02-27

Copyright © 2013

UL TEST REPORT AND PROCEDURE Standard: UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology

Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information Technology Equipment - Safety - Part 1: General Requirements)

Certification Type: Listing CCN: QQGQ, QQGQ7 (Power Supplies for Information Technology

Equipment Including Electrical Business Equipment)

Product: Switching Adapter Model: GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS40A18,

GS40A24, GS40A48 GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 GS60A56-NV1

Rating: Input: Models GS40Ay: 100-240 Vac, 50/60 Hz, 1.0 A Models GS60Ay: 100-240 Vac, 50/60 Hz, 1.4 A Model GS60A56-NV1: 100-240 Vac, 50/60 Hz, 1.4 A Output: Model GS40A05: 5 Vdc, 5.0 A max., 25 W max. Model GS40A07: 7.5 Vdc, 5.34 A max., 40 W max. Model GS40A09: 9 Vdc, 4.45 A max., 40 W max. Model GS40A12: 12 Vdc, 3.34 A max., 40 W max. Model GS40A15: 15 Vdc, 2.67 A max., 40 W max. Model GS40A18: 18 Vdc, 2.22 A max., 40 W max. Model GS40A24: 24 Vdc, 1.67 A max., 40 W max. Model GS40A48: 48 Vdc, 0.84 A max., 40 W max. Model GS60A05: 5 Vdc, 6.0 A max., 30 W max. Model GS60A07: 7.5 Vdc, 6.0 A max., 45 W max. Model GS60A09: 9 Vdc, 6.0 A max., 54 W max. Model GS60A12: 12 Vdc, 5.0 A max., 60 W max. Model GS60A15: 15 Vdc, 4.0 A max., 60 W max. Model GS60A18: 18 Vdc, 3.33 A max., 60 W max. Model GS60A24: 24 Vdc, 2.5 A max., 60 W max. Model GS60A48: 48 Vdc, 1.25 A max., 60 W max. Model GS60A56-NV1: 56 Vdc, 1.1 A max., 61.6 W max.

Applicant Name and Address: MEAN WELL ENTERPRISES CO LTD 28 WUQUAN 3RD RD WUGU DIST NEW TAIPEI 248 TAIWAN

Issue Date: 2010-05-19 Page 2 of 17 Report Reference # E183223-A92-UL

2013-02-27

Copyright © 2013

This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. Prepared by: Hans Chen Reviewed by: David Tsou

Issue Date: 2010-05-19 Page 3 of 17 Report Reference # E183223-A92-UL

2013-02-27

Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions - i. Part AC details important information which may be applicable to products covered by this Procedure.

Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report.

ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report.

iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.

Product Description

This product is a cord connected type power unit intended to be used for information technology equipment in TN power systems and are for indoor use only. It consists of an isolated transformer with electronic circuitry housed in a thermoplastic enclosure sealed by screw and mechanical fixing. It is also provided with appliance inlet for input connection and a length of cord terminated with a molded-on non-standard polarized output connector for output connection.

Model Differences

Models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS40A18, GS40A24, GS40A48 are identical to each other except for output rating and secondary winding of transformer. Models GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48, GS60A56-NV1 are identical to each other except for output rating and secondary winding of transformer. Models GS40Ay and GS60Ay, GS60A56-NV1 are identical except for transformer.

Technical Considerations

Equipment mobility : movable

Connection to the mains : pluggable A

Operating condition : continuous

Access location : operator accessible

Over voltage category (OVC) : OVC II

Mains supply tolerance (%) or absolute mains supply values : +10%, -10%

Tested for IT power systems : No

IT testing, phase-phase voltage (V) : N/A

Class of equipment : Class I (earthed)

Considered current rating of protective device as part of the building installation (A) : 20A

Pollution degree (PD) : PD 2

IP protection class : IP X0

Altitude of operation (m) : up to 2000 meters

Issue Date: 2010-05-19 Page 4 of 17 Report Reference # E183223-A92-UL

2013-02-27

Altitude of test laboratory (m) : less than 2000 meters

Mass of equipment (kg) : < 18

The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer’s specification of: 40 degree C

The means of connection to the mains supply is: Pluggable A, Detachable power cord

The product is intended for use on the following power systems: TN

The equipment disconnect device is considered to be: Appliance inlet

The following accessible locations (with circuit/schematic designation) are within a limited current circuit: C31,C32 secondary side

The following circuit locations (with circuit/schematic designation) were investigated as a limited power source (LPS): Vout (+ to -)

The following are available from the Applicant upon request: Installation (Safety) Instructions / Manual

Additional Information

E183223-A92-UL, Revision: Alternate plastic material of enclosure, Sabic Plastic, Model 945(GG). E183223-A92-UL, Revision: 1. Adding new model GS60A56-NV1; 2. Upgrade standard to UL 60950-1, Ed.2

Additional Standards

The product fulfills the requirements of: N/A

Markings and instructions

Clause Title Marking or Instruction Details

Power rating - Company identification

Listee's or Recognized company's name, Trade Name, Trademark or File Number

Power rating - Ratings

Ratings (voltage, frequency/dc, current)

Power rating - Model

Model Number

Fuses - Rating Rated current and voltage and type located on or adjacent to fuse or fuseholder.

Fuses - Non-operator access/soldered-in fuses

Unambiguous reference to service documentation for instructions for replacement of fuses replaceable only by service personnel

Issue Date: 2010-05-19 Page 5 of 17 Report Reference # E183223-A92-UL

2013-02-27

LPS Marking "Optionally marked with "LPS" or "Limited Power Source" on the unit."

Special Instructions to UL Representative

Inspect the transformer(s) listed in production line requirement per AA1.1- (C). When the tests are conducted at other location, inspect test record and specification sheet provided by the component manufacturer. Verify the specification sheet indicates 100% routine test specified in production line requirement be conducted at the component manufacturer. Production-Line Testing Requirements

Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for further information.

Model Component Removable

Parts Test probe location V

rms V dc Test Time,

s

All T1 --- Primary - Secondary 3000

4242 1s

Earthing Continuity Test Exemptions - This test is not required for the following models:

N/A

Electric Strength Test Exemptions - This test is not required for the following models:

N/A

Electric Strength Test Component Exemptions - The following solid-state components may disconnected from the remainder of the circuitry during the performance of this test:

N/A

Sample and Test Specifics for Follow-Up Tests at UL

Model Component Material Test Sample(s) Test

Specifics

N/A --- --- --- --- ---

Issue Date: 2010-05-19 Page 6 of 17 Report Reference # E183223-A92-UL

2013-02-27

1.5.1 TABLE: list of critical components Pass Object/part or Description

Manufacturer/ trademark

type/model technical data Product Category CCN(s)

Required Marks of Conformity

Supplement ID

Enclosure Sabic Innovative Plastics Japan L L C

940(f1) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL 3-01

Enclosure (Alternate) Sabic Innovative Plastics US L L C

945(GG) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL 3-01

Enclosure (Alternate) Sabic Innovative Plastics Japan L L C

945(GG) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL 3-01

Enclosure (Alternate) Sabic Innovative Plastics B V

945(GG) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL 3-01

Appliance Inlet Various Various Rated minimum 10 A, 250 Vac. Rated minimum 70 degree C. Grounded type, ground terminal directly soldered to earth trace on PWB.

AXUT2, AXUT8 UL 3-01

Output Cord Various Various Maximum 3.05 m, marked VW-1 or FT-1, terminates with a polarized connector outside enclosure.

AVLV2, AVLV8 UL 3-02

Output Cord Strain Relief

Various Various PVC bushing integrally molded on output cord. Provided when Output Cord provided.

QMFZ2 UL 4-10

Issue Date: 2010-05-19 Page 7 of 17 Report Reference # E183223-A92-UL

2013-02-27

Insulating Tubing/Sleeving

Various Various FEP, PTFE, PVC, TFE, neoprene, or marked VW-1; 105 degree C, 300 V, min. 0.4 mm thick. See Table 2.10.3, Supplementary Info, for safety relevant locations.

UZFT2, UDPU2, YDTU2

UL 3-04

Printed Wiring Board Various Various Rated minimum V-1, minimum 130 degree C. See Table 2.10.3, Supplementary Info, for safety relevant locations.

ZPMV2 UL 5-03

Fuse (FS1) Various Various T2 A, 250 Vac. JDYX, JDYX7 UL 3-04 Fuse (FS1) (Alternate) Conquer Electronics

Co., Ltd. MST T2 A, 250 Vac. JDYX2, JDYX8 UL 3-04

Thermistor (RTH1) (Optional)

Various Various NTC, rated minimum 3 A, maximum 20 ohms, at 25 degree C.

-- -- 3-04

Line Choke (LF1) (Optional)

Various TR-732 Open type construction. Rated minimum 130 degree C.

-- -- 4-01

Core (LF1) Various Various Ferrite, toroidal, measured overall 9 mm OD by 5 mm ID by 3 mm wide.

-- -- 4-01

Coil (LF1) Various Various Rated minimum 130 degree C. OBMW2 UL 4-01 Triple Insulated Winding Wire (LF1)

Various Various Rated minimum 130 degree C. OBJT2 UL 4-01

X-Capacitor (C1) (Optional)

KEMET ELECTRONICS ITALIA SRL

R.46 Rated maximum 0.47 µF, minimum 250 Vac, 110 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL 3-04

X-Capacitor (C1) (Optional)(Alternate)

KEMET ELECTRONICS ITALIA SRL

R.49 Rated maximum 0.47 uF, minimum 250 Vac, 110 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Issue Date: 2010-05-19 Page 8 of 17 Report Reference # E183223-A92-UL

2013-02-27

X-Capacitor (C1) (Optional) (Alternate)

EPCOS ELECTRONIC COMPONENTS S A

B3292 series Rated maximum 0.47 uF, minimum 250 Vac, 105 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

ISKRA KONDENZATORJI D D

KNB1530 Rated maximum 0.47 uF minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

ISKRA KONDENZATORJI D D

KNB1560 Rated maximum 0.47 uF, minimum 250 Vac, 125 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

LIOW GU ELECTRONICS INDUSTRY CO LTD

GS-L Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

PILKOR ELECTRONICS CO LTD

PCX2 335M Rated maximum 0.47 uF, minimum 250 Vac, 105 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

PILKOR ELECTRONICS CO LTD

PCX2 337 Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Issue Date: 2010-05-19 Page 9 of 17 Report Reference # E183223-A92-UL

2013-02-27

X-Capacitor (C1) (Optional) (Alternate)

ULTRA TECH XIPHI ENTERPRISE CO LTD

HQX Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

VISHAY CAPACITORS BELGIUM N V

339 Rated maximum 0.47 uF, minimum 250 Vac, 110 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

CHENG TUNG INDUSTRIAL CO LTD

CTX Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

SHINY SPACE ENTERPRISE CO LTD

SX1 Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bleeder Resistors (R1, R2)

Various Various Each rated maximum 1.5 M ohms, minimum 1/4 W.

-- -- 3-04

Line Choke (LF2) (Optional)

Various TR-733 Open type construction. Rated minimum 130 degree C.

-- -- 4-02

Core (LF2) Various Various Ferrite, toroidal, measured overall 16 mm OD by 10 mm ID by 5 mm wide.

-- -- 4-02

Coil (LF2) Various Various Rated minimum 130 degree C. OBMW2 UL 4-02 Y-Capacitor (C30) (Optional)

MURATA MFG CO LTD

KX, KH Rated maximum 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days

FOWX2, FOWX8 UL 3-04

Issue Date: 2010-05-19 Page 10 of 17 Report Reference # E183223-A92-UL

2013-02-27

minimum. Certified to compliance with IEC 60384-14.

Y-Capacitor (C30) (Optional) (Alternate)

WALSIN TECHNOLOGY CORP

AH, AC Rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Y-Capacitor (C30) (Optional) (Alternate)

TDK-EPC CORP. CD, CS Each rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Y-Capacitor (C30) (Optional) (Alternate)

WELSON INDUSTRIAL CO LTD

WD, KL Each rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Rectifier (BD1) Various Various Rated minimum 4 A, minimum 500 V.

-- -- 3-04

Electrolytic Capacitor (C5)

Various Various Integral pressure relief, rated maximum 120 µF, minimum 400 V, minimum 105 degree C.

-- -- 3-04

Transistor (Q1) Various Various Rated minimum 2 A, minimum 500 V.

-- -- 3-04

Bridge Capacitor (C31, C32) (Optional)

MURATA MFG CO LTD

KX Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Capacitor (C31, C32) (Optional) (Alternate)

WALSIN TECHNOLOGY CORP

AH Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat

FOWX2, FOWX8 UL

Issue Date: 2010-05-19 Page 11 of 17 Report Reference # E183223-A92-UL

2013-02-27

test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

Bridge Capacitor (C31, C32) (Optional) (Alternate)

TDK-EPC CORP. CD Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Capacitor (C31, C32) (Optional) (Alternate)

WELSON INDUSTRIAL CO LTD

WD Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Optical Isolator (U2, U3) Sharp Corp., Electronic Components Group

PC123 Minimum 3000 V ac isolation. Double protection.

FPQU2, FPQU8 UL 3-04

Optical Isolator (U2, U3) (Alternate)

Lite-On Technology Corp.

LTV-817, LTV-817M

Minimum 3000 V ac isolation. Double protection.

FPQU2, FPQU8 UL 3-04

Transformer (T1) (Models GS60Ay)

Long Sail Electronic Co., Ltd.

TF-1738, (for y=05), TF-1739 (for y=07), TF-1740 (for y=09), TF-1741 (for y=12), TF-1742 (for y=15), TF-1743 (for y=18), TF-1744 (for y=24), TF-1745 (for y=48)

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL 4-03

Transformer (T1) (Models GS60Ay) (Alternate)

Jet Signal Industries Co., Ltd.

TF-1738, (for y=05), TF-1739 (for y=07), TF-1740 (for y=09), TF-1741 (for

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL 4-04

Issue Date: 2010-05-19 Page 12 of 17 Report Reference # E183223-A92-UL

2013-02-27

y=12), TF-1742 (for y=15), TF-1743 (for y=18), TF-1744 (for y=24), TF-1745 (for y=48)

Transformer (T1) (Models GS40Ay)

Long Sail Electronic Co., Ltd.

TF-1782 (for y=05), TF-1783 (for y=07), TF-1784 (for y=09), TF-1785 (for y=12), TF-1786 (for y=15), TF-1787 (for y=18), TF-1788 (for y=24), TF-1789 (for y=48)

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL 4-05

Transformer (T1) (Models GS40Ay) (Alternate)

Jet Signal Industries Co., Ltd.

TF-1782 (for y=05), TF-1783 (for y=07), TF-1784 (for y=09), TF-1785 (for y=12), TF-1786 (for y=15), TF-1787 (for y=18), TF-1788 (for y=24), TF-1789 (for y=48)

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL 4-06

Core (T1) (Models GS60Ay)

Various Various Ferrite, measured overall 32 by 22.55 by 22 mm. Provided with Insulating tape, on bottom half of Core. Outer core wrapped with insulation tape.

-- -- 4-03

Core (T1) (Models GS40Ay)

Various Various Ferrite, measured overall 26.5 by 20.15 by 19 mm. Provided with Insulating tape, on bottom

-- -- 4-05

Issue Date: 2010-05-19 Page 13 of 17 Report Reference # E183223-A92-UL

2013-02-27

half of Core. Outer core wrapped with insulation tape.

Coil (T1) Various Various Rated minimum 130 degree C. OBMW2 UL 4-03 Triple Insulated Winding Wire (T1)

Furukawa Electric Co., Ltd.

TEX-E Rated minimum 130 degree C. OBJT2 UL 4-03

Triple Insulated Winding Wire (T1) (Alternate)

Totoku Electric Co., Ltd.

TIW-2 Rated minimum 130 degree C. OBJT2 UL 4-03

Triple Insulated Winding Wire (T1) (Alternate)

Totoku Electric Co., Ltd.

TIW-3 Rated minimum 155 degree C. OBJT2 UL 4-03

Bobbin (T1) Sumitomo Bakelite Co., Ltd.

PM-9820, PM-9630

Rated V-0, 150 degree C, minimum 0.51 mm thick.

QMFZ2 UL 4-03

Insulating Tape (T1) 3M Company Electrical Markets DIV (EMD)

1350-1, 1350F-1, 1350T-1

Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL 4-03

Insulating Tape (T1) (Alternate)

Symbio Inc. 35660, 35660Y Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL 4-03

Insulating Tape (T1) (Alternate)

Bondtec Pacific Co., Ltd.

370S Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL 4-03

Varnish (T1) Hitachi Chemical Co., Ltd.

WP-2952F-2G Rated minimum 130 degree C. OBOR2 UL 4-03

Varnish (T1) (Alternate) John C Dolph Co. BC-346A Rated minimum 130 degree C. OBOR2 UL 4-03 Varnish (T1) (Alternate) Elantas Electrical

Insulation Elantas PDG Inc.

468-2-7++ Rated minimum 130 degree C. OBOR2 UL 4-03

Tubing (T1) Great Holding TFT, TFL Rated minimum 200 degree C. YDPU2 UL 4-03

Issue Date: 2010-05-19 Page 14 of 17 Report Reference # E183223-A92-UL

2013-02-27

Industrial Co., Ltd. Provided on all exit leads. Tubing (T1) (Alternate) Zeus Industrial

Products Inc. TFE-TW-300 Rated minimum 200 degree C.

Provided on all exit leads. YDPU2 UL 4-03

Transformer (T1) (Model GS60A56-NV1)

Jet Signal Industries Co., Ltd.

TF-5144 Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL

Transformer (T1) (Model GS60A56-NV1) (Alternate)

Mean Well Enterprises Co Ltd.

TF-5144 Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL

Core (T1) (Model GS60A56-NV1)

Various Various Ferrite, measured overall 26.5 by 20.15 by 19 mm. Provided with Insulating tape, on bottom half of Core. Outer core wrapped with insulation tape.

-- --

Coil (T1) (Model GS60A56-NV1)

Various Various Rated minimum 130 degree C. OBMW2 UL

Triple Insulated Winding Wire (T1) (Model GS60A56-NV1)

Furukawa Electric Co., Ltd.

TEX-E Rated minimum 130 degree C. OBJT2 UL

Bobbin (T1) (Model GS60A56-NV1)

Sumitomo Bakelite Co., Ltd.

PM-9820 Rated V-0, 150 degree C, minimum 0.51 mm thick.

QMFZ2 UL

Insulating Tape (T1) (Model GS60A56-NV1)

3M Company Electrical Markets DIV (EMD)

1350F-1 Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL 4-03

Insulating Tape (T1) (Model GS60A56-NV1) (Alternate)

Symbio Inc. 35660Y Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL 4-03

Varnish (T1) (Model GS60A56-NV1)

John C Dolph Co. BC-346A Rated minimum 130 degree C. OBOR2 UL

Tubing (T1) (Model Great Holding TFL Rated minimum 200 degree C. YDPU2 UL

Issue Date: 2010-05-19 Page 15 of 17 Report Reference # E183223-A92-UL

2013-02-27

GS60A56-NV1) Industrial Co., Ltd. Provided on all exit leads. Heat Sink (HS1) Various Various Aluminum, minimum 1 mm

thick. Provided with insulation tape near secondary parts. See Enclosure for detailed dimensions.

-- -- 4-07

Heat Sink (HS2) Various Various Aluminum, minimum 1.5 mm thick. Provided with insulation tape near primary parts. See Enclosure for detailed dimensions.

-- -- 4-08

Insulation Tape (HS1, HS2)

Various Various Polyester tape, 0.05 mm thick, rated 130 degree C. See Enclosure for locations of tapes.

OANZ2 UL 4-09

LED Various Various Located in SELV circuit. -- -- 3-04 Resistor (R42) (For Model GS40A05)

Various Various Rated minimum 0.91 ohms, minimum 2W.

-- -- 3-04

Resistor (R42) (For models GS40A07, GS40A12, GS40A15, GS40A24,GS40A48)

Various Various Rated minimum 0.62 ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For model GS40A09)

Various Various Rated minimum 0.6 ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For model GS40A18)

Various Various Rated minimum 0.68 ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For model GS60A05)

Various Various Rated minimum 0.91 ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For model GS60A07)

Various Various Rated minimum 0.6 ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For model GS60A09)

Various Various Rated minimum 0.47ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For models GS60A12, GS60A15, GS60A18, GS60A24)

Various Various Rated minimum 0.5 ohm , minimum 2W

-- -- 3-04

Issue Date: 2010-05-19 Page 16 of 17 Report Reference # E183223-A92-UL

2013-02-27

Resistor (R42) (For model GS60A48)

Various Various Rated minimum 0.56 ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For model GS60A56-NV1)

Various Various Rated minimum 0.5 ohm , minimum 2W

-- -- 3-04

Adhesive Glue Various Various Rated minimum V-2, 105 degree C.

QMFZ2 UL 3-04

Label Various Various Rated minimum 80 degree C. PGDQ2 UL 3-04

Issue Date: 2010-05-19 Page 17 of 17 Report Reference # E183223-A92-UL

2013-02-27

Enclosures

Type Supplement Id Description

Photographs 3-01 Enclosure - Front View

Photographs 3-02 Enclosure - Rear View

Photographs 3-03 Internal - Top View

Photographs 3-04 PWB - Component View

Photographs 3-05 PWB - Trace View

Photographs 3-06 PWB - Component View for Model GS60A56-NV1

Diagrams 4-01 Line Choke (LF1)

Diagrams 4-02 Line Choke (LF2)

Diagrams 4-03 Transformer (T1) (GS60Ay models) (Long Sail)

Diagrams 4-04 Transformer (T1) (GS60Ay models) (Jet Signal)

Diagrams 4-05 Transformer (T1) (GS40Ay models) (Long Sail)

Diagrams 4-06 Transformer (T1) (GS40Ay models) (Jet Signal)

Diagrams 4-07 Heat Sink (HS1)

Diagrams 4-08 Heat Sink (HS2)

Diagrams 4-09 Insulation Tape (HS1, HS2)

Diagrams 4-10 Strain Relief

Diagrams 4-11 Top Enclosure Drawing

Diagrams 4-12 Bottom Enclosure Drawing

Diagrams 4-13 Transformer (T1) (GS60A56-NV1 models) (Jet Signal)

Diagrams 4-14 Transformer (T1) (GS60A56-NV1 model) (Mean Well)

Schematics + PWB 5-01 Circuit Schematic (GS60Ay models)

Schematics + PWB 5-02 Circuit Schematic (GS40Ay models)

Schematics + PWB 5-03 PWB Layout (All models)

Schematics + PWB 5-04 PWB Layout (model GS60A56-NV1)

Manuals

Miscellaneous

File E183223 Vol. X2 Sec. A92 PHO-01 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-02 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-03 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-04 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-05 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-06 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-01(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-01(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-01(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-02(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-02(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-02(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 12)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 13)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 14)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 15)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 16)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 17)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 18)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 19)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 20)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 12)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 12)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 13)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 14)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 15)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 16)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 17)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 18)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 19)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 20)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-07 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-08 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-09 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-10 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-11 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-12 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-13(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-13(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-13(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-13(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-13(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-13(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-13(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-14(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-14(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-14(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-14(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-14(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-14(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-14(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-01 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-02 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-04(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-04(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-04(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-04(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-04(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-04(Page 6)Issued: 2010-05-19

Issue Date: 2010-05-19 Page 1 of 6 Report Reference # E183223-A92-UL

Revision Date: 2013-02-27 Test Record

Test Record No. 1 This is to correct the resistance of R42 in Critical Components Table only.

Issue Date: 2010-05-19 Page 2 of 6 Report Reference # E183223-A92-UL

Revision Date: 2013-02-27 Test Record

Test Record No. 2 --The manufacturer submitted representative production sample of Switching Adaptor, Models:GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48,GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 employing the alternate plastic material of enclosure, Sabic Plastic, model 945. --All tests were conducted by PSE Inc. Taiwan located at San Chung City, Taipei, Taiwan under the TPTDP program. --Only the tests checked in “List of Tests” pages were deemed necessary. --Unless otherwise indicated, all tests were conducted on Models GS60A12. --Tests performed on Model GS60A12 were considered to be representative of models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48,GS60A05, GS60A07, GS60A09, GS60A15, GS60A18, GS60A24, GS60A48. --Only limited tests were performed on Models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48,GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 employing alternate plastic material of enclosure, Sabic Plastic, model 945 due to testing previously performed on the subject unit. --Test results reported related only to the items tested. The following tests were conducted: Test Testing Location/Comments Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this Test Report. The following supplements are provided as a part of this Test Record. NOTE: These supplements are only available to the Applicant via the CDA system.

Type Supplement Id Description

Attachment 2-04 CRD

Datasheet 2-05 Datasheet

Issue Date: 2010-05-19 Page 3 of 6 Report Reference # E183223-A92-UL

Revision Date: 2013-02-27 Test Record

Test Record No. 3 --The manufacturer submitted representative production sample of Switching Adaptor, Models: GS60A48 employing the alternate applied 2.10.3.9 - MEASUREMENT OF TRANSIENT LEVELS --Tests were conducted by (co. name & location) UL LLC / 260 Da-Yeh Road Peitou Taipei City, Taiwan 112. --Only the tests checked in "List of Tests" pages were deemed necessary. ---Unless otherwise indicated, all tests were conducted on Models GS60A48. ---Tests performed on Model GS60A48 were considered to be representative of models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS40A18, GS40A24, GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48. ---Only limited tests were performed on Models GS60A48 employing alternate applied 2.10.3.9 - MEASUREMENT OF TRANSIENT LEVELS due to testing previously performed on the subject unit. ---Test results reported related only to the items tested. The following tests were conducted: Test Testing Location/Comments Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this Test Report. The following supplements are provided as a part of this Test Record. NOTE: These supplements are only available to the Applicant via the CDA system.

Type Supplement Id Description

Datasheet 2-06 Datasheet

Attachment 2-07 CRD

Issue Date: 2010-05-19 Page 4 of 6 Report Reference # E183223-A92-UL

Revision Date: 2013-02-27 Test Record

Test Record No. 4 Correct typo in clause.

Issue Date: 2010-05-19 Page 5 of 6 Report Reference # E183223-A92-UL

Revision Date: 2013-02-27 Test Record

Test Record No. 5 -- The manufacturer submitted representative production samples of Switching Adapter, models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS40A18, GS40A24, GS40A48, GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48, GS60A56-NV1, employing the alternate (1) Adding new model GS60A56-NV1 which output rating 56 Vdc, 1.1 A; (2) Upgrade standard to UL 60950-1, Ed.2. -- Tests were conducted by PSE Inc., 9F-1, No.80, Sec 2 Guang Fu Rd., San Chung district, New Taipei City 241, Taiwan, under TPTDP. -- The unit was considered movable with exposed SELV circuit. -- Unless otherwise indicated, all tests were conducted on Model GS60A56-NV1. -- Only limited tests were performed on Model GS60A56-NV1 employing (1) Adding new model GS60A56-NV1 which output rating 56 Vdc, 1.1 A; (2) Upgrade standard to UL 60950-1, Ed.2, due to testing previously performed on the subject unit. -- Test RESULTS reported related only to the items tested.

Issue Date: 2010-05-19 Page 6 of 6 Report Reference # E183223-A92-UL

Revision Date: 2013-02-27 Test Record

The following tests were conducted: Test Testing Location/Comments End Product Reference Page

General Guidelines

Power Supply Reference Page

Guide Information Page - Maximum Output Voltage, Current, and Volt Ampere Measurement (1.2.2.1)

Input: Single-Phase (1.6.2)

Energy Hazard Measurements (2.1.1.5, 2.1.2, 1.2.8.10)

SELV Reliability Test Including Hazardous Voltage Measurements (2.2.2, 2.2.3, 2.2.4, Part 22 6.1)

Limited Power Source Measurements (2.5)

Humidity (2.9.1, 2.9.2, 5.2.2)

Determination of Working Voltage; Working Voltage Measurement (2.10.2)

Thin Sheet Material (2.10.5.9, 2.10.5.10, 2.10.5.6)

Transformer and Wire /Insulation Electric Strength (2.10.5.13)

Heating (4.5.1, 1.4.12, 1.4.13)

Electric Strength (5.2.2)

Abnormal Operation (5.3.1 - 5.3.9)

Transformer Abnormal Operation (5.3.3, 5.3.7b, Annex C.1)

Power Supply Output Short-Circuit/Overload (5.3.7)

Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this Test Report. The following supplements are provided as a part of this Test Record. NOTE: These supplements are only available to the Applicant via the CDA system.

