Date post: | 23-Apr-2023 |
Category: |
Documents |
Upload: | khangminh22 |
View: | 0 times |
Download: | 0 times |
Design and Install for you
The total or partial reproduction of this catalogue without the express authorisation of Kaysun UK is prohibited.
Design and Install for youGENERAL CONTENTS
GENERAL CONTENTS
TWINS ...................................................................................................... 118SUPERSLIM CASSETTE .......................................................................... 119
CEILING / FLOOR .................................................................................... 119
DUCTS ...................................................................................................... 119
HIGH-CAPACITY ZEN COMMERCIAL RANGEINTRODUCTION TO THE RANGE ..................................................................122
HIGH-CAPACITY SETS OF DUCTS .............................................................123
AIR-COOLED ............................................................................................124
WATER-COOLED .................................................................................... 128
STATIC PRESSURE GRAPHS ................................................................. 130
VRF INDUSTRIAL AMAZON RANGEINTRODUCTION TO THE PRODUCT RANGE ... ...........................................134INDOOR UNITS ............................................... .......................................141
WALL ..................................................................... .KAYF.......................143
DOUBLE FLOW CONSOLE .......................................KSDF......................145
FLOOR STANDING EXPOSED/CONCEALED...........KS(E)F.....................147
CEILING / FLOOR ....................................................KPCF.......................149
ONE WAY CASSETTE...............................................KCOF.......................151
CASSETTE ART FLUX 360º (600x600)..............KCIF........................153
CASSETTE ART FLUX 360º ....................................KCIBF......................155
DUCTS .......................................................................KPDF......................157
STATIC PRESSURE GRAPHS........................................................... 161
HIGH PRESSURE DUCTS ........................................KPDHF....................165
KAHU ....................................................................... KAHU.....................169
DOMESTIC HOT WATER RECOVERY KIT ................ KWF.......................171
OUTDOOR UNITS ........................................................ ..............................1742 PIPES .......................................................... .........................................176
MINI AMAZON VRF
SINGLE PHASE ..................................................KMF DVN...............178
THREE-PHASE.....................................................KMF DTN2............ 180
AMAZON UNITARIO SIDE AIR DISCHARGE...........KMF........................182
AMAZON UNITARIO TOP AIR DISCHARGE...........K2UF.......................184
AMAZON IV PRO .................................................... K2FDN4S................186
AMAZON III W ........................................................K2F DN3W..............188
3 PIPES ......................................................................................................... 190
AMAZON III PRO .....................................................K3F DN3S...............192
KVB BOXES....... .............................................. KVB.........................194
SIZING ........................................................... ......................................... 196DISTANCES AND HEIGHT DIFFERENCES ...... .......................................... 202
CONTROLS CONTROL SYSTEM RANGEINTRODUCTION TO THE RANGE ..............................................................210
UNITSWIRELESS SINGLE AND WIRED CONTROLLERS................................212
CENTRALISED.........................................................................................214
BMS & SOFTWARE.................................................................................216
ACCESSORIES.........................................................................................224
SUITE RESIDENTIAL PRODUCT RANGESUITE 1X1 ...................................................................................................22
INTRODUCTION TO THE PRODUCT RANGE.........................................22SETS ....................................................................................................26
PRODIGY ............................................................................................ 28
AUREA II R-410A .............................................................................. 30
AUREA II R-32 .................................................................................. 32
ONNIX ............................................................................................... 34
DOUBLE FLOW CONSOLE ................................................................ 36
MULTISYSTEM SUITE .................................................................................38INTRODUCTION TO THE PRODUCT RANGE.........................................38R-410A MULTISYSTEM RANGE .......................................................... 40
PRODIGY ............................................................................................ 42
AUREA II R-410A ............................................................................. 44
ONNIX ................................................................................................ 46
DOUBLE FLOW CONSOLE ................................................................48
CASSETTE ........................................................................................ 50
DUCT ................................................................................................. 52
STATIC PRESSURE GRAPHS .................................................... 54
OUTDOOR UNITS .............................................................................. 56
COMBINATION TABLES ................................................................... 58
R-32 MULTISYSTEM RANGE .............................................................. 68AUREA II R-32 ................................................................................... 68
OUTDOOR UNITS .............................................................................. 70
COMBINATION TABLES ....................................................................72
ZEN AXIAL COMMERCIAL RANGEINTRODUCTION TO THE RANGE ................................................................78SETS .......................................................................................................... 80
CASSETTE (600X600) ............................................................................. 82
SUPERSLIM CASSETTE ..........................................................................84
CEILING / FLOOR .....................................................................................88
DUCTS ...................................................................................................... 92
STATIC PRESSURE GRAPHS............................................................ 96
TWINS ......................................................................................................100CASSETTE (600X600) .............................................................................101
SUPERSLIM CASSETTE ..........................................................................101
DUCTS .....................................................................................................102
CEILING / FLOOR ....................................................................................103
ZEN CENTRIFUGAL COMMERCIAL RANGEINTRODUCTION TO THE RANGE .............................................................. 106SETS .........................................................................................................108
SUPERSLIM CASSETTE .......................................................................... 110
CEILING / FLOOR .....................................................................................112
DUCTS .......................................................................................................114
STATIC PRESSURE GRAPHS............................................................116
NEXUS CHILLERS RANGEINTRODUCTION TO THE RANGE ..............................................................228CHILLERS .................................................................................................232MINICHILLERS ...............................................................KEM D(V)(T)N........234
MODULAR FULL DC INVERTER CHILLERS ................ KEM DNS3..............236
DIGITAL SCROLL MODULAR CHILLERS .....................KEM DHN3..............238
EXTERNAL HYDRAULIC KITS ..................................... .KH ..........................240
FIXED SCROLL MODULAR CHILLERS ......................... KEM HN3................242
SCREW CHILLERS ........................................................ KEX - A (W)............244
CENTRIFUGAL CHILLERS ............................................................................248
WATER TERMINAL UNITS PRODUCT RANGE FAN COILSINTRODUCTION TO THE RANGE ..............................................................252UNITS
WALL .................................................................. KFC-AY....................255
CEILING / FLOOR ................................................ KFC-S(E)..................257
CASSETTES 600x600 ........................................ KFC-CI ..................... 259
CASSETTES ........................................................ KFC-CIS....................261
DUCTS ................................................................. KFC-PD....................263
HIGH-PRESSURE DUCTS ................................... KFC-PDH..................265
AQUATIX DOMESTIC HOT WATER RANGEINTRODUCTION TO THE PRODUCT RANGE.............................................269UNITS
AQUANTIA ............................................................ MONOBLOC.............277
AQUANTIA ............................................................ SPLIT.......................281
DOMESTIC HOT WATER DEPOSITS .................... BS, G........................285
SWIMMING POOLS .............................................. KSWP......................289
COMPAK ................................................................ KHP ACS..................291
Spare PartsKAYSUN also has a spare parts business, the aim of which is to provide the best possible service with delivery within 24h and specialist advice and service for each product over the phone, so as to protect the prestige and excellence of the products represented.
After-sales serviceTo ensure the quality of service at all stages of its value chain, KAYSUN has a highly specialised after-sales service area to foster the agile and effective resolution of any issues that may
arise.
KAYSUN spare parts• 30,000 parts in stock.
• + 200 shipments daily.
KAYSUN after-sales service• ISO 9001 and ISO 14001
• Uninterrupted service all year round (24/7 in the transport unit).
The manufacturer of one in every five air conditioning units worldwide
HVAC systemsKAYSUN UK has an alliance with Midea, a world leader in air treatment equipment, to offer integrated climate control projects suitable for all types of installations, from the residential range to the industrial range. KAYSUN is also present in leading projects worldwide, with which it has experienced
rapid expansion.
Great versatility of equipment and advanced technological innovation.
6
Design and Install for you
Go back to General Contents (Index)
OUR ORIGINS
“A well-established Team”
Kaysun is a brand that covers air conditioning and thermal solar energy solutions. Kaysun has a successful and well-known background thanks to over ten years of experience. The company provides air conditioning solutions for both domestic and commercial use, with excellent case studies, including the Barcelona Hilton Hotel. Kaysun has an outstanding presence and international profile, with distributors in France, Morocco, Ireland, Italy, Andorra and Portugal. We are now pleased to bring the product set to the UK.
Kaysun is distributed in the UK by Monodraught Ltd. We are the innovators in our field and for over 40 years have consistently been at the forefront of designing, manufacturing and installing natural ventilation, lighting and cooling products. Our objective is to provide architects, consultants, contractors and building owners with high quality, low maintenance solutions. We deliver the whole Kaysun solution using our in-house team of quotations specialists, IES modellers, controls experts, commissioning and installation engineers. This ensures that we are able to implement our solutions in a fully supported, quality guaranteed environment.
EuropeFrance
England
Ireland
Italy
Portugal
Spain
Andorra
Belgium
The Netherlands
Luxembourg
Slovenia
Malta
Romania
7 Go back to General Contents (Index)
8910
COMMITTED TO THE ENVIRONMENT
Our equipment is manufactured almost entirely from recyclable materials. We have reduced consumption
as far as possible in STANDBY mode and have
improved the energy efficiency of units working at full
capacity, resulting in energy savings for facilities.
1 6
7234
5
“Ten reasons why we stand out”
THE KAYSUN UK GUARANTEE
KAYSUN UK is known for its premium products and
its broad experience in excellent after-sales services.
KAYSUN UK, the company's own brand, was developed
with the standards for quality and technological
innovation that have always set us apart.
MAXIMUM RELIABILITY OF OUR EQUIPMENT
We guarantee that our units will have a long service
life, thanks to top-quality materials. This ensure that
the need to make use of their warranties is reduced
to a minimum.
ISO 9001 / ISO 14001
The quality of our products and environment benefits
are two key pillars for KAYSUN. We are proud to have
achieved ISO 9001 and ISO 14001, under the seal of
Frigicoll.
WIDE RANGE
We offer comprehensive solutions for any facility thanks
to the diversity of our product ranges. From residential
split systems to the most complex water terminal units,
and including air curtains, recovery systems, VRFs, chillers,
solar and domestic hot water units.
COMPREHENSIVE PROJECTS
Our team of expert technicians carries out HVCA and
ventilation comprehensive specific projects for every
single customer, which allows our company to be able
to adapt to any space and need. A personalised advice
complements this service, thus ensuring the correct
performance of our installation works.
CUTTING-EDGE TECHNOLOGY
Our forward-looking approach goes hand-in-hand
with the incorporation of the latest technology in all
of our equipment. We include features that improve
everything from energy consumption to practicality
and comfort, as in the case of the built-in motorised panel used in the cassettes.
SMART CONTROL
Our smart control devices, allow us to offer comfort
and well-being in any facility. The K01-WIFI device is
the first smart solution for our units, providing the
option of programming and managing air conditioning
units inside and outside your home.
EXCELLENT AFTER-SALES SERVICE
We work to solve all incidents as quickly as possible, leaving our customers completely satisfied with
our after-sales service. We have a team of expert
professionals working for you.
DESIGN AND INSTALL
Our team in the UK are proud to take you project and
provide a design to fit your requirements. We manage
the whole process through to installation and beyond.
ISO
8
Design and Install for you
Go back to General Contents (Index)
Icons for the 2017 catalogue.
Green colour, which stands for ecological innovation, is hard to miss in our 2017 catalogue, showing the energy efficiency of each of our products.
EUROPEAN DIRECTIVE ErP
ECODESIGN DIRECTIVE
On January 1st, 2013 the "ecodesign" directive took effect,
which in order to reduce energy consumption and benefit
the environment, requires the adoption of legal measures
to establish requirements for energy labelling and supplying
energy-related information about products.
The Commission adopted Regulation 626/2011, introducing
the new energy labels which are mandatory for air conditioning
units connected to the grid with a nominal refrigerating power
(or nominal heating power, if the unit only runs as a heat pump) of less than 12kW.
These labels contain seasonal energy performance levels, which are based on different outdoor temperatures and part-
load efficiencies to calculate a level of annual consumption in
extremely close detail, thus demonstrating in the most apparent
manner possible the advantages of the Inverter technology used by KAYSUN UK. The sound level rating of the unit is also
displayed.
It is important to make the distinction between SEER and SCOP, where “S” stands for “Seasonal” to indicate the seasonal
variation of annual energy consumption, which is usually
measured according to the hours a unit runs in different climatic
zones over a year.
EUROPEAN DIRECTIVE ErP
CLASSES* SEER SCOP
A+ + + SEER ≥ 8.50 SCOP ≥ 5.10
A+ + 6.10 ≤ SEER < 8.50 4.60 ≤ SCOP < 5.10
A+ 5.60 ≤ SEER < 6.10 4.00 ≤ SCOP < 4.60
A 5.10 ≤ SEER < 5.60 3.40 ≤ SCOP < 4.00
B 4.60 ≤ SEER < 5.10 3.10 ≤ SCOP < 3.40
C 4.10 ≤ SEER < 4.60 2.80 ≤ SCOP < 3.10
D 3.60 ≤ SEER < 4.10 2.50 ≤ SCOP < 2.80
ENERGY EFFICIENCY CLASSES for air conditioners
Minimum energy efficiency values have been established for both
cooling and heating mode for all products for sale after January
2013 to which that regulation applies. Inefficient products will not
be able to be sold on the European market, since they do not meet
the requirements of the mentioned regulation.
(*) with the exception of dual and single duct units.
KAYSUN UK offer a complete design and install for you solution. Our credentials in the sustainable building industry
mean that we are proud to present a 2017 catalogue in
which all products meet the requirements of the new energy
regulations in force. SCOPErP SEER
9 Go back to General Contents (Index)
ENERGY LABELS
The label makes a distinction between
climatic areas, and therefore offers users
more detailed information and a more
accurate idea of the efficiency of the units
according to the climatic area in which they
are located.
In addition to the Ecodesign directive,
there is another directive hat that affects
KAYSUN. All units with fans with a motor
that consumes between 125W and 500 kW
of energy meet certain minimum energy
efficiency requirements.
SEER and SCOP. These values indicate
the Seasonal Energy Efficiency Ratio for
refrigerating (SEER) and heating (SCOP)
calculated based on annual hours of use
in different climatic zones.
ENERGY CLASS For heating and cooling,
labels will increase up to Class A+++.
SOUND LEVELS The sound level of indoor
and outdoor units, expressed in decibels.
CLIMATIC ZONES The map below shows
the three climatic zones that have been
established for a better evaluation:
Average (*) Annual temperature of
Strasbourg.
Hot Annual temperature of Athens.
Cold Annual temperature of Helsinki.
NOMINAL POWER ACOUSTIC POWER IN dB(A)
≤ 6kW
Indoor 60
Outdoor 65
≤ 12kW
Indoor 65
Outdoor 70
MINIMUM ENERGY EFFICIENCY REQUIREMENTS
MINIMUM ENERGY EFFICIENCY REQUIREMENTS 2015NOMINAL POWER
GWP OF THE REFRIGERANT AIR CONDITIONERS DUAL DUCT SINGLE DUCT
SEER SCOP EER Cop EER Cop
< 6KWIf the GWP > 150 4.60 3.80 2.60 2.60 2.60 2.04
If the GWP < 150 4.14 3.42 2.34 2.34 2.34 1.84
6 - 12 KWIf the GWP > 150 4.30 3.80 2.60 2.60 2.60 2.04
If the GWP < 150 3.87 3.42 2.34 2.34 2.34 1.84
We would like to note that there are also restrictions regarding sound levels, and therefore KAYSUN UK offers efficient and
environmentally friendly products that provide comfort and a quality lifestyle to end users.
(*) It is only mandatory to express the SCOP for the
average climate zone.
11 Go back to General Contents (Index)
2.0 2.6 2.8 3.5 4.2 4.8 5.2 6.2 7.1 7.8 8.0 10.5 12.0 14.0 16.0 kW pag.
SU
ITE
1X
1
PRODIGY 30
AUREA II R-410A 32
AUREA II R-32 34
ONNIX 36
CONSOLE 40
MU
LTIS
YS
TEM
R-4
10A
PRODIGY 44
AUREA II 46
ONNIX 48
CONSOLE 50
CASSETTE 52
DUCTS 54
OUTDOOR 58
R-3
2
AUREA II 70
OUTDOOR 72
SUITE RESIDENTIAL PRODUCT RANGE
2x
2x
2x
3x
3x
3x
4x
4x
5x
5x
NEW
NEW
NEW
NEW
NEW
12
Design and Install for you
Go back to General Contents (Index)
OUR PRODUCT RANGE
ZEN COMMERCIAL RANGE
2.6 3.5 5.2 7.1 9.0 10.5 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 56.0 kW pag.
AX
IAL
1X1
SY
STE
MS
600x600 CASSETTE 84
SUPERSLIM CASSETTE 86
FLOOR-CEILING 90
DUCTS 94
TWIN
S
600x600
CASSETTE103
SUPERSLIM CASSETTE 103
FLOOR-CEILING 104
DUCTS 105
CEN
TRIF
UG
AL
1X1
SY
STE
MS
SUPERSLIM CASSETTE 112
FLOOR-CEILING 114
DUCTS 116
TWIN
S
SUPERSLIM CASSETTE 121
FLOOR-CEILING 121
DUCTS 121
HIG
H C
APA
CITY
AIR
CO
ND
ENSE
D
FRONT AIR DISCHARGE
126128
VERTICAL AIR DISCHARGE
126128
WA
TER
CO
ND
ENSE
D
130
13 Go back to General Contents (Index)
SUITE ZEN AMAZON
PRODIGY AUREA II ONNIX CONSOLE MULTI pag.
WIR
ELE
SS KID-02 S 216
KI-02.3 S 216
IND
IVID
UA
L W
IRED
KC-01 S
except for Aurea, Onnix and Cassette 840x840 models
except cassette
840x840216
KC-03 SPS
ducts and columns only 217
KC-02.1 H
except for Aurea, Onnix and Cassette 840x840 models
except cassette
840x840217
KCT-02.1 SR
except for Aurea, Onnix and Cassette 840x840 models
217
CEN
TRA
LISE
D C
ON
TRO
LS
KMC-32 E 218
KCC-64 I-PS
except wall-mounted 218
KCC-64 I PS
except wall-mounted 218
KCC-16
except wall-mounted 219
KCC-64 WEB
except wall-mounted 219
INTE
GRA
TED
CO
NTR
OLS
K01-LON
except wall-mounted 220
K01-BACNET
except wall-mounted 222
K02-MODBUS
except wall-mounted
221
K03-MODBUS
ducts and columns only
221
KAYNET CONTROL
except wall-mounted
226
K01-KNX
except wall-mounted 223
K01 WIFI 224
ACC
ESSO
RIE
S
K01-WATT
except for Mini-Amazon II
229
KAHU
except for Mini-Amazon II and
Amazon III 3 pipes
228
INTERFACE XYE ON
Only KSD
229
CONTROLS CONTROL SYSTEM RANGE
NEW
NEW
14
Design and Install for you
Go back to General Contents (Index)
OUR PRODUCT RANGE
1.5 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.0 14.0
IND
OO
R U
NIT
S
WALL-MOUNTED
DOUBLE FLOW CONSOLE
FLOOR STANDING EXPOSED/
CONCEALED
FLOOR / CEILING
CASSETTE 1 VÍA
CASSETTE 600X600
CASSETTE 840X840
DUCTS
HIGH PRESSURE DUCTS
AIR CONDITIONING RECOVERY KIT
KAHU
OU
TDO
OR
UN
ITS
2 P
IPE
S
MINI-AMAZONSINGLE-PHASE
MINI-AMAZONTHREE-PHASE
AMAZON SINGLE FRONT AIR
DISCHARGE
AMAZON SINGLE VERTICAL AIR
DISCHARGE
AMAZON IV PRO
AMAZON III W
3 D
UCT
S
AMAZON III PRO
AMAZON INDUSTRIAL VRF RANGE
NEW
NEW
15 Go back to General Contents (Index)
16.0 18.0 20.0 22.4 25.0 25.2 26.0 28.0 33.5 40.0 45.0 50.0 56.0 61.5 67.0 73.0 75.0 kW Pag.
146
148
150
152
154
156
158
160
168
174
172
182
184
186
188
190
192
196
16
Design and Install for you
Go back to General Contents (Index)
FANCOILS WATER TERMINAL UNITS PRODUCT RANGE
425 510 680 850 1020 1250 1360 1530 1600 1700 2000 2380 2550 3060 3740 m3/h pag.
IND
OO
R U
NIT
S
WALL-
MOUNTED
2 PIPES260
FLOOR / CEILING
2 PIPES
EXPOSED 262
CONCEALED 262
CASSETTE 600 X 600
2 PIPES 264
4 PIPES 264
OUR PRODUCT RANGE
5 7 10 12 14 16 26 30 35 52 65 71 95 130 160 195 200 225 250 260 315 340
CHIL
LER
S
MINICHILLERSINVERTER
Single-phase
Three-phase
MODULAR FULL DC
INVERTER CHILLERS
Withouthydraulic kit
With hydraulic kit
MODULAR CHILLERS
Digital Scroll
Fixed Scroll
ROTARY SCREW
CHILLERS
Air-water
Water-water
2 3 4 5
CHILLERS CENTRIFUGAL
4x
4x
4x 4x 4x
4x
4x
NEXUS CHILLERS PRODUCT RANGE
17 Go back to General Contents (Index)
380 400 435 440 500 510 520 540 565 600 620 630 640 685 690 720 740 750 760 805 815 900 1000 1100 1200 1385 1620 1780 kW pag.
238
238
240
240
242
246
248
250
6 7 8 9 10 mW
252
425 510 680 850 1020 1250 1360 1530 1600 1700 2000 2380 2550 3060 3740 m3/h pag.
IND
OO
R U
NIT
S
CASSETTE
2 PIPES 266
4 PIPES 266
DUCTS
2 PIPES 268
4 PIPES 268
HIGH PRESSURE
DUCTS 2 PIPES 270
18
Design and Install for you
Go back to General Contents (Index)
OUR RANGES
AQUATIX DOMESTIC HOT WATER RANGE
150 200 250 300 350 L pag.
HE
AT
PU
MP
COMPAK 296
SWIMMING POOLS
4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 15000 16000 17000 18000 W
294
100 200 350 500 750 1000 1250 1500 1750 2000 2225 2500 L pag.
DE
PO
SIT
S DEPOSITS FOR
DOMESTIC HOT WATER
290
4 5 6 7 8 12 14 16 kW pag.
AQ
UA
NTI
A S
ING
LE B
LOC
SINGLE-PHASE 282
THREE-PHASE 282
4 5 6 7 8 12 14 16 kW pag.
AQ
UA
NTI
A S
PLI
T SINGLE-PHASE 286
THREE-PHASE 286
AUTOMATIC ADJUSTMENT OF THE BLADES The unit has the capacity to automatically position the blades at the same angle that they were at when it was shut off the last time.
AUTO SWING The wide angle of rotation of the horizontal and vertical blades guides the cold or hot air, creating a flow capable of reaching any corner of the space.
AIR OUTLET The unit has two air outlets: upper and lower.
AIR OUTLET 360º The indoor unit is capable of spreading a 360º air flow, thus providing high comfort and reaching all corners of the room.
AIR INTAKE The indoor unit has two possible air intakes: the upper and the rear intake.
FRESH AIR SUPPLY “X %” of fresh air directly enters the indoor unit through an orifice.
MULTIPLE AIR INLETS This unit is fitted with four air return inlets: upper inlet, lower inlet, right inlet and left inlet.
R410A ECOLOGICAL REFRIGERANT The ecological refrigerant R410A causes no damage to the ozone layer, helping minimize our impact on the environment.
R134A REFRIGERANT R134A ecological refrigerant.
R-32 REFRIGERANT The unit works with R-32 ecological refrigerant.
DRAINAGE PUMP A system which is capable of removing condensate up to 750 mm.
ADDRESSING The control system allows setting an address for indoor units inside the communication bus.
TWO COMMUNICATION WIRES The system uses two shielded communication wires without polarity.
HERTZ The units can function at 50 or 60 Hz.
TWINS Connection system that allows the two indoor units to be combined with an outdoor unit, making installation easier and more economical.
MOTORIZED PANEL This type of panel descends automatically by up to 4 metres to facilitate the maintenance and cleaning of the filter.
SOLAR PANEL A very efficient set of equipment which exploits the sun's energy using a solar panel.
TECH
NOL
OGY
DIGITAL SCROLL A compressor with digital scroll technology that provides total control over the capacity and power of the system in accordance with the needs of each indoor unit.
3D TECHNOLOGY Triple DC inverter technology that allows a more constant temperature, high energy saving and significant energy efficiency.
HYDRAULIC KIT A complete, built-in hydraulic kit.
SCROLL The unit is fitted with a highly efficient and powerful scroll compressor.
DC INVERTER COMPRESSOR This feature allows to regulate the power of the compressor, providing optimum control and extremely efficient operation.
CONDENSATION CONTROL Allows the system to refrigerate, even with low outdoor temperatures.
DC INVERTER INTERNAL FAN The unit is fitted with a DC Inverter internal fan.
DC INVERTER EXTEERNAL FAN The unit is fitted with a DC Inverter external fan.
SIMULTANEOUS COOLING/HEATING Heat recovery technology which allows cold and heat to be obtained simultaneously within the same system, optimising the user's comfort.
COOLING AND HEATING Our units are equipped with air conditioning and a heat pump.
ROTARY Unit fitted with a rotary heat exchanger to provide a higher air flow.
SCREW COMPRESSOR Unit fitted with a screw compressor suitable for high compression ratio.
MODULAR Can be combined with other units up to power "x", by connecting the inlet and outlet pipes between units.
COMPACTA Advances in design have reduced the size of the indoor and outdoor units without overlooking any technological details.
SUPER SLIM The new Super Slim cassette can be fitted into any space.
SEER Classification of energy efficiency according to seasonal performance for cooling.
SCOP Classification of energy efficiency according to seasonal performance for heating.
SCOP 4.0 The heat pump performance of a set of units exceeds SCOP 4.0.
ERP Unit that complies with the European Parliament and Council of the European Union's Directive which establishes the ecological design requirements applicable to products that use energy.
ENER
GYRE
FRIG
ERAN
T
AIR
DIST
RIBU
TION
DESI
GN
LED DISPLAY The indoor unit displays the information on a digital display panel.
COMPENSATION TEMPERATURE The possibility of compensating for the difference in temperature between the indoor unit's sensor and the real temperature of the room in heating mode.
8ºC HEATING This feature keeps the temperature in the room from dropping below 8ºC by turning on the unit automatically in heat mode until it reaches 17ºC.
REFRIGERANT CONTROL A sensor on the outdoor unit and an alarm on the indoor unit's display alert the user of the detection of a possible refrigerant leak.
AUTOMATIC MODE The indoor unit automatically changes to heating or cooling operating mode based on the temperature selected.
NIGHT MODE A feature of the indoor unit which reduces the sound level during the night for a more comfortable sleep.
EYE DETECTOR A function that automatically turns off the unit when the sensor does not detect movement in the room for 30 minutes. The unit will switch on again when someone enters the room.
FOLLOW ME A feature which changes the operating mode based on the remote controlled temperature sensor with the aim of maintaining maximum comfort.
WEEKLY PROGRAMMER A control feature which schedules when the unit will turn on/shut off according to the day and time during the week.
SELF-CLEANING A feature of the indoor unit which automatically cleans the machine's battery so as to continue providing fresh, purified air every day.
TURBO MODE This feature reaches the selected temperature within a very short time.
SILENCE MODE A function of the indoor unit that reduces sound pressure using the lowest speed of the fans.
ECO MODE A control feature which reduces consumption, offering high energy efficiency thanks to automatic temperature regulation.
STAND BY The "standby mode" feature allows 80% energy saving with only 1W consumption by the LED display.
INTELLIGENT This feature allows changing the operation parameters of the unit and extracting operation data.
SWITCH OFF DISPLAY This feature allows switching off the display of the indoor units, if necessary.
Wi-Fi This unit can be controlled by a Wi-Fi network through a smartphone application.
LOW SOUND LEVEL New technological advances have allowed the level of sound produced by the indoor units to be reduced by up to 20 dB.
MUTE This feature allows permanently cancelling the indoor unit alarm beeper.
COM
FORT
COM
FORT
INST
ALLA
TION
AN
D SE
RVIC
E
DOMESTIC HOT WATER A system that produces domestic hot water and underfloor heating.
TOUCH SENSITIVE KEYS The keys of the remote control are touch sensitive
ICONS DESCRIPTION
21
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
SUITERESIDENTIAL PRODUCT RANGE
SUITE 1X1...............................................................................................22
INTRODUCTION TO THE PRODUCT RANGE ..........................22
SETS ..........................................................................................26
PRODIGY .............................................................................28
AUREA II R-410A ...............................................................30
AUREA II R-32 ...................................................................32
ONNIX ................................................................................34
DOUBLE FLOW CONSOLE .................................................36
MULTISYSTEM SUITE ...........................................................................38
INTRODUCTION TO THE PRODUCT RANGE ..........................38
R-410A MULTISYSTEM RANGE ..............................................40
PRODIGY .............................................................................42
AUREA II R-410A ..............................................................44
ONNIX .................................................................................46
DOUBLE FLOW CONSOLE .................................................48
CASSETTE .........................................................................50
DUCT ..................................................................................52
STATIC PRESSURE GRAPHS ................................54
OUTDOOR UNITS ..............................................................56
COMBINATION TABLES ....................................................58
R-32 MULTISYSTEM RANGE ...................................................68
AUREA II R-32 ....................................................................68
OUTDOOR UNITS ..............................................................70
COMBINATION TABLES ....................................................72
BUSINESS GROUP
22
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
RESIDENTIAL PRODUCT RANGESUITE 1x1
“ELEGANCE AND COMFORT
FOR YOUR HOME”
We present the KAYSUN UK 2017 1x1 range of residential units. KAYSUN UK endeavours to offer the most complete range suitable for any type of aesthetic and requirement. Contributing to the maximum well-being of the user, at the vanguard of innovation and with a proposal that meets all of the requirements of the market and contains developments that constitute pioneering advances in the sector.
The residential range units comply with the ERP (energy-related products) directive of the EU, offering SCOP values of A, A+ and A++. The brand wishes to consolidate its position in the market by offering products with a seasonal energy
efficiency under heat mode that are even higher than 4 in SCOP for some of its models. Therefore, we not only observe the current directives on energy efficiency, but future directives as well.
INSTALLATION
MAINTENANCE
INTERACTIVITY
EFFICIENCY+
+
++
PRODIGYIn its search for the best combination of efficiency and comfort, KAYSUN UK brings professional technological development to the end-user. The PRODIGY unit has been created to become the new emblem of domestic split equipment, and is positioned in the market as an unbeatable commitment to our fundamental values.
RESIDENTIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
23
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
INSTALLING
• Installation template included and integral plate, strong and simple support. When installing the unit, you have a 50mm side shift margin.
• The unit's support is fitted with a hinge system, which provides a 168 mm opening to allow a comfortable cooling pipe connection.
MAINTENANCE
EASY AND COMFORTABLE ACCESS TO THE FILTER WITHOUT DISASSEMBLING THE UNIT
FAN MAINTENANCE WITHOUT TAKING THE UNIT OFF THE WALL.
SIMPLE AND QUICK OPENING THANKS TO ITS ROTATING FRONT PANEL.
EASY ACCESS TO EVAPORATOR IN CASE THAT CLEANING OR REPLACEMENT TASKS ARE REQUIRED.
EASY ACCESS TO ELECTRONIC BOARD AND TO THE COMPLETE ELECTRICAL PANEL TO PERFORM CHECKING OR REPLACEMENT OPERATIONS.
+
++
++
• Fasteners system for supporting front panel while working on electrical connections.
• The electric terminal board is wide and strong.
BUSINESS GROUP
24
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
AUREA II
This year KAYSUN UK presents AUREA II, its new medium-range unit, within its residential wall type units. With its elegant design, the main characteristic of this unit is that it functions with R-32 or R-410A refrigerant and incorporates all KAYSUN UK technology, with the most advanced functions in the range as a result.
WIFI CONTROL (OPTIONAL)+
R-32 AND R-410A REFRIGERANT+LEAKAGE DETECTION SYSTEMS
SCOP OVER 4.0++
PARAMETERS AND CONFIGURATION BY REMOTE CONTROLLER+
GREATER OUTPUT+ENERGY SAVING+SOUND LEVELS REDUCTION+R-410A AND R-32+
OUTDOOR UNITS
We wish to point out the whole range of outdoor units in the KAYSUN UK SUITE RANGE. These are units that provide us with low noise levels, good performance and significant energy savings. A machine designed to make maintenance tasks easier and protects/protecting its main components in order to extend the useful life of the product.
• Strong structure.
• Compact finishing.
NEW
RESIDENTIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
25
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
APP/WIFI
KAYSUN UK has a plug&play WiFi control system. Thanks to our USB accessory, you can quickly and easily configure your split unit through your smartphone.
KID-02 S
The KAYSUN UK SUITE 1X1 RANGE has wireless control of large services and with the most advanced functions.
INSTALLATION PARAMETRES MODIFICATION+OPERATION PARAMETERS CHECKING+FOLLOW ME+
WEEKLY TIMER+CHECK+BASIC FUNCTIONS+
www.kaysun.co.uk
KID-02 S
K03 WIFI USB ACCESSORY
DOWNLOAD OUR APPLICATION FROM:
PLUG & PLAY+
BUSINESS GROUP
26
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
SETSSUITE 1x1
27
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
2.6 5.23.5 7.1POWER kW
PRODIGY
AUREA II R-32
AUREA II R-410A
ONNIX
DOUBLE FLOW CONSOLE
KAY-26 DN7
KAY-D 26 DN7
KAY-S 26 DR7
KAY-S 26 DNR7
KAY-35 DN7
KAY-D 35 DN7
KSD-35 DVN10
KAY-S 35 DR7
KAY-S 35 DNR7
KAY-52 DN7
KAY-D 52 DN7
KSD-52 DVN10
KAY-S 52 DR7
KAY-S 52 DNR7
KAY-71 DN7
KAY-S 71 DR7
KAY-S 271DNR7
NEW
NEW
DISTANCES AND HEIGHT DIFFERENCES
26 35 52 71
TOTAL LENGTH 25 25 30 50
MAXIMUM HEIGHT 10 10 20 25
BUSINESS GROUP
28
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
ERP
PRODIGYPRODIGY is a KAYSUN UK wall unit that represents a revolution in installation and preventive maintenance*. Easy installation, maintenance and fitted with Kaysun avant-garde TECHNOLOGY.
• SCOP 4.0, over European Directive ERP, for a high energy efficiency.
• Louvres position memory.
• Leakage detection system.
• Compatible with wired controllers.
• Drainage pipe connection from left or right option.
• Self-locking option for Heating-Only function.
• Display and buzzer switch-off to improve ambient comfort.
• Its white translucent smart DISPLAY provides user with information on the equipment and alarm systems status.
• KID-02 S controller included to control unit’s work parameters and change its configuration.
• Mono-Multi compatible.
• Optional WIFI control adding K03 WIFI USB.
K01-WIFIKC-02.1 H KCT-02.1 SRKC-01 S
For further information, please see our Controllers range
INDIVIDUAL
CONTROLLERS
BMS AND SOFTWARE
GENERAL CHARACTERISTICS
WIFI CONTROL (OPTIONAL) +
EASY ASSEMBLY AND MAINTENANCE +ERP
KID-02 SSTANDARD
OPTIONAL WIFI
K03 WIFI USB ACCESSORY
PRICE LIST
SET INDOOR UNIT OUTDOOR UNIT STANDARD CONTROL PRICE SET
KAY-26 DN7 KAY-26 DN7 KAE-26 DN7 KID-02 S £391
KAY-35 DN7 KAY-35 DN7 KAE-35 DN7 KID-02 S £414
KAY-52 DN7 KAY-52 DN7 KAE-52 DN7 KID-02 S £757
KAY-71 DN7 KAY-71 DN7 KAE-71 DN7 KID-02 S £962
ACCESSORIES
MODEL PRICE
K03 WIFI USB ACCESSORY £36
SETSRESIDENTIAL RANGE
29
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
TECHNICAL SPECIFICATIONS
SET KAY-26 DN7 KAY-35 DN7 KAY-52 DN7 KAY-71 DN7Cooling capacity (min./rated/max.) kW 1.17/2.64/3.31 1.26/3.52/4.45 1.90/5.28/6.13 2.67/7.03/7.88
Cooling capacity (min./rated/max.) Kcal/h 1008/2268/2848 1084/3024/3830 1638/4536/5267 2293/6048/6779
Cooling input (min./rated/max.) W 100/816/1270 110/1153/1720 150/1633/2350 230/2306/3030
SEER 6.8 6.7 6.8 6.4
Cooling energy class A++ A++ A++ A++
Heating capacity (min./rated/max.) kW 0.82/2.93/3.72 1.07/3.81/4.86 1.43/5.57/6.74 2.08/7.62/9.14
Heating capacity (min./rated/max.) Kcal/h 706/2520/3200 917/3276/4183 1227/4788/5796 1789/6552/7862
Heating input (min./rated/max.) W 140/811/1330 170/1055/1740 230/1500/2400 310/2302/3270
SCOP 4.1 4.2 4.2 4.0
Heating efficiency class A+ A+ A+ A+
SCOP (warm areas) 5.1 5.2 5.4 5.2
Heating energy class (warm areas) A+++ A+++ A+++ A+++
Heating capacity -7ºC kW 2.12 2.30 3.89 4.95
COP -7ºC 2.88 2.79 2.78 2.48
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
INDOOR UNIT KAY-26 DN7 KAY-35 DN7 KAY-52 DN7 KAY-71 DN7Air Flow m3/h 472/360/254 563/497/224 870/730/500 1176/921/446
Sound pressure* dB (A) 20 22 26 28
Width x Height x Depth mm 717/302/193 805/302/193 964/325/222 1106/342/232
Net weight Kg 7 7.7 10.1 13.2
Power wiring mm2 From outdoor From outdoor From outdoor From outdoor
Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5
OUTDOOR UNIT KAE-26 DN7 KAY-35 DN7 KAY-52 DN7 KAY-71 DN7Compressor type Rotary Rotary Rotary Rotary
Outdoor airflow m3/h 1900 2000 2100 2700
Sound pressure dB (A) 55 56 58 61
Refrigerant R-410 R-410 R-410 R-410
Refrigerant charge / Supplementary charge ** gr 800/15 950/15 1480/15 2000/30
Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8")
Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") ø15.9(5/8")
Max. length piping m 25 25 30 50
Pipe height difference m 10 10 20 25
Width/Height/Depth mm 770/555/300 800/554/333 800/554/333 845/702/363
Net weight Kg 26.6 29.1 37.8 48.4
Power wiring mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5
* Sound pressure in “Silence” mode / **Factory pre-charge for 5 metres of installation / Additional charge for every metre added after 5 metres
Working temperature range: -15ºC to 50ºC (Cooling) / -20ºC to 30ºC (Heating)
BUSINESS GROUP
30
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
AUREA II R-410AAUREA II, the medium-category range of KAYSUN UK, is characterized by its multi-use nature: it can run on R-410A or R-32 refrigerant. In addition to a simple and elegant design, it incorporates all of KAYSUN’s most advanced characteristics and technologies.
• SCOP 4.0, over European Directive ERP, for a high energy efficiency.
• Louvres position memory.
• Leakage detection system.
• Drainage pipe connection from left or right option.
• Self-locking option for Heating-Only function.
• Display and buzzer switch-off to improve ambient comfort.
• White translucent smart DISPLAY with information on the equipment and alarm systems status.
• KID-02 S controller included to control unit's work parameters and change its configuration.
• Mono-Multi compatible.
• Easy installation optional WIFI control adding K03 WIFI USB.
For further information, please see our Controllers rangeCONTROLLERS
BMS AND SOFTWARE
K01-WIFI
GENERAL CHARACTERISTICS
POSSIBILITY TO BLOCK THE UNIT FOR HEATING-ONLY +WIFI CONTROL (OPTIONAL)+
NEW
KID-02 SSTANDARD
OPTIONAL WIFI
K03 WIFI USB ACCESSORY
PRICE LIST
SET INDOOR UNIT OUTDOOR UNIT STANDARD CONTROL PRICE SET
KAY-S 26 DNR7 KAY-S 26 DR7 KAE-26 DN7 KID-02 S £411
KAY-S 35 DNR7 KAY-S 35 DR7 KAE-35 DN7 KID-02 S £433
KAY-S 52 DNR7 KAY-S 52 DR7 KAE-52 DN7 KID-02 S £732
KAY-S 71 DNR7 KAY-S 71 DR7 KAE-71 DN7 KID-02 S £894
ACCESSORIES
MODEL PRICE
K03 WIFI USB ACCESSORY £36
SETSRESIDENTIAL RANGE
31
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
TECHNICAL SPECIFICATIONS
SET KAY-S 26 DNR7 KAY-S 35 DNR7 KAY-S 52 DNR7 KAY-S 71 DNR7Cooling capacity (min./rated/max.) kW 1.17/2.64/3.31 1.26/3.52/4.45 1.90/5.28/6.13 2.67/7.03/7.88
Cooling capacity (min./rated/max.) Kcal/h 1008/2268/2848 1084/3024/3830 1638/4536/5267 2293/6048/6779
Cooling input (min./rated/max.) W 90/750/1270 100/1088/1740 150/1547/2380 230/2261/3110
SEER 7.4 6.8 6.8 6.6
Cooling energy class A++ A++ A++ A++
Heating capacity (min./rated/max.) kW 0.82/2.93/3.72 1.07/3.81/4.86 1.43/5.57/6.74 2.08/7.62/9.14
Heating capacity (min./rated/max.) Kcal/h 706/2520/3200 917/3276/4183 1227/4788/5796 1789/6552/7862
Heating input (min./rated/max.) W 140/770/1340 170/1025/1760 220/1500/2430 320/2320/3320
SCOP 4.2 4.2 4 4
Heating energy class A+ A+ A+ A+
SCOP (warm areas) 5.4 5.2 5.3 5.2
Heating energy class (warm areas) A+++ A+++ A+++ A+++
Heating capacity -7ºC kW 2.12 2.30 3.89 4.95
COP -7ºC 2.88 2.79 2.78 2.48
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
OUTDOOR UNIT KAE-26 DN7 KAE-35 DN7 KAE-52 DN7 KAE-71 DN7Compressor type Rotary Rotary Rotary Rotary
Outdoor airflow m3/h 1900 2000 2100 2700
Sound pressure dB (A) 55 56 58 61
Refrigerant R-410 R-410 R-410 R-410
Refrigerant charge / Supplementary charge ** gr 800/15 950/15 1480/15 2000/30
Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8")
Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") ø15.9 (5/8")
Max. piping length m 25 25 30 50
Pipe height difference m 10 10 20 25
Width/Height/Depth mm 770/555/300 800/554/333 800/554/333 845/702/363
Net weight Kg 26.6 29.1 37.8 48.4
Power wiring mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5
INDOOR UNIT KAY-S 26 DR7 KAY-S 35 DR7 KAY-S 52 DR7 KAY-S 71 DR7Airflow m3/h 515/459/337 515/459/337 750/505/420 1050/750/560
Sound pressure* dB (A) 21 23 21 26
Width/Height/Depth mm 802/297/189 802/297/189 965/319/215 1080/335/226
Net weight Kg 8.2 8.2 9 12
Power wiring mm2 From outdoor From outdoor From outdoor From outdoor
Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5
*Sound pressure in “Silence” mode.
**Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres.
Working temperature range: -15ºC to 50ºC (Cooling) / -20ºC to 30ºC (Heating)
BUSINESS GROUP
32
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
AUREA II R-32AUREA II, the medium-category range of KAYSUN UK, is characterized by its versatile nature: it can run on R-410A or R-32 refrigerant. In addition to a simple and elegant design, it incorporates all of KAYSUN’s most advanced characteristics and technologies.
• SCOP 4.0, over European Directive ERP, for a high energy efficiency.
• Louvres position memory.
• Leakage detection system.
• Drainage pipe connection from left or right option.
• Self-locking option for Heating-Only function.
• Display and buzzer switch-off to improve ambient comfort.
• White translucent smart DISPLAY with information on the equipment and alarm systems status.
• KID-02 S controller included to control unit's work parameters and change its configuration.
• Mono-Multi compatible.
• Easy installation optional WIFI control adding K03 WIFI USB
For further information, please see our Controllers rangeCONTROLLERS
BMS AND SOFTWARE
K01-WIFI
GENERAL CHARACTERISTICS
NEW
POSSIBILITY TO BLOCK THE UNIT FOR HEATING-ONLY +WIFI CONTROL (OPTIONAL)+
KID-02 SSTANDARD
OPTIONAL WIFI
K03 WIFI USB ACCESSORY
PRICE LIST
SET INDOOR UNIT OUTDOOR UNIT STANDARD CONTROL PRICE SET
KAY-S 26 DR7 KAY-S 26 DR7 KAE-26 DR7 KID-02 S £473
KAY-S 35 DR7 KAY-S 35 DR7 KAE-35 DR7 KID-02 S £507
KAY-S 52 DR7 KAY-S 52 DR7 KAE-52 DR7 KID-02 S £839
KAY-S 71 DR7 KAY-S 71 DR7 KAE-71 DR7 KID-02 S £1,053
ACCESSORIES
MODEL PRICE
K03 WIFI USB ACCESSORY £36
SETSRESIDENTIAL RANGE
33
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
TECHNICAL SPECIFICATIONS
SET KAY-S 26 DR7 KAY-S 35 DR7 KAY-S 52 DR7 KAY-S 71 DR7Cooling capacity (min./rated/max.) kW 1.08/2.64/3.46 1.11/3.52/4.51 1.73/5.28/6.21 2.58/7.33/8.44
Cooling capacity (min./rated/max.) Kcal/h 932/2268/2974 958/3024/3881 1487/4536/5342 2218/6300/7257
Cooling input (min./rated/max.) W 70/712/1240 70/1004/1610 120/1900/2390 230/2500/3370
SEER 8.2 7.5 6.7 6.9
Cooling energy class A++ A++ A++ A++
Heating capacity (min./rated/max.) kW 0.88/2.93/3.90 0.88/3.81/4.92 1.06/5.57/6.98 1.52/7.62/9.44
Heating capacity (min./rated/max.) Kcal/h 756/2520/3352 756/3276/4234 907/4788/5997 1310/6552/8114
Heating input (min./rated/max.) W 140/697/1300 140/1002/1640 190/1860/2490 230/2425/3370
SCOP 4.6 4.6 4.0 4.0
Heating efficiency class A++ A++ A+ A+
SCOP (warm areas) 5.6 5.2 5.1 5.1
Heating energy class (warm areas) A+++ A+++ A+++ A+++
Heating capacity -7ºC kW 2.10 2.28 3.85 4.85
COP -7ºC 2.8 2.75 2.77 2.44
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
OUTDOOR UNIT KAE-26 DR7 KAE-35 DR7 KAE-52 DR7 KAE-71 DR7Compressor type Rotary Rotary Rotary Rotary
Outdoor airflow m3/h 2000 2000 2100 2700
Sound pressure dB (A) 55 55 57 59
Refrigerant R-32 R-32 R-32 R-32
Refrigerant charge / Supplementary charge ** gr 650 / 12 650 / 12 1250 / 12 1600 / 24
Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8")
Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") ø15.9(5/8")
Max. piping length m 25 25 30 50
Pipe height difference m 10 10 20 25
Width/Height/Depth mm 800/554/333 800/554/333 800/554/333 845/700/320
Net weight Kg 37 37 37 48
Power wiring mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5
INDOOR UNIT KAY-S 26 DR7 KAY-S 35 DR7 KAY-S 52 DR7 KAY-S 71 DR7Air Flow m3/h 515/459/337 515/459/337 750/505/420 1050/750/560
Sound pressure* dB (A) 21 23 21 26
Width/Height/Depth mm 802/297/189 802/297/189 965/319/215 1080/335/226
Net weight Kg 8.2 8.2 9 12
Power wiring mm2 From outdoor From outdoor From outdoor From outdoor
Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5
*Sound pressure in “Silence” mode.
**Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres.
Working temperature range: -15ºC to 50ºC (Cooling) / -25ºC to 30ºC (Heating)
BUSINESS GROUP
34
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
ERP
ONNIX
K01-WIFI
CONTROLLERS
BMS AND SOFTWARE
Its original V-shape design, dark shade finishing and mirror-effect front side provide this unit with a very attractive modern appearance. The unit opens automatically when it switches on to increase airflow, and it closes when it switches off to recover its compact appearance.
• SCOP 4.0, over European Directive ERP, for a high energy efficiency.
• A brightness sensor regulates the display’s intensity.
• Louvres position memory.
• Leakage detection system.
• Drainage pipe connection from left or right option.
• Self-locking option for Heating-Only function.
• White translucent smart DISPLAY with information on the equipment and alarm systems status.
• KID-02 S controller included to control unit's work parameters and change its configuration.
• Mono-Multi compatible.
• Optional WIFI control adding K03 WIFI USB.
GENERAL CHARACTERISTICS
BRIGHTNESS SENSOR +
WIFI CONTROL (OPTIONAL) +
For further information, please see our Controllers range
KID-02 SSTANDARD
OPTIONAL WIFI
K03 WIFI USB ACCESSORY
PRICE LIST
SET INDOOR UNIT OUTDOOR UNIT STANDARD CONTROL PRICE SET
KAY-D 26 DN7 KAY-D 26 DN7 KAE-26 DN7 KID-02 S £498
KAY-D 35 DN7 KAY-D 35 DN7 KAE-35 DN7 KID-02 S £530
KAY-D 52 DN7 KAY-D 52 DN7 KAE-52 DN7 KID-02 S £883
ACCESSORIES
MODEL PRICE
K03 WIFI USB ACCESSORY £36
SETSRESIDENTIAL RANGE
35
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
* Sound pressure in “Silence” mode / **Factory pre-charge for 5 metres installation / Additional charge for every metre added after 5 metres.
Working temperature range: -15ºC to 50ºC (Cooling) / -20ºC to 30ºC (Heating)
TECHNICAL SPECIFICATIONS
SET KAY-D 26 DN7 KAY-D 35 DN7 KAY-D 52 DN7Cooling capacity (min./rated/max.) kW 1.23/2.64/3.30 1.33/3.52/4.47 1.83/5.28/6.12
Cooling capacity (min./rated/max.) Kcal/h 1057/2270/2838 1144/3027/3844 1574/4541/5263
Cooling input (min./rated/max.) W 100/712/1260 100/1095/1710 140/1643/2345
SEER 7.4 6.9 6.6
Cooling energy class A++ A++ A++
Heating capacity (min./rated/max.) kW 0.85/2.93/3.72 1.04/3.81/4.88 1.40/5.57/6.53
Heating capacity (min./rated/max.) Kcal/h 731/2520/3199 894/3276/4197 1204/4790/5616
Heating input (min./rated/max.) W 130/792/1320 160/1117/1730 212/1542/2390
SCOP 4.1 4.1 4.1
Heating efficiency class A+ A+ A+
SCOP (warm areas) 5.3 5.2 5.3
Heating energy class (warm areas) A+++ A+++ A+++
Heating capacity -7ºC kW 2.31 2.43 3.75
COP -7ºC 2.76 2.81 2.82
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50
INDOOR UNIT KAY-D 26 DN7 KAY-D 35 DN7 KAY-D 52 DN7Air Flow m3/h 400/300/240 500/350/270 710/620/480
Sound pressure* dB (A) 20 20 23
Width/Height/Depth mm 897/312/182 987/312/182 1004/350/205
Net weight Kg 9.5 9.9 13
Power wiring mm2 From outdoor From outdoor From outdoor
Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5
OUTDOOR UNIT KAE-26 DN7 KAE-35 DN7 KAE-52 DN7Compressor type Rotary Rotary Rotary
Outdoor airflow m3/h 1900 2000 2100
Sound pressure dB (A) 55 55 56
Refrigerant R-410 R-410 R-410
Refrigerant charge / Supplementary charge ** gr 800/15 950/15 1480/15
Liquid pipe diameter mm (Inch) Ø6.35 (1/4") Ø6.35 (1/4") Ø6.35 (1/4")
Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") Ø12.7 (1/2")
Max. piping length m 25 25 30
Pipe height difference m 10 10 20
Width/Height/Depth mm 770/550/300 800/554/333 800/554/333
Net weight Kg 26.6 29.1 37.8
Power wiring mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5
BUSINESS GROUP
36
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
DOUBLE FLOW CONSOLE
CONTROLLERS
The double flow console has an elegant and compact design that allows for the adaptation thereof to any area to be air-conditioned. It is fitted with the latest technological features, thereby providing users with a high comfort level.
• Double air supply
• Four air intakes
• Silent unit
• DC Inverter fan motor with 5 speeds.
• Voltage-free alarm and ON/OFF dry contacts.
• Optional wired controller.
K01-LON K01-BACNET K01-KNXKAYNET CONTROL K01-WIFI INDOOR XYE ON
BMS AND SOFTWARE ACCESORY
INDIVIDUAL
For further information, please see our Controllers range
CENTRALISED
KID-02 S KCT-02.1 SRKC-02.1 H KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB
KID-02 S(*) RECOMMENDED
GENERAL CHARACTERISTICS
ERP
K02-MODBUS
KC-01 S
(*) Price calculation based on the recommended controller.
PRICE LIST
SET INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE SET £
KSD-35 DVN10 KSD-35 DN6 KUE-35 DVN10 KID-02 S £790
KSD-52 DVN10 KSD-52 DMNU8 KAE-52 DN7 KID-02 S £953
SETSRESIDENTIAL RANGE
37
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
SET KSD-35 DVN10 KSD-52 DVN10Cooling capacity (min./rated/max.) kW 0.62/3.52/4.40 0.73/4.69/5.57
Cooling capacity (min./rated/max.) Kcal/h 533/3026/3783 630/4032/4788
Cooling input (min./rated/max.) W 211/1030/1690 240/1670/2200
SEER 6.1 5.3
Cooling energy class A++ A
Heating capacity (min./rated/max.) kW 0.62/3.81/4.95 0.82/5.00/6.30
Heating capacity (min./rated/max.) Kcal/h 533/3276/4256 705/4299/5417
Heating input (min./rated/max.) W 190/1000/1760 270/1550/2150
SCOP 4.0 3.8
Heating efficiency class A+ A
SCOP (warm areas) 5.1 4.6
Heating energy class (warm areas) A+++ A++
Heating capacity -7ºC kW 3.18 3.52
COP -7ºC 2.73 2.48
Power supply V / F / Hz 220-240/1/50 220-240/1/50
OUTDOOR UNIT KUE-35 DVN10 KAE-52 DN7Compressor type Rotary Rotary
Outdoor airflow m3/h 2000 2100
Sound pressure dB (A) 57 56
Refrigerant R-410 R-410
Refrigerant charge / Supplementary charge ** gr 1380 / 15 1480/15
Liquid pipe diameter mm (Inch) Ø6.35 (1/4") Ø6.35 (1/4")
Gas pipe diameter mm (Inch) Ø9.52 (3/8") Ø12.7 (1/2")
Max. piping length m 25 30
Pipe height difference m 10 20
Width/Height/Depth mm 800/554/333 800/554/333
Net weight Kg 34.5 37.8
Power wiring mm2 (2+T)x2.5 (2+T)x2.5
Communication wiring mm2 (3+T)x2.5 (4+T)x2.5
INDOOR UNIT KSD-35 DN6 KSD-52 DMNU8Air Flow m3/h 550/470/360 590/540/480
Sound pressure* dB (A) 35 35
Width/Height/Depth mm 700/600/210 700/600/210
Net weight Kg 15 15
Power wiring mm2 From outdoor From outdoor
Communication wiring mm2 (3+T)x2.5 (3+T)x2.5
*Sound pressure at low speed.
**Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres.
Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
TECHNICAL SPECIFICATIONS
BUSINESS GROUP
38
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
RESIDENTIAL PRODUCT RANGEMULTISYSTEM SUITE
“ELEGANCE AND COMFORT
FOR YOUR HOME”
Introducing the KAYSUN UK 2017 Multisystem DC Inverter designed to provide comfort and technology to every space. Available in R-410A and R-32. This is a flexible and versatile range that allows multiple combinations with different types of indoor units. This range is also affected by the European Directive ERP regarding equipment of less than 8 kW, with which is compliant thanks to the technological development of its components. All external units are fitted with a DC Inverter compressor and fan motor, while all internal units also have a DC Inverter fan motor.
These units are the solution for small spaces in which a larger scale installation is not possible. They allow for combinations containing up to 5 indoor units.
We have more or fewer combinations, depending on the gas refrigerant. With R-410 A, we can create combinations of different indoors: Wall-mounted (PRODIGY, ONNIX, AUREA II models), Cassette ArtFlux 360º, duct and double flow console with capacities from 2 to 7.1 kW. In R-32, for the time being we only have wall-mounted units (AUREA II) with capacities from 2.6 to 7.1 kW.
APP/WIFIKAYSUN UK has a plug&play WiFi control system. Thanks to our USB accessory, you can quickly and easily configure your split unit through your smartphone.
OUTDOOR UNITSThe residential product range has external units with a robust design designed to make maintenance easier and to protect its main components, so as to extend the useful life of the product.
WEEKLY TIMER+CHECK+BASIC FUNCTIONS+
K03 WIFI USB ACCESSORY
PLUG & PLAY+
ERP
R-32 AND R-410A REFRIGERANT+STRONGER+LOW SOUND LEVELS+
www.kaysun.co.uk
DOWNLOAD OUR APPLICATION FROM:
INTRODUCTION TO THE RANGE OF PRODUCTSRESIDENTIAL RANGE
39
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
SMART CONTROLLERSThe KAYSUN UK multisystem range has controls on the altitude, innovation and technology of units in the range. The cable and wireless controls have the most technologically-advanced functions and utilities, but with a modern and avant-garde aesthetic.
ADVANACED AESTHETIC+
WEEKLY TIMER
FOLLOW ME+
KC-03 SPS
INSTALLATION PARAMETRES MODIFICATION+OPERATION PARAMETERS CHECKING+FOLLOW ME
KID-02 S
DISTANCES AND HEIGHT DIFFERENCES
2X1 3X1 4X1 5X1
TOTAL LENGTH 40 60 80 80
MAXIMUM HEIGHT 15
MAXIMUM DISTANCEPER OUTPUT
25 30 35 35
+
+
BUSINESS GROUP
40
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
2.0 3.52.6 5.2 7.1POWER KW
DUCTS
KAY-26 DN7
KAY-S 26 DR7
KPD-26 DMN7KPD-20 DMN7
KCI-26 DMN7
KSD-26 DMN6
KAY-D 26 DN7
KAY-35 DN7
KAY-S 35 DR7
KPD-35 DN10
KCI-35 DN10
KSD-35 DN6
KAY-D 35 DN7
KAY-52 DN7
KAY-S 52 DR7
KPD-52 DMNU8
KCI-52 DMNU9
KSD-52 DMNU8
KAY-D 52 DN7
KAY-71 DN7
KAY-S 71 DR7
KPD-71 DMNU8
KCIS-71 DMNU9
PRODIGY
AUREA II
ONNIX
DOUBLE FLOW CONSOLE
CASSETTE
Nº OF INDOOR UNITS
2
3
4
5
4.2 6.25.2 7.8 8.0 10.5 12.0POWER KW
KAM3-78 DN7KAM3-62 DN7
KAM2-52 DN7KAM2-42 DN7
KAM4-80 DN7 KAM4-105 DN7
KAM5-120 DN7
R-410A MULTISYSTEM
INDOOR UNITS
OUTDOOR UNITS
NEW
INTRODUCTION TO THE RANGE OF PRODUCTSRESIDENTIAL RANGE
41
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
2.0 3.52.6 5.2 7.1POWER KW
KAY-S 26 DR7 KAY-S 35 DR7 KAY-S 52 DR7 KAY-S 71 DR7
AUREA II
Nº OF INDOOR UNITS
2
3
4
5
4.2 6.25.2 7.8 8.0 10.5 12.0POWER KW
KAM3-78 DR7
KAM2-52 DR7
KAM4-105 DR7
KAM5-120 DR7
R-32 MULTISYSTEM
INDOOR UNITS
OUTDOOR UNITS
NEW
NEW
BUSINESS GROUP
42
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
TECHNICAL SPECIFICATIONS
PRODIGY R-410A MULTISYSTEM
MODEL KAY-26 DN7 KAY-35 DN7 KAY-52 DN7 KAY-71 DN7Cooling capacity kW 2.64 3.52 5.28 7.03
Cooling capacity Kcal/h 2268 3024 4536 6048
Heating capacity kW 2.93 3.81 5.57 7.33
Heating capacity Kcal/h 2520 3276 4788 6300
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
Airflow m³/h 472/360/254 563/497/224 870/730/500 1176/921/446
Sound pressure* dB (A) 20 22 26 28
Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8")
Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") ø15.9(5/8")
Width/Height/Depth mm 717/302/193 805/302/193 964/325/222 1106/342/232
Net weight Kg 7 7.7 10.1 13.2
Power wiring mm2 From outdoor From outdoor From outdoor From outdoor
Communication wiring mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5
*Sound pressure in “Silence” mode.
