+ All Categories
Home > Documents > KAYSUN UK - Squarespace

KAYSUN UK - Squarespace

Date post: 23-Apr-2023
Category:
Upload: khangminh22
View: 0 times
Download: 0 times
Share this document with a friend
295
2017 PRODUCT CATALOGUE KAYSUN UK HVAC systems
Transcript

2017

PRODUCT CATALOGUEKAYSUN UK

HVAC systems

www.kaysun.co.uk

Design and Install for you

The total or partial reproduction of this catalogue without the express authorisation of Kaysun UK is prohibited.

Design and Install for youGENERAL CONTENTS

GENERAL CONTENTS

TWINS ...................................................................................................... 118SUPERSLIM CASSETTE .......................................................................... 119

CEILING / FLOOR .................................................................................... 119

DUCTS ...................................................................................................... 119

HIGH-CAPACITY ZEN COMMERCIAL RANGEINTRODUCTION TO THE RANGE ..................................................................122

HIGH-CAPACITY SETS OF DUCTS .............................................................123

AIR-COOLED ............................................................................................124

WATER-COOLED .................................................................................... 128

STATIC PRESSURE GRAPHS ................................................................. 130

VRF INDUSTRIAL AMAZON RANGEINTRODUCTION TO THE PRODUCT RANGE ... ...........................................134INDOOR UNITS ............................................... .......................................141

WALL ..................................................................... .KAYF.......................143

DOUBLE FLOW CONSOLE .......................................KSDF......................145

FLOOR STANDING EXPOSED/CONCEALED...........KS(E)F.....................147

CEILING / FLOOR ....................................................KPCF.......................149

ONE WAY CASSETTE...............................................KCOF.......................151

CASSETTE ART FLUX 360º (600x600)..............KCIF........................153

CASSETTE ART FLUX 360º ....................................KCIBF......................155

DUCTS .......................................................................KPDF......................157

STATIC PRESSURE GRAPHS........................................................... 161

HIGH PRESSURE DUCTS ........................................KPDHF....................165

KAHU ....................................................................... KAHU.....................169

DOMESTIC HOT WATER RECOVERY KIT ................ KWF.......................171

OUTDOOR UNITS ........................................................ ..............................1742 PIPES .......................................................... .........................................176

MINI AMAZON VRF

SINGLE PHASE ..................................................KMF DVN...............178

THREE-PHASE.....................................................KMF DTN2............ 180

AMAZON UNITARIO SIDE AIR DISCHARGE...........KMF........................182

AMAZON UNITARIO TOP AIR DISCHARGE...........K2UF.......................184

AMAZON IV PRO .................................................... K2FDN4S................186

AMAZON III W ........................................................K2F DN3W..............188

3 PIPES ......................................................................................................... 190

AMAZON III PRO .....................................................K3F DN3S...............192

KVB BOXES....... .............................................. KVB.........................194

SIZING ........................................................... ......................................... 196DISTANCES AND HEIGHT DIFFERENCES ...... .......................................... 202

CONTROLS CONTROL SYSTEM RANGEINTRODUCTION TO THE RANGE ..............................................................210

UNITSWIRELESS SINGLE AND WIRED CONTROLLERS................................212

CENTRALISED.........................................................................................214

BMS & SOFTWARE.................................................................................216

ACCESSORIES.........................................................................................224

SUITE RESIDENTIAL PRODUCT RANGESUITE 1X1 ...................................................................................................22

INTRODUCTION TO THE PRODUCT RANGE.........................................22SETS ....................................................................................................26

PRODIGY ............................................................................................ 28

AUREA II R-410A .............................................................................. 30

AUREA II R-32 .................................................................................. 32

ONNIX ............................................................................................... 34

DOUBLE FLOW CONSOLE ................................................................ 36

MULTISYSTEM SUITE .................................................................................38INTRODUCTION TO THE PRODUCT RANGE.........................................38R-410A MULTISYSTEM RANGE .......................................................... 40

PRODIGY ............................................................................................ 42

AUREA II R-410A ............................................................................. 44

ONNIX ................................................................................................ 46

DOUBLE FLOW CONSOLE ................................................................48

CASSETTE ........................................................................................ 50

DUCT ................................................................................................. 52

STATIC PRESSURE GRAPHS .................................................... 54

OUTDOOR UNITS .............................................................................. 56

COMBINATION TABLES ................................................................... 58

R-32 MULTISYSTEM RANGE .............................................................. 68AUREA II R-32 ................................................................................... 68

OUTDOOR UNITS .............................................................................. 70

COMBINATION TABLES ....................................................................72

ZEN AXIAL COMMERCIAL RANGEINTRODUCTION TO THE RANGE ................................................................78SETS .......................................................................................................... 80

CASSETTE (600X600) ............................................................................. 82

SUPERSLIM CASSETTE ..........................................................................84

CEILING / FLOOR .....................................................................................88

DUCTS ...................................................................................................... 92

STATIC PRESSURE GRAPHS............................................................ 96

TWINS ......................................................................................................100CASSETTE (600X600) .............................................................................101

SUPERSLIM CASSETTE ..........................................................................101

DUCTS .....................................................................................................102

CEILING / FLOOR ....................................................................................103

ZEN CENTRIFUGAL COMMERCIAL RANGEINTRODUCTION TO THE RANGE .............................................................. 106SETS .........................................................................................................108

SUPERSLIM CASSETTE .......................................................................... 110

CEILING / FLOOR .....................................................................................112

DUCTS .......................................................................................................114

STATIC PRESSURE GRAPHS............................................................116

NEXUS CHILLERS RANGEINTRODUCTION TO THE RANGE ..............................................................228CHILLERS .................................................................................................232MINICHILLERS ...............................................................KEM D(V)(T)N........234

MODULAR FULL DC INVERTER CHILLERS ................ KEM DNS3..............236

DIGITAL SCROLL MODULAR CHILLERS .....................KEM DHN3..............238

EXTERNAL HYDRAULIC KITS ..................................... .KH ..........................240

FIXED SCROLL MODULAR CHILLERS ......................... KEM HN3................242

SCREW CHILLERS ........................................................ KEX - A (W)............244

CENTRIFUGAL CHILLERS ............................................................................248

WATER TERMINAL UNITS PRODUCT RANGE FAN COILSINTRODUCTION TO THE RANGE ..............................................................252UNITS

WALL .................................................................. KFC-AY....................255

CEILING / FLOOR ................................................ KFC-S(E)..................257

CASSETTES 600x600 ........................................ KFC-CI ..................... 259

CASSETTES ........................................................ KFC-CIS....................261

DUCTS ................................................................. KFC-PD....................263

HIGH-PRESSURE DUCTS ................................... KFC-PDH..................265

AQUATIX DOMESTIC HOT WATER RANGEINTRODUCTION TO THE PRODUCT RANGE.............................................269UNITS

AQUANTIA ............................................................ MONOBLOC.............277

AQUANTIA ............................................................ SPLIT.......................281

DOMESTIC HOT WATER DEPOSITS .................... BS, G........................285

SWIMMING POOLS .............................................. KSWP......................289

COMPAK ................................................................ KHP ACS..................291

Spare PartsKAYSUN also has a spare parts business, the aim of which is to provide the best possible service with delivery within 24h and specialist advice and service for each product over the phone, so as to protect the prestige and excellence of the products represented.

After-sales serviceTo ensure the quality of service at all stages of its value chain, KAYSUN has a highly specialised after-sales service area to foster the agile and effective resolution of any issues that may

arise.

KAYSUN spare parts• 30,000 parts in stock.

• + 200 shipments daily.

KAYSUN after-sales service• ISO 9001 and ISO 14001

• Uninterrupted service all year round (24/7 in the transport unit).

The manufacturer of one in every five air conditioning units worldwide

HVAC systemsKAYSUN UK has an alliance with Midea, a world leader in air treatment equipment, to offer integrated climate control projects suitable for all types of installations, from the residential range to the industrial range. KAYSUN is also present in leading projects worldwide, with which it has experienced

rapid expansion.

Great versatility of equipment and advanced technological innovation.

6

Design and Install for you

Go back to General Contents (Index)

OUR ORIGINS

“A well-established Team”

Kaysun is a brand that covers air conditioning and thermal solar energy solutions. Kaysun has a successful and well-known background thanks to over ten years of experience. The company provides air conditioning solutions for both domestic and commercial use, with excellent case studies, including the Barcelona Hilton Hotel. Kaysun has an outstanding presence and international profile, with distributors in France, Morocco, Ireland, Italy, Andorra and Portugal. We are now pleased to bring the product set to the UK.

Kaysun is distributed in the UK by Monodraught Ltd. We are the innovators in our field and for over 40 years have consistently been at the forefront of designing, manufacturing and installing natural ventilation, lighting and cooling products. Our objective is to provide architects, consultants, contractors and building owners with high quality, low maintenance solutions. We deliver the whole Kaysun solution using our in-house team of quotations specialists, IES modellers, controls experts, commissioning and installation engineers. This ensures that we are able to implement our solutions in a fully supported, quality guaranteed environment.

EuropeFrance

England

Ireland

Italy

Portugal

Spain

Andorra

Belgium

The Netherlands

Luxembourg

Slovenia

Malta

Romania

7 Go back to General Contents (Index)

8910

COMMITTED TO THE ENVIRONMENT

Our equipment is manufactured almost entirely from recyclable materials. We have reduced consumption

as far as possible in STANDBY mode and have

improved the energy efficiency of units working at full

capacity, resulting in energy savings for facilities.

1 6

7234

5

“Ten reasons why we stand out”

THE KAYSUN UK GUARANTEE

KAYSUN UK is known for its premium products and

its broad experience in excellent after-sales services.

KAYSUN UK, the company's own brand, was developed

with the standards for quality and technological

innovation that have always set us apart.

MAXIMUM RELIABILITY OF OUR EQUIPMENT

We guarantee that our units will have a long service

life, thanks to top-quality materials. This ensure that

the need to make use of their warranties is reduced

to a minimum.

ISO 9001 / ISO 14001

The quality of our products and environment benefits

are two key pillars for KAYSUN. We are proud to have

achieved ISO 9001 and ISO 14001, under the seal of

Frigicoll.

WIDE RANGE

We offer comprehensive solutions for any facility thanks

to the diversity of our product ranges. From residential

split systems to the most complex water terminal units,

and including air curtains, recovery systems, VRFs, chillers,

solar and domestic hot water units.

COMPREHENSIVE PROJECTS

Our team of expert technicians carries out HVCA and

ventilation comprehensive specific projects for every

single customer, which allows our company to be able

to adapt to any space and need. A personalised advice

complements this service, thus ensuring the correct

performance of our installation works.

CUTTING-EDGE TECHNOLOGY

Our forward-looking approach goes hand-in-hand

with the incorporation of the latest technology in all

of our equipment. We include features that improve

everything from energy consumption to practicality

and comfort, as in the case of the built-in motorised panel used in the cassettes.

SMART CONTROL

Our smart control devices, allow us to offer comfort

and well-being in any facility. The K01-WIFI device is

the first smart solution for our units, providing the

option of programming and managing air conditioning

units inside and outside your home.

EXCELLENT AFTER-SALES SERVICE

We work to solve all incidents as quickly as possible, leaving our customers completely satisfied with

our after-sales service. We have a team of expert

professionals working for you.

DESIGN AND INSTALL

Our team in the UK are proud to take you project and

provide a design to fit your requirements. We manage

the whole process through to installation and beyond.

ISO

8

Design and Install for you

Go back to General Contents (Index)

Icons for the 2017 catalogue.

Green colour, which stands for ecological innovation, is hard to miss in our 2017 catalogue, showing the energy efficiency of each of our products.

EUROPEAN DIRECTIVE ErP

ECODESIGN DIRECTIVE

On January 1st, 2013 the "ecodesign" directive took effect,

which in order to reduce energy consumption and benefit

the environment, requires the adoption of legal measures

to establish requirements for energy labelling and supplying

energy-related information about products.

The Commission adopted Regulation 626/2011, introducing

the new energy labels which are mandatory for air conditioning

units connected to the grid with a nominal refrigerating power

(or nominal heating power, if the unit only runs as a heat pump) of less than 12kW.

These labels contain seasonal energy performance levels, which are based on different outdoor temperatures and part-

load efficiencies to calculate a level of annual consumption in

extremely close detail, thus demonstrating in the most apparent

manner possible the advantages of the Inverter technology used by KAYSUN UK. The sound level rating of the unit is also

displayed.

It is important to make the distinction between SEER and SCOP, where “S” stands for “Seasonal” to indicate the seasonal

variation of annual energy consumption, which is usually

measured according to the hours a unit runs in different climatic

zones over a year.

EUROPEAN DIRECTIVE ErP

CLASSES* SEER SCOP

A+ + + SEER ≥ 8.50 SCOP ≥ 5.10

A+ + 6.10 ≤ SEER < 8.50 4.60 ≤ SCOP < 5.10

A+ 5.60 ≤ SEER < 6.10 4.00 ≤ SCOP < 4.60

A 5.10 ≤ SEER < 5.60 3.40 ≤ SCOP < 4.00

B 4.60 ≤ SEER < 5.10 3.10 ≤ SCOP < 3.40

C 4.10 ≤ SEER < 4.60 2.80 ≤ SCOP < 3.10

D 3.60 ≤ SEER < 4.10 2.50 ≤ SCOP < 2.80

ENERGY EFFICIENCY CLASSES for air conditioners

Minimum energy efficiency values have been established for both

cooling and heating mode for all products for sale after January

2013 to which that regulation applies. Inefficient products will not

be able to be sold on the European market, since they do not meet

the requirements of the mentioned regulation.

(*) with the exception of dual and single duct units.

KAYSUN UK offer a complete design and install for you solution. Our credentials in the sustainable building industry

mean that we are proud to present a 2017 catalogue in

which all products meet the requirements of the new energy

regulations in force. SCOPErP SEER

9 Go back to General Contents (Index)

ENERGY LABELS

The label makes a distinction between

climatic areas, and therefore offers users

more detailed information and a more

accurate idea of the efficiency of the units

according to the climatic area in which they

are located.

In addition to the Ecodesign directive,

there is another directive hat that affects

KAYSUN. All units with fans with a motor

that consumes between 125W and 500 kW

of energy meet certain minimum energy

efficiency requirements.

SEER and SCOP. These values indicate

the Seasonal Energy Efficiency Ratio for

refrigerating (SEER) and heating (SCOP)

calculated based on annual hours of use

in different climatic zones.

ENERGY CLASS For heating and cooling,

labels will increase up to Class A+++.

SOUND LEVELS The sound level of indoor

and outdoor units, expressed in decibels.

CLIMATIC ZONES The map below shows

the three climatic zones that have been

established for a better evaluation:

Average (*) Annual temperature of

Strasbourg.

Hot Annual temperature of Athens.

Cold Annual temperature of Helsinki.

NOMINAL POWER ACOUSTIC POWER IN dB(A)

≤ 6kW

Indoor 60

Outdoor 65

≤ 12kW

Indoor 65

Outdoor 70

MINIMUM ENERGY EFFICIENCY REQUIREMENTS

MINIMUM ENERGY EFFICIENCY REQUIREMENTS 2015NOMINAL POWER

GWP OF THE REFRIGERANT AIR CONDITIONERS DUAL DUCT SINGLE DUCT

SEER SCOP EER Cop EER Cop

< 6KWIf the GWP > 150 4.60 3.80 2.60 2.60 2.60 2.04

If the GWP < 150 4.14 3.42 2.34 2.34 2.34 1.84

6 - 12 KWIf the GWP > 150 4.30 3.80 2.60 2.60 2.60 2.04

If the GWP < 150 3.87 3.42 2.34 2.34 2.34 1.84

We would like to note that there are also restrictions regarding sound levels, and therefore KAYSUN UK offers efficient and

environmentally friendly products that provide comfort and a quality lifestyle to end users.

(*) It is only mandatory to express the SCOP for the

average climate zone.

10

Design and Install for you

Go back to General Contents (Index)

OUR PRODUCT RANGE

11 Go back to General Contents (Index)

2.0 2.6 2.8 3.5 4.2 4.8 5.2 6.2 7.1 7.8 8.0 10.5 12.0 14.0 16.0 kW pag.

SU

ITE

1X

1

PRODIGY 30

AUREA II R-410A 32

AUREA II R-32 34

ONNIX 36

CONSOLE 40

MU

LTIS

YS

TEM

R-4

10A

PRODIGY 44

AUREA II 46

ONNIX 48

CONSOLE 50

CASSETTE 52

DUCTS 54

OUTDOOR 58

R-3

2

AUREA II 70

OUTDOOR 72

SUITE RESIDENTIAL PRODUCT RANGE

2x

2x

2x

3x

3x

3x

4x

4x

5x

5x

NEW

NEW

NEW

NEW

NEW

12

Design and Install for you

Go back to General Contents (Index)

OUR PRODUCT RANGE

ZEN COMMERCIAL RANGE

2.6 3.5 5.2 7.1 9.0 10.5 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 56.0 kW pag.

AX

IAL

1X1

SY

STE

MS

600x600 CASSETTE 84

SUPERSLIM CASSETTE 86

FLOOR-CEILING 90

DUCTS 94

TWIN

S

600x600

CASSETTE103

SUPERSLIM CASSETTE 103

FLOOR-CEILING 104

DUCTS 105

CEN

TRIF

UG

AL

1X1

SY

STE

MS

SUPERSLIM CASSETTE 112

FLOOR-CEILING 114

DUCTS 116

TWIN

S

SUPERSLIM CASSETTE 121

FLOOR-CEILING 121

DUCTS 121

HIG

H C

APA

CITY

AIR

CO

ND

ENSE

D

FRONT AIR DISCHARGE

126128

VERTICAL AIR DISCHARGE

126128

WA

TER

CO

ND

ENSE

D

130

13 Go back to General Contents (Index)

SUITE ZEN AMAZON

PRODIGY AUREA II ONNIX CONSOLE MULTI pag.

WIR

ELE

SS KID-02 S 216

KI-02.3 S 216

IND

IVID

UA

L W

IRED

KC-01 S

except for Aurea, Onnix and Cassette 840x840 models

except cassette

840x840216

KC-03 SPS

ducts and columns only 217

KC-02.1 H

except for Aurea, Onnix and Cassette 840x840 models

except cassette

840x840217

KCT-02.1 SR

except for Aurea, Onnix and Cassette 840x840 models

217

CEN

TRA

LISE

D C

ON

TRO

LS

KMC-32 E 218

KCC-64 I-PS

except wall-mounted 218

KCC-64 I PS

except wall-mounted 218

KCC-16

except wall-mounted 219

KCC-64 WEB

except wall-mounted 219

INTE

GRA

TED

CO

NTR

OLS

K01-LON

except wall-mounted 220

K01-BACNET

except wall-mounted 222

K02-MODBUS

except wall-mounted

221

K03-MODBUS

ducts and columns only

221

KAYNET CONTROL

except wall-mounted

226

K01-KNX

except wall-mounted 223

K01 WIFI 224

ACC

ESSO

RIE

S

K01-WATT

except for Mini-Amazon II

229

KAHU

except for Mini-Amazon II and

Amazon III 3 pipes

228

INTERFACE XYE ON

Only KSD

229

CONTROLS CONTROL SYSTEM RANGE

NEW

NEW

14

Design and Install for you

Go back to General Contents (Index)

OUR PRODUCT RANGE

1.5 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.0 14.0

IND

OO

R U

NIT

S

WALL-MOUNTED

DOUBLE FLOW CONSOLE

FLOOR STANDING EXPOSED/

CONCEALED

FLOOR / CEILING

CASSETTE 1 VÍA

CASSETTE 600X600

CASSETTE 840X840

DUCTS

HIGH PRESSURE DUCTS

AIR CONDITIONING RECOVERY KIT

KAHU

OU

TDO

OR

UN

ITS

2 P

IPE

S

MINI-AMAZONSINGLE-PHASE

MINI-AMAZONTHREE-PHASE

AMAZON SINGLE FRONT AIR

DISCHARGE

AMAZON SINGLE VERTICAL AIR

DISCHARGE

AMAZON IV PRO

AMAZON III W

3 D

UCT

S

AMAZON III PRO

AMAZON INDUSTRIAL VRF RANGE

NEW

NEW

15 Go back to General Contents (Index)

16.0 18.0 20.0 22.4 25.0 25.2 26.0 28.0 33.5 40.0 45.0 50.0 56.0 61.5 67.0 73.0 75.0 kW Pag.

146

148

150

152

154

156

158

160

168

174

172

182

184

186

188

190

192

196

16

Design and Install for you

Go back to General Contents (Index)

FANCOILS WATER TERMINAL UNITS PRODUCT RANGE

425 510 680 850 1020 1250 1360 1530 1600 1700 2000 2380 2550 3060 3740 m3/h pag.

IND

OO

R U

NIT

S

WALL-

MOUNTED

2 PIPES260

FLOOR / CEILING

2 PIPES

EXPOSED 262

CONCEALED 262

CASSETTE 600 X 600

2 PIPES 264

4 PIPES 264

OUR PRODUCT RANGE

5 7 10 12 14 16 26 30 35 52 65 71 95 130 160 195 200 225 250 260 315 340

CHIL

LER

S

MINICHILLERSINVERTER

Single-phase

Three-phase

MODULAR FULL DC

INVERTER CHILLERS

Withouthydraulic kit

With hydraulic kit

MODULAR CHILLERS

Digital Scroll

Fixed Scroll

ROTARY SCREW

CHILLERS

Air-water

Water-water

2 3 4 5

CHILLERS CENTRIFUGAL

4x

4x

4x 4x 4x

4x

4x

NEXUS CHILLERS PRODUCT RANGE

17 Go back to General Contents (Index)

380 400 435 440 500 510 520 540 565 600 620 630 640 685 690 720 740 750 760 805 815 900 1000 1100 1200 1385 1620 1780 kW pag.

238

238

240

240

242

246

248

250

6 7 8 9 10 mW

252

425 510 680 850 1020 1250 1360 1530 1600 1700 2000 2380 2550 3060 3740 m3/h pag.

IND

OO

R U

NIT

S

CASSETTE

2 PIPES 266

4 PIPES 266

DUCTS

2 PIPES 268

4 PIPES 268

HIGH PRESSURE

DUCTS 2 PIPES 270

18

Design and Install for you

Go back to General Contents (Index)

OUR RANGES

AQUATIX DOMESTIC HOT WATER RANGE

150 200 250 300 350 L pag.

HE

AT

PU

MP

COMPAK 296

SWIMMING POOLS

4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 15000 16000 17000 18000 W

294

100 200 350 500 750 1000 1250 1500 1750 2000 2225 2500 L pag.

DE

PO

SIT

S DEPOSITS FOR

DOMESTIC HOT WATER

290

4 5 6 7 8 12 14 16 kW pag.

AQ

UA

NTI

A S

ING

LE B

LOC

SINGLE-PHASE 282

THREE-PHASE 282

4 5 6 7 8 12 14 16 kW pag.

AQ

UA

NTI

A S

PLI

T SINGLE-PHASE 286

THREE-PHASE 286

AUTOMATIC ADJUSTMENT OF THE BLADES The unit has the capacity to automatically position the blades at the same angle that they were at when it was shut off the last time.

AUTO SWING The wide angle of rotation of the horizontal and vertical blades guides the cold or hot air, creating a flow capable of reaching any corner of the space.

AIR OUTLET The unit has two air outlets: upper and lower.

AIR OUTLET 360º The indoor unit is capable of spreading a 360º air flow, thus providing high comfort and reaching all corners of the room.

AIR INTAKE The indoor unit has two possible air intakes: the upper and the rear intake.

FRESH AIR SUPPLY “X %” of fresh air directly enters the indoor unit through an orifice.

MULTIPLE AIR INLETS This unit is fitted with four air return inlets: upper inlet, lower inlet, right inlet and left inlet.

R410A ECOLOGICAL REFRIGERANT The ecological refrigerant R410A causes no damage to the ozone layer, helping minimize our impact on the environment.

R134A REFRIGERANT R134A ecological refrigerant.

R-32 REFRIGERANT The unit works with R-32 ecological refrigerant.

DRAINAGE PUMP A system which is capable of removing condensate up to 750 mm.

ADDRESSING The control system allows setting an address for indoor units inside the communication bus.

TWO COMMUNICATION WIRES The system uses two shielded communication wires without polarity.

HERTZ The units can function at 50 or 60 Hz.

TWINS Connection system that allows the two indoor units to be combined with an outdoor unit, making installation easier and more economical.

MOTORIZED PANEL This type of panel descends automatically by up to 4 metres to facilitate the maintenance and cleaning of the filter.

SOLAR PANEL A very efficient set of equipment which exploits the sun's energy using a solar panel.

TECH

NOL

OGY

DIGITAL SCROLL A compressor with digital scroll technology that provides total control over the capacity and power of the system in accordance with the needs of each indoor unit.

3D TECHNOLOGY Triple DC inverter technology that allows a more constant temperature, high energy saving and significant energy efficiency.

HYDRAULIC KIT A complete, built-in hydraulic kit.

SCROLL The unit is fitted with a highly efficient and powerful scroll compressor.

DC INVERTER COMPRESSOR This feature allows to regulate the power of the compressor, providing optimum control and extremely efficient operation.

CONDENSATION CONTROL Allows the system to refrigerate, even with low outdoor temperatures.

DC INVERTER INTERNAL FAN The unit is fitted with a DC Inverter internal fan.

DC INVERTER EXTEERNAL FAN The unit is fitted with a DC Inverter external fan.

SIMULTANEOUS COOLING/HEATING Heat recovery technology which allows cold and heat to be obtained simultaneously within the same system, optimising the user's comfort.

COOLING AND HEATING Our units are equipped with air conditioning and a heat pump.

ROTARY Unit fitted with a rotary heat exchanger to provide a higher air flow.

SCREW COMPRESSOR Unit fitted with a screw compressor suitable for high compression ratio.

MODULAR Can be combined with other units up to power "x", by connecting the inlet and outlet pipes between units.

COMPACTA Advances in design have reduced the size of the indoor and outdoor units without overlooking any technological details.

SUPER SLIM The new Super Slim cassette can be fitted into any space.

SEER Classification of energy efficiency according to seasonal performance for cooling.

SCOP Classification of energy efficiency according to seasonal performance for heating.

SCOP 4.0 The heat pump performance of a set of units exceeds SCOP 4.0.

ERP Unit that complies with the European Parliament and Council of the European Union's Directive which establishes the ecological design requirements applicable to products that use energy.

ENER

GYRE

FRIG

ERAN

T

AIR

DIST

RIBU

TION

DESI

GN

LED DISPLAY The indoor unit displays the information on a digital display panel.

COMPENSATION TEMPERATURE The possibility of compensating for the difference in temperature between the indoor unit's sensor and the real temperature of the room in heating mode.

8ºC HEATING This feature keeps the temperature in the room from dropping below 8ºC by turning on the unit automatically in heat mode until it reaches 17ºC.

REFRIGERANT CONTROL A sensor on the outdoor unit and an alarm on the indoor unit's display alert the user of the detection of a possible refrigerant leak.

AUTOMATIC MODE The indoor unit automatically changes to heating or cooling operating mode based on the temperature selected.

NIGHT MODE A feature of the indoor unit which reduces the sound level during the night for a more comfortable sleep.

EYE DETECTOR A function that automatically turns off the unit when the sensor does not detect movement in the room for 30 minutes. The unit will switch on again when someone enters the room.

FOLLOW ME A feature which changes the operating mode based on the remote controlled temperature sensor with the aim of maintaining maximum comfort.

WEEKLY PROGRAMMER A control feature which schedules when the unit will turn on/shut off according to the day and time during the week.

SELF-CLEANING A feature of the indoor unit which automatically cleans the machine's battery so as to continue providing fresh, purified air every day.

TURBO MODE This feature reaches the selected temperature within a very short time.

SILENCE MODE A function of the indoor unit that reduces sound pressure using the lowest speed of the fans.

ECO MODE A control feature which reduces consumption, offering high energy efficiency thanks to automatic temperature regulation.

STAND BY The "standby mode" feature allows 80% energy saving with only 1W consumption by the LED display.

INTELLIGENT This feature allows changing the operation parameters of the unit and extracting operation data.

SWITCH OFF DISPLAY This feature allows switching off the display of the indoor units, if necessary.

Wi-Fi This unit can be controlled by a Wi-Fi network through a smartphone application.

LOW SOUND LEVEL New technological advances have allowed the level of sound produced by the indoor units to be reduced by up to 20 dB.

MUTE This feature allows permanently cancelling the indoor unit alarm beeper.

COM

FORT

COM

FORT

INST

ALLA

TION

AN

D SE

RVIC

E

DOMESTIC HOT WATER A system that produces domestic hot water and underfloor heating.

TOUCH SENSITIVE KEYS The keys of the remote control are touch sensitive

ICONS DESCRIPTION

SUITERESIDENTIAL PRODUCT RANGE

21

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

SUITERESIDENTIAL PRODUCT RANGE

SUITE 1X1...............................................................................................22

INTRODUCTION TO THE PRODUCT RANGE ..........................22

SETS ..........................................................................................26

PRODIGY .............................................................................28

AUREA II R-410A ...............................................................30

AUREA II R-32 ...................................................................32

ONNIX ................................................................................34

DOUBLE FLOW CONSOLE .................................................36

MULTISYSTEM SUITE ...........................................................................38

INTRODUCTION TO THE PRODUCT RANGE ..........................38

R-410A MULTISYSTEM RANGE ..............................................40

PRODIGY .............................................................................42

AUREA II R-410A ..............................................................44

ONNIX .................................................................................46

DOUBLE FLOW CONSOLE .................................................48

CASSETTE .........................................................................50

DUCT ..................................................................................52

STATIC PRESSURE GRAPHS ................................54

OUTDOOR UNITS ..............................................................56

COMBINATION TABLES ....................................................58

R-32 MULTISYSTEM RANGE ...................................................68

AUREA II R-32 ....................................................................68

OUTDOOR UNITS ..............................................................70

COMBINATION TABLES ....................................................72

BUSINESS GROUP

22

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

RESIDENTIAL PRODUCT RANGESUITE 1x1

“ELEGANCE AND COMFORT

FOR YOUR HOME”

We present the KAYSUN UK 2017 1x1 range of residential units. KAYSUN UK endeavours to offer the most complete range suitable for any type of aesthetic and requirement. Contributing to the maximum well-being of the user, at the vanguard of innovation and with a proposal that meets all of the requirements of the market and contains developments that constitute pioneering advances in the sector.

The residential range units comply with the ERP (energy-related products) directive of the EU, offering SCOP values of A, A+ and A++. The brand wishes to consolidate its position in the market by offering products with a seasonal energy

efficiency under heat mode that are even higher than 4 in SCOP for some of its models. Therefore, we not only observe the current directives on energy efficiency, but future directives as well.

INSTALLATION

MAINTENANCE

INTERACTIVITY

EFFICIENCY+

+

++

PRODIGYIn its search for the best combination of efficiency and comfort, KAYSUN UK brings professional technological development to the end-user. The PRODIGY unit has been created to become the new emblem of domestic split equipment, and is positioned in the market as an unbeatable commitment to our fundamental values.

RESIDENTIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

23

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

INSTALLING

• Installation template included and integral plate, strong and simple support. When installing the unit, you have a 50mm side shift margin.

• The unit's support is fitted with a hinge system, which provides a 168 mm opening to allow a comfortable cooling pipe connection.

MAINTENANCE

EASY AND COMFORTABLE ACCESS TO THE FILTER WITHOUT DISASSEMBLING THE UNIT

FAN MAINTENANCE WITHOUT TAKING THE UNIT OFF THE WALL.

SIMPLE AND QUICK OPENING THANKS TO ITS ROTATING FRONT PANEL.

EASY ACCESS TO EVAPORATOR IN CASE THAT CLEANING OR REPLACEMENT TASKS ARE REQUIRED.

EASY ACCESS TO ELECTRONIC BOARD AND TO THE COMPLETE ELECTRICAL PANEL TO PERFORM CHECKING OR REPLACEMENT OPERATIONS.

+

++

++

• Fasteners system for supporting front panel while working on electrical connections.

• The electric terminal board is wide and strong.

BUSINESS GROUP

24

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

AUREA II

This year KAYSUN UK presents AUREA II, its new medium-range unit, within its residential wall type units. With its elegant design, the main characteristic of this unit is that it functions with R-32 or R-410A refrigerant and incorporates all KAYSUN UK technology, with the most advanced functions in the range as a result.

WIFI CONTROL (OPTIONAL)+

R-32 AND R-410A REFRIGERANT+LEAKAGE DETECTION SYSTEMS

SCOP OVER 4.0++

PARAMETERS AND CONFIGURATION BY REMOTE CONTROLLER+

GREATER OUTPUT+ENERGY SAVING+SOUND LEVELS REDUCTION+R-410A AND R-32+

OUTDOOR UNITS

We wish to point out the whole range of outdoor units in the KAYSUN UK SUITE RANGE. These are units that provide us with low noise levels, good performance and significant energy savings. A machine designed to make maintenance tasks easier and protects/protecting its main components in order to extend the useful life of the product.

• Strong structure.

• Compact finishing.

NEW

RESIDENTIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

25

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

APP/WIFI

KAYSUN UK has a plug&play WiFi control system. Thanks to our USB accessory, you can quickly and easily configure your split unit through your smartphone.

KID-02 S

The KAYSUN UK SUITE 1X1 RANGE has wireless control of large services and with the most advanced functions.

INSTALLATION PARAMETRES MODIFICATION+OPERATION PARAMETERS CHECKING+FOLLOW ME+

WEEKLY TIMER+CHECK+BASIC FUNCTIONS+

www.kaysun.co.uk

KID-02 S

K03 WIFI USB ACCESSORY

DOWNLOAD OUR APPLICATION FROM:

PLUG & PLAY+

BUSINESS GROUP

26

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

SETSSUITE 1x1

27

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

2.6 5.23.5 7.1POWER kW

PRODIGY

AUREA II R-32

AUREA II R-410A

ONNIX

DOUBLE FLOW CONSOLE

KAY-26 DN7

KAY-D 26 DN7

KAY-S 26 DR7

KAY-S 26 DNR7

KAY-35 DN7

KAY-D 35 DN7

KSD-35 DVN10

KAY-S 35 DR7

KAY-S 35 DNR7

KAY-52 DN7

KAY-D 52 DN7

KSD-52 DVN10

KAY-S 52 DR7

KAY-S 52 DNR7

KAY-71 DN7

KAY-S 71 DR7

KAY-S 271DNR7

NEW

NEW

DISTANCES AND HEIGHT DIFFERENCES

26 35 52 71

TOTAL LENGTH 25 25 30 50

MAXIMUM HEIGHT 10 10 20 25

BUSINESS GROUP

28

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

ERP

PRODIGYPRODIGY is a KAYSUN UK wall unit that represents a revolution in installation and preventive maintenance*. Easy installation, maintenance and fitted with Kaysun avant-garde TECHNOLOGY.

• SCOP 4.0, over European Directive ERP, for a high energy efficiency.

• Louvres position memory.

• Leakage detection system.

• Compatible with wired controllers.

• Drainage pipe connection from left or right option.

• Self-locking option for Heating-Only function.

• Display and buzzer switch-off to improve ambient comfort.

• Its white translucent smart DISPLAY provides user with information on the equipment and alarm systems status.

• KID-02 S controller included to control unit’s work parameters and change its configuration.

• Mono-Multi compatible.

• Optional WIFI control adding K03 WIFI USB.

K01-WIFIKC-02.1 H KCT-02.1 SRKC-01 S

For further information, please see our Controllers range

INDIVIDUAL

CONTROLLERS

BMS AND SOFTWARE

GENERAL CHARACTERISTICS

WIFI CONTROL (OPTIONAL) +

EASY ASSEMBLY AND MAINTENANCE +ERP

KID-02 SSTANDARD

OPTIONAL WIFI

K03 WIFI USB ACCESSORY

PRICE LIST

SET INDOOR UNIT OUTDOOR UNIT STANDARD CONTROL PRICE SET

KAY-26 DN7 KAY-26 DN7 KAE-26 DN7 KID-02 S £391

KAY-35 DN7 KAY-35 DN7 KAE-35 DN7 KID-02 S £414

KAY-52 DN7 KAY-52 DN7 KAE-52 DN7 KID-02 S £757

KAY-71 DN7 KAY-71 DN7 KAE-71 DN7 KID-02 S £962

ACCESSORIES

MODEL PRICE

K03 WIFI USB ACCESSORY £36

SETSRESIDENTIAL RANGE

29

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

TECHNICAL SPECIFICATIONS

SET KAY-26 DN7 KAY-35 DN7 KAY-52 DN7 KAY-71 DN7Cooling capacity (min./rated/max.) kW 1.17/2.64/3.31 1.26/3.52/4.45 1.90/5.28/6.13 2.67/7.03/7.88

Cooling capacity (min./rated/max.) Kcal/h 1008/2268/2848 1084/3024/3830 1638/4536/5267 2293/6048/6779

Cooling input (min./rated/max.) W 100/816/1270 110/1153/1720 150/1633/2350 230/2306/3030

SEER 6.8 6.7 6.8 6.4

Cooling energy class A++ A++ A++ A++

Heating capacity (min./rated/max.) kW 0.82/2.93/3.72 1.07/3.81/4.86 1.43/5.57/6.74 2.08/7.62/9.14

Heating capacity (min./rated/max.) Kcal/h 706/2520/3200 917/3276/4183 1227/4788/5796 1789/6552/7862

Heating input (min./rated/max.) W 140/811/1330 170/1055/1740 230/1500/2400 310/2302/3270

SCOP 4.1 4.2 4.2 4.0

Heating efficiency class A+ A+ A+ A+

SCOP (warm areas) 5.1 5.2 5.4 5.2

Heating energy class (warm areas) A+++ A+++ A+++ A+++

Heating capacity -7ºC kW 2.12 2.30 3.89 4.95

COP -7ºC 2.88 2.79 2.78 2.48

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

INDOOR UNIT KAY-26 DN7 KAY-35 DN7 KAY-52 DN7 KAY-71 DN7Air Flow m3/h 472/360/254 563/497/224 870/730/500 1176/921/446

Sound pressure* dB (A) 20 22 26 28

Width x Height x Depth mm 717/302/193 805/302/193 964/325/222 1106/342/232

Net weight Kg 7 7.7 10.1 13.2

Power wiring mm2 From outdoor From outdoor From outdoor From outdoor

Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5

OUTDOOR UNIT KAE-26 DN7 KAY-35 DN7 KAY-52 DN7 KAY-71 DN7Compressor type Rotary Rotary Rotary Rotary

Outdoor airflow m3/h 1900 2000 2100 2700

Sound pressure dB (A) 55 56 58 61

Refrigerant R-410 R-410 R-410 R-410

Refrigerant charge / Supplementary charge ** gr 800/15 950/15 1480/15 2000/30

Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8")

Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") ø15.9(5/8")

Max. length piping m 25 25 30 50

Pipe height difference m 10 10 20 25

Width/Height/Depth mm 770/555/300 800/554/333 800/554/333 845/702/363

Net weight Kg 26.6 29.1 37.8 48.4

Power wiring mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5

* Sound pressure in “Silence” mode / **Factory pre-charge for 5 metres of installation / Additional charge for every metre added after 5 metres

Working temperature range: -15ºC to 50ºC (Cooling) / -20ºC to 30ºC (Heating)

BUSINESS GROUP

30

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

AUREA II R-410AAUREA II, the medium-category range of KAYSUN UK, is characterized by its multi-use nature: it can run on R-410A or R-32 refrigerant. In addition to a simple and elegant design, it incorporates all of KAYSUN’s most advanced characteristics and technologies.

• SCOP 4.0, over European Directive ERP, for a high energy efficiency.

• Louvres position memory.

• Leakage detection system.

• Drainage pipe connection from left or right option.

• Self-locking option for Heating-Only function.

• Display and buzzer switch-off to improve ambient comfort.

• White translucent smart DISPLAY with information on the equipment and alarm systems status.

• KID-02 S controller included to control unit's work parameters and change its configuration.

• Mono-Multi compatible.

• Easy installation optional WIFI control adding K03 WIFI USB.

For further information, please see our Controllers rangeCONTROLLERS

BMS AND SOFTWARE

K01-WIFI

GENERAL CHARACTERISTICS

POSSIBILITY TO BLOCK THE UNIT FOR HEATING-ONLY +WIFI CONTROL (OPTIONAL)+

NEW

KID-02 SSTANDARD

OPTIONAL WIFI

K03 WIFI USB ACCESSORY

PRICE LIST

SET INDOOR UNIT OUTDOOR UNIT STANDARD CONTROL PRICE SET

KAY-S 26 DNR7 KAY-S 26 DR7 KAE-26 DN7 KID-02 S £411

KAY-S 35 DNR7 KAY-S 35 DR7 KAE-35 DN7 KID-02 S £433

KAY-S 52 DNR7 KAY-S 52 DR7 KAE-52 DN7 KID-02 S £732

KAY-S 71 DNR7 KAY-S 71 DR7 KAE-71 DN7 KID-02 S £894

ACCESSORIES

MODEL PRICE

K03 WIFI USB ACCESSORY £36

SETSRESIDENTIAL RANGE

31

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

TECHNICAL SPECIFICATIONS

SET KAY-S 26 DNR7 KAY-S 35 DNR7 KAY-S 52 DNR7 KAY-S 71 DNR7Cooling capacity (min./rated/max.) kW 1.17/2.64/3.31 1.26/3.52/4.45 1.90/5.28/6.13 2.67/7.03/7.88

Cooling capacity (min./rated/max.) Kcal/h 1008/2268/2848 1084/3024/3830 1638/4536/5267 2293/6048/6779

Cooling input (min./rated/max.) W 90/750/1270 100/1088/1740 150/1547/2380 230/2261/3110

SEER 7.4 6.8 6.8 6.6

Cooling energy class A++ A++ A++ A++

Heating capacity (min./rated/max.) kW 0.82/2.93/3.72 1.07/3.81/4.86 1.43/5.57/6.74 2.08/7.62/9.14

Heating capacity (min./rated/max.) Kcal/h 706/2520/3200 917/3276/4183 1227/4788/5796 1789/6552/7862

Heating input (min./rated/max.) W 140/770/1340 170/1025/1760 220/1500/2430 320/2320/3320

SCOP 4.2 4.2 4 4

Heating energy class A+ A+ A+ A+

SCOP (warm areas) 5.4 5.2 5.3 5.2

Heating energy class (warm areas) A+++ A+++ A+++ A+++

Heating capacity -7ºC kW 2.12 2.30 3.89 4.95

COP -7ºC 2.88 2.79 2.78 2.48

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

OUTDOOR UNIT KAE-26 DN7 KAE-35 DN7 KAE-52 DN7 KAE-71 DN7Compressor type Rotary Rotary Rotary Rotary

Outdoor airflow m3/h 1900 2000 2100 2700

Sound pressure dB (A) 55 56 58 61

Refrigerant R-410 R-410 R-410 R-410

Refrigerant charge / Supplementary charge ** gr 800/15 950/15 1480/15 2000/30

Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8")

Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") ø15.9 (5/8")

Max. piping length m 25 25 30 50

Pipe height difference m 10 10 20 25

Width/Height/Depth mm 770/555/300 800/554/333 800/554/333 845/702/363

Net weight Kg 26.6 29.1 37.8 48.4

Power wiring mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5

INDOOR UNIT KAY-S 26 DR7 KAY-S 35 DR7 KAY-S 52 DR7 KAY-S 71 DR7Airflow m3/h 515/459/337 515/459/337 750/505/420 1050/750/560

Sound pressure* dB (A) 21 23 21 26

Width/Height/Depth mm 802/297/189 802/297/189 965/319/215 1080/335/226

Net weight Kg 8.2 8.2 9 12

Power wiring mm2 From outdoor From outdoor From outdoor From outdoor

Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5

*Sound pressure in “Silence” mode.

**Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres.

Working temperature range: -15ºC to 50ºC (Cooling) / -20ºC to 30ºC (Heating)

BUSINESS GROUP

32

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

AUREA II R-32AUREA II, the medium-category range of KAYSUN UK, is characterized by its versatile nature: it can run on R-410A or R-32 refrigerant. In addition to a simple and elegant design, it incorporates all of KAYSUN’s most advanced characteristics and technologies.

• SCOP 4.0, over European Directive ERP, for a high energy efficiency.

• Louvres position memory.

• Leakage detection system.

• Drainage pipe connection from left or right option.

• Self-locking option for Heating-Only function.

• Display and buzzer switch-off to improve ambient comfort.

• White translucent smart DISPLAY with information on the equipment and alarm systems status.

• KID-02 S controller included to control unit's work parameters and change its configuration.

• Mono-Multi compatible.

• Easy installation optional WIFI control adding K03 WIFI USB

For further information, please see our Controllers rangeCONTROLLERS

BMS AND SOFTWARE

K01-WIFI

GENERAL CHARACTERISTICS

NEW

POSSIBILITY TO BLOCK THE UNIT FOR HEATING-ONLY +WIFI CONTROL (OPTIONAL)+

KID-02 SSTANDARD

OPTIONAL WIFI

K03 WIFI USB ACCESSORY

PRICE LIST

SET INDOOR UNIT OUTDOOR UNIT STANDARD CONTROL PRICE SET

KAY-S 26 DR7 KAY-S 26 DR7 KAE-26 DR7 KID-02 S £473

KAY-S 35 DR7 KAY-S 35 DR7 KAE-35 DR7 KID-02 S £507

KAY-S 52 DR7 KAY-S 52 DR7 KAE-52 DR7 KID-02 S £839

KAY-S 71 DR7 KAY-S 71 DR7 KAE-71 DR7 KID-02 S £1,053

ACCESSORIES

MODEL PRICE

K03 WIFI USB ACCESSORY £36

SETSRESIDENTIAL RANGE

33

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

TECHNICAL SPECIFICATIONS

SET KAY-S 26 DR7 KAY-S 35 DR7 KAY-S 52 DR7 KAY-S 71 DR7Cooling capacity (min./rated/max.) kW 1.08/2.64/3.46 1.11/3.52/4.51 1.73/5.28/6.21 2.58/7.33/8.44

Cooling capacity (min./rated/max.) Kcal/h 932/2268/2974 958/3024/3881 1487/4536/5342 2218/6300/7257

Cooling input (min./rated/max.) W 70/712/1240 70/1004/1610 120/1900/2390 230/2500/3370

SEER 8.2 7.5 6.7 6.9

Cooling energy class A++ A++ A++ A++

Heating capacity (min./rated/max.) kW 0.88/2.93/3.90 0.88/3.81/4.92 1.06/5.57/6.98 1.52/7.62/9.44

Heating capacity (min./rated/max.) Kcal/h 756/2520/3352 756/3276/4234 907/4788/5997 1310/6552/8114

Heating input (min./rated/max.) W 140/697/1300 140/1002/1640 190/1860/2490 230/2425/3370

SCOP 4.6 4.6 4.0 4.0

Heating efficiency class A++ A++ A+ A+

SCOP (warm areas) 5.6 5.2 5.1 5.1

Heating energy class (warm areas) A+++ A+++ A+++ A+++

Heating capacity -7ºC kW 2.10 2.28 3.85 4.85

COP -7ºC 2.8 2.75 2.77 2.44

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

OUTDOOR UNIT KAE-26 DR7 KAE-35 DR7 KAE-52 DR7 KAE-71 DR7Compressor type Rotary Rotary Rotary Rotary

Outdoor airflow m3/h 2000 2000 2100 2700

Sound pressure dB (A) 55 55 57 59

Refrigerant R-32 R-32 R-32 R-32

Refrigerant charge / Supplementary charge ** gr 650 / 12 650 / 12 1250 / 12 1600 / 24

Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8")

Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") ø15.9(5/8")

Max. piping length m 25 25 30 50

Pipe height difference m 10 10 20 25

Width/Height/Depth mm 800/554/333 800/554/333 800/554/333 845/700/320

Net weight Kg 37 37 37 48

Power wiring mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5

INDOOR UNIT KAY-S 26 DR7 KAY-S 35 DR7 KAY-S 52 DR7 KAY-S 71 DR7Air Flow m3/h 515/459/337 515/459/337 750/505/420 1050/750/560

Sound pressure* dB (A) 21 23 21 26

Width/Height/Depth mm 802/297/189 802/297/189 965/319/215 1080/335/226

Net weight Kg 8.2 8.2 9 12

Power wiring mm2 From outdoor From outdoor From outdoor From outdoor

Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5

*Sound pressure in “Silence” mode.

**Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres.

Working temperature range: -15ºC to 50ºC (Cooling) / -25ºC to 30ºC (Heating)

BUSINESS GROUP

34

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

ERP

ONNIX

K01-WIFI

CONTROLLERS

BMS AND SOFTWARE

Its original V-shape design, dark shade finishing and mirror-effect front side provide this unit with a very attractive modern appearance. The unit opens automatically when it switches on to increase airflow, and it closes when it switches off to recover its compact appearance.

• SCOP 4.0, over European Directive ERP, for a high energy efficiency.

• A brightness sensor regulates the display’s intensity.

• Louvres position memory.

• Leakage detection system.

• Drainage pipe connection from left or right option.

• Self-locking option for Heating-Only function.

• White translucent smart DISPLAY with information on the equipment and alarm systems status.

• KID-02 S controller included to control unit's work parameters and change its configuration.

• Mono-Multi compatible.

• Optional WIFI control adding K03 WIFI USB.

GENERAL CHARACTERISTICS

BRIGHTNESS SENSOR +

WIFI CONTROL (OPTIONAL) +

For further information, please see our Controllers range

KID-02 SSTANDARD

OPTIONAL WIFI

K03 WIFI USB ACCESSORY

PRICE LIST

SET INDOOR UNIT OUTDOOR UNIT STANDARD CONTROL PRICE SET

KAY-D 26 DN7 KAY-D 26 DN7 KAE-26 DN7 KID-02 S £498

KAY-D 35 DN7 KAY-D 35 DN7 KAE-35 DN7 KID-02 S £530

KAY-D 52 DN7 KAY-D 52 DN7 KAE-52 DN7 KID-02 S £883

ACCESSORIES

MODEL PRICE

K03 WIFI USB ACCESSORY £36

SETSRESIDENTIAL RANGE

35

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

* Sound pressure in “Silence” mode / **Factory pre-charge for 5 metres installation / Additional charge for every metre added after 5 metres.

Working temperature range: -15ºC to 50ºC (Cooling) / -20ºC to 30ºC (Heating)

TECHNICAL SPECIFICATIONS

SET KAY-D 26 DN7 KAY-D 35 DN7 KAY-D 52 DN7Cooling capacity (min./rated/max.) kW 1.23/2.64/3.30 1.33/3.52/4.47 1.83/5.28/6.12

Cooling capacity (min./rated/max.) Kcal/h 1057/2270/2838 1144/3027/3844 1574/4541/5263

Cooling input (min./rated/max.) W 100/712/1260 100/1095/1710 140/1643/2345

SEER 7.4 6.9 6.6

Cooling energy class A++ A++ A++

Heating capacity (min./rated/max.) kW 0.85/2.93/3.72 1.04/3.81/4.88 1.40/5.57/6.53

Heating capacity (min./rated/max.) Kcal/h 731/2520/3199 894/3276/4197 1204/4790/5616

Heating input (min./rated/max.) W 130/792/1320 160/1117/1730 212/1542/2390

SCOP 4.1 4.1 4.1

Heating efficiency class A+ A+ A+

SCOP (warm areas) 5.3 5.2 5.3

Heating energy class (warm areas) A+++ A+++ A+++

Heating capacity -7ºC kW 2.31 2.43 3.75

COP -7ºC 2.76 2.81 2.82

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50

INDOOR UNIT KAY-D 26 DN7 KAY-D 35 DN7 KAY-D 52 DN7Air Flow m3/h 400/300/240 500/350/270 710/620/480

Sound pressure* dB (A) 20 20 23

Width/Height/Depth mm 897/312/182 987/312/182 1004/350/205

Net weight Kg 9.5 9.9 13

Power wiring mm2 From outdoor From outdoor From outdoor

Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5

OUTDOOR UNIT KAE-26 DN7 KAE-35 DN7 KAE-52 DN7Compressor type Rotary Rotary Rotary

Outdoor airflow m3/h 1900 2000 2100

Sound pressure dB (A) 55 55 56

Refrigerant R-410 R-410 R-410

Refrigerant charge / Supplementary charge ** gr 800/15 950/15 1480/15

Liquid pipe diameter mm (Inch) Ø6.35 (1/4") Ø6.35 (1/4") Ø6.35 (1/4")

Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") Ø12.7 (1/2")

Max. piping length m 25 25 30

Pipe height difference m 10 10 20

Width/Height/Depth mm 770/550/300 800/554/333 800/554/333

Net weight Kg 26.6 29.1 37.8

Power wiring mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5

BUSINESS GROUP

36

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

DOUBLE FLOW CONSOLE

CONTROLLERS

The double flow console has an elegant and compact design that allows for the adaptation thereof to any area to be air-conditioned. It is fitted with the latest technological features, thereby providing users with a high comfort level.

• Double air supply

• Four air intakes

• Silent unit

• DC Inverter fan motor with 5 speeds.

• Voltage-free alarm and ON/OFF dry contacts.

• Optional wired controller.

K01-LON K01-BACNET K01-KNXKAYNET CONTROL K01-WIFI INDOOR XYE ON

BMS AND SOFTWARE ACCESORY

INDIVIDUAL

For further information, please see our Controllers range

CENTRALISED

KID-02 S KCT-02.1 SRKC-02.1 H KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB

KID-02 S(*) RECOMMENDED

GENERAL CHARACTERISTICS

ERP

K02-MODBUS

KC-01 S

(*) Price calculation based on the recommended controller.

PRICE LIST

SET INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE SET £

KSD-35 DVN10 KSD-35 DN6 KUE-35 DVN10 KID-02 S £790

KSD-52 DVN10 KSD-52 DMNU8 KAE-52 DN7 KID-02 S £953

SETSRESIDENTIAL RANGE

37

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

SET KSD-35 DVN10 KSD-52 DVN10Cooling capacity (min./rated/max.) kW 0.62/3.52/4.40 0.73/4.69/5.57

Cooling capacity (min./rated/max.) Kcal/h 533/3026/3783 630/4032/4788

Cooling input (min./rated/max.) W 211/1030/1690 240/1670/2200

SEER 6.1 5.3

Cooling energy class A++ A

Heating capacity (min./rated/max.) kW 0.62/3.81/4.95 0.82/5.00/6.30

Heating capacity (min./rated/max.) Kcal/h 533/3276/4256 705/4299/5417

Heating input (min./rated/max.) W 190/1000/1760 270/1550/2150

SCOP 4.0 3.8

Heating efficiency class A+ A

SCOP (warm areas) 5.1 4.6

Heating energy class (warm areas) A+++ A++

Heating capacity -7ºC kW 3.18 3.52

COP -7ºC 2.73 2.48

Power supply V / F / Hz 220-240/1/50 220-240/1/50

OUTDOOR UNIT KUE-35 DVN10 KAE-52 DN7Compressor type Rotary Rotary

Outdoor airflow m3/h 2000 2100

Sound pressure dB (A) 57 56

Refrigerant R-410 R-410

Refrigerant charge / Supplementary charge ** gr 1380 / 15 1480/15

Liquid pipe diameter mm (Inch) Ø6.35 (1/4") Ø6.35 (1/4")

Gas pipe diameter mm (Inch) Ø9.52 (3/8") Ø12.7 (1/2")

Max. piping length m 25 30

Pipe height difference m 10 20

Width/Height/Depth mm 800/554/333 800/554/333

Net weight Kg 34.5 37.8

Power wiring mm2 (2+T)x2.5 (2+T)x2.5

Communication wiring mm2 (3+T)x2.5 (4+T)x2.5

INDOOR UNIT KSD-35 DN6 KSD-52 DMNU8Air Flow m3/h 550/470/360 590/540/480

Sound pressure* dB (A) 35 35

Width/Height/Depth mm 700/600/210 700/600/210

Net weight Kg 15 15

Power wiring mm2 From outdoor From outdoor

Communication wiring mm2 (3+T)x2.5 (3+T)x2.5

*Sound pressure at low speed.

**Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres.

Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

TECHNICAL SPECIFICATIONS

BUSINESS GROUP

38

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

RESIDENTIAL PRODUCT RANGEMULTISYSTEM SUITE

“ELEGANCE AND COMFORT

FOR YOUR HOME”

Introducing the KAYSUN UK 2017 Multisystem DC Inverter designed to provide comfort and technology to every space. Available in R-410A and R-32. This is a flexible and versatile range that allows multiple combinations with different types of indoor units. This range is also affected by the European Directive ERP regarding equipment of less than 8 kW, with which is compliant thanks to the technological development of its components. All external units are fitted with a DC Inverter compressor and fan motor, while all internal units also have a DC Inverter fan motor.

These units are the solution for small spaces in which a larger scale installation is not possible. They allow for combinations containing up to 5 indoor units.

We have more or fewer combinations, depending on the gas refrigerant. With R-410 A, we can create combinations of different indoors: Wall-mounted (PRODIGY, ONNIX, AUREA II models), Cassette ArtFlux 360º, duct and double flow console with capacities from 2 to 7.1 kW. In R-32, for the time being we only have wall-mounted units (AUREA II) with capacities from 2.6 to 7.1 kW.

APP/WIFIKAYSUN UK has a plug&play WiFi control system. Thanks to our USB accessory, you can quickly and easily configure your split unit through your smartphone.

OUTDOOR UNITSThe residential product range has external units with a robust design designed to make maintenance easier and to protect its main components, so as to extend the useful life of the product.

WEEKLY TIMER+CHECK+BASIC FUNCTIONS+

K03 WIFI USB ACCESSORY

PLUG & PLAY+

ERP

R-32 AND R-410A REFRIGERANT+STRONGER+LOW SOUND LEVELS+

www.kaysun.co.uk

DOWNLOAD OUR APPLICATION FROM:

INTRODUCTION TO THE RANGE OF PRODUCTSRESIDENTIAL RANGE

39

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

SMART CONTROLLERSThe KAYSUN UK multisystem range has controls on the altitude, innovation and technology of units in the range. The cable and wireless controls have the most technologically-advanced functions and utilities, but with a modern and avant-garde aesthetic.

ADVANACED AESTHETIC+

WEEKLY TIMER

FOLLOW ME+

KC-03 SPS

INSTALLATION PARAMETRES MODIFICATION+OPERATION PARAMETERS CHECKING+FOLLOW ME

KID-02 S

DISTANCES AND HEIGHT DIFFERENCES

2X1 3X1 4X1 5X1

TOTAL LENGTH 40 60 80 80

MAXIMUM HEIGHT 15

MAXIMUM DISTANCEPER OUTPUT

25 30 35 35

+

+

BUSINESS GROUP

40

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

2.0 3.52.6 5.2 7.1POWER KW

DUCTS

KAY-26 DN7

KAY-S 26 DR7

KPD-26 DMN7KPD-20 DMN7

KCI-26 DMN7

KSD-26 DMN6

KAY-D 26 DN7

KAY-35 DN7

KAY-S 35 DR7

KPD-35 DN10

KCI-35 DN10

KSD-35 DN6

KAY-D 35 DN7

KAY-52 DN7

KAY-S 52 DR7

KPD-52 DMNU8

KCI-52 DMNU9

KSD-52 DMNU8

KAY-D 52 DN7

KAY-71 DN7

KAY-S 71 DR7

KPD-71 DMNU8

KCIS-71 DMNU9

PRODIGY

AUREA II

ONNIX

DOUBLE FLOW CONSOLE

CASSETTE

Nº OF INDOOR UNITS

2

3

4

5

4.2 6.25.2 7.8 8.0 10.5 12.0POWER KW

KAM3-78 DN7KAM3-62 DN7

KAM2-52 DN7KAM2-42 DN7

KAM4-80 DN7 KAM4-105 DN7

KAM5-120 DN7

R-410A MULTISYSTEM

INDOOR UNITS

OUTDOOR UNITS

NEW

INTRODUCTION TO THE RANGE OF PRODUCTSRESIDENTIAL RANGE

41

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

2.0 3.52.6 5.2 7.1POWER KW

KAY-S 26 DR7 KAY-S 35 DR7 KAY-S 52 DR7 KAY-S 71 DR7

AUREA II

Nº OF INDOOR UNITS

2

3

4

5

4.2 6.25.2 7.8 8.0 10.5 12.0POWER KW

KAM3-78 DR7

KAM2-52 DR7

KAM4-105 DR7

KAM5-120 DR7

R-32 MULTISYSTEM

INDOOR UNITS

OUTDOOR UNITS

NEW

NEW

BUSINESS GROUP

42

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

TECHNICAL SPECIFICATIONS

PRODIGY R-410A MULTISYSTEM

MODEL KAY-26 DN7 KAY-35 DN7 KAY-52 DN7 KAY-71 DN7Cooling capacity kW 2.64 3.52 5.28 7.03

Cooling capacity Kcal/h 2268 3024 4536 6048

Heating capacity kW 2.93 3.81 5.57 7.33

Heating capacity Kcal/h 2520 3276 4788 6300

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

Airflow m³/h 472/360/254 563/497/224 870/730/500 1176/921/446

Sound pressure* dB (A) 20 22 26 28

Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8")

Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") ø15.9(5/8")

Width/Height/Depth mm 717/302/193 805/302/193 964/325/222 1106/342/232

Net weight Kg 7 7.7 10.1 13.2

Power wiring mm2 From outdoor From outdoor From outdoor From outdoor

Communication wiring mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5

*Sound pressure in “Silence” mode.

