8/13/2019 18 Introduction to Genex Assistance
1/50
Huawei TECHNOLOGIES Co., Ltd.Huawei Confidential 1
BYMOD TY GI
INTRODUCTION
TO
GENEX SSIST NCE
8/13/2019 18 Introduction to Genex Assistance
2/50
Huawei TECHNOLOGIES Co., Ltd.Huawei Confidential2
The GENEX Assistant is excellent software tool for
Post-Processing 2G & 3G Drive Test Data.
With the GENEX Assistant, you can:
Have a panorama view of network performance
Locate network troubles
Improve network quality
Verify network planning and optimization
8/13/2019 18 Introduction to Genex Assistance
3/50
Huawei TECHNOLOGIES Co., Ltd.Huawei Confidential3
Functions of the Genex Assistant
Analyzing the test data in WCDMA GSM dual mode
The Assistant analyzes the test data in the WCDMA and GSM networks
The Assistant also has the independent display systems for separately
displaying the engineering parameters and real-time data
Test data playback
The Assistant supports
Manual or automatic play of the test dataDisplay of measurement parameters for trouble spots in detailNetwork problems locating in a quick manner
8/13/2019 18 Introduction to Genex Assistance
4/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
4
FOR POST PROCESSING OF LOGFILE IN
GENEX ASSISTANCE WE NEED TO
OPEN A NEW PROJECT
ANALYSIS OF LOGFILE
8/13/2019 18 Introduction to Genex Assistance
5/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
5
NEW PROJECT
STEP-1 PROJECT NAME ( TEST 01 )
STEP-2 PROJECT PATH ( LOCATION TO SAVE THE PROJECT )
STEP-3 MAP PATH ( Insert the Map from the Location )
STEP-4 DATASET NAME ( LOGFILE NAME )
8/13/2019 18 Introduction to Genex Assistance
6/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
6
Opening a New Project
8/13/2019 18 Introduction to Genex Assistance
7/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
7
Project Path to Save It
8/13/2019 18 Introduction to Genex Assistance
8/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
8
Log file Name
8/13/2019 18 Introduction to Genex Assistance
9/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
9
ANALYSISLOG FILE IMPORTING
Step 1 Select a dataset from the Project tab in the navigation
view
Step 2 Right-click the dataset and choose Import Test Data
Import GENEX Probe on the shortcut menu
Step 3 In the Import GENEX Probe log File as shown below
8/13/2019 18 Introduction to Genex Assistance
10/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
10
Import the Type of Log File
8/13/2019 18 Introduction to Genex Assistance
11/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
11
CLICK BROWSE FOR
LOGFILE LOCATION
8/13/2019 18 Introduction to Genex Assistance
12/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
12
COMBINE DATA ANALYSIS
ASSISTANCE CAN SUPPORT IMPORTING MORE THAN ONE LOG
FILE AS IT COMBINES THESE DEVICES AND RE-ANALYZE THE
EVENTS
Step 1 Select a dataset from the Projecttab in the navigation view
Step 2 Choose Dataset> Combine Device> Combine UE
Step 3 Select multiple devices from PreCombinein the displayed
Combine Device
8/13/2019 18 Introduction to Genex Assistance
13/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
13
8/13/2019 18 Introduction to Genex Assistance
14/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
14
New Combined Log file
8/13/2019 18 Introduction to Genex Assistance
15/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
15
8/13/2019 18 Introduction to Genex Assistance
16/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
16
IMPORTING THE MAP DATA
VECTOR
PLACES
CLUTTER
Step 1 Select the Map Layer Window and right click.
Step 2 Select the location for the data to import.
8/13/2019 18 Introduction to Genex Assistance
17/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
17
Layer Control
8/13/2019 18 Introduction to Genex Assistance
18/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
18
Filtering Test Data
The Assistant can filter the imported data. This feature is capable of
comparing the data and executing some simple logical calculations.
To filter test data, perform the following steps:
Step 1 Select a dataset from the Project tab in the navigation view.
Step 2 Choose Dataset > Filter Imported Data
8/13/2019 18 Introduction to Genex Assistance
19/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
19
8/13/2019 18 Introduction to Genex Assistance
20/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
20
Select the Desired Filter
Click on Insert
Click on Excute
8/13/2019 18 Introduction to Genex Assistance
21/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
21
Introduction to Engineering Parameters
Engineering parameter fields
Field RemarksWhether Mandatory to BeFilled In
Longitude Longitude (decimal) YesLatitude Latitude (decimal) Yes
Azimuth Azimuth (C) No
Down Tilt Down tilt angle (C) No
E-Down Tilt Embedded down tilt angle (C) No
M-Down Tilt Mechanical down tilt angle (C) No
Ground Height Antenna ground height No
Altitude Antenna altitude No
8/13/2019 18 Introduction to Genex Assistance
22/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
22
Perform the following steps to import Engineering Parameters
Step 1 Select a dataset from the Projecttab in the navigation view.
Step 2 Choose Dataset> Import Engineering Parameter, andselect WCDMAor GSMbased on the test data.
Step 3 In the displayed dialog box, perform the following operations
Open the Excel file for saving the engineering parameters.
Select the sheet for displaying the engineering parameters.
Step 4 Click OK.
8/13/2019 18 Introduction to Genex Assistance
23/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
23
If all the fields in the sheet can match the parameters
the Assistant automatically imports the engineering parameters
If no field in the sheet can match the parameters
Step 5 Match the missing engineering parameter fields one by one.
For details, refer to description of button functions
Step 6 Click the button to import the data.After the data is imported, the site data is automatically
displayed on the map.