INDOOR UNITSRESIDENTIAL RANGE
43
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
ERP
K01-WIFIKC-02.1 HKC-01 S
For further information, please see our Controllers range
INDIVIDUAL
CONTROLLERS
BMS AND SOFTWARE
GENERAL CHARACTERISTICS
PRODIGY is a KAYSUN UK wall unit that represents a revolution in installation and preventive maintenance*. Easy installation, maintenance and fitted with Kaysun avant-garde technology.
• Optional WIFI control adding K03 WIFI USB.
• Mono-Multi compatible.
• White translucent smart DISPLAY with information on the equipment and alarm systems status.
• The display and buzzer have a switch-off option which can be activated if they annoy the user.
• KID-02 S controller included to control unit's work parameters and change its configuration.
• Louvres position memory.
• Drainage pipe connection from left or right option.
• Compatible with wired controllers.
* For further information, please check the Presentation section of this manual.
KID-02 SSTANDARD
K03 WIFI USB ACCESSORY
KCT-02.1 SR
WIFI CONTROL (OPTIONAL)+
COMPATIBLE WITH
MULTISYSTEM OUTDOOR UNITS
see pag. 58
EASY ASSEMBLY AND MAINTENANCE +
OPTIONAL WIFI
PRICE LIST
MODEL STANDARD CONTROLLER PRICE
KAY-26 DN7 KID-02 S £110
KAY-35 DN7 KID-02 S £121
KAY-52 DN7 KID-02 S £182
KAY-71 DN7 KID-02 S £246
ACCESSORIES
MODEL PRICE
K03 WIFI USB ACCESSORY £36
BUSINESS GROUP
44
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
*Sound pressure in “Silence” mode.
AUREA II R-410A MULTISYSTEM
TECHNICAL SPECIFICATIONS
MODEL KAY-S 26 DR7 KAY-S 35 DR7 KAY-S 52 DR7 KAY-S 71 DR7
Cooling capacity kW 2.64 3.52 5.28 7.03
Cooling capacity Kcal/h 2268 3024 4536 6048
Heating capacity kW 2.93 3.81 5.57 7.64
Heating capacity Kcal/h 2520 3276 4788 6552
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
Airflow m3/h 515/459/337 515/459/337 750/505/420 1050/750/560
Sound pressure* dB (A) 21 23 21 26
Width/Height/Depth mm 802/297/189 802/297/189 965/319/215 1080/335/226
Net weight Kg 8.2 8.2 9 12
Power wiring mm2 From outdoor From outdoor From outdoor From outdoor
Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5
NEW
INDOOR UNITSRESIDENTIAL RANGE
45
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
ERP
BMS AND SOFTWARE
CONTROLS
K01-WIFI
GENERAL CHARACTERISTICS
AUREA II, the medium category range of KAYSUN UK, is characterised by its multi-use nature: it can run on R-410A or R-32 refrigerant. In addition to a simple and elegant design, it incorporates all of KAYSUN’s most advanced characteristics and technologies.
• Optional WIFI control adding K03 WIFI USB.
• Mono-Multi compatible.
• White translucent smart DISPLAY with information on the equipment and alarm systems status.
• The display and buzzer have a switch-off option which can be activated if they annoy the user.
• KID-02 S controller included to control unit's work parameters and change its configuration.
• Louvres position memory.
• Drainage pipe connection from left or right option.
WIFI CONTROL (OPTIONAL)+
21 dB SOUND PRESSURE+
K03 WIFI USB ACCESSORY
OPTIONAL WIFIKID-02 S
STANDARD
COMPATIBLE WITH
MULTISYSTEM OUTDOOR UNITS
see pag. 58
PRICE LIST
MODEL STANDARD CONTROLLER PRICE
KAY-S 26 DR7 KID-02 S £131
KAY-S 35 DR7 KID-02 S £139
KAY-S 52 DR7 KID-02 S £239
KAY-S 71 DR7 KID-02 S £277
ACCESSORIES
MODEL PRICE
K03 WIFI USB ACCESSORY £36
BUSINESS GROUP
46
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
*Sound pressure in “Silence” mode.
ONNIX R-410A MULTISYSTEM
TECHNICAL SPECIFICATIONS
MODEL KAY-D 26 DN7 KAY-D 35 DN7 KAY-D 52 DN7
Cooling capacity kW 2.64 3.52 5.28
Cooling capacity Kcal/h 2268 3024 4536
Heating capacity kW 2.93 3.81 5.57
Heating capacity Kcal/h 2520 3276 4788
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50
Airflow m3/h 400/300/240 500/350/270 740/620/480
Sound pressure* dB (A) 20 20 28
Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4")
Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2")
Width/Height/Depth mm 897/182/312 897/182/312 1004/205/350
Net weight Kg 9.5 9.9 13.0
Power wiring mm2 From outdoor From outdoor From outdoor
Communication wiring mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5
INDOOR UNITSRESIDENTIAL RANGE
47
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
ERP
KID-02 SSTANDARD
BMS AND SOFTWARE
CONTROLS
K01-WIFI
GENERAL CHARACTERISTICS
Onnix, the top-end range of KAYSUN UK in wall-mounted units. Its original V-shape design, dark shade finishing and mirror-effect front side provide this unit with a very attractive modern appearance. The unit opens automatically when it switches on to increase airflow and it closes when it switches off to recover its compact appearance.
• A brightness sensor regulates the display's intensity.
• KID-02 S controller included to control unit's work parameters and change its configuration.
• Louvres position memory.
• Optional WIFI control adding K03 WIFI USB.
• Mono-Multi compatible.
• Drainage pipe connection from left or right option.
K03 WIFI USB ACCESSORY
WIFI CONTROL (OPTIONAL)+
20 dB SOUND PRESSURE+
OPTIONAL WIFI
COMPATIBLE WITH
MULTISYSTEM OUTDOOR UNITS
see pag. 58
PRICE LIST
MODEL STANDARD CONTROLLER PRICE
KAY-D 26 DN7 KID-02 S £218
KAY-D 35 DN7 KID-02 S £237
KAY-D 52 DN7 KID-02 S £309
ACCESSORIES
MODEL PRICE
K03 WIFI USB ACCESSORY £36
BUSINESS GROUP
48
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
MODEL KSD-26 DMN6 KSD-35 DN6 KSD-52 DMNU8
Cooling capacity kW 2.64 3.46 5.28
Cooling capacity Kcal/h 2270 2976 4536
Heating capacity kW 2.93 3.46 5.57
Heating capacity Kcal/h 2520 2976 4788
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50
Airflow m³/h 680/580/450 550/470/360 740/650/520
Sound pressure* dB (A) 35 36 39
Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4")
Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2")
Width/Height/Depth mm 700/600/210 700/600/210 700/600/210
Net weight Kg 13.5 15 15
Power wiring mm2 From outdoor From outdoor From outdoor
Communication wiring mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5
*Sound pressure data at low speed.
DOUBLE FLOW CONSOLE R-410A MULTISYSTEM
TECHNICAL SPECIFICATIONS
INDOOR UNITSRESIDENTIAL RANGE
49
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
The double flow console has an elegant and compact design that allows for the adaptation thereof to any area to be air-conditioned. This unit has the best technological features and its adaptability cover the needs of every user.
• DC Inverter fan MOTOR.
• Double air supply and four air intakes.
• Voltage-free alarm and ON/OFF dry contacts.
• Easy installation.
• Optional wired controller.
UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, add to the € price for the set the price difference
between the recommended controller and the selected controller.
ELIGE TU CONTROL
ERP
KC-01 S KCC-16
CENTRALISED
KCCT-64 I
INDIVIDUAL
BMS AND SOFTWARE
K01-LON K01-BACNET KAYNET CONTROL
KCC-64 I-PS
K01-KNX K01-WIFI
CONTROLS
GENERAL CHARACTERISTICS
DOUBLE AIR INTAKE +
RECOMMENDED
KID-02 S
KCT-02.1 SRKID-02 S KCC-64 WEB
For further information, please see our Controllers range
K02-MODBUS
KC-02.1 H
Enquire about availability and price.
CHOOSE YOUR CONTROL
COMPATIBLE WITH
MULTISYSTEM OUTDOOR UNITS
see pag. 58
PRICE LIST
MODEL RECOMMENDED CONTROLLER PRICE
KSD-26 DMN6 KID-02 S £247
KSD-35 DN9 KID-02 S £275
KSD-52 DMNU8 KID-02 S £303
(*) Price calculation based on the recommended controller.
BUSINESS GROUP
50
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
MODEL KCI-26 DMN8 KCI-35 DN10 KCI-52 DMNU9 KCIS-71 DMNU9
Cooling capacity kW 2.64 3.52 4.98 7.03
Cooling capacity Kcal/h 2268 3024 4284 6048
Heating capacity kW 2.93 4.1 5.57 7.33
Heating capacity Kcal/h 2520 3528 4788 6300
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
Airflow m3/h 580/500/450 650/530/450 680/560/500 1520/1350/1200
Sound pressure* dB (A) 33.5 34 41 43
Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8")
Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") ø15.9 (5/8")
Width/Height/Depth mm 570/260/570 570/260/570 570/260/570 840/245/840
Net weight Kg 14.5 16 16.1 24.0
Panel width/height/depth mm 647/50/647 647/50/647 647/50/647 950/55/950
Panel net weight Kg 2.5 2.5 2.5 5.0
Power wiring mm2 From outdoor From outdoor From outdoor From outdoor
Communication wiring mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5
CASSETTE ART FLUX 360º R-410A MULTISYSTEM
TECHNICAL SPECIFICATIONS
*Sound pressure at low speed.
INDOOR UNITSRESIDENTIAL RANGE
51
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
Cassette Art Flux 360º units have an impeccable design. Its 360º airflow provides user with maximum comfort covering every single corner of the room.
• They are fitted with an up to 500 mm high standard condensation pump.
• Voltage-free alarm and ON/OFF dry contacts.
• The right and left sides of these units' body are designed to connect the necessary piping to air-condition an adjacent room.
• The units supply 10 % to 15 % of outdoor airflow directly to the unit return system.
• The electric box is located at the lower side of the unit to get a more compact size and embeds the unit easily in the ceiling.
ERP
CENTRALISEDINDIVIDUAL
BMS AND SOFTWARE
For further information, please see our Controllers rangeCONTROLS
GENERAL CHARACTERISTICS
KCC-16KCCT-64 I KCC-64 I-PS KCC-64 WEB
K01-LON K01-BACNET KAYNET CONTROL K01-KNX K01-WIFI
RECOMMENDED
KID-02 S
KID-02 S
K02-MODBUS
KC-03 SPS
500mm CONDENSATION PUMP +
OUTDOOR AIR SUPPLY (10-15%)+
UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you shall add to the € price for the set, the price
difference between the recommended controller and the selected controller.ELIGE TU CONTROL
CHOOSE YOUR CONTROL
COMPATIBLE WITH
MULTISYSTEM OUTDOOR UNITS
see pag. 58
PRICE LIST
MODEL RECOMMENDED CONTROLLER PRICE
KCI-26 DMN8 KID-02 S £427
KCI-35 DN10 KID-02 S £458
KCI-52 DMNU9 KID-02 S £532
KCIS-71 DMNU9 KID-02 S £650
(*) Price calculation based on the recommended controller.
BUSINESS GROUP
52
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
33
DUCTS R-410A MULTISYSTEM
TECHNICAL SPECIFICATIONS
MODEL KPD-20 DMN7 KPD-26 DMN7 KPD-35 DN10 KPD-52 DMNU8 KPD-71 DMNU8
Cooling capacity kW 2.05 2.64 3.52 4.98 7.03
Cooling capacity Kcal/h 1764 2268 3024 4284 6048
Heating capacity kW 2.34 2.93 3.81 5.57 7.33
Heating capacity Kcal/h 2016 2520 3276 4788 6300
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
Airflow m3/h 530/400/340 530/400/340 680/580/450 858/728/623 1510/1280/1090
Static (rated) pressure range Pa 0-40(25) 0-40(25) 0-40(25) 0-60(25) 0-80(25)
Sound pressure* dB (A) 30.9 28.0 35.0 30.0 37.0
Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8")
Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") ø15.9 (5/8")
Width/Height/Depth mm 700/210/635 700/210/635 700/210/635 920/210/635 920/270/635
Net weight Kg 18.5 18.5 18.5 23 28
Power wiring mm2 From outdoor From outdoor From outdoor From outdoor From outdoor
Communication wiring mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5
*Sound pressure at low speed.
INDOOR UNITSRESIDENTIAL RANGE
53
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
The tilted evaporator of the KAYSUN UK Ducts provides them with a very slim design. This feature allows for installing Ducts units in areas where the false ceiling is too narrow.
• The filter is easy to remove even when piping is in place.
• All units include an air inlet/outlet frames to facilitate the fitting of the air ducts.
• The units have the possibility to make an outdoor air intake directly to the unit.
• The electric box of Duct type indoor units is removable up to 1 metre.
• They are fitted with an up to 500 mm high standard condensation pump.
• Voltage-free alarm and ON/OFF dry contacts.
Compatible con
KC-03 SPSRECOMMENDED
ERP
KCC-16KCCT-64 I
CENTRALISEDINDIVIDUAL
BMS AND SOFTWARE
K01-LON K01-BACNET KAYNET CONTROL
KCC-64 I-PS
K01-KNXK01-WIFI
For further information, please see our Controllers rangeCONTROLS
GENERAL CHARACTERISTICS
750mm CONDENSATION PUMP +
OUTDOOR AIR INTAKE+
KC-02.1 HKCT-02.1 SRKCC-64 WEB
KC-03 SPS
K02-MODBUS
KID-02 S KC-01 S
UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you shall add to the € price for the set, the price
difference between the recommended controller and the selected controller.ELIGE TU CONTROL
CHOOSE YOUR CONTROL
COMPATIBLE WITH
MULTISYSTEM OUTDOOR UNITS
see pag. 58
PRICE LIST
MODEL RECOMMENDED CONTROL PRICE
KPD-20 DMN7 KC-03 SPS £329
KPD-26 DMN7 KC-03 SPS £332
KPD-35 DN10 KC-03 SPS £346
KPD-52 DMNU8 KC-03 SPS £353
KPD-71 DMNU8 KC-03 SPS £375
(*) Price calculation based on the recommended controller.
BUSINESS GROUP
54
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
DUCT R-410A MULTISYSTEM
STATIC PRESSURE GRAPHS
KPD-20 DMN7
KPD-26 DMN7
KPD-35 DN10
STATIC PRESSURE GRAPHSRESIDENTIAL RANGE
55
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
KPD-52 DMNU8
KPD-71 DMNU8
BUSINESS GROUP
56
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
Note: Standard performance data; definitive performance data depend on the combination of indoor units.
MODEL KAM2-42 DN7 KAM2-52 DN7 KAM3-62 DN7 KAM3-78 DN7Cooling capacity kW 4.10 5.28 6.15 7.91
Cooling capacity Kcal/h 3526 4536 5292 6804
Cooling input kW 1.25 1.60 1.91 2.46
Heating capacity kW 4.40 5.57 6.59 8.21
Heating capacity Kcal/h 3784 4788 5670 7056
Heating input kW 1.15 1.59 1.78 2.27
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
Compressor type Rotary Rotary Rotary Rotary
Outdoor airflow m3/h 2100 2100 2700 3500
Sound pressure dB (A) 54 58 55 58
Refrigerant R-410 A R-410 A R-410 A R-410 A
Additional refrigerant charge* gr 1250 1700 2100 2100
Pre-charge metres* m 10 10 15 15
Liquid pipe diameter mm (Inch) ø6.35 (1/4") x 2 ø6.35 (1/4") x 2 ø6.35 (1/4") x 3 ø6.35 (1/4") x 3
Gas pipe diameter mm (Inch) ø9.52 (3/8") x 2 ø9.52 (3/8") x 2 ø9.52 (3/8") x 3 ø9.52 (3/8") x 3
Piping max. length m 40 40 60 60
Piping max. length (1 indoor unit) m 25 25 30 30Height difference between indoor and outdoor units
m 15 15 15 15
Height difference between indoor units m 10 10 10 10
Width/Height/Depth mm 800/554/333 800/554/333 845/702/363 845/702/363
Net weight Kg 30.5 30.5 47.0 52.7
Maximum number of indoor units 2 2 3 3
Power wiring mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x4
Communication wiring mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5
OUTDOOR UNITS
TECHNICAL SPECIFICATIONS
*To calculate the additional load necessary for these units, we applied the following formula:
ADDITIONAL LOAD (GR) = (TOTAL LENGTH OF ALL CIRCUITS' LIQUID LINE OF ¼” x 15 Grams) + (TOTAL LENGTH OF LIQUID LINE OF 3/8”
x 30 Grams) - (TOTAL LENGTH OF FACTORY PRELOAD CHARGE x 15 Grams).
ERP
KAYSUN UK MULTISYSTEM outdoor units, with their new appearance and stronger structure, provide greater output with less noise pollution.
QUIET+
STRONG +
R-410A MULTISYSTEM
RESIDENTIAL RANGE OUTDOOR UNIT
57
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
KAM4-80 DN7 KAM4-105 DN7 KAM5-120 DN78.21 10.55 12.31
7056 9072 10584
2.55 3.62 3.82
8.79 11.14 12.60
7560 9576 10836
2.43 3.17 3.31
220-240/1/50 220-240/1/50 220-240/1/50
Rotary Rotary Rotary
3800 5500 5500
55 58 58
R-410 A R-410 A R-410 A
2400 3000 3600
20 20 25
ø6.35 (1/4") x 4 ø6.35 (1/4") x 4 ø6.35 (1/4") x 5
ø9.52 (3/8”) x 3 + ø12.7 (1/2”) x 1 ø9.52 (3/8") x 3 + ø12.7 (1/2") x 1 ø9.52 (3/8") x 3 + ø12.7 (1/2") x 2
80 80 80
35 35 35
15 15 15
10 10 10
946/810/410 946/810/410 946/810/410
67.6 70.0 76.0
4 4 5
(2+T)x4 (2+T)x6 (2+T)x6
(3+T)x2.5 (3+T)x2.5 (3+T)x2.5
PRICE LIST
MODEL PRICE
KAM2-42 DN7 £665
KAM2-52 DN7 £793
KAM3-62 DN7 £968
KAM3-78 DN7 £1,124
KAM4-80 DN7 £1,243
KAM4-105 DN7 £1,543
KAM5-120 DN7 £1,843
BUSINESS GROUP
58
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
KAM2-42 DN7
20 20+20
26 20+26
35 20+35
52 26+26
26+35
x1 x2
COMBINED SYSTEMS
KAM2-52 DN7
20 20+20
26 20+26
35 20+35
52 20+52
26+26
26+35
26+52
35+35
x1 x2
R-410A MULTISYSTEM
RESIDENTIAL RANGE COMBINED SYSTEMS
59
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
COMBINATIONS RATED POWER (kW) COOLING CAPACITY (kW) INPUT POWER (kW)EER
(W/W)SEER ENERGY CLASS
1x2
UNIT A
UNIT B
UNIT A
UNIT B
MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY
20 20 2.05 2.05 1.76 4.10 4.54 0.42 1.24 1.43 3.30 6.10 A++
20 26 1.79 2.31 1.76 4.10 4.54 0.42 1.24 1.43 3.30 6.10 A++
20 35 1.51 2.59 1.76 4.10 4.54 0.42 1.23 1.43 3.32 6.10 A++
26 26 2.05 2.05 1.76 4.10 4.54 0.42 1.24 1.43 3.30 6.10 A++
26 35 1.76 2.34 1.76 4.10 4.54 0.42 1.23 1.43 3.32 6.10 A++
COMBINATIONS RATED POWER (kW) HEATING POWER (kW) INPUT POWER (kW)COP
(W/W)SCOP
ENERGY CLASS
COP -7
1x2
UNIT A
UNIT B
UNIT A
UNIT B
MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUMRATED
CAPACITY
20 20 2.20 2.20 1.89 4.40 4.87 0.39 1.16 1.33 3.80 4.00 A+ 3.15
20 26 1.93 2.48 1.89 4.40 4.87 0.39 1.16 1.33 3.80 4.00 A+ 3.15
20 35 1.66 2.84 1.89 4.50 4.98 0.39 1.19 1.33 3.78 4.00 A+ 3.13
26 26 2.20 2.20 1.89 4.40 4.87 0.39 1.16 1.33 3.80 4.00 A+ 3.15
26 35 1.93 2.57 1.89 4.50 4.98 0.39 1.19 1.33 3.78 4.00 A+ 3.13
COMBINATIONS RATED POWER (kW) COOLING CAPACITY (kW) INPUT POWER (kW)EER
(W/W)SEER ENERGY CLASS
1x2
UNIT A
UNIT B
UNIT A
UNIT B
MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUMRATED
CAPACITY
20 20 2.10 2.10 2.08 4.20 5.51 0.59 1.27 2.16 3.31 6.20 A++
20 26 2.06 2.64 2.08 4.70 5.72 0.59 1.46 2.16 3.23 6.20 A++
20 35 1.95 3.35 2.08 5.30 6.29 0.59 1.82 2.16 2.91 6.10 A++
20 52 1.51 3.92 2.08 5.40 6.34 0.59 1.77 2.16 3.05 6.10 A++
26 26 2.60 2.60 2.08 5.20 6.29 0.59 1.79 2.16 2.91 6.30 A++
26 35 2.31 3.09 2.08 5.40 6.29 0.59 1.83 2.16 2.95 6.30 A++
26 52 1.80 3.60 2.08 5.40 6.34 0.59 1.77 2.16 3.05 6.30 A++
35 35 2.70 2.70 2.08 5.40 6.29 0.59 1.79 2.16 3.01 6.30 A++
COMBINATIONS RATED POWER (kW) HEATING POWER (kW) INPUT POWER (kW)COP
(W/W)SCOP ENERGY CLASS COP -7
1x2
UNIT A
UNIT B
UNIT A
UNIT B
MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUMRATED
CAPACITY
20 20 2.50 2.50 2.20 5.00 5.94 0.50 1.30 1.85 3.85 4.00 A+ 3.19
20 26 2.32 2.98 2.20 5.30 6.05 0.50 1.39 1.85 3.81 4.00 A+ 3.16
20 35 2.03 3.47 2.20 5.50 6.66 0.50 1.48 1.85 3.71 4.00 A+ 3.07
20 52 1.57 4.07 2.20 5.60 6.71 0.50 1.47 1.85 3.81 4.00 A+ 3.16
26 26 2.75 2.75 2.20 5.50 6.66 0.50 1.48 1.85 3.71 4.00 A+ 3.07
26 35 2.40 3.20 2.20 5.60 6.66 0.50 1.49 1.85 3.75 4.00 A+ 3.11
26 52 1.87 3.73 2.20 5.60 6.71 0.50 1.47 1.85 3.81 4.00 A+ 3.16
35 35 2.80 2.80 2.20 5.60 6.66 0.50 1.49 1.85 3.75 4.00 A+ 3.11
BUSINESS GROUP
60
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
KAM3-62 DN7
20 20+20 20+20+20
26 20+26 20+20+26
35 20+35 20+20+35
52 20+52 20+26+26
26+26 20+26+35
26+35 26+26+26
26+52 26+26+35
35+35
KAM3-78 DN7
20 20+20 20+20+20
26 20+26 20+20+26
35 20+35 20+20+35
52 20+52 20+20+52
26+26 20+26+26
26+35 20+26+35
26+52 20+26+52
35+35 20+35+35
35+52 26+26+26
26+26+35
26+35+35
35+35+35
x1
x1
x2
x2
x3
x3
COMBINED SYSTEMS R-410A MULTISYSTEM
RESIDENTIAL RANGE COMBINED SYSTEMS
61
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
COMBINATIONS RATED POWER (kW) COOLING CAPACITY (kW) INPUT POWER (kW)EER
(W/W)SEER ENERGY CLASS
1x3
UNIT A UNIT B UNIT C UNIT A UNIT B UNIT C MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY
20 20 20 2.03 2.03 2.03 2.44 6.10 7.20 0.68 1.90 2.38 3.21 6.10 A++
20 20 26 1.92 1.92 2.47 2.44 6.30 7.26 0.68 1.96 2.38 3.22 6.10 A++
20 20 35 1.70 1.70 2.91 2.44 6.30 7.32 0.68 1.94 2.38 3.24 6.10 A++
20 26 26 1.76 2.27 2.27 2.44 6.30 7.32 0.68 1.94 2.38 3.24 6.10 A++
20 26 35 1.58 2.03 2.70 2.44 6.30 7.32 0.68 1.94 2.38 3.24 6.10 A++
26 26 26 2.10 2.10 2.10 2.44 6.30 7.32 0.68 1.94 2.38 3.24 6.10 A++
26 26 35 1.89 1.89 2.52 2.44 6.30 7.32 0.68 1.94 2.38 3.24 6.10 A++
COMBINATIONS RATED POWER (kW) COOLING CAPACITY (kW) INPUT POWER (kW)EER
(W/W)SEER ENERGY CLASS
1x3
UNIT A UNIT B UNIT C UNIT A UNIT B UNIT C MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY
20 20 20 2.43 2.43 2.43 2.77 7.30 8.69 0.76 2.27 2.93 3.21 6.60 A++
20 20 26 2.25 2.25 2.90 2.77 7.40 8.69 0.76 2.31 2.93 3.21 6.60 A++
20 20 35 2.13 2.13 3.65 2.77 7.90 8.69 0.76 2.46 2.93 3.21 6.60 A++
20 20 52 1.73 1.73 4.44 2.77 7.90 8.69 0.76 2.44 2.93 3.24 6.60 A++
20 26 26 2.13 2.74 2.74 2.77 7.60 8.69 0.76 2.37 2.93 3.21 6.60 A++
20 26 35 1.98 2.54 3.39 2.77 7.90 8.69 0.76 2.46 2.93 3.21 6.60 A++
20 26 52 1.63 2.09 4.18 2.77 7.90 8.69 0.76 2.44 2.93 3.24 6.60 A++
20 35 35 1.78 3.06 3.06 2.77 7.90 8.69 0.76 2.45 2.93 3.23 6.60 A++
26 26 26 2.63 2.63 2.63 2.77 7.90 8.69 0.76 2.46 2.93 3.21 6.60 A++
26 26 35 2.37 2.37 3.16 2.77 7.90 8.69 0.76 2.45 2.93 3.23 6.60 A++
26 35 35 2.15 2.87 2.87 2.77 7.90 8.69 0.76 2.44 2.93 3.24 6.60 A++
35 35 35 2.63 2.63 2.63 2.77 7.90 8.69 0.76 2.44 2.93 3.24 6.60 A++
COMBINATIONS RATED POWER (kW) HEATING POWER (kW) INPUT POWER (kW)COP
(W/W)SCOP
ENERGY CLASS
COP -7
1x3
UNIT A UNIT B UNIT C UNIT A UNIT B UNIT C MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUMRATED
CAPACITY
20 20 20 2.20 2.20 2.20 2.64 6.60 7.79 0.64 1.78 2.22 3.71 4.00 A+ 2.90
20 20 26 2.02 2.02 2.60 2.64 6.65 7.79 0.64 1.79 2.22 3.71 4.00 A+ 2.90
20 20 35 1.80 1.80 3.09 2.64 6.70 7.92 0.64 1.81 2.22 3.71 4.00 A+ 2.95
20 26 26 1.88 2.41 2.41 2.64 6.70 7.92 0.64 1.81 2.22 3.71 4.00 A+ 2.95
20 26 35 1.68 2.15 2.87 2.64 6.70 7.92 0.64 1.81 2.22 3.71 4.00 A+ 2.95
26 26 26 2.23 2.23 2.23 2.64 6.70 7.92 0.64 1.81 2.22 3.71 4.00 A+ 2.95
26 26 35 2.01 2.01 2.68 2.64 6.70 7.92 0.64 1.81 2.22 3.71 4.00 A+ 2.95
COMBINATIONS RATED POWER (kW) HEATING POWER (kW) INPUT POWER (kW)COP
(W/W)SCOP
ENERGY CLASS
COP -7
1x3
UNIT A UNIT B UNIT C UNIT A UNIT B UNIT C MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY
20 20 20 2.27 2.27 2.27 2.87 6.80 9.02 0.70 1.88 2.70 3.61 4.00 A+ 2.99
20 20 26 2.13 2.13 2.74 2.87 7.00 9.02 0.70 1.94 2.70 3.61 4.00 A+ 2.99
20 20 35 2.13 2.13 3.65 2.87 7.90 9.02 0.70 2.19 2.70 3.61 4.00 A+ 2.99
20 20 52 1.82 1.82 4.67 2.87 8.30 9.02 0.70 2.27 2.70 3.65 4.00 A+ 3.02
20 26 26 2.21 2.84 2.84 2.87 7.90 9.02 0.70 2.19 2.70 3.61 4.00 A+ 2.99
20 26 35 2.05 2.64 3.51 2.87 8.20 9.02 0.70 2.27 2.70 3.61 4.00 A+ 2.99
20 26 52 1.71 2.20 4.39 2.87 8.30 9.02 0.70 2.27 2.70 3.65 4.00 A+ 3.02
20 35 35 1.87 3.21 3.21 2.87 8.30 9.02 0.70 2.29 2.70 3.62 4.00 A+ 3.00
26 26 26 2.73 2.73 2.73 2.87 8.20 9.02 0.70 2.27 2.70 3.61 4.00 A+ 2.99
26 26 35 2.49 2.49 3.32 2.87 8.30 9.02 0.70 2.29 2.70 3.62 4.00 A+ 3.00
26 35 35 2.26 3.02 3.02 2.87 8.30 9.02 0.70 2.27 2.70 3.65 4.00 A+ 3.02
35 35 35 2.77 2.77 2.77 2.87 8.30 9.02 0.70 2.27 2.70 3.65 4.00 A+ 3.02
BUSINESS GROUP
62
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
KAM4-80 DN7
20 20+20 20+20+20 20+20+20+20
26 20+26 20+20+26 20+20+20+26
35 20+35 20+20+35 20+20+20+35
52 20+52 20+20+52 20+20+20+52
71 20+71 20+20+71 20+20+26+26
26+26 20+26+26 20+20+26+35
26+35 20+26+35 20+20+35+35
26+52 20+26+52 20+26+26+26
26+71 20+35+35 20+26+26+35
35+35 20+35+52 20+26+35+35
35+52 26+26+26 26+26+26+26
35+71 26+26+35 26+26+26+35
52+52 26+26+52
26+35+35
26+35+52
35+35+35
x1 x2 x3 x4
COMBINED SYSTEMS R-410A MULTISYSTEM
RESIDENTIAL RANGE COMBINED SYSTEMS
63
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
1x4
UNIT AUNIT
BUNIT
CUNIT
UNIT A
UNIT B
UNIT C
UNIT D
MIN. RATED MAX. MIN. RATED MAX. RATED CAPACITY
20 20 20 20 2.05 2.05 2.05 2.05 3.04 8.21 9.93 0.84 2.47 3.09 3.32 6.8 A++
20 20 20 26 1.92 1.92 1.92 2.46 3.04 8.21 9.93 0.84 2.47 3.09 3.32 6.8 A++
20 20 20 35 1.74 1.74 1.74 2.99 3.04 8.21 9.93 0.84 2.47 3.09 3.32 6.8 A++
20 20 20 52 1.47 1.47 1.47 3.79 3.04 8.21 9.93 0.84 2.50 3.09 3.28 6.8 A++
20 20 26 26 1.80 1.80 2.31 2.31 3.04 8.21 9.93 0.84 2.47 3.09 3.32 6.8 A++
20 20 26 35 1.64 1.64 2.11 2.81 3.04 8.21 9.93 0.84 2.49 3.09 3.30 6.8 A++
20 20 35 35 1.51 1.51 2.59 2.59 3.04 8.21 9.93 0.84 2.50 3.09 3.29 6.8 A++
20 26 26 26 1.69 2.17 2.17 2.17 3.04 8.21 9.93 0.84 2.48 3.09 3.31 6.8 A++
20 26 26 35 1.55 2.00 2.00 2.66 3.04 8.21 9.93 0.84 2.50 3.09 3.29 6.8 A++
20 26 35 35 1.44 1.85 2.46 2.46 3.04 8.21 9.93 0.84 2.50 3.09 3.28 6.8 A++
26 26 26 26 2.05 2.05 2.05 2.05 3.04 8.21 9.93 0.84 2.50 3.09 3.29 6.8 A++
26 26 26 35 1.89 1.89 1.89 2.53 3.04 8.21 9.93 0.84 2.50 3.09 3.28 6.8 A++
1x4
UNIT AUNIT
BUNIT
CUNIT
UNIT A
UNIT B
UNIT C
UNIT D
MIN. RATED MAX. MIN. RATED MAX. RATED CAPACITY
20 20 20 20 2.20 2.20 2.20 2.20 3.26 8.80 10.65 0.83 2.44 3.05 3.61 4.0 A++ 2.99
20 20 20 26 2.08 2.08 2.08 2.67 3.26 8.90 10.65 0.83 2.47 3.05 3.61 4.0 A++ 2.99
20 20 20 35 1.91 1.91 1.91 3.27 3.26 9.00 10.65 0.83 2.49 3.05 3.61 4.0 A++ 2.99
20 20 20 52 1.63 1.63 1.63 4.20 3.26 9.10 10.65 0.83 2.52 3.05 3.61 4.0 A++ 2.99
20 20 26 26 1.95 1.95 2.50 2.50 3.26 8.90 10.65 0.83 2.47 3.05 3.61 4.0 A++ 2.99
20 20 26 35 1.80 1.80 2.31 3.09 3.26 9.00 10.65 0.83 2.49 3.05 3.61 4.0 A++ 2.99
20 20 35 35 1.68 1.68 2.87 2.87 3.26 9.10 10.65 0.83 2.52 3.05 3.61 4.0 A++ 2.99
20 26 26 26 1.83 2.36 2.36 2.36 3.26 8.90 10.65 0.83 2.47 3.05 3.61 4.0 A++ 2.99
20 26 26 35 1.70 2.19 2.19 2.92 3.26 9.00 10.65 0.83 2.49 3.05 3.61 4.0 A++ 2.99
20 26 35 35 1.59 2.05 2.73 2.73 3.26 9.10 10.65 0.83 2.52 3.05 3.61 4.0 A++ 2.99
26 26 26 26 2.23 2.23 2.23 2.23 3.26 8.90 10.65 0.83 2.47 3.05 3.61 4.0 A++ 2.99
26 26 26 35 2.10 2.10 2.10 2.80 3.26 9.10 10.65 0.83 2.52 3.05 3.61 4.0 A++ 2.99
RATED CAPACITY (KW)
RATED CAPACITY (KW)
COOLING CAPACITY (KW)
HEATING CAPACITY (KW)
EERW/W
COPW/W
SEER
SCOP COP -7
ENERGY CLASS
ENERGY CLASS
INPUT POWER (kW)
INPUT POWER (kW)
COMBINATIONS
COMBINATIONS
BUSINESS GROUP
64
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
KAM4-105 DN7
20 20 +20 20 +20 +20 20 +20 +20 +20
26 20 +26 20 +20 +26 20 +20 +20 +26
35 20 +35 20 +20 +35 20 +20 +20 +35
52 20 +52 20 +20 +52 20 +20 +20 +52
71 20 +71 20 +20 +71 20 +20 +20 +71
26+26 20 +26 +26 20 +20 +26 +26
26+35 20 +26 +35 20 +20 +26 +35
26+52 20 +26 +52 20 +20 +26 +52
26+71 20 +26 +71 20 +20 +26 +71
35+35 20 +35 +35 20 +20 +35 +35
35+52 20 +35 +52 20 +20 +35 +52
35+71 20 +35 +71 20 +20 +52 +52
52+52 20 +52 +52 20 +26+26+26
26+26+26 20 +26+26+35
26+26+35 20 +26+26+52
26+26+52 20 +26+26+71
26+35+35 20 +26+35+35
26+35+52 20 +26+35+52
26+35+71 20 +26+52+52
26+52+52 20 +35+35+35
35+35+35 20 +35+35+52
35+35+52 26+26+26+26
35+35+71 26+26+26+35
35+52+52 26+26+26+52
26+26+35+35
26+26+35+52
26+35+35+35
26+35+35+52
35+35+35+35
x1 x2 x3 x4
COMBINED SYSTEMS R-410A MULTISYSTEM
RESIDENTIAL RANGE COMBINED SYSTEMS
65
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
COMBINATIONS RATED CAPACITY (KW); COOLING CAPACITY (KW) INPUT POWER (KW)EER
(W/W)SEER
ENERGY CLASS
UNIT A
UNIT B
UNIT C
UNIT D
UNIT A
UNIT B
UNIT C
UNIT D
MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY
1x4
20 20 20 20 2.05 2.05 2.05 2.05 3.71 8.20 10.60 0.89 2.30 3.30 3.56 7.6 A++
20 20 20 26 1.98 1.98 1.98 2.55 3.71 8.50 11.66 0.89 2.50 3.47 3.40 7.6 A++
20 20 20 35 2.02 2.02 2.02 3.45 3.71 9.50 12.72 0.89 2.88 3.63 3.30 7.6 A++
20 20 20 52 1.88 1.88 1.88 4.85 3.71 10.50 13.78 0.89 3.27 4.29 3.21 7.4 A++
20 20 20 71 1.65 1.65 1.65 5.65 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.4 A++
20 20 26 26 1.97 1.97 2.53 2.53 3.71 9.00 12.72 0.89 2.73 3.63 3.30 7.6 A++
20 20 26 35 2.00 2.00 2.57 3.43 3.71 10.00 13.25 0.89 3.12 3.96 3.21 7.6 A++
20 20 26 52 1.79 1.79 2.30 4.61 3.71 10.50 13.78 0.89 3.27 4.29 3.21 7.6 A++
20 20 26 71 1.58 1.58 2.03 5.41 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++
20 20 35 35 1.93 1.93 3.32 3.32 3.71 10.50 13.78 0.89 3.27 4.29 3.21 7.6 A++
20 20 35 52 1.67 1.67 2.86 4.30 3.71 10.50 13.78 0.89 3.27 4.29 3.21 7.6 A++
20 20 52 52 1.47 1.47 3.78 3.78 3.71 10.50 13.78 0.89 3.27 4.29 3.21 7.4 A++
20 26 26 26 1.96 2.51 2.51 2.51 3.71 9.50 13.25 0.89 2.94 3.80 3.23 7.6 A++
20 26 26 35 2.01 2.58 2.58 3.44 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++
20 26 26 52 1.73 2.22 2.22 4.44 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++
20 26 26 71 1.51 1.95 1.95 5.19 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++
20 26 35 35 1.86 2.39 3.18 3.18 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++
20 26 35 52 1.61 2.07 2.77 4.15 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++
20 26 52 52 1.43 1.83 3.67 3.67 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++
20 35 35 35 1.73 2.96 2.96 2.96 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++
20 35 35 52 1.51 2.60 2.60 3.89 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.4 A++
26 26 26 26 2.65 2.65 2.65 2.65 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++
26 26 26 35 2.45 2.45 2.45 3.26 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++
26 26 26 52 2.12 2.12 2.12 4.24 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++
26 26 35 35 2.27 2.27 3.03 3.03 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++
26 26 35 52 1.99 1.99 2.65 3.98 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++
26 35 35 35 2.12 2.83 2.83 2.83 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++
26 35 35 52 1.87 2.49 2.49 3.74 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.4 A++
35 35 35 35 2.65 2.65 2.65 2.65 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++
COMBINATIONS RATED CAPACITY (KW) HEATING CAPACITY (KW) POWER INPUT (KW)COP
(W/W)SCOP
ENERGY CLASS
COP -7
1x4
UNIT A
UNIT B
UNIT C
UNIT D
UNIT A
UNIT B
UNIT C
UNIT D
MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY
20 20 20 20 2.50 2.50 2.50 2.50 3.89 10.00 11.10 0.83 2.59 3.06 3.86 3.8 A 3.20
20 20 20 26 2.36 2.36 2.36 3.03 3.89 10.10 11.66 0.83 2.69 3.21 3.75 3.8 A 3.11
20 20 20 35 2.31 2.31 2.31 3.96 3.89 10.90 12.21 0.83 2.95 3.36 3.70 3.8 A 3.07
20 20 20 52 1.99 1.99 1.99 5.12 3.89 11.10 13.32 0.83 3.04 3.98 3.65 3.8 A 3.02
20 20 20 71 1.73 1.73 1.73 5.92 3.89 11.10 13.32 0.83 3.04 3.98 3.65 3.8 A 3.02
20 20 26 26 2.38 2.38 3.07 3.07 3.89 10.90 12.21 0.83 2.95 3.36 3.70 3.8 A 3.07
20 20 26 35 2.22 2.22 2.85 3.81 3.89 11.10 12.77 0.83 3.00 3.67 3.70 3.8 A 3.07
20 20 26 52 1.90 1.90 2.44 4.87 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01
20 20 26 71 1.65 1.65 2.13 5.67 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01
20 20 35 35 2.04 2.04 3.51 3.51 3.89 11.10 13.32 0.83 3.04 3.98 3.65 3.8 A 3.02
20 20 35 52 1.77 1.77 3.03 4.54 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01
20 20 52 52 1.55 1.55 4.00 4.00 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01
20 26 26 26 2.29 2.94 2.94 2.94 3.89 11.10 12.77 0.83 3.00 3.52 3.70 3.8 A 3.07
20 26 26 35 2.10 2.70 2.70 3.60 3.89 11.10 13.32 0.83 3.05 3.98 3.64 3.8 A 3.02
20 26 26 52 1.81 2.32 2.32 4.65 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01
20 26 26 71 1.59 2.04 2.04 5.44 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01
20 26 35 35 1.94 2.50 3.33 3.33 3.89 11.10 13.32 0.83 3.05 3.98 3.64 3.8 A 3.02
20 26 35 52 1.69 2.17 2.90 4.34 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01
20 26 52 52 1.49 1.92 3.84 3.84 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01
20 35 35 35 1.81 3.10 3.10 3.10 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01
20 35 35 52 1.59 2.72 2.72 4.08 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01
26 26 26 26 2.78 2.78 2.78 2.78 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01
26 26 26 35 2.56 2.56 2.56 3.42 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01
26 26 26 52 2.22 2.22 2.22 4.44 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01
26 26 35 35 2.38 2.38 3.17 3.17 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01
26 26 35 52 2.08 2.08 2.78 4.16 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01
26 35 35 35 2.22 2.96 2.96 2.96 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01
26 35 35 52 1.96 2.61 2.61 3.92 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01
35 35 35 35 2.78 2.78 2.78 2.78 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01
BUSINESS GROUP
66
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
COMBINED SYSTEMSKAM5-120 DN7
20 20+20 20+20+20 20+20+20+20 20+20+20+20+20
26 20+26 20+20+26 20+20+20+26 20+20+20+20+26
35 20+35 20+20+35 20+20+20+35 20+20+20+20+35
52 20+52 20+20+52 20+20+20+52 20+20+20+20+52
71 20+71 20+20+71 20+20+20+71 20+20+20+20+71
26+26 20+26+26 20+20+26+26 20+20+20+26+26
26+35 20+26+35 20+20+26+35 20+20+20+26+35
26+52 20+26+52 20+20+26+52 20+20+20+26+52
26+71 20+26+71 20+20+26+71 20+20+20+26+71
35+35 20+35+35 20+20+35+35 20+20+20+35+35
35+52 20+35+52 20+20+35+52 20+20+20+35+52
35+71 20+35+71 20+20+35+71 20+20+20+35+71
52+52 20+52+52 20+20+52+52 20+20+20+52+52
52+71 26+26+26 20+20+52+71 20+20+26+26+26
71+71 26+26+35 20+26+26+26 20+20+26+26+35
26+26+52 20+26+26+35 20+20+26+26+52
26+26+71 20+26+26+52 20+20+26+26+71
26+35+35 20+26+26+71 20+20+26+35+35
26+35+52 20+26+35+35 20+20+26+35+52
26+35+71 20+26+35+52 20+20+26+52+52
26+52+52 20+26+35+71 20+20+35+35+35
35+35+35 20+26+52+52 20+20+35+35+52
35+35+52 20+26+52+71 20+26+26+26+26
35+35+71 20+35+35+35 20+26+26+26+35
35+52+52 20+35+35+52 20+26+26+26+52
35+52+71 20+35+52+52 20+26+26+26+71
52+52+52 20+35+52+71 20+26+26+35+35
26+26+26+26 20+26+26+35+52
26+26+26+35 20+26+35+35+35
26+26+26+52 20+26+35+35+52
26+26+26+71 20+35+35+35+35
26+26+35+35 26+26+26+26+26
26+26+35+52 26+26+26+26+35
26+26+35+71 26+26+26+26+52
26+26+52+52 26+26+26+35+35
26+35+35+35 26+26+26+35+52
26+35+35+52 26+26+35+35+35
26+35+35+71 26+35+35+35+35
26+35+52+52
35+35+35+35
35+35+35+52
x1 x2 x3 x4 x5
R-410A MULTISYSTEM
RESIDENTIAL RANGE COMBINED SYSTEMS
67
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
COMBINATIONS RATED CAPACITY (kW)COOLING CAPACITY
(kW)INPUT
POWER (kW)EER
(W/W)SEER
(W/W)ENERGY CLASS
5x
UNIT A UNIT B UNIT C UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E MIN. RAT. MAX. MIN. RAT. MAX.RATED
CAPACITY
20 20 20 20 20 2.10 2.10 2.10 2.10 2.10 4.18 10.50 14.00 1.01 3.09 4.55 3.40 7.7 A++20 20 20 20 26 2.08 2.08 2.08 2.08 2.68 4.18 11.00 14.00 1.01 3.24 4.55 3.40 7.7 A++20 20 20 20 35 2.01 2.01 2.01 2.01 3.45 4.18 11.50 14.00 1.01 3.42 4.55 3.37 7.7 A++20 20 20 20 52 1.87 1.87 1.87 1.87 4.81 4.18 12.30 14.00 1.01 3.73 4.55 3.30 7.7 A++20 20 20 20 71 1.66 1.66 1.66 1.66 5.68 4.18 12.30 14.00 1.01 3.76 4.55 3.27 7.7 A++20 20 20 26 26 2.06 2.06 2.06 2.65 2.65 4.18 11.50 14.00 1.01 3.42 4.55 3.37 7.7 A++20 20 20 26 35 2.00 2.00 2.00 2.57 3.43 4.18 12.00 14.00 1.01 3.57 4.55 3.37 7.7 A++20 20 20 26 52 1.79 1.79 1.79 2.31 4.61 4.18 12.30 14.00 1.01 3.73 4.55 3.30 7.7 A++20 20 20 26 71 1.59 1.59 1.59 2.05 5.47 4.18 12.30 14.00 1.01 3.76 4.55 3.27 7.7 A++20 20 20 35 35 1.91 1.91 1.91 3.28 3.28 4.18 12.30 14.00 1.01 3.69 4.55 3.33 7.7 A++20 20 20 35 52 1.69 1.69 1.69 2.89 4.34 4.18 12.30 14.00 1.01 3.75 4.55 3.28 7.7 A++20 20 20 35 71 1.51 1.51 1.51 2.59 5.18 4.18 12.30 14.00 1.01 3.80 4.55 3.23 7.7 A++20 20 20 52 52 1.51 1.51 1.51 3.88 3.88 4.18 12.30 14.00 1.01 3.80 4.55 3.23 7.7 A++20 20 26 26 26 2.05 2.05 2.63 2.63 2.63 4.18 12.00 14.00 1.01 3.57 4.55 3.37 7.7 A++20 20 26 26 35 1.96 1.96 2.52 2.52 3.35 4.18 12.30 14.00 1.01 3.69 4.55 3.33 7.7 A++20 20 26 26 52 1.72 1.72 2.21 2.21 4.43 4.18 12.30 14.00 1.01 3.75 4.55 3.28 7.7 A++20 20 26 26 71 1.54 1.54 1.98 1.98 5.27 4.18 12.30 14.00 1.01 3.80 4.55 3.23 7.7 A++20 20 26 35 35 1.83 1.83 2.36 3.14 3.14 4.18 12.30 14.00 1.01 3.73 4.55 3.30 7.7 A++20 20 26 35 52 1.62 1.62 2.09 2.78 4.18 4.18 12.30 14.00 1.01 3.76 4.55 3.27 7.7 A++20 20 26 52 52 1.46 1.46 1.88 3.75 3.75 4.18 12.30 14.00 1.01 3.84 4.55 3.20 7.7 A++20 20 35 35 35 1.72 1.72 2.95 2.95 2.95 4.18 12.30 14.00 1.01 3.73 4.55 3.30 7.7 A++20 20 35 35 52 1.54 1.54 2.64 2.64 3.95 4.18 12.30 14.00 1.01 3.76 4.55 3.27 7.7 A++20 26 26 26 26 2.00 2.57 2.57 2.57 2.57 4.18 12.30 14.00 1.01 3.69 4.55 3.33 7.7 A++20 26 26 26 35 1.87 2.41 2.41 2.41 3.21 4.18 12.30 14.00 1.01 3.73 4.55 3.30 7.7 A++20 26 26 26 52 1.66 2.13 2.13 2.13 4.26 4.18 12.30 14.00 1.01 3.76 4.55 3.27 7.7 A++20 26 26 26 71 1.48 1.91 1.91 1.91 5.09 4.18 12.30 14.00 1.01 3.80 4.55 3.23 7.7 A++20 26 26 35 35 1.76 2.26 2.26 3.01 3.01 4.18 12.30 14.00 1.01 3.73 4.55 3.30 7.7 A++20 26 26 35 52 1.57 2.01 2.01 2.68 4.03 4.18 12.30 14.00 1.01 3.76 4.55 3.27 7.7 A++20 26 35 35 35 1.66 2.13 2.84 2.84 2.84 4.18 12.30 14.00 1.01 3.75 4.55 3.28 7.7 A++20 26 35 35 52 1.48 1.91 2.54 2.54 3.82 4.18 12.30 14.00 1.01 3.80 4.55 3.23 7.7 A++20 35 35 35 35 1.57 2.68 2.68 2.68 2.68 4.18 12.30 14.00 1.01 3.75 4.55 3.28 7.7 A++26 26 26 26 26 2.46 2.46 2.46 2.46 2.46 4.18 12.30 14.00 1.01 3.73 4.55 3.30 7.7 A++26 26 26 26 35 2.31 2.31 2.31 2.31 3.08 4.18 12.30 14.00 1.01 3.73 4.55 3.30 7.7 A++26 26 26 26 52 2.05 2.05 2.05 2.05 4.10 4.18 12.30 14.00 1.01 3.76 4.55 3.27 7.7 A++26 26 26 35 35 2.17 2.17 2.17 2.89 2.89 4.18 12.30 14.00 1.01 3.75 4.55 3.28 7.7 A++26 26 26 35 52 1.94 1.94 1.94 2.59 3.88 4.18 12.30 14.00 1.01 3.80 4.55 3.23 7.7 A++26 26 35 35 35 2.05 2.05 2.73 2.73 2.73 4.18 12.30 14.00 1.01 3.75 4.55 3.28 7.7 A++26 35 35 35 35 1.94 2.59 2.59 2.59 2.59 4.18 12.30 14.00 1.01 3.76 4.55 3.27 7.7 A++
COMBINATIONS RATED CAPACITY (kW)HEATING
CAPACITY (kW)INPUT
POWER (kW)COP
(W/W)SCOP
ENERGY CLASS
COP -7
5X1
UNIT A UNIT B UNIT C UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E MIN. RAT. MAX. MIN. RAT. MAX.RATED
CAPACITY
20 20 20 20 20 2.46 2.46 2.46 2.46 2.46 4.18 12.30 14.94 0.91 3.40 4.21 3.62 3.7 A 2.9420 20 20 20 26 2.33 2.33 2.33 2.33 2.99 4.18 12.30 14.94 0.91 3.40 4.21 3.62 3.8 A 2.9420 20 20 20 35 2.15 2.15 2.15 2.15 3.69 4.18 12.30 14.94 0.91 3.40 4.21 3.62 3.8 A 2.9420 20 20 20 52 1.87 1.87 1.87 1.87 4.81 4.18 12.30 14.94 0.91 3.37 4.21 3.65 3.8 A 2.9420 20 20 20 71 1.66 1.66 1.66 1.66 5.68 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.6 A 2.9420 20 20 26 26 2.21 2.21 2.21 2.84 2.84 4.18 12.30 14.94 0.91 3.40 4.21 3.62 3.8 A 2.9420 20 20 26 35 2.05 2.05 2.05 2.64 3.51 4.18 12.30 14.94 0.91 3.40 4.21 3.62 3.8 A 2.9420 20 20 26 52 1.79 1.79 1.79 2.31 4.61 4.18 12.30 14.94 0.91 3.32 4.21 3.71 3.8 A 2.9420 20 20 26 71 1.59 1.59 1.59 2.05 5.47 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.8 A 2.9420 20 20 35 35 1.91 1.91 1.91 3.28 3.28 4.18 12.30 14.94 0.91 3.40 4.21 3.62 3.8 A 2.9420 20 20 35 52 1.69 1.69 1.69 2.89 4.34 4.18 12.30 14.94 0.91 3.32 4.21 3.71 3.6 A 2.9420 20 20 35 71 1.51 1.51 1.51 2.59 5.18 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.5 A 2.9420 20 20 52 52 1.51 1.51 1.51 3.88 3.88 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.5 A 2.9420 20 26 26 26 2.10 2.10 2.70 2.70 2.70 4.18 12.30 14.94 0.91 3.40 4.21 3.62 3.8 A 2.9420 20 26 26 35 1.96 1.96 2.52 2.52 3.35 4.18 12.30 14.94 0.91 3.40 4.21 3.62 3.8 A 2.9420 20 26 26 52 1.72 1.72 2.21 2.21 4.43 4.18 12.30 14.94 0.91 3.32 4.21 3.71 3.8 A 2.9420 20 26 26 71 1.54 1.54 1.98 1.98 5.27 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.5 A 2.9420 20 26 35 35 1.83 1.83 2.36 3.14 3.14 4.18 12.30 14.94 0.91 3.37 4.21 3.65 3.6 A 2.9420 20 26 35 52 1.62 1.62 2.09 2.78 4.18 4.18 12.30 14.94 0.91 3.37 4.21 3.65 3.6 A 2.9420 20 26 52 52 1.46 1.46 1.88 3.75 3.75 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.4 A 2.9420 20 35 35 35 1.72 1.72 2.95 2.95 2.95 4.18 12.30 14.94 0.91 3.37 4.21 3.65 3.6 A 2.9420 20 35 35 52 1.54 1.54 2.64 2.64 3.95 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.6 A 2.9420 26 26 26 26 2.00 2.57 2.57 2.57 2.57 4.18 12.30 14.94 0.91 3.40 4.21 3.62 3.8 A 2.9420 26 26 26 35 1.87 2.41 2.41 2.41 3.21 4.18 12.30 14.94 0.91 3.37 4.21 3.65 3.8 A 2.9420 26 26 26 52 1.66 2.13 2.13 2.13 4.26 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.8 A 2.9420 26 26 26 71 1.48 1.91 1.91 1.91 5.09 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.5 A 2.9420 26 26 35 35 1.76 2.26 2.26 3.01 3.01 4.18 12.30 14.94 0.91 3.37 4.21 3.65 3.8 A 2.9420 26 26 35 52 1.57 2.01 2.01 2.68 4.03 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.6 A 2.9420 26 35 35 35 1.66 2.13 2.84 2.84 2.84 4.18 12.30 14.94 0.91 3.32 4.21 3.71 3.6 A 2.9420 26 35 35 52 1.48 1.91 2.54 2.54 3.82 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.4 A 2.9420 35 35 35 35 1.57 2.68 2.68 2.68 2.68 4.18 12.30 14.94 0.91 3.32 4.21 3.71 3.6 A 2.9426 26 26 26 26 2.46 2.46 2.46 2.46 2.46 4.18 12.30 14.94 0.91 3.37 4.21 3.65 3.8 A 2.9426 26 26 26 35 2.31 2.31 2.31 2.31 3.08 4.18 12.30 14.94 0.91 3.37 4.21 3.65 3.8 A 2.9426 26 26 26 52 2.05 2.05 2.05 2.05 4.10 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.5 A 2.9426 26 26 35 35 2.17 2.17 2.17 2.89 2.89 4.18 12.30 14.94 0.91 3.32 4.21 3.71 3.6 A 2.9426 26 26 35 52 1.94 1.94 1.94 2.59 3.88 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.5 A 2.9426 26 35 35 35 2.05 2.05 2.73 2.73 2.73 4.18 12.30 14.94 0.91 3.32 4.21 3.71 3.6 A 2.9426 35 35 35 35 1.94 2.59 2.59 2.59 2.59 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.5 A 2.94
BUSINESS GROUP
68
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
*Sound pressure in “Silence” mode.
AUREA II R-32 MULTISYSTEM
TECHNICAL SPECIFICATIONS
MODEL KAY-S 26 DR7 KAY-S 35 DR7 KAY-S 52 DR7 KAY-S 71 DR7
Cooling capacity kW 2.78 3.66 5.28 7.33
Cooling capacity Kcal/h 2268 3024 4536 6300
Heating capacity kW 2.93 3.81 5.57 7.62
Heating capacity Kcal/h 2520 3276 4788 6552
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
Airflow m3/h 515/459/337 515/459/337 750/505/420 1050/750/560
Sound pressure* dB (A) 21 23 21 26
Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8")
Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") ø15.9(5/8")
Width/Height/Depth mm 802/297/189 802/297/189 965/319/215 1080/335/226
Net weight Kg 8 8 9 12
Power wiring mm2 From outdoor From outdoor From outdoor From outdoor
Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5
NEW
INDOOR UNITSRESIDENTIAL RANGE
69
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
ERP
BMS AND SOFTWARE
CONTROLS
K01-WIFI
GENERAL CHARACTERISTICS
AUREA II, the medium category range of KAYSUN UK, is characterised by its versatile nature: it can run on R-410A or R-32 refrigerant. In addition to a simple and elegant design, it incorporates all of KAYSUN’s most advanced characteristics and technologies.
• Optional WIFI control adding K03 WIFI USB.
• Mono-Multi compatible.
• White translucent smart DISPLAY with information on the equipment and alarm systems status.
• The display and buzzer have a switch-off option which can be activated if they annoy the user.
• KID-02 S controller included to control unit's work parameters and change its configuration.
• Louvres position memory.
• Drainage pipe connection from left or right option.
WIFI CONTROL (OPTIONAL)+
21 dB SOUND PRESSURE+
COMPATIBLE WITH
MULTISYSTEM OUTDOOR UNITS
see pag. 72
K03 WIFI USB ACCESSORY
OPTIONAL WIFI
KID-02 SSTANDARD
PRICE LIST
MODEL STANDARD CONTROLLER PRICE SET £
KAY-S 26 DR7 KID-02 S £131
KAY-S 35 DR7 KID-02 S £139
KAY-S 52 DR7 KID-02 S £239
KAY-S 71 DR7 KID-02 S £277
ACCESSORIES
MODEL PRICE
K03 WIFI USB ACCESSORY £36
BUSINESS GROUP
70
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
MODEL KAM2-52 DR7 KAM3-78 DR7 KAM4-105 DR7 KAM5-120 DR7
Cooling capacity kW 5.28 7.91 10.55 12.31
Cooling capacity Kcal/h 4536 6804 9072 10584
Cooling input kW 1750 2470 3517 3800
Heating capacity kW 5.57 8.21 11140 12.60
Heating capacity Kcal/h 4788 7056 9576 10836
Heating input kW 1450 2350 2880 3300
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
Compressor type Rotary Rotary Rotary Rotary
Outdoor airflow m3/h 2200 2700 4000 3850
Sound pressure dB (A) 56 59 63 62
Refrigerant R-32 R-32 R-32 R-32
Additional refrigerant charge* gr 1300 1570 2100 2400
Pre-charge metres* m 15 22.5 30 37.5
Liquid pipe diameter mm (Inch) ø6.35 (1/4") x 2 ø6.35 (1/4") x 3 ø6.35 (1/4") x 4 ø6.35 (1/4") x 5
Gas pipe diameter mm (Inch) ø9.52 (3/8") x 2 ø9.52 (3/8") x 3 ø9.52 (3/8") x 3 + ø12.7 (1/2") x 1
ø9.52 (3/8") x 3 + ø12.7 (1/2") x 2
Max. piping length m 40 60 80 80
Piping max. length (1 indoor unit) m 25 30 35 35
Height difference between indoor and outdoor units
m 15 15 15 15
Height difference between indoor units m 10 10 10 10
Width/Height/Depth mm 800/554/333 845/702/363 946/810/410 946/810/410
Net weight Kg 36.0 53.0 68.8 73.3
Maximum number of indoor units 2 3 4 5
Power wiring mm2 (2+T)x2.5 (2+T)x4 (2+T)x6 (2+T)x6
Communication wiring mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5
OUTDOOR UNITS
TECHNICAL SPECIFICATIONS
R-32 MULTISYSTEM NEW
RESIDENTIAL RANGE OUTDOOR UNITS
71
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
ERP
KAYSUN UK MULTISYSTEM outdoor units, with their strong structure, provide greater output with less noise pollution.