INDOOR UNITSRESIDENTIAL RANGE

43

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

ERP

K01-WIFIKC-02.1 HKC-01 S

For further information, please see our Controllers range

INDIVIDUAL

CONTROLLERS

BMS AND SOFTWARE

GENERAL CHARACTERISTICS

PRODIGY is a KAYSUN UK wall unit that represents a revolution in installation and preventive maintenance*. Easy installation, maintenance and fitted with Kaysun avant-garde technology.

• Optional WIFI control adding K03 WIFI USB.

• Mono-Multi compatible.

• White translucent smart DISPLAY with information on the equipment and alarm systems status.

• The display and buzzer have a switch-off option which can be activated if they annoy the user.

• KID-02 S controller included to control unit's work parameters and change its configuration.

• Louvres position memory.

• Drainage pipe connection from left or right option.

• Compatible with wired controllers.

* For further information, please check the Presentation section of this manual.

KID-02 SSTANDARD

K03 WIFI USB ACCESSORY

KCT-02.1 SR

WIFI CONTROL (OPTIONAL)+

COMPATIBLE WITH

MULTISYSTEM OUTDOOR UNITS

see pag. 58

EASY ASSEMBLY AND MAINTENANCE +

OPTIONAL WIFI

PRICE LIST

MODEL STANDARD CONTROLLER PRICE

KAY-26 DN7 KID-02 S £110

KAY-35 DN7 KID-02 S £121

KAY-52 DN7 KID-02 S £182

KAY-71 DN7 KID-02 S £246

ACCESSORIES

MODEL PRICE

K03 WIFI USB ACCESSORY £36

BUSINESS GROUP

44

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

*Sound pressure in “Silence” mode.

AUREA II R-410A MULTISYSTEM

TECHNICAL SPECIFICATIONS

MODEL KAY-S 26 DR7 KAY-S 35 DR7 KAY-S 52 DR7 KAY-S 71 DR7

Cooling capacity kW 2.64 3.52 5.28 7.03

Cooling capacity Kcal/h 2268 3024 4536 6048

Heating capacity kW 2.93 3.81 5.57 7.64

Heating capacity Kcal/h 2520 3276 4788 6552

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

Airflow m3/h 515/459/337 515/459/337 750/505/420 1050/750/560

Sound pressure* dB (A) 21 23 21 26

Width/Height/Depth mm 802/297/189 802/297/189 965/319/215 1080/335/226

Net weight Kg 8.2 8.2 9 12

Power wiring mm2 From outdoor From outdoor From outdoor From outdoor

Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5

NEW

INDOOR UNITSRESIDENTIAL RANGE

45

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

ERP

BMS AND SOFTWARE

CONTROLS

K01-WIFI

GENERAL CHARACTERISTICS

AUREA II, the medium category range of KAYSUN UK, is characterised by its multi-use nature: it can run on R-410A or R-32 refrigerant. In addition to a simple and elegant design, it incorporates all of KAYSUN’s most advanced characteristics and technologies.

• Optional WIFI control adding K03 WIFI USB.

• Mono-Multi compatible.

• White translucent smart DISPLAY with information on the equipment and alarm systems status.

• The display and buzzer have a switch-off option which can be activated if they annoy the user.

• KID-02 S controller included to control unit's work parameters and change its configuration.

• Louvres position memory.

• Drainage pipe connection from left or right option.

WIFI CONTROL (OPTIONAL)+

21 dB SOUND PRESSURE+

K03 WIFI USB ACCESSORY

OPTIONAL WIFIKID-02 S

STANDARD

COMPATIBLE WITH

MULTISYSTEM OUTDOOR UNITS

see pag. 58

PRICE LIST

MODEL STANDARD CONTROLLER PRICE

KAY-S 26 DR7 KID-02 S £131

KAY-S 35 DR7 KID-02 S £139

KAY-S 52 DR7 KID-02 S £239

KAY-S 71 DR7 KID-02 S £277

ACCESSORIES

MODEL PRICE

K03 WIFI USB ACCESSORY £36

BUSINESS GROUP

46

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

*Sound pressure in “Silence” mode.

ONNIX R-410A MULTISYSTEM

TECHNICAL SPECIFICATIONS

MODEL KAY-D 26 DN7 KAY-D 35 DN7 KAY-D 52 DN7

Cooling capacity kW 2.64 3.52 5.28

Cooling capacity Kcal/h 2268 3024 4536

Heating capacity kW 2.93 3.81 5.57

Heating capacity Kcal/h 2520 3276 4788

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50

Airflow m3/h 400/300/240 500/350/270 740/620/480

Sound pressure* dB (A) 20 20 28

Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4")

Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2")

Width/Height/Depth mm 897/182/312 897/182/312 1004/205/350

Net weight Kg 9.5 9.9 13.0

Power wiring mm2 From outdoor From outdoor From outdoor

Communication wiring mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5

INDOOR UNITSRESIDENTIAL RANGE

47

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

ERP

KID-02 SSTANDARD

BMS AND SOFTWARE

CONTROLS

K01-WIFI

GENERAL CHARACTERISTICS

Onnix, the top-end range of KAYSUN UK in wall-mounted units. Its original V-shape design, dark shade finishing and mirror-effect front side provide this unit with a very attractive modern appearance. The unit opens automatically when it switches on to increase airflow and it closes when it switches off to recover its compact appearance.

• A brightness sensor regulates the display's intensity.

• KID-02 S controller included to control unit's work parameters and change its configuration.

• Louvres position memory.

• Optional WIFI control adding K03 WIFI USB.

• Mono-Multi compatible.

• Drainage pipe connection from left or right option.

K03 WIFI USB ACCESSORY

WIFI CONTROL (OPTIONAL)+

20 dB SOUND PRESSURE+

OPTIONAL WIFI

COMPATIBLE WITH

MULTISYSTEM OUTDOOR UNITS

see pag. 58

PRICE LIST

MODEL STANDARD CONTROLLER PRICE

KAY-D 26 DN7 KID-02 S £218

KAY-D 35 DN7 KID-02 S £237

KAY-D 52 DN7 KID-02 S £309

ACCESSORIES

MODEL PRICE

K03 WIFI USB ACCESSORY £36

BUSINESS GROUP

48

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

MODEL KSD-26 DMN6 KSD-35 DN6 KSD-52 DMNU8

Cooling capacity kW 2.64 3.46 5.28

Cooling capacity Kcal/h 2270 2976 4536

Heating capacity kW 2.93 3.46 5.57

Heating capacity Kcal/h 2520 2976 4788

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50

Airflow m³/h 680/580/450 550/470/360 740/650/520

Sound pressure* dB (A) 35 36 39

Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4")

Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2")

Width/Height/Depth mm 700/600/210 700/600/210 700/600/210

Net weight Kg 13.5 15 15

Power wiring mm2 From outdoor From outdoor From outdoor

Communication wiring mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5

*Sound pressure data at low speed.

DOUBLE FLOW CONSOLE R-410A MULTISYSTEM

TECHNICAL SPECIFICATIONS

INDOOR UNITSRESIDENTIAL RANGE

49

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

The double flow console has an elegant and compact design that allows for the adaptation thereof to any area to be air-conditioned. This unit has the best technological features and its adaptability cover the needs of every user.

• DC Inverter fan MOTOR.

• Double air supply and four air intakes.

• Voltage-free alarm and ON/OFF dry contacts.

• Easy installation.

• Optional wired controller.

UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, add to the € price for the set the price difference

between the recommended controller and the selected controller.

ELIGE TU CONTROL

ERP

KC-01 S KCC-16

CENTRALISED

KCCT-64 I

INDIVIDUAL

BMS AND SOFTWARE

K01-LON K01-BACNET KAYNET CONTROL

KCC-64 I-PS

K01-KNX K01-WIFI

CONTROLS

GENERAL CHARACTERISTICS

DOUBLE AIR INTAKE +

RECOMMENDED

KID-02 S

KCT-02.1 SRKID-02 S KCC-64 WEB

For further information, please see our Controllers range

K02-MODBUS

KC-02.1 H

Enquire about availability and price.

CHOOSE YOUR CONTROL

COMPATIBLE WITH

MULTISYSTEM OUTDOOR UNITS

see pag. 58

PRICE LIST

MODEL RECOMMENDED CONTROLLER PRICE

KSD-26 DMN6 KID-02 S £247

KSD-35 DN9 KID-02 S £275

KSD-52 DMNU8 KID-02 S £303

(*) Price calculation based on the recommended controller.

BUSINESS GROUP

50

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

MODEL KCI-26 DMN8 KCI-35 DN10 KCI-52 DMNU9 KCIS-71 DMNU9

Cooling capacity kW 2.64 3.52 4.98 7.03

Cooling capacity Kcal/h 2268 3024 4284 6048

Heating capacity kW 2.93 4.1 5.57 7.33

Heating capacity Kcal/h 2520 3528 4788 6300

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

Airflow m3/h 580/500/450 650/530/450 680/560/500 1520/1350/1200

Sound pressure* dB (A) 33.5 34 41 43

Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8")

Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") ø15.9 (5/8")

Width/Height/Depth mm 570/260/570 570/260/570 570/260/570 840/245/840

Net weight Kg 14.5 16 16.1 24.0

Panel width/height/depth mm 647/50/647 647/50/647 647/50/647 950/55/950

Panel net weight Kg 2.5 2.5 2.5 5.0

Power wiring mm2 From outdoor From outdoor From outdoor From outdoor

Communication wiring mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5

CASSETTE ART FLUX 360º R-410A MULTISYSTEM

TECHNICAL SPECIFICATIONS

*Sound pressure at low speed.

INDOOR UNITSRESIDENTIAL RANGE

51

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

Cassette Art Flux 360º units have an impeccable design. Its 360º airflow provides user with maximum comfort covering every single corner of the room.

• They are fitted with an up to 500 mm high standard condensation pump.

• Voltage-free alarm and ON/OFF dry contacts.

• The right and left sides of these units' body are designed to connect the necessary piping to air-condition an adjacent room.

• The units supply 10 % to 15 % of outdoor airflow directly to the unit return system.

• The electric box is located at the lower side of the unit to get a more compact size and embeds the unit easily in the ceiling.

ERP

CENTRALISEDINDIVIDUAL

BMS AND SOFTWARE

For further information, please see our Controllers rangeCONTROLS

GENERAL CHARACTERISTICS

KCC-16KCCT-64 I KCC-64 I-PS KCC-64 WEB

K01-LON K01-BACNET KAYNET CONTROL K01-KNX K01-WIFI

RECOMMENDED

KID-02 S

KID-02 S

K02-MODBUS

KC-03 SPS

500mm CONDENSATION PUMP +

OUTDOOR AIR SUPPLY (10-15%)+

UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you shall add to the € price for the set, the price

difference between the recommended controller and the selected controller.ELIGE TU CONTROL

CHOOSE YOUR CONTROL

COMPATIBLE WITH

MULTISYSTEM OUTDOOR UNITS

see pag. 58

PRICE LIST

MODEL RECOMMENDED CONTROLLER PRICE

KCI-26 DMN8 KID-02 S £427

KCI-35 DN10 KID-02 S £458

KCI-52 DMNU9 KID-02 S £532

KCIS-71 DMNU9 KID-02 S £650

(*) Price calculation based on the recommended controller.

BUSINESS GROUP

52

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

33

DUCTS R-410A MULTISYSTEM

TECHNICAL SPECIFICATIONS

MODEL KPD-20 DMN7 KPD-26 DMN7 KPD-35 DN10 KPD-52 DMNU8 KPD-71 DMNU8

Cooling capacity kW 2.05 2.64 3.52 4.98 7.03

Cooling capacity Kcal/h 1764 2268 3024 4284 6048

Heating capacity kW 2.34 2.93 3.81 5.57 7.33

Heating capacity Kcal/h 2016 2520 3276 4788 6300

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

Airflow m3/h 530/400/340 530/400/340 680/580/450 858/728/623 1510/1280/1090

Static (rated) pressure range Pa 0-40(25) 0-40(25) 0-40(25) 0-60(25) 0-80(25)

Sound pressure* dB (A) 30.9 28.0 35.0 30.0 37.0

Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8")

Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") ø15.9 (5/8")

Width/Height/Depth mm 700/210/635 700/210/635 700/210/635 920/210/635 920/270/635

Net weight Kg 18.5 18.5 18.5 23 28

Power wiring mm2 From outdoor From outdoor From outdoor From outdoor From outdoor

Communication wiring mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5

*Sound pressure at low speed.

INDOOR UNITSRESIDENTIAL RANGE

53

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

The tilted evaporator of the KAYSUN UK Ducts provides them with a very slim design. This feature allows for installing Ducts units in areas where the false ceiling is too narrow.

• The filter is easy to remove even when piping is in place.

• All units include an air inlet/outlet frames to facilitate the fitting of the air ducts.

• The units have the possibility to make an outdoor air intake directly to the unit.

• The electric box of Duct type indoor units is removable up to 1 metre.

• They are fitted with an up to 500 mm high standard condensation pump.

• Voltage-free alarm and ON/OFF dry contacts.

Compatible con

KC-03 SPSRECOMMENDED

ERP

KCC-16KCCT-64 I

CENTRALISEDINDIVIDUAL

BMS AND SOFTWARE

K01-LON K01-BACNET KAYNET CONTROL

KCC-64 I-PS

K01-KNXK01-WIFI

For further information, please see our Controllers rangeCONTROLS

GENERAL CHARACTERISTICS

750mm CONDENSATION PUMP +

OUTDOOR AIR INTAKE+

KC-02.1 HKCT-02.1 SRKCC-64 WEB

KC-03 SPS

K02-MODBUS

KID-02 S KC-01 S

UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you shall add to the € price for the set, the price

difference between the recommended controller and the selected controller.ELIGE TU CONTROL

CHOOSE YOUR CONTROL

COMPATIBLE WITH

MULTISYSTEM OUTDOOR UNITS

see pag. 58

PRICE LIST

MODEL RECOMMENDED CONTROL PRICE

KPD-20 DMN7 KC-03 SPS £329

KPD-26 DMN7 KC-03 SPS £332

KPD-35 DN10 KC-03 SPS £346

KPD-52 DMNU8 KC-03 SPS £353

KPD-71 DMNU8 KC-03 SPS £375

(*) Price calculation based on the recommended controller.

BUSINESS GROUP

54

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

DUCT R-410A MULTISYSTEM

STATIC PRESSURE GRAPHS

KPD-20 DMN7

KPD-26 DMN7

KPD-35 DN10

STATIC PRESSURE GRAPHSRESIDENTIAL RANGE

55

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

KPD-52 DMNU8

KPD-71 DMNU8

BUSINESS GROUP

56

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

Note: Standard performance data; definitive performance data depend on the combination of indoor units.

MODEL KAM2-42 DN7 KAM2-52 DN7 KAM3-62 DN7 KAM3-78 DN7Cooling capacity kW 4.10 5.28 6.15 7.91

Cooling capacity Kcal/h 3526 4536 5292 6804

Cooling input kW 1.25 1.60 1.91 2.46

Heating capacity kW 4.40 5.57 6.59 8.21

Heating capacity Kcal/h 3784 4788 5670 7056

Heating input kW 1.15 1.59 1.78 2.27

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

Compressor type Rotary Rotary Rotary Rotary

Outdoor airflow m3/h 2100 2100 2700 3500

Sound pressure dB (A) 54 58 55 58

Refrigerant R-410 A R-410 A R-410 A R-410 A

Additional refrigerant charge* gr 1250 1700 2100 2100

Pre-charge metres* m 10 10 15 15

Liquid pipe diameter mm (Inch) ø6.35 (1/4") x 2 ø6.35 (1/4") x 2 ø6.35 (1/4") x 3 ø6.35 (1/4") x 3

Gas pipe diameter mm (Inch) ø9.52 (3/8") x 2 ø9.52 (3/8") x 2 ø9.52 (3/8") x 3 ø9.52 (3/8") x 3

Piping max. length m 40 40 60 60

Piping max. length (1 indoor unit) m 25 25 30 30Height difference between indoor and outdoor units

m 15 15 15 15

Height difference between indoor units m 10 10 10 10

Width/Height/Depth mm 800/554/333 800/554/333 845/702/363 845/702/363

Net weight Kg 30.5 30.5 47.0 52.7

Maximum number of indoor units 2 2 3 3

Power wiring mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x4

Communication wiring mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5

OUTDOOR UNITS

TECHNICAL SPECIFICATIONS

*To calculate the additional load necessary for these units, we applied the following formula:

ADDITIONAL LOAD (GR) = (TOTAL LENGTH OF ALL CIRCUITS' LIQUID LINE OF ¼” x 15 Grams) + (TOTAL LENGTH OF LIQUID LINE OF 3/8”

x 30 Grams) - (TOTAL LENGTH OF FACTORY PRELOAD CHARGE x 15 Grams).

ERP

KAYSUN UK MULTISYSTEM outdoor units, with their new appearance and stronger structure, provide greater output with less noise pollution.

QUIET+

STRONG +

R-410A MULTISYSTEM

RESIDENTIAL RANGE OUTDOOR UNIT

57

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

KAM4-80 DN7 KAM4-105 DN7 KAM5-120 DN78.21 10.55 12.31

7056 9072 10584

2.55 3.62 3.82

8.79 11.14 12.60

7560 9576 10836

2.43 3.17 3.31

220-240/1/50 220-240/1/50 220-240/1/50

Rotary Rotary Rotary

3800 5500 5500

55 58 58

R-410 A R-410 A R-410 A

2400 3000 3600

20 20 25

ø6.35 (1/4") x 4 ø6.35 (1/4") x 4 ø6.35 (1/4") x 5

ø9.52 (3/8”) x 3 + ø12.7 (1/2”) x 1 ø9.52 (3/8") x 3 + ø12.7 (1/2") x 1 ø9.52 (3/8") x 3 + ø12.7 (1/2") x 2

80 80 80

35 35 35

15 15 15

10 10 10

946/810/410 946/810/410 946/810/410

67.6 70.0 76.0

4 4 5

(2+T)x4 (2+T)x6 (2+T)x6

(3+T)x2.5 (3+T)x2.5 (3+T)x2.5

PRICE LIST

MODEL PRICE

KAM2-42 DN7 £665

KAM2-52 DN7 £793

KAM3-62 DN7 £968

KAM3-78 DN7 £1,124

KAM4-80 DN7 £1,243

KAM4-105 DN7 £1,543

KAM5-120 DN7 £1,843

BUSINESS GROUP

58

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

KAM2-42 DN7

20 20+20

26 20+26

35 20+35

52 26+26

26+35

x1 x2

COMBINED SYSTEMS

KAM2-52 DN7

20 20+20

26 20+26

35 20+35

52 20+52

26+26

26+35

26+52

35+35

x1 x2

R-410A MULTISYSTEM

RESIDENTIAL RANGE COMBINED SYSTEMS

59

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

COMBINATIONS RATED POWER (kW) COOLING CAPACITY (kW) INPUT POWER (kW)EER

(W/W)SEER ENERGY CLASS

1x2

UNIT A

UNIT B

UNIT A

UNIT B

MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY

20 20 2.05 2.05 1.76 4.10 4.54 0.42 1.24 1.43 3.30 6.10 A++

20 26 1.79 2.31 1.76 4.10 4.54 0.42 1.24 1.43 3.30 6.10 A++

20 35 1.51 2.59 1.76 4.10 4.54 0.42 1.23 1.43 3.32 6.10 A++

26 26 2.05 2.05 1.76 4.10 4.54 0.42 1.24 1.43 3.30 6.10 A++

26 35 1.76 2.34 1.76 4.10 4.54 0.42 1.23 1.43 3.32 6.10 A++

COMBINATIONS RATED POWER (kW) HEATING POWER (kW) INPUT POWER (kW)COP

(W/W)SCOP

ENERGY CLASS

COP -7

1x2

UNIT A

UNIT B

UNIT A

UNIT B

MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUMRATED

CAPACITY

20 20 2.20 2.20 1.89 4.40 4.87 0.39 1.16 1.33 3.80 4.00 A+ 3.15

20 26 1.93 2.48 1.89 4.40 4.87 0.39 1.16 1.33 3.80 4.00 A+ 3.15

20 35 1.66 2.84 1.89 4.50 4.98 0.39 1.19 1.33 3.78 4.00 A+ 3.13

26 26 2.20 2.20 1.89 4.40 4.87 0.39 1.16 1.33 3.80 4.00 A+ 3.15

26 35 1.93 2.57 1.89 4.50 4.98 0.39 1.19 1.33 3.78 4.00 A+ 3.13

COMBINATIONS RATED POWER (kW) COOLING CAPACITY (kW) INPUT POWER (kW)EER

(W/W)SEER ENERGY CLASS

1x2

UNIT A

UNIT B

UNIT A

UNIT B

MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUMRATED

CAPACITY

20 20 2.10 2.10 2.08 4.20 5.51 0.59 1.27 2.16 3.31 6.20 A++

20 26 2.06 2.64 2.08 4.70 5.72 0.59 1.46 2.16 3.23 6.20 A++

20 35 1.95 3.35 2.08 5.30 6.29 0.59 1.82 2.16 2.91 6.10 A++

20 52 1.51 3.92 2.08 5.40 6.34 0.59 1.77 2.16 3.05 6.10 A++

26 26 2.60 2.60 2.08 5.20 6.29 0.59 1.79 2.16 2.91 6.30 A++

26 35 2.31 3.09 2.08 5.40 6.29 0.59 1.83 2.16 2.95 6.30 A++

26 52 1.80 3.60 2.08 5.40 6.34 0.59 1.77 2.16 3.05 6.30 A++

35 35 2.70 2.70 2.08 5.40 6.29 0.59 1.79 2.16 3.01 6.30 A++

COMBINATIONS RATED POWER (kW) HEATING POWER (kW) INPUT POWER (kW)COP

(W/W)SCOP ENERGY CLASS COP -7

1x2

UNIT A

UNIT B

UNIT A

UNIT B

MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUMRATED

CAPACITY

20 20 2.50 2.50 2.20 5.00 5.94 0.50 1.30 1.85 3.85 4.00 A+ 3.19

20 26 2.32 2.98 2.20 5.30 6.05 0.50 1.39 1.85 3.81 4.00 A+ 3.16

20 35 2.03 3.47 2.20 5.50 6.66 0.50 1.48 1.85 3.71 4.00 A+ 3.07

20 52 1.57 4.07 2.20 5.60 6.71 0.50 1.47 1.85 3.81 4.00 A+ 3.16

26 26 2.75 2.75 2.20 5.50 6.66 0.50 1.48 1.85 3.71 4.00 A+ 3.07

26 35 2.40 3.20 2.20 5.60 6.66 0.50 1.49 1.85 3.75 4.00 A+ 3.11

26 52 1.87 3.73 2.20 5.60 6.71 0.50 1.47 1.85 3.81 4.00 A+ 3.16

35 35 2.80 2.80 2.20 5.60 6.66 0.50 1.49 1.85 3.75 4.00 A+ 3.11

BUSINESS GROUP

60

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

KAM3-62 DN7

20 20+20 20+20+20

26 20+26 20+20+26

35 20+35 20+20+35

52 20+52 20+26+26

26+26 20+26+35

26+35 26+26+26

26+52 26+26+35

35+35

KAM3-78 DN7

20 20+20 20+20+20

26 20+26 20+20+26

35 20+35 20+20+35

52 20+52 20+20+52

26+26 20+26+26

26+35 20+26+35

26+52 20+26+52

35+35 20+35+35

35+52 26+26+26

26+26+35

26+35+35

35+35+35

x1

x1

x2

x2

x3

x3

COMBINED SYSTEMS R-410A MULTISYSTEM

RESIDENTIAL RANGE COMBINED SYSTEMS

61

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

COMBINATIONS RATED POWER (kW) COOLING CAPACITY (kW) INPUT POWER (kW)EER

(W/W)SEER ENERGY CLASS

1x3

UNIT A UNIT B UNIT C UNIT A UNIT B UNIT C MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY

20 20 20 2.03 2.03 2.03 2.44 6.10 7.20 0.68 1.90 2.38 3.21 6.10 A++

20 20 26 1.92 1.92 2.47 2.44 6.30 7.26 0.68 1.96 2.38 3.22 6.10 A++

20 20 35 1.70 1.70 2.91 2.44 6.30 7.32 0.68 1.94 2.38 3.24 6.10 A++

20 26 26 1.76 2.27 2.27 2.44 6.30 7.32 0.68 1.94 2.38 3.24 6.10 A++

20 26 35 1.58 2.03 2.70 2.44 6.30 7.32 0.68 1.94 2.38 3.24 6.10 A++

26 26 26 2.10 2.10 2.10 2.44 6.30 7.32 0.68 1.94 2.38 3.24 6.10 A++

26 26 35 1.89 1.89 2.52 2.44 6.30 7.32 0.68 1.94 2.38 3.24 6.10 A++

COMBINATIONS RATED POWER (kW) COOLING CAPACITY (kW) INPUT POWER (kW)EER

(W/W)SEER ENERGY CLASS

1x3

UNIT A UNIT B UNIT C UNIT A UNIT B UNIT C MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY

20 20 20 2.43 2.43 2.43 2.77 7.30 8.69 0.76 2.27 2.93 3.21 6.60 A++

20 20 26 2.25 2.25 2.90 2.77 7.40 8.69 0.76 2.31 2.93 3.21 6.60 A++

20 20 35 2.13 2.13 3.65 2.77 7.90 8.69 0.76 2.46 2.93 3.21 6.60 A++

20 20 52 1.73 1.73 4.44 2.77 7.90 8.69 0.76 2.44 2.93 3.24 6.60 A++

20 26 26 2.13 2.74 2.74 2.77 7.60 8.69 0.76 2.37 2.93 3.21 6.60 A++

20 26 35 1.98 2.54 3.39 2.77 7.90 8.69 0.76 2.46 2.93 3.21 6.60 A++

20 26 52 1.63 2.09 4.18 2.77 7.90 8.69 0.76 2.44 2.93 3.24 6.60 A++

20 35 35 1.78 3.06 3.06 2.77 7.90 8.69 0.76 2.45 2.93 3.23 6.60 A++

26 26 26 2.63 2.63 2.63 2.77 7.90 8.69 0.76 2.46 2.93 3.21 6.60 A++

26 26 35 2.37 2.37 3.16 2.77 7.90 8.69 0.76 2.45 2.93 3.23 6.60 A++

26 35 35 2.15 2.87 2.87 2.77 7.90 8.69 0.76 2.44 2.93 3.24 6.60 A++

35 35 35 2.63 2.63 2.63 2.77 7.90 8.69 0.76 2.44 2.93 3.24 6.60 A++

COMBINATIONS RATED POWER (kW) HEATING POWER (kW) INPUT POWER (kW)COP

(W/W)SCOP

ENERGY CLASS

COP -7

1x3

UNIT A UNIT B UNIT C UNIT A UNIT B UNIT C MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUMRATED

CAPACITY

20 20 20 2.20 2.20 2.20 2.64 6.60 7.79 0.64 1.78 2.22 3.71 4.00 A+ 2.90

20 20 26 2.02 2.02 2.60 2.64 6.65 7.79 0.64 1.79 2.22 3.71 4.00 A+ 2.90

20 20 35 1.80 1.80 3.09 2.64 6.70 7.92 0.64 1.81 2.22 3.71 4.00 A+ 2.95

20 26 26 1.88 2.41 2.41 2.64 6.70 7.92 0.64 1.81 2.22 3.71 4.00 A+ 2.95

20 26 35 1.68 2.15 2.87 2.64 6.70 7.92 0.64 1.81 2.22 3.71 4.00 A+ 2.95

26 26 26 2.23 2.23 2.23 2.64 6.70 7.92 0.64 1.81 2.22 3.71 4.00 A+ 2.95

26 26 35 2.01 2.01 2.68 2.64 6.70 7.92 0.64 1.81 2.22 3.71 4.00 A+ 2.95

COMBINATIONS RATED POWER (kW) HEATING POWER (kW) INPUT POWER (kW)COP

(W/W)SCOP

ENERGY CLASS

COP -7

1x3

UNIT A UNIT B UNIT C UNIT A UNIT B UNIT C MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY

20 20 20 2.27 2.27 2.27 2.87 6.80 9.02 0.70 1.88 2.70 3.61 4.00 A+ 2.99

20 20 26 2.13 2.13 2.74 2.87 7.00 9.02 0.70 1.94 2.70 3.61 4.00 A+ 2.99

20 20 35 2.13 2.13 3.65 2.87 7.90 9.02 0.70 2.19 2.70 3.61 4.00 A+ 2.99

20 20 52 1.82 1.82 4.67 2.87 8.30 9.02 0.70 2.27 2.70 3.65 4.00 A+ 3.02

20 26 26 2.21 2.84 2.84 2.87 7.90 9.02 0.70 2.19 2.70 3.61 4.00 A+ 2.99

20 26 35 2.05 2.64 3.51 2.87 8.20 9.02 0.70 2.27 2.70 3.61 4.00 A+ 2.99

20 26 52 1.71 2.20 4.39 2.87 8.30 9.02 0.70 2.27 2.70 3.65 4.00 A+ 3.02

20 35 35 1.87 3.21 3.21 2.87 8.30 9.02 0.70 2.29 2.70 3.62 4.00 A+ 3.00

26 26 26 2.73 2.73 2.73 2.87 8.20 9.02 0.70 2.27 2.70 3.61 4.00 A+ 2.99

26 26 35 2.49 2.49 3.32 2.87 8.30 9.02 0.70 2.29 2.70 3.62 4.00 A+ 3.00

26 35 35 2.26 3.02 3.02 2.87 8.30 9.02 0.70 2.27 2.70 3.65 4.00 A+ 3.02

35 35 35 2.77 2.77 2.77 2.87 8.30 9.02 0.70 2.27 2.70 3.65 4.00 A+ 3.02

BUSINESS GROUP

62

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

KAM4-80 DN7

20 20+20 20+20+20 20+20+20+20

26 20+26 20+20+26 20+20+20+26

35 20+35 20+20+35 20+20+20+35

52 20+52 20+20+52 20+20+20+52

71 20+71 20+20+71 20+20+26+26

26+26 20+26+26 20+20+26+35

26+35 20+26+35 20+20+35+35

26+52 20+26+52 20+26+26+26

26+71 20+35+35 20+26+26+35

35+35 20+35+52 20+26+35+35

35+52 26+26+26 26+26+26+26

35+71 26+26+35 26+26+26+35

52+52 26+26+52

26+35+35

26+35+52

35+35+35

x1 x2 x3 x4

COMBINED SYSTEMS R-410A MULTISYSTEM

RESIDENTIAL RANGE COMBINED SYSTEMS

63

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

1x4

UNIT AUNIT

BUNIT

CUNIT

UNIT A

UNIT B

UNIT C

UNIT D

MIN. RATED MAX. MIN. RATED MAX. RATED CAPACITY

20 20 20 20 2.05 2.05 2.05 2.05 3.04 8.21 9.93 0.84 2.47 3.09 3.32 6.8 A++

20 20 20 26 1.92 1.92 1.92 2.46 3.04 8.21 9.93 0.84 2.47 3.09 3.32 6.8 A++

20 20 20 35 1.74 1.74 1.74 2.99 3.04 8.21 9.93 0.84 2.47 3.09 3.32 6.8 A++

20 20 20 52 1.47 1.47 1.47 3.79 3.04 8.21 9.93 0.84 2.50 3.09 3.28 6.8 A++

20 20 26 26 1.80 1.80 2.31 2.31 3.04 8.21 9.93 0.84 2.47 3.09 3.32 6.8 A++

20 20 26 35 1.64 1.64 2.11 2.81 3.04 8.21 9.93 0.84 2.49 3.09 3.30 6.8 A++

20 20 35 35 1.51 1.51 2.59 2.59 3.04 8.21 9.93 0.84 2.50 3.09 3.29 6.8 A++

20 26 26 26 1.69 2.17 2.17 2.17 3.04 8.21 9.93 0.84 2.48 3.09 3.31 6.8 A++

20 26 26 35 1.55 2.00 2.00 2.66 3.04 8.21 9.93 0.84 2.50 3.09 3.29 6.8 A++

20 26 35 35 1.44 1.85 2.46 2.46 3.04 8.21 9.93 0.84 2.50 3.09 3.28 6.8 A++

26 26 26 26 2.05 2.05 2.05 2.05 3.04 8.21 9.93 0.84 2.50 3.09 3.29 6.8 A++

26 26 26 35 1.89 1.89 1.89 2.53 3.04 8.21 9.93 0.84 2.50 3.09 3.28 6.8 A++

1x4

UNIT AUNIT

BUNIT

CUNIT

UNIT A

UNIT B

UNIT C

UNIT D

MIN. RATED MAX. MIN. RATED MAX. RATED CAPACITY

20 20 20 20 2.20 2.20 2.20 2.20 3.26 8.80 10.65 0.83 2.44 3.05 3.61 4.0 A++ 2.99

20 20 20 26 2.08 2.08 2.08 2.67 3.26 8.90 10.65 0.83 2.47 3.05 3.61 4.0 A++ 2.99

20 20 20 35 1.91 1.91 1.91 3.27 3.26 9.00 10.65 0.83 2.49 3.05 3.61 4.0 A++ 2.99

20 20 20 52 1.63 1.63 1.63 4.20 3.26 9.10 10.65 0.83 2.52 3.05 3.61 4.0 A++ 2.99

20 20 26 26 1.95 1.95 2.50 2.50 3.26 8.90 10.65 0.83 2.47 3.05 3.61 4.0 A++ 2.99

20 20 26 35 1.80 1.80 2.31 3.09 3.26 9.00 10.65 0.83 2.49 3.05 3.61 4.0 A++ 2.99

20 20 35 35 1.68 1.68 2.87 2.87 3.26 9.10 10.65 0.83 2.52 3.05 3.61 4.0 A++ 2.99

20 26 26 26 1.83 2.36 2.36 2.36 3.26 8.90 10.65 0.83 2.47 3.05 3.61 4.0 A++ 2.99

20 26 26 35 1.70 2.19 2.19 2.92 3.26 9.00 10.65 0.83 2.49 3.05 3.61 4.0 A++ 2.99

20 26 35 35 1.59 2.05 2.73 2.73 3.26 9.10 10.65 0.83 2.52 3.05 3.61 4.0 A++ 2.99

26 26 26 26 2.23 2.23 2.23 2.23 3.26 8.90 10.65 0.83 2.47 3.05 3.61 4.0 A++ 2.99

26 26 26 35 2.10 2.10 2.10 2.80 3.26 9.10 10.65 0.83 2.52 3.05 3.61 4.0 A++ 2.99

RATED CAPACITY (KW)

RATED CAPACITY (KW)

COOLING CAPACITY (KW)

HEATING CAPACITY (KW)

EERW/W

COPW/W

SEER

SCOP COP -7

ENERGY CLASS

ENERGY CLASS

INPUT POWER (kW)

INPUT POWER (kW)

COMBINATIONS

COMBINATIONS

BUSINESS GROUP

64

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

KAM4-105 DN7

20 20 +20 20 +20 +20 20 +20 +20 +20

26 20 +26 20 +20 +26 20 +20 +20 +26

35 20 +35 20 +20 +35 20 +20 +20 +35

52 20 +52 20 +20 +52 20 +20 +20 +52

71 20 +71 20 +20 +71 20 +20 +20 +71

26+26 20 +26 +26 20 +20 +26 +26

26+35 20 +26 +35 20 +20 +26 +35

26+52 20 +26 +52 20 +20 +26 +52

26+71 20 +26 +71 20 +20 +26 +71

35+35 20 +35 +35 20 +20 +35 +35

35+52 20 +35 +52 20 +20 +35 +52

35+71 20 +35 +71 20 +20 +52 +52

52+52 20 +52 +52 20 +26+26+26

26+26+26 20 +26+26+35

26+26+35 20 +26+26+52

26+26+52 20 +26+26+71

26+35+35 20 +26+35+35

26+35+52 20 +26+35+52

26+35+71 20 +26+52+52

26+52+52 20 +35+35+35

35+35+35 20 +35+35+52

35+35+52 26+26+26+26

35+35+71 26+26+26+35

35+52+52 26+26+26+52

26+26+35+35

26+26+35+52

26+35+35+35

26+35+35+52

35+35+35+35

x1 x2 x3 x4

COMBINED SYSTEMS R-410A MULTISYSTEM

RESIDENTIAL RANGE COMBINED SYSTEMS

65

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

COMBINATIONS RATED CAPACITY (KW); COOLING CAPACITY (KW) INPUT POWER (KW)EER

(W/W)SEER

ENERGY CLASS

UNIT A

UNIT B

UNIT C

UNIT D

UNIT A

UNIT B

UNIT C

UNIT D

MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY

1x4

20 20 20 20 2.05 2.05 2.05 2.05 3.71 8.20 10.60 0.89 2.30 3.30 3.56 7.6 A++

20 20 20 26 1.98 1.98 1.98 2.55 3.71 8.50 11.66 0.89 2.50 3.47 3.40 7.6 A++

20 20 20 35 2.02 2.02 2.02 3.45 3.71 9.50 12.72 0.89 2.88 3.63 3.30 7.6 A++

20 20 20 52 1.88 1.88 1.88 4.85 3.71 10.50 13.78 0.89 3.27 4.29 3.21 7.4 A++

20 20 20 71 1.65 1.65 1.65 5.65 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.4 A++

20 20 26 26 1.97 1.97 2.53 2.53 3.71 9.00 12.72 0.89 2.73 3.63 3.30 7.6 A++

20 20 26 35 2.00 2.00 2.57 3.43 3.71 10.00 13.25 0.89 3.12 3.96 3.21 7.6 A++

20 20 26 52 1.79 1.79 2.30 4.61 3.71 10.50 13.78 0.89 3.27 4.29 3.21 7.6 A++

20 20 26 71 1.58 1.58 2.03 5.41 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++

20 20 35 35 1.93 1.93 3.32 3.32 3.71 10.50 13.78 0.89 3.27 4.29 3.21 7.6 A++

20 20 35 52 1.67 1.67 2.86 4.30 3.71 10.50 13.78 0.89 3.27 4.29 3.21 7.6 A++

20 20 52 52 1.47 1.47 3.78 3.78 3.71 10.50 13.78 0.89 3.27 4.29 3.21 7.4 A++

20 26 26 26 1.96 2.51 2.51 2.51 3.71 9.50 13.25 0.89 2.94 3.80 3.23 7.6 A++

20 26 26 35 2.01 2.58 2.58 3.44 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++

20 26 26 52 1.73 2.22 2.22 4.44 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++

20 26 26 71 1.51 1.95 1.95 5.19 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++

20 26 35 35 1.86 2.39 3.18 3.18 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++

20 26 35 52 1.61 2.07 2.77 4.15 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++

20 26 52 52 1.43 1.83 3.67 3.67 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++

20 35 35 35 1.73 2.96 2.96 2.96 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++

20 35 35 52 1.51 2.60 2.60 3.89 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.4 A++

26 26 26 26 2.65 2.65 2.65 2.65 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++

26 26 26 35 2.45 2.45 2.45 3.26 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++

26 26 26 52 2.12 2.12 2.12 4.24 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++

26 26 35 35 2.27 2.27 3.03 3.03 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++

26 26 35 52 1.99 1.99 2.65 3.98 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++

26 35 35 35 2.12 2.83 2.83 2.83 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++

26 35 35 52 1.87 2.49 2.49 3.74 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.4 A++

35 35 35 35 2.65 2.65 2.65 2.65 3.71 10.60 13.78 0.89 3.30 4.29 3.21 7.6 A++

COMBINATIONS RATED CAPACITY (KW) HEATING CAPACITY (KW) POWER INPUT (KW)COP

(W/W)SCOP

ENERGY CLASS

COP -7

1x4

UNIT A

UNIT B

UNIT C

UNIT D

UNIT A

UNIT B

UNIT C

UNIT D

MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY

20 20 20 20 2.50 2.50 2.50 2.50 3.89 10.00 11.10 0.83 2.59 3.06 3.86 3.8 A 3.20

20 20 20 26 2.36 2.36 2.36 3.03 3.89 10.10 11.66 0.83 2.69 3.21 3.75 3.8 A 3.11

20 20 20 35 2.31 2.31 2.31 3.96 3.89 10.90 12.21 0.83 2.95 3.36 3.70 3.8 A 3.07

20 20 20 52 1.99 1.99 1.99 5.12 3.89 11.10 13.32 0.83 3.04 3.98 3.65 3.8 A 3.02

20 20 20 71 1.73 1.73 1.73 5.92 3.89 11.10 13.32 0.83 3.04 3.98 3.65 3.8 A 3.02

20 20 26 26 2.38 2.38 3.07 3.07 3.89 10.90 12.21 0.83 2.95 3.36 3.70 3.8 A 3.07

20 20 26 35 2.22 2.22 2.85 3.81 3.89 11.10 12.77 0.83 3.00 3.67 3.70 3.8 A 3.07

20 20 26 52 1.90 1.90 2.44 4.87 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01

20 20 26 71 1.65 1.65 2.13 5.67 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01

20 20 35 35 2.04 2.04 3.51 3.51 3.89 11.10 13.32 0.83 3.04 3.98 3.65 3.8 A 3.02

20 20 35 52 1.77 1.77 3.03 4.54 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01

20 20 52 52 1.55 1.55 4.00 4.00 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01

20 26 26 26 2.29 2.94 2.94 2.94 3.89 11.10 12.77 0.83 3.00 3.52 3.70 3.8 A 3.07

20 26 26 35 2.10 2.70 2.70 3.60 3.89 11.10 13.32 0.83 3.05 3.98 3.64 3.8 A 3.02

20 26 26 52 1.81 2.32 2.32 4.65 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01

20 26 26 71 1.59 2.04 2.04 5.44 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01

20 26 35 35 1.94 2.50 3.33 3.33 3.89 11.10 13.32 0.83 3.05 3.98 3.64 3.8 A 3.02

20 26 35 52 1.69 2.17 2.90 4.34 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01

20 26 52 52 1.49 1.92 3.84 3.84 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01

20 35 35 35 1.81 3.10 3.10 3.10 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01

20 35 35 52 1.59 2.72 2.72 4.08 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01

26 26 26 26 2.78 2.78 2.78 2.78 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01

26 26 26 35 2.56 2.56 2.56 3.42 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01

26 26 26 52 2.22 2.22 2.22 4.44 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01

26 26 35 35 2.38 2.38 3.17 3.17 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01

26 26 35 52 2.08 2.08 2.78 4.16 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01

26 35 35 35 2.22 2.96 2.96 2.96 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01

26 35 35 52 1.96 2.61 2.61 3.92 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01

35 35 35 35 2.78 2.78 2.78 2.78 3.89 11.10 13.32 0.83 3.06 3.98 3.63 3.8 A 3.01

BUSINESS GROUP

66

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

COMBINED SYSTEMSKAM5-120 DN7

20 20+20 20+20+20 20+20+20+20 20+20+20+20+20

26 20+26 20+20+26 20+20+20+26 20+20+20+20+26

35 20+35 20+20+35 20+20+20+35 20+20+20+20+35

52 20+52 20+20+52 20+20+20+52 20+20+20+20+52

71 20+71 20+20+71 20+20+20+71 20+20+20+20+71

26+26 20+26+26 20+20+26+26 20+20+20+26+26

26+35 20+26+35 20+20+26+35 20+20+20+26+35

26+52 20+26+52 20+20+26+52 20+20+20+26+52

26+71 20+26+71 20+20+26+71 20+20+20+26+71

35+35 20+35+35 20+20+35+35 20+20+20+35+35

35+52 20+35+52 20+20+35+52 20+20+20+35+52

35+71 20+35+71 20+20+35+71 20+20+20+35+71

52+52 20+52+52 20+20+52+52 20+20+20+52+52

52+71 26+26+26 20+20+52+71 20+20+26+26+26

71+71 26+26+35 20+26+26+26 20+20+26+26+35

26+26+52 20+26+26+35 20+20+26+26+52

26+26+71 20+26+26+52 20+20+26+26+71

26+35+35 20+26+26+71 20+20+26+35+35

26+35+52 20+26+35+35 20+20+26+35+52

26+35+71 20+26+35+52 20+20+26+52+52

26+52+52 20+26+35+71 20+20+35+35+35

35+35+35 20+26+52+52 20+20+35+35+52

35+35+52 20+26+52+71 20+26+26+26+26

35+35+71 20+35+35+35 20+26+26+26+35

35+52+52 20+35+35+52 20+26+26+26+52

35+52+71 20+35+52+52 20+26+26+26+71

52+52+52 20+35+52+71 20+26+26+35+35

26+26+26+26 20+26+26+35+52

26+26+26+35 20+26+35+35+35

26+26+26+52 20+26+35+35+52

26+26+26+71 20+35+35+35+35

26+26+35+35 26+26+26+26+26

26+26+35+52 26+26+26+26+35

26+26+35+71 26+26+26+26+52

26+26+52+52 26+26+26+35+35

26+35+35+35 26+26+26+35+52

26+35+35+52 26+26+35+35+35

26+35+35+71 26+35+35+35+35

26+35+52+52

35+35+35+35

35+35+35+52

x1 x2 x3 x4 x5

R-410A MULTISYSTEM

RESIDENTIAL RANGE COMBINED SYSTEMS

67

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

COMBINATIONS RATED CAPACITY (kW)COOLING CAPACITY

(kW)INPUT

POWER (kW)EER

(W/W)SEER

(W/W)ENERGY CLASS

5x

UNIT A UNIT B UNIT C UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E MIN. RAT. MAX. MIN. RAT. MAX.RATED

CAPACITY

20 20 20 20 20 2.10 2.10 2.10 2.10 2.10 4.18 10.50 14.00 1.01 3.09 4.55 3.40 7.7 A++20 20 20 20 26 2.08 2.08 2.08 2.08 2.68 4.18 11.00 14.00 1.01 3.24 4.55 3.40 7.7 A++20 20 20 20 35 2.01 2.01 2.01 2.01 3.45 4.18 11.50 14.00 1.01 3.42 4.55 3.37 7.7 A++20 20 20 20 52 1.87 1.87 1.87 1.87 4.81 4.18 12.30 14.00 1.01 3.73 4.55 3.30 7.7 A++20 20 20 20 71 1.66 1.66 1.66 1.66 5.68 4.18 12.30 14.00 1.01 3.76 4.55 3.27 7.7 A++20 20 20 26 26 2.06 2.06 2.06 2.65 2.65 4.18 11.50 14.00 1.01 3.42 4.55 3.37 7.7 A++20 20 20 26 35 2.00 2.00 2.00 2.57 3.43 4.18 12.00 14.00 1.01 3.57 4.55 3.37 7.7 A++20 20 20 26 52 1.79 1.79 1.79 2.31 4.61 4.18 12.30 14.00 1.01 3.73 4.55 3.30 7.7 A++20 20 20 26 71 1.59 1.59 1.59 2.05 5.47 4.18 12.30 14.00 1.01 3.76 4.55 3.27 7.7 A++20 20 20 35 35 1.91 1.91 1.91 3.28 3.28 4.18 12.30 14.00 1.01 3.69 4.55 3.33 7.7 A++20 20 20 35 52 1.69 1.69 1.69 2.89 4.34 4.18 12.30 14.00 1.01 3.75 4.55 3.28 7.7 A++20 20 20 35 71 1.51 1.51 1.51 2.59 5.18 4.18 12.30 14.00 1.01 3.80 4.55 3.23 7.7 A++20 20 20 52 52 1.51 1.51 1.51 3.88 3.88 4.18 12.30 14.00 1.01 3.80 4.55 3.23 7.7 A++20 20 26 26 26 2.05 2.05 2.63 2.63 2.63 4.18 12.00 14.00 1.01 3.57 4.55 3.37 7.7 A++20 20 26 26 35 1.96 1.96 2.52 2.52 3.35 4.18 12.30 14.00 1.01 3.69 4.55 3.33 7.7 A++20 20 26 26 52 1.72 1.72 2.21 2.21 4.43 4.18 12.30 14.00 1.01 3.75 4.55 3.28 7.7 A++20 20 26 26 71 1.54 1.54 1.98 1.98 5.27 4.18 12.30 14.00 1.01 3.80 4.55 3.23 7.7 A++20 20 26 35 35 1.83 1.83 2.36 3.14 3.14 4.18 12.30 14.00 1.01 3.73 4.55 3.30 7.7 A++20 20 26 35 52 1.62 1.62 2.09 2.78 4.18 4.18 12.30 14.00 1.01 3.76 4.55 3.27 7.7 A++20 20 26 52 52 1.46 1.46 1.88 3.75 3.75 4.18 12.30 14.00 1.01 3.84 4.55 3.20 7.7 A++20 20 35 35 35 1.72 1.72 2.95 2.95 2.95 4.18 12.30 14.00 1.01 3.73 4.55 3.30 7.7 A++20 20 35 35 52 1.54 1.54 2.64 2.64 3.95 4.18 12.30 14.00 1.01 3.76 4.55 3.27 7.7 A++20 26 26 26 26 2.00 2.57 2.57 2.57 2.57 4.18 12.30 14.00 1.01 3.69 4.55 3.33 7.7 A++20 26 26 26 35 1.87 2.41 2.41 2.41 3.21 4.18 12.30 14.00 1.01 3.73 4.55 3.30 7.7 A++20 26 26 26 52 1.66 2.13 2.13 2.13 4.26 4.18 12.30 14.00 1.01 3.76 4.55 3.27 7.7 A++20 26 26 26 71 1.48 1.91 1.91 1.91 5.09 4.18 12.30 14.00 1.01 3.80 4.55 3.23 7.7 A++20 26 26 35 35 1.76 2.26 2.26 3.01 3.01 4.18 12.30 14.00 1.01 3.73 4.55 3.30 7.7 A++20 26 26 35 52 1.57 2.01 2.01 2.68 4.03 4.18 12.30 14.00 1.01 3.76 4.55 3.27 7.7 A++20 26 35 35 35 1.66 2.13 2.84 2.84 2.84 4.18 12.30 14.00 1.01 3.75 4.55 3.28 7.7 A++20 26 35 35 52 1.48 1.91 2.54 2.54 3.82 4.18 12.30 14.00 1.01 3.80 4.55 3.23 7.7 A++20 35 35 35 35 1.57 2.68 2.68 2.68 2.68 4.18 12.30 14.00 1.01 3.75 4.55 3.28 7.7 A++26 26 26 26 26 2.46 2.46 2.46 2.46 2.46 4.18 12.30 14.00 1.01 3.73 4.55 3.30 7.7 A++26 26 26 26 35 2.31 2.31 2.31 2.31 3.08 4.18 12.30 14.00 1.01 3.73 4.55 3.30 7.7 A++26 26 26 26 52 2.05 2.05 2.05 2.05 4.10 4.18 12.30 14.00 1.01 3.76 4.55 3.27 7.7 A++26 26 26 35 35 2.17 2.17 2.17 2.89 2.89 4.18 12.30 14.00 1.01 3.75 4.55 3.28 7.7 A++26 26 26 35 52 1.94 1.94 1.94 2.59 3.88 4.18 12.30 14.00 1.01 3.80 4.55 3.23 7.7 A++26 26 35 35 35 2.05 2.05 2.73 2.73 2.73 4.18 12.30 14.00 1.01 3.75 4.55 3.28 7.7 A++26 35 35 35 35 1.94 2.59 2.59 2.59 2.59 4.18 12.30 14.00 1.01 3.76 4.55 3.27 7.7 A++

COMBINATIONS RATED CAPACITY (kW)HEATING

CAPACITY (kW)INPUT

POWER (kW)COP

(W/W)SCOP

ENERGY CLASS

COP -7

5X1

UNIT A UNIT B UNIT C UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E MIN. RAT. MAX. MIN. RAT. MAX.RATED

CAPACITY

20 20 20 20 20 2.46 2.46 2.46 2.46 2.46 4.18 12.30 14.94 0.91 3.40 4.21 3.62 3.7 A 2.9420 20 20 20 26 2.33 2.33 2.33 2.33 2.99 4.18 12.30 14.94 0.91 3.40 4.21 3.62 3.8 A 2.9420 20 20 20 35 2.15 2.15 2.15 2.15 3.69 4.18 12.30 14.94 0.91 3.40 4.21 3.62 3.8 A 2.9420 20 20 20 52 1.87 1.87 1.87 1.87 4.81 4.18 12.30 14.94 0.91 3.37 4.21 3.65 3.8 A 2.9420 20 20 20 71 1.66 1.66 1.66 1.66 5.68 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.6 A 2.9420 20 20 26 26 2.21 2.21 2.21 2.84 2.84 4.18 12.30 14.94 0.91 3.40 4.21 3.62 3.8 A 2.9420 20 20 26 35 2.05 2.05 2.05 2.64 3.51 4.18 12.30 14.94 0.91 3.40 4.21 3.62 3.8 A 2.9420 20 20 26 52 1.79 1.79 1.79 2.31 4.61 4.18 12.30 14.94 0.91 3.32 4.21 3.71 3.8 A 2.9420 20 20 26 71 1.59 1.59 1.59 2.05 5.47 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.8 A 2.9420 20 20 35 35 1.91 1.91 1.91 3.28 3.28 4.18 12.30 14.94 0.91 3.40 4.21 3.62 3.8 A 2.9420 20 20 35 52 1.69 1.69 1.69 2.89 4.34 4.18 12.30 14.94 0.91 3.32 4.21 3.71 3.6 A 2.9420 20 20 35 71 1.51 1.51 1.51 2.59 5.18 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.5 A 2.9420 20 20 52 52 1.51 1.51 1.51 3.88 3.88 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.5 A 2.9420 20 26 26 26 2.10 2.10 2.70 2.70 2.70 4.18 12.30 14.94 0.91 3.40 4.21 3.62 3.8 A 2.9420 20 26 26 35 1.96 1.96 2.52 2.52 3.35 4.18 12.30 14.94 0.91 3.40 4.21 3.62 3.8 A 2.9420 20 26 26 52 1.72 1.72 2.21 2.21 4.43 4.18 12.30 14.94 0.91 3.32 4.21 3.71 3.8 A 2.9420 20 26 26 71 1.54 1.54 1.98 1.98 5.27 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.5 A 2.9420 20 26 35 35 1.83 1.83 2.36 3.14 3.14 4.18 12.30 14.94 0.91 3.37 4.21 3.65 3.6 A 2.9420 20 26 35 52 1.62 1.62 2.09 2.78 4.18 4.18 12.30 14.94 0.91 3.37 4.21 3.65 3.6 A 2.9420 20 26 52 52 1.46 1.46 1.88 3.75 3.75 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.4 A 2.9420 20 35 35 35 1.72 1.72 2.95 2.95 2.95 4.18 12.30 14.94 0.91 3.37 4.21 3.65 3.6 A 2.9420 20 35 35 52 1.54 1.54 2.64 2.64 3.95 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.6 A 2.9420 26 26 26 26 2.00 2.57 2.57 2.57 2.57 4.18 12.30 14.94 0.91 3.40 4.21 3.62 3.8 A 2.9420 26 26 26 35 1.87 2.41 2.41 2.41 3.21 4.18 12.30 14.94 0.91 3.37 4.21 3.65 3.8 A 2.9420 26 26 26 52 1.66 2.13 2.13 2.13 4.26 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.8 A 2.9420 26 26 26 71 1.48 1.91 1.91 1.91 5.09 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.5 A 2.9420 26 26 35 35 1.76 2.26 2.26 3.01 3.01 4.18 12.30 14.94 0.91 3.37 4.21 3.65 3.8 A 2.9420 26 26 35 52 1.57 2.01 2.01 2.68 4.03 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.6 A 2.9420 26 35 35 35 1.66 2.13 2.84 2.84 2.84 4.18 12.30 14.94 0.91 3.32 4.21 3.71 3.6 A 2.9420 26 35 35 52 1.48 1.91 2.54 2.54 3.82 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.4 A 2.9420 35 35 35 35 1.57 2.68 2.68 2.68 2.68 4.18 12.30 14.94 0.91 3.32 4.21 3.71 3.6 A 2.9426 26 26 26 26 2.46 2.46 2.46 2.46 2.46 4.18 12.30 14.94 0.91 3.37 4.21 3.65 3.8 A 2.9426 26 26 26 35 2.31 2.31 2.31 2.31 3.08 4.18 12.30 14.94 0.91 3.37 4.21 3.65 3.8 A 2.9426 26 26 26 52 2.05 2.05 2.05 2.05 4.10 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.5 A 2.9426 26 26 35 35 2.17 2.17 2.17 2.89 2.89 4.18 12.30 14.94 0.91 3.32 4.21 3.71 3.6 A 2.9426 26 26 35 52 1.94 1.94 1.94 2.59 3.88 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.5 A 2.9426 26 35 35 35 2.05 2.05 2.73 2.73 2.73 4.18 12.30 14.94 0.91 3.32 4.21 3.71 3.6 A 2.9426 35 35 35 35 1.94 2.59 2.59 2.59 2.59 4.18 12.30 14.94 0.91 3.28 4.21 3.75 3.5 A 2.94

BUSINESS GROUP

68

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

*Sound pressure in “Silence” mode.

AUREA II R-32 MULTISYSTEM

TECHNICAL SPECIFICATIONS

MODEL KAY-S 26 DR7 KAY-S 35 DR7 KAY-S 52 DR7 KAY-S 71 DR7

Cooling capacity kW 2.78 3.66 5.28 7.33

Cooling capacity Kcal/h 2268 3024 4536 6300

Heating capacity kW 2.93 3.81 5.57 7.62

Heating capacity Kcal/h 2520 3276 4788 6552

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

Airflow m3/h 515/459/337 515/459/337 750/505/420 1050/750/560

Sound pressure* dB (A) 21 23 21 26

Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8")

Gas pipe diameter mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") ø15.9(5/8")

Width/Height/Depth mm 802/297/189 802/297/189 965/319/215 1080/335/226

Net weight Kg 8 8 9 12

Power wiring mm2 From outdoor From outdoor From outdoor From outdoor

Communication wiring mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5

NEW

INDOOR UNITSRESIDENTIAL RANGE

69

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

ERP

BMS AND SOFTWARE

CONTROLS

K01-WIFI

GENERAL CHARACTERISTICS

AUREA II, the medium category range of KAYSUN UK, is characterised by its versatile nature: it can run on R-410A or R-32 refrigerant. In addition to a simple and elegant design, it incorporates all of KAYSUN’s most advanced characteristics and technologies.

• Optional WIFI control adding K03 WIFI USB.

• Mono-Multi compatible.

• White translucent smart DISPLAY with information on the equipment and alarm systems status.

• The display and buzzer have a switch-off option which can be activated if they annoy the user.

• KID-02 S controller included to control unit's work parameters and change its configuration.

• Louvres position memory.

• Drainage pipe connection from left or right option.

WIFI CONTROL (OPTIONAL)+

21 dB SOUND PRESSURE+

COMPATIBLE WITH

MULTISYSTEM OUTDOOR UNITS

see pag. 72

K03 WIFI USB ACCESSORY

OPTIONAL WIFI

KID-02 SSTANDARD

PRICE LIST

MODEL STANDARD CONTROLLER PRICE SET £

KAY-S 26 DR7 KID-02 S £131

KAY-S 35 DR7 KID-02 S £139

KAY-S 52 DR7 KID-02 S £239

KAY-S 71 DR7 KID-02 S £277

ACCESSORIES

MODEL PRICE

K03 WIFI USB ACCESSORY £36

BUSINESS GROUP

70

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

MODEL KAM2-52 DR7 KAM3-78 DR7 KAM4-105 DR7 KAM5-120 DR7

Cooling capacity kW 5.28 7.91 10.55 12.31

Cooling capacity Kcal/h 4536 6804 9072 10584

Cooling input kW 1750 2470 3517 3800

Heating capacity kW 5.57 8.21 11140 12.60

Heating capacity Kcal/h 4788 7056 9576 10836

Heating input kW 1450 2350 2880 3300

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

Compressor type Rotary Rotary Rotary Rotary

Outdoor airflow m3/h 2200 2700 4000 3850

Sound pressure dB (A) 56 59 63 62

Refrigerant R-32 R-32 R-32 R-32

Additional refrigerant charge* gr 1300 1570 2100 2400

Pre-charge metres* m 15 22.5 30 37.5

Liquid pipe diameter mm (Inch) ø6.35 (1/4") x 2 ø6.35 (1/4") x 3 ø6.35 (1/4") x 4 ø6.35 (1/4") x 5

Gas pipe diameter mm (Inch) ø9.52 (3/8") x 2 ø9.52 (3/8") x 3 ø9.52 (3/8") x 3 + ø12.7 (1/2") x 1

ø9.52 (3/8") x 3 + ø12.7 (1/2") x 2

Max. piping length m 40 60 80 80

Piping max. length (1 indoor unit) m 25 30 35 35

Height difference between indoor and outdoor units

m 15 15 15 15

Height difference between indoor units m 10 10 10 10

Width/Height/Depth mm 800/554/333 845/702/363 946/810/410 946/810/410

Net weight Kg 36.0 53.0 68.8 73.3

Maximum number of indoor units 2 3 4 5

Power wiring mm2 (2+T)x2.5 (2+T)x4 (2+T)x6 (2+T)x6

Communication wiring mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5

OUTDOOR UNITS

TECHNICAL SPECIFICATIONS

R-32 MULTISYSTEM NEW

RESIDENTIAL RANGE OUTDOOR UNITS

71

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

ERP

KAYSUN UK MULTISYSTEM outdoor units, with their strong structure, provide greater output with less noise pollution.