Type Supplement Id Description

Datasheet 2-08 Datasheet

Attachment 2-09 CRD

MS. SANDY HSU

MEAN WELL ENTERPRISES CO LTD

28 WUQUAN 3RD RD WUGU DIST

NEW TAIPEI Date: 2012/04/13

248 TAIWAN Subscriber: 710861002

PartySite: 156523

File No: E183223

Project No: 12CA16037

PD No: 12O14374

Type: R

PO Number: 101-0092

Subject: Procedure And/Or Report Material

The following material resulting from the investigation under the above numbers is enclosed.

Issue

Date Vol Sec Pages Revised Date

2010/05/19 X2 A92 Revised Proc/Rpt Section

“If there are illegible images in this package, legible images may be found online via MyHome@UL

under My UL Reports/CDA.”

Please file revised pages and illustrations in place of material of like identity. New material

should be filed in its proper numerical order.

NOTE: Follow-Up Service Procedure revisions DO NOT include Cover Pages, Test Records and Conclusion

Pages. Report revisions DO NOT include Authorization Pages, Indices, Section General Pages and

Appendixes.

Please review this material and report any inaccuracies to UL's Customer Service Professionals.

Contact information for all of UL's global offices can be found at

http://www.ul.com/global/eng/pages/corporate/contactus.

If you’d like to receive updated materials FASTER, UL offers electronic access and/or delivery of

this material. For more details, contact UL's Customer Service Professionals as shown above.

This material is provided on behalf of UL LLC(UL) or any authorized licensee of UL.

TRT File

Issue Date: 2010-05-19 Page 1 of 14 Report Reference # E183223-A92-UL

2012-04-13

Copyright © 2012

UL TEST REPORT AND PROCEDURE Standard: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology

Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03 (Information Technology Equipment - Safety - Part 1: General Requirements)

Certification Type: Listing CCN: QQGQ, QQGQ7 (Power Supplies for Information Technology

Equipment Including Electrical Business Equipment)

Product: Switching Adapter Model: GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS40A18,

GS40A24, GS40A48 GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48

Rating: Input: Models GS40Ay: 100-240 Vac, 50/60 Hz, 1.0 A Models GS60Ay: 100-240 Vac, 50/60 Hz, 1.4 A Output: Model GS40A05: 5 Vdc, 5.0 A max., 25 W max. Model GS40A07: 7.5 Vdc, 5.34 A max., 40 W max. Model GS40A09: 9 Vdc, 4.45 A max., 40 W max. Model GS40A12: 12 Vdc, 3.34 A max., 40 W max. Model GS40A15: 15 Vdc, 2.67 A max., 40 W max. Model GS40A18: 18 Vdc, 2.22 A max., 40 W max. Model GS40A24: 24 Vdc, 1.67 A max., 40 W max. Model GS40A48: 48 Vdc, 0.84 A max., 40 W max. Model GS60A05: 5 Vdc, 6.0 A max., 30 W max. Model GS60A07: 7.5 Vdc, 6.0 A max., 45 W max. Model GS60A09: 9 Vdc, 6.0 A max., 54 W max. Model GS60A12: 12 Vdc, 5.0 A max., 60 W max. Model GS60A15: 15 Vdc, 4.0 A max., 60 W max. Model GS60A18: 18 Vdc, 3.33 A max., 60 W max. Model GS60A24: 24 Vdc, 2.5 A max., 60 W max. Model GS60A48: 48 Vdc, 1.25 A max., 60 W max.

Applicant Name and Address: MEAN WELL ENTERPRISES CO LTD 28 WUQUAN 3RD RD WUGU DIST NEW TAIPEI 248 TAIWAN

This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety.

Issue Date: 2010-05-19 Page 2 of 14 Report Reference # E183223-A92-UL

2012-04-13

Copyright © 2012

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. Prepared by: David Tsou Reviewed by: Orville Chang

Issue Date: 2010-05-19 Page 3 of 14 Report Reference # E183223-A92-UL

2012-04-13

Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions - i. Part AC details important information which may be applicable to products covered by this Procedure.

Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report.

ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report.

iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.

Product Description

This product is a cord connected type power unit intended to be used for information technology equipment in TN power systems and are for indoor use only. It consists of an isolated transformer with electronic circuitry housed in a thermoplastic enclosure. It is also provided with appliance inlet for input connection and a length of cord terminated with a molded-on non-standard polarized output connector for output connection.

Model Differences

Models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS40A18, GS40A24, GS40A48 are identical to each other except for output rating and secondary winding of transformer. Models GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 are identical to each other except for output rating and secondary winding of transformer. Models GS40Ay and GS60Ay are identical except for transformer.

Technical Considerations

Equipment mobility : movable

Connection to the mains : pluggable A

Operating condition : continuous

Access location : operator accessible

Over voltage category (OVC) : OVC II

Mains supply tolerance (%) or absolute mains supply values : +10%, -10%

Tested for IT power systems : No

IT testing, phase-phase voltage (V) : N/A

Issue Date: 2010-05-19 Page 4 of 14 Report Reference # E183223-A92-UL

2012-04-13

Class of equipment : Class I (earthed)

Considered current rating (A) : 20A

Pollution degree (PD) : PD 2

IP protection class : IP X0

Altitude of operation (m) : 2000m

Altitude of test laboratory (m) : >2000m

Mass of equipment (kg) : < 18

The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer’s specification of: 40°C

The means of connection to the mains supply is: Pluggable A, Detachable power cord

The product is intended for use on the following power systems: TN

The equipment disconnect device is considered to be: Appliance inlet

The following accessible locations (with circuit/schematic designation) are within a limited current circuit: Vout (+ to -)

The following circuit locations (with circuit/schematic designation) were investigated as a limited power source (LPS): Vout (+ to -)

Additional Information

E183223-A92-UL, Revision: Alternate plastic material of enclosure, Sabic Plastic, Model 945.

Markings and instructions

Clause Title Marking or Instruction Details

Power rating - Ratings Ratings (voltage, frequency/dc, current)

Power rating - Model

Model Number

Power rating -

Listee's or Recognized company's name, Trade Name, Trademark or File

Issue Date: 2010-05-19 Page 5 of 14 Report Reference # E183223-A92-UL

2012-04-13

Company identification

Number

Fuses - Rating Rated current and voltage and type located on or adjacent to fuse or fuseholder.

Fuses - Non-operator access/soldered-in fuses

Unambiguous reference to service documentation for instructions for replacement of fuses replaceable only by service personnel

LPS Marking "Optionally marked with "LPS" or "Limited Power Source" on the unit."

Special Instructions to UL Representative

N/A Production-Line Testing Requirements

Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for further information.

Model Component Removable

Parts Test probe location V

rms V dc Test Time,

s

N/A --- --- --- --- --- ---

Earthing Continuity Test Exemptions - This test is not required for the following models:

N/A

Electric Strength Test Exemptions - This test is not required for the following models:

N/A

Electric Strength Test Component Exemptions - The following solid-state components may disconnected from the remainder of the circuitry during the performance of this test:

N/A

Sample and Test Specifics for Follow-Up Tests at UL

Model Component Material Test Sample(s) Test

Specifics

N/A --- --- --- --- ---

Issue Date: 2010-05-19 Page 6 of 14 Report Reference # E183223-A92-UL

2012-04-13

TABLE: List of Critical Components

Object/part or Description

Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

Enclosure Sabic Innovative Plastics Japan L L C

940(f1) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL

Enclosure (Alternate) Sabic Innovative Plastics US L L C

945(GG) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL

Enclosure (Alternate) Sabic Innovative Plastics Japan L L C

945(GG) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL

Enclosure (Alternate) Sabic Innovative Plastics B V

945(GG) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL

Appliance Inlet Various Various Rated minimum 10 A, 250 Vac. Rated minimum 70 degree C. Grounded type, ground terminal directly soldered to earth trace on PWB.

AXUT2, AXUT8 UL

Output Cord Various Various Maximum 3.05 m, marked VW-1 or FT-1, terminates with a polarized connector outside enclosure.

AVLV2, AVLV8 UL

Output Cord Strain Relief

Various Various PVC bushing integrally molded on output cord. Provided when Output Cord provided.

QMFZ2 UL

Insulating Tubing/Sleeving

Various Various FEP, PTFE, PVC, TFE, neoprene, or marked VW-1; 105 degree C, 300 V, min. 0.4 mm thick. See Table 2.10.3, Supplementary Info, for safety relevant locations.

UZFT2, UDPU2, YDTU2

UL

Printed Wiring Board Various Various Rated minimum V-1, minimum 130 degree C. See Table 2.10.3, Supplementary Info, for safety relevant locations.

ZPMV2 UL

Fuse (FS1) Various Various T2 A, 250 Vac. JDYX, JDYX7 UL Fuse (FS1) (Alternate) Conquer Electronics

Co., Ltd. MST T2 A, 250 Vac. JDYX2, JDYX8 UL

Thermistor (RTH1) (Optional)

Various Various NTC, rated minimum 3 A, maximum 20 ohms, at 25 degree C.

-- --

Line Choke (LF1) (Optional)

Various TR-732 Open type construction. Rated minimum 130 degree C.

-- --

Issue Date: 2010-05-19 Page 7 of 14 Report Reference # E183223-A92-UL

2012-04-13

Object/part or Description

Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

Core (LF1) Various Various Ferrite, toroidal, measured overall 9 mm OD by 5 mm ID by 3 mm wide.

-- --

Coil (LF1) Various Various Rated minimum 130 degree C. OBMW2 UL Triple Insulated Winding Wire (LF1)

Various Various Rated minimum 130 degree C. OBJT2 UL

X-Capacitor (C1) (Optional)

ARCOTRONICS SPA

R.46 Rated maximum 0.47 µF, minimum 250 Vac, 110 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional)(Alternate)

ARCOTRONICS SPA

R.49 Rated maximum 0.47 uF, minimum 250 Vac, 110 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

EPCOS ELECTRONIC COMPONENTS S A

B3292 series Rated maximum 0.47 uF, minimum 250 Vac, 105 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

ISKRA KONDENZATORJI D D

KNB1530 Rated maximum 0.47 uF minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

ISKRA KONDENZATORJI D D

KNB1560 Rated maximum 0.47 uF, minimum 250 Vac, 125 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

LIOW GU ELECTRONICS INDUSTRY CO LTD

GS-L Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

PILKOR ELECTRONICS CO LTD

PCX2 335M Rated maximum 0.47 uF, minimum 250 Vac, 105 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

PILKOR ELECTRONICS CO LTD

PCX2 337 Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to

FOWX2, FOWX8 UL

Issue Date: 2010-05-19 Page 8 of 14 Report Reference # E183223-A92-UL

2012-04-13

Object/part or Description

Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

compliance with IEC 60384-14. X-Capacitor (C1) (Optional) (Alternate)

ULTRA TECH XIPHI ENTERPRISE CO LTD

HQX Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

VISHAY CAPACITORS BELGIUM N V

339 Rated maximum 0.47 uF, minimum 250 Vac, 105 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

CHENG TUNG INDUSTRIAL CO LTD

CTX Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

SHINY SPACE ENTERPRISE CO LTD

SX1 Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bleeder Resistors (R1, R2)

Various Various Each rated 1.5 Mohms, minimum 1/4 W. -- --

Line Choke (LF2) (Optional)

Various TR-733 Open type construction. Rated minimum 130 degree C.

-- --

Core (LF2) Various Various Ferrite, toroidal, measured overall 16 mm OD by 10 mm ID by 5 mm wide.

-- --

Coil (LF2) Various Various Rated minimum 130 degree C. OBMW2 UL Y-Capacitor (C30) (Optional)

MURATA MFG CO LTD

KX, KH Rated maximum 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Y-Capacitor (C30) (Optional) (Alternate)

WALSIN TECHNOLOGY CORP

AH, AC Rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Y-Capacitor (C30) (Optional) (Alternate)

TDK-EPC CORP. CD, CS Each rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Issue Date: 2010-05-19 Page 9 of 14 Report Reference # E183223-A92-UL

2012-04-13

Object/part or Description

Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

Y-Capacitor (C30) (Optional) (Alternate)

WELSON INDUSTRIAL CO LTD

WD, KL Each rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Rectifier (BD1) Various Various Rated minimum 4 A, minimum 500 V. -- -- Electrolytic Capacitor (C5)

Various Various Integral pressure relief, rated maximum 120 µF, minimum 400 V, minimum 105 degree C.

-- --

Transistor (Q1) Various Various Rated minimum 2 A, minimum 500 V. -- -- Bridge Capacitor (C31, C32) (Optional)

MURATA MFG CO LTD

KX Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Capacitor (C31, C32) (Optional) (Alternate)

WALSIN TECHNOLOGY CORP

AH Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Capacitor (C31, C32) (Optional) (Alternate)

TDK-EPC CORP. CD Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Capacitor (C31, C32) (Optional) (Alternate)

WELSON INDUSTRIAL CO LTD

WD Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Optical Isolator (U2, U3) Sharp Corp., Electronic Components Group

PC123 Minimum 3000 V ac isolation. Double protection. FPQU2, FPQU8 UL

Optical Isolator (U2, U3) (Alternate)

Lite-On Technology Corp.

LTV-817 Minimum 3000 V ac isolation. Double protection. FPQU2, FPQU8 UL

Transformer (T1) (Models GS60Ay)

Long Sail Electronic Co., Ltd.

TF-1738, (for y=05), TF-1739 (for y=07), TF-1740 (for y=09), TF-1741 (for y=12), TF-1742 (for y=15), TF-

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL

Issue Date: 2010-05-19 Page 10 of 14 Report Reference # E183223-A92-UL

2012-04-13

Object/part or Description

Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

1743 (for y=18), TF-1744 (for y=24), TF-1745 (for y=48)

Transformer (T1) (Models GS60Ay) (Alternate)

Jet Signal Industries Co., Ltd.

TF-1738, (for y=05), TF-1739 (for y=07), TF-1740 (for y=09), TF-1741 (for y=12), TF-1742 (for y=15), TF-1743 (for y=18), TF-1744 (for y=24), TF-1745 (for y=48)

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL

Transformer (T1) (Models GS40Ay)

Long Sail Electronic Co., Ltd.

TF-1782 (for y=05), TF-1783 (for y=07), TF-1784 (for y=09), TF-1785 (for y=12), TF-1786 (for y=15), TF-1787 (for y=18), TF-1788 (for y=24), TF-1789 (for y=48)

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL

Transformer (T1) (Models GS40Ay) (Alternate)

Jet Signal Industries Co., Ltd.

TF-1782 (for y=05), TF-1783 (for y=07), TF-1784 (for y=09), TF-1785 (for y=12), TF-1786 (for y=15), TF-1787 (for y=18), TF-1788 (for y=24), TF-1789 (for y=48)

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL

Issue Date: 2010-05-19 Page 11 of 14 Report Reference # E183223-A92-UL

2012-04-13

Object/part or Description

Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

Core (T1) (Models GS60Ay)

Various Various Ferrite, measured overall 32 by 22.55 by 22 mm. Provided with Insulating tape, on bottom half of Core. Outer core wrapped with insulation tape.

-- --

Core (T1) (Models GS40Ay)

Various Various Ferrite, measured overall 26.5 by 20.15 by 19 mm. Provided with Insulating tape, on bottom half of Core. Outer core wrapped with insulation tape.

-- --

Coil (T1) Various Various Rated minimum 130 degree C. OBMW2 UL Triple Insulated Winding Wire (T1)

Furukawa Electric Co., Ltd.

TEX-E Rated minimum 130 degree C. OBJT2 UL

Triple Insulated Winding Wire (T1) (Alternate)

Totoku Electric Co., Ltd.

TIW-2 Rated minimum 130 degree C. OBJT2 UL

Triple Insulated Winding Wire (T1) (Alternate)

Totoku Electric Co., Ltd.

TIW-3 Rated minimum 155 degree C. OBJT2 UL

Bobbin (T1) Sumitomo Bakelite Co., Ltd.

PM-9820, PM-9630

Rated V-0, 150 degree C, minimum 0.51 mm thick. QMFZ2 UL

Insulating Tape (T1) 3M Co. 1350-1, 1350F-1, 1350T-1

Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL

Insulating Tape (T1) (Alternate)

Symbio Inc. 35660, 35660Y Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL

Insulating Tape (T1) (Alternate)

Bondtec Pacific Co., Ltd.

370S Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL

Varnish (T1) Hitachi Chemical Co., Ltd.

WP-2952F-2G Rated minimum 130 degree C. OBOR2 UL

Varnish (T1) (Alternate) John C Dolph Co. BC-346A Rated minimum 130 degree C. OBOR2 UL Varnish (T1) (Alternate) Elantas Electrical

Insulation Elantas PDG Inc.

468-2-7++ Rated minimum 130 degree C. OBOR2 UL

Tubing (T1) Great Holding Industrial Co., Ltd.

TFT, TFL Rated minimum 200 degree C. Provided on all exit leads.

YDPU2 UL

Tubing (T1) (Alternate) Zeus Industrial TFE-TW-300 Rated minimum 200 degree C. Provided on all exit YDPU2 UL

Issue Date: 2010-05-19 Page 12 of 14 Report Reference # E183223-A92-UL

2012-04-13

Object/part or Description

Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

Products Inc. leads. Heat Sink (HS1) Various Various Aluminum, minimum 1 mm thick. Provided with

insulation tape near secondary parts. See Enclosure for detailed dimensions.

-- --

Heat Sink (HS2) Various Various Aluminum, minimum 1.5 mm thick. Provided with insulation tape near primary parts. See Enclosure for detailed dimensions.

-- --

Insulation Tape (HS1, HS2)

Various Various Polyester tape, 0.05 mm thick, rated 130 degree C. See Enclosure for locations of tapes.

OANZ2 UL

LED Various Various Located in SELV circuit. -- -- Resistor (R42) (For Model GS40A05)

Various Various Rated minimum 0.91 ohms, minimum 2W. -- --

Resistor (R42) (For models GS40A07, GS40A12, GS40A15, GS40A24,GS40A48)

Various Various Rated minimum 0.62 ohm , minimum 2W -- --

Resistor (R42) (For model GS40A09)

Various Various Rated minimum 0.6 ohm , minimum 2W -- --

Resistor (R42) (For model GS40A18)

Various Various Rated minimum 0.68 ohm , minimum 2W -- --

Resistor (R42) (For model GS60A05)

Various Various Rated minimum 0.91 ohm , minimum 2W -- --

Resistor (R42) (For model GS60A07)

Various Various Rated minimum 0.6 ohm , minimum 2W -- --

Resistor (R42) (For model GS60A09)

Various Various Rated minimum 0.47ohm , minimum 2W -- --

Resistor (R42) (For models GS60A12, GS60A15, GS60A18, GS60A24)

Various Various Rated minimum 0.5 ohm , minimum 2W -- --

Resistor (R42) (For model GS60A48)

Various Various Rated minimum 0.56 ohm , minimum 2W -- --

Adhesive Glue Various Various Rated minimum V-2, 105 degree C. QMFZ2 UL Label Various Various Rated minimum 80 degree C. PGDQ2 UL

Issue Date: 2010-05-19 Page 13 of 14 Report Reference # E183223-A92-UL

2012-04-13

Issue Date: 2010-05-19 Page 14 of 14 Report Reference # E183223-A92-UL

2012-04-13

Enclosures

Type Supplement Id Description

Photographs 3-01 Enclosure - Front View

Photographs 3-02 Enclosure - Rear View

Photographs 3-03 Internal - Top View

Photographs 3-04 PWB - Component View

Photographs 3-05 PWB - Trace View

Diagrams 4-01 Line Choke (LF1)

Diagrams 4-02 Line Choke (LF2)

Diagrams 4-03 Transformer (T1) (GS60Ay models) (Long Sail)

Diagrams 4-04 Transformer (T1) (GS60Ay models) (Jet Signal)

Diagrams 4-05 Transformer (T1) (GS40Ay models) (Long Sail)

Diagrams 4-06 Transformer (T1) (GS40Ay models) (Jet Signal)

Diagrams 4-07 Heat Sink (HS1)

Diagrams 4-08 Heat Sink (HS2)

Diagrams 4-09 Insulation Tape (HS1, HS2)

Diagrams 4-10 Strain Relief

Diagrams 4-11 Top Enclosure Drawing

Diagrams 4-12 Bottom Enclosure Drawing

Schematics + PWB 5-01 Circuit Schematic (GS60Ay models)

Schematics + PWB 5-02 Circuit Schematic (GS40Ay models)

Schematics + PWB 5-03 PWB Layout (All models)

Manuals

Miscellaneous

File E183223 Vol. X2 Sec. A92 PHO-01 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-02 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-03 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-04 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-05 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-01(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-01(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-01(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-02(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-02(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-02(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 12)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 13)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 14)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 15)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 16)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 17)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 18)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 19)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 20)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 12)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 12)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 13)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 14)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 15)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 16)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 17)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 18)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 19)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 20)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-07 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-08 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-09 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-10 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-11 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-12 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-01 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-02 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 5)Issued: 2010-05-19

Issue Date: 2010-05-19 Page 1 of 4 Report Reference # E183223-A92-UL

Revision Date: 2012-04-13 Test Record

Test Record No. 1

This is to correct the resistance of R42 in Critical Components Table only.

Issue Date: 2010-05-19 Page 2 of 4 Report Reference # E183223-A92-UL

Revision Date: 2012-04-13 Test Record

Test Record No. 2

--The manufacturer submitted representative production sample of Switching Adaptor, Models:GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48,GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 employing the alternate plastic material of enclosure, Sabic Plastic, model 945. --All tests were conducted by PSE Inc. Taiwan located at San Chung City, Taipei, Taiwan under the TPTDP program. --Only the tests checked in “List of Tests” pages were deemed necessary. --Unless otherwise indicated, all tests were conducted on Models GS60A12. --Tests performed on Model GS60A12 were considered to be representative of models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48,GS60A05, GS60A07, GS60A09, GS60A15, GS60A18, GS60A24, GS60A48. --Only limited tests were performed on Models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48,GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 employing alternate plastic material of enclosure, Sabic Plastic, model 945 due to testing previously performed on the subject unit. --Test results reported related only to the items tested.

The following tests were conducted:

Test Testing Location/Comments End Product Reference Page

General Guidelines

Power Supply Reference Page

Strain Relief (3.2.6, 4.2.1, 4.2.7)

Steady Force (4.2.1 - 4.2.4)

Impact (4.2.5, 4.2.1, Part 22 10.2)

Drop (4.2.6, 4.2.1)

Stress Relief (4.2.7, 4.2.1) Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this Test Report.

Issue Date: 2010-05-19 Page 3 of 4 Report Reference # E183223-A92-UL

Revision Date: 2012-04-13 Test Record

The following supplements are provided as a part of this Test Record. NOTE: These supplements are only available to the Applicant via the CDA system.

Type Supplement Id Description

Attachment 2-04 CRD

Datasheet 2-05 Datasheet

Issue Date: 2010-05-19 Page 4 of 4 Report Reference # E183223-A92-UL

Revision Date: 2012-04-13 Test Record

Test Record No. 3

--The manufacturer submitted representative production sample of Switching Adaptor, Models: GS60A48 employing the alternate applied 2.10.3.9 - MEASUREMENT OF TRANSIENT LEVELS --Tests were conducted by (co. name & location) UL LLC / 260 Da-Yeh Road Peitou Taipei City, Taiwan 112. --Only the tests checked in "List of Tests" pages were deemed necessary. ---Unless otherwise indicated, all tests were conducted on Models GS60A48. ---Tests performed on Model GS60A48 were considered to be representative of models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS40A18, GS40A24, GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48. ---Only limited tests were performed on Models GS60A48 employing alternate applied 2.10.3.9 - MEASUREMENT OF TRANSIENT LEVELS due to testing previously performed on the subject unit. ---Test results reported related only to the items tested.

The following tests were conducted:

Test Testing Location/Comments End Product Reference Page

General Guidelines

Power Supply Reference Page

Measurement of Transient Levels (2.10.3.9) Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this Test Report.

The following supplements are provided as a part of this Test Record. NOTE: These supplements are only available to the Applicant via the CDA system.

Type Supplement Id Description

Datasheet 2-06 Datasheet

Attachment 2-07 CRD

MS. SANDY HSU

MEAN WELL ENTERPRISES CO LTD

28 WUQUAN 3RD RD WUGU DIST

NEW TAIPEI Date: 2011/09/29

248 TAIWAN Subscriber: 710861002

PartySite: 156523

File No: E183223

Project No: 11SR8076908

PD No: 11O39811

Type: R

PO Number:

Subject: Procedure And/Or Report Material

The following material resulting from the investigation under the above numbers is enclosed.

Issue

Date Vol Sec Pages Revised Date

X2 Index Page(s)

2010/05/19 X2 A92 Revised Proc/Rpt Section

"If there are illegible images in this package, legible images may be found online via MyHome@UL

under My UL Reports/CDA."

“Revisions Resulting from a Variation Notice VN E183223 X21109211047 issued (2011-09-21)”

Please file revised pages and illustrations in place of material of like identity. New material

should be filed in its proper numerical order.

NOTE: Follow-Up Service Procedure revisions DO NOT include Cover Pages, Test Records and Conclusion

Pages. Report revisions DO NOT include Authorization Pages, Indices, Section General Pages and

Appendixes.

Please review this material and report any inaccuracies to UL's Customer Service Professionals.

Contact information for all of UL's global offices can be found at

http://www.ul.com/global/eng/pages/corporate/contactus.

If you’d like to receive updated materials FASTER, UL offers electronic access and/or delivery of

this material. For more details, contact UL's Customer Service Professionals as shown above.

This material is provided on behalf of Underwriters Laboratories Inc.(UL) or any authorized licensee

of UL.

TRT File

File Volume Page Date:

E183223 Index X2 1 2011-09-28

Index

Product Type Model/Type Reference Report Reference # Status

Direct Plug In Switching Adapter and Cord Connected Switching Adapter

ES18xyy-zzz, where x can be B or U, yy can be 03, 05, 07, 09, 12, 15, 18, 24, 30 or 48, zzz can be 030-500 (indicate output voltage).

E183223-A29-UL

Cord Connected Switching Adapter

Model ES18xyy-zzz, where x can be A or C, yy can be 03, 05, 07, 09, 12, 15, 18, 24, 30 or 48, zzz denotes the output voltage, can be 030 - 500

E183223-A30-UL

Siwtching Power Adapter

ES25xyy-zzz, where x can be A or C, yy can be 05, 07, 09, 12, 15, 18, 24, 30, 36, or 48, zzz can be 0-9.

E183223-A43-UL

POWER DSINE HIGH POWER OVER ETHERNET MIDSPAN

POWERDSINE 8001, PD-8001/AC-xxxxxxxxxx (Power Dsine Ltd.), PD-8001-xxxxxxxxxx (Power Dsine Ltd.)

E183223-A44-UL

Switching Power Adapter

ES25xyy-zzz, where x can be B or U, yy can be 05, 07, 09, 12, 15, 18, 24, 30, 36, or 48, zzz can be 0-9.

E183223-A46-UL

Switching Power Adapter

AS-120P-X (X can be 12, 15, 20, 24 or 48) E183223-A68-UL

Power Supply GC30x-y, (x = B, U; y = 0, 1, 2, 4, 5, 6 or 11) E183223-A71-UL Switching Power Adaptor

GSwAy, w = 18 or 25, y = 03, 05, 07, 09, 12, 15, 18, 24, 28, or 48.

E183223-A75-UL

Switching Power Adaptor

GS25B17, GSwxy, where w=18 or 25, x=B or U and y can be 03, 05, 07, 09, 12, 15, 18, 24, 28 or 48.

