2014 A Skills
Mine Rescue Problem
Mine Rescue Statement 2014 A
• Welcome to the Happy Go Lucky Mine.
This is a high wall mine with a history of water and bad roof conditions. This mine has one unit operating. We have a day shift and a second shift which rotates every two weeks. Midnight shift is a maintenance shift. This mine generates its power from a diesel generator, which breaks down two or three times a week. The generator has been broke down, but it is running at the present time. I received a call from the mechanic on the unit. He stated that there was a problem on the unit ,and then we lost communication. We have had no further contact from the unit. There is power to the fresh air base. All power in by the fresh air base is off The fan is a blowing fan, and is on another power source. The fan is running, but may be turned off and on as needed. The fan has been examined and is being monitored. The map is up to date. We do not know how many people are underground. The tag board fell off the wall and all the tags are on the floor. That is all the information I have at this time.
Mine Rescue Problem
• 2014 Skills Problem
Make the mine in its entirety, where safe to do so. Account for all missing person, and bring all life persons to the Fresh air base,
Face Face
B
Face
BCBC
BC
LC
BO
X Battery Scoop
D RA
Field Map
Door Open
X One block knocked out
BC
5% CH4 4 PPM CO 12.9% O2
8 timbers X
X Roof Bolter
X Borehole
X person
D closed
Water roofed
5.0% CH4 6 PPM CO 19.2% O2
Water roofed
Ankle deep water
5% CH43 PPM CO19.1% O2
XXXXXXXXXXXX caved
Unsafe Roof
.5% CH4 2 PPM CO 18.5% O2
X permissible pump
X 150’ of power cable and discharge line
BC
Blowing fan
pump switch off
X
Fan switch on
X
Harden roomAirtight with door shut
Water roofed
Purge Valve
X
D
BO
Briefing officer Map
Door Open
BC
X permissible pump
X 150’ of power cable and discharge line
BC
Blowing fan
pump switch off
X
Fan switch on
X
Harden roomAirtight with door shut
BO
Team Map
Door Open
BC
X permissible pump
X 150’ of power cable and discharge line
BC
Blowing fan
pump switch off
X
Fan switch on
X
Harden roomAirtight with door shut
Patient Statement
RA
Help get me out
Patient Statement Barricade in #2
Help get me out
Patient Statement Barricade in #3
Help get me out
Face Face
B
Face
BCBC
BC
LC
BO
X Battery Scoop
D RA
2014 SIC Skills Handout Map
Door Open
BC
X Roof Bolter
X Borehole
X person
D closed
Water roofed
Water roofed
Ankle deep waterXXXXXXXXXXXX caved
Unsafe Roof
X permissible pump
X 150’ of power cable and discharge line
BC
Blowing fan
pump switch off
X
Fan switch on
X
Harden roomAirtight with door shut
Water roofed
D
X
Purge valve
Face Face
B
Face
BCBC
BC
LC
BO
X Battery Scoop
D RA
First Vent
Door Open
X One block knocked out
BC
5% CH44 PPM CO 12.9% O2
8 timbers X
X Roof Bolter
X Borehole
X person
D closed
Water roofed
5.0% CH4 6 PPM CO19.2% O2
Water roofed
Ankle deep water
CH4 5%3 PPM CO 19.1% O2
XXXXXXXXXXXX caved
Unsafe Roof
.5% CH42PPM CO 18.5%O2
X permissible pump
X 150’ of power cable and discharge line
BC
Blowing fan
pump switch off
X
Fan switch on
X
Harden roomAirtight with door shut
If they pump # 2 and explore, there Is enough building material to isolate number 2 entry to wing # 1
Water roofed
Face Face
B
Face
BCBC
BC
LC
BO
X Battery Scoop
D RA
Team stop Map
Door Open
X One block knocked out
BC
5% CH4 4 PPM CO 12.9% O2
8 timbers X
X Roof Bolter
X Borehole
X person
D closed
Water roofed
5% CH4 6 PPM CO 19.2% O2
Water roofed
Ankle deep water
5% CH4 3 PPM CO 19.1% O2
XXXXXXXXXXXX caved
Unsafe Roof
.5% CH4 2 PPM CO18.5% O2
X permissible pump
X 150’ of power cable and discharge line
BC
Blowing fan
pump switch off
X
Fan switch on
X
Harden roomAirtight with door shut
1, 2 or 3
1, 2 or 3
5 If you found the gas outby in #3 entry you will have follow your containment in 3 # entry
1, 2 or 3
4
6
7
8
9
Pump waterPump water
Pump waterWater roofed
Once the timbersare found, youRetreat to the person in # 1
Face Face
B
Face
BCBC
BC
LC
BO
X Battery Scoop
D RA
Second Vent
Door Open
X One block knocked out
BC
5% CH4 4 PPM CO 12.9% O2
8 timbers X
X Roof Bolter
X Borehole
X person
D closed
Water roofed
5.0% CH4 6 PPM CO 19.2% O2
Water roofed
Ankle deep water
5% CH4 3 PPM CO 19.1% O2
XXXXXXXXXXXX caved
Unsafe Roof
.5% CH42 PPM CO 18.5% O2
X permissible pump
X 150’ of power cable and discharge line
BC
Blowing fan
pump switch off
X
Fan switch on
X
Harden roomAirtight with door shut
1 or 21 or 2
3 4
5
6
7
8
Water roofed
This build is needed If you have pumpedThe water in # 3
At the end ofThe problem props must beset in theUnsafe in #3People may still be missing
open
Face Face
B
Face
BCBC
BC
LC
BO
X Battery Scoop
D RA
Judges Map
Door Open
X One block knocked out
BC
5% CH44 PPM CO12.9% O2
8 timbers X
X Roof Bolter
X Borehole
X person
D closed
Water roofed
5.0%CH4 6 PPM CO 19.2% O2
Water roofed
Ankle deep water
5% CH43 PPM CO 19.1% O2
XXXXXXXXXXXX caved
Unsafe Roof
.5% CH4 2 PPM CO 18.5% O2
X permissible pump
X 150’ of power cable and discharge line
BC
Blowing fan
pump switch off
X
Fan switch on
X
Harden roomAirtight with door shut
BO
Briefing officer Map
Door Open
BC
X permissible pump
X 150’ of power cable and discharge line
BC
Blowing fan
pump switch off
X
Fan switch on
X
Harden roomAirtight with door shut