Chris Clegg

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 2 of 40 Issue 1

CONTENTS

1 Introduction ..................................................................................................................... 3

2 Test Specification ............................................................................................................ 5 2.1 Environment.............................................................................................................. 5 2.2 Relevant standards .................................................................................................... 5

2.2.1 Emissions .......................................................................................................... 5 2.2.2 Immunity........................................................................................................... 5

3 Test Results ...................................................................................................................... 6 3.1 Conducted emissions (9kHz to 30MHz)................................................................... 6 3.2 Radiated emissions (30MHz to 1000MHz) ............................................................ 16 3.3 Magnetic emissions (9kHz to 30MHz) (Not UKAS accredited) ............................ 17 3.4 Harmonic emissions................................................................................................ 19

4 Summary ........................................................................................................................ 20 4.1 Emissions ................................................................................................................ 20 4.2 Immunity................................................................................................................. 21 4.3 Compliance statement ............................................................................................. 21

5 Appendices ..................................................................................................................... 22 5.1 Appendix 1 Conducted emission test method (9kHz to 150kHz).......................... 22

5.1.1 Test information.............................................................................................. 22 5.2 Appendix 2 Conducted emission test method (150kHz to 30MHz) ...................... 23

5.2.1 Test information.............................................................................................. 23 5.3 Appendix 3 Harmonic emissions test method (50 to 2000Hz) .............................. 24

5.3.1 Test information.............................................................................................. 24 5.4 Appendix 4 Radiated emission test method (30MHz to 1000MHz)...................... 25

5.4.1 Test information.............................................................................................. 25 5.5 Appendix 5 Conducted emission test results ......................................................... 26 5.6 Appendix 6 Radiated emission test results ............................................................ 30 5.7 Appendix 7 Magnetic emission test results (Loop Antenna).................................. 31 5.8 Appendix 8 Harmonic emissions test results .......................................................... 33 5.9 Appendix 9 EUT test configurations ..................................................................... 34 5.10 Appendix 10 Reporting the results......................................................................... 37 5.11 Appendix 11 Equipment used................................................................................ 38 5.12 Appendix 12 Exercising equipment used ............................................................... 39 5.13 Appendix 13 Modification States ........................................................................... 40

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 3 of 40 Issue 1

1 Introduction Name and address of laboratory: York EMC Services Ltd Three Lane Ends Business Centre Methley Road Castleford West Yorkshire WF10 1PN UKAS testing laboratory N° 1574

Name and address of client: Radiocommunications Agency Wyndham 180 Marsh Wall London E14 9SX The test results contained in this test report relate only to the unit(s) tested.

EUT 6 – Plug in switched mode power supply

Equipment under test

Manufacturer Egston Product name EUT 6 – Plug in switched mode power supply Model number N2GFSW Serial number N/A No. tested of each item One Customer supplied test plan ref. York EMC Services Ltd Document 8214CR2

Date of receipt of EUT 20th May 2003 Method of receipt Posted by Customer Date(s) of test(s) 20th, 21st, 22nd, 23rd, 27th, 28th, 29th and 30th May

2003 Date(s) when EUT was out of laboratory’s control

None

Method of disposal Awaiting dispatch All tests witnessed by Mr Mahesh Dudhia of the Radiocommunications Agency.

Personnel witnessing tests

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 4 of 40 Issue 1

Any other relevant information: EUT 6 denotes that the printer switched mode power supply was equipment under test number 6 out of a total of 10. During the tests the power supply was subjected to a number of load conditions (25, 50 and 100%), which were set using an external load box consisting of capacitor and resistors. This was built by York EMC Services Ltd as part of an overall project to study the EMC emissions from switched mode power supplies and similar switched electronic load controllers under different load conditions.

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 5 of 40 Issue 1

2 Test Specification

2.1 Environment

The equipment under test is a 12V DC output switched mode power supply manufactured by Egston.

2.2 Relevant standards 2.2.1 Emissions

Product Specific Standard

Basic Standard Class/limit Test

Radiated emissions EN55022:1998

B 3 EN55022:1998

Conducted emissions ac power port EN55022:1998 (See Note 4)

B 1

Conducted emissions ac power port EN55015:2000+A1:2001 (See Note 3)

Limits as per table 2a 1

Magnetic emissions EN55011:1998 (Pre-compliance)

As defined in table 3b 4

Harmonic emissions EN61000-3-2:2000

D 2

Note 1: The EUT is to be tested in three modes of operation unless specifically stated otherwise.