QUIET+

STRONG +

PRICE LIST

MODEL PRICE

KAM2-52 DR7 £837

KAM3-78 DR7 £1,191

KAM4-105 DR7 £1,621

KAM5-120 DR7 £1,940

BUSINESS GROUP

72

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

KAM2-52 DR7

26 26+26

35 26+35

52 26+52

35+35

x1 x2

COMBINED SYSTEMS

KAM3-78 DR7

26 26+26 26+26+26

35 26+35 26+26+35

52 26+52 26+26+52

35+35 26+35+35

35+52 26+35+52

52+52 35+35+35

x1 x2 x3

R-32 MULTISYSTEM

RESIDENTIAL RANGE COMBINED SYSTEMS

73

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

COMBINATIONSRATED

CAPACITY (kW)COOLING

CAPACITY (kW)INPUT

POWER (kW)EER

(W/W)SEER ENERGY CLASS

1x2

UNIT A

UNIT B

UNIT A

UNIT B

MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY

26 26 2.64 2.64 2.11 5.28 6.44 0.54 1.63 2.04 3.23 6.6 A++

26 35 2.27 3.03 2.11 5.3 6.44 0.54 1.64 2.04 3.23 6.6 A++

26 52 1.8 3.6 2.11 5.4 6.49 0.54 1.65 2.04 3.27 6.6 A++

35 35 2.65 2.65 2.11 5.3 6.44 0.54 1.64 2.04 3.23 6.6 A++

COMBINATIONSRATED

CAPACITY (kW)HEATING

POWER (kW)INPUT

POWER (kW)COP

(W/W)SCOP

ENERGY CLASS

COP -7

1x2

UNIT A

UNIT B

UNIT A

UNIT B

MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUMRATED

CAPACITY

26 26 2.79 2.79 2.23 5.57 6.8 0.47 1.39 1.88 4.0 4.0 A+ 3.2

26 35 2.4 3.2 2.23 5.6 6.8 0.47 1.4 1.88 4.0 4.0 A+ 3.2

26 52 1.93 3.87 2.23 5.8 6.85 0.47 1.46 1.88 3.97 4.0 A+ 3.17

35 35 2.8 2.8 2.23 5.6 6.8 0.47 1.4 1.88 4.0 4.0 A+ 3.2

COMBINATIONSRATED

CAPACITY (kW)COOLING

CAPACITY (kW)INPUT

POWER (kW)EER

(W/W)SEER

ENERGY CLASS

1x3

UNIT A UNIT B UNIT C UNIT A UNIT B UNIT C MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY

26 26 26 2.63 2.63 2.63 2.77 7.9 8.69 0.74 2.39 2.9 3.3 6.7 A++

26 26 35 2.37 2.37 3.16 2.77 7.9 8.69 0.74 2.39 2.9 3.31 6.7 A++

26 26 52 1.98 1.98 3.95 2.77 7.9 8.69 0.74 2.39 2.9 3.31 6.7 A++

26 35 35 2.15 2.87 2.87 2.77 7.9 8.69 0.74 2.38 2.9 3.32 6.7 A++

26 35 52 1.82 2.43 3.65 2.77 7.9 8.69 0.74 2.38 2.9 3.32 6.7 A++

35 35 35 2.63 2.63 2.63 2.77 7.9 8.69 0.74 2.38 2.9 3.32 6.7 A++

COMBINATIONSRATED

CAPACITY (kW)HEATING

POWER (kW)INPUT

POWER (kW)COP

(W/W)SCOP

ENERGY CLASS

COP -7

1x3

UNIT A UNIT B UNIT C UNIT A UNIT B UNIT C MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY

26 26 26 2.73 2.73 2.73 2.87 8.2 9.02 0.68 2.20 2.62 3.73 4.0 A+ 3.13

26 26 35 2.49 2.49 3.32 2.87 8.3 9.02 0.68 2.22 2.62 3.74 4.0 A+ 3.14

26 26 52 2.08 2.08 4.15 2.87 8.3 9.02 0.68 2.22 2.62 3.74 4.0 A+ 3.14

26 35 35 2.26 3.02 3.02 2.87 8.3 9.02 0.68 2.21 2.62 3.76 4.0 A+ 3.16

26 35 52 1.92 2.56 3.83 2.87 8.3 9.02 0.68 2.22 2.62 3.74 4.0 A+ 3.14

35 35 35 2.77 2.77 2.77 2.87 8.3 9.02 0.68 2.21 2.62 3.76 4.0 A+ 3.16

BUSINESS GROUP

74

POWER RANGE

Go back to General Contents Go back to SUITE Index(Index)

COMBINED SYSTEMS

KAM4-105 DR7

26 26+26 26+26+26 26+26+26+26

35 26+35 26+26+35 26+26+26+35

52 26+52 26+26+52 26+26+26+52

70 26+70 26+26+70 26+26+35+35

35+35 26+35+35 26+26+35+52

35+52 26+35+52 26+35+35+35

35+70 26+35+70 26+35+35+52

52+52 26+52+52 35+35+35+35

35+35+35 35+35+35+52

35+35+52

35+35+70

35+52+52

KAM5-120 DR7

26 26+26 26+26+26 26+26+26+26 26+26+26+26+26

35 26+35 26+26+35 26+26+26+35 26+26+26+26+35

52 26+52 26+26+52 26+26+26+52 26+26+26+26+52

71 26+71 26+26+71 26+26+26+71 26+26+26+35+35

35+35 26+35+35 26+26+35+35 26+26+26+35+52

35+52 26+35+52 26+26+35+52 26+26+35+35+35

35+71 26+35+71 26+26+35+71 26+35+35+35+35

52+52 26+52+52 26+35+35+35 26+35+35+35+52

35+35+35 26+35+35+52 35+35+35+35+35

35+35+52 35+35+35+35

35+35+71 35+35+35+52

35+52+52

x1

x1

x2

x2

x3 x4

x4 x5x3

R-32 MULTISYSTEM

RESIDENTIAL RANGE COMBINED SYSTEMS

75

Design and Install for you

SU

ITE

R

ES

IDE

NTI

AL

Go back to General Contents Go back to SUITE Index(Index)

1x4

UNIT A UNIT B UNIT C UNIT UNIT A UNIT B UNIT C UNIT D MIN. RATED MAX. MIN. RATED MAX. RATED CAPACITY

26 26 26 26 2.63 2.63 2.63 2.63 3.68 10.5 13.65 0.95 3.5 4.27 3.0 6.5 A++

26 26 26 35 2.42 2.42 2.42 3.23 3.68 10.5 13.65 0.95 3.5 4.27 3.0 6.5 A++

26 26 26 52 2.1 2.1 2.1 4.2 3.68 10.5 13.65 0.95 3.5 4.27 3.0 6.5 A++

26 26 35 35 2.25 2.25 3 3 3.68 10.5 13.65 0.95 3.5 4.27 3.0 6.5 A++

26 26 35 52 1.97 1.97 2.63 3.94 3.68 10.5 13.65 0.95 3.5 4.27 3.0 6.5 A++

26 35 35 35 2.1 2.8 2.8 2.8 3.68 10.5 13.65 0.95 3.5 4.27 3.0 6.5 A++

26 35 35 52 1.85 2.47 2.47 3.71 3.68 10.5 13.65 0.95 3.5 4.27 3.0 6.5 A++

35 35 35 35 2.63 2.63 2.63 2.63 3.68 10.5 13.65 0.95 3.5 4.27 3.0 6.5 A++

35 35 35 52 2.33 2.33 2.33 3.5 3.68 10.5 13.65 0.95 3.5 4.27 3.0 6.5 A++

1x4

UNIT AUNIT

BUNIT

CUNIT

UNIT A

UNIT B

UNIT C

UNIT D

MIN. RATED MAX. MIN. RATED MAX. RATED CAPACITY

26 26 26 26 2.78 2.78 2.78 2.78 3.89 11.1 13.32 0.79 2.91 3.79 3.81 4.0 A 3.11

26 26 26 35 2.56 2.56 2.56 3.42 3.89 11.1 13.32 0.79 2.91 3.79 3.81 4.0 A 3.11

26 26 26 52 2.22 2.22 2.22 4.44 3.89 11.1 13.32 0.79 2.91 3.79 3.81 4.0 A 3.11

26 26 35 35 2.38 2.38 3.17 3.17 3.89 11.1 13.32 0.79 2.91 3.79 3.81 4.0 A 3.11

26 26 35 52 2.08 2.08 2.78 4.16 3.89 11.1 13.32 0.79 2.91 3.79 3.81 4.0 A 3.11

26 35 35 35 2.22 2.96 2.96 2.96 3.89 11.1 13.32 0.79 2.91 3.79 3.81 4.0 A 3.11

26 35 35 52 1.96 2.61 2.61 3.92 3.89 11.1 13.32 0.79 2.91 3.79 3.81 4.0 A 3.11

35 35 35 35 2.78 2.78 2.78 2.78 3.89 11.1 13.32 0.79 2.91 3.79 3.81 4.0 A 3.11

35 35 35 52 2.47 2.47 2.47 3.70 3.89 11.1 13.32 0.79 2.91 3.79 3.81 4.0 A 3.11

RATED CAPACITY (KW)

RATED CAPACITY (KW)

COOLING CAPACITY (KW)

HEATING CAPACITY (KW)

EERW/W

COPW/W

SEER

SCOP COP -7

ENERGY CLASS

ENERGY CLASS

INPUT POWER (kW)

INPUT POWER (kW)

COMBINATIONS

COMBINATIONS

COMBINATIONS RATED CAPACITY (kW)COOLING

CAPACITY (kW)INPUT

POWER (kW)EER

(W/W)SEER

(W/W)ENERGY CLASS

1x5

UNIT A UNIT B UNIT C UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E MIN. RAT. MAX. MIN. RAT. MAX.RATED

CAPACITY

26 26 26 26 26 2.46 2.46 2.46 2.46 2.46 4.18 12.3 14 1.11 4.1 4.55 3.0 6.8 A++

26 26 26 26 35 2.31 2.31 2.31 2.31 3.08 4.18 12.3 14 1.11 4.1 4.55 3.0 6.8 A++

26 26 26 26 52 2.05 2.05 2.05 2.05 4.1 4.18 12.3 14 1.11 4.09 4.55 3.01 6.8 A++

26 26 26 35 35 2.17 2.17 2.17 2.89 2.89 4.18 12.3 14 1.11 4.07 4.55 3.02 6.8 A++

26 26 26 35 52 1.94 1.94 1.94 2.59 3.88 4.18 12.3 14 1.11 4.09 4.55 3.01 6.8 A++

26 26 35 35 35 2.05 2.05 2.73 2.73 2.73 4.18 12.3 14 1.11 4.07 4.55 3.02 6.8 A++

26 35 35 35 35 1.94 2.59 2.59 2.59 2.59 4.18 12.3 14 1.11 4.09 4.55 3.01 6.8 A++

26 35 35 35 52 1.76 2.34 2.34 2.34 3.51 4.182 12.3 14 1.11 4.09 4.55 3.00 6.8 A++

35 35 35 35 35 2.46 2.46 2.46 2.46 2.46 4.182 12.3 14 1.11 4.09 4.55 3.00 6.8 A++

COMBINATIONS RATED CAPACITY (kW)HEATING

CAPACITY (kW)INPUT

POWER (kW)COP

(W/W)SCOP

ENERGY CLASS

COP -7

1x5

UNIT A UNIT B UNIT C UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E MIN. RAT. MAX. MIN. RAT. MAX.RATED

CAPACITY

26 26 26 26 26 2.46 2.46 2.46 2.46 2.46 4.18 12.3 14.94 0.9 3.32 4.14 3.71 4.0 A 3.01

26 26 26 26 35 2.31 2.31 2.31 2.31 3.08 4.18 12.3 14.94 0.9 3.32 4.14 3.71 4.0 A 3.01

26 26 26 26 52 2.05 2.05 2.05 2.05 4.1 4.18 12.3 14.94 0.9 3.23 4.14 3.81 3.5 A 3.11

26 26 26 35 35 2.17 2.17 2.17 2.89 2.89 4.18 12.3 14.94 0.9 3.26 4.14 3.77 3.8 A 3.07

26 26 26 35 52 1.94 1.94 1.94 2.59 3.88 4.18 12.3 14.94 0.9 3.23 4.14 3.81 3.5 A 3.11

26 26 35 35 35 2.05 2.05 2.73 2.73 2.73 4.18 12.3 14.94 0.9 3.3 4.14 3.77 3.8 A 3.07

26 35 35 35 35 1.94 2.59 2.59 2.59 2.59 4.18 12.3 14.94 0.9 3.2 4.14 3.81 3.5 A 3.11

26 35 35 35 52 1.84 1.84 2.46 2.46 3.69 4.182 12.3 14.94 0.9 3.2 4.14 3.81 3.8 A 3.11

35 35 35 35 35 2.46 2.46 2.46 2.46 2.46 4.182 12.3 14.94 0.9 3.2 4.14 3.81 3.5 A 3.11

ZEN AXIAL COMMERCIAL RANGE

77

Design and Install for you

INTRODUCTION TO THE PRODUCT RANGE ..............................................78

SETS ........................................................................................................... ..80

CASSETTE (600X600) ....................................................................... ..82

SUPERSLIM CASSETTE ..................................................................... ..84

CEILING/FLOOR ................................................................................. ..88

DUCTS ....................................................................................................92

STATIC PRESSURE GRAPHS ....................................................... ..96

TWINS ........................................................................................................100

CASSETTE (600X600) .........................................................................101

SUPERSLIM CASSETTE .......................................................................101

DUCTS .................................................................................................. 102

CEILING/FLOOR ................................................................................ ..103

ZENAXIAL COMMERCIAL RANGE

78

COMMERCIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

AXIAL COMMERCIAL RANGE

ZEN

OUTDOOR UNITS

We wish to highlight the axial outdoor units of KAYSUN’s Zen range. This is a machine designed to make maintenance tasks easier and to protect its main components, thereby extending the shelf life of the product.

We present the KAYSUN UK commercial range with axial outdoor ventilators. The main characteristics of this range we wish to highlight are its advanced technology, its efficiency, its versatility and its performance.

Combinations made with axial outdoor units are fitted with Inverter technology, maximising energy efficiency and seasonal performance indicators with a SCOP 4.0. The outdoor units of this type have an aesthetic with a robust design and good sound performance.

As part of the ZEN range with axial ventilator condensers, we have a wide variety of indoor units: Compact cassette

(600x600), SuperSlim cassette (840x840), ducts and Floor/Ceiling units. Some of these units can be installed in a TWINS configuration (one outdoor unit with two indoor units working together).

It could be said that the controls of this range are at the expected height. The KID-02 S, a wireless smart control that can inspect the operation of units and change configuration parameters. In terms of controls we have the KC-03 SPS, which can control up to 16 indoor units. Furthermore, it should be pointed out that this year some models in this range will have optional Wi-Fi control.

SMART CONTROLLERS

KAYSUN’s ZEN range has a range of controls at altitude. The cable and wireless controls have the most technologically-advanced functions and utilities, but with a modern and avant-garde aesthetic.

INSTALLATION PARAMETRES MODIFICATION+INSPECTION OF OPERATING PARAMETERS+FOLLOW ME+

WEEKLY TIMER+

FOLLOW ME+

UP TO 16 INDOOR UNITS+

STRONGER AND COMPACT+PERFORMANCE+ENERGY SAVING

SOUND LEVEL

+

KC-03 SPS KID-02 S

“HIGH-PERFORMANCE COMMERCIAL EQUIPMENT”

Go back to General Contents Go back to ZENaxial Index(Index)

79

Design and Install for you

ZE

N

AX

IAL

COM

ME

RCI

ALDUCT UNIT

With regard to the semi-industrial indoor units of the ZEN RANGE, we would like to highlight the Duct unit. We believe that this is one of the most comprehensive units in the market due to the great amount of options and functions included, such as:

• Removable filter (it can be extracted without touching the unit).

• Frame for the air inlet.• Frame for the air outlet.• Double possibility of air inlet (rear outlet or lower outlet).• Condensation pump.• Pre-installation for fresh air inlet.

• Electric box removable up to 1 metre apart from the unit's body.

• Voltage-free Alarm and ON/OFF dry contacts.• Switch to adapt the unit to the duct and to adjust the flow

required by the installation.• Up to 100 Pa available depending on the model.

TWO COMMUNICATION WIRESThe ZEN range units* only require two shielded wires without polarity for the communication between units. This characteristic makes the communication wiring works cheaper and easier.

WIFI ADAPTORIn 2017, KAYSUN UK will unveil its new optional adaptor for units in the ZEN range. These accessories connect the unit to our WIFI network and control it through an App installed on our smartphone. The application also includes a weekly timer

built into the App to ease and improve the control function of our air-conditioning system.

*Except for 3.5 kW units and high capacity Duct units.

S1

S1

S2

S2

NEW

Go back to General Contents Go back to ZENaxial Index(Index)

80

COMMERCIAL RANGE SETS - AXIAL

SETSAXIAL

81

Design and Install for you

ZE

N

AX

IAL

COM

ME

RCI

AL

3.5 5.2 7.1 9.0 10.5 12.5 14.0 16.0POWER kW

CASSETTE (600 x 600)KCI-35 DVN10 KCI-52 DVN10

SETS

SUPERSLIM CASSETTE

KCIS-71 DVN10 KCIS-90 DVN10KCIS-105 DVN10

KCIS-105 DTN10KCIS-125 DVN10

KCIS-125 DTN10KCIS-140 DVN10

KCIS-140 DTN10KCIS-52 DVN10 KCIS-160 DTN10

CEILING / FLOOR

KPC-71 DVN10 KPC-90 DVN10KPC-105 DVN10

KPC-105 DTN10KPC-125 DVN10

KPC-125 DTN10KPC-140 DVN10

KPC-140 DTN10KPC-52 DVN10 KPC-160 DTN10

DUCTS

KPD-71 DVN10 KPD-90 DVN10KPD-105 DVN10

KPD-105 DTN10KPD-125 DVN10

KPD-125 DTN10KPD-140 DVN10

KPD-140 DTN10KPD-52 DVN10KPD-35 DVN10 KPD-160 DTN10

Go back to General Contents Go back to ZENaxial Index(Index)

82

COMMERCIAL RANGE SETS - AXIAL

CASSETTE ART FLUX 360º (600x600)

TECHNICAL SPECIFICATIONS

*Sound pressure at low speed.

**Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres.

*** Except for 35 (3.5 kW) models.

Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

SET KCI-35 DVN10 KCI-52 DVN10Cooling capacity (min./rated/max.) kW 0.62/3.52/4.40 0.79/5.28/6.15

Cooling capacity (min./rated/max.) Kcal/h 533/3027/3783 679/4540/5288

Cooling input (min./rated/max.) kW 0.210/0.960/1.692 0.270/1.630/2.365

SEER 6.1 6.3

Cooling energy class A++ A++

Heating capacity (min./rated/max.) kW 0.62/4.10/5.13 0.88/5.57/7.03

Heating capacity (min./rated/max.) Kcal/h 533/3525/4411 757/4789/6045

Heating input (min./rated/max.) kW 0.496/0.995/1.830 0.295/1.500/2.510

SCOP 4.0 4.0

Heating efficiency class A+ A+

Heating capacity -7ºC kW 3.18 4.25

COP -7ºC 3.08 2.77

OUTDOOR UNIT KUE-35 DVN10 KUE-52 DVN10Compressor type Rotary Rotary

Outdoor airflow m3/h 2000 2100

Sound pressure dB (A) 57 56.5

Refrigerant R-410 A R-410 A

Refrigerant charge / Additional charge** gr 1380 / 15 1480 / 15

Liquid pipe diameter mm (inch") ø6.35 (1/4") ø6.35 (1/4")

Gas pipe diameter mm (inch") ø9.52 (3/8") ø12.7 (1/2")

Max. piping length m 25 30

Pipe height difference m 10 20

Width/Height/Depth mm 800/554/333 800/554/333

Net weight Kg 34.5 35.5

Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5

Shielded communication wires*** mm2 (3+T)x2.5 2x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50

INDOOR UNIT KCI-35 DN10 KCI-52 DN10Indoor airflow m3/h 650/530/450 660/550/490

Sound pressure* dB (A) 34 38

Width/Height/Depth mm 570/260/570 570/260/570

Net weight Kg 16 16.5

Width/Height/Depth (panel) mm 647/50/647 647/50/647

Net weight (panel) Kg 2.5 2.5

Power cord mm2 with communication (2+T)x2.5

Shielded communication wires*** mm2 (3+T)x2.5 2x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50

Go back to General Contents (Index) Go back to ZENaxial Index

83

Design and Install for you

ZE

N

AX

IAL

COM

ME

RCI

AL

CONTROLLERS

The Cassette Artflux 360º 600x600 units stands out from other units thanks to its elegant design. Their small dimensions allows them for adapting to false ceiling installations and their 360º airflow provides user with highest comfort and covers every corner of the room.

• Pre-installation for fresh air inlet.

• Standard condensation pump.

• The 5.2 kW unit is compatible with TWINS configuration.

• Compact unit with integrated electric box.

• Voltage-free Alarm and ON/OFF dry contacts.

• 360º airflow

GENERAL CHARACTERISTICS

STANDARD CONDENSATION PUMP+

K01-LON K02-MODBUS K01-BACNET K01-KNXKAYNET CONTROL K01-WIFI

BMS AND SOFTWARE

INDIVIDUAL

For further information, please see our Controllers range

CENTRALISED

KCT-02.1 SRKC-02.1 H KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB

KID-02 S(*) RECOMMENDED

KID-02 S KC-03 SPS KC-01 S

UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you shall add to the € price for the set, the price

difference between the recommended controller and the selected controller.ELIGE TU CONTROL

CHOOSE YOUR CONTROL

PRICE LIST

MOD. SET MOD. INDOOR INDOOR UNIT PRICE MOD. OUTDOOR OUTDOOR UNIT PRICE RECOM. CONTROL SET PRICE

KCI-35 DVN10 KCI-35 DN10 £428 KUE-35 DVN10 £514.36 KID-02 S £943

KCI-52 DVN10 KCI-52 DN10 £496 KUE-52 DVN10 £649.26 KID-02 S £1,145

(*) Price calculation based on the recommended controller.

Go back to General Contents Go back to ZENaxial Index(Index)

84

COMMERCIAL RANGE SETS - AXIAL

ART FLUX 360º CASSETTE SUPERSLIMTECHNICAL SPECIFICATIONS

INDOOR UNIT KCIS-52 DN10 KCIS-71 DN10 KCIS-90 DN10Indoor airflow m3/h 1000/800/700 1450/1250/1100 1700/1460/1300

Sound pressure* dB (A) 37 39 44

Width/Height/Depth mm 840/205/840 840/245/840 840/245/840

Net weight Kg 21.3 24 26.5

Width/Height/Depth (panel) mm 950/55/950 950/55/950 950/55/950

Net weight (panel) Kg 5 5 5

Power cord mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Shielded communication wires mm2 2x1.5 2x1.5 2x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50

*Sound pressure at low speed.

**Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres.

Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

SET KCIS-52 DVN10 KCIS-71 DVN10 KCIS-90 DVN10Cooling capacity (min./rated/max.) kW 0.79/5.28/6.15 1.20/7.03/8.21 2.08/8.79/10.55

Cooling capacity (min./rated/max.) Kcal/h 679/4540/5289 1032/6045/7061 1789/7559/9073

Cooling input (min./rated/max.) kW 0.26/1.68/2.36 0.40/2.17/3.15 0.69/2.76/4.05

SEER 6.3 6.1 6.1

Cooling energy class A++ A++ A++

Heating capacity (min./rated/max.) kW 0.88/5.67/7.03 1.20/7.03/8.65 2.08/9.08/10.52

Heating capacity (min./rated/max.) Kcal/h 757/4876/6046 1032/6045/7439 1789/7809/9047

Heating input (min./rated/max.) kW 0.29/1.46/2.51 0.40/1.90/3.09 0.69/2.38/3.75

SCOP 4.0 4.0 4.0

Heating efficiency class A+ A+ A+

Heating capacity -7ºC kW 4.33 5.13 6.99

COP -7ºC 2.52 2.53 2.50

OUTDOOR UNIT KUE-52 DVN10 KUE-71 DVN10 KUE-90 DVN10Compressor type Rotary Double rotary Double rotary

Outdoor airflow m3/h 2100 2700 4300

Sound pressure dB (A) 56.5 60.5 59.5

Refrigerant R-410 A R-410 A R-410 A

Refrigerant charge / Additional charge** gr 1480 / 15 1950 / 30 2800 / 30

Liquid pipe diameter mm (inch") ø6.35 (1/4") ø9.52 (3/8") ø9.52 (3/8")

Gas pipe diameter mm (inch") ø12.7 (1/2") ø15.9 (5/8") ø15.9 (5/8")

Max. piping length m 30 50 50

Pipe height difference m 20 25 25

Width/Height/Depth mm 800/554/333 845/702/363 946/810/410

Net weight Kg 35.5 49 62.9

Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x4

Shielded communication wires mm2 2x1.5 2x1.5 2x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50

Go back to General Contents (Index) Go back to ZENaxial Index

85

Design and Install for you

ZE

N

AX

IAL

COM

ME

RCI

AL

KCIS-105 DN10

KCIS-105 DN10

KCIS-125 DN10

KCIS-125 DN10

KCIS-140 DN10

KCIS-140 DN10

KCIS-160 DN10

1900/1750/1460 1900/1750/1460 1850/1600/1400 1850/1600/1400 1850/1600/1400 1850/1600/1400 1900/1650/1450

47 47 48 48 45 48 46

840/245/840 840/245/840 840/287/840 840/287/840 840/287/840 840/287/840 840/287/840

25.6 25.6 26.1 26.1 28 28 31

950/55/950 950/55/950 950/55/950 950/55/950 950/55/950 950/55/950 950/55/950

5 5 5 5 5 5 5

(2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5

220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

KCIS-105 DVN10

KCIS-105 DTN10

KCIS-125 DVN10

KCIS-125 DTN10

KCIS-140 DVN10

KCIS-140 DTN10

KCIS-160 DTN10

2.93/10.55/12.09 2.93/10.55/12.02 3.22/12.31/13.19 3.22/12.31/13.19 3.99/13.78/16.12 3.99/13.78/16.12 4.98/16.12/18.462520/9073/10397 2520/9073/10337 2769/10586/11343 2769/10586/11343 3431/11851/13863 3431/11851/13863 4282/13863/15875

0.97/4.06/4.62 0.97/4.06/4.62 1.07/4.09/5.07 1.07/4.09/5.07 1.33/5.16/6.20 1.33/5.16/6.20 11.66/6.39/7.10

6.1 6.1 5.6 5.6 5.6 5.6 5.6

A++ A++ A+ A+ A+ A+ A+

2.64/11.13/13.19 2.64/11.13/13.19 2.93/13.48/14.65 3.4/12.89/14.5 4.19/15.53/17.59 4.19/15.53/17.59 5.28/18.17/20.51

2296/9572/11343 2296/9572/11343 2520/11593/12599 2924/11085/12470 3603/13356/15127 3603/13356/15127 4540/15626/17638

0.88/3.08/4.69 0.88/3.08/4.69 0.97/3.53/5.23 0.97/3.53/5.23 1.40/4.55/6.76 1.40/4.55/6.76 1.76/5.73/7.32

4.0 4.0 4.0 4.0 4.0 4.0 4.0

A+ A+ A+ A+ A+ A+ A+

8.76 8.93 9.73 9.73 10.17 10.17 10.17

2.48 2.44 2.47 2.48 2.29 2.60 2.66

KUE-105 DVN10

KUE-105 DTN10

KUE-125 DVN10

KUE-125 DTN10

KUE-140 DVN10

KUE-140 DTN10

KUE-160 DTN10

Double rotary Double rotary Double rotary Double rotary Double rotary Double rotary Double rotary

4300 4300 4300 4300 6800 6800 7200

61 62 62.5 63 65 65 62.5

R-410 A R-410 A R-410 A R-410 A R-410 A R-410 A R-410 A

3200 / 30 3200 / 30 3650 / 30 3650 / 30 4000 / 30 4000 / 30 4300 / 30

ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8")

ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8")

65 65 65 65 65 65 65

30 30 30 30 30 30 30

946/810/410 946/810/410 946/810/410 946/810/410 952/1333/415 952/1333/415 952/1333/415

67.2 78.9 70.5 85 95.1 108.1 112.8

(2+T)x4 (4+T)x2.5 (2+T)x4 (4+T)x2.5 (2+T)x6 (4+T)x4 (4+T)x6

2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5

220-240/1/50 380-400/3/50 220-240/1/50 380-400/3/50 220-240/1/50 380-400/3/50 380-400/3/50

Go back to General Contents Go back to ZENaxial Index(Index)

86

COMMERCIAL RANGE SETS - AXIAL

ART FLUX 360º CASSETTE SUPERSLIM

• Fresh air inlet (optional).

• Standard condensation pump.

• Units 52, 71 and 90 are compatible with TWINS configuration.

• Louvres position memory.

• Slim design compact unit.

• Voltage-free Alarm and ON/OFF dry contacts.

• 360º airflow.

• KC-03 SPS controller, for independent vane control.

• Side air outlet for a duct (optional).

GENERAL CHARACTERISTICS

CONTROLLERS

K01-LON K02-MODBUS K01-BACNET K01-KNXKAYNET CONTROL K01-WIFI

BMS AND SOFTWARE

INDIVIDUAL

For further information, please see our Controllers range

CENTRALISED

KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB

PRICE CALCULATION BASED ON

THE RECOMMENDED CONTROLLER

If you want a different controller, you shall add to

the € price for the set, the price difference between the

recommended controller and the selected controller.

KID-02 S KC-03 SPS

The KAYSUN UK Cassette type units are fitted with a 360º air diffusion system that allows them to reach every corner of the room and provide maximum comfort to users. They have an impeccable appearance, a compact structure and a slim design to adapt to spaces with low ceilings.

ELIGE TU CONTROL

CHOOSE YOUR CONTROL

Go back to General Contents (Index) Go back to ZENaxial Index

87

Design and Install for you

ZE

N

AX

IAL

COM

ME

RCI

AL

STANDARD CONDENSATION PUMP+

KID-02 S(*) RECOMMENDED

OPTIONALMOTORIZED PANEL

If you want the motorised panel

you will also need the KC-03 SPS control

TWINS COMBINATIONS (OPTIONAL)+

PRICE LIST

MOD. SET MOD. INDOORINDOOR UNIT

PRICEMOD. OUTDOOR

OUTDOOR UNIT PRICE

RECOM. CONTROL SET PRICE

KCIS-52 DVN10 KCIS-52 DN10 £510 KUE-52 DVN10 £649 KID-02 S £1,043

KCIS-71 DVN10 KCIS-71 DN10 £603 KUE-71 DVN10 £896 KID-02 S £1,350

KCIS-90 DVN10 KCIS-90 DN10 £763 KUE-90 DVN10 £1,014 KID-02 S £1,600

KCIS-105 DVN10 KCIS-105 DN10 £776 KUE-105 DVN10 £1,321 KID-02 S £1,677

KCIS-105 DTN10 KCIS-105 DN10 £776 KUE-105 DTN10 £1,437 KID-02 S £1,770

KCIS-125 DVN10 KCIS-125 DN10 £795 KUE-125 DVN10 £1,521 KID-02 S £1,853

KCIS-125 DTN10 KCIS-125 DN10 £795 KUE-125 DTN10 £1,596 KID-02 S £1,913

KCIS-140 DVN10 KCIS-140 DN10 £814 KUE-140 DVN10 £1,761 KID-02 S £2,060

KCIS-140 DTN10 KCIS-140 DN10 £814 KUE-140 DTN10 £1,761 KID-02 S £2,060

KCIS-160 DTN10 KCIS-160 DN10 £851 KUE-160 DTN10 £1,925 KID-02 S £2,222

(*) Price calculation based on the recommended controller.

Go back to General Contents Go back to ZENaxial Index(Index)

88

COMMERCIAL RANGE SETS - AXIAL

CEILING / FLOORTECHNICAL SPECIFICATIONS

SET KPC-52 DVN10 KPC-71 DVN10 KPC-90 DVN10Cooling capacity (min./rated/max.) kW 0.79/5.28/6.15 1.2/7.03/8.21 2.08/8.79/10.55

Cooling capacity (min./rated/max.) Kcal/h 679/4541/5289 1032/6046/7061 1789/7559/9073

Cooling input (min./rated/max.) kW 0.27/1.63/2.37 0.4/2.29/3.16 0.69/2.96/4.06

SEER 6.5 6.1 6.1

Cooling energy class A++ A++ A++

Heating capacity (min./rated/max.) kW 0.88/5.67/7.03 1.2/7.03/8.65 2.08/9.38/10.84

Heating capacity (min./rated/max.) Kcal/h 757/4876/6046 1032/6046/7439 1789/8067/9322

Heating input (min./rated/max.) kW 0.26/1.46/2.51 0.4/1.9/3.09 0.69/2.48/3.87

SCOP 4.0 4.0 4.0

Heating efficiency class A+ A+ A+

Heating capacity -7ºC kW 4.33 5.13 7.25

COP -7ºC 2.61 2.64 2.53

OUTDOOR UNIT KUE-52 DVN10 KUE-71 DVN10 KUE-90 DVN10Compressor type Rotary Double rotary Double rotary

Outdoor airflow m3/h 2100 2700 4300

Sound pressure dB (A) 56.5 60.5 59.5

Refrigerant R-410 A R-410 A R-410 A

Refrigerant charge / Additional charge** gr 1480 / 15 1950 / 30 2800 / 30

Liquid pipe diameter mm (inch") ø6.35 (1/4") ø9.52 (3/8") ø9.52 (3/8")

Gas pipe diameter mm (inch") ø12.7 (1/2") ø15.9 (5/8") ø15.9 (5/8")

Max. piping length m 30 50 50

Pipe height difference m 20 25 25

Width/Height/Depth mm 800/554/333 845/702/363 946/810/410

Net weight Kg 35.5 49 62.9

Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x4

Shielded communication wires mm2 2x1.5 2x1.5 2x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50

INDOOR UNIT KPC-52 DN10 KPC-71 DN10 KPC-90 DN10Indoor airflow m3/h 900/800/700 1180/1050/850 1650/1450/1250

Sound pressure* dB (A) 34 42 44

Width/height/depth (ceiling installation) mm 1068/235/675 1068/235/675 1285/235/675

Net weight Kg 25.8 25 31

Power cord mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Shielded communication wires mm2 2x1.5 2x1.5 2x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50

*Sound pressure at low speed.

**Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres.

Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

Go back to General Contents (Index) Go back to ZENaxial Index

89

Design and Install for you

ZE

N

AX

IAL

COM

ME

RCI

AL

KUE-105 DVN10 KUE-105 DTN10 KUE-125 DVN10 KUE-125 DTN10 KUE-140 DVN10 KUE-140 DTN10 KUE-160 DTN10Double rotary Double rotary Double rotary Double rotary Double rotary Double rotary Double rotary

4300 4300 4300 4300 6800 6800 7200

61 62 62.5 63 65 65 62.5

R-410 A R-410 A R-410 A R-410 A R-410 A R-410 A R-410 A

3200 / 30 3200 / 30 3650 / 30 3650 / 30 4000 / 30 4000 / 30 4300 / 30

ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8")

ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8")

65 65 65 65 65 65 65

30 30 30 30 30 30 30

946/810/410 946/810/410 946/810/410 946/810/410 952/1333/415 952/1333/415 952/1333/415

67.2 78.9 70.5 85 95.1 108.1 112.8

(2+T)x4 (4+T)x2.5 (2+T)x4 (4+T)x2.5 (2+T)x6 (4+T)x4 (4+T)x6

2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5

220-240/1/50 380-400/3/50 220-240/1/50 380-400/3/50 220-240/1/50 380-400/3/50 380-400/3/50

KPC-105 DN10 KPC-105 DN10 KPC-125 DN10 KPC-125 DN10 KPC-140 DN10 KPC-140 DN10 KPC-160 DN102048/1767/1403 2048/1767/1403 2271/1886/1394 2100/1800/1400 2100/1800/1400 2100/1800/1400 2250/1660/1280

40 40 43 41 41 41 45

1650/235/675 1650/235/675 1650/235/675 1650/235/675 1650/235/675 1650/235/675 1650/235/675

40.3 40.3 40.5 40.5 38.2 38.2 40.5

(2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5

220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

KPC-105 DVN10 KPC-105 DTN10 KPC-125 DVN10 KPC-125 DTN10 KPC-140 DVN10 KPC-140 DTN10 KPC-160 DTN102.93/10.55/12.02 2.93/10.55/12.02 3.22/12.31/13.19 3.22/12.31/13.19 4.1/14.07/16.41 4.1/14.07/16.41 4.98/15.82/18.11

2520/9073/10337 2520/9073/10337 2769/10587/11343 2769/10587/11343 3526/12100/14113 3526/12100/14113 4283/13605/15575

0.98/4.06/4.62 0.98/4.06/4.62 1.07/4.23/5.07 1.07/4.23/5.07 1.37/5.19/6.31 1.37/5.19/6.31 1.66/6.06/6.97

6.3 6.1 6.1 6.1 6.1 6.1 6.1

A++ A++ A++ A++ A++ A++ A++

2.64/11.13/13.19 2.64/11.13/13.19 3/13.5/14.7 2.84/12.9/14.01 4.4/16.41/18.46 4.4/16.41/18.46 5.28/18.17/20.51

2270/9572/11343 2270/9572/11343 2580/11610/12642 2442/11103/12049 3784/14113/15876 3784/14113/15876 4541/15626/17639

0.88/2.99/4.69 0.88/2.99/4.69 0.95/3.54/5 0.95/3.39/5 1.47/4.81/6.59 1.47/4.81/6.59 1.76/5.65/7.32

4.0 4.0 4.0 4.0 4.0 4.0 4.0

A+ A+ A+ A+ A+ A+ A+

9.29 9.11 9.73 9.73 10.44 10.44 10.62

2.48 2.43 2.61 2.73 2.54 2.71 2.76

Go back to General Contents Go back to ZENaxial Index(Index)

90

COMMERCIAL RANGE SETS - AXIAL

CEILING / FLOOR

KAYSUN UK Zen range makes air conditioning at your disposal through its most versatile product, the Ceiling/Floor units. Compact and state-of-the-art design that integrates into every room environment. A simple and, at the same time, versatile unit.

• Easy access to components for maintenance.

• Floor or ceiling installation.

• New numerical display in the receiver.

• Improved airflow for a greater comfort.

• Voltage-free Alarm and ON/OFF dry contacts.

• KC-03 SPS wired controller (optional).

GENERAL CHARACTERISTICS

CONTROLLERS

BMS AND SOFTWARE

INDIVIDUAL

For further information, please see our Controllers range

CENTRALISED

KCT-02.1 SR KCC-16 KCCT-64 I KCC-64 I-PSKC-02.1 H KCC-64 WEB

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you should add to the € price for the set the price difference

between recommended controller and the selected controller.

KID-02 S KC-03 SPS KC-01 S

ELIGE TU CONTROL

CHOOSE YOUR CONTROL

Go back to General Contents (Index) Go back to ZENaxial Index

91

Design and Install for you

ZE

N

AX

IAL

COM

ME

RCI

AL

KID-02 S(*) RECOMMENDED

Enquire about availability and price.

ALARM AND VOLTAGE-FREE CONTACTS +

CEILING/FLOOR COMPATIBLE +

PRICE LIST

MOD. SET MOD. INDOORINDOOR UNIT

PRICEMOD. OUTDOOR

OUTDOOR UNIT PRICE

RECOM. CONTROL SET PRICE

KPC-52 DVN10 KPC-52 DN10 £552 KUE-52 DVN10 £649 KID-02 S £1,201

KPC-71 DVN10 KPC-71 DN10 £601 KUE-71 DVN10 £896 KID-02 S £1,498

KPC-90 DVN10 KPC-90 DN10 £705 KUE-90 DVN10 £1,014 KID-02 S £1,719

KPC-105 DVN10 KPC-105 DN10 £720 KUE-105 DVN10 £1,321 KID-02 S £2,042

KPC-105 DTN10 KPC-105 DN10 £720 KUE-105 DTN10 £1,437 KID-02 S £2,157

KPC-125 DVN10 KPC-125 DN10 £721 KUE-125 DVN10 £1,521 KID-02 S £2,242

KPC-125 DTN10 KPC-125 DN10 £721 KUE-125 DTN10 £1,596 KID-02 S £2,317

KPC-140 DVN10 KPC-140 DN10 £755 KUE-140 DVN10 £1,761 KID-02 S £2,516

KPC-140 DTN10 KPC-140 DN10 £755 KUE-140 DTN10 £1,761 KID-02 S £2,516

KPC-160 DTN10 KPC-160 DN10 £769 KUE-160 DTN10 £1,925 KID-02 S £2,695

(*) Price calculation based on the recommended controller.

Go back to General Contents Go back to ZENaxial Index(Index)

92

COMMERCIAL RANGE SETS - AXIALCompatible con

DUCTSTECHNICAL SPECIFICATIONS

POWER CONSUMPTION KPD-35 DVN10 KPD-52 DVN10 KPD-71 DVN10 KPD-90 DVN10Cooling capacity (min./rated/max.) kW 0.62/3.52/4.4 0.79/5.28/6.15 1.2/7.03/8.21 2.08/8.79/10.55

Cooling capacity (min./rated/max.) Kcal/h 533/3027/3784 679/4541/5289 1032/6046/7061 1789/7559/9073

Cooling input (min./rated/max.) kW 0.21/1.03/1.69 0.26/1.69/2.37 0.4/2.29/3.16 0.69/2.88/4.06

SEER 6.1 6.5 6.1 6.1

Cooling energy class A++ A++ A++ A++

Heating capacity (min./rated/max.) kW 0.62/3.81/4.98 0.88/5.67/7.03 1.2/7.03/8.65 2.08/9.38/10.84

Heating capacity (min./rated/max.) Kcal/h 533/3277/4283 757/4876/6046 1032/6046/7439 1789/8067/9322

Heating input (min./rated/max.) kW 0.5/1/1.79 0.29/1.46/2.51 0.4/1.9/3.09 0.69/2.46/3.87

SCOP 4.0 4.0 4.0 4.0

Heating efficiency class A+ A+ A+ A+

Heating capacity -7ºC kW 2.92 4.16 5.13 7.25

COP -7ºC 2.57 2.51 2.68 2.6

OUTDOOR UNIT KUE-35 DVN10 KUE-52 DVN10 KUE-71 DVN10 KUE-90 DVN10Compressor type Rotary Rotary Double rotary Double rotary

Outdoor airflow m3/h 2000 2100 2700 4300

Sound pressure dB (A) 57 56.5 60.5 59.5

Refrigerant R-410 A R-410 A R-410 A R-410 A

Refrigerant charge / Additional charge**

gr 1380 / 15 1480 / 15 1950 / 30 2800 / 30

Liquid pipe diameter mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8") ø9.52 (3/8")

Gas pipe diameter mm (Inch) ø9.52 (3/8") ø12.7 (1/2") ø15.9 (5/8") ø15.9 (5/8")

Max. piping length m 25 30 50 50

Pipe height difference m 10 20 25 25

Width/Height/Depth mm 800/554/333 800/554/333 845/702/363 946/810/410

Net weight Kg 34.5 35.5 49 62.9

Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x4

Shielded communication wires*** mm2 (3+T)x2.5 2x1.5 2x1.5 2x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

INDOOR UNIT KPD-35 DN10 KPD-52 DN10 KPD-71 DN10 KPD-90 DN10Indoor airflow m3/h 640/550/470 1000/900/750 1480/1300/1090 1720/1500/1230

Static pressure range (rated) Pa 0-45 (25) 0-100 (80) 0-100 (80) 0-100 (80)

Sound pressure* dB (A) 35 37 38 44

Width/Height/Depth mm 700/210/635 920/270/635 920/270/635 1140/270/775

Net weight Kg 18 27 28 35

Power cord mm2 with communication (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Shielded communication wires*** mm2 (3+T)x2.5 2x1.5 2x1.5 2x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

*Sound pressure at low speed. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres.

Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

*** Except for 3.5 kW units.

Go back to General Contents (Index) Go back to ZENaxial Index

93

Design and Install for you

ZE

N

AX

IAL

COM

ME

RCI

AL

KUE-105 DVN10 KUE-105 DTN10 KUE-125 DVN10 KUE-125 DTN10 KUE-140 DVN10 KUE-140 DTN10 KUE-160 DTN10Double rotary Double rotary Double rotary Double rotary Double rotary Double rotary Double rotary

4300 4300 4300 4300 6800 6800 7200

61 62 62.5 63 65 65 62.5

R-410 A R-410 A R-410 A R-410 A R-410 A R-410 A R-410 A

3200 / 30 3200 / 30 3650 / 30 3650 / 30 4000 / 30 4000 / 30 4300 / 30

ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8")

ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8") ø15.9 (5/8")

65 65 65 65 65 65 65

30 30 30 30 30 30 30

946/810/410 946/810/410 946/810/410 946/810/415 952/1333/415 952/1333/415 952/1333/415

67.2 78.9 70.5 85 95.1 108.1 112.8

(2+T)x4 (4+T)x2.5 (2+T)x4 (4+T)x2.5 (2+T)x6 (4+T)x4 (4+T)x6

2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5

220-240/1/50 380-400/3/50 220-240/1/50 380-400/3/50 220-240/1/50 380-400/3/50 380-400/3/50

KPD-105 DN10 KPD-105 DN10 KPD-125 DN10 KPD-125 DN10 KPD-140 DN10 KPD-140 DN10 KPD-160 DN101750/1500/1280 1750/1500/1280 2200/1900/1600 2200/1900/1600 2200/1900/1600 2200/1900/1600 2200/1900/1600

0-100 (80) 0-100 (80) 0-100 (80) 0-100 (80) 0-100 (80) 0-100 (80) 0-100 (80)

40 40 44 44 45 45 45

1200/300/865 1200/300/865 1200/300/865 1200/300/865 1200/300/865 1200/300/865 1200/300/865

45 45 43.4 43.4 43.2 43.2 43.1

(2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5 2x1.5

220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

KPD-105 DVN10 KPD-105 DTN10 KPD-125 DVN10 KPD-125 DTN10 KPD-140 DVN10 KPD-140 DTN10 KPD-160 DTN102.93/10.55/12.02 2.93/10.55/12.02 3.22/12.31/13.19 3.22/12.31/13.19 4.1/14.07/16.41 4.1/14.07/16.41 4.98/15.82/18.11

2520/9073/10337 2520/9073/10337 2769/10587/11343 2769/10587/11343 3526/12100/14113 3526/12100/14113 4283/13605/15575

0.98/3.97/4.62 0.98/3.97/4.62 1.07/4.09/5.07 1.07/4.09/5.07 1.37/5.12/6.31 1.37/5.12/6.31 1.66/5.26/6.97

6.3 6.1 5.6 5.6 6.1 6.1 6.1

A++ A++ A+ A+ A++ A++ A++

2.64/11.13/13.19 2.64/11.13/13.19 2.93/13.48/14.65 2.93/13.48/14.65 4.34/16.12/18.13 4.34/16.12/18.13 5.28/18.17/20.51

2270/9575/11343 2270/9575/11343 2520/11593/12599 2520/11593/12599 3732/13863/15592 3732/13863/15592 4541/15626/17639

0.88/2.92/4.69 0.88/2.92/4.69 0.98/3.54/5.23 0.98/3.54/5.23 1.45/4.36/6.48 1.45/4.36/6.48 1.76/5.03/7.32

4.0 4.0 4.0 4.0 4.0 4.0 4.0

A+ A+ A+ A+ A+ A+ A+

9.29 9.29 9.73 9.73 10.79 10.79 10.88

2.56 2.56 2.75 2.78 2.77 2.71 2.86

Go back to General Contents Go back to ZENaxial Index(Index)

94

COMMERCIAL RANGE SETS - AXIALCompatible con

DUCTS

KAYSUN UK ducts units offer a wide range of features, which turns them into one of the best products in the market. These units can be easily installed in small spaces, such as compact suspended ceilings, thanks to the tilted position of their battery, which provides them with a slim design.

GENERAL CHARACTERISTICS

CONTROLLERS

K01-LON K02-MODBUS K01-BACNET K01-KNXKAYNET CONTROL K01-WIFI

BMS AND SOFTWARE

INDIVIDUAL

For further information, please see our Controllers range

CENTRALISED

KCT-02.1 SRKC-02.1 H KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you should add to the € price for the set the price difference

between recommended controller and the selected controller.

• Easily removable filter.

• Air supply duct and return air duct pre-installation frames.

• Double possibility for air inlet (rear or lower intake).

• Fresh air intake at a side of the unit.

• Voltage-free Alarm and ON/OFF dry contacts.

• Standard condensation pump of up to 750 mm in height.

• Electric box removable up to 1 metre apart from the unit's

body.

• Up to 100 Pa available depending on the model.

KID-02 S KC-03 SPS KC-01 S

ELIGE TU CONTROL

CHOOSE YOUR CONTROL

Go back to General Contents (Index) Go back to ZENaxial Index

95

Design and Install for you

ZE

N

AX

IAL

COM

ME

RCI

AL

KC-03 SPS

(*) RECOMMENDED

Compatible with

STANDARD CONDENSATION PUMP, up to 750 mm IN HEIGHT+

ALARM AND VOLTAGE-FREE CONTACTS +

Enquire about availability and price.

PRICE LIST

MOD. SET MOD. INDOORINDOOR UNIT

PRICEMOD. OUTDOOR

OUTDOOR UNIT PRICE

RECOM. CONTROL SET PRICE

KPD-35 DVN10 KPD-35 DN10 £346 KUE-35 DVN10 £514 KC-03 SPS £861

KPD-52 DVN10 KPD-52 DN10 £347 KUE-52 DVN10 £649 KC-03 SPS £996

KPD-71 DVN10 KPD-71 DN10 £375 KUE-71 DVN10 £896 KC-03 SPS £1,272

KPD-90 DVN10 KPD-90 DN10 £545 KUE-90 DVN10 £1,014 KC-03 SPS £1,559

KPD-105 DVN10 KPD-105 DN10 £548 KUE-105 DVN10 £1,321 KC-03 SPS £1,870

KPD-105 DTN10 KPD-105 DN10 £548 KUE-105 DTN10 £1,437 KC-03 SPS £1,985

KPD-125 DVN10 KPD-125 DN10 £567 KUE-125 DVN10 £1,521 KC-03 SPS £2,088

KPD-125 DTN10 KPD-125 DN10 £567 KUE-125 DTN10 £1,596 KC-03 SPS £2,163

KPD-140 DVN10 KPD-140 DN10 £681 KUE-140 DVN10 £1,761 KC-03 SPS £2,442

KPD-140 DTN10 KPD-140 DN10 £681 KUE-140 DTN10 £1,761 KC-03 SPS £2,442

KPD-160 DTN10 KPD-160 DN10 £718 KUE-160 DTN10 £1,925 KC-03 SPS £2,644

(*) Price calculation based on the recommended controller.

Go back to General Contents Go back to ZENaxial Index(Index)

96

COMMERCIAL RANGE SETS - GRAPHICS OF DUCTCompatible con

DUCTS STATIC PRESSURE GRAPHS

KPD-35 DN10

KPD-52 DN10

Airflow (m3/h) Airflow (m3/h) Airflow (m3/h)

High Medium Low

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

Airflow (m3/h) Airflow (m3/h) Airflow (m3/h)

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

High Medium Low

Go back to General Contents (Index) Go back to ZENaxial Index

97

Design and Install for you

ZE

N

AX

IAL

COM

ME

RCI

AL

KPD-90 DN10

KPD-71 DN10

Airflow (m3/h) Airflow (m3/h) Airflow (m3/h)

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

Airflow (m3/h) Airflow (m3/h) Airflow (m3/h)

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

High Medium Low

High Medium Low

Go back to General Contents Go back to ZENaxial Index(Index)

98

COMMERCIAL RANGE SETS - GRAPHICS OF DUCTCompatible con

DUCTS STATIC PRESSURE GRAPHS

Airflow (m3/h) Airflow (m3/h) Airflow (m3/h)

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

KPD-105 DN10

KPD-125 DN10

Airflow (m3/h) Airflow (m3/h) Airflow (m3/h)

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

High Medium Low

High Medium Low

Go back to General Contents (Index) Go back to ZENaxial Index

99

Design and Install for you

ZE

N

AX

IAL

COM

ME

RCI

AL

Airflow (m3/h) Airflow (m3/h) Airflow (m3/h)

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

KPD-140 DN10

KPD-160 DN10

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

High Medium Low

High Medium Low

Go back to General Contents Go back to ZENaxial Index(Index)

100

COMMERCIAL RANGE TWINS

TWINS

The balance in the Zen range results in good service and greater comfort for users and installers.

Zen Inverter units are fitted with a specific electronic board that allows for connecting two indoor units to the same outdoor unit.

TWIN technology can be applied to compact Cassette 600x600, Art Flux 360º SuperSlim Cassette, ducts and Ceiling/Floor units. Furthermore, sets of different indoor units can be made; i.e, you can combine, for example, a duct unit with a ceiling/floor type unit, among many other possibilities, provided that both indoor units are the same capacity.

The capacities with which you can arrange Twins combinations are the following:- Outdoor unit of 10.5kW with two indoor units of 5.2kW- Outdoor unit of 14.0kW with two indoor units of 7.1kW- Outdoor unit of 17.6kW with two indoor units of 9.0kW

Twins units represent the versatility and balance of the Zen range, and are presented as an option for commercial spaces that require more than one indoor unit to achieve a suitable air-conditioning without demanding more outdoor units.

PIPE DISTANCE

Maximum distance (L+L1+L2)

52+52 indoor combination (A+B) 50 m.

71+71 indoor combination (A+B) 65 m.

90+90 indoor combination (A+B) 65 m.

Maximum distance between the branch pipe and the indoor unit (L1 and L2) 15 m.

Maximum difference in length between the branch pipe and the indoor units (L1-L2) 10 m.

LEVEL DIFFERENCEBetween outdoor unit and indoor units 20 m.

Between indoor units (A and B) 0.5 m.

UNIT BUNIT A

OUTDOOR UNIT

L

L1 L2

DIFFERENT TYPES OF INDOOR UNIT CAN BE COMBINEDIn Twins sets, one can choose from two types of indoor unit. You can create your own Twin set by combining the 2 indoor units that suit you best, provided that they have the same capacity.

Maximum height difference between indoor units of a TWIN system: 0.5 metresBranch pipe not included. Add T-type branch pipe or KCMI 112 branch pipe

OUTDOOR UNIT INDOOR UNIT600x600 cassetteSuperSlim cassette

DuctFloor / ceiling

INDOOR UNIT CONTROL

KID-02 SKC-03 SPS

600x600 cassetteSuperSlim cassette

DuctFloor / ceiling

Go back to General Contents (Index) Go back to ZENaxial Index

101

Design and Install for you

ZE

N

AX

IAL

COM

ME

RCI

AL

KID-02 S SUPERSLIM CASSETTE 360º

SUPERSLIM CASSETTE 360º

KID-02 S CASSETTE CASSETTE

x2

x2

CASSETTE 600 x 600

INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE

KCI-52 DN10 KUE-105 DVN10 KID-02 S £2,315

KCI-52 DN10 KUE-105 DTN10 KID-02 S £2,431

SUPERSLIM CASSETTE

INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE

KCIS-52 DN10 KUE-105 DVN10 KID-02 S £2,342

KCIS-52 DN10 KUE-105 DTN10 KID-02 S £2,357

KCIS-71 DN10 KUE-140 DVN10 KID-02 S £2,967

KCIS-71 DN10 KUE-140 DTN10 KID-02 S £2,967

KCIS-90 DN10 KUE-160 DTN10 KID-02 S £3,454

Go back to General Contents Go back to ZENaxial Index(Index)

102

COMMERCIAL RANGE TWINS

TWINS

x2

KC-03 SPS DUCTS DUCTS

DUCTS

INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE

KPD-52 DN10 KUE-105 DVN10 KC-03 SPS £2,016

KPD-52 DN10 KUE-105 DTN10 KC-03 SPS £2,132

KPD-71 DN10 KUE-140 DVN10 KC-03 SPS £2,511

KPD-71 DN10 KUE-140 DTN10 KC-03 SPS £2,511

KPD-90 DN10 KUE-160 DTN10 KC-03 SPS £3,016

Go back to General Contents (Index) Go back to ZENaxial Index

103

Design and Install for you

ZE

N

AX

IAL

COM

ME

RCI

AL

x2

KID-02 S CEILING/FLOOR CEILING/FLOOR

CEILING/FLOOR

INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE

KPC-52 DN10 KUE-105 DVN10 KID-02 S £3,315

KPC-52 DN10 KUE-105 DTN10 KID-02 S £3,431

KPC-71 DN10 KUE-140 DVN10 KID-02 S £4,305

KPC-71 DN10 KUE-140 DTN10 KID-02 S £4,305

KPC-90 DN10 KUE-160 DTN10 KID-02 S £5,045

Go back to General Contents Go back to ZENaxial Index(Index)

ZEN CENTRIFUGAL COMMERCIAL RANGE

Design and Install for you

105

ZENCENTRIFUGAL COMMERCIAL RANGE

INTRODUCTION TO THE PRODUCT RANGE ........................................ ..106

SETS ........................................................................................................ ..108

SUPERSLIM CASSETTE ................................................................... ..110

CEILING/FLOOR ............................................................................... ..112

DUCTS .............................................................................................. ..114

STATIC PRESSURE GRAPHS .................................................... ..116

TWINS .................................................................................................... ..118

SUPERSLIM CASSETTE ................................................................... ..119

CEILING/FLOOR ............................................................................... ..119

DUCTS .............................................................................................. ..119

COMMERCIAL RANGE

106

INTRODUCTION TO THE RANGE OF PRODUCTS

CENTRIFUGAL COMMERCIAL RANGE

ZEN

We present the KAYSUN UK commercial range with centrifugal outdoor ventilators. The main characteristic of this range that we wish to highlight is its adaptability: it is a machine ideal for installation in indoor spaces, where there is no space for an outdoor axial unit outside.

The combinations with outdoor centrifugal units are pieces of equipment with a compressor and indoor ventilators with DC Inverter technology. These units with a centrifugal ventilator embody one of our key principles (versatility) and have been created to provide a customised solution that is suited to the need to integrate them into the facade of street premises.

The centrifugal ZEN range contains SuperSlim Cassette (840x840) indoor units, ducts and floor/ceiling units. These units can be installed in a TWINS configuration (one outdoor unit with two indoor units working together).

It could be said that the controls of this range are at the expected height. The KID-02 S, a wireless smart control that can inspect the operation of units and change configuration parameters. In terms of controls we have the KC-03 SPS, which can control up to 16 indoor units. Furthermore, it should be pointed out that this year some models in this range will have optional Wi-Fi control.

SMART CONTROLLERS

KAYSUN’s ZEN range has a range of controls at altitude. The cable and wireless controls have the most technologically-advanced functions and utilities, but with a modern and avant-garde aesthetic.

CENTRIFUGAL OUTDOOR UNITS

The centrifugal outdoor units offered by KAYSUN UK are a highly recommended option for systems where there is no outdoor space for installation.

14 AND 16 KW+FLEXIBLE CONFIGURATION CONDENSATION AIR INLET AND OUTLET+60 PA AVAILABLE PRESURE+

INSTALLATION PARAMETRES MODIFICATION+OPERATION PARAMETERS CHECKING+

WEEKLY TIMER+

FOLLOW ME+FOLLOW ME+

UP TO 16 INDOOR UNITS+

KC-03 SPS KID-02 S

“HIGH COMMERCIAL EQUIPMENT”

Go back to General Contents Go back to ZEN centrifugal Index(Index)

Design and Install for you

107

ZE

N

CEN

TRIF

UGA

L CO

MM

ERCI

AL

DUCT UNIT

With regard to the semi-industrial indoor units of the ZEN RANGE, we would like to highlight the Duct unit. We believe that this is one of the most comprehensive units in the market due to the great amount of options and functions included, such as:

• Removable filter (it can be extracted without touching the unit).

