ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 1
Catalogue May 2014
2
Factory
Microdent Commercial
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 3
Microdent Implant System is a company dedicated since 1983 to deve-lop, manufacture and marketing oral implant systems. Microdent implant systems of external and internal prosthesis connection have been desig-ned and developed to facilitate and resolve the important medical work of professionals who require material more accurate and higher quality.
Always ensuring the customer satisfaction, Microdent offers all guaran-tees of quality and service that are supported by its long and ascending career in the field of oral implantology.Microdent has modern facilities equipped with the most innovative technology, which makes the Company one of the pioneers in research and implants manufacturing. Patents obtained by Microdent products demonstrate the continued commitment of the company to research. Microdent has shown a special concern in the area of training from the beginning, organizing usually courses, seminars and workshops to close implant knowledge and tools to professionals for success in their work with patients. These courses are performed in the national territory and also at the Company facilities, where there is an auditorium and practice rooms.
Microdent has a very active presence at trade shows and conferences, both nationally and internationally level, where it participates with stands, seminars and product presentations. This promotional activity and also its website provide update information about events, news and products, among others, contributing to consolidate its image as a premier level company.
Microdent Implant System SL meets the standards ISO 13485:2003 and Eu-ropean Directive 93/42/EEC about Medical Devices.
4
Microdent presents some novelties recently added to Microdent range products with a brief description of the most remarkable features.
NEW PRODUCTS
In our www.MICRODENTSYSTEM.com website you will find the most recent updates.
Particularly indicated for correction of angulations. It makes easier to align and fix in vertical position the tube of the corrector from an eventual unpara-llelism of previous placed implants.They are used for definitive prosthesis using the overcast technique.For more information, get in contact with us.
SEMICALCINABLEORIENTABLE
Mkpro, specially designed for post extraction tooth replacements, allows to fix the implants with an optimal stability and parallelization, closing the hole surgical alveolus area. Available in several diameters and lenghts.
Mkpro4 new range of extra-short dental implants with only 4mm length and available in Ø 6, Ø 7 y Ø 8mm for limited vertical bone height cases. Recom-mended as an alternative for maxillary sinus lift or in order to avoid vital structures such as inferior alveolar nerve.
For more information, get in contact with us.
NEW IMPLANTSMKpro & MKpro4
MK Series
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 5
NEW PRODUCTS
NEWS KITSMEMBRANE FIXING & BONE GRAFTINGMicrodent presents 2 new surgical kits for maxillofacial and oral surgery. - 1 osteosynthesis micro-screws kit for bone blocks fixing. - 1 membrane attachment and bone grafting material kit.(for more information, get in contact with us)
Microdent presents this book made in cooperation with the University Rey Juan Carlos of Madrid with the intention of being a very interesting learning and practical tool for all implantology professionals. (for more information, get in contact with us)
IMPLANTOLOGÍA 2.0 An open book
NEW IMPLANTSMKpro & MKpro4
MK Series
6
PRODUCT PRESENTATION
IMPLANT CATALOGUES MICRODENT ELITE
PRODUCT GUIDES
OTHER CATALOGUES
DIGITAL INFORMATION
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 7
PATENTES
GENIUS IMPLANTS
The Microdent implant System is protected with several invention patents and utility models We would like to highlight the following ones:
Microdent registered trademark nº 1742465
Patent in Spain for bone expanders nº 9602250