QUIET+
STRONG +
PRICE LIST
MODEL PRICE
KAM2-52 DR7 £837
KAM3-78 DR7 £1,191
KAM4-105 DR7 £1,621
KAM5-120 DR7 £1,940
BUSINESS GROUP
72
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
KAM2-52 DR7
26 26+26
35 26+35
52 26+52
35+35
x1 x2
COMBINED SYSTEMS
KAM3-78 DR7
26 26+26 26+26+26
35 26+35 26+26+35
52 26+52 26+26+52
35+35 26+35+35
35+52 26+35+52
52+52 35+35+35
x1 x2 x3
R-32 MULTISYSTEM
RESIDENTIAL RANGE COMBINED SYSTEMS
73
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
COMBINATIONSRATED
CAPACITY (kW)COOLING
CAPACITY (kW)INPUT
POWER (kW)EER
(W/W)SEER ENERGY CLASS
1x2
UNIT A
UNIT B
UNIT A
UNIT B
MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY
26 26 2.64 2.64 2.11 5.28 6.44 0.54 1.63 2.04 3.23 6.6 A++
26 35 2.27 3.03 2.11 5.3 6.44 0.54 1.64 2.04 3.23 6.6 A++
26 52 1.8 3.6 2.11 5.4 6.49 0.54 1.65 2.04 3.27 6.6 A++
35 35 2.65 2.65 2.11 5.3 6.44 0.54 1.64 2.04 3.23 6.6 A++
COMBINATIONSRATED
CAPACITY (kW)HEATING
POWER (kW)INPUT
POWER (kW)COP
(W/W)SCOP
ENERGY CLASS
COP -7
1x2
UNIT A
UNIT B
UNIT A
UNIT B
MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUMRATED
CAPACITY
26 26 2.79 2.79 2.23 5.57 6.8 0.47 1.39 1.88 4.0 4.0 A+ 3.2
26 35 2.4 3.2 2.23 5.6 6.8 0.47 1.4 1.88 4.0 4.0 A+ 3.2
26 52 1.93 3.87 2.23 5.8 6.85 0.47 1.46 1.88 3.97 4.0 A+ 3.17
35 35 2.8 2.8 2.23 5.6 6.8 0.47 1.4 1.88 4.0 4.0 A+ 3.2
COMBINATIONSRATED
CAPACITY (kW)COOLING
CAPACITY (kW)INPUT
POWER (kW)EER
(W/W)SEER
ENERGY CLASS
1x3
UNIT A UNIT B UNIT C UNIT A UNIT B UNIT C MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY
26 26 26 2.63 2.63 2.63 2.77 7.9 8.69 0.74 2.39 2.9 3.3 6.7 A++
26 26 35 2.37 2.37 3.16 2.77 7.9 8.69 0.74 2.39 2.9 3.31 6.7 A++
26 26 52 1.98 1.98 3.95 2.77 7.9 8.69 0.74 2.39 2.9 3.31 6.7 A++
26 35 35 2.15 2.87 2.87 2.77 7.9 8.69 0.74 2.38 2.9 3.32 6.7 A++
26 35 52 1.82 2.43 3.65 2.77 7.9 8.69 0.74 2.38 2.9 3.32 6.7 A++
35 35 35 2.63 2.63 2.63 2.77 7.9 8.69 0.74 2.38 2.9 3.32 6.7 A++
COMBINATIONSRATED
CAPACITY (kW)HEATING
POWER (kW)INPUT
POWER (kW)COP
(W/W)SCOP
ENERGY CLASS
COP -7
1x3
UNIT A UNIT B UNIT C UNIT A UNIT B UNIT C MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY
26 26 26 2.73 2.73 2.73 2.87 8.2 9.02 0.68 2.20 2.62 3.73 4.0 A+ 3.13
26 26 35 2.49 2.49 3.32 2.87 8.3 9.02 0.68 2.22 2.62 3.74 4.0 A+ 3.14
26 26 52 2.08 2.08 4.15 2.87 8.3 9.02 0.68 2.22 2.62 3.74 4.0 A+ 3.14
26 35 35 2.26 3.02 3.02 2.87 8.3 9.02 0.68 2.21 2.62 3.76 4.0 A+ 3.16
26 35 52 1.92 2.56 3.83 2.87 8.3 9.02 0.68 2.22 2.62 3.74 4.0 A+ 3.14
35 35 35 2.77 2.77 2.77 2.87 8.3 9.02 0.68 2.21 2.62 3.76 4.0 A+ 3.16
BUSINESS GROUP
74
POWER RANGE
Go back to General Contents Go back to SUITE Index(Index)
COMBINED SYSTEMS
KAM4-105 DR7
26 26+26 26+26+26 26+26+26+26
35 26+35 26+26+35 26+26+26+35
52 26+52 26+26+52 26+26+26+52
70 26+70 26+26+70 26+26+35+35
35+35 26+35+35 26+26+35+52
35+52 26+35+52 26+35+35+35
35+70 26+35+70 26+35+35+52
52+52 26+52+52 35+35+35+35
35+35+35 35+35+35+52
35+35+52
35+35+70
35+52+52
KAM5-120 DR7
26 26+26 26+26+26 26+26+26+26 26+26+26+26+26
35 26+35 26+26+35 26+26+26+35 26+26+26+26+35
52 26+52 26+26+52 26+26+26+52 26+26+26+26+52
71 26+71 26+26+71 26+26+26+71 26+26+26+35+35
35+35 26+35+35 26+26+35+35 26+26+26+35+52
35+52 26+35+52 26+26+35+52 26+26+35+35+35
35+71 26+35+71 26+26+35+71 26+35+35+35+35
52+52 26+52+52 26+35+35+35 26+35+35+35+52
35+35+35 26+35+35+52 35+35+35+35+35
35+35+52 35+35+35+35
35+35+71 35+35+35+52
35+52+52
x1
x1
x2
x2
x3 x4
x4 x5x3
R-32 MULTISYSTEM
RESIDENTIAL RANGE COMBINED SYSTEMS
75
Design and Install for you
SU
ITE
R
ES
IDE
NTI
AL
Go back to General Contents Go back to SUITE Index(Index)
1x4
UNIT A UNIT B UNIT C UNIT UNIT A UNIT B UNIT C UNIT D MIN. RATED MAX. MIN. RATED MAX. RATED CAPACITY
26 26 26 26 2.63 2.63 2.63 2.63 3.68 10.5 13.65 0.95 3.5 4.27 3.0 6.5 A++
26 26 26 35 2.42 2.42 2.42 3.23 3.68 10.5 13.65 0.95 3.5 4.27 3.0 6.5 A++
26 26 26 52 2.1 2.1 2.1 4.2 3.68 10.5 13.65 0.95 3.5 4.27 3.0 6.5 A++
26 26 35 35 2.25 2.25 3 3 3.68 10.5 13.65 0.95 3.5 4.27 3.0 6.5 A++
26 26 35 52 1.97 1.97 2.63 3.94 3.68 10.5 13.65 0.95 3.5 4.27 3.0 6.5 A++
26 35 35 35 2.1 2.8 2.8 2.8 3.68 10.5 13.65 0.95 3.5 4.27 3.0 6.5 A++
26 35 35 52 1.85 2.47 2.47 3.71 3.68 10.5 13.65 0.95 3.5 4.27 3.0 6.5 A++
35 35 35 35 2.63 2.63 2.63 2.63 3.68 10.5 13.65 0.95 3.5 4.27 3.0 6.5 A++
35 35 35 52 2.33 2.33 2.33 3.5 3.68 10.5 13.65 0.95 3.5 4.27 3.0 6.5 A++
1x4
UNIT AUNIT
BUNIT
CUNIT
UNIT A
UNIT B
UNIT C
UNIT D
MIN. RATED MAX. MIN. RATED MAX. RATED CAPACITY
26 26 26 26 2.78 2.78 2.78 2.78 3.89 11.1 13.32 0.79 2.91 3.79 3.81 4.0 A 3.11
26 26 26 35 2.56 2.56 2.56 3.42 3.89 11.1 13.32 0.79 2.91 3.79 3.81 4.0 A 3.11
26 26 26 52 2.22 2.22 2.22 4.44 3.89 11.1 13.32 0.79 2.91 3.79 3.81 4.0 A 3.11
26 26 35 35 2.38 2.38 3.17 3.17 3.89 11.1 13.32 0.79 2.91 3.79 3.81 4.0 A 3.11
26 26 35 52 2.08 2.08 2.78 4.16 3.89 11.1 13.32 0.79 2.91 3.79 3.81 4.0 A 3.11
26 35 35 35 2.22 2.96 2.96 2.96 3.89 11.1 13.32 0.79 2.91 3.79 3.81 4.0 A 3.11
26 35 35 52 1.96 2.61 2.61 3.92 3.89 11.1 13.32 0.79 2.91 3.79 3.81 4.0 A 3.11
35 35 35 35 2.78 2.78 2.78 2.78 3.89 11.1 13.32 0.79 2.91 3.79 3.81 4.0 A 3.11
35 35 35 52 2.47 2.47 2.47 3.70 3.89 11.1 13.32 0.79 2.91 3.79 3.81 4.0 A 3.11
RATED CAPACITY (KW)
RATED CAPACITY (KW)
COOLING CAPACITY (KW)
HEATING CAPACITY (KW)
EERW/W
COPW/W
SEER
SCOP COP -7
ENERGY CLASS
ENERGY CLASS
INPUT POWER (kW)
INPUT POWER (kW)
COMBINATIONS
COMBINATIONS
COMBINATIONS RATED CAPACITY (kW)COOLING
CAPACITY (kW)INPUT
POWER (kW)EER
(W/W)SEER
(W/W)ENERGY CLASS
1x5
UNIT A UNIT B UNIT C UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E MIN. RAT. MAX. MIN. RAT. MAX.RATED
CAPACITY
26 26 26 26 26 2.46 2.46 2.46 2.46 2.46 4.18 12.3 14 1.11 4.1 4.55 3.0 6.8 A++
26 26 26 26 35 2.31 2.31 2.31 2.31 3.08 4.18 12.3 14 1.11 4.1 4.55 3.0 6.8 A++
26 26 26 26 52 2.05 2.05 2.05 2.05 4.1 4.18 12.3 14 1.11 4.09 4.55 3.01 6.8 A++
26 26 26 35 35 2.17 2.17 2.17 2.89 2.89 4.18 12.3 14 1.11 4.07 4.55 3.02 6.8 A++
26 26 26 35 52 1.94 1.94 1.94 2.59 3.88 4.18 12.3 14 1.11 4.09 4.55 3.01 6.8 A++
26 26 35 35 35 2.05 2.05 2.73 2.73 2.73 4.18 12.3 14 1.11 4.07 4.55 3.02 6.8 A++
26 35 35 35 35 1.94 2.59 2.59 2.59 2.59 4.18 12.3 14 1.11 4.09 4.55 3.01 6.8 A++
26 35 35 35 52 1.76 2.34 2.34 2.34 3.51 4.182 12.3 14 1.11 4.09 4.55 3.00 6.8 A++
35 35 35 35 35 2.46 2.46 2.46 2.46 2.46 4.182 12.3 14 1.11 4.09 4.55 3.00 6.8 A++
COMBINATIONS RATED CAPACITY (kW)HEATING
CAPACITY (kW)INPUT
POWER (kW)COP
(W/W)SCOP
ENERGY CLASS
COP -7
1x5
UNIT A UNIT B UNIT C UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E MIN. RAT. MAX. MIN. RAT. MAX.RATED
CAPACITY
26 26 26 26 26 2.46 2.46 2.46 2.46 2.46 4.18 12.3 14.94 0.9 3.32 4.14 3.71 4.0 A 3.01
26 26 26 26 35 2.31 2.31 2.31 2.31 3.08 4.18 12.3 14.94 0.9 3.32 4.14 3.71 4.0 A 3.01
26 26 26 26 52 2.05 2.05 2.05 2.05 4.1 4.18 12.3 14.94 0.9 3.23 4.14 3.81 3.5 A 3.11
26 26 26 35 35 2.17 2.17 2.17 2.89 2.89 4.18 12.3 14.94 0.9 3.26 4.14 3.77 3.8 A 3.07
26 26 26 35 52 1.94 1.94 1.94 2.59 3.88 4.18 12.3 14.94 0.9 3.23 4.14 3.81 3.5 A 3.11
26 26 35 35 35 2.05 2.05 2.73 2.73 2.73 4.18 12.3 14.94 0.9 3.3 4.14 3.77 3.8 A 3.07
26 35 35 35 35 1.94 2.59 2.59 2.59 2.59 4.18 12.3 14.94 0.9 3.2 4.14 3.81 3.5 A 3.11
26 35 35 35 52 1.84 1.84 2.46 2.46 3.69 4.182 12.3 14.94 0.9 3.2 4.14 3.81 3.8 A 3.11
35 35 35 35 35 2.46 2.46 2.46 2.46 2.46 4.182 12.3 14.94 0.9 3.2 4.14 3.81 3.5 A 3.11
77
Design and Install for you
INTRODUCTION TO THE PRODUCT RANGE ..............................................78
SETS ........................................................................................................... ..80
CASSETTE (600X600) ....................................................................... ..82
SUPERSLIM CASSETTE ..................................................................... ..84
CEILING/FLOOR ................................................................................. ..88
DUCTS ....................................................................................................92
STATIC PRESSURE GRAPHS ....................................................... ..96
TWINS ........................................................................................................100
CASSETTE (600X600) .........................................................................101
SUPERSLIM CASSETTE .......................................................................101
DUCTS .................................................................................................. 102
CEILING/FLOOR ................................................................................ ..103
ZENAXIAL COMMERCIAL RANGE
78
COMMERCIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
AXIAL COMMERCIAL RANGE
ZEN
OUTDOOR UNITS
We wish to highlight the axial outdoor units of KAYSUN’s Zen range. This is a machine designed to make maintenance tasks easier and to protect its main components, thereby extending the shelf life of the product.
We present the KAYSUN UK commercial range with axial outdoor ventilators. The main characteristics of this range we wish to highlight are its advanced technology, its efficiency, its versatility and its performance.
Combinations made with axial outdoor units are fitted with Inverter technology, maximising energy efficiency and seasonal performance indicators with a SCOP 4.0. The outdoor units of this type have an aesthetic with a robust design and good sound performance.
As part of the ZEN range with axial ventilator condensers, we have a wide variety of indoor units: Compact cassette
(600x600), SuperSlim cassette (840x840), ducts and Floor/Ceiling units. Some of these units can be installed in a TWINS configuration (one outdoor unit with two indoor units working together).
It could be said that the controls of this range are at the expected height. The KID-02 S, a wireless smart control that can inspect the operation of units and change configuration parameters. In terms of controls we have the KC-03 SPS, which can control up to 16 indoor units. Furthermore, it should be pointed out that this year some models in this range will have optional Wi-Fi control.
SMART CONTROLLERS
KAYSUN’s ZEN range has a range of controls at altitude. The cable and wireless controls have the most technologically-advanced functions and utilities, but with a modern and avant-garde aesthetic.
INSTALLATION PARAMETRES MODIFICATION+INSPECTION OF OPERATING PARAMETERS+FOLLOW ME+
WEEKLY TIMER+
FOLLOW ME+
UP TO 16 INDOOR UNITS+
STRONGER AND COMPACT+PERFORMANCE+ENERGY SAVING
SOUND LEVEL
+
KC-03 SPS KID-02 S
“HIGH-PERFORMANCE COMMERCIAL EQUIPMENT”
Go back to General Contents Go back to ZENaxial Index(Index)
79
Design and Install for you
ZE
N
AX
IAL
COM
ME
RCI
ALDUCT UNIT
With regard to the semi-industrial indoor units of the ZEN RANGE, we would like to highlight the Duct unit. We believe that this is one of the most comprehensive units in the market due to the great amount of options and functions included, such as:
• Removable filter (it can be extracted without touching the unit).
• Frame for the air inlet.• Frame for the air outlet.• Double possibility of air inlet (rear outlet or lower outlet).• Condensation pump.• Pre-installation for fresh air inlet.
• Electric box removable up to 1 metre apart from the unit's body.
• Voltage-free Alarm and ON/OFF dry contacts.• Switch to adapt the unit to the duct and to adjust the flow
required by the installation.• Up to 100 Pa available depending on the model.
TWO COMMUNICATION WIRESThe ZEN range units* only require two shielded wires without polarity for the communication between units. This characteristic makes the communication wiring works cheaper and easier.
WIFI ADAPTORIn 2017, KAYSUN UK will unveil its new optional adaptor for units in the ZEN range. These accessories connect the unit to our WIFI network and control it through an App installed on our smartphone. The application also includes a weekly timer
built into the App to ease and improve the control function of our air-conditioning system.
*Except for 3.5 kW units and high capacity Duct units.
S1
S1
S2
S2
NEW
Go back to General Contents Go back to ZENaxial Index(Index)
81
Design and Install for you
ZE
N
AX
IAL
COM
ME
RCI
AL
3.5 5.2 7.1 9.0 10.5 12.5 14.0 16.0POWER kW
CASSETTE (600 x 600)KCI-35 DVN10 KCI-52 DVN10
SETS
SUPERSLIM CASSETTE
KCIS-71 DVN10 KCIS-90 DVN10KCIS-105 DVN10
KCIS-105 DTN10KCIS-125 DVN10
KCIS-125 DTN10KCIS-140 DVN10
KCIS-140 DTN10KCIS-52 DVN10 KCIS-160 DTN10
CEILING / FLOOR
KPC-71 DVN10 KPC-90 DVN10KPC-105 DVN10
KPC-105 DTN10KPC-125 DVN10
KPC-125 DTN10KPC-140 DVN10
KPC-140 DTN10KPC-52 DVN10 KPC-160 DTN10
DUCTS
KPD-71 DVN10 KPD-90 DVN10KPD-105 DVN10
KPD-105 DTN10KPD-125 DVN10
KPD-125 DTN10KPD-140 DVN10
KPD-140 DTN10KPD-52 DVN10KPD-35 DVN10 KPD-160 DTN10
Go back to General Contents Go back to ZENaxial Index(Index)
82
COMMERCIAL RANGE SETS - AXIAL
CASSETTE ART FLUX 360º (600x600)
TECHNICAL SPECIFICATIONS
*Sound pressure at low speed.
**Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres.
*** Except for 35 (3.5 kW) models.
Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
SET KCI-35 DVN10 KCI-52 DVN10Cooling capacity (min./rated/max.) kW 0.62/3.52/4.40 0.79/5.28/6.15
Cooling capacity (min./rated/max.) Kcal/h 533/3027/3783 679/4540/5288
Cooling input (min./rated/max.) kW 0.210/0.960/1.692 0.270/1.630/2.365
SEER 6.1 6.3
Cooling energy class A++ A++
Heating capacity (min./rated/max.) kW 0.62/4.10/5.13 0.88/5.57/7.03
Heating capacity (min./rated/max.) Kcal/h 533/3525/4411 757/4789/6045
Heating input (min./rated/max.) kW 0.496/0.995/1.830 0.295/1.500/2.510
SCOP 4.0 4.0
Heating efficiency class A+ A+
Heating capacity -7ºC kW 3.18 4.25
COP -7ºC 3.08 2.77
OUTDOOR UNIT KUE-35 DVN10 KUE-52 DVN10Compressor type Rotary Rotary
Outdoor airflow m3/h 2000 2100
Sound pressure dB (A) 57 56.5
Refrigerant R-410 A R-410 A
Refrigerant charge / Additional charge** gr 1380 / 15 1480 / 15
Liquid pipe diameter mm (inch") ø6.35 (1/4") ø6.35 (1/4")
Gas pipe diameter mm (inch") ø9.52 (3/8") ø12.7 (1/2")
Max. piping length m 25 30
Pipe height difference m 10 20
Width/Height/Depth mm 800/554/333 800/554/333
Net weight Kg 34.5 35.5
Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5
Shielded communication wires*** mm2 (3+T)x2.5 2x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50
INDOOR UNIT KCI-35 DN10 KCI-52 DN10Indoor airflow m3/h 650/530/450 660/550/490
Sound pressure* dB (A) 34 38
Width/Height/Depth mm 570/260/570 570/260/570
Net weight Kg 16 16.5
Width/Height/Depth (panel) mm 647/50/647 647/50/647
Net weight (panel) Kg 2.5 2.5
Power cord mm2 with communication (2+T)x2.5
Shielded communication wires*** mm2 (3+T)x2.5 2x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50
Go back to General Contents (Index) Go back to ZENaxial Index
83
Design and Install for you
ZE
N
AX
IAL
COM
ME
RCI
AL
CONTROLLERS
The Cassette Artflux 360º 600x600 units stands out from other units thanks to its elegant design. Their small dimensions allows them for adapting to false ceiling installations and their 360º airflow provides user with highest comfort and covers every corner of the room.
• Pre-installation for fresh air inlet.
• Standard condensation pump.
• The 5.2 kW unit is compatible with TWINS configuration.
• Compact unit with integrated electric box.
• Voltage-free Alarm and ON/OFF dry contacts.
• 360º airflow
GENERAL CHARACTERISTICS
STANDARD CONDENSATION PUMP+
K01-LON K02-MODBUS K01-BACNET K01-KNXKAYNET CONTROL K01-WIFI
BMS AND SOFTWARE
INDIVIDUAL
For further information, please see our Controllers range
CENTRALISED
KCT-02.1 SRKC-02.1 H KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB
KID-02 S(*) RECOMMENDED
KID-02 S KC-03 SPS KC-01 S
UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you shall add to the € price for the set, the price
difference between the recommended controller and the selected controller.ELIGE TU CONTROL
CHOOSE YOUR CONTROL
PRICE LIST
MOD. SET MOD. INDOOR INDOOR UNIT PRICE MOD. OUTDOOR OUTDOOR UNIT PRICE RECOM. CONTROL SET PRICE
KCI-35 DVN10 KCI-35 DN10 £428 KUE-35 DVN10 £514.36 KID-02 S £943
KCI-52 DVN10 KCI-52 DN10 £496 KUE-52 DVN10 £649.26 KID-02 S £1,145
(*) Price calculation based on the recommended controller.
Go back to General Contents Go back to ZENaxial Index(Index)
84
COMMERCIAL RANGE SETS - AXIAL
ART FLUX 360º CASSETTE SUPERSLIMTECHNICAL SPECIFICATIONS
INDOOR UNIT KCIS-52 DN10 KCIS-71 DN10 KCIS-90 DN10Indoor airflow m3/h 1000/800/700 1450/1250/1100 1700/1460/1300
Sound pressure* dB (A) 37 39 44
Width/Height/Depth mm 840/205/840 840/245/840 840/245/840
Net weight Kg 21.3 24 26.5
Width/Height/Depth (panel) mm 950/55/950 950/55/950 950/55/950
Net weight (panel) Kg 5 5 5
Power cord mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Shielded communication wires mm2 2x1.5 2x1.5 2x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50
*Sound pressure at low speed.
**Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres.
Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
SET KCIS-52 DVN10 KCIS-71 DVN10 KCIS-90 DVN10Cooling capacity (min./rated/max.) kW 0.79/5.28/6.15 1.20/7.03/8.21 2.08/8.79/10.55
Cooling capacity (min./rated/max.) Kcal/h 679/4540/5289 1032/6045/7061 1789/7559/9073
Cooling input (min./rated/max.) kW 0.26/1.68/2.36 0.40/2.17/3.15 0.69/2.76/4.05
SEER 6.3 6.1 6.1
Cooling energy class A++ A++ A++
Heating capacity (min./rated/max.) kW 0.88/5.67/7.03 1.20/7.03/8.65 2.08/9.08/10.52
Heating capacity (min./rated/max.) Kcal/h 757/4876/6046 1032/6045/7439 1789/7809/9047
Heating input (min./rated/max.) kW 0.29/1.46/2.51 0.40/1.90/3.09 0.69/2.38/3.75
SCOP 4.0 4.0 4.0
Heating efficiency class A+ A+ A+
Heating capacity -7ºC kW 4.33 5.13 6.99
COP -7ºC 2.52 2.53 2.50
OUTDOOR UNIT KUE-52 DVN10 KUE-71 DVN10 KUE-90 DVN10Compressor type Rotary Double rotary Double rotary
Outdoor airflow m3/h 2100 2700 4300
Sound pressure dB (A) 56.5 60.5 59.5
Refrigerant R-410 A R-410 A R-410 A
Refrigerant charge / Additional charge** gr 1480 / 15 1950 / 30 2800 / 30
Liquid pipe diameter mm (inch") ø6.35 (1/4") ø9.52 (3/8") ø9.52 (3/8")
Gas pipe diameter mm (inch") ø12.7 (1/2") ø15.9 (5/8") ø15.9 (5/8")
Max. piping length m 30 50 50
Pipe height difference m 20 25 25
Width/Height/Depth mm 800/554/333 845/702/363 946/810/410
Net weight Kg 35.5 49 62.9
Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x4
Shielded communication wires mm2 2x1.5 2x1.5 2x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50
Go back to General Contents (Index) Go back to ZENaxial Index
85
Design and Install for you
ZE
N
AX
IAL
COM
ME
RCI
AL
KCIS-105 DN10
KCIS-105 DN10
KCIS-125 DN10
KCIS-125 DN10
KCIS-140 DN10
KCIS-140 DN10
KCIS-160 DN10
1900/1750/1460 1900/1750/1460 1850/1600/1400 1850/1600/1400 1850/1600/1400 1850/1600/1400 1900/1650/1450
47 47 48 48 45 48 46
840/245/840 840/245/840 840/287/840 840/287/840 840/287/840 840/287/840 840/287/840
25.6 25.6 26.1 26.1 28 28 31
950/55/950 950/55/950 950/55/950 950/55/950 950/55/950 950/55/950 950/55/950
5 5 5 5 5 5 5
(2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5
220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
KCIS-105 DVN10
KCIS-105 DTN10
KCIS-125 DVN10
KCIS-125 DTN10
KCIS-140 DVN10
KCIS-140 DTN10
KCIS-160 DTN10
2.93/10.55/12.09 2.93/10.55/12.02 3.22/12.31/13.19 3.22/12.31/13.19 3.99/13.78/16.12 3.99/13.78/16.12 4.98/16.12/18.462520/9073/10397 2520/9073/10337 2769/10586/11343 2769/10586/11343 3431/11851/13863 3431/11851/13863 4282/13863/15875
0.97/4.06/4.62 0.97/4.06/4.62 1.07/4.09/5.07 1.07/4.09/5.07 1.33/5.16/6.20 1.33/5.16/6.20 11.66/6.39/7.10
6.1 6.1 5.6 5.6 5.6 5.6 5.6
A++ A++ A+ A+ A+ A+ A+
2.64/11.13/13.19 2.64/11.13/13.19 2.93/13.48/14.65 3.4/12.89/14.5 4.19/15.53/17.59 4.19/15.53/17.59 5.28/18.17/20.51
2296/9572/11343 2296/9572/11343 2520/11593/12599 2924/11085/12470 3603/13356/15127 3603/13356/15127 4540/15626/17638
0.88/3.08/4.69 0.88/3.08/4.69 0.97/3.53/5.23 0.97/3.53/5.23 1.40/4.55/6.76 1.40/4.55/6.76 1.76/5.73/7.32
4.0 4.0 4.0 4.0 4.0 4.0 4.0
A+ A+ A+ A+ A+ A+ A+
8.76 8.93 9.73 9.73 10.17 10.17 10.17
2.48 2.44 2.47 2.48 2.29 2.60 2.66
KUE-105 DVN10
KUE-105 DTN10
KUE-125 DVN10
KUE-125 DTN10
KUE-140 DVN10
KUE-140 DTN10
KUE-160 DTN10
Double rotary Double rotary Double rotary Double rotary Double rotary Double rotary Double rotary
4300 4300 4300 4300 6800 6800 7200
61 62 62.5 63 65 65 62.5
R-410 A R-410 A R-410 A R-410 A R-410 A R-410 A R-410 A
3200 / 30 3200 / 30 3650 / 30 3650 / 30 4000 / 30 4000 / 30 4300 / 30
ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8")
ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8")
65 65 65 65 65 65 65
30 30 30 30 30 30 30
946/810/410 946/810/410 946/810/410 946/810/410 952/1333/415 952/1333/415 952/1333/415
67.2 78.9 70.5 85 95.1 108.1 112.8
(2+T)x4 (4+T)x2.5 (2+T)x4 (4+T)x2.5 (2+T)x6 (4+T)x4 (4+T)x6
2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5
220-240/1/50 380-400/3/50 220-240/1/50 380-400/3/50 220-240/1/50 380-400/3/50 380-400/3/50
Go back to General Contents Go back to ZENaxial Index(Index)
86
COMMERCIAL RANGE SETS - AXIAL
ART FLUX 360º CASSETTE SUPERSLIM
• Fresh air inlet (optional).
• Standard condensation pump.
• Units 52, 71 and 90 are compatible with TWINS configuration.
• Louvres position memory.
• Slim design compact unit.
• Voltage-free Alarm and ON/OFF dry contacts.
• 360º airflow.
• KC-03 SPS controller, for independent vane control.
• Side air outlet for a duct (optional).
GENERAL CHARACTERISTICS
CONTROLLERS
K01-LON K02-MODBUS K01-BACNET K01-KNXKAYNET CONTROL K01-WIFI
BMS AND SOFTWARE
INDIVIDUAL
For further information, please see our Controllers range
CENTRALISED
KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB
PRICE CALCULATION BASED ON
THE RECOMMENDED CONTROLLER
If you want a different controller, you shall add to
the € price for the set, the price difference between the
recommended controller and the selected controller.
KID-02 S KC-03 SPS
The KAYSUN UK Cassette type units are fitted with a 360º air diffusion system that allows them to reach every corner of the room and provide maximum comfort to users. They have an impeccable appearance, a compact structure and a slim design to adapt to spaces with low ceilings.
ELIGE TU CONTROL
CHOOSE YOUR CONTROL
Go back to General Contents (Index) Go back to ZENaxial Index
87
Design and Install for you
ZE
N
AX
IAL
COM
ME
RCI
AL
STANDARD CONDENSATION PUMP+
KID-02 S(*) RECOMMENDED
OPTIONALMOTORIZED PANEL
If you want the motorised panel
you will also need the KC-03 SPS control
TWINS COMBINATIONS (OPTIONAL)+
PRICE LIST
MOD. SET MOD. INDOORINDOOR UNIT
PRICEMOD. OUTDOOR
OUTDOOR UNIT PRICE
RECOM. CONTROL SET PRICE
KCIS-52 DVN10 KCIS-52 DN10 £510 KUE-52 DVN10 £649 KID-02 S £1,043
KCIS-71 DVN10 KCIS-71 DN10 £603 KUE-71 DVN10 £896 KID-02 S £1,350
KCIS-90 DVN10 KCIS-90 DN10 £763 KUE-90 DVN10 £1,014 KID-02 S £1,600
KCIS-105 DVN10 KCIS-105 DN10 £776 KUE-105 DVN10 £1,321 KID-02 S £1,677
KCIS-105 DTN10 KCIS-105 DN10 £776 KUE-105 DTN10 £1,437 KID-02 S £1,770
KCIS-125 DVN10 KCIS-125 DN10 £795 KUE-125 DVN10 £1,521 KID-02 S £1,853
KCIS-125 DTN10 KCIS-125 DN10 £795 KUE-125 DTN10 £1,596 KID-02 S £1,913
KCIS-140 DVN10 KCIS-140 DN10 £814 KUE-140 DVN10 £1,761 KID-02 S £2,060
KCIS-140 DTN10 KCIS-140 DN10 £814 KUE-140 DTN10 £1,761 KID-02 S £2,060
KCIS-160 DTN10 KCIS-160 DN10 £851 KUE-160 DTN10 £1,925 KID-02 S £2,222
(*) Price calculation based on the recommended controller.
Go back to General Contents Go back to ZENaxial Index(Index)
88
COMMERCIAL RANGE SETS - AXIAL
CEILING / FLOORTECHNICAL SPECIFICATIONS
SET KPC-52 DVN10 KPC-71 DVN10 KPC-90 DVN10Cooling capacity (min./rated/max.) kW 0.79/5.28/6.15 1.2/7.03/8.21 2.08/8.79/10.55
Cooling capacity (min./rated/max.) Kcal/h 679/4541/5289 1032/6046/7061 1789/7559/9073
Cooling input (min./rated/max.) kW 0.27/1.63/2.37 0.4/2.29/3.16 0.69/2.96/4.06
SEER 6.5 6.1 6.1
Cooling energy class A++ A++ A++
Heating capacity (min./rated/max.) kW 0.88/5.67/7.03 1.2/7.03/8.65 2.08/9.38/10.84
Heating capacity (min./rated/max.) Kcal/h 757/4876/6046 1032/6046/7439 1789/8067/9322
Heating input (min./rated/max.) kW 0.26/1.46/2.51 0.4/1.9/3.09 0.69/2.48/3.87
SCOP 4.0 4.0 4.0
Heating efficiency class A+ A+ A+
Heating capacity -7ºC kW 4.33 5.13 7.25
COP -7ºC 2.61 2.64 2.53
OUTDOOR UNIT KUE-52 DVN10 KUE-71 DVN10 KUE-90 DVN10Compressor type Rotary Double rotary Double rotary
Outdoor airflow m3/h 2100 2700 4300
Sound pressure dB (A) 56.5 60.5 59.5
Refrigerant R-410 A R-410 A R-410 A
Refrigerant charge / Additional charge** gr 1480 / 15 1950 / 30 2800 / 30
Liquid pipe diameter mm (inch") ø6.35 (1/4") ø9.52 (3/8") ø9.52 (3/8")
Gas pipe diameter mm (inch") ø12.7 (1/2") ø15.9 (5/8") ø15.9 (5/8")
Max. piping length m 30 50 50
Pipe height difference m 20 25 25
Width/Height/Depth mm 800/554/333 845/702/363 946/810/410
Net weight Kg 35.5 49 62.9
Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x4
Shielded communication wires mm2 2x1.5 2x1.5 2x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50
INDOOR UNIT KPC-52 DN10 KPC-71 DN10 KPC-90 DN10Indoor airflow m3/h 900/800/700 1180/1050/850 1650/1450/1250
Sound pressure* dB (A) 34 42 44
Width/height/depth (ceiling installation) mm 1068/235/675 1068/235/675 1285/235/675
Net weight Kg 25.8 25 31
Power cord mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Shielded communication wires mm2 2x1.5 2x1.5 2x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50
*Sound pressure at low speed.
**Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres.
Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
Go back to General Contents (Index) Go back to ZENaxial Index
89
Design and Install for you
ZE
N
AX
IAL
COM
ME
RCI
AL
KUE-105 DVN10 KUE-105 DTN10 KUE-125 DVN10 KUE-125 DTN10 KUE-140 DVN10 KUE-140 DTN10 KUE-160 DTN10Double rotary Double rotary Double rotary Double rotary Double rotary Double rotary Double rotary
4300 4300 4300 4300 6800 6800 7200
61 62 62.5 63 65 65 62.5
R-410 A R-410 A R-410 A R-410 A R-410 A R-410 A R-410 A
3200 / 30 3200 / 30 3650 / 30 3650 / 30 4000 / 30 4000 / 30 4300 / 30
ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8")
ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8")
65 65 65 65 65 65 65
30 30 30 30 30 30 30
946/810/410 946/810/410 946/810/410 946/810/410 952/1333/415 952/1333/415 952/1333/415
67.2 78.9 70.5 85 95.1 108.1 112.8
(2+T)x4 (4+T)x2.5 (2+T)x4 (4+T)x2.5 (2+T)x6 (4+T)x4 (4+T)x6
2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5
220-240/1/50 380-400/3/50 220-240/1/50 380-400/3/50 220-240/1/50 380-400/3/50 380-400/3/50
KPC-105 DN10 KPC-105 DN10 KPC-125 DN10 KPC-125 DN10 KPC-140 DN10 KPC-140 DN10 KPC-160 DN102048/1767/1403 2048/1767/1403 2271/1886/1394 2100/1800/1400 2100/1800/1400 2100/1800/1400 2250/1660/1280
40 40 43 41 41 41 45
1650/235/675 1650/235/675 1650/235/675 1650/235/675 1650/235/675 1650/235/675 1650/235/675
40.3 40.3 40.5 40.5 38.2 38.2 40.5
(2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5
220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
KPC-105 DVN10 KPC-105 DTN10 KPC-125 DVN10 KPC-125 DTN10 KPC-140 DVN10 KPC-140 DTN10 KPC-160 DTN102.93/10.55/12.02 2.93/10.55/12.02 3.22/12.31/13.19 3.22/12.31/13.19 4.1/14.07/16.41 4.1/14.07/16.41 4.98/15.82/18.11
2520/9073/10337 2520/9073/10337 2769/10587/11343 2769/10587/11343 3526/12100/14113 3526/12100/14113 4283/13605/15575
0.98/4.06/4.62 0.98/4.06/4.62 1.07/4.23/5.07 1.07/4.23/5.07 1.37/5.19/6.31 1.37/5.19/6.31 1.66/6.06/6.97
6.3 6.1 6.1 6.1 6.1 6.1 6.1
A++ A++ A++ A++ A++ A++ A++
2.64/11.13/13.19 2.64/11.13/13.19 3/13.5/14.7 2.84/12.9/14.01 4.4/16.41/18.46 4.4/16.41/18.46 5.28/18.17/20.51
2270/9572/11343 2270/9572/11343 2580/11610/12642 2442/11103/12049 3784/14113/15876 3784/14113/15876 4541/15626/17639
0.88/2.99/4.69 0.88/2.99/4.69 0.95/3.54/5 0.95/3.39/5 1.47/4.81/6.59 1.47/4.81/6.59 1.76/5.65/7.32
4.0 4.0 4.0 4.0 4.0 4.0 4.0
A+ A+ A+ A+ A+ A+ A+
9.29 9.11 9.73 9.73 10.44 10.44 10.62
2.48 2.43 2.61 2.73 2.54 2.71 2.76
Go back to General Contents Go back to ZENaxial Index(Index)
90
COMMERCIAL RANGE SETS - AXIAL
CEILING / FLOOR
KAYSUN UK Zen range makes air conditioning at your disposal through its most versatile product, the Ceiling/Floor units. Compact and state-of-the-art design that integrates into every room environment. A simple and, at the same time, versatile unit.
• Easy access to components for maintenance.
• Floor or ceiling installation.
• New numerical display in the receiver.
• Improved airflow for a greater comfort.
• Voltage-free Alarm and ON/OFF dry contacts.
• KC-03 SPS wired controller (optional).
GENERAL CHARACTERISTICS
CONTROLLERS
BMS AND SOFTWARE
INDIVIDUAL
For further information, please see our Controllers range
CENTRALISED
KCT-02.1 SR KCC-16 KCCT-64 I KCC-64 I-PSKC-02.1 H KCC-64 WEB
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you should add to the € price for the set the price difference
between recommended controller and the selected controller.
KID-02 S KC-03 SPS KC-01 S
ELIGE TU CONTROL
CHOOSE YOUR CONTROL
Go back to General Contents (Index) Go back to ZENaxial Index
91
Design and Install for you
ZE
N
AX
IAL
COM
ME
RCI
AL
KID-02 S(*) RECOMMENDED
Enquire about availability and price.
ALARM AND VOLTAGE-FREE CONTACTS +
CEILING/FLOOR COMPATIBLE +
PRICE LIST
MOD. SET MOD. INDOORINDOOR UNIT
PRICEMOD. OUTDOOR
OUTDOOR UNIT PRICE
RECOM. CONTROL SET PRICE
KPC-52 DVN10 KPC-52 DN10 £552 KUE-52 DVN10 £649 KID-02 S £1,201
KPC-71 DVN10 KPC-71 DN10 £601 KUE-71 DVN10 £896 KID-02 S £1,498
KPC-90 DVN10 KPC-90 DN10 £705 KUE-90 DVN10 £1,014 KID-02 S £1,719
KPC-105 DVN10 KPC-105 DN10 £720 KUE-105 DVN10 £1,321 KID-02 S £2,042
KPC-105 DTN10 KPC-105 DN10 £720 KUE-105 DTN10 £1,437 KID-02 S £2,157
KPC-125 DVN10 KPC-125 DN10 £721 KUE-125 DVN10 £1,521 KID-02 S £2,242
KPC-125 DTN10 KPC-125 DN10 £721 KUE-125 DTN10 £1,596 KID-02 S £2,317
KPC-140 DVN10 KPC-140 DN10 £755 KUE-140 DVN10 £1,761 KID-02 S £2,516
KPC-140 DTN10 KPC-140 DN10 £755 KUE-140 DTN10 £1,761 KID-02 S £2,516
KPC-160 DTN10 KPC-160 DN10 £769 KUE-160 DTN10 £1,925 KID-02 S £2,695
(*) Price calculation based on the recommended controller.
Go back to General Contents Go back to ZENaxial Index(Index)
92
COMMERCIAL RANGE SETS - AXIALCompatible con
DUCTSTECHNICAL SPECIFICATIONS
POWER CONSUMPTION KPD-35 DVN10 KPD-52 DVN10 KPD-71 DVN10 KPD-90 DVN10Cooling capacity (min./rated/max.) kW 0.62/3.52/4.4 0.79/5.28/6.15 1.2/7.03/8.21 2.08/8.79/10.55
Cooling capacity (min./rated/max.) Kcal/h 533/3027/3784 679/4541/5289 1032/6046/7061 1789/7559/9073
Cooling input (min./rated/max.) kW 0.21/1.03/1.69 0.26/1.69/2.37 0.4/2.29/3.16 0.69/2.88/4.06
SEER 6.1 6.5 6.1 6.1
Cooling energy class A++ A++ A++ A++
Heating capacity (min./rated/max.) kW 0.62/3.81/4.98 0.88/5.67/7.03 1.2/7.03/8.65 2.08/9.38/10.84
Heating capacity (min./rated/max.) Kcal/h 533/3277/4283 757/4876/6046 1032/6046/7439 1789/8067/9322
Heating input (min./rated/max.) kW 0.5/1/1.79 0.29/1.46/2.51 0.4/1.9/3.09 0.69/2.46/3.87
SCOP 4.0 4.0 4.0 4.0
Heating efficiency class A+ A+ A+ A+
Heating capacity -7ºC kW 2.92 4.16 5.13 7.25
COP -7ºC 2.57 2.51 2.68 2.6
OUTDOOR UNIT KUE-35 DVN10 KUE-52 DVN10 KUE-71 DVN10 KUE-90 DVN10Compressor type Rotary Rotary Double rotary Double rotary
Outdoor airflow m3/h 2000 2100 2700 4300
Sound pressure dB (A) 57 56.5 60.5 59.5
Refrigerant R-410 A R-410 A R-410 A R-410 A
Refrigerant charge / Additional charge**
gr 1380 / 15 1480 / 15 1950 / 30 2800 / 30
Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8") ø9.52 (3/8")
Gas pipe diameter mm (Inch) ø9.52 (3/8") ø12.7 (1/2") ø15.9 (5/8") ø15.9 (5/8")
Max. piping length m 25 30 50 50
Pipe height difference m 10 20 25 25
Width/Height/Depth mm 800/554/333 800/554/333 845/702/363 946/810/410
Net weight Kg 34.5 35.5 49 62.9
Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x4
Shielded communication wires*** mm2 (3+T)x2.5 2x1.5 2x1.5 2x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
INDOOR UNIT KPD-35 DN10 KPD-52 DN10 KPD-71 DN10 KPD-90 DN10Indoor airflow m3/h 640/550/470 1000/900/750 1480/1300/1090 1720/1500/1230
Static pressure range (rated) Pa 0-45 (25) 0-100 (80) 0-100 (80) 0-100 (80)
Sound pressure* dB (A) 35 37 38 44
Width/Height/Depth mm 700/210/635 920/270/635 920/270/635 1140/270/775
Net weight Kg 18 27 28 35
Power cord mm2 with communication (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Shielded communication wires*** mm2 (3+T)x2.5 2x1.5 2x1.5 2x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
*Sound pressure at low speed. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres.
Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
*** Except for 3.5 kW units.
Go back to General Contents (Index) Go back to ZENaxial Index
93
Design and Install for you
ZE
N
AX
IAL
COM
ME
RCI
AL
KUE-105 DVN10 KUE-105 DTN10 KUE-125 DVN10 KUE-125 DTN10 KUE-140 DVN10 KUE-140 DTN10 KUE-160 DTN10Double rotary Double rotary Double rotary Double rotary Double rotary Double rotary Double rotary
4300 4300 4300 4300 6800 6800 7200
61 62 62.5 63 65 65 62.5
R-410 A R-410 A R-410 A R-410 A R-410 A R-410 A R-410 A
3200 / 30 3200 / 30 3650 / 30 3650 / 30 4000 / 30 4000 / 30 4300 / 30
ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8")
ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8")
65 65 65 65 65 65 65
30 30 30 30 30 30 30
946/810/410 946/810/410 946/810/410 946/810/415 952/1333/415 952/1333/415 952/1333/415
67.2 78.9 70.5 85 95.1 108.1 112.8
(2+T)x4 (4+T)x2.5 (2+T)x4 (4+T)x2.5 (2+T)x6 (4+T)x4 (4+T)x6
2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5
220-240/1/50 380-400/3/50 220-240/1/50 380-400/3/50 220-240/1/50 380-400/3/50 380-400/3/50
KPD-105 DN10 KPD-105 DN10 KPD-125 DN10 KPD-125 DN10 KPD-140 DN10 KPD-140 DN10 KPD-160 DN101750/1500/1280 1750/1500/1280 2200/1900/1600 2200/1900/1600 2200/1900/1600 2200/1900/1600 2200/1900/1600
0-100 (80) 0-100 (80) 0-100 (80) 0-100 (80) 0-100 (80) 0-100 (80) 0-100 (80)
40 40 44 44 45 45 45
1200/300/865 1200/300/865 1200/300/865 1200/300/865 1200/300/865 1200/300/865 1200/300/865
45 45 43.4 43.4 43.2 43.2 43.1
(2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5
220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
KPD-105 DVN10 KPD-105 DTN10 KPD-125 DVN10 KPD-125 DTN10 KPD-140 DVN10 KPD-140 DTN10 KPD-160 DTN102.93/10.55/12.02 2.93/10.55/12.02 3.22/12.31/13.19 3.22/12.31/13.19 4.1/14.07/16.41 4.1/14.07/16.41 4.98/15.82/18.11
2520/9073/10337 2520/9073/10337 2769/10587/11343 2769/10587/11343 3526/12100/14113 3526/12100/14113 4283/13605/15575
0.98/3.97/4.62 0.98/3.97/4.62 1.07/4.09/5.07 1.07/4.09/5.07 1.37/5.12/6.31 1.37/5.12/6.31 1.66/5.26/6.97
6.3 6.1 5.6 5.6 6.1 6.1 6.1
A++ A++ A+ A+ A++ A++ A++
2.64/11.13/13.19 2.64/11.13/13.19 2.93/13.48/14.65 2.93/13.48/14.65 4.34/16.12/18.13 4.34/16.12/18.13 5.28/18.17/20.51
2270/9575/11343 2270/9575/11343 2520/11593/12599 2520/11593/12599 3732/13863/15592 3732/13863/15592 4541/15626/17639
0.88/2.92/4.69 0.88/2.92/4.69 0.98/3.54/5.23 0.98/3.54/5.23 1.45/4.36/6.48 1.45/4.36/6.48 1.76/5.03/7.32
4.0 4.0 4.0 4.0 4.0 4.0 4.0
A+ A+ A+ A+ A+ A+ A+
9.29 9.29 9.73 9.73 10.79 10.79 10.88
2.56 2.56 2.75 2.78 2.77 2.71 2.86
Go back to General Contents Go back to ZENaxial Index(Index)
94
COMMERCIAL RANGE SETS - AXIALCompatible con
DUCTS
KAYSUN UK ducts units offer a wide range of features, which turns them into one of the best products in the market. These units can be easily installed in small spaces, such as compact suspended ceilings, thanks to the tilted position of their battery, which provides them with a slim design.
GENERAL CHARACTERISTICS
CONTROLLERS
K01-LON K02-MODBUS K01-BACNET K01-KNXKAYNET CONTROL K01-WIFI
BMS AND SOFTWARE
INDIVIDUAL
For further information, please see our Controllers range
CENTRALISED
KCT-02.1 SRKC-02.1 H KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you should add to the € price for the set the price difference
between recommended controller and the selected controller.
• Easily removable filter.
• Air supply duct and return air duct pre-installation frames.
• Double possibility for air inlet (rear or lower intake).
• Fresh air intake at a side of the unit.
• Voltage-free Alarm and ON/OFF dry contacts.
• Standard condensation pump of up to 750 mm in height.
• Electric box removable up to 1 metre apart from the unit's
body.
• Up to 100 Pa available depending on the model.
KID-02 S KC-03 SPS KC-01 S
ELIGE TU CONTROL
CHOOSE YOUR CONTROL
Go back to General Contents (Index) Go back to ZENaxial Index
95
Design and Install for you
ZE
N
AX
IAL
COM
ME
RCI
AL
KC-03 SPS
(*) RECOMMENDED
Compatible with
STANDARD CONDENSATION PUMP, up to 750 mm IN HEIGHT+
ALARM AND VOLTAGE-FREE CONTACTS +
Enquire about availability and price.
PRICE LIST
MOD. SET MOD. INDOORINDOOR UNIT
PRICEMOD. OUTDOOR
OUTDOOR UNIT PRICE
RECOM. CONTROL SET PRICE
KPD-35 DVN10 KPD-35 DN10 £346 KUE-35 DVN10 £514 KC-03 SPS £861
KPD-52 DVN10 KPD-52 DN10 £347 KUE-52 DVN10 £649 KC-03 SPS £996
KPD-71 DVN10 KPD-71 DN10 £375 KUE-71 DVN10 £896 KC-03 SPS £1,272
KPD-90 DVN10 KPD-90 DN10 £545 KUE-90 DVN10 £1,014 KC-03 SPS £1,559
KPD-105 DVN10 KPD-105 DN10 £548 KUE-105 DVN10 £1,321 KC-03 SPS £1,870
KPD-105 DTN10 KPD-105 DN10 £548 KUE-105 DTN10 £1,437 KC-03 SPS £1,985
KPD-125 DVN10 KPD-125 DN10 £567 KUE-125 DVN10 £1,521 KC-03 SPS £2,088
KPD-125 DTN10 KPD-125 DN10 £567 KUE-125 DTN10 £1,596 KC-03 SPS £2,163
KPD-140 DVN10 KPD-140 DN10 £681 KUE-140 DVN10 £1,761 KC-03 SPS £2,442
KPD-140 DTN10 KPD-140 DN10 £681 KUE-140 DTN10 £1,761 KC-03 SPS £2,442
KPD-160 DTN10 KPD-160 DN10 £718 KUE-160 DTN10 £1,925 KC-03 SPS £2,644
(*) Price calculation based on the recommended controller.
Go back to General Contents Go back to ZENaxial Index(Index)
96
COMMERCIAL RANGE SETS - GRAPHICS OF DUCTCompatible con
DUCTS STATIC PRESSURE GRAPHS
KPD-35 DN10
KPD-52 DN10
Airflow (m3/h) Airflow (m3/h) Airflow (m3/h)
High Medium Low
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
Airflow (m3/h) Airflow (m3/h) Airflow (m3/h)
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
High Medium Low
Go back to General Contents (Index) Go back to ZENaxial Index
97
Design and Install for you
ZE
N
AX
IAL
COM
ME
RCI
AL
KPD-90 DN10
KPD-71 DN10
Airflow (m3/h) Airflow (m3/h) Airflow (m3/h)
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
Airflow (m3/h) Airflow (m3/h) Airflow (m3/h)
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
High Medium Low
High Medium Low
Go back to General Contents Go back to ZENaxial Index(Index)
98
COMMERCIAL RANGE SETS - GRAPHICS OF DUCTCompatible con
DUCTS STATIC PRESSURE GRAPHS
Airflow (m3/h) Airflow (m3/h) Airflow (m3/h)
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
KPD-105 DN10
KPD-125 DN10
Airflow (m3/h) Airflow (m3/h) Airflow (m3/h)
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
High Medium Low
High Medium Low
Go back to General Contents (Index) Go back to ZENaxial Index
99
Design and Install for you
ZE
N
AX
IAL
COM
ME
RCI
AL
Airflow (m3/h) Airflow (m3/h) Airflow (m3/h)
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
KPD-140 DN10
KPD-160 DN10
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
High Medium Low
High Medium Low
Go back to General Contents Go back to ZENaxial Index(Index)
100
COMMERCIAL RANGE TWINS
TWINS
The balance in the Zen range results in good service and greater comfort for users and installers.
Zen Inverter units are fitted with a specific electronic board that allows for connecting two indoor units to the same outdoor unit.
TWIN technology can be applied to compact Cassette 600x600, Art Flux 360º SuperSlim Cassette, ducts and Ceiling/Floor units. Furthermore, sets of different indoor units can be made; i.e, you can combine, for example, a duct unit with a ceiling/floor type unit, among many other possibilities, provided that both indoor units are the same capacity.
The capacities with which you can arrange Twins combinations are the following:- Outdoor unit of 10.5kW with two indoor units of 5.2kW- Outdoor unit of 14.0kW with two indoor units of 7.1kW- Outdoor unit of 17.6kW with two indoor units of 9.0kW
Twins units represent the versatility and balance of the Zen range, and are presented as an option for commercial spaces that require more than one indoor unit to achieve a suitable air-conditioning without demanding more outdoor units.
PIPE DISTANCE
Maximum distance (L+L1+L2)
52+52 indoor combination (A+B) 50 m.
71+71 indoor combination (A+B) 65 m.
90+90 indoor combination (A+B) 65 m.
Maximum distance between the branch pipe and the indoor unit (L1 and L2) 15 m.
Maximum difference in length between the branch pipe and the indoor units (L1-L2) 10 m.
LEVEL DIFFERENCEBetween outdoor unit and indoor units 20 m.
Between indoor units (A and B) 0.5 m.
UNIT BUNIT A
OUTDOOR UNIT
L
L1 L2
DIFFERENT TYPES OF INDOOR UNIT CAN BE COMBINEDIn Twins sets, one can choose from two types of indoor unit. You can create your own Twin set by combining the 2 indoor units that suit you best, provided that they have the same capacity.
Maximum height difference between indoor units of a TWIN system: 0.5 metresBranch pipe not included. Add T-type branch pipe or KCMI 112 branch pipe
OUTDOOR UNIT INDOOR UNIT600x600 cassetteSuperSlim cassette
DuctFloor / ceiling
INDOOR UNIT CONTROL
KID-02 SKC-03 SPS
600x600 cassetteSuperSlim cassette
DuctFloor / ceiling
Go back to General Contents (Index) Go back to ZENaxial Index
101
Design and Install for you
ZE
N
AX
IAL
COM
ME
RCI
AL
KID-02 S SUPERSLIM CASSETTE 360º
SUPERSLIM CASSETTE 360º
KID-02 S CASSETTE CASSETTE
x2
x2
CASSETTE 600 x 600
INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE
KCI-52 DN10 KUE-105 DVN10 KID-02 S £2,315
KCI-52 DN10 KUE-105 DTN10 KID-02 S £2,431
SUPERSLIM CASSETTE
INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE
KCIS-52 DN10 KUE-105 DVN10 KID-02 S £2,342
KCIS-52 DN10 KUE-105 DTN10 KID-02 S £2,357
KCIS-71 DN10 KUE-140 DVN10 KID-02 S £2,967
KCIS-71 DN10 KUE-140 DTN10 KID-02 S £2,967
KCIS-90 DN10 KUE-160 DTN10 KID-02 S £3,454
Go back to General Contents Go back to ZENaxial Index(Index)
102
COMMERCIAL RANGE TWINS
TWINS
x2
KC-03 SPS DUCTS DUCTS
DUCTS
INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE
KPD-52 DN10 KUE-105 DVN10 KC-03 SPS £2,016
KPD-52 DN10 KUE-105 DTN10 KC-03 SPS £2,132
KPD-71 DN10 KUE-140 DVN10 KC-03 SPS £2,511
KPD-71 DN10 KUE-140 DTN10 KC-03 SPS £2,511
KPD-90 DN10 KUE-160 DTN10 KC-03 SPS £3,016
Go back to General Contents (Index) Go back to ZENaxial Index
103
Design and Install for you
ZE
N
AX
IAL
COM
ME
RCI
AL
x2
KID-02 S CEILING/FLOOR CEILING/FLOOR
CEILING/FLOOR
INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE
KPC-52 DN10 KUE-105 DVN10 KID-02 S £3,315
KPC-52 DN10 KUE-105 DTN10 KID-02 S £3,431
KPC-71 DN10 KUE-140 DVN10 KID-02 S £4,305
KPC-71 DN10 KUE-140 DTN10 KID-02 S £4,305
KPC-90 DN10 KUE-160 DTN10 KID-02 S £5,045
Go back to General Contents Go back to ZENaxial Index(Index)
Design and Install for you
105
ZENCENTRIFUGAL COMMERCIAL RANGE
INTRODUCTION TO THE PRODUCT RANGE ........................................ ..106
SETS ........................................................................................................ ..108
SUPERSLIM CASSETTE ................................................................... ..110
CEILING/FLOOR ............................................................................... ..112
DUCTS .............................................................................................. ..114
STATIC PRESSURE GRAPHS .................................................... ..116
TWINS .................................................................................................... ..118
SUPERSLIM CASSETTE ................................................................... ..119
CEILING/FLOOR ............................................................................... ..119
DUCTS .............................................................................................. ..119
COMMERCIAL RANGE
106
INTRODUCTION TO THE RANGE OF PRODUCTS
CENTRIFUGAL COMMERCIAL RANGE
ZEN
We present the KAYSUN UK commercial range with centrifugal outdoor ventilators. The main characteristic of this range that we wish to highlight is its adaptability: it is a machine ideal for installation in indoor spaces, where there is no space for an outdoor axial unit outside.
The combinations with outdoor centrifugal units are pieces of equipment with a compressor and indoor ventilators with DC Inverter technology. These units with a centrifugal ventilator embody one of our key principles (versatility) and have been created to provide a customised solution that is suited to the need to integrate them into the facade of street premises.
The centrifugal ZEN range contains SuperSlim Cassette (840x840) indoor units, ducts and floor/ceiling units. These units can be installed in a TWINS configuration (one outdoor unit with two indoor units working together).
It could be said that the controls of this range are at the expected height. The KID-02 S, a wireless smart control that can inspect the operation of units and change configuration parameters. In terms of controls we have the KC-03 SPS, which can control up to 16 indoor units. Furthermore, it should be pointed out that this year some models in this range will have optional Wi-Fi control.
SMART CONTROLLERS
KAYSUN’s ZEN range has a range of controls at altitude. The cable and wireless controls have the most technologically-advanced functions and utilities, but with a modern and avant-garde aesthetic.
CENTRIFUGAL OUTDOOR UNITS
The centrifugal outdoor units offered by KAYSUN UK are a highly recommended option for systems where there is no outdoor space for installation.
14 AND 16 KW+FLEXIBLE CONFIGURATION CONDENSATION AIR INLET AND OUTLET+60 PA AVAILABLE PRESURE+
INSTALLATION PARAMETRES MODIFICATION+OPERATION PARAMETERS CHECKING+
WEEKLY TIMER+
FOLLOW ME+FOLLOW ME+
UP TO 16 INDOOR UNITS+
KC-03 SPS KID-02 S
“HIGH COMMERCIAL EQUIPMENT”
Go back to General Contents Go back to ZEN centrifugal Index(Index)
Design and Install for you
107
ZE
N
CEN
TRIF
UGA
L CO
MM
ERCI
AL
DUCT UNIT
With regard to the semi-industrial indoor units of the ZEN RANGE, we would like to highlight the Duct unit. We believe that this is one of the most comprehensive units in the market due to the great amount of options and functions included, such as:
• Removable filter (it can be extracted without touching the unit).