Note 2: The individual tests were specifically requested by the customer, in order that direct

comparisons could be made with a number of similar EUTs.

Note 3: Conducted emission measurements made in the frequency range 9kHz to 150kHz were

compared against limit line in EN55015:2000+A1:2001.

Note 4: The customer requested a class D limit for harmonic emissions for in order direct

comparisons can be made between items for the purposes of the investigation, a common limit was

used to test all items.

2.2.2 Immunity

No immunity testing was requested.

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 6 of 40 Issue 1

3 Test Results

3.1 Conducted emissions (9kHz to 30MHz)

Mode of operation Description Mode No.

230V AC, 100% load 1

230V AC, 50% load 2

230V AC, 25% load 3

Test standard Test description Class/limit

EN55022:1998 Conducted emissions ac power (150kHz-30MHz) B

EN55015:2000+A1:2001 Conducted emissions ac power (9kHz-150kHz) Limit as per table 2a

Results Mode Figure Result Comments

1 C01 LU Live

C02 Pass Neutral

2 C03 Pass Live

C04 Pass Neutral

3 C05 Pass Live

C06 Pass Neutral

1 C07 Pass Live (1m extended cable attached)

C08 Pass Neutral (1m extended cable attached)

2 C09 Pass Live (1m extended cable attached)

C10 Pass Neutral (1m extended cable attached)

3 C11 Pass Live (1m extended cable attached)

C12 Pass Neutral (1m extended cable attached)

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 7 of 40 Issue 1

QP Results

Mode Freq (MHz)

QP level (dBuV)

Comments

0.190 56.00 Live 1

0.195 60.50 Live

0.290 48.80 Live

0.380 36.40 Live

0.385 43.40 Live

0.390 51.60 Live

Average Results

Mode Freq (MHz)

Av level (dBuV)

Comments

0.190 42.10 Live

0.195 51.50 Live

0.285 25.10 Live

0.290 43.60 Live

0.385 30.40 Live

1

0.675 14.60 Live

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 8 of 40 Issue 1

QP Results

Mode Freq (MHz)

QP level (dBuV)

Comments

0.190 52.20 Neutral

0.195 60.10 Neutral

0.200 59.90 Neutral

1

0.295 50.70 Neutral

0.390 49.90 Neutral

0.395 50.90 Neutral

Average Results

Mode Freq (MHz)

Av level (dBuV)

Comments

0.195 50.90 Neutral

0.200 49.30 Neutral

0.290 40.60 Neutral

0.295 46.20 Neutral

0.300 39.80 Neutral

1

0.395 38.10 Neutral

QP Results

Mode Freq (MHz)

QP level (dBuV)

Comments

0.235 52.40 Live

0.240 54.00 Live

2

0.245 49.70 Live

0.360 48.80 Live

0.475 43.80 Live

0.480 43.40 Live

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 9 of 40 Issue 1

Average Results

Mode Freq (MHz)

Av level (dBuV)

Comments

0.235 41.40 Live

0.240 43.50 Live

0.245 38.00 Live

0.355 35.40 Live

0.360 35.60 Live

2

0.475 31.40 Live

QP Results

Mode Freq (MHz)

QP level (dBuV)

Comments

0.235 52.90 Neutral

0.240 53.80 Neutral

0.245 49.70 Neutral

0.250 47.50 Neutral

0.355 48.60 Neutral

2

0.360 48.50 Neutral

Average Results

Mode Freq (MHz)

Av level (dBuV)

Comments

0.235 41.50 Neutral

0.240 43.30 Neutral

0.245 37.60 Neutral

0.355 35.40 Neutral

0.360 35.30 Neutral

2

0.475 31.30 Neutral

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 10 of 40 Issue 1

QP Results

Mode Freq (MHz)

QP level (dBuV)

Comments

0.155 54.00 Live

0.160 54.10 Live

0.165 54.60 Live

3

0.170 52.30 Live

0.310 43.70 Live

0.315 43.70 Live

Average Results

Mode Freq (MHz)

Av level (dBuV)