• Frame for the air inlet.• Frame for the air outlet.• Double possibility of air inlet (rear outlet or lower outlet).• Condensation pump.• Pre-installation for fresh air inlet.

• Electric box removable up to 1 metre apart from the unit's body.

• Voltage-free Alarm and ON/OFF dry contacts.• Switch to adapt the unit to the duct and to adjust the

flow required by the installation.• Up to 100 Pa available depending on the model.

TWO COMMUNICATION WIRESThe ZEN range units only require two shielded wires without polarity for the communication among units. This new characteristic makes the communication wiring works cheaper and easier.

WIFI ADAPTORIn 2017, KAYSUN UK will unveil its new optional adaptor for units in the ZEN range. These accessories connect the unit to our domestic WiFi network and control it through an App installed on our smartphone. The application also includes a weekly timer built into the App to ease and improve the control

function of our air-conditioning system.

S1

S1

S2

S2

NEW

Go back to General Contents Go back to ZEN centrifugal Index(Index)

COMMERCIAL RANGE SETS - CENTRIFUGAL

108

SETSCENTRIFUGAL

Design and Install for you

109

ZE

N

CEN

TRIF

UGA

L CO

MM

ERCI

AL

3.5 5.2 7.1 9.0 10.5 12.5 14.0 16.0POWER kW

SETS

SUPERSLIM CASSETTE

KCISC-160 DTN10KCISC-140 DTN10

CEILING/FLOOR

KPCC-160 DTN10KPCC-140 DTN10

DUCTS

KPDC-160 DTN10KPDC-140 DTN10

Go back to General Contents Go back to ZEN centrifugal Index(Index)

COMMERCIAL RANGE SETS - CENTRIFUGAL

110

ART FLUX 360º CASSETTE SUPERSLIM

TECHNICAL SPECIFICATIONS

*Sound pressure at low speed.

**Factory pre-charge for 5 metres installations / Additional charge per metre added after 5 metres.

Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

SET KCISC-140 DTN10 KCISC-160 DTN10Cooling capacity kW 12.6 16.11

Cooling capacity Kcal/h 10836 13855

Cooling input kW 5.49 6.76

EER 2.29 2.38

Cooling energy class F F

Heating capacity kW 12.89 16.99

Heating capacity Kcal/h 11085 14611

Heating input kW 4.67 6.13

COP 2.75 2.76

Heating efficiency class E E

Heating capacity -7ºC kW 9 11

COP -7ºC 2.16 2.14

OUTDOOR UNIT KUEC-140 DTN10 KUEC-160 DTN10Compressor type Scroll Scroll

Outdoor airflow/Static pressure m3/h / Pa 3600/60 3600/60

Sound pressure dB (A) 64 64

Refrigerant R-410 A R-410 A

Refrigerant charge / Additional charge** gr 4300/30 4300/30

Liquid pipe diameter mm (inch") ø9.52 (3/8") ø9.52 (3/8")

Gas pipe diameter mm (inch") ø15.9 (5/8") ø15.9 (5/8")

Max. piping length m 65 65

Pipe height difference m 30 30

Width/Height/Depth mm 1394/568/783 1394/568/783

Net weight Kg 177 177

Power cord (10 m max.) mm2 (4+T)x4 (4+T)x4

Shielded communication wires mm2 2x1.5 2x1.5

Power supply V / F / Hz 380-400/3/50 380-400/3/50

INDOOR UNIT KCIS-140 DN10 KCIS-160 DN10Indoor airflow m3/h 1850/1600/1400 1900/1650/1450

Sound pressure* dB (A) 48 46

Width/Height/Depth mm 840/287/840 840/287/840

Net weight Kg 28 31

Width/Height/Depth (panel) mm 950/55/950 950/55/950

Net weight (panel) Kg 5 5

Power cord mm2 (2+T)x2.5 (2+T)x2.5

Shielded communication wires mm2 2x1.5 2x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50

Go back to General Contents (Index) Go back to ZEN centrifugal Index

Design and Install for you

111

ZE

N

CEN

TRIF

UGA

L CO

MM

ERCI

AL

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you should add to the € price for the set the price

difference between recommended controller and the selected controller.

CONTROLLERS

KAYSUN UK centrifugal outdoor units are also compatible with the ArtFlux 360° SuperSlim Cassette units. In order to provide users with maximum comfort, the cassette units are fitted with a 360° air diffusion system that allows them to reach every corner of the room. They have an impeccable appearance, a compact structure and a slim design to adapt to spaces with low ceilings.

• Fresh air inlet (optional).

• Standard condensation pump.

• Louvres position memory.

• KC-03 SPS controller, for independent vane control.

• Slim design compact unit.

• Voltage-free Alarm and ON/OFF dry contacts.

• 360º airflow.

• Side air outlet for a duct (optional).

GENERAL CHARACTERISTICS

K01-LON K02-MODBUS K01-BACNET K01-KNXKAYNET CONTROL K01-WIFI

BMS AND SOFTWARE

INDIVIDUAL

For further information, please see our Controllers range

CENTRALISED

KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB

KID-02 S(*) RECOMMENDED

KID-02 S KC-03 SPS

TWINS COMBINATIONS (OPTIONAL)+

STANDARD CONDENSATION PUMP+

OPTIONALMOTORIZED PANEL

If you want the motorised panel

you will also need the KC-03 SPS control

ELIGE TU CONTROL

CHOOSE YOUR CONTROL

PRICE LIST

MOD. SET MOD. INDOORINDOOR UNIT

PRICEMOD. OUTDOOR

OUTDOOR UNIT PRICE

RECOM. CONTROL SET PRICE

KCISC-140 DTN10 KCIS-140 DN10 £814 KUEC-140 DTN10 £3,339 KID-02 S £4,154

KCISC-160 DTN10 KCIS-160 DN10 £851 KUEC-160 DTN10 £3,525 KID-02 S £4,377

(*) Price calculation based on the recommended controller.

Go back to General Contents Go back to ZEN centrifugal Index(Index)

COMMERCIAL RANGE SETS - CENTRIFUGAL

112

OUTDOOR UNIT KUEC-140 DTN10 KUEC-160 DTN10Compressor type Scroll Scroll

Outdoor airflow/Static pressure m3/h / Pa 3600/60 3600/60

Sound pressure dB (A) 64 64

Refrigerant R-410 A R-410 A

Refrigerant charge / Additional charge** gr 4300 / 30 4300 / 30

Liquid pipe diameter mm (inch") ø9.52 (3/8") ø9.52 (3/8")

Gas pipe diameter mm (inch") ø15.9 (5/8") ø15.9 (5/8")

Max. piping length m 65 65

Pipe height difference m 30 30

Width/Height/Depth mm 1394/568/783 1394/568/783

Net weight Kg 177 177

Power cord (10 m max.) mm2 (4+T)x4 (4+T)x4

Shielded communication wires mm2 2x1.5 2x1.5

Power supply V / F / Hz 380-400/3/50 380-400/3/50

CEILING/FLOORTECHNICAL SPECIFICATIONS

SET KPCC-140 DTN10 KPCC-160 DTN10Cooling capacity kW 13.5 16

Cooling capacity Kcal/h 11610 13760

Cooling input kW 5.885 6.891

EER 2.29 2.32

Cooling energy class F F

Heating capacity kW 14.65 17

Heating capacity Kcal/h 12599 14620

Heating input kW 5.657 6.468

COP 2.58 2.62

Heating efficiency class F E

Heating capacity -7ºC kW 9.82 10.88

COP -7ºC 2.00 2.00

INDOOR UNIT KPC-140 DN10 KPC-160 DN10Indoor airflow m3/h 2100/1800/1400 2250/1660/1280

Sound pressure* dB (A) 41 45

Width/height/depth (ceiling installation) mm 1650/235/675 1650/235/675

Net weight Kg 38.2 40.5

Power cord mm2 (2+T)x2.5 (2+T)x2.5

Shielded communication wires mm2 2x1.5 2x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50

*Sound pressure at low speed.

**Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres.

Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

Go back to General Contents (Index) Go back to ZEN centrifugal Index

Design and Install for you

113

ZE

N

CEN

TRIF

UGA

L CO

MM

ERCI

AL

GENERAL CHARACTERISTICS

KAYSUN UK Zen range makes air conditioning at your disposal through its most versatile product, the Ceiling/Floor units. Compact and state-of-the-art design that integrates into every room environment. A simple and, at the same time, versatile unit compatible with centrifugal outdoor units.

• Easy access to components for maintenance.

• FLOOR or CEILING installation.

• New numerical display in the receiver.

• Improved airflow for a greater comfort.

• Voltage-free Alarm and ON/OFF dry contacts.

• KC-03 SPS wired controller (optional).

ALARM AND VOLTAGE-FREE CONTACTS +

CEILING/FLOOR COMPATIBLE +

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you shall add to the € price for the set, the price

difference between the recommended controller and the selected controller.

CONTROLLERS

BMS AND SOFTWARE

INDIVIDUAL

For further information, please see our Controllers range

CENTRALISED

KCT-02.1 SRKC-02.1 H KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB

K01-LON K02-MODBUS K01-BACNET K01-KNXKAYNET CONTROL K01-WIFI

KID-02 S(*) RECOMMENDED

KC-03 SPSKID-02 S

Enquire about availability and price.

KC-01 S

ELIGE TU CONTROL

CHOOSE YOUR CONTROL

PRICE LIST

MOD. SET MOD. INDOORINDOOR UNIT

PRICEMOD. OUTDOOR

OUTDOOR UNIT PRICE

RECOM. CONTROL SET PRICE

KPCC-140 DTN10 KPC-140 DN10 £755 KUEC-140 DTN10 £3,339.95 KID-02 S £4,095

KPCC-160 DTN10 KPC-160 DN10 £769 KUEC-160 DTN10 £3,525.37 KID-02 S £4,294

(*) Price calculation based on the recommended controller.

Go back to General Contents Go back to ZEN centrifugal Index(Index)

COMMERCIAL RANGE SETS - CENTRIFUGAL

114

DUCTSTECHNICAL SPECIFICATIONS

OUTDOOR UNIT KUEC-140 DTN10 KUEC-160 DTN10Compressor type Scroll Scroll

Outdoor airflow/Static pressure m3/h / Pa 3600/60 3600/60

Sound pressure dB (A) 64 64

Refrigerant R-410 A R-410 A

Refrigerant charge / Additional charge** gr 4300/30 4300/30

Liquid pipe diameter mm (inch") ø9.52 (3/8") ø9.52 (3/8")

Gas pipe diameter mm (inch") ø15.9 (5/8") ø15.9 (5/8")

Max. piping length m 65 65

Pipe height difference m 30 30

Width/Height/Depth mm 1394/568/783 1394/568/783

Net weight Kg 177 177

Power cord (10 m max.) mm2 (4+T)x4 (4+T)x4

Shielded communication wires mm2 2x1.5 2x1.5

Power supply V / F / Hz 380-400/3/50 380-400/3/50

SET KPDC-140 DTN10 KPDC-160 DTN10Cooling capacity kW 13.5 16

Cooling capacity Kcal/h 11610 13760

Cooling input kW 5.483 6.281

EER 2.46 2.54

Cooling energy class E E

Heating capacity kW 14.65 17

Heating capacity Kcal/h 12599 14620

Heating input kW 4.962 5.775

COP 2.95 2.94

Heating efficiency class D D

Heating capacity -7ºC kW 10 12

COP -7ºC 2.31 2.29

INDOOR UNIT KPD-140 DN10 KPD-160 DN10Indoor airflow m3/h 2200/1900/1600 2200/1900/1600

Static pressure range (rated) Pa 0-100 (80) 0-100 (80)

Sound pressure* dB (A) 45 45

Width/Height/Depth mm 1200/300/865 1200/300/865

Net weight Kg 43.2 43.1

Power cord mm2 (2+T)x2.5 (2+T)x2.5

Shielded communication wires mm2 2x1.5 2x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50

*Sound pressure at low speed.

**Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres.

Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

Go back to General Contents (Index) Go back to ZEN centrifugal Index

Design and Install for you

115

ZE

N

CEN

TRIF

UGA

L CO

MM

ERCI

AL

Compatible con

KAYSUN UK ducts units offer a wide range of features, which turns them into one of the best products in the market. These units can be easily installed in small spaces, such as compact suspended ceilings, thanks to the tilted position of their battery, which provides them with a slim design. They are compatible with KAYSUN UK centrifugal outdoor units.

• Easily removable filter.

• Air supply duct and return air duct pre-installation frames.

• Double possibility for air inlet (rear or lower intake).

• Fresh air intake on the side of the unit.

• Voltage-free alarm and ON/OFF dry contacts.

• Electric box removable up to 1 metre apart from the unit's body.

• Up to 100 Pa available depending on the model.

• Standard condensation pump of up to 750 mm in height.

GENERAL CHARACTERISTICS

STANDARD CONDENSATION PUMP, up to 750 mm IN HEIGHT+ALARM AND VOLTAGE-FREE CONTACTS +

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you should add to the € price for the set the price

difference between recommended controller and the selected controller.CONTROLLERS

BMS AND SOFTWARE

INDIVIDUAL

For further information, please see our Controllers range

CENTRALISED

KCT-02.1 SRKC-02.1 H KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB

K01-LON K02-MODBUS K01-BACNET K01-KNXKAYNET CONTROL K01-WIFI

KID-02 S KC-03 SPS

KC-03 SPS

(*) RECOMMENDED

Enquire about availability and price.

KC-01 S

ELIGE TU CONTROL

CHOOSE YOUR CONTROL

PRICE LIST

MOD. SET MOD. INDOORINDOOR UNIT

PRICEMOD. OUTDOOR

OUTDOOR UNIT PRICE

RECOM. CONTROL SET PRICE

KPDC-140 DTN10 KPD-140 DN10 £681 KUEC-140 DTN10 £3,339 KC-03 SPS £4,021

KPDC-160 DTN10 KPD-160 DN10 £718 KUEC-160 DTN10 £3,525 KC-03 SPS £4,244

(*) Price calculation based on the recommended controller.

Go back to General Contents Go back to ZEN centrifugal Index(Index)

COMMERCIAL RANGE

116

GRAPHICS OF DUCT CENTRIFUGAL

DUCTS STATIC PRESSURE GRAPHS

KPD-140 DN10

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

High Medium Low

Airflow (m3/h) Airflow (m3/h) Airflow (m3/h)

Go back to General Contents (Index) Go back to ZEN centrifugal Index

Design and Install for you

117

ZE

N

CEN

TRIF

UGA

L CO

MM

ERCI

AL

Airflow (m3/h) Airflow (m3/h) Airflow (m3/h)

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

Ext

erna

l sta

tic

pres

sure

(Pa)

KPD-160 DN10

High Medium Low

Go back to General Contents Go back to ZEN centrifugal Index(Index)

COMMERCIAL RANGE

118

TWINS

TWINS

The balance of the KAYSUN UK ZEN range results in a good service and comfort for the user and makes life easier for installers. Commercial range units are fitted with a specific electronic board that allows for connecting two indoor units to the same outdoor unit.

The TWIN technology in centrifuges can be applied to the Art Flux 360º Super Slim Cassette, duct units and ceiling/floor units.

Furthermore, sets of different indoor units can be made for example, a duct unit can be combined with a ceiling/floor type

unit, among many other possibilities, provided that both indoor units are the same capacity. The capacities with which you can arrange Twins combinations are the following:

- Outdoor unit of 14kW with two indoor units of 7.1kW- Outdoor unit of 16kW with two indoor units of 9.0kW

Twins represent the versatility and balance of the Zen range, and are presented as an option for commercial spaces that require more than one indoor unit to achieve a suitable air-conditioning without requiring more outdoor units.

PIPE DISTANCE

Maximum distance (L+L1+L2)

71+71 indoor combination (A+B) 65 m.

90+90 indoor combination (A+B) 65 m.

Maximum distance between the branch pipe and the indoor unit (L1 and L2) 15 m.

Maximum difference in length between the branch pipe and the indoor units (L1-L2) 10 m.

LEVEL DIFFERENCEBetween outdoor unit and indoor units 20 m.

Between indoor units (A and B) 0.5 m.

UNIT BUNIT A

OUTDOOR UNIT

L

L1 L2

DIFFERENT TYPES OF INDOOR UNIT CAN BE COMBINEDIn Twins sets, one can choose from two types of indoor unit. You can create your Twin set by combining the 2 indoor units that suit you best, provided that they have the same capacity.

Maximum height difference between indoor units of a TWIN system: 0.5 metresBranch pipe not included. Add T-type branch pipe or KCMI 112 branch pipe

OUTDOOR UNIT

SuperSlim cassetteDuct

Ceiling/floor

CONTROL

KID-02 SKC-03 SPS

SuperSlim cassetteDuct

Ceiling/floor

INDOOR UNIT INDOOR UNIT

Go back to General Contents (Index) Go back to ZEN centrifugal Index

Design and Install for you

119

ZE

N

CEN

TRIF

UGA

L CO

MM

ERCI

AL

KID-02 S FLOOR / CEILING FLOOR / CEILING

KC-03 SPS DUCTS DUCTS

KID-02 S SUPERSLIM CASSETTE 360º

SUPERSLIM CASSETTE 360º

x2

x2

x2

INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE £

KPC-71 DN10 KUEC-140 DTN10 KID-02 S £4,544

KPC-90 DN10 KUEC-160 DTN10 KID-02 S £4,936

CEILING/FLOOR

SUPERSLIM CASSETTE INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE £

KCIS-71 DN10 KUEC-140 DTN10 KID-02S £4,547

KCIS-90 DN10 KUEC-160 DTN10 KID-02 S £5,053

INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE £

KPD-71 DN10 KUEC-140 DTN10 KC-03 SPS £4,090

KPD-90 DN10 KUEC-160 DTN10 KC-03 SPS £4,616

DUCTS

Go back to General Contents Go back to ZEN centrifugal Index(Index)

ZE

N

HIG

H C

APA

CITY

CO

MM

ERCI

AL

ZEN HIGH CAPACITY COMMERCIAL RANGE

Design and Install for you

121

INTRODUCTION TO THE PRODUCT RANGE ....................................... ..122

HIGH-CAPACITY SETS OF DUCTS ....................................................... ..123

AIR-COOLED..................................................................................... ..124

WATER-COOLED.............................................................................. ..128

STATIC PRESSURE GRAPHS ........................................................... ..130

ZENHIGH CAPACITY COMMERCIAL RANGE

COMMERCIAL RANGE

122

We present the high-capacity commercial range. The main characteristics we wish to highlight in this range are its vast cooling capacity and large airflows. These machines are ideal for climate control in large spaces.

Most of these combinations are equipment with a compressor, outdoor ventilators and indoor ventilators with DC Inverter technology, resulting in efficiency and energy savings.

Basically, we have 6 capacity levels of indoor units that range from 20 to 56 kW, and which can be combined with different types of the outdoor unit: side air discharge, top air discharge and watercooled.

INTRODUCTION TO THE RANGE OF PRODUCTS

HIGH CAPACITY COMMERCIAL RANGE

ZEN

“HIGH-PERFORMANCE COMMERCIAL EQUIPMENT”

SIDE AIR DISCHARGE TOP AIR DISCHARGE WATERCOOLED

STATIC PRESSURE OF UP TO 200 PA+LARGE AIRFLOWS+

OUTDOOR UNITS

The high-capacity commercial range contains three different types of outdoor unit, ensuring perfect adaptability to each different type of installation:

LITTLE INSTALLATION SPACE+ EXTREMELY COMPACT+STATIC PRESSURE AVAILABLE 40 PA+ACTUAL LENGTH OF UP TO 175 METRES+TWIN ROTARY COMPRESSORS+ INDOOR INSTALLATION+

LARGE AIRFLOWS

Duct units in the high-capacity commercial range are made up of indoor units of ducts with large airflows at high static pressure levels.

Go back to General Contents Go back to ZEN high capacity Index(Index)

Design and Install for you

123

ZE

N

HIG

H C

APA

CITY

CO

MM

ERCI

AL

20.0 25.0 28.0 40.0 45.0 56.0POWER kW

AIRCOOLED SIDE AIR DISCHARGE

AIRCOOLED TOP AIR DISCHARGE

WATERCOOLED

KPDHF-200F DN3.0 KPDHF-250F DN3.0

KPDHF-280V DN3.0

KPDHFW-280 DN3.0

KPDHF-280F DN3.0

KPDHF-400V DN2.4

KPDHF-400F DN2.4 KPDHF-450F DN2.4

KPDHF-450V DN2.4

KPDHFW-250 DN3.0

KPDHF-560V DN2.4

KPDHFW-560 DN2.4

SETS

Go back to General Contents Go back to ZEN high capacity Index(Index)

COMMERCIAL RANGE HIGH CAPACITY - AIRCOOLED

124

HIGH CAPACITY DUCTS AIRCOOLED

TECHNICAL SPECIFICATIONS

Working range 200/260: -15ºC to 48ºC (Cooling) / -20ºC to 27ºC (Heating)

K2UF working range: -15ºC to 48ºC (Cooling) / -20ºC to 27ºC (Heating)

OUTDOOR UNIT KMF-200 DN2 KMF-260 DN2 KMF-260 DN2 K2UF-280 DN3Compressor type Double rotary Double rotary Double rotary Scroll Inv.

Outdoor airflow m3/h 10999 10494 10494 11000

Static Pressure Pa No No No 40

Sound pressure dB (A) 59 60 60 57

Refrigerant R-410 A R-410 A R-410 A R-410 A

Refrigerant volume gr 4800 6200 6200 10000

Liquid pipe diameter mm (inch) ø9.52 (3/8") ø12.7 (1/2”) ø19.52 (3/8") ø112.7 (1/2")

Gas pipe diameter mm (inch) ø19.1 (3/4") ø22.2 (7/8") ø122.2 (7/8") ø122.2 (7/8")

Max. piping length m 60 60 60 150

Pipe height difference m 30 30 30 70

Width/Height/Depth mm 1120/1558/528 1120/1558/528 1120/1558/528 960/1615/765

Net weight Kg 137 147 147 245

Power cord (Max. 10 m) mm2 (4+T)x4 (4+T)x4 (4+T)x4 (4+T)x6

Communication wiring mm2 3x1.5 3x1.5 3x1.5 3x1.5

Power supply V / F / Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50

SET KPDHF-200F DN3.0 KPDHF-250F DN3.0 KPDHF-280F DN3.0 KPDHF-280V DN3.0Cooling capacity (min./rated/max.) kW 10.0/20.0/21.1 13.0/25.0/27.5 13.0/26.1/27.5 14.0/28.0/29.6

Cooling capacity (min./rated/max.) Kcal/h 8600/17200/18146 11180/21500/23650 11180/22446/23650 12040/24080/25456

Cooling input W 7610 9015 9110 8710

SEER 6.19 6.42 6.42 6.83

Cooling energy class A++ A++ A++ A++

Heating capacity (min./rated/max.) kW 11.0/22.0/26.1 14.3/27.0/33.7 14.3/28.5/33.7 15.8/31.5/37.3

Heating capacity (min./rated/max.) Kcal/h 9460/18920/22446 12298/23220/28982 12298/24510/28982 13588/27090/32078

Heating input W 7610 8255 8310 9120

SCOP 3.76 4.05 4.05 5.94

Heating efficiency class A A+ A+ A+++

INDOOR UNIT KPDHF-200 DN3.0 KPDHF-250 DN3.0 KPDHF-280 DN3.0 KPDHF-280 DN3.0Indoor airflow m3/h 4800/3900/3500 4600/4000/3600 4600/4000/3600 4600/4000/3600

Static pressure range (rated) Pa 0-200 (120) 0-200 (120) 0-200 (120) 0-200 (120)

Sound pressure (low speed) dB (A) 50 50 50 50

Width/Height/Depth mm 1443/470/810 1443/470/810 1443/470/810 1443/470/810

Net weight Kg 108 108 108 108

Power cord mm2 (2+T)x4 (2+T)x4 (2+T)x4 (2+T)x4

Communication wiring mm2 3x1.5 3x1.5 3x1.5 3x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

Go back to General Contents Go back to ZEN high capacity Index(Index)

Design and Install for you

125

ZE

N

HIG

H C

APA

CITY

CO

MM

ERCI

AL

GENERAL CHARACTERISTICS

CONTROLLERS

BMS AND SOFTWARE

INDIVIDUAL

For further information, please see our Controllers range

CENTRALISED

KCT-02.1 SR KC-02.1 H KCC-16 KCCT-64 IKCC-64 WEB

K01-LON K02-MODBUS K01-BACNET K01-KNX KAYNET CONTROLK01-WIFI

KI-02.3 S

KCT-02.1 SR

TEMPERATURE ADJUSTMENT / GREATER COMFORT +VOLTAGE-FREE DRY CONTACTS+

(*) RECOMMENDED

KAYSUN UK high-pressure ducts have a higher static pressure to cover long distances, which provides greater installation flexibility and accurate air conditioning, even in rooms with high ceilings.

• Refrigerant expansion system into the indoor unit.

• Available static pressure up to 200 Pa.

• Voltage-free ON/OFF dry contact.

• 220V signal output alarm.

• Indoor units 200, 250 and 280 are fitted with DC fan motor.

KCC-64 I-PS

K2UF

KMF

KC-01 S

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you should add to the € price for the set the price

difference between recommended controller and the selected controller.ELIGE TU CONTROL

CHOOSE YOUR CONTROL

PRICE LISTSET MODEL INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE

KPDHF-200F DN3.0 KPDHF-200 DN3.0 KMF-200 DN2 KCT-02.1 SR £4,638

KPDHF-250F DN3.0 KPDHF-250 DN3.0 KMF-260 DN2 KCT-02.1 SR £5,241

KPDHF-280F DN3.0 KPDHF-280 DN3.0 KMF-260 DN2 KCT-02.1 SR £5,271

KPDHF-280V DN3.0 KPDHF-280 DN3.0 K2UF-280 DN3 KCT-02.1 SR £6,050

(*) Price calculation based on the recommended controller.

Go back to General Contents Go back to ZEN high capacity Index(Index)

COMMERCIAL RANGE HIGH CAPACITY - AIRCOOLED

126

HIGH CAPACITY DUCTS AIRCOOLED

TECHNICAL SPECIFICATIONS

OUTDOOR UNIT KMF-400 DN3

KMF-450 DN3

K2UF-400 DN3

K2UF-450 DN3

K2UF-560 DN3

Compressor type Double rotary (2) Double rotary (2) Scroll Inverter + Fixed Scroll (2)

Scroll Inverter + Fixed Scroll (2)

Scroll Inverter + Fixed Scroll (2)

Outdoor airflow m3/h 16575 16575 15000 15000 18000

Static Pressure Pa No No 40 40 40

Sound pressure dB (A) 62 62 60 60 62

Refrigerant type R-410 A R-410 A R-410 A R-410 A R-410 A

Refrigerant factory charge gr 9000 12000 15000 15000 17000

Liquid pipe diameter mm (inch) ø12.7 (1/2”) ø12.7 (1/2”) ø12.7 (1/2”) ø12.7 (1/2”) ø15.9 (5/8")

Gas pipe diameter mm (inch) ø28.6 (1 1/8") ø28.6 (1 1/8") ø28.6 (1 1/8") ø28.6 (1 1/8") ø28.6 (1 1/8")

Max. piping length m 120 120 175 175 200

Pipe height difference m 30 30 70 70 110

Width/Height/Depth mm 1360/1650/540 1460/1650/540 1250/1615/765 1250/1615/765 1390/1615/765

Net weight Kg 240 275 325 325 360

Power cord (10 m max.) mm2 (4+T)x16 (4+T)x16 (4+T)x10 (4+T)x10 (4+T)x16

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5

Power supply V / F / Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50

SET KPDHF-400F DN2.4

KPDHF-450F DN2.4

KPDHF-400V DN2.4

KPDHF-450V DN2.4

KPDHF-560V DN2.4

Cooling capacity (min./rated/max.) kW 20.0/40.0/42.3 22.5/45.0/47.6 20.0/40.0/42.3 22.5/45.0/47.6 28.0/56.0/59.2

Cooling capacity (min./rated/max.) Kcal/h 17200/34400/

3637819350/38700/

40936 17200/34400/

36378 19350/38700/

40936 24080/48160/

50912

Cooling input W 14300 16300 15000 16710 20400

SEER 6.26 6.2 6.18 6.05 6.22

Cooling energy class A++ A++ A++ A++ A++

Heating capacity (min./rated/max.) kW 22.5/45.0/53.3 25.0/50.0/59.2 22.5/45.0/53.3 25.0/50.0/59.2 31.5/63.0/74.6

Heating capacity (min./rated/max.) Kcal/h 19350/38700/

45838 21500/43000/

5091219350/38700/

4583821500/43000/

5091227090/54180/

64156

Heating input W 13800 15400 13890 15480 19400

SCOP 5.33 5.2 5.52 5.29 5.32

Heating efficiency class A+++ A+++ A+++ A+++ A+++

INDOOR UNIT KPDHF-400 DN2.4

KPDHF-450 DN2.4

KPDHF-400 DN2.4

KPDHF-450 DN2.4

KPDHF-560 DN2.4

Indoor airflow m3/h 7700/6400/5200 7700/6400/5200 7700/6400/5200 7700/6400/5200 10100/8400/7000

Static pressure range (rated) Pa 0-200(125) 0-200(125) 0-200(125) 0-200(125) 0-200(125)

Sound pressure (low speed) dB (A) 56 56 56 56 57

Width/Height/Depth mm 1970/668/903 1970/668/903 1970/668/903 1970/668/903 1970/668/903

Net weight Kg 232 232 232 232 235

Power cord mm2 (2+T)x4 (2+T)x4 (2+T)x4 (2+T)x4 (2+T)x4

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

K2UF working range: -15ºC to 48ºC (Cooling) / -20ºC to 27ºC (Heating)

KMF-400/450 working rate: -15ºC to 48ºC (Cooling) / -15ºC to 24ºC (Heating)

Go back to General Contents Go back to ZEN high capacity Index(Index)

Design and Install for you

127

ZE

N

HIG

H C

APA

CITY

CO

MM

ERCI

AL

GENERAL CHARACTERISTICS

KAYSUN UK high-pressure ducts have a higher static pressure to cover long distances, which provides greater installation flexibility and accurate air conditioning, even in rooms with high ceilings.

• Refrigerant expansion system into the indoor unit.

• Available pressure up to 200 Pa.

• Filter is not included in 400, 450 and 560 units.

• Voltage-free ON/OFF dry contact.

• 220V signal output alarm.

CONTROLLERS

INDIVIDUAL

For further information, please see our Controllers range

CENTRALISED

KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB

BMS AND SOFTWARE

K01-LON K02-MODBUS K01-BACNET K01-KNXKAYNET CONTROL K01-WIFI

KCT-02.1 SR KC-02.1 HKI-02.3 S

KCT-02.1 SR

TEMPERATURE ADJUSTMENT / GREATER COMFORT +VOLTAGE-FREE DRY CONTACTS+

(*) RECOMMENDED

K2UF

KMF

KC-01 S

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you should add to the € price for the set the price

difference between recommended controller and the selected controller.ELIGE TU CONTROL

CHOOSE YOUR CONTROL

PRICE LISTSET MODEL INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE

KPDHF-400F DN2.4 KPDHF-400 DN2.4 KMF-400 DN3 KCT-02.1 SR £8,193

KPDHF-450F DN2.4 KPDHF-450 DN2.4 KMF-450 DN3 KCT-02.1 SR £8,947

KPDHF-400V DN2.4 KPDHF-400 DN2.4 K2UF-400 DN3 KCT-02.1 SR £9,112

KPDHF-450V DN2.4 KPDHF-450 DN2.4 K2UF-450 DN3 KCT-02.1 SR £9,578

KPDHF-560V DN2.4 KPDHF-560 DN2.4 K2UF-560 DN3 KCT-02.1 SR £11,405

(*) Price calculation based on the recommended controller.

Go back to General Contents Go back to ZEN high capacity Index(Index)

COMMERCIAL RANGE

128

HIGH CAPACITY - WATERCOOLED

HIGH CAPACITY DUCTS WATERCOOLED

TECHNICAL SPECIFICATIONS

OUTDOOR UNIT K2F-252 DN3W K2F-280 DN3W K2F-560 DN3WNo. of outdoor modules 1 1 2**

Models K2F-252 DN3W K2F-280 DN3W K2F-280 DN3W K2F-280 DN3W

Compressor type Scroll Inverter Scroll Inverter Scroll Inverter Scroll Inverter

Sound pressure dB (A) 51 52 52 52

Refrigerant type R-410 A R-410 A R-410 A R-410 A

Refrigerant factory charge gr 2000 2000 2000 2000

Liquid pipe diameter mm (inch") ø9.52 (3/8") ø12.7 (1/2”) ø15.9 (5/8")

Gas pipe diameter mm (inch") ø19.1 (3/4") ø22.2 (7/8") ø28.6 (1 1/8")

Max. piping length m 150 150 150

Pipe height difference m 50 50 50

Width/Height/Depth mm 780/1000/550 780/1000/550 780/1000/550 780/1000/550

Net weight Kg 146 146 146 146

Power cord (10 m max.) mm2 (4+T)x4 (4+T)x6 (4+T)x6 (4+T)x6

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5

Power supply V / F / Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50

SET KPDHFW-250 DN3.0 KPDHFW-280 DN3.0 KPDHFW-560 DN2.4Cooling capacity (min./rated/max.) kW 12.6/25.2/26.6 14.1/28.0/29.6 14.1/56.0/59.2

Cooling capacity (min./rated/max.) Kcal/h 10836/21672/22876 12126/24080/25456 12126/48160/50912

Cooling input W 6310 7610 15600

Heating capacity (min./rated/max.) kW 14.5/27.0/28.2 17.0/31.5/32.9 17.0/63.0/65.8

Heating capacity (min./rated/max.) Kcal/h 12470/23220/24252 14620/27090/28294 14620/54180/56588

Heating input W 5960 7340 15060

INDOOR UNIT KPDHF-250 DN3.0 KPDHF-280 DN3.0 KPDHF-560 DN2.4Indoor airflow m3/h 4600/4000/3600 4600/4000/3600 10100/8400/7000

Static pressure range (rated) Pa 0-200 (120) 0-200 (120) 0-200(125)

Sound pressure* dB (A) 50 50 57

Width/Height/Depth mm 1443/470/810 1443/470/810 1970/668/903

Net weight Kg 108 108 235

Power cord mm2 (2+T)x4 (2+T)x4 (2+T)x4

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50

*Sound pressure at low speed.

**KCME is required to attach outdoor modules to form the unit

Go back to General Contents Go back to ZEN high capacity Index(Index)

Design and Install for you

129

ZE

N

HIG

H C

APA

CITY

CO

MM

ERCI

AL

KCT-02.1 SR

GENERAL CHARACTERISTICS

KAYSUN UK high-pressure ducts have a higher static pressure to cover long distances, which provides greater installation flexibility and accurate air conditioning, even in rooms with high ceilings.

• Refrigerant expansion system into the indoor unit.

• Available pressure up to 200 Pa.

• 560 units do not include filter.

• Voltage-free ON/OFF dry contact.

• 220V signal output alarm.

• Indoor units 200, 250 and 280 are fitted with Dc fan motor.

TEMPERATURE ADJUSTMENT / GREATER COMFORT +VOLTAGE-FREE DRY CONTACTS+

CONTROLLERS

BMS AND SOFTWARE

INDIVIDUAL

For further information, please see our Controllers range

CENTRALISED

KCT-02.1 SRKC-02.1 H KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEBKI-02.3 S

CONDENSED BY WATER +

K01-LON K02-MODBUS K01-BACNET K01-KNXKAYNET CONTROL K01-WIFI

(*) RECOMMENDED

KC-01 S

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you should add to the € price for the set the price

difference between recommended controller and the selected controller.ELIGE TU CONTROL

CHOOSE YOUR CONTROL

PRICE LISTSET MODEL INDOOR UNIT OUTDOOR UNIT RECOMMENDED CONTROL PRICE

KPDHFW-250 DN3.0 KPDHF-250 DN3.0 K2F-252 DN3W KCT-02.1 SR £6,906

KPDHFW-280 DN3.0 KPDHF-280 DN3.0 K2F-280 DN3W KCT-02.1 SR £7,564

KPDHFW-560 DN2.4 KPDHF-560 DN2.4 K2F-560 DN3W KCT-02.1 SR £14,942

(*) Price calculation based on the recommended controller.

Go back to General Contents Go back to ZEN high capacity Index(Index)

COMMERCIAL RANGE

130

HIGH CAPACITY STATIC PRESSURE GRAPHS

HIGH CAPACITY DUCTS STATIC PRESSURE GRAPHS

KPDHF-200 DN3.0

KPDHF-250 (280) DN3.0

Go back to General Contents Go back to ZEN high capacity Index(Index)

Design and Install for you

131

ZE

N

HIG

H C

APA

CITY

CO

MM

ERCI

AL

KPDHF-400(450) DN 2.4

KPDHF-560 DN 2.4

56KW/h (50Hz)

Go back to General Contents Go back to ZEN high capacity Index(Index)

AMAZON INDUSTRIAL VRF RANGE

Design and Install for you

133

INTRODUCTION TO THE PRODUCT RANGE .............................................. .134

INDOOR UNITS ..........................................................................................141

WALL ................................................... ..............KAYF.......................143

DOUBLE FLOW CONSOLE .................. ..............KSDF........................145

FLOOR STANDING EXPOSED/CONCEALED......KS(E)F.......................147

CEILING/FLOOR .................................. ...............KPCF.............. ..........149

ONE WAY CASSETTE ......................... ...............KCOF.............. ..........151

ART FLUX 360º (600x600) CASSETTE.............KCIF.............. ...........153

ART FLUX 360º CASSETTE........ ........ ...............KCIF.............. ...........155

DUCTS.................................................. ...............KPDF.............. ......... 157

STATIC PRESSURE GRAPHS ....... ............ ................................... 161

HIGH PRESSURE DUCTS ................... ...............KPDHF ..................... 165

KAHU ................................................... ...............KAHU.............. ........ 169

DOMESTIC HOT WATER RECOVERY KIT............KWF.............. .......... 171

OUTDOOR UNITS ........................................................................................174

2 PIPES ..................................................................................................... 176

MINI AMAZON VRF

SINGLE-PHASE....... ............... ...............KMF DVN2 .............. 178

THREE-PHASE ................................... ...KMF DTN2 .............. 180

AMAZON UNITARIO SIDE AIR DISCHARGE.......KMF ....................... 182

AMAZON UNITARIO TOP AIR DISCHARGE.......K2UF ....................... 184

AMAZON IV PRO ................................ ...............K2F DN4S ............... 186

AMAZON III W .................................... ...............K2F DN3W .............. 188

3 PIPES ...................................................................................................... 190

AMAZON III PRO ................................. ...............K3F DN3S ............... 192

KVB BOXES..................... ....... ...............KVB .........................194

SIZING OF PIPES ....................................................................................... 196

DISTANCES AND HEIGHT DIFFERENCES ...............................................202

AMAZONINDUSTRIAL VRF RANGE

INDUSTRIAL VRF RANGE

134

INTRODUCTION TO THE RANGE OF PRODUCTS

INDUSTRIAL VRF RANGEAMAZONWithin the world of air-conditioning, the variable refrigerant flow systems (VRF) are the most versatile in terms of installation possibilities and technological innovation. Thanks to the DC Inverter technology, which varies the frequency of the compressor motor and fan motor of the outdoor unit depending on the total required load, and thanks to electronic expansion valves (both in the outdoor and the indoor units), which regulate the flow of refrigerant depending on the load required for each area, higher levels of efficiency and superior energy savings are achieved. The installation distances available are among the longest in the market, reaching up to 200 meters of equivalent length between the outdoor unit and the farthest indoor unit.

The possibilities of the indoor units are endless, not only for the different models available, but also for their capacity range, which is so wide that it covers from 1.5 kW to 56 kW

and allows for installing up to 64 indoor units in the same cooling circuit. The independent control of indoor units allows each user to choose its own comfort level without interfering with the rest of users.

Our wide range of controllers provides end-user with many options to define its level of comfort. They allow installing from a simple individual control (wireless or wired), a centralised control, a computer control and even the possibility of managing the installation from a comprehensive building management system BMS (LONWORKS, MODBUS, BACNET and KNX).

“THE BROADEST PRODUCT RANGE ON THE MARKET”

AMAZON UNITARIO SIDE AIR DISCHARGE (2 PIPES)

• DC Inverter fan motors Side air discharge

• DC Inverter compressors

• 40 AND 45 kW• Up to 15 indoor units• Up to 150% simultaneity • Auto-addressing• XYE port to connect a centralised control of indoor units

FOR PIPELINES250 m

COMPACT DESIGN

INSTALLATION SPACE

+

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

135

AM

AZ

ON

IND

US

TRIA

L V

RF

SLIM DESIGN SOFT AIRFLOW

LOW SOUND LEVELS

INTERACTIVE DISPLAY

RENEWED PANEL

AIR INLET DUCT FRAME AND AIR OUTLET DUCT FRAME INCLUDED

REAR/LOWER AIR INLET

STATIC PRESSURE CHANGE (OPTIONAL)

INDOOR UNITS WITH DC INVERTER FAN

Most KAYSUN UK AMAZON indoor units include a DC Inverter motor fan. This development provides units with a much more accurate control, and greater output and energy savings, and it reduces sound (low) pressure.

Our units are better suited to the installation requirements of the areas in need of air conditioning, thereby making users' comfort, well-being and energy savings a top priority.

WALL-MOUNTED

CASSETTE ART FLUX 360º

DUCTS

CEILING/FLOOR

HIGH PRESSURE DUCTSCASSETTE ART FLUX 360º (600x600)

CONDENSATION PUMP

COMPACT UNIT

360° AIRFLOW

360° AIRFLOW DOUBLE INSTALLATION

WIDE POWER RANGE

HIGH AIRFLOW

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE

136

INTRODUCTION TO THE RANGE OF PRODUCTS

COMPENSATION TECHNOLOGY FOR HIGH-PERFORMANCE OIL

The design of the Scroll DC Inverter compressor is based on the highest technology available.

With a more compact structure, this compressor provides maximum performances, increases efficiency and reduces power consumption when the system is working at partial loads.

The compressor, which has been optimized for using R410A ecological refrigerant, has received the highest energy classification for both cooling and heating operation - EER and COP.

Speed in DC can be adjusted and results in energy savings of up to 25%, more than any other conventional equipment on the market.

NEW STRUCTURE AND HIGH ENERGY EFFICIENCY AT PARTIAL LOAD

NEW SERRATED DESIGN FOR R410A

50% LIGHTER, THANKS TO ITS DESIGN

THE ELABORATE DESIGN OF THE COMPRESSOR ALLOWS A MORE CENTRALISED MAGNETIC FLOW

IT USES A DC INVERTER MOTOR

CENTRALISED WINDING

The DC Inverter compressor's technology used in KAYSUN's AMAZON units, are fitted with centralised winding instead of distributing winding. This type of winding consists of very powerful magnets that allow for increasing the force of rotation and therefore, the compressor's effectiveness.

EFFECTIVENESS OF THE COMPRESSOR

20 40 60 80 100 ROTOR SPEED(S-1)

Central coil

New DC motor

Dispensing coil

70% Reduction

Common DC motor

EFFECTIVENESS OF THE COMPRESSOR

20 40 60 80 100 ROTOR SPEED(S-1)

Central coil

New DC motor

Dispensing coil

70% Reduction

Common DC motor

HIGH INVERTER TECHNOLOGY

Outdoor units ensure individualised control and homogeneous distribution of oil between modules so that the compressor is able to provide a smooth and reliable performance. The oil balance and outlet pipes send the compressor's remaining oil to a system that will distribute it uniformly to the other compressors.

The oil separator, is capable to work with an efficiency over 99%, by sending oil to the compressors on time and effectively in order to ensure that they have the correct amount of oil. This system is designed to extend the working life of KAYSUN UK units' compressors as much as possible.

DIS

CHA

RG

E PI

PE

HIGH PRESSURE GAS

SUCTION PIPE

high-performanceoil separator 99%

condenser inlet

oil balancing door between modules

OIL

BA

LAN

CIN

G P

IPE

BET

WEE

N

MO

DU

LES

III

from indoor units

OIL CLEARING PIPE II

OILCLEARING

PIPE I

compressor

INLET PIPE

DISCHARGE PIPE

OIL COMPENSATION PIPE

OIL PAN

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

137

AM

AZ

ON

IND

US

TRIA

L V

RF

600

500

400

300

200

100

STARTING FREQUENCY (%)

TIME (SEG)1 2 3 4 5 6

ON/OFF switch Switch Inverter switch

SMART SOFT-STARTER TECHNOLOGY

DC INVERTER compressors characterise by a soft, low frequency and low power consumption starter. This reduces the risk of overloading the power grid and prevents excessive consumption peaks during outdoor unit starting.(*) Comparison between starting with an inverter starter and with a conventional starter.

FLUCTUATION TEMPERATURE (ºC)

TIME (H)

Inverter

ON/OFF

1 2

Our units are extremely quiet and efficient thanks to their DC Inverter fan, which allows for reducing noise level from 2-5 dB (A) and increases the airflow from 1000 to 4000m3/h.

FAN

1000

200

ROTOR SPEED (PPM)

SYSTEM PRESSURE (Pa)

18 LEVELSof speed adjustment

100

80

60

40

20

EFFECTIVENESS (%)

MOTOR SPEED (RPM)

200 1000

Increase 45%

40 Pa

PROPELLER FAN

The new helical shape of the fan's blades supplies a large volume of air whilst reducing vibrations and resistance to a minimum.

DC INVERTER MOTOR

The fan’s DC Inverter motor consumes minimal energy since the fan speed can be regulated depending on the power demand and the operating pressure of the cooling circuit.

OPTIMISED AIRFLOW OUTLET

The efficiency of the fan’s airflow has been improved thanks to the fan’s new design. This, in combination with the DC Inverter motor, allows for a static pressure increase of up to 40 Pa, a pressure loss decrease and a 10% optimization of the airflow.

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE

138

INTRODUCTION TO THE RANGE OF PRODUCTS

WORKING RANGE

Thanks to the new DC Inverter technology, the AMAZON range offers increased operability for cooling and heating modes within a much larger working range, thereby ensuring a perfect air-conditioning control during all seasons of the year.

HEAT EXCHANGER OPTIMIZATION

The heat exchanger of the 12, 20 and 22 HP models of AMAZON IV has been optimised to reduce their volume by adding an extra row to its large surface. Besides, the delta-shaped heat exchanger helps to improve subcooling.

OPERATING MODE LOCKING FUNCTION (2 PIPES)

From a switch located at the outdoor unit's electronic board, user may select 6 different operating modes for the cooling system:

1. Heating mode priority (default).2. Cooling mode priority.3. Cooling mode only.4. Heating mode only.5. Unit addressed as no. 63 determines the operating mode.6. Those units with the same operating mode forming a majority shall determine the operation mode of the whole system.

ROTARY AND CONSTANTLY VENTILATED ELECTRICAL BOX

The electrical box of the AMAZON IV units, apart from providing boards' electronic parts with constant ventilation by means of a heat dissipation system, is completely rotary in order to facilitate the access inside the unit.

The outdoor units' design allows for an easy installation and maintenance. The new electrical box includes an inspection window in the main electronic board that allows for a straightforward access from outside the equipment. The compressor is located just opposite the electric box to make access easier when its replacement is required.

EASY INSTALLATION AND MAINTENANCE

* For further information on AMAZON IV for other rang-es, please check temperature tables.

CENTRALISED CONTROLLER WIRING

All AMAZON systems have an XYE port in the outdoor unit, allowing the three wires of the centralised control cable between the indoor units to be dispensed with. This means that it is possible to connect directly to the XYE port.

XYE PORT DE CONNEXION

AUTO-ADDRESS OF THE INDOOR UNITS

There are two address setting options for indoor units:

Automatic: Using the SW6 switch of the outdoor unit (deactivated by default), the outdoor unit automatically distributes the address to the indoor units with no manual adjustment.

Manual: The address of all indoor units can be consulted and modified using the KI-02.3 S wireless controller or the KCT-02.1 SR wired controller.

MODULES AUTOMATIC REDUNDANCY

AMAZON's intelligent control system, defines the boot priority of the module according to the system load, and balances its operating time to optimise reliability and working life of the unit.

Mural no. 1 Mural no. 2

Mural no. 3 Mural no. 4

OUTDOOR UNIT

INDOOR UNITS

SW6 KI-02.3 S controller

48 ºC

-5 ºC -20 ºC

21 ºC

outdoortemp.

outdoortemp.

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

139

AM

AZ

ON

IND

US

TRIA

L V

RF

WORKING RANGE

The AMAZON units have one of the highest energy efficiency ratings in the market, with very high EER and COP scores. Furthermore, since outdoor units are modular, units with the best EER/COP scores can be combined to provide higher energy efficiency in facilities that require large cooling capacity.

4.35

5.09

4.08

4.57 4.21

4.12

4.07

4.03

3.85

3.75

4.15

4.033.74 3.76

3.43

3.25

3.30

3.203.62 3.39

252 280 335 400 450

Amazon IV

Conventional VRF system

EER

CO

P

Amazon IV

Conventional VRF system

POWER

4.00

3.70

4.00

3.94

3.80

3.70

3.40 3.40

3.303.103.003.25

500 560 615

ECODESIGN

KAYSUN UK not only offers the most technologically advanced products of the market, but also makes every single effort to produce them under the strictest ecological standards in order to ensure a minimal negative impact on the environment.

A NOD TO ENVIRONMENT

R-410A REFRIGERANT

The Amazon system uses the environmentally friendly refrigerant R410A, which, in addition to having high efficiency and energy savings it is characterised for being respectful of the ozone layer and helps us to reduce the impact on the environment.

8 / 10 / 12 14 / 16 / 18 / 20 / 22

Energy saving

Ecodesign

92% Recyclable

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

140

INDOOR UNITS

FEATURES

INDUSTRIAL VRF RANGE

141

POWER RANGE

POWER kW

POWER kW

WALL-MOUNTED

DOUBLE FLOW CONSOLE

FLOOR STANDING EXPOSED/CONCEALED

CASSETTE ART FLUX 360º (600x600)

CASSETTE ART FLUX 360º

DOMESTIC HOT WATER RECOVERY KIT

DUCTS

HIGH PRESSURE DUCTS

CEILING/FLOOR

ONE WAY CASSETTE

KAHU

1.5 2.2 2.8 3.6 4.5 5.6

7.1 9.0 11.2 14.0 16.0

KPDHF-71 DN3.0 KPDHF-90 DN3.0 KPDHF-112 DN3.0

KSDF-45 DN2.3KSDF-28 DN2.3 KSDF-36 DN2.3

KPDHF-140 DN3.0

KAHU-200.2

KCIF-15 DN3.0 KCIF-28(22) DN3.0 KCIF-36 DN3.0 KCIF-45 DN3.0

KPDHF-160 DN3.0

KAYF-22 DN3.0 KAYF-28 DN3.0 KAYF-36 DN3.0 KAYF-45 DN3.0 KAYF-56 DN3.0

KPDF-15 DN3.0 KPDF-22 DN3.0 KPDF-28 DN3.0 KPDF-36 DN3.0 KPDF-45 DN3.0 KPDF-56 DN3.0

KCIFB-56 DN3.0

KPCF-56 DN3.0

KS(E)F-56 DN2.3

KSEF-56 DN2.3

INDOOR UNITS

NEW

NEW

KCOF-22 DN2.4 KCOF-36 DN2.4

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

142

AM

AZ

ON

IND

US

TRIA

L V

RF

7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 18.0

20.0 25.0 28.0 36.0 40.0 45.0 50.0 56.0 60.0

KPDHF-200 DN3.0 KPDHF-250 DN3.0

KAYF-80 DN3.0

KPDHF-280 DN3.0

KAHU-360.2

KPDHF-400 DN2.4 KPDHF-450 DN2.4 KPDHF-560 DN2.4

KAHU-560.2

KPDF-71 DN3.0 KPDF-90 DN3.0KPDF-80 DN3.0 KPDF-112 DN3.0 KPDF-140 DN3.0

KCIFB-71 DN3.0 KCIFB-80 DN3.0 KCIFB-100 DN3.0 KCIB-112 DN3.0 KCIF-140 DN3.0

KWF-140 ACS

KPCF-90 DN3.0 KPCF-140 DN3.0

KS(E)F-80 DN2.3

KCOF-71 DN2.4

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE INDOOR UNITS

143

33

MODEL KAYF-22 DN3.0

KAYF-28 DN3.0

KAYF-36 DN3.0

KAYF-45 DN3.0

KAYF-56 DN3.0

KAYF-80 DN3.0

Cooling capacity kW 2.2 2.8 3.6 4.5 5.6 8

Cooling capacity Kcal/h 1892 2408 3096 3870 4816 6880

Heating capacity kW 2.4 3.2 4 5 6.3 9

Heating capacity Kcal/h 2064 2752 3440 4300 5418 7740

Power input kW 0.008 0.009 0.019 0.019 0.027 0.053

Indoor airflow m3/h 422/393/356 417/370/316 656/573/488 594/507/424 747/648/547 1195/1005/809

Sound pressure* dB (A) 29 29 30 31 34 36

Width/Height/Depth mm 835/280/203 835/280/203 990/315/223 990/315/223 990/315/223 1194/343/262

Net weight Kg 8.4 9.5 11.4 12.8 12.8 17

Liquid pipe diameter mm (inch") ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8") ø9.52 (3/8")

Gas pipe diameter mm (inch") ø12.7 (1/2") ø12.7 (1/2") ø12.7 (1/2") ø12.7 (1/2") ø15.9 (5/8") ø15.9 (5/8")

Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

The main features of our wall-mounted units are a DC INVERTER fan and the smart design of their panel. They include a LED display located at the centre of the unit that provides it with a modern design by using the most advanced technology in the market.

• Low noise level, creating a peaceful and comfortable atmosphere.

• The swing angle of the louvres may reach up to 90º.

• Built-in expansion valve.

• ON/OFF dry contact and 220 V alarm signal output.

• DC INVERTER fan included.

• Left inlet for installation pipes (front view).

TECHNICAL SPECIFICATIONS

WALL-MOUNTED

All AMAZON indoor units accept R-410 A refrigerant.*Sound pressure at low fan speed.

GENERAL CHARACTERISTICS

COMPATIBLE WITH

MINI AMAZON2 PIPES

see pag. 182

AMAZON UNITARIO2 PIPES

see pag. 186

AMAZON III PRO3 PIPES

see pag. 196

AMAZON III W2 PIPES

see pag. 192

AMAZON IV PRO2 PIPES

see pag. 190

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

144

AM

AZ

ON

IND

US

TRIA

L V

RF

KI-02.3 S

(*) RECOMMENDED

CONTROLLERS

KC-02.1 H

For further information, please see our Controllers range

KI-02.3 SKCT-02.1 SR

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you should add to the € price for the set the price

difference between the recommended controller and the selected controller.

LOW SOUND LEVEL +

DC INVERTER FAN+

BMS AND SOFTWARE

CENTRALISEDINDIVIDUAL

KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB

K01-LON K02-MODBUS K01-BACNET KAYNET CONTROL K01-KNX K01-WIFI

KC-01 S

ELIGE TU CONTROL

CHOOSE YOUR CONTROL

PRICE LISTMODEL RECOMMENDED CONTROL PRICE

KAYF-22 DN3.0 KI-02.3 S £413

KAYF-28 DN3.0 KI-02.3 S £437

KAYF-36 DN3.0 KI-02.3 S £447

KAYF-45 DN3.0 KI-02.3 S £526

KAYF-56 DN3.0 KI-02.3 S £559

KAYF-80 DN3.0 KI-02.3 S £681

(*) Price calculation based on the recommended controller.

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE INDOOR UNITS

145

33

With a modern and cutting-edge design, the consoles can be gracefully incorporated into any space. Their reduced depth, provides the unit with an external flexible design that adapts to every installation, from floor standing installations to low wall-mounted installations, without affecting their capacity.

• They reach the selected temperature more quickly by means of four return air inlets and two supply outlets.

• DC Inverter FAN MOTOR.

• Low starting power and precise room temperature adjustment.

• The electronic expansion valve is integrated inside the indoor unit.

DOUBLE FLOW CONSOLE

TECHNICAL SPECIFICATIONS

GENERAL CHARACTERISTICS

MODEL KSDF-28 DN2.3 KSDF-36 DN2.3 KSDF-45 DN2.3

Cooling capacity kW 2.8 3.6 4.5

Cooling capacity Kcal/h 2408 3096 3870

Heating capacity kW 3.2 4 5

Heating capacity Kcal/h 2752 3440 4300

Power input kW 0.025 0.025 0.045

Indoor airflow m3/h 510/430/229 510/430/229 660/512/400

Sound pressure* dB (A) 27 27 36

Width/Height/Depth mm 700/600/210 700/600/210 700/600/210

Net weight Kg 15 15 15

Liquid pipe diameter mm (inch") Ø6.35 (1/4") Ø6.35 (1/4") Ø6.35 (1/4")

Gas pipe diameter mm (inch") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2")

Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50

All AMAZON indoor units accept R-410 A refrigerant.*Sound pressure at low fan speed.

COMPATIBLE WITH

MINI AMAZON2 PIPES

see pag. 182

AMAZON UNITARIO2 PIPES

see pag. 186

AMAZON III PRO3 PIPES

see pag. 196

AMAZON III W2 PIPES

see pag. 192

AMAZON IV PRO2 PIPES

see pag. 190

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

146

AM

AZ

ON

IND

US

TRIA

L V

RF

ACCURATE ROOM TEMP. ADJUSTMENT+

DC INVERTER FAN +

CONTROLLERS

KC-02.1 H

For further information, please see our Controllers range

KCT-02.1 SR

BMS AND SOFTWARE

CENTRALISEDINDIVIDUAL

KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB

K01-LON K01-BACNET KAYNET CONTROL K01-KNX K01-WIFIK02-MODBUS

KI-02.3 S

(*) RECOMMENDED

KI-02.3 SKC-01 S

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you should add to the € price for the set the price

difference between the recommended controller and the selected controller.ELIGE TU CONTROL

CHOOSE YOUR CONTROL

(*) Price calculation based on the recommended controller.

PRICE LISTMODEL RECOMMENDED CONTROL PRICE

KSDF-28 DN2.3 KI-02.3 S £569

KSDF-36 DN2.3 KI-02.3 S £610

KSDF-45 DN2.3 KI-02.3 S £644

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE INDOOR UNITS

147

The streamlined design of this unit, due mainly to its reduced depth, is the perfect solution for saving space and adapting to every installation, from wall-mounted to floor standing, whether totally or partially recessed, thereby gracefully harmonising with the interior design of the room.

• Built-in expansion valve.

• ON/OFF dry contact and 220 V alarm signal output.

• Its 12Pa static pressure helps move air supply.

FLOOR STANDING EXPOSED/CONCEALED

GENERAL CHARACTERISTICS

TECHNICAL SPECIFICATIONS

MODEL KSEF-56 DN2.3 KS(E)F-56 DN2.3 KS(E)F-80 DN2.3

Cooling capacity kW 5.6 5.6 8

Cooling capacity Kcal/h 4816 4816 6880

Heating capacity kW 6.3 6.3 9

Heating capacity Kcal/h 5418 5418 7740

Power input kW 0.088 0.088 0.13

Indoor airflow m3/h 1150/970/830 1150/970/830 1380/1100/870

Sound pressure* dB (A) 31 31 33

Width/Height/Depth CONCEALED mm - 1500/596/225 1500/596/225

Width/Height/Depth EXPOSED mm 1500/544/212 1500/544/212 1500/544/212

Net weight CONCEALED Kg - 42 44

Net weight EXPOSED Kg 41 41 42.5

Liquid pipe diameter mm (inch") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8")

Gas pipe diameter mm (inch") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8")

Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50

All AMAZON indoor units accept R-410 A refrigerant.*Sound pressure at low fan speed.

COMPATIBLE WITH

MINI AMAZON2 PIPES

see pag. 182

AMAZON UNITARIO2 PIPES

see pag. 186

AMAZON III PRO3 PIPES

see pag. 196

AMAZON III W2 PIPES

see pag. 192

AMAZON IV PRO2 PIPES

see pag. 190

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

148

AM

AZ

ON

IND

US

TRIA

L V

RF

CONCEALED EXPOSED

PA STATIC PRESSURE 12

CONTROLLERS

KC-02.1 H

For further information, please see our Controllers range

KCT-02.1 SR

BMS AND SOFTWARE

CENTRALISEDINDIVIDUAL

KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB

K01-LON K01-BACNET KAYNET CONTROL K01-KNX K01-WIFIK02-MODBUS

KI-02.3 S

(*) RECOMMENDED

KI-02.3 SKC-01 S

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you should add to the € price for the set the price

difference between the recommended controller and the selected controller.ELIGE TU CONTROL

CHOOSE YOUR CONTROL

PRICE LISTMODEL RECOMMENDED CONTROL PRICE

KSEF-56 DN2.3 KI-02.3 S £644

KS(E)F-56 DN2.3 KI-02.3 S £644

KS(E)F-80 DN2.3 KI-02.3 S £705

(*) Price calculation based on the recommended controller.