• Frame for the air inlet.• Frame for the air outlet.• Double possibility of air inlet (rear outlet or lower outlet).• Condensation pump.• Pre-installation for fresh air inlet.
• Electric box removable up to 1 metre apart from the unit's body.
• Voltage-free Alarm and ON/OFF dry contacts.• Switch to adapt the unit to the duct and to adjust the
flow required by the installation.• Up to 100 Pa available depending on the model.
TWO COMMUNICATION WIRESThe ZEN range units only require two shielded wires without polarity for the communication among units. This new characteristic makes the communication wiring works cheaper and easier.
WIFI ADAPTORIn 2017, KAYSUN UK will unveil its new optional adaptor for units in the ZEN range. These accessories connect the unit to our domestic WiFi network and control it through an App installed on our smartphone. The application also includes a weekly timer built into the App to ease and improve the control
function of our air-conditioning system.
S1
S1
S2
S2
NEW
Go back to General Contents Go back to ZEN centrifugal Index(Index)
Design and Install for you
109
ZE
N
CEN
TRIF
UGA
L CO
MM
ERCI
AL
3.5 5.2 7.1 9.0 10.5 12.5 14.0 16.0POWER kW
SETS
SUPERSLIM CASSETTE
KCISC-160 DTN10KCISC-140 DTN10
CEILING/FLOOR
KPCC-160 DTN10KPCC-140 DTN10
DUCTS
KPDC-160 DTN10KPDC-140 DTN10
Go back to General Contents Go back to ZEN centrifugal Index(Index)
COMMERCIAL RANGE SETS - CENTRIFUGAL
110
ART FLUX 360º CASSETTE SUPERSLIM
TECHNICAL SPECIFICATIONS
*Sound pressure at low speed.
**Factory pre-charge for 5 metres installations / Additional charge per metre added after 5 metres.
Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
SET KCISC-140 DTN10 KCISC-160 DTN10Cooling capacity kW 12.6 16.11
Cooling capacity Kcal/h 10836 13855
Cooling input kW 5.49 6.76
EER 2.29 2.38
Cooling energy class F F
Heating capacity kW 12.89 16.99
Heating capacity Kcal/h 11085 14611
Heating input kW 4.67 6.13
COP 2.75 2.76
Heating efficiency class E E
Heating capacity -7ºC kW 9 11
COP -7ºC 2.16 2.14
OUTDOOR UNIT KUEC-140 DTN10 KUEC-160 DTN10Compressor type Scroll Scroll
Outdoor airflow/Static pressure m3/h / Pa 3600/60 3600/60
Sound pressure dB (A) 64 64
Refrigerant R-410 A R-410 A
Refrigerant charge / Additional charge** gr 4300/30 4300/30
Liquid pipe diameter mm (inch") ø9.52 (3/8") ø9.52 (3/8")
Gas pipe diameter mm (inch") ø15.9 (5/8") ø15.9 (5/8")
Max. piping length m 65 65
Pipe height difference m 30 30
Width/Height/Depth mm 1394/568/783 1394/568/783
Net weight Kg 177 177
Power cord (10 m max.) mm2 (4+T)x4 (4+T)x4
Shielded communication wires mm2 2x1.5 2x1.5
Power supply V / F / Hz 380-400/3/50 380-400/3/50
INDOOR UNIT KCIS-140 DN10 KCIS-160 DN10Indoor airflow m3/h 1850/1600/1400 1900/1650/1450
Sound pressure* dB (A) 48 46
Width/Height/Depth mm 840/287/840 840/287/840
Net weight Kg 28 31
Width/Height/Depth (panel) mm 950/55/950 950/55/950
Net weight (panel) Kg 5 5
Power cord mm2 (2+T)x2.5 (2+T)x2.5
Shielded communication wires mm2 2x1.5 2x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50
Go back to General Contents (Index) Go back to ZEN centrifugal Index
Design and Install for you
111
ZE
N
CEN
TRIF
UGA
L CO
MM
ERCI
AL
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you should add to the € price for the set the price
difference between recommended controller and the selected controller.
CONTROLLERS
KAYSUN UK centrifugal outdoor units are also compatible with the ArtFlux 360° SuperSlim Cassette units. In order to provide users with maximum comfort, the cassette units are fitted with a 360° air diffusion system that allows them to reach every corner of the room. They have an impeccable appearance, a compact structure and a slim design to adapt to spaces with low ceilings.
• Fresh air inlet (optional).
• Standard condensation pump.
• Louvres position memory.
• KC-03 SPS controller, for independent vane control.
• Slim design compact unit.
• Voltage-free Alarm and ON/OFF dry contacts.
• 360º airflow.
• Side air outlet for a duct (optional).
GENERAL CHARACTERISTICS
K01-LON K02-MODBUS K01-BACNET K01-KNXKAYNET CONTROL K01-WIFI
BMS AND SOFTWARE
INDIVIDUAL
For further information, please see our Controllers range
CENTRALISED
KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB
KID-02 S(*) RECOMMENDED
KID-02 S KC-03 SPS
TWINS COMBINATIONS (OPTIONAL)+
STANDARD CONDENSATION PUMP+
OPTIONALMOTORIZED PANEL
If you want the motorised panel
you will also need the KC-03 SPS control
ELIGE TU CONTROL
CHOOSE YOUR CONTROL
PRICE LIST
MOD. SET MOD. INDOORINDOOR UNIT
PRICEMOD. OUTDOOR
OUTDOOR UNIT PRICE
RECOM. CONTROL SET PRICE
KCISC-140 DTN10 KCIS-140 DN10 £814 KUEC-140 DTN10 £3,339 KID-02 S £4,154
KCISC-160 DTN10 KCIS-160 DN10 £851 KUEC-160 DTN10 £3,525 KID-02 S £4,377
(*) Price calculation based on the recommended controller.
Go back to General Contents Go back to ZEN centrifugal Index(Index)
COMMERCIAL RANGE SETS - CENTRIFUGAL
112
OUTDOOR UNIT KUEC-140 DTN10 KUEC-160 DTN10Compressor type Scroll Scroll
Outdoor airflow/Static pressure m3/h / Pa 3600/60 3600/60
Sound pressure dB (A) 64 64
Refrigerant R-410 A R-410 A
Refrigerant charge / Additional charge** gr 4300 / 30 4300 / 30
Liquid pipe diameter mm (inch") ø9.52 (3/8") ø9.52 (3/8")
Gas pipe diameter mm (inch") ø15.9 (5/8") ø15.9 (5/8")
Max. piping length m 65 65
Pipe height difference m 30 30
Width/Height/Depth mm 1394/568/783 1394/568/783
Net weight Kg 177 177
Power cord (10 m max.) mm2 (4+T)x4 (4+T)x4
Shielded communication wires mm2 2x1.5 2x1.5
Power supply V / F / Hz 380-400/3/50 380-400/3/50
CEILING/FLOORTECHNICAL SPECIFICATIONS
SET KPCC-140 DTN10 KPCC-160 DTN10Cooling capacity kW 13.5 16
Cooling capacity Kcal/h 11610 13760
Cooling input kW 5.885 6.891
EER 2.29 2.32
Cooling energy class F F
Heating capacity kW 14.65 17
Heating capacity Kcal/h 12599 14620
Heating input kW 5.657 6.468
COP 2.58 2.62
Heating efficiency class F E
Heating capacity -7ºC kW 9.82 10.88
COP -7ºC 2.00 2.00
INDOOR UNIT KPC-140 DN10 KPC-160 DN10Indoor airflow m3/h 2100/1800/1400 2250/1660/1280
Sound pressure* dB (A) 41 45
Width/height/depth (ceiling installation) mm 1650/235/675 1650/235/675
Net weight Kg 38.2 40.5
Power cord mm2 (2+T)x2.5 (2+T)x2.5
Shielded communication wires mm2 2x1.5 2x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50
*Sound pressure at low speed.
**Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres.
Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
Go back to General Contents (Index) Go back to ZEN centrifugal Index
Design and Install for you
113
ZE
N
CEN
TRIF
UGA
L CO
MM
ERCI
AL
GENERAL CHARACTERISTICS
KAYSUN UK Zen range makes air conditioning at your disposal through its most versatile product, the Ceiling/Floor units. Compact and state-of-the-art design that integrates into every room environment. A simple and, at the same time, versatile unit compatible with centrifugal outdoor units.
• Easy access to components for maintenance.
• FLOOR or CEILING installation.
• New numerical display in the receiver.
• Improved airflow for a greater comfort.
• Voltage-free Alarm and ON/OFF dry contacts.
• KC-03 SPS wired controller (optional).
ALARM AND VOLTAGE-FREE CONTACTS +
CEILING/FLOOR COMPATIBLE +
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you shall add to the € price for the set, the price
difference between the recommended controller and the selected controller.
CONTROLLERS
BMS AND SOFTWARE
INDIVIDUAL
For further information, please see our Controllers range
CENTRALISED
KCT-02.1 SRKC-02.1 H KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB
K01-LON K02-MODBUS K01-BACNET K01-KNXKAYNET CONTROL K01-WIFI
KID-02 S(*) RECOMMENDED
KC-03 SPSKID-02 S
Enquire about availability and price.
KC-01 S
ELIGE TU CONTROL
CHOOSE YOUR CONTROL
PRICE LIST
MOD. SET MOD. INDOORINDOOR UNIT
PRICEMOD. OUTDOOR
OUTDOOR UNIT PRICE
RECOM. CONTROL SET PRICE
KPCC-140 DTN10 KPC-140 DN10 £755 KUEC-140 DTN10 £3,339.95 KID-02 S £4,095
KPCC-160 DTN10 KPC-160 DN10 £769 KUEC-160 DTN10 £3,525.37 KID-02 S £4,294
(*) Price calculation based on the recommended controller.
Go back to General Contents Go back to ZEN centrifugal Index(Index)
COMMERCIAL RANGE SETS - CENTRIFUGAL
114
DUCTSTECHNICAL SPECIFICATIONS
OUTDOOR UNIT KUEC-140 DTN10 KUEC-160 DTN10Compressor type Scroll Scroll
Outdoor airflow/Static pressure m3/h / Pa 3600/60 3600/60
Sound pressure dB (A) 64 64
Refrigerant R-410 A R-410 A
Refrigerant charge / Additional charge** gr 4300/30 4300/30
Liquid pipe diameter mm (inch") ø9.52 (3/8") ø9.52 (3/8")
Gas pipe diameter mm (inch") ø15.9 (5/8") ø15.9 (5/8")
Max. piping length m 65 65
Pipe height difference m 30 30
Width/Height/Depth mm 1394/568/783 1394/568/783
Net weight Kg 177 177
Power cord (10 m max.) mm2 (4+T)x4 (4+T)x4
Shielded communication wires mm2 2x1.5 2x1.5
Power supply V / F / Hz 380-400/3/50 380-400/3/50
SET KPDC-140 DTN10 KPDC-160 DTN10Cooling capacity kW 13.5 16
Cooling capacity Kcal/h 11610 13760
Cooling input kW 5.483 6.281
EER 2.46 2.54
Cooling energy class E E
Heating capacity kW 14.65 17
Heating capacity Kcal/h 12599 14620
Heating input kW 4.962 5.775
COP 2.95 2.94
Heating efficiency class D D
Heating capacity -7ºC kW 10 12
COP -7ºC 2.31 2.29
INDOOR UNIT KPD-140 DN10 KPD-160 DN10Indoor airflow m3/h 2200/1900/1600 2200/1900/1600
Static pressure range (rated) Pa 0-100 (80) 0-100 (80)
Sound pressure* dB (A) 45 45
Width/Height/Depth mm 1200/300/865 1200/300/865
Net weight Kg 43.2 43.1
Power cord mm2 (2+T)x2.5 (2+T)x2.5
Shielded communication wires mm2 2x1.5 2x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50
*Sound pressure at low speed.
**Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres.
Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
Go back to General Contents (Index) Go back to ZEN centrifugal Index
Design and Install for you
115
ZE
N
CEN
TRIF
UGA
L CO
MM
ERCI
AL
Compatible con
KAYSUN UK ducts units offer a wide range of features, which turns them into one of the best products in the market. These units can be easily installed in small spaces, such as compact suspended ceilings, thanks to the tilted position of their battery, which provides them with a slim design. They are compatible with KAYSUN UK centrifugal outdoor units.
• Easily removable filter.
• Air supply duct and return air duct pre-installation frames.
• Double possibility for air inlet (rear or lower intake).
• Fresh air intake on the side of the unit.
• Voltage-free alarm and ON/OFF dry contacts.
• Electric box removable up to 1 metre apart from the unit's body.
• Up to 100 Pa available depending on the model.
• Standard condensation pump of up to 750 mm in height.
GENERAL CHARACTERISTICS
STANDARD CONDENSATION PUMP, up to 750 mm IN HEIGHT+ALARM AND VOLTAGE-FREE CONTACTS +
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you should add to the € price for the set the price
difference between recommended controller and the selected controller.CONTROLLERS
BMS AND SOFTWARE
INDIVIDUAL
For further information, please see our Controllers range
CENTRALISED
KCT-02.1 SRKC-02.1 H KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB
K01-LON K02-MODBUS K01-BACNET K01-KNXKAYNET CONTROL K01-WIFI
KID-02 S KC-03 SPS
KC-03 SPS
(*) RECOMMENDED
Enquire about availability and price.
KC-01 S
ELIGE TU CONTROL
CHOOSE YOUR CONTROL
PRICE LIST
MOD. SET MOD. INDOORINDOOR UNIT
PRICEMOD. OUTDOOR
OUTDOOR UNIT PRICE
RECOM. CONTROL SET PRICE
KPDC-140 DTN10 KPD-140 DN10 £681 KUEC-140 DTN10 £3,339 KC-03 SPS £4,021
KPDC-160 DTN10 KPD-160 DN10 £718 KUEC-160 DTN10 £3,525 KC-03 SPS £4,244
(*) Price calculation based on the recommended controller.
Go back to General Contents Go back to ZEN centrifugal Index(Index)
COMMERCIAL RANGE
116
GRAPHICS OF DUCT CENTRIFUGAL
DUCTS STATIC PRESSURE GRAPHS
KPD-140 DN10
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
High Medium Low
Airflow (m3/h) Airflow (m3/h) Airflow (m3/h)
Go back to General Contents (Index) Go back to ZEN centrifugal Index
Design and Install for you
117
ZE
N
CEN
TRIF
UGA
L CO
MM
ERCI
AL
Airflow (m3/h) Airflow (m3/h) Airflow (m3/h)
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
Ext
erna
l sta
tic
pres
sure
(Pa)
KPD-160 DN10
High Medium Low
Go back to General Contents Go back to ZEN centrifugal Index(Index)
COMMERCIAL RANGE
118
TWINS
TWINS
The balance of the KAYSUN UK ZEN range results in a good service and comfort for the user and makes life easier for installers. Commercial range units are fitted with a specific electronic board that allows for connecting two indoor units to the same outdoor unit.
The TWIN technology in centrifuges can be applied to the Art Flux 360º Super Slim Cassette, duct units and ceiling/floor units.
Furthermore, sets of different indoor units can be made for example, a duct unit can be combined with a ceiling/floor type
unit, among many other possibilities, provided that both indoor units are the same capacity. The capacities with which you can arrange Twins combinations are the following:
- Outdoor unit of 14kW with two indoor units of 7.1kW- Outdoor unit of 16kW with two indoor units of 9.0kW
Twins represent the versatility and balance of the Zen range, and are presented as an option for commercial spaces that require more than one indoor unit to achieve a suitable air-conditioning without requiring more outdoor units.
PIPE DISTANCE
Maximum distance (L+L1+L2)
71+71 indoor combination (A+B) 65 m.
90+90 indoor combination (A+B) 65 m.
Maximum distance between the branch pipe and the indoor unit (L1 and L2) 15 m.
Maximum difference in length between the branch pipe and the indoor units (L1-L2) 10 m.
LEVEL DIFFERENCEBetween outdoor unit and indoor units 20 m.
Between indoor units (A and B) 0.5 m.
UNIT BUNIT A
OUTDOOR UNIT
L
L1 L2
DIFFERENT TYPES OF INDOOR UNIT CAN BE COMBINEDIn Twins sets, one can choose from two types of indoor unit. You can create your Twin set by combining the 2 indoor units that suit you best, provided that they have the same capacity.
Maximum height difference between indoor units of a TWIN system: 0.5 metresBranch pipe not included. Add T-type branch pipe or KCMI 112 branch pipe
OUTDOOR UNIT
SuperSlim cassetteDuct
Ceiling/floor
CONTROL
KID-02 SKC-03 SPS
SuperSlim cassetteDuct
Ceiling/floor
INDOOR UNIT INDOOR UNIT
Go back to General Contents (Index) Go back to ZEN centrifugal Index
Design and Install for you
119
ZE
N
CEN
TRIF
UGA
L CO
MM
ERCI
AL
KID-02 S FLOOR / CEILING FLOOR / CEILING
KC-03 SPS DUCTS DUCTS
KID-02 S SUPERSLIM CASSETTE 360º
SUPERSLIM CASSETTE 360º
x2
x2
x2
INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE £
KPC-71 DN10 KUEC-140 DTN10 KID-02 S £4,544
KPC-90 DN10 KUEC-160 DTN10 KID-02 S £4,936
CEILING/FLOOR
SUPERSLIM CASSETTE INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE £
KCIS-71 DN10 KUEC-140 DTN10 KID-02S £4,547
KCIS-90 DN10 KUEC-160 DTN10 KID-02 S £5,053
INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE £
KPD-71 DN10 KUEC-140 DTN10 KC-03 SPS £4,090
KPD-90 DN10 KUEC-160 DTN10 KC-03 SPS £4,616
DUCTS
Go back to General Contents Go back to ZEN centrifugal Index(Index)
Design and Install for you
121
INTRODUCTION TO THE PRODUCT RANGE ....................................... ..122
HIGH-CAPACITY SETS OF DUCTS ....................................................... ..123
AIR-COOLED..................................................................................... ..124
WATER-COOLED.............................................................................. ..128
STATIC PRESSURE GRAPHS ........................................................... ..130
ZENHIGH CAPACITY COMMERCIAL RANGE
COMMERCIAL RANGE
122
We present the high-capacity commercial range. The main characteristics we wish to highlight in this range are its vast cooling capacity and large airflows. These machines are ideal for climate control in large spaces.
Most of these combinations are equipment with a compressor, outdoor ventilators and indoor ventilators with DC Inverter technology, resulting in efficiency and energy savings.
Basically, we have 6 capacity levels of indoor units that range from 20 to 56 kW, and which can be combined with different types of the outdoor unit: side air discharge, top air discharge and watercooled.
INTRODUCTION TO THE RANGE OF PRODUCTS
HIGH CAPACITY COMMERCIAL RANGE
ZEN
“HIGH-PERFORMANCE COMMERCIAL EQUIPMENT”
SIDE AIR DISCHARGE TOP AIR DISCHARGE WATERCOOLED
STATIC PRESSURE OF UP TO 200 PA+LARGE AIRFLOWS+
OUTDOOR UNITS
The high-capacity commercial range contains three different types of outdoor unit, ensuring perfect adaptability to each different type of installation:
LITTLE INSTALLATION SPACE+ EXTREMELY COMPACT+STATIC PRESSURE AVAILABLE 40 PA+ACTUAL LENGTH OF UP TO 175 METRES+TWIN ROTARY COMPRESSORS+ INDOOR INSTALLATION+
LARGE AIRFLOWS
Duct units in the high-capacity commercial range are made up of indoor units of ducts with large airflows at high static pressure levels.
Go back to General Contents Go back to ZEN high capacity Index(Index)
Design and Install for you
123
ZE
N
HIG
H C
APA
CITY
CO
MM
ERCI
AL
20.0 25.0 28.0 40.0 45.0 56.0POWER kW
AIRCOOLED SIDE AIR DISCHARGE
AIRCOOLED TOP AIR DISCHARGE
WATERCOOLED
KPDHF-200F DN3.0 KPDHF-250F DN3.0
KPDHF-280V DN3.0
KPDHFW-280 DN3.0
KPDHF-280F DN3.0
KPDHF-400V DN2.4
KPDHF-400F DN2.4 KPDHF-450F DN2.4
KPDHF-450V DN2.4
KPDHFW-250 DN3.0
KPDHF-560V DN2.4
KPDHFW-560 DN2.4
SETS
Go back to General Contents Go back to ZEN high capacity Index(Index)
COMMERCIAL RANGE HIGH CAPACITY - AIRCOOLED
124
HIGH CAPACITY DUCTS AIRCOOLED
TECHNICAL SPECIFICATIONS
Working range 200/260: -15ºC to 48ºC (Cooling) / -20ºC to 27ºC (Heating)
K2UF working range: -15ºC to 48ºC (Cooling) / -20ºC to 27ºC (Heating)
OUTDOOR UNIT KMF-200 DN2 KMF-260 DN2 KMF-260 DN2 K2UF-280 DN3Compressor type Double rotary Double rotary Double rotary Scroll Inv.
Outdoor airflow m3/h 10999 10494 10494 11000
Static Pressure Pa No No No 40
Sound pressure dB (A) 59 60 60 57
Refrigerant R-410 A R-410 A R-410 A R-410 A
Refrigerant volume gr 4800 6200 6200 10000
Liquid pipe diameter mm (inch) ø9.52 (3/8") ø12.7 (1/2”) ø19.52 (3/8") ø112.7 (1/2")
Gas pipe diameter mm (inch) ø19.1 (3/4") ø22.2 (7/8") ø122.2 (7/8") ø122.2 (7/8")
Max. piping length m 60 60 60 150
Pipe height difference m 30 30 30 70
Width/Height/Depth mm 1120/1558/528 1120/1558/528 1120/1558/528 960/1615/765
Net weight Kg 137 147 147 245
Power cord (Max. 10 m) mm2 (4+T)x4 (4+T)x4 (4+T)x4 (4+T)x6
Communication wiring mm2 3x1.5 3x1.5 3x1.5 3x1.5
Power supply V / F / Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50
SET KPDHF-200F DN3.0 KPDHF-250F DN3.0 KPDHF-280F DN3.0 KPDHF-280V DN3.0Cooling capacity (min./rated/max.) kW 10.0/20.0/21.1 13.0/25.0/27.5 13.0/26.1/27.5 14.0/28.0/29.6
Cooling capacity (min./rated/max.) Kcal/h 8600/17200/18146 11180/21500/23650 11180/22446/23650 12040/24080/25456
Cooling input W 7610 9015 9110 8710
SEER 6.19 6.42 6.42 6.83
Cooling energy class A++ A++ A++ A++
Heating capacity (min./rated/max.) kW 11.0/22.0/26.1 14.3/27.0/33.7 14.3/28.5/33.7 15.8/31.5/37.3
Heating capacity (min./rated/max.) Kcal/h 9460/18920/22446 12298/23220/28982 12298/24510/28982 13588/27090/32078
Heating input W 7610 8255 8310 9120
SCOP 3.76 4.05 4.05 5.94
Heating efficiency class A A+ A+ A+++
INDOOR UNIT KPDHF-200 DN3.0 KPDHF-250 DN3.0 KPDHF-280 DN3.0 KPDHF-280 DN3.0Indoor airflow m3/h 4800/3900/3500 4600/4000/3600 4600/4000/3600 4600/4000/3600
Static pressure range (rated) Pa 0-200 (120) 0-200 (120) 0-200 (120) 0-200 (120)
Sound pressure (low speed) dB (A) 50 50 50 50
Width/Height/Depth mm 1443/470/810 1443/470/810 1443/470/810 1443/470/810
Net weight Kg 108 108 108 108
Power cord mm2 (2+T)x4 (2+T)x4 (2+T)x4 (2+T)x4
Communication wiring mm2 3x1.5 3x1.5 3x1.5 3x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
Go back to General Contents Go back to ZEN high capacity Index(Index)
Design and Install for you
125
ZE
N
HIG
H C
APA
CITY
CO
MM
ERCI
AL
GENERAL CHARACTERISTICS
CONTROLLERS
BMS AND SOFTWARE
INDIVIDUAL
For further information, please see our Controllers range
CENTRALISED
KCT-02.1 SR KC-02.1 H KCC-16 KCCT-64 IKCC-64 WEB
K01-LON K02-MODBUS K01-BACNET K01-KNX KAYNET CONTROLK01-WIFI
KI-02.3 S
KCT-02.1 SR
TEMPERATURE ADJUSTMENT / GREATER COMFORT +VOLTAGE-FREE DRY CONTACTS+
(*) RECOMMENDED
KAYSUN UK high-pressure ducts have a higher static pressure to cover long distances, which provides greater installation flexibility and accurate air conditioning, even in rooms with high ceilings.
• Refrigerant expansion system into the indoor unit.
• Available static pressure up to 200 Pa.
• Voltage-free ON/OFF dry contact.
• 220V signal output alarm.
• Indoor units 200, 250 and 280 are fitted with DC fan motor.
KCC-64 I-PS
K2UF
KMF
KC-01 S
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you should add to the € price for the set the price
difference between recommended controller and the selected controller.ELIGE TU CONTROL
CHOOSE YOUR CONTROL
PRICE LISTSET MODEL INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE
KPDHF-200F DN3.0 KPDHF-200 DN3.0 KMF-200 DN2 KCT-02.1 SR £4,638
KPDHF-250F DN3.0 KPDHF-250 DN3.0 KMF-260 DN2 KCT-02.1 SR £5,241
KPDHF-280F DN3.0 KPDHF-280 DN3.0 KMF-260 DN2 KCT-02.1 SR £5,271
KPDHF-280V DN3.0 KPDHF-280 DN3.0 K2UF-280 DN3 KCT-02.1 SR £6,050
(*) Price calculation based on the recommended controller.
Go back to General Contents Go back to ZEN high capacity Index(Index)
COMMERCIAL RANGE HIGH CAPACITY - AIRCOOLED
126
HIGH CAPACITY DUCTS AIRCOOLED
TECHNICAL SPECIFICATIONS
OUTDOOR UNIT KMF-400 DN3
KMF-450 DN3
K2UF-400 DN3
K2UF-450 DN3
K2UF-560 DN3
Compressor type Double rotary (2) Double rotary (2) Scroll Inverter + Fixed Scroll (2)
Scroll Inverter + Fixed Scroll (2)
Scroll Inverter + Fixed Scroll (2)
Outdoor airflow m3/h 16575 16575 15000 15000 18000
Static Pressure Pa No No 40 40 40
Sound pressure dB (A) 62 62 60 60 62
Refrigerant type R-410 A R-410 A R-410 A R-410 A R-410 A
Refrigerant factory charge gr 9000 12000 15000 15000 17000
Liquid pipe diameter mm (inch) ø12.7 (1/2”) ø12.7 (1/2”) ø12.7 (1/2”) ø12.7 (1/2”) ø15.9 (5/8")
Gas pipe diameter mm (inch) ø28.6 (1 1/8") ø28.6 (1 1/8") ø28.6 (1 1/8") ø28.6 (1 1/8") ø28.6 (1 1/8")
Max. piping length m 120 120 175 175 200
Pipe height difference m 30 30 70 70 110
Width/Height/Depth mm 1360/1650/540 1460/1650/540 1250/1615/765 1250/1615/765 1390/1615/765
Net weight Kg 240 275 325 325 360
Power cord (10 m max.) mm2 (4+T)x16 (4+T)x16 (4+T)x10 (4+T)x10 (4+T)x16
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5
Power supply V / F / Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50
SET KPDHF-400F DN2.4
KPDHF-450F DN2.4
KPDHF-400V DN2.4
KPDHF-450V DN2.4
KPDHF-560V DN2.4
Cooling capacity (min./rated/max.) kW 20.0/40.0/42.3 22.5/45.0/47.6 20.0/40.0/42.3 22.5/45.0/47.6 28.0/56.0/59.2
Cooling capacity (min./rated/max.) Kcal/h 17200/34400/
3637819350/38700/
40936 17200/34400/
36378 19350/38700/
40936 24080/48160/
50912
Cooling input W 14300 16300 15000 16710 20400
SEER 6.26 6.2 6.18 6.05 6.22
Cooling energy class A++ A++ A++ A++ A++
Heating capacity (min./rated/max.) kW 22.5/45.0/53.3 25.0/50.0/59.2 22.5/45.0/53.3 25.0/50.0/59.2 31.5/63.0/74.6
Heating capacity (min./rated/max.) Kcal/h 19350/38700/
45838 21500/43000/
5091219350/38700/
4583821500/43000/
5091227090/54180/
64156
Heating input W 13800 15400 13890 15480 19400
SCOP 5.33 5.2 5.52 5.29 5.32
Heating efficiency class A+++ A+++ A+++ A+++ A+++
INDOOR UNIT KPDHF-400 DN2.4
KPDHF-450 DN2.4
KPDHF-400 DN2.4
KPDHF-450 DN2.4
KPDHF-560 DN2.4
Indoor airflow m3/h 7700/6400/5200 7700/6400/5200 7700/6400/5200 7700/6400/5200 10100/8400/7000
Static pressure range (rated) Pa 0-200(125) 0-200(125) 0-200(125) 0-200(125) 0-200(125)
Sound pressure (low speed) dB (A) 56 56 56 56 57
Width/Height/Depth mm 1970/668/903 1970/668/903 1970/668/903 1970/668/903 1970/668/903
Net weight Kg 232 232 232 232 235
Power cord mm2 (2+T)x4 (2+T)x4 (2+T)x4 (2+T)x4 (2+T)x4
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
K2UF working range: -15ºC to 48ºC (Cooling) / -20ºC to 27ºC (Heating)
KMF-400/450 working rate: -15ºC to 48ºC (Cooling) / -15ºC to 24ºC (Heating)
Go back to General Contents Go back to ZEN high capacity Index(Index)
Design and Install for you
127
ZE
N
HIG
H C
APA
CITY
CO
MM
ERCI
AL
GENERAL CHARACTERISTICS
KAYSUN UK high-pressure ducts have a higher static pressure to cover long distances, which provides greater installation flexibility and accurate air conditioning, even in rooms with high ceilings.
• Refrigerant expansion system into the indoor unit.
• Available pressure up to 200 Pa.
• Filter is not included in 400, 450 and 560 units.
• Voltage-free ON/OFF dry contact.
• 220V signal output alarm.
CONTROLLERS
INDIVIDUAL
For further information, please see our Controllers range
CENTRALISED
KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB
BMS AND SOFTWARE
K01-LON K02-MODBUS K01-BACNET K01-KNXKAYNET CONTROL K01-WIFI
KCT-02.1 SR KC-02.1 HKI-02.3 S
KCT-02.1 SR
TEMPERATURE ADJUSTMENT / GREATER COMFORT +VOLTAGE-FREE DRY CONTACTS+
(*) RECOMMENDED
K2UF
KMF
KC-01 S
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you should add to the € price for the set the price
difference between recommended controller and the selected controller.ELIGE TU CONTROL
CHOOSE YOUR CONTROL
PRICE LISTSET MODEL INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE
KPDHF-400F DN2.4 KPDHF-400 DN2.4 KMF-400 DN3 KCT-02.1 SR £8,193
KPDHF-450F DN2.4 KPDHF-450 DN2.4 KMF-450 DN3 KCT-02.1 SR £8,947
KPDHF-400V DN2.4 KPDHF-400 DN2.4 K2UF-400 DN3 KCT-02.1 SR £9,112
KPDHF-450V DN2.4 KPDHF-450 DN2.4 K2UF-450 DN3 KCT-02.1 SR £9,578
KPDHF-560V DN2.4 KPDHF-560 DN2.4 K2UF-560 DN3 KCT-02.1 SR £11,405
(*) Price calculation based on the recommended controller.
Go back to General Contents Go back to ZEN high capacity Index(Index)
COMMERCIAL RANGE
128
HIGH CAPACITY - WATERCOOLED
HIGH CAPACITY DUCTS WATERCOOLED
TECHNICAL SPECIFICATIONS
OUTDOOR UNIT K2F-252 DN3W K2F-280 DN3W K2F-560 DN3WNo. of outdoor modules 1 1 2**
Models K2F-252 DN3W K2F-280 DN3W K2F-280 DN3W K2F-280 DN3W
Compressor type Scroll Inverter Scroll Inverter Scroll Inverter Scroll Inverter
Sound pressure dB (A) 51 52 52 52
Refrigerant type R-410 A R-410 A R-410 A R-410 A
Refrigerant factory charge gr 2000 2000 2000 2000
Liquid pipe diameter mm (inch") ø9.52 (3/8") ø12.7 (1/2”) ø15.9 (5/8")
Gas pipe diameter mm (inch") ø19.1 (3/4") ø22.2 (7/8") ø28.6 (1 1/8")
Max. piping length m 150 150 150
Pipe height difference m 50 50 50
Width/Height/Depth mm 780/1000/550 780/1000/550 780/1000/550 780/1000/550
Net weight Kg 146 146 146 146
Power cord (10 m max.) mm2 (4+T)x4 (4+T)x6 (4+T)x6 (4+T)x6
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5
Power supply V / F / Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50
SET KPDHFW-250 DN3.0 KPDHFW-280 DN3.0 KPDHFW-560 DN2.4Cooling capacity (min./rated/max.) kW 12.6/25.2/26.6 14.1/28.0/29.6 14.1/56.0/59.2
Cooling capacity (min./rated/max.) Kcal/h 10836/21672/22876 12126/24080/25456 12126/48160/50912
Cooling input W 6310 7610 15600
Heating capacity (min./rated/max.) kW 14.5/27.0/28.2 17.0/31.5/32.9 17.0/63.0/65.8
Heating capacity (min./rated/max.) Kcal/h 12470/23220/24252 14620/27090/28294 14620/54180/56588
Heating input W 5960 7340 15060
INDOOR UNIT KPDHF-250 DN3.0 KPDHF-280 DN3.0 KPDHF-560 DN2.4Indoor airflow m3/h 4600/4000/3600 4600/4000/3600 10100/8400/7000
Static pressure range (rated) Pa 0-200 (120) 0-200 (120) 0-200(125)
Sound pressure* dB (A) 50 50 57
Width/Height/Depth mm 1443/470/810 1443/470/810 1970/668/903
Net weight Kg 108 108 235
Power cord mm2 (2+T)x4 (2+T)x4 (2+T)x4
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50
*Sound pressure at low speed.
**KCME is required to attach outdoor modules to form the unit
Go back to General Contents Go back to ZEN high capacity Index(Index)
Design and Install for you
129
ZE
N
HIG
H C
APA
CITY
CO
MM
ERCI
AL
KCT-02.1 SR
GENERAL CHARACTERISTICS
KAYSUN UK high-pressure ducts have a higher static pressure to cover long distances, which provides greater installation flexibility and accurate air conditioning, even in rooms with high ceilings.
• Refrigerant expansion system into the indoor unit.
• Available pressure up to 200 Pa.
• 560 units do not include filter.
• Voltage-free ON/OFF dry contact.
• 220V signal output alarm.
• Indoor units 200, 250 and 280 are fitted with Dc fan motor.
TEMPERATURE ADJUSTMENT / GREATER COMFORT +VOLTAGE-FREE DRY CONTACTS+
CONTROLLERS
BMS AND SOFTWARE
INDIVIDUAL
For further information, please see our Controllers range
CENTRALISED
KCT-02.1 SRKC-02.1 H KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEBKI-02.3 S
CONDENSED BY WATER +
K01-LON K02-MODBUS K01-BACNET K01-KNXKAYNET CONTROL K01-WIFI
(*) RECOMMENDED
KC-01 S
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you should add to the € price for the set the price
difference between recommended controller and the selected controller.ELIGE TU CONTROL
CHOOSE YOUR CONTROL
PRICE LISTSET MODEL INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE
KPDHFW-250 DN3.0 KPDHF-250 DN3.0 K2F-252 DN3W KCT-02.1 SR £6,906
KPDHFW-280 DN3.0 KPDHF-280 DN3.0 K2F-280 DN3W KCT-02.1 SR £7,564
KPDHFW-560 DN2.4 KPDHF-560 DN2.4 K2F-560 DN3W KCT-02.1 SR £14,942
(*) Price calculation based on the recommended controller.
Go back to General Contents Go back to ZEN high capacity Index(Index)
COMMERCIAL RANGE
130
HIGH CAPACITY STATIC PRESSURE GRAPHS
HIGH CAPACITY DUCTS STATIC PRESSURE GRAPHS
KPDHF-200 DN3.0
KPDHF-250 (280) DN3.0
Go back to General Contents Go back to ZEN high capacity Index(Index)
Design and Install for you
131
ZE
N
HIG
H C
APA
CITY
CO
MM
ERCI
AL
KPDHF-400(450) DN 2.4
KPDHF-560 DN 2.4
56KW/h (50Hz)
Go back to General Contents Go back to ZEN high capacity Index(Index)
Design and Install for you
133
INTRODUCTION TO THE PRODUCT RANGE .............................................. .134
INDOOR UNITS ..........................................................................................141
WALL ................................................... ..............KAYF.......................143
DOUBLE FLOW CONSOLE .................. ..............KSDF........................145
FLOOR STANDING EXPOSED/CONCEALED......KS(E)F.......................147
CEILING/FLOOR .................................. ...............KPCF.............. ..........149
ONE WAY CASSETTE ......................... ...............KCOF.............. ..........151
ART FLUX 360º (600x600) CASSETTE.............KCIF.............. ...........153
ART FLUX 360º CASSETTE........ ........ ...............KCIF.............. ...........155
DUCTS.................................................. ...............KPDF.............. ......... 157
STATIC PRESSURE GRAPHS ....... ............ ................................... 161
HIGH PRESSURE DUCTS ................... ...............KPDHF ..................... 165
KAHU ................................................... ...............KAHU.............. ........ 169
DOMESTIC HOT WATER RECOVERY KIT............KWF.............. .......... 171
OUTDOOR UNITS ........................................................................................174
2 PIPES ..................................................................................................... 176
MINI AMAZON VRF
SINGLE-PHASE....... ............... ...............KMF DVN2 .............. 178
THREE-PHASE ................................... ...KMF DTN2 .............. 180
AMAZON UNITARIO SIDE AIR DISCHARGE.......KMF ....................... 182
AMAZON UNITARIO TOP AIR DISCHARGE.......K2UF ....................... 184
AMAZON IV PRO ................................ ...............K2F DN4S ............... 186
AMAZON III W .................................... ...............K2F DN3W .............. 188
3 PIPES ...................................................................................................... 190
AMAZON III PRO ................................. ...............K3F DN3S ............... 192
KVB BOXES..................... ....... ...............KVB .........................194
SIZING OF PIPES ....................................................................................... 196
DISTANCES AND HEIGHT DIFFERENCES ...............................................202
AMAZONINDUSTRIAL VRF RANGE
INDUSTRIAL VRF RANGE
134
INTRODUCTION TO THE RANGE OF PRODUCTS
INDUSTRIAL VRF RANGEAMAZONWithin the world of air-conditioning, the variable refrigerant flow systems (VRF) are the most versatile in terms of installation possibilities and technological innovation. Thanks to the DC Inverter technology, which varies the frequency of the compressor motor and fan motor of the outdoor unit depending on the total required load, and thanks to electronic expansion valves (both in the outdoor and the indoor units), which regulate the flow of refrigerant depending on the load required for each area, higher levels of efficiency and superior energy savings are achieved. The installation distances available are among the longest in the market, reaching up to 200 meters of equivalent length between the outdoor unit and the farthest indoor unit.
The possibilities of the indoor units are endless, not only for the different models available, but also for their capacity range, which is so wide that it covers from 1.5 kW to 56 kW
and allows for installing up to 64 indoor units in the same cooling circuit. The independent control of indoor units allows each user to choose its own comfort level without interfering with the rest of users.
Our wide range of controllers provides end-user with many options to define its level of comfort. They allow installing from a simple individual control (wireless or wired), a centralised control, a computer control and even the possibility of managing the installation from a comprehensive building management system BMS (LONWORKS, MODBUS, BACNET and KNX).
“THE BROADEST PRODUCT RANGE ON THE MARKET”
AMAZON UNITARIO SIDE AIR DISCHARGE (2 PIPES)
• DC Inverter fan motors Side air discharge
• DC Inverter compressors
• 40 AND 45 kW• Up to 15 indoor units• Up to 150% simultaneity • Auto-addressing• XYE port to connect a centralised control of indoor units
FOR PIPELINES250 m
COMPACT DESIGN
INSTALLATION SPACE
+
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
135
AM
AZ
ON
IND
US
TRIA
L V
RF
SLIM DESIGN SOFT AIRFLOW
LOW SOUND LEVELS
INTERACTIVE DISPLAY
RENEWED PANEL
AIR INLET DUCT FRAME AND AIR OUTLET DUCT FRAME INCLUDED
REAR/LOWER AIR INLET
STATIC PRESSURE CHANGE (OPTIONAL)
INDOOR UNITS WITH DC INVERTER FAN
Most KAYSUN UK AMAZON indoor units include a DC Inverter motor fan. This development provides units with a much more accurate control, and greater output and energy savings, and it reduces sound (low) pressure.
Our units are better suited to the installation requirements of the areas in need of air conditioning, thereby making users' comfort, well-being and energy savings a top priority.
WALL-MOUNTED
CASSETTE ART FLUX 360º
DUCTS
CEILING/FLOOR
HIGH PRESSURE DUCTSCASSETTE ART FLUX 360º (600x600)
CONDENSATION PUMP
COMPACT UNIT
360° AIRFLOW
360° AIRFLOW DOUBLE INSTALLATION
WIDE POWER RANGE
HIGH AIRFLOW
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
136
INTRODUCTION TO THE RANGE OF PRODUCTS
COMPENSATION TECHNOLOGY FOR HIGH-PERFORMANCE OIL
The design of the Scroll DC Inverter compressor is based on the highest technology available.
With a more compact structure, this compressor provides maximum performances, increases efficiency and reduces power consumption when the system is working at partial loads.
The compressor, which has been optimized for using R410A ecological refrigerant, has received the highest energy classification for both cooling and heating operation - EER and COP.
Speed in DC can be adjusted and results in energy savings of up to 25%, more than any other conventional equipment on the market.
NEW STRUCTURE AND HIGH ENERGY EFFICIENCY AT PARTIAL LOAD
NEW SERRATED DESIGN FOR R410A
50% LIGHTER, THANKS TO ITS DESIGN
THE ELABORATE DESIGN OF THE COMPRESSOR ALLOWS A MORE CENTRALISED MAGNETIC FLOW
IT USES A DC INVERTER MOTOR
CENTRALISED WINDING
The DC Inverter compressor's technology used in KAYSUN's AMAZON units, are fitted with centralised winding instead of distributing winding. This type of winding consists of very powerful magnets that allow for increasing the force of rotation and therefore, the compressor's effectiveness.
EFFECTIVENESS OF THE COMPRESSOR
20 40 60 80 100 ROTOR SPEED(S-1)
Central coil
New DC motor
Dispensing coil
70% Reduction
Common DC motor
EFFECTIVENESS OF THE COMPRESSOR
20 40 60 80 100 ROTOR SPEED(S-1)
Central coil
New DC motor
Dispensing coil
70% Reduction
Common DC motor
HIGH INVERTER TECHNOLOGY
Outdoor units ensure individualised control and homogeneous distribution of oil between modules so that the compressor is able to provide a smooth and reliable performance. The oil balance and outlet pipes send the compressor's remaining oil to a system that will distribute it uniformly to the other compressors.
The oil separator, is capable to work with an efficiency over 99%, by sending oil to the compressors on time and effectively in order to ensure that they have the correct amount of oil. This system is designed to extend the working life of KAYSUN UK units' compressors as much as possible.
DIS
CHA
RG
E PI
PE
HIGH PRESSURE GAS
SUCTION PIPE
high-performanceoil separator 99%
condenser inlet
oil balancing door between modules
OIL
BA
LAN
CIN
G P
IPE
BET
WEE
N
MO
DU
LES
III
from indoor units
OIL CLEARING PIPE II
OILCLEARING
PIPE I
compressor
INLET PIPE
DISCHARGE PIPE
OIL COMPENSATION PIPE
OIL PAN
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
137
AM
AZ
ON
IND
US
TRIA
L V
RF
600
500
400
300
200
100
STARTING FREQUENCY (%)
TIME (SEG)1 2 3 4 5 6
ON/OFF switch Switch Inverter switch
SMART SOFT-STARTER TECHNOLOGY
DC INVERTER compressors characterise by a soft, low frequency and low power consumption starter. This reduces the risk of overloading the power grid and prevents excessive consumption peaks during outdoor unit starting.(*) Comparison between starting with an inverter starter and with a conventional starter.
FLUCTUATION TEMPERATURE (ºC)
TIME (H)
Inverter
ON/OFF
1 2
Our units are extremely quiet and efficient thanks to their DC Inverter fan, which allows for reducing noise level from 2-5 dB (A) and increases the airflow from 1000 to 4000m3/h.
FAN
1000
200
ROTOR SPEED (PPM)
SYSTEM PRESSURE (Pa)
18 LEVELSof speed adjustment
100
80
60
40
20
EFFECTIVENESS (%)
MOTOR SPEED (RPM)
200 1000
Increase 45%
40 Pa
PROPELLER FAN
The new helical shape of the fan's blades supplies a large volume of air whilst reducing vibrations and resistance to a minimum.
DC INVERTER MOTOR
The fan’s DC Inverter motor consumes minimal energy since the fan speed can be regulated depending on the power demand and the operating pressure of the cooling circuit.
OPTIMISED AIRFLOW OUTLET
The efficiency of the fan’s airflow has been improved thanks to the fan’s new design. This, in combination with the DC Inverter motor, allows for a static pressure increase of up to 40 Pa, a pressure loss decrease and a 10% optimization of the airflow.
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
138
INTRODUCTION TO THE RANGE OF PRODUCTS
WORKING RANGE
Thanks to the new DC Inverter technology, the AMAZON range offers increased operability for cooling and heating modes within a much larger working range, thereby ensuring a perfect air-conditioning control during all seasons of the year.
HEAT EXCHANGER OPTIMIZATION
The heat exchanger of the 12, 20 and 22 HP models of AMAZON IV has been optimised to reduce their volume by adding an extra row to its large surface. Besides, the delta-shaped heat exchanger helps to improve subcooling.
OPERATING MODE LOCKING FUNCTION (2 PIPES)
From a switch located at the outdoor unit's electronic board, user may select 6 different operating modes for the cooling system:
1. Heating mode priority (default).2. Cooling mode priority.3. Cooling mode only.4. Heating mode only.5. Unit addressed as no. 63 determines the operating mode.6. Those units with the same operating mode forming a majority shall determine the operation mode of the whole system.
ROTARY AND CONSTANTLY VENTILATED ELECTRICAL BOX
The electrical box of the AMAZON IV units, apart from providing boards' electronic parts with constant ventilation by means of a heat dissipation system, is completely rotary in order to facilitate the access inside the unit.
The outdoor units' design allows for an easy installation and maintenance. The new electrical box includes an inspection window in the main electronic board that allows for a straightforward access from outside the equipment. The compressor is located just opposite the electric box to make access easier when its replacement is required.
EASY INSTALLATION AND MAINTENANCE
* For further information on AMAZON IV for other rang-es, please check temperature tables.
CENTRALISED CONTROLLER WIRING
All AMAZON systems have an XYE port in the outdoor unit, allowing the three wires of the centralised control cable between the indoor units to be dispensed with. This means that it is possible to connect directly to the XYE port.
XYE PORT DE CONNEXION
AUTO-ADDRESS OF THE INDOOR UNITS
There are two address setting options for indoor units:
Automatic: Using the SW6 switch of the outdoor unit (deactivated by default), the outdoor unit automatically distributes the address to the indoor units with no manual adjustment.
Manual: The address of all indoor units can be consulted and modified using the KI-02.3 S wireless controller or the KCT-02.1 SR wired controller.
MODULES AUTOMATIC REDUNDANCY
AMAZON's intelligent control system, defines the boot priority of the module according to the system load, and balances its operating time to optimise reliability and working life of the unit.
Mural no. 1 Mural no. 2
Mural no. 3 Mural no. 4
OUTDOOR UNIT
INDOOR UNITS
SW6 KI-02.3 S controller
48 ºC
-5 ºC -20 ºC
21 ºC
outdoortemp.
outdoortemp.
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
139
AM
AZ
ON
IND
US
TRIA
L V
RF
WORKING RANGE
The AMAZON units have one of the highest energy efficiency ratings in the market, with very high EER and COP scores. Furthermore, since outdoor units are modular, units with the best EER/COP scores can be combined to provide higher energy efficiency in facilities that require large cooling capacity.
4.35
5.09
4.08
4.57 4.21
4.12
4.07
4.03
3.85
3.75
4.15
4.033.74 3.76
3.43
3.25
3.30
3.203.62 3.39
252 280 335 400 450
Amazon IV
Conventional VRF system
EER
CO
P
Amazon IV
Conventional VRF system
POWER
4.00
3.70
4.00
3.94
3.80
3.70
3.40 3.40
3.303.103.003.25
500 560 615
ECODESIGN
KAYSUN UK not only offers the most technologically advanced products of the market, but also makes every single effort to produce them under the strictest ecological standards in order to ensure a minimal negative impact on the environment.
A NOD TO ENVIRONMENT
R-410A REFRIGERANT
The Amazon system uses the environmentally friendly refrigerant R410A, which, in addition to having high efficiency and energy savings it is characterised for being respectful of the ozone layer and helps us to reduce the impact on the environment.
8 / 10 / 12 14 / 16 / 18 / 20 / 22
Energy saving
Ecodesign
92% Recyclable
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
141
POWER RANGE
POWER kW
POWER kW
WALL-MOUNTED
DOUBLE FLOW CONSOLE
FLOOR STANDING EXPOSED/CONCEALED
CASSETTE ART FLUX 360º (600x600)
CASSETTE ART FLUX 360º
DOMESTIC HOT WATER RECOVERY KIT
DUCTS
HIGH PRESSURE DUCTS
CEILING/FLOOR
ONE WAY CASSETTE
KAHU
1.5 2.2 2.8 3.6 4.5 5.6
7.1 9.0 11.2 14.0 16.0
KPDHF-71 DN3.0 KPDHF-90 DN3.0 KPDHF-112 DN3.0
KSDF-45 DN2.3KSDF-28 DN2.3 KSDF-36 DN2.3
KPDHF-140 DN3.0
KAHU-200.2
KCIF-15 DN3.0 KCIF-28(22) DN3.0 KCIF-36 DN3.0 KCIF-45 DN3.0
KPDHF-160 DN3.0
KAYF-22 DN3.0 KAYF-28 DN3.0 KAYF-36 DN3.0 KAYF-45 DN3.0 KAYF-56 DN3.0
KPDF-15 DN3.0 KPDF-22 DN3.0 KPDF-28 DN3.0 KPDF-36 DN3.0 KPDF-45 DN3.0 KPDF-56 DN3.0
KCIFB-56 DN3.0
KPCF-56 DN3.0
KS(E)F-56 DN2.3
KSEF-56 DN2.3
INDOOR UNITS
NEW
NEW
KCOF-22 DN2.4 KCOF-36 DN2.4
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
142
AM
AZ
ON
IND
US
TRIA
L V
RF
7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 18.0
20.0 25.0 28.0 36.0 40.0 45.0 50.0 56.0 60.0
KPDHF-200 DN3.0 KPDHF-250 DN3.0
KAYF-80 DN3.0
KPDHF-280 DN3.0
KAHU-360.2
KPDHF-400 DN2.4 KPDHF-450 DN2.4 KPDHF-560 DN2.4
KAHU-560.2
KPDF-71 DN3.0 KPDF-90 DN3.0KPDF-80 DN3.0 KPDF-112 DN3.0 KPDF-140 DN3.0
KCIFB-71 DN3.0 KCIFB-80 DN3.0 KCIFB-100 DN3.0 KCIB-112 DN3.0 KCIF-140 DN3.0
KWF-140 ACS
KPCF-90 DN3.0 KPCF-140 DN3.0
KS(E)F-80 DN2.3
KCOF-71 DN2.4
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE INDOOR UNITS
143
33
MODEL KAYF-22 DN3.0
KAYF-28 DN3.0
KAYF-36 DN3.0
KAYF-45 DN3.0
KAYF-56 DN3.0
KAYF-80 DN3.0
Cooling capacity kW 2.2 2.8 3.6 4.5 5.6 8
Cooling capacity Kcal/h 1892 2408 3096 3870 4816 6880
Heating capacity kW 2.4 3.2 4 5 6.3 9
Heating capacity Kcal/h 2064 2752 3440 4300 5418 7740
Power input kW 0.008 0.009 0.019 0.019 0.027 0.053
Indoor airflow m3/h 422/393/356 417/370/316 656/573/488 594/507/424 747/648/547 1195/1005/809
Sound pressure* dB (A) 29 29 30 31 34 36
Width/Height/Depth mm 835/280/203 835/280/203 990/315/223 990/315/223 990/315/223 1194/343/262
Net weight Kg 8.4 9.5 11.4 12.8 12.8 17
Liquid pipe diameter mm (inch") ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8") ø9.52 (3/8")
Gas pipe diameter mm (inch") ø12.7 (1/2") ø12.7 (1/2") ø12.7 (1/2") ø12.7 (1/2") ø15.9 (5/8") ø15.9 (5/8")
Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
The main features of our wall-mounted units are a DC INVERTER fan and the smart design of their panel. They include a LED display located at the centre of the unit that provides it with a modern design by using the most advanced technology in the market.
• Low noise level, creating a peaceful and comfortable atmosphere.
• The swing angle of the louvres may reach up to 90º.
• Built-in expansion valve.
• ON/OFF dry contact and 220 V alarm signal output.
• DC INVERTER fan included.
• Left inlet for installation pipes (front view).
TECHNICAL SPECIFICATIONS
WALL-MOUNTED
All AMAZON indoor units accept R-410 A refrigerant.*Sound pressure at low fan speed.
GENERAL CHARACTERISTICS
COMPATIBLE WITH
MINI AMAZON2 PIPES
see pag. 182
AMAZON UNITARIO2 PIPES
see pag. 186
AMAZON III PRO3 PIPES
see pag. 196
AMAZON III W2 PIPES
see pag. 192
AMAZON IV PRO2 PIPES
see pag. 190
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
144
AM
AZ
ON
IND
US
TRIA
L V
RF
KI-02.3 S
(*) RECOMMENDED
CONTROLLERS
KC-02.1 H
For further information, please see our Controllers range
KI-02.3 SKCT-02.1 SR
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you should add to the € price for the set the price
difference between the recommended controller and the selected controller.
LOW SOUND LEVEL +
DC INVERTER FAN+
BMS AND SOFTWARE
CENTRALISEDINDIVIDUAL
KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB
K01-LON K02-MODBUS K01-BACNET KAYNET CONTROL K01-KNX K01-WIFI
KC-01 S
ELIGE TU CONTROL
CHOOSE YOUR CONTROL
PRICE LISTMODEL RECOMMENDED CONTROL PRICE
KAYF-22 DN3.0 KI-02.3 S £413
KAYF-28 DN3.0 KI-02.3 S £437
KAYF-36 DN3.0 KI-02.3 S £447
KAYF-45 DN3.0 KI-02.3 S £526
KAYF-56 DN3.0 KI-02.3 S £559
KAYF-80 DN3.0 KI-02.3 S £681
(*) Price calculation based on the recommended controller.
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE INDOOR UNITS
145
33
With a modern and cutting-edge design, the consoles can be gracefully incorporated into any space. Their reduced depth, provides the unit with an external flexible design that adapts to every installation, from floor standing installations to low wall-mounted installations, without affecting their capacity.
• They reach the selected temperature more quickly by means of four return air inlets and two supply outlets.
• DC Inverter FAN MOTOR.
• Low starting power and precise room temperature adjustment.
• The electronic expansion valve is integrated inside the indoor unit.
DOUBLE FLOW CONSOLE
TECHNICAL SPECIFICATIONS
GENERAL CHARACTERISTICS
MODEL KSDF-28 DN2.3 KSDF-36 DN2.3 KSDF-45 DN2.3
Cooling capacity kW 2.8 3.6 4.5
Cooling capacity Kcal/h 2408 3096 3870
Heating capacity kW 3.2 4 5
Heating capacity Kcal/h 2752 3440 4300
Power input kW 0.025 0.025 0.045
Indoor airflow m3/h 510/430/229 510/430/229 660/512/400
Sound pressure* dB (A) 27 27 36
Width/Height/Depth mm 700/600/210 700/600/210 700/600/210
Net weight Kg 15 15 15
Liquid pipe diameter mm (inch") Ø6.35 (1/4") Ø6.35 (1/4") Ø6.35 (1/4")
Gas pipe diameter mm (inch") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2")
Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50
All AMAZON indoor units accept R-410 A refrigerant.*Sound pressure at low fan speed.
COMPATIBLE WITH
MINI AMAZON2 PIPES
see pag. 182
AMAZON UNITARIO2 PIPES
see pag. 186
AMAZON III PRO3 PIPES
see pag. 196
AMAZON III W2 PIPES
see pag. 192
AMAZON IV PRO2 PIPES
see pag. 190
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
146
AM
AZ
ON
IND
US
TRIA
L V
RF
ACCURATE ROOM TEMP. ADJUSTMENT+
DC INVERTER FAN +
CONTROLLERS
KC-02.1 H
For further information, please see our Controllers range
KCT-02.1 SR
BMS AND SOFTWARE
CENTRALISEDINDIVIDUAL
KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB
K01-LON K01-BACNET KAYNET CONTROL K01-KNX K01-WIFIK02-MODBUS
KI-02.3 S
(*) RECOMMENDED
KI-02.3 SKC-01 S
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you should add to the € price for the set the price
difference between the recommended controller and the selected controller.ELIGE TU CONTROL
CHOOSE YOUR CONTROL
(*) Price calculation based on the recommended controller.
PRICE LISTMODEL RECOMMENDED CONTROL PRICE
KSDF-28 DN2.3 KI-02.3 S £569
KSDF-36 DN2.3 KI-02.3 S £610
KSDF-45 DN2.3 KI-02.3 S £644
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE INDOOR UNITS
147
The streamlined design of this unit, due mainly to its reduced depth, is the perfect solution for saving space and adapting to every installation, from wall-mounted to floor standing, whether totally or partially recessed, thereby gracefully harmonising with the interior design of the room.
• Built-in expansion valve.
• ON/OFF dry contact and 220 V alarm signal output.
• Its 12Pa static pressure helps move air supply.
FLOOR STANDING EXPOSED/CONCEALED
GENERAL CHARACTERISTICS
TECHNICAL SPECIFICATIONS
MODEL KSEF-56 DN2.3 KS(E)F-56 DN2.3 KS(E)F-80 DN2.3
Cooling capacity kW 5.6 5.6 8
Cooling capacity Kcal/h 4816 4816 6880
Heating capacity kW 6.3 6.3 9
Heating capacity Kcal/h 5418 5418 7740
Power input kW 0.088 0.088 0.13
Indoor airflow m3/h 1150/970/830 1150/970/830 1380/1100/870
Sound pressure* dB (A) 31 31 33
Width/Height/Depth CONCEALED mm - 1500/596/225 1500/596/225
Width/Height/Depth EXPOSED mm 1500/544/212 1500/544/212 1500/544/212
Net weight CONCEALED Kg - 42 44
Net weight EXPOSED Kg 41 41 42.5
Liquid pipe diameter mm (inch") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8")
Gas pipe diameter mm (inch") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8")
Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50
All AMAZON indoor units accept R-410 A refrigerant.*Sound pressure at low fan speed.
COMPATIBLE WITH
MINI AMAZON2 PIPES
see pag. 182
AMAZON UNITARIO2 PIPES
see pag. 186
AMAZON III PRO3 PIPES
see pag. 196
AMAZON III W2 PIPES
see pag. 192
AMAZON IV PRO2 PIPES
see pag. 190
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
148
AM
AZ
ON
IND
US
TRIA
L V
RF
CONCEALED EXPOSED
PA STATIC PRESSURE 12
CONTROLLERS
KC-02.1 H
For further information, please see our Controllers range
KCT-02.1 SR
BMS AND SOFTWARE
CENTRALISEDINDIVIDUAL
KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB
K01-LON K01-BACNET KAYNET CONTROL K01-KNX K01-WIFIK02-MODBUS
KI-02.3 S
(*) RECOMMENDED
KI-02.3 SKC-01 S
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you should add to the € price for the set the price
difference between the recommended controller and the selected controller.ELIGE TU CONTROL
CHOOSE YOUR CONTROL
PRICE LISTMODEL RECOMMENDED CONTROL PRICE
KSEF-56 DN2.3 KI-02.3 S £644
KS(E)F-56 DN2.3 KI-02.3 S £644
KS(E)F-80 DN2.3 KI-02.3 S £705
(*) Price calculation based on the recommended controller.