Comments

0.155 39.20 Live

0.160 39.20 Live

0.165 39.00 Live

3

0.300 32.90 Live

0.305 33.90 Live

0.315 33.10 Live

QP Results

Mode Freq (MHz)

QP level (dBuV)

Comments

0.160 54.50 Neutral

0.165 55.40 Neutral

0.170 54.60 Neutral

0.315 43.70 Neutral

0.335 43.60 Neutral

3

0.340 43.20 Neutral

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 11 of 40 Issue 1

Average Results

Mode Freq (MHz)

Av level (dBuV)

Comments

0.160 39.70 Neutral

0.165 39.40 Neutral

0.170 37.90 Neutral

0.315 32.80 Neutral

0.320 32.50 Neutral

3

0.325 31.80 Neutral

QP Results

Mode Freq (MHz)

QP level (dBuV)

Comments

0.190 50.70 Live (1m extended cable attached) 1

0.195 57.80 Live (1m extended cable attached)

0.200 57.30 Live (1m extended cable attached)

0.290 45.10 Live (1m extended cable attached)

0.295 48.60 Live (1m extended cable attached)

0.395 49.80 Live (1m extended cable attached)

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 12 of 40 Issue 1

Average Results

Mode Freq (MHz)

Av level (dBuV)

Comments

0.190 35.70 Live (1m extended cable attached)

0.195 48.10 Live (1m extended cable attached)

0.290 38.90 Live (1m extended cable attached)

0.295 44.10 Live (1m extended cable attached)

0.385 22.60 Live (1m extended cable attached)

1

0.390 35.10 Live (1m extended cable attached)

QP Results

Mode Freq (MHz)

QP level (dBuV)

Comments

0.195 57.20 Neutral (1m extended cable attached)

0.200 57.90 Neutral (1m extended cable attached)

0.295 48.00 Neutral (1m extended cable attached)

1

0.300 48.10 Neutral (1m extended cable attached)

0.395 49.60 Neutral (1m extended cable attached)

0.400 48.80 Neutral (1m extended cable attached)

Average Results

Mode Freq (MHz)

Av level (dBuV)

Comments

0.195 46.90 Neutral (1m extended cable attached)

0.200 47.70 Neutral (1m extended cable attached)

0.295 43.60 Neutral (1m extended cable attached)

0.300 41.60 Neutral (1m extended cable attached)

0.395 36.60 Neutral (1m extended cable attached)

1

0.790 32.80 Neutral (1m extended cable attached)

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 13 of 40 Issue 1

QP Results

Mode Freq (MHz)

QP level (dBuV)

Comments

0.235 50.40 Live (1m extended cable attached)

0.240 53.30 Live (1m extended cable attached)

2

0.245 49.30 Live (1m extended cable attached)

0.355 47.30 Live (1m extended cable attached)

0.360 49.60 Live (1m extended cable attached)

0.480 46.30 Live (1m extended cable attached)

Average Results

Mode Freq (MHz)

Av level (dBuV)

Comments

0.235 37.70 Live (1m extended cable attached)

0.240 41.10 Live (1m extended cable attached)

0.245 36.70 Live (1m extended cable attached)

0.355 32.60 Live (1m extended cable attached)

0.360 34.20 Live (1m extended cable attached)

2

0.475 29.10 Live (1m extended cable attached)

QP Results

Mode Freq (MHz)

QP level (dBuV)

Comments

0.235 50.60 Neutral (1m extended cable attached)

0.240 53.20 Neutral (1m extended cable attached)

0.245 49.00 Neutral (1m extended cable attached)

0.355 45.80 Neutral (1m extended cable attached)

0.475 43.60 Neutral (1m extended cable attached)

2

0.480 44.10 Neutral (1m extended cable attached)

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 14 of 40 Issue 1

Average Results

Mode Freq (MHz)

Av level (dBuV)

Comments

0.235 38.00 Neutral (1m extended cable attached)

0.240 41.00 Neutral (1m extended cable attached)

0.245 36.30 Neutral (1m extended cable attached)

0.355 32.60 Neutral (1m extended cable attached)

0.360 33.90 Neutral (1m extended cable attached)

2

0.475 29.10 Neutral (1m extended cable attached)

QP Results

Mode Freq (MHz)

QP level (dBuV)

Comments

0.160 50.00 Live (1m extended cable attached)

0.165 50.90 Live (1m extended cable attached)