Patent in USA for bone expanders nº 6146138 Patent in Europe for bone expanders nº 023801558
Patent for Micro-Pik prosthesis fixing system nº 9800394
Patent for transmucous dental implant nº 20002497
Patent for overdenture ball-and socket joint nº 20002545
Security device for surgery nº 200102649
Patent for security surgical instrument nº 200102769
Patent for bicortical provisional implant nº 200102914
Patent for Trylogic implant nº 200200087
Patent for improved dental implant nº 200201614
Patent for adjustable overdenture retention system nº P200300602
Patent for biomechanical union system nº 200402082
Patent for melatonine using for osseous regeneration, for human and veterinarian using as an active product nº 200203054
Patent for Capitel Pillar on prosthetic angled correction nº 200701563
Patent for Osscilia. Pendulous spherical retainer for overdenture. nº 200702213
Patent for Novatech. Angled fixation system. nº P200503064
Patent dental implant nº 200700408
Patent MRT dental implant with prosthetic union nº 200701138
Patent Rodas system for biomechanical union system between implants and prosthesis nº 200402082
Patent for Cortical-Fix for sinus cavity conformation nº 200800195 Retainer key for implants nº 200703251 Patent device for dental prosthesis fixation nº 200300041 Patent Orthodontic implant nº 200500306 Patent MV implant for insertion without drill nº 200801197
Bone expanders for Guided Dental Surgery nº 201031083/ot
Dental implants disparallelism prosthetic corrector nº 201030002/5
8
INDEXGENIUS CATALOGUE
GENIUS IMPLANTS
GENIUS-V IMPLANTS
SURGICAL PROTOCOL
SURGICAL INSTRUMENTAL
SCREWDRIVERS
IMPLANTOLOGY ENGINES
SURGICAL KITS
BONE EXPANSION
SINUS LIFT. CORTICAL-FIX
IMPRESSION TAKING
HEALING PILLARS
10
11
12
16
33
22
15
34
37
19
THREADED PROSTHESIS
OVERCAST PROSTHESIS
OVERDENTURES PROSTHESIS
PROVISIONAL IMPLANTS
CEMENTED PROSTHESIS
25
28
30
39
21
32
20
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 9
IMPLANTOLOGICAL SYSTEM
GENIUSWITH INTERNAL PROSTHETIC CONNECTION
10
Implant system of internal connection with hexagonal ribbed cone allowing a perfectsealing of the implant-prosthesis junction in just a piece and also creating anarea for biological growth on the surface by its cone design on the emergence zonewhich predict a reduction of gingival recession.Several core diameters of Genius System implants have dimensionally the sameinternal connection, being the sole system which allows all abutments exchange tomake the prosthesis.Genius and Genius V implants are presented distinguished for its use in traditional surgery protocols (drilling protocols), guided surgery (drilling protocols with surgical guide), guided expansion (protocols based on expander use with surgical guide).
GENIUS IMPLANTSIMPLANTOLOGICAL SYSTEM WITH INTERNAL PROSTHETIC CONNECTION
All implants external surface is etched in all their length, it doesn’t exist Genius version with polished zone. i
Colour code identification:Bronze color code is associated with the platforms from Genius.
Moreover, with added convenience that you only need an screwdriver to fix GNTRHC prosthesis retention screw.
Ø 3,50 platform
L
8
10
12
14
16
18
GN3508AT
GN3510AT
GN3512AT
GN3514AT
GN3516AT
GN3518AT
GN4008AT
GN4010AT
GN4012AT
GN4014AT
GN4016AT
GN4018AT
GN4508AT
GN4510AT
GN4512AT
GN4514AT
GN4516AT
GN4518AT
GN5008AT
GN5010AT
GN5012AT
GN5014AT
GN5016AT
-
Available cores
Ø 3,50 Ø 4,00 Ø 4,50 Ø 4,50
Available cores Available cores Available cores
Ø 4,00 platform Ø 4,50 platform Ø 5,00 platform
Ø 3,50 Ø 4,00 Ø 4,50 Ø 5,00
Ø 3,50 Ø 4,00 Ø 4,50 Ø 5,00
Connection details
L
M1,80
0,92mm
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 11
GENIUS V IMPLANTSFOR SURGICAL TECHNIQUE WITHOUT DRILLING
IMPLANT WITH INTERNAL CONNECTION EXPANSIVE CORE As a complement to Genius Implant System, Microdent boosts his internal connection implant range, by adding the benefits provided by expansive core, in order to perform minimally invasive surgery, because, depending on bone density and quality, implant can be inserted in narrow ridges by using 1,80 pilot drill and later using the expanders, if necessary.