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE INDOOR UNITS

149

CEILING / FLOOR

GENERAL CHARACTERISTICS

Ceiling/Floor VRF indoor unit with DC INVERTER motors. Its compact design helps integrating the unit into every environment. As its name suggests, these units can be installed on the ceiling in horizontal position and on the floor in vertical position. The design of their condensation water tray so permits.

• Built-in expansion valve.

• ON/OFF dry contact and 220 V alarm signal output.

• Smoother airflow with less turbulences. Thanks to the multi blades fan and the design of its louvres, the airflow is softer and more comfortable.

• Indoor units with DC INVERTER fan.

TECHNICAL SPECIFICATIONS

MODEL KPCF-56 DN3.0 KPCF-90 DN3.0 KPCF-140 DN3.0

Cooling capacity kW 5.6 9 14

Cooling capacity Kcal/h 4816 7740 12040

Heating capacity kW 6.3 10 15.5

Heating capacity Kcal/h 5418 8600 13330

Power input kW 0.094 0.126 0.13

Indoor airflow m3/h 930/830/720 1280/1170/1050 1980/1860/1730

Sound pressure* dB (A) 38 40 42

Width/height/depth (floor installation) mm 990/660/203 1280/660/203 1670/680/244

Net weight Kg 27 33.5 49

Liquid pipe diameter mm (inch") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8")

Gas pipe diameter mm (inch") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8")

Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50

All AMAZON indoor units accept R-410 A refrigerant.*Sound pressure at low fan speed.

COMPATIBLE WITH

MINI AMAZON2 PIPES

see pag. 182

AMAZON UNITARIO2 PIPES

see pag. 186

AMAZON III PRO3 PIPES

see pag. 196

AMAZON III W2 PIPES

see pag. 192

AMAZON IV PRO2 PIPES

see pag. 190

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

150

AM

AZ

ON

IND

US

TRIA

L V

RF

DC INVERTER FAN+

CONTROLLERS

KC-02.1 H

For further information, please see our Controllers range

KCT-02.1 SR

BMS AND SOFTWARE

CENTRALISEDINDIVIDUAL

KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB

K01-LON K01-BACNET KAYNET CONTROL K01-KNX K01-WIFIK02-MODBUS

KI-02.3 S

(*) RECOMMENDED

KI-02.3 SKC-01 S

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you should add to the € price for the set the price

difference between the recommended controller and the selected controller.ELIGE TU CONTROL

CHOOSE YOUR CONTROL

PRICE LISTMODEL RECOMMENDED CONTROL PRICE

KPCF-56 DN3.0 KI-02.3 S £619

KPCF-90 DN3.0 KI-02.3 S £770

KPCF-140 DN3.0 KI-02.3 S £838

(*) Price calculation based on the recommended controller.

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE INDOOR UNITS

151

KAYSUN UK One way cassette. Stands at just 153mm in height, depending on the capacity of the unit. It has a compact and light design, making it very easy to install and maintain in any space. These units are perfectly merged with the ceiling, creating a clean and subtle aesthetic.

• The control box is built into the body of the unit. This saves space and allows facilitates maintenance.

• Standard condensation pump.

• It has a very reduced height, making it ideal for very low suspended ceilings.

ONE WAY CASSETTE

TECHNICAL SPECIFICATIONS

GENERAL CHARACTERISTICS

MODEL KCOF-22 DN2.4 KCOF-36 DN2.4 KCOF-71 DN2.4

Cooling capacity kW 2.2 3.6 7.1

Cooling capacity Kcal/h 1892 3096 6106

Heating capacity kW 2.6 4 8

Heating capacity Kcal/h 2236 3440 6880

Power input kW 0.041 0.041 0.055

Indoor airflow m3/h 523/404/275 573/456/315 933/749/592

Sound pressure* dB (A) 30 34 37

Width/Height/Depth mm 1054/153/425 1054/153/425 1275/189/450

Net weight Kg 12.5 13 18.8

Width/Height/Depth (panel) mm 1180/25/465 1180/25/465 1350/25/505

Net weight (panel) Kg 3.5 3.5 4

Liquid pipe diameter mm (inch") Ø6.35 (1/4") Ø6.35 (1/4") Ø12.7 (1/2")

Gas pipe diameter mm (inch") Ø12.7 (1/2") Ø12.7 (1/2") Ø15.9 (5/8")

Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50

NEW

All AMAZON indoor units accept R-410 A refrigerant.*Sound pressure at low fan speed.

COMPATIBLE WITH

MINI AMAZON2 PIPES

see pag. 182

AMAZON UNITARIO2 PIPES

see pag. 186

AMAZON III PRO3 PIPES

see pag. 196

AMAZON III W2 PIPES

see pag. 192

AMAZON IV PRO2 PIPES

see pag. 190

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

152

AM

AZ

ON

IND

US

TRIA

L V

RF

STANDARD CONDENSATION PUMP+UP TO 153 MM IN HEIGHT+

CONTROLLERS

KC-02.1 H

For further information, please see our Controllers range

KCT-02.1 SR

BMS AND SOFTWARE

CENTRALISEDINDIVIDUAL

KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB

K01-LON K01-BACNET KAYNET CONTROL K01-KNX K01-WIFIK02-MODBUS

KI-02.3 S

(*) RECOMMENDED

KI-02.3 S

NEW

KC-01 S

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you should add to the € price for the set the price

difference between the recommended controller and the selected controller.ELIGE TU CONTROL

CHOOSE YOUR CONTROL

PRICE LISTMODEL RECOMMENDED CONTROL PRICE

KCOF-22 DN2.4 KI-02.3 S £634

KCOF-36 DN2.4 KI-02.3 S £770

KCOF-71 DN2.4 KI-02.3 S £899

(*) Price calculation based on the recommended controller.

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE INDOOR UNITS

153

With its new 360º panel and DC INVERTER fan, the Art Flux Cassette unit provides even, fast and far-reaching air-conditioning control, without leaving dead zones. Since the main unit and panel are compact and lighter, less space and equipment are needed to install it. They can be completely integrated into any space, including shallow ceilings, without sticking out.

• ON/OFF dry contact and 220 V alarm signal output.

• Integrated control box inside the unit's body; it saves space and allows for ceiling installation.

• Ducts pre-installation holes, to supply air to adjoining rooms.

• Electronic expansion valve kit on one side of the unit.

• Indoor units with DC INVERTER FAN.

• Fresh air possibility to enter directly into the room through a pre-installation hole located at the unit’s body.

• Standard condensation pump.

ART FLUX 360º (600x600) CASSETTE

GENERAL CHARACTERISTICS

TECHNICAL SPECIFICATIONS

MODEL KCIF-15 DN3.0 KCIF-28(22)DN3.0** KCIF-36 DN3.0 KCIF-45 DN3.0

Cooling capacity kW 1.5 2.8 (2.2) 3.6 4.5

Cooling capacity Kcal/h 1290 2408 (1892) 3096 3870

Heating capacity kW 1.7 3.2 (2.6) 4 5

Heating capacity Kcal/h 1462 2742 (2236) 3440 4300

Power input kW 0.014 0.015 0.021 0.021

Indoor airflow m3/h 526/449/364 522/449/364 604/516/400 604/516/400

Sound pressure* dB (A) 21 22 27 27

Width/Height/Depth mm 570/260/570 570/260/570 570/260/570 570/260/570

Net weight Kg 16 16 17.5 17.5

Width/Height/Depth (panel) mm 648/50/648 648/50/648 648/50/648 648/50/648

Panel net weight Kg 3 3 3 3

Liquid pipe diameter mm (inch") Ø6.35 (1/4") Ø6.35 (1/4") Ø6.35 (1/4") Ø6.35 (1/4")

Gas pipe diameter mm (inch") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2")

Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

All AMAZON indoor units accept R-410 A refrigerant.*Sound pressure at low fan speed.**KCIF-28 DN3.0 model is compatible with KCIF-22 DN3.0 model.

COMPATIBLE WITH

MINI AMAZON2 PIPES

see pag. 182

AMAZON UNITARIO2 PIPES

see pag. 186

AMAZON III PRO3 PIPES

see pag. 196

AMAZON III W2 PIPES

see pag. 192

AMAZON IV PRO2 PIPES

see pag. 190

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

154

AM

AZ

ON

IND

US

TRIA

L V

RF

360º AIR DIFFUSION +

DC INVERTER FAN+

CONTROLLERS

KC-02.1 H

For further information, please see our Controllers range

KCT-02.1 SR

BMS AND SOFTWARE

CENTRALISEDINDIVIDUAL

KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB

K01-LON K01-BACNET KAYNET CONTROL K01-KNX K01-WIFIK02-MODBUS

KI-02.3 S

(*) RECOMMENDED

KI-02.3 SKC-01 S

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you should add to the € price for the set the price

difference between the recommended controller and the selected controller.ELIGE TU CONTROL

CHOOSE YOUR CONTROL

(*) Price calculation based on the recommended controller.

PRICE LISTMODEL RECOMMENDED CONTROL PRICE

KCIF-15 DN3.0 KI-02.3 S £528

KCIF-28(22) DN3.0 KI-02.3 S £558

KCIF-36 DN3.0 KI-02.3 S £586

KCIF-45 DN3.0 KI-02.3 S £647

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE INDOOR UNITS

155

33

33

With its new 360º panel and DC INVERTER fan, the Art Flux Cassette unit provides even, fast and far-reaching air-conditioning control, without leaving dead zones. The unit is so compact and light that it can be integrated into any space, including shallow ceilings, without sticking out.

• Electronic expansion valve kit on one side of the unit.

• ON/OFF dry contact and 220 V alarm signal output.

• Integrated control box inside the unit's body; it saves space and allows for ceiling installation.

• Ducts pre-installation holes, to supply air to adjoining rooms.

• Fresh air possibility to enter directly into the room through a pre-installation hole located at the unit’s body.

• Indoor units with DC INVERTER FAN.

• Standard condensation pump.

CASSETTE ART FLUX 360º

GENERAL CHARACTERISTICS

MODEL KCIBF-56 DN3.0

KCIBF-71 DN3.0

KCIBF-80 DN2.3

KCIBF-100 DN3.0

KCIBF-112 DN3.0

KCIBF-140 DN3.0

Cooling capacity kW 5.6 7.1 8 10 11.2 14

Cooling capacity Kcal/h 4816 6106 6880 8600 9632 12040

Heating capacity kW 6.3 8 9 11 12.5 15

Heating capacity Kcal/h 5418 6880 7740 9460 10750 12900

Power input kW 0.031 0.046 0.048 0.11 0.11 0.12

Indoor airflow m3/h 1029/857/704 1200/996/748 1264/1055/811 1596/1239/1103 1540/1300/1120 1800/1500/1280

Sound pressure* dB (A) 34 34 35 36 36 35

Width/Height/Depth mm 904/230/840 904/230/840 904/230/840 904/300/840 904/300/840 904/300/840

Net weight Kg 24 24 24 27.4 27.4 30

Width/Height/Depth (panel) mm 950/55/950 950/55/950 950/55/950 950/46/950 950/46/950 950/46/950

Panel net weight Kg 5 5 5 5 5 5

Liquid pipe diameter mm (inch") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8")

Gas pipe diameter mm (inch") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8")

Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

All AMAZON indoor units accept R-410 A refrigerant.*Sound pressure at low fan speed.

TECHNICAL SPECIFICATIONS

COMPATIBLE WITH

MINI AMAZON2 PIPES

see pag. 182

AMAZON UNITARIO2 PIPES

see pag. 186

AMAZON III PRO3 PIPES

see pag. 196

AMAZON III W2 PIPES

see pag. 192

AMAZON IV PRO2 PIPES

see pag. 190

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

156

AM

AZ

ON

IND

US

TRIA

L V

RF

CONTROLLERS

KC-02.1 H

For further information, please see our Controllers range

KCT-02.1 SR

BMS AND SOFTWARE

CENTRALISEDINDIVIDUAL

KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB

K01-LON K01-BACNET KAYNET CONTROL K01-KNX K01-WIFI

360º AIR DIFFUSION +

DC INVERTER FAN+

K02-MODBUS

KI-02.3 S

(*) RECOMMENDED

KI-02.3 SKC-01 S

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you should add to the € price for the set the price

difference between the recommended controller and the selected controller.ELIGE TU CONTROL

CHOOSE YOUR CONTROL

PRICE LIST

MODEL RECOMMENDED CONTROL PRICE

KCIBF-56 DN3.0 KI-02.3 S £739

KCIBF-71 DN3.0 KI-02.3 S £793

KCIBF-80 DN3.0 KI-02.3 S £848

KCIBF-100 DN3.0 KI-02.3 S £921

KCIBF-112 DN3.0 KI-02.3 S £963

KCIBF-140 DN3.0 KI-02.3 S £1,108

(*) Price calculation based on the recommended controller.

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE INDOOR UNITS

157

The VRF AMAZON Duct units with DC INVERTER fans have a compact and versatile design that allows for adapting to every false ceiling installation. We truly believe this is a thorough product.

• Indoor units with DC INVERTER FAN.

• Broad range of capacities: from 1.5 kW to 14 kW, eleven models in total.

• Double air inlet possibility (rear or lower).

• Fresh air possibility to enter directly into the room through a pre-installation hole located at the unit’s body.

• Included frames for air inlet duct and air outlet duct as standard.

• Compatible with AIRZONE air-conditioning zoning systems.

• It contains a tilted evaporator; it provides a wider exchange area and a compact and reduced height, which facilitates the unit installation in rooms with a limited false ceiling.

• ON/OFF dry contact and 220 V alarm signal output.

• Receiver detaches up to 10 meters (optional cable).

• Possibility to change available static pressure by means of a dip-switch.

• Standard condensation pump.

DUCTSGENERAL CHARACTERISTICS

MODEL KPDF-15 DN3.0

KPDF-22 DN3.0

KPDF-28 DN3.0

KPDF-36 DN3.0

KPDF-45 DN3.0

Cooling capacity kW 1.5 2.2 2.8 3.6 4.5

Cooling capacity Kcal/h 1290 1892 2408 3096 3870

Heating capacity kW 1.7 2.6 3.2 4 5

Heating capacity Kcal/h 1462 2236 2752 3440 4300

Power input kW 0.039 0.039 0.039 0.045 0.058

Indoor airflow m3/h 509/420/370 521/450/380 521/450/380 592/541/426 748/640/550

Static pressure range (rated) Pa 0-30(10) 0-50(10) 0-50(10) 0-50(10) 0-50(10)

Sound pressure* dB (A) 31 31 31 33 33

Width/Height/Depth mm 740/210/500 740/210/500 740/210/500 740/210/500 960/210/500

Net weight Kg 17.5 17.5 17.5 17.5 22.5

Liquid pipe diameter mm (inch") Ø6.35 (1/4") Ø6.35 (1/4") Ø6.35 (1/4") Ø6.35 (1/4") Ø6.35 (1/4")

Gas pipe diameter mm (inch") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2")

Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

All AMAZON indoor units accept R-410 A refrigerant.*Sound pressure at low fan speed.

TECHNICAL SPECIFICATIONS

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

158

AM

AZ

ON

IND

US

TRIA

L V

RF

KCT-02.1 SR

MANUAL PRESSURE ADJUSTMENT AVAILABLE+

DC INVERTER FAN+

MODEL KPDF-56 DN3.0

KPDF-71 DN3.0

KPDF-80 DN3.0

KPDF-90 DN3.0

KPDF-112 DN3. 0

KPDF-140 DN3.0

K P D F - 9 0 DN2.4

Cooling capacity kW 5.6 7.1 8 9 11.2 14

Cooling capacity Kcal/h 4816 6106 6880 7740 9632 12040

Heating capacity kW 6.3 8 9 10 12.5 15.5

Heating capacity Kcal/h 5418 6880 7740 8600 10750 13330

Power input kW 0.089 0.068 0.098 0.108 0.178 0.204

Indoor airflow m3/h 821/640/566 1021/940/778 1290/1090/940 1290/1090/940 1780/1550/1352 1950/1600/1400

Static pressure range (rated) Pa 0-50(10) 0-50(10) 0-100(20) 0-100(20) 0-100(20) 25-150(40)

Sound pressure* dB (A) 33 34 37 37 37 38

Width/Height/Depth mm 960/210/500 1180/210/500 1180/270/775 1180/270/775 1180/270/775 1240/300/865

Net weight Kg 22.5 28 38 40 40 49

Liquid pipe diameter mm (inch") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8")

Gas pipe diameter mm (inch") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8")

Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

(*) RECOMMENDED

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE INDOOR UNITS

159

DUCTS

CONTROLLERS

KC-02.1 H

For further information, please see our Controllers range

KCT-02.1 SR

BMS AND SOFTWARE

CENTRALISEDINDIVIDUAL

KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB

K01-LON K01-BACNET KAYNET CONTROL K01-KNX K01-WIFIK02-MODBUS

KI-02.3 SKC-01 S

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you should add to the € price for the set the price

difference between the recommended controller and the selected controller.ELIGE TU CONTROL

CHOOSE YOUR CONTROL

COMPATIBLE WITH

MINI AMAZON2 PIPES

see pag. 182

AMAZON UNITARIO2 PIPES

see pag. 186

AMAZON III PRO3 PIPES

see pag. 196

AMAZON III W2 PIPES

see pag. 192

AMAZON IV PRO2 PIPES

see pag. 190

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

160

AM

AZ

ON

IND

US

TRIA

L V

RF

KCT-02.1 SR

DC INVERTER FAN+

(*) RECOMMENDED

MANUAL PRESSURE ADJUSTMENT AVAILABLE+

PRICE LISTMODEL RECOMMENDED CONTROL PRICE

KPDF-15 DN3.0 KCT-02.1 SR £461

KPDF-22 DN3.0 KCT-02.1 SR £465

KPDF-28 DN3.0 KCT-02.1 SR £474

KPDF-36 DN3.0 KCT-02.1 SR £492

KPDF-45 DN3.0 KCT-02.1 SR £593

KPDF-56 DN3.0 KCT-02.1 SR £610

KPDF-71 DN3.0 KCT-02.1 SR £661

KPDF-80 DN3.0 KCT-02.1 SR £695

KPDF-90 DN3.0 KCT-02.1 SR £760

KPDF-112 DN3.0 KCT-02.1 SR £848

KPDF-140 DN3.0 KCT-02.1 SR £865

(*) Price calculation based on the recommended controller.

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE INDOOR UNITS

161

DUCTSSTATIC PRESSURE GRAPHS

KPD-15 DN3.0

KPD-22 DN3.0 - KPD-28 DN3.0

KPD-36 DN3.0

Airflow (m3/h)Airflow (m3/h)Airflow (m3/h)

Airflow (m3/h)Airflow (m3/h)Airflow (m3/h)

Airflow (m3/h)Airflow (m3/h)

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

162

AM

AZ

ON

IND

US

TRIA

L V

RF

KPD-45 DN3.0

KPD-56 DN3.0

KPD-71 DN3.0

Airflow (m3/h)Airflow (m3/h)Airflow (m3/h)

Airflow (m3/h)Airflow (m3/h)Airflow (m3/h)

Airflow (m3/h)Airflow (m3/h)Airflow (m3/h)

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE INDOOR UNITS

163

DUCTSSTATIC PRESSURE GRAPHS

KPD-80 DN3.0

KPD-90 DN3.0

Airflow (m3/h)Airflow (m3/h)Airflow (m3/h)

Airflow (m3/h)Airflow (m3/h)Airflow (m3/h)

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

164

AM

AZ

ON

IND

US

TRIA

L V

RF

KPD-112 DN3.0

KPD-140 DN3.0

Airflow (m3/h)Airflow (m3/h)Airflow (m3/h)

Airflow (m3/h)Airflow (m3/h)Airflow (m3/h)

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE INDOOR UNITS

165

As their name suggest, these duct units supply higher static pressure, which allows for a more flexible design. They adapt to every installation space, even those with very high ceilings.

HIGH PRESSURE DUCTS

TECHNICAL SPECIFICATIONS

GENERAL CHARACTERISTICS

MODEL KPDHF-71 DN3.0

KPDHF-90 DN3.0

KPDHF-112 DN3.0

KPDHF-140 DN3.0

KPDHF-160 DN3.0

Cooling capacity kW 7.1 9 11.2 14 16

Cooling capacity Kcal/h 6106 7740 9632 12040 13760

Heating capacity kW 8 10 12.5 16 17

Heating capacity Kcal/h 6880 8600 10750 13760 14620

Power input kW 0.18 0.22 0.38 0.42 0.7

Indoor airflow m3/h 1325/1150/950 1650/1550/1450 2050/1850/1575 2800/2300/1800 3300/2600/2100

Static pressure range (rated) Pa 0-100 (75) 0-100 (75) 0-100 (75) 0-100 (75) 0-100 (75)

Sound pressure* dB (A) 42 45 45 48 50

Width/Height/Depth mm 952/420/690 952/420/690 952/420/690 1300/420/690 1300/420/690

Net weight Kg 41 47 47 68 78

Liquid pipe diameter mm (inch") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8")

Gas pipe diameter mm (inch") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8")

Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

All AMAZON indoor units accept R-410 A refrigerant.*Sound pressure at low fan speed.

• ON/OFF dry contact and 220 V alarm signal output.

• The expansion valve is integrated inside the 16 kW models; models over 20 kW have expansion valve fitted on the side of the unit.

• Compatible with AIRZONE air-conditioning zoning systems.

• Units with high airflows.

• Power range from 7.1 kW to 56 kW.

• Units with a DC INVERTER FAN (a power range from 7.1 kW to 28 kW).

• Condensation pump not included.

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

166

AM

AZ

ON

IND

US

TRIA

L V

RF

MODEL KPDHF-200 DN3.0

KPDHF-250 DN3.0

KPDHF-280 DN3.0

KPDHF-400 DN2.4

KPDHF-450 DN2.4

KPDHF-560 DN2.4

Cooling capacity kW 20 25 28 40 45 56

Cooling capacity Kcal/h 17200 21500 24080 34400 38700 48160

Heating capacity kW 22.5 26 31.5 45 50 63

Heating capacity Kcal/h 19350 22360 27090 38700 43000 54180

Power input kW 0.8 0.8 0.8 2.7 2.7 3.4

Indoor airflow m3/h 4800/3900/3500 4600/4000/3600 4600/4000/3600 7700/6400/5200 7700/6400/5200 10100/8400/7000

Static pressure range (rated) Pa 0-200 (120) 0-200 (120) 0-200 (120) 0-200 (125) 0-200 (125) 0-200 (125)

Sound pressure* dB (A) 50 50 50 56 56 57

Width/Height/Depth mm 1443/470/810 1443/470/810 1443/470/810 1970/668/902.5 1970/668/902.5 1970/668/902.5

Net weight Kg 108 108 108 232 232 235

Liquid pipe diameter mm (inch") ø9.52 (3/8") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2") Ø15.9 (5/8")

Gas pipe diameter mm (inch") Ø22.3 (7/8") Ø22.3 (7/8") Ø22.3 (7/8") Ø28.6 (1 1/8") Ø28.6 (1 1/8") Ø28.6 (1 1/8")

Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x4 (2+T)x4 (2+T)x4

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

FILTER NOT INCLUDED

KCT-02.1 SR

(*) RECOMMENDED

compatible with

HIGH AIRFLOWS+FROM 7.1 KW TO 28 KW DC INVERTER FANS+

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE INDOOR UNITS

167

HIGH PRESSURE DUCTS

CONTROLLERS

KC-02.1 H

For further information, please see our Controllers range

KCT-02.1 SR

BMS AND SOFTWARE

CENTRALISEDINDIVIDUAL

KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEB

K01-LON K01-BACNET KAYNET CONTROL K01-KNX K01-WIFIK02-MODBUS

KI-02.3 SKC-01 S

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER

If you want a different controller, you should add to the € price for the set the price

difference between the recommended controller and the selected controller.ELIGE TU CONTROL

CHOOSE YOUR CONTROL

COMPATIBLE WITH

MINI AMAZON2 PIPES

see pag. 182

AMAZON UNITARIO2 PIPES

see pag. 186

AMAZON III PRO3 PIPES

see pag. 196

AMAZON III W2 PIPES

see pag. 192

AMAZON IV PRO2 PIPES

see pag. 190

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

168

AM

AZ

ON

IND

US

TRIA

L V

RF

compatible with

KCT-02.1 SR(*) RECOMMENDED

HIGH AIRFLOWS+FROM 7.1 KW TO 28 KW DC INVERTER FANS+

(*) Price calculation based on the recommended controller.

PRICE LISTMODEL RECOMMENDED CONTROL PRICE

KPDHF-71 DN3.0 KCT-02.1 SR £770

KPDHF-90 DN3.0 KCT-02.1 SR £861

KPDHF-112 DN3.0 KCT-02.1 SR £915

KPDHF-140 DN3.0 KCT-02.1 SR £963

KPDHF-160 DN3.0 KCT-02.1 SR £1,010

KPDHF-200 DN3.0 KCT-02.1 SR £1,377

KPDHF-250 DN3.0 KCT-02.1 SR £1,408

KPDHF-280 DN3.0 KCT-02.1 SR £1,438

KPDHF-400 DN2.4 KCT-02.1 SR £2,456

KPDHF-450 DN2.4 KCT-02.1 SR £2,571

KPDHF-560 DN2.4 KCT-02.1 SR £2,690

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE INDOOR UNITS

169

This is an interface that allows you to connect a UTA (air terminal unit) with a direct-expansion heat exchanger to the VRF system. This unit shall be treated like an additional indoor unit within the VRF system.

• It allows for installing direct expansion heat exchangers of up to 56kW.

• It consists of an electrical control box, electronic expansion valve, cables and control sensors.

• It includes an XYE port to connect to a centralised indoor unit control.

• ON/OFF dry contact and 220 V alarm signal output.

• Compatible only with 2 pipes outdoor units.

• More than one unit can be connected at the same time to increase the connectable capacity.

KAHU

GENERAL CHARACTERISTICS

TECHNICAL SPECIFICATIONS

MODEL KAHU-200.2 KAHU-360.2 KAHU-560.2

Cooling capacity* kW From 9 to 20 From 21 to 36 From 37 to 56

Width/Height/Depth mm 350/375/150 350/375/150 350/375/150

Net weight Kg 8.4 8.7 8.9

Liquid pipe diameter inlet mm (inch") ø9.52 (3/8") Ø12.7 (1/2") Ø15.9 (5/8")

Liquid pipe diameter outlet mm (inch") ø9.52 (3/8") Ø12.7 (1/2") Ø15.9 (5/8")

Power cord (10 m max.) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5

Power supply V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50

* Capacity can be adjusted by a dip switch located at the electric board.

NEW

COMPATIBLE WITH

AMAZON UNITARIO2 PIPES

see pag. 186

AMAZON III W2 PIPES

see pag. 192

AMAZON IV PRO2 PIPES

see pag. 190

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

170

AM

AZ

ON

IND

US

TRIA

L V

RF

KCT-02.1 SR

ELECTRIC EXPANSION VALVE4

1 KCT-02.1 SR BUILT-IN WIRED CONTROLELECTRICAL CONTROL BOX2

TEMPERATURE SENSORS AND CABLES3

INSTALLATION EXAMPLE

STANDARD

BMS AND SOFTWARE CENTRALISED

KCC-16 KCCT-64 I KCC-64 I-PS KCC-64 WEBK01-LON K02-MODBUS K01-BACNET KAYNET CONTROL K01-KNX K01-WIFI

KAHU

MARKET CLIMATE CONTROL

INDOOR UNITS

OUTDOOR UNIT

PQE

WITH DIRECT EXPANSION BATTERY

Liquid cooling pipeline

Gas cooling pipeline

PRICE LIST

MODEL STANDARD CONTROLLER PRICE

KAHU-200.2 KCT-02.1 SR £308

KAHU-360.2 KCT-02.1 SR £369

KAHU-560.2 KCT-02.1 SR £492

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE INDOOR UNITS

171

KAYSUN UK introduces the DOMESTIC HOT WATER RECOVERY KIT. It is an indoor unit specially designed for the AMAZON III PRO 3 pipes systems with heat recovery able to produce domestic hot water.

• Compatible with AMAZON III PRO 3 pipes units only.

• Water outlet temperature between 25ºC and 45ºC.

DOMESTIC HOT WATER RECOVERY KIT

GENERAL CHARACTERISTICS

TECHNICAL SPECIFICATIONS

MODEL KWF-140 ACS

Heating capacity kW 14

Heating capacity Kcal/h 12040

Power consumption kW 0.01

Water outlet temperature range ºC 25-45

Outdoor temperatures limits working in cooling mode ºC -5ºC to 35ºC

Outdoor temperatures limits working in heating mode ºC -15ºC to 35ºC

Water inlet pipe diameter Inches DN25

Water outlet pipe diameter Inches DN25

Design airflow m³/h 2.4 (from 2 to 3)

Liquid pipe diameter mm (inch") ø9.52 (3/8")

Gas pipe diameter mm (inch") Ø15.9 (5/8")

Sound pressure dB (A) 26

Width/Height/Depth mm 500/900/373

Net weight Kg 55

Power cord (10 m max.) mm2 (2+T)x2.5

Shielded communication wires mm2 3x1.5

Power supply V / F / Hz 220-240/1/50

COMPATIBLE WITH

AMAZON III PRO3 PIPES

see pag. 196

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

172

AM

AZ

ON

IND

US

TRIA

L V

RF

AMAZON III PRO 3 PIPES OUTDOOR UNITDOMESTIC HOT WATER RECOVERY KIT

INDOOR UNIT

INSTALLATION EXAMPLE

KVBM2-DN3

DOMESTIC HOT WATER

KVBM2-DN3

DOMESTIC HOT WATER+

PRICE LIST

MODEL PRICE

KWF-140 ACS £862

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

173

OUTDOOR UNITS

FEATURES

INDUSTRIAL VRF RANGE

174

POWER RANGE

2 PIPES

MINI AMAZON VRF

AMAZON UNITARIO

AMAZON IV PRO

SINGLE-PHASE

SIDE AIR DISCHARGE

TOP AIR DISCHARGE

KMF-80 DVN3 KMF-105 DVN3 KMF-120 DVN2

KMF-120 DTN2

KMF-140 DVN2

KMF-140 DTN2

KMF-160 DVN2

KMF-160 DTN2 KMF-180 DTN2

AMAZON III W

AMAZON III PRO

THREE-PHASE

POWER kW

OUTDOOR UNITS

FULL DC INVERTER

FULL DC INVERTER

8.0 10.5 12.0 14.0 16.0 18.0

3 PIPES POWER kW 8.0 10.5 12.0 14.0 16.0 18.0

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

175

AM

AZ

ON

IND

US

TRIA

L V

RF

COMBINABLE UP TO 4 MODULES

KMF-200 DN2 KMF-224 DN2

K2F-252 DN4 S

KMF-260 DN2

K2UF-280 DN3

K2F-280 DN4 S

K2UF-335 DN3

K2F-280 DN4 S

COMBINABLE UP TO 3 MODULES

K2F-252 DN3W K2F-280 DN3W K2F-335 DN3W

K2UF-400 DN3

K2F-400 DN4 S

KMF-400 DN3

K2UF-450 DN3

K2F-450 DN4 S

KMF-450 DN3

K2UF-560 DN3

K2F-560 DN4 S

K2UF-615 DN3 K2UF-670 DN3

K2F-615 DN4 SK2F-500 DN4 S

COMBINABLE UP TO 4 MODULES

K3F-252 DN3 S K3F-280 DN3 S K3F-335 DN3 S K3F-400 DN3 S K3F-450 DN3 S

20.0 22.4 25.2 26.0 28.0 33.5 40.0 45.0 50.0 56.0 61.5 67.0

20.0 22.4 25.2 26.0 28.0 33.5 40.0 45.0 50.0 56.0 61.5 67.0

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE

176

OUTDOOR UNITS - 2 PIPES

AMAZON IV PRO

KAYSUN UK continues to focus on its AMAZON IV PRO range. All the compressors and fans of this range are DC INVERTER, a feature that turns this new model into a FULL DC INVERTER. Furthermore, unlike previous ranges, these units are fitted with 2 additional modules, thereby allowing for more combinations. Now we have 8 modules from 8HP to 22HP, which are available to combine up to 88 HP (4 modules maximum). We would like to highlight this range's novel and dynamic design, unique on the market, which compared to previous models, allows for installing the units in smaller spaces according to their capacity. As is always the case, depending on the type of combination, the units of this new range allow us to connect up to 64 indoor units. However, some of the most outstanding features of previous models have been kept for this new range, such as: Delta-shaped heat exchangers that enhance subcooling and allow for longer installation distances, auto-addressing function, up to 150% simultaneity, silent ventilation and 40Pa available pressure in fan motors.

AMAZON UNITARIO

AMAZON UNITARIO, the KAYSUN UK range of non-combinable units, has 7 units with 28kW to 67kW top air discharge and up to 40Pa available pressure, and 5 side air discharge units from 20kW to 45kW. This INVERTER technology single solution of KAYSUN UK allows for combining up to 39 indoor units and a 200 metres maximum installation distance between the outdoor unit and the furthest indoor unit. This unit also provides up to 150% simultaneity, highly efficient compressors, a silent ventilation system and a rotary electric box in 20, 22 and 24 HP modules. This is a very thorough and competitive product.

2 PIPESVRF OUTDOOR UNITS

FULL DC INVERTER+

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

177

AM

AZ

ON

IND

US

TRIA

L V

RF

MINI AMAZON VRF

The 2-pipe MINI AMAZON generation with DC Inverter compressor and fan motor keeps its 9 models. The design of fan´s blades and grille, as well as the DC Inverter technology used therein and in the “Twin Rotary“ compressor motor, provides the unit with outstanding energy efficiency and work range. KAYSUN UK seeks to provide versatility and total freedom, adding up to 9 indoor units to the combinations of the MINI AMAZON range and expanding the cooling distances up to 60 meters of actual overall length. Outdoor units automatically distribute the address to indoor units with no manual adjustment. In addition, the cooling pipeline of the 12, 14, 16 and 18 kW models can be installed in 4 different positions, thereby making installation easier. Moreover, the XYE port in the outdoor unit's board allows for the connection of the centralised control panel of indoor unit directly to the outdoor unit.

AMAZON III W

AMAZON III W range of 2 water condensed pipes with DC INVERTER compressors stands out from the whole range because of its modular design, which supports combinations up to 36 HP through the combination of 3 basic modules of 8-10-12 HP with which you can install up to a maximum of 59 indoor units. The structure of the new unit is much more compact and lightweight compared to the AMAZON air-condensed outdoor units. Thanks to its small size and the possibility of vertical installation (one outdoor on top of the other due to the lack of fans) allows it to be installed in very tight spaces.The lack of fans obviously reduces the sound pressure levels of outdoor units. Furthermore, due to the savings on consumption resulting from the lack of fans, energy efficiency notably increases if compared to the AMAZON air-condensed system, making it one of the strengths of the AMAZON III W.

The AMAZON range offers a wide variety of installation possibilities of indoor units with different ranges of cooling capacity, thereby allowing for the installation of 64 indoor units maximum, depending on the outdoor unit model or combinations thereof. This combination flexibility allows it to adapt to a wide variety of projects. One solution for every single need. KAYSUN's VRF system allows for installations with 50 % to 150% concurrence.

AMAZON equipment allows for designing and arranging an entire cooling and heating system with greater flexibility. The planning and design difficulty inherent to air-conditioning projects in complex or large buildings are made simple thanks to the long pipes distance and height provided by our range of products.

Wall Double flow console Art flux 360º cassette

OUTDOOR UNIT

Exposed floor unit Duct High pressure duct

INDOOR UNITS

64 UP TO 64 INDOOR UNITS

MULTIPLE COMBINATIONS

SYSTEMS WITH LONG DISTANCE COOLING PIPELINES

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE

178

OUTDOOR UNITS - 2 PIPES

MINI AMAZON II SINGLE-PHASE

MODEL KMF-80 DVN3 KMF-105 DVN3 KMF-120 DVN2 KMF-140 DVN2 KMF-160 DVN2

Cooling capacity kW 8.0 10 12.3 14.0 15.5

Cooling capacity Kcal/h 6880 8600 10578 12040 13330

Cooling input kW 2.05 2.30 3.25 3.95 4.52

Heating capacity kW 8.4 10.5 13.2 15.4 17.00

Heating capacity Kcal/h 7224 9030 11352 13244 14620

Heating input kW 1.79 2.27 3.47 4.16 4.77

SEER 5.1 5.2 7.1 6.68 6.42

SCOP 3.8 3.8 4.11 3.96 3.83

Amount of connectable indoor units 4 5 6 6 7

Power supply V / F / Hz 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50

Inverter compressor 1 1 1 1 1

Fans 1 1 2 2 2

Liquid pipe diameter mm (Inch) Ø9.53 (3/8") Ø9.53 (3/8") Ø9.53 (3/8") Ø9.53 (3/8") Ø9.53 (3/8")

Gas pipe diameter mm (inches) Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø19.1 (3/4")

Refrigerant type R-410A R-410A R-410A R-410A R-410A

Refrigerant factory charge gr 2800 2950 3300 3900 3900

Airflow m3/h 3600 5100 6000 6000 6000

Width/Height/Depth mm 990/966/336 990/966/336 900/1327/320 900/1327/320 900/1327/320

Net weight Kg 62 72 95 95 100

Sound pressure dB (A) 56 57 54 54 54

Power cord (under 20 metres) mm2 (2+T)x2.5 (2+T)x4 (2+T)x4 (2+T)x6 (2+T)x6

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5

Cooling mode outdoor operation range

Cº -15 to 48 -15 to 48 -15 to 48 -15 to 48 -15 to 48

Heating mode outdoor operation range Cº -20 to 48 -20 to 48 -20 to 48 -20 to 48 -20 to 48

TECHNICAL SPECIFICATIONS

BRANCH PIPES

MODEL PRICE

KCMI 112 (KCMI100 + KCMI200) £46

BRANCH PIPES PRICE LIST

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

179

AM

AZ

ON

IND

US

TRIA

L V

RF

8 / 10.5

The MINI AMAZON II VRF system is ideal to meet the needs in small industrial environments. Its direct-expansion technology for 2 pipes aircooled covers a range of cooling capacities from 8 up to 26 kW in single-phase models.

• Depending on the model, single-phase units accept up to 7 indoor units.

• It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.

• Since it is fitted with side air discharge, it does not require much space for installation or maintenance.

• The entire range works only with DC Inverter compressors and fans, which provides it with remarkable energy efficiency and low consumption and sound levels.

• Compressor with highly-efficiency double eccentric Twin Rotary DC Inverter with environmentally friendly refrigerant R410A.

• It includes a auto-addressing feature for indoor units.

• The outdoor unit includes the XYE port to communicate with the centralised control panel of indoor units.

• The cooling pipeline of 12, 14 and 16kW models may be installed in 4 different positions, thereby facilitating their installation.

• Up to 70 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).

GENERAL CHARACTERISTICS

12 / 14 / 16

UP TO 7 INDOOR UNITS +

DC INVERTER COMPRESSOR AND FAN+ERP

PRICE LIST

MODEL PRICE

KMF-80 DVN3 £1,708

KMF-105 DVN3 £2,230

KMF-120 DVN2 £2,381

KMF-140 DVN2 £2,450

KMF-160 DVN2 £2,576

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE

180

OUTDOOR UNITS - 2 PIPES

MINI AMAZON II THREE-PHASE

MODEL KMF-120 DTN2 KMF-140 DTN2 KMF-160 DTN2 KMF-180 DTN2

Cooling capacity kW 12.3 14.0 15.5 17.5

Cooling capacity Kcal/h 10578 12040 13330 15050

Cooling input kW 3.25 4.08 4.52 5.60

Heating capacity kW 13.2 15.4 17.0 19.0

Heating capacity Kcal/h 11352 13244 14620 16340

Heating input kW 3.47 4.12 4.77 5

SEER 7.1 6.68 6.42 6.21

SCOP 4.11 3.96 3.83 3.92

Amount of connectable indoor units 6 6 7 9

Power supply V / F / Hz 380-400 / 3 / 50 380-400 / 3 / 50 380-400 / 3 / 50 380-400 / 3 / 50

Inverter compressor 1 1 1 1

Fans 2 2 2 2

Liquid pipe diameter mm (Inch) Ø9.53 (3/8") Ø9.53 (3/8") Ø9.53 (3/8") Ø9.53 (3/8")

Gas pipe diameter mm (inches) Ø15.9 (5/8") Ø15.9 (5/8") Ø19.1 (3/4") Ø19.1 (3/4")

Refrigerant type R-410A R-410A R-410A R-410A

Refrigerant factory charge gr 3300 3900 3900 4500

Airflow m3/h 6000 6000 6000 6800

Width/Height/Depth mm 900/1327/320 900/1327/320 900/1327/320 900/1327/320

Net weight Kg 95 95 102 107

Sound pressure dB (A) 57 57 57 59

Power cord (under 20 metres) mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5

Cooling mode outdoor operation range Cº -15 to 48 -15 to 48 -15 to 48 -15 to 48

Heating mode outdoor operation range Cº -20 to 48 -20 to 48 -20 to 48 -20 to 48

TECHNICAL SPECIFICATIONS

BRANCH PIPES

MODEL PRICE

KCMI 112 (KCMI100 + KCMI200) £46

BRANCH PIPES PRICE LIST

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

181

AM

AZ

ON

IND

US

TRIA

L V

RF

GENERAL CHARACTERISTICS

The MINI AMAZON II VRF system is ideal to meet the needs in small industrial environments. Its direct-expansion technology for 2 pipes aircooled covers a range of cooling capacities from 12 up to 18 kW in three-phase models.

• Depending on the model, three-phase units accept up to 9 indoor units.

• It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.

• Since it is fitted with side air discharge, it does not require much space for installation or maintenance.

• The entire range works only with DC Inverter compressors and fans, which provides it with remarkable energy efficiency and low consumption and sound levels.

• Compressor with highly-efficiency double eccentric Twin Rotary DC Inverter with environmentally friendly refrigerant R410A.

• It includes an auto-addressing feature for indoor units.

• The outdoor unit includes the XYE port to communicate with the centralised control panel of indoor units.

• The cooling pipeline of 12, 14, 16 and 18 kW models may be installed in 4 different positions, thereby facilitating their installation.

• Up to 70 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).

UP TO 12 INDOOR UNITS +

DC INVERTER COMPRESSOR AND FAN+

12 / 14 / 16 / 18

PRICE LIST

MODEL PRICE

KMF-120 DTN2 £2,381

KMF-140 DTN2 £2,450

KMF-160 DTN2 £2,576

KMF-180 DTN2 £2,821

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE

182

OUTDOOR UNITS - 2 PIPES

SIDE AIR DISCHARGEAMAZON UNITARIO

MODEL KMF-200 DN2 KMF-224 DN2 KMF-260 DN2 KMF-400 DN3 KMF-450 DN3

Cooling capacity kW 20.0 22.4 26.0 40.0 45.0

Cooling capacity Kcal/h 17200 19264 22360 34400 38700

Cooling input kW 6.10 6.80 7.60 11.90 13.60

Heating capacity kW 22.0 24.5 28.5 45.0 50.0

Heating capacity Kcal/h 18920 21070 24510 38700 43000

Heating input kW 6.10 5.90 6.80 11.10 12.70

SEER 6.19 6.21 6.42 6.26 6.2

SCOP 3.76 3.97 4.05 5.33 5.2

Amount of connectable indoor units 10 11 12 14 15

Power supply V / F / Hz 380-400 / 3 / 50 380-400 / 3 / 50 380-400 / 3 / 50 380-400 / 3 / 50 380-400 / 3 / 50

Inverter compressors 1 1 1 2 2

Fans 2 2 2 2 2

Liquid pipe diameter mm (Inch) Ø9.53 (3/8") Ø9.53 (3/8") Ø9.53 (3/8") Ø12.7 (1/2") Ø12.7 (1/2")

Gas pipe diameter mm (Inch) Ø19.1 (3/4") Ø19.1 (3/4") Ø22.2 (7/8") Ø22.2 (7/8") Ø25.4 (1")

Refrigerant type R-410A R-410A R-410A R-410A R-410A

Refrigerant factory charge gr 4800 6200 6200 9000 12000

Airflow m3/h 10999 10494 10494 16575 16575

Width/Height/Depth mm 1120/1558/400 1120/1558/400 1120/1558/400 1360/1650/540 1360/1650/540

Net weight Kg 137 146 147 240 275

Sound pressure dB (A) 59 59 60 62 62

Power cord (under 20 metres) mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x10 (4+T)x16

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5

Cooling mode outdoor operation range Cº -15 to 48 -15 to 48 -15 to 48 -5 to 48 -5 to 48

Heating mode outdoor operation range Cº -20 to 48 -20 to 48 -20 to 48 -15 to 24 -15 to 24

TECHNICAL SPECIFICATIONS

BRANCH PIPES

MODEL PRICE

KCMI 112 (KCMI100 + KCMI200) £46

KCMI 212 (KCMI100 + KCMI200) £71

KCMI 312 (KCMI100 + KCMI200) £86

KCMI 412 (KCMI100 + KCMI200) £108

KCMI 512 (KCMI100 + KCMI200) £474

BRANCH PIPES PRICE LIST

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

183

AM

AZ

ON

IND

US

TRIA

L V

RF

GENERAL CHARACTERISTICS

• Depending on the model, they accept up to 15 indoor units.

• It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.

• Since it is fitted with side air discharge, it does not require much space for installation or maintenance.

• The entire range works only with Twin Rotary DC Inverter compressors and DC Inverter fans, which provides it with remarkable energy efficiency and low consumption and sound levels.

• Night mode is included as an option in order to reduce the sound level of outdoor units.

• It includes an auto-addressing feature for indoor units.

• The outdoor unit includes the XYE port to communicate with the centralised control panel of indoor units.

• Up to 120 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).

INVERTER COMPRESSORS AND FANS+

UP TO 15 INDOOR UNITS+

20 / 22 / 26 / 40 / 45

The AMAZON SINGLE SIDE DISCHARGE range has non-combinable external VRF units of between 20 kW and 45 kW. The big advantage of these units is the possibility to install higher power equipments in confined spaces.

PRICE LIST

MODEL PRICE

KMF-200 DN2 £3,261

KMF-224 DN2 £3,669

KMF-260 DN2 £3,832

KMF-400 DN3 £5,736

KMF-450 DN3 £6,540

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE

184

OUTDOOR UNITS - 2 PIPES

TOP AIR DISCHARGEAMAZON UNITARIO

TECHNICAL SPECIFICATIONS

MODEL K2UF-280 DN3

K2UF-335 DN3

K2UF-400 DN3

K2UF-450 DN3

K2UF-560 DN3

K2UF-615 DN3

K2UF-670 DN3

Rated HP 10 12 14 16 20 22 24

Cooling capacity kW 28 33.5 40 45 56 61.5 67

Cooling capacity Kcal/h 24080 28810 34400 38700 48160 52890 57620

Cooling input kW 7.19 9.05 12.30 14.01 17.00 18.80 20.80

Heating capacity kW 32 38 45 50 63 69 75

Heating capacity Kcal/h 27090 32250 38700 43000 54180 59340 64500

Heating input kW 7.60 8.99 11.20 12.80 16.00 17.90 19.80

SEER 6.83 6.58 6.18 6.05 6.22 6.03 5.92

SCOP 5.94 5.95 5.52 5.29 5.32 5.27 5.04

Amount ofconnectable indoor units 16 16 16 20 33 36 39

Power supply V / F / Hz 380 / 3 / 50 380 / 3 / 50 380 / 3 / 50 380 / 3 / 50 380 / 3 / 50 380 / 3 / 50 380 / 3 / 50

Inverter compressor 1 1 1 1 1 1 1

Fixed Scroll compressors 0 1 2 2 2 2 2

Fans 1 2 2 2 2 2 2

Liquid pipe diameter mm (Inch) Ø12.7 (1/2") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø19.1 (3/4") Ø19.1 (3/4") Ø19.1 (3/4")

Gas pipe diameter mm (Inch) Ø25.4 (1") Ø31.8 (1 1/4") Ø31.8 (1 1/4") Ø31.8 (1 1/4") Ø31.8 (1 1/4") Ø31.8 (1 1/4") Ø31.8 (1 1/4")

Refrigerant type R-410 A R-410 A R-410 A R-410 A R-410 A R-410 A R-410 A

Refrigerant factory charge gr 10000 12000 15000 15000 17000 18500 18500

Airflow m3/h 11,000 15,000 15,000 15,000 18,000 22,100 22,100

Static Pressure Pa 40 40 40 40 40 40 40

Width/Height/Depth mm 960/1615/765 1250/1615/765 1250/1615/765 1250/1615/765 1390/1615/765 1585/1615/765 1585/1615/765

Net weight Kg 205 275 325 325 360 385 390

Sound pressure dB (A) 58 58 60 60 62 63 63

Power cord(under 20 metres) mm2 (4+T)*4 (4+T)*6 (4+T)*10 (4+T)*16 (4+T)*16 (4+T)*25 (4+T)*25

Communication wiring mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5

Cooling mode outdoor operation range Cº -5 to 48 -5 to 48 -5 to 48 -5 to 48 -5 to 48 -5 to 48 -5 to 48

Heating mode outdoor operation range Cº -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 27 -20 to 27 -20 to 27

BRANCH PIPES

MODEL PRICE £

KCMI 112 (KCMI100 + KCMI200) £46

KCMI 212 (KCMI100 + KCMI200) £71

KCMI 312 (KCMI100 + KCMI200) £86

KCMI 412 (KCMI100 + KCMI200) £108

KCMI 512 (KCMI100 + KCMI200) £474

BRANCH PIPES PRICE LIST

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

185

AM

AZ

ON

IND

US

TRIA

L V

RF

GENERAL CHARACTERISTICS

Direct-expansion system for 2 pipes aircooled pipes designed for 28 kW to 67 kW cooling capacity units. It is ideal for air-conditioning large spaces that require the creation of atmospheres with different temperatures.

• Individual (non-combinable) outdoor units with capacity ranging from 10 to 24 HP (7 models). This system is able to combine between 16 and 39 indoor units.

• It admits a 50% to 150% simultaneity index of the outdoor unit's power.

• Fitted with a top air discharge system, this range is able to make air circulates through the condensation system thanks to the 40 Pa available pressure supplied by its DC Inverter fan.

• Night mode is included as an option in order to reduce the sound level of outdoor units.

• Highly-efficiency scroll and fixed DC Inverter compressors with environmentally friendly R410A refrigerant.

• Night mode is included as an option in order to reduce the sound level of outdoor units.

• Up to 175 metres of actual length for the pipes connecting the outdoor unit with the farthest indoor unit.

NON-COMBINABLE SYSTEMS +

UP TO 39 INDOOR UNITS+

PRICE LIST

MODEL PRICE

K2UF-280 DN3 £4,611

K2UF-335 DN3 £5,711

K2UF-400 DN3 £6,490

K2UF-450 DN3 £7,005

K2UF-560 DN3 £8,714

K2UF-615 DN3 £9,481

K2UF-670 DN3 £10,046

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES

33

AMAZON IV PRO TECHNICAL SPECIFICATIONS

MODEL K2F-252 DN4S

K2F-280 DN4S

K2F-335 DN4S

K2F-400 DN4S

K2F-450 DN4S

K2F-500 DN4S

K2F-560 DN4S

K2F-615 DN4S

Capacity HP 8 10 12 14 16 18 20 22

Cooling capacity kW 25.2 28 33.5 40 45 50 56 61.5

Cooling capacity Kcal/h 21672 24080 28810 34400 38700 43000 48160 52890

Cooling input kW 5.79 7.02 8.71 10.81 12.83 14.47 16.67 18.77

Heating capacity kW 27 31.5 37.5 45 50 56 63 69

Heating capacity Kcal/h 23220 27090 32250 38700 43000 48160 54180 59340

Heating input kW 5.8 7.2 8.8 11.0 12.47 14.15 15.98 17.86

SEER 8.25 7.9 7.54 7.54 7.2 7.36 7.28 7.04

SCOP 6.52 6.35 6.13 6.03 5.82 5.67 5.5 5.25

Amount of connectable indoor units

13 16 19 23 26 29 33 36

Power supply V / F / Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50

Inverter compressor 1 1 1 2 2 2 2 2

Fans 1 1 1 2 2 2 2 2

Oil balance pipe diameter mm (Inch) Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4")

Liquid pipe diameter mm (Inch) Ø9.53 (3/8") Ø9.53 (3/8") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8")

Gas pipe diameter mm (Inch) Ø22.2 (7/8") Ø22.2 (7/8") Ø25.4 (1") Ø25.4 (1") Ø28.6 (1 1/8") Ø28.6 (1 1/8") Ø28.6 (1 1/8") Ø28.6 (1 1/8")

Refrigerant type R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A

Refrigerant factory charge gr 9000 9000 11000 13000 13000 13000 16000 16000

Airflow m3/h 12000 12000 12000 14000 14000 16000 16000 16000

Static Pressure Pa 40 40 40 40 40 40 40 40

Width/Height/Depth

mm 990/1635/790 990/1635/790 990/1635/790 1340/1635/790 1340/1635/790 1340/1635/790 1340/1635/790 1340/1635/790

Net weight Kg 219 219 237 297 297 305 340 340

Sound pressure dB (A) 58 59 60 62 62 63 63 63

Power cord(under 20 metres) mm2 (4+T)x2.5 (4+T)x4 (4+T)x6 (4+T)x10 (4+T)x16 (4+T)x16 (4+T)x16 (4+T)x16

Communication wiring

mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5

Cooling mode outdoor operation range

Cº From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48

Heating mode outdoor operation range

Cº From -20 to 24

From -20 to 24

From -20 to 24

From -20 to 24

From -20 to 24

From -20 to 24

From -20 to 24

From -20 to 24

BRANCH PIPES PRICE LISTBRANCH PIPES OUTDOOR MODULES BRANCH PIPES

MODEL PRICE

KCME 12 £123

KCME 13 £197

KCME 14 £351

MODEL PRICE

KCMI 112 (KCMI100 + KCMI200) £46

KCMI 212 (KCMI100 + KCMI200) £71

KCMI 312 (KCMI100 + KCMI200) £86

KCMI 412 (KCMI100 + KCMI200) £108

KCMI 512 (KCMI100 + KCMI200) £474

Design and Install for you

187

AM

AZ

ON

IND

US

TRIA

L V

RF

Direct-expansion system for 2 pipes aircooled designed for 25.2 kW to 246 kW cooling power units. Ideal for meeting the needs in medium and large industrial environments.

• This range is equipped with high capacity Scroll DC Inverter compressors and environmentally friendly R410A refrigerant. These features make these units even more efficient than previous models.

• The new design of the fan's blades and protection grille reduces sound levels and increase airflow. Modular design with the option of combining the 8 individual modules (8-10-12-14-16-18-20 and 22 HP) up to 88 HP (4 modules maximum).

• The 12, 20 and 22 HP models are smaller if compared to previous versions because we use an extra 21% of heat exchanger's surface.

• Standard automatic redundancy between modules. It balances and extends the working life of the compressors of each module, whether of the Master unit or any of the Slaves.

• They allow for combinations containing up to 64 indoor units.

• It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.

• Fitted with a top air discharge system, this range is able to make air circulates through the condensation system thanks to the 40 Pa available pressure supplied by its DC Inverter fan.

• Delta-shaped heat exchanger; it enhances subcooling values up to 12ºC and improves the exchanger's efficiency.

• Up to 200 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).

GENERAL CHARACTERISTICS

8 / 10 / 12 14 / 16 / 18 / 20 / 22

UP TO 64 INDOOR UNITS +

FULL DC INVERTER+

PRICE LIST

MODEL PRICE

K2F-252 DN4S £5,654

K2F-280 DN4S £5,969

K2F-335 DN4S £6,785

K2F-400 DN4S £7,854

K2F-450 DN4S £8,168

K2F-500 DN4S £9,173

K2F-560 DN4S £10,178

K2F-615 DN4S £11,184

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE

188

OUTDOOR UNITS - 2 PIPES

AMAZON III W

MODEL K2F-252 DN3W K2F-280 DN3W K2F-335 DN3W

Capacity HP 8 10 12

Cooling capacity kW 25.2 28 33.5

Cooling capacity Kcal/h 21672 24080 28810

Cooling input kW 4.8 6.1 8

Heating capacity kW 27 31.5 37.5

Heating capacity Kcal/h 23220 27090 32250

Heating input kW 4.5 5.8 7.8

Amount of connectable indoor units 13 16 19

Power supply V / F / Hz 380-415/3/50 380-415/3/50 380-415/3/50

Inverter compressor 1 1 1

Heat exchanger type Shell and tube Shell and tube Shell and tube

Water flow rate m3/h 5.4 6.0 7.2

Load loss kPa 35 40 48

Water pipe max. pressure Mpa 1.98 1.98 1.98

Water inlet pipe diameter DN32 DN32 DN32

Water outlet pipe diameter DN32 DN32 DN32

Oil balance pipe diameter mm (Inch) Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4")

Liquid pipe diameter mm (Inch) Ø12.7 (1/2") Ø12.7 (1/2") Ø15.9 (5/8")

Gas pipe diameter mm (Inch) Ø25.4 (1") Ø25.4 (1") Ø31.8 (1 1/4")

Refrigerant type R-410A R-410A R-410A

Refrigerant factory charge gr 2000 2000 2000

Width/Height/Depth mm 780/1000/550 780/1000/550 780/1000/550

Net weight Kg 146 146 146

Sound pressure dB (A) 51.0 52.0 52.0

Power cord (under 20 metres) mm2 (4+T)x2.5 (4+T)x4 (4+T)x6

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5

Water inlet temperature range Cº From 7 to 45 From 7 to 45 From 7 to 45

TECHNICAL SPECIFICATIONS

BRACH PIPES PRICE LIST

BRANCH PIPES OUTDOOR MODULES BRANCH PIPES

MODEL PRICE

KCMI 112 (KCMI100 + KCMI200) £46

KCMI 212 (KCMI100 + KCMI200) £71

KCMI 312 (KCMI100 + KCMI200) £86

KCMI 412 (KCMI100 + KCMI200) £108

KCMI 512 (KCMI100 + KCMI200) £474

MODEL PRICE

KCME 12 £123

KCME 13 £197

KCME 14 £351

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

189

AM

AZ

ON

IND

US

TRIA

L V

RF

Direct-expansion system for 2 pipes watercooled designed for 25.2 kW to 100.5 kW cooling capacity units. Ideal for meeting the needs in medium and large industrial environments.

• This range is equipped with high capacity Scroll DC Inverter compressors and environmentally friendly R410A refrigerant. These features make these units a very efficient product.

• Modular design with the option of combining the 3 individual modules (8-10-12 HP) up to 36 HP (3 modules maximum).

• Shell and tube heat exchanger and highly-efficient cross airflow.

• Standard automatic redundancy between modules. It balances and extends the working life of the compressors of each module, whether of the Master unit or any of the Slaves.

• They allow for combinations containing up to 59 indoor units.

• It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.

• Because of the lack of fans, this system is more efficient that aircooled systems and provides low consumption and sound levels.

• Compared to previous aircooled outdoor units, this outdoor unit is more compact and lightweight and provides a significant reduction in weight, area and volume.

• Up to 150 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).

WATERCOOLED

GENERAL CHARACTERISTICS

UP TO 59 INDOOR UNITS +

PRICE LIST

MODEL PRICE

K2F-252 DN3W £5,497

K2F-280 DN3W £6,126

K2F-335 DN3W £7,162

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE

190

OUTDOOR UNITS - 3 PIPES

VRF OUTDOOR UNITS

• New ventilation system One fan with 3 blades and a second fan with 4 blades

• AMAZON III PRO Full DC Inverter

• Compact and lightweight• Easy transport and installation. • Rotating electrical box

• DOUBLE SUBCOOLING: Condenser heat exchanger in delta form

• Subcooling takes place in exchanger.

FULL DC INVERTER

• 5 available modules from 25,2 kW to 45 kW• Up to 4 combinable modules (180 kW)• Up to 64 combinable indoor units • Optimized fan design• Better energy efficiency • Working range between -5º C and 48ºC in cool

mode and between -20ºC and 24ºC in heat mode

LONG DISTANCE COOLING PIPES1000 m

AMAZON III PRO

CONTINUOUS HEATING during defrosting

3 PIPES

CONTINUOUS HEATING DURING DEFROSTING

Thanks to double condenser, defrost is made in the first heat exchanger. Once it is finished, the same operation is realized in the second one. This way, all indoor units are kept in heating mode during the entire process. At the same time, the unit can work with a single condenser to compensate for the highest load of the system both in cold and heat, which represents substantial energy savings and remarkable energy efficiency in the cooling circuit.