0.170 50.20 Live (1m extended cable attached)

3

0.325 40.80 Live (1m extended cable attached)

0.335 40.80 Live (1m extended cable attached)

0.340 40.40 Live (1m extended cable attached)

Average Results

Mode Freq (MHz)

Av level (dBuV)

Comments

0.160 35.10 Live (1m extended cable attached)

0.165 34.80 Live (1m extended cable attached)

0.315 30.90 Live (1m extended cable attached)

3

0.320 30.70 Live (1m extended cable attached)

0.325 29.90 Live (1m extended cable attached)

0.335 29.60 Live (1m extended cable attached)

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 15 of 40 Issue 1

QP Results

Mode Freq (MHz)

QP level (dBuV)

Comments

0.155 49.50 Neutral (1m extended cable attached)

0.160 49.70 Neutral (1m extended cable attached)

0.165 50.50 Neutral (1m extended cable attached)

0.170 48.30 Neutral (1m extended cable attached)

0.305 41.90 Neutral (1m extended cable attached)

3

0.315 41.20 Neutral (1m extended cable attached)

Average Results

Mode Freq (MHz)

Av level (dBuV)

Comments

0.305 31.70 Neutral (1m extended cable attached)

0.310 31.00 Neutral (1m extended cable attached)

0.315 30.90 Neutral (1m extended cable attached)

0.320 30.40 Neutral (1m extended cable attached)

0.325 29.70 Neutral (1m extended cable attached)

3

0.330 30.10 Neutral (1m extended cable attached)

Note 1: EUT 6 was tested was tested in two states in order to cover any confusion in the standard regarding how to test the EUT, either by plugging the EUT directly into the LISN or with a 1m cable attached. (See Appendix 7):

(State 1: Plugged directly into LISN)

(State 2: 1m extended cable attached to EUT before plugged into LISN)

Modifications Required for this test Modification state

None 0

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 16 of 40 Issue 1

3.2 Radiated emissions (30MHz to 1000MHz)

Mode of operation Description Mode No.

230V AC, 100% load 1

230V AC, 50% load 2

230V AC, 25% load 3

Test standard Test description Class/limit

EN55022:1998 Radiated emissions B

Results Mode Figure Result Comments

1 R01 Pass Both polarisations, all 4 sides of EUT.

(Chamber measurement)

2 R02 Pass Both polarisations, all 4 sides of EUT.

(Chamber measurement)

3 R03 Pass Both polarisations, all 4 sides of EUT.

(Chamber measurement)

Note 1: Due to the low level of emissions measured from the EUT, no OATS measurements were made at the request of the customer.

Modifications Required for this test Modification state

None 0

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 17 of 40 Issue 1

3.3 Magnetic emissions (9kHz to 30MHz) (Not UKAS accredited)

Mode of operation Description Mode No.

230V AC, 100% load 1

230V AC, 50% load 2

230V AC, 25% load 3

Test standard Test description Class/limit

EN55011:1998 Radiated emissions Limit as defined in table 3b

Results Mode Figure Result Comments

1 R01 Pass One face of EUT, antenna parallel to EUT.

R02 Pass One face of EUT, antenna perpendicular to EUT.

2 R03 Pass One face of EUT, antenna parallel to EUT.

R04 Pass One face of EUT, antenna perpendicular to EUT.

3 R05 Pass One face of EUT, antenna parallel to EUT.

R06 Pass One face of EUT, antenna perpendicular to EUT.

1 R07 Pass One face of EUT, antenna parallel to EUT.

1m distance

R08 Pass One face of EUT, antenna perpendicular to EUT.

1m distance

2

R09 Pass One face of EUT, antenna parallel to EUT.

1m distance

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 18 of 40 Issue 1

Results Mode Figure Result Comments

3

R10 Pass One face of EUT, antenna perpendicular to EUT.

1m distance

R11 Pass One face of EUT, antenna parallel to EUT.

1m distance

R12 Pass One face of EUT, antenna perpendicular to EUT.

1m distance

Note 1: The magnetic emissions tests were carried as pre-compliance tests at a distance of 3m and 1m, with a fixed antenna height in an anechoic chamber. During the tests the front face of the EUT was facing the antenna. Only one face was tested, (See Appendix 7, magnetic emissions 5.7.4).