Surgical protocolImplant fixation, once cortical drilling is made to 5mm maximum depth (drill first mark), should be performed with expander use only to form dimensionally the alveolus into perspective and get an excellent implant primary retention. Genius-V implants are pla-ced with great facilitate in II, III and IV bone types. In I bone type, alveolus preparation can justify 1,80mm drill use at a 3mm drilling depth less than length of implant to be inserted. We recommend using Genius V implants of length greater than 12mm.
Clinical advantages
· It shortens and simplifies the surgery time.
· Without drilling passage, bone heating risk is avoided.
·Suitable for use in guided expansion
·Its conical design makes expansive and gradual effect in the insertion.
· Great self-tapping capacity and excellent primary retention.
· Indicated for atrophy cases.
·Ideal for tricortical anchor (in addition to the bone tables in maxillary sinus floor, nasal cavity or mandibular inferior cortical
Additional instrumental· Short or long tap drill· Expanders nº 1, nº2, nº3, nº4 and nº5· Dilatators nº2, nº3, nº4 and nº5
For mor information about required instru-mental ask for our Bone Expansion catalogue.i
Ø 4,50Ø 4,00
Ø 1,50 Ø 1,60 Ø 1,60
Ø 3,50
L
Ø 3,50 platform
L
10,0
12,0
14,0
16,0
18,0
GNV3510AT
GNV3512AT
GNV3514AT
GNV3516AT
GNV3518AT
GNV4010AT
GNV4012AT
GNV4014AT
GNV4016AT
GNV4018AT
GNV4510AT
GNV4512AT
GNV4514AT
GNV4516AT
GNV4518AT
GNV5010AT
GNV5012AT
GNV5014AT
GNV5016AT
-
Available cores
Ø 3,50 Ø 4,00 Ø 4,50 Ø 5,00
Available cores Available cores Available cores
Ø 4,00 platform Ø 4,50 platform Ø 5,00 platform
Ø 5,00
Ø 1,60
12
SURGICAL PROTOCOLFOR GENIUS IMPLANTSDRILL FOR FIX IMPLANTS (EXTERNAL IRRIGATION)Made on high hardness surgical stainless steel, they assure a perfect cut during surgical drilling.
Tip milling drill for the alveolus *Drill to cut the cortex Initial drills
FP10 FC20C FP1812FC20L FP1817Short ShortLong Long
1,80
1,801,90
1,90
Depth markings to: 8, 10, 12, 14 y 16 mm.
i
Pilot drillØ
Ø 2,50 -
Ø 2,80 F1828*
Ø 3,00 -
Ø 3,20 F1832*
Ø 3,50 F1835*
Ø 3,80 -
Available diameters
Short drillExtra short drill Long drill
Ø 3,20**Ø 1,80*
810121416
8mm
F350L
F380L
F320L
F300L
F280L
F250L
F350CF350EC
-
-
-
-
- F380C
F320C
F300C
F280C
F250C
68
Ø 4,20 - F420EC F420 -
Ø 4,50 - F450EC F450 -
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 13
DRILLS TO FIX IMPLANTS (INTERNAL IRRIGATION)
Drills with adjustable stop (internal irrigation)
This type of drill enables the user to accurately control the alveolus drilling depth.Long drills can be adjusted from 8mm to 16mm and short drills from 8mm to 12mm.This adjustment of the cutting depth is very simple to do thanks to some indelible markson the drill. The stop is regulated by the screwdriver MH120.
Drill extenderTo connect contra-angle. With internal irrigation.
EXFRE Drill extender
Short LongØ
Ø 1,80 FT180C
Ø 2,80 FT280C
Ø 2,50 FT250C
Ø 3,20 FT320C
Ø 3,00 FT300C
Ø 3,50 FT350C
Ø 3,80 FT380C
Drill diameters
8 mm
8 mm
Ø 4,20 *FT420C
Ø 4,50 *FT450C
(*) FT420 y FT450 drills the first depht mark is located 6mm.