DOUBLE SUBCOOLINGAMAZON III PRO 3 pipes has a dual system of liquid subcooling that increases the system's energy efficiency. The delta-shaped heat exchanger reduces its load loss by increasing liquid proportion and therefore, arranging longer pipeline lengths. Thanks to this subcooling technology, liquid temperatures at the condenser outlet may reach up to 37.1ºC.

The second stage of the subcooling process is carried out in each series inverter box since, thanks to a small liquid by-pass pipe, subcooling temperature may reach 22.1ºC.OPTIMISED FAN DESIGN

New ventilation system: one fan fitted with 3 blades and a second fan fitted with 4 blades. This reduces the effect of acoustic resonance that directly affects the noise level of the outdoor unit.

MAINTENANCE

Thanks to the rotary electrical box, the cooling circuit can be accessed more easily for maintenance and installation. At the same time, the electrical box is fitted with an inspection window at the electronic board to check any malfunction without disassembling it.

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

191

AM

AZ

ON

IND

US

TRIA

L V

RF

CHANGEOVER BOXES MULTIGROUP

Available in versions of 2, 4 and 6 outputs, the y support a maximum of 45 kW of capacity and up to 24 indoor units depending on the model (see table in the AMAZON III PRO changeover boxes section). Each output can work in a different mode.

This indoor unit, only for the AMAZON III PRO 3 pipes range, is capable of producing domestic hot water. Temperature adjustment ranges from 20ºC to 45ºC and is based on the water outlet temperature.

SIMULTANEITY BETWEEN HEATING AND COOLING

Thanks to the changeover boxes, the system is capable of providing heating and cooling simultaneously, generating heat recovery in the system and therefore overall energy savings.

DOMESTIC HOT WATER

CHANGEROVER BOXES

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE

192

OUTDOOR UNITS - 3 PIPES

AMAZON III PRO

TECHNICAL SPECIFICATIONS

MODEL K3F-252 DN3S K3F-280 DN3S K3F-335 DN3S K3F-400 DN3S K3F-450 DN3S

Capacity HP 8 10 12 14 16

Cooling capacity kW 25.2 28 33.5 40 45

Cooling capacity Kcal/h 21,672 24,080 28,810 34,400 38,700

Cooling input kW 5.73 6.67 8.07 11.3 13.24

Heating capacity kW 27 32 38 45 50

Heating capacity Kcal/h 23220 27090 32250 38700 43000

Heating input kW 6.00 7.33 8.72 11.19 12.79

SEER 7.53 7.43 7.4 6.68 6.38

SCOP 6.23 6.05 6.02 5.67 5.45

Amount of connectable indoor units 13 16 20 23 26

Power supply V / F / Hz 380-415 / 3 / 50 380-415 / 3 / 50 380-415 / 3 / 50 380-415 / 3 / 50 380-415 / 3 / 50

Inverter compressor 1 1 1 2 2

Fans 2 2 2 2 2

Oil balance pipe diameter mm (Inch) Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4") Ø6.4 (1/4")

Liquid pipe diameter mm (Inch) Ø9.53 (3/8") Ø12.7 (1/2") Ø12.7 (1/2") Ø15.9 (5/8") Ø15.9 (5/8")

Gas high-pressure pipe diameter mm (Inch) Ø19.1 (3/4") Ø19.1 (3/4") Ø19.1 (3/4") Ø22.2 (7/8") Ø22.2 (7/8")

Gas low-pressure pipe diameter mm (Inch) Ø22.2 (7/8") Ø22.2 (7/8") Ø25.4 (1") Ø28.6 (1 1/8") Ø28.6 (1 1/8")

Gas balance high-pressure pipe diameter mm (Inch) Ø19.1 (3/4") Ø19.1 (3/4") Ø19.1 (3/4") Ø19.1 (3/4") Ø19.1 (3/4")

Refrigerant type R-410 A R-410 A R-410 A R-410 A R-410 A

Refrigerant factory charge gr 10000 10000 10000 13000 13000

Airflow m3/h 12000 12000 13000 15000 15000

Static Pressure Pa 40 40 40 40 40

Width/Height/Depth mm 1250/1615/765 1250/1615/765 1250/1615/765 1250/1615/765 1250/1615/765

Net weight Kg 255 255 255 303 303

Sound pressure dB (A) 57 57 58 60 60

Power cord (under 20 metres) mm2 (4+T)x2.5 (4+T)x4 (4+T)x6 (4+T)x10 (4+T)x16

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5 3x1.5 3x1.5

Cooling mode outdoor operation range Cº -5 to 48 -5 to 48 -5 to 48 -5 to 48 -5 to 48

Heating mode outdoor operation range Cº -20 to 24 -20 to 24 -20 to 24 -20 to 24 -20 to 24

BRANCH PIPES PRICE LIST

BRANCH PIPES - 3 PIPES BRANCH PIPES - 2 PIPES

OUTDOOR MODULES BRANCH PIPES

MODEL PRICE

KCMI 113 (KCMI100+KCMI200+KCMI200) £77

KCMI 213 (KCMI100+KCMI200+KCMI300) £102

KCMI 313 (KCMI200+KCMI300+KCMI300) £142

KCMI 413 (KCMI200+KCMI300+KCMI400) £163

KCMI 513 (KCMI300+KCMI400+KCMI500) £551

MODEL PRICE

KCMI 112 (KCMI100 + KCMI200) £46

MODEL PRICE

KCMER 32 £123

KCMER 33 £215

KCMER 34 £412

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

193

AM

AZ

ON

IND

US

TRIA

L V

RF

Direct-expansion system for 3 pipes aircooled designed for 25.2 kW to 180 kW cooling capacity units. Ideal for meeting the needs in medium and large industrial environments.

• High capacity Scroll DC Inverter compressors and ecological R410A refrigerant.

• Modular design with the option of combining the 5 individual modules (8-10-12-14 and 16 HP) up to 64 HP (4 modules maximum).

• Standard automatic redundancy between modules. It balances and extends the working life of the compressors of each module, whether of the Master unit or any of the Slaves.

• They allow for combinations containing up to 64 indoor units.

• It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.

• Fitted with a top air discharge system, this range is able to make air circulates through the condensation system thanks to the 40 Pa available pressure supplied by its DC Inverter fan.

• Cooling system with double liquid subcooling; the first system performs the subcooling process thanks to the delta-shaped heat exchanger and the second system carries out the subcooling process in each changeover box, thereby reaching up to 22.1 ºC and very high levels of energy efficiency.

• Up to 200 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).

GENERAL CHARACTERISTICS

FULL DC INVERTER

A NEW DESIGN WITH NOISE LEVELS REDUCTION THAT WHICH INCREASES AIRFLOW

INDOOR UNITS 64

DC

dB

INVERTER

PRICE LIST

MODEL PRICE

K3F-252 DN3S £6,281K3F-280 DN3S £6,651K3F-335 DN3S £7,643K3F-400 DN3S £8,624K3F-450 DN3S £9,045

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE

194

OUTDOOR UNITS - 3 PIPES

CHANGEOVER BOXES

Thanks to the changeover boxes, the system is capable of providing heating and cooling simultaneously, generating heat recovery in the system and therefore overall energy savings.

Available in versions of 2.4 and 6 outputs, they support a maximum of 45 kW of capacity and up to 24 indoor units depending on the model (for further information, please see attached table). Each output can work in a different mode.

CHANGEOVER BOXES MULTIGROUPPER OUTPUT PER BOX

MODELNUMBER OF

OUTPUTSMax UI Capacity

(KW)Max UI Capacity

(KW)Max UI Capacity

(KW)Max UI Capacity

(KW)

KVBM2 DN3 2 16 4 28 8

KVBM4 DN3 4 16 4 45 16

KVBM6 DN3 6 16 4 45 24

 

COOLING

HEATING

GENERAL CHARACTERISTICS

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

195

AM

AZ

ON

IND

US

TRIA

L V

RF

CHANGEOVER BOX

TECHNICAL SPECIFICATIONS

MODEL KVBM2 DN3 KVBM4 DN3 KVBM6 DN3

Cooling capacity kW Up to 28 Up to 45 Up to 45

Cooling capacity per output kW Up to 16 Up to 16 Up to 16

Max. amount of connectable indoor units 8 16 24

Maximum amount of indoor units per output 4 4 4

Width/Height/Depth mm 630/225/600 960/225/600 960/225/600

Net weight Kg 19.5 31 35

Liquid inlet pipe diameter mm (Inch) Ø12.7 (1/2") Ø15.9 (5/8") Ø15.9 (5/8")

Gas inlet high-pressure pipe diameter mm (Inch) Ø19.1 (3/4") Ø22.2 (7/8") Ø22.2 (7/8")

Gas inlet low-pressure pipe diameter mm (Inch) Ø25.4 (1") Ø31.8 (1 1/4") Ø31.8 (1 1/4")

Liquid pipe diameter per outlet mm (Inch) Ø9.53 (3/8") Ø9.53 (3/8") Ø9.53 (3/8")

Gas pipe diameter per outlet mm (Inch) Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8")

Shielded communication wires mm2 3x1.5 3x1.5 3x1.5

Power cord (under 20 metres) mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5

Power supply voltage V / F / Hz 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50

PRICE LIST

MODEL PRICE

KVBM2 DN3 £996

KVBM4 DN3 £1,514

KVBM6 DN3 £2,117

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE

196

SIZING OF PIPES

MINI AMAZON II / AMAZON UNITARIO SIDE AIR DISCHARGE 2 PIPES

HOW TO CHOOSE THE DISTRIBUTOR AND THE REFRIGERANT PIPELINE

CAPACITY OF UNITS HANGING FROM THE DISTRIBUTOR AND THE PIPE (X100 W)

PIPES DIMENSIONDRIFTERS

GAS LIQUID

<166 Ø15.9 (5/8") Ø9.5 (3/8") KCMI-100B-200B (KCMI 112)

166≤A<230 Ø19.1 (3/4") Ø9.5 (3/8") KCMI-100B-200B (KCMI 112)

230≤A<330 Ø22.2 (7/8") Ø9.5 (3/8") KCMI-100B-300B (KCMI 212)

330≤A Ø28.6 (1 1/8") Ø12.7 (1/2") KCMI-100B-300B (KCMI 212)

INDOOR UNITS TOTAL CAPACITYOF PIPE (X100 W)

LENGTH ≤10M LENGTH > 10M

LIQUID GAS LIQUID GAS

A≤45 Ø6.4(1/4") Ø12.7 (1/2") Ø9.5 (3/8") Ø15.9 (5/8")

56≤A≤160 Ø9.5 (3/8") Ø15.9 (5/8") Ø12.7 (1/2") Ø19.1 (3/4")

A≤200 Ø9.5 (3/8") Ø22.2 (7/8") Ø12.7 (1/2") Ø25.4 (1")

A≤ 250 Ø12.7 (1/2") Ø22.2 (7/8") Ø12.7 (1/2”) Ø22.2 (7/8”)

SIZING OF PIPES

1 Selection of the right pipe for indoor unit (pipes a-f)

2 Selection of distributors (A-E) and pipes (L2-L5)

DISTANCES AND HEIGHT DIFFERENCES

A - Capacity of indoor unit/units

A - Capacity of indoor unit/units

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

197

AM

AZ

ON

IND

US

TRIA

L V

RF

EQUIVALENT LENGTH OF LIQUID PIPE <45 EQUIVALENT LENGTH OF LIQUID PIPE ≥45

CAPACITY OF UNITS HANGING FROM THE

DISTRIBUTOR AND THE PIPE (X100 W)

GAS LIQUID DRIFTERS GAS LIQUID DRIFTERS

A<166 Ø15.9 (5/8") Ø9.5 (3/8")KCMI-100B-200B

(KCMI 112)Ø19.1 (3/4") Ø12.7 (1/2")

KCMI-100B-200B (KCMI 112)

166 ≤A <230 Ø19.1 (3/4") Ø9.5 (3/8")KCMI-100B-200B

(KCMI 112)Ø22.2 (7/8") Ø12.7 (1/2")

KCMI-100B-200B (KCMI 112)

230 ≤A <330 Ø22.2 (7/8") Ø9.5 (3/8")KCMI-100B-300B

(KCMI 212)Ø25.4 (1") Ø12.7 (1/2")

KCMI-100B-300B (KCMI 212)

330 ≤A <430 Ø22.2 (7/8") Ø12.7 (1/2")KCMI-100B-300B

(KCMI 212)Ø25.4 (1") Ø12.7 (1/2")

KCMI-100B-300B (KCMI 212)

430 ≤A <450 Ø25.4 (1") Ø12.7 (1/2”)KCMI-100B-300B

(KCMI 212)Ø28.6 (1 1/8") Ø12.7 (1/2")

KCMI-200B-300B (KCMI 312)

Important: Main pipe L1 can be selected from Table 2 or from Table 3, always trying to choose the most unfavourable option.

L1   A  

B  

L2  

a  

b  

L4  

N2  

N1  

C  L5  

D  c  

d  

e  

f  E  

L3  

N6  

N5  

N3  

N4  

3 Selection of main pipe (L1):

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE

198

SIZING OF PIPES

TOTAL CAPACITY OF UNITS HANGING FROM THE DISTRIBUTOR (X100 W)

PIPES DIMENSIONDRIFTERS

GAS LIQUID

A<166 Ø15.9 (5/8”) Ø9.5 (3/8") KCMI 100B-200B (KCMI 112)

166≤A<230 Ø19.1 (3/4”) Ø9.5 (3/8") KCMI 100B-200B (KCMI 112)

230≤A<330 Ø22.2 (7/8") Ø9.5 (3/8”) KCMI 100B-300B (KCMI 212)

330≤A<460 Ø28,6 (1 1/8") Ø12.7 (1/2") KCMI 100B-300B (KCMI 212)

460≤A<660 Ø28,6 (1 1/8") Ø15.9 (5/8") KCMI 200B-300B (KCMI 312)

660≤A<920 Ø34.9 (1 3/8") Ø19.1 (3/4") KCMI 200B-400B (KCMI 412)

920≤A<1350 Ø41.3 (1 5/8") Ø19.1 (3/4") KCMI 200B-400B (KCMI 412)

1350≤A<1800 Ø41.3 (1 5/8") Ø22.2 (7/8") KCMI 300B-500B (KCMI 512)

1800≤A Ø53.9 (2 1/8") Ø25.4 (1") KCMI 300B-500B (KCMI 512)

SET REFERENCE LIQUID GAS

KCMI 100B-200B (KCMI 112) E-100FRGB E-200FRGB

KCMI 100B-300B (KCMI 212) E-100FRGB E-300FRGB

KCMI 200B-300B (KCMI 312) E-200FRGB E-300FRGB

KCMI 200B-400B (KCMI 412) E-200FRGB E-400FRGB

KCMI 300B-500B (KCMI 512) E-300FRGB E-500FRGB

TOTAL CAPACITY OF INDOOR UNITS OF THE PIPE

(X100 W)

LENGTH ≤10M LENGTH > 10M

LIQUID GAS LIQUID GAS

≤45 Ø6.4 (1/4”) Ø12.7 (1/2”) Ø9.5 (3/8”) Ø15.9 (5/8”)

56≤A≤160 Ø9.5 (3/8”) Ø15.9 (5/8”) Ø12.7 (1/2”) Ø19.1 (3/4")

200 Ø9.5 (3/8”) Ø22.2 (7/8") Ø12.7 (1/2”) Ø25.4 (1")

250 Ø12.7 (1/2”) Ø22.2 (7/8") Ø12.7 (1/2”) Ø22.2 (7/8")

280 Ø12.7 (1/2”) Ø22.2 (7/8") Ø12.7 (1/2”) Ø22.2 (7/8")

400 Ø12.7 (1/2”) Ø28.6 (1 1/8”) Ø12.7 (1/2”) Ø22.2 (7/8")

450 Ø12.7 (1/2”) Ø28.6 (1 1/8”) Ø12.7 (1/2”) Ø22.2 (7/8")

560 Ø15.9 (5/8”) Ø28.6 (1 1/8”) Ø12.7 (1/2”) Ø22.2 (7/8")

AMAZON UNITARIO TOP AIR DISCHARGE / AMAZON III W / AMAZON IV PRO 2 PIPES

1 Selection of indoor unit pipe (pipes a-i)

Note: If the total capacity of indoor units exceeds the capacity of outdoor units, we will respect duct A from Table 3.

HOW TO CHOOSE THE DISTRIBUTOR AND THE REFRIGERANT PIPELINE

2 Selection of drifters (A - H) and pipes (L2-L8)

A - Capacity of indoor units

A - Capacity of indoor units

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

199

AM

AZ

ON

IND

US

TRIA

L V

RF

SAMPLE OF AMAZON IV PRO INSTALLATION WITH 3 OUTDOOR MODULES

TOTAL CAPACITY OF OUTDOOR

UNITS (HP)

LENGTH TOTAL EQUIVALENT OF LIQUID PIPE <90m LENGTH TOTAL EQUIVALENT OF LIQUID PIPE ≥90m

GAS LIQUID 1st DIstRIBUtOR (A) GAS LIQUID 1st DIstRIBUtOR (A)

8 Ø22.2 (7/8") Ø9.5 (3/8") KCMI 100B-300B (KCMI-212) Ø22.2 (7/8”) Ø12.7 (1/2") KCMI 100B-300B (KCMI-212)

10 Ø22.2 (7/8”) Ø9.5 (3/8") KCMI 100B-300B (KCMI-212) Ø25.4 (1") Ø12.7 (1/2") KCMI 100B-300B (KCMI-212)

12-14 Ø25.4 (1") Ø12.7 (1/2") KCMI 100B-300B (KCMI-212) Ø28.6 (1 1/8") Ø15.9 (5/8") KCMI 200B-300B (KCMI-312)

16 Ø28.6 (1 1/8") Ø12.7 (1/2”) KCMI 100B-300B (KCMI-212) Ø34.9 (1 3/8”) Ø15.9 (5/8") KCMI 200B-300B (KCMI-312)

18-22 Ø28.6 (1 1/8”) Ø15.9 (5/8") KCMI 200B-300B (KCMI-312) Ø34.9 (1 3/8”) Ø19.1 (3/4") KCMI 200B-400B (KCMI-412)

24 Ø28.6 (1 1/8”) Ø15.9 (5/8") KCMI 200B-300B (KCMI-312) Ø34.9 (1 3/8”) Ø19.1 (3/4") KCMI 200B-400B (KCMI-412)

26-32 Ø34.9 (1 3/8”) Ø19.1 (3/4") KCMI 200B-300B (KCMI-312) Ø41.3 (1 5/8”) Ø22.2 (7/8") KCMI 300B-500B (KCMI-512)

36-48 Ø41.3 (1 5/8”) Ø19.1 (3/4") KCMI 200B-400B (KCMI-412) Ø41.3 (1 5/8") Ø22.2 (7/8") KCMI 300B-500B (KCMI-512)

50-64 Ø41.3 (1 5/8”) Ø22.2 (7/8") KCMI 300B-500B (KCMI-512) Ø53.9 (2 1/8”) Ø25.4 (1") KCMI 300B-500B (KCMI-512)

66-88 Ø53.9 (2 1/8”) Ø25.4 (1") KCMI 300B-500B (KCMI-512) Ø53.9 (2 1/8”) Ø25.4 (1") KCMI 300B-500B (KCMI-512)

4 Selection of drifters (L,M,N) and pipes (g1, g2, g3, g4, G1, G2) of outdoor unit. Use the next table if several modules are connected:

*Includes: gas distributor, liquid distributor and oil balance distributor.

ModuleOutd. unit

ModuleOutd. unit

ModuleOutd. unit

A

L1 A L2 B C D E F G HL3 L4 L5 L6 L7 L8

b c d e f g h i

MODULES NO DRAWING PIPE DIAMETER MODULES CONNECTION KIT*

2g1, g2:8-12 HP: 25.4 Ø / 12.7 Ø;14-22 HP: 31.8 Ø / 15.9 Ø

L :KIT KCME 12

3

g1, g2, g3:8-12 HP: 25.4 Ø / 12.7;14-22 HP: 31.8 Ø / 15.9 Ø;G1: 38.1 Ø / 19.1 Ø

L + M:KIT KCME 13

4

g1, g2, g3, g4:8-12 HP: 25.4 Ø / 12.7;14-22 HP: 31.8 Ø / 15.9 Ø;G1: 38.1 Ø / 19.1 ØG2: 41.3 Ø / 22.2 Ø

L + M+ N:KIT KCME 14

3 Selection of main pipe (L1):

Gas and liquid module pipe

Modules joint pipe Main pipe Oil balance pipe

Modules connection kit

L

L

L

M

M

N

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE

200

SIZING OF PIPES

AMAZON III PRO 3 PIPES

OUTDOOR UNITS TOTAL CAPACITY (HP)

PIPES DIMENSION

KW LOW-PRESSURE GAS HIGH-PRESSURE GAS LIQUID DRIFTERS

A < 56 Ø12.7 (1/2") Ø6.35 ( 1/4”) KCMI 100B-200B-200B (KCMI-113)

56 ≤ A < 166 Ø19.1 (3/4") Ø15.9 (5/8") Ø9.53 (3/8”) KCMI 100B-200B-200B (KCMI-113)

166 ≤ A < 230 Ø22.2 (7/8") Ø19.1 (3/4") Ø9.53 (3/8”) KCMI 100B-300B-200B (KCMI-213)

230 ≤ A < 330 Ø22.2 (7/8") Ø19.1 (3/4") Ø12.7 (1/2”) KCMI 100B-300B-200B (KCMI-213)

330 ≤ A < 460 Ø28.6 (1 1/8") Ø22.2 (7/8") Ø12.7 (1/2”) KCMI 200B-300B-300B (KCMI-313)

460 ≤ A < 660 Ø28.6 (1 1/8") Ø22.2 (7/8") Ø15.9 (5/8 ”) KCMI 200B-300B-300B (KCMI-313)

660 ≤ A < 920 Ø34.9 (1 3/8") Ø28.6 (1 1/8") Ø 19.1 (3/4”) KCMI 200B-400B-300B (KCMI-413)

920 ≤ A < 1350 Ø41.3 (1 5/8") Ø34.9 (1 3/8") Ø 19.1 (3/4”) KCMI 300B-400B-500B (KCMI-513)

1350 ≤ A Ø53.9 (2 1/8") Ø41/3 (1 5/8") Ø22.2 (7/8”) KCMI 300B-400B-500B (KCMI-513)

2 Selection of main pipe (L1)

OUTDOOR UNITS TOTAL

CAPACITY (HP)

LENGTH TOTAL EQUIVALENT OF PIPES <90m LENGTH TOTAL EQUIVALENT OF PIPES ≥90m

LOW-PRESSURE GAS

HIGH-PRESSURE GAS

LIQUID 1st DISTRIBUTOR (A)LOW-

PRESSURE GAS

HIGH-PRESSURE

GASLIQUID 1st DIstRIBUtOR (A)

8 Ø22.2 (7/8") Ø19.1 (3/4") Ø3/8 (9.53) KCMI 100B-300B-200B (KCMI-213) Ø22.2 (7/8") Ø19.1 (3/4") Ø12.7 (1/2") KCMI 100B-300B-200B (KCMI-213)

10 Ø22.2 (7/8") Ø19.1 (3/4") Ø12.7 (1/2") KCMI 100B-300B-200B (KCMI-213) Ø22.2 (7/8") Ø19.1 (3/4") Ø12.7 (1/2") KCMI 100B-300B-200B (KCMI-213)

12 Ø25.4 (1") Ø19.1 (3/4") Ø12.7 (1/2") KCMI 200B-300B-300B (KCMI-313) Ø25.4 (1") Ø19.1 (3/4") Ø15.9 (5/8") KCMI 200B-300B-300B (KCMI-313)

14-16 Ø28.6 (1 1/8") Ø22.2 (7/8") Ø15.9 (5/8") KCMI 200B-300B-300B (KCMI-313) Ø28.6 (1 1/8") Ø22.2 (7/8") Ø15.9 (5/8") KCMI 200B-300B-300B (KCMI-313)

18-22 Ø34.9 (1 3/8”) Ø28.6 (1 1/8") Ø15.9 (5/8") KCMI 200B-300B-300B (KCMI-313) Ø31.8 (1 1/4") Ø28.6 (1 1/8") Ø19.1 (3/4") KCMI 200B-300B-300B (KCMI-313)

24 Ø34.9 (1 3/8") Ø28.6 (1 1/8") Ø15.9 (5/8") KCMI 200B-400B-300B (KCMI-413) Ø34.9 (1 3/8") Ø28.6 (1 1/8") Ø19.1 (3/4") KCMI 200B-400B-300B (KCMI-413)

26-32 Ø34.9 (1 3/8") Ø28.6 (1 1/8") Ø19.1 (3/4") KCMI 200B-400B-300B (KCMI-413) Ø34.9 (1 3/8") Ø28.6 (1 1/8") Ø22.2 (7/8") KCMI 200B-400B-300B (KCMI-413)

34-48 Ø41.3 (1 5/8") Ø34.9 (1 3/8") Ø19.1 (3/4") KCMI 300B-400B-500B (KCMI-513) Ø41.3 (1 5/8") Ø34.9 (1 3/8") Ø22.2 (7/8") KCMI 300B-400B-500B (KCMI-513)

50-64 Ø53.9 (2 1/8") Ø41.3 (1 5/8") Ø22.2 (7/8") KCMI 300B-400B-500B (KCMI-513) Ø44.5 (1 3/4") Ø38.1 (1 1/2") Ø25.4 (1") KCMI 300B-400B-500B (KCMI-513)

HOW TO CHOOSE THE DISTRIBUTOR AND THE REFRIGERANT PIPELINE

1 Selection of main pipe (L1 - L11):

SET REFERENCE LIQUID HIGH-PRESSURE GAS LOW-PRESSURE GAS

2 pipes KCMI 100B-200B (KCMI-112) E-100FRGb - E-200FRGb

3 pipes

KCMI 100B-200B-200B (KCMI-113) E-100FRGb E-200FRGb E-200FRGb

KCMI 100B-300B-200B (KCMI-213) E-100FRGb E-200FRGb E-300FRGb

KCMI 200B-300B-300B (KCMI-313) E-200FRGb E-300FRGb E-300FRGb

KCMI 200B-400B-300B (KCMI-413) E-200FRGb E-300FRGb E-400FRGb

KCMI 300B-400B-500B (KCMI-513) E-300FRGb E-400FRGb E-500FRGb

MODULES NO DRAWING

2

3

4

CONNECTION HIGH-PRESSURE GAS LOW-PRESSURE GAS LIQUID

g1,g2,g3,g48/10/12HP Ø7/8(22.2) Ø3/4(19.1) Ø1/2(12.7)

14/16HP Ø1-1/8(28.6) Ø7/8(22.2) Ø5/8(15.9)

G1 Ø1-3/8(34.9) Ø1-1/8(28.6) Ø3/4(19.1)

G2 Ø1-5/8(41.3) Ø1-3/8(34.9) Ø7/8(22.2)

Important: Main pipe L1 can be selected from Table 1 or from Table 2, always trying to choose the most unfavourable option.

Includes: Low-pressure gas distributor, high-pressure gas distributor, liquid distributor and oil balance distributor and high-pressure gas balance distributor.

3 Selection of outdoor unit's pipe (g1, g2, g3, g4, G1, G2)

When there is more than one module connected, please use the following table:

Design and Install for you

201

AM

AZ

ON

IND

US

TRIA

L V

RF

A - Indoor units capacity

5 Selection of the 2-DUCTS main pipe and 2-DUCTS distributor (a, g, j, k)

6 Selection of indoor unit's pipe to be connected to the distributor or the KVB (b, c, d, e, f, h, i, l, m, n)

7 Selection of KVB’s multigroup

INDOOR UNIT TOTAL CAPACITY GAS PIPE LIQUID DISTRIBUTOR

A<166 Ø15.9 (5/8”) Ø9.53 (3/8”) KCMI 100B-200B (KCMI-112)

INDOOR UNIT CAPACITYSELECTION OF INDOOR UNIT'S PIPE TO B

CONNECTED TO THE DISTRIBUTOR OR TO THE KVB (KVB≤10M)

SELECTION OF INDOOR UNIT'S PIPE TO B CONNECTED TO THE DISTRIBUTOR OR TO THE KVB

(KVB>10M)

KW GAS PIPE LIQUID GAS PIPE LIQUID

A<56 Ø12.7 (1/2”) Ø6.35 (1/4”) Ø15.9 (5/8”) Ø9.53 (3/8”)

56≤A≤166 Ø15.9 (5/8”) Ø9.53 (3/8”) Ø19.1 (3/4”) Ø12.7 (1/2”)

200 Ø9.5 (3/8”) Ø22.2 (7/8") Ø12.7 (1/2”) Ø25.4 (1")

250 Ø12.7 (1/2”) Ø22.2 (7/8")

280 Ø12.7 (1/2”) Ø22.2 (7/8")

400 Ø12.7 (1/2”) Ø28.6 (1 1/8”)

450 Ø12.7 (1/2”) Ø28.6 (1 1/8”)

560 Ø15.9 (5/8") Ø28.6 (1 1/8")

4 Selection of the modules connection kit (L, M, N)

OUTDOOR MODULES NO CONNECTED TO COOLING DISTRIBUTORS

2 units L:KIT KCMER 32

3 units L+M:KIT KCMER 33

4 units L+M+N:KIT KCMER 34

Modules T-Type distributor g1, g2, g3, G1

MODEL NO

EACH GROUP EACH KVB

CAPACITY QUANTITY CAPACITY QUANTITY

Max. IU Max. IU Max. IU Max. IU

KVBM2 DN3 16kw

4

28kw 8

KVBM4 DN3 16kw 45kw 16

KVBM6 DN3 16kw 45kw 24

PIPE TYPE CODE

Main pipe L13-DUCTS pipe L2-L112-DUCTS pipe a, b, ….n

3-DUCTS distributor A,B,C,D,E2-DUCTS distributor I,II,III,IV

Modules connecting distrib. L,MModules T-Type pipe g1,g2,g3, G1KVB inverter boxes KVB1, …KVB6

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE

202

SIZING OF PIPES

DISTANCES AND HEIGHT DIFFERENCES 2 PIPES

AMAZON IV PRO ALL MODULES

PIPING LENGTH

Total length from outdoor unit to all the indoor units. ≤ 1000m

Length between the outdoor unit and the furthest indoor unit.

Real ≤ 175m

Equivalent ≤ 200m

Length between the first distributor and the furthest indoor unit. ≤ 40 (90m*)

Length between one indoor unit and the closest distributor -

HEIGHT DIFFERENCE

Level difference between outdoor

unit and indoor unit

The outdoor unit is higher

than the indoor unit ≤ 110m

The outdoor unit is lower

than the indoor unit ≤90m

Level difference between indoor units ≤ 30m

MINI AMAZON II 8/10,5 KW 12/14/16/18KW

PIPING LENGTH

Total length from outdoor unit to all the indoor units. ≤100m

Length between the outdoor unit and the furthest indoor unit.

Real ≤45m ≤60m

Equivalent ≤50m ≤70m

Length between the first distributor and the furthest indoor unit. ≤20 (40m*)

Length between one indoor unit and the closest distributor 15m

HEIGHT DIFFERENCE

Level difference between outdoor unit

and indoor unit

The outdoor unit is higher

than the indoor unit ≤30m

The outdoor unit is lower

than the indoor unit ≤20m

Level difference between indoor units ≤8m

AMAZON III W 8/10/12 HP

PIPING LENGTH

Total length from outdoor unit to all the indoor units. ≤300m

Length between the outdoor unit and the furthest indoor unit.

Real ≤120m

Equivalent ≤150m

Length between the first distributor and the furthest indoor unit. ≤40 (90 m*)

Length between one indoor unit and the closest distributor -

HEIGHT DIFFERENCE

Level difference between outdoor

unit and indoor unit

The outdoor unit is higher

than the indoor unit ≤50m

The outdoor unit is lower

than the indoor unit ≤40m

Level difference between indoor units ≤30m

*Check for lengths between 20 and 40 metres.

*Check for lengths between 40 and 90 metres.

*Check for lengths between 40 and 90 metres.

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

203

AM

AZ

ON

IND

US

TRIA

L V

RF

OUTDOOR UNIT

INDOOR UNITS

AMAZON III W

30 m

40m (90m)

110m

200 m

OUTDOOR UNIT

INDOOR UNITS

MINI AMAZON II

8 m

20m (40m)

30m

50m (70m)

OUTDOOR UNIT

INDOOR UNITS

AMAZON III W

30 m

40m (90m)

50m

150 m

AMAZON III W

AMAZON IV PRO

MINI AMAZON II

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE

204

SIZING OF PIPES

DISTANCES AND HEIGHT DIFFERENCES 2 PIPES

AMAZON UNITARIO TOP AIR DISCHARGE 10-16 HP 20/22/24 HP

PIPING LENGTH

Total length from outdoor unit to all the indoor units. ≤350m ≤1000m

Length between the outdoor unit and the furthest indoor unit.

Real ≤150m ≤175m

Equivalent ≤175m ≤200m

Length between the first distributor and the furthest indoor unit. ≤40 ≤40 (90m*)

Length between one indoor unit and the closest distributor ≤15 ≤15

HEIGHT DIFFERENCE

Level difference between outdoor unit

and indoor unit

The outdoor unit is higher

than the indoor unit ≤70m ≤110m

The outdoor unit is lower

than the indoor unit ≤50m ≤70m

Level difference between indoor units ≤15m ≤30m

AMAZON UNITARIO SIDE AIR DISCHARGE 20/22/24 KW 40/45 KW

PIPING LENGTH

Total length from outdoor unit to all the indoor units. ≤120m ≤250m

Length between the outdoor unit and the furthest indoor unit.

Real ≤60m ≤100m

Equivalent ≤70m ≤120m

Length between the first distributor and the furthest indoor unit. ≤20m ≤40 m

Length between one indoor unit and the closest distributor ≤15m ≤15m

HEIGHT DIFFERENCE

Level difference between outdoor unit

and indoor unit

The outdoor unit is higher

than the indoor unit ≤30m ≤30m

The outdoor unit is lower

than the indoor unit ≤20m ≤20m

Level difference between indoor units ≤8m ≤8m

*Check for lengths between 40 and 90 metres.

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

205

AM

AZ

ON

IND

US

TRIA

L V

RF

OUTDOOR UNITS

INDOOR UNITS

AMAZON III W

30 m

40m (90m)

50m

150 m

OUTDOOR UNIT

INDOOR UNITS

MINI AMAZON II

8 m

20m (40m)

30m

70m (120m)

AMAZON UNITARIO SIDE AIR DISCHARGE

AMAZON UNITARIO TOP AIR DISCHARGE

Go back to General Contents Go back to AMAZON Index(Index)

INDUSTRIAL VRF RANGE

206

SIZING OF PIPES

AMAZON III PRO 3-PIPES

AMAZON III PRO ALL MODULES

PIPING LENGTH

Total length from outdoor unit to all the indoor units. ≤1000 m

Length between the outdoor unit and the furthest indoor unit.

Real ≤175 m

Equivalent ≤200 m

Length between the first distributor and the furthest indoor unit.

≤40m (90 m)

HEIGHT DIFFERENCE

Level difference between outdoor unit

and indoor unit

The outdoor unit

is higher than the

indoor unit

≤110m

The outdoor unit

is lower than the

indoor unit

≤ 70 m

Level difference between indoor units ≤ 30 m

*Length between the KVB box and the furthest indoor unit. 40 m.

*Check for lengths between 40 and 90 metres.

DISTANCES AND HEIGHT DIFFERENCES 3 PIPES

Go back to General Contents Go back to AMAZON Index(Index)

Design and Install for you

207

AM

AZ

ON

IND

US

TRIA

L V

RF

AMAZON III PRO

OUTDOOR UNIT

INDOOR UNITS

30 m

40m (90m)

110m

200 m

Go back to General Contents Go back to AMAZON Index(Index)

CONTROLSCONTROL SYSTEM RANGE

209

Design and Install for you

INTRODUCTION TO THE PRODUCT RANGE ......................................210

UNITS

INDIVIDUAL WIRELESS AND WIRED CONTROLLERS ................212

CENTRALISED........................................................................... .....214

BMS & SOFTWARE ........................................................................216

ACCESSORIES ................................................................................224

CONTROLSCONTROL SYSTEM RANGE

CONTROLSCONTROL SYSTEM RANGE

210

CONTROL SYSTEMSRANGE

INTRODUCTION TO THE RANGE OF PRODUCTS

Introducing the 2017 KAYSUN UK controllers' range, where we would like to highlight our cutting-edge wireless controllers and their enhanced functions, such as a built-in ambient sensor, a self-cleaning function and the remote control lock button, among others. Among all these controllers, the most outstanding are the KID-02 S, included in SUITE and ZEN units. This wireless controller is able to interact with some of the models in order to provide working parameters, which could be partly modified without accessing the electronic board of the unit. In wired controllers, the most outstanding is the KC-03 SPS, a bidirectional controller with a renewed appearance, communication through just 2 non-polarised wires and fitted with the best features, such as alarm codes and a weekly timer.

Furthermore, KAYSUN UK offers a complete range of interfaces for BMS Lonworks, Bacnet, Modbus and KNX, as well as a gateway KAYSUN-Airzone or the Kaynet control, a software for managing KAYSUN UK cooling systems by computer. Finally, we would like to introduce the KCC-64 WEB controller, a device that allows the remote control of 64 indoor units through the Internet by Smartphone, Tablet or PC.

Always at the forefront regarding aesthetics and functionality, the KC-03 SPS can control up to 16 indoor units as a group with only two communication wires. It is fitted with a weekly timer and includes the Follow me function, which helps control the start/stop function of the unit from the controller's sensor. It is compatible with most units of the SUITE and ZEN range.

In 2016, KAYSUN UK unveiled its K03 USB WiFi control device for the wall-mounted units of the SUITE range: In 2017, KAYSUN UK will unveil its new adaptor for units in the ZEN range. These accessories connect the unit to our domestic WiFi network and control it through an App installed on our smartphone. The application also includes a weekly timer built into the App to ease and improve the control function of our air-conditioning system.

For the SUITE and ZEN ranges. Among the features of this new control, we would like to emphasise its capability to read operating data on most units, such as the room temperature, pipeline temperature, discharge temperature, the compressor's energy consumption, and so on. Moreover, it allows the user to change the operating parameters of said units and to activate the Auto Restart function, change the compensation temperature, configure the fan to stop, etc. All these features allow the installation engineer to adapt the unit more easily to the spaces to be climate controlled, and makes it easier to control the operation of the unit during service tasks. We would like also to stress that this new control is fitted with the corresponding keys to activate/deactivate the following options: SILENCE, 8º HEATING, FOLLOW ME and AUTO-CLEANNING modes, provided that the indoor unit is compatible with it.

CONTROL SYSTEMS RANGE CONTROLS

KC-03 SPSWIFI ADAPTORS

KID-02 S

"COMPREHENSIVE SOLUTIONS AT YOUR

FINGERTIPS"

NEW

Go back to General Contents Go back to CONTROLS Index(Index)

211

Design and Install for you

CON

TR

OLS

CON

TRO

L S

YS

TEM

S

AMAZON

AMAZON

AMAZON

AMAZON

AMAZON

ZEN

ZEN

ZEN

ZEN

ZEN

SUITE

SUITE

SUITE

SUITE

SUITE

KI-02.3 S

KID-02 S

KC-01 S

KC-02.1 H

KC-03 SPS

KCT-02.1 SR

KMC-32 E

KCC-16

KCC-64 WEB

K01-LON

K01-WATT

INTERFACEXYE ON

INDIVIDUAL WIRELESS

ACCESSORIES

INDIVIDUAL WIRED

CENTRALISED

BMS AND SOFTWARE

COMPATIBILITY PRODIGY 1X1

PRODIGY 1X1

PRODIGY 1X1

PRODIGY 1X1

PRODIGY 1X1

AUREA II 1X1

AUREA II 1X1

AUREA II 1X1

AUREA II 1X1

AUREA II 1X1

ONNIX 1X1

ONNIX 1X1

ONNIX 1X1

ONNIX 1X1

ONNIX 1X1

MULTI

MULTI

MULTI

MULTI

MULTI

KSD 1X1

KSD 1X1

KSD 1X1

KSD 1X1

KSD 1X1COMPATIBILITY

COMPATIBILITY

COMPATIBILITY

COMPATIBILITY

OUR RANGE OF PRODUCTS

KCC-64 I-PS

KCCT-64 I

K03-MODBUS

K02-MODBUS

K01-BACNET

KAHU

KAYNET CONTROL

K01-KNX

K01-WIFI

NEW

Except for Cassette 840x840

Except for Cassette 840x840

Except for Cassette 840x840

Except for Aurea II, Onnix and KCIS 840x840

Except for Aurea II, Onnix and KCIS 840x840

Except for Aurea II, Onnix and KCIS 840x840

Ducts and cassette type only

Ducts and cassette type only

Except for wall-mounted units

Except for wall-mounted units

Except for wall-mounted units

Except for wall-mounted units

Except for wall-mounted units

Except for wall-mounted units

Except for wall-mounted units

Except for wall-mounted units

Except for wall-mounted units

Only KSD

Except for MINI AMAZON II

Except MINI AMAZON II and AMAZON III PRO

3 ducts

Go back to General Contents Go back to CONTROLS Index(Index)

212

CONTROL SYSTEMSRANGE

INDIVIDUAL WIRELESS AND WIRED

CONTROLLERS

• Wireless controller.• FOLLOW ME.• LED function.• Turbo function.• Silence function.• Night mode.• 8 ºC function.• Self-cleaning function.• Units operating parameters query.• Units operating parameters change. • Mute function.

KID-02 S

INDIVIDUAL WIRELESS AND WIRED

GENERAL CHARACTERISTICS

KI-02.3 S

• Wireless controller.• FOLLOW ME.• 26ºC function.• AMAZON indoor units addressing.• AUTO mode activation/deactivation.

GENERAL CHARACTERISTICS

KC-01 S

• Wired controller.• FOLLOW ME.

GENERAL CHARACTERISTICS

PRICE LIST

MODEL COMPATIBLE WITH PRICE

KID-02 S SUITE - ZEN £16

Check available functions for each unit.

Standard in Prodigy, Onnix and Aurea II ranges.

PRICE LIST

MODEL COMPATIBLE WITH PRICE

KI-02.3 S AMAZON £22

PRICE LIST

MODEL COMPATIBLE WITH PRICE

KC-01 SSUITE*

ZEN**

AMAZON

£38

* Except for Aurea II, Onnix and Cassette 840x840

** Except Cassette 840x840

Go back to General Contents Go back to CONTROLS Index(Index)

213

Design and Install for you

CON

TR

OLS

CON

TRO

L S

YS

TEM

S

KC-03 SPS

• Wired controller with 2 non-polarised wires.

• FOLLOW ME.• Malfunction codes display.• Weekly timer.• Capacity to control up to

16 indoor units.• Bidirectional.

GENERAL CHARACTERISTICS

KC-02.1 H

• Wired controller.• Hotel-type simplified controller

with Operation mode function hidden.

• 26ºC function.• Memory function.

HOTEL SPECIAL

GENERAL CHARACTERISTICS

KCT-02.1 SR

• Wired controller. • FOLLOW ME.• Touch control.• AMAZON indoor units addressing.• Filter cleaning alarm.• Built-in infrared signal receiver.• Memory function.

GENERAL CHARACTERISTICS

PRICE LIST

MODEL COMPATIBLE WITH PRICE

KC-03 SPSSUITE*

ZEN£43

* Except for wall-mounted and KSD models

PRICE LIST

MODEL COMPATIBLE WITH PRICE

KC-02.1 HSUITE*

ZEN**

AMAZON

£46

PRICE LIST

MODEL COMPATIBLE WITH PRICE

KCT-02.1 SRSUITE*

ZEN**

AMAZON

£58

* Except for Aurea II, Onnix and Cassette 840x840

** Except Cassette 840x840

* Except for Aurea II, Onnix and Cassette 840x840

** Except Cassette 840x840

OPTIONALMOTORIZED PANEL

COMPATIBLE WITH

Go back to General Contents Go back to CONTROLS Index(Index)

214

CONTROL SYSTEMSRANGE

CENTRALISED

KCCT-64 I

• Touch control.• Indoor centralised controller.• Up to 64 indoor units• Emergency stop.

KMC-32 E

• Centralised display for outdoors.• Up to 32 modules.• If outdoor unit is fitted with the K01-WATT

wattmeter, total consumption of each module is displayed.

KCC-64 I-PS

• Indoor centralised controller.• Up to 64 indoor units.• Emergency stop.• Weekly timer.• Non-compatible with superior controls.

CENTRALISED

GENERAL CHARACTERISTICS

GENERAL CHARACTERISTICS

GENERAL CHARACTERISTICS

PRICE LIST

MODEL COMPATIBLE WITH PRICE

KCCT-64 ISUITE*

ZEN

AMAZON

£308

PRICE LIST

MODEL COMPATIBLE WITH PRICE

KMC-32 E AMAZON £154

PRICE LIST

MODEL COMPATIBLE WITH PRICE

KCC-64 I-PSSUITE*

ZEN

AMAZON

£246

*except wall-mounted units

*except wall-mounted units

Go back to General Contents Go back to CONTROLS Index(Index)

215

Design and Install for you

CON

TR

OLS

CON

TRO

L S

YS

TEM

S

KCC-16

KCC-64 WEB

• Indoor centralised controller.• Up to 16 indoor units.• On/Off for individual units and Operating

mode change.• Non-compatible with superior controls.• Compatible with other centralised controls.

• Units control through WEB or Smartphone APP.• Indoor centralised controller.• Up to 64 indoor units.• Weekly timer.• Non-compatible with superior controls.

GENERAL CHARACTERISTICS

GENERAL CHARACTERISTICS

PRICE LIST

MODEL COMPATIBLE WITH PRICE

KCC-16SUITE*

ZEN

AMAZON

£92

PRICE LIST

MODEL COMPATIBLE WITH PRICE

KCC-64 WEBSUITE*

ZEN

AMAZON

£616

*except wall-mounted units

*except wall-mounted units

Go back to General Contents Go back to CONTROLS Index(Index)

216

BMS AND SOFTWARECONTROL SYSTEMS

RANGE

K01-LON

• BMS interface, direct gateway to Lonworks.• Centralised controllers not required.• Up to 64 combinable indoor units.

K01-LON

UP TO 64 INDOOR UNITS

SYSTEM 1

SYSTEM 2

X,Y,E P,Q,E

P,Q,E

P,Q,ESYSTEM NLONWORKSBMS

BMS AND SOFTWARE

INSTALLATION EXAMPLE

GENERAL CHARACTERISTICS

PRICE LIST

MODEL COMPATIBLE WITH PRICE

K01-LONSUITE*

ZEN

AMAZON

£2,464

*except wall-mounted units

Go back to General Contents Go back to CONTROLS Index(Index)

217

Design and Install for you

CON

TR

OLS

CON

TRO

L S

YS

TEM

S

K02-MODBUS

K03-MODBUS

• BMS interface, direct gateway to MODBUS through RTU and TCP/IP.• Up to 64 indoor units and 4 outdoor units of the same cooling system.• Centralised controllers not required.

• BMS interface, direct gateway to MODBUS RTU (RS-485). • Connection to HA and HB.• Direct connection to the indoor unit.• One interface per unit (MODBUS 1x1).

INSTALLATION EXAMPLE

GENERAL CHARACTERISTICS

GENERAL CHARACTERISTICS

OUTDOOR UNITS

UP TO 64 INDOOR UNITS

HASTA 4 UNIDADES EXTERIORES

K02-MODBUS

P,Q,E

K1,K2,E

K1,K2,E

X,Y,E

MODBUSBMS

UP TO 4 OUTDOOR UNITS OF THE SAME COOLING SYSTEM

RTU (RS-485) HA,HB

INSTALLATION EXAMPLE

PRICE LIST

MODEL COMPATIBLE WITH PRICE

KO2-MODBUSSUITE*

ZEN

AMAZON

£2,464

PRICE LIST

MODEL COMPATIBLE WITH PRICE

K03-MODBUSSUITE*

ZEN

Price on application

*except wall-mounted units

*Except for wall-mounted and KSD models

Go back to General Contents Go back to CONTROLS Index(Index)

218

BMS AND SOFTWARECONTROL SYSTEMS

RANGE

K01-BACNET

• Direct BMS interface to BACNET.• 4 ports available for indoor and outdoor units. • Up to 256 indoor units.• Up to 128 outdoor units.

HUB

XYE

XYE

CON IP MONITORED SYSTEM BACNET IP PROTOCOLBMS

OUTDOOR UNITS

OUTDOOR UNITS

K01-BACNET

K1,K2,E P,Q,E

P,Q,E

INDOOR UNITS

INDOOR UNITS

BMS AND SOFTWARE

INSTALLATION EXAMPLE

GENERAL CHARACTERISTICS

PRICE LIST

MODEL COMPATIBLE WITH PRICE

K01-BACNETSUITE*

ZEN

AMAZON

£2,464

*except wall-mounted units

Go back to General Contents Go back to CONTROLS Index(Index)

219

Design and Install for you

CON

TR

OLS

CON

TRO

L S

YS

TEM

S

K01-KNX

• BMS interface, direct gateway to KNX.• Centralised controllers not required.• Three interface types, 1, 16 or 64 indoor units.

INSTALLATION EXAMPLE

GENERAL CHARACTERISTICS

KNX CONTROL SYSTEM

INDOOR UNITS

P.Q.E P.Q.E

XYE XYE XYE

KO1-KNX 1 KO1-KNX 1 KO1-KNX 1

P.Q.E

OUTDOOR UNIT

PRICE LIST

MODEL COMPATIBLE WITH PRICE

KO1-KNX 1SUITE*

ZEN

AMAZON

£252

KO1-KNX 16 £1,694

KO1-KNX 64 £3,264

*except wall-mounted units

Go back to General Contents Go back to CONTROLS Index(Index)

220

BMS AND SOFTWARECONTROL SYSTEMS

RANGE

K01-WIFI

• The user connects via a web page or APP for IOS or Android and controls the air-conditioning units in an easy and intuitive way. A cloud server manages the whole process.

• Centralised controllers not required.• Designed for controlling just one unit• Collaboration agreement with Intesis Home.

INSTALLATION EXAMPLE

BMS AND SOFTWARE

THE COMMAND IS SENT FROM OUR DEVICE

1 2

1

2

K01-WIFI device

External antenna

+

INFORMATION IS TRANSFERRED THROUGH THE CLOUD SERVER

A CONVENTIONAL ROUTER RECEIVES THE COMMAND

IT SENDS THE SIGNAL TO OUR UNITSTHE INDOOR UNIT RUNS THE COMMAND

1 2

3 4

*INFRARED DEVICE

GENERAL CHARACTERISTICS

SMARTPHONE PC TABLET

PRICE LIST

MODEL COMPATIBLE WITH PRICE

K01-WIFISUITE

ZEN

AMAZON

£178

Go back to General Contents Go back to CONTROLS Index(Index)

221

Design and Install for you

CON

TR

OLS

CON

TRO

L S

YS

TEM

S

¿HOW DOES IT WORK?

WHAT DO YOU NEED?

DOES IT TAKE UP SPACE ON MY MOBILE DEVICE?

TURN YOUR EQUIPMENT ON AND OFF+CHANGE THE FUNCTION (HEAT, COOL, DRY...)+CONTROL THE POSITION OF THE LOUVRES+DISPLAY THE TEMPERATURE IN YOUR HOUSE +

Control all the Air Conditioning units via the Internet from a website or from an application for your Smartphone or Tablet.

• Switch on the Air Conditioning before arriving home.

• Change the automatic switch on programme if you are going to arrive later.

• Know the temperature in the rooms of your house at all times.

You only need to install a small device into your air-conditioning unit to begin remotely controlling your units. The WIFI router at your place will send your commands.

No! All the information necessary for the operation of the new K01-WIFI control is stored in the cloud during the process.

REMOTE CONTROLLEROF YOUR

AIR CONDITIONER

ADVANTAGES

K01-WIFI

SMARTPHONE PC TABLET

INSTANT CONTROL ANYWHERE

OPERATION INTERFACE EXAMPLE

Go back to General Contents Go back to CONTROLS Index(Index)

222

BMS AND SOFTWARECONTROL SYSTEMS

RANGE

• A KAYSUN solution for a comprehensive control of your units.• Up to 16 cooling circuits.• Up to 256 indoor units.• Up to 64 outdoor units.• Centralised controllers not required.• Simple Web control though IP or software.• Network control software included.

KAYNET CONTROL

BMS AND SOFTWARE

GENERAL CHARACTERISTICS

INSTALLATION EXAMPLE

PRICE LIST

MODEL COMPATIBLE WITH PRICE

KAYNET CONTROL

SUITE*

AMAZON

ZEN

£3,696

*except wall-mounted units

Go back to General Contents Go back to CONTROLS Index(Index)

223

Design and Install for you

CON

TR

OLS

CON

TRO

L S

YS

TEM

S

BUILDING LAYOUT CONSUMPTION CONTROL AND RECORD

MAIN DISPLAY SCHEDULE

GROUPS LIMITATION/BLOCK

START AND STOP RECORD COMMANDS AND ACCESSES RECORD

224

CONTROL SYSTEMSRANGE

ACCESSORIES

• Interface to connect a cooling unit with a direct expansion heat exchanger to the AMAZON (VRF) systems.

• It has an additional indoor unit.• Power from 9 to 56 kW.• More than one unit can be connected at the same time to

increase the connectable capacity.

ACCESSORIES

KAHU NEW

INSTALLATION EXAMPLE

GENERAL CHARACTERISTICS

KAHU

MARKET CLIMATE CONTROL

INDOOR UNITS

OUTDOOR UNIT

PQE

WITH DIRECT EXPANSION BATTERY

Liquid cooling pipeline

Gas cooling pipeline

PRICE LIST

MODEL COMPATIBLE WITH PRICE

KAHU-200.2

AMAZON

£308

£369KAHU-360.2

KAHU-560.2 £492

Go back to General Contents Go back to CONTROLS Index(Index)

225

Design and Install for you

CON

TR

OLS

CON

TRO

L S

YS

TEM

S

• Digital wattmeter.• One controller for each outdoor module.• Consumption can be displayed through the KMC-32 E and

KAYNET controllers.

• This interface is necessary to connect the KSD-35 unit to a centralised controller.

K01-WATT

INTERFACE XYE ON

KO1-WATT KO1-WATT KO1-WATT KO1-WATT

O, A

, E P

OR

T

INDOOR UNITS

OUTDOOR UNITS

INSTALLATION EXAMPLE

O, A

, E P

OR

T

O, A

, E P

OR

T

O, A

, E P

OR

T

GENERAL CHARACTERISTICS

GENERAL CHARACTERISTICS

INTERFACE XYE ON

PQE

PRICE LIST

MODEL COMPATIBLE WITH PRICE

K01-WATT AMAZON £308

PRICE LIST

MODEL COMPATIBLE WITH PRICE

INTERFACE XYE ON

KSD £56

Go back to General Contents Go back to CONTROLS Index(Index)

NEXUS CHILLERS RANGE

227

Design and Install for you

INTRODUCTION TO THE PRODUCT RANGE ................................................ ..228

CHILLERS ........................................................................................................ ..232

MINICHILLERS .............................................................. KEM D(V)(T)N ......... ..234

MODULAR FULL DC INVERTER CHILLERS ................ KEM DNS3 ............... ..236

DIGITAL SCROLL MODULAR CHILLERS ..................... KEM DHN3 .............. ..238

EXTERNAL HYDRAULIC KITS ..................................... KH ..............................240

FIXED SCROLL MODULAR CHILLERS.. ...................... KEM HN3 ................... 242

SCREW CHILLERS ........................................................ KEX - A (W) ...............244

CENTRIFUGAL CHILLERS ................................................................................248

NEXUSCHILLERS RANGE

228

CHILLERS RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

CHILLERS RANGENEXUS

This year, KAYSUN UK will unveil its new Full DC Inverter models. This range will have a power of 30 and 60 kW in two versions. Modular units that can be combined in groups of up to 4 (a total maximum capacity of 240 kW) and units with a built-in hydraulic kit.

This new range complements the multiple KAYSUN UK chiller options already available.

The range of KAYSUN UK Nexus chillers is the ideal solution for a great variety of spaces that require climate control, such as hotels, offices, stores and other facilities. All units in this range use environmentally and ozone-friendly refrigerant.

MODULAR CHILLERS

KAYSUN UK offers a wide range of modular units, which provide great versatility based on its basic modules divided into 3 sub-ranges. Each of these sub-ranges has combinable units with different power levels. These units adapt to the needs of every customer and location, with capacities ranging from 30 kW (using just one module with a lower capacity) to 1000 kW (bringing together four 250 kW chillers).

MODULAR FULL DC INVERTER CHILLERS

New modular 30kW and 60kW chillers fitted with Full DC Inverter technology. Up to four modules of these units can be combined, allowing us to achieve capacities of up to 240 kW. Fitted with DC Inverter Twin Rotary compressors and DC Brushless ventilators to ensure high efficiency and with the resulting energy savings. Units designed to ensure easy access for correct maintenance and with a compact structure.

“THE FLOW OF THE MOST ADVANCED

TECHNOLOGY”

EXCHANGER TYPE These units are fitted with a plate exchanger.

OUTLET WATER

INLET WATER

OUTLET REFRIGERANT

INLET REFRIGERANT

HOT PLATE

NEW

TWIN ROTARY DC INVERTER COMPRESSORS

DC INVERTER VENTILATORS

COMPACT STRUCTURE

+++

Go back to General Contents Go back to NEXUS Index(Index)

229

Design and Install for you

NEX

US

CHIL

LER

S

WATER OUTLET

GAS OUTLET

GAS INLET

WATER INLET

PIPE IN PIPE SYSTEM

MULTI-TUBE SYSTEM

DIGITAL SCROLL AND FIXED SCROLL EXCHANGER

Digital Scroll chillers are fitted with a pipe in pipe heat exchanger for the 30kW units and with a multi-tube heat exchanger for 65kW units. Fixed Scroll chillers are fitted with a multi-tube heat exchanger.

The 30kW and 65kW chiller units are equipped with a Digital Scroll compressor plus fixed Scroll compressors. Thanks to this advanced technology it is possible to have a total control over the part-load regime of the system. The Digital Scroll compressor, with 20 second charge and discharge cycles, allows for the compressor to work continually and adapt to the needs of the user thanks to the measurement of the return water temperature.

DIGITAL SCROLL x4 COMBINABLE UNITS UP TO 260 kW FIXED SCROLL

The 130kW, 185kW and 250kW fixed Scroll chillers, can be also combined with four 250 kW units, thereby achieving 1MW of maximum cooling power.

CONDENSATION CONTROL

Condensation control integrated into all Digital Scroll and Fixed Scroll modular chillers, (from 30 to 250 kW), which allows for operation under air temperatures down to -10ºC in Cooling mode.

REFRIGERANTE

AGUA

COMBINABLE UP TO 1000 kWx4

WATER

REFRIGERANT

Go back to General Contents Go back to NEXUS Index(Index)

230

CHILLERS RANGE INTRODUCTION TO THE RANGE

OF PRODUCTS

INVERTER MINI CHILLERS

FULL DC INVERTER CHILLER UNITS WITH BUILT-IN HYDRAULIC KIT

New 30kW and 60kW Full DC Inverter chillers with built-in hydraulic kit. These units are fitted with DC Inverter Twin Rotary compressors and DC Brushless ventilators to ensure high efficiency and the resulting energy savings. Chillers designed to ensure easy access for correct maintenance and with a compact structure.

NEW

TWIN ROTARY DC INVERTER COMPRESSORS

DC INVERTER VENTILATORS

++

COMPACT STRUCTURE

BUILT-IN HYDRAULIC KIT

++

INVERTER MINI CHILLERS

Minichiller units with 5, 7, 10, 12, 14 and 16 kW rotary Inverter compressors provide up to 3.39 EER and up to 3.50 COP. This enhancement turns these units into a very efficient option to be considered for residential hot water installations.

EXCHANGER TYPE

These units are fitted with a plate exchanger.

HYDRAULIC KIT

Minichiller units are delivered with a complete built-in hydraulic kit.

ROTARY SCREW CHILLERS

KAYSUN’S NEXUS range has large chillers with screw compressors. These units can operate condensed by air or water. Besides, all units are fitted with Bitzer bi-screw compressors and regulate refrigerant through an electronic expansion valve. These units have a capacity of between 340 and 1780 kW. They also incorporate multi-tubular evaporators and control is carried out using a microprocessor with a 10.7” touchscreen.