8/13/2019 18 Introduction to Genex Assistance
24/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
24
Step:01 Click on Dataset Name
Step:02
Select Type
8/13/2019 18 Introduction to Genex Assistance
25/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
25
Step:03 Open the Table
Step:04 Import the Excel file
8/13/2019 18 Introduction to Genex Assistance
26/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
26
Engineering Parameters DisplayEngineering Parameters Display
8/13/2019 18 Introduction to Genex Assistance
27/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
27
STEPS TO OPERATE ASSISTANT
3. Consolidated log file for
Different test
4. Analyze Report
5. Display Report on map
8/13/2019 18 Introduction to Genex Assistance
28/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
28
STEPS TO OPERATE ASSISTANT
6. Show Legends
7. Show vectors (layer control)
8/13/2019 18 Introduction to Genex Assistance
29/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
29
STEPS TO OPERATE ASSISTANT
8. Export Tab file
8/13/2019 18 Introduction to Genex Assistance
30/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
30
DRIVE TEST PLOTS
RX LEVEL PLOT
RXLEVEL FULL
RXLEVEL SUB
8/13/2019 18 Introduction to Genex Assistance
31/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
31
8/13/2019 18 Introduction to Genex Assistance
32/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
32
RX QUALITY PLOT
RX QUAL FULL
RX QUAL SUB
8/13/2019 18 Introduction to Genex Assistance
33/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
33
8/13/2019 18 Introduction to Genex Assistance
34/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
34
OTHER DIFFERENT TYPEOF PLOTS
8/13/2019 18 Introduction to Genex Assistance
35/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
35BCCH PLOT
8/13/2019 18 Introduction to Genex Assistance
36/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
36BSIC PLOT
8/13/2019 18 Introduction to Genex Assistance
37/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
37FER PLOT
8/13/2019 18 Introduction to Genex Assistance
38/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
38C/I PLOT
8/13/2019 18 Introduction to Genex Assistance
39/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
39HANDOVER PLOT
8/13/2019 18 Introduction to Genex Assistance
40/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
40
GSM DRIVE TEST STATISTICS
GENEX ASSISTANCE CAN PROVIDE THE DETAIL
REPORT OF THE DRIVE TEST
Report: WCDMA Scanner Neighbor Cell
Report: WCDMA Scanner Handover Statistic
Report: WCDMA UE Call Setup
Report: WCDMA UE Call Statistics
8/13/2019 18 Introduction to Genex Assistance
41/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
41
Report: WCDMA UE Call Timing Analysis
Report: WCDMA UE Crossingtable HSDPA
Report: WCDMA UE RRC Setup Statistics
Report: GSM Drive Test Statistics
Report: GSM UE Call Statistics Analyse
Report: GSMHandover Statistic
8/13/2019 18 Introduction to Genex Assistance
42/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
42
8/13/2019 18 Introduction to Genex Assistance
43/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
43
GSM DRIVE TESTSTATISTICS
The GSM Drive Test Statisticsreport provides the statistics on RXlevel,
voice quality, and so on, as listed in Table
Item Description
RxLev RX level in connected state
BCCH RxLev RX level in connected or idle state
RxLev as Distance Distance values for RX level > 90 dBm and RX level < 90 dBm
RxQual Statistics on quality and distance
TA Number of data points in each TA scope
Call Setup Time Number of data points in each scope of call setup duration as per call
8/13/2019 18 Introduction to Genex Assistance
44/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
44
RxLev_Sub(dBm) Distance(km) %Total
CountAvg
-70 to -10 10.90 60.22 % 3152 -59.30
-80 to -70 5.55 30.66 % 1861 -75.06
-90 to -80 1.52 8.40 % 548 -83.48
-100 to -90 0.11 0.61 % 33 -92.67-120 to -100 0.03 0.17 % 12 -101.00
Total 18.10 5606 -67.18
RxLev_Sub(dBm)
8/13/2019 18 Introduction to Genex Assistance
45/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
45
RxQual sub Count % Distance(km) %
7 153 2.73 % 0.79 4.35 %
6 146 2.60 % 0.60 3.33 %
5 143 2.55 % 0.62 3.45 %
4 157 2.80 % 0.62 3.40 %
3 192 3.42 % 0.92 5.11 %
2 121 2.16 % 0.47 2.61 %
1 203 3.62 % 0.72 3.99 %
0 4491 80.11 % 13.35 73.77 %
Total 5606 18.10
RxQual_Sub
8/13/2019 18 Introduction to Genex Assistance
46/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
46
TA Count %
32 to 63 0 0.00 %
10 to 32 0 0.00 %
5 to 10 0 0.00 %
4 to 5 0 0.00 %
3 to 4 5 0.09 %
2 to 3 41 0.74 %
1 to 2 688 12.47 %
0 to 1 4785 86.70 %
Average 0.14
Number of data points in each TA Scope
8/13/2019 18 Introduction to Genex Assistance
47/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
47
Call Setup Time (Alerting - ChannelReq )
Time Count % Avg
0s
8/13/2019 18 Introduction to Genex Assistance
48/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
48
RxQualCall Setup Time
TA
RxLev_Sub + RxLev_Idle(dBm)
REPORTS IN DEATAIL
8/13/2019 18 Introduction to Genex Assistance
49/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
49
GSM MS Call Analysis
GSM MS Call Statistics
GSM MOS Statistics
REPORTS IN DEATAIL
8/13/2019 18 Introduction to Genex Assistance
50/50
Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential
TH NK YOU