Modifications Required for this test Modification state

None 0

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 19 of 40 Issue 1

3.4 Harmonic emissions

Mode of operation Description Mode No.

230V AC, 100% load 1

230V AC, 50% load 2

230V AC, 25% load 3

Test standard Test description Class/limit

EN61000-3-2:2000 Harmonic emissions D

Results Mode Figure Result Comments

1 H01 Fail None

2 H02 Fail None

3 H03 Fail None

Note 1: The customer requested class D limit for harmonic emissions for in order direct comparisons

can be made between items for the purposes of the investigation, a common limit was used to test all

items.

Modifications Required for this test Modification state

None 0

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 20 of 40 Issue 1

4 Summary

4.1 Emissions

Product Specific Standards EN55022:1998 and EN55015:2000+A1:2001

Basic Standard Class/limit Result Radiated emissions EN55022:1998

B Pass (Case A)

Conducted emissions ac power port EN55022:1998 (See Note 4)

B Lower uncertainty (Case B)

Conducted emissions ac power port EN55015:2000+A1:2001 (See Note 3)

Limits as per table 2a Pass (Case A)

Magnetic emissions EN55011:1998 (Pre-compliance)

As defined in table 3b Pass (Case A)

Harmonic emissions EN61000-3-2:2000

D Fail (Case D)

Note 1: The EUT is to be tested in three modes of operation unless specifically stated otherwise.

Note 2: The individual tests were specifically requested by the customer, in order that direct

comparisons could be made with a number of similar EUTs.

Note 3: Conducted emission measurements made in the frequency range 9kHz to 150kHz were

compared against limit line in EN55015:2000+A1:2001.

Note 4: The customer requested class D limit for harmonic emissions for in order direct comparisons

can be made between items for the purposes of the investigation, a common limit was used to test all

items.

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 21 of 40 Issue 1

4.2 Immunity

No immunity testing was requested.

4.3 Compliance statement

The EUT 6 – Plug in switched mode power supply, as tested, was shown to meet the requirements of the standards listed in 4.1 of this report, with the exception of harmonic emissions and conducted emissions.

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 22 of 40 Issue 1

5 Appendices

5.1 Appendix 1 Conducted emission test method (9kHz to 150kHz) 5.1.1 Test information

Standard EN55015:2000+A1:2001

YES Test Method CEP19

Measurement uncertainty

+/- 1.76dB

Equipment Used Rohde & Schwarz ESHS10 receiver Rohde & Schwarz ESH3-Z5 LISN Chase 9206 transient limiter

Note: Specific set-ups for the EUT are shown in EUT test configurations section of this report (where applicable).

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 23 of 40 Issue 1

5.2 Appendix 2 Conducted emission test method (150kHz to 30MHz) 5.2.1 Test information

Standard EN55022:1998

YES Test Method CEP19

Measurement uncertainty

+/- 2.38dB

Equipment Used Rohde & Schwarz ESHS10 receiver Rohde & Schwarz ESH3-Z5 LISN Chase 9206 transient limiter

Note: Specific set-ups for the EUT are shown in EUT test configurations section of this report (where applicable).

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 24 of 40 Issue 1

5.3 Appendix 3 Harmonic emissions test method (50 to 2000Hz) 5.3.1 Test information

Standard EN61000-3-2:2000

YES Test Method CEP17

Measurement uncertainty

Greater of 5% of limit or 0.2% of rated current

Equipment Used Schaffner Profline Test System Serial No. 5377 Consisting of: Voltech PM3000A Analyser Serial No. 9159 CCN2000 Interface Serial No. IN0496-005 UPC-32 Controller Serial No. 0289 0345 AMXT Magnetics module Serial No. 0271

Note: Specific set-ups for the EUT are shown in EUT test configurations section of this report (where applicable).

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 25 of 40 Issue 1

5.4 Appendix 4 Radiated emission test method (30MHz to 1000MHz) 5.4.1 Test information

Standards EN55022:1998

YES Test Method CEP23

Measurement uncertainty

N/A

Equipment Used Rohde & Schwarz receiver Bilog antenna Rohde & Schwarz positioning mast and controller EMCO 2m diameter turntable and controller

Note: Specific set-ups for the EUT are shown in EUT test configurations section of this report (where applicable).