OUTLET WATER

INLET WATER

OUTLET REFRIGERANT

INLET REFRIGERANT

HOT PLATE

Go back to General Contents Go back to NEXUS Index(Index)

231

Design and Install for you

UNITS

TECHNICAL SPECIFICATIONS

232

CHILLERS RANGE INTRODUCTION TO THE RANGE

OF PRODUCTS

POWER RANGE

5

5

5

340

14

14

225

14

540

12

12

200

12

500

10

10

180

10

440

20

20

300

20

690

INVERTER MINICHILLERS 7

7

130

7

380

16

16

250

16

600

WITHOUT HYDRAULIC KIT

AIR-WATER

SINGLE-PHASE

FIXED SCROLL

WITH HYDRAULIC KIT

DIGITAL SCROLL

WATER-WATER

THREE-PHASE

MODULARCHILLERS

SCREWCHILLERS

MODULAR FULL DC INVERTER CHILLERS

KEM-5 DVN1 KEM-7 DVN1 KEM-10 DVN KEM-12 DVN

KEM-12 DTN KEM-14 DTN KEM-16 DTN

KEX-380.1 A

KEX-340.1 AW KEX-440.1 AW KEX-540.1 AW KEX-690.1 AW

KEX-500.1 A KEX-600.1 A

KEM-130 HN3 KEM-200 HN3 KEM-250 HN3

NEW

COMBINABLE UP TO 4 MODULES

POWER kW

POWER kW

POWER kW

POWER kW

POWER kW

32 4MW

HIGH CAPACITY

CENTRIFUGALCHILLERS

CONSULT MODEL

Go back to General Contents Go back to NEXUS Index(Index)

233

Design and Install for you

NEX

US

CHIL

LER

S

30

30

400

30

805

50

50

600

50

1080

40

40

500

40

900

60

60

700

60

1385 1620

35

35

450

35

890

55

55

650

55

1200

45

45

550

45

1000

65

65

750

65

1400 1780

25

25

350

25

720

KEX-1080.2 A KEX-1200.2 A KEX-1385.2 A

KEX-900.2 A KEX-1000.2 A

KEX-805.1 AW KEX-890.1 AW KEX-1620.2 A KEX-1780.2 A

KEM-30 DNS3

KEX-720.1 A

KEM-30 DHN3 KEM-65 DHN3

Consult modelConsult model

KEM-60 DNS3

KEX-1200.2 A KEX-1400.2 A

COMBINABLE UP TO 4 MODULES

COMBINABLE UP TO 4 MODULES

6 87 95

CONSULT MODEL

Go back to General Contents Go back to NEXUS Index(Index)

234

CHILLERS RANGE MINI CHILLERS

(*) Measurement at 1 m distance and 1.5 m height. Optional KCCHT-03 wired controller

INVERTER MINICHILLERS

TECHNICAL SPECIFICATIONS

MODEL KEM-5 DVN1 KEM-7 DVN1 KEM-10 DVN KEM-12 DVN KEM-12 DTN KEM-14 DTN KEM-16 DTN

Power supply V-F-Hz 220/1/~50 220/1/~50 220/1/~50 220/1/~50 380/3/~50 380/3/~50 380/3/~50

Cooling capacitykW 5

(1.9 ~ 5.8)7

(2.1 ~ 7.8)10.0

(2.9 ~ 10.5)11.2

(3.1 ~ 12.0)11.2

(3.1 ~ 12.0)12.5

(3.3 ~ 14.0)14.5

(3.5 ~ 15.5)

kCal/h 4300 6020 8600 9632 9632 10750 12470

Cooling input kW 1.55 2.25 2.95 3.5 3.38 3.9 4.53

EER 3.23 3.11 3.39 3.20 3.31 3.20 3.20

Heating capacitykW 6.2

(2.1 ~ 7.0)8

(2.3 ~ 9.0)11.0

(3.2 ~ 12.0)12.3

(3.3 ~ 13.2)12.3

(3.3 ~ 13.2)13.8

(3.5 ~ 15.4)16.0

(3.7 ~ 17.0)

kCal/h 4730 6880 9460 10578 10578 11868 13760

Heating input kW 1.9 2.5 3.14 3.78 3.72 4.25 4.85

COP 3.26 3.20 3.50 3.25 3.31 3.25 3.30

Compressor type Rotary Rotary Rotary Rotary Rotary Rotary Rotary

No of compressors 1 1 1 1 1 1 1

Water flow rate m3/h 0.86 1.2 1.72 1.92 1.92 2.15 2.49

Max./min. water flow m3/h 0.95/0.77 1.32/1.08 1.89/1.54 2.11/1.73 2.11/1.72 2.36/1.93 2.73/2.24

Max./min. water pressure kPa 500/150 500/150 500/150 500/150 500/150 500/150 500/150

Refrigerant charge (R410A) Kg 2.5 2.5 2.8 2.8 2.8 2.9 3.2

Axial fan 1 1 2 2 2 2 2

Fan input power W 170 170 2x100 2x100 2x100 2x100 2x100

Dim. deep / wide / high mm 354x990x966 354x990x966 400x970x1327 400x970x1327 400x970x1327 400x970x1327 400x970x1327

Weight Kg 81 81 110 110 110 111 111

Sound pressure* dB (A) 58 58 59 59 62 62 62

Hydraulic connections mm DN25 (1") DN25 (1") DN32 (1 1/4") DN32 (1 1/4") DN32 (1 1/4") DN32 (1 1/4") DN32 (1 1/4")

Load loss evaporator kPa 15 15 18 18 18 18 19

Working Range ºC Cooling -5 ~ 46 / Heating -15 ~ 27

Supply water temperature ºC Cooling 4 ~ 20 / Heating 30 ~ 55

INVERTER

Calculation conditions:Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35ºC (dry bulb)Heating: inlet/outlet hot water temperature: 40/45ºC, outdoor temperature 7/6ºC (dry/wet bulb)

Go back to General Contents Go back to NEXUS Index(Index)

235

Design and Install for you

NEX

US

CHIL

LER

S

Dry contacts for start/stop, cold/heat and alarm. Connection ports for additional water pump and optional wired controller.

GENERAL CHARACTERISTICS

COMPACT DESIGN AND EASY INSTALLATION +AUTO-RESTART FEATURE+CONTROLLER INCLUDED+COMPLETE HYDRAULIC KIT +

INVERTER MINICHILLERS

PRICE LIST

INVERTER MODEL PRICE

KEM-5 DVN1 £2,173

KEM-7 DVN1 £2,375

KEM-10 DVN £3,562

KEM-12 DVN £3,802

KEM-12 DTN £3,666

KEM-14 DTN £3,817

KEM-16 DTN £4,055

Go back to General Contents Go back to NEXUS Index(Index)

236

CHILLERS RANGE FULL DC INVERTER CHILLERS

BASIC MODULES

MODULAR FULL DC INVERTER CHILLERSTECHNICAL SPECIFICATIONS

MODEL 30 DNS3 60 DNS3 90 DNS3 120 DNS3 150 DNS3 180 DNS3 210 DNS3 240 DNS3Module 30 + Module 60 1+0 0+1 1+1 0+2 1+2 0+3 1+3 0+4

Power supply V-f-Hz 380/3/~50 380/3/~50 - - - - - -

Cooling capacitykW 27.5 55 82.5 110 137.5 165 192.5 220

kCal/h 23600 47300 70900 94600 118200 141900 165500 189200

Cooling input power kW 10.9 21.8 32.7 43.6 54.5 65.4 76.3 87.2

SEERon 4.5 4.2 4.4 4.2 4.3 4.2 4.2 4.2

Heating capacity kW 31 61 92 122 153 183 214 244

kCal/h 26700 52500 79100 104900 131600 157400 184000 209800

Heating input power kW 8.50 16.05 24.55 32.1 40.6 48.15 56.65 64.2

SCOP 3.95 3.84 3.9 3.8 3.9 3.8 3.9 3.8

No. of compressors 1 2 3 4 5 6 7 8

Compressor type Double Twin Rotary DC

Number of cooling circuits 1 1 2 2 3 3 4 4

Minimum total capacity % 10% 10% 4% 5% 4% 4% 3% 3%

Evaporator Plates Plates - - - - - -

Evaporator pressure drop kPa 40 70 - - - - - -

Water flow rate m3/h 4.75 9.8 - - - - - -

Min./max. water flow m3/h 3.5~5.7 7.5~12 11~17.7 15~24 18.5~29.7 22.5~36 26~41.7 30~48

Max. water pressure MPa 1 1 1 1 1 1 1 1

Hydraulic connections Inches (mm)

11/2" (DN40) 2" (DN50) - - - - - -

Condenser Finned tube

Number of condensors 1 2 3 4 5 6 7 8

Airflow m3/h 12500 25000 - - - - - -

Control system KJRM-120H/BMWKO-E wired controller

Refrigerant load (R410A) Kg 10.5 17 - - - - - -

Number of axial venti-lators 1 2 3 4 5 6 7 8

Fan input power kW 0.75 1.5 - - - - - -

Dimensions (depth/width/height) mm 2067/805/

11522200/1065/

14602200/1870/

14602200/2130/

14602200/2935/

14602200/3195/

14602200/4000/

14602200/4260/

1460

Weight Kg 300 500 800 1000 1300 1500 1800 2000

Sound power dB (A) 78.2 83 84.2 86 86.7 87.8 88.6 89.7

Working Range ºC Cooling -15~48 / Heating -15~30

Supply water temperature ºC Cooling 0~20 / Heating 25~55

Calculation conditions:Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35ºC (dry bulb)Heating: inlet/outlet hot water temperature: 40/45ºC, outdoor temperature 7/6ºC (dry/wet bulb)

Go back to General Contents Go back to NEXUS Index(Index)

237

Design and Install for you

NEX

US

CHIL

LER

S

The new KAYSUN UK Full DC Inverter CHILLERS are available in two types of module: a 30 kW module and a 60 kW module.

The Full DC Rotary Inverter compressor and Full DC brushless ventilators provide great stability and energy efficiency.

The units are very compact and are designed to speed up maintenance.

Up to 4 modules can be combined, reaching a capacity of 240 kW.

• Full DC Inverter: The technology used in the KAYSUN UK DC INVERTERS optimises consumption, adjusting with greater accuracy to the actual demand of the system.

• Self-protection and self-diagnosis functions. Adjustment range for water outlet: from 0 to 17ºC for Cooling mode and from 22 to 50ºC for Heating mode.

• Automatic control. A single control for all the models that form the system.

• Dry contacts for start/stop, cold/ heat and alarm.

• Condensation control.

INDIVIDUAL

KCCHT-04

STANDARD CONTROLLER

KCCH-02 PS*

*Includes weekly programmer

K01-LON KEM K01- BACNET KEM*

*Requires a KCCH-02 PS

KCCHT-02 MODBUS

KCCHT-04

GENERAL CHARACTERISTICS

BMS AND SOFTWARE

SINGLE

CONTROLLER ONLY FOR AUTOMATIC CONTROL 1

OPTION WITH BUILT-IN HYDRAULIC KIT POA+

PRICE LIST

MODEL STANDARD CONTROL PRICE

KEM-30 DNS3 KCCHT-04 Price on applicationKEM-60 DNS3 KCCHT-04 Price on applicationKEM-90 DNS3 KCCHT-04 Price on applicationKEM-120 DNS3 KCCHT-04 Price on applicationKEM-150 DNS3 KCCHT-04 Price on applicationKEM-180 DNS3 KCCHT-04 Price on applicationKEM-210 DNS3 KCCHT-04 Price on applicationKEM-240 DNS3 KCCHT-04 Price on application

Go back to General Contents Go back to NEXUS Index(Index)

238

CHILLERS RANGE DIGITAL SCROLL CHILLERSDIGITAL

(*) Measurement at 1 m distance and 1.5 m height.

BASIC MODULES

DIGITAL SCROLL MODULAR CHILLERS

TECHNICAL SPECIFICATIONS

MODEL 30 DHN3 65 DHN3 95 DHN3 130 DHN3 160 DHN3 195 DHN3 225 DHN3 260 DHN3Module 30 + Module 65 1+0 0+1 1+1 0+2 1+2 0+3 1+3 0+4

Power supply V-f-Hz 380/3/~50 380/3/~50 - - - - - -

Cooling capacitykW 30 65 95 130 160 195 225 260

kCal/h 25800 55900 81700 111800 137600 167700 193500 223600

Cooling input kW 10 20.4 30.3 40.8 50.8 61.2 71.2 81.6

EER 3.00 3.19 3.14 3.19 3.15 3.19 3.16 3.20

Heating capacitykW 32 69 101 138 170 207 239 276

kCal/h 27520 59340 86860 118680 146200 178020 205540 237360

Heating input kW 9.8 21.5 31.3 43 52.8 64.5 74.3 86

COP 3.27 3.21 3.23 3.21 3.22 3.21 3.22 3.21

No. of compressors 1+1 1+2 5 6 8 9 11 12

No. of cooling circuits 2 2 4 4 6 6 8 8

Capacity control Stages Stages Stages Stages Stages Stages Stages Stages

Min. total capacity % 10 30 16 23 9.4 15 6.6 12

Evaporator Pipe in pipe Multi-tube - - - - - -

Evaporator pressure drop kPa 60 15 - - - - - -

Water flow rate m3/h 5.2 11.2 - - - - - -

Min./max. water flow m3/h 4.68/5.72 10.08/12.32 14.76/18.04 20.16/24.64 24.84/30.36 30.24/36.96 34.92/42.68 40.32/49.28

Max. water pressure MPa 1 1 1 1 1 1 1 1

Hydraulic connections Inches (mm)

1 1/2" (DN40) 4" (DN100) - - - - - -

Condenser Aluminium Fin-coil

Number of condensors 2 2 4 4 6 6 8 8

Airflow m3/h 12000 24000 - - - - - -

Control system KCCHT - 02 wired controller

Refrigerant charge (R410A) Kg 3.5x2 7x2 - - - - - -

No. of axial fans 1 2 3 4 5 6 7 8

Power input fan kW 0.67 0.865x2 - - - - - -

Dimensions (depth/width/height) mm 841x1514

x1865900x2000

x1880900x3514

x1880900x4000

x1880900x5514

x1880900x6000

x1880900x7514

x1800900x8000

x1880

Weight Kg 375 610 985 1220 1595 1830 2205 2440

Sound pressure* dB (A) 65 67 69.1 70 71.2 71.8 72.6 73

Working Range ºC Cooling -10 ~ 46 / Heating -10 ~ 21

Supply water temperature ºC Cooling 0 ~ 17 / Heating 22 ~ 50

Calculation conditions:Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35ºC (dry bulb)Heating: inlet/outlet hot water temperature: 40/45ºC, outdoor temperature 7/6ºC (dry/wet bulb)

Go back to General Contents Go back to NEXUS Index(Index)

239

Design and Install for you

NEX

US

CHIL

LER

S

KAYSUN UK Nexus Modular is available in two type of modules: one of 30kW with 2 compressors and the other of 65 kW with 3 compressors. Each unit has a "V"-type condensing coil, with a pipe in pipe exchanger for the 30kW module and a multi-tube exchanger for the 65kW module.

All models have a Digital Scroll compressor; the remaining compressors are of the fixed speed Scroll type.

Up to 4 modules can be combined, reaching a capacity of 260kW.

• Flexible combination: the connection between modules is as simple as connecting each of their inlet and outlet tubes.

• Self-protection and self-diagnosis functions. Adjustment range for water outlet: from 0 to 17ºC for Cooling mode and from 22 to 50ºC for Heating mode.

• Automatic control. A single control for all the models that form the system.

• Dry contacts for start/stop, cold/ heat and alarm.

• Condensation control.

INDIVIDUAL

KCCHT-02

KCCH-02 PS*

*Includes weekly programmer

K01-LON KEM K01- BACNET KEM*

*Requires a KCCH-02 PS

KCCHT-02 MODBUS

KCCHT-02

GENERAL CHARACTERISTICS

BMS AND SOFTWARE

SINGLE

CONTROLLER ONLY FOR AUTOMATIC CONTROL 1

STANDARD CONTROLLER

PRICE LIST

MODEL STANDARD CONTROL PRICE

KEM-30 DHN3 KCCHT-02 £6,163

KEM-65 DHN3 KCCHT-02 £9,984

KEM-95 DHN3 KCCHT-02 £16,148

KEM-130 DHN3 KCCHT-02 £19,968

KEM-160 DHN3 KCCHT-02 £26,132

KEM-195 DHN3 KCCHT-02 £29,952

KEM-225 DHN3 KCCHT-02 £36,116

KEM-260 DHN3 KCCHT-02 £39,936

Go back to General Contents Go back to NEXUS Index(Index)

240

CHILLERS RANGE EXTERNAL HYDRAULIC KITSDIGITAL

MODEL (WITH BUFFER TANK) + 1 PUMP KHX-PM3-100 KHX-A-300 KHX-B-300 KHX-C-300 KHX-D-500 KHX-F-500Buffer tank capacity litres 100 300 300 300 500 500

Expansion vessel capacity litres 18 25 25 25 25 25

Expansion vessel calibration bar 1.5 1.5 1.5 1.5 1.5 1.5

Pressure relief valve calibration bar 3 3 3 3 3 3

No. of pumps 1 1 1 1 1 1

Pump flow m3/h 5.16 11.18 16.4 22.4 27.6/31.8/33.6 38.8/43/44.8

Pressure loss mca 14.8 17 17.7 14.4 18.8/17.3/16.6 18.4/17.7/17.3

Power input kW 0.85 1.1 1.5 1.5 2.2 3

Hydraulic connections Inches 1 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 3

Power Supply V/f/Hz 230/1/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50

Dimensions Height / Width / Depth mm 1350x1120x800 1265x1504x1120 1265x1504x1120 1265x1504x1120 1265x1504x1120 1265x1504x1120

Net weight Kg 450 186 188 188 213 341

Gross weight (with water) Kg 550 486 488 488 713 841

MODEL (WITH BUFFER TANK) + DOUBLE PUMP KH2X-PM3-100 KH2X-A-300 KH2X-B-300 KH2X-C-300 KH2X-D-500 KH2X-F-500Buffer tank capacity litres 100 300 300 300 500 500

Expansion vessel capacity litres 18 25 25 25 25 25

Expansion vessel calibration bar 1.5 1.5 1.5 1.5 1.5 1.5

Pressure relief valve calibration bar 3 3 3 3 3 3

No. of pumps 2 2 2 2 2 2

Pump flow m3/h 5.16 11.18 16.4 22.4 27.6/31.8/33.6 38.8/43/44.8

Pressure loss mca 14.8 17 17.7 14.4 18.8/17.3/16.6 18.4/17.7/17.3

Power input kW 0.85 1.1 1.5 1.5 2.2 3

Hydraulic connections Inches 1 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 3

Power Supply V/f/Hz 230/1/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50

Dimensions Height / Width / Depth mm 1350x1120x800 1265x1504x1120 1265x1504x1120 1265x1504x1120 1265x1504x1120 1265x1504x1120

Net weight Kg 488 216 220 220 247 428

Gross weight (with water) Kg 588 516 520 520 747 928

MODEL (WITHOUT BUFFER TANK) + 1 PUMP KHX-PM3 KHX-A KHX-B KHX-C KHX-D KHX-FBuffer tank capacity litres - - - - - -

Expansion vessel capacity litres 12 12 12 12 12 25

Expansion vessel calibration bar 1.5 1.5 1.5 1.5 1.5 1.5

Pressure relief valve calibration bar 3 3 3 3 3 3

No. of pumps 1 1 1 1 1 1

Pump flow m3/h 5.16 11.18 16.4 22.4 27.6/31.8/33.6 38.8/43/44.8

Pressure loss mca 14.8 17 17.7 14.4 18.8/17.3/16.6 18.4/17.7/17.3

Power input kW 0.85 1.1 1.5 1.5 2.2 3

Hydraulic connections Inches 1 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 3

Power Supply V/f/Hz 230/1/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50

Dimensions Height / Width / Depth mm 1350x800x650 1350x800x650 1350x800x650 1350x800x650 1350x800x650 1350x1120x800

Net weight Kg 88 89 90 91 93 153

EXTERNAL HYDRAULIC KITS TECHNICAL SPECIFICATIONS

Go back to General Contents Go back to NEXUS Index(Index)

241

Design and Install for you

NEX

US

CHIL

LER

S

1 Tank

2 Water pump

3 Expansion vessel

5 On-off valve

6 Safety valve

7 Pressure gauge

8 Pressure relief valve

10 Automatic filling unit

11 Electric panel

12 Control valve

(version with 2 pumps only)

13 Drain

14 Anchor points

(no. 4-6 holes M12/Ø14)

15 Power Supply

16 Hoist points

17 Flow to the device

18 Return from the device

CHILLERS KEM-30 DNS3

KEM-30 DHN3

KEM-60 DNS3

KEM-65 DHN3

KEM-90 DHN3

KEM-95 DHN3

KEM-120 DNS3

KEM-130 DHN3

KEM-130 HN3

KEM-150 DNS3

Compatiblehydraulic kits*

KH-PM3 KH-PM3 KHX-A KHX-A KHX-B KHX-B KHX-C KHX-C KHX-C KHX-D

KHX-PM3-100 KHX-PM3-100 KHX-A-300 KHX-A-300 KHX-B-300 KHX-B-300 KHX-C-300 KHX-C-300 KHX-C-300 KHX-D-500

KH2X-PM3-100 KH2X-PM3-100 KH2X-A-300 KH2X-A-300 KH2X-B-300 KH2X-B-300 KH2X-C-300 KH2X-C-300 KH2X-C-300 KH2X-D-500

CHILLERSKEM-160

DHN3KEM-180

DNS3KEM-195

DHN3KEM-200

HN3KEM-210

DNS3KEM-225

DHN3KEM-240

DNS3KEM-250

HN3KEM-260

DHN3

Compatiblehydraulic kits*

KHX-D KHX-D KHX-D KHX-D KHX-F KHX-F KHX-F KHX-F KHX-F

KHX-D-500 KHX-D-500 KHX-D-500 KHX-D-500 KHX-F-500 KHX-F-500 KHX-F-500 KHX-F-500 KHX-F-500

KH2X-D-500 KH2X-D-500 KH2X-D-500 KH2X-D-500 KH2X-F-500 KH2X-F-500 KH2X-F-500 KH2X-F-500 KH2X-F-500

(*)These application tables are for guidance purposes only. The final decision is to be made by the installer.

GENERAL CHARACTERISTICS

PRICE LIST

MODEL PRICE

Tank + PumpKHX-PM3-100 £2,845KHX-A-300 £4,466KHX-B-300 £4,527KHX-C-300 £4,558KHX-D-500 £4,620KHX-F-500 £5,048Tank + 2 PumpsKH2X-PM3-100 £4,675KH2X-B-300 £5,790KH2X-A-300 £5,759KH2X-C-300 £5,821KH2X-D-500 £5,944KH2X-F-500 £6,960Without tank + PumpKHX-PM3 £2,032KHX-A £3,163KHX-B £3,187KHX-C £3,203KHX-D £3,223KHX-F £4,364

Go back to General Contents Go back to NEXUS Index(Index)

242

CHILLERS RANGE COOLERS MODEL FIXED SCROLLFIXED

33

(*) Measurement at 1 m distance and 1.5 m height.

FIXED SCROLL MODULAR CHILLERS

TECHNICAL SPECIFICATIONS

MODEL KEM-130 HN3 KEM-200 HN3 KEM-250 HN3Power Supply V-f-Hz 380/3/~50 380/3/~50 380/3/~50

Cooling capacitykW 130 185 250

kCal/h 111800 159100 215000

Cooling input kW 40.8 63 78.3

EER 3.19 2.94 3.19

Heating capacitykW 138 200 270

kCal/h 118680 172000 232200

Heating input kW 43 61 80

COP 3.21 3.28 3.38

No. of compressors 4 6 8

No. of cooling cycles 4 6 4

Min. total capacity % 25 17 25

Evaporator Multi-tube Multi-tube Multi-tube

Evaporator pressure drop kPa 25 30 40

Water flow rate m3/h 22.4 31.8 43

Min./max. water flow m3/h 18.54/22.66 27.90/34.10 38.70/47.30

Max. water pressure MPa 1 1 1

Hydraulic connections Inches (mm)

2 1/2" (DN65) 3" (DN80) 4" (DN100)

Condenser Aluminium Fin-coil

Airflow m3/h 48000 72000 96000

Control system KCCHT - 02 wired controller

Refrigerant charge (R410A) Kg 7x4 7x6 15x4

No. of axial fans 4 6 8

Fan input power kW 0.865x4 0.865x6 0.7x8

Dimensions (depth/width/height) mm 1685x2000x2080 2000x2850x2110 2000x3800x2130

Weight Kg 1150 1730 2450

Sound pressure* dB (A) 70 74 74

Working Range ºC Cooling -10 ~ 46 / Heating -10 ~ 21

Supply water temperature ºC Cooling 0 ~ 17 / Heating 22 ~ 50

Calculation conditions:Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35ºC (dry bulb)Heating: inlet/outlet hot water temperature: 40/45ºC, outdoor temperature 7/6ºC (dry/wet bulb)

Go back to General Contents Go back to NEXUS Index(Index)

243

Design and Install for you

NEX

US

CHIL

LER

S

COMBINABLE UP TO 1000 kWx4

GENERAL CHARACTERISTICS

INDIVIDUAL

KCCHT-02

STANDARD CONTROLLER

BMS AND SOFTWARE

SINGLE

The KAYSUN UK NEXUS range continues to grow and completes its range of chillers with new fixed Scroll compressor modular units of 130, 200 and 250kW each, thereby providing great solutions designed to cover the needs of our customers.

Equipped with 4, 6 and 8 compressors respectively, a "V"-type condensing coil and a multi-tube heat exchanger, these units provide a better capacity reach for the KAYSUN UK NEXUS range units.

Just as versatile as lesser capacity units, these fixed Scroll compressor modular chillers can form modules of up to 4 units, arriving to capacities of 1000 kW.

• Flexible combination: the connection between modules is as simple as connecting each of their inlet and outlet tubes.

• Self-protection and self-diagnosis functions. Adjustment range for water outlet: from 0 to 17ºC for Cooling mode and from 22 to 50ºC for Heating mode.

• Automatic control. A single control for all the models that form the system.

• Dry contacts for start/stop, cold/ heat and alarm.

• Condensation control.

• Anti-icing function.

KCCH-02 PS*

*Includes weekly programmer

K01-LON KEM K01- BACNET KEM*

*Requires a KCCH-02 PS

KCCHT-02 MODBUSKCCHT-02

PRICE LIST

MODEL STANDARD CONTROL PRICE

KEM-130 HN3 KCCHT-02 £18,412

KEM-200 HN3 KCCHT-02 £27,017

KEM-250 HN3 KCCHT-02 £36,065

Go back to General Contents Go back to NEXUS Index(Index)

244

CHILLERS RANGE SCREW CHILLERS

(*) Measurement at 1 m distance and 1.5 m height.

MODEL KEX 380.1 A KEX 500.1 A KEX 600.1 A KEX 720.1 A KEX 900.2 A KEX1000.2 A KEX1200.2 A KEX1400.2 A Power Supply V/f/Hz 380V/3P+N+PE/ 50Hz

Cooling capacitykW 376 496 594 720 902 996 1203 1419

kCal/h 323360 426560 510840 619200 775720 856560 1034580 1220340

Cooling input kW 124 159 187 234 285 318 381 466

EER 3.03 3.12 3.18 3.08 3.16 3.13 3.16 3.05

Refrigerant load (R134A) Kg 76 90 105 140 76+90 90+90 105+105 140+140

Refrigerant control ELECTRIC EXPANSION VALVE

Compressor type Semi-hermetic bi-screw compressor

No. of compressors 1 1 1 1 2 2 2 2

Oil load by compressor L 30 30 30 32 30+30 30+30 30+30 32+32

Capacity control (adjustable) % 25%, 50%, 75%, 100%, 4 steps 12.5%, 25%, 37.5%, 50%, 62.5%, 75%, 87.5%, 100%

Motor overloadprotection ELECTRONIC

Oil lubrication INJECTION

Number of fans 6 8 10 10 14 16 16 20

Airflow m3/h 23000x6 23000x8 23000x10 23000x10 23000x14 23000x16 23000x16 23000x20

Motor input power kW 2.4x6 2.4x8 2.4x10 2.4x10 2.4x14 2.4x16 2.4x16 2.4x20

Motor speed rpm 940 940 940 940 940 940 940 940

Evaporator type Multi-tube exchanger

Water volume m3 0.222 0.308 0.340 0.520 0.620 0.600 0.770 0.910

Water flow rate m3/h 65.4 86 103.2 123.8 154.8 172 206.4 244.2

Load loss kPa 39 54 56 58 74 75 71 69

Water pipe connection mm DN125 DN125 DN125 DN150 DN150 DN150 DN200 DN200

L mm 3810 4680 5800 5800 8800 9640 9640 11700

Width mm 2280 2280 2280 2280 2280 2280 2280 2280

H mm 2370 2370 2370 2370 2430 2430 2430 2430

Gross weight Kg 3320 4330 5000 5500 7750 8900 9100 11100

Working weight Kg 3540 4640 5340 6020 8370 9500 9870 12010

Outlet range ºC 5 ~ 15

Working Range ºC 15 ~ 43

1 CIRCUIT 2 CIRCUITS

AIR COOLED SCREW CHILLERS

TECHNICAL SPECIFICATIONS

Calculation conditions:Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35/24ºC (dry-/wet-bulb)

Go back to General Contents Go back to NEXUS Index(Index)

245

Design and Install for you

NEX

US

CHIL

LER

S

INVERTED "M"-SHAPED AIR CONDENSER

M

These range of chillers are equipped with 4-phase choking Bitzer bi-screw compressors.

KAYSUN UK offers 8 modules with 1 and 2 cooling circuits in order to cover an expansive capacity range, from 380 up to 1420 kW.

• Controlled by integrated microprocessor with touch screen.

• Multi-tube evaporator.

• R134a refrigerant.

• Inverted "M"-shaped air condenser

• Class "F" Isolation and IP54 protection.

GENERAL CHARACTERISTICS

PRICE LIST

MODEL PRICE

KEX 380.1 A £59,062

KEX 500.1 A £69,744

KEX 600.1 A £77,912

KEX 720.1 A £108,071

KEX 900.2 A £121,894

KEX 1000.2 A £130,691

KEX 1200.2 A £158,337

KEX 1400.2 A £182,841

Go back to General Contents Go back to NEXUS Index(Index)

246

CHILLERS RANGE SCREW CHILLERS

33

(*) Measurement at 1 m distance and 1.5 m height.

WATER-COOLED SCREW CHILLERS

TECHNICAL SPECIFICATIONS

MODEL KEX 340.1AW KEX 440.1AW KEX 540.1AW KEX 690.1AW KEX 805.1AW KEX 890.1AW KEX 1080.2AWPower Supply V/f/Hz 380V/3P+N+PE/ 50Hz

Cooling capacitykW 340 440 540 690 805 890 1080

kCal/h 292400 378400 464400 593400 692300 765400 928800

Cooling input kW 60 77 94 120 140 155 186

EER 5.67 5.71 5.74 5.75 5.75 5.74 5.81

Refrigerant load (R134A) Kg 130 145 160 200 230 250 170+170

Refrigerant control Electric expansion valve

Controller type Semi-hermetic bi-screw compressor

No. of compressors 1 1 1 1 1 1 2

Motor overload protection Electronic

Oil lubrication Through differential pressure

Evaporator Flooded multi-tube type

Water volume L 150 170 190 210 240 270 350

Water flow rate m3/h 58 76 93 119 138 153 186

Load loss kPa 55 49 53 46 39 39 78

Type of connection Victaulic

Condenser Multi-tube type

Water volume L 150 170 190 210 240 270 350

Water flow rate m3/h 73 95 116 148 173 191 232

Load loss kPa 75 70 77 66 56 56 88

Type of connection Victaulic

Evaporator type Multi-tube exchanger

Length mm 3550 3550 3550 3600 3600 3600 9640

Width mm 1200 1220 1220 1420 1440 1440 2280

H mm 1730 1800 1900 2000 2020 2020 2370

Working weight Kg 2700 2820 3220 3870 4420 4550 7250

Calculation conditions:Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35/24ºC (dry-/wet-bulb)Cooling water inlet/outlet 30/35ºC

The fouling factor of the evaporator and condenser is 0.086m2·ºC/kW

1. Input2. Motor3. Screw4. Poppet valve5. Output6. Oil separator7. Bearing8. Electric resistance

of the oil pan9. Oil filter

Go back to General Contents Go back to NEXUS Index(Index)

247

Design and Install for you

NEX

US

CHIL

LER

S

• This range includes the latest generation of semi-hermetic bi-screw compressors.

• The evaporator has a flooded multi-tube system while the condenser's system in multi-tube. Both are high-efficiency elements.

• Separate circuits for each compressor.

• The built-in control switchboard is fitted with a 7" touch screen to provide user with a comfortable and easy interaction with its interface.

• Type of refrigerant required: R134a.

• Class "F" Isolation and IP54 protection.

• Oil separation in three stages to ensure the perfect lubrication of the compressor.

• Auto-restart function to keep last configuration active.

• Refrigerant regulation through electronic expansion valve.

GENERAL CHARACTERISTICSMODEL KEX 340.1AW KEX 440.1AW KEX 540.1AW KEX 690.1AW KEX 805.1AW KEX 890.1AW KEX 1080.2AWPower Supply V/f/Hz 380V/3P+N+PE/ 50Hz

Cooling capacitykW 340 440 540 690 805 890 1080

kCal/h 292400 378400 464400 593400 692300 765400 928800

Cooling input kW 60 77 94 120 140 155 186

EER 5.67 5.71 5.74 5.75 5.75 5.74 5.81

Refrigerant load (R134A) Kg 130 145 160 200 230 250 170+170

Refrigerant control Electric expansion valve

Controller type Semi-hermetic bi-screw compressor

No. of compressors 1 1 1 1 1 1 2

Motor overload protection Electronic

Oil lubrication Through differential pressure

Evaporator Flooded multi-tube type

Water volume L 150 170 190 210 240 270 350

Water flow rate m3/h 58 76 93 119 138 153 186

Load loss kPa 55 49 53 46 39 39 78

Type of connection Victaulic

Condenser Multi-tube type

Water volume L 150 170 190 210 240 270 350

Water flow rate m3/h 73 95 116 148 173 191 232

Load loss kPa 75 70 77 66 56 56 88

Type of connection Victaulic

Evaporator type Multi-tube exchanger

Length mm 3550 3550 3550 3600 3600 3600 9640

Width mm 1200 1220 1220 1420 1440 1440 2280

H mm 1730 1800 1900 2000 2020 2020 2370

Working weight Kg 2700 2820 3220 3870 4420 4550 7250

KEX 1200.2AW KEX 1385.2AW KEX 1620.2AW KEX 1780.2AW380V/3P+N+PE/ 50Hz

1200 1385 1620 1780

1032000 1191100 1393200 1530800

206 238 278 306

5.83 5.82 5.83 5.82

180+180 190+190 210+210 220+200

Electric expansion valve

Semi-hermetic bi-screw compressor

2 2 2 2

Electronic

Through differential pressure

Flooded multi-tube type

400 460 520 580

206 238 279 306

79 79 75 76

Victaulic

Multi-tube type

400 460 520 560

258 298 348 383

87 87 85 86

Victaulic

Multi-tube exchanger

9640 11700 11700 11700

2280 2280 2280 2280

2370 2370 2370 2370

7490 7820 9200 9350

PRICE LIST

MODEL PRICE £

KEX 340.1 AW £37,591

KEX 440.1 AW £45,038

KEX 540.1 AW £51,021

KEX 690.1 AW £63,173

KEX 805.1 AW £73,629

KEX 890.1 AW £80,708

KEX 1080.2 AW £99,194

KEX 1200.2 AW £106,552

KEX 1385.2 AW £122,751

KEX 1620.2 AW £150,021

KEX 1780.2 AW £165,459

Go back to General Contents Go back to NEXUS Index(Index)

248

CHILLERS RANGE CENTRIFUGAL CHILLERS

CHILLERS RANGE

CENTRIFUGAL CHILLERS

KAYSUN UK introduces its most powerful range of chillers, thanks to the addition of centrifugal compressors.They are available in three different options according on their efficiency. From standard units to high-efficiency and, eventually, super high-efficiency units, with 7.11 EER.

All our units use R134a, an environmentally friendly refrigerant with a low GWP (Global Warming Potential), which results in maximum performance.

STANDARD EFFICIENCY

The Standard Efficiency range units are available with two different type of configurations. One consists of a power range between 1.58MW to 4.22MW, a single compression stage and a flooded multi-tube type evaporator.

The second configuration consists of two stages and a full falling film multi-tube evaporator, which results in higher cooling power, from 4.57 MW to 7.73 MW. All these units provide between 5.3 and 5.7 EER.

WHAT IS "FULL FALLING FILM"?It is the latest in refrigerant savings systems. This new concept allows using 40% less refrigerant than the traditional flooded multi-tube type evaporator, and increases the energy exchange rate between 3% and 8%.

HOW DOES IT WORK?

The liquid refrigerant falls as a liquid as rain between the pipes and evaporates as it fills the various levels of the installation.

This way, only a small percentage of refrigerant reaches the bottom of the evaporator.

“THE HIGHESTPOWER AT YOUR

SERVICE"

40% reduction in refrigerant charge

Flooded type

The falling film reaches

around 40% of the refrigerant charge

compared with the flooded type.

Full falling film

Almost 0% of liquid level

PATENTED

Go back to General Contents Go back to NEXUS Index(Index)

249

Design and Install for you

NEX

US

CHIL

LER

S

HIGH EFFICIENCY

High efficiency chillers are one-step ahead. They are divided into two different configurations. One consists of a one-stage centrifugal compressor and a flooded evaporator, which results in a power range from 2.46MW to 4.22MW. The second configuration consists of a two-stage compressor and an evaporator including the Full Falling Film system. High Efficiency units provide from 5.6 to 6.8 EER.

GUARANTEE OF SUCCESS

In order to ensure the perfect operation of its high-capacity chillers, KAYSUN UK performs tests on all of its units. This way, the company is able to guarantee that its products will comply with all the established requirements.

CONTROL PANEL

All centrifugal units are fitted with an easy to access control panel. They also include a 10.4 inches LCD touch screen to display graphic views of the chiller. The screen is easy to access. It communicates with PCs, starts and stops the unit remotely and provides more than 30 protection functions that can be checked in the 10 last failure reports.

SUPER HIGH EFFICIENCY

The KAYSUN UK Super High Efficiency range include units with 7.11 EER, which turns them into the most efficient product in the market, considering their performance. These units can reach up to 7.73 MW with a two-stage centrifugal compressor fitted with a multi-tube evaporator including the new full falling film system.

Go back to General Contents Go back to NEXUS Index(Index)

FANCOILSWATER TERMINAL UNITS PRODUCT RANGE

251

Design and Install for you

FANCOILSWATER TERMINAL UNITS PRODUCT RANGE

INTRODUCTION TO THE PRODUCT RANGE ......................................252

UNITS WALL-MOUNTED ......................................KFC-AY ....................255

CEILING/FLOOR .........................................KFC-S(E) ..................257

CASSETTES 600x600 ................................KFC-CI ......................259

CASSETTES ................................................KFC-CIS ....................261

DUCTS .........................................................KFC-PD ....................263

HIGH PRESSURE DUCTS ...........................KFC-PDH ..................265

252

WATER TERMINALUNITS

INTRODUCTION TO THE RANGE OF PRODUCTS

The Cassette 600x600 and Cassette 840x840 units and low profile duct unit are available with 2 and 4 pipes configurations.

The four-duct configurations allow units to work in Cooling mode and in Heating mode simultaneously and separately in the same installation.

Four-duct coils are fitted with two rows to work in Cooling mode, and with one row to work in Heating mode.The Duct and Cassette units include a standard extended drain pan.

The Fancoil Cassette and Duct type units have an optional L-shaped pipework kit for easy installation.

WATER TERMINAL UNITS RANGE FANCOILS

The KAYSUN UK Fancoils product range uses an interface which makes conventional fan coils units compatible with KAYSUN UK electronics. There are two versions, a 2-duct version and a 4-duct version. This interface includes the electronic devices, a connector for wire controllers and sensors. Besides, it makes the Fancoil Ducts and Ceiling/Floor units compatible with direct expansion controls (wall-mounted and cassettes units are already compatible by default).

As an alternative, KAYSUN UK offers a conventional thermostat for the 2-duct and 4-duct systems. It includes two switches (hot/off /cold and 3 speeds), a temperature dial switch and a built-in sensor.

UNITS AVAILABLE FOR 2 AND 4 PIPES SYSTEMS

CONTROL

THERMOSTAT

INTERFACE TO CONTROL

“THE COMFORT OF WATER”

The FANCOIL range completes the existing NEXUS chillers range. The indoor units of this range have different type of models, such as wall-mounted, Ceiling/Floor, cassette 600x600, cassette 840x840, ducts and high static pressure ducts. All they are the perfect solution for any environment.

Go back to General Contents Go back to FANCOILS Index(Index)

253

Design and Install for you

FAN

COIL

SFA

NCO

ILS

425

425

510

1020

425

1700 2000 2380 2550 3060 3740

510 680 850 1020 1250 1360

1250 1360 1600 1700 2000 2380 2550

510

510

680

680

680

850

850

850

1020

1360

WALL-MOUNTED 2 PIPES

CASSETTES 600x600

CEILING/FLOOR 2 PIPES

CASSETTES

Ducts

HIGH STATIC PRESSURE DUCTS 2 PIPES

AIRFLOW (m3/h)

AIRFLOW (m3/h)

AIRFLOW (m3/h)

AIRFLOW (m3/h)

AIRFLOW (m3/h)

AIRFLOW (m3/h)

POWER RANGE

KFC-AY-2T-250

KFC-CI-2T-300

KFC-CIS-2T-600

KFC-PD-2T-300-1KFC-PD-2T-200-1

KFC-PD-4T-300-1KFC-PD-4T-200-1

KFC-PD-2T-400-1

KFC-PDH-2T-1000 KFC-PDH-2T-1400 KFC-PDH-2T-1800 KFC-PDH-2T-2200

KFC-PD-4T-400-1

KFC-PD-2T-600-1

KFC-PD-4T-600-1

KFC-PD-2T-800-1

KFC-PD-4T-800-1

KFC-CIS-4T-600

KFC-CIS-2T-750

KFC-CIS-4T-950

KFC-CIS-2T-1200 KFC-CIS-2T-1500

KFC-CIS-4T-1500

KFC-CI-4T-300

KFC-AY-2T-400 KFC-AY-2T-600

KFC-CI-2T-500

KFC-CI-4T-500

2 PIPES

4 PIPES

2 PIPES

2 PIPES

KFC-SE-2T-250 KFC-SE-2T-300 KFC-SE-2T-400 KFC-SE-2T-500 KFC-SE-2T-800

CONCEALED

4 PIPES

4 PIPES

1530

KFC-S-2T-250-1 KFC-S-2T-300-1 KFC-S-2T-400-1 KFC-S-2T-500-1 KFC-S-2T-900-1

EXPOSED

Go back to General Contents Go back to FANCOILS Index(Index)

254

Design and Install for you

UNITS

TECHNICAL SPECIFICATIONS

255

WATER TERMINALUNITS

WALL-MOUNTED

MODEL KFC-AY-2T-250 KFC-AY-2T-400 KFC-AY-2T-600

Cooling capacity (high)Total kW 2.63 3.28 5

Sensitive kW 1.81 2.26 3.44

Heating capacity kW 3.36 4.37 6.7

Power Input W 24 40 66

Airflow (high / medium / low) m3/h 425/360/320 680/580/510 1020/870/770

Unit dimensions

Height mm 290 290 315

Width mm 915 915 1072

Depth mm 230 230 230

Indoor unit net weight Kg 13 13.3 15.8

Sound pressure (low) dB (A) 20 26 29

Hydraulic connections Ø Inches 3/4 3/4 3/4

Evaporator pressure dropCooling kPa 29.4 43.5 42.5

Heating kPa 27.3 40.8 39.7

Water flow rate m3/h 0.45 0.56 0.86

WALL-MOUNTED

TECHNICAL SPECIFICATIONS2 PIPES

*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb. Heating: water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed. Same water flow as in Heating mode.

Go back to General Contents Go back to FANCOILS Index(Index)

256

Design and Install for you

FAN

COIL

SFA

NCO

ILS

Wall-mounted units with a compact and elegant design. They include a LED display located at the side of the unit that provides it with a modern design by using the most advanced technology in the market.

• The same appearance as the KAYF unit.

• 2 Pipes.

• Standard 3-way on/off valve included.

KID-02 S

*Recommended Kaysun controller.

COMPATIBLE WITH ALL THE KAYSUN CONTROLLERS RANGE+SAME APPEARANCE AS THE KAYF UNIT+

GENERAL CHARACTERISTICS

PRICE CALCULATED BASED ON THE STANDARD OR RECOMMENDED CONTROL

If you want a different control, you should add to the € price for the set the price difference

between the standard or recommended control and the selected control

INDIVIDUAL WIRELESS

INDIVIDUAL WIRED

CENTRALISED BMS AND SOFTWARE

KID-02 SKI-02.3 S

KC-01 S KC-02.1 HKCT-02.1 SR

KCC-64 I PSKCC-16KCCT-64 IKCC-64 WEB

K01-LONK01-KNX

K02-MODBUSKAYNET CONTROL

K01-BACNET K01-WIFI

KAYSUN CONTROLLERS

ELIGE TU CONTROL

CHOOSE YOUR CONTROL

PRICE LIST

MODEL RECOMMENDED CONTROL PRICE

KFC-AY-2T-250 KID-02 S £300

KFC-AY-2T-400 KID-02 S £304

KFC-AY-2T-600 KID-02 S £346

Go back to General Contents Go back to FANCOILS Index(Index)

257

WATER TERMINALUNITS

CEILING/FLOOR

CEILING/FLOOR

MODEL KFC-S-2T-250-1 KFC-S-2T-300-1 KFC-S-2T-400-1 KFC-S-2T-500-1 KFC-S-2T-900-1

Cooling capacity (high)

Total kW 1.87 2.53 3.27 4.85 7.85

Sensitive kW 1.29 1.74 2.25 3.34 5.4

Heating capacity kW 2.53 3.49 4.58 6.98 11.69

Power Input W 45 44 46 49 137

Airflow (high/medium/low) m3/h 425/360/320 510/430/380 680/580/510 850/720/640 1530/1300/1150

Indoor unit dimensions

Height mm 592 592 592 592 592

Width mm 800 1000 1000 1200 1500

Depth mm 220 220 220 220 220

Net weight of indoor unit Kg 22.5 26 26 32.5 39

Sound pressure (low) dB (A) 30 32 34 38 42

Hydraulic connections Ø Inches 3/4 3/4 3/4 3/4 3/4

Pressure loss evaporator

Cooling kPa 10.1 14.2 26.3 20 24.3

Heating kPa 8.8 13.7 24 17.4 21.5

Water flow rate m3/h 0.31 0.44 0.56 0.83 1.35

MODEL KFC-SE-2T-250 KFC-SE-2T-300 KFC-SE-2T-400 KFC-SE-2T-500 KFC-SE-2T-800

Cooling capacity (high)

Total kW 1.87 2.53 3.27 4.85 6.52

Sensitive kW 1.29 1.74 2.25 3.34 4.49

Heating capacity kW 2.53 3.49 4.58 6.98 9.58

Power Input W 45 44 46 49 118

Airflow (high/medium/low) m3/h 425/360/320 510/430/380 680/580/510 850/720/640 1360/1160/1020

Indoor unit dimen-sions

Height mm 545 545 545 545 545

Width mm 550 750 750 950 1250

Depth mm 212 212 212 212 212

Net weight of indoor unit Kg 17 20 20 25 32

Sound pressure (low) dB (A) 28 30 32 36 38

Hydraulic connections Ø Inches 3/4 3/4 3/4 3/4 3/4

Pressure loss evaporator

Cooling kPa 10.1 14.2 26.3 20 21

Heating kPa 8.8 13.7 24 17.4 20.2

Water flow rate m3/h 0.31 0.44 0.56 0.83 1.12

TECHNICAL SPECIFICATIONS2 PIPES

EXPOSED

CONCEALED

*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb.Heating: water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed.Same water flow as in Heating mode.

*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb.Heating: water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed.Same water flow as in Heating mode.

Go back to General Contents Go back to FANCOILS Index(Index)

258

Design and Install for you

FAN

COIL

SFA

NCO

ILS

GENERAL CHARACTERISTICS

This unit is especially designed to save space. Due to its reduced depth, it is the perfect solution that adapts to every type of installation, from wall-mounted to floor standing,

whether totally or partially recessed, adapting perfectly to the aesthetics of the environment.• 2 ducts

COMPATIBLE ACCESSORIES

KV3-FC 3/4 KC-FCS-2T

IT INCLUDES: • 3 BUTTONS

ON/OFF HOT/COLD 3 SPEEDS

• DIRECTIONAL BUTTONS FOR INCREASING/REDUCING TEM-PERATURE

KC-FC-2T KACT-0

COMPATIBLE WITH

COMPATIBLE WITH

ThermostatKC-FC-2T

Thermostat KC-FCS-2T

Interface to control

+

or

K01-FC-2T

*Kaysun thermostat recommended for

exposed units.

*It can be integrated in the body of the exposed CEILING/

FLOOR type unitsCOMPATIBLE WITH AA WIDE RANGE OF CONTROLLERS+HORIZONTAL/VERTICAL INSTALLATION+

INDIVIDUAL WIRED

CENTRALISED BMS AND SOFTWARE

KC-01 S KC-02.1 H KCT-02.1 SR

KCC-64 I PS KCC-16 KCCT-64 I KCC-64 WEB

K01-LON K01-KNX

K02-MODBUS KAYNET CONTROL

K01-BACNET K01-WIFI

KAYSUN CONTROLLERS

ELIGE TU CONTROL

CHOOSE YOUR CONTROL

PRICE LIST

MODEL PRICE

KFC-S-2T-250-1 £197

KFC-S-2T-300-1 £213

KFC-S-2T-400-1 £217

KFC-S-2T-500-1 £285

KFC-S-2T-900-1 £317

KFC-SE-2T-250-1 £166

KFC-SE-2T-300-1 £188

KFC-SE-2T-400-1 £191

KFC-SE-2T-500-1 £253

KFC-SE-2T-800-1 £283

MODEL DESCRIPTION PRICE

KV3-FC 3/4 3-way valve 3/4 £26

KACT-O On/off actuator £22

KC-FC-2T Thermostat 2 Pipes £34

ACCESSORIES

MODEL DESCRIPTION PRICE

KIT TUB FC S(E)-2T-1 Pipework kit for CEILING/FLOOR 2T valve £67

KC-FCS-2TSpecial thermostat (recommended for EXPOSED units)

£49

K02-FC-2T Interface to KAYSUN controller £154

Go back to General Contents Go back to FANCOILS Index(Index)

259

WATER TERMINALUNITS

CASSETTES

MODEL KFC-CI-2T-300 KFC-CI-2T-500

Cooling capacity (high)Total

kW3 4.5

Sensitive 2.06 3.1

Heating capacity kW 4 6

Power Input W 50 95

Airflow (high/medium/low) m3/h 510/440/360 850/730/600

Indoor unit dimensions

Height mm 261 261

Width mm 575 575

Depth mm 575 575

Net weight of indoor unit Kg 17.5 17.5

Panel dimensions

Height mm 50 50

Width mm 647 647

Depth mm 647 647

Panel net weight Kg 3 3

Sound pressure (low) dB (A) 28 34

Hydraulic connections Ø Inches 3/4 3/4

Evaporator pressure drop Cooling kPa 14 16

Heating kPa 14 16

Water flow rate m3/h 0.52 0.77

MODEL KFC-CI-4T-300 KFC-CI-4T-500

Cooling capacity (high)Total

kW2.5 3.5

Sensitive 1.72 2.41

Heating capacity kW 3.7 5.1

Power Input W 50 95

Airflow (high/medium/low) m3/h 510/440/360 850/730/600

Indoor unit dimensions

Height mm 261 261

Width mm 575 575

Depth mm 575 575

Net weight of indoor unit Kg 17.5 17.5

Panel dimensions

Height mm 50 50

Width mm 647 647

Depth mm 647 647

Panel net weight Kg 3 3

Sound pressure (low) dB (A) 28 34

Hydraulic connections Ø Inches 3/4 3/4

Evaporator pressure drop Cooling kPa 22 24

Heating kPa 17 27

Water flow rate m3/h 0.43 0.6

CASSETTES 600x600

TECHNICAL SPECIFICATIONS

2 PIPES

4 PIPES

*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb. Heating: water inlet/outlet temperature 70/60ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed. Same water flow as in Heating mode.

*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb. Heating: water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed. Same water flow as in Heating mode.

Go back to General Contents Go back to FANCOILS Index(Index)

260

Design and Install for you

FAN

COIL

SFA

NCO

ILS

COMPATIBLE ACCESSORIES 2 PIPES

KIT TUB FC CI-2T KV3-FC 3/4 KACT-0

COMPATIBLE ACCESSORIES 4 PIPES

TUB FC CI-4T KIT KV3-FC 1/2KV3-FC 3/4

KACT-0

With its new 360º panel, the Art Flux cassette provides even, fast and far-reaching air-conditioning control, without leaving dead zones. Since the main unit and panel are compact (570mm width and depth), they are lighter and require less space and equipment to be installed. They can be completely integrated into any space, including shallow ceilings, without sticking out. • Condensation pump.• Fresh air supply and air blow towards adjacent rooms.

• Standard extended drainage pan.• Optional pipework kit.• Optional three-way valve.• Optional on/off valve driver• XYE ON interface necessary for centralised/built-in

controllers (optional).

CASSETTE 600x600 2 PIPES CASSETTE 600x600 4 PIPES

KID-02 S

*Kaysun controller

recommended

COMPATIBLE WITH ALL THE KAYSUN CONTROLLERS RANGE+

SAME PANEL AS VRF - ART FLUX 360º UNITS+

GENERAL CHARACTERISTICS

PRICE CALCULATED BASED ON THE STANDARD OR RECOMMENDED CONTROL

If you want a different control, you should add to the € price for the set the price difference

between the standard or recommended control and the selected control

INDIVIDUAL WIRELESS

INDIVIDUAL WIRED

CENTRALISED BMS AND SOFTWARE

KID-02 SKI-02.3 S

KC-01 S KC-02.1 HKCT-02.1 SR

KCC-64 I PSKCC-16KCCT-64 IKCC-64 WEB

K01-LONK01-KNX INTERFACE XYE ON

K02-MODBUSKAYNET CONTROL

K01-BACNET K01-WIFI

KAYSUN CONTROLLERS ELIGE TU CONTROL

CHOOSE YOUR CONTROL

PRICE LIST

MODEL RECOMMENDED CONTROL PRICE

KFC-CI-2T-300 KID-02 S £360

KFC-CI-2T-500 KID-02 S £377

KFC-CI-4T-300 KID-02 S £448

KFC-CI-4T-500 KID-02 S £457

ACCESSORIES FOR 2 PIPES UNITS

MODEL DESCRIPTION PRICE

KIT TUB FC CI-2TPipework kit for Cassette 600x600 units' valve

£32

KV3-FC 3/4 3-way valve 3/4 £26

KACT-O on/off Actuator £22

ACCESSORIES FOR 4 PIPES UNITS

MODEL DESCRIPTION PRICE

KIT TUB FC CI-4TPipework kit for Cassette 600x600 units' valve

£54

KV3-FC 1/2 3-way valve 1/2 (hot water) £26

KV3-FC 3/4 3-way valve 3/4 £26

KACT-O on/off Actuator £22

Go back to General Contents Go back to FANCOILS Index(Index)

261

WATER TERMINALUNITS

CASSETTES

CASSETTESTECHNICAL SPECIFICATIONS

MODEL KFC-CIS-2T-600 KFC-CIS-2T-750 KFC-CIS-2T-1200 KFC-CIS-2T-1500Cooling capacity (high)

TotalkW

5.7 7 10.39 12.9

Sensitive 3.92 4.82 7.15 8.88

Heating capacity kW 9.66 11.55 17.58 17.6

Power Input W 125 130 190 190

Airflow (high/medium/low) m3/h 1000/850/720 1250/1060/900 2000/1700/1440 2550/2170/1840

Indoor unit dimensions

Height mm 230 230 300 300

Width mm 840 840 840 840

Depth mm 840 840 840 840

Net weight of indoor unit Kg 25 25 30.5 35

Panel dimensions

Height mm 45 45 45 45

Width mm 950 950 950 950

Depth mm 950 950 950 950

Net weight (panel) Kg 6 6 6 6

Sound pressure (low) dB (A) 36 37 40 41

Hydraulic connections Ø Inches 3/4 3/4 3/4 3/4

Evaporator pressure drop Cooling kPa 23.8 25.2 44 40

Heating kPa 23.8 25.2 44 40

Water flow rate m3/h 0.98 1.2 1.79 2.22

MODEL KFC-CIS-4T-600 KFC-CIS-4T-950 KFC-CIS-4T-1500Cooling capacity (high)

TotalkW

5.1 6.7 10.58

Sensitive 3.51 4.61 7.28

Heating capacity kW 6.67 8.67 12.62

Power Input W 170 205 234

Airflow (high/medium/low) m3/h 1150/800/690 1720/1200/1030 2100/1470/1260

Indoor unit dimensions

Height mm 300 300 300

Width mm 840 840 840

Depth mm 840 840 840

Net weight of indoor unit Kg 35 35 38

Panel dimensions

Height mm 45 45 45

Width mm 950 950 950

Depth mm 950 950 950

Panel net weight Kg 6 6 6

Sound pressure (low) dB (A) 26 32 36

Hydraulic connections Ø Inches 3/4 3/4 3/4

Evaporator pressure drop Cooling kPa 15 22 38

Heating kPa 37 42 61

Water flow rate m3/h 0.88 1.15 1.82

2 PIPES

4 PIPES

*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb. Heating: water inlet/outlet temperature 70/60ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed. Same water flow as in Heating mode.

*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb. Heating: water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed. Same water flow as in Heating mode.

Go back to General Contents Go back to FANCOILS Index(Index)

262

Design and Install for you

FAN

COIL

SFA

NCO

ILS

CASSETTE 2 PIPES CASSETTE 4 PIPES

KID-02 S

*Kaysun controller

recommended

SAME PANEL AS VRF - ART FLUX 360º UNITS +COMPATIBLE WITH ALL THE KAYSUN CONTROLLERS RANGE +

The 360º panel Art Flux Cassette unit provides an even, fast air-conditioning controller that is far-reaching with no dead zones due to its additional motor, which allows the louvres to swing between 37 and 42º. The unit is so compact and light that it can be integrated into any space, including shallow ceilings, without sticking out.

• Condensation pump.

• Fresh air supply and air blow towards adjacent rooms.• Standard extended drainage pan.• Optional pipework kit.• Optional three-way valve.• Optional ON/OFF valve driver • XYE ON interface necessary for centralised/built-in

controllers (optional).

COMPATIBLE ACCESSORIES 2 PIPES COMPATIBLE ACCESSORIES 4 PIPES

KIT TUB FC CIS-2T KIT TUB FC CIS-4TKV3-FC 3/4 KV3-FC 1/2KV3-FC 3/4

KACT-0 KACT-0

GENERAL CHARACTERISTICS

PRICE CALCULATED BASED ON THE STANDARD OR RECOMMENDED CONTROL

If you want a different control, you should add to the € price for the set the price difference

between the standard or recommended control and the selected controlKAYSUN CONTROLLERS

INDIVIDUAL WIRELESS

INDIVIDUAL WIRED

CENTRALISED BMS AND SOFTWARE

KID-02 SKI-02.3 S

KC-01 S KC-02.1 H KCT-02.1 SR

KCC-64 I PSKCC-16KCCT-64 IKCC-64 WEB

K01-LONK01-KNX INTERFACE XYE ON

K02-MODBUSKAYNET CONTROL

K01-BACNET K01-WIFI

ELIGE TU CONTROL

CHOOSE YOUR CONTROL

ACCESSORIES FOR 2 PIPES UNITS

MODEL DESCRIPTION PRICE

KIT TUB FC CIS-2TPipework kit for valve Cassette unit with 2 pipes

£48

KV3-FC 3/4 3-way valve 3/4 £26

KACT-O on/off Actuator £22

ACCESSORIES FOR 4 PIPES UNITS

MODEL DESCRIPTION PRICE

KIT TUB FC CIS-4TPipework kit for 4-duct Cassette model valves

£64

KV3-FC 1/2 3-way valve 1/2 (hot water) £26

KV3-FC 3/4 3-way valve 3/4 £26

KACT-O on/off Actuator £22PRICE LIST

MODEL RECOMMENDED CONTROL PRICE

KFC-CIS-2T-600 KID-02 S £497

KFC-CIS-2T-750 KID-02 S £497

KFC-CIS-2T-1200 KID-02 S £565

KFC-CIS-2T-1500 KID-02 S £633

KFC-CIS-4T-600 KID-02 S £592

KFC-CIS-4T-950 KID-02 S £609

KFC-CIS-4T-1500 KID-02 S £672

Go back to General Contents Go back to FANCOILS Index(Index)

263

WATER TERMINALUNITS

DUCTS

DUCTS TECHNICAL SPECIFICATIONS

MODELKFC-PD-2T-200-1

KFC-PD-2T-300-1

KFC-PD-2T-400-1

KFC-PD-2T-600-1

KFC-PD-2T-800-1

Cooling capacity (high)Total

kW2.2 3.1 4 5.8 8.2

Sensitive 1.52 2.13 2.96 3.99 5.64

Heating capacity kW 3.5 5.3 6.8 9.8 13.6

Power Input W 49 64 75 114 154

Airflow (high/medium/low) m3/h 340/255/170 510/385/255 680/510/340 1020/765/510 1360/1020/680

Available static pressure Pa 30/50 30/50 30/50 30/50 30/50

Indoor unit dimensions

Height mm 241 241 241 241 241

Width mm 741 841 941 1161 1461

Depth mm 522 522 522 522 522

Net weight of indoor unit Kg 14.6 17 20.2 23 31.9

Sound pressure (low) dB (A) 31 32 33 35 36

Hydraulic connections Ø Inches 3/4 3/4 3/4 3/4 3/4

Evaporator pressure dropCooling kPa 14 26 18 36 39

Heating kPa 10.5 21.8 16.9 31.6 33.8

Water flow rate m3/h 0.38 0.53 0.69 1 1.41

MODELKFC-PD-4T-200-1

KFC-PD-4T-300-1

KFC-PD-4T-400-1

KFC-PD-4T-600-1

KFC-PD-4T-800-1

Cooling capacity (high)Total

kW2 2.7 3.6 5 6.8

Sensitive 1.38 1.86 2.48 3.44 4.68

Heating capacity kW 3 4 5.2 7.2 9.6

Power Input W 49 64 75 114 154

Airflow (high/medium/low) m3/h 340/255/170 510/385/255 680/510/340 1020/765/510 1360/1020/680

Available static pressure Pa 30/50 30/50 30/50 30/50 30/50

Indoor unit dimensions

Height mm 241 241 241 241 241

Width mm 741 841 941 1161 1461

Depth mm 522 522 522 522 522

Net weight of indoor unit Kg 15.1 17.5 20.7 23.5 32.4

Sound pressure (low) dB (A) 31 32 33 35 36

Hydraulic connections Ø Inches 3/4 3/4 3/4 3/4 3/4

Evaporator pressure dropCooling kPa 7.6 14.4 8.2 17.2 18.8

Heating kPa 6.8 12.5 23.5 40.7 20.7

Water flow rate m3/h 0.34 0.46 0.62 0.86 1.17

2 PIPES

4 PIPES

*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb. Heating: water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed. Same water flow as in Heating mode.