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE INDOOR UNITS
149
CEILING / FLOOR
GENERAL CHARACTERISTICS
Ceiling/Floor VRF indoor unit with DC INVERTER motors. Its compact design helps integrating the unit into every environment. As its name suggests, these units can be installed on the ceiling in horizontal position and on the floor in vertical position. The design of their condensation water tray so permits.
• Built-in expansion valve.
• ON/OFF dry contact and 220 V alarm signal output.
• Smoother airflow with less turbulences. Thanks to the multi blades fan and the design of its louvres, the airflow is softer and more comfortable.
• Indoor units with DC INVERTER fan.
TECHNICAL SPECIFICATIONS
MODEL KPCF-56 DN3.0 KPCF-90 DN3.0 KPCF-140 DN3.0
Cooling capacity kW 5.6 9 14
Cooling capacity Kcal/h 4816 7740 12040
Heating capacity kW 6.3 10 15.5
Heating capacity Kcal/h 5418 8600 13330
Power input kW 0.094 0.126 0.13
Indoor airflow m3/h 930/830/720 1280/1170/1050 1980/1860/1730
Sound pressure* dB (A) 38 40 42
Width/height/depth (floor installation) mm 990/660/203 1280/660/203 1670/680/244
Net weight Kg 27 33.5 49
Liquid pipe diameter mm (inch") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8")
Gas pipe diameter mm (inch") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8")
Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50
All AMAZON indoor units accept R-410 A refrigerant.*Sound pressure at low fan speed.
COMPATIBLE WITH
MINI AMAZON2 PIPES
see pag. 182
AMAZON UNITARIO2 PIPES
see pag. 186
AMAZON III PRO3 PIPES
see pag. 196
AMAZON III W2 PIPES
see pag. 192
AMAZON IV PRO2 PIPES
see pag. 190
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
150
AM
AZ
ON
IND
US
TRIA
L V
RF
DC INVERTER FAN+
CONTROLLERS
KC-02.1 H
For further information, please see our Controllers range
KCT-02.1 SR
BMS AND SOFTWARE
CENTRALISEDINDIVIDUAL
KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB
K01-LON K01-BACNET KAYNET CONTROL K01-KNX K01-WIFIK02-MODBUS
KI-02.3 S
(*) RECOMMENDED
KI-02.3 SKC-01 S
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you should add to the € price for the set the price
difference between the recommended controller and the selected controller.ELIGE TU CONTROL
CHOOSE YOUR CONTROL
PRICE LISTMODEL RECOMMENDED CONTROL PRICE
KPCF-56 DN3.0 KI-02.3 S £619
KPCF-90 DN3.0 KI-02.3 S £770
KPCF-140 DN3.0 KI-02.3 S £838
(*) Price calculation based on the recommended controller.
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE INDOOR UNITS
151
KAYSUN UK One way cassette. Stands at just 153mm in height, depending on the capacity of the unit. It has a compact and light design, making it very easy to install and maintain in any space. These units are perfectly merged with the ceiling, creating a clean and subtle aesthetic.
• The control box is built into the body of the unit. This saves space and allows facilitates maintenance.
• Standard condensation pump.
• It has a very reduced height, making it ideal for very low suspended ceilings.
ONE WAY CASSETTE
TECHNICAL SPECIFICATIONS
GENERAL CHARACTERISTICS
MODEL KCOF-22 DN2.4 KCOF-36 DN2.4 KCOF-71 DN2.4
Cooling capacity kW 2.2 3.6 7.1
Cooling capacity Kcal/h 1892 3096 6106
Heating capacity kW 2.6 4 8
Heating capacity Kcal/h 2236 3440 6880
Power input kW 0.041 0.041 0.055
Indoor airflow m3/h 523/404/275 573/456/315 933/749/592
Sound pressure* dB (A) 30 34 37
Width/Height/Depth mm 1054/153/425 1054/153/425 1275/189/450
Net weight Kg 12.5 13 18.8
Width/Height/Depth (panel) mm 1180/25/465 1180/25/465 1350/25/505
Net weight (panel) Kg 3.5 3.5 4
Liquid pipe diameter mm (inch") Ø6.35 (1/4") Ø6.35 (1/4") Ø12.7 (1/2")
Gas pipe diameter mm (inch") Ø12.7 (1/2") Ø12.7 (1/2") Ø15.9 (5/8")
Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50
NEW
All AMAZON indoor units accept R-410 A refrigerant.*Sound pressure at low fan speed.
COMPATIBLE WITH
MINI AMAZON2 PIPES
see pag. 182
AMAZON UNITARIO2 PIPES
see pag. 186
AMAZON III PRO3 PIPES
see pag. 196
AMAZON III W2 PIPES
see pag. 192
AMAZON IV PRO2 PIPES
see pag. 190
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
152
AM
AZ
ON
IND
US
TRIA
L V
RF
STANDARD CONDENSATION PUMP+UP TO 153 MM IN HEIGHT+
CONTROLLERS
KC-02.1 H
For further information, please see our Controllers range
KCT-02.1 SR
BMS AND SOFTWARE
CENTRALISEDINDIVIDUAL
KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB
K01-LON K01-BACNET KAYNET CONTROL K01-KNX K01-WIFIK02-MODBUS
KI-02.3 S
(*) RECOMMENDED
KI-02.3 S
NEW
KC-01 S
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you should add to the € price for the set the price
difference between the recommended controller and the selected controller.ELIGE TU CONTROL
CHOOSE YOUR CONTROL
PRICE LISTMODEL RECOMMENDED CONTROL PRICE
KCOF-22 DN2.4 KI-02.3 S £634
KCOF-36 DN2.4 KI-02.3 S £770
KCOF-71 DN2.4 KI-02.3 S £899
(*) Price calculation based on the recommended controller.
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE INDOOR UNITS
153
With its new 360º panel and DC INVERTER fan, the Art Flux Cassette unit provides even, fast and far-reaching air-conditioning control, without leaving dead zones. Since the main unit and panel are compact and lighter, less space and equipment are needed to install it. They can be completely integrated into any space, including shallow ceilings, without sticking out.
• ON/OFF dry contact and 220 V alarm signal output.
• Integrated control box inside the unit's body; it saves space and allows for ceiling installation.
• Ducts pre-installation holes, to supply air to adjoining rooms.
• Electronic expansion valve kit on one side of the unit.
• Indoor units with DC INVERTER FAN.
• Fresh air possibility to enter directly into the room through a pre-installation hole located at the unit’s body.
• Standard condensation pump.
ART FLUX 360º (600x600) CASSETTE
GENERAL CHARACTERISTICS
TECHNICAL SPECIFICATIONS
MODEL KCIF-15 DN3.0 KCIF-28(22)DN3.0** KCIF-36 DN3.0 KCIF-45 DN3.0
Cooling capacity kW 1.5 2.8 (2.2) 3.6 4.5
Cooling capacity Kcal/h 1290 2408 (1892) 3096 3870
Heating capacity kW 1.7 3.2 (2.6) 4 5
Heating capacity Kcal/h 1462 2742 (2236) 3440 4300
Power input kW 0.014 0.015 0.021 0.021
Indoor airflow m3/h 526/449/364 522/449/364 604/516/400 604/516/400
Sound pressure* dB (A) 21 22 27 27
Width/Height/Depth mm 570/260/570 570/260/570 570/260/570 570/260/570
Net weight Kg 16 16 17.5 17.5
Width/Height/Depth (panel) mm 648/50/648 648/50/648 648/50/648 648/50/648
Panel net weight Kg 3 3 3 3
Liquid pipe diameter mm (inch") Ø6.35 (1/4") Ø6.35 (1/4") Ø6.35 (1/4") Ø6.35 (1/4")
Gas pipe diameter mm (inch") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2")
Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
All AMAZON indoor units accept R-410 A refrigerant.*Sound pressure at low fan speed.**KCIF-28 DN3.0 model is compatible with KCIF-22 DN3.0 model.
COMPATIBLE WITH
MINI AMAZON2 PIPES
see pag. 182
AMAZON UNITARIO2 PIPES
see pag. 186
AMAZON III PRO3 PIPES
see pag. 196
AMAZON III W2 PIPES
see pag. 192
AMAZON IV PRO2 PIPES
see pag. 190
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
154
AM
AZ
ON
IND
US
TRIA
L V
RF
360º AIR DIFFUSION +
DC INVERTER FAN+
CONTROLLERS
KC-02.1 H
For further information, please see our Controllers range
KCT-02.1 SR
BMS AND SOFTWARE
CENTRALISEDINDIVIDUAL
KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB
K01-LON K01-BACNET KAYNET CONTROL K01-KNX K01-WIFIK02-MODBUS
KI-02.3 S
(*) RECOMMENDED
KI-02.3 SKC-01 S
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you should add to the € price for the set the price
difference between the recommended controller and the selected controller.ELIGE TU CONTROL
CHOOSE YOUR CONTROL
(*) Price calculation based on the recommended controller.
PRICE LISTMODEL RECOMMENDED CONTROL PRICE
KCIF-15 DN3.0 KI-02.3 S £528
KCIF-28(22) DN3.0 KI-02.3 S £558
KCIF-36 DN3.0 KI-02.3 S £586
KCIF-45 DN3.0 KI-02.3 S £647
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE INDOOR UNITS
155
33
33
With its new 360º panel and DC INVERTER fan, the Art Flux Cassette unit provides even, fast and far-reaching air-conditioning control, without leaving dead zones. The unit is so compact and light that it can be integrated into any space, including shallow ceilings, without sticking out.
• Electronic expansion valve kit on one side of the unit.
• ON/OFF dry contact and 220 V alarm signal output.
• Integrated control box inside the unit's body; it saves space and allows for ceiling installation.
• Ducts pre-installation holes, to supply air to adjoining rooms.
• Fresh air possibility to enter directly into the room through a pre-installation hole located at the unit’s body.
• Indoor units with DC INVERTER FAN.
• Standard condensation pump.
CASSETTE ART FLUX 360º
GENERAL CHARACTERISTICS
MODEL KCIBF-56 DN3.0
KCIBF-71 DN3.0
KCIBF-80 DN2.3
KCIBF-100 DN3.0
KCIBF-112 DN3.0
KCIBF-140 DN3.0
Cooling capacity kW 5.6 7.1 8 10 11.2 14
Cooling capacity Kcal/h 4816 6106 6880 8600 9632 12040
Heating capacity kW 6.3 8 9 11 12.5 15
Heating capacity Kcal/h 5418 6880 7740 9460 10750 12900
Power input kW 0.031 0.046 0.048 0.11 0.11 0.12
Indoor airflow m3/h 1029/857/704 1200/996/748 1264/1055/811 1596/1239/1103 1540/1300/1120 1800/1500/1280
Sound pressure* dB (A) 34 34 35 36 36 35
Width/Height/Depth mm 904/230/840 904/230/840 904/230/840 904/300/840 904/300/840 904/300/840
Net weight Kg 24 24 24 27.4 27.4 30
Width/Height/Depth (panel) mm 950/55/950 950/55/950 950/55/950 950/46/950 950/46/950 950/46/950
Panel net weight Kg 5 5 5 5 5 5
Liquid pipe diameter mm (inch") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8")
Gas pipe diameter mm (inch") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8")
Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
All AMAZON indoor units accept R-410 A refrigerant.*Sound pressure at low fan speed.
TECHNICAL SPECIFICATIONS
COMPATIBLE WITH
MINI AMAZON2 PIPES
see pag. 182
AMAZON UNITARIO2 PIPES
see pag. 186
AMAZON III PRO3 PIPES
see pag. 196
AMAZON III W2 PIPES
see pag. 192
AMAZON IV PRO2 PIPES
see pag. 190
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
156
AM
AZ
ON
IND
US
TRIA
L V
RF
CONTROLLERS
KC-02.1 H
For further information, please see our Controllers range
KCT-02.1 SR
BMS AND SOFTWARE
CENTRALISEDINDIVIDUAL
KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB
K01-LON K01-BACNET KAYNET CONTROL K01-KNX K01-WIFI
360º AIR DIFFUSION +
DC INVERTER FAN+
K02-MODBUS
KI-02.3 S
(*) RECOMMENDED
KI-02.3 SKC-01 S
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you should add to the € price for the set the price
difference between the recommended controller and the selected controller.ELIGE TU CONTROL
CHOOSE YOUR CONTROL
PRICE LIST
MODEL RECOMMENDED CONTROL PRICE
KCIBF-56 DN3.0 KI-02.3 S £739
KCIBF-71 DN3.0 KI-02.3 S £793
KCIBF-80 DN3.0 KI-02.3 S £848
KCIBF-100 DN3.0 KI-02.3 S £921
KCIBF-112 DN3.0 KI-02.3 S £963
KCIBF-140 DN3.0 KI-02.3 S £1,108
(*) Price calculation based on the recommended controller.
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE INDOOR UNITS
157
The VRF AMAZON Duct units with DC INVERTER fans have a compact and versatile design that allows for adapting to every false ceiling installation. We truly believe this is a thorough product.
• Indoor units with DC INVERTER FAN.
• Broad range of capacities: from 1.5 kW to 14 kW, eleven models in total.
• Double air inlet possibility (rear or lower).
• Fresh air possibility to enter directly into the room through a pre-installation hole located at the unit’s body.
• Included frames for air inlet duct and air outlet duct as standard.
• Compatible with AIRZONE air-conditioning zoning systems.
• It contains a tilted evaporator; it provides a wider exchange area and a compact and reduced height, which facilitates the unit installation in rooms with a limited false ceiling.
• ON/OFF dry contact and 220 V alarm signal output.
• Receiver detaches up to 10 meters (optional cable).
• Possibility to change available static pressure by means of a dip-switch.
• Standard condensation pump.
DUCTSGENERAL CHARACTERISTICS
MODEL KPDF-15 DN3.0
KPDF-22 DN3.0
KPDF-28 DN3.0
KPDF-36 DN3.0
KPDF-45 DN3.0
Cooling capacity kW 1.5 2.2 2.8 3.6 4.5
Cooling capacity Kcal/h 1290 1892 2408 3096 3870
Heating capacity kW 1.7 2.6 3.2 4 5
Heating capacity Kcal/h 1462 2236 2752 3440 4300
Power input kW 0.039 0.039 0.039 0.045 0.058
Indoor airflow m3/h 509/420/370 521/450/380 521/450/380 592/541/426 748/640/550
Static pressure range (rated) Pa 0-30(10) 0-50(10) 0-50(10) 0-50(10) 0-50(10)
Sound pressure* dB (A) 31 31 31 33 33
Width/Height/Depth mm 740/210/500 740/210/500 740/210/500 740/210/500 960/210/500
Net weight Kg 17.5 17.5 17.5 17.5 22.5
Liquid pipe diameter mm (inch") Ø6.35 (1/4") Ø6.35 (1/4") Ø6.35 (1/4") Ø6.35 (1/4") Ø6.35 (1/4")
Gas pipe diameter mm (inch") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2")
Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
All AMAZON indoor units accept R-410 A refrigerant.*Sound pressure at low fan speed.
TECHNICAL SPECIFICATIONS
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
158
AM
AZ
ON
IND
US
TRIA
L V
RF
KCT-02.1 SR
MANUAL PRESSURE ADJUSTMENT AVAILABLE+
DC INVERTER FAN+
MODEL KPDF-56 DN3.0
KPDF-71 DN3.0
KPDF-80 DN3.0
KPDF-90 DN3.0
KPDF-112 DN3. 0
KPDF-140 DN3.0
K P D F - 9 0 DN2.4
Cooling capacity kW 5.6 7.1 8 9 11.2 14
Cooling capacity Kcal/h 4816 6106 6880 7740 9632 12040
Heating capacity kW 6.3 8 9 10 12.5 15.5
Heating capacity Kcal/h 5418 6880 7740 8600 10750 13330
Power input kW 0.089 0.068 0.098 0.108 0.178 0.204
Indoor airflow m3/h 821/640/566 1021/940/778 1290/1090/940 1290/1090/940 1780/1550/1352 1950/1600/1400
Static pressure range (rated) Pa 0-50(10) 0-50(10) 0-100(20) 0-100(20) 0-100(20) 25-150(40)
Sound pressure* dB (A) 33 34 37 37 37 38
Width/Height/Depth mm 960/210/500 1180/210/500 1180/270/775 1180/270/775 1180/270/775 1240/300/865
Net weight Kg 22.5 28 38 40 40 49
Liquid pipe diameter mm (inch") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8")
Gas pipe diameter mm (inch") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8")
Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
(*) RECOMMENDED
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE INDOOR UNITS
159
DUCTS
CONTROLLERS
KC-02.1 H
For further information, please see our Controllers range
KCT-02.1 SR
BMS AND SOFTWARE
CENTRALISEDINDIVIDUAL
KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB
K01-LON K01-BACNET KAYNET CONTROL K01-KNX K01-WIFIK02-MODBUS
KI-02.3 SKC-01 S
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you should add to the € price for the set the price
difference between the recommended controller and the selected controller.ELIGE TU CONTROL
CHOOSE YOUR CONTROL
COMPATIBLE WITH
MINI AMAZON2 PIPES
see pag. 182
AMAZON UNITARIO2 PIPES
see pag. 186
AMAZON III PRO3 PIPES
see pag. 196
AMAZON III W2 PIPES
see pag. 192
AMAZON IV PRO2 PIPES
see pag. 190
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
160
AM
AZ
ON
IND
US
TRIA
L V
RF
KCT-02.1 SR
DC INVERTER FAN+
(*) RECOMMENDED
MANUAL PRESSURE ADJUSTMENT AVAILABLE+
PRICE LISTMODEL RECOMMENDED CONTROL PRICE
KPDF-15 DN3.0 KCT-02.1 SR £461
KPDF-22 DN3.0 KCT-02.1 SR £465
KPDF-28 DN3.0 KCT-02.1 SR £474
KPDF-36 DN3.0 KCT-02.1 SR £492
KPDF-45 DN3.0 KCT-02.1 SR £593
KPDF-56 DN3.0 KCT-02.1 SR £610
KPDF-71 DN3.0 KCT-02.1 SR £661
KPDF-80 DN3.0 KCT-02.1 SR £695
KPDF-90 DN3.0 KCT-02.1 SR £760
KPDF-112 DN3.0 KCT-02.1 SR £848
KPDF-140 DN3.0 KCT-02.1 SR £865
(*) Price calculation based on the recommended controller.
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE INDOOR UNITS
161
DUCTSSTATIC PRESSURE GRAPHS
KPD-15 DN3.0
KPD-22 DN3.0 - KPD-28 DN3.0
KPD-36 DN3.0
Airflow (m3/h)Airflow (m3/h)Airflow (m3/h)
Airflow (m3/h)Airflow (m3/h)Airflow (m3/h)
Airflow (m3/h)Airflow (m3/h)
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
162
AM
AZ
ON
IND
US
TRIA
L V
RF
KPD-45 DN3.0
KPD-56 DN3.0
KPD-71 DN3.0
Airflow (m3/h)Airflow (m3/h)Airflow (m3/h)
Airflow (m3/h)Airflow (m3/h)Airflow (m3/h)
Airflow (m3/h)Airflow (m3/h)Airflow (m3/h)
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE INDOOR UNITS
163
DUCTSSTATIC PRESSURE GRAPHS
KPD-80 DN3.0
KPD-90 DN3.0
Airflow (m3/h)Airflow (m3/h)Airflow (m3/h)
Airflow (m3/h)Airflow (m3/h)Airflow (m3/h)
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
164
AM
AZ
ON
IND
US
TRIA
L V
RF
KPD-112 DN3.0
KPD-140 DN3.0
Airflow (m3/h)Airflow (m3/h)Airflow (m3/h)
Airflow (m3/h)Airflow (m3/h)Airflow (m3/h)
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE INDOOR UNITS
165
As their name suggest, these duct units supply higher static pressure, which allows for a more flexible design. They adapt to every installation space, even those with very high ceilings.
HIGH PRESSURE DUCTS
TECHNICAL SPECIFICATIONS
GENERAL CHARACTERISTICS
MODEL KPDHF-71 DN3.0
KPDHF-90 DN3.0
KPDHF-112 DN3.0
KPDHF-140 DN3.0
KPDHF-160 DN3.0
Cooling capacity kW 7.1 9 11.2 14 16
Cooling capacity Kcal/h 6106 7740 9632 12040 13760
Heating capacity kW 8 10 12.5 16 17
Heating capacity Kcal/h 6880 8600 10750 13760 14620
Power input kW 0.18 0.22 0.38 0.42 0.7
Indoor airflow m3/h 1325/1150/950 1650/1550/1450 2050/1850/1575 2800/2300/1800 3300/2600/2100
Static pressure range (rated) Pa 0-100 (75) 0-100 (75) 0-100 (75) 0-100 (75) 0-100 (75)
Sound pressure* dB (A) 42 45 45 48 50
Width/Height/Depth mm 952/420/690 952/420/690 952/420/690 1300/420/690 1300/420/690
Net weight Kg 41 47 47 68 78
Liquid pipe diameter mm (inch") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8")
Gas pipe diameter mm (inch") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8")
Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
All AMAZON indoor units accept R-410 A refrigerant.*Sound pressure at low fan speed.
• ON/OFF dry contact and 220 V alarm signal output.
• The expansion valve is integrated inside the 16 kW models; models over 20 kW have expansion valve fitted on the side of the unit.
• Compatible with AIRZONE air-conditioning zoning systems.
• Units with high airflows.
• Power range from 7.1 kW to 56 kW.
• Units with a DC INVERTER FAN (a power range from 7.1 kW to 28 kW).
• Condensation pump not included.
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
166
AM
AZ
ON
IND
US
TRIA
L V
RF
MODEL KPDHF-200 DN3.0
KPDHF-250 DN3.0
KPDHF-280 DN3.0
KPDHF-400 DN2.4
KPDHF-450 DN2.4
KPDHF-560 DN2.4
Cooling capacity kW 20 25 28 40 45 56
Cooling capacity Kcal/h 17200 21500 24080 34400 38700 48160
Heating capacity kW 22.5 26 31.5 45 50 63
Heating capacity Kcal/h 19350 22360 27090 38700 43000 54180
Power input kW 0.8 0.8 0.8 2.7 2.7 3.4
Indoor airflow m3/h 4800/3900/3500 4600/4000/3600 4600/4000/3600 7700/6400/5200 7700/6400/5200 10100/8400/7000
Static pressure range (rated) Pa 0-200 (120) 0-200 (120) 0-200 (120) 0-200 (125) 0-200 (125) 0-200 (125)
Sound pressure* dB (A) 50 50 50 56 56 57
Width/Height/Depth mm 1443/470/810 1443/470/810 1443/470/810 1970/668/902.5 1970/668/902.5 1970/668/902.5
Net weight Kg 108 108 108 232 232 235
Liquid pipe diameter mm (inch") ø9.52 (3/8") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2") Ø15.9 (5/8")
Gas pipe diameter mm (inch") Ø22.3 (7/8") Ø22.3 (7/8") Ø22.3 (7/8") Ø28.6 (1 1/8") Ø28.6 (1 1/8") Ø28.6 (1 1/8")
Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x4 (2+T)x4 (2+T)x4
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
FILTER NOT INCLUDED
KCT-02.1 SR
(*) RECOMMENDED
compatible with
HIGH AIRFLOWS+FROM 7.1 KW TO 28 KW DC INVERTER FANS+
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE INDOOR UNITS
167
HIGH PRESSURE DUCTS
CONTROLLERS
KC-02.1 H
For further information, please see our Controllers range
KCT-02.1 SR
BMS AND SOFTWARE
CENTRALISEDINDIVIDUAL
KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB
K01-LON K01-BACNET KAYNET CONTROL K01-KNX K01-WIFIK02-MODBUS
KI-02.3 SKC-01 S
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you should add to the € price for the set the price
difference between the recommended controller and the selected controller.ELIGE TU CONTROL
CHOOSE YOUR CONTROL
COMPATIBLE WITH
MINI AMAZON2 PIPES
see pag. 182
AMAZON UNITARIO2 PIPES
see pag. 186
AMAZON III PRO3 PIPES
see pag. 196
AMAZON III W2 PIPES
see pag. 192
AMAZON IV PRO2 PIPES
see pag. 190
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
168
AM
AZ
ON
IND
US
TRIA
L V
RF
compatible with
KCT-02.1 SR(*) RECOMMENDED
HIGH AIRFLOWS+FROM 7.1 KW TO 28 KW DC INVERTER FANS+
(*) Price calculation based on the recommended controller.
PRICE LISTMODEL RECOMMENDED CONTROL PRICE
KPDHF-71 DN3.0 KCT-02.1 SR £770
KPDHF-90 DN3.0 KCT-02.1 SR £861
KPDHF-112 DN3.0 KCT-02.1 SR £915
KPDHF-140 DN3.0 KCT-02.1 SR £963
KPDHF-160 DN3.0 KCT-02.1 SR £1,010
KPDHF-200 DN3.0 KCT-02.1 SR £1,377
KPDHF-250 DN3.0 KCT-02.1 SR £1,408
KPDHF-280 DN3.0 KCT-02.1 SR £1,438
KPDHF-400 DN2.4 KCT-02.1 SR £2,456
KPDHF-450 DN2.4 KCT-02.1 SR £2,571
KPDHF-560 DN2.4 KCT-02.1 SR £2,690
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE INDOOR UNITS
169
This is an interface that allows you to connect a UTA (air terminal unit) with a direct-expansion heat exchanger to the VRF system. This unit shall be treated like an additional indoor unit within the VRF system.
• It allows for installing direct expansion heat exchangers of up to 56kW.
• It consists of an electrical control box, electronic expansion valve, cables and control sensors.
• It includes an XYE port to connect to a centralised indoor unit control.
• ON/OFF dry contact and 220 V alarm signal output.
• Compatible only with 2 pipes outdoor units.
• More than one unit can be connected at the same time to increase the connectable capacity.
KAHU
GENERAL CHARACTERISTICS
TECHNICAL SPECIFICATIONS
MODEL KAHU-200.2 KAHU-360.2 KAHU-560.2
Cooling capacity* kW From 9 to 20 From 21 to 36 From 37 to 56
Width/Height/Depth mm 350/375/150 350/375/150 350/375/150
Net weight Kg 8.4 8.7 8.9
Liquid pipe diameter inlet mm (inch") ø9.52 (3/8") Ø12.7 (1/2") Ø15.9 (5/8")
Liquid pipe diameter outlet mm (inch") ø9.52 (3/8") Ø12.7 (1/2") Ø15.9 (5/8")
Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5
Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50
* Capacity can be adjusted by a dip switch located at the electric board.
NEW
COMPATIBLE WITH
AMAZON UNITARIO2 PIPES
see pag. 186
AMAZON III W2 PIPES
see pag. 192
AMAZON IV PRO2 PIPES
see pag. 190
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
170
AM
AZ
ON
IND
US
TRIA
L V
RF
KCT-02.1 SR
ELECTRIC EXPANSION VALVE4
1 KCT-02.1 SR BUILT-IN WIRED CONTROLELECTRICAL CONTROL BOX2
TEMPERATURE SENSORS AND CABLES3
INSTALLATION EXAMPLE
STANDARD
BMS AND SOFTWARE CENTRALISED
KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEBK01-LON K02-MODBUS K01-BACNET KAYNET CONTROL K01-KNX K01-WIFI
KAHU
MARKET CLIMATE CONTROL
INDOOR UNITS
OUTDOOR UNIT
PQE
WITH DIRECT EXPANSION BATTERY
Liquid cooling pipeline
Gas cooling pipeline
PRICE LIST
MODEL STANDARD CONTROLLER PRICE
KAHU-200.2 KCT-02.1 SR £308
KAHU-360.2 KCT-02.1 SR £369
KAHU-560.2 KCT-02.1 SR £492
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE INDOOR UNITS
171
KAYSUN UK introduces the DOMESTIC HOT WATER RECOVERY KIT. It is an indoor unit specially designed for the AMAZON III PRO 3 pipes systems with heat recovery able to produce domestic hot water.
• Compatible with AMAZON III PRO 3 pipes units only.
• Water outlet temperature between 25ºC and 45ºC.
DOMESTIC HOT WATER RECOVERY KIT
GENERAL CHARACTERISTICS
TECHNICAL SPECIFICATIONS
MODEL KWF-140 ACS
Heating capacity kW 14
Heating capacity Kcal/h 12040
Power consumption kW 0.01
Water outlet temperature range ºC 25-45
Outdoor temperatures limits working in cooling mode ºC -5ºC to 35ºC
Outdoor temperatures limits working in heating mode ºC -15ºC to 35ºC
Water inlet pipe diameter Inches DN25
Water outlet pipe diameter Inches DN25
Design airflow m³/h 2.4 (from 2 to 3)
Liquid pipe diameter mm (inch") ø9.52 (3/8")
Gas pipe diameter mm (inch") Ø15.9 (5/8")
Sound pressure dB (A) 26
Width/Height/Depth mm 500/900/373
Net weight Kg 55
Power cord (10 m max.) mm2 (2+T)x2.5
Shielded communication wires mm2 3x1.5
Power supply V / F / Hz 220-240/1/50
COMPATIBLE WITH
AMAZON III PRO3 PIPES
see pag. 196
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
172
AM
AZ
ON
IND
US
TRIA
L V
RF
AMAZON III PRO 3 PIPES OUTDOOR UNITDOMESTIC HOT WATER RECOVERY KIT
INDOOR UNIT
INSTALLATION EXAMPLE
KVBM2-DN3
DOMESTIC HOT WATER
KVBM2-DN3
DOMESTIC HOT WATER+
PRICE LIST
MODEL PRICE
KWF-140 ACS £862
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
174
POWER RANGE
2 PIPES
MINI AMAZON VRF
AMAZON UNITARIO
AMAZON IV PRO
SINGLE-PHASE
SIDE AIR DISCHARGE
TOP AIR DISCHARGE
KMF-80 DVN3 KMF-105 DVN3 KMF-120 DVN2
KMF-120 DTN2
KMF-140 DVN2
KMF-140 DTN2
KMF-160 DVN2
KMF-160 DTN2 KMF-180 DTN2
AMAZON III W
AMAZON III PRO
THREE-PHASE
POWER kW
OUTDOOR UNITS
FULL DC INVERTER
FULL DC INVERTER
8.0 10.5 12.0 14.0 16.0 18.0
3 PIPES POWER kW 8.0 10.5 12.0 14.0 16.0 18.0
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
175
AM
AZ
ON
IND
US
TRIA
L V
RF
COMBINABLE UP TO 4 MODULES
KMF-200 DN2 KMF-224 DN2
K2F-252 DN4 S
KMF-260 DN2
K2UF-280 DN3
K2F-280 DN4 S
K2UF-335 DN3
K2F-280 DN4 S
COMBINABLE UP TO 3 MODULES
K2F-252 DN3W K2F-280 DN3W K2F-335 DN3W
K2UF-400 DN3
K2F-400 DN4 S
KMF-400 DN3
K2UF-450 DN3
K2F-450 DN4 S
KMF-450 DN3
K2UF-560 DN3
K2F-560 DN4 S
K2UF-615 DN3 K2UF-670 DN3
K2F-615 DN4 SK2F-500 DN4 S
COMBINABLE UP TO 4 MODULES
K3F-252 DN3 S K3F-280 DN3 S K3F-335 DN3 S K3F-400 DN3 S K3F-450 DN3 S
20.0 22.4 25.2 26.0 28.0 33.5 40.0 45.0 50.0 56.0 61.5 67.0
20.0 22.4 25.2 26.0 28.0 33.5 40.0 45.0 50.0 56.0 61.5 67.0
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
176
OUTDOOR UNITS - 2 PIPES
AMAZON IV PRO
KAYSUN UK continues to focus on its AMAZON IV PRO range. All the compressors and fans of this range are DC INVERTER, a feature that turns this new model into a FULL DC INVERTER. Furthermore, unlike previous ranges, these units are fitted with 2 additional modules, thereby allowing for more combinations. Now we have 8 modules from 8HP to 22HP, which are available to combine up to 88 HP (4 modules maximum). We would like to highlight this range's novel and dynamic design, unique on the market, which compared to previous models, allows for installing the units in smaller spaces according to their capacity. As is always the case, depending on the type of combination, the units of this new range allow us to connect up to 64 indoor units. However, some of the most outstanding features of previous models have been kept for this new range, such as: Delta-shaped heat exchangers that enhance subcooling and allow for longer installation distances, auto-addressing function, up to 150% simultaneity, silent ventilation and 40Pa available pressure in fan motors.
AMAZON UNITARIO
AMAZON UNITARIO, the KAYSUN UK range of non-combinable units, has 7 units with 28kW to 67kW top air discharge and up to 40Pa available pressure, and 5 side air discharge units from 20kW to 45kW. This INVERTER technology single solution of KAYSUN UK allows for combining up to 39 indoor units and a 200 metres maximum installation distance between the outdoor unit and the furthest indoor unit. This unit also provides up to 150% simultaneity, highly efficient compressors, a silent ventilation system and a rotary electric box in 20, 22 and 24 HP modules. This is a very thorough and competitive product.
2 PIPESVRF OUTDOOR UNITS
FULL DC INVERTER+
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
177
AM
AZ
ON
IND
US
TRIA
L V
RF
MINI AMAZON VRF
The 2-pipe MINI AMAZON generation with DC Inverter compressor and fan motor keeps its 9 models. The design of fan´s blades and grille, as well as the DC Inverter technology used therein and in the “Twin Rotary“ compressor motor, provides the unit with outstanding energy efficiency and work range. KAYSUN UK seeks to provide versatility and total freedom, adding up to 9 indoor units to the combinations of the MINI AMAZON range and expanding the cooling distances up to 60 meters of actual overall length. Outdoor units automatically distribute the address to indoor units with no manual adjustment. In addition, the cooling pipeline of the 12, 14, 16 and 18 kW models can be installed in 4 different positions, thereby making installation easier. Moreover, the XYE port in the outdoor unit's board allows for the connection of the centralised control panel of indoor unit directly to the outdoor unit.
AMAZON III W
AMAZON III W range of 2 water condensed pipes with DC INVERTER compressors stands out from the whole range because of its modular design, which supports combinations up to 36 HP through the combination of 3 basic modules of 8-10-12 HP with which you can install up to a maximum of 59 indoor units. The structure of the new unit is much more compact and lightweight compared to the AMAZON air-condensed outdoor units. Thanks to its small size and the possibility of vertical installation (one outdoor on top of the other due to the lack of fans) allows it to be installed in very tight spaces.The lack of fans obviously reduces the sound pressure levels of outdoor units. Furthermore, due to the savings on consumption resulting from the lack of fans, energy efficiency notably increases if compared to the AMAZON air-condensed system, making it one of the strengths of the AMAZON III W.
The AMAZON range offers a wide variety of installation possibilities of indoor units with different ranges of cooling capacity, thereby allowing for the installation of 64 indoor units maximum, depending on the outdoor unit model or combinations thereof. This combination flexibility allows it to adapt to a wide variety of projects. One solution for every single need. KAYSUN's VRF system allows for installations with 50 % to 150% concurrence.
AMAZON equipment allows for designing and arranging an entire cooling and heating system with greater flexibility. The planning and design difficulty inherent to air-conditioning projects in complex or large buildings are made simple thanks to the long pipes distance and height provided by our range of products.
Wall Double flow console Art flux 360º cassette
OUTDOOR UNIT
Exposed floor unit Duct High pressure duct
INDOOR UNITS
64 UP TO 64 INDOOR UNITS
MULTIPLE COMBINATIONS
SYSTEMS WITH LONG DISTANCE COOLING PIPELINES
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
178
OUTDOOR UNITS - 2 PIPES
MINI AMAZON II SINGLE-PHASE
MODEL KMF-80 DVN3 KMF-105 DVN3 KMF-120 DVN2 KMF-140 DVN2 KMF-160 DVN2
Cooling capacity kW 8.0 10 12.3 14.0 15.5
Cooling capacity Kcal/h 6880 8600 10578 12040 13330
Cooling input kW 2.05 2.30 3.25 3.95 4.52
Heating capacity kW 8.4 10.5 13.2 15.4 17.00
Heating capacity Kcal/h 7224 9030 11352 13244 14620
Heating input kW 1.79 2.27 3.47 4.16 4.77
SEER 5.1 5.2 7.1 6.68 6.42
SCOP 3.8 3.8 4.11 3.96 3.83
Amount of connectable indoor units 4 5 6 6 7
Power supply V / F / Hz 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50
Inverter compressor 1 1 1 1 1
Fans 1 1 2 2 2
Liquid pipe diameter mm (Inch) Ø9.53 (3/8") Ø9.53 (3/8") Ø9.53 (3/8") Ø9.53 (3/8") Ø9.53 (3/8")
Gas pipe diameter mm (inches) Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø19.1 (3/4")
Refrigerant type R-410A R-410A R-410A R-410A R-410A
Refrigerant factory charge gr 2800 2950 3300 3900 3900
Airflow m3/h 3600 5100 6000 6000 6000
Width/Height/Depth mm 990/966/336 990/966/336 900/1327/320 900/1327/320 900/1327/320
Net weight Kg 62 72 95 95 100
Sound pressure dB (A) 56 57 54 54 54
Power cord (under 20 metres) mm2 (2+T)x2.5 (2+T)x4 (2+T)x4 (2+T)x6 (2+T)x6
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5
Cooling mode outdoor operation range
Cº -15 to 48 -15 to 48 -15 to 48 -15 to 48 -15 to 48
Heating mode outdoor operation range Cº -20 to 48 -20 to 48 -20 to 48 -20 to 48 -20 to 48
TECHNICAL SPECIFICATIONS
BRANCH PIPES
MODEL PRICE
KCMI 112 (KCMI100 + KCMI200) £46
BRANCH PIPES PRICE LIST
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
179
AM
AZ
ON
IND
US
TRIA
L V
RF
8 / 10.5
The MINI AMAZON II VRF system is ideal to meet the needs in small industrial environments. Its direct-expansion technology for 2 pipes aircooled covers a range of cooling capacities from 8 up to 26 kW in single-phase models.
• Depending on the model, single-phase units accept up to 7 indoor units.
• It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.
• Since it is fitted with side air discharge, it does not require much space for installation or maintenance.
• The entire range works only with DC Inverter compressors and fans, which provides it with remarkable energy efficiency and low consumption and sound levels.
• Compressor with highly-efficiency double eccentric Twin Rotary DC Inverter with environmentally friendly refrigerant R410A.
• It includes a auto-addressing feature for indoor units.
• The outdoor unit includes the XYE port to communicate with the centralised control panel of indoor units.
• The cooling pipeline of 12, 14 and 16kW models may be installed in 4 different positions, thereby facilitating their installation.
• Up to 70 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).
GENERAL CHARACTERISTICS
12 / 14 / 16
UP TO 7 INDOOR UNITS +
DC INVERTER COMPRESSOR AND FAN+ERP
PRICE LIST
MODEL PRICE
KMF-80 DVN3 £1,708
KMF-105 DVN3 £2,230
KMF-120 DVN2 £2,381
KMF-140 DVN2 £2,450
KMF-160 DVN2 £2,576
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
180
OUTDOOR UNITS - 2 PIPES
MINI AMAZON II THREE-PHASE
MODEL KMF-120 DTN2 KMF-140 DTN2 KMF-160 DTN2 KMF-180 DTN2
Cooling capacity kW 12.3 14.0 15.5 17.5
Cooling capacity Kcal/h 10578 12040 13330 15050
Cooling input kW 3.25 4.08 4.52 5.60
Heating capacity kW 13.2 15.4 17.0 19.0
Heating capacity Kcal/h 11352 13244 14620 16340
Heating input kW 3.47 4.12 4.77 5
SEER 7.1 6.68 6.42 6.21
SCOP 4.11 3.96 3.83 3.92
Amount of connectable indoor units 6 6 7 9
Power supply V / F / Hz 380-400 / 3 / 50 380-400 / 3 / 50 380-400 / 3 / 50 380-400 / 3 / 50
Inverter compressor 1 1 1 1
Fans 2 2 2 2
Liquid pipe diameter mm (Inch) Ø9.53 (3/8") Ø9.53 (3/8") Ø9.53 (3/8") Ø9.53 (3/8")
Gas pipe diameter mm (inches) Ø15.9 (5/8") Ø15.9 (5/8") Ø19.1 (3/4") Ø19.1 (3/4")
Refrigerant type R-410A R-410A R-410A R-410A
Refrigerant factory charge gr 3300 3900 3900 4500
Airflow m3/h 6000 6000 6000 6800
Width/Height/Depth mm 900/1327/320 900/1327/320 900/1327/320 900/1327/320
Net weight Kg 95 95 102 107
Sound pressure dB (A) 57 57 57 59
Power cord (under 20 metres) mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5
Cooling mode outdoor operation range Cº -15 to 48 -15 to 48 -15 to 48 -15 to 48
Heating mode outdoor operation range Cº -20 to 48 -20 to 48 -20 to 48 -20 to 48
TECHNICAL SPECIFICATIONS
BRANCH PIPES
MODEL PRICE
KCMI 112 (KCMI100 + KCMI200) £46
BRANCH PIPES PRICE LIST
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
181
AM
AZ
ON
IND
US
TRIA
L V
RF
GENERAL CHARACTERISTICS
The MINI AMAZON II VRF system is ideal to meet the needs in small industrial environments. Its direct-expansion technology for 2 pipes aircooled covers a range of cooling capacities from 12 up to 18 kW in three-phase models.
• Depending on the model, three-phase units accept up to 9 indoor units.
• It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.
• Since it is fitted with side air discharge, it does not require much space for installation or maintenance.
• The entire range works only with DC Inverter compressors and fans, which provides it with remarkable energy efficiency and low consumption and sound levels.
• Compressor with highly-efficiency double eccentric Twin Rotary DC Inverter with environmentally friendly refrigerant R410A.
• It includes an auto-addressing feature for indoor units.
• The outdoor unit includes the XYE port to communicate with the centralised control panel of indoor units.
• The cooling pipeline of 12, 14, 16 and 18 kW models may be installed in 4 different positions, thereby facilitating their installation.
• Up to 70 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).
UP TO 12 INDOOR UNITS +
DC INVERTER COMPRESSOR AND FAN+
12 / 14 / 16 / 18
PRICE LIST
MODEL PRICE
KMF-120 DTN2 £2,381
KMF-140 DTN2 £2,450
KMF-160 DTN2 £2,576
KMF-180 DTN2 £2,821
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
182
OUTDOOR UNITS - 2 PIPES
SIDE AIR DISCHARGEAMAZON UNITARIO
MODEL KMF-200 DN2 KMF-224 DN2 KMF-260 DN2 KMF-400 DN3 KMF-450 DN3
Cooling capacity kW 20.0 22.4 26.0 40.0 45.0
Cooling capacity Kcal/h 17200 19264 22360 34400 38700
Cooling input kW 6.10 6.80 7.60 11.90 13.60
Heating capacity kW 22.0 24.5 28.5 45.0 50.0
Heating capacity Kcal/h 18920 21070 24510 38700 43000
Heating input kW 6.10 5.90 6.80 11.10 12.70
SEER 6.19 6.21 6.42 6.26 6.2
SCOP 3.76 3.97 4.05 5.33 5.2
Amount of connectable indoor units 10 11 12 14 15
Power supply V / F / Hz 380-400 / 3 / 50 380-400 / 3 / 50 380-400 / 3 / 50 380-400 / 3 / 50 380-400 / 3 / 50
Inverter compressors 1 1 1 2 2
Fans 2 2 2 2 2
Liquid pipe diameter mm (Inch) Ø9.53 (3/8") Ø9.53 (3/8") Ø9.53 (3/8") Ø12.7 (1/2") Ø12.7 (1/2")
Gas pipe diameter mm (Inch) Ø19.1 (3/4") Ø19.1 (3/4") Ø22.2 (7/8") Ø22.2 (7/8") Ø25.4 (1")
Refrigerant type R-410A R-410A R-410A R-410A R-410A
Refrigerant factory charge gr 4800 6200 6200 9000 12000
Airflow m3/h 10999 10494 10494 16575 16575
Width/Height/Depth mm 1120/1558/400 1120/1558/400 1120/1558/400 1360/1650/540 1360/1650/540
Net weight Kg 137 146 147 240 275
Sound pressure dB (A) 59 59 60 62 62
Power cord (under 20 metres) mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x10 (4+T)x16
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5
Cooling mode outdoor operation range Cº -15 to 48 -15 to 48 -15 to 48 -5 to 48 -5 to 48
Heating mode outdoor operation range Cº -20 to 48 -20 to 48 -20 to 48 -15 to 24 -15 to 24
TECHNICAL SPECIFICATIONS
BRANCH PIPES
MODEL PRICE
KCMI 112 (KCMI100 + KCMI200) £46
KCMI 212 (KCMI100 + KCMI200) £71
KCMI 312 (KCMI100 + KCMI200) £86
KCMI 412 (KCMI100 + KCMI200) £108
KCMI 512 (KCMI100 + KCMI200) £474
BRANCH PIPES PRICE LIST
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
183
AM
AZ
ON
IND
US
TRIA
L V
RF
GENERAL CHARACTERISTICS
• Depending on the model, they accept up to 15 indoor units.
• It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.
• Since it is fitted with side air discharge, it does not require much space for installation or maintenance.
• The entire range works only with Twin Rotary DC Inverter compressors and DC Inverter fans, which provides it with remarkable energy efficiency and low consumption and sound levels.
• Night mode is included as an option in order to reduce the sound level of outdoor units.
• It includes an auto-addressing feature for indoor units.
• The outdoor unit includes the XYE port to communicate with the centralised control panel of indoor units.
• Up to 120 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).
INVERTER COMPRESSORS AND FANS+
UP TO 15 INDOOR UNITS+
20 / 22 / 26 / 40 / 45
The AMAZON SINGLE SIDE DISCHARGE range has non-combinable external VRF units of between 20 kW and 45 kW. The big advantage of these units is the possibility to install higher power equipments in confined spaces.
PRICE LIST
MODEL PRICE
KMF-200 DN2 £3,261
KMF-224 DN2 £3,669
KMF-260 DN2 £3,832
KMF-400 DN3 £5,736
KMF-450 DN3 £6,540
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
184
OUTDOOR UNITS - 2 PIPES
TOP AIR DISCHARGEAMAZON UNITARIO
TECHNICAL SPECIFICATIONS
MODEL K2UF-280 DN3
K2UF-335 DN3
K2UF-400 DN3
K2UF-450 DN3
K2UF-560 DN3
K2UF-615 DN3
K2UF-670 DN3
Rated HP 10 12 14 16 20 22 24
Cooling capacity kW 28 33.5 40 45 56 61.5 67
Cooling capacity Kcal/h 24080 28810 34400 38700 48160 52890 57620
Cooling input kW 7.19 9.05 12.30 14.01 17.00 18.80 20.80
Heating capacity kW 32 38 45 50 63 69 75
Heating capacity Kcal/h 27090 32250 38700 43000 54180 59340 64500
Heating input kW 7.60 8.99 11.20 12.80 16.00 17.90 19.80
SEER 6.83 6.58 6.18 6.05 6.22 6.03 5.92
SCOP 5.94 5.95 5.52 5.29 5.32 5.27 5.04
Amount ofconnectable indoor units 16 16 16 20 33 36 39
Power supply V / F / Hz 380 / 3 / 50 380 / 3 / 50 380 / 3 / 50 380 / 3 / 50 380 / 3 / 50 380 / 3 / 50 380 / 3 / 50
Inverter compressor 1 1 1 1 1 1 1
Fixed Scroll compressors 0 1 2 2 2 2 2
Fans 1 2 2 2 2 2 2
Liquid pipe diameter mm (Inch) Ø12.7 (1/2") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø19.1 (3/4") Ø19.1 (3/4") Ø19.1 (3/4")
Gas pipe diameter mm (Inch) Ø25.4 (1") Ø31.8 (1 1/4") Ø31.8 (1 1/4") Ø31.8 (1 1/4") Ø31.8 (1 1/4") Ø31.8 (1 1/4") Ø31.8 (1 1/4")
Refrigerant type R-410 A R-410 A R-410 A R-410 A R-410 A R-410 A R-410 A
Refrigerant factory charge gr 10000 12000 15000 15000 17000 18500 18500
Airflow m3/h 11,000 15,000 15,000 15,000 18,000 22,100 22,100
Static Pressure Pa 40 40 40 40 40 40 40
Width/Height/Depth mm 960/1615/765 1250/1615/765 1250/1615/765 1250/1615/765 1390/1615/765 1585/1615/765 1585/1615/765
Net weight Kg 205 275 325 325 360 385 390
Sound pressure dB (A) 58 58 60 60 62 63 63
Power cord(under 20 metres) mm2 (4+T)*4 (4+T)*6 (4+T)*10 (4+T)*16 (4+T)*16 (4+T)*25 (4+T)*25
Communication wiring mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5
Cooling mode outdoor operation range Cº -5 to 48 -5 to 48 -5 to 48 -5 to 48 -5 to 48 -5 to 48 -5 to 48
Heating mode outdoor operation range Cº -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 27 -20 to 27 -20 to 27
BRANCH PIPES
MODEL PRICE £
KCMI 112 (KCMI100 + KCMI200) £46
KCMI 212 (KCMI100 + KCMI200) £71
KCMI 312 (KCMI100 + KCMI200) £86
KCMI 412 (KCMI100 + KCMI200) £108
KCMI 512 (KCMI100 + KCMI200) £474
BRANCH PIPES PRICE LIST
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
185
AM
AZ
ON
IND
US
TRIA
L V
RF
GENERAL CHARACTERISTICS
Direct-expansion system for 2 pipes aircooled pipes designed for 28 kW to 67 kW cooling capacity units. It is ideal for air-conditioning large spaces that require the creation of atmospheres with different temperatures.
• Individual (non-combinable) outdoor units with capacity ranging from 10 to 24 HP (7 models). This system is able to combine between 16 and 39 indoor units.
• It admits a 50% to 150% simultaneity index of the outdoor unit's power.
• Fitted with a top air discharge system, this range is able to make air circulates through the condensation system thanks to the 40 Pa available pressure supplied by its DC Inverter fan.
• Night mode is included as an option in order to reduce the sound level of outdoor units.
• Highly-efficiency scroll and fixed DC Inverter compressors with environmentally friendly R410A refrigerant.
• Night mode is included as an option in order to reduce the sound level of outdoor units.
• Up to 175 metres of actual length for the pipes connecting the outdoor unit with the farthest indoor unit.
NON-COMBINABLE SYSTEMS +
UP TO 39 INDOOR UNITS+
PRICE LIST
MODEL PRICE
K2UF-280 DN3 £4,611
K2UF-335 DN3 £5,711
K2UF-400 DN3 £6,490
K2UF-450 DN3 £7,005
K2UF-560 DN3 £8,714
K2UF-615 DN3 £9,481
K2UF-670 DN3 £10,046
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES
33
AMAZON IV PRO TECHNICAL SPECIFICATIONS
MODEL K2F-252 DN4S
K2F-280 DN4S
K2F-335 DN4S
K2F-400 DN4S
K2F-450 DN4S
K2F-500 DN4S
K2F-560 DN4S
K2F-615 DN4S
Capacity HP 8 10 12 14 16 18 20 22
Cooling capacity kW 25.2 28 33.5 40 45 50 56 61.5
Cooling capacity Kcal/h 21672 24080 28810 34400 38700 43000 48160 52890
Cooling input kW 5.79 7.02 8.71 10.81 12.83 14.47 16.67 18.77
Heating capacity kW 27 31.5 37.5 45 50 56 63 69
Heating capacity Kcal/h 23220 27090 32250 38700 43000 48160 54180 59340
Heating input kW 5.8 7.2 8.8 11.0 12.47 14.15 15.98 17.86
SEER 8.25 7.9 7.54 7.54 7.2 7.36 7.28 7.04
SCOP 6.52 6.35 6.13 6.03 5.82 5.67 5.5 5.25
Amount of connectable indoor units
13 16 19 23 26 29 33 36
Power supply V / F / Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50
Inverter compressor 1 1 1 2 2 2 2 2
Fans 1 1 1 2 2 2 2 2
Oil balance pipe diameter mm (Inch) Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4")
Liquid pipe diameter mm (Inch) Ø9.53 (3/8") Ø9.53 (3/8") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8")
Gas pipe diameter mm (Inch) Ø22.2 (7/8") Ø22.2 (7/8") Ø25.4 (1") Ø25.4 (1") Ø28.6 (1 1/8") Ø28.6 (1 1/8") Ø28.6 (1 1/8") Ø28.6 (1 1/8")
Refrigerant type R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A
Refrigerant factory charge gr 9000 9000 11000 13000 13000 13000 16000 16000
Airflow m3/h 12000 12000 12000 14000 14000 16000 16000 16000
Static Pressure Pa 40 40 40 40 40 40 40 40
Width/Height/Depth
mm 990/1635/790 990/1635/790 990/1635/790 1340/1635/790 1340/1635/790 1340/1635/790 1340/1635/790 1340/1635/790
Net weight Kg 219 219 237 297 297 305 340 340
Sound pressure dB (A) 58 59 60 62 62 63 63 63
Power cord(under 20 metres) mm2 (4+T)x2.5 (4+T)x4 (4+T)x6 (4+T)x10 (4+T)x16 (4+T)x16 (4+T)x16 (4+T)x16
Communication wiring
mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5
Cooling mode outdoor operation range
Cº From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48
Heating mode outdoor operation range
Cº From -20 to 24
From -20 to 24
From -20 to 24
From -20 to 24
From -20 to 24
From -20 to 24
From -20 to 24
From -20 to 24
BRANCH PIPES PRICE LISTBRANCH PIPES OUTDOOR MODULES BRANCH PIPES
MODEL PRICE
KCME 12 £123
KCME 13 £197
KCME 14 £351
MODEL PRICE
KCMI 112 (KCMI100 + KCMI200) £46
KCMI 212 (KCMI100 + KCMI200) £71
KCMI 312 (KCMI100 + KCMI200) £86
KCMI 412 (KCMI100 + KCMI200) £108
KCMI 512 (KCMI100 + KCMI200) £474
Design and Install for you
187
AM
AZ
ON
IND
US
TRIA
L V
RF
Direct-expansion system for 2 pipes aircooled designed for 25.2 kW to 246 kW cooling power units. Ideal for meeting the needs in medium and large industrial environments.
• This range is equipped with high capacity Scroll DC Inverter compressors and environmentally friendly R410A refrigerant. These features make these units even more efficient than previous models.
• The new design of the fan's blades and protection grille reduces sound levels and increase airflow. Modular design with the option of combining the 8 individual modules (8-10-12-14-16-18-20 and 22 HP) up to 88 HP (4 modules maximum).
• The 12, 20 and 22 HP models are smaller if compared to previous versions because we use an extra 21% of heat exchanger's surface.
• Standard automatic redundancy between modules. It balances and extends the working life of the compressors of each module, whether of the Master unit or any of the Slaves.
• They allow for combinations containing up to 64 indoor units.
• It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.
• Fitted with a top air discharge system, this range is able to make air circulates through the condensation system thanks to the 40 Pa available pressure supplied by its DC Inverter fan.
• Delta-shaped heat exchanger; it enhances subcooling values up to 12ºC and improves the exchanger's efficiency.
• Up to 200 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).
GENERAL CHARACTERISTICS
8 / 10 / 12 14 / 16 / 18 / 20 / 22
UP TO 64 INDOOR UNITS +
FULL DC INVERTER+
PRICE LIST
MODEL PRICE
K2F-252 DN4S £5,654
K2F-280 DN4S £5,969
K2F-335 DN4S £6,785
K2F-400 DN4S £7,854
K2F-450 DN4S £8,168
K2F-500 DN4S £9,173
K2F-560 DN4S £10,178
K2F-615 DN4S £11,184
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
188
OUTDOOR UNITS - 2 PIPES
AMAZON III W
MODEL K2F-252 DN3W K2F-280 DN3W K2F-335 DN3W
Capacity HP 8 10 12
Cooling capacity kW 25.2 28 33.5
Cooling capacity Kcal/h 21672 24080 28810
Cooling input kW 4.8 6.1 8
Heating capacity kW 27 31.5 37.5
Heating capacity Kcal/h 23220 27090 32250
Heating input kW 4.5 5.8 7.8
Amount of connectable indoor units 13 16 19
Power supply V / F / Hz 380-415/3/50 380-415/3/50 380-415/3/50
Inverter compressor 1 1 1
Heat exchanger type Shell and tube Shell and tube Shell and tube
Water flow rate m3/h 5.4 6.0 7.2
Load loss kPa 35 40 48
Water pipe max. pressure Mpa 1.98 1.98 1.98
Water inlet pipe diameter DN32 DN32 DN32
Water outlet pipe diameter DN32 DN32 DN32
Oil balance pipe diameter mm (Inch) Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4")
Liquid pipe diameter mm (Inch) Ø12.7 (1/2") Ø12.7 (1/2") Ø15.9 (5/8")
Gas pipe diameter mm (Inch) Ø25.4 (1") Ø25.4 (1") Ø31.8 (1 1/4")
Refrigerant type R-410A R-410A R-410A
Refrigerant factory charge gr 2000 2000 2000
Width/Height/Depth mm 780/1000/550 780/1000/550 780/1000/550
Net weight Kg 146 146 146
Sound pressure dB (A) 51.0 52.0 52.0
Power cord (under 20 metres) mm2 (4+T)x2.5 (4+T)x4 (4+T)x6
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5
Water inlet temperature range Cº From 7 to 45 From 7 to 45 From 7 to 45
TECHNICAL SPECIFICATIONS
BRACH PIPES PRICE LIST
BRANCH PIPES OUTDOOR MODULES BRANCH PIPES
MODEL PRICE
KCMI 112 (KCMI100 + KCMI200) £46
KCMI 212 (KCMI100 + KCMI200) £71
KCMI 312 (KCMI100 + KCMI200) £86
KCMI 412 (KCMI100 + KCMI200) £108
KCMI 512 (KCMI100 + KCMI200) £474
MODEL PRICE
KCME 12 £123
KCME 13 £197
KCME 14 £351
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
189
AM
AZ
ON
IND
US
TRIA
L V
RF
Direct-expansion system for 2 pipes watercooled designed for 25.2 kW to 100.5 kW cooling capacity units. Ideal for meeting the needs in medium and large industrial environments.
• This range is equipped with high capacity Scroll DC Inverter compressors and environmentally friendly R410A refrigerant. These features make these units a very efficient product.
• Modular design with the option of combining the 3 individual modules (8-10-12 HP) up to 36 HP (3 modules maximum).
• Shell and tube heat exchanger and highly-efficient cross airflow.
• Standard automatic redundancy between modules. It balances and extends the working life of the compressors of each module, whether of the Master unit or any of the Slaves.
• They allow for combinations containing up to 59 indoor units.
• It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.
• Because of the lack of fans, this system is more efficient that aircooled systems and provides low consumption and sound levels.
• Compared to previous aircooled outdoor units, this outdoor unit is more compact and lightweight and provides a significant reduction in weight, area and volume.
• Up to 150 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).
WATERCOOLED
GENERAL CHARACTERISTICS
UP TO 59 INDOOR UNITS +
PRICE LIST
MODEL PRICE
K2F-252 DN3W £5,497
K2F-280 DN3W £6,126
K2F-335 DN3W £7,162
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
190
OUTDOOR UNITS - 3 PIPES
VRF OUTDOOR UNITS
• New ventilation system One fan with 3 blades and a second fan with 4 blades
• AMAZON III PRO Full DC Inverter
• Compact and lightweight• Easy transport and installation. • Rotating electrical box
• DOUBLE SUBCOOLING: Condenser heat exchanger in delta form
• Subcooling takes place in exchanger.
FULL DC INVERTER
• 5 available modules from 25,2 kW to 45 kW• Up to 4 combinable modules (180 kW)• Up to 64 combinable indoor units • Optimized fan design• Better energy efficiency • Working range between -5º C and 48ºC in cool
mode and between -20ºC and 24ºC in heat mode
LONG DISTANCE COOLING PIPES1000 m
AMAZON III PRO
CONTINUOUS HEATING during defrosting
3 PIPES
CONTINUOUS HEATING DURING DEFROSTING
Thanks to double condenser, defrost is made in the first heat exchanger. Once it is finished, the same operation is realized in the second one. This way, all indoor units are kept in heating mode during the entire process. At the same time, the unit can work with a single condenser to compensate for the highest load of the system both in cold and heat, which represents substantial energy savings and remarkable energy efficiency in the cooling circuit.
DOUBLE SUBCOOLINGAMAZON III PRO 3 pipes has a dual system of liquid subcooling that increases the system's energy efficiency. The delta-shaped heat exchanger reduces its load loss by increasing liquid proportion and therefore, arranging longer pipeline lengths. Thanks to this subcooling technology, liquid temperatures at the condenser outlet may reach up to 37.1ºC.