E183223-A77-UL

AC/DC Switching Adapter

GS12Uy (y can be 05, 07, 09, 12, 15, 18 or 24 and denotes the output rating)

E183223-A89-UL

Switching Adapter GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS40A18, GS40A24, GS40A48 GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48

E183223-A92-UL

Switching Adaptor GS90Ax, where x can be 12, 15, 19, 24, 48 E183223-A97-UL Switching Mode Power Supply

GS220AX, (X = 12, 15, 20, 24, 48), GS220A48-AG1 E183223-A113-UL

AC/DC SWITCHING ADAPTOR

GS160AX (X=12,15,20,24,48) E183223-A122-UL

AC/DC SWITCHING ADAPTOR

GS120AX (X=12, 15, 20, 24, 48) E183223-A124-UL

Issue Date: 2010-05-19 Page 1 of 14 Report Reference # E183223-A92-UL

2011-09-28

Copyright © 2011

UL TEST REPORT AND PROCEDURE Standard: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology

Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03 (Information Technology Equipment - Safety - Part 1: General Requirements)

Certification Type: Listing CCN: QQGQ, QQGQ7 (Power Supplies for Information Technology

Equipment Including Electrical Business Equipment)

Product: Switching Adapter Model: GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS40A18,

GS40A24, GS40A48 GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48

Rating: Input: Models GS40Ay: 100-240 Vac, 50/60 Hz, 1.0 A Models GS60Ay: 100-240 Vac, 50/60 Hz, 1.4 A Output: Model GS40A05: 5 Vdc, 5.0 A max., 25 W max. Model GS40A07: 7.5 Vdc, 5.34 A max., 40 W max. Model GS40A09: 9 Vdc, 4.45 A max., 40 W max. Model GS40A12: 12 Vdc, 3.34 A max., 40 W max. Model GS40A15: 15 Vdc, 2.67 A max., 40 W max. Model GS40A18: 18 Vdc, 2.22 A max., 40 W max. Model GS40A24: 24 Vdc, 1.67 A max., 40 W max. Model GS40A48: 48 Vdc, 0.84 A max., 40 W max. Model GS60A05: 5 Vdc, 6.0 A max., 30 W max. Model GS60A07: 7.5 Vdc, 6.0 A max., 45 W max. Model GS60A09: 9 Vdc, 6.0 A max., 54 W max. Model GS60A12: 12 Vdc, 5.0 A max., 60 W max. Model GS60A15: 15 Vdc, 4.0 A max., 60 W max. Model GS60A18: 18 Vdc, 3.33 A max., 60 W max. Model GS60A24: 24 Vdc, 2.5 A max., 60 W max. Model GS60A48: 48 Vdc, 1.25 A max., 60 W max.

Applicant Name and Address: MEAN WELL ENTERPRISES CO LTD 28 WUQUAN 3RD RD WUGU DIST NEW TAIPEI 248 TAIWAN

This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety.

Issue Date: 2010-05-19 Page 2 of 14 Report Reference # E183223-A92-UL

2011-09-28

Copyright © 2011

Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL.

Prepared by: Bob Hilbrecht

Underwriters Laboratories Inc.

Reviewed by: Timothy Geiger

Underwriters Laboratories Inc.

Issue Date: 2010-05-19 Page 3 of 14 Report Reference # E183223-A92-UL

2011-09-28

Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions - i. Part AC details important information which may be applicable to products covered by this Procedure.

Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report.

ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report.

iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.

Product Description

This product is a cord connected type power unit intended to be used for information technology equipment in TN power systems and are for indoor use only. It consists of an isolated transformer with electronic circuitry housed in a thermoplastic enclosure. It is also provided with appliance inlet for input connection and a length of cord terminated with a molded-on non-standard polarized output connector for output connection.

Model Differences

Models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS40A18, GS40A24, GS40A48 are identical to each other except for output rating and secondary winding of transformer. Models GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 are identical to each other except for output rating and secondary winding of transformer. Models GS40Ay and GS60Ay are identical except for transformer.

Technical Considerations

Equipment mobility : movable

Connection to the mains : pluggable A

Operating condition : continuous

Access location : operator accessible

Over voltage category (OVC) : OVC II

Mains supply tolerance (%) or absolute mains supply values : +10%, -10%

Tested for IT power systems : No

IT testing, phase-phase voltage (V) : N/A

Issue Date: 2010-05-19 Page 4 of 14 Report Reference # E183223-A92-UL

2011-09-28

Class of equipment : Class I (earthed)

Considered current rating (A) : 20A

Pollution degree (PD) : PD 2

IP protection class : IP X0

Altitude of operation (m) : 2000m

Altitude of test laboratory (m) : >2000m

Mass of equipment (kg) : < 18

The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer’s specification of: 40°C

The means of connection to the mains supply is: Pluggable A, Detachable power cord

The product is intended for use on the following power systems: TN

The equipment disconnect device is considered to be: Appliance inlet

The following accessible locations (with circuit/schematic designation) are within a limited current circuit: Vout (+ to -)

The following circuit locations (with circuit/schematic designation) were investigated as a limited power source (LPS): Vout (+ to -)

Additional Information

E183223-A92-UL, Revision: Alternate plastic material of enclosure, Sabic Plastic, Model 945.

Markings and instructions

Clause Title Marking or Instruction Details

Power rating - Ratings Ratings (voltage, frequency/dc, current)

Power rating - Model

Model Number

Power rating -

Listee's or Recognized company's name, Trade Name, Trademark or File

Issue Date: 2010-05-19 Page 5 of 14 Report Reference # E183223-A92-UL

2011-09-28

Company identification

Number

Fuses - Rating Rated current and voltage and type located on or adjacent to fuse or fuseholder.

Fuses - Non-operator access/soldered-in fuses

Unambiguous reference to service documentation for instructions for replacement of fuses replaceable only by service personnel

LPS Marking "Optionally marked with "LPS" or "Limited Power Source" on the unit."

Special Instructions to UL Representative

N/A Production-Line Testing Requirements

Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for further information.

Model Component Removable

Parts Test probe location V

rms V dc Test Time,

s

N/A --- --- --- --- --- ---

Earthing Continuity Test Exemptions - This test is not required for the following models:

N/A

Electric Strength Test Exemptions - This test is not required for the following models:

N/A

Electric Strength Test Component Exemptions - The following solid-state components may disconnected from the remainder of the circuitry during the performance of this test:

N/A

Sample and Test Specifics for Follow-Up Tests at UL

Model Component Material Test Sample(s) Test

Specifics

N/A --- --- --- --- ---

Issue Date: 2010-05-19 Page 6 of 14 Report Reference # E183223-A92-UL

2011-09-28

TABLE: List of Critical Components

Object/part or Description

Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

Enclosure Sabic Innovative Plastics Japan L L C

940(f1) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL

Enclosure (Alternate) Sabic Innovative Plastics US L L C

945(GG) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL

Enclosure (Alternate) Sabic Innovative Plastics Japan L L C

945(GG) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL

Enclosure (Alternate) Sabic Innovative Plastics B V

945(GG) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL

Appliance Inlet Various Various Rated minimum 10 A, 250 Vac. Rated minimum 70 degree C. Grounded type, ground terminal directly soldered to earth trace on PWB.

AXUT2, AXUT8 UL

Output Cord Various Various Maximum 3.05 m, marked VW-1 or FT-1, terminates with a polarized connector outside enclosure.

AVLV2, AVLV8 UL

Output Cord Strain Relief

Various Various PVC bushing integrally molded on output cord. Provided when Output Cord provided.

QMFZ2 UL

Insulating Tubing/Sleeving

Various Various FEP, PTFE, PVC, TFE, neoprene, or marked VW-1; 105 degree C, 300 V, min. 0.4 mm thick. See Table 2.10.3, Supplementary Info, for safety relevant locations.

UZFT2, UDPU2, YDTU2

UL

Printed Wiring Board Various Various Rated minimum V-1, minimum 130 degree C. See Table 2.10.3, Supplementary Info, for safety relevant locations.

ZPMV2 UL

Fuse (FS1) Various Various T2 A, 250 Vac. JDYX, JDYX7 UL Fuse (FS1) (Alternate) Conquer Electronics

Co., Ltd. MST T2 A, 250 Vac. JDYX2, JDYX8 UL

Thermistor (RTH1) Various Various NTC, rated minimum 3 A, maximum 20 ohms, at 25 -- --

Issue Date: 2010-05-19 Page 7 of 14 Report Reference # E183223-A92-UL

2011-09-28

Object/part or Description

Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

(Optional) degree C. Line Choke (LF1) (Optional)

Various TR-732 Open type construction. Rated minimum 130 degree C.

-- --

Core (LF1) Various Various Ferrite, toroidal, measured overall 9 mm OD by 5 mm ID by 3 mm wide.

-- --

Coil (LF1) Various Various Rated minimum 130 degree C. OBMW2 UL Triple Insulated Winding Wire (LF1)

Various Various Rated minimum 130 degree C. OBJT2 UL

X-Capacitor (C1) (Optional)

ARCOTRONICS SPA

R.46 Rated maximum 0.47 µF, minimum 250 Vac, 110 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional)(Alternate)

ARCOTRONICS SPA

R.49 Rated maximum 0.47 uF, minimum 250 Vac, 110 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

EPCOS ELECTRONIC COMPONENTS S A

B3292 series Rated maximum 0.47 uF, minimum 250 Vac, 105 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

ISKRA KONDENZATORJI D D

KNB1530 Rated maximum 0.47 uF minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

ISKRA KONDENZATORJI D D

KNB1560 Rated maximum 0.47 uF, minimum 250 Vac, 125 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

LIOW GU ELECTRONICS INDUSTRY CO LTD

GS-L Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) PILKOR PCX2 335M Rated maximum 0.47 uF, minimum 250 Vac, 105 FOWX2, FOWX8 UL

Issue Date: 2010-05-19 Page 8 of 14 Report Reference # E183223-A92-UL

2011-09-28

Object/part or Description

Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

(Optional) (Alternate) ELECTRONICS CO LTD

degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

X-Capacitor (C1) (Optional) (Alternate)

PILKOR ELECTRONICS CO LTD

PCX2 337 Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

ULTRA TECH XIPHI ENTERPRISE CO LTD

HQX Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

VISHAY CAPACITORS BELGIUM N V

339 Rated maximum 0.47 uF, minimum 250 Vac, 105 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

CHENG TUNG INDUSTRIAL CO LTD

CTX Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

SHINY SPACE ENTERPRISE CO LTD

SX1 Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bleeder Resistors (R1, R2)

Various Various Each rated 1.5 Mohms, minimum 1/4 W. -- --

Line Choke (LF2) (Optional)

Various TR-733 Open type construction. Rated minimum 130 degree C.

-- --

Core (LF2) Various Various Ferrite, toroidal, measured overall 16 mm OD by 10 mm ID by 5 mm wide.

-- --

Coil (LF2) Various Various Rated minimum 130 degree C. OBMW2 UL Y-Capacitor (C30) (Optional)

MURATA MFG CO LTD

KX, KH Rated maximum 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to

FOWX2, FOWX8 UL

Issue Date: 2010-05-19 Page 9 of 14 Report Reference # E183223-A92-UL

2011-09-28

Object/part or Description

Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

compliance with IEC 60384-14. Y-Capacitor (C30) (Optional) (Alternate)

WALSIN TECHNOLOGY CORP

AH, AC Rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Y-Capacitor (C30) (Optional) (Alternate)

TDK-EPC CORP. CD, CS Each rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Y-Capacitor (C30) (Optional) (Alternate)

WELSON INDUSTRIAL CO LTD

WD, KL Each rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Rectifier (BD1) Various Various Rated minimum 4 A, minimum 500 V. -- -- Electrolytic Capacitor (C5)

Various Various Integral pressure relief, rated maximum 120 µF, minimum 400 V, minimum 105 degree C.

-- --

Transistor (Q1) Various Various Rated minimum 2 A, minimum 500 V. -- -- Bridge Capacitor (C31, C32) (Optional)

MURATA MFG CO LTD

KX Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Capacitor (C31, C32) (Optional) (Alternate)

WALSIN TECHNOLOGY CORP

AH Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Capacitor (C31, C32) (Optional) (Alternate)

TDK-EPC CORP. CD Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Capacitor (C31, C32) (Optional) (Alternate)

WELSON INDUSTRIAL CO LTD

WD Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Issue Date: 2010-05-19 Page 10 of 14 Report Reference # E183223-A92-UL

2011-09-28

Object/part or Description

Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

Optical Isolator (U2, U3) Sharp Corp., Electronic Components Group

PC123 Minimum 3000 V ac isolation. Double protection. FPQU2, FPQU8 UL

Optical Isolator (U2, U3) (Alternate)

Lite-On Technology Corp.

LTV-817 Minimum 3000 V ac isolation. Double protection. FPQU2, FPQU8 UL

Transformer (T1) (Models GS60Ay)

Long Sail Electronic Co., Ltd.

TF-1738, (for y=05), TF-1739 (for y=07), TF-1740 (for y=09), TF-1741 (for y=12), TF-1742 (for y=15), TF-1743 (for y=18), TF-1744 (for y=24), TF-1745 (for y=48)

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL

Transformer (T1) (Models GS60Ay) (Alternate)

Jet Signal Industries Co., Ltd.

TF-1738, (for y=05), TF-1739 (for y=07), TF-1740 (for y=09), TF-1741 (for y=12), TF-1742 (for y=15), TF-1743 (for y=18), TF-1744 (for y=24), TF-1745 (for y=48)

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL

Transformer (T1) (Models GS40Ay)

Long Sail Electronic Co., Ltd.

TF-1782 (for y=05), TF-1783 (for y=07), TF-1784 (for y=09), TF-1785 (for y=12), TF-1786 (for y=15), TF-

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL

Issue Date: 2010-05-19 Page 11 of 14 Report Reference # E183223-A92-UL

2011-09-28

Object/part or Description

Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

1787 (for y=18), TF-1788 (for y=24), TF-1789 (for y=48)

Transformer (T1) (Models GS40Ay) (Alternate)

Jet Signal Industries Co., Ltd.

TF-1782 (for y=05), TF-1783 (for y=07), TF-1784 (for y=09), TF-1785 (for y=12), TF-1786 (for y=15), TF-1787 (for y=18), TF-1788 (for y=24), TF-1789 (for y=48)

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL

Core (T1) (Models GS60Ay)

Various Various Ferrite, measured overall 32 by 22.55 by 22 mm. Provided with Insulating tape, on bottom half of Core. Outer core wrapped with insulation tape.

-- --

Core (T1) (Models GS40Ay)

Various Various Ferrite, measured overall 26.5 by 20.15 by 19 mm. Provided with Insulating tape, on bottom half of Core. Outer core wrapped with insulation tape.

-- --

Coil (T1) Various Various Rated minimum 130 degree C. OBMW2 UL Triple Insulated Winding Wire (T1)

Furukawa Electric Co., Ltd.

TEX-E Rated minimum 130 degree C. OBJT2 UL

Triple Insulated Winding Wire (T1) (Alternate)

Totoku Electric Co., Ltd.

TIW-2 Rated minimum 130 degree C. OBJT2 UL

Triple Insulated Winding Wire (T1) (Alternate)

Totoku Electric Co., Ltd.

TIW-3 Rated minimum 155 degree C. OBJT2 UL

Bobbin (T1) Sumitomo Bakelite Co., Ltd.

PM-9820, PM-9630

Rated V-0, 150 degree C, minimum 0.51 mm thick. QMFZ2 UL

Insulating Tape (T1) 3M Co. 1350-1, 1350F-1, 1350T-1

Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom

OANZ2 UL

Issue Date: 2010-05-19 Page 12 of 14 Report Reference # E183223-A92-UL

2011-09-28

Object/part or Description

Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

bobbin edge. Insulating Tape (T1) (Alternate)

Symbio Inc. 35660, 35660Y Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL

Insulating Tape (T1) (Alternate)

Bondtec Pacific Co., Ltd.

370S Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL

Varnish (T1) Hitachi Chemical Co., Ltd.

WP-2952F-2G Rated minimum 130 degree C. OBOR2 UL

Varnish (T1) (Alternate) John C Dolph Co. BC-346A Rated minimum 130 degree C. OBOR2 UL Varnish (T1) (Alternate) Elantas Electrical

Insulation Elantas PDG Inc.

468-2-7++ Rated minimum 130 degree C. OBOR2 UL

Tubing (T1) Great Holding Industrial Co., Ltd.

TFT, TFL Rated minimum 200 degree C. Provided on all exit leads.

YDPU2 UL

Tubing (T1) (Alternate) Zeus Industrial Products Inc.

TFE-TW-300 Rated minimum 200 degree C. Provided on all exit leads.

YDPU2 UL

Heat Sink (HS1) Various Various Aluminum, minimum 1 mm thick. Provided with insulation tape near secondary parts. See Enclosure for detailed dimensions.

-- --

Heat Sink (HS2) Various Various Aluminum, minimum 1.5 mm thick. Provided with insulation tape near primary parts. See Enclosure for detailed dimensions.

-- --

Insulation Tape (HS1, HS2)

Various Various Polyester tape, 0.05 mm thick, rated 130 degree C. See Enclosure for locations of tapes.

OANZ2 UL

LED Various Various Located in SELV circuit. -- -- Resistor (R42) (For Model GS40A05)

Various Various Rated minimum 0.91 ohms, minimum 2W. -- --

Resistor (R42) (For models GS40A07, GS40A12, GS40A15,

Various Various Rated minimum 0.62 ohm , minimum 2W -- --

Issue Date: 2010-05-19 Page 13 of 14 Report Reference # E183223-A92-UL

2011-09-28

Object/part or Description

Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

GS40A24,GS40A48) Resistor (R42) (For model GS40A09)

Various Various Rated minimum 0.6 ohm , minimum 2W -- --

Resistor (R42) (For model GS40A18)

Various Various Rated minimum 0.68 ohm , minimum 2W -- --

Resistor (R42) (For model GS60A05)

Various Various Rated minimum 0.91 ohm , minimum 2W -- --

Resistor (R42) (For model GS60A07)

Various Various Rated minimum 0.6 ohm , minimum 2W -- --

Resistor (R42) (For model GS60A09)

Various Various Rated minimum 0.47ohm , minimum 2W -- --

Resistor (R42) (For models GS60A12, GS60A15, GS60A18, GS60A24)

Various Various Rated minimum 0.5 ohm , minimum 2W -- --

Resistor (R42) (For model GS60A48)

Various Various Rated minimum 0.56 ohm , minimum 2W -- --

Adhesive Glue Various Various Rated minimum V-2, 105 degree C. QMFZ2 UL Label Various Various Rated minimum 80 degree C. PGDQ2 UL

Issue Date: 2010-05-19 Page 14 of 14 Report Reference # E183223-A92-UL

2011-09-28

Enclosures

Type Supplement Id Description

Photographs 3-01 Enclosure - Front View

Photographs 3-02 Enclosure - Rear View

Photographs 3-03 Internal - Top View

Photographs 3-04 PWB - Component View

Photographs 3-05 PWB - Trace View

Diagrams 4-01 Line Choke (LF1)

Diagrams 4-02 Line Choke (LF2)

Diagrams 4-03 Transformer (T1) (GS60Ay models) (Long Sail)

Diagrams 4-04 Transformer (T1) (GS60Ay models) (Jet Signal)

Diagrams 4-05 Transformer (T1) (GS40Ay models) (Long Sail)

Diagrams 4-06 Transformer (T1) (GS40Ay models) (Jet Signal)

Diagrams 4-07 Heat Sink (HS1)

Diagrams 4-08 Heat Sink (HS2)

Diagrams 4-09 Insulation Tape (HS1, HS2)

Diagrams 4-10 Strain Relief

Diagrams 4-11 Top Enclosure Drawing

Diagrams 4-12 Bottom Enclosure Drawing

Schematics + PWB 5-01 Circuit Schematic (GS60Ay models)

Schematics + PWB 5-02 Circuit Schematic (GS40Ay models)

Schematics + PWB 5-03 PWB Layout (All models)

Manuals

Miscellaneous

File E183223 Vol. X2 Sec. A92 PHO-01 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-02 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-03 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-04 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-05 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-01(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-01(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-01(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-02(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-02(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-02(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 12)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 13)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 14)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 15)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 16)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 17)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 18)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 19)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 20)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 12)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 12)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 13)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 14)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 15)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 16)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 17)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 18)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 19)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 20)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-07 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-08 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-09 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-10 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-11 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-12 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-01 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-02 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 5)Issued: 2010-05-19

Issue Date: 2010-05-19 Page 1 of 3 Report Reference # E183223-A92-UL

Revision Date: 2011-09-28 Test Record

Test Record No. 1

This is to correct the resistance of R42 in Critical Components Table only.

Issue Date: 2010-05-19 Page 2 of 3 Report Reference # E183223-A92-UL

Revision Date: 2011-09-28 Test Record

Test Record No. 2

--The manufacturer submitted representative production sample of Switching Adaptor, Models:GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48,GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 employing the alternate plastic material of enclosure, Sabic Plastic, model 945. --All tests were conducted by PSE Inc. Taiwan located at San Chung City, Taipei, Taiwan under the TPTDP program. --Only the tests checked in “List of Tests” pages were deemed necessary. --Unless otherwise indicated, all tests were conducted on Models GS60A12. --Tests performed on Model GS60A12 were considered to be representative of models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48,GS60A05, GS60A07, GS60A09, GS60A15, GS60A18, GS60A24, GS60A48. --Only limited tests were performed on Models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48,GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 employing alternate plastic material of enclosure, Sabic Plastic, model 945 due to testing previously performed on the subject unit. --Test results reported related only to the items tested.

The following tests were conducted:

Test Testing Location/Comments End Product Reference Page

General Guidelines

Power Supply Reference Page

Strain Relief (3.2.6, 4.2.1, 4.2.7)

Steady Force (4.2.1 - 4.2.4)

Impact (4.2.5, 4.2.1, Part 22 10.2)

Drop (4.2.6, 4.2.1)

Stress Relief (4.2.7, 4.2.1) Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this Test Report.

Issue Date: 2010-05-19 Page 3 of 3 Report Reference # E183223-A92-UL

Revision Date: 2011-09-28 Test Record

The following supplements are provided as a part of this Test Record. NOTE: These supplements are only available to the Applicant via the CDA system.

Type Supplement Id Description

Attachment 2-04 CRD

Datasheet 2-05 Datasheet

MS. SANDY HSU Date: 05/19/2010 MEAN WELL ENTERPRISES CO LTD Subscriber: 710861002 28 WU-CHUAN 3RD RD PartySite: 156523 WUGU INDUSTRIAL PARK File No: E183223 TAIPEI HSIEN Project No: 10CA22607 248 TAIWAN PD No: 10O20018 Type: R PO Number: 98-0891 Subject: UL Certification Documents For Applicant This authorization is effective from the date of this Notice and only for products produced at the manufacturing location(s) specified on the current Authorization Page. Records in the Follow-Up Services Procedure covering the product are identified on the Addendum and attached. Products that bear the UL Mark shall be identical to those that were evaluated by UL and found to comply with UL’s requirements. If changes in construction are discovered, appropriate action will be taken for products not in compliance and continued use of the UL Mark may be withdrawn. UL may elect to withdraw use of the UL Mark if the Applicant or Manufacturer fails to comply with UL's requirements, including ongoing compliance of the product under UL's Follow-Up Services. The contents of this Letter are intended solely for the use of UL, the Applicant and specified Manufacturers. The opinions and findings of UL represent its judgment given with due consideration to the limitations of practical operation in accordance with UL’s objectives and purposes. UL shall not incur any obligation or liability for any loss, expense or damages, including incidental, consequential or punitive damages, arising out of or in connection with the use or reliance upon the contents of this letter to anyone other

than the Applicant as provided in the agreement between UL and Applicant. Any use or reference to UL’s name or certification mark(s) by anyone other than the Applicant in accordance with the agreement is prohibited without the express written approval of UL. This material is provided on behalf of Underwriters Laboratories Inc.(UL) or any authorized licensee of UL.

The following material resulting from the investigation under the above numbers is enclosed. Document Volume Report Reference Status Date UL Test Report X2 E183223-A92-UL-2 Re-issued 05/19/10 Please file revised Authorizations, Indices, and General Inspection Instructions in place of material of like identity. New Test Reports should be filed immediately following the last Test Report. Amendments or Corrections should be filed immediately before the Test Report to which they relate. Re-issued Test Reports should be filed immediately before all material related to the Test Report that it replaces.

NOTE: Manufacturers receive only the following sub-sections of the Applicant’s complete Test Report, where applicable: Cover Page, Specific Inspection Criteria (BA through BE), Specific Technical Criteria (through section CF), Critical Components table, and Enclosures containing image supplements. Manufacturers do not receive Test Report information related to standard clause compliance or testing results. NOTE: Manufacturers that require an Initial Product Inspection (IPI) have received their copy of the Follow-Up Service Procedure, but are instructed they are not allowed to ship products bearing the UL Mark until their UL Representative has successfully conducted the Initial Production Inspection. Please review this material and report any inaccuracies to UL Canada Customer Service, PHONE: 1-866-9373ULC (1-866-937-3852), FAX: 1-416-757-8727, E-MAIL: [email protected], referring to the above Project and/or PD Numbers. This material is provided on behalf of Underwriters Laboratories Inc.(UL) or any authorized licensee of UL. c: TRT File

Issue Date: 2010-05-19 Page 1 of 3 Report Reference # E183223-A92-UL-2

Copyright © 2010

COVER PAGE FOR TEST REPORT

Product Category: Power Supplies for Information Technology Equipment Including Electrical

Business Equipment Product Category CCN: QQGQ, QQGQ7

Test Procedure: Listing Product: Switching Adapter Model/Type Reference: GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24,

GS40A48 GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48

Rating(s): Input: Models GS40Ay: 100-240 Vac, 50/60 Hz, 1.0 A Models GS60Ay: 100-240 Vac, 50/60 Hz, 1.4 A Output: Model GS40A05: 5 Vdc, 5.0 A max., 25 W max. Model GS40A07: 7.5 Vdc, 5.34 A max., 40 W max. Model GS40A09: 9 Vdc, 4.45 A max., 40 W max. Model GS40A12: 12 Vdc, 3.34 A max., 40 W max. Model GS40A15: 15 Vdc, 2.67 A max., 40 W max. Model GS60A18: 18 Vdc, 2.22 A max., 40 W max. Model GS40A24: 24 Vdc, 1.67 A max., 40 W max. Model GS40A48: 48 Vdc, 0.84 A max., 40 W max. Model GS60A05: 5 Vdc, 6.0 A max., 30 W max. Model GS60A07: 7.5 Vdc, 6.0 A max., 45 W max. Model GS60A09: 9 Vdc, 6.0 A max., 54 W max. Model GS60A12: 12 Vdc, 5.0 A max., 60 W max. Model GS60A15: 15 Vdc, 4.0 A max., 60 W max. Model GS60A18: 18 Vdc, 3.33 A max., 60 W max. Model GS60A24: 24 Vdc, 2.5 A max., 60 W max. Model GS60A48: 48 Vdc, 1.25 A max., 60 W max.

Standards: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03 (Information Technology Equipment - Safety - Part 1: General Requirements)

Applicant Name and Address:

MEAN WELL ENTERPRISES CO LTD 28 WU-CHUAN 3RD RD WUGU INDUSTRIAL PARK TAIPEI HSIEN 248 TAIWAN

Issue Date: 2010-05-19 Page 2 of 3 Report Reference # E183223-A92-UL-2

Copyright © 2010

This Report includes the following parts, in addition to this cover page:

1. Specific Inspection Criteria 2. Specific Technical Criteria 3. Clause Verdicts 4. Critical Components 5. Test Results 6. National Differences 7. Enclosures

Issue Date: 2010-05-19 Page 3 of 3 Report Reference # E183223-A92-UL-2

Copyright © 2010

This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow -Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in accordance with the Follow -Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow -Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. Any information and documentation provided to you involving UL Mark services are provided on behalf of Underwriters Laboratories Inc(ULI) or any authorized license of ULI.

Test Report By: Reviewed By:

Joyce Liang Sam Fu Project Engineer Project Engineer Underwriters Laboratories of Canada Inc. Underwriters Laboratories Taiwan Co., Ltd.

Issue Date: 2010-05-19 Page 1 of 62 Report Reference # E183223-A92-UL-2

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

SPECIFIC INSPECTION CRITERIA

BA1.0 Special Instructions to UL Representative BA1.1 N/A

BB1.0 Supporting Documentation BB1.1 The following documents located at the beginning of this Procedure supplement the requirements

of this Test Report:

A. Authorization - The Authorization page may include additional Factory Identification Code markings.

B. Generic Inspection Instructions -

i. Part AC details important information which may be applicable to products covered by this

Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report.

ii. Part AE details any requirements which may be applicable to all products covered by this

Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report.

iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the

technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.

BC1.0 Markings and instructions BC1.1 The following markings and instructions are provided as indicated. BC1.2 All clause references are from UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology

Equipment - Safety - Part 1: General Requirements).

Standard Clause

Clause Title Marking or Instruction Details

1.7.1 Power rating - Ratings

Ratings (voltage, frequency/dc, current)

Power rating - Model

Model Number

Power rating - Company identification

Listee's or Recognized company's name, Trade Name, Trademark or File Number

1.7.6 Fuses - Rating Rated current and voltage and type located on or adjacent to fuse or fuseholder.

Fuses - Non-operator access/soldered-in fuses

Unambiguous reference to service documentation for instructions for replacement of fuses replaceable only by service personnel

Other LPS Marking "Optionally marked with "LPS" or "Limited Power Source" on the unit."