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 26 of 40 Issue 1

5.5 Appendix 5 Conducted emission test results

Figure 5.5.1 Conducted emissions results, (Live quasi peak measurement).

Figure 5.5.2 Conducted emissions results, (Live average measurement).

Conducted Emission (Live) Peak Measurement

0

20

40

60

80

100

120

0.001 0.01 0.1 1 10 100

frequency (MHz)

Con

duct

ed E

mis

sion

(dB

uV)

100% Load 50% Load 25% Load Noise FloorQuasi-Peak - 100% Load Quasi-Peak - 50% Load Quasi-Peak - 25% Load Limit EN55015 and EN55022 - QP

Conducted Emission (Live) Average Measurement

0

10

20

30

40

50

60

0.001 0.01 0.1 1 10 100

frequency (MHz)

Con

duct

ed E

mis

sion

(dB

uV)

100% Load 50% Load 25% Load Noise Floor AV - 100% Load" AV - 50% Load" AV - 25% Load" Limit EN55022 - AV

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 27 of 40 Issue 1

Figure 5.5.3 Conducted emissions results, (Neutral quasi peak measurement).

Figure 5.5.4 Conducted emissions results, (Neutral average measurement).

Conducted Emission (Neutral) Peak Measurement

0

20

40

60

80

100

120

0.001 0.01 0.1 1 10 100

frequency (MHz)

Con

duct

ed E

mis

sion

(dB

uV)

100% Load 50% Load 25% Load Noise FloorQuasi-Peak - 100% Load Quasi-Peak - 50% Load Quasi-Peak - 25% Load Limit EN55015 and EN55022 - QP

Conducted Emission (Neutral) Average Measurement

0

10

20

30

40

50

60

0.001 0.01 0.1 1 10 100

frequency (MHz)

Con

duct

ed E

mis

sion

(dB

uV)

100% Load 50% Load 25% Load Noise Floor AV - 100% Load" AV - 50% Load" AV - 25% Load" Limit EN55022 - AV

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 28 of 40 Issue 1

Figure 5.5.5 Conducted emissions results, 1m extended cable (Live quasi peak measurement).

Figure 5.5.6 Conducted emissions results, 1m extended cable (Live average measurement).

Conducted Emission (Live) Peak Measurement, with 1m extended cable

0

20

40

60

80

100

120

0.001 0.01 0.1 1 10 100

frequency (MHz)

Con

duct

ed E

mis

sion

(dB

uV)

100% Load 50% Load 25% Load Noise FloorQuasi-Peak - 100% Load Quasi-Peak - 50% Load Quasi-Peak - 25% Load Limit EN55015 and EN55022 - QP

Conducted Emission (Live) Average Measurement, with 1m extended cable

0

10

20

30

40

50

60

0.001 0.01 0.1 1 10 100

frequency (MHz)

Con

duct

ed E

mis

sion

(dB

uV)

100% Load 50% Load 25% Load Noise Floor AV - 100% Load" AV - 50% Load" AV - 25% Load" Limit EN55022 - AV

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 29 of 40 Issue 1

Figure 5.5.7 Conducted emissions results, 1m extended cable (Neutral quasi peak measurement).

Figure 5.5.8 Conducted emissions results, 1m extended cable (Neutral average measurement).

Conducted Emission (Neutral) Peak Measurement, with 1m extended cable

0

20

40

60

80

100

120

0.001 0.01 0.1 1 10 100

frequency (MHz)

Con

duct

ed E

mis

sion

(dB

uV)

100% Load 50% Load 25% Load Noise FloorQuasi-Peak - 100% Load Quasi-Peak - 50% Load Quasi-Peak - 25% Load Limit EN55015 and EN55022 - QP

Conducted Emission (Neutral) Average Measurement, with 1m extended cable

0

10

20

30

40

50

60

0.001 0.01 0.1 1 10 100

frequency (MHz)

Con

duct

ed E

mis

sion

(dB

uV)

100% Load 50% Load 25% Load Noise Floor AV - 100% Load" AV - 50% Load" AV - 25% Load" Limit EN55022 - AV

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 30 of 40 Issue 1

5.6 Appendix 6 Radiated emission test results

Figure 5.6.1 Radiated emissions results (Chamber).

Note 1: The frequencies at approximately 40MHz, 90MHz –100MHz, and 188.76MHz were ambient signals.