The second stage of the subcooling process is carried out in each series inverter box since, thanks to a small liquid by-pass pipe, subcooling temperature may reach 22.1ºC.OPTIMISED FAN DESIGN
New ventilation system: one fan fitted with 3 blades and a second fan fitted with 4 blades. This reduces the effect of acoustic resonance that directly affects the noise level of the outdoor unit.
MAINTENANCE
Thanks to the rotary electrical box, the cooling circuit can be accessed more easily for maintenance and installation. At the same time, the electrical box is fitted with an inspection window at the electronic board to check any malfunction without disassembling it.
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
191
AM
AZ
ON
IND
US
TRIA
L V
RF
CHANGEOVER BOXES MULTIGROUP
Available in versions of 2, 4 and 6 outputs, the y support a maximum of 45 kW of capacity and up to 24 indoor units depending on the model (see table in the AMAZON III PRO changeover boxes section). Each output can work in a different mode.
This indoor unit, only for the AMAZON III PRO 3 pipes range, is capable of producing domestic hot water. Temperature adjustment ranges from 20ºC to 45ºC and is based on the water outlet temperature.
SIMULTANEITY BETWEEN HEATING AND COOLING
Thanks to the changeover boxes, the system is capable of providing heating and cooling simultaneously, generating heat recovery in the system and therefore overall energy savings.
DOMESTIC HOT WATER
CHANGEROVER BOXES
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
192
OUTDOOR UNITS - 3 PIPES
AMAZON III PRO
TECHNICAL SPECIFICATIONS
MODEL K3F-252 DN3S K3F-280 DN3S K3F-335 DN3S K3F-400 DN3S K3F-450 DN3S
Capacity HP 8 10 12 14 16
Cooling capacity kW 25.2 28 33.5 40 45
Cooling capacity Kcal/h 21,672 24,080 28,810 34,400 38,700
Cooling input kW 5.73 6.67 8.07 11.3 13.24
Heating capacity kW 27 32 38 45 50
Heating capacity Kcal/h 23220 27090 32250 38700 43000
Heating input kW 6.00 7.33 8.72 11.19 12.79
SEER 7.53 7.43 7.4 6.68 6.38
SCOP 6.23 6.05 6.02 5.67 5.45
Amount of connectable indoor units 13 16 20 23 26
Power supply V / F / Hz 380-415 / 3 / 50 380-415 / 3 / 50 380-415 / 3 / 50 380-415 / 3 / 50 380-415 / 3 / 50
Inverter compressor 1 1 1 2 2
Fans 2 2 2 2 2
Oil balance pipe diameter mm (Inch) Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4")
Liquid pipe diameter mm (Inch) Ø9.53 (3/8") Ø12.7 (1/2") Ø12.7 (1/2") Ø15.9 (5/8") Ø15.9 (5/8")
Gas high-pressure pipe diameter mm (Inch) Ø19.1 (3/4") Ø19.1 (3/4") Ø19.1 (3/4") Ø22.2 (7/8") Ø22.2 (7/8")
Gas low-pressure pipe diameter mm (Inch) Ø22.2 (7/8") Ø22.2 (7/8") Ø25.4 (1") Ø28.6 (1 1/8") Ø28.6 (1 1/8")
Gas balance high-pressure pipe diameter mm (Inch) Ø19.1 (3/4") Ø19.1 (3/4") Ø19.1 (3/4") Ø19.1 (3/4") Ø19.1 (3/4")
Refrigerant type R-410 A R-410 A R-410 A R-410 A R-410 A
Refrigerant factory charge gr 10000 10000 10000 13000 13000
Airflow m3/h 12000 12000 13000 15000 15000
Static Pressure Pa 40 40 40 40 40
Width/Height/Depth mm 1250/1615/765 1250/1615/765 1250/1615/765 1250/1615/765 1250/1615/765
Net weight Kg 255 255 255 303 303
Sound pressure dB (A) 57 57 58 60 60
Power cord (under 20 metres) mm2 (4+T)x2.5 (4+T)x4 (4+T)x6 (4+T)x10 (4+T)x16
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5
Cooling mode outdoor operation range Cº -5 to 48 -5 to 48 -5 to 48 -5 to 48 -5 to 48
Heating mode outdoor operation range Cº -20 to 24 -20 to 24 -20 to 24 -20 to 24 -20 to 24
BRANCH PIPES PRICE LIST
BRANCH PIPES - 3 PIPES BRANCH PIPES - 2 PIPES
OUTDOOR MODULES BRANCH PIPES
MODEL PRICE
KCMI 113 (KCMI100+KCMI200+KCMI200) £77
KCMI 213 (KCMI100+KCMI200+KCMI300) £102
KCMI 313 (KCMI200+KCMI300+KCMI300) £142
KCMI 413 (KCMI200+KCMI300+KCMI400) £163
KCMI 513 (KCMI300+KCMI400+KCMI500) £551
MODEL PRICE
KCMI 112 (KCMI100 + KCMI200) £46
MODEL PRICE
KCMER 32 £123
KCMER 33 £215
KCMER 34 £412
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
193
AM
AZ
ON
IND
US
TRIA
L V
RF
Direct-expansion system for 3 pipes aircooled designed for 25.2 kW to 180 kW cooling capacity units. Ideal for meeting the needs in medium and large industrial environments.
• High capacity Scroll DC Inverter compressors and ecological R410A refrigerant.
• Modular design with the option of combining the 5 individual modules (8-10-12-14 and 16 HP) up to 64 HP (4 modules maximum).
• Standard automatic redundancy between modules. It balances and extends the working life of the compressors of each module, whether of the Master unit or any of the Slaves.
• They allow for combinations containing up to 64 indoor units.
• It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.
• Fitted with a top air discharge system, this range is able to make air circulates through the condensation system thanks to the 40 Pa available pressure supplied by its DC Inverter fan.
• Cooling system with double liquid subcooling; the first system performs the subcooling process thanks to the delta-shaped heat exchanger and the second system carries out the subcooling process in each changeover box, thereby reaching up to 22.1 ºC and very high levels of energy efficiency.
• Up to 200 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).
GENERAL CHARACTERISTICS
FULL DC INVERTER
A NEW DESIGN WITH NOISE LEVELS REDUCTION THAT WHICH INCREASES AIRFLOW
INDOOR UNITS 64
DC
dB
INVERTER
PRICE LIST
MODEL PRICE
K3F-252 DN3S £6,281K3F-280 DN3S £6,651K3F-335 DN3S £7,643K3F-400 DN3S £8,624K3F-450 DN3S £9,045
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
194
OUTDOOR UNITS - 3 PIPES
CHANGEOVER BOXES
Thanks to the changeover boxes, the system is capable of providing heating and cooling simultaneously, generating heat recovery in the system and therefore overall energy savings.
Available in versions of 2.4 and 6 outputs, they support a maximum of 45 kW of capacity and up to 24 indoor units depending on the model (for further information, please see attached table). Each output can work in a different mode.
CHANGEOVER BOXES MULTIGROUPPER OUTPUT PER BOX
MODELNUMBER OF
OUTPUTSMax UI Capacity
(KW)Max UI Capacity
(KW)Max UI Capacity
(KW)Max UI Capacity
(KW)
KVBM2 DN3 2 16 4 28 8
KVBM4 DN3 4 16 4 45 16
KVBM6 DN3 6 16 4 45 24
COOLING
HEATING
GENERAL CHARACTERISTICS
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
195
AM
AZ
ON
IND
US
TRIA
L V
RF
CHANGEOVER BOX
TECHNICAL SPECIFICATIONS
MODEL KVBM2 DN3 KVBM4 DN3 KVBM6 DN3
Cooling capacity kW Up to 28 Up to 45 Up to 45
Cooling capacity per output kW Up to 16 Up to 16 Up to 16
Max. amount of connectable indoor units 8 16 24
Maximum amount of indoor units per output 4 4 4
Width/Height/Depth mm 630/225/600 960/225/600 960/225/600
Net weight Kg 19.5 31 35
Liquid inlet pipe diameter mm (Inch) Ø12.7 (1/2") Ø15.9 (5/8") Ø15.9 (5/8")
Gas inlet high-pressure pipe diameter mm (Inch) Ø19.1 (3/4") Ø22.2 (7/8") Ø22.2 (7/8")
Gas inlet low-pressure pipe diameter mm (Inch) Ø25.4 (1") Ø31.8 (1 1/4") Ø31.8 (1 1/4")
Liquid pipe diameter per outlet mm (Inch) Ø9.53 (3/8") Ø9.53 (3/8") Ø9.53 (3/8")
Gas pipe diameter per outlet mm (Inch) Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8")
Shielded communication wires mm2 3x1.5 3x1.5 3x1.5
Power cord (under 20 metres) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5
Power supply voltage V / F / Hz 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50
PRICE LIST
MODEL PRICE
KVBM2 DN3 £996
KVBM4 DN3 £1,514
KVBM6 DN3 £2,117
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
196
SIZING OF PIPES
MINI AMAZON II / AMAZON UNITARIO SIDE AIR DISCHARGE 2 PIPES
HOW TO CHOOSE THE DISTRIBUTOR AND THE REFRIGERANT PIPELINE
CAPACITY OF UNITS HANGING FROM THE DISTRIBUTOR AND THE PIPE (X100 W)
PIPES DIMENSIONDRIFTERS
GAS LIQUID
<166 Ø15.9 (5/8") Ø9.5 (3/8") KCMI-100B-200B (KCMI 112)
166≤A<230 Ø19.1 (3/4") Ø9.5 (3/8") KCMI-100B-200B (KCMI 112)
230≤A<330 Ø22.2 (7/8") Ø9.5 (3/8") KCMI-100B-300B (KCMI 212)
330≤A Ø28.6 (1 1/8") Ø12.7 (1/2") KCMI-100B-300B (KCMI 212)
INDOOR UNITS TOTAL CAPACITYOF PIPE (X100 W)
LENGTH ≤10M LENGTH > 10M
LIQUID GAS LIQUID GAS
A≤45 Ø6.4(1/4") Ø12.7 (1/2") Ø9.5 (3/8") Ø15.9 (5/8")
56≤A≤160 Ø9.5 (3/8") Ø15.9 (5/8") Ø12.7 (1/2") Ø19.1 (3/4")
A≤200 Ø9.5 (3/8") Ø22.2 (7/8") Ø12.7 (1/2") Ø25.4 (1")
A≤ 250 Ø12.7 (1/2") Ø22.2 (7/8") Ø12.7 (1/2”) Ø22.2 (7/8”)
SIZING OF PIPES
1 Selection of the right pipe for indoor unit (pipes a-f)
2 Selection of distributors (A-E) and pipes (L2-L5)
DISTANCES AND HEIGHT DIFFERENCES
A - Capacity of indoor unit/units
A - Capacity of indoor unit/units
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
197
AM
AZ
ON
IND
US
TRIA
L V
RF
EQUIVALENT LENGTH OF LIQUID PIPE <45 EQUIVALENT LENGTH OF LIQUID PIPE ≥45
CAPACITY OF UNITS HANGING FROM THE
DISTRIBUTOR AND THE PIPE (X100 W)
GAS LIQUID DRIFTERS GAS LIQUID DRIFTERS
A<166 Ø15.9 (5/8") Ø9.5 (3/8")KCMI-100B-200B
(KCMI 112)Ø19.1 (3/4") Ø12.7 (1/2")
KCMI-100B-200B (KCMI 112)
166 ≤A <230 Ø19.1 (3/4") Ø9.5 (3/8")KCMI-100B-200B
(KCMI 112)Ø22.2 (7/8") Ø12.7 (1/2")
KCMI-100B-200B (KCMI 112)
230 ≤A <330 Ø22.2 (7/8") Ø9.5 (3/8")KCMI-100B-300B
(KCMI 212)Ø25.4 (1") Ø12.7 (1/2")
KCMI-100B-300B (KCMI 212)
330 ≤A <430 Ø22.2 (7/8") Ø12.7 (1/2")KCMI-100B-300B
(KCMI 212)Ø25.4 (1") Ø12.7 (1/2")
KCMI-100B-300B (KCMI 212)
430 ≤A <450 Ø25.4 (1") Ø12.7 (1/2”)KCMI-100B-300B
(KCMI 212)Ø28.6 (1 1/8") Ø12.7 (1/2")
KCMI-200B-300B (KCMI 312)
Important: Main pipe L1 can be selected from Table 2 or from Table 3, always trying to choose the most unfavourable option.
L1 A
B
L2
a
b
L4
N2
N1
C L5
D c
d
e
f E
L3
N6
N5
N3
N4
3 Selection of main pipe (L1):
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
198
SIZING OF PIPES
TOTAL CAPACITY OF UNITS HANGING FROM THE DISTRIBUTOR (X100 W)
PIPES DIMENSIONDRIFTERS
GAS LIQUID
A<166 Ø15.9 (5/8”) Ø9.5 (3/8") KCMI 100B-200B (KCMI 112)
166≤A<230 Ø19.1 (3/4”) Ø9.5 (3/8") KCMI 100B-200B (KCMI 112)
230≤A<330 Ø22.2 (7/8") Ø9.5 (3/8”) KCMI 100B-300B (KCMI 212)
330≤A<460 Ø28,6 (1 1/8") Ø12.7 (1/2") KCMI 100B-300B (KCMI 212)
460≤A<660 Ø28,6 (1 1/8") Ø15.9 (5/8") KCMI 200B-300B (KCMI 312)
660≤A<920 Ø34.9 (1 3/8") Ø19.1 (3/4") KCMI 200B-400B (KCMI 412)
920≤A<1350 Ø41.3 (1 5/8") Ø19.1 (3/4") KCMI 200B-400B (KCMI 412)
1350≤A<1800 Ø41.3 (1 5/8") Ø22.2 (7/8") KCMI 300B-500B (KCMI 512)
1800≤A Ø53.9 (2 1/8") Ø25.4 (1") KCMI 300B-500B (KCMI 512)
SET REFERENCE LIQUID GAS
KCMI 100B-200B (KCMI 112) E-100FRGB E-200FRGB
KCMI 100B-300B (KCMI 212) E-100FRGB E-300FRGB
KCMI 200B-300B (KCMI 312) E-200FRGB E-300FRGB
KCMI 200B-400B (KCMI 412) E-200FRGB E-400FRGB
KCMI 300B-500B (KCMI 512) E-300FRGB E-500FRGB
TOTAL CAPACITY OF INDOOR UNITS OF THE PIPE
(X100 W)
LENGTH ≤10M LENGTH > 10M
LIQUID GAS LIQUID GAS
≤45 Ø6.4 (1/4”) Ø12.7 (1/2”) Ø9.5 (3/8”) Ø15.9 (5/8”)
56≤A≤160 Ø9.5 (3/8”) Ø15.9 (5/8”) Ø12.7 (1/2”) Ø19.1 (3/4")
200 Ø9.5 (3/8”) Ø22.2 (7/8") Ø12.7 (1/2”) Ø25.4 (1")
250 Ø12.7 (1/2”) Ø22.2 (7/8") Ø12.7 (1/2”) Ø22.2 (7/8")
280 Ø12.7 (1/2”) Ø22.2 (7/8") Ø12.7 (1/2”) Ø22.2 (7/8")
400 Ø12.7 (1/2”) Ø28.6 (1 1/8”) Ø12.7 (1/2”) Ø22.2 (7/8")
450 Ø12.7 (1/2”) Ø28.6 (1 1/8”) Ø12.7 (1/2”) Ø22.2 (7/8")
560 Ø15.9 (5/8”) Ø28.6 (1 1/8”) Ø12.7 (1/2”) Ø22.2 (7/8")
AMAZON UNITARIO TOP AIR DISCHARGE / AMAZON III W / AMAZON IV PRO 2 PIPES
1 Selection of indoor unit pipe (pipes a-i)
Note: If the total capacity of indoor units exceeds the capacity of outdoor units, we will respect duct A from Table 3.
HOW TO CHOOSE THE DISTRIBUTOR AND THE REFRIGERANT PIPELINE
2 Selection of drifters (A - H) and pipes (L2-L8)
A - Capacity of indoor units
A - Capacity of indoor units
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
199
AM
AZ
ON
IND
US
TRIA
L V
RF
SAMPLE OF AMAZON IV PRO INSTALLATION WITH 3 OUTDOOR MODULES
TOTAL CAPACITY OF OUTDOOR
UNITS (HP)
LENGTH TOTAL EQUIVALENT OF LIQUID PIPE <90m LENGTH TOTAL EQUIVALENT OF LIQUID PIPE ≥90m
GAS LIQUID 1st DIstRIBUtOR (A) GAS LIQUID 1st DIstRIBUtOR (A)
8 Ø22.2 (7/8") Ø9.5 (3/8") KCMI 100B-300B (KCMI-212) Ø22.2 (7/8”) Ø12.7 (1/2") KCMI 100B-300B (KCMI-212)
10 Ø22.2 (7/8”) Ø9.5 (3/8") KCMI 100B-300B (KCMI-212) Ø25.4 (1") Ø12.7 (1/2") KCMI 100B-300B (KCMI-212)
12-14 Ø25.4 (1") Ø12.7 (1/2") KCMI 100B-300B (KCMI-212) Ø28.6 (1 1/8") Ø15.9 (5/8") KCMI 200B-300B (KCMI-312)
16 Ø28.6 (1 1/8") Ø12.7 (1/2”) KCMI 100B-300B (KCMI-212) Ø34.9 (1 3/8”) Ø15.9 (5/8") KCMI 200B-300B (KCMI-312)
18-22 Ø28.6 (1 1/8”) Ø15.9 (5/8") KCMI 200B-300B (KCMI-312) Ø34.9 (1 3/8”) Ø19.1 (3/4") KCMI 200B-400B (KCMI-412)
24 Ø28.6 (1 1/8”) Ø15.9 (5/8") KCMI 200B-300B (KCMI-312) Ø34.9 (1 3/8”) Ø19.1 (3/4") KCMI 200B-400B (KCMI-412)
26-32 Ø34.9 (1 3/8”) Ø19.1 (3/4") KCMI 200B-300B (KCMI-312) Ø41.3 (1 5/8”) Ø22.2 (7/8") KCMI 300B-500B (KCMI-512)
36-48 Ø41.3 (1 5/8”) Ø19.1 (3/4") KCMI 200B-400B (KCMI-412) Ø41.3 (1 5/8") Ø22.2 (7/8") KCMI 300B-500B (KCMI-512)
50-64 Ø41.3 (1 5/8”) Ø22.2 (7/8") KCMI 300B-500B (KCMI-512) Ø53.9 (2 1/8”) Ø25.4 (1") KCMI 300B-500B (KCMI-512)
66-88 Ø53.9 (2 1/8”) Ø25.4 (1") KCMI 300B-500B (KCMI-512) Ø53.9 (2 1/8”) Ø25.4 (1") KCMI 300B-500B (KCMI-512)
4 Selection of drifters (L,M,N) and pipes (g1, g2, g3, g4, G1, G2) of outdoor unit. Use the next table if several modules are connected:
*Includes: gas distributor, liquid distributor and oil balance distributor.
ModuleOutd. unit
ModuleOutd. unit
ModuleOutd. unit
A
L1 A L2 B C D E F G HL3 L4 L5 L6 L7 L8
b c d e f g h i
MODULES NO DRAWING PIPE DIAMETER MODULES CONNECTION KIT*
2g1, g2:8-12 HP: 25.4 Ø / 12.7 Ø;14-22 HP: 31.8 Ø / 15.9 Ø
L :KIT KCME 12
3
g1, g2, g3:8-12 HP: 25.4 Ø / 12.7;14-22 HP: 31.8 Ø / 15.9 Ø;G1: 38.1 Ø / 19.1 Ø
L + M:KIT KCME 13
4
g1, g2, g3, g4:8-12 HP: 25.4 Ø / 12.7;14-22 HP: 31.8 Ø / 15.9 Ø;G1: 38.1 Ø / 19.1 ØG2: 41.3 Ø / 22.2 Ø
L + M+ N:KIT KCME 14
3 Selection of main pipe (L1):
Gas and liquid module pipe
Modules joint pipe Main pipe Oil balance pipe
Modules connection kit
L
L
L
M
M
N
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
200
SIZING OF PIPES
AMAZON III PRO 3 PIPES
OUTDOOR UNITS TOTAL CAPACITY (HP)
PIPES DIMENSION
KW LOW-PRESSURE GAS HIGH-PRESSURE GAS LIQUID DRIFTERS
A < 56 Ø12.7 (1/2") Ø6.35 ( 1/4”) KCMI 100B-200B-200B (KCMI-113)
56 ≤ A < 166 Ø19.1 (3/4") Ø15.9 (5/8") Ø9.53 (3/8”) KCMI 100B-200B-200B (KCMI-113)
166 ≤ A < 230 Ø22.2 (7/8") Ø19.1 (3/4") Ø9.53 (3/8”) KCMI 100B-300B-200B (KCMI-213)
230 ≤ A < 330 Ø22.2 (7/8") Ø19.1 (3/4") Ø12.7 (1/2”) KCMI 100B-300B-200B (KCMI-213)
330 ≤ A < 460 Ø28.6 (1 1/8") Ø22.2 (7/8") Ø12.7 (1/2”) KCMI 200B-300B-300B (KCMI-313)
460 ≤ A < 660 Ø28.6 (1 1/8") Ø22.2 (7/8") Ø15.9 (5/8 ”) KCMI 200B-300B-300B (KCMI-313)
660 ≤ A < 920 Ø34.9 (1 3/8") Ø28.6 (1 1/8") Ø 19.1 (3/4”) KCMI 200B-400B-300B (KCMI-413)
920 ≤ A < 1350 Ø41.3 (1 5/8") Ø34.9 (1 3/8") Ø 19.1 (3/4”) KCMI 300B-400B-500B (KCMI-513)
1350 ≤ A Ø53.9 (2 1/8") Ø41/3 (1 5/8") Ø22.2 (7/8”) KCMI 300B-400B-500B (KCMI-513)
2 Selection of main pipe (L1)
OUTDOOR UNITS TOTAL
CAPACITY (HP)
LENGTH TOTAL EQUIVALENT OF PIPES <90m LENGTH TOTAL EQUIVALENT OF PIPES ≥90m
LOW-PRESSURE GAS
HIGH-PRESSURE GAS
LIQUID 1st DISTRIBUTOR (A)LOW-
PRESSURE GAS
HIGH-PRESSURE
GASLIQUID 1st DIstRIBUtOR (A)
8 Ø22.2 (7/8") Ø19.1 (3/4") Ø3/8 (9.53) KCMI 100B-300B-200B (KCMI-213) Ø22.2 (7/8") Ø19.1 (3/4") Ø12.7 (1/2") KCMI 100B-300B-200B (KCMI-213)
10 Ø22.2 (7/8") Ø19.1 (3/4") Ø12.7 (1/2") KCMI 100B-300B-200B (KCMI-213) Ø22.2 (7/8") Ø19.1 (3/4") Ø12.7 (1/2") KCMI 100B-300B-200B (KCMI-213)
12 Ø25.4 (1") Ø19.1 (3/4") Ø12.7 (1/2") KCMI 200B-300B-300B (KCMI-313) Ø25.4 (1") Ø19.1 (3/4") Ø15.9 (5/8") KCMI 200B-300B-300B (KCMI-313)
14-16 Ø28.6 (1 1/8") Ø22.2 (7/8") Ø15.9 (5/8") KCMI 200B-300B-300B (KCMI-313) Ø28.6 (1 1/8") Ø22.2 (7/8") Ø15.9 (5/8") KCMI 200B-300B-300B (KCMI-313)
18-22 Ø34.9 (1 3/8”) Ø28.6 (1 1/8") Ø15.9 (5/8") KCMI 200B-300B-300B (KCMI-313) Ø31.8 (1 1/4") Ø28.6 (1 1/8") Ø19.1 (3/4") KCMI 200B-300B-300B (KCMI-313)
24 Ø34.9 (1 3/8") Ø28.6 (1 1/8") Ø15.9 (5/8") KCMI 200B-400B-300B (KCMI-413) Ø34.9 (1 3/8") Ø28.6 (1 1/8") Ø19.1 (3/4") KCMI 200B-400B-300B (KCMI-413)
26-32 Ø34.9 (1 3/8") Ø28.6 (1 1/8") Ø19.1 (3/4") KCMI 200B-400B-300B (KCMI-413) Ø34.9 (1 3/8") Ø28.6 (1 1/8") Ø22.2 (7/8") KCMI 200B-400B-300B (KCMI-413)
34-48 Ø41.3 (1 5/8") Ø34.9 (1 3/8") Ø19.1 (3/4") KCMI 300B-400B-500B (KCMI-513) Ø41.3 (1 5/8") Ø34.9 (1 3/8") Ø22.2 (7/8") KCMI 300B-400B-500B (KCMI-513)
50-64 Ø53.9 (2 1/8") Ø41.3 (1 5/8") Ø22.2 (7/8") KCMI 300B-400B-500B (KCMI-513) Ø44.5 (1 3/4") Ø38.1 (1 1/2") Ø25.4 (1") KCMI 300B-400B-500B (KCMI-513)
HOW TO CHOOSE THE DISTRIBUTOR AND THE REFRIGERANT PIPELINE
1 Selection of main pipe (L1 - L11):
SET REFERENCE LIQUID HIGH-PRESSURE GAS LOW-PRESSURE GAS
2 pipes KCMI 100B-200B (KCMI-112) E-100FRGb - E-200FRGb
3 pipes
KCMI 100B-200B-200B (KCMI-113) E-100FRGb E-200FRGb E-200FRGb
KCMI 100B-300B-200B (KCMI-213) E-100FRGb E-200FRGb E-300FRGb
KCMI 200B-300B-300B (KCMI-313) E-200FRGb E-300FRGb E-300FRGb
KCMI 200B-400B-300B (KCMI-413) E-200FRGb E-300FRGb E-400FRGb
KCMI 300B-400B-500B (KCMI-513) E-300FRGb E-400FRGb E-500FRGb
MODULES NO DRAWING
2
3
4
CONNECTION HIGH-PRESSURE GAS LOW-PRESSURE GAS LIQUID
g1,g2,g3,g48/10/12HP Ø7/8(22.2) Ø3/4(19.1) Ø1/2(12.7)
14/16HP Ø1-1/8(28.6) Ø7/8(22.2) Ø5/8(15.9)
G1 Ø1-3/8(34.9) Ø1-1/8(28.6) Ø3/4(19.1)
G2 Ø1-5/8(41.3) Ø1-3/8(34.9) Ø7/8(22.2)
Important: Main pipe L1 can be selected from Table 1 or from Table 2, always trying to choose the most unfavourable option.
Includes: Low-pressure gas distributor, high-pressure gas distributor, liquid distributor and oil balance distributor and high-pressure gas balance distributor.
3 Selection of outdoor unit's pipe (g1, g2, g3, g4, G1, G2)
When there is more than one module connected, please use the following table:
Design and Install for you
201
AM
AZ
ON
IND
US
TRIA
L V
RF
A - Indoor units capacity
5 Selection of the 2-DUCTS main pipe and 2-DUCTS distributor (a, g, j, k)
6 Selection of indoor unit's pipe to be connected to the distributor or the KVB (b, c, d, e, f, h, i, l, m, n)
7 Selection of KVB’s multigroup
INDOOR UNIT TOTAL CAPACITY GAS PIPE LIQUID DISTRIBUTOR
A<166 Ø15.9 (5/8”) Ø9.53 (3/8”) KCMI 100B-200B (KCMI-112)
INDOOR UNIT CAPACITYSELECTION OF INDOOR UNIT'S PIPE TO B
CONNECTED TO THE DISTRIBUTOR OR TO THE KVB (KVB≤10M)
SELECTION OF INDOOR UNIT'S PIPE TO B CONNECTED TO THE DISTRIBUTOR OR TO THE KVB
(KVB>10M)
KW GAS PIPE LIQUID GAS PIPE LIQUID
A<56 Ø12.7 (1/2”) Ø6.35 (1/4”) Ø15.9 (5/8”) Ø9.53 (3/8”)
56≤A≤166 Ø15.9 (5/8”) Ø9.53 (3/8”) Ø19.1 (3/4”) Ø12.7 (1/2”)
200 Ø9.5 (3/8”) Ø22.2 (7/8") Ø12.7 (1/2”) Ø25.4 (1")
250 Ø12.7 (1/2”) Ø22.2 (7/8")
280 Ø12.7 (1/2”) Ø22.2 (7/8")
400 Ø12.7 (1/2”) Ø28.6 (1 1/8”)
450 Ø12.7 (1/2”) Ø28.6 (1 1/8”)
560 Ø15.9 (5/8") Ø28.6 (1 1/8")
4 Selection of the modules connection kit (L, M, N)
OUTDOOR MODULES NO CONNECTED TO COOLING DISTRIBUTORS
2 units L:KIT KCMER 32
3 units L+M:KIT KCMER 33
4 units L+M+N:KIT KCMER 34
Modules T-Type distributor g1, g2, g3, G1
MODEL NO
EACH GROUP EACH KVB
CAPACITY QUANTITY CAPACITY QUANTITY
Max. IU Max. IU Max. IU Max. IU
KVBM2 DN3 16kw
4
28kw 8
KVBM4 DN3 16kw 45kw 16
KVBM6 DN3 16kw 45kw 24
PIPE TYPE CODE
Main pipe L13-DUCTS pipe L2-L112-DUCTS pipe a, b, ….n
3-DUCTS distributor A,B,C,D,E2-DUCTS distributor I,II,III,IV
Modules connecting distrib. L,MModules T-Type pipe g1,g2,g3, G1KVB inverter boxes KVB1, …KVB6
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
202
SIZING OF PIPES
DISTANCES AND HEIGHT DIFFERENCES 2 PIPES
AMAZON IV PRO ALL MODULES
PIPING LENGTH
Total length from outdoor unit to all the indoor units. ≤ 1000m
Length between the outdoor unit and the furthest indoor unit.
Real ≤ 175m
Equivalent ≤ 200m
Length between the first distributor and the furthest indoor unit. ≤ 40 (90m*)
Length between one indoor unit and the closest distributor -
HEIGHT DIFFERENCE
Level difference between outdoor
unit and indoor unit
The outdoor unit is higher
than the indoor unit ≤ 110m
The outdoor unit is lower
than the indoor unit ≤90m
Level difference between indoor units ≤ 30m
MINI AMAZON II 8/10,5 KW 12/14/16/18KW
PIPING LENGTH
Total length from outdoor unit to all the indoor units. ≤100m
Length between the outdoor unit and the furthest indoor unit.
Real ≤45m ≤60m
Equivalent ≤50m ≤70m
Length between the first distributor and the furthest indoor unit. ≤20 (40m*)
Length between one indoor unit and the closest distributor 15m
HEIGHT DIFFERENCE
Level difference between outdoor unit
and indoor unit
The outdoor unit is higher
than the indoor unit ≤30m
The outdoor unit is lower
than the indoor unit ≤20m
Level difference between indoor units ≤8m
AMAZON III W 8/10/12 HP
PIPING LENGTH
Total length from outdoor unit to all the indoor units. ≤300m
Length between the outdoor unit and the furthest indoor unit.
Real ≤120m
Equivalent ≤150m
Length between the first distributor and the furthest indoor unit. ≤40 (90 m*)
Length between one indoor unit and the closest distributor -
HEIGHT DIFFERENCE
Level difference between outdoor
unit and indoor unit
The outdoor unit is higher
than the indoor unit ≤50m
The outdoor unit is lower
than the indoor unit ≤40m
Level difference between indoor units ≤30m
*Check for lengths between 20 and 40 metres.
*Check for lengths between 40 and 90 metres.
*Check for lengths between 40 and 90 metres.
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
203
AM
AZ
ON
IND
US
TRIA
L V
RF
OUTDOOR UNIT
INDOOR UNITS
AMAZON III W
30 m
40m (90m)
110m
200 m
OUTDOOR UNIT
INDOOR UNITS
MINI AMAZON II
8 m
20m (40m)
30m
50m (70m)
OUTDOOR UNIT
INDOOR UNITS
AMAZON III W
30 m
40m (90m)
50m
150 m
AMAZON III W
AMAZON IV PRO
MINI AMAZON II
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
204
SIZING OF PIPES
DISTANCES AND HEIGHT DIFFERENCES 2 PIPES
AMAZON UNITARIO TOP AIR DISCHARGE 10-16 HP 20/22/24 HP
PIPING LENGTH
Total length from outdoor unit to all the indoor units. ≤350m ≤1000m
Length between the outdoor unit and the furthest indoor unit.
Real ≤150m ≤175m
Equivalent ≤175m ≤200m
Length between the first distributor and the furthest indoor unit. ≤40 ≤40 (90m*)
Length between one indoor unit and the closest distributor ≤15 ≤15
HEIGHT DIFFERENCE
Level difference between outdoor unit
and indoor unit
The outdoor unit is higher
than the indoor unit ≤70m ≤110m
The outdoor unit is lower
than the indoor unit ≤50m ≤70m
Level difference between indoor units ≤15m ≤30m
AMAZON UNITARIO SIDE AIR DISCHARGE 20/22/24 KW 40/45 KW
PIPING LENGTH
Total length from outdoor unit to all the indoor units. ≤120m ≤250m
Length between the outdoor unit and the furthest indoor unit.
Real ≤60m ≤100m
Equivalent ≤70m ≤120m
Length between the first distributor and the furthest indoor unit. ≤20m ≤40 m
Length between one indoor unit and the closest distributor ≤15m ≤15m
HEIGHT DIFFERENCE
Level difference between outdoor unit
and indoor unit
The outdoor unit is higher
than the indoor unit ≤30m ≤30m
The outdoor unit is lower
than the indoor unit ≤20m ≤20m
Level difference between indoor units ≤8m ≤8m
*Check for lengths between 40 and 90 metres.
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
205
AM
AZ
ON
IND
US
TRIA
L V
RF
OUTDOOR UNITS
INDOOR UNITS
AMAZON III W
30 m
40m (90m)
50m
150 m
OUTDOOR UNIT
INDOOR UNITS
MINI AMAZON II
8 m
20m (40m)
30m
70m (120m)
AMAZON UNITARIO SIDE AIR DISCHARGE
AMAZON UNITARIO TOP AIR DISCHARGE
Go back to General Contents Go back to AMAZON Index(Index)
INDUSTRIAL VRF RANGE
206
SIZING OF PIPES
AMAZON III PRO 3-PIPES
AMAZON III PRO ALL MODULES
PIPING LENGTH
Total length from outdoor unit to all the indoor units. ≤1000 m
Length between the outdoor unit and the furthest indoor unit.
Real ≤175 m
Equivalent ≤200 m
Length between the first distributor and the furthest indoor unit.
≤40m (90 m)
HEIGHT DIFFERENCE
Level difference between outdoor unit
and indoor unit
The outdoor unit
is higher than the
indoor unit
≤110m
The outdoor unit
is lower than the
indoor unit
≤ 70 m
Level difference between indoor units ≤ 30 m
*Length between the KVB box and the furthest indoor unit. 40 m.
*Check for lengths between 40 and 90 metres.
DISTANCES AND HEIGHT DIFFERENCES 3 PIPES
Go back to General Contents Go back to AMAZON Index(Index)
Design and Install for you
207
AM
AZ
ON
IND
US
TRIA
L V
RF
AMAZON III PRO
OUTDOOR UNIT
INDOOR UNITS
30 m
40m (90m)
110m
200 m
Go back to General Contents Go back to AMAZON Index(Index)
209
Design and Install for you
INTRODUCTION TO THE PRODUCT RANGE ......................................210
UNITS
INDIVIDUAL WIRELESS AND WIRED CONTROLLERS ................212
CENTRALISED........................................................................... .....214
BMS & SOFTWARE ........................................................................216
ACCESSORIES ................................................................................224
CONTROLSCONTROL SYSTEM RANGE
CONTROLSCONTROL SYSTEM RANGE
210
CONTROL SYSTEMSRANGE
INTRODUCTION TO THE RANGE OF PRODUCTS
Introducing the 2017 KAYSUN UK controllers' range, where we would like to highlight our cutting-edge wireless controllers and their enhanced functions, such as a built-in ambient sensor, a self-cleaning function and the remote control lock button, among others. Among all these controllers, the most outstanding are the KID-02 S, included in SUITE and ZEN units. This wireless controller is able to interact with some of the models in order to provide working parameters, which could be partly modified without accessing the electronic board of the unit. In wired controllers, the most outstanding is the KC-03 SPS, a bidirectional controller with a renewed appearance, communication through just 2 non-polarised wires and fitted with the best features, such as alarm codes and a weekly timer.
Furthermore, KAYSUN UK offers a complete range of interfaces for BMS Lonworks, Bacnet, Modbus and KNX, as well as a gateway KAYSUN-Airzone or the Kaynet control, a software for managing KAYSUN UK cooling systems by computer. Finally, we would like to introduce the KCC-64 WEB controller, a device that allows the remote control of 64 indoor units through the Internet by Smartphone, Tablet or PC.
Always at the forefront regarding aesthetics and functionality, the KC-03 SPS can control up to 16 indoor units as a group with only two communication wires. It is fitted with a weekly timer and includes the Follow me function, which helps control the start/stop function of the unit from the controller's sensor. It is compatible with most units of the SUITE and ZEN range.
In 2016, KAYSUN UK unveiled its K03 USB WiFi control device for the wall-mounted units of the SUITE range: In 2017, KAYSUN UK will unveil its new adaptor for units in the ZEN range. These accessories connect the unit to our domestic WiFi network and control it through an App installed on our smartphone. The application also includes a weekly timer built into the App to ease and improve the control function of our air-conditioning system.
For the SUITE and ZEN ranges. Among the features of this new control, we would like to emphasise its capability to read operating data on most units, such as the room temperature, pipeline temperature, discharge temperature, the compressor's energy consumption, and so on. Moreover, it allows the user to change the operating parameters of said units and to activate the Auto Restart function, change the compensation temperature, configure the fan to stop, etc. All these features allow the installation engineer to adapt the unit more easily to the spaces to be climate controlled, and makes it easier to control the operation of the unit during service tasks. We would like also to stress that this new control is fitted with the corresponding keys to activate/deactivate the following options: SILENCE, 8º HEATING, FOLLOW ME and AUTO-CLEANNING modes, provided that the indoor unit is compatible with it.
CONTROL SYSTEMS RANGE CONTROLS
KC-03 SPSWIFI ADAPTORS
KID-02 S
"COMPREHENSIVE SOLUTIONS AT YOUR
FINGERTIPS"
NEW
Go back to General Contents Go back to CONTROLS Index(Index)
211
Design and Install for you
CON
TR
OLS
CON
TRO
L S
YS
TEM
S
AMAZON
AMAZON
AMAZON
AMAZON
AMAZON
ZEN
ZEN
ZEN
ZEN
ZEN
SUITE
SUITE
SUITE
SUITE
SUITE
KI-02.3 S
KID-02 S
KC-01 S
KC-02.1 H
KC-03 SPS
KCT-02.1 SR
KMC-32 E
KCC-16
KCC-64 WEB
K01-LON
K01-WATT
INTERFACEXYE ON
INDIVIDUAL WIRELESS
ACCESSORIES
INDIVIDUAL WIRED
CENTRALISED
BMS AND SOFTWARE
COMPATIBILITY PRODIGY 1X1
PRODIGY 1X1
PRODIGY 1X1
PRODIGY 1X1
PRODIGY 1X1
AUREA II 1X1
AUREA II 1X1
AUREA II 1X1
AUREA II 1X1
AUREA II 1X1
ONNIX 1X1
ONNIX 1X1
ONNIX 1X1
ONNIX 1X1
ONNIX 1X1
MULTI
MULTI
MULTI
MULTI
MULTI
KSD 1X1
KSD 1X1
KSD 1X1
KSD 1X1
KSD 1X1COMPATIBILITY
COMPATIBILITY
COMPATIBILITY
COMPATIBILITY
OUR RANGE OF PRODUCTS
KCC-64 I-PS
KCCT-64 I
K03-MODBUS
K02-MODBUS
K01-BACNET
KAHU
KAYNET CONTROL
K01-KNX
K01-WIFI
NEW
Except for Cassette 840x840
Except for Cassette 840x840
Except for Cassette 840x840
Except for Aurea II, Onnix and KCIS 840x840
Except for Aurea II, Onnix and KCIS 840x840
Except for Aurea II, Onnix and KCIS 840x840
Ducts and cassette type only
Ducts and cassette type only
Except for wall-mounted units
Except for wall-mounted units
Except for wall-mounted units
Except for wall-mounted units
Except for wall-mounted units
Except for wall-mounted units
Except for wall-mounted units
Except for wall-mounted units
Except for wall-mounted units
Only KSD
Except for MINI AMAZON II
Except MINI AMAZON II and AMAZON III PRO
3 ducts
Go back to General Contents Go back to CONTROLS Index(Index)
212
CONTROL SYSTEMSRANGE
INDIVIDUAL WIRELESS AND WIRED
CONTROLLERS
• Wireless controller.• FOLLOW ME.• LED function.• Turbo function.• Silence function.• Night mode.• 8 ºC function.• Self-cleaning function.• Units operating parameters query.• Units operating parameters change. • Mute function.
KID-02 S
INDIVIDUAL WIRELESS AND WIRED
GENERAL CHARACTERISTICS
KI-02.3 S
• Wireless controller.• FOLLOW ME.• 26ºC function.• AMAZON indoor units addressing.• AUTO mode activation/deactivation.
GENERAL CHARACTERISTICS
KC-01 S
• Wired controller.• FOLLOW ME.
GENERAL CHARACTERISTICS
PRICE LIST
MODEL COMPATIBLE WITH PRICE
KID-02 S SUITE - ZEN £16
Check available functions for each unit.
Standard in Prodigy, Onnix and Aurea II ranges.
PRICE LIST
MODEL COMPATIBLE WITH PRICE
KI-02.3 S AMAZON £22
PRICE LIST
MODEL COMPATIBLE WITH PRICE
KC-01 SSUITE*
ZEN**
AMAZON
£38
* Except for Aurea II, Onnix and Cassette 840x840
** Except Cassette 840x840
Go back to General Contents Go back to CONTROLS Index(Index)
213
Design and Install for you
CON
TR
OLS
CON
TRO
L S
YS
TEM
S
KC-03 SPS
• Wired controller with 2 non-polarised wires.
• FOLLOW ME.• Malfunction codes display.• Weekly timer.• Capacity to control up to
16 indoor units.• Bidirectional.
GENERAL CHARACTERISTICS
KC-02.1 H
• Wired controller.• Hotel-type simplified controller
with Operation mode function hidden.
• 26ºC function.• Memory function.
HOTEL SPECIAL
GENERAL CHARACTERISTICS
KCT-02.1 SR
• Wired controller. • FOLLOW ME.• Touch control.• AMAZON indoor units addressing.• Filter cleaning alarm.• Built-in infrared signal receiver.• Memory function.
GENERAL CHARACTERISTICS
PRICE LIST
MODEL COMPATIBLE WITH PRICE
KC-03 SPSSUITE*
ZEN£43
* Except for wall-mounted and KSD models
PRICE LIST
MODEL COMPATIBLE WITH PRICE
KC-02.1 HSUITE*
ZEN**
AMAZON
£46
PRICE LIST
MODEL COMPATIBLE WITH PRICE
KCT-02.1 SRSUITE*
ZEN**
AMAZON
£58
* Except for Aurea II, Onnix and Cassette 840x840
** Except Cassette 840x840
* Except for Aurea II, Onnix and Cassette 840x840
** Except Cassette 840x840
OPTIONALMOTORIZED PANEL
COMPATIBLE WITH
Go back to General Contents Go back to CONTROLS Index(Index)
214
CONTROL SYSTEMSRANGE
CENTRALISED
KCCT-64 I
• Touch control.• Indoor centralised controller.• Up to 64 indoor units• Emergency stop.
KMC-32 E
• Centralised display for outdoors.• Up to 32 modules.• If outdoor unit is fitted with the K01-WATT
wattmeter, total consumption of each module is displayed.
KCC-64 I-PS
• Indoor centralised controller.• Up to 64 indoor units.• Emergency stop.• Weekly timer.• Non-compatible with superior controls.
CENTRALISED
GENERAL CHARACTERISTICS
GENERAL CHARACTERISTICS
GENERAL CHARACTERISTICS
PRICE LIST
MODEL COMPATIBLE WITH PRICE
KCCT-64 ISUITE*
ZEN
AMAZON
£308
PRICE LIST
MODEL COMPATIBLE WITH PRICE
KMC-32 E AMAZON £154
PRICE LIST
MODEL COMPATIBLE WITH PRICE
KCC-64 I-PSSUITE*
ZEN
AMAZON
£246
*except wall-mounted units
*except wall-mounted units
Go back to General Contents Go back to CONTROLS Index(Index)
215
Design and Install for you
CON
TR
OLS
CON
TRO
L S
YS
TEM
S
KCC-16
KCC-64 WEB
• Indoor centralised controller.• Up to 16 indoor units.• On/Off for individual units and Operating
mode change.• Non-compatible with superior controls.• Compatible with other centralised controls.
• Units control through WEB or Smartphone APP.• Indoor centralised controller.• Up to 64 indoor units.• Weekly timer.• Non-compatible with superior controls.
GENERAL CHARACTERISTICS
GENERAL CHARACTERISTICS
PRICE LIST
MODEL COMPATIBLE WITH PRICE
KCC-16SUITE*
ZEN
AMAZON
£92
PRICE LIST
MODEL COMPATIBLE WITH PRICE
KCC-64 WEBSUITE*
ZEN
AMAZON
£616
*except wall-mounted units
*except wall-mounted units
Go back to General Contents Go back to CONTROLS Index(Index)
216
BMS AND SOFTWARECONTROL SYSTEMS
RANGE
K01-LON
• BMS interface, direct gateway to Lonworks.• Centralised controllers not required.• Up to 64 combinable indoor units.
K01-LON
UP TO 64 INDOOR UNITS
SYSTEM 1
SYSTEM 2
X,Y,E P,Q,E
P,Q,E
P,Q,ESYSTEM NLONWORKSBMS
BMS AND SOFTWARE
INSTALLATION EXAMPLE
GENERAL CHARACTERISTICS
PRICE LIST
MODEL COMPATIBLE WITH PRICE
K01-LONSUITE*
ZEN
AMAZON
£2,464
*except wall-mounted units
Go back to General Contents Go back to CONTROLS Index(Index)
217
Design and Install for you
CON
TR
OLS
CON
TRO
L S
YS
TEM
S
K02-MODBUS
K03-MODBUS
• BMS interface, direct gateway to MODBUS through RTU and TCP/IP.• Up to 64 indoor units and 4 outdoor units of the same cooling system.• Centralised controllers not required.
• BMS interface, direct gateway to MODBUS RTU (RS-485). • Connection to HA and HB.• Direct connection to the indoor unit.• One interface per unit (MODBUS 1x1).
INSTALLATION EXAMPLE
GENERAL CHARACTERISTICS
GENERAL CHARACTERISTICS
OUTDOOR UNITS
UP TO 64 INDOOR UNITS
HASTA 4 UNIDADES EXTERIORES
K02-MODBUS
P,Q,E
K1,K2,E
K1,K2,E
X,Y,E
MODBUSBMS
UP TO 4 OUTDOOR UNITS OF THE SAME COOLING SYSTEM
RTU (RS-485) HA,HB
INSTALLATION EXAMPLE
PRICE LIST
MODEL COMPATIBLE WITH PRICE
KO2-MODBUSSUITE*
ZEN
AMAZON
£2,464
PRICE LIST
MODEL COMPATIBLE WITH PRICE
K03-MODBUSSUITE*
ZEN
Price on application
*except wall-mounted units
*Except for wall-mounted and KSD models
Go back to General Contents Go back to CONTROLS Index(Index)
218
BMS AND SOFTWARECONTROL SYSTEMS
RANGE
K01-BACNET
• Direct BMS interface to BACNET.• 4 ports available for indoor and outdoor units. • Up to 256 indoor units.• Up to 128 outdoor units.
HUB
XYE
XYE
CON IP MONITORED SYSTEM BACNET IP PROTOCOLBMS
OUTDOOR UNITS
OUTDOOR UNITS
K01-BACNET
K1,K2,E P,Q,E
P,Q,E
INDOOR UNITS
INDOOR UNITS
BMS AND SOFTWARE
INSTALLATION EXAMPLE
GENERAL CHARACTERISTICS
PRICE LIST
MODEL COMPATIBLE WITH PRICE
K01-BACNETSUITE*
ZEN
AMAZON
£2,464
*except wall-mounted units
Go back to General Contents Go back to CONTROLS Index(Index)
219
Design and Install for you
CON
TR
OLS
CON
TRO
L S
YS
TEM
S
K01-KNX
• BMS interface, direct gateway to KNX.• Centralised controllers not required.• Three interface types, 1, 16 or 64 indoor units.
INSTALLATION EXAMPLE
GENERAL CHARACTERISTICS
KNX CONTROL SYSTEM
INDOOR UNITS
P.Q.E P.Q.E
XYE XYE XYE
KO1-KNX 1 KO1-KNX 1 KO1-KNX 1
P.Q.E
OUTDOOR UNIT
PRICE LIST
MODEL COMPATIBLE WITH PRICE
KO1-KNX 1SUITE*
ZEN
AMAZON
£252
KO1-KNX 16 £1,694
KO1-KNX 64 £3,264
*except wall-mounted units
Go back to General Contents Go back to CONTROLS Index(Index)
220
BMS AND SOFTWARECONTROL SYSTEMS
RANGE
K01-WIFI
• The user connects via a web page or APP for IOS or Android and controls the air-conditioning units in an easy and intuitive way. A cloud server manages the whole process.
• Centralised controllers not required.• Designed for controlling just one unit• Collaboration agreement with Intesis Home.
INSTALLATION EXAMPLE
BMS AND SOFTWARE
THE COMMAND IS SENT FROM OUR DEVICE
1 2
1
2
K01-WIFI device
External antenna
+
INFORMATION IS TRANSFERRED THROUGH THE CLOUD SERVER
A CONVENTIONAL ROUTER RECEIVES THE COMMAND
IT SENDS THE SIGNAL TO OUR UNITSTHE INDOOR UNIT RUNS THE COMMAND
1 2
3 4
*INFRARED DEVICE
GENERAL CHARACTERISTICS
SMARTPHONE PC TABLET
PRICE LIST
MODEL COMPATIBLE WITH PRICE
K01-WIFISUITE
ZEN
AMAZON
£178
Go back to General Contents Go back to CONTROLS Index(Index)
221
Design and Install for you
CON
TR
OLS
CON
TRO
L S
YS
TEM
S
¿HOW DOES IT WORK?
WHAT DO YOU NEED?
DOES IT TAKE UP SPACE ON MY MOBILE DEVICE?
TURN YOUR EQUIPMENT ON AND OFF+CHANGE THE FUNCTION (HEAT, COOL, DRY...)+CONTROL THE POSITION OF THE LOUVRES+DISPLAY THE TEMPERATURE IN YOUR HOUSE +
Control all the Air Conditioning units via the Internet from a website or from an application for your Smartphone or Tablet.
• Switch on the Air Conditioning before arriving home.
• Change the automatic switch on programme if you are going to arrive later.
• Know the temperature in the rooms of your house at all times.
You only need to install a small device into your air-conditioning unit to begin remotely controlling your units. The WIFI router at your place will send your commands.
No! All the information necessary for the operation of the new K01-WIFI control is stored in the cloud during the process.
REMOTE CONTROLLEROF YOUR
AIR CONDITIONER
ADVANTAGES
K01-WIFI
SMARTPHONE PC TABLET
INSTANT CONTROL ANYWHERE
OPERATION INTERFACE EXAMPLE
Go back to General Contents Go back to CONTROLS Index(Index)
222
BMS AND SOFTWARECONTROL SYSTEMS
RANGE
• A KAYSUN solution for a comprehensive control of your units.• Up to 16 cooling circuits.• Up to 256 indoor units.• Up to 64 outdoor units.• Centralised controllers not required.• Simple Web control though IP or software.• Network control software included.
KAYNET CONTROL
BMS AND SOFTWARE
GENERAL CHARACTERISTICS
INSTALLATION EXAMPLE
PRICE LIST
MODEL COMPATIBLE WITH PRICE
KAYNET CONTROL
SUITE*
AMAZON
ZEN
£3,696
*except wall-mounted units
Go back to General Contents Go back to CONTROLS Index(Index)
223
Design and Install for you
CON
TR
OLS
CON
TRO
L S
YS
TEM
S
BUILDING LAYOUT CONSUMPTION CONTROL AND RECORD
MAIN DISPLAY SCHEDULE
GROUPS LIMITATION/BLOCK
START AND STOP RECORD COMMANDS AND ACCESSES RECORD
224
CONTROL SYSTEMSRANGE
ACCESSORIES
• Interface to connect a cooling unit with a direct expansion heat exchanger to the AMAZON (VRF) systems.
• It has an additional indoor unit.• Power from 9 to 56 kW.• More than one unit can be connected at the same time to
increase the connectable capacity.
ACCESSORIES
KAHU NEW
INSTALLATION EXAMPLE
GENERAL CHARACTERISTICS
KAHU
MARKET CLIMATE CONTROL
INDOOR UNITS
OUTDOOR UNIT
PQE
WITH DIRECT EXPANSION BATTERY
Liquid cooling pipeline
Gas cooling pipeline
PRICE LIST
MODEL COMPATIBLE WITH PRICE
KAHU-200.2
AMAZON
£308
£369KAHU-360.2
KAHU-560.2 £492
Go back to General Contents Go back to CONTROLS Index(Index)
225
Design and Install for you
CON
TR
OLS
CON
TRO
L S
YS
TEM
S
• Digital wattmeter.• One controller for each outdoor module.• Consumption can be displayed through the KMC-32 E and
KAYNET controllers.
• This interface is necessary to connect the KSD-35 unit to a centralised controller.
K01-WATT
INTERFACE XYE ON
KO1-WATT KO1-WATT KO1-WATT KO1-WATT
O, A
, E P
OR
T
INDOOR UNITS
OUTDOOR UNITS
INSTALLATION EXAMPLE
O, A
, E P
OR
T
O, A
, E P
OR
T
O, A
, E P
OR
T
GENERAL CHARACTERISTICS
GENERAL CHARACTERISTICS
INTERFACE XYE ON
PQE
PRICE LIST
MODEL COMPATIBLE WITH PRICE
K01-WATT AMAZON £308
PRICE LIST
MODEL COMPATIBLE WITH PRICE
INTERFACE XYE ON
KSD £56
Go back to General Contents Go back to CONTROLS Index(Index)
227
Design and Install for you
INTRODUCTION TO THE PRODUCT RANGE ................................................ ..228
CHILLERS ........................................................................................................ ..232
MINICHILLERS .............................................................. KEM D(V)(T)N ......... ..234
MODULAR FULL DC INVERTER CHILLERS ................ KEM DNS3 ............... ..236
DIGITAL SCROLL MODULAR CHILLERS ..................... KEM DHN3 .............. ..238
EXTERNAL HYDRAULIC KITS ..................................... KH ..............................240
FIXED SCROLL MODULAR CHILLERS.. ...................... KEM HN3 ................... 242
SCREW CHILLERS ........................................................ KEX - A (W) ...............244
CENTRIFUGAL CHILLERS ................................................................................248
NEXUSCHILLERS RANGE
228
CHILLERS RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
CHILLERS RANGENEXUS
This year, KAYSUN UK will unveil its new Full DC Inverter models. This range will have a power of 30 and 60 kW in two versions. Modular units that can be combined in groups of up to 4 (a total maximum capacity of 240 kW) and units with a built-in hydraulic kit.
This new range complements the multiple KAYSUN UK chiller options already available.
The range of KAYSUN UK Nexus chillers is the ideal solution for a great variety of spaces that require climate control, such as hotels, offices, stores and other facilities. All units in this range use environmentally and ozone-friendly refrigerant.
MODULAR CHILLERS
KAYSUN UK offers a wide range of modular units, which provide great versatility based on its basic modules divided into 3 sub-ranges. Each of these sub-ranges has combinable units with different power levels. These units adapt to the needs of every customer and location, with capacities ranging from 30 kW (using just one module with a lower capacity) to 1000 kW (bringing together four 250 kW chillers).
MODULAR FULL DC INVERTER CHILLERS
New modular 30kW and 60kW chillers fitted with Full DC Inverter technology. Up to four modules of these units can be combined, allowing us to achieve capacities of up to 240 kW. Fitted with DC Inverter Twin Rotary compressors and DC Brushless ventilators to ensure high efficiency and with the resulting energy savings. Units designed to ensure easy access for correct maintenance and with a compact structure.
“THE FLOW OF THE MOST ADVANCED
TECHNOLOGY”
EXCHANGER TYPE These units are fitted with a plate exchanger.
OUTLET WATER
INLET WATER
OUTLET REFRIGERANT
INLET REFRIGERANT
HOT PLATE
NEW
TWIN ROTARY DC INVERTER COMPRESSORS
DC INVERTER VENTILATORS
COMPACT STRUCTURE
+++
Go back to General Contents Go back to NEXUS Index(Index)
229
Design and Install for you
NEX
US
CHIL
LER
S
WATER OUTLET
GAS OUTLET
GAS INLET
WATER INLET
PIPE IN PIPE SYSTEM
MULTI-TUBE SYSTEM
DIGITAL SCROLL AND FIXED SCROLL EXCHANGER
Digital Scroll chillers are fitted with a pipe in pipe heat exchanger for the 30kW units and with a multi-tube heat exchanger for 65kW units. Fixed Scroll chillers are fitted with a multi-tube heat exchanger.
The 30kW and 65kW chiller units are equipped with a Digital Scroll compressor plus fixed Scroll compressors. Thanks to this advanced technology it is possible to have a total control over the part-load regime of the system. The Digital Scroll compressor, with 20 second charge and discharge cycles, allows for the compressor to work continually and adapt to the needs of the user thanks to the measurement of the return water temperature.
DIGITAL SCROLL x4 COMBINABLE UNITS UP TO 260 kW FIXED SCROLL
The 130kW, 185kW and 250kW fixed Scroll chillers, can be also combined with four 250 kW units, thereby achieving 1MW of maximum cooling power.
CONDENSATION CONTROL
Condensation control integrated into all Digital Scroll and Fixed Scroll modular chillers, (from 30 to 250 kW), which allows for operation under air temperatures down to -10ºC in Cooling mode.
REFRIGERANTE
AGUA
COMBINABLE UP TO 1000 kWx4
WATER
REFRIGERANT
Go back to General Contents Go back to NEXUS Index(Index)
230
CHILLERS RANGE INTRODUCTION TO THE RANGE
OF PRODUCTS
INVERTER MINI CHILLERS
FULL DC INVERTER CHILLER UNITS WITH BUILT-IN HYDRAULIC KIT
New 30kW and 60kW Full DC Inverter chillers with built-in hydraulic kit. These units are fitted with DC Inverter Twin Rotary compressors and DC Brushless ventilators to ensure high efficiency and the resulting energy savings. Chillers designed to ensure easy access for correct maintenance and with a compact structure.
NEW
TWIN ROTARY DC INVERTER COMPRESSORS
DC INVERTER VENTILATORS
++
COMPACT STRUCTURE
BUILT-IN HYDRAULIC KIT
++
INVERTER MINI CHILLERS
Minichiller units with 5, 7, 10, 12, 14 and 16 kW rotary Inverter compressors provide up to 3.39 EER and up to 3.50 COP. This enhancement turns these units into a very efficient option to be considered for residential hot water installations.
EXCHANGER TYPE
These units are fitted with a plate exchanger.
HYDRAULIC KIT
Minichiller units are delivered with a complete built-in hydraulic kit.
ROTARY SCREW CHILLERS
KAYSUN’S NEXUS range has large chillers with screw compressors. These units can operate condensed by air or water. Besides, all units are fitted with Bitzer bi-screw compressors and regulate refrigerant through an electronic expansion valve. These units have a capacity of between 340 and 1780 kW. They also incorporate multi-tubular evaporators and control is carried out using a microprocessor with a 10.7” touchscreen.