Issue Date: 2010-05-19 Page 2 of 62 Report Reference # E183223-A92-UL-2

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

BD1.0 Production-Line Testing Requirements BD1.1 Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for

further information.

Test

Potential

Model Component Removable Parts Test probe location V

rms V dc Test

Time, s N/A --- --- --- --- --- ---

BD1.2 Earthing Continuity Test Exemptions - This test is not required for the following models:

N/A

BD1.3 Electric Strength Test Exemptions - This test is not required for the following models:

N/A

BD1.4 Electric Strength Test Component Exemptions - The following solid-state components may disconnected from the remainder of the circuitry during the performance of this test:

N/A

BE1.0 Sample and Test Specifics for Follow-Up Tests at UL

BE1.1 Model Component Material Test Sample(s)

Test Specifics

N/A --- --- --- --- ---

Issue Date: 2010-05-19 Page 3 of 62 Report Reference # E183223-A92-UL-2

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

SPECIFIC TECHNICAL CRITERIA

UL 60950-1:2005 (2nd Edition)

Information technology equipment - Safety - Part 1: General requirements

Report Reference No ..................... : E183223-A92-UL-2

Compiled by ................................. : Joyce Liang Reviewed by ................................. : Sam Fu Date of issue ................................ : 2010-05-19

Standards ..................................... : UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03 (Information Technology Equipment - Safety - Part 1: General Requirements)

Test procedure .............................. : Listing

Non-standard test method ............. : N/A

Test item description .................... : Switching Adapter Trademark .................................... : None

Model and/or type reference .......... : GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48 GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48

Rating(s) ...................................... : Input: Models GS40Ay: 100-240 Vac, 50/60 Hz, 1.0 A Models GS60Ay: 100-240 Vac, 50/60 Hz, 1.4 A Output: Model GS40A05: 5 Vdc, 5.0 A max., 25 W max. Model GS40A07: 7.5 Vdc, 5.34 A max., 40 W max. Model GS40A09: 9 Vdc, 4.45 A max., 40 W max. Model GS40A12: 12 Vdc, 3.34 A max., 40 W max. Model GS40A15: 15 Vdc, 2.67 A max., 40 W max. Model GS60A18: 18 Vdc, 2.22 A max., 40 W max. Model GS40A24: 24 Vdc, 1.67 A max., 40 W max. Model GS40A48: 48 Vdc, 0.84 A max., 40 W max. Model GS60A05: 5 Vdc, 6.0 A max., 30 W max. Model GS60A07: 7.5 Vdc, 6.0 A max., 45 W max. Model GS60A09: 9 Vdc, 6.0 A max., 54 W max. Model GS60A12: 12 Vdc, 5.0 A max., 60 W max. Model GS60A15: 15 Vdc, 4.0 A max., 60 W max. Model GS60A18: 18 Vdc, 3.33 A max., 60 W max. Model GS60A24: 24 Vdc, 2.5 A max., 60 W max. Model GS60A48: 48 Vdc, 1.25 A max., 60 W max.

Issue Date: 2010-05-19 Page 4 of 62 Report Reference # E183223-A92-UL-2

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

Particulars: test item vs. test requirements Equipment mobility ................................................: movable

Connection to the mains ........................................: pluggable A

Operating condition ...............................................: continuous

Over voltage category ...........................................: OVC II

Mains supply tolerance (%) ....................................: +10%, -10%

Tested for IT power systems ..................................: No

IT testing, phase-phase voltage (V) ........................: N/A

Class of equipment ...............................................: Class I (earthed)

Mass of equipment (kg) .........................................: < 18

Pollution degree ....................................................: PD 2

IP protection class .................................................: IP X0

Possible test case verdicts: - test case does not apply to the test object .............: N / A - test object does meet the requirement ..................: Pass - test object does not meet the requirement ............: Fail (acceptable only if a corresponding, less stringent

national requirement is "Pass") General remarks: - "(see Enclosure #)" refers to additional information appended to the Test Report - "(see appended table)" refers to a table appended to the Test Report - Throughout the Test Report a point is used as the decimal separator

Issue Date: 2010-05-19 Page 5 of 62 Report Reference # E183223-A92-UL-2

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

GENERAL PRODUCT INFORMATION:

CA1.0 Report Summary CA1.1 N/A

CB1.0 Product Description CB1.1 This product is a cord connected type power unit intended to be used for information technology

equipment in TN power systems and are for indoor use only. It consists of an isolated transformer with electronic ciruitry housed in a thermoplastic enclosure. It is also provided with appliance inlet for input connection and a length of cord terminated with a molded-on non-standard polarized output connector for output connection.

CC1.0 Model Differences CC1.1 Models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48

are identical to each other except for output rating and secondary winding of transformer. Models GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 are identical to each other except for output rating and secondary winding of transformer. Models GS40Ay and GS60Ay are identical except for transformer.

CD1.0 Additional Information CD1.1 N/A

CE1.0 Technical Considerations CE1.2 The product was submitted and evaluated for use at the maximum ambient temperature (Tma)

permitted by the manufacturer’s specification of: 40°C CE1.3 The means of connection to the mains supply is: Pluggable A, Detachable power cord CE1.4 The product is intended for use on the following power systems: TN CE1.5 The equipment disconnect device is considered to be: Appliance inlet CE1.8 The following accessible locations (with circuit/schematic designation) are within a limited current

circuit: Vout (+ to -) CE1.9 The following circuit locations (with circuit/schematic designation) were investigated as a limited

power source (LPS): Vout (+ to -)

Issue Date: 2010-05-19 Page 6 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

1 GENERAL Pass

1.5 Components Pass

1.5.1 General Pass

Comply with IEC 60950 or relevant component standard

(See Critical Component List) Pass

1.5.2 Evaluation and testing of components Certified components are used in accordance with their ratings, certifications and they comply with applicable parts of this Standard. Components not certified are used in accordance with their ratings and they comply with applicable parts of this Standard and the relevant component Standard. Components, for which no relevant IEC Standard exist, have been tested under the condition occurring in the equipment, using applicable parts of this Standard.

Pass

1.5.3 Thermal controls N/A

1.5.4 Transformers Transformers comply with relevant requirements including Annex C.

Pass

1.5.5 Interconnecting cables VW-1 or FT-1, max. 3.05 m length.

Pass

1.5.6 Capacitors bridging insulation Pass

1.5.7 Resistors bridging insulation N/A

1.5.7.1 Resistors bridging functional, basic or supplementary insulation

N/A

1.5.7.2 Resistors bridging double or reinforced insulation between a.c. mains and other circuits

N/A

1.5.7.3 Resistors bridging double or reinforced insulation between a.c. mains and antenna or coaxial cable

N/A

1.5.7.4 Accessible parts N/A

1.5.8 Components in equipment for IT power systems N/A

1.5.9 Surge suppressors None provided in equipment. N/A

Issue Date: 2010-05-19 Page 7 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

1.5.9.1 General N/A

1.5.9.2 Protection of VDRs N/A

1.5.9.3 Bridging of functional insulation by a VDR N/A

1.5.9.4 Bridging of basic insulation by a VDR N/A

1.5.9.5 Bridging of supplementary, double or reinforced insulation by a VDR

N/A

1.6 Power interface Pass

1.6.1 AC power distribution systems AC power distribution systems are classified as TN.

Pass

1.6.2 Input current The steady state input current of the equipment did not exceed the RATED CURRENT by more than 10% under NORMAL LOAD. See Test Record for details.

Pass

1.6.3 Voltage limit of hand-held equipment Not hand-held equipment . N/A

1.6.4 Neutral conductor Neutral conductor is insulated from secondary circuitry as if it were a line conductor.

Pass

Issue Date: 2010-05-19 Page 8 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

1.7 Marking and instructions Pass

1.7.1 Power rating Rating marking readily visible to operator.

Pass

Rated voltage(s) or voltage range(s) (V).............. : 100-240 Vac Pass

Symbol for nature of supply, for d.c. only............. : N/A

Rated frequency or rated frequency range (Hz)... : 50/60 Hz Pass

Rated current (mA or A)..................................... : Models GS40Ay: 1.0 A Models GS60Ay: 1.4 A

Pass

Manufacturer's name or trademark or identification mark ................................................................. :

Mean Well Enterprises Co., Ltd., or File "E183223"

Pass

Model identification or type reference.................. : GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48 GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48

Pass

Symbol for Class II equipment only ..................... : Class I equipment. N/A

Other markings and symbols .............................. : Additional marking may be provided when submitted for national approval.

Pass

1.7.2 Safety instructions and marking Operating/safety instructions made available to the user.

Pass

1.7.2.1 General Pass

1.7.2.2 Disconnect devices Appliance inlet provided. N/A

1.7.2.3 Overcurrent protective device Pluggable Type A equipment. N/A

1.7.2.4 IT Power distribution systems N/A

1.7.2.5 Operator access with a tool No tools used. N/A

1.7.2.6 Ozone Equipment does not produce ozone.

N/A

1.7.3 Short duty cycles N/A

1.7.4 Supply voltage adjustment ................................. : N/A

Method and means of adjustment; reference to installation instructions ....................................... :

Unit is auto-ranging. N/A

1.7.5 Power outlets on the equipment ......................... : No standard power outlets are provided.

N/A

1.7.6 Fuse identification (marking, special fusing characteristics, cross-reference)......................... :

FS1: T2 A, 250 Vac marked on PWB near primary input fuses.

Pass

Issue Date: 2010-05-19 Page 9 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

1.7.7 Wiring terminals N/A

1.7.7.1 Protective earthing and bonding terminals........... : Class II equipment N/A

1.7.7.2 Terminal for a.c. mains supply conductors Not Permanently connected equipment

N/A

1.7.7.3 Terminals for d.c. mains supply conductors N/A

1.7.8 Controls and indicators N/A

1.7.8.1 Identification, location and marking ..................... : No indicator, control affecting safety provided.

N/A

1.7.8.2 Colours ............................................................. : N/A

1.7.8.3 Symbols according to IEC 60417 ........................ : There are no switches in the equipment.

N/A

1.7.8.4 Markings using figures ....................................... : Figures are not used for indicating different positions of controls.

N/A

1.7.9 Isolation of multiple power sources ..................... : There is only one connection to hazardous voltages.

N/A

1.7.10 Thermostats and other regulating devices ........... : No thermostats or similar regulating devices.

N/A

1.7.11 Durability All markings provided on UL Recognized Component labels suitable for surface they are applied upon and meet the durability test.

Pass

1.7.12 Removable parts Marking is not placed on removable parts.

Pass

1.7.13 Replaceable batteries ........................................ : No batteries provided. N/A

Language(s)...................................................... : -

1.7.14 Equipment for restricted access locations............ : N/A

Issue Date: 2010-05-19 Page 10 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

2 PROTECTION FROM HAZARDS Pass

2.1 Protection from electric shock and energy hazards Pass

2.1.1 Protection in operator access areas Pass

2.1.1.1 Access to energized parts See below Pass

Test by inspection ............................................. : Operator can not contact with any parts with hazardous voltage.

Pass

Test with test finger (Figure 2A).......................... : The test finger was unable to contact bare hazardous parts.

Pass

Test with test pin (Figure 2B).............................. : The test pin cannot touch hazardous voltage through and openings or seams of the whole enclosure.

Pass

Test with test probe (Figure 2C) ......................... : No TNV present. N/A

2.1.1.2 Battery compartments N/A

2.1.1.3 Access to ELV wiring N/A

Working voltage (Vpeak or Vrms); minimum distance through insulation (mm)........................ :

See 2.10.3 and 2.10.4 Table of clearance and creepage distance measurements.

-

2.1.1.4 Access to hazardous voltage circuit wiring N/A

2.1.1.5 Energy hazards ................................................. : The output of the power supply is not an energy hazard.

Pass

2.1.1.6 Manual controls N/A

2.1.1.7 Discharge of capacitors in equipment Pass

Measured voltage (V); time-constant (s).............. : Vpk = 352 V, Vtc = 112 V, 37% time = 900 ms.

-

2.1.1.8 Energy hazards - d.c. mains supply N/A

a) Capacitor connected to the d.c. mains supply .. : N/A

b) Internal battery connected to the mains supply : N/A

2.1.1.9 Audio amplifiers ................................................. : N/A

2.1.2 Protection in service access areas N/A

2.1.3 Protection in restricted access locations The unit is not intended to be used in restricted locations.

N/A

Issue Date: 2010-05-19 Page 11 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

2.2 SELV circuits Pass

2.2.1 General requirements Pass

2.2.2 Voltages under normal conditions (V).................. : All accessible voltages are less than 42.4 Vp or 60 V dc and are classified as SELV.

Pass

2.2.3 Voltages under fault conditions (V) ..................... : Under fault conditions voltages never exceed 71 Vp and 120 V dc and do not exceed 42.4 Vp or 60 V dc for more than 0.2 sec.

Pass

2.2.4 Connection of SELV circuits to other circuits ....... : SELV circuits are only connected to other secondary circuits. SELV circuit and all interconnected circuits separated from primary by reinforced insulation. The SELV circuit does not exceed the SELV limits under normal and fault conditions.

Pass

2.3 TNV circuits N/A

2.3.1 Limits N/A

Type of TNV circuits .......................................... : -

2.3.2 Separation from other circuits and from accessible parts

N/A

2.3.2.1 General requirements N/A

2.3.2.2 Protection by basic insulation N/A

2.3.2.3 Protection by earthing N/A

2.3.2.4 Protection by other constructions ........................ : N/A

2.3.3 Separation from hazardous voltages N/A

Insulation employed........................................... : -

2.3.4 Connection of TNV circuits to other circuits N/A

Insulation employed........................................... : -

2.3.5 Test for operating voltages generated externally N/A

Issue Date: 2010-05-19 Page 12 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

2.4 Limited current circuits Pass

2.4.1 General requirements Pass

2.4.2 Limit values Pass

Frequency (Hz) ................................................. : 60 Hz -

Measured current (mA) ...................................... : 0.465 mA -

Measured voltage (V) ........................................ : 348 Vpk -

Measured circuit capacitance (nF or uF) ............. : 0.001 uF -

2.4.3 Connection of limited current circuits to other circuits

Pass

Issue Date: 2010-05-19 Page 13 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

2.5 Limited power sources Pass

a) Inherently limited output N/A

b) Impedance limited output N/A

c) Regulating network limited output under normal operating and single fault condition

Pass

d) Overcurrent protective device limited output N/A

Max. output voltage (V), max. output current (A), max. apparent power (VA) ................................. :

Model GS60A05 Uoc: 5.18 Vdc Isc: 7.8 A VA: 37.6 VA Model GS60A18 Uoc: 18.02 Vdc Isc: 4.6 A VA: 81 VA Model GS60A48 Uoc: 48.05 Vdc Isc: 1.9 A VA: 90 VA Model GS40A05 Uoc: 5.17 Vdc Isc: 7.5 A VA: 35.6 VA Model GS40A07 Uoc: 7.63 Vdc Isc: 7.5 A VA: 53.7 VA Model GS40A12 Uoc: 12.08 Vdc Isc: 4.7 A VA: 52.7 VA Model GS40A24 Uoc: 24.01 Vdc Isc: 2.4 A VA: 56.8 VA Model GS40A48 Uoc: 48.02 Vdc Isc: 1.8 A VA: 80 VA

-

Current rating of overcurrent protective device (A): -

Issue Date: 2010-05-19 Page 14 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

Issue Date: 2010-05-19 Page 15 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

2.6 Provisions for earthing and bonding Pass

2.6.1 Protective earthing Protective earthing provided as one level of protection against electric shock.

Pass

2.6.2 Functional earthing Pass

2.6.3 Protective earthing and protective bonding conductors

Pass

2.6.3.1 General Pass

2.6.3.2 Size of protective earthing conductors Pass

Rated current (A), cross-sectional area (mm²), AWG ................................................................ :

UL approved appliance inlet rated suitable for use.

-

2.6.3.3 Size of protective bonding conductors N/A

Rated current (A), cross-sectional area mm²), AWG........................................................................ :

-

2.6.3.4 Resistance of earthing conductors and their terminations; resistance (ohm), voltage drop (V), test current (A), duration (min)............................ :

Earth terminal of appliance inlet directly soldered to PWB.

N/A

2.6.3.5 Colour of insulation ............................................ : No bonding conductors. N/A

2.6.4 Terminals Pass

2.6.4.1 General Evaluated as part of UL approved appliance inlet.

Pass

2.6.4.2 Protective earthing and bonding terminals Pass

Rated current (A), type, nominal thread diameter (mm)................................................................. :

Evaluated as part of UL approved appliance inlet.

-

2.6.4.3 Separation of the protective earthing conductor from protective bonding conductors

No Bonding Conductors provided.

N/A

2.6.5 Integrity of protective earthing Pass

2.6.5.1 Interconnection of equipment Only one equipment connected to earth.

N/A

2.6.5.2 Components in protective earthing conductors and protective bonding conductors

No switches or fuses in earthing conductors.

Pass

2.6.5.3 Disconnection of protective earth Only one equipment connected to earth.

N/A

2.6.5.4 Parts that can be removed by an operator No such parts. N/A

2.6.5.5 Parts removed during servicing N/A

2.6.5.6 Corrosion resistance Pass

2.6.5.7 Screws for protective bonding N/A

2.6.5.8 Reliance on telecommunication network or cable distribution system

N/A

Issue Date: 2010-05-19 Page 16 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

2.7 Overcurrent and earth fault protection in primary circuits Pass

2.7.1 Basic requirements Pass

Instructions when protection relies on building installation

N/A

2.7.2 Faults not covered in 5.3.7 N/A

2.7.3 Short-circuit backup protection Building installation is considered as providing short-circuit backup protection.

Pass

2.7.4 Number and location of protective devices .......... : One protective device located in the "LIVE" phase

Pass

2.7.5 Protection by several devices All protective devices are located together.

Pass

2.7.6 Warning to service personnel ............................. : N/A

2.8 Safety interlocks N/A

2.8.1 General principles N/A

2.8.2 Protection requirements N/A

2.8.3 Inadvertent reactivation N/A

2.8.4 Fail-safe operation N/A

2.8.5 Moving parts N/A

2.8.6 Overriding N/A

2.8.7 Switches and relays N/A

2.8.7.1 Contact gaps (mm) ............................................ : N/A

2.8.7.2 Overload test N/A

2.8.7.3 Endurance test N/A

2.8.7.4 Electric strength test N/A

2.8.8 Mechanical actuators N/A

Issue Date: 2010-05-19 Page 17 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

2.9 Electrical insulation Pass

2.9.1 Properties of insulating materials Natural rubber, hygroscopic materials and materials containing asbestos are not used as insulating materials. Electric strength test was conducted after the humidity treatment. See below.

Pass

2.9.2 Humidity conditioning Humidity treatment performed to 120 hrs in condition : 95%, 40°C

Pass

Relative humidity (%), temperature (°C) .............. : 95 -

2.9.3 Grade of insulation Reinforced Insulation between Primary and SELV, Basic Insulation between Primary and Earth, Functional Insulation between Primary and Primary and between SELV and SELV.

Pass

2.9.4 Separation from hazardous voltages Reinforced insulation provided between SELV and hazardous voltages.

Pass

Method(s) used ................................................. : Method 1 -

Issue Date: 2010-05-19 Page 18 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

2.10 Clearances, creepage distances and distances through insulation Pass

2.10.1 General Pollution degree 2 applicable. Pass

2.10.1.1 Frequency......................................................... : Frequencies do not exceed 30 kHz.

Pass

2.10.1.2 Pollution degrees ............................................... : Pollution Degree 2. Pass

2.10.1.3 Reduced values for functional insulation Pass

2.10.1.4 Intervening unconnected conductive parts Pass

2.10.1.5 Insulation with varying dimensions N/A

2.10.1.6 Special separation requirements N/A

2.10.1.7 Insulation in circuits generating starting pulses No starting pulses. N/A

2.10.2 Determination of working voltage See Test Record for details. Pass

2.10.2.1 General Pass

2.10.2.2 RMS working voltage See appended table. Pass

2.10.2.3 Peak working voltage See appended table. Pass

2.10.3 Clearances See appended table. Pass

2.10.3.1 General Measured distances are adequate.

Pass

2.10.3.2 Mains transient voltages Pass

a) AC mains supply ........................................... : Overvoltage Category II considered.

Pass

b) Earthed d.c. mains supplies............................ : N/A

c) Unearthed d.c.. mains supplies ....................... : N/A

d) Battery operation ........................................... : N/A

2.10.3.3 Clearances in primary circuits See appended table. Pass

2.10.3.4 Clearances in secondary circuits Functional insulation, see 5.3.4.

Pass

2.10.3.5 Clearances in circuits having starting pulses N/A

2.10.3.6 Transients from a.c. mains supply....................... : 2500 Vac Pass

2.10.3.7 Transients from d.c. mains supply....................... : N/A

2.10.3.8 Transients from telecommunication networks and cable distribution systems .................................. :

N/A

2.10.3.9 Measurement of transient voltage levels N/A

a) Transients from a mains supply N/A

For an a.c. mains supply .................................... : N/A

For a d.c. mains supply ...................................... : N/A

b) Transients from a telecommunication network N/A

Issue Date: 2010-05-19 Page 19 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

2.10.4 Creepage distances See appended table. Pass

2.10.4.1 General Pass

2.10.4.2 Material group and comparative tracking index Pass

CTI tests ........................................................... : Material group IIIb; 100 <= CTI < 175.

-

2.10.4.3 Minimum creepage distances Pass

2.10.5 Solid insulation Solid or laminated insulating materials having adequate thickness are provided.

Pass

2.10.5.1 General Pass

2.10.5.2 Distances through insulation See appended Table 2.10.5 Pass

2.10.5.3 Insulating compound as solid insulation N/A

2.10.5.4 Semiconductor devices UL approved optical isolators used for bridging reinforced insulation.

Pass

2.10.5.5 Cemented joints N/A

2.10.5.6 Thin sheet material - General Two layers used, each of which complies with the required electric strength test. Thickness 0.05 mm each.

Pass

2.10.5.7 Separable thin sheet material Pass

Number of layers (pcs)....................................... : Two layers of polyester tape provided as outer wrap on primary and secondary winding of transformer. Two layers of polyester tape provided between primary and secondary wires.

-

2.10.5.8 Non-separable thin sheet material N/A

2.10.5.9 Thin sheet material - standard test procedure N/A

Electric strength test .......................................... : -

2.10.5.10 Thin sheet material - alternative test procedure N/A

Electric strength test .......................................... : -

2.10.5.11 Insulation in wound components Pass

2.10.5.12 Wire in wound components Pass

Working voltage ................................................ : See appended table. Pass

a) Basic insulation not under stress .................... : N/A

b) Basic, supplementary, reinforced insulation..... : UL approved triple insulated winding wire used, as well as

Pass

Issue Date: 2010-05-19 Page 20 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

UL approved polyester tape provided between windings.

c) Compliance with Annex U .............................. : N/A

Two wires in contact inside wound component; angle between 45° and 90° ................................ :

Physical separation in the form of insulating sleeving provided to relieve mechanical stress at the crossover point.

Pass

2.10.5.13 Wire with solvent-based enamel in wound components

N/A

Electric strength test .......................................... : -

Routine test N/A

2.10.5.14 Additional insulation in wound components N/A

Working voltage ................................................ : N/A

- Basic insulation not under stress ...................... : N/A

- Supplementary, reinforced insulation ................ : N/A

2.10.6 Construction of printed boards Pass

2.10.6.1 Uncoated printed boards Pass

2.10.6.2 Coated printed boards No coated printed wiring boards.

N/A

2.10.6.3 Insulation between conductors on the same inner surface of a printed board

N/A

2.10.6.4 Insulation between conductors on different layers of a printed board

Pass

Distance through insulation Board is greater than 0.4 mm thick.

Pass

Number of insulation layers (pcs)........................ : 1 Layer double sided. Pass

2.10.7 Component external terminations Pass

2.10.8 Tests on coated printed boards and coated components

N/A

2.10.8.1 Sample preparation and preliminary inspection N/A

2.10.8.2 Thermal conditioning N/A

2.10.8.3 Electric strength test N/A

2.10.8.4 Abrasion resistance test N/A

2.10.9 Thermal cycling N/A

2.10.10 Test for Pollution Degree 1 environment and insulating compound

N/A

2.10.11 Tests for semiconductor devices and cemented joints

N/A

Issue Date: 2010-05-19 Page 21 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

2.10.12 Enclosed and sealed parts N/A

3 WIRING, CONNECTIONS AND SUPPLY Pass

3.1 General Pass

3.1.1 Current rating and overcurrent protection Pass

3.1.2 Protection against mechanical damage N/A

3.1.3 Securing of internal wiring N/A

3.1.4 Insulation of conductors N/A

3.1.5 Beads and ceramic insulators N/A

3.1.6 Screws for electrical contact pressure N/A

3.1.7 Insulating materials in electrical connections N/A

3.1.8 Self-tapping and spaced thread screws N/A

3.1.9 Termination of conductors Conductors suitably terminated, creepage and clearances maintained, second securing for soldered terminations provided.

Pass

10 N pull test N/A

3.1.10 Sleeving on wiring N/A

Issue Date: 2010-05-19 Page 22 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

3.2 Connection to mains supply Pass

3.2.1 Means of connection The unit is provided with an appliance inlet.

Pass

3.2.1.1 Connection to an a.c. mains supply Pass

3.2.1.2 Connection to a d.c. mains supply N/A

3.2.2 Multiple supply connections Single mains supply N/A

3.2.3 Permanently connected equipment The equipment is not permanently connected.

N/A

Number of conductors, diameter of cable and conduits (mm) ................................................... :

-

3.2.4 Appliance inlets The unit is provided with an appliance inlet.

Pass

3.2.5 Power supply cords N/A

3.2.5.1 AC power supply cords N/A

Type................................................................. : -

Rated current (A), cross-sectional area (mm²), AWG ................................................................ :

-

3.2.5.2 DC power supply cords N/A

3.2.6 Cord anchorages and strain relief Output is an LPS source. Pass

Mass of equipment (kg), pull (N)......................... : 30 N -

Longitudinal displacement (mm) ......................... : 0.01 mm -

3.2.7 Protection against mechanical damage N/A

3.2.8 Cord guards N/A

Diameter of minor dimension D (mm); test mass (g)........................................................................ :

-

Radius of curvature of cord (mm)........................ : -

3.2.9 Supply wiring space N/A

Issue Date: 2010-05-19 Page 23 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

3.3 Wiring terminals for connection of external conductors N/A

3.3.1 Wiring terminals N/A

3.3.2 Connection of non-detachable power supply cords N/A

3.3.3 Screw terminals N/A

3.3.4 Conductor sizes to be connected N/A

Rated current (A), cord/cable type, cross-sectional area (mm²) ........................................................ :

-

3.3.5 Wiring terminal sizes N/A

Rated current (A), type and nominal thread diameter (mm)................................................... :

-

3.3.6 Wiring terminals design N/A

3.3.7 Grouping of wiring terminals N/A

3.3.8 Stranded wire N/A

3.4 Disconnection from the mains supply Pass

3.4.1 General requirement Pass

3.4.2 Disconnect devices The unit is provided with an appliance inlet.

Pass

3.4.3 Permanently connected equipment Not permanently connected equipment.

N/A

3.4.4 Parts which remain energized No parts remain energized when the disconnect device is removed.

N/A

3.4.5 Switches in flexible cords No isolating switch in the cord set.

N/A

3.4.6 Number of poles - single-phase and d.c. equipment Disconnect device disconnects all poles simultaneously.

Pass

3.4.7 Number of poles - three-phase equipment The equipment is single-phased.

N/A

3.4.8 Switches as disconnect devices No such switch is provided. N/A

3.4.9 Plugs as disconnect devices N/A

3.4.10 Interconnected equipment No interconnection of hazardous voltages.

N/A

3.4.11 Multiple power sources One power source only. N/A

Issue Date: 2010-05-19 Page 24 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

3.5 Interconnection of equipment Pass

3.5.1 General requirements Output of power supply is a limited power source.

Pass

3.5.2 Types of interconnection circuits......................... : Interconnection circuits are SELV CIRCUITS.

Pass

3.5.3 ELV circuits as interconnection circuits N/A

3.5.4 Data ports for additional equipment N/A

4 PHYSICAL REQUIREMENTS Pass

4.1 Stability N/A

Angle of 10° Based on construction, the test was deemed not necessary.