Combined Horizontal & Vertical Polarisations Peak Measurement

0

5

10

15

20

25

30

35

40

45

50

10 100 1000

Frequency (MHz)

Rad

iate

d Em

issi

ons

(dB

uV/m

)

Noise Floor 100% 50% Load 25% Load Limit EN55022 Class B

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 31 of 40 Issue 1

5.7 Appendix 7 Magnetic emission test results (Loop Antenna)

Figure 5.7.1 Magnetic emissions results, parallel, distance 3m (Chamber).

Figure 5.7.2 Magnetic emissions results, perpendicular, distance 3m (Chamber).

Parallel Loop Peak Measurement - 3metres

-80

-60

-40

-20

0

20

40

60

80

0.001 0.01 0.1 1 10 100

Frequency (MHz)

Mag

netic

Fie

ld (d

BuA

/m)

Noise Floor 25% Load 50% Load 100% Load Limit EN55011 - QP

Perpendicular Loop Peak measurement - 3metres

-80

-60

-40

-20

0

20

40

60

80

0.001 0.01 0.1 1 10 100

Frequency (MHz)

Mag

netic

Fie

ld (d

BuA

/m)

Noise Floor 25% Load 50% Load 100% Load Limit EN55011 - QP

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 32 of 40 Issue 1

Figure 5.7.3 Magnetic emissions results, parallel, distance 1m (Chamber).

Figure 5.7.4 Magnetic emissions results, perpendicular, distance 1m (Chamber).

Parallel Loop Peak Measurement - 1metre

-80

-60

-40

-20

0

20

40

60

80

0.001 0.01 0.1 1 10 100

Frequency (MHz)

Mag

netic

Fie

ld (d

BuA

/m) a

t 1m

dis

tanc

e

Noise Floor 25% Load 50% Load 100% Load Limit EN55011 (3m)

Perpendicular Loop peak measurement - 1metre

-80

-60

-40

-20

0

20

40

60

80

0.001 0.01 0.1 1 10 100

Frequency (MHz)

Mag

netic

Fie

ld (d

BuA

/m) a

t 1m

dis

tanc

e

Noise Floor 25% Load 50% Load 100% Load Limit EN55011 (3m)

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 33 of 40 Issue 1

5.8 Appendix 8 Harmonic emissions test results

Figure 5.8.1 Harmonic emissions results.

EUT 5

0

5

10

15

20

25

30

35

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

Harmonics

mA

100% limitMode 1 100%Mode 2 50%Mode 3 25%

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 34 of 40 Issue 1

5.9 Appendix 9 EUT test configurations

Photograph 5.9.1 Conducted emissions testing

Photograph 5.9.2 Conducted emissions testing, 1m extended cable

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 35 of 40 Issue 1

Photograph 5.9.3 Conducted emissions testing, 1m extended cable

Photograph 5.9.4 Radiated emissions testing

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 36 of 40 Issue 1

Photograph 5.9.5 Magnetic emissions testing (Loop antenna)

Photograph 5.9.6 Harmonic emissions testing

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 37 of 40 Issue 1

5.10 Appendix 10 Reporting the results

Case A The equipment complies with the stated specification of the measured points, due allowance having been made for the uncertainty of the measurements. It may be deemed as a pass. Case B The measured result is below the specification limit by a margin less than the measurement uncertainty; it is therefore not possible to state compliance based on the stated level of confidence. However the result indicates that compliance is more probable than non-compliance with the specification limit. It is a likely pass but within the measurement uncertainty. Case C The measured result is above the specification limit by a margin less than the measurement uncertainty; it is therefore not possible to state compliance based on the stated level of confidence. However the result indicates that non-compliance is more probable than compliance with the specification limit. It is a likely fail but within the measurement uncertainty. Case D The equipment does not comply with the stated specification of the measured points, due allowance having been made for the uncertainty of the measurements. It may be deemed as a fail.