OUTLET WATER
INLET WATER
OUTLET REFRIGERANT
INLET REFRIGERANT
HOT PLATE
Go back to General Contents Go back to NEXUS Index(Index)
232
CHILLERS RANGE INTRODUCTION TO THE RANGE
OF PRODUCTS
POWER RANGE
5
5
5
340
14
14
225
14
540
12
12
200
12
500
10
10
180
10
440
20
20
300
20
690
INVERTER MINICHILLERS 7
7
130
7
380
16
16
250
16
600
WITHOUT HYDRAULIC KIT
AIR-WATER
SINGLE-PHASE
FIXED SCROLL
WITH HYDRAULIC KIT
DIGITAL SCROLL
WATER-WATER
THREE-PHASE
MODULARCHILLERS
SCREWCHILLERS
MODULAR FULL DC INVERTER CHILLERS
KEM-5 DVN1 KEM-7 DVN1 KEM-10 DVN KEM-12 DVN
KEM-12 DTN KEM-14 DTN KEM-16 DTN
KEX-380.1 A
KEX-340.1 AW KEX-440.1 AW KEX-540.1 AW KEX-690.1 AW
KEX-500.1 A KEX-600.1 A
KEM-130 HN3 KEM-200 HN3 KEM-250 HN3
NEW
COMBINABLE UP TO 4 MODULES
POWER kW
POWER kW
POWER kW
POWER kW
POWER kW
32 4MW
HIGH CAPACITY
CENTRIFUGALCHILLERS
CONSULT MODEL
Go back to General Contents Go back to NEXUS Index(Index)
233
Design and Install for you
NEX
US
CHIL
LER
S
30
30
400
30
805
50
50
600
50
1080
40
40
500
40
900
60
60
700
60
1385 1620
35
35
450
35
890
55
55
650
55
1200
45
45
550
45
1000
65
65
750
65
1400 1780
25
25
350
25
720
KEX-1080.2 A KEX-1200.2 A KEX-1385.2 A
KEX-900.2 A KEX-1000.2 A
KEX-805.1 AW KEX-890.1 AW KEX-1620.2 A KEX-1780.2 A
KEM-30 DNS3
KEX-720.1 A
KEM-30 DHN3 KEM-65 DHN3
Consult modelConsult model
KEM-60 DNS3
KEX-1200.2 A KEX-1400.2 A
COMBINABLE UP TO 4 MODULES
COMBINABLE UP TO 4 MODULES
6 87 95
CONSULT MODEL
Go back to General Contents Go back to NEXUS Index(Index)
234
CHILLERS RANGE MINI CHILLERS
(*) Measurement at 1 m distance and 1.5 m height. Optional KCCHT-03 wired controller
INVERTER MINICHILLERS
TECHNICAL SPECIFICATIONS
MODEL KEM-5 DVN1 KEM-7 DVN1 KEM-10 DVN KEM-12 DVN KEM-12 DTN KEM-14 DTN KEM-16 DTN
Power supply V-F-Hz 220/1/~50 220/1/~50 220/1/~50 220/1/~50 380/3/~50 380/3/~50 380/3/~50
Cooling capacitykW 5
(1.9 ~ 5.8)7
(2.1 ~ 7.8)10.0
(2.9 ~ 10.5)11.2
(3.1 ~ 12.0)11.2
(3.1 ~ 12.0)12.5
(3.3 ~ 14.0)14.5
(3.5 ~ 15.5)
kCal/h 4300 6020 8600 9632 9632 10750 12470
Cooling input kW 1.55 2.25 2.95 3.5 3.38 3.9 4.53
EER 3.23 3.11 3.39 3.20 3.31 3.20 3.20
Heating capacitykW 6.2
(2.1 ~ 7.0)8
(2.3 ~ 9.0)11.0
(3.2 ~ 12.0)12.3
(3.3 ~ 13.2)12.3
(3.3 ~ 13.2)13.8
(3.5 ~ 15.4)16.0
(3.7 ~ 17.0)
kCal/h 4730 6880 9460 10578 10578 11868 13760
Heating input kW 1.9 2.5 3.14 3.78 3.72 4.25 4.85
COP 3.26 3.20 3.50 3.25 3.31 3.25 3.30
Compressor type Rotary Rotary Rotary Rotary Rotary Rotary Rotary
No of compressors 1 1 1 1 1 1 1
Water flow rate m3/h 0.86 1.2 1.72 1.92 1.92 2.15 2.49
Max./min. water flow m3/h 0.95/0.77 1.32/1.08 1.89/1.54 2.11/1.73 2.11/1.72 2.36/1.93 2.73/2.24
Max./min. water pressure kPa 500/150 500/150 500/150 500/150 500/150 500/150 500/150
Refrigerant charge (R410A) Kg 2.5 2.5 2.8 2.8 2.8 2.9 3.2
Axial fan 1 1 2 2 2 2 2
Fan input power W 170 170 2x100 2x100 2x100 2x100 2x100
Dim. deep / wide / high mm 354x990x966 354x990x966 400x970x1327 400x970x1327 400x970x1327 400x970x1327 400x970x1327
Weight Kg 81 81 110 110 110 111 111
Sound pressure* dB (A) 58 58 59 59 62 62 62
Hydraulic connections mm DN25 (1") DN25 (1") DN32 (1 1/4") DN32 (1 1/4") DN32 (1 1/4") DN32 (1 1/4") DN32 (1 1/4")
Load loss evaporator kPa 15 15 18 18 18 18 19
Working Range ºC Cooling -5 ~ 46 / Heating -15 ~ 27
Supply water temperature ºC Cooling 4 ~ 20 / Heating 30 ~ 55
INVERTER
Calculation conditions:Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35ºC (dry bulb)Heating: inlet/outlet hot water temperature: 40/45ºC, outdoor temperature 7/6ºC (dry/wet bulb)
Go back to General Contents Go back to NEXUS Index(Index)
235
Design and Install for you
NEX
US
CHIL
LER
S
Dry contacts for start/stop, cold/heat and alarm. Connection ports for additional water pump and optional wired controller.
GENERAL CHARACTERISTICS
COMPACT DESIGN AND EASY INSTALLATION +AUTO-RESTART FEATURE+CONTROLLER INCLUDED+COMPLETE HYDRAULIC KIT +
INVERTER MINICHILLERS
PRICE LIST
INVERTER MODEL PRICE
KEM-5 DVN1 £2,173
KEM-7 DVN1 £2,375
KEM-10 DVN £3,562
KEM-12 DVN £3,802
KEM-12 DTN £3,666
KEM-14 DTN £3,817
KEM-16 DTN £4,055
Go back to General Contents Go back to NEXUS Index(Index)
236
CHILLERS RANGE FULL DC INVERTER CHILLERS
BASIC MODULES
MODULAR FULL DC INVERTER CHILLERSTECHNICAL SPECIFICATIONS
MODEL 30 DNS3 60 DNS3 90 DNS3 120 DNS3 150 DNS3 180 DNS3 210 DNS3 240 DNS3Module 30 + Module 60 1+0 0+1 1+1 0+2 1+2 0+3 1+3 0+4
Power supply V-f-Hz 380/3/~50 380/3/~50 - - - - - -
Cooling capacitykW 27.5 55 82.5 110 137.5 165 192.5 220
kCal/h 23600 47300 70900 94600 118200 141900 165500 189200
Cooling input power kW 10.9 21.8 32.7 43.6 54.5 65.4 76.3 87.2
SEERon 4.5 4.2 4.4 4.2 4.3 4.2 4.2 4.2
Heating capacity kW 31 61 92 122 153 183 214 244
kCal/h 26700 52500 79100 104900 131600 157400 184000 209800
Heating input power kW 8.50 16.05 24.55 32.1 40.6 48.15 56.65 64.2
SCOP 3.95 3.84 3.9 3.8 3.9 3.8 3.9 3.8
No. of compressors 1 2 3 4 5 6 7 8
Compressor type Double Twin Rotary DC
Number of cooling circuits 1 1 2 2 3 3 4 4
Minimum total capacity % 10% 10% 4% 5% 4% 4% 3% 3%
Evaporator Plates Plates - - - - - -
Evaporator pressure drop kPa 40 70 - - - - - -
Water flow rate m3/h 4.75 9.8 - - - - - -
Min./max. water flow m3/h 3.5~5.7 7.5~12 11~17.7 15~24 18.5~29.7 22.5~36 26~41.7 30~48
Max. water pressure MPa 1 1 1 1 1 1 1 1
Hydraulic connections Inches (mm)
11/2" (DN40) 2" (DN50) - - - - - -
Condenser Finned tube
Number of condensors 1 2 3 4 5 6 7 8
Airflow m3/h 12500 25000 - - - - - -
Control system KJRM-120H/BMWKO-E wired controller
Refrigerant load (R410A) Kg 10.5 17 - - - - - -
Number of axial venti-lators 1 2 3 4 5 6 7 8
Fan input power kW 0.75 1.5 - - - - - -
Dimensions (depth/width/height) mm 2067/805/
11522200/1065/
14602200/1870/
14602200/2130/
14602200/2935/
14602200/3195/
14602200/4000/
14602200/4260/
1460
Weight Kg 300 500 800 1000 1300 1500 1800 2000
Sound power dB (A) 78.2 83 84.2 86 86.7 87.8 88.6 89.7
Working Range ºC Cooling -15~48 / Heating -15~30
Supply water temperature ºC Cooling 0~20 / Heating 25~55
Calculation conditions:Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35ºC (dry bulb)Heating: inlet/outlet hot water temperature: 40/45ºC, outdoor temperature 7/6ºC (dry/wet bulb)
Go back to General Contents Go back to NEXUS Index(Index)
237
Design and Install for you
NEX
US
CHIL
LER
S
The new KAYSUN UK Full DC Inverter CHILLERS are available in two types of module: a 30 kW module and a 60 kW module.
The Full DC Rotary Inverter compressor and Full DC brushless ventilators provide great stability and energy efficiency.
The units are very compact and are designed to speed up maintenance.
Up to 4 modules can be combined, reaching a capacity of 240 kW.
• Full DC Inverter: The technology used in the KAYSUN UK DC INVERTERS optimises consumption, adjusting with greater accuracy to the actual demand of the system.
• Self-protection and self-diagnosis functions. Adjustment range for water outlet: from 0 to 17ºC for Cooling mode and from 22 to 50ºC for Heating mode.
• Automatic control. A single control for all the models that form the system.
• Dry contacts for start/stop, cold/ heat and alarm.
• Condensation control.
INDIVIDUAL
KCCHT-04
STANDARD CONTROLLER
KCCH-02 PS*
*Includes weekly programmer
K01-LON KEM K01- BACNET KEM*
*Requires a KCCH-02 PS
KCCHT-02 MODBUS
KCCHT-04
GENERAL CHARACTERISTICS
BMS AND SOFTWARE
SINGLE
CONTROLLER ONLY FOR AUTOMATIC CONTROL 1
OPTION WITH BUILT-IN HYDRAULIC KIT POA+
PRICE LIST
MODEL STANDARD CONTROL PRICE
KEM-30 DNS3 KCCHT-04 Price on applicationKEM-60 DNS3 KCCHT-04 Price on applicationKEM-90 DNS3 KCCHT-04 Price on applicationKEM-120 DNS3 KCCHT-04 Price on applicationKEM-150 DNS3 KCCHT-04 Price on applicationKEM-180 DNS3 KCCHT-04 Price on applicationKEM-210 DNS3 KCCHT-04 Price on applicationKEM-240 DNS3 KCCHT-04 Price on application
Go back to General Contents Go back to NEXUS Index(Index)
238
CHILLERS RANGE DIGITAL SCROLL CHILLERSDIGITAL
(*) Measurement at 1 m distance and 1.5 m height.
BASIC MODULES
DIGITAL SCROLL MODULAR CHILLERS
TECHNICAL SPECIFICATIONS
MODEL 30 DHN3 65 DHN3 95 DHN3 130 DHN3 160 DHN3 195 DHN3 225 DHN3 260 DHN3Module 30 + Module 65 1+0 0+1 1+1 0+2 1+2 0+3 1+3 0+4
Power supply V-f-Hz 380/3/~50 380/3/~50 - - - - - -
Cooling capacitykW 30 65 95 130 160 195 225 260
kCal/h 25800 55900 81700 111800 137600 167700 193500 223600
Cooling input kW 10 20.4 30.3 40.8 50.8 61.2 71.2 81.6
EER 3.00 3.19 3.14 3.19 3.15 3.19 3.16 3.20
Heating capacitykW 32 69 101 138 170 207 239 276
kCal/h 27520 59340 86860 118680 146200 178020 205540 237360
Heating input kW 9.8 21.5 31.3 43 52.8 64.5 74.3 86
COP 3.27 3.21 3.23 3.21 3.22 3.21 3.22 3.21
No. of compressors 1+1 1+2 5 6 8 9 11 12
No. of cooling circuits 2 2 4 4 6 6 8 8
Capacity control Stages Stages Stages Stages Stages Stages Stages Stages
Min. total capacity % 10 30 16 23 9.4 15 6.6 12
Evaporator Pipe in pipe Multi-tube - - - - - -
Evaporator pressure drop kPa 60 15 - - - - - -
Water flow rate m3/h 5.2 11.2 - - - - - -
Min./max. water flow m3/h 4.68/5.72 10.08/12.32 14.76/18.04 20.16/24.64 24.84/30.36 30.24/36.96 34.92/42.68 40.32/49.28
Max. water pressure MPa 1 1 1 1 1 1 1 1
Hydraulic connections Inches (mm)
1 1/2" (DN40) 4" (DN100) - - - - - -
Condenser Aluminium Fin-coil
Number of condensors 2 2 4 4 6 6 8 8
Airflow m3/h 12000 24000 - - - - - -
Control system KCCHT - 02 wired controller
Refrigerant charge (R410A) Kg 3.5x2 7x2 - - - - - -
No. of axial fans 1 2 3 4 5 6 7 8
Power input fan kW 0.67 0.865x2 - - - - - -
Dimensions (depth/width/height) mm 841x1514
x1865900x2000
x1880900x3514
x1880900x4000
x1880900x5514
x1880900x6000
x1880900x7514
x1800900x8000
x1880
Weight Kg 375 610 985 1220 1595 1830 2205 2440
Sound pressure* dB (A) 65 67 69.1 70 71.2 71.8 72.6 73
Working Range ºC Cooling -10 ~ 46 / Heating -10 ~ 21
Supply water temperature ºC Cooling 0 ~ 17 / Heating 22 ~ 50
Calculation conditions:Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35ºC (dry bulb)Heating: inlet/outlet hot water temperature: 40/45ºC, outdoor temperature 7/6ºC (dry/wet bulb)
Go back to General Contents Go back to NEXUS Index(Index)
239
Design and Install for you
NEX
US
CHIL
LER
S
KAYSUN UK Nexus Modular is available in two type of modules: one of 30kW with 2 compressors and the other of 65 kW with 3 compressors. Each unit has a "V"-type condensing coil, with a pipe in pipe exchanger for the 30kW module and a multi-tube exchanger for the 65kW module.
All models have a Digital Scroll compressor; the remaining compressors are of the fixed speed Scroll type.
Up to 4 modules can be combined, reaching a capacity of 260kW.
• Flexible combination: the connection between modules is as simple as connecting each of their inlet and outlet tubes.
• Self-protection and self-diagnosis functions. Adjustment range for water outlet: from 0 to 17ºC for Cooling mode and from 22 to 50ºC for Heating mode.
• Automatic control. A single control for all the models that form the system.
• Dry contacts for start/stop, cold/ heat and alarm.
• Condensation control.
INDIVIDUAL
KCCHT-02
KCCH-02 PS*
*Includes weekly programmer
K01-LON KEM K01- BACNET KEM*
*Requires a KCCH-02 PS
KCCHT-02 MODBUS
KCCHT-02
GENERAL CHARACTERISTICS
BMS AND SOFTWARE
SINGLE
CONTROLLER ONLY FOR AUTOMATIC CONTROL 1
STANDARD CONTROLLER
PRICE LIST
MODEL STANDARD CONTROL PRICE
KEM-30 DHN3 KCCHT-02 £6,163
KEM-65 DHN3 KCCHT-02 £9,984
KEM-95 DHN3 KCCHT-02 £16,148
KEM-130 DHN3 KCCHT-02 £19,968
KEM-160 DHN3 KCCHT-02 £26,132
KEM-195 DHN3 KCCHT-02 £29,952
KEM-225 DHN3 KCCHT-02 £36,116
KEM-260 DHN3 KCCHT-02 £39,936
Go back to General Contents Go back to NEXUS Index(Index)
240
CHILLERS RANGE EXTERNAL HYDRAULIC KITSDIGITAL
MODEL (WITH BUFFER TANK) + 1 PUMP KHX-PM3-100 KHX-A-300 KHX-B-300 KHX-C-300 KHX-D-500 KHX-F-500Buffer tank capacity litres 100 300 300 300 500 500
Expansion vessel capacity litres 18 25 25 25 25 25
Expansion vessel calibration bar 1.5 1.5 1.5 1.5 1.5 1.5
Pressure relief valve calibration bar 3 3 3 3 3 3
No. of pumps 1 1 1 1 1 1
Pump flow m3/h 5.16 11.18 16.4 22.4 27.6/31.8/33.6 38.8/43/44.8
Pressure loss mca 14.8 17 17.7 14.4 18.8/17.3/16.6 18.4/17.7/17.3
Power input kW 0.85 1.1 1.5 1.5 2.2 3
Hydraulic connections Inches 1 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 3
Power Supply V/f/Hz 230/1/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50
Dimensions Height / Width / Depth mm 1350x1120x800 1265x1504x1120 1265x1504x1120 1265x1504x1120 1265x1504x1120 1265x1504x1120
Net weight Kg 450 186 188 188 213 341
Gross weight (with water) Kg 550 486 488 488 713 841
MODEL (WITH BUFFER TANK) + DOUBLE PUMP KH2X-PM3-100 KH2X-A-300 KH2X-B-300 KH2X-C-300 KH2X-D-500 KH2X-F-500Buffer tank capacity litres 100 300 300 300 500 500
Expansion vessel capacity litres 18 25 25 25 25 25
Expansion vessel calibration bar 1.5 1.5 1.5 1.5 1.5 1.5
Pressure relief valve calibration bar 3 3 3 3 3 3
No. of pumps 2 2 2 2 2 2
Pump flow m3/h 5.16 11.18 16.4 22.4 27.6/31.8/33.6 38.8/43/44.8
Pressure loss mca 14.8 17 17.7 14.4 18.8/17.3/16.6 18.4/17.7/17.3
Power input kW 0.85 1.1 1.5 1.5 2.2 3
Hydraulic connections Inches 1 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 3
Power Supply V/f/Hz 230/1/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50
Dimensions Height / Width / Depth mm 1350x1120x800 1265x1504x1120 1265x1504x1120 1265x1504x1120 1265x1504x1120 1265x1504x1120
Net weight Kg 488 216 220 220 247 428
Gross weight (with water) Kg 588 516 520 520 747 928
MODEL (WITHOUT BUFFER TANK) + 1 PUMP KHX-PM3 KHX-A KHX-B KHX-C KHX-D KHX-FBuffer tank capacity litres - - - - - -
Expansion vessel capacity litres 12 12 12 12 12 25
Expansion vessel calibration bar 1.5 1.5 1.5 1.5 1.5 1.5
Pressure relief valve calibration bar 3 3 3 3 3 3
No. of pumps 1 1 1 1 1 1
Pump flow m3/h 5.16 11.18 16.4 22.4 27.6/31.8/33.6 38.8/43/44.8
Pressure loss mca 14.8 17 17.7 14.4 18.8/17.3/16.6 18.4/17.7/17.3
Power input kW 0.85 1.1 1.5 1.5 2.2 3
Hydraulic connections Inches 1 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 3
Power Supply V/f/Hz 230/1/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50
Dimensions Height / Width / Depth mm 1350x800x650 1350x800x650 1350x800x650 1350x800x650 1350x800x650 1350x1120x800
Net weight Kg 88 89 90 91 93 153
EXTERNAL HYDRAULIC KITS TECHNICAL SPECIFICATIONS
Go back to General Contents Go back to NEXUS Index(Index)
241
Design and Install for you
NEX
US
CHIL
LER
S
1 Tank
2 Water pump
3 Expansion vessel
5 On-off valve
6 Safety valve
7 Pressure gauge
8 Pressure relief valve
10 Automatic filling unit
11 Electric panel
12 Control valve
(version with 2 pumps only)
13 Drain
14 Anchor points
(no. 4-6 holes M12/Ø14)
15 Power Supply
16 Hoist points
17 Flow to the device
18 Return from the device
CHILLERS KEM-30 DNS3
KEM-30 DHN3
KEM-60 DNS3
KEM-65 DHN3
KEM-90 DHN3
KEM-95 DHN3
KEM-120 DNS3
KEM-130 DHN3
KEM-130 HN3
KEM-150 DNS3
Compatiblehydraulic kits*
KH-PM3 KH-PM3 KHX-A KHX-A KHX-B KHX-B KHX-C KHX-C KHX-C KHX-D
KHX-PM3-100 KHX-PM3-100 KHX-A-300 KHX-A-300 KHX-B-300 KHX-B-300 KHX-C-300 KHX-C-300 KHX-C-300 KHX-D-500
KH2X-PM3-100 KH2X-PM3-100 KH2X-A-300 KH2X-A-300 KH2X-B-300 KH2X-B-300 KH2X-C-300 KH2X-C-300 KH2X-C-300 KH2X-D-500
CHILLERSKEM-160
DHN3KEM-180
DNS3KEM-195
DHN3KEM-200
HN3KEM-210
DNS3KEM-225
DHN3KEM-240
DNS3KEM-250
HN3KEM-260
DHN3
Compatiblehydraulic kits*
KHX-D KHX-D KHX-D KHX-D KHX-F KHX-F KHX-F KHX-F KHX-F
KHX-D-500 KHX-D-500 KHX-D-500 KHX-D-500 KHX-F-500 KHX-F-500 KHX-F-500 KHX-F-500 KHX-F-500
KH2X-D-500 KH2X-D-500 KH2X-D-500 KH2X-D-500 KH2X-F-500 KH2X-F-500 KH2X-F-500 KH2X-F-500 KH2X-F-500
(*)These application tables are for guidance purposes only. The final decision is to be made by the installer.
GENERAL CHARACTERISTICS
PRICE LIST
MODEL PRICE
Tank + PumpKHX-PM3-100 £2,845KHX-A-300 £4,466KHX-B-300 £4,527KHX-C-300 £4,558KHX-D-500 £4,620KHX-F-500 £5,048Tank + 2 PumpsKH2X-PM3-100 £4,675KH2X-B-300 £5,790KH2X-A-300 £5,759KH2X-C-300 £5,821KH2X-D-500 £5,944KH2X-F-500 £6,960Without tank + PumpKHX-PM3 £2,032KHX-A £3,163KHX-B £3,187KHX-C £3,203KHX-D £3,223KHX-F £4,364
Go back to General Contents Go back to NEXUS Index(Index)
242
CHILLERS RANGE COOLERS MODEL FIXED SCROLLFIXED
33
(*) Measurement at 1 m distance and 1.5 m height.
FIXED SCROLL MODULAR CHILLERS
TECHNICAL SPECIFICATIONS
MODEL KEM-130 HN3 KEM-200 HN3 KEM-250 HN3Power Supply V-f-Hz 380/3/~50 380/3/~50 380/3/~50
Cooling capacitykW 130 185 250
kCal/h 111800 159100 215000
Cooling input kW 40.8 63 78.3
EER 3.19 2.94 3.19
Heating capacitykW 138 200 270
kCal/h 118680 172000 232200
Heating input kW 43 61 80
COP 3.21 3.28 3.38
No. of compressors 4 6 8
No. of cooling cycles 4 6 4
Min. total capacity % 25 17 25
Evaporator Multi-tube Multi-tube Multi-tube
Evaporator pressure drop kPa 25 30 40
Water flow rate m3/h 22.4 31.8 43
Min./max. water flow m3/h 18.54/22.66 27.90/34.10 38.70/47.30
Max. water pressure MPa 1 1 1
Hydraulic connections Inches (mm)
2 1/2" (DN65) 3" (DN80) 4" (DN100)
Condenser Aluminium Fin-coil
Airflow m3/h 48000 72000 96000
Control system KCCHT - 02 wired controller
Refrigerant charge (R410A) Kg 7x4 7x6 15x4
No. of axial fans 4 6 8
Fan input power kW 0.865x4 0.865x6 0.7x8
Dimensions (depth/width/height) mm 1685x2000x2080 2000x2850x2110 2000x3800x2130
Weight Kg 1150 1730 2450
Sound pressure* dB (A) 70 74 74
Working Range ºC Cooling -10 ~ 46 / Heating -10 ~ 21
Supply water temperature ºC Cooling 0 ~ 17 / Heating 22 ~ 50
Calculation conditions:Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35ºC (dry bulb)Heating: inlet/outlet hot water temperature: 40/45ºC, outdoor temperature 7/6ºC (dry/wet bulb)
Go back to General Contents Go back to NEXUS Index(Index)
243
Design and Install for you
NEX
US
CHIL
LER
S
COMBINABLE UP TO 1000 kWx4
GENERAL CHARACTERISTICS
INDIVIDUAL
KCCHT-02
STANDARD CONTROLLER
BMS AND SOFTWARE
SINGLE
The KAYSUN UK NEXUS range continues to grow and completes its range of chillers with new fixed Scroll compressor modular units of 130, 200 and 250kW each, thereby providing great solutions designed to cover the needs of our customers.
Equipped with 4, 6 and 8 compressors respectively, a "V"-type condensing coil and a multi-tube heat exchanger, these units provide a better capacity reach for the KAYSUN UK NEXUS range units.
Just as versatile as lesser capacity units, these fixed Scroll compressor modular chillers can form modules of up to 4 units, arriving to capacities of 1000 kW.
• Flexible combination: the connection between modules is as simple as connecting each of their inlet and outlet tubes.
• Self-protection and self-diagnosis functions. Adjustment range for water outlet: from 0 to 17ºC for Cooling mode and from 22 to 50ºC for Heating mode.
• Automatic control. A single control for all the models that form the system.
• Dry contacts for start/stop, cold/ heat and alarm.
• Condensation control.
• Anti-icing function.
KCCH-02 PS*
*Includes weekly programmer
K01-LON KEM K01- BACNET KEM*
*Requires a KCCH-02 PS
KCCHT-02 MODBUSKCCHT-02
PRICE LIST
MODEL STANDARD CONTROL PRICE
KEM-130 HN3 KCCHT-02 £18,412
KEM-200 HN3 KCCHT-02 £27,017
KEM-250 HN3 KCCHT-02 £36,065
Go back to General Contents Go back to NEXUS Index(Index)
244
CHILLERS RANGE SCREW CHILLERS
(*) Measurement at 1 m distance and 1.5 m height.
MODEL KEX 380.1 A KEX 500.1 A KEX 600.1 A KEX 720.1 A KEX 900.2 A KEX1000.2 A KEX1200.2 A KEX1400.2 A Power Supply V/f/Hz 380V/3P+N+PE/ 50Hz
Cooling capacitykW 376 496 594 720 902 996 1203 1419
kCal/h 323360 426560 510840 619200 775720 856560 1034580 1220340
Cooling input kW 124 159 187 234 285 318 381 466
EER 3.03 3.12 3.18 3.08 3.16 3.13 3.16 3.05
Refrigerant load (R134A) Kg 76 90 105 140 76+90 90+90 105+105 140+140
Refrigerant control ELECTRIC EXPANSION VALVE
Compressor type Semi-hermetic bi-screw compressor
No. of compressors 1 1 1 1 2 2 2 2
Oil load by compressor L 30 30 30 32 30+30 30+30 30+30 32+32
Capacity control (adjustable) % 25%, 50%, 75%, 100%, 4 steps 12.5%, 25%, 37.5%, 50%, 62.5%, 75%, 87.5%, 100%
Motor overloadprotection ELECTRONIC
Oil lubrication INJECTION
Number of fans 6 8 10 10 14 16 16 20
Airflow m3/h 23000x6 23000x8 23000x10 23000x10 23000x14 23000x16 23000x16 23000x20
Motor input power kW 2.4x6 2.4x8 2.4x10 2.4x10 2.4x14 2.4x16 2.4x16 2.4x20
Motor speed rpm 940 940 940 940 940 940 940 940
Evaporator type Multi-tube exchanger
Water volume m3 0.222 0.308 0.340 0.520 0.620 0.600 0.770 0.910
Water flow rate m3/h 65.4 86 103.2 123.8 154.8 172 206.4 244.2
Load loss kPa 39 54 56 58 74 75 71 69
Water pipe connection mm DN125 DN125 DN125 DN150 DN150 DN150 DN200 DN200
L mm 3810 4680 5800 5800 8800 9640 9640 11700
Width mm 2280 2280 2280 2280 2280 2280 2280 2280
H mm 2370 2370 2370 2370 2430 2430 2430 2430
Gross weight Kg 3320 4330 5000 5500 7750 8900 9100 11100
Working weight Kg 3540 4640 5340 6020 8370 9500 9870 12010
Outlet range ºC 5 ~ 15
Working Range ºC 15 ~ 43
1 CIRCUIT 2 CIRCUITS
AIR COOLED SCREW CHILLERS
TECHNICAL SPECIFICATIONS
Calculation conditions:Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35/24ºC (dry-/wet-bulb)
Go back to General Contents Go back to NEXUS Index(Index)
245
Design and Install for you
NEX
US
CHIL
LER
S
INVERTED "M"-SHAPED AIR CONDENSER
M
These range of chillers are equipped with 4-phase choking Bitzer bi-screw compressors.
KAYSUN UK offers 8 modules with 1 and 2 cooling circuits in order to cover an expansive capacity range, from 380 up to 1420 kW.
• Controlled by integrated microprocessor with touch screen.
• Multi-tube evaporator.
• R134a refrigerant.
• Inverted "M"-shaped air condenser
• Class "F" Isolation and IP54 protection.
GENERAL CHARACTERISTICS
PRICE LIST
MODEL PRICE
KEX 380.1 A £59,062
KEX 500.1 A £69,744
KEX 600.1 A £77,912
KEX 720.1 A £108,071
KEX 900.2 A £121,894
KEX 1000.2 A £130,691
KEX 1200.2 A £158,337
KEX 1400.2 A £182,841
Go back to General Contents Go back to NEXUS Index(Index)
246
CHILLERS RANGE SCREW CHILLERS
33
(*) Measurement at 1 m distance and 1.5 m height.
WATER-COOLED SCREW CHILLERS
TECHNICAL SPECIFICATIONS
MODEL KEX 340.1AW KEX 440.1AW KEX 540.1AW KEX 690.1AW KEX 805.1AW KEX 890.1AW KEX 1080.2AWPower Supply V/f/Hz 380V/3P+N+PE/ 50Hz
Cooling capacitykW 340 440 540 690 805 890 1080
kCal/h 292400 378400 464400 593400 692300 765400 928800
Cooling input kW 60 77 94 120 140 155 186
EER 5.67 5.71 5.74 5.75 5.75 5.74 5.81
Refrigerant load (R134A) Kg 130 145 160 200 230 250 170+170
Refrigerant control Electric expansion valve
Controller type Semi-hermetic bi-screw compressor
No. of compressors 1 1 1 1 1 1 2
Motor overload protection Electronic
Oil lubrication Through differential pressure
Evaporator Flooded multi-tube type
Water volume L 150 170 190 210 240 270 350
Water flow rate m3/h 58 76 93 119 138 153 186
Load loss kPa 55 49 53 46 39 39 78
Type of connection Victaulic
Condenser Multi-tube type
Water volume L 150 170 190 210 240 270 350
Water flow rate m3/h 73 95 116 148 173 191 232
Load loss kPa 75 70 77 66 56 56 88
Type of connection Victaulic
Evaporator type Multi-tube exchanger
Length mm 3550 3550 3550 3600 3600 3600 9640
Width mm 1200 1220 1220 1420 1440 1440 2280
H mm 1730 1800 1900 2000 2020 2020 2370
Working weight Kg 2700 2820 3220 3870 4420 4550 7250
Calculation conditions:Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35/24ºC (dry-/wet-bulb)Cooling water inlet/outlet 30/35ºC
The fouling factor of the evaporator and condenser is 0.086m2·ºC/kW
1. Input2. Motor3. Screw4. Poppet valve5. Output6. Oil separator7. Bearing8. Electric resistance
of the oil pan9. Oil filter
Go back to General Contents Go back to NEXUS Index(Index)
247
Design and Install for you
NEX
US
CHIL
LER
S
• This range includes the latest generation of semi-hermetic bi-screw compressors.
• The evaporator has a flooded multi-tube system while the condenser's system in multi-tube. Both are high-efficiency elements.
• Separate circuits for each compressor.
• The built-in control switchboard is fitted with a 7" touch screen to provide user with a comfortable and easy interaction with its interface.
• Type of refrigerant required: R134a.
• Class "F" Isolation and IP54 protection.
• Oil separation in three stages to ensure the perfect lubrication of the compressor.
• Auto-restart function to keep last configuration active.
• Refrigerant regulation through electronic expansion valve.
GENERAL CHARACTERISTICSMODEL KEX 340.1AW KEX 440.1AW KEX 540.1AW KEX 690.1AW KEX 805.1AW KEX 890.1AW KEX 1080.2AWPower Supply V/f/Hz 380V/3P+N+PE/ 50Hz
Cooling capacitykW 340 440 540 690 805 890 1080
kCal/h 292400 378400 464400 593400 692300 765400 928800
Cooling input kW 60 77 94 120 140 155 186
EER 5.67 5.71 5.74 5.75 5.75 5.74 5.81
Refrigerant load (R134A) Kg 130 145 160 200 230 250 170+170
Refrigerant control Electric expansion valve
Controller type Semi-hermetic bi-screw compressor
No. of compressors 1 1 1 1 1 1 2
Motor overload protection Electronic
Oil lubrication Through differential pressure
Evaporator Flooded multi-tube type
Water volume L 150 170 190 210 240 270 350
Water flow rate m3/h 58 76 93 119 138 153 186
Load loss kPa 55 49 53 46 39 39 78
Type of connection Victaulic
Condenser Multi-tube type
Water volume L 150 170 190 210 240 270 350
Water flow rate m3/h 73 95 116 148 173 191 232
Load loss kPa 75 70 77 66 56 56 88
Type of connection Victaulic
Evaporator type Multi-tube exchanger
Length mm 3550 3550 3550 3600 3600 3600 9640
Width mm 1200 1220 1220 1420 1440 1440 2280
H mm 1730 1800 1900 2000 2020 2020 2370
Working weight Kg 2700 2820 3220 3870 4420 4550 7250
KEX 1200.2AW KEX 1385.2AW KEX 1620.2AW KEX 1780.2AW380V/3P+N+PE/ 50Hz
1200 1385 1620 1780
1032000 1191100 1393200 1530800
206 238 278 306
5.83 5.82 5.83 5.82
180+180 190+190 210+210 220+200
Electric expansion valve
Semi-hermetic bi-screw compressor
2 2 2 2
Electronic
Through differential pressure
Flooded multi-tube type
400 460 520 580
206 238 279 306
79 79 75 76
Victaulic
Multi-tube type
400 460 520 560
258 298 348 383
87 87 85 86
Victaulic
Multi-tube exchanger
9640 11700 11700 11700
2280 2280 2280 2280
2370 2370 2370 2370
7490 7820 9200 9350
PRICE LIST
MODEL PRICE £
KEX 340.1 AW £37,591
KEX 440.1 AW £45,038
KEX 540.1 AW £51,021
KEX 690.1 AW £63,173
KEX 805.1 AW £73,629
KEX 890.1 AW £80,708
KEX 1080.2 AW £99,194
KEX 1200.2 AW £106,552
KEX 1385.2 AW £122,751
KEX 1620.2 AW £150,021
KEX 1780.2 AW £165,459
Go back to General Contents Go back to NEXUS Index(Index)
248
CHILLERS RANGE CENTRIFUGAL CHILLERS
CHILLERS RANGE
CENTRIFUGAL CHILLERS
KAYSUN UK introduces its most powerful range of chillers, thanks to the addition of centrifugal compressors.They are available in three different options according on their efficiency. From standard units to high-efficiency and, eventually, super high-efficiency units, with 7.11 EER.
All our units use R134a, an environmentally friendly refrigerant with a low GWP (Global Warming Potential), which results in maximum performance.
STANDARD EFFICIENCY
The Standard Efficiency range units are available with two different type of configurations. One consists of a power range between 1.58MW to 4.22MW, a single compression stage and a flooded multi-tube type evaporator.
The second configuration consists of two stages and a full falling film multi-tube evaporator, which results in higher cooling power, from 4.57 MW to 7.73 MW. All these units provide between 5.3 and 5.7 EER.
WHAT IS "FULL FALLING FILM"?It is the latest in refrigerant savings systems. This new concept allows using 40% less refrigerant than the traditional flooded multi-tube type evaporator, and increases the energy exchange rate between 3% and 8%.
HOW DOES IT WORK?
The liquid refrigerant falls as a liquid as rain between the pipes and evaporates as it fills the various levels of the installation.
This way, only a small percentage of refrigerant reaches the bottom of the evaporator.
“THE HIGHESTPOWER AT YOUR
SERVICE"
40% reduction in refrigerant charge
Flooded type
The falling film reaches
around 40% of the refrigerant charge
compared with the flooded type.
Full falling film
Almost 0% of liquid level
PATENTED
Go back to General Contents Go back to NEXUS Index(Index)
249
Design and Install for you
NEX
US
CHIL
LER
S
HIGH EFFICIENCY
High efficiency chillers are one-step ahead. They are divided into two different configurations. One consists of a one-stage centrifugal compressor and a flooded evaporator, which results in a power range from 2.46MW to 4.22MW. The second configuration consists of a two-stage compressor and an evaporator including the Full Falling Film system. High Efficiency units provide from 5.6 to 6.8 EER.
GUARANTEE OF SUCCESS
In order to ensure the perfect operation of its high-capacity chillers, KAYSUN UK performs tests on all of its units. This way, the company is able to guarantee that its products will comply with all the established requirements.
CONTROL PANEL
All centrifugal units are fitted with an easy to access control panel. They also include a 10.4 inches LCD touch screen to display graphic views of the chiller. The screen is easy to access. It communicates with PCs, starts and stops the unit remotely and provides more than 30 protection functions that can be checked in the 10 last failure reports.
SUPER HIGH EFFICIENCY
The KAYSUN UK Super High Efficiency range include units with 7.11 EER, which turns them into the most efficient product in the market, considering their performance. These units can reach up to 7.73 MW with a two-stage centrifugal compressor fitted with a multi-tube evaporator including the new full falling film system.
Go back to General Contents Go back to NEXUS Index(Index)
251
Design and Install for you
FANCOILSWATER TERMINAL UNITS PRODUCT RANGE
INTRODUCTION TO THE PRODUCT RANGE ......................................252
UNITS WALL-MOUNTED ......................................KFC-AY ....................255
CEILING/FLOOR .........................................KFC-S(E) ..................257
CASSETTES 600x600 ................................KFC-CI ......................259
CASSETTES ................................................KFC-CIS ....................261
DUCTS .........................................................KFC-PD ....................263
HIGH PRESSURE DUCTS ...........................KFC-PDH ..................265
252
WATER TERMINALUNITS
INTRODUCTION TO THE RANGE OF PRODUCTS
The Cassette 600x600 and Cassette 840x840 units and low profile duct unit are available with 2 and 4 pipes configurations.
The four-duct configurations allow units to work in Cooling mode and in Heating mode simultaneously and separately in the same installation.
Four-duct coils are fitted with two rows to work in Cooling mode, and with one row to work in Heating mode.The Duct and Cassette units include a standard extended drain pan.
The Fancoil Cassette and Duct type units have an optional L-shaped pipework kit for easy installation.
WATER TERMINAL UNITS RANGE FANCOILS
The KAYSUN UK Fancoils product range uses an interface which makes conventional fan coils units compatible with KAYSUN UK electronics. There are two versions, a 2-duct version and a 4-duct version. This interface includes the electronic devices, a connector for wire controllers and sensors. Besides, it makes the Fancoil Ducts and Ceiling/Floor units compatible with direct expansion controls (wall-mounted and cassettes units are already compatible by default).
As an alternative, KAYSUN UK offers a conventional thermostat for the 2-duct and 4-duct systems. It includes two switches (hot/off /cold and 3 speeds), a temperature dial switch and a built-in sensor.
UNITS AVAILABLE FOR 2 AND 4 PIPES SYSTEMS
CONTROL
THERMOSTAT
INTERFACE TO CONTROL
“THE COMFORT OF WATER”
The FANCOIL range completes the existing NEXUS chillers range. The indoor units of this range have different type of models, such as wall-mounted, Ceiling/Floor, cassette 600x600, cassette 840x840, ducts and high static pressure ducts. All they are the perfect solution for any environment.
Go back to General Contents Go back to FANCOILS Index(Index)
253
Design and Install for you
FAN
COIL
SFA
NCO
ILS
425
425
510
1020
425
1700 2000 2380 2550 3060 3740
510 680 850 1020 1250 1360
1250 1360 1600 1700 2000 2380 2550
510
510
680
680
680
850
850
850
1020
1360
WALL-MOUNTED 2 PIPES
CASSETTES 600x600
CEILING/FLOOR 2 PIPES
CASSETTES
Ducts
HIGH STATIC PRESSURE DUCTS 2 PIPES
AIRFLOW (m3/h)
AIRFLOW (m3/h)
AIRFLOW (m3/h)
AIRFLOW (m3/h)
AIRFLOW (m3/h)
AIRFLOW (m3/h)
POWER RANGE
KFC-AY-2T-250
KFC-CI-2T-300
KFC-CIS-2T-600
KFC-PD-2T-300-1KFC-PD-2T-200-1
KFC-PD-4T-300-1KFC-PD-4T-200-1
KFC-PD-2T-400-1
KFC-PDH-2T-1000 KFC-PDH-2T-1400 KFC-PDH-2T-1800 KFC-PDH-2T-2200
KFC-PD-4T-400-1
KFC-PD-2T-600-1
KFC-PD-4T-600-1
KFC-PD-2T-800-1
KFC-PD-4T-800-1
KFC-CIS-4T-600
KFC-CIS-2T-750
KFC-CIS-4T-950
KFC-CIS-2T-1200 KFC-CIS-2T-1500
KFC-CIS-4T-1500
KFC-CI-4T-300
KFC-AY-2T-400 KFC-AY-2T-600
KFC-CI-2T-500
KFC-CI-4T-500
2 PIPES
4 PIPES
2 PIPES
2 PIPES
KFC-SE-2T-250 KFC-SE-2T-300 KFC-SE-2T-400 KFC-SE-2T-500 KFC-SE-2T-800
CONCEALED
4 PIPES
4 PIPES
1530
KFC-S-2T-250-1 KFC-S-2T-300-1 KFC-S-2T-400-1 KFC-S-2T-500-1 KFC-S-2T-900-1
EXPOSED
Go back to General Contents Go back to FANCOILS Index(Index)
255
WATER TERMINALUNITS
WALL-MOUNTED
MODEL KFC-AY-2T-250 KFC-AY-2T-400 KFC-AY-2T-600
Cooling capacity (high)Total kW 2.63 3.28 5
Sensitive kW 1.81 2.26 3.44
Heating capacity kW 3.36 4.37 6.7
Power Input W 24 40 66
Airflow (high / medium / low) m3/h 425/360/320 680/580/510 1020/870/770
Unit dimensions
Height mm 290 290 315
Width mm 915 915 1072
Depth mm 230 230 230
Indoor unit net weight Kg 13 13.3 15.8
Sound pressure (low) dB (A) 20 26 29
Hydraulic connections Ø Inches 3/4 3/4 3/4
Evaporator pressure dropCooling kPa 29.4 43.5 42.5
Heating kPa 27.3 40.8 39.7
Water flow rate m3/h 0.45 0.56 0.86
WALL-MOUNTED
TECHNICAL SPECIFICATIONS2 PIPES
*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb. Heating: water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed. Same water flow as in Heating mode.
Go back to General Contents Go back to FANCOILS Index(Index)
256
Design and Install for you
FAN
COIL
SFA
NCO
ILS
Wall-mounted units with a compact and elegant design. They include a LED display located at the side of the unit that provides it with a modern design by using the most advanced technology in the market.
• The same appearance as the KAYF unit.
• 2 Pipes.
• Standard 3-way on/off valve included.
KID-02 S
*Recommended Kaysun controller.
COMPATIBLE WITH ALL THE KAYSUN CONTROLLERS RANGE+SAME APPEARANCE AS THE KAYF UNIT+
GENERAL CHARACTERISTICS
PRICE CALCULATED BASED ON THE STANDARD OR RECOMMENDED CONTROL
If you want a different control, you should add to the € price for the set the price difference
between the standard or recommended control and the selected control
INDIVIDUAL WIRELESS
INDIVIDUAL WIRED
CENTRALISED BMS AND SOFTWARE
KID-02 SKI-02.3 S
KC-01 S KC-02.1 HKCT-02.1 SR
KCC-64 I PSKCC-16KCCT-64 IKCC-64 WEB
K01-LONK01-KNX
K02-MODBUSKAYNET CONTROL
K01-BACNET K01-WIFI
KAYSUN CONTROLLERS
ELIGE TU CONTROL
CHOOSE YOUR CONTROL
PRICE LIST
MODEL RECOMMENDED CONTROL PRICE
KFC-AY-2T-250 KID-02 S £300
KFC-AY-2T-400 KID-02 S £304
KFC-AY-2T-600 KID-02 S £346
Go back to General Contents Go back to FANCOILS Index(Index)
257
WATER TERMINALUNITS
CEILING/FLOOR
CEILING/FLOOR
MODEL KFC-S-2T-250-1 KFC-S-2T-300-1 KFC-S-2T-400-1 KFC-S-2T-500-1 KFC-S-2T-900-1
Cooling capacity (high)
Total kW 1.87 2.53 3.27 4.85 7.85
Sensitive kW 1.29 1.74 2.25 3.34 5.4
Heating capacity kW 2.53 3.49 4.58 6.98 11.69
Power Input W 45 44 46 49 137
Airflow (high/medium/low) m3/h 425/360/320 510/430/380 680/580/510 850/720/640 1530/1300/1150
Indoor unit dimensions
Height mm 592 592 592 592 592
Width mm 800 1000 1000 1200 1500
Depth mm 220 220 220 220 220
Net weight of indoor unit Kg 22.5 26 26 32.5 39
Sound pressure (low) dB (A) 30 32 34 38 42
Hydraulic connections Ø Inches 3/4 3/4 3/4 3/4 3/4
Pressure loss evaporator
Cooling kPa 10.1 14.2 26.3 20 24.3
Heating kPa 8.8 13.7 24 17.4 21.5
Water flow rate m3/h 0.31 0.44 0.56 0.83 1.35
MODEL KFC-SE-2T-250 KFC-SE-2T-300 KFC-SE-2T-400 KFC-SE-2T-500 KFC-SE-2T-800
Cooling capacity (high)
Total kW 1.87 2.53 3.27 4.85 6.52
Sensitive kW 1.29 1.74 2.25 3.34 4.49
Heating capacity kW 2.53 3.49 4.58 6.98 9.58
Power Input W 45 44 46 49 118
Airflow (high/medium/low) m3/h 425/360/320 510/430/380 680/580/510 850/720/640 1360/1160/1020
Indoor unit dimen-sions
Height mm 545 545 545 545 545
Width mm 550 750 750 950 1250
Depth mm 212 212 212 212 212
Net weight of indoor unit Kg 17 20 20 25 32
Sound pressure (low) dB (A) 28 30 32 36 38
Hydraulic connections Ø Inches 3/4 3/4 3/4 3/4 3/4
Pressure loss evaporator
Cooling kPa 10.1 14.2 26.3 20 21
Heating kPa 8.8 13.7 24 17.4 20.2
Water flow rate m3/h 0.31 0.44 0.56 0.83 1.12
TECHNICAL SPECIFICATIONS2 PIPES
EXPOSED
CONCEALED
*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb.Heating: water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed.Same water flow as in Heating mode.
*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb.Heating: water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed.Same water flow as in Heating mode.
Go back to General Contents Go back to FANCOILS Index(Index)
258
Design and Install for you
FAN
COIL
SFA
NCO
ILS
GENERAL CHARACTERISTICS
This unit is especially designed to save space. Due to its reduced depth, it is the perfect solution that adapts to every type of installation, from wall-mounted to floor standing,
whether totally or partially recessed, adapting perfectly to the aesthetics of the environment.• 2 ducts
COMPATIBLE ACCESSORIES
KV3-FC 3/4 KC-FCS-2T
IT INCLUDES: • 3 BUTTONS
ON/OFF HOT/COLD 3 SPEEDS
• DIRECTIONAL BUTTONS FOR INCREASING/REDUCING TEM-PERATURE
KC-FC-2T KACT-0
COMPATIBLE WITH
COMPATIBLE WITH
ThermostatKC-FC-2T
Thermostat KC-FCS-2T
Interface to control
+
or
K01-FC-2T
*Kaysun thermostat recommended for
exposed units.
*It can be integrated in the body of the exposed CEILING/
FLOOR type unitsCOMPATIBLE WITH AA WIDE RANGE OF CONTROLLERS+HORIZONTAL/VERTICAL INSTALLATION+
INDIVIDUAL WIRED
CENTRALISED BMS AND SOFTWARE
KC-01 S KC-02.1 H KCT-02.1 SR
KCC-64 I PS KCC-16 KCCT-64 I KCC-64 WEB
K01-LON K01-KNX
K02-MODBUS KAYNET CONTROL
K01-BACNET K01-WIFI
KAYSUN CONTROLLERS
ELIGE TU CONTROL
CHOOSE YOUR CONTROL
PRICE LIST
MODEL PRICE
KFC-S-2T-250-1 £197
KFC-S-2T-300-1 £213
KFC-S-2T-400-1 £217
KFC-S-2T-500-1 £285
KFC-S-2T-900-1 £317
KFC-SE-2T-250-1 £166
KFC-SE-2T-300-1 £188
KFC-SE-2T-400-1 £191
KFC-SE-2T-500-1 £253
KFC-SE-2T-800-1 £283
MODEL DESCRIPTION PRICE
KV3-FC 3/4 3-way valve 3/4 £26
KACT-O On/off actuator £22
KC-FC-2T Thermostat 2 Pipes £34
ACCESSORIES
MODEL DESCRIPTION PRICE
KIT TUB FC S(E)-2T-1 Pipework kit for CEILING/FLOOR 2T valve £67
KC-FCS-2TSpecial thermostat (recommended for EXPOSED units)
£49
K02-FC-2T Interface to KAYSUN controller £154
Go back to General Contents Go back to FANCOILS Index(Index)
259
WATER TERMINALUNITS
CASSETTES
MODEL KFC-CI-2T-300 KFC-CI-2T-500
Cooling capacity (high)Total
kW3 4.5
Sensitive 2.06 3.1
Heating capacity kW 4 6
Power Input W 50 95
Airflow (high/medium/low) m3/h 510/440/360 850/730/600
Indoor unit dimensions
Height mm 261 261
Width mm 575 575
Depth mm 575 575
Net weight of indoor unit Kg 17.5 17.5
Panel dimensions
Height mm 50 50
Width mm 647 647
Depth mm 647 647
Panel net weight Kg 3 3
Sound pressure (low) dB (A) 28 34
Hydraulic connections Ø Inches 3/4 3/4
Evaporator pressure drop Cooling kPa 14 16
Heating kPa 14 16
Water flow rate m3/h 0.52 0.77
MODEL KFC-CI-4T-300 KFC-CI-4T-500
Cooling capacity (high)Total
kW2.5 3.5
Sensitive 1.72 2.41
Heating capacity kW 3.7 5.1
Power Input W 50 95
Airflow (high/medium/low) m3/h 510/440/360 850/730/600
Indoor unit dimensions
Height mm 261 261
Width mm 575 575
Depth mm 575 575
Net weight of indoor unit Kg 17.5 17.5
Panel dimensions
Height mm 50 50
Width mm 647 647
Depth mm 647 647
Panel net weight Kg 3 3
Sound pressure (low) dB (A) 28 34
Hydraulic connections Ø Inches 3/4 3/4
Evaporator pressure drop Cooling kPa 22 24
Heating kPa 17 27
Water flow rate m3/h 0.43 0.6
CASSETTES 600x600
TECHNICAL SPECIFICATIONS
2 PIPES
4 PIPES
*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb. Heating: water inlet/outlet temperature 70/60ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed. Same water flow as in Heating mode.
*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb. Heating: water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed. Same water flow as in Heating mode.
Go back to General Contents Go back to FANCOILS Index(Index)
260
Design and Install for you
FAN
COIL
SFA
NCO
ILS
COMPATIBLE ACCESSORIES 2 PIPES
KIT TUB FC CI-2T KV3-FC 3/4 KACT-0
COMPATIBLE ACCESSORIES 4 PIPES
TUB FC CI-4T KIT KV3-FC 1/2KV3-FC 3/4
KACT-0
With its new 360º panel, the Art Flux cassette provides even, fast and far-reaching air-conditioning control, without leaving dead zones. Since the main unit and panel are compact (570mm width and depth), they are lighter and require less space and equipment to be installed. They can be completely integrated into any space, including shallow ceilings, without sticking out. • Condensation pump.• Fresh air supply and air blow towards adjacent rooms.
• Standard extended drainage pan.• Optional pipework kit.• Optional three-way valve.• Optional on/off valve driver• XYE ON interface necessary for centralised/built-in
controllers (optional).
CASSETTE 600x600 2 PIPES CASSETTE 600x600 4 PIPES
KID-02 S
*Kaysun controller
recommended
COMPATIBLE WITH ALL THE KAYSUN CONTROLLERS RANGE+
SAME PANEL AS VRF - ART FLUX 360º UNITS+
GENERAL CHARACTERISTICS
PRICE CALCULATED BASED ON THE STANDARD OR RECOMMENDED CONTROL
If you want a different control, you should add to the € price for the set the price difference
between the standard or recommended control and the selected control
INDIVIDUAL WIRELESS
INDIVIDUAL WIRED
CENTRALISED BMS AND SOFTWARE
KID-02 SKI-02.3 S
KC-01 S KC-02.1 HKCT-02.1 SR
KCC-64 I PSKCC-16KCCT-64 IKCC-64 WEB
K01-LONK01-KNX INTERFACE XYE ON
K02-MODBUSKAYNET CONTROL
K01-BACNET K01-WIFI
KAYSUN CONTROLLERS ELIGE TU CONTROL
CHOOSE YOUR CONTROL
PRICE LIST
MODEL RECOMMENDED CONTROL PRICE
KFC-CI-2T-300 KID-02 S £360
KFC-CI-2T-500 KID-02 S £377
KFC-CI-4T-300 KID-02 S £448
KFC-CI-4T-500 KID-02 S £457
ACCESSORIES FOR 2 PIPES UNITS
MODEL DESCRIPTION PRICE
KIT TUB FC CI-2TPipework kit for Cassette 600x600 units' valve
£32
KV3-FC 3/4 3-way valve 3/4 £26
KACT-O on/off Actuator £22
ACCESSORIES FOR 4 PIPES UNITS
MODEL DESCRIPTION PRICE
KIT TUB FC CI-4TPipework kit for Cassette 600x600 units' valve
£54
KV3-FC 1/2 3-way valve 1/2 (hot water) £26
KV3-FC 3/4 3-way valve 3/4 £26
KACT-O on/off Actuator £22
Go back to General Contents Go back to FANCOILS Index(Index)
261
WATER TERMINALUNITS
CASSETTES
CASSETTESTECHNICAL SPECIFICATIONS
MODEL KFC-CIS-2T-600 KFC-CIS-2T-750 KFC-CIS-2T-1200 KFC-CIS-2T-1500Cooling capacity (high)
TotalkW
5.7 7 10.39 12.9
Sensitive 3.92 4.82 7.15 8.88
Heating capacity kW 9.66 11.55 17.58 17.6
Power Input W 125 130 190 190
Airflow (high/medium/low) m3/h 1000/850/720 1250/1060/900 2000/1700/1440 2550/2170/1840
Indoor unit dimensions
Height mm 230 230 300 300
Width mm 840 840 840 840
Depth mm 840 840 840 840
Net weight of indoor unit Kg 25 25 30.5 35
Panel dimensions
Height mm 45 45 45 45
Width mm 950 950 950 950
Depth mm 950 950 950 950
Net weight (panel) Kg 6 6 6 6
Sound pressure (low) dB (A) 36 37 40 41
Hydraulic connections Ø Inches 3/4 3/4 3/4 3/4
Evaporator pressure drop Cooling kPa 23.8 25.2 44 40
Heating kPa 23.8 25.2 44 40
Water flow rate m3/h 0.98 1.2 1.79 2.22
MODEL KFC-CIS-4T-600 KFC-CIS-4T-950 KFC-CIS-4T-1500Cooling capacity (high)
TotalkW
5.1 6.7 10.58
Sensitive 3.51 4.61 7.28
Heating capacity kW 6.67 8.67 12.62
Power Input W 170 205 234
Airflow (high/medium/low) m3/h 1150/800/690 1720/1200/1030 2100/1470/1260
Indoor unit dimensions
Height mm 300 300 300
Width mm 840 840 840
Depth mm 840 840 840
Net weight of indoor unit Kg 35 35 38
Panel dimensions
Height mm 45 45 45
Width mm 950 950 950
Depth mm 950 950 950
Panel net weight Kg 6 6 6
Sound pressure (low) dB (A) 26 32 36
Hydraulic connections Ø Inches 3/4 3/4 3/4
Evaporator pressure drop Cooling kPa 15 22 38
Heating kPa 37 42 61
Water flow rate m3/h 0.88 1.15 1.82
2 PIPES
4 PIPES
*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb. Heating: water inlet/outlet temperature 70/60ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed. Same water flow as in Heating mode.
*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb. Heating: water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed. Same water flow as in Heating mode.
Go back to General Contents Go back to FANCOILS Index(Index)
262
Design and Install for you
FAN
COIL
SFA
NCO
ILS
CASSETTE 2 PIPES CASSETTE 4 PIPES
KID-02 S
*Kaysun controller
recommended
SAME PANEL AS VRF - ART FLUX 360º UNITS +COMPATIBLE WITH ALL THE KAYSUN CONTROLLERS RANGE +
The 360º panel Art Flux Cassette unit provides an even, fast air-conditioning controller that is far-reaching with no dead zones due to its additional motor, which allows the louvres to swing between 37 and 42º. The unit is so compact and light that it can be integrated into any space, including shallow ceilings, without sticking out.
• Condensation pump.
• Fresh air supply and air blow towards adjacent rooms.• Standard extended drainage pan.• Optional pipework kit.• Optional three-way valve.• Optional ON/OFF valve driver • XYE ON interface necessary for centralised/built-in
controllers (optional).