N/A

Test force (N).................................................... : N/A

4.2 Mechanical strength Pass

4.2.1 General See below Pass

4.2.2 Steady force test, 10 N Pass

4.2.3 Steady force test, 30 N N/A

4.2.4 Steady force test, 250 N See Test Record for details. Pass

4.2.5 Impact test Pass

Fall test Pass

Swing test N/A

4.2.6 Drop test; height (mm) ....................................... : See Test Record for details. Pass

4.2.7 Stress relief test See Test Record for details. Pass

4.2.8 Cathode ray tubes N/A

Picture tube separately certified.......................... : N/A

4.2.9 High pressure lamps N/A

4.2.10 Wall or ceiling mounted equipment; force (N) ...... : N/A

Issue Date: 2010-05-19 Page 25 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

4.3 Design and construction Pass

4.3.1 Edges and corners All edges and corners are judged to be sufficiently well rounded so as not to constitute a hazard.

Pass

4.3.2 Handles and manual controls; force (N) .............. : N/A

4.3.3 Adjustable controls No setting for power supply voltage.

N/A

4.3.4 Securing of parts N/A

4.3.5 Connection by plugs and sockets The equipment does not have any interchangeable plugs/sockets.

N/A

4.3.6 Direct plug-in equipment N/A

Torque .............................................................. : N/A

Compliance with the relevant mains plug standard: N/A

4.3.7 Heating elements in earthed equipment N/A

4.3.8 Batteries N/A

- Overcharging of a rechargeable battery N/A

- Unintentional charging of a non-rechargeable battery

N/A

- Reverse charging of a rechargeable battery N/A

- Excessive discharging of any battery N/A

4.3.9 Oil and grease No exposure to oil and grease. N/A

4.3.10 Dust, powders, liquids and gases The equipment does not produce or employ powders, liquids, or gases.

N/A

4.3.11 Containers for liquids or gases The equipment does not contain liquid.

N/A

4.3.12 Flammable liquids ............................................. : The equipment does not use any flammable liquids.

N/A

Quantity of liquid (l)............................................ : N/A

Flash point (°C) ................................................. : N/A

4.3.13 Radiation Ionising radiation or laser or in which similar hazards are not presents.

Pass

4.3.13.1 General N/A

4.3.13.2 Ionizing radiation N/A

Measured radiation (pA/kg) ................................ : -

Issue Date: 2010-05-19 Page 26 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

Measured high-voltage (kV) ............................... : -

Measured focus voltage (kV).............................. : -

CRT markings ................................................... : -

4.3.13.3 Effect of ultraviolet (UV) radiation on materials N/A

Part, property, retention after test, flammability classification ..................................................... :

N/A

4.3.13.4 Human exposure to ultraviolet (UV) radiation....... : Only LEDs used. Pass

4.3.13.5 Laser (including LEDs) Pass

Laser class........................................................ : LEDs that are used for indicating purposes are assumed to be inherently Class 1 operating in the 400 - 700 nm wavelength range.

-

4.3.13.6 Other types ....................................................... : N/A

4.4 Protection against hazardous moving parts N/A

4.4.1 General N/A

4.4.2 Protection in operator access areas .................... : N/A

4.4.3 Protection in restricted access locations .............. : N/A

4.4.4 Protection in service access areas N/A

Issue Date: 2010-05-19 Page 27 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

4.5 Thermal requirements Pass

4.5.1 General Pass

4.5.2 Temperature tests The equipment and its component parts did not attain excessive temperatures during normal operation.

Pass

Normal load condition per Annex L ..................... : Operated in the most unfavorable way of operation given in the operating instructions until steady conditions established. Permitted rises based on manufacturer's specified Tmra of 40°C. See Test Record for details.

-

4.5.3 Temperature limits for materials Pass

4.5.4 Touch temperature limits Pass

4.5.5 Resistance to abnormal heat .............................. : N/A

4.6 Openings in enclosures N/A

4.6.1 Top and side openings N/A

Dimensions (mm) .............................................. : -

4.6.2 Bottoms of fire enclosures No openings. N/A

Construction of the bottom, dimensions (mm) ...... : -

4.6.3 Doors or covers in fire enclosures N/A

4.6.4 Openings in transportable equipment N/A

4.6.4.1 Constructional design measures N/A

Dimensions (mm) .............................................. : -

4.6.4.2 Evaluation measures for larger openings N/A

4.6.4.3 Use of metallized parts N/A

4.6.5 Adhesives for constructional purposes N/A

Conditioning temperature (°C), time (weeks) ....... : -

Issue Date: 2010-05-19 Page 28 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

4.7 Resistance to fire Pass

4.7.1 Reducing the risk of ignition and spread of flame Method 1: Selection and application of components and materials which minimize the possibility of ignition and spread of flame.

Pass

Method 1, selection and application of components wiring and materials

Pass

Method 2, application of all of simulated fault condition tests

N/A

4.7.2 Conditions for a fire enclosure Pass

4.7.2.1 Parts requiring a fire enclosure Components in primary and secondary circuits are provided with fire enclosure.

Pass

4.7.2.2 Parts not requiring a fire enclosure Interconnecting cable is marked "VW-1" or "FT-1"

Pass

4.7.3 Materials Pass

4.7.3.1 General See below. Pass

4.7.3.2 Materials for fire enclosures Equipment is moveable with mass less than 18 kg. Fire enclosure material is V-1 minimum.

Pass

4.7.3.3 Materials for components and other parts outside fire enclosures

Interconnecting cable is marked "VW-1" or "FT-1".

Pass

4.7.3.4 Materials for components and other parts inside fire enclosures

All internal materials are rated V-2 or better or are mounted on a PWB rated V-1 or better.

Pass

4.7.3.5 Materials for air filter assemblies No air filter assemblies. N/A

4.7.3.6 Materials used in high-voltage components No high-voltage components N/A

Issue Date: 2010-05-19 Page 29 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS Pass

5.1 Touch current and protective conductor current Pass

5.1.1 General Touch current levels did not exceed limits of Table 5A. See enclosed test record.

Pass

5.1.2 Configuration of equipment under test (EUT) Single mains connection. Pass

5.1.2.1 Single connection to an a.c. mains supply Pass

5.1.2.2 Redundant multiple connections to an a.c. mains supply

N/A

5.1.2.3 Simultaneous multiple connections to an a.c. mains supply

N/A

5.1.3 Test circuit Test circuit of Figure 5A used. Pass

5.1.4 Application of measuring instrument Measuring circuit of Annex D used.

Pass

5.1.5 Test procedure Touch current was measured from primary to enclosure and primary to output.

Pass

5.1.6 Test measurements RMS value measured. Pass

Supply voltage (V) ............................................. : 264 V ac, 60 Hz -

Measured touch current (mA) ............................. : Max 0.17 mA -

Max. allowed touch current (mA) ........................ : 0.25 mA -

Measured protective conductor current (mA) ....... : -- -

Max. allowed protective conductor current (mA) .. : -- -

5.1.7 Equipment with touch current exceeding 3,5 mA Touch current is < 0.25mA. N/A

5.1.7.1 General............................................................. : N/A

5.1.7.2 Simultaneous multiple connections to the supply N/A

5.1.8 Touch currents to telecommunication networks and cable distribution systems and from telecommunication networks

No TNV circuit. N/A

5.1.8.1 Limitation of the touch current to a telecommunication network or to a cable distribution system

No TNV circuit. N/A

Supply voltage (V) ............................................. : -

Measured touch current (mA) ............................. : -

Max. allowed touch current (mA) ........................ : -

5.1.8.2 Summation of touch currents from telecommunication networks

N/A

a) EUT with earthed telecommunication ports...... : N/A

Issue Date: 2010-05-19 Page 30 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

b) EUT whose telecommunication ports have no reference to protective earth

N/A

5.2 Electric strength Pass

5.2.1 General Based on the electric strength test the use of the insulating materials within the equipment is satisfactory.

Pass

5.2.2 Test procedure No insulation breakdown detected during the test. See Test Record for details.

Pass

Issue Date: 2010-05-19 Page 31 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

5.3 Abnormal operating and fault conditions Pass

5.3.1 Protection against overload and abnormal operation

Unit is protected by regulating circuitry and primary input fuse. See Test Record for details.

Pass

5.3.2 Motors N/A

5.3.3 Transformers Transformers are protected by primary fuse and by regulating network.

Pass

5.3.4 Functional insulation.......................................... : Functional insulation complies with the requirements (a) or (c).

Pass

5.3.5 Electromechanical components N/A

5.3.6 Audio amplifiers in ITE ....................................... : N/A

5.3.7 Simulation of faults See Test Record for details. Pass

5.3.8 Unattended equipment The equipment is not intended for unattended use.

N/A

5.3.9 Compliance criteria for abnormal operating and fault conditions

No fire, emission of molten metal or deformation was noted during the tests. Electric Strength tests performed after abnormal and fault tests.

Pass

5.3.9.1 During the tests No fire, emission of molten metal or deformation was noted during the tests.

Pass

5.3.9.2 After the tests Electric strength test performed with complying results after the tests.

Pass

6 CONNECTION TO TELECOMMUNICATION NETWORKS N/A

6.1 Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment

N/A

6.1.1 Protection from hazardous voltages N/A

6.1.2 Separation of the telecommunication network from earth N/A

6.1.2.1 Requirements N/A

Supply voltage (V) ............................................. : -

Current in the test circuit (mA)............................ : -

6.1.2.2 Exclusions ........................................................ : N/A

Issue Date: 2010-05-19 Page 32 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

6.2 Protection of equipment users from overvoltages on telecommunication networks

N/A

6.2.1 Separation requirements N/A

6.2.2 Electric strength test procedure N/A

6.2.2.1 Impulse test N/A

6.2.2.2 Steady-state test N/A

6.2.2.3 Compliance criteria N/A

6.3 Protection of the telecommunication wiring system from overheating N/A

Max. output current (A) ...................................... : -

Current limiting method...................................... : -

7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS N/A

7.1 General N/A

7.2 Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment

N/A

7.3 Protection of equipment users from overvoltages on the cable distribution system

N/A

7.4 Insulation between primary circuits and cable distribution systems

N/A

7.4.1 General N/A

7.4.2 Voltage surge test N/A

7.4.3 Impulse test N/A

Issue Date: 2010-05-19 Page 33 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

A ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE N/A

A.1 Flammability test for fire enclosures of movable equipment having a total mass exceeding 18 kg, and of stationary equipment (see 4.7.3.2)

N/A

A.1.1 Samples ........................................................... : -

Wall thickness (mm) .......................................... : -

A.1.2 Conditioning of samples; temperature (°C) .......... : N/A

A.1.3 Mounting of samples .......................................... : N/A

A.1.4 Test flame (see IEC 60695-11-3) N/A

Flame A, B, C or D ............................................ : N/A

A.1.5 Test procedure N/A

A.1.6 Compliance criteria N/A

Sample 1 burning time (s) .................................. : -

Sample 2 burning time (s) .................................. : -

Sample 3 burning time (s) .................................. : -

A.2 Flammability test for fire enclosures of movable equipment having a total mass not exceeding 18 kg, and for material and components located inside fire enclosures (see 4.7.3.2 and 4.7.3.4)

N/A

A.2.1 Samples, material.............................................. : -

Wall thickness (mm) .......................................... : -

A.2.2 Conditioning of samples; temperature (°C) .......... : N/A

A.2.3 Mounting of samples .......................................... : N/A

A.2.4 Test flame (see IEC 60695-11-4) N/A

Flame A, B or C................................................. : -

A.2.5 Test procedure N/A

A.2.6 Compliance criteria N/A

Sample 1 burning time (s) .................................. : -

Sample 2 burning time (s) .................................. : -

Sample 3 burning time (s) .................................. : -

A.2.7 Alternative test acc. to IEC 60695-11-5, cl. 5 and 9 N/A

Sample 1 burning time (s) .................................. : -

Sample 2 burning time (s) .................................. : -

Sample 3 burning time (s) .................................. : -

A.3 Hot flaming oil test (see 4.6.2) N/A

A.3.1 Mounting of samples N/A

A.3.2 Test procedure N/A

Issue Date: 2010-05-19 Page 34 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

A.3.3 Compliance criterion N/A

B ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS(see 4.7.2.2 and 5.3.2)

N/A

B.1 General requirements N/A

Position............................................................. : -

Manufacturer..................................................... : -

Type................................................................. : -

Rated values ..................................................... : -

B.2 Test conditions N/A

B.3 Maximum temperatures N/A

B.4 Running overload test N/A

B.5 Locked-rotor overload test N/A

Test duration (days)........................................... : -

Electric strength test: test voltage (V).................. : -

B.6 Running overload test for d.c. motors in secondary circuits

N/A

B.6.1 General N/A

B.6.2 Test procedure N/A

B.6.3 Alternative test procedure N/A

B.6.4 Electric strength test; test voltage (V).................. : N/A

B.7 Locked-rotor overload test for d.c. motors in secondary circuits N/A

B.7.1 General N/A

B.7.2 Test procedure N/A

B.7.3 Alternative test procedure N/A

B.7.4 Electric strength test; test voltage (V).................. : N/A

B.8 Test for motors with capacitors N/A

B.9 Test for three-phase motors N/A

B.10 Test for series motors N/A

Operating voltage (V)......................................... : -

Issue Date: 2010-05-19 Page 35 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

C ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3) Pass

Position............................................................. : T1 -

Manufacturer..................................................... : 1. Long Sail Electronic Co., Ltd. 2. Jet Signal Industries Co., Ltd.

-

Type................................................................. : Models GS60Ay TF-1738 (for y=05) TF-1739 (for y=07) TF-1740 (for y=09) TF-1741 (for y=12) TF-1742 (for y=15) TF-1743 (for y=18) TF-1744 (for y=24) TF-1745 (for y=48) Models GS40Ay TF-1782 (for y=05) TF-1783 (for y=07) TF-1784 (for y=09) TF-1785 (for y=12) TF-1786 (for y=15) TF-1787 (for y=18) TF-1788 (for y=24) TF-1789 (for y=48)

-

Rated values ..................................................... : T1 employs Class B (130C), Type SBI4.2

-

Method of protection.......................................... : Regulating Network -

C.1 Overload test See Test Record for details. Pass

C.2 Insulation Insulation complies with Clauses 2.10 and 5.2.2.

Pass

Protection from displacement of windings............ : Triple insulated wire used. Pass

D ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS (see 5.1.4)

Pass

D.1 Measuring instrument Pass

D.2 Alternative measuring instrument N/A

E ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13) N/A

Issue Date: 2010-05-19 Page 36 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

F ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES (see 2.10 and Annex G)

Pass

G ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM CLEARANCES

N/A

G.1 Clearances N/A

G.1.1 General N/A

G.1.2 Summary of the procedure for determining minimum clearances

N/A

G.2 Determination of mains transient voltage (V) N/A

G.2.1 AC mains supply ............................................... : N/A

G.2.2 Earthed d.c. mains supply .................................. : N/A

G.2.3 Unearthed d.c. mains supply .............................. : N/A

G.2.4 Battery operation............................................... : N/A

G.3 Determination of telecommunication network transient voltage (V) :......................................... :

N/A

G.4 Determination of required withstand voltage (V) N/A

G.4.1 Mains transients and internal repetitive peaks ..... : N/A

G.4.2 Transients from telecommunication networks ...... : N/A

G.4.3 Combination of transients N/A

G.4.4 Transients from cable distribution systems N/A

G.5 Measurement of transient voltages (V) N/A

G.6 Determination of minimum clearances ................ : N/A

H ANNEX H, IONIZING RADIATION (see 4.3.13) N/A

J ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6) Pass

Metal(s) used .................................................... : Suitable metal used non corrosive.

-

Issue Date: 2010-05-19 Page 37 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

K ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.8) N/A K.1 Making and breaking capacity N/A

K.2 Thermostat reliability; operating voltage (V)......... : N/A

K.3 Thermostat endurance test; operating voltage (V) : N/A

K.4 Temperature limiter endurance; operating voltage (V).................................................................... :

N/A

K.5 Thermal cut-out reliability N/A

K.6 Stability of operation N/A

L ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.2)

Pass

L.1 Typewriters N/A

L.2 Adding machines and cash registers N/A

L.3 Erasers N/A

L.4 Pencil sharpeners N/A

L.5 Duplicators and copy machines N/A

L.6 Motor-operated files N/A

L.7 Other business equipment Pass

Issue Date: 2010-05-19 Page 38 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

M ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) N/A M.1 Introduction N/A

M.2 Method A N/A

M.3 Method B N/A M.3.1 Ringing signal N/A

M.3.1.1 Frequency (Hz) ................................................. : -

M.3.1.2 Voltage (V)........................................................ : -

M.3.1.3 Cadence; time (s), voltage (V) ............................ : -

M.3.1.4 Single fault current (mA) .................................... : -

M.3.2 Tripping device and monitoring voltage ............... : N/A

M.3.2.1 Conditions for use of a tripping device or a monitoring voltage

N/A

M.3.2.2 Tripping device N/A

M.3.2.3 Monitoring voltage (V)........................................ : N/A

N ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9, 6.2.2.1, 7.3.2, 7.4.3 and Clause G.5)

N/A

N.1 ITU-T impulse test generators N/A

N.2 IEC 60065 impulse test generator N/A

P ANNEX P, NORMATIVE REFERENCES Pass

Q ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1) N/A

a) Preferred climatic categories .......................... : N/A

b) Maximum continuous voltage ......................... : N/A

c) Pulse current ................................................. : N/A

Issue Date: 2010-05-19 Page 39 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

R ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL PROGRAMMES

N/A

R.1 Minimum separation distances for unpopulated coated printed boards (see 2.10.6.2)

N/A

R.2 Reduced clearances (see 2.10.3) N/A

S ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3) N/A S.1 Test equipment N/A

S.2 Test procedure N/A

S.3 Examples of waveforms during impulse testing N/A

T ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER (see 1.1.2)

N/A

........................................................................ : -

U ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED INSULATION (see 2.10.5.4)

Pass

........................................................................ : UL approved triple insulated winding wire used.

-

V ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1) N/A V.1 Introduction N/A

V.2 TN power distribution systems N/A

Issue Date: 2010-05-19 Page 40 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

W ANNEX W, SUMMATION OF TOUCH CURRENTS N/A W.1 Touch current from electronic circuits N/A

W.1.1 Floating circuits N/A

W.1.2 Earthed circuits N/A

W.2 Interconnection of several equipments N/A

W.2.1 Isolation N/A

W.2.2 Common return, isolated from earth N/A

W.2.3 Common return, connected to protective earth N/A

X ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see clause C.1)

N/A

X.1 Determination of maximum input current N/A

X.2 Overload test procedure N/A

Y ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3) N/A Y.1 Test apparatus .................................................. : N/A

Y.2 Mounting of test samples ................................... : N/A

Y.3 Carbon-arc light-exposure apparatus .................. : N/A

Y.4 Xenon-arc light-exposure apparatus ................... : N/A

Z ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2) Pass

AA ANNEX AA, MANDREL TEST (see 2.10.5.8) N/A

Issue Date: 2010-05-19 Page 41 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

1.5.1 TABLE: list of critical components Pass

Object/part No. Manufacturer/ trademark

type/model technical data Product Category CCN(s)

Required Marks of Conformity

Supplement ID

Enclosure Sabic Innovative Plastics Japan L L C

940(f1) V-0, 120°C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL 3-01

Appliance Inlet Various Various Rated minimum 10 A, 250 Vac. Rated minimum 70°C. Grounded type, ground terminal directly soldered to earth trace on PWB.

AXUT2, AXUT8 UL 3-01

Output Cord Various Various Maximum 3.05 m, marked VW-1 or FT-1, terminates with a polarized connector outside enclosure.

AVLV2, AVLV8 UL 3-02

Output Cord Strain Relief

Various Various PVC bushing integrally molded on output cord. Provided when Output Cord provided.

QMFZ2 UL 4-10

Insulating Tubing/Sleeving

Various Various FEP, PTFE, PVC, TFE, neoprene, or marked VW-1; 105°C, 300 V, min. 0.4 mm thick. See Table 2.10.3, Supplementary Info, for safety relevant locations.

UZFT2, YDPU2, YDRY2, YDTU2

UL 3-04

Printed Wiring Board Various Various Rated minimum V-1, minimum 130ºC. See Table 2.10.3, Supplementary Info, for safety relevant locations.

ZPMV2 UL 5-03

Fuse (FS1) Various Various T2 A, 250 Vac. JDYX, JDYX7 UL 3-04 Fuse (FS1) (Alternate) Conquer Electronics MST T2 A, 250 Vac. JDYX2, JDYX8 UL 3-04

Issue Date: 2010-05-19 Page 42 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

Co., Ltd. Thermistor (RTH1) (Optional)

Various Various NTC, rated minimum 3 A, maximum 20 ohms, at 25°C.

-- -- 3-04

Line Choke (LF1) (Optional)

Various TR-732 Open type construction. Rated minimum 130°C.

-- -- 4-01

Core (LF1) Various Various Ferrite, toroidal, measured overall 9 mm OD by 5 mm ID by 3 mm wide.

-- -- 4-01

Coil (LF1) Various Various Rated minimum 130°C. OBMW2 UL 4-01 Triple Insulated Winding Wire (LF1)

Various Various Rated minimum 130°C. OBJT2 UL 4-01

X-Capacitor (C1) (Optional)

Various Various Rated maximum 0.47 µF, minimum 250 Vac, minimum 100°C. Class X1 or X2.

FOKY2, FOKY8, FOWX2, FOWX8

UL 3-04

Bleeder Resistors (R1, R2)

Various Various Each rated 1.5 Mohms, minimum 1/4 W.

-- -- 3-04

Line Choke (LF2) (Optional)

Various TR-733 Open type construction. Rated minimum 130°C.

-- -- 4-02

Core (LF2) Various Various Ferrite, toroidal, measured overall 16 mm OD by 10 mm ID by 5 mm wide.

-- -- 4-02

Coil (LF2) Various Various Rated minimum 130°C. OBMW2 UL 4-02 Y-Capacitor (C30) (Optional)

Various Various Rated maximum 4700 pF, minimum 250 Vac, minimum 100°C. Class Y1 or Y2.

FOKY2, FOKY8, FOWX2, FOWX8

UL 3-04

Bridge Rectifier (BD1) Various Various Rated minimum 4 A, minimum 500 V.

-- -- 3-04

Electrolytic Capacitor (C5)

Various Various Integral pressure relief, rated maximum 120 µF, minimum 400 V, minimum 105°C.

-- -- 3-04

Transistor (Q1) Various Various Rated minimum 2 A, minimum 500 V.

-- -- 3-04

Bridge Capacitor (C31, C32) (Optional)

Various Various Each rated maximum 1000 pF, minimum 250 Vac, minimum

FOWX2, FOWX8 UL

Issue Date: 2010-05-19 Page 43 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

100°C. Class Y1. Optical Isolator (U2, U3) Sharp Corp.,

Electronic Components Group

PC123 Minimum 3000 V ac isolation. Double protection.

FPQU2, FPQU8 UL 3-04

Optical Isolator (U2, U3) (Alternate)

Lite-On Technology Corp.

LTV-817 Minimum 3000 V ac isolation. Double protection.

FPQU2, FPQU8 UL 3-04

Transformer (T1) (Models GS60Ay)

Long Sail Electronic Co., Ltd.

TF-1738, (for y=05), TF-1739 (for y=07), TF -1740 (for y=09), TF-1741 (for y=12), TF-1742 (for y=15), TF -1743 (for y=18), TF-1744 (for y=24), TF-1745 (for y=48)

Class B (130°C) Insulation System, Type SBI4.2.

OBJY2 UL 4-03

Transformer (T1) (Models GS60Ay) (Alternate)

Jet Signal Industries Co., Ltd.

TF-1738, (for y=05), TF-1739 (for y=07), TF -1740 (for y=09), TF-1741 (for y=12), TF-1742 (for y=15), TF -1743 (for y=18), TF-1744 (for y=24), TF-1745 (for y=48)

Class B (130°C) Insulation System, Type SBI4.2.

OBJY2 UL 4-04

Transformer (T1) (Models GS40Ay)

Long Sail Electronic Co., Ltd.

TF-1782 (for y=05), TF-1783 (for y=07), TF -1784 (for y=09), TF-1785 (for y=12), TF-1786

Class B (130°C) Insulation System, Type SBI4.2.

OBJY2 UL 4-05

Issue Date: 2010-05-19 Page 44 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

(for y=15), TF -1787 (for y=18), TF-1788 (for y=24), TF-1789 (for y=48)

Transformer (T1) (Models GS40Ay) (Alternate)

Jet Signal Industries Co., Ltd.

TF-1782 (for y=05), TF-1783 (for y=07), TF -1784 (for y=09), TF-1785 (for y=12), TF-1786 (for y=15), TF -1787 (for y=18), TF-1788 (for y=24), TF-1789 (for y=48)

Class B (130°C) Insulation System, Type SBI4.2.

OBJY2 UL 4-06

Core (T1) (Models GS60Ay)

Various Various Ferrite, measured overall 32 by 22.55 by 22 mm. Provided with Insulating tape, on bottom half of Core. Outer core wrapped with insulation tape.

-- -- 4-03

Core (T1) (Models GS40Ay)

Various Various Ferrite, measured overall 26.5 by 20.15 by 19 mm. Provided with Insulating tape, on bottom half of Core. Outer core wrapped with insulation tape.

-- -- 4-05

Coil (T1) Various Various Rated minimum 130°C. OBMW2 UL 4-03 Triple Insulated Winding Wire (T1)

Furukawa Electric Co., Ltd.

TEX-E Rated minimum 130°C. OBJT2 UL 4-03

Triple Insulated Winding Wire (T1) (Alternate)

Totoku Electric Co., Ltd.

TIW-2 Rated minimum 130°C. OBJT2 UL 4-03

Triple Insulated Winding Wire (T1) (Alternate)

Totoku Electric Co., Ltd.

TIW-3 Rated minimum 155°C. OBJT2 UL 4-03

Bobbin (T1) Sumitomo Bakelite PM-9820, PM- Rated V-0, 150°C, minimum QMFZ2 UL 4-03

Issue Date: 2010-05-19 Page 45 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

Co., Ltd. 9630 0.51 mm thick. Insulating Tape (T1) 3M Co. 1350-1, 1350F-1,

1350T-1 Polyester tape, 0.05 mm thick, rated 130°C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL 4-03

Insulating Tape (T1) (Alternate)

Symbio Inc. 35660, 35660Y Polyester tape, 0.05 mm thick, rated 130°C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL 4-03

Insulating Tape (T1) (Alternate)

Bondtec Pacific Co., Ltd.

370S Polyester tape, 0.05 mm thick, rated 130°C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL 4-03

Varnish (T1) Hitachi Chemical Co., Ltd.

WP-2952F-2G Rated minimum 130°C. OBOR2 UL 4-03

Varnish (T1) (Alternate) John C Dolph Co. BC-346A Rated minimum 130°C. OBOR2 UL 4-03 Varnish (T1) (Alternate) Elantas Electrical

Insulation Elantas PDG Inc.

468-2-7++ Rated minimum 130°C. OBOR2 UL 4-03

Tubing (T1) Great Holding Industrial Co., Ltd.

TFT, TFL Rated minimum 200°C. Provided on all exit leads.

YDPU2 UL 4-03

Tubing (T1) (Alternate) Zeus Industrial Products Inc.

TFE-TW-300 Rated minimum 200°C. Provided on all exit leads.

YDPU2 UL 4-03

Heat Sink (HS1) Various Various Aluminum, minimum 1 mm thick. Provided with insulation tape near secondary parts. See Enclosure for detailed dimensions.

-- -- 4-07

Issue Date: 2010-05-19 Page 46 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

Heat Sink (HS2) Various Various Aluminum, minimum 1.5 mm thick. Provided with insulation tape near primary parts. See Enclosure for detailed dimensions.

-- -- 4-08

Insulation Tape (HS1, HS2)

Various Various Polyester tape, 0.05 mm thick, rated 130°C. See Enclosure for locations of tapes.

OANZ2 UL 4-09

LED Various Various Located in SELV circuit. -- -- 3-04 Resistor (R42) (For Model GS40A05)

Various Various Rated minimum 0.91 ohms, minimum 2W.