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 38 of 40 Issue 1

5.11 Appendix 11 Equipment used Equipment No. Cal Type Used Equipment No. Cal Type Used

AR FM2000 Field Probe Set 78108 R&S SMY02 Signal Generator 78653 UKAS AR FM2000 Field Probe Set 78211 UKAS Rolfe Heine 200A 3 Phase LISN 78206 UKAS AR50W1000 50W Amplifier 78313 NCS Rolfe Heine 32A 3 Phase LISN 78205 UKAS Blackstar Function Generator 78200 In-house Schaffner NSG1025 EFT/B Generator 78136 UKAS

Chase Van Veen Loop 78217 In-house Schaffner NSG2025 EFT/B Generator 78006 UKAS Chase CBL 6111A Bilog Antenna 78167 UKAS Schaffner NSG2050 + PNW2055 78178 UKAS Chase CBL 6112B Bilog Antenna 78708 UKAS Schaffner EM clamp 79045 NCS Chase CBL 6140 X-Wing Antenna 78310 In-house ! Chase CFL 9206 Transient Limiter 78101 In-house Schaffner NSG435 ESD Simulator 78008 UKAS Chase CFL 9206 Transient Limiter 78087 In-house !

Chase HLA6120 Loop Antenna 78128 NPL ! Schaffner NSG650 + CDN113 78478 UKAS Chase MDS21 Absorbing Clamp 78195 UKAS Schaffner NSG2050 + PNW2056 78458 UKAS

EMCO 3115 Double Ridged Horn 78347 Manufac Schaffner Profline 78374 UKAS ! Fischer FCC-801-M1-16 CDN 78240 UKAS Schaffner voltage probe CVP2200 78596 UKAS Fischer FCC-801-M2-25 CDN 78241 UKAS Schaffner current probe SMZ11 78569 UKAS Fischer FCC-801-M2-16 CDN 78400 UKAS Schaffner T200 ISN 78591 UKAS Fischer FCC-801-M3-16 CDN 78044 UKAS Schaffner T400 ISN 78570 UKAS Fischer FCC-801-M3-25 CDN 78242 UKAS Schaffner Chase CBL6111C 78707 UKAS Fischer FCC-801-M4-25 CDN 78045 UKAS Schaffner Chase CBL6112B 78708 Manufac

Fischer EM clamp 78130 NCS Schaffner INA 175 surge CDN 78461 In-house Fischer FCC-801-T2 78372 UKAS Schaffner INA 172 surge CDN 78462 In-house

Fluke 45 Digital Mutimeter 78655 UKAS Solar 9108-IN Current Probe 78545 UKAS Fluke 85 Digital Mutimeter 78375 UKAS Voltech PM3000A Harmonic Analyser 78342 UKAS !

Gould 475 Digital Oscilloscope 78057 UKAS Fischer FCC-801-M3-25 CDN 79002 UKAS HP Infinium oscilloscope 78654 UKAS Fischer FCC-801 M1-16 CDN 79001 UKAS

HP programmable power supply 78657 UKAS EM Test UCS 500 79059 UKAS Instek GFG-8020H 78673 In-house Fischer FCC-801-M1-16 CDN

ISO-TECH ICA32N current transducer 78677 NCS Fisher FCC-801-M3-25 CDN 79002 UKAS ISO-TECH 9053 LCR meter 78487 NCS Keytek AC line qualifier 78350 UKAS

Keytek EMC Pro 78348 UKAS Spitzenberger & Spies power source 78131 NCS Keytek MZ-15/EC ESD Simulator 78133 UKAS 6dB attenuator 79073 In-house

LEM HEME LH2015 true RMS meter 78483 NCS 6dB attenuator 79074 In-house Marconi 2390 78349 UKAS Magnetic immunity loop (single) 78475 In-house

R&S ESH3-Z5 LISN 78037 UKAS Magnetic immunity loop (multi) 78722 In-house R&S ESH3-Z5 LISN 78119 UKAS ! Wandel & Golterman EFA-2 78551 Manufac

R&S ESHS 10 Receiver 78035 UKAS ! Schaffner EFT/B clamp 78690 In-house R&S ESHS10 Receiver 78106 UKAS ! 78192 N/A R&S ESVS 30 Receiver 78108 UKAS ! R&S ESVS10 Receiver 78036 UKAS

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 39 of 40 Issue 1

5.12 Appendix 12 Exercising equipment used Equipment Serial number Cal status

Load box 7 N/A None

Radiocommunications Agency EMC testing of EUT 6 – Plug in Power Supply 5534/TR/1

York EMC Services Page 40 of 40 Issue 1

5.13 Appendix 13 Modification States

Modification state Modification

0 As supplied by the customer.


Recommended