COMPATIBLE ACCESSORIES 2 PIPES COMPATIBLE ACCESSORIES 4 PIPES
KIT TUB FC CIS-2T KIT TUB FC CIS-4TKV3-FC 3/4 KV3-FC 1/2KV3-FC 3/4
KACT-0 KACT-0
GENERAL CHARACTERISTICS
PRICE CALCULATED BASED ON THE STANDARD OR RECOMMENDED CONTROL
If you want a different control, you should add to the € price for the set the price difference
between the standard or recommended control and the selected controlKAYSUN CONTROLLERS
INDIVIDUAL WIRELESS
INDIVIDUAL WIRED
CENTRALISED BMS AND SOFTWARE
KID-02 SKI-02.3 S
KC-01 S KC-02.1 H KCT-02.1 SR
KCC-64 I PSKCC-16KCCT-64 IKCC-64 WEB
K01-LONK01-KNX INTERFACE XYE ON
K02-MODBUSKAYNET CONTROL
K01-BACNET K01-WIFI
ELIGE TU CONTROL
CHOOSE YOUR CONTROL
ACCESSORIES FOR 2 PIPES UNITS
MODEL DESCRIPTION PRICE
KIT TUB FC CIS-2TPipework kit for valve Cassette unit with 2 pipes
£48
KV3-FC 3/4 3-way valve 3/4 £26
KACT-O on/off Actuator £22
ACCESSORIES FOR 4 PIPES UNITS
MODEL DESCRIPTION PRICE
KIT TUB FC CIS-4TPipework kit for 4-duct Cassette model valves
£64
KV3-FC 1/2 3-way valve 1/2 (hot water) £26
KV3-FC 3/4 3-way valve 3/4 £26
KACT-O on/off Actuator £22PRICE LIST
MODEL RECOMMENDED CONTROL PRICE
KFC-CIS-2T-600 KID-02 S £497
KFC-CIS-2T-750 KID-02 S £497
KFC-CIS-2T-1200 KID-02 S £565
KFC-CIS-2T-1500 KID-02 S £633
KFC-CIS-4T-600 KID-02 S £592
KFC-CIS-4T-950 KID-02 S £609
KFC-CIS-4T-1500 KID-02 S £672
Go back to General Contents Go back to FANCOILS Index(Index)
263
WATER TERMINALUNITS
DUCTS
DUCTS TECHNICAL SPECIFICATIONS
MODELKFC-PD-2T-200-1
KFC-PD-2T-300-1
KFC-PD-2T-400-1
KFC-PD-2T-600-1
KFC-PD-2T-800-1
Cooling capacity (high)Total
kW2.2 3.1 4 5.8 8.2
Sensitive 1.52 2.13 2.96 3.99 5.64
Heating capacity kW 3.5 5.3 6.8 9.8 13.6
Power Input W 49 64 75 114 154
Airflow (high/medium/low) m3/h 340/255/170 510/385/255 680/510/340 1020/765/510 1360/1020/680
Available static pressure Pa 30/50 30/50 30/50 30/50 30/50
Indoor unit dimensions
Height mm 241 241 241 241 241
Width mm 741 841 941 1161 1461
Depth mm 522 522 522 522 522
Net weight of indoor unit Kg 14.6 17 20.2 23 31.9
Sound pressure (low) dB (A) 31 32 33 35 36
Hydraulic connections Ø Inches 3/4 3/4 3/4 3/4 3/4
Evaporator pressure dropCooling kPa 14 26 18 36 39
Heating kPa 10.5 21.8 16.9 31.6 33.8
Water flow rate m3/h 0.38 0.53 0.69 1 1.41
MODELKFC-PD-4T-200-1
KFC-PD-4T-300-1
KFC-PD-4T-400-1
KFC-PD-4T-600-1
KFC-PD-4T-800-1
Cooling capacity (high)Total
kW2 2.7 3.6 5 6.8
Sensitive 1.38 1.86 2.48 3.44 4.68
Heating capacity kW 3 4 5.2 7.2 9.6
Power Input W 49 64 75 114 154
Airflow (high/medium/low) m3/h 340/255/170 510/385/255 680/510/340 1020/765/510 1360/1020/680
Available static pressure Pa 30/50 30/50 30/50 30/50 30/50
Indoor unit dimensions
Height mm 241 241 241 241 241
Width mm 741 841 941 1161 1461
Depth mm 522 522 522 522 522
Net weight of indoor unit Kg 15.1 17.5 20.7 23.5 32.4
Sound pressure (low) dB (A) 31 32 33 35 36
Hydraulic connections Ø Inches 3/4 3/4 3/4 3/4 3/4
Evaporator pressure dropCooling kPa 7.6 14.4 8.2 17.2 18.8
Heating kPa 6.8 12.5 23.5 40.7 20.7
Water flow rate m3/h 0.34 0.46 0.62 0.86 1.17
2 PIPES
4 PIPES
*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb. Heating: water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed. Same water flow as in Heating mode.
*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb. Heating: water inlet/outlet temperature 70/60ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed. Same water flow as in Heating mode.
Go back to General Contents Go back to FANCOILS Index(Index)
264
Design and Install for you
FAN
COIL
SFA
NCO
ILS
The duct type units include a tilted evaporator; it provides a wider exchange area and a compact and reduced height, which facilitates the unit installation in rooms where ceilings are just 241 mm high. Similar characteristics to direct expansion ducts, except that it does not have a condensate pump.
• Plate to support duct during suction/discharge.
• 3 pipe rows
• Removable filter without opening the duct unit case.
• Replaceable outlet panel (rear/lower).
• Fresh air supply.
• Available pressure 30/50 (Pa).
• Standard extended drainage pan on the left-hand side
• Optional left/right pipework kit
• Optional three-way valve.
• Optional on/off valve actuator.
DUCT 2 PIPES DUCT 4 PIPES
COMPATIBLE ACCESSORIES 2 PIPES COMPATIBLE ACCESSORIES 4 PIPES
KIT TUB FC PD-2T-1 KIT TUB FC PD-4T-1K01-FC-2T K01-FC-4TKC-FC-2T KC-FC-4TKV3-FC 3/4 KV3-FC 3/4KACT-0 KACT-0
COMPATIBLE WITH
COMPATIBLE WITH
Thermostat
Interface to control
+
GENERAL CHARACTERISTICS
COMPATIBLE WITH A WIDE RANGE OF CONTROLLER+
INDIVIDUAL WIRED
CENTRALISED BMS AND SOFTWARE
KC-01 S KC-02.1 H KCT-02.1 SR
KCC-64 I PSKCC-16KCCT-64 IKCC-64 WEB
K01-LONK01-KNX
K02-MODBUSKAYNET CONTROL
K01-BACNET K01-WIFI
KAYSUN CONTROLLERS
Compatible con
Compatible con
ELIGE TU CONTROL
CHOOSE YOUR CONTROL
ACCESSORIES FOR 2 PIPES UNITS
MODEL DESCRIPTION PRICE
KIT TUB FC PD-2T-1Plumbing kit for 2-duct low profile pipes valves
£59
KV3-FC 3/4 3-way valve 3/4 £26
KACT-O on/off Actuator £22
K02-FC-2T Interface to KAYSUN control 2 Pipes £154
KC-FC-2T Thermostat 2 pipes £34
ACCESSORIES FOR 4 PIPES UNITS
MODEL DESCRIPTION PRICE
KIT TUB FC PD-4T-1Plumbing kit for 4-duct low profile pipes valves
£104
KV3-FC 3/4 3-way valve 3/4 £26
KACT-O on/off Actuator £22
K02-FC-4T Interface to KAYSUN control 4 Pipes £160
KC-FC-4T Thermostat 4 pipes £34
PRICE LIST
MODEL PRICE KFC-PD-2T-200-1 £157
KFC-PD-2T-300-1 £173
KFC-PD-2T-400-1 £192
KFC-PD-2T-600-1 £221
KFC-PD-2T-800-1 £329
KFC-PD-4T-200-1 £182
KFC-PD-4T-300-1 £204
KFC-PD-4T-400-1 £222
KFC-PD-4T-600-1 £245
KFC-PD-4T-800-1 £351
Go back to General Contents Go back to FANCOILS Index(Index)
265
WATER TERMINALUNITS
CASSETTES
HIGH PRESSURE DUCTS 2 DUCTS
TECHNICAL SPECIFICATIONS
2 PIPES
MODEL KFC-PDH-2T-1000 KFC-PDH-2T-1400 KFC-PDH-2T-1800 KFC-PDH-2T-2200
Cooling capacity (high)Total
kW8.8 12 15.8 19.9
Sensitive 6.06 8.26 10.88 13.7
Heating capacity kW 13.2 17.9 23.8 30
Power Input W 350 350 800 950
Airflow (high/medium/low) m3/h 1700/1530/1380 2380/2120/1860 3060/2750/2450 3740/3360/2990
Available static pressure Pa 70 70 100 100
Indoor unit dimensions
Height mm 400 400 400 400
Width mm 946 946 1290 1290
Depth mm 816 816 809 809
Net weight of indoor unit Kg 52 54 76 76
Sound pressure (low) dB (A) 36 38 46 47
Hydraulic connections Ø Inches 3/4 3/4 3/4 3/4
Evaporator pressure drop kPa 24 36 90 130
kPa 25 34.2 85 121
Water flow rate m3/h 1.51 2.06 2.72 3.42
*Calculation conditions:Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb. Heating: water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed. Information based on 70Pa of available pressure for KFC-PDH-2T-1000 and KFC-PDH-2T-1400. Information based on 100Pa of available pressure for KFC-PDH-2T-1800 and KFC-PDH-2T-2200. Same water flow as in Heating mode.
Go back to General Contents Go back to FANCOILS Index(Index)
266
Design and Install for you
FAN
COIL
SFA
NCO
ILS
These duct units dispose a high static pressure, the indoor unit is able to reach up to 100pa (1800 and 2200 models). This results in flexible ducts that make air-conditioning easier, more accurate and adaptable to every space, even in high ceilings rooms.
• 2 Pipes.
• Removable filter without opening the duct unit case.
• Plate to support duct during suction/discharge.
COMPATIBLE ACCESSORIES
K02-FC-2TKV3-FC 3/4 KACT-0 KC-FC-2T
GENERAL CHARACTERISTICS
INDIVIDUAL WIRED
CENTRALISED BMS AND SOFTWARE
KC-01 S KC-02.1 H KCT-02.1 SR
KCC-64 I PSKCC-16KCCT-64 IKCC-64 WEB
K01-LONK01-KNX
K02-MODBUSKAYNET CONTROL
K01-BACNET K01-WIFI
KAYSUN CONTROLLERS
COMPATIBLE WITH
COMPATIBLE WITHInterface to
control
Thermostat
+
COMPATIBLE WITH A WIDE RANGE OF CONTROLLERS +
1800 - 2200 MODELS 1000 - 1400 MODELS
Compatible with
Compatible with
ELIGE TU CONTROL
CHOOSE YOUR CONTROL
PRICE LIST
MODEL PRICE £
KFC-PDH-2T-1000 £421
KFC-PDH-2T-1400 £451
KFC-PDH-2T-1800 £625
KFC-PDH-2T-2200 £636
ACCESSORIES
MODEL DESCRIPTION PRICE £
KIT TUB FC PDH-2T Pipework kit for valve High Static Pressure Ducts £67
KIT TUB FC PDH-2T-1400 Pipework kit for valve High Static Pressure Ducts (model 1400) £67
KV3-FC 3/4 3-way valve 3/4 £26
KACT-O on/off Actuator £22
K02-FC-2T Interface to KAYSUN control 2 Pipes £154
KC-FC-2T Thermostat 2 pipes £34
Go back to General Contents Go back to FANCOILS Index(Index)
268
Design and Install for you
AQUATIXDOMESTIC HOT WATER RANGE
INTRODUCTION TO THE PRODUCT RANGE ......................................269
UNITSAquantia ................................................Monobloc .........................277
Aquantia ................................................Split ..................................281
Domestic hot water deposits ...............BS, G .................................285
Swimming pools ...................................KSWP ...............................289
Compak .................................................KHP ACS ..........................291
269
DOMESTIC HOT WATERRANGE
INTRODUCTION TO THE RANGE OF PRODUCTS
“THE MOST ECOLOGICAL
INNOVATION FOR YOUR HOME”
DOMESTIC HOT WATER RANGE AQUATIX
The Aquatix range reveals the vital energy of water and how to make the most of the resources in a single space.
Using a heat pump system, hot water with temperatures of up to 70ºC can be produced, putting the best qualities of this natural resource to work to heat the home with domestic hot water and underfloor heating.
The Aquatix heat pump is an alternative to the traditional hot water boiler, and saves a significant amount of energy, offering a broad variety of advantages for the home with maximum energy efficiency.
Aquatix equipment is designed for fast and simple installation, providing the best comfort, most advanced technology and maximum savings.
AQUANTIA
Discover Aquantia, the integrated system that provides heating, cooling and domestic hot water to your home. Enjoy maximum comfort all year round, with the great energy efficiency that characterises this system based on heat pumps.
The reversible heat pump is a system that obtains renewable energy from outside to heat or cool your home. It is the most efficient technology, absorbing more energy from the exterior than what Aquantia consumes.
As well as being more environmentally-friendly and energy efficient than other systems such as boilers, Aquantia can replace all of these systems or work together with them.
++
+
+
IT OFFERS HEATING, COOLING AND DOMESTIC HOT WATER: A YEAR-ROUND SOLUTION
ENERGY EFFICIENT (ECOLOGIC, ECONOMIC)
WIDE RANGE OF OPERATING TEMPERATURES
CAN FUNCTION WITH OTHER SOURCES OF ENERGY, SUCH AS SOLAR ENERGY AND BOILERS
Go back to General Contents Go back to AQUATIX Index(Index)
270
Design and Install for you
AQ
UA
TIX
DO
ME
STI
C H
OT
WA
TER
Heating:• Underfloor heating• Radiators• Fan Coils• Combination of the above
Cooling:• Fan Coils• Underfloor cooling• Combination of the above
Domestic Hot Water:• Accumulation deposits
Aquantia supplies hot and cold water to its underfloor heating, radiators, fan coils and water deposits. In addition to being a totally independent source of energy, it can also work with external sources (solar energy, boilers, etc.).
All components in the compact outdoor unit. A hydraulic system in an indoor unit and a heat pump in an outdoor unit.
THERE ARE TWO INSTALLATION OPTIONS, DEPENDING ON YOUR REQUIREMENTS:
MONOBLOC SPLIT
Go back to General Contents Go back to AQUATIX Index(Index)
271
DOMESTIC HOT WATERRANGE
INTRODUCTION TO THE RANGE OF PRODUCTS
• Touch control
• A wide choice of operating modes
• Priority manager
• Temperature setpoints
• Daily and weekly scheduling
• Option to enquire about working parameters, error codes,
service calls • Different levels of user• Test Run• Follow Me function (temperature sensor built into the control)• Modbus communication
AQUANTIA CONTROL
SOME FUNCTIONS
• Silence mode: Minimum noise levels guaranteed
• Fast domestic hot water mode
• Disinfection mode: Raises temperature to 70ºC
• Air purging
• Pre-heating of the environment
• Dehumidify the ground
• Choose from various operating modes (eco mode, holiday mode) and priority manager
2-way valve
Indoor unit
Zone 1 controlled by thermostat 1
Zone 2 controlled by thermostat 2
Domestic hot water deposit
Outdoor unit
Radiator
T
TTouch control
Thermostat 1
Thermostat 2
Under�oor heating
3-way valveM
M
Zone 1
Zone 2
Go back to General Contents Go back to AQUATIX Index(Index)
272
Design and Install for you
AQ
UA
TIX
DO
ME
STI
C H
OT
WA
TER
Brushless DC fan motor BLDC fan motor with stepless control helps to meet heating and cooling demands with low noise fan, super quiet operation, as well low power consumption.
The newly designed twin rotary DC inverter compressor with permanent magnet brings low working sound, wide working frequency and precession control. The upgraded DC motor power system of inverter model forms a full DC frequency conversion system and dramatically reduces power consumption by more than 30%.
DC inverter compressor
Fin-coil heat exchanger9.5 inner-threaded copper pipes optimize heat exchange eciency. Window ns enlarge the heat-exchanging area and decrease the air resistance. Blue coating increases the resistance against corrosive agents, enhance durability.
Doublerotary
Singlerotary
Double rotary compressor
Highly e�cient DC motor
- Resdesigned core motor
- High-density neodymium magnet
- Concentrated stator
- Wider operating frequency range
Minimal vibration
- Twin eccentric cams
- 2 balance weights
Highly stable moving parts
- Optimal material matching rollers and vanes
- Optimize compressor drive technolog
- Highly robust bearings
- Compact structure
Hydronic module Hydronic module with integrated DC water pump (monobloc) or separate DC water pump (bibloc)
Heat capacity of up to 80% at -7ºC, thanks to the size of the exchanger and compressor.
Support resistance It has support electric resistance for extreme outdoor temperatures
EASY INSTALLATION, MINIMAL MAINTENANCE
• Compact structure. The hydronic part can be installed indoors or outdoors.
• Easily connected to the pipe system of the house.
• Rapid access to the components of the system for inspection and maintenance
SMART, ADAPTABLE SYSTEM
• Select a work curve. Depending on the desired temperature, the system will automatically adapt when the temperature outside
changes.
WIDE RANGE OF OPERATING TEMPERATURES
60°C
40°C
Domestic hot water
25°C
5°C
Cooling
60°C
25°C
Heating
10°C
5°C
20°C
30°C
40°C
50°C
60°C
70°C
Output water temperature
46°C
-5°C
Cooling
35°C
-20°C
Heating 43°C
-20°C
Domestic hot water
-20°C
-10°C
0°C
10°C
20°C
30°C
40°C
50°C
60°C
Outdoor ambient temperature
Go back to General Contents Go back to AQUATIX Index(Index)
273
DOMESTIC HOT WATERRANGE
INTRODUCTION TO THE RANGE OF PRODUCTS
CHARACTERISTICS
DC INVERTER
The traditional motors used in heat pumping systems waste energy, as they always work
at full load.
The technology used in the KAYSUN UK DC Inverter reduces energy consumption by up to
30%, since it adapts energy consumption to the actual load of the system.
WATER AT CONSTANT TEMPERATURE
The rotation speed of the compressor is controlled with great precision and according to
demand using DC Inverter technology. The temperature setpoint for the water remains
stable, providing the user with greater comfort.
FEWER STOPS AND STARTS
The technology of the inverter reduces the frequency of stop-start cycles. This extends
the life of components and minimises noise.
QUIET
Most of the time it is in operation, the energy requirements of the home are less than full
capacity.
As well as a silence mode, due to the adjustable frequency of the compressor the
equipment for the most part operates at less than full capacity, reducing noise levels.
BOTH AQUANTIA (MONOBLOC AND SPLIT) HAVE AN ERP ENERGY EFFICIENCY RATING OF A++
Go back to General Contents Go back to AQUATIX Index(Index)
274
Design and Install for you
AQ
UA
TIX
DO
ME
STI
C H
OT
WA
TER
AQUANTIA MONOBLOC
AQUANTIA SPLIT
POWER RANGE
4 5 6 7 8 12 14 16Heating capacity (kW)
KHP-MO 7 DVN KHP-MO 14 DVN
KHP-MO 14 DTN
KHP-MO 5 DVN KHP-MO 12 DVN
KHP-MO 12 DTN
KHP-MO 16 DVN
KHP-MO 16 DTN
SINGLE-PHASE
THREE-PHASE
4 5 6 7 8 12 14 16Heating capacity (kW)
KHP-BI 6 DVN KHP-BI 14 DVN
KHP-BI 14 DTN
KHP-BI 4 DVN KHP-BI 12 DVNKHP-BI 8 DVN
KHP-BI 12 DTN
KHP-BI 16 DVN
KHP-BI 16 DTN
SINGLE-PHASE
THREE-PHASE
SWIMMING POOLS
Thanks to these units, users will be able to heat, cool their swimming pool water and enjoy with their families while they swim without having to worry about water temperature.
KAYSUN UK introduces four units of 6, 8, 12 and 14 kW that can adapt to the needs of any standard household swimming pool. The KSWPs are small and compact, so can be installed without being seen.
Thanks to the built-in titanium pipe in pipe exchanger, these units can work with all kinds of water without considering its source or treatment (chlorine, salt electrolysis, bromine, ozone, among others). If compared to other materials, it provides the exchanger with longer durability.
Go back to General Contents Go back to AQUATIX Index(Index)
275
DOMESTIC HOT WATERRANGE
INTRODUCTION TO THE RANGE OF PRODUCTS
COMPAK
COMPAK KHP
This compact unit, fitted with evaporator, condenser and built-in tank, is an optional solution to be considered for producing domestic hot water or underfloor heating. This option is easy to integrate into many spaces because it eliminates the need for many units, as everything is built into the same unit.
This unit's condenser is built around the water tank, keeping the refrigerant and domestic hot water from coming into direct contact.
COMPAK KHP 35 300 ACS 1
The new 3 kW COMPAK KHP unit with vitrified enamel, which allows water to be discharged at temperatures close to 70ºC.
This compact unit, equipped with a centrifugal fan and a static pressure of 25 Pa, allows to direct the air through a duct of up to 10 metres in length.
COMPAK KHP 35 300 ACS 1
water
water tank
liquid tank
compressorfan / evaporator
Thermostatic expansion valve
magnesium anode
condenser
auxiliary heater
AIR INLETAIR INLET
COMPAK KHP 15 190 ACS 1
The KAYSUN UK COMPAK KHP 15 190 ACS1 is an ideal option for domestic use. With a storage capacity of 190 litres and a power input of 500W, it is an interesting option for producing domestic hot water.
LITRES 250 300 350200150
COMPAK KHP 15 190 ACS 1
COMPAK KHP 35 ACS 1
Go back to General Contents Go back to AQUATIX Index(Index)
277
DOMESTIC HOT WATERRANGE
INTEGRATED SYSTEM
AQUANTIA MONOBLOCTECHNICAL SPECIFICATIONS
MODEL KHP-MO 5 DVN KHP-MO 7 DVNPower Supply V/ph/Hz 220-240/1/50 220-240/1/50
Heating capacity1kW 4.64 6.55
kCal/h 3990 5632
Heating input1 kW 0.97 1.45
COP1 W/W 4.79 4.52
Heating capacity2kW 4.72 6.72
kCal/h 4058 5778
Heating input2 kW 1.44 2.01
COP2 W/W 3.29 3.35
Cooling capacity3kW 4.77 6.63
kCal/h 4101 5701
Cooling input3 kW 1.01 1.46
EER3 W/W 4.72 4.53
Cooling capacity4kW 4.65 6.69
kCal/h 3998 5752
Cooling input4 kW 1.56 2.48
EER4 W/W 2.98 2.70
Energy classWater outlet 35ºC A++ A++
Water outlet 55ºC A+ A+
Compressor type Double Rotary DC Inverter
Number of outdoor ventilators 1 1
Outdoor airflow m3/h 3050 3050
Exchanger type (water) Plates
Loss of load from water pump m 6 6
Refrigerant oil type R-410 R-410
Volume of preload Kg 2.4 2.4
Volume of expansion tank L 2 2
Regulation Electronic expansion valve
Standard backup resistor kW - -
Optional backup resistor kW 3 3
Heating sound pressure level5 dB (A) 62 62
Cooling sound pressure level5 dB (A) 63 63
DimensionsHeight mm 945 945
Width mm 1210 1210
Depth mm 402 402
Weight Kg 99 99
Pipe connections diameter Inches 1" female BSP 1" female BSP
Safety valve Mpa 0.3 0.3
Total water volume L 2 2
Outdoor ambient temperatureHeating ºC -20~35
Cooling ºC -5~46
DHW ºC -20~43
Output water temperatureHeating ºC 25~60
Cooling ºC 5~25
DHW ºC 40~60
Rated capacities based on the following conditions:1 Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 30/35ºC2 Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 40/45ºC3 Air in evaporator at 35ºC, water in input/output evaporator 23/18ºC4 Air in condenser at 35ºC, water in input/output evaporator 12/7ºC5 At 1 metre without obstacles, side of ventilator (sound pressure)
Go back to General Contents Go back to AQUATIX Index(Index)
278
Design and Install for you
AQ
UA
TIX
DO
ME
STI
C H
OT
WA
TER
KHP-MO 12 DVN KHP-MO 12 DTN KHP-MO 14 DVN220-240/1/50 380-415/3/50 220-240/1/50
12.13 12.33 14.75
10430 10602 12683
2.63 2.72 3.42
4.61 4.54 4.31
12.57 11.97 14.06
10808 10292 12089
3.86 3.68 4.45
3.26 3.25 3.16
12.23 12.68 14.17
10516 109.03 12184
2.60 2.72 3.18
4.70 4.67 4.46
12.21 12.27 12.99
10499 10550 11169
4.14 4.22 4.50
2.95 2.91 2.89
A++ A++ A++
A+ A+ A++
Double Rotary DC Inverter
2 2 2
6150 7000 6150
Plates
7.5 7.5 7.5
R-410 R-410 R-410
3.6 3.6 3.6
5 5 5
Electronic expansion valve
3 4.5 3
- - -
67 67 71
66 66 70
1414 1408 1414
1405 1397 1405
405 400 405
162 174 162
1-1/4" female BSP 1-1/4" female BSP 1-1/4" female BSP
0.3 0.3 0.3
5.5 5.5 5.5
-20~35
-5~46
-20~43
25~60
5~25
40~60
Go back to General Contents Go back to AQUATIX Index(Index)
279
DOMESTIC HOT WATERRANGE
INTEGRATED SYSTEM
AQUANTIA MONOBLOC
TECHNICAL SPECIFICATIONS
MODEL KHP-MO 14 DTN KHP-MO 16 DVN KHP-MO 16 DTNPower Supply V/ph/Hz 380-415/3/50 220-240/1/50 380-415/3/50
Heating capacity1kW 14.08 16.38 16.3
kCal/h 12107 14084 14015
Heating input1 kW 3.24 4.02 3.88
COP1 W/W 4.35 4.08 4.19
Heating capacity2kW 14.09 16.13 16.08
kCal/h 12115 13869 13826
Heating input2 kW 4.43 5.22 5.24
COP2 W/W 3.18 3.09 3.07
Cooling capacity3kW 14.05 14.93 15.13
kCal/h 12081 12837 13009
Cooling input3 kW 3.24 3.64 3.75
EER3 W/W 4.34 4.10 4.03
Cooling capacity4kW 13.83 13.75 15.27
kCal/h 11892 11823 13130
Cooling input4 kW 5.12 5.13 6.42
EER4 W/W 2.70 2.68 2.38
Energy classWater outlet 35ºC A++ A++ A++
Water outlet 55ºC A++ A+ A++
Compressor type Double Rotary DC Inverter
Number of outdoor ventilators 2 2 2
Outdoor airflow m3/h 7000 6150 7000
Exchanger type (water) Plates
Loss of load from water pump m 7.5 7.5 7.5
Refrigerant oil type R-410 R-410 R-410
Volume of preload Kg 3.6 3.6 3.6
Volume of expansion tank L 5 5 5
Regulation Electronic expansion valve
Standard backup resistor kW 4.5 3 4.5
Optional backup resistor kW - - -
Heating sound pressure level5 dB (A) 71 72 72
Cooling sound pressure level5 dB (A) 70 71 71
DimensionsHeight mm 1408 1414 1408
Width mm 1397 1405 1397
Depth mm 400 405 400
Weight Kg 174 162 174
Pipe connections diameter Inches 1-1/4" female BSP 1-1/4" female BSP 1-1/4" female BSP
Safety valve Mpa 0.3 0.3 0.3
Total water volume L 5.5 5.5 5.5
Outdoor ambient temperatureHeating ºC -20~35
Cooling ºC -5~46
DHW ºC -20~43
Output water temperatureHeating ºC 25~60
Cooling ºC 5~25
DHW ºC 40~60
Rated capacities based on the following conditions:1 Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 30/35ºC2 Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 40/45ºC3 Air in evaporator at 35ºC, water in input/output evaporator 23/18ºC4 Air in condenser at 35ºC, water in input/output evaporator 12/7ºC5 At 1 metre without obstacles, side of ventilator (sound pressure)
Go back to General Contents Go back to AQUATIX Index(Index)
280
Design and Install for you
AQ
UA
TIX
DO
ME
STI
C H
OT
WA
TER
An integrated system that provides heating, cooling and domestic hot water to your home. It can generate energy totally independently using its heat pump, or draw on other sources (solar energy, boilers, etc.) already installed.
• DC ventilator and compressor.
• Heating, cooling and domestic hot water from a single system.
• It can operate on its own or draw on other energy sources already installed.
• All components in a compact outdoor unit.
GENERAL CHARACTERISTICS HEATING
COOLING
DOMESTIC HOT WATER
TOUCH CONTROL
SMART, ADAPTABLE SYSTEM
EASY INSTALLATION, MINIMAL MAINTENANCE
WIDE RANGE OF OPERATING TEMPERATURES
UNDERFLOOR HEATING+
FANCOILS+
ACCUMULATION DEPOSITS+
RADIATORS+
COLD FLOOR+
FANCOILS+
COMBINATION OF THE ABOVE+
COMBINATION OF THE ABOVE+
AQUANTIA MONOBLOC
PRICE LIST
MODEL POWER SUPPLY CAPACITY HEATING (KW) CONTROL PRICE
KHP-MO 5 DVN 220/1/50 5 KCTAQ-01 £2,791
KHP-MO 7 DVN 220/1/50 7 KCTAQ-01 £3,067
KHP-MO 12 DVN 220/1/50 12 KCTAQ-01 £5,101
KHP-MO 12 DTN 380/3/50 12 KCTAQ-01 £5,186
KHP-MO 14 DVN 220/1/50 14 KCTAQ-01 £5,420
KHP-MO 14 DTN 380/3/50 14 KCTAQ-01 £5,531
KHP-MO 16 DVN 220/1/50 16 KCTAQ-01 £5,716
KHP-MO 16 DTN 380/3/50 16 KCTAQ-01 £5,901
ACCESSORY* PRICE
KIT R 8 VN optional backup resistor kit £422
*For KHP-MO 5 DVN and KHP-MO 7 DVN
Go back to General Contents Go back to AQUATIX Index(Index)
281
DOMESTIC HOT WATERRANGE
INTEGRATED SYSTEM
AQUANTIA SPLIT OUTDOOR UNIT
TECHNICAL SPECIFICATIONS
MODEL KHP-BI 4 DVN KHP-BI 6 DVN KHP-BI 8 DVNPower Supply V/ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50
Heating capacity1kW 4.10 6.10 8.00
kCal/h 3525 5245 6879
Heating input1 kW 0.82 1.29 1.73
COP1 W/W 5.00 4.73 4.62
Heating capacity2kW 4.01 5.96 7.34
kCal/h 3448 5125 6311
Heating input2 kW 1.13 1.68 2.13
COP2 W/W 3.55 3.55 3.45
Cooling capacity3kW 4.10 6.10 8.00
kCal/h 3525 5245 6879
Cooling input3 kW 0.79 1.31 1.78
EER3 W/W 5.19 4.66 4.49
Cooling capacity4kW 4.12 6.15 6.44
kCal/h 3543 5288 5537
Cooling input4 kW 1.30 2.08 2.24
EER4 W/W 3.17 2.96 2.88
Energy classWater outlet 35ºC A++ A++ A++
Water outlet 55ºC A+ A+ A+
Compressor type Double Rotary DC Inverter
Number of outdoor ventilators 1 1 1
Outdoor airflow m3/h 3180 3180 5120
Refrigerant oil type R-410 R-410 R-410
Volume of preload Kg 2.5 2.8 3.9
Heating sound pressure level5 dB (A) 62 62 64
Cooling sound pressure level5 dB (A) 62 62 64
DimensionsHeight mm 860 860 965
Width mm 960 960 1075
Depth mm 380 380 395
Weight Kg 60 76 99
Pipe connections
Liquid pipe diameter mm ø9.5 ø9.5 ø9.5
Gas pipe diameter mm ø15.9 ø15.9 ø15.9
Pipe length (min./max.)
m 2/20 2/20 2/30
Height difference, upper outdoor unit
m 10 10 20
Height difference, lower outdoor unit
m 8 8 15
Outdoor ambient temperature
Heating ºC -20~35
Cooling ºC -5~46
DHW ºC -20~43
Rated capacities based on the following conditions:1 Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 30/35ºC2 Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 40/45ºC3 Air in evaporator at 35ºC, water in input/output evaporator 23/18ºC4 Air in condenser at 35ºC, water in input/output evaporator 12/7ºC5 At 1 metre without obstacles, side of ventilator (sound pressure)
Go back to General Contents Go back to AQUATIX Index(Index)
282
Design and Install for you
AQ
UA
TIX
DO
ME
STI
C H
OT
WA
TER
KHP-BI 12 DVN KHP-BI 12 DTN KHP-BI 14 DVN KHP-BI 14 DTN KHP-BI 16 DVN KHP-BI 16 DTN220-240/1/50 380-415/3/50 220-240/1/50 380-415/3/50 220-240/1/50 380-415/3/50
12.10 12.10 14.00 14.00 15.50 15.50
10404 10404 12038 12038 13328 13328
2.74 2.68 3.39 3.26 3.82 3.79
4.42 4.51 4.13 4.29 4.06 4.09
11.85 11.97 14.05 13.93 16.05 15.48
10189 10292 12081 119.78 13801 13310
3.48 3.50 4.41 4.21 5.03 4.87
3.41 3.42 3.19 3.31 3.19 3.18
11.80 12.10 13.00 13.00 14.00 14.00
10146 10404 11178 11178 12038 12038
2.65 2.82 2.65 3.21 3.63 3.68
4.45 4.29 4.02 4.05 3.87 3.8
11.02 11.70 12.49 12.53 12.85 12.91
9475 10060 10739 10774 11049 11101
4.17 4.65 5.07 5.21 5.39 5.52
2.64 2.52 2.46 2.40 2.38 2.34
A++ A++ A++ A++ A++ A++
A+ A+ A+ A+ A+ A+
Double Rotary DC Inverter
2 2 2 2 2 2
6500 6500 6500 6500 6500 6500
R-410 R-410 R-410 R-410 R-410 R-410
3.9 4.2 3.9 4.2 3.9 4.2
66 66 69 69 71 71
66 66 69 69 71 71
1327 1327 1327 1327 1327 1327
900 900 900 900 900 900
400 400 400 400 400 400
99 115 99 115 99 115
ø9.5 ø9.5 ø9.5 ø9.5 ø9.5 ø9.5
ø15.9 ø15.9 ø15.9 ø15.9 ø15.9 ø15.9
2/50 2/50 2/50 2/50 2/50 2/50
30 30 30 30 30 30
25 25 25 25 25 25
-20~35
-5~46
-20~43
Go back to General Contents Go back to AQUATIX Index(Index)
283
DOMESTIC HOT WATERRANGE
INTEGRATED SYSTEM
TECHNICAL SPECIFICATIONS
MODEL KIT KHP BI 8 VN KIT KHP BI 16 VN KIT KHP BI 16 TNPower Supply V/ph/Hz 220-240/1/50 220-240/1/50 380-415/3/50
Water outlet temperature ranges
Heating (low) ºC 25~55, default 35
Heating (high) ºC 35~60, default 45
Cooling (low) ºC 7~25, default 7
Cooling (high) ºC 18~25, default 18
DHW ºC 40~60, default 45
Dimensions
Height mm 865
Width mm 400
Depth mm 427
Weight Kg 43 54 54
Pipe connections diameter mm DN25
Safety valve Mpa 0.3 0.3 0.3
Total water volume L 4.7 5 5
Volume of expansion tank L 3 3 3
Exchanger type Plates
Loss of load from water pump m 6 7.5 7.5
Refrigerant circuit diameter (liquid) mm ø9.5 ø9.5 ø9.5
Refrigerant circuit diameter (gas) mm ø15.9 ø15.9 ø15.9
Standard backup resistor kW 3.0 3.0 4.5
AQUANTIA SPLIT INDOOR UNIT
Go back to General Contents Go back to AQUATIX Index(Index)
284
Design and Install for you
AQ
UA
TIX
DO
ME
STI
C H
OT
WA
TER
An integrated system that provides heating, cooling and domestic hot water to your home. It can generate energy totally independently using its heat pump, or draw on other sources (solar energy, boilers, etc.) already installed.
• DC ventilator and compressor.• Heating, cooling and domestic hot water from a single system.• It can operate on its own or draw on other energy sources
already installed.
A hydraulic system in an indoor unit and a heat pump in an outdoor unit.
GENERAL CHARACTERISTICS HEATING
COOLING
DOMESTIC HOT WATER
TOUCH CONTROL
SMART, ADAPTABLE SYSTEM
EASY INSTALLATION, MINIMAL MAINTENANCE
WIDE RANGE OF OPERATING TEMPERATURES
UNDERFLOOR HEATING+
FANCOILS+
ACCUMULATION DEPOSITS+
RADIATORS+
COLD FLOOR+
FANCOILS+
+
COMBINATION OF THE ABOVE
COMBINATION OF THE ABOVE
+
AQUANTIA SPLIT
PRICE LIST
MODEL POWER SUPPLY CAPACITY HEATING (KW) CONTROL UNIT
OUTDOOR PRICE
KHP-BI 4 DVN 220/1/50 4 KCTAQ-01 KIT KHP BI 8 VN £1,149
KHP-BI 6 DVN 220/1/50 6 KCTAQ-01 KIT KHP BI 8 VN £1,203
KHP-BI 8 DVN 220/1/50 8 KCTAQ-01 KIT KHP BI 8 VN £1,558
KHP-BI 12 DVN 220/1/50 12 KCTAQ-01 KIT KHP BI 16 VN £2,291
KHP-BI 12 DTN 380/3/50 12 KCTAQ-01 KIT KHP BI 16 TN £2,396
KHP-BI 14 DVN 220/1/50 14 KCTAQ-01 KIT KHP BI 16 VN £2,790
KHP-BI 14 DTN 380/3/50 14 KCTAQ-01 KIT KHP BI 16 TN £2,889
KHP-BI 16 DVN 220/1/50 16 KCTAQ-01 KIT KHP BI 16 VN £3,110
KHP-BI 16 DTN 380/3/50 16 KCTAQ-01 KIT KHP BI 16 TN £3,332
Go back to General Contents Go back to AQUATIX Index(Index)
285
DOMESTIC HOT WATERRANGE
DEPOSITS FOR DOMESTIC HOT WATER
DEPOSITS FOR DOMESTIC HOT WATER
TECHNICAL SPECIFICATIONS
MODEL BSX160 BSX200 BSX300Capacity L. 160 200 300
Heat Exchanger type Heat coil Heat coil Heat coil
Dimensions
Height mm 1124 1315 1209
Diameter mm Ø 590 Ø 590 Ø 700
Floor including front cover mm 630 630 740
Net weight Kg 104 123 136
Upper heat coil entrance diameter Inches - - -
Upper heat coil exit diameter Inches - - -
Area of upper heat coil m2 - - -
Lower heat coil entrance diameter Inches 1” 1” 1”
Lower heat coil exit diameter Inches 1” 1” 1”
Area of lower heat coil m2 1.48 1.70 2.20
Cold water inlet Inches 3/4” 3/4” 1”
Heat water outlet Inches 3/4” 3/4” 1”
Circulation Inches 3/4” 3/4” 1”
Cleaning cap mm 280 280 280
Tank protective cap material Coat of enamel
Interior cover Steel
Exterior cover Galvanized steel with electrostatic coating with powdered paint.
Casing colour White
Plugs and exterior cap material Black coloured plastic
Insulating material and thickness mm Injected polyurethane foam, 50 mm
Input of sensors for the automatic control of the unit Ø / depth (mm) 3 units, Ø13 x 100
Operating pressure bar 10 10 10
Test pressure bar 13 13 13
Temperature indicator Analogue thermometer
Anti-corrosive protection Magnesium anode rod and tester
Go back to General Contents Go back to AQUATIX Index(Index)
286
Design and Install for you
AQ
UA
TIX
DO
ME
STI
C H
OT
WA
TER
MODEL BS500 KAYSUN G-751Capacity L. 500 750
Heat Exchanger type Heat coil Heat coil
Dimensions
Height mm 1800 2010
Diameter mm Ø 750 Ø 940
Floor including front cover mm 790 1000
Net weight Kg 192 285
Upper heat coil entrance diameter Inches - -
Upper heat coil exit diameter Inches - -
Area of upper heat coil m2 - -
Lower heat coil entrance diameter Inches 1 1/4" 1 1/4"
Lower heat coil exit diameter Inches 1 1/4" 1 1/4"
Area of lower heat coil m2 2.45 4.87
Cold water inlet Inches 1" 1 1/4"
Heat water outlet Inches 1" 1 1/4"
Circulation Inches 1" 1 1/4"
Cleaning cap mm 280 DN200
Tank protective cap material Coat of enamel Low carbon steel
Interior cover Steel Double coat of vitrified Enamel
Exterior cover Galvanised steel with electrostatic coating with powdered paint Soft PVC coating
Casing colour White Yellow
Plugs and exterior cap material Black coloured plastic
Insulating material and thickness mm Injected polyurethane foam, 50 mm
Input of sensors for the automatic control of the unit Ø / depth (mm) 3 units, Ø13 x 100 1 units 1/2”
Operating pressure bar 10 9
Test pressure bar 13 18
Temperature indicator Analogue thermometer
Anti-corrosive protection Magnesium anode rod and tester
Go back to General Contents Go back to AQUATIX Index(Index)
287
DOMESTIC HOT WATERRANGE
DEPOSITS FOR DOMESTIC HOT WATER
DEPOSITS FOR DOMESTIC HOT WATER
TECHNICAL SPECIFICATIONS
MODEL KAYSUN G-1001 KAYSUN G-1002 KAYSUN G-1501 KAYSUN G-2001Capacity L. 1000 1000 1500 2000
Heat Exchanger type Heat coil Double heat coil Heat coil Heat coil
Dimensions
Height mm 2015 2015 2050 2060
Diameter mm Ø 1000 Ø 1000 Ø 1200 Ø 1350
Floor including front cover mm 1065 1065 1300 1450
Net weight Kg 340 350 520 570
Upper heat coil entrance diameter Inches - 1 1/4" - -
Upper heat coil exit diameter Inches - 1 1/4" - -
Area of upper heat coil m2 - 1.8 - -
Lower heat coil entrance diameter Inches 1 1/4" 1 1/4" 1 1/4" 1 1/4"
Lower heat coil exit diameter Inches 1 1/4" 1 1/4" 1 1/4" 1 1/4"
Area of lower heat coil m2 5.06 3.86 6.83 7.52
Cold water inlet Inches 1 1/4" 1 1/4" 1 1/4" 1 1/4"
Heat water outlet Inches 1 1/4" 1 1/4" 1 1/4" 1 1/4"
Circulation Inches 1 1/4" 1 1/4" 1 1/4" 1 1/4"
Cleaning cap mm DN200 DN200 DN400 DN400
Tank protective cap material Low carbon steel
Interior cover Double coat of vitrified Enamel
Exterior cover Soft PVC coating
Casing colour Yellow
Plugs and exterior cap material Black coloured plastic
Insulating material and thickness mm Insulating foam, 75 mm
Input of sensors for the automatic control of the unit Inches
1 unit 1/2”
2 units 1/2" each
1 unit 1/2”
2 units 1/2" each
Operating pressure bar 9 9 9 9
Test pressure bar 18 18 18 18
Temperature indicator Analogue thermometer
Anti-corrosive protection Magnesium anode rod and tester
Go back to General Contents Go back to AQUATIX Index(Index)
288
Design and Install for you
AQ
UA
TIX
DO
ME
STI
C H
OT
WA
TER
The Aquatix range is fitted with tanks for domestic hot water and underfloor heating. These tanks are an ideal complement for Aquantia systems.
When there are two heat coils available, the upper heat coil is connected to a domestic hot water heat pump, while the other heat coil can be used for hot water from a solar thermal system or a conventional boiler.
• 1-2 heat coils available inside the unit.
• Optional 2kW backup resistor with thermostat.
• Magnesium protection anode to avoid internal corrosion of the tank. Malfunction test included.
• Analogue thermometer to know the temperature of the upper side of the tank.
DEPOSIT G (1 HEAT COIL)BS AND BSX DEPOSIT DEPOSIT G (2 HEAT COILS)
* Connected to upper heat coil
GENERAL CHARACTERISTICS
PRICE LIST
MODEL 1 HEAT COIL CAPACITY IN LITRES PRICE
BSX160 160 £757
BSX200 200 £813
BSX300 300 £973
BS500 500 £1,034
G-751 750 £1,753
G-1001 1000 £2,088
G-1501 1500 £2,781
G-2001 2000 £3,012
MODEL 2 HEAT COILS CAPACITY IN LITRES PRICE
G-1002 1000 £2,347
ACCESSORY PRICE
RT1, resistor of 2 kW with thermostat for models G- £46
RT2, resistor of 2 kW with thermostat for models B- £52
Go back to General Contents Go back to AQUATIX Index(Index)
289
DOMESTIC HOT WATERRANGE
UNITS FOR SWIMMING POOLS
MODEL KSWP-60HN KSWP-80 HN KSWP-120 HN KSWP-140 HNPower Supply V/ f/ Hz 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50
Outdoortemperature
Heating mode ºC -7 ~ 38 -7 ~ 38 -7 ~ 38 -7 ~ 38
Cooling mode ºC 15 ~ 43 15 ~ 43 15 ~ 43 15 ~ 43
Water outlettemperature
Heating mode ºC Defect 28, 20 ~ 35 Defect 28, 20 ~ 35 Defect 28, 20 ~ 35 Defect 28, 20 ~ 35
Cooling mode ºC Defect 28, 10 ~ 30 Defect 28, 10 ~ 30 Defect 28, 10 ~ 30 Defect 28, 10 ~ 30
Heating mode
Capacity kW 6 8 11.7 13.6
Input power kW 1.15 1.16 2.35 2.55
Cop - 5.22 5.27 4.98 5.33
Cooling mode
Capacity kW 4 5.8 8.25 10.35
Input power kW 1.25 1.5 2.5 2.9
EER - 3.2 3.87 3.3 3.57
Sound Pressure Level dB (A) 58 58 58 58
Heat exchanger type Titanium piped exchanger
Volume of R410a refrigerant Kg 1 1.25 1.6 1.85
Maximum volume swimming pool m3 Conduct prior thermal study
Water flow rate m3/h 2.6 3.5 5 5.8
Water flow rate (max./min.) m3/h 20/0.8 20/0.8 20/1.5 20/1.5
Dimensions
Width mm 1015 1015 1050 1050
Height mm 705 705 855 855
Depth mm 385 385 315 315
Net weight Kg 58.5 66 75 75
Hydraulicconnections
Input mm (inch) PVC 50 (2”) PVC 50 (2”) PVC 50 (2”) PVC 50 (2”)
Output Input PVC 50 (2”) PVC 50 (2”) PVC 50 (2”) PVC 50 (2”)
Drain mm (inch) PVC 25 (1”) PVC 25 (1”) PVC 25 (1”) PVC 25 (1”)
Max./min. pressure Water MPa 0.4/0.15 0.4/0.15 0.4/0.15 0.4/0.15
Heat exchanger pressure drop kPa 12 12 15 18
SWIMMING POOLS
TECHNICAL SPECIFICATIONS
Calculation conditions: Heating: outdoor temperature 24/19ºC (DB/WB), water inlet temperature 27ºC, water outlet temperature 29ºC. Cooling: outdoor temperature 35/24ºC (DB/WB), water inlet temperature 27ºC. Defined water flow.
PRICE LIST
MODEL PRICE
KSWP-60HN £1,016
KSWP-80HN £1,078
KSWP-120HN £1,262
KSWP-140HN £1,355
Go back to General Contents Go back to AQUATIX Index(Index)
290
Design and Install for you
AQ
UA
TIX
DO
ME
STI
C H
OT
WA
TER
KAYSUN UK has added new household units for swimming pools to the Aquatix range. This new family consists of four units of 6, 8, 12 and 14kW.
Their wide working range, from -7ºC to 43ºC, allows them working day, night, and under any weather condition, which turns them into highly versatile products.
These units can be used to heat or cool swimming pool water to provide users with greater comfort.These units have a titanium exchanger that provides them with longer durability and allows them working without considering its source or treatment of the water (the treatment of chlorine, salt electrolysis, bromine, ozone, among others).
The slim design and reduced maintenance space of these new units allow users to install them anywhere at your home without inconveniences.
They are fitted with a simple controller that helps users to control the unit easily and accurately. The controller operating range is 1 metre.
GENERAL CHARACTERISTICS
The following diagram shows a typical installation of one of these units with all the necessary elements to carry out the hydraulic connection to the swimming pool.
Go back to General Contents Go back to AQUATIX Index(Index)
291
DOMESTIC HOT WATERRANGE
ACCUMULATORS
MODEL COMPAK KHP 15 190 ACS 1 COMPAK KHP 35 300 ACS 1Power Supply V/ph/Hz 220-240/1/50 220-240/1/50
Operation mode Economy Economy
Room temperature ºC -7~43 -7~43
Heating capacitykW 1.45 3
kCal/h 1.25 2.58
Nominal input kW 0.38 0.80
Cop 3.8 3.76
Rated current A 2.3 4.1
Water flow rate m3/h 0.043 0.086
Electrical resistor kW 3 3
Compressor type Rotary Rotary
R134a refrigerant volume Kg 1 1.2
Safeguards High pressure, overload, electrical leakage
Evaporator material Hydrophilic aluminium fin, inner-grooved copper tube
Water pipeline
Output water temper-ature ºC
Default 60ºC (Adjustable: 38ºC-70ºC)
Default 55ºC (Adjustable: 38ºC-65ºC)
Heat exchanger Copper tubing around the tank
Water inlet mm DN 20 DN 20
Water outlet mm DN 20 DN 20
Drainage pipe mm DN 20 DN 20
Safety valve mm DN 20 DN 20
Max. Pressure MPa 1 1
Dimensions mm Ø568x1760 Ø650x1920
Tank volume l 190 300
Net weight Kg 107 145.5
Sound Pressure Level dB (A) 41.2 45
Air intake and outlet
Diameter mm ø160 ø190
Static Pressure Pa 25 25
Max. Length m - 10
Outdoor airflow m3/h 270/230/182 414/355/312
Anti-legionella function Yes Yes
COMPAK
TECHNICAL SPECIFICATIONS
Go back to General Contents Go back to AQUATIX Index(Index)
292
Design and Install for you
AQ
UA
TIX
DO
ME
STI
C H
OT
WA
TER
COMPAK KHP 35 300 ACS 1
Domestic hot water storage or underfloor heating using heat pump technology. Provides water temperatures of up to 70ºC. It is fitted with a condenser located around the tank to avoid contact between refrigerant and sanitary hot water. It also includes a magnesium protection anode to avoid internal corrosion of the tank.
• Compact design and easy installation.
• LCD screen control display.
• They must be protected against solar radiation
• Built-in relief valve.
COMPAK KHP 15 190 ACS 1
GENERAL CHARACTERISTICS
ECONOMY: only the heating pump operates +ELECTRICAL RESISTOR for heating+HYBRID: use of the heat pump + resistor +MAGESIUM ANODE in all models+
OPERATION MODE
PRICE LIST
MODEL PRICE
COMPAK KHP 15 190 ACS 1 £1,139
COMPAK KHP 35 300 ACS 1 £1,404
Go back to General Contents Go back to AQUATIX Index(Index)
CONDITIONS OF SALE
1. DEFINITIONS
In these Terms and Conditions of Trading: ‘Kaysun UK’ means Kaysun UK,
part of Monodraught Ltd, registered office is at Halifax House, Cressex
Business Park, High Wycombe, Buckinghamshire HP12 3SE, (Company No.
01163485). ‘Buyer’ means the person or firm who acquires the Goods under
the Contract. ‘Conditions’ means these Terms and Conditions of Trading.
‘Contract’ means the contract between Kaysun UK and the Buyer for the
supply of Goods. ‘Goods’ means any Goods sold by Kaysun UK to the Buyer
and unless separately referred to, “Goods” includes any related or connected
services associated with the supply, including any installation, design,
fabrication or construction undertaken by Kaysun UK or its agents. “Order”
means the Buyer’s order for the supply of Goods as set out in the Buyer’s
purchase order form or written acceptance of Kaysun UK’s quotation as the
case may be.
2. CONTRACT
The Buyer’s order constitutes an offer by the Buyer to purchase Goods from
Kaysun UK in accordance with these Conditions. All Orders are accepted by
Kaysun UK subject to the Goods being available. The Order shall only be
deemed to be accepted when Kaysun UK issues a written acknowledgement
of the Order at which point a Contract shall come into existence. These
Conditions apply to the Contract to the exclusion of any other terms and
conditions that the Buyer seeks to impose or incorporate, or which are
implied by trade, custom, practice or course of dealing. Goods shall be
supplied in accordance with Kaysun UK’s acknowledgement of order and
cannot be cancelled, deferred or altered and shall not be subject to reduction
or variation except by mutual agreement confirmed in writing by both
parties and subject to agreement as to related costs.
3. PRICES
All prices quoted by Kaysun UK are valid for a period of six months from the
date of a quotation or from the date of issue of price lists unless otherwise
expressly stated in the quotation or price list. All prices are subject to Valued
Added Tax at the current rate at the time of delivery. All prices quoted are
net trade prices and shall not be subject to retention or net discount, unless
specifically stated in a quotation or acknowledgement of order. Carriage
prices shown in quotations are net prices and are not subject to any discount.
The Buyer will not be entitled to return Goods to Kaysun UK unless Kaysun
UK gives its prior written consent. Kaysun UK’s consent shall always be
subject to (i) the Goods being returned within 90 days of delivery (ii) the
returned Goods being of first class quality and in immediate re-sellable
condition in unbroken packaging, (iii) that the Buyer pays the costs of
returning the Goods to Kaysun UK, and (iv) that the Buyer pays a restocking
charge amounting to 20% of the purchase price for the returned Goods.
Bespoke / Non-Standard Goods subject to a 100% restocking fee. This
provision does not affect the Warranty of Quality at clause 8.
4. DELIVERY
Kaysun UK will use its reasonable endeavours to make deliveries of Goods
on the date/s agreed but time of delivery shall not be of the essence and
Kaysun UK shall not be liable for any delay in delivery for events of Force
Majeure or matters which are the responsibility of the Buyer and shall not
otherwise be liable for delay unless otherwise agreed in writing before
delivery.
5. RISK AND INSURANCE
Risk in the Goods shall pass to the Buyer from the point of delivery to the
Buyer’s address or other agreed place of delivery or on collection by the Buyer
as appropriate, notwithstanding that property in the Goods may be retained
by Kaysun UK in accordance with Clause 7. The Buyer shall be responsible for
effecting its own insurance as appropriate from the date of delivery. Once
the Goods have been delivered or installed the Buyer shall be responsible to
fully protect them and keep them safe.
6. PAYMENT
Payment of any invoice shall become due on the date of Kaysun UK’s
invoice. The final date for payment shall be 30 days after the relevant
invoice becomes due. Amounts unpaid beyond the final date for payment
are payable with interest calculated at the rate of 8% over the base rate of
the Bank of England applicable at the final date for payment until payment
is received in full.
Within 5 days of an invoice becoming due, the Buyer shall notify Kaysun
UK of the sum that the Buyer considers to be due at the payment due date
and the basis on which that sum is calculated (‘payment notice’). Not less
than 7 days before the final date for payment, the Buyer may give notice if
it intends to pay less than the notified sum, specifying the sum considered
to be due and the basis on which that sum is calculated (‘pay less notice’).
Unless the Buyer gives a pay less notice then it shall pay the sum in the
payment notice (or in the absence of a payment notice then the sum in
Kaysun UK’s invoice) on or before the final date for payment of the invoice.
Where part delivery or part service work is carried out, a payment on account
will be payable based on Kaysun UK’s invoice for the relevant amount.
The Buyer shall not be entitled to apply any set off against any sums owing
to Kaysun UK under the Contract any other sums owing to Kaysun UK. If the
Buyer fails to make any payment by the final date for payment then without
prejudice to any other rights Kaysun UK reserves the right to; suspend some
or all obligations under the Contract, or terminate the Contract, or take down
and retrieve any Goods previously installed.
7. RETENTION OF TITLE
Title in the Goods shall remain with Kaysun UK until full payment for the
Goods has been received. Until such time, the Buyer shall keep the Goods
free from any charge, lien or other encumbrance whatsoever and identifiable
as the property of Kaysun UK. Until payment in full for the Goods has been
received, Kaysun UK may at any time require the Goods to be returned to
it and if such requirement is not forthwith complied with, it may retake
possession of the Goods and for such purposes is irrevocably authorised to
enter upon any premises (whether or not occupied by the Buyer) and retrieve
the Goods.
8. WARRANTY OF QUALITY
Kaysun UK warrants that from the date of shipment of the Goods that the
Goods shall, conform with the specification set out in Kaysun UK’s quotation
or acknowledgement of order or if there is no such specification, the Goods
will comply with reasonable standards of quality and will otherwise be
reasonably free from material defects in design, materials and workmanship
when under normal use. This warranty shall apply for 5 years, subject to
maintenance being carried out in accordance with Kaysun UK instructions.
Whilst all product information is given in good faith the use or application
of the Goods is outside the control of Kaysun UK and accordingly Kaysun UK
gives no warranty as to the fitness of the Goods for any particular purpose
and any implied warranty or condition (statutory or otherwise) is excluded
insofar as such exclusion is permitted by law, including in regard to the
suitability of the Goods for the structure where the Goods are to be installed.
It shall be the responsibility of the Buyer to obtain its own professional
guidance on such matters.
The Buyer shall make no claim against Kaysun UK in relation to defects in
the Goods (or shortages in delivery) unless the Buyer has notified Kaysun
UK in writing of the same within 24 hours of delivery. The Buyer must notify
Kaysun UK directly about any such claim (including packaging) relating to
carriage.
In the event of a claim, Kaysun UK must be given a reasonable opportunity
of examining the Goods. If asked to do so the Buyer shall return the Goods to
Kaysun UK at the Buyer’s cost. Kaysun UK at its option, may repair or replace
defective Goods, or refund the price of the relevant Goods.
Kaysun UK shall be under no liability in respect of defects arising from;
the acts or omissions of persons other than Kaysun UK or its authorised
personnel or agents, including but not limited to damage in transit, repairs,
modifications or additions made to the Goods by the end-user or any
other third party; failure to perform appropriate maintenance; continued
use of the Goods after they exhibit signs of any defect or malfunction;
carelessness, mishandling, wear and tear, vandalism or unforeseen events;
use of the Goods contrary to Kaysun UK’s recommendations; any failure or
defect in related products or systems which the Goods have been integrated
with, operate with or are dependent on; defects in materials or workmanship
which are the result of installation by persons other than Kaysun UK.
Kaysun UK shall be under no liability for variations in predicted performance
as compared to performance under actual weather and temperature
levels. Kaysun UK provides calculations and building simulations based on
simulated weather files in accordance with industry standards.
Nothing in these Conditions shall limit or exclude Kaysun UK’s liability for,
death or personal injury caused by its negligence, or the negligence of its
employees, agents or subcontractors; fraud or fraudulent misrepresentation;
or breach of relevant statutory provisions, subject to which Kaysun UK
shall under no circumstances whatever be liable, whether in contract, tort
(including negligence), breach of statutory duty, or otherwise, for any loss
of profit, or any indirect or consequential loss arising under or in connection
with the Contract; and its total liability to the Buyer in respect of all other
losses arising under or in connection with the Contract, whether in contract,
tort (including negligence), breach of statutory duty, or otherwise, shall in no
circumstances exceed the value of the Goods and after taking into account
what is fair and reasonable allowing for the relative contributions to any loss
suffered by the Buyer of Kaysun UK and other parties who have entered into
any arrangements (contractual or otherwise) with the Buyer in connection
with the Goods or related project or works.
Except as set out in these Conditions, all warranties, conditions and other
terms implied by statute or common law are, to the fullest extent permitted
by law, excluded from the Contract.
Kaysun UK will at its sole discretion undertake for the Buyer or any end user
of the Goods, the repair or replacement of the relevant Goods at its own
cost and so that the Goods conform to the Contract. If however in Kaysun
UK’s reasonable opinion, the end-user is unable to establish a failure on
Kaysun UK to comply with the Contract then the Buyer shall be responsible
for all costs and expenses incurred by Kaysun UK in investigating any alleged
breach.
9. FORCE MAJEURE
Notwithstanding any agreement to the contrary, any delivery may be totally
or partially suspended by Kaysun UK as a result in delay in manufacture,
supply or delivery arising from acts of God, unforeseeable circumstances,
acts of Government or local authority, war, revolution, fires, ice, strikes,
industrial disputes, inability to obtain necessary and proper materials,
facilities, transportation or labour or any other cause beyond Kaysun UK’s
control. Any Goods, the delivery of which has not been totally or partially
suspended shall be accepted by the Buyer as soon as it is reasonably
practicable after the reason for delay has abated.
10. TERMINATION
Either party may terminate the Contract with immediate effect by giving
written notice to the other party if; the other party commits a material breach
of its obligations under the Contract and fails to remedy that breach within
14 days after receipt of the written notice; or the other party suspends, or
threatens to suspend, payment of its debts or is unable to pay its debts as
they fall due or admits inability to pay its debts or; a petition is filed, a notice
is given, a resolution is passed, or an order is made, for or in connection with
the winding up or bankruptcy of the other party; an application is made to
court, or an order is made, for the appointment of an administrator; or a
receiver is appointed over the assets of the other party; or any event occurs,
or proceeding is taken, with respect to the other party that has an effect
equivalent or similar to any of the aforementioned events.
In the event of any termination of a Contract by the Buyer prior to any
goods or services being provided, the buyer shall pay a cancellation charge
amounting to 15% of the purchase price of the Contract.
On termination of the Contract for any reason; the Buyer shall immediately
pay all of Kaysun UK’s outstanding unpaid invoices and interest and shall
return all of the Goods which have not been fully paid for. If the Customer
fails to do so, then the Supplier may enter the Customer’s premises and
take possession of them. Until they have been returned, the Customer shall
be solely responsible for their safe keeping and will not use them for any
purpose not connected with the Contract.
The accrued rights and remedies of the parties as at termination shall not
be affected, including the right to claim damages in respect of any breach
of the Contract, which existed at or before the date of termination or expiry;
and clauses which expressly or by implication have effect after termination
shall continue in full force and effect.
11. LAW
The Contract shall be subject to English law and the English Courts. A
person who is not a party to the Contract shall not have any rights under
or in connection with it. Either party may refer a dispute arising under
the Contract to adjudication at any time under Part I of the Scheme for
Construction Contracts (England and Wales) Regulations, which Part shall
take effect as if it was incorporated into this clause.
12. SPECIFICATIONS AND IMAGES
Kaysun UK reserves the right to change the specifications and images of the
Goods without prior notice.
Kaysun UK
1st August 2017
These Terms and Conditions supersede
all previous Terms and Conditions.