*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb. Heating: water inlet/outlet temperature 70/60ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed. Same water flow as in Heating mode.

Go back to General Contents Go back to FANCOILS Index(Index)

264

Design and Install for you

FAN

COIL

SFA

NCO

ILS

The duct type units include a tilted evaporator; it provides a wider exchange area and a compact and reduced height, which facilitates the unit installation in rooms where ceilings are just 241 mm high. Similar characteristics to direct expansion ducts, except that it does not have a condensate pump.

• Plate to support duct during suction/discharge.

• 3 pipe rows

• Removable filter without opening the duct unit case.

• Replaceable outlet panel (rear/lower).

• Fresh air supply.

• Available pressure 30/50 (Pa).

• Standard extended drainage pan on the left-hand side

• Optional left/right pipework kit

• Optional three-way valve.

• Optional on/off valve actuator.

DUCT 2 PIPES DUCT 4 PIPES

COMPATIBLE ACCESSORIES 2 PIPES COMPATIBLE ACCESSORIES 4 PIPES

KIT TUB FC PD-2T-1 KIT TUB FC PD-4T-1K01-FC-2T K01-FC-4TKC-FC-2T KC-FC-4TKV3-FC 3/4 KV3-FC 3/4KACT-0 KACT-0

COMPATIBLE WITH

COMPATIBLE WITH

Thermostat

Interface to control

+

GENERAL CHARACTERISTICS

COMPATIBLE WITH A WIDE RANGE OF CONTROLLER+

INDIVIDUAL WIRED

CENTRALISED BMS AND SOFTWARE

KC-01 S KC-02.1 H KCT-02.1 SR

KCC-64 I PSKCC-16KCCT-64 IKCC-64 WEB

K01-LONK01-KNX

K02-MODBUSKAYNET CONTROL

K01-BACNET K01-WIFI

KAYSUN CONTROLLERS

Compatible con

Compatible con

ELIGE TU CONTROL

CHOOSE YOUR CONTROL

ACCESSORIES FOR 2 PIPES UNITS

MODEL DESCRIPTION PRICE

KIT TUB FC PD-2T-1Plumbing kit for 2-duct low profile pipes valves

£59

KV3-FC 3/4 3-way valve 3/4 £26

KACT-O on/off Actuator £22

K02-FC-2T Interface to KAYSUN control 2 Pipes £154

KC-FC-2T Thermostat 2 pipes £34

ACCESSORIES FOR 4 PIPES UNITS

MODEL DESCRIPTION PRICE

KIT TUB FC PD-4T-1Plumbing kit for 4-duct low profile pipes valves

£104

KV3-FC 3/4 3-way valve 3/4 £26

KACT-O on/off Actuator £22

K02-FC-4T Interface to KAYSUN control 4 Pipes £160

KC-FC-4T Thermostat 4 pipes £34

PRICE LIST

MODEL PRICE KFC-PD-2T-200-1 £157

KFC-PD-2T-300-1 £173

KFC-PD-2T-400-1 £192

KFC-PD-2T-600-1 £221

KFC-PD-2T-800-1 £329

KFC-PD-4T-200-1 £182

KFC-PD-4T-300-1 £204

KFC-PD-4T-400-1 £222

KFC-PD-4T-600-1 £245

KFC-PD-4T-800-1 £351

Go back to General Contents Go back to FANCOILS Index(Index)

265

WATER TERMINALUNITS

CASSETTES

HIGH PRESSURE DUCTS 2 DUCTS

TECHNICAL SPECIFICATIONS

2 PIPES

MODEL KFC-PDH-2T-1000 KFC-PDH-2T-1400 KFC-PDH-2T-1800 KFC-PDH-2T-2200

Cooling capacity (high)Total

kW8.8 12 15.8 19.9

Sensitive 6.06 8.26 10.88 13.7

Heating capacity kW 13.2 17.9 23.8 30

Power Input W 350 350 800 950

Airflow (high/medium/low) m3/h 1700/1530/1380 2380/2120/1860 3060/2750/2450 3740/3360/2990

Available static pressure Pa 70 70 100 100

Indoor unit dimensions

Height mm 400 400 400 400

Width mm 946 946 1290 1290

Depth mm 816 816 809 809

Net weight of indoor unit Kg 52 54 76 76

Sound pressure (low) dB (A) 36 38 46 47

Hydraulic connections Ø Inches 3/4 3/4 3/4 3/4

Evaporator pressure drop kPa 24 36 90 130

kPa 25 34.2 85 121

Water flow rate m3/h 1.51 2.06 2.72 3.42

*Calculation conditions:Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb. Heating: water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan high speed. Information based on 70Pa of available pressure for KFC-PDH-2T-1000 and KFC-PDH-2T-1400. Information based on 100Pa of available pressure for KFC-PDH-2T-1800 and KFC-PDH-2T-2200. Same water flow as in Heating mode.

Go back to General Contents Go back to FANCOILS Index(Index)

266

Design and Install for you

FAN

COIL

SFA

NCO

ILS

These duct units dispose a high static pressure, the indoor unit is able to reach up to 100pa (1800 and 2200 models). This results in flexible ducts that make air-conditioning easier, more accurate and adaptable to every space, even in high ceilings rooms.

• 2 Pipes.

• Removable filter without opening the duct unit case.

• Plate to support duct during suction/discharge.

COMPATIBLE ACCESSORIES

K02-FC-2TKV3-FC 3/4 KACT-0 KC-FC-2T

GENERAL CHARACTERISTICS

INDIVIDUAL WIRED

CENTRALISED BMS AND SOFTWARE

KC-01 S KC-02.1 H KCT-02.1 SR

KCC-64 I PSKCC-16KCCT-64 IKCC-64 WEB

K01-LONK01-KNX

K02-MODBUSKAYNET CONTROL

K01-BACNET K01-WIFI

KAYSUN CONTROLLERS

COMPATIBLE WITH

COMPATIBLE WITHInterface to

control

Thermostat

+

COMPATIBLE WITH A WIDE RANGE OF CONTROLLERS +

1800 - 2200 MODELS 1000 - 1400 MODELS

Compatible with

Compatible with

ELIGE TU CONTROL

CHOOSE YOUR CONTROL

PRICE LIST

MODEL PRICE £

KFC-PDH-2T-1000 £421

KFC-PDH-2T-1400 £451

KFC-PDH-2T-1800 £625

KFC-PDH-2T-2200 £636

ACCESSORIES

MODEL DESCRIPTION PRICE £

KIT TUB FC PDH-2T Pipework kit for valve High Static Pressure Ducts £67

KIT TUB FC PDH-2T-1400 Pipework kit for valve High Static Pressure Ducts (model 1400) £67

KV3-FC 3/4 3-way valve 3/4 £26

KACT-O on/off Actuator £22

K02-FC-2T Interface to KAYSUN control 2 Pipes £154

KC-FC-2T Thermostat 2 pipes £34

Go back to General Contents Go back to FANCOILS Index(Index)

AQUATIX DOMESTIC HOT WATER RANGE

268

Design and Install for you

AQUATIXDOMESTIC HOT WATER RANGE

INTRODUCTION TO THE PRODUCT RANGE ......................................269

UNITSAquantia ................................................Monobloc .........................277

Aquantia ................................................Split ..................................281

Domestic hot water deposits ...............BS, G .................................285

Swimming pools ...................................KSWP ...............................289

Compak .................................................KHP ACS ..........................291

269

DOMESTIC HOT WATERRANGE

INTRODUCTION TO THE RANGE OF PRODUCTS

“THE MOST ECOLOGICAL

INNOVATION FOR YOUR HOME”

DOMESTIC HOT WATER RANGE AQUATIX

The Aquatix range reveals the vital energy of water and how to make the most of the resources in a single space.

Using a heat pump system, hot water with temperatures of up to 70ºC can be produced, putting the best qualities of this natural resource to work to heat the home with domestic hot water and underfloor heating.

The Aquatix heat pump is an alternative to the traditional hot water boiler, and saves a significant amount of energy, offering a broad variety of advantages for the home with maximum energy efficiency.

Aquatix equipment is designed for fast and simple installation, providing the best comfort, most advanced technology and maximum savings.

AQUANTIA

Discover Aquantia, the integrated system that provides heating, cooling and domestic hot water to your home. Enjoy maximum comfort all year round, with the great energy efficiency that characterises this system based on heat pumps.

The reversible heat pump is a system that obtains renewable energy from outside to heat or cool your home. It is the most efficient technology, absorbing more energy from the exterior than what Aquantia consumes.

As well as being more environmentally-friendly and energy efficient than other systems such as boilers, Aquantia can replace all of these systems or work together with them.

++

+

+

IT OFFERS HEATING, COOLING AND DOMESTIC HOT WATER: A YEAR-ROUND SOLUTION

ENERGY EFFICIENT (ECOLOGIC, ECONOMIC)

WIDE RANGE OF OPERATING TEMPERATURES

CAN FUNCTION WITH OTHER SOURCES OF ENERGY, SUCH AS SOLAR ENERGY AND BOILERS

Go back to General Contents Go back to AQUATIX Index(Index)

270

Design and Install for you

AQ

UA

TIX

DO

ME

STI

C H

OT

WA

TER

Heating:• Underfloor heating• Radiators• Fan Coils• Combination of the above

Cooling:• Fan Coils• Underfloor cooling• Combination of the above

Domestic Hot Water:• Accumulation deposits

Aquantia supplies hot and cold water to its underfloor heating, radiators, fan coils and water deposits. In addition to being a totally independent source of energy, it can also work with external sources (solar energy, boilers, etc.).

All components in the compact outdoor unit. A hydraulic system in an indoor unit and a heat pump in an outdoor unit.

THERE ARE TWO INSTALLATION OPTIONS, DEPENDING ON YOUR REQUIREMENTS:

MONOBLOC SPLIT

Go back to General Contents Go back to AQUATIX Index(Index)

271

DOMESTIC HOT WATERRANGE

INTRODUCTION TO THE RANGE OF PRODUCTS

• Touch control

• A wide choice of operating modes

• Priority manager

• Temperature setpoints

• Daily and weekly scheduling

• Option to enquire about working parameters, error codes,

service calls • Different levels of user• Test Run• Follow Me function (temperature sensor built into the control)• Modbus communication

AQUANTIA CONTROL

SOME FUNCTIONS

• Silence mode: Minimum noise levels guaranteed

• Fast domestic hot water mode

• Disinfection mode: Raises temperature to 70ºC

• Air purging

• Pre-heating of the environment

• Dehumidify the ground

• Choose from various operating modes (eco mode, holiday mode) and priority manager

2-way valve

Indoor unit

Zone 1 controlled by thermostat 1

Zone 2 controlled by thermostat 2

Domestic hot water deposit

Outdoor unit

Radiator

T

TTouch control

Thermostat 1

Thermostat 2

Under�oor heating

3-way valveM

M

Zone 1

Zone 2

Go back to General Contents Go back to AQUATIX Index(Index)

272

Design and Install for you

AQ

UA

TIX

DO

ME

STI

C H

OT

WA

TER

Brushless DC fan motor BLDC fan motor with stepless control helps to meet heating and cooling demands with low noise fan, super quiet operation, as well low power consumption.

The newly designed twin rotary DC inverter compressor with permanent magnet brings low working sound, wide working frequency and precession control. The upgraded DC motor power system of inverter model forms a full DC frequency conversion system and dramatically reduces power consumption by more than 30%.

DC inverter compressor

Fin-coil heat exchanger9.5 inner-threaded copper pipes optimize heat exchange eciency. Window ns enlarge the heat-exchanging area and decrease the air resistance. Blue coating increases the resistance against corrosive agents, enhance durability.

Doublerotary

Singlerotary

Double rotary compressor

Highly e�cient DC motor

- Resdesigned core motor

- High-density neodymium magnet

- Concentrated stator

- Wider operating frequency range

Minimal vibration

- Twin eccentric cams

- 2 balance weights

Highly stable moving parts

- Optimal material matching rollers and vanes

- Optimize compressor drive technolog

- Highly robust bearings

- Compact structure

Hydronic module Hydronic module with integrated DC water pump (monobloc) or separate DC water pump (bibloc)

Heat capacity of up to 80% at -7ºC, thanks to the size of the exchanger and compressor.

Support resistance It has support electric resistance for extreme outdoor temperatures

EASY INSTALLATION, MINIMAL MAINTENANCE

• Compact structure. The hydronic part can be installed indoors or outdoors.

• Easily connected to the pipe system of the house.

• Rapid access to the components of the system for inspection and maintenance

SMART, ADAPTABLE SYSTEM

• Select a work curve. Depending on the desired temperature, the system will automatically adapt when the temperature outside

changes.

WIDE RANGE OF OPERATING TEMPERATURES

60°C

40°C

Domestic hot water

25°C

5°C

Cooling

60°C

25°C

Heating

10°C

5°C

20°C

30°C

40°C

50°C

60°C

70°C

Output water temperature

46°C

-5°C

Cooling

35°C

-20°C

Heating 43°C

-20°C

Domestic hot water

-20°C

-10°C

0°C

10°C

20°C

30°C

40°C

50°C

60°C

Outdoor ambient temperature

Go back to General Contents Go back to AQUATIX Index(Index)

273

DOMESTIC HOT WATERRANGE

INTRODUCTION TO THE RANGE OF PRODUCTS

CHARACTERISTICS

DC INVERTER

The traditional motors used in heat pumping systems waste energy, as they always work

at full load.

The technology used in the KAYSUN UK DC Inverter reduces energy consumption by up to

30%, since it adapts energy consumption to the actual load of the system.

WATER AT CONSTANT TEMPERATURE

The rotation speed of the compressor is controlled with great precision and according to

demand using DC Inverter technology. The temperature setpoint for the water remains

stable, providing the user with greater comfort.

FEWER STOPS AND STARTS

The technology of the inverter reduces the frequency of stop-start cycles. This extends

the life of components and minimises noise.

QUIET

Most of the time it is in operation, the energy requirements of the home are less than full

capacity.

As well as a silence mode, due to the adjustable frequency of the compressor the

equipment for the most part operates at less than full capacity, reducing noise levels.

BOTH AQUANTIA (MONOBLOC AND SPLIT) HAVE AN ERP ENERGY EFFICIENCY RATING OF A++

Go back to General Contents Go back to AQUATIX Index(Index)

274

Design and Install for you

AQ

UA

TIX

DO

ME

STI

C H

OT

WA

TER

AQUANTIA MONOBLOC

AQUANTIA SPLIT

POWER RANGE

4 5 6 7 8 12 14 16Heating capacity (kW)

KHP-MO 7 DVN KHP-MO 14 DVN

KHP-MO 14 DTN

KHP-MO 5 DVN KHP-MO 12 DVN

KHP-MO 12 DTN

KHP-MO 16 DVN

KHP-MO 16 DTN

SINGLE-PHASE

THREE-PHASE

4 5 6 7 8 12 14 16Heating capacity (kW)

KHP-BI 6 DVN KHP-BI 14 DVN

KHP-BI 14 DTN

KHP-BI 4 DVN KHP-BI 12 DVNKHP-BI 8 DVN

KHP-BI 12 DTN

KHP-BI 16 DVN

KHP-BI 16 DTN

SINGLE-PHASE

THREE-PHASE

SWIMMING POOLS

Thanks to these units, users will be able to heat, cool their swimming pool water and enjoy with their families while they swim without having to worry about water temperature.

KAYSUN UK introduces four units of 6, 8, 12 and 14 kW that can adapt to the needs of any standard household swimming pool. The KSWPs are small and compact, so can be installed without being seen.

Thanks to the built-in titanium pipe in pipe exchanger, these units can work with all kinds of water without considering its source or treatment (chlorine, salt electrolysis, bromine, ozone, among others). If compared to other materials, it provides the exchanger with longer durability.

Go back to General Contents Go back to AQUATIX Index(Index)

275

DOMESTIC HOT WATERRANGE

INTRODUCTION TO THE RANGE OF PRODUCTS

COMPAK

COMPAK KHP

This compact unit, fitted with evaporator, condenser and built-in tank, is an optional solution to be considered for producing domestic hot water or underfloor heating. This option is easy to integrate into many spaces because it eliminates the need for many units, as everything is built into the same unit.

This unit's condenser is built around the water tank, keeping the refrigerant and domestic hot water from coming into direct contact.

COMPAK KHP 35 300 ACS 1

The new 3 kW COMPAK KHP unit with vitrified enamel, which allows water to be discharged at temperatures close to 70ºC.

This compact unit, equipped with a centrifugal fan and a static pressure of 25 Pa, allows to direct the air through a duct of up to 10 metres in length.

COMPAK KHP 35 300 ACS 1

water

water tank

liquid tank

compressorfan / evaporator

Thermostatic expansion valve

magnesium anode

condenser

auxiliary heater

AIR INLETAIR INLET

COMPAK KHP 15 190 ACS 1

The KAYSUN UK COMPAK KHP 15 190 ACS1 is an ideal option for domestic use. With a storage capacity of 190 litres and a power input of 500W, it is an interesting option for producing domestic hot water.

LITRES 250 300 350200150

COMPAK KHP 15 190 ACS 1

COMPAK KHP 35 ACS 1

Go back to General Contents Go back to AQUATIX Index(Index)

276

Design and Install for you

UNITS

TECHNICAL SPECIFICATIONS

277

DOMESTIC HOT WATERRANGE

INTEGRATED SYSTEM

AQUANTIA MONOBLOCTECHNICAL SPECIFICATIONS

MODEL KHP-MO 5 DVN KHP-MO 7 DVNPower Supply V/ph/Hz 220-240/1/50 220-240/1/50

Heating capacity1kW 4.64 6.55

kCal/h 3990 5632

Heating input1 kW 0.97 1.45

COP1 W/W 4.79 4.52

Heating capacity2kW 4.72 6.72

kCal/h 4058 5778

Heating input2 kW 1.44 2.01

COP2 W/W 3.29 3.35

Cooling capacity3kW 4.77 6.63

kCal/h 4101 5701

Cooling input3 kW 1.01 1.46

EER3 W/W 4.72 4.53

Cooling capacity4kW 4.65 6.69

kCal/h 3998 5752

Cooling input4 kW 1.56 2.48

EER4 W/W 2.98 2.70

Energy classWater outlet 35ºC A++ A++

Water outlet 55ºC A+ A+

Compressor type Double Rotary DC Inverter

Number of outdoor ventilators 1 1

Outdoor airflow m3/h 3050 3050

Exchanger type (water) Plates

Loss of load from water pump m 6 6

Refrigerant oil type R-410 R-410

Volume of preload Kg 2.4 2.4

Volume of expansion tank L 2 2

Regulation Electronic expansion valve

Standard backup resistor kW - -

Optional backup resistor kW 3 3

Heating sound pressure level5 dB (A) 62 62

Cooling sound pressure level5 dB (A) 63 63

DimensionsHeight mm 945 945

Width mm 1210 1210

Depth mm 402 402

Weight Kg 99 99

Pipe connections diameter Inches 1" female BSP 1" female BSP

Safety valve Mpa 0.3 0.3

Total water volume L 2 2

Outdoor ambient temperatureHeating ºC -20~35

Cooling ºC -5~46

DHW ºC -20~43

Output water temperatureHeating ºC 25~60

Cooling ºC 5~25

DHW ºC 40~60

Rated capacities based on the following conditions:1 Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 30/35ºC2 Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 40/45ºC3 Air in evaporator at 35ºC, water in input/output evaporator 23/18ºC4 Air in condenser at 35ºC, water in input/output evaporator 12/7ºC5 At 1 metre without obstacles, side of ventilator (sound pressure)

Go back to General Contents Go back to AQUATIX Index(Index)

278

Design and Install for you

AQ

UA

TIX

DO

ME

STI

C H

OT

WA

TER

KHP-MO 12 DVN KHP-MO 12 DTN KHP-MO 14 DVN220-240/1/50 380-415/3/50 220-240/1/50

12.13 12.33 14.75

10430 10602 12683

2.63 2.72 3.42

4.61 4.54 4.31

12.57 11.97 14.06

10808 10292 12089

3.86 3.68 4.45

3.26 3.25 3.16

12.23 12.68 14.17

10516 109.03 12184

2.60 2.72 3.18

4.70 4.67 4.46

12.21 12.27 12.99

10499 10550 11169

4.14 4.22 4.50

2.95 2.91 2.89

A++ A++ A++

A+ A+ A++

Double Rotary DC Inverter

2 2 2

6150 7000 6150

Plates

7.5 7.5 7.5

R-410 R-410 R-410

3.6 3.6 3.6

5 5 5

Electronic expansion valve

3 4.5 3

- - -

67 67 71

66 66 70

1414 1408 1414

1405 1397 1405

405 400 405

162 174 162

1-1/4" female BSP 1-1/4" female BSP 1-1/4" female BSP

0.3 0.3 0.3

5.5 5.5 5.5

-20~35

-5~46

-20~43

25~60

5~25

40~60

Go back to General Contents Go back to AQUATIX Index(Index)

279

DOMESTIC HOT WATERRANGE

INTEGRATED SYSTEM

AQUANTIA MONOBLOC

TECHNICAL SPECIFICATIONS

MODEL KHP-MO 14 DTN KHP-MO 16 DVN KHP-MO 16 DTNPower Supply V/ph/Hz 380-415/3/50 220-240/1/50 380-415/3/50

Heating capacity1kW 14.08 16.38 16.3

kCal/h 12107 14084 14015

Heating input1 kW 3.24 4.02 3.88

COP1 W/W 4.35 4.08 4.19

Heating capacity2kW 14.09 16.13 16.08

kCal/h 12115 13869 13826

Heating input2 kW 4.43 5.22 5.24

COP2 W/W 3.18 3.09 3.07

Cooling capacity3kW 14.05 14.93 15.13

kCal/h 12081 12837 13009

Cooling input3 kW 3.24 3.64 3.75

EER3 W/W 4.34 4.10 4.03

Cooling capacity4kW 13.83 13.75 15.27

kCal/h 11892 11823 13130

Cooling input4 kW 5.12 5.13 6.42

EER4 W/W 2.70 2.68 2.38

Energy classWater outlet 35ºC A++ A++ A++

Water outlet 55ºC A++ A+ A++

Compressor type Double Rotary DC Inverter

Number of outdoor ventilators 2 2 2

Outdoor airflow m3/h 7000 6150 7000

Exchanger type (water) Plates

Loss of load from water pump m 7.5 7.5 7.5

Refrigerant oil type R-410 R-410 R-410

Volume of preload Kg 3.6 3.6 3.6

Volume of expansion tank L 5 5 5

Regulation Electronic expansion valve

Standard backup resistor kW 4.5 3 4.5

Optional backup resistor kW - - -

Heating sound pressure level5 dB (A) 71 72 72

Cooling sound pressure level5 dB (A) 70 71 71

DimensionsHeight mm 1408 1414 1408

Width mm 1397 1405 1397

Depth mm 400 405 400

Weight Kg 174 162 174

Pipe connections diameter Inches 1-1/4" female BSP 1-1/4" female BSP 1-1/4" female BSP

Safety valve Mpa 0.3 0.3 0.3

Total water volume L 5.5 5.5 5.5

Outdoor ambient temperatureHeating ºC -20~35

Cooling ºC -5~46

DHW ºC -20~43

Output water temperatureHeating ºC 25~60

Cooling ºC 5~25

DHW ºC 40~60

Rated capacities based on the following conditions:1 Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 30/35ºC2 Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 40/45ºC3 Air in evaporator at 35ºC, water in input/output evaporator 23/18ºC4 Air in condenser at 35ºC, water in input/output evaporator 12/7ºC5 At 1 metre without obstacles, side of ventilator (sound pressure)

Go back to General Contents Go back to AQUATIX Index(Index)

280

Design and Install for you

AQ

UA

TIX

DO

ME

STI

C H

OT

WA

TER

An integrated system that provides heating, cooling and domestic hot water to your home. It can generate energy totally independently using its heat pump, or draw on other sources (solar energy, boilers, etc.) already installed.

• DC ventilator and compressor.

• Heating, cooling and domestic hot water from a single system.

• It can operate on its own or draw on other energy sources already installed.

• All components in a compact outdoor unit.

GENERAL CHARACTERISTICS HEATING

COOLING

DOMESTIC HOT WATER

TOUCH CONTROL

SMART, ADAPTABLE SYSTEM

EASY INSTALLATION, MINIMAL MAINTENANCE

WIDE RANGE OF OPERATING TEMPERATURES

UNDERFLOOR HEATING+

FANCOILS+

ACCUMULATION DEPOSITS+

RADIATORS+

COLD FLOOR+

FANCOILS+

COMBINATION OF THE ABOVE+

COMBINATION OF THE ABOVE+

AQUANTIA MONOBLOC

PRICE LIST

MODEL POWER SUPPLY CAPACITY HEATING (KW) CONTROL PRICE

KHP-MO 5 DVN 220/1/50 5 KCTAQ-01 £2,791

KHP-MO 7 DVN 220/1/50 7 KCTAQ-01 £3,067

KHP-MO 12 DVN 220/1/50 12 KCTAQ-01 £5,101

KHP-MO 12 DTN 380/3/50 12 KCTAQ-01 £5,186

KHP-MO 14 DVN 220/1/50 14 KCTAQ-01 £5,420

KHP-MO 14 DTN 380/3/50 14 KCTAQ-01 £5,531

KHP-MO 16 DVN 220/1/50 16 KCTAQ-01 £5,716

KHP-MO 16 DTN 380/3/50 16 KCTAQ-01 £5,901

ACCESSORY* PRICE

KIT R 8 VN optional backup resistor kit £422

*For KHP-MO 5 DVN and KHP-MO 7 DVN

Go back to General Contents Go back to AQUATIX Index(Index)

281

DOMESTIC HOT WATERRANGE

INTEGRATED SYSTEM

AQUANTIA SPLIT OUTDOOR UNIT

TECHNICAL SPECIFICATIONS

MODEL KHP-BI 4 DVN KHP-BI 6 DVN KHP-BI 8 DVNPower Supply V/ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50

Heating capacity1kW 4.10 6.10 8.00

kCal/h 3525 5245 6879

Heating input1 kW 0.82 1.29 1.73

COP1 W/W 5.00 4.73 4.62

Heating capacity2kW 4.01 5.96 7.34

kCal/h 3448 5125 6311

Heating input2 kW 1.13 1.68 2.13

COP2 W/W 3.55 3.55 3.45

Cooling capacity3kW 4.10 6.10 8.00

kCal/h 3525 5245 6879

Cooling input3 kW 0.79 1.31 1.78

EER3 W/W 5.19 4.66 4.49

Cooling capacity4kW 4.12 6.15 6.44

kCal/h 3543 5288 5537

Cooling input4 kW 1.30 2.08 2.24

EER4 W/W 3.17 2.96 2.88

Energy classWater outlet 35ºC A++ A++ A++

Water outlet 55ºC A+ A+ A+

Compressor type Double Rotary DC Inverter

Number of outdoor ventilators 1 1 1

Outdoor airflow m3/h 3180 3180 5120

Refrigerant oil type R-410 R-410 R-410

Volume of preload Kg 2.5 2.8 3.9

Heating sound pressure level5 dB (A) 62 62 64

Cooling sound pressure level5 dB (A) 62 62 64

DimensionsHeight mm 860 860 965

Width mm 960 960 1075

Depth mm 380 380 395

Weight Kg 60 76 99

Pipe connections

Liquid pipe diameter mm ø9.5 ø9.5 ø9.5

Gas pipe diameter mm ø15.9 ø15.9 ø15.9

Pipe length (min./max.)

m 2/20 2/20 2/30

Height difference, upper outdoor unit

m 10 10 20

Height difference, lower outdoor unit

m 8 8 15

Outdoor ambient temperature

Heating ºC -20~35

Cooling ºC -5~46

DHW ºC -20~43

Rated capacities based on the following conditions:1 Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 30/35ºC2 Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 40/45ºC3 Air in evaporator at 35ºC, water in input/output evaporator 23/18ºC4 Air in condenser at 35ºC, water in input/output evaporator 12/7ºC5 At 1 metre without obstacles, side of ventilator (sound pressure)

Go back to General Contents Go back to AQUATIX Index(Index)

282

Design and Install for you

AQ

UA

TIX

DO

ME

STI

C H

OT

WA

TER

KHP-BI 12 DVN KHP-BI 12 DTN KHP-BI 14 DVN KHP-BI 14 DTN KHP-BI 16 DVN KHP-BI 16 DTN220-240/1/50 380-415/3/50 220-240/1/50 380-415/3/50 220-240/1/50 380-415/3/50

12.10 12.10 14.00 14.00 15.50 15.50

10404 10404 12038 12038 13328 13328

2.74 2.68 3.39 3.26 3.82 3.79

4.42 4.51 4.13 4.29 4.06 4.09

11.85 11.97 14.05 13.93 16.05 15.48

10189 10292 12081 119.78 13801 13310

3.48 3.50 4.41 4.21 5.03 4.87

3.41 3.42 3.19 3.31 3.19 3.18

11.80 12.10 13.00 13.00 14.00 14.00

10146 10404 11178 11178 12038 12038

2.65 2.82 2.65 3.21 3.63 3.68

4.45 4.29 4.02 4.05 3.87 3.8

11.02 11.70 12.49 12.53 12.85 12.91

9475 10060 10739 10774 11049 11101

4.17 4.65 5.07 5.21 5.39 5.52

2.64 2.52 2.46 2.40 2.38 2.34

A++ A++ A++ A++ A++ A++

A+ A+ A+ A+ A+ A+

Double Rotary DC Inverter

2 2 2 2 2 2

6500 6500 6500 6500 6500 6500

R-410 R-410 R-410 R-410 R-410 R-410

3.9 4.2 3.9 4.2 3.9 4.2

66 66 69 69 71 71

66 66 69 69 71 71

1327 1327 1327 1327 1327 1327

900 900 900 900 900 900

400 400 400 400 400 400

99 115 99 115 99 115

ø9.5 ø9.5 ø9.5 ø9.5 ø9.5 ø9.5

ø15.9 ø15.9 ø15.9 ø15.9 ø15.9 ø15.9

2/50 2/50 2/50 2/50 2/50 2/50

30 30 30 30 30 30

25 25 25 25 25 25

-20~35

-5~46

-20~43

Go back to General Contents Go back to AQUATIX Index(Index)

283

DOMESTIC HOT WATERRANGE

INTEGRATED SYSTEM

TECHNICAL SPECIFICATIONS

MODEL KIT KHP BI 8 VN KIT KHP BI 16 VN KIT KHP BI 16 TNPower Supply V/ph/Hz 220-240/1/50 220-240/1/50 380-415/3/50

Water outlet temperature ranges

Heating (low) ºC 25~55, default 35

Heating (high) ºC 35~60, default 45

Cooling (low) ºC 7~25, default 7

Cooling (high) ºC 18~25, default 18

DHW ºC 40~60, default 45

Dimensions

Height mm 865

Width mm 400

Depth mm 427

Weight Kg 43 54 54

Pipe connections diameter mm DN25

Safety valve Mpa 0.3 0.3 0.3

Total water volume L 4.7 5 5

Volume of expansion tank L 3 3 3

Exchanger type Plates

Loss of load from water pump m 6 7.5 7.5

Refrigerant circuit diameter (liquid) mm ø9.5 ø9.5 ø9.5

Refrigerant circuit diameter (gas) mm ø15.9 ø15.9 ø15.9

Standard backup resistor kW 3.0 3.0 4.5

AQUANTIA SPLIT INDOOR UNIT

Go back to General Contents Go back to AQUATIX Index(Index)

284

Design and Install for you

AQ

UA

TIX

DO

ME

STI

C H

OT

WA

TER

An integrated system that provides heating, cooling and domestic hot water to your home. It can generate energy totally independently using its heat pump, or draw on other sources (solar energy, boilers, etc.) already installed.

• DC ventilator and compressor.• Heating, cooling and domestic hot water from a single system.• It can operate on its own or draw on other energy sources

already installed.

A hydraulic system in an indoor unit and a heat pump in an outdoor unit.

GENERAL CHARACTERISTICS HEATING

COOLING

DOMESTIC HOT WATER

TOUCH CONTROL

SMART, ADAPTABLE SYSTEM

EASY INSTALLATION, MINIMAL MAINTENANCE

WIDE RANGE OF OPERATING TEMPERATURES

UNDERFLOOR HEATING+

FANCOILS+

ACCUMULATION DEPOSITS+

RADIATORS+

COLD FLOOR+

FANCOILS+

+

COMBINATION OF THE ABOVE

COMBINATION OF THE ABOVE

+

AQUANTIA SPLIT

PRICE LIST

MODEL POWER SUPPLY CAPACITY HEATING (KW) CONTROL UNIT

OUTDOOR PRICE

KHP-BI 4 DVN 220/1/50 4 KCTAQ-01 KIT KHP BI 8 VN £1,149

KHP-BI 6 DVN 220/1/50 6 KCTAQ-01 KIT KHP BI 8 VN £1,203

KHP-BI 8 DVN 220/1/50 8 KCTAQ-01 KIT KHP BI 8 VN £1,558

KHP-BI 12 DVN 220/1/50 12 KCTAQ-01 KIT KHP BI 16 VN £2,291

KHP-BI 12 DTN 380/3/50 12 KCTAQ-01 KIT KHP BI 16 TN £2,396

KHP-BI 14 DVN 220/1/50 14 KCTAQ-01 KIT KHP BI 16 VN £2,790

KHP-BI 14 DTN 380/3/50 14 KCTAQ-01 KIT KHP BI 16 TN £2,889

KHP-BI 16 DVN 220/1/50 16 KCTAQ-01 KIT KHP BI 16 VN £3,110

KHP-BI 16 DTN 380/3/50 16 KCTAQ-01 KIT KHP BI 16 TN £3,332

Go back to General Contents Go back to AQUATIX Index(Index)

285

DOMESTIC HOT WATERRANGE

DEPOSITS FOR DOMESTIC HOT WATER

DEPOSITS FOR DOMESTIC HOT WATER

TECHNICAL SPECIFICATIONS

MODEL BSX160 BSX200 BSX300Capacity L. 160 200 300

Heat Exchanger type Heat coil Heat coil Heat coil

Dimensions

Height mm 1124 1315 1209

Diameter mm Ø 590 Ø 590 Ø 700

Floor including front cover mm 630 630 740

Net weight Kg 104 123 136

Upper heat coil entrance diameter Inches - - -

Upper heat coil exit diameter Inches - - -

Area of upper heat coil m2 - - -

Lower heat coil entrance diameter Inches 1” 1” 1”

Lower heat coil exit diameter Inches 1” 1” 1”

Area of lower heat coil m2 1.48 1.70 2.20

Cold water inlet Inches 3/4” 3/4” 1”

Heat water outlet Inches 3/4” 3/4” 1”

Circulation Inches 3/4” 3/4” 1”

Cleaning cap mm 280 280 280

Tank protective cap material Coat of enamel

Interior cover Steel

Exterior cover Galvanized steel with electrostatic coating with powdered paint.

Casing colour White

Plugs and exterior cap material Black coloured plastic

Insulating material and thickness mm Injected polyurethane foam, 50 mm

Input of sensors for the automatic control of the unit Ø / depth (mm) 3 units, Ø13 x 100

Operating pressure bar 10 10 10

Test pressure bar 13 13 13

Temperature indicator Analogue thermometer

Anti-corrosive protection Magnesium anode rod and tester

Go back to General Contents Go back to AQUATIX Index(Index)

286

Design and Install for you

AQ

UA

TIX

DO

ME

STI

C H

OT

WA

TER

MODEL BS500 KAYSUN G-751Capacity L. 500 750

Heat Exchanger type Heat coil Heat coil

Dimensions

Height mm 1800 2010

Diameter mm Ø 750 Ø 940

Floor including front cover mm 790 1000

Net weight Kg 192 285

Upper heat coil entrance diameter Inches - -

Upper heat coil exit diameter Inches - -

Area of upper heat coil m2 - -

Lower heat coil entrance diameter Inches 1 1/4" 1 1/4"

Lower heat coil exit diameter Inches 1 1/4" 1 1/4"

Area of lower heat coil m2 2.45 4.87

Cold water inlet Inches 1" 1 1/4"

Heat water outlet Inches 1" 1 1/4"

Circulation Inches 1" 1 1/4"

Cleaning cap mm 280 DN200

Tank protective cap material Coat of enamel Low carbon steel

Interior cover Steel Double coat of vitrified Enamel

Exterior cover Galvanised steel with electrostatic coating with powdered paint Soft PVC coating

Casing colour White Yellow

Plugs and exterior cap material Black coloured plastic

Insulating material and thickness mm Injected polyurethane foam, 50 mm

Input of sensors for the automatic control of the unit Ø / depth (mm) 3 units, Ø13 x 100 1 units 1/2”

Operating pressure bar 10 9

Test pressure bar 13 18

Temperature indicator Analogue thermometer

Anti-corrosive protection Magnesium anode rod and tester

Go back to General Contents Go back to AQUATIX Index(Index)

287

DOMESTIC HOT WATERRANGE

DEPOSITS FOR DOMESTIC HOT WATER

DEPOSITS FOR DOMESTIC HOT WATER

TECHNICAL SPECIFICATIONS

MODEL KAYSUN G-1001 KAYSUN G-1002 KAYSUN G-1501 KAYSUN G-2001Capacity L. 1000 1000 1500 2000

Heat Exchanger type Heat coil Double heat coil Heat coil Heat coil

Dimensions

Height mm 2015 2015 2050 2060

Diameter mm Ø 1000 Ø 1000 Ø 1200 Ø 1350

Floor including front cover mm 1065 1065 1300 1450

Net weight Kg 340 350 520 570

Upper heat coil entrance diameter Inches - 1 1/4" - -

Upper heat coil exit diameter Inches - 1 1/4" - -

Area of upper heat coil m2 - 1.8 - -

Lower heat coil entrance diameter Inches 1 1/4" 1 1/4" 1 1/4" 1 1/4"

Lower heat coil exit diameter Inches 1 1/4" 1 1/4" 1 1/4" 1 1/4"

Area of lower heat coil m2 5.06 3.86 6.83 7.52

Cold water inlet Inches 1 1/4" 1 1/4" 1 1/4" 1 1/4"

Heat water outlet Inches 1 1/4" 1 1/4" 1 1/4" 1 1/4"

Circulation Inches 1 1/4" 1 1/4" 1 1/4" 1 1/4"

Cleaning cap mm DN200 DN200 DN400 DN400

Tank protective cap material Low carbon steel

Interior cover Double coat of vitrified Enamel

Exterior cover Soft PVC coating

Casing colour Yellow

Plugs and exterior cap material Black coloured plastic

Insulating material and thickness mm Insulating foam, 75 mm

Input of sensors for the automatic control of the unit Inches

1 unit 1/2”

2 units 1/2" each

1 unit 1/2”

2 units 1/2" each

Operating pressure bar 9 9 9 9

Test pressure bar 18 18 18 18

Temperature indicator Analogue thermometer

Anti-corrosive protection Magnesium anode rod and tester

Go back to General Contents Go back to AQUATIX Index(Index)

288

Design and Install for you

AQ

UA

TIX

DO

ME

STI

C H

OT

WA

TER

The Aquatix range is fitted with tanks for domestic hot water and underfloor heating. These tanks are an ideal complement for Aquantia systems.

When there are two heat coils available, the upper heat coil is connected to a domestic hot water heat pump, while the other heat coil can be used for hot water from a solar thermal system or a conventional boiler.

• 1-2 heat coils available inside the unit.

• Optional 2kW backup resistor with thermostat.

• Magnesium protection anode to avoid internal corrosion of the tank. Malfunction test included.

• Analogue thermometer to know the temperature of the upper side of the tank.

DEPOSIT G (1 HEAT COIL)BS AND BSX DEPOSIT DEPOSIT G (2 HEAT COILS)

* Connected to upper heat coil

GENERAL CHARACTERISTICS

PRICE LIST

MODEL 1 HEAT COIL CAPACITY IN LITRES PRICE

BSX160 160 £757

BSX200 200 £813

BSX300 300 £973

BS500 500 £1,034

G-751 750 £1,753

G-1001 1000 £2,088

G-1501 1500 £2,781

G-2001 2000 £3,012

MODEL 2 HEAT COILS CAPACITY IN LITRES PRICE

G-1002 1000 £2,347

ACCESSORY PRICE

RT1, resistor of 2 kW with thermostat for models G- £46

RT2, resistor of 2 kW with thermostat for models B- £52

Go back to General Contents Go back to AQUATIX Index(Index)

289

DOMESTIC HOT WATERRANGE

UNITS FOR SWIMMING POOLS

MODEL KSWP-60HN KSWP-80 HN KSWP-120 HN KSWP-140 HNPower Supply V/ f/ Hz 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50

Outdoortemperature

Heating mode ºC -7 ~ 38 -7 ~ 38 -7 ~ 38 -7 ~ 38

Cooling mode ºC 15 ~ 43 15 ~ 43 15 ~ 43 15 ~ 43

Water outlettemperature

Heating mode ºC Defect 28, 20 ~ 35 Defect 28, 20 ~ 35 Defect 28, 20 ~ 35 Defect 28, 20 ~ 35

Cooling mode ºC Defect 28, 10 ~ 30 Defect 28, 10 ~ 30 Defect 28, 10 ~ 30 Defect 28, 10 ~ 30

Heating mode

Capacity kW 6 8 11.7 13.6

Input power kW 1.15 1.16 2.35 2.55

Cop - 5.22 5.27 4.98 5.33

Cooling mode

Capacity kW 4 5.8 8.25 10.35

Input power kW 1.25 1.5 2.5 2.9

EER - 3.2 3.87 3.3 3.57

Sound Pressure Level dB (A) 58 58 58 58

Heat exchanger type Titanium piped exchanger

Volume of R410a refrigerant Kg 1 1.25 1.6 1.85

Maximum volume swimming pool m3 Conduct prior thermal study

Water flow rate m3/h 2.6 3.5 5 5.8

Water flow rate (max./min.) m3/h 20/0.8 20/0.8 20/1.5 20/1.5

Dimensions

Width mm 1015 1015 1050 1050

Height mm 705 705 855 855

Depth mm 385 385 315 315

Net weight Kg 58.5 66 75 75

Hydraulicconnections

Input mm (inch) PVC 50 (2”) PVC 50 (2”) PVC 50 (2”) PVC 50 (2”)

Output Input PVC 50 (2”) PVC 50 (2”) PVC 50 (2”) PVC 50 (2”)

Drain mm (inch) PVC 25 (1”) PVC 25 (1”) PVC 25 (1”) PVC 25 (1”)

Max./min. pressure Water MPa 0.4/0.15 0.4/0.15 0.4/0.15 0.4/0.15

Heat exchanger pressure drop kPa 12 12 15 18

SWIMMING POOLS

TECHNICAL SPECIFICATIONS

Calculation conditions: Heating: outdoor temperature 24/19ºC (DB/WB), water inlet temperature 27ºC, water outlet temperature 29ºC. Cooling: outdoor temperature 35/24ºC (DB/WB), water inlet temperature 27ºC. Defined water flow.

PRICE LIST

MODEL PRICE

KSWP-60HN £1,016

KSWP-80HN £1,078

KSWP-120HN £1,262

KSWP-140HN £1,355

Go back to General Contents Go back to AQUATIX Index(Index)

290

Design and Install for you

AQ

UA

TIX

DO

ME

STI

C H

OT

WA

TER

KAYSUN UK has added new household units for swimming pools to the Aquatix range. This new family consists of four units of 6, 8, 12 and 14kW.

Their wide working range, from -7ºC to 43ºC, allows them working day, night, and under any weather condition, which turns them into highly versatile products.

These units can be used to heat or cool swimming pool water to provide users with greater comfort.These units have a titanium exchanger that provides them with longer durability and allows them working without considering its source or treatment of the water (the treatment of chlorine, salt electrolysis, bromine, ozone, among others).

The slim design and reduced maintenance space of these new units allow users to install them anywhere at your home without inconveniences.

They are fitted with a simple controller that helps users to control the unit easily and accurately. The controller operating range is 1 metre.

GENERAL CHARACTERISTICS

The following diagram shows a typical installation of one of these units with all the necessary elements to carry out the hydraulic connection to the swimming pool.

Go back to General Contents Go back to AQUATIX Index(Index)

291

DOMESTIC HOT WATERRANGE

ACCUMULATORS

MODEL COMPAK KHP 15 190 ACS 1 COMPAK KHP 35 300 ACS 1Power Supply V/ph/Hz 220-240/1/50 220-240/1/50

Operation mode Economy Economy

Room temperature ºC -7~43 -7~43

Heating capacitykW 1.45 3

kCal/h 1.25 2.58

Nominal input kW 0.38 0.80

Cop 3.8 3.76

Rated current A 2.3 4.1

Water flow rate m3/h 0.043 0.086

Electrical resistor kW 3 3

Compressor type Rotary Rotary

R134a refrigerant volume Kg 1 1.2

Safeguards High pressure, overload, electrical leakage

Evaporator material Hydrophilic aluminium fin, inner-grooved copper tube

Water pipeline

Output water temper-ature ºC

Default 60ºC (Adjustable: 38ºC-70ºC)

Default 55ºC (Adjustable: 38ºC-65ºC)

Heat exchanger Copper tubing around the tank

Water inlet mm DN 20 DN 20

Water outlet mm DN 20 DN 20

Drainage pipe mm DN 20 DN 20

Safety valve mm DN 20 DN 20

Max. Pressure MPa 1 1

Dimensions mm Ø568x1760 Ø650x1920

Tank volume l 190 300

Net weight Kg 107 145.5

Sound Pressure Level dB (A) 41.2 45

Air intake and outlet

Diameter mm ø160 ø190

Static Pressure Pa 25 25

Max. Length m - 10

Outdoor airflow m3/h 270/230/182 414/355/312

Anti-legionella function Yes Yes

COMPAK

TECHNICAL SPECIFICATIONS

Go back to General Contents Go back to AQUATIX Index(Index)

292

Design and Install for you

AQ

UA

TIX

DO

ME

STI

C H

OT

WA

TER

COMPAK KHP 35 300 ACS 1

Domestic hot water storage or underfloor heating using heat pump technology. Provides water temperatures of up to 70ºC. It is fitted with a condenser located around the tank to avoid contact between refrigerant and sanitary hot water. It also includes a magnesium protection anode to avoid internal corrosion of the tank.

• Compact design and easy installation.

• LCD screen control display.

• They must be protected against solar radiation

• Built-in relief valve.

COMPAK KHP 15 190 ACS 1

GENERAL CHARACTERISTICS

ECONOMY: only the heating pump operates +ELECTRICAL RESISTOR for heating+HYBRID: use of the heat pump + resistor +MAGESIUM ANODE in all models+

OPERATION MODE

PRICE LIST

MODEL PRICE

COMPAK KHP 15 190 ACS 1 £1,139

COMPAK KHP 35 300 ACS 1 £1,404

Go back to General Contents Go back to AQUATIX Index(Index)

CONDITIONS OF SALE

1. DEFINITIONS

In these Terms and Conditions of Trading: ‘Kaysun UK’ means Kaysun UK,

part of Monodraught Ltd, registered office is at Halifax House, Cressex

Business Park, High Wycombe, Buckinghamshire HP12 3SE, (Company No.

01163485). ‘Buyer’ means the person or firm who acquires the Goods under

the Contract. ‘Conditions’ means these Terms and Conditions of Trading.

‘Contract’ means the contract between Kaysun UK and the Buyer for the

supply of Goods. ‘Goods’ means any Goods sold by Kaysun UK to the Buyer

and unless separately referred to, “Goods” includes any related or connected

services associated with the supply, including any installation, design,

fabrication or construction undertaken by Kaysun UK or its agents. “Order”

means the Buyer’s order for the supply of Goods as set out in the Buyer’s

purchase order form or written acceptance of Kaysun UK’s quotation as the

case may be.

2. CONTRACT

The Buyer’s order constitutes an offer by the Buyer to purchase Goods from

Kaysun UK in accordance with these Conditions. All Orders are accepted by

Kaysun UK subject to the Goods being available. The Order shall only be

deemed to be accepted when Kaysun UK issues a written acknowledgement

of the Order at which point a Contract shall come into existence. These

Conditions apply to the Contract to the exclusion of any other terms and

conditions that the Buyer seeks to impose or incorporate, or which are

implied by trade, custom, practice or course of dealing. Goods shall be

supplied in accordance with Kaysun UK’s acknowledgement of order and

cannot be cancelled, deferred or altered and shall not be subject to reduction

or variation except by mutual agreement confirmed in writing by both

parties and subject to agreement as to related costs.

3. PRICES

All prices quoted by Kaysun UK are valid for a period of six months from the

date of a quotation or from the date of issue of price lists unless otherwise

expressly stated in the quotation or price list. All prices are subject to Valued

Added Tax at the current rate at the time of delivery. All prices quoted are

net trade prices and shall not be subject to retention or net discount, unless

specifically stated in a quotation or acknowledgement of order. Carriage

prices shown in quotations are net prices and are not subject to any discount.

The Buyer will not be entitled to return Goods to Kaysun UK unless Kaysun

UK gives its prior written consent. Kaysun UK’s consent shall always be

subject to (i) the Goods being returned within 90 days of delivery (ii) the

returned Goods being of first class quality and in immediate re-sellable

condition in unbroken packaging, (iii) that the Buyer pays the costs of

returning the Goods to Kaysun UK, and (iv) that the Buyer pays a restocking

charge amounting to 20% of the purchase price for the returned Goods.

Bespoke / Non-Standard Goods subject to a 100% restocking fee. This

provision does not affect the Warranty of Quality at clause 8.

4. DELIVERY

Kaysun UK will use its reasonable endeavours to make deliveries of Goods

on the date/s agreed but time of delivery shall not be of the essence and

Kaysun UK shall not be liable for any delay in delivery for events of Force

Majeure or matters which are the responsibility of the Buyer and shall not

otherwise be liable for delay unless otherwise agreed in writing before

delivery.

5. RISK AND INSURANCE

Risk in the Goods shall pass to the Buyer from the point of delivery to the

Buyer’s address or other agreed place of delivery or on collection by the Buyer

as appropriate, notwithstanding that property in the Goods may be retained

by Kaysun UK in accordance with Clause 7. The Buyer shall be responsible for

effecting its own insurance as appropriate from the date of delivery. Once

the Goods have been delivered or installed the Buyer shall be responsible to

fully protect them and keep them safe.

6. PAYMENT

Payment of any invoice shall become due on the date of Kaysun UK’s

invoice. The final date for payment shall be 30 days after the relevant

invoice becomes due. Amounts unpaid beyond the final date for payment

are payable with interest calculated at the rate of 8% over the base rate of

the Bank of England applicable at the final date for payment until payment

is received in full.

Within 5 days of an invoice becoming due, the Buyer shall notify Kaysun

UK of the sum that the Buyer considers to be due at the payment due date

and the basis on which that sum is calculated (‘payment notice’). Not less

than 7 days before the final date for payment, the Buyer may give notice if

it intends to pay less than the notified sum, specifying the sum considered

to be due and the basis on which that sum is calculated (‘pay less notice’).

Unless the Buyer gives a pay less notice then it shall pay the sum in the

payment notice (or in the absence of a payment notice then the sum in

Kaysun UK’s invoice) on or before the final date for payment of the invoice.

Where part delivery or part service work is carried out, a payment on account

will be payable based on Kaysun UK’s invoice for the relevant amount.

The Buyer shall not be entitled to apply any set off against any sums owing

to Kaysun UK under the Contract any other sums owing to Kaysun UK. If the

Buyer fails to make any payment by the final date for payment then without

prejudice to any other rights Kaysun UK reserves the right to; suspend some

or all obligations under the Contract, or terminate the Contract, or take down

and retrieve any Goods previously installed.

7. RETENTION OF TITLE

Title in the Goods shall remain with Kaysun UK until full payment for the

Goods has been received. Until such time, the Buyer shall keep the Goods

free from any charge, lien or other encumbrance whatsoever and identifiable

as the property of Kaysun UK. Until payment in full for the Goods has been

received, Kaysun UK may at any time require the Goods to be returned to

it and if such requirement is not forthwith complied with, it may retake

possession of the Goods and for such purposes is irrevocably authorised to

enter upon any premises (whether or not occupied by the Buyer) and retrieve

the Goods.

8. WARRANTY OF QUALITY

Kaysun UK warrants that from the date of shipment of the Goods that the

Goods shall, conform with the specification set out in Kaysun UK’s quotation

or acknowledgement of order or if there is no such specification, the Goods

will comply with reasonable standards of quality and will otherwise be

reasonably free from material defects in design, materials and workmanship

when under normal use. This warranty shall apply for 5 years, subject to

maintenance being carried out in accordance with Kaysun UK instructions.

Whilst all product information is given in good faith the use or application

of the Goods is outside the control of Kaysun UK and accordingly Kaysun UK

gives no warranty as to the fitness of the Goods for any particular purpose

and any implied warranty or condition (statutory or otherwise) is excluded

insofar as such exclusion is permitted by law, including in regard to the

suitability of the Goods for the structure where the Goods are to be installed.

It shall be the responsibility of the Buyer to obtain its own professional

guidance on such matters.

The Buyer shall make no claim against Kaysun UK in relation to defects in

the Goods (or shortages in delivery) unless the Buyer has notified Kaysun

UK in writing of the same within 24 hours of delivery. The Buyer must notify

Kaysun UK directly about any such claim (including packaging) relating to

carriage.

In the event of a claim, Kaysun UK must be given a reasonable opportunity

of examining the Goods. If asked to do so the Buyer shall return the Goods to

Kaysun UK at the Buyer’s cost. Kaysun UK at its option, may repair or replace

defective Goods, or refund the price of the relevant Goods.

Kaysun UK shall be under no liability in respect of defects arising from;

the acts or omissions of persons other than Kaysun UK or its authorised

personnel or agents, including but not limited to damage in transit, repairs,

modifications or additions made to the Goods by the end-user or any

other third party; failure to perform appropriate maintenance; continued

use of the Goods after they exhibit signs of any defect or malfunction;

carelessness, mishandling, wear and tear, vandalism or unforeseen events;

use of the Goods contrary to Kaysun UK’s recommendations; any failure or

defect in related products or systems which the Goods have been integrated

with, operate with or are dependent on; defects in materials or workmanship

which are the result of installation by persons other than Kaysun UK.

Kaysun UK shall be under no liability for variations in predicted performance

as compared to performance under actual weather and temperature

levels. Kaysun UK provides calculations and building simulations based on

simulated weather files in accordance with industry standards.

Nothing in these Conditions shall limit or exclude Kaysun UK’s liability for,

death or personal injury caused by its negligence, or the negligence of its

employees, agents or subcontractors; fraud or fraudulent misrepresentation;

or breach of relevant statutory provisions, subject to which Kaysun UK

shall under no circumstances whatever be liable, whether in contract, tort

(including negligence), breach of statutory duty, or otherwise, for any loss

of profit, or any indirect or consequential loss arising under or in connection

with the Contract; and its total liability to the Buyer in respect of all other

losses arising under or in connection with the Contract, whether in contract,

tort (including negligence), breach of statutory duty, or otherwise, shall in no

circumstances exceed the value of the Goods and after taking into account

what is fair and reasonable allowing for the relative contributions to any loss

suffered by the Buyer of Kaysun UK and other parties who have entered into

any arrangements (contractual or otherwise) with the Buyer in connection

with the Goods or related project or works.

Except as set out in these Conditions, all warranties, conditions and other

terms implied by statute or common law are, to the fullest extent permitted

by law, excluded from the Contract.

Kaysun UK will at its sole discretion undertake for the Buyer or any end user

of the Goods, the repair or replacement of the relevant Goods at its own

cost and so that the Goods conform to the Contract. If however in Kaysun

UK’s reasonable opinion, the end-user is unable to establish a failure on

Kaysun UK to comply with the Contract then the Buyer shall be responsible

for all costs and expenses incurred by Kaysun UK in investigating any alleged

breach.

9. FORCE MAJEURE

Notwithstanding any agreement to the contrary, any delivery may be totally

or partially suspended by Kaysun UK as a result in delay in manufacture,

supply or delivery arising from acts of God, unforeseeable circumstances,

acts of Government or local authority, war, revolution, fires, ice, strikes,

industrial disputes, inability to obtain necessary and proper materials,

facilities, transportation or labour or any other cause beyond Kaysun UK’s

control. Any Goods, the delivery of which has not been totally or partially

suspended shall be accepted by the Buyer as soon as it is reasonably

practicable after the reason for delay has abated.

10. TERMINATION

Either party may terminate the Contract with immediate effect by giving

written notice to the other party if; the other party commits a material breach

of its obligations under the Contract and fails to remedy that breach within

14 days after receipt of the written notice; or the other party suspends, or

threatens to suspend, payment of its debts or is unable to pay its debts as

they fall due or admits inability to pay its debts or; a petition is filed, a notice

is given, a resolution is passed, or an order is made, for or in connection with

the winding up or bankruptcy of the other party; an application is made to

court, or an order is made, for the appointment of an administrator; or a

receiver is appointed over the assets of the other party; or any event occurs,

or proceeding is taken, with respect to the other party that has an effect

equivalent or similar to any of the aforementioned events.

In the event of any termination of a Contract by the Buyer prior to any

goods or services being provided, the buyer shall pay a cancellation charge

amounting to 15% of the purchase price of the Contract.

On termination of the Contract for any reason; the Buyer shall immediately

pay all of Kaysun UK’s outstanding unpaid invoices and interest and shall

return all of the Goods which have not been fully paid for. If the Customer

fails to do so, then the Supplier may enter the Customer’s premises and

take possession of them. Until they have been returned, the Customer shall

be solely responsible for their safe keeping and will not use them for any

purpose not connected with the Contract.

The accrued rights and remedies of the parties as at termination shall not

be affected, including the right to claim damages in respect of any breach

of the Contract, which existed at or before the date of termination or expiry;

and clauses which expressly or by implication have effect after termination

shall continue in full force and effect.

11. LAW

The Contract shall be subject to English law and the English Courts. A

person who is not a party to the Contract shall not have any rights under

or in connection with it. Either party may refer a dispute arising under

the Contract to adjudication at any time under Part I of the Scheme for

Construction Contracts (England and Wales) Regulations, which Part shall

take effect as if it was incorporated into this clause.

12. SPECIFICATIONS AND IMAGES

Kaysun UK reserves the right to change the specifications and images of the

Goods without prior notice.

Kaysun UK

1st August 2017

These Terms and Conditions supersede

all previous Terms and Conditions.

Main Office

Halifax HouseHigh WycombeBuckinghamshireHP12 3SETel. (+44) 01494 897700

Kaysun participates in the EUROVENT certification program. The products correspond to those listed into the EUROVENT certified products directory.

*KAYSUN UK - A Monodraught Company


Recommended