-- -- 3-04

Resistor (R42) (For models GS40A07, GS40A12, GS40A15, GS40A24,GS40A48)

Various Various Rated minimum 0.62 ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For model GS40A09)

Various Various Rated minimum 0.6 ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For model GS40A18)

Various Various Rated minimum 0.68 ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For model GS60A05)

Various Various Rated minimum 0.91 ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For model GS60A07)

Various Various Rated minimum 0.6 ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For model GS60A09)

Various Various Rated minimum 0.47ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For models GS60A12, GS60A15, GS60A18, GS60A24)

Various Various Rated minimum 0.5 ohm , minimum 2W

-- -- 3-04

Resistor (R42) (For model GS60A48)

Various Various Rated minimum 0.56 ohm , minimum 2W

-- -- 3-04

Adhesive Glue Various Various Rated minimum V-2, 105°C. QMFZ2 UL 3-04 Label Various Various Rated minimum 80°C. PGDQ2 UL 3-04

Issue Date: 2010-05-19 Page 47 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

1.6.2 TABLE: electrical data (in normal conditions) Pass

U (V) I (A) I rated (A) P (W) Fuse # I fuse (A) condition/status

Model GS60A09

-- -- -- -- -- --

FS1 -- 90 65.5 1220 1220 Maximum Normal Load / 50Hz FS1 1.4 100 64.9 1124 1124 Maximum Normal Load / 50Hz FS1 1.4 240 62.0 606 606 Maximum Normal Load / 50Hz FS1 -- 254 62.0 580 580 Maximum Normal Load / 50Hz FS1 -- 264 62.0 564 564 Maximum Normal Load / 50Hz FS1 -- 90 65.5 1247 1247 Maximum Normal Load / 60Hz FS1 1.4 100 64.9 1148 1148 Maximum Normal Load / 60Hz FS1 1.4 240 62.0 603 603 Maximum Normal Load / 60Hz FS1 -- 254 62.0 576 576 Maximum Normal Load / 60Hz FS1 -- 264 62.0 560 560 Maximum Normal Load / 60Hz Model GS60A12

-- -- -- -- -- --

FS1 -- 90 70.6 1296 1296 Maximum Normal Load / 50Hz FS1 1.4 100 69.9 1190 1190 Maximum Normal Load / 50Hz FS1 1.4 240 67.0 637 637 Maximum Normal Load / 50Hz FS1 -- 254 66.0 606 606 Maximum Normal Load / 50Hz FS1 -- 264 66.0 591 591 Maximum Normal Load / 50Hz FS1 -- 90 70.6 1321 1321 Maximum Normal Load / 60Hz FS1 1.4 100 69.9 1217 1217 Maximum Normal Load / 60Hz FS1 1.4 240 67.0 628 628 Maximum Normal Load / 60Hz FS1 -- 254 66.0 603 603 Maximum Normal Load / 60Hz FS1 -- 264 66.0 587 587 Maximum Normal Load / 60Hz Model GS60A18

-- -- -- -- -- --

FS1 -- 90 69.6 1284 1284 Maximum Normal Load / 50Hz FS1 1.4 100 68.9 1178 1178 Maximum Normal Load / 50Hz FS1 1.4 240 67.0 632 632 Maximum Normal Load / 50Hz FS1 -- 254 65.0 602 602 Maximum Normal Load / 50Hz FS1 -- 264 65.0 586 586 Maximum Normal Load / 50Hz FS1 -- 90 69.5 1308 1308 Maximum Normal Load / 60Hz FS1 1.4 100 68.9 1205 1205 Maximum Normal Load / 60Hz FS1 1.4 240 670 624 624 Maximum Normal Load / 60Hz FS1 -- 254 65.0 598 598 Maximum Normal Load / 60Hz FS1 -- 264 65.0 582 582 Maximum Normal Load / 60Hz Model GS60A48

-- -- -- -- -- --

FS1 -- 90 67.6 1246 1246 Maximum Normal Load / 50Hz FS1 1.4 100 66.9 1145 1145 Maximum Normal Load / 50Hz FS1 1.4 240 64.0 612 612 Maximum Normal Load / 50Hz

Issue Date: 2010-05-19 Page 48 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

FS1 -- 254 64.0 589 589 Maximum Normal Load / 50Hz FS1 -- 264 64.0 575 575 Maximum Normal Load / 50Hz FS1 -- 90 67.6 1271 1271 Maximum Normal Load / 60Hz FS1 1.4 100 67.2 1171 1171 Maximum Normal Load / 60Hz FS1 1.4 240 64.0 609 609 Maximum Normal Load / 60Hz FS1 -- 254 64.0 586 586 Maximum Normal Load / 60Hz FS1 -- 264 64.0 569 569 Maximum Normal Load / 60Hz Model GS40A07

-- -- -- -- -- --

FS1 -- 90 46.4 907 907 Maximum Normal Load / 50Hz FS1 1.0 100 46.0 842 842 Maximum Normal Load / 50Hz FS1 1.0 240 40.0 437 437 Maximum Normal Load / 50Hz FS1 -- 254 40.9 425 425 Maximum Normal Load / 50Hz FS1 -- 264 41.7 417 417 Maximum Normal Load / 50Hz FS1 -- 90 46.4 930 930 Maximum Normal Load / 60Hz FS1 1.0 100 46.0 867 867 Maximum Normal Load / 60Hz FS1 1.0 240 40.5 438 438 Maximum Normal Load / 60Hz FS1 -- 254 42.0 424 424 Maximum Normal Load / 60Hz FS1 -- 264 42.8 415 415 Maximum Normal Load / 60Hz Model GS40A12

-- -- -- -- -- --

FS1 -- 90 45.3 884 884 Maximum Normal Load / 50Hz FS1 1.0 100 44.9 820 820 Maximum Normal Load / 50Hz FS1 1.0 240 40.0 433 433 Maximum Normal Load / 50Hz FS1 -- 254 40.9 419 419 Maximum Normal Load / 50Hz FS1 -- 264 41.5 410 410 Maximum Normal Load / 50Hz FS1 -- 90 45.3 906 906 Maximum Normal Load / 60Hz FS1 1.0 100 44.9 846 846 Maximum Normal Load / 60Hz FS1 1.0 240 40.9 432 432 Maximum Normal Load / 60Hz FS1 -- 254 41.9 417 417 Maximum Normal Load / 60Hz FS1 -- 264 42.3 405 405 Maximum Normal Load / 60Hz Model GS40A24

-- -- -- -- -- --

FS1 -- 90 45.1 874 874 Maximum Normal Load / 50Hz FS1 1.0 100 44.8 813 813 Maximum Normal Load / 50Hz FS1 1.0 240 40.6 431 431 Maximum Normal Load / 50Hz FS1 -- 254 41.6 415 415 Maximum Normal Load / 50Hz FS1 -- 264 42.3 405 405 Maximum Normal Load / 50Hz FS1 -- 90 45.2 894 894 Maximum Normal Load / 60Hz FS1 1.0 100 44.8 833 833 Maximum Normal Load / 60Hz FS1 1.0 240 41.4 428 428 Maximum Normal Load / 60Hz FS1 -- 254 42.4 411 411 Maximum Normal Load / 60Hz FS1 -- 264 43.2 400 400 Maximum Normal Load / 60Hz Model GS40A

-- -- -- -- -- --

Issue Date: 2010-05-19 Page 49 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

48 FS1 -- 90 45.6 890 890 Maximum Normal Load / 50Hz FS1 1.0 100 45.1 826 829 Maximum Normal Load / 50Hz FS1 1.0 240 40.1 433 433 Maximum Normal Load / 50Hz FS1 -- 254 40.8 419 419 Maximum Normal Load / 50Hz FS1 -- 264 41.4 410 410 Maximum Normal Load / 50Hz FS1 -- 90 45.6 912 912 Maximum Normal Load / 60Hz FS1 1.0 100 45.1 852 852 Maximum Normal Load / 60Hz FS1 1.0 240 40.9 432 432 Maximum Normal Load / 60Hz FS1 -- 254 41.8 416 416 Maximum Normal Load / 60Hz FS1 -- 264 42.2 405 405 Maximum Normal Load / 60Hz

supplementary information:

Maximum Normal Load: Model GS40A07: 7.5 Vdc, 5.34 A max., 40 W max. Model GS40A12: 12 Vdc, 3.34 A max., 40 W max. Model GS40A24: 24 Vdc, 1.67 A max., 40 W max. Model GS40A48: 48 Vdc, 0.84 A max., 40 W max. Model GS60A09: 9 Vdc, 6.0 A max., 54 W max. Model GS60A12: 12 Vdc, 5.0 A max., 60 W max. Model GS60A18: 18 Vdc, 3.33 A max., 60 W max. Model GS60A48: 48 Vdc, 1.25 A max., 60 W max.

2.10.3 and 2.10.4

TABLE: clearance and creepage distance measurements Pass

Clearance (cl) and creepage distance (cr) at/of/between:

U peak (V)

U r.m.s. (V)

Required cl (mm)

cl (mm)

Required cr (mm)

cr (mm)

Line to Neutral before Fuse (FS1) (PWB Trace)

<420 <250 1.5 9.83 2.5 9.83

Under Fuse (FS1) (PWB Trace)

<420 <250 1.5 2.84 2.5 2.84

Fuse (FS1) Body <420 <250 1.5 8.96 2.5 8.96 Primary to Ground (PWB Trace)

<420 <250 2.0 1.77 2.5 1.77

Primary to Secondary, 10N, C32 (Pri) to C107 (Sec)

<420 <250 4.0 5.02 5.0 6.22

Primary to Secondary, 10N, C35 (Pri) to HS2 (Sec)

<420 <250 4.0 10.23 5.0 10.23

Primary to Secondary, Under U2, PWB Trace

<420 <250 4.0 7.61 5.0 7.61

Primary to Secondary, Under U3, PWB Trace

<420 <250 4.0 4.41 5.0 5.03

Primary to Secondary, U2, U3 Body

<420 <250 4.0 6.37 5.0 6.37

Primary to Secondary, Under C31, C32, PWB Trace

<420 <250 4.0 6.76 5.0 6.76

Primary to Secondary, C31, C32 Body

<420 <250 4.0 6.79 5.0 6.79

Primary to Secondary, Under T1, PWB Trace (Models GS40Ay)

484 272 4.2 21.25 5.6 21.25

Issue Date: 2010-05-19 Page 50 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

Primary to Secondary, Under T1, PWB Trace (Models GS60Ay)

488 283 4.2 21.25 5.8 21.25

Primary to Secondary, T1 (Models GS40Ay)

484 272 4.2 8.62 5.6 8.62

Secondary to Core, T1 (Models GS40Ay)

484 272 4.2 7.49 5.6 7.49

Primary to Secondary, T1 (Models GS60Ay)

488 283 4.2 8.44 5.8 8.44

Secondary to Core, T1 (Models GS60Ay)

488 283 4.2 6.39 5.8 6.39

supplementary information:

1) Functional insulation shorted, see 5.3.4. 2) Glued Components: LF2, C1, BD1, C5, T1 primary fly wires, T1 secondary leads, C31, C32, C105, C106, C107, RTH1. 3) Tubed Components: R42, C32 primary lead to body. 4) Insulation tape provided on HS1 near secondary components. 5) Insulation tape provided on HS2 near primary components. 6) One cut slot provided under T1, measured overall 12.81 by 7.56 by 1.0 mm. 7) Transformer (T1) core wrapped with insulation tape. 8) Transformer (T1) secondary windings are triple insulated winding wire. 9) Transformer (T1) primary windings wrapped with insulation tape minimum 3.5 mm from bottom bobbin edge. 10) Transformer (T1) all exit leads sleeved with tubing.

2.10.5 TABLE: distance through insulation measurements Pass

Distance through insulation (DTI) at/of: U peak (V)

Urms (V)

Test voltage (V)

Required DTI (mm)

DTI (mm)

Sleeving 420 250 3000 0.4 0.4

supplementary information:

Optical Isolators bridging reinforced insulation are UL approved, suitable for double protection and rated minimum 3000 V isolation voltage. Accepted per Annex P.2.

4.3.8 TABLE: Batteries N/A

The tests of 4.3.8 are applicable only when appropriate battery data is not available.

Is it possible to install the battery in a reverse polarity position?

Non-rechargeable batteries Rechargeable batteries

Discharging Un- intentional charging

Charging Discharging Reversed charging

Meas. current

Manuf. specs.

Meas. current Manuf. specs.

Meas. current

Manuf. specs.

Meas. current

Manuf. specs.

Issue Date: 2010-05-19 Page 51 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

Max. current during normal operation

Max. current during fault operation

Test results: Verdict

- Chemical leaks N/A

- Explosion of the battery N/A

- Emission of flame or expulsion of molten metal N/A

- Electric strength tests of equipment after completion of tests N/A

supplementary information:

4.5 TABLE: Thermal requirements Pass

Supply voltage (V) ..................................... : -- -- -- -- -- —

Ambient Tmin (°C) ..................................... : -- -- -- -- -- —

Ambient Tmax (°C) .................................... : -- -- -- -- -- —

Maximum measured temperature T of part/at: T (°C) allowed Tmax (°C)

Model GS60A09 90V / 60Hz (Top)

90V / 60Hz (Top) (Adjusted to 40C)

90V / 60Hz (Bottom)

90V / 60Hz (Bottom) (Adjusted to 40C)

-- --

Inlet Pin 65.8 66.0 65.7 66.0 -- 70 C30 Body 82.2 82.4 84.8 85.1 -- 100 LF1 Coil 86.4 86.6 87.5 87.8 -- 130 C1 Body 91.2 91.4 91.6 91.9 -- 100 LF2 Coil 103.2 103.4 104.8 105.1 -- 130 PWB Under RTH1 100.3 100.5 85.9 86.2 -- 130

Issue Date: 2010-05-19 Page 52 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

C5 Body 92.4 92.6 95.0 95.3 -- 105 U2 Body 93.9 94.1 91.9 92.2 -- 100 T1 Primary Coil 100.3 100.5 100.0 100.3 -- 110 T1 Secondary Coil 97.4 97.6 97.7 98.0 -- 110 T1 Core 89.2 89.4 91.9 92.2 -- 110 C31 Body 82.4 82.6 84.1 84.4 -- 100 C32 Body 81.5 81.7 84.4 84.7 -- 100 U3 Body 82.1 82.3 83.0 83.3 -- 100 HS1 Near BD1 82.8 83.0 87.7 88.0 -- 130 HS2 Near D100 109.1 109.3 107.0 107.3 -- 130 Output Wire 68.2 68.4 68.4 68.7 -- 80 Inside Enclosure 79.5 79.7 86.1 86.4 -- 120 Surface Of Enclosure 60.9 61.1 73.4 73.7 -- 95 Ambient Air 39.8 40.0 39.7 40.0 -- -- (Test Duration) 1.5 hrs -- 1.5 hrs -- -- -- Model GS60A09 264V /

60Hz (Top)

264V / 60Hz (Top) (Adjusted to 40C)

264V / 60Hz (Bottom)

264V / 60Hz (Bottom) (Adjusted to 40C)

-- --

Inlet Pin 54.5 54.8 53.8 54.2 -- 70 C30 Body 63.9 64.2 64.5 64.9 -- 100 LF1 Coil 66.0 66.3 65.4 65.8 -- 130 C1 Body 69.2 69.5 68.8 69.2 -- 100 LF2 Coil 73.4 73.7 74.0 74.4 -- 130 PWB Under RTH1 66.7 67.0 64.5 64.9 -- 130 C5 Body 74.1 74.4 75.5 75.9 -- 105 U2 Body 84.1 84.4 82.8 83.2 -- 100 T1 Primary Coil 91.7 92.0 91.0 91.4 -- 110 T1 Secondary Coil 87.7 88.0 87.3 87.7 -- 110 T1 Core 79.4 79.7 80.8 81.2 -- 110 C31 Body 73.6 73.9 74.6 75.0 -- 100 C32 Body 72.8 73.1 74.4 74.8 -- 100 U3 Body 74.7 75.0 74.7 75.1 -- 100 HS1 Near BD1 68.1 68.4 71.3 71.7 -- 130 HS2 Near D100 101.7 102.0 99.3 99.7 -- 130 Output Wire 62.8 63.1 63.9 64.3 -- 80 Inside Enclosure 68.4 68.7 72.6 73.0 -- 120 Surface Of Enclosure 56.5 56.8 63.3 63.7 -- 95 Ambient Air 39.7 40.0 39.6 40.0 -- -- (Test Duration) 1.5 hrs -- 1.5 hrs -- -- -- Model GS60A12 90V /

60Hz (Top)

90V / 60Hz (Bottom)

264V / 60Hz (Top)

264V / 60Hz (Bottom)

-- --

Inlet Pin 65.4 61.1 53.2 50.8 -- 70

Issue Date: 2010-05-19 Page 53 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

C30 Body 89.5 91.9 65.2 65.1 -- 100 LF1 Coil 94.5 93.7 67.6 65.5 -- 130 C1 Body 97.8 97.1 69.6 68.1 -- 100 LF2 Coil 114.4 116.3 74.6 74.5 -- 130 PWB Under RTH1 87.0 83.3 66.2 62.6 -- 130 C5 Body 99.8 100.7 74.3 74.2 -- 105 U2 Body 97.0 94.1 85.3 83.1 -- 100 T1 Primary Coil 97.7 98.6 85.1 85.1 -- 110 T1 Secondary Coil 97.4 97.8 85.2 84.9 -- 110 T1 Core 88.1 93.0 73.1 76.0 -- 110 C31 Body 86.2 86.6 72.4 73.4 -- 100 C32 Body 81.0 84.3 67.4 70.0 -- 100 U3 Body 86.3 85.3 74.2 73.6 -- 100 HS1 Near BD1 90.9 97.1 67.6 71.1 -- 130 HS2 Near D100 105.4 104.1 96.9 95.1 -- 130 Output Wire 69.7 68.5 62.0 62.7 -- 80 Inside Enclosure 78.6 88.1 64.0 71.1 -- 120 Surface Of Enclosure 62.3 77.2 54.0 63.5 -- 95 Ambient Air 40.3 40.1 40.3 40.2 -- -- (Test Duration) 1.5 hrs 1.5 hrs 1.5 hrs 1.5 hrs -- -- Model GS60A18 90V /

60Hz (Top)

90V / 60Hz (Top) (Adjusted to 40C)

90V / 60Hz (Bottom)

90V / 60Hz (Bottom) (Adjusted to 40C)

-- --

Inlet Pin 65.1 65.9 64.2 65.0 -- 70 C30 Body 82.6 83.4 83.2 84.0 -- 100 LF1 Coil 87.0 87.8 85.9 86.7 -- 130 C1 Body 89.8 90.6 88.5 89.3 -- 100 LF2 Coil 108.2 109.0 107.8 108.6 -- 130 PWB Under RTH1 84.8 85.6 82.8 83.6 -- 130 C5 Body 91.6 92.4 92.2 93.0 -- 105 U2 Body 88.4 89.2 86.7 87.5 -- 100 T1 Primary Coil 93.0 93.8 93.0 93.8 -- 110 T1 Secondary Coil 92.2 93.0 92.6 93.4 -- 110 T1 Core 83.3 84.1 85.7 86.5 -- 110 C31 Body 74.8 75.6 76.0 76.8 -- 100 C32 Body 76.7 77.5 78.8 79.6 -- 100 U3 Body 76.9 77.7 77.1 77.9 -- 100 HS1 Near BD1 82.8 83.6 86.3 87.1 -- 130 HS2 Near D100 90.5 91.3 87.6 88.4 -- 130 Output Wire 59.2 60.0 57.6 58.4 -- 80 Inside Enclosure 69.7 70.5 76.8 77.6 -- 120 Surface Of Enclosure 59.6 60.4 68.6 69.4 -- 95 Ambient Air 39.2 40.0 39.2 40.0 -- -- (Test Duration) 1.5 hrs -- 1.5 hrs -- -- --

Issue Date: 2010-05-19 Page 54 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

Model GS60A18 264V / 60Hz (Top)

264V / 60Hz (Top) (Adjusted to 40C)

264V / 60Hz (Bottom)

264V / 60Hz (Bottom) (Adjusted to 40C)

-- --

Inlet Pin 51.1 52.2 51.1 52.0 -- 70 C30 Body 59.1 60.2 59.7 60.6 -- 100 LF1 Coil 60.8 61.9 60.3 61.2 -- 130 C1 Body 63.4 64.5 63.5 64.4 -- 100 LF2 Coil 68.2 69.3 68.9 69.8 -- 130 PWB Under RTH1 61.6 62.7 60.3 61.2 -- 130 C5 Body 67.5 68.6 68.6 69.5 -- 105 U2 Body 77.2 78.3 77.1 78.0 -- 100 T1 Primary Coil 81.4 82.5 82.0 82.9 -- 110 T1 Secondary Coil 79.9 81.0 80.6 81.5 -- 110 T1 Core 69.6 70.7 71.8 72.7 -- 110 C31 Body 64.3 65.4 65.6 66.5 -- 100 C32 Body 64.4 65.5 66.3 67.2 -- 100 U3 Body 66.7 67.8 67.3 68.2 -- 100 HS1 Near BD1 62.7 63.8 65.5 66.4 -- 130 HS2 Near D100 82.6 83.7 80.8 81.7 -- 130 Output Wire 54.1 55.2 54.0 54.9 -- 80 Inside Enclosure 57.2 58.3 62.2 63.1 -- 120 Surface Of Enclosure 51.1 52.2 57.3 58.2 -- 95 Ambient Air 38.9 40.0 39.1 40.0 -- -- (Test Duration) 1.5 hrs -- 1.5 hrs -- -- -- Model GS60A48 90V /

60Hz (Top)

90V / 60Hz (Bottom)

264V / 60Hz (Top)

264V / 60Hz (Bottom)

-- --

Inlet Pin 62.6 61.8 50.7 50.2 -- 70 C30 Body 76.9 77.6 56.8 56.9 -- 100 LF1 Coil 85.0 83.8 60.4 59.4 -- 130 C1 Body 88.0 86.5 62.3 61.7 -- 100 LF2 Coil 97.6 97.0 63.9 64.1 -- 130 PWB Under RTH1 84.7 82.1 62.0 60.0 -- 130 C5 Body 86.3 86.1 64.0 64.2 -- 105 U2 Body 78.2 76.3 68.0 66.6 -- 100 T1 Primary Coil 85.5 85.5 74.7 74.5 -- 110 T1 Secondary Coil 83.0 83.3 74.1 74.1 -- 110 T1 Core 79.5 81.2 69.2 70.0 -- 110 C31 Body 73.6 74.1 63.8 64.1 -- 100 C32 Body 73.0 74.5 61.5 62.3 -- 100 U3 Body 75.9 75.1 66.3 65.5 -- 100 HS1 Near BD1 77.7 81.1 59.2 61.6 -- 130 HS2 Near D100 75.6 75.6 68.9 68.6 -- 130

Issue Date: 2010-05-19 Page 55 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

Output Wire 60.5 61.2 56.2 56.4 -- 80 Inside Enclosure 70.5 76.1 58.1 61.7 -- 120 Surface Of Enclosure 58.7 68.9 50.7 57.4 -- 95 Ambient Air 41.2 41.2 40.7 40.8 -- -- (Test Duration) 1.5 hrs 1.5 hrs 1.5 hrs 1.5 hrs -- -- Model GS40A07 90V /

60Hz (Top)

90V / 60Hz (Bottom)

264V / 60Hz (Top)

264V / 60Hz (Bottom)

-- --

Inlet Pin 58.8 58.3 50.9 51.2 -- 70 C30 Body 69.6 70.0 57.6 58.2 -- 100 LF1 Coil 69.9 69.9 57.0 57.3 -- 130 C1 Body 69.8 69.0 59.1 59.3 -- 100 LF2 Coil 78.7 78.9 61.9 62.3 -- 130 PWB Under RTH1 73.8 73.6 58.0 57.7 -- 130 C5 Body 74.3 73.4 64.3 64.7 -- 105 U2 Body 75.3 73.4 70.4 70.3 -- 100 T1 Primary Coil 78.6 77.4 75.4 74.9 -- 110 T1 Secondary Coil 77.6 76.6 74.2 74.0 -- 110 T1 Core 74.9 74.2 71.8 71.4 -- 110 C31 Body 64.4 64.0 61.1 60.8 -- 100 C32 Body 59.6 59.9 56.4 56.8 -- 100 U3 Body 64.9 63.6 62.0 61.2 -- 100 HS1 Near BD1 65.6 66.5 58.6 59.8 -- 130 HS2 Near D100 86.8 83.6 84.1 81.5 -- 130 Output Wire 58.1 56.9 56.1 55.5 -- 80 Inside Enclosure 62.8 64.3 58.8 60.3 -- 120 Surface Of Enclosure 53.7 57.3 51.2 54.2 -- 95 Ambient Air 40.6 40.4 40.7 40.7 -- -- (Test Duration) 1.5 hrs 1.5 hrs 1.5 hrs 1.5 hrs -- -- Model GS40A12 90V /

60Hz (Top)

90V / 60Hz (Bottom)

90V / 60Hz (Bottom) (Adjusted to 40C)

264V / 60Hz (Top)

264V / 60Hz (Bottom)

--

Inlet Pin 53.9 52.5 52.7 47.9 47.2 70 C30 Body 67.7 67.8 68.0 56.3 56.5 100 LF1 Coil 70.1 68.1 68.3 56.6 55.1 130 C1 Body 69.8 68.7 68.9 58.8 58.4 100 LF2 Coil 79.0 78.3 78.5 61.7 61.9 130 PWB Under RTH1 76.1 73.1 73.3 58.5 56.3 130 C5 Body 73.8 73.4 73.6 63.0 63.3 105 U2 Body 71.3 69.0 69.2 66.3 65.2 100 T1 Primary Coil 73.6 74.5 74.7 69.2 70.3 110 T1 Secondary Coil 73.3 74.5 74.7 69.7 71.0 110 T1 Core 70.0 71.6 71.8 65.4 67.4 110

Issue Date: 2010-05-19 Page 56 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

C31 Body 63.1 64.5 64.7 59.1 60.3 100 C32 Body 62.0 63.6 63.8 58.3 59.9 100 U3 Body 63.2 63.8 64.0 60.1 60.6 100 HS1 Near BD1 67.1 69.6 69.8 59.6 62.0 130 HS2 Near D100 75.5 75.6 75.8 72.6 73.1 130 Output Wire 55.6 56.4 56.6 64.0 54.7 80 Inside Enclosure 60.3 65.9 66.1 56.1 61.1 120 Surface Of Enclosure 52.2 60.9 61.1 50.4 57.2 95 Ambient Air 40.0 39.8 40.0 40.1 40.2 -- (Test Duration) 1.5 hrs 1.5 hrs -- 1.5 hrs 1.5 hrs -- Model GS40A24 90V /

60Hz (Top)

90V / 60Hz (Bottom)

264V / 60Hz (Top)

264V / 60Hz (Top) (Adjusted to 40C)

264V / 60Hz (Bottom)

--

Inlet Pin 53.2 52.5 46.3 47.1 46.9 70 C30 Body 66.1 66.9 54.0 54.8 55.2 100 LF1 Coil 68.8 67.5 55.1 55.9 54.5 130 C1 Body 67.5 66.6 55.9 56.7 56.4 100 LF2 Coil 77.4 77.1 58.4 59.2 59.7 130 PWB Under RTH1 74.5 72.8 56.9 57.7 55.8 130 C5 Body 71.0 70.7 59.0 59.8 60.2 105 U2 Body 68.3 66.4 63.4 64.2 62.9 100 T1 Primary Coil 71.6 72.0 67.0 67.8 68.5 110 T1 Secondary Coil 71.2 71.6 67.5 68.3 69.1 110 T1 Core 66.2 67.6 61.9 62.7 64.0 110 C31 Body 62.0 61.8 57.0 57.8 58.9 100 C32 Body 57.9 58.8 53.9 54.7 55.9 100 U3 Body 60.9 60.4 56.1 56.9 58.0 100 HS1 Near BD1 63.6 66.4 55.3 56.1 58.8 130 HS2 Near D100 69.5 67.7 67.2 68.0 66.1 130 Output Wire 52.3 51.5 50.3 51.1 50.4 80 Inside Enclosure 57.7 61.8 53.0 53.8 57.4 120 Surface Of Enclosure 51.5 58.0 48.5 49.3 54.0 95 Ambient Air 40.1 40.1 39.2 40.0 40.2 -- (Test Duration) 1.5 hrs 1.5 hrs 1.5 hrs -- 1.5 hrs -- Model GS40A48 90V /

60Hz (Top)

90V / 60Hz (Bottom)

264V / 60Hz (Top)

264V / 60Hz (Top) (Adjusted to 40C)

264V / 60Hz (Bottom)

--

Inlet Pin 55.6 56.5 48.6 48.9 49.8 70 C30 Body 63.3 64.5 52.9 53.2 54.5 100 LF1 Coil 68.4 69.3 55.3 55.6 56.3 130 C1 Body 67.2 67.7 56.2 56.5 57.5 100 LF2 Coil 76.3 76.8 58.4 58.7 59.7 130

Issue Date: 2010-05-19 Page 57 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

PWB Under RTH1 71.9 73.3 56.2 56.5 57.4 130 C5 Body 71.2 71.1 59.0 59.3 60.3 105 U2 Body 64.9 64.3 59.7 60.0 60.3 100 T1 Primary Coil 72.4 72.0 66.6 66.9 67.9 110 T1 Secondary Coil 71.6 71.3 66.5 66.8 67.7 110 T1 Core 66.9 67.0 62.5 62.8 63.4 110 C31 Body 59.7 60.0 55.2 55.5 56.5 100 C32 Body 58.5 58.5 53.5 53.8 54.7 100 U3 Body 58.6 58.5 54.5 54.8 55.9 100 HS1 Near BD1 62.5 64.0 54.0 54.3 56.1 130 HS2 Near D100 62.0 60.8 59.3 59.6 58.8 130 Output Wire 49.9 49.9 47.7 48.0 48.7 80 Inside Enclosure 57.8 59.8 52.5 52.8 54.7 120 Surface Of Enclosure 53.7 53.5 48.1 48.4 49.9 95 Ambient Air 40.1 40.3 39.7 40.0 40.7 -- (Test Duration) 1.5 hrs 1.5 hrs 1.5 hrs -- 1.5 hrs --

temperature T of winding: t1 (°C) R1 (Ω) t2 (°C) R2 ( Ω) T (°C) allowed Tmax (°C)

insulation class

-- -- -- -- -- -- -- --

supplementary information:

Maximum Normal Load: Model GS40A09: 9 Vdc, 4.45 A max., 40 W max. Model GS40A12: 12 Vdc, 3.34 A max., 40 W max. Model GS60A18: 18 Vdc, 2.22 A max., 40 W max. Model GS40A48: 48 Vdc, 0.84 A max., 40 W max. Model GS60A07: 7.5 Vdc, 6.0 A max., 45 W max. Model GS60A12: 12 Vdc, 5.0 A max., 60 W max. Model GS60A24: 24 Vdc, 2.5 A max., 60 W max. Model GS60A48: 48 Vdc, 1.25 A max., 60 W max.

4.5.5 TABLE: Ball pressure test of thermoplastic parts N/A

allowed allowed impression diameter (mm)......... : —

part test temperature (°C) impression diameter (mm)

supplementary information:

Issue Date: 2010-05-19 Page 58 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

4.7 TABLE: resistance to fire Pass

part manufacturer of material

type of material thickness (mm)

flammability class

Evidence

-- -- -- -- -- supplementary information:

See Critical Components List.

5.2 TABLE: electric strength tests, impulse tests and voltage surge tests Pass

Test voltage applied between: Voltage shape (AC, DC,

impulse, surge)

Test voltage (V)

Breakdown Yes / No

One layer of insulation (T1) AC 3000 No Primary winding to SELV winding AC 3000 No SELV winding to core AC 3000 No Primary to SELV DC 4242 No Primary to Enclosure with Foil DC 4242 No Primary to Earth DC 2500 No

supplementary information:

--

5.3 TABLE: fault condition tests Pass

ambient temperature (°C) .................................. : See Results —

Power source for EUT: Manufacturer, model/type, output rating..................................................... :

See Page 1 of Test Report —

Component No.

Fault Supply voltage

(V)

Test time Fuse #

Fuse current (A)

Observation

Model GS60A48

-- -- -- -- -- --

U2 (Pri) Short 240 10 mins FS1 0.03 Unit shutdown, NT, NB, NC. U2 (Sec) Short 240 10 mins FS1 0.03 Unit shutdown, NT, NB, NC. U2 (1) Open 240 10 mins FS1 0.03 Unit shutdown, NT, NB, NC. U3 (Pri) Short 240 10 mins FS1 0.03 Unit shutdown, NT, NB, NC. U3 (Sec) Short 240 2 hours FS1 0.6 Normal Operation, CT, NT,

NB, NC. T1 Coil = 75°C, ambient = 26°C.

U3 (1) Open 240 2 hours FS1 0.6 Normal Operation, CT, NT, NB, NC. T1 Coil = 76°C, ambient = 24°C.

BD1 Short 240 1 sec FS1 0 IP (FS1), CD (BD1), NT,

Issue Date: 2010-05-19 Page 59 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

NB, NC. C5 Short 240 1 sec FS1 0 IP (FS1), NT, NB, NC. Q1 (G-D) Short 240 1 sec FS1 0 IP (FS1), CD (Q1), NT, NB,

NC. Q1 (G-S) Short 240 10 mins FS1 0.03 Unit shutdown, NT, NB, NC. Q1 (D-S) Short 240 1 sec FS1 0 IP (FS1), CD (Q1), NT, NB,

NC. U1 (8-6) Short 240 1 sec FS1 0 IP (FS1), CD (U1), NT, NB,

NC. U1 (8-2) Short 240 1 sec FS1 0 IP (FS1), CD (U1), NT, NB,

NC. T1 (FL2-FL1)

Short 240 10 mins FS1 0.03 Unit shutdown, NT, NB, NC.

T1 (10,11,12-FL3)

Short 240 10 mins FS1 0.03 Unit shutdown, NT, NB, NC.

T1 (10,11,12 After D100)

Overload 240 7 hours FS1 0.68 Normal Output: CT at 1.25 A, Transformer Load: CT at 0.2 A, increased to 0.25 A Unit shutdown, NT, NB, NC. T1 Coil = 79°C, ambient = 25.7°C.

Vout (+ to -)

Short 240 10 mins FS1 0.03~0.04 Unit cycle protection, NT, NB, NC.

Vout (+ to -)

Overload 240 8 hours FS1 0.66 CT at 1.4 A, increased to 4.5 A Unit shutdown, NT, NB, NC. T1 Coil = 78°C, ambient = 24°C.

Model GS60A18

-- -- -- -- -- --

T1 (FL2-FL1)

Short 240 10 mins FS1 0.03 Unit shutdown, NT, NB, NC.

T1 (10,11,12-FL3)

Short 240 10 mins FS1 0.03 Unit shutdown, NT, NB, NC.

T1 (10,11,12 After D100)

Overload 240 7 hours FS1 0.73 Normal Output: CT at 3.33 A, Transformer Load: CT at 0.77 A, increased to 0.87 A Unit shutdown, NT, NB, NC. T1 Coil = 95°C, ambient = 25.7°C.

Vout (+ to -)

Short 240 10 mins FS1 0.03~0.04 Unit cycle protection, NT, NB, NC.

Vout (+ to -)

Overload 240 8 hours FS1 0.70 CT at 3.9 A, increased to 4.1 A Unit shutdown, NT, NB, NC. T1 Coil = 94°C, ambient = 24°C.

Model GS60A12

-- -- -- -- -- --

Issue Date: 2010-05-19 Page 60 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

T1 (FL2-FL1)

Short 240 10 mins FS1 0.03 Unit shutdown, NT, NB, NC.

T1 (10,11,12-FL3)

Short 240 10 mins FS1 0.03 Unit shutdown, NT, NB, NC.

T1 (10,11,12 After D100)

Overload 240 9 hours FS1 0.76 Normal Output: CT at 5.0 A, Transformer Load: CT at 1.2 A, increased to 1.5 A Unit shutdown, NT, NB, NC. T1 Coil = 101°C, ambient = 25.2°C.

Vout (+ to -)

Short 240 10 mins FS1 0.03~0.04 Unit cycle protection, NT, NB, NC.

Vout (+ to -)

Overload 240 7 hours FS1 0.69 CT at 6.2 A, increased to 6.3 A Unit shutdown, NT, NB, NC. T1 Coil = 99°C, ambient = 24.5°C.

Model GS60A09

-- -- -- -- -- --

T1 (FL2-FL1)

Short 240 10 mins FS1 0.03 Unit shutdown, NT, NB, NC.

T1 (10,11,12-FL3)

Short 240 10 mins FS1 0.03 Unit shutdown, NT, NB, NC.

T1 (10,11,12 After D100)

Overload 240 9 hours FS1 0.70 Normal Output: CT at 6.0 A, Transformer Load: CT at 1.2 A, increased to 1.3 A Unit shutdown, NT, NB, NC. T1 Coil = 105°C, ambient = 25.2°C.

Vout (+ to -)

Short 240 10 mins FS1 0.03~0.04 Unit cycle protection, NT, NB, NC.

Vout (+ to -)

Overload 240 7 hours FS1 0.66 CT at 6.8 A, increased to 7.2 A Unit shutdown, NT, NB, NC. T1 Coil = 103°C, ambient = 24.5°C.

Model GS40A07

-- -- -- -- -- --

T1 (FL2-FL1)

Short 240 10 mins FS1 0.02 Unit shutdown, NT, NB, NC.

T1 (10,11,12-FL3)

Short 240 10 mins FS1 0.02 Unit shutdown, NT, NB, NC.

T1 (10,11,12 After D100)

Overload 240 9 hours FS1 0.54 Normal Output: CT at 5.34 A, Transformer Load: CT at 1.16 A, increased to 1.36 A Unit shutdown, NT, NB, NC. T1 Coil = 84°C, ambient = 25.9°C.

Issue Date: 2010-05-19 Page 61 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

Vout (+ to -)

Short 240 10 mins FS1 0.01~0.02 Unit cycle protection, NT, NB, NC.

Vout (+ to -)

Overload 240 9 hours FS1 0.52 CT at 6.5 A, increased to 6.7 A Unit shutdown, NT, NB, NC. T1 Coil = 82°C, ambient = 29.1°C.

Model GS40A12

-- -- -- -- -- --

T1 (FL2-FL1)

Short 240 10 mins FS1 0.02 Unit shutdown, NT, NB, NC.

T1 (10,11,12-FL3)

Short 240 10 mins FS1 0.02 Unit shutdown, NT, NB, NC.

T1 (10,11,12 After D100)

Overload 240 9 hours FS1 0.52 Normal Output: CT at 3.34 A, Transformer Load: CT at 0.76 A, increased to 0.86 A Unit shutdown, NT, NB, NC. T1 Coil = 76°C, ambient = 25.9°C.

Vout (+ to -)

Short 240 10 mins FS1 0.01~0.02 Unit cycle protection, NT, NB, NC.

Vout (+ to -)

Overload 240 9 hours FS1 0.51 CT at 4.1 A, increased to 4.2 A Unit shutdown, NT, NB, NC. T1 Coil = 72°C, ambient = 29.1°C.

Model GS40A24

-- -- -- -- -- --

T1 (FL2-FL1)

Short 240 10 mins FS1 0.02 Unit shutdown, NT, NB, NC.

T1 (10,11,12-FL3)

Short 240 10 mins FS1 0.02 Unit shutdown, NT, NB, NC.

T1 (10,11,12 After D100)

Overload 240 5 hours FS1 0.51 Normal Output: CT at 1.67 A, Transformer Load: CT at 0.33 A, increased to 0.43 A Unit shutdown, NT, NB, NC. T1 Coil = 79°C, ambient = 30.2°C.

Vout (+ to -)

Short 240 10 mins FS1 0.01~0.02 Unit cycle protection, NT, NB, NC.

Vout (+ to -)

Overload 240 7 hours FS1 0.50 CT at 2 A, increased to 2.1 A Unit shutdown, NT, NB, NC. T1 Coil = 75°C, ambient = 31.1°C.

Model GS40A48

-- -- -- -- -- --

T1 (FL2-FL1)

Short 240 10 mins FS1 0.02 Unit shutdown, NT, NB, NC.

T1 Short 240 10 mins FS1 0.02 Unit shutdown, NT, NB, NC.

Issue Date: 2010-05-19 Page 62 of 62 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

Clause Requirement + Test Result - Remark Verdict

TRF No. IECEN60950_1C Underwriters Laboratories Inc.

(10,11,12-FL3) T1 (10,11,12 After D100)

Overload 240 5 hours FS1 0.47 Normal Output: CT at 0.84 A, Transformer Load: CT at 0.06 A, increased to 0. 16 A Unit shutdown, NT, NB, NC. T1 Coil = 73°C, ambient = 30.2°C.

Vout (+ to -)

Short 240 10 mins FS1 0.01~0.02 Unit cycle protection, NT, NB, NC.

Vout (+ to -)

Overload 240 7 hours FS1 0.46 CT at 0.9 A, increased to 1 A Unit shutdown, NT, NB, NC. T1 Coil = 72°C, ambient = 31.1°C.

supplementary information:

Comments Key: IP - Internal protection operated (list component) CT - Constant temperatures were obtained TW - Transformer winding opened CD - Components damaged (list damaged components) NB - No indication of dielectric breakdown YB - Dielectric breakdown (indicate time and location) NC - Cheesecloth remained intact YC - Cheesecloth charred or flamed NT - Tissue paper remained intact YT - Tissue paper charred or flamed

Issue Date: 2010-05-19 Page 1 of 10 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Enclosure National Differences

USA / Canada

Issue Date: 2010-05-19 Page 2 of 10 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

SubClause Difference + Test Result - Remark Verdict

Underwriters Laboratories Inc.

USA / Canada - Differences to IEC 60950-1:2005, Second Edition 1.1 Equipment able to be installed in accordance with

the National Electrical Code ANSI/NFPA 70 and the Canadian Electrical Code, Part1, and when applicable, the National Electrical Safety Code, IEEE C2.

Pass

1.1.1 Equipment able to be installed in accordance with ANSI/NFPA 75 and NEC Art. 645 unless intended for use outside of computer room and provided with such instructions.

Pass

1.1.2 Equipment in wire-line communication facilities serving high-voltage electric power stations operating at greater than 1kV are excluded.

N/A

1.1.2 Special requirements apply to equipment intended for use outdoors.

N/A

1.4.14 For Pluggable Equipment Type A, the protection in the installation is assumed to be 20 A.

Pass

1.5.1 All IEC standards for components identified in Annex P.1 replaced by the relevant requirements of CSA and UL component standards in Annex P.1.

Pass

1.5.1 All IEC standards for components identified in Annex P.2 alternatively satisfied by the relevant requirements of CSA and UL component standards in Annex P.2.

Pass

1.5.5 Interconnecting cables acceptable for the application regarding voltage, current, temperature, flammability, mechanical serviceability and the like.

Interconnecting cables comply with the relevant requirements of this standard.

Pass

1.5.5 For other than limited power and TNV circuits, the type of output circuit identified for output connector.

N/A

1.5.5 External cable assemblies that exceed 3.05 m in length to be types specified in the NEC and CEC.

N/A

1.5.5 Detachable external interconnecting cables 3.05 m or less in length and provided with equipment marked to identify the responsible organization and the designation for the cable.

N/A

1.5.5 Building wiring and cable for use in ducts, plenums and other air handling space subject to special requirements and excluded from scope.

N/A

1.5.5 Telephone line and extension cords and the like comply with UL 1863 and CSA C22.2 No. 233.

N/A

1.6.1.2 Equipment intended for connection to a d.c. power (mains) distribution system is subject to special

N/A

Issue Date: 2010-05-19 Page 3 of 10 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

SubClause Difference + Test Result - Remark Verdict

Underwriters Laboratories Inc.

circuit classification requirements (e.g., TNV -2)

1.6.1.2 Earthing of d.c. powered equipment provided. N/A

1.7 Lamp replacement information indicated on lampholder in operator access area.

N/A

1.7.1 Special marking format for equipment intended for use on a supply system with an earthed neutral and more than one phase conductor.

N/A

1.7.1 Equipment voltage rating not higher than rating of the plug except under special conditions.

N/A

1.7.6 Special fuse replacement marking for operator accessible fuses.

N/A

1.7.7 Identification of terminal connection of the equipment earthing conductor.

N/A

1.7.7 Connectors and field wiring terminals for external Class 2 or Class 3 circuits provided with marking indicating minimum Class of wiring to be used.

N/A

1.7.7 Marking located adjacent to terminals and visible during wiring.

N/A

2.1.1.1 Bare TNV conductive parts in the interior of equipment normally protected against contact by a cover intended for occasional removal are exempt provided instructions include directions for disconnection of TNV prior to removal of the cover.

N/A

2.3.1.b Other telecommunication signaling systems (e.g., message waiting) than described in 2.3.1(b) are subject to M.4.

N/A

2.3.1.b For TNV-2 and TNV-3 circuits with other than ringing signals and with voltages exceeding 42.4 Vp or 60 V d.c., the maximum current limit through a 2000 Ohm or greater resistor with loads disconnected is 7.1 mA peak or 30 mA d.c. under normal conditions.

N/A

2.3.1.b Limits for measurements across 5000 ohm resistor in the event of a single fault are replaced after 200 ms with the limits of M.3.1.4.

N/A

2.3.2.1 In the event of a single fault, the limits of 2.2.3 apply to SELV circuits and accessible conductive parts.

N/A

2.3.2.4 Enamel coating on signal transformer winding wire allowed as an alternative to Basic insulation in specific telecommunication applications when subjected to special construction requirements and

N/A

Issue Date: 2010-05-19 Page 4 of 10 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

SubClause Difference + Test Result - Remark Verdict

Underwriters Laboratories Inc.

routine testing.

2.5 Overcurrent protection device required for Class 2 and Class 3 limiting in accordance with the NEC, or for a Limited Power Source, not interchangeable with devices of higher ratings if operator replaceable.

N/A

2.6 Equipment having receptacles for output a.c. power connectors generated from an internal separately derived source have the earthed (grounded) circuit conductor suitably bonded to earth.

No receptacles. N/A

2.6.3.3 For Pluggable Equipment Type A, if a) b) or c) are not applicable, the current rating of the circuit is taken as 20 A

Pass

2.6.3.4 Capacity of connection between earthing terminal and parts required to be earthed subject to special conditions based on the current rating of the circuit.

N/A

2.6.3.4 Protective bonding conductors and their terminals of non-standard constructions (e.g. PWB traces) evaluated to limited short-circuit test of CSA C22.2 No.0.4.

No bonding conductors. N/A

2.6.4.1 Field wiring terminals for earthing conductors suitable for wire sizes (gauge) used in US and Canada.

N/A

2.7.1 Data for selection of special external branch circuit overcurrent devices marked on the equipment.

N/A

2.7.1 Standard supply outlets protected by overcurrent device in accordance with the NEC, and CEC, Part 1.

N/A

2.7.1 Overcurrent protection for individual transformers that distribute power to other units over branch circuit wiring.

N/A

2.7.1 Additional requirements for overcurrent protection apply to equipment provided with panelboards.

N/A

2.7.1 Non-motor-operated equipment requiring special overcurrent protective device marked with device rating.

N/A

2.10.5.12 Multi-layer winding wire subject to UL component wire requirements in addition to 2.10.5.12 and Annex U.

UL approved triple insulated winding wire used.

Pass

3.1.1 Permissible combinations of internal wiring/external cable sizes for overcurrent and short circuit protection.

Pass

Issue Date: 2010-05-19 Page 5 of 10 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

SubClause Difference + Test Result - Remark Verdict

Underwriters Laboratories Inc.

3.1.1 All interconnecting cables protected against overcurrent and short circuit.

Pass

3.2 Wiring methods permit connection of equipment to primary power supply in accordance with the NEC and CEC, Part 1.

Pass

3.2.1 Permitted use for flexible cords and plugs. N/A

3.2.1 Flexible cords provided with attachment plug rated 125% of equipment current rating.

N/A

3.2.1 Any Class II equipment provided with 15 or 20 A standard supply outlets, Edison-base lampholders or single pole disconnect device provided with a polarized type attachment plug.

N/A

3.2.1.2 Equipment intended for connection to DC mains supply power systems complies with special wiring requirements (e.g., no permanent connection to supply by flexible cord).

N/A

3.2.1.2 Equipment with one pole of the DC mains supply connected to both the equipment mains input terminal and the main protective earthing terminal provided with special instructions and construction provisions for earthing

N/A

3.2.1.2 Equipment with means for connecting supply to earthing electrode conductor has no switches or protective devices between supply connection and earthing electrode connection.

N/A

3.2.1.2 Special markings and instructions for equipment with provisions to connect earthed conductor of a DC supply circuit to earthing conductor at the equipment.

N/A

3.2.1.2 Special markings and instructions for equipment with earthed conductor of a DC supply circuit connected to the earthing conductor at the equipment.

N/A

3.2.1.2 Terminals and leads provided for permanent connection of DC powered equipment to supply marked to indicate polarity if reverse polarity may result in a hazard.

N/A

3.2.3 Permanently connected equipment has provision for connecting and securing a field wiring system (i.e. conduit, or leads etc.) per the NEC and CEC, Part 1.

N/A

3.2.3 Permanently connected equipment may have N/A

Issue Date: 2010-05-19 Page 6 of 10 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

SubClause Difference + Test Result - Remark Verdict

Underwriters Laboratories Inc.

terminals or leads not smaller than No. 18 AWG (0.82 mm²) and not less than 150 mm in length for connection of field installed wiring.

3.2.3 If supply wires exceed 60 °C, marking indicates use of 75 °C or 90 °C wiring for supply connection as appropriate.

N/A

3.2.3 Equipment compatible with suitable trade sizes of conduits and cables.

N/A

3.2.5 Length of power supply cord limited to between 1.5 and 4.5 m unless shorter length used when intended for a special installation.

N/A

3.2.5 Conductors in power supply cords sized according to NEC and CEC, Part I.

N/A

3.2.5 Power supply cords and cord sets incorporate flexible cords suitable for the particular application.

N/A

3.2.6 Strain relief provided for non-detachable interconnecting cables not supplied by a limited power source.

N/A

3.2.9 Adequate wire bending space and volume of field wiring compartment required to properly make the field connections.

N/A

3.2.9 Equipment intended solely for installation in Restricted Access Locations using low voltage d.c. systems may not need provision for connecting and securing a field wiring system. A method of securing wiring or instructions provided to ensure the wiring is protected from abuse.

N/A

3.3 Field wiring terminals provided for interconnection of units for other then LPS or Class 2 circuits also comply with 3.3.

N/A

3.3 Interconnection of units by LPS or Class 2 conductors may have field wiring connectors other than those specified in 3.3 if wiring is reliably separated.

N/A

3.3.1 Terminals for the connection of neutral conductor identified by a distinctive white marking or other equally effective means.

N/A

3.3.3 Wire binding screw terminal permitted for connection of No. 10 AWG (5.3 mm²) or smaller conductor if provided with upturned lugs, cupped washer or equivalent retention.

N/A

3.3.4 Terminals accept wire sizes (gauge) used in the N/A

Issue Date: 2010-05-19 Page 7 of 10 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

SubClause Difference + Test Result - Remark Verdict

Underwriters Laboratories Inc.

U.S. and Canada.

3.3.4 Terminals accept current-carrying conductors rated 125% of the equipment current rating.

N/A

3.3.6 Field wiring terminals marked to indicate the material(s) of the conductor appropriate for the terminals used.

N/A

3.3.6 Connection of an aluminum conductor not permitted to terminal for equipment earthing conductor.

N/A

3.3.6 Field wiring connections made through the use of suitable pressure connectors (including set screw type), solder lugs or splices to flexible leads.

N/A

3.4.2 Separate motor control device(s) required for cord-connected equipment rated more than 12 A, or with motor rated more than 1/3 hp or more than 120 V.

N/A

3.4.8 Vertically mounted disconnect devices oriented so up position of handle is "on".

N/A

3.4.11 For computer-room applications, equipment with battery systems capable of supplying 750 VA for 5 min require battery disconnect means.

N/A

4.2.8.1 Special opening restrictions for enclosures around CRTs with face dimension of 160 mm or more.

N/A

4.2.9 Compartment housing high-pressure lamp marked to indicate risk of explosion.

N/A

4.2.11 For equipment intended for mounting on racks and provided with slide/rails allowing the equipment to slide away from the rack for installation, service and maintenance, additional construction, performance and marking requirements are applicable to determine the adequacy of the slide/rails.

N/A

4.3.2 Loading test for equipment with handle(s) used to support more than 9 kg tested at four times the weight of the unit.

N/A

4.3.6 In addition to the IEC requirements, Direct Plug-in Equipment complies with UL 1310 or CSA 223 mechanical assembly requirements.

N/A

4.3.12 The maximum quantity of flammable liquid stored in equipment complies with ANSI/NFPA 30(Table NAE.6).

N/A

4.3.12 Equipment using replenishable liquids marked to indicate type of liquid to be used.

N/A

Issue Date: 2010-05-19 Page 8 of 10 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

SubClause Difference + Test Result - Remark Verdict

Underwriters Laboratories Inc.

4.3.13.2 Equipment that produces x-radiation and does not comply with 4.3.12 under all conditions of servicing marked to indicate the presence of radiation where readily visible.

N/A

4.3.13.5 Requirements contained in the applicable national codes and regulations apply to lasers (21 CFR 1040 and REDR C1370).

N/A

4.7 Automated information storage equipment intended to contain more than 0.76 m³ of combustible media requires provision for automatic sprinklers or a gaseous agent extinguishing system.

N/A

4.7.3.1 Equipment for use in environmental air space other than ducts or plenums provided with metal enclosure or with non-metallic enclosure having adequate fire-resistance and low smoke producing characteristics. Low smoke-producing characteristics evaluated according to UL 2043. Equipment for installation in space used for environmental air as described in Sec. 300-22(c) of the NEC provided with instructions indicating suitability for installation in such locations.

N/A

4.7.3.1 Flame spread rating for external surface of combustible material with exposed area greater than 0.93 m² or a single dimension greater than 1.8 m; 50 or less for computer room applications or 200 or less for other applications.

N/A

4.7.3.4 Wire marked "VW-1" or "FT-1" considered equivalent.

Pass

5.1.8.2 Special earthing provisions and instructions for equipment with high touch current due to telecommunication network connections.

N/A

5.1.8.3 Touch current due to ringing voltage for equipment containing telecommunication network leads.

N/A

5.3.7 Overloading of SELV connectors and printed wiring board receptacles accessible to the operator.

See Test Record for details. Pass

5.3.7 Tests interrupted by opening of a component repeated two additional times.

Pass

5.3.9.1 Test interrupted by opening of wire or trace subject to certain conditions.

No opening of wire or trace N/A

6 Specialized instructions provided for telephones that may be connected to a telecommunications network.

N/A

Issue Date: 2010-05-19 Page 9 of 10 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

SubClause Difference + Test Result - Remark Verdict

Underwriters Laboratories Inc.

6 Marking identifying function of telecommunication type connectors not used for connection to a telecommunication network.

N/A

6.3 Equipment remotely powered over telecommunication wiring systems provided with specialized markings adjacent to the connection.

N/A

6.3 Overcurrent protection incorporated into equipment to provide power over telecommunication wiring system not interchangeable with devices of higher ratings if operator replaceable.

N/A

6.4 Additional requirements for equipment intended for connection to a telecommunication network using cable subject to overvoltage from power line failures (Fig. 6C).

N/A

6.4 Where 26 AWG line cord required by Fig. 6C, either the cord is provided with the equipment or described in the safety instructions.

N/A

7 Equipment associated with the cable distribution system may need to be subjected to applicable parts of Chapter 8 of the NEC.

N/A

H Ionizing radiation measurements made under single fault conditions in accordance with the requirements of the Code of Federal Regulations 21 CFR 1020 and the Canadian Radiation Emitting Devices Act, REDR C1370.

N/A

M.2 Continuous ringing signals evaluated to Method A subjected to special accessibility considerations.

N/A

M.4 Special requirements for message waiting and similar telecommunications signals.

N/A

NAC Equipment intended for use with a generic secondary protector marked with suitable instructions.

N/A

NAC Equipment intended for use with a specific primary or secondary protector marked with suitable instructions.

N/A

NAD Acoustic pressure from an ear piece less than 136 dBA for short duration disturbances, and less than 125 dBA for handsets, 118 dBA for headsets, and 121 dBA for insert earphones, for long duration disturbances.

N/A

NAD Equipment connected to a telecommunication and cable distribution networks and supplied with an earphone intended to be held against, or in the ear

N/A

Issue Date: 2010-05-19 Page 10 of 10 Report Reference # E183223-A92-UL-2

IEC 60950-1:2005

SubClause Difference + Test Result - Remark Verdict

Underwriters Laboratories Inc.

is required to comply with special acoustic pressure requirements.

NAF Household/Home Office Document Shredders N/A NAF.1.7 Markings and instructions alert the user to key

safety considerations related to use of shredders, including not intended to be used by children, avoid touching document feed opening, avoid clothes and hair entanglement, and avoid aerosol products.

N/A

NAF.2.8.3 Safety interlock cannot be inadvertently activated by the articulated accessibility probe (figure NAF.1).

N/A

NAF.3.4 Provided with an isolating switch complying with 3.4.2, including 3 mm contact gap, with appropriate markings associated with the switch.

N/A

NAF.4.4 Hazardous moving parts are not accessible, as determined using the articulated accessibility probe (figure NAF.1) and the accessibility probe/wedge (figures NAF.2/NAF.3).

N/A

Issue Date: 2010-05-19 Page 1 of 6 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Enclosure Photographs

Supplement Id Description

3-01 Enclosure - Front View

3-02 Enclosure - Rear View

3-03 Internal - Top View

3-04 PWB - Component View

3-05 PWB - Trace View

Issue Date: 2010-05-19 Page 2 of 6 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Photographs ID 3-01

Issue Date: 2010-05-19 Page 3 of 6 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Photographs ID 3-02

Issue Date: 2010-05-19 Page 4 of 6 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Photographs ID 3-03

Issue Date: 2010-05-19 Page 5 of 6 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Photographs ID 3-04

Issue Date: 2010-05-19 Page 6 of 6 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Photographs ID 3-05

Issue Date: 2010-05-19 Page 1 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Enclosure Diagrams

Supplement Id Description

4-01 Line Choke (LF1)

4-02 Line Choke (LF2)

4-03 Transformer (T1) (GS60Ay models) (Long Sail)

4-04 Transformer (T1) (GS60Ay models) (Jet Signal)

4-05 Transformer (T1) (GS40Ay models) (Long Sail)

4-06 Transformer (T1) (GS40Ay models) (Jet Signal)

4-07 Heat Sink (HS1)

4-08 Heat Sink (HS2)

4-09 Insulation Tape (HS1, HS2)

4-10 Strain Relief

4-11 Top Enclosure Drawing

4-12 Bottom Enclosure Drawing

Issue Date: 2010-05-19 Page 2 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-01

Issue Date: 2010-05-19 Page 3 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-01

Issue Date: 2010-05-19 Page 4 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-01

Issue Date: 2010-05-19 Page 5 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-02

Issue Date: 2010-05-19 Page 6 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-02

Issue Date: 2010-05-19 Page 7 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-02

Issue Date: 2010-05-19 Page 8 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-03

Issue Date: 2010-05-19 Page 9 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-03

Issue Date: 2010-05-19 Page 10 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-03

Issue Date: 2010-05-19 Page 11 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-03

Issue Date: 2010-05-19 Page 12 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-03

Issue Date: 2010-05-19 Page 13 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-03

Issue Date: 2010-05-19 Page 14 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-03

Issue Date: 2010-05-19 Page 15 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-03

Issue Date: 2010-05-19 Page 16 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-03

Issue Date: 2010-05-19 Page 17 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-03

Issue Date: 2010-05-19 Page 18 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-03

Issue Date: 2010-05-19 Page 19 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 20 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 21 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 22 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 23 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 24 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 25 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 26 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 27 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 28 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 29 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 30 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 31 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 32 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 33 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 34 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 35 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 36 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 37 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 38 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Issue Date: 2010-05-19 Page 39 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-05

Issue Date: 2010-05-19 Page 40 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-05

Issue Date: 2010-05-19 Page 41 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-05

Issue Date: 2010-05-19 Page 42 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-05

Issue Date: 2010-05-19 Page 43 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-05

Issue Date: 2010-05-19 Page 44 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-05

Issue Date: 2010-05-19 Page 45 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-05

Issue Date: 2010-05-19 Page 46 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-05

Issue Date: 2010-05-19 Page 47 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-05

Issue Date: 2010-05-19 Page 48 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-05

Issue Date: 2010-05-19 Page 49 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-05

Issue Date: 2010-05-19 Page 50 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-05

Issue Date: 2010-05-19 Page 51 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 52 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 53 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 54 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 55 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 56 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 57 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 58 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 59 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 60 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 61 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 62 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 63 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 64 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 65 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 66 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 67 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 68 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 69 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 70 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Issue Date: 2010-05-19 Page 71 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-07

Issue Date: 2010-05-19 Page 72 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-08

Issue Date: 2010-05-19 Page 73 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-09

Issue Date: 2010-05-19 Page 74 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-10

Issue Date: 2010-05-19 Page 75 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-11

Issue Date: 2010-05-19 Page 76 of 76 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-12

Issue Date: 2010-05-19 Page 1 of 8 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Enclosure Schematics + PWB

Supplement Id Description

5-01 Circuit Schematic (GS60Ay models)

5-02 Circuit Schematic (GS40Ay models)

5-03 PWB Layout (All models)

Issue Date: 2010-05-19 Page 2 of 8 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Schematics ID 5-01

Issue Date: 2010-05-19 Page 3 of 8 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Schematics ID 5-02

Issue Date: 2010-05-19 Page 4 of 8 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Schematics ID 5-03

Issue Date: 2010-05-19 Page 5 of 8 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Schematics ID 5-03

Issue Date: 2010-05-19 Page 6 of 8 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Schematics ID 5-03

Issue Date: 2010-05-19 Page 7 of 8 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Schematics ID 5-03

Issue Date: 2010-05-19 Page 8 of 8 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Schematics ID 5-03

Issue Date: 2010-05-19 Page 1 of 2 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Enclosure Test Record

Description

Test Record 1

Issue Date: 2010-05-19 Page 2 of 2 Report Reference # E183223-A92-UL-2

Underwriters Laboratories Inc.

Test Record No. 1

This is to correct the resistance of R42 in Critical Components Table only.

MS. SANDY HSU MEAN WELL ENTERPRISES CO LTD 28 WU-CHUAN 3RD RD WUGU INDUSTRIAL PARK Date: 2010/07/09 TAIPEI HSIEN Subscriber: 710861002 248 TAIWAN PartySite: 156523 File No: E183223 Project No: 10CA31920 PD No: 10O27969 Type: R PO Number: 99-0541

Subject: Procedure And/Or Report Material

The following material resulting from the investigation under the above numbers is enclosed.

Issue Date Vol Sec Pages Revised Date 2010/05/19 X2 A92 Revised Proc/Rpt Section 2008/07/03 X2 A97 Revised Proc/Rpt Section

Job Revised date 2010-07-09

Please file revised pages and illustrations in place of material of like identity. New material should be filed in its proper numerical order.

NOTE: Follow-Up Service Procedure revisions DO NOT include Cover Pages, Test Records and Conclusion Pages. Report revisions DO NOT include Authorization Pages, Indices, Section General Pages and Appendixes.

Please review this material and report any inaccuracies to

This material is provided on behalf of Underwriters Laboratories Inc.(UL) or any authorized licensee of UL.

TRT File

Issue Date: 2010-05-19 Page 1 of 14 Report Reference # E183223-A92-UL 2010-07-09

Copyright © 2010

UL TEST REPORT AND PROCEDURE Standard: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology

Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03 (Information Technology Equipment - Safety - Part 1: General Requirements)

Certification Type: Power Supplies for Information Technology Equipment Including Electrical Business Equipment

CCN: QQGQ, QQGQ7 Product: Switching Adapter Model: GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18,

GS40A24, GS40A48 GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48

Rating: Input: Models GS40Ay: 100-240 Vac, 50/60 Hz, 1.0 A Models GS60Ay: 100-240 Vac, 50/60 Hz, 1.4 A Output: Model GS40A05: 5 Vdc, 5.0 A max., 25 W max. Model GS40A07: 7.5 Vdc, 5.34 A max., 40 W max. Model GS40A09: 9 Vdc, 4.45 A max., 40 W max. Model GS40A12: 12 Vdc, 3.34 A max., 40 W max. Model GS40A15: 15 Vdc, 2.67 A max., 40 W max. Model GS60A18: 18 Vdc, 2.22 A max., 40 W max. Model GS40A24: 24 Vdc, 1.67 A max., 40 W max. Model GS40A48: 48 Vdc, 0.84 A max., 40 W max. Model GS60A05: 5 Vdc, 6.0 A max., 30 W max. Model GS60A07: 7.5 Vdc, 6.0 A max., 45 W max. Model GS60A09: 9 Vdc, 6.0 A max., 54 W max. Model GS60A12: 12 Vdc, 5.0 A max., 60 W max. Model GS60A15: 15 Vdc, 4.0 A max., 60 W max. Model GS60A18: 18 Vdc, 3.33 A max., 60 W max. Model GS60A24: 24 Vdc, 2.5 A max., 60 W max. Model GS60A48: 48 Vdc, 1.25 A max., 60 W max.

Applicant Name and Address: MEAN WELL ENTERPRISES CO LTD

28 WU-CHUAN 3RD RD WUGU INDUSTRIAL PARK TAIPEI HSIEN 248 TAIWAN

Issue Date: 2010-05-19 Page 2 of 14 Report Reference # E183223-A92-UL 2010-07-09

Copyright © 2010

This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL.

Ethan Huang Prepared by: Underwriters Laboratories Inc.

Sam Fu Reviewed by: Underwriters Laboratories Inc.

Issue Date: 2010-05-19 Page 3 of 14 Report Reference # E183223-A92-UL 2010-07-09

Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions - i. Part AC details important information which may be applicable to products covered by this Procedure.

Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report.

ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report.

iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.

Product Description This product is a cord connected type power unit intended to be used for information technology equipment in TN power systems and are for indoor use only. It consists of an isolated transformer with electronic circuitry housed in a thermoplastic enclosure. It is also provided with appliance inlet for input connection and a length of cord terminated with a molded-on non-standard polarized output connector for output connection. Model Differences Models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48 are identical to each other except for output rating and secondary winding of transformer. Models GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 are identical to each other except for output rating and secondary winding of transformer. Models GS40Ay and GS60Ay are identical except for transformer. Technical Considerations

Equipment mobility : movable

Connection to the mains : pluggable A

Operating condition : continuous

Over voltage category : OVC II

Mains supply tolerance (%) : +10%, -10%

Tested for IT power systems : No

IT testing, phase-phase voltage (V) : N/A

Class of equipment : Class I (earthed)

Issue Date: 2010-05-19 Page 4 of 14 Report Reference # E183223-A92-UL 2010-07-09

Mass of equipment (kg) : < 18

Pollution degree : PD 2

IP protection class : IP X0

The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer’s specification of: 40°C

The means of connection to the mains supply is: Pluggable A, Detachable power cord

The product is intended for use on the following power systems: TN

The equipment disconnect device is considered to be: Appliance inlet

The following accessible locations (with circuit/schematic designation) are within a limited current circuit: Vout (+ to -)

The following circuit locations (with circuit/schematic designation) were investigated as a limited power source (LPS): Vout (+ to -)

Additional Information E183223-A92-UL, Revision: Alternate plastic material of enclosure, Sabic Plastic, Model 945. Markings and instructions Clause Title Marking or Instruction Details Power rating - Ratings

Ratings (voltage, frequency/dc, current)

Power rating - Model

Model Number

Power rating - Company identification

Listee's or Recognized company's name, Trade Name, Trademark or File Number

Fuses - Rating Rated current and voltage and type located on or adjacent to fuse or fuseholder.

Fuses - Non-operator access/soldered-in fuses

Unambiguous reference to service documentation for instructions for replacement of fuses replaceable only by service personnel

Issue Date: 2010-05-19 Page 5 of 14 Report Reference # E183223-A92-UL 2010-07-09

LPS Marking "Optionally marked with "LPS" or "Limited Power Source" on the unit."

Special Instructions to UL Representative N/A Production-Line Testing Requirements Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for further information.

Model Component Removable

Parts Test probe location V

rms V dc Test Time,

s N/A --- --- --- --- --- ---

Earthing Continuity Test Exemptions - This test is not required for the following models: N/A Electric Strength Test Exemptions - This test is not required for the following models: N/A Electric Strength Test Component Exemptions - The following solid-state components may disconnected from the remainder of the circuitry during the performance of this test: N/A Sample and Test Specifics for Follow-Up Tests at UL

Model Component Material Test Sample(s) Test

Specifics N/A --- --- --- --- ---

Issue Date: 2010-05-19 Page 6 of 14 Report Reference # E183223-A92-UL 2010-07-09

TABLE: List of Critical Components

Object/part No. Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

Enclosure Sabic Innovative Plastics Japan L L C

940(f1) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL

Enclosure (Alternate) Sabic Innovative Plastics US L L C

945(GG) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL

Enclosure (Alternate) Sabic Innovative Plastics Japan L L C

945(GG) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL

Enclosure (Alternate) Sabic Innovative Plastics B V

945(GG) V-0, 120 degree C, minimum 1.8 mm thick. Measured overall 125 by 50 by 31.5 mm. Two halves construction, secured together by screws.

QMFZ2 UL

Appliance Inlet Various Various Rated minimum 10 A, 250 Vac. Rated minimum 70 degree C. Grounded type, ground terminal directly soldered to earth trace on PWB.

AXUT2, AXUT8 UL

Output Cord Various Various Maximum 3.05 m, marked VW-1 or FT-1, terminates with a polarized connector outside enclosure.

AVLV2, AVLV8 UL

Output Cord Strain Relief

Various Various PVC bushing integrally molded on output cord. Provided when Output Cord provided.

QMFZ2 UL

Insulating Tubing/Sleeving

Various Various FEP, PTFE, PVC, TFE, neoprene, or marked VW-1; 105 degree C, 300 V, min. 0.4 mm thick. See Table 2.10.3, Supplementary Info, for safety relevant locations.

UZFT2, UDPU2, YDTU2

UL

Printed Wiring Board Various Various Rated minimum V-1, minimum 130 degree C. See Table 2.10.3, Supplementary Info, for safety relevant locations.

ZPMV2 UL

Fuse (FS1) Various Various T2 A, 250 Vac. JDYX, JDYX7 UL Fuse (FS1) (Alternate) Conquer Electronics

Co., Ltd. MST T2 A, 250 Vac. JDYX2, JDYX8 UL

Thermistor (RTH1) (Optional)

Various Various NTC, rated minimum 3 A, maximum 20 ohms, at 25 degree C.

-- --

Line Choke (LF1) (Optional)

Various TR-732 Open type construction. Rated minimum 130 degree C.

-- --

Issue Date: 2010-05-19 Page 7 of 14 Report Reference # E183223-A92-UL 2010-07-09

Object/part No. Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

Core (LF1) Various Various Ferrite, toroidal, measured overall 9 mm OD by 5 mm ID by 3 mm wide.

-- --

Coil (LF1) Various Various Rated minimum 130 degree C. OBMW2 UL Triple Insulated Winding Wire (LF1)

Various Various Rated minimum 130 degree C. OBJT2 UL

X-Capacitor (C1) (Optional)

ARCOTRONICS SPA

R.46 Rated maximum 0.47 µF, minimum 250 Vac, 110 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional)(Alternate)

ARCOTRONICS SPA

R.49 Rated maximum 0.47 uF, minimum 250 Vac, 110 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

EPCOS ELECTRONIC COMPONENTS S A

B3292 series Rated maximum 0.47 uF, minimum 250 Vac, 105 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

ISKRA KONDENZATORJI D D

KNB1530 Rated maximum 0.47 uF minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

ISKRA KONDENZATORJI D D

KNB1560 Rated maximum 0.47 uF, minimum 250 Vac, 125 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

LIOW GU ELECTRONICS INDUSTRY CO LTD

GS-L Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

PILKOR ELECTRONICS CO LTD

PCX2 335M Rated maximum 0.47 uF, minimum 250 Vac, 105 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

PILKOR ELECTRONICS CO LTD

PCX2 337 Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to

FOWX2, FOWX8 UL

Issue Date: 2010-05-19 Page 8 of 14 Report Reference # E183223-A92-UL 2010-07-09

Object/part No. Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

compliance with IEC 60384-14. X-Capacitor (C1) (Optional) (Alternate)

ULTRA TECH XIPHI ENTERPRISE CO LTD

HQX Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

VISHAY CAPACITORS BELGIUM N V

339 Rated maximum 0.47 uF, minimum 250 Vac, 105 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

CHENG TUNG INDUSTRIAL CO LTD

CTX Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

X-Capacitor (C1) (Optional) (Alternate)

SHINY SPACE ENTERPRISE CO LTD

SX1 Rated maximum 0.47 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bleeder Resistors (R1, R2)

Various Various Each rated 1.5 Mohms, minimum 1/4 W. -- --

Line Choke (LF2) (Optional)

Various TR-733 Open type construction. Rated minimum 130 degree C.

-- --

Core (LF2) Various Various Ferrite, toroidal, measured overall 16 mm OD by 10 mm ID by 5 mm wide.

-- --

Coil (LF2) Various Various Rated minimum 130 degree C. OBMW2 UL Y-Capacitor (C30) (Optional)

MURATA MFG CO LTD

KX, KH Rated maximum 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Y-Capacitor (C30) (Optional) (Alternate)

WALSIN TECHNOLOGY CORP

AH, AC Rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Y-Capacitor (C30) (Optional) (Alternate)

TDK-EPC CORP. CD, CS Each rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Issue Date: 2010-05-19 Page 9 of 14 Report Reference # E183223-A92-UL 2010-07-09

Object/part No. Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

Y-Capacitor (C30) (Optional) (Alternate)

WELSON INDUSTRIAL CO LTD

WD, KL Each rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Rectifier (BD1) Various Various Rated minimum 4 A, minimum 500 V. -- -- Electrolytic Capacitor (C5)

Various Various Integral pressure relief, rated maximum 120 µF, minimum 400 V, minimum 105 degree C.

-- --

Transistor (Q1) Various Various Rated minimum 2 A, minimum 500 V. -- -- Bridge Capacitor (C31, C32) (Optional)

MURATA MFG CO LTD

KX Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Capacitor (C31, C32) (Optional) (Alternate)

WALSIN TECHNOLOGY CORP

AH Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Capacitor (C31, C32) (Optional) (Alternate)

TDK-EPC CORP. CD Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Bridge Capacitor (C31, C32) (Optional) (Alternate)

WELSON INDUSTRIAL CO LTD

WD Rated maximum 1000 pF, minimum 250 Vac, 125 degree C. Class Y1. The damp heat test duration in 21 days minimum. Certified to compliance with IEC 60384-14.

FOWX2, FOWX8 UL

Optical Isolator (U2, U3) Sharp Corp., Electronic Components Group

PC123 Minimum 3000 V ac isolation. Double protection. FPQU2, FPQU8 UL

Optical Isolator (U2, U3) (Alternate)

Lite-On Technology Corp.

LTV-817 Minimum 3000 V ac isolation. Double protection. FPQU2, FPQU8 UL

Transformer (T1) (Models GS60Ay)

Long Sail Electronic Co., Ltd.

TF-1738, (for y=05), TF-1739 (for y=07), TF-1740 (for y=09), TF-1741 (for y=12), TF-1742 (for y=15), TF-

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL

Issue Date: 2010-05-19 Page 10 of 14 Report Reference # E183223-A92-UL 2010-07-09

Object/part No. Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

1743 (for y=18), TF-1744 (for y=24), TF-1745 (for y=48)

Transformer (T1) (Models GS60Ay) (Alternate)

Jet Signal Industries Co., Ltd.

TF-1738, (for y=05), TF-1739 (for y=07), TF-1740 (for y=09), TF-1741 (for y=12), TF-1742 (for y=15), TF-1743 (for y=18), TF-1744 (for y=24), TF-1745 (for y=48)

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL

Transformer (T1) (Models GS40Ay)

Long Sail Electronic Co., Ltd.

TF-1782 (for y=05), TF-1783 (for y=07), TF-1784 (for y=09), TF-1785 (for y=12), TF-1786 (for y=15), TF-1787 (for y=18), TF-1788 (for y=24), TF-1789 (for y=48)

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL

Transformer (T1) (Models GS40Ay) (Alternate)

Jet Signal Industries Co., Ltd.

TF-1782 (for y=05), TF-1783 (for y=07), TF-1784 (for y=09), TF-1785 (for y=12), TF-1786 (for y=15), TF-1787 (for y=18), TF-1788 (for y=24), TF-1789 (for y=48)

Class B (130 degree C) Insulation System, Type SBI4.2.

OBJY2 UL

Issue Date: 2010-05-19 Page 11 of 14 Report Reference # E183223-A92-UL 2010-07-09

Object/part No. Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

Core (T1) (Models GS60Ay)

Various Various Ferrite, measured overall 32 by 22.55 by 22 mm. Provided with Insulating tape, on bottom half of Core. Outer core wrapped with insulation tape.

-- --

Core (T1) (Models GS40Ay)

Various Various Ferrite, measured overall 26.5 by 20.15 by 19 mm. Provided with Insulating tape, on bottom half of Core. Outer core wrapped with insulation tape.

-- --

Coil (T1) Various Various Rated minimum 130 degree C. OBMW2 UL Triple Insulated Winding Wire (T1)

Furukawa Electric Co., Ltd.

TEX-E Rated minimum 130 degree C. OBJT2 UL

Triple Insulated Winding Wire (T1) (Alternate)

Totoku Electric Co., Ltd.

TIW-2 Rated minimum 130 degree C. OBJT2 UL

Triple Insulated Winding Wire (T1) (Alternate)

Totoku Electric Co., Ltd.

TIW-3 Rated minimum 155 degree C. OBJT2 UL

Bobbin (T1) Sumitomo Bakelite Co., Ltd.

PM-9820, PM-9630

Rated V-0, 150 degree C, minimum 0.51 mm thick. QMFZ2 UL

Insulating Tape (T1) 3M Co. 1350-1, 1350F-1, 1350T-1

Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL

Insulating Tape (T1) (Alternate)

Symbio Inc. 35660, 35660Y Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL

Insulating Tape (T1) (Alternate)

Bondtec Pacific Co., Ltd.

370S Polyester tape, 0.05 mm thick, rated 130 degree C. Provided between windings and provided around primary windings minimum 3.5 mm from bottom bobbin edge.

OANZ2 UL

Varnish (T1) Hitachi Chemical Co., Ltd.

WP-2952F-2G Rated minimum 130 degree C. OBOR2 UL

Varnish (T1) (Alternate) John C Dolph Co. BC-346A Rated minimum 130 degree C. OBOR2 UL Varnish (T1) (Alternate) Elantas Electrical

Insulation Elantas PDG Inc.

468-2-7++ Rated minimum 130 degree C. OBOR2 UL

Tubing (T1) Great Holding Industrial Co., Ltd.

TFT, TFL Rated minimum 200 degree C. Provided on all exit leads.

YDPU2 UL

Tubing (T1) (Alternate) Zeus Industrial TFE-TW-300 Rated minimum 200 degree C. Provided on all exit YDPU2 UL

Issue Date: 2010-05-19 Page 12 of 14 Report Reference # E183223-A92-UL 2010-07-09

Object/part No. Manufacturer/ trademark

type/model technical data CCN Marks of Conformity

Products Inc. leads. Heat Sink (HS1) Various Various Aluminum, minimum 1 mm thick. Provided with

insulation tape near secondary parts. See Enclosure for detailed dimensions.

-- --

Heat Sink (HS2) Various Various Aluminum, minimum 1.5 mm thick. Provided with insulation tape near primary parts. See Enclosure for detailed dimensions.

-- --

Insulation Tape (HS1, HS2)

Various Various Polyester tape, 0.05 mm thick, rated 130 degree C. See Enclosure for locations of tapes.

OANZ2 UL

LED Various Various Located in SELV circuit. -- -- Resistor (R42) (For Model GS40A05)

Various Various Rated minimum 0.91 ohms, minimum 2W. -- --

Resistor (R42) (For models GS40A07, GS40A12, GS40A15, GS40A24,GS40A48)

Various Various Rated minimum 0.62 ohm , minimum 2W -- --

Resistor (R42) (For model GS40A09)

Various Various Rated minimum 0.6 ohm , minimum 2W -- --

Resistor (R42) (For model GS40A18)

Various Various Rated minimum 0.68 ohm , minimum 2W -- --

Resistor (R42) (For model GS60A05)

Various Various Rated minimum 0.91 ohm , minimum 2W -- --

Resistor (R42) (For model GS60A07)

Various Various Rated minimum 0.6 ohm , minimum 2W -- --

Resistor (R42) (For model GS60A09)

Various Various Rated minimum 0.47ohm , minimum 2W -- --

Resistor (R42) (For models GS60A12, GS60A15, GS60A18, GS60A24)

Various Various Rated minimum 0.5 ohm , minimum 2W -- --

Resistor (R42) (For model GS60A48)

Various Various Rated minimum 0.56 ohm , minimum 2W -- --

Adhesive Glue Various Various Rated minimum V-2, 105 degree C. QMFZ2 UL Label Various Various Rated minimum 80 degree C. PGDQ2 UL

Issue Date: 2010-05-19 Page 13 of 14 Report Reference # E183223-A92-UL 2010-07-09

Issue Date: 2010-05-19 Page 14 of 14 Report Reference # E183223-A92-UL 2010-07-09

Enclosures

Type Supplement Id Description Photographs 3-01 Enclosure - Front View Photographs 3-02 Enclosure - Rear View Photographs 3-03 Internal - Top View Photographs 3-04 PWB - Component View Photographs 3-05 PWB - Trace View

Diagrams 4-01 Line Choke (LF1) Diagrams 4-02 Line Choke (LF2) Diagrams 4-03 Transformer (T1) (GS60Ay models) (Long Sail) Diagrams 4-04 Transformer (T1) (GS60Ay models) (Jet Signal) Diagrams 4-05 Transformer (T1) (GS40Ay models) (Long Sail) Diagrams 4-06 Transformer (T1) (GS40Ay models) (Jet Signal) Diagrams 4-07 Heat Sink (HS1) Diagrams 4-08 Heat Sink (HS2) Diagrams 4-09 Insulation Tape (HS1, HS2) Diagrams 4-10 Strain Relief Diagrams 4-11 Top Enclosure Drawing Diagrams 4-12 Bottom Enclosure Drawing

Schematics + PWB 5-01 Circuit Schematic (GS60Ay models) Schematics + PWB 5-02 Circuit Schematic (GS40Ay models) Schematics + PWB 5-03 PWB Layout (All models)

Manuals Miscellaneous

File E183223 Vol. X2 Sec. A92 PHO-01 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-02 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-03 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-04 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 PHO-05 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-01(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-01(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-01(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-02(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-02(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-02(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-03(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 12)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 13)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 14)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 15)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 16)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 17)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 18)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 19)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-04(Page 20)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-05(Page 12)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 5)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 6)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 7)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 8)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 9)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 10)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 11)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 12)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 13)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 14)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 15)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 16)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 17)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 18)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 19)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-06(Page 20)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-07 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-08 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-09 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-10 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-11 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 DIA-12 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-01 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-02 Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 1)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 2)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 3)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 4)Issued: 2010-05-19

File E183223 Vol. X2 Sec. A92 SCH-03(Page 5)Issued: 2010-05-19

Issue Date: 2010-05-19 Page 1 of 2 Report Reference # E183223-A92-ULRevision Date: 2010-07-09 Test Record

Test Record No. 1

This is to correct the resistance of R42 in Critical Components Table only.

Issue Date: 2010-05-19 Page 2 of 2 Report Reference # E183223-A92-ULRevision Date: 2010-07-09 Test Record

Test Record No. 2

--The manufacturer submitted representative production sample of Switching Adaptor, Models:GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48,GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 employing the alternate plastic material of enclosure, Sabic Plastic, model 945.--All tests were conducted by PSE Inc. Taiwan located at San Chung City, Taipei, Taiwan under theTPTDP program.--Only the tests checked in “List of Tests” pages were deemed necessary.--Unless otherwise indicated, all tests were conducted on Models GS60A12.--Tests performed on Model GS60A12 were considered to be representative of models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48,GS60A05, GS60A07, GS60A09, GS60A15, GS60A18, GS60A24, GS60A48.--Only limited tests were performed on Models GS40A05, GS40A07, GS40A09, GS40A12, GS40A15, GS60A18, GS40A24, GS40A48,GS60A05, GS60A07, GS60A09, GS60A12, GS60A15, GS60A18, GS60A24, GS60A48 employing alternate plastic material of enclosure, Sabic Plastic, model 945 due to testing previously performed on the subject unit.--Test results reported related only to the items tested.

The following tests were conducted: Test Testing Location/Comments End Product Reference Page General Guidelines Power Supply Reference Page Strain Relief (3.2.6, 4.2.1, 4.2.7) Steady Force (4.2.1 - 4.2.4) Impact (4.2.5, 4.2.1, Part 22 10.2) Drop (4.2.6, 4.2.1) Stress Relief (4.2.7, 4.2.1) Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this Test Report.

The following supplements are provided as a part of this Test Record. NOTE: These supplements are only available to the Applicant via the CDA system.

Type Supplement Id Description Attachment 2-04 CRD Datasheet 2-05 Datasheet


Recommended