FT180L
FT250L
FT280L
FT300L
FT320L
FT350L
FT380L
*FT420L
*FT450L
14
SURGICAL PROTOCOLDRILLING SEQUENCE FOR MICRODENT GENIUS
This recommendations are only for guidance and must be tailored to the type and quality of the bone where the implant is going to be inserted. * Depending on bone quality.i
GUIDANCE
Drill step 1
Cortical drill
Ø 3,50 platform Ø 4,00 platform Ø 4,50 platform Ø 5,00 platform
Ø Implant core
Drill step 2
Initial drill
Drill step 3
Intermediate drill
Drill step 4
Intermediate drill
Drill step 5Final drill(depending on bone quality)
FC20
FP1812 / FP1817
-
F250C
*F300C *F350C *F380C *F450C*F280C
FP1812 / FP1817
-
F280C
*F320C *F350C *F420C
F280C F280C
FP1812 / FP1817 FP1812 / FP1817
F320C F350C
FC20 FC20 FC20
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 15
SURGICAL KIT (Ref. KC)
SPECIAL SURGERY KIT (Ref. SKC)
BASIC KIT (Ref. BK)
Available while supplies last.
Box composed of: · Rattle spanner · Expanders nº 1,2,3,4 y 5 · Key to immobilize the metal implant horder· 1,20 fixed hexagonal screwdrivers and groove longs ones. · 1,20 Short and long screwdrivers for torque wrench and rattle spanner· Slope guides (4 units)· Short and long adaptor for implants fixation.· Metal implant holder extender.· Deep meter.· Thread cleaner.· Short and long drill for cortical.· Fresa perforación cresta · Crest perforation drill.· F1828, F1832, F3545 guiding drill
· Circular saw · Short and long pilot drill.· Ø 2,50 and Ø 3,00 short and long surgical drills. · Ø 2,80, Ø3,50, Ø 3,20 and Ø 3,80 short and long surgical drills · Ø 3,50 and Ø 5,00 trephines · Short and long circular scalpel for Ø 3,50 4,00 and 4,50· Titanium tong· Contra-angle spanner for metal implant holders· Inner contrangle key to implant insertion· Key to unlock conical anchor-age between implant and pillar.
Box composed of: · Cortical drill· Short pilot drill· Long pilot drill· Ø 2,50 drill· Ø 2,80 drill· Ø 3,00 drill· Ø 3,20 drill . Ø 3,50 drill . Ø 3,80 drill . Ø 4,20 drill
· Lean guide (2 units) · 1,20 screwdriver (3 units)· Implant holder adaptor· Implant extender· Contra-angle implant holder spanner· Rattle spanner· Inner contrangle key to implant insertion
i
Box composed of: · Cortical drill· Pilot drill· Ø 2,80 drill· Ø 3,20 drill· Ø 3,50 drill· Ø 3,80 drill· MH120 screwdriver (2 units)· Adaptor· Extender· Engine key· Inner key
SURGICAL KITS
16
SURGICAL INSTRUMENTALCONTRA-ANGLE SPANNER FOR METAL IMPLANT HOLDERS
INNER CONTRANGLE KEY TO IMPLANT INSERTION
KEY TO UNLOCK CONICAL ANCHOR-AGE BETWEEN IMPLANT AND PILLAR
ADAPTORS TO IMPLANT FIXATION EXTENDER FOR METAL IMPLANT HOLDERS
This is used to fix implants with a implant metal holder and it is used directly on this holder. This tool works with the whole range of platforms.
This key avoids implant carrier use, improving vision field during implant insertion. Key tip has been designed to adjust perfectly to implant inner cone.
It is used by threading it to prosthesis implant inte-rior (available in conic pillars, semi calcinables and overcast pillar) in those cases requiring pillar can’t be removed, even when retention screw has been removed. It will be unlocked simply threading this key in pillar interior.
LC44 GNLLIC GNLLDS
For interdental and difficult access zones. They are used to fix implants with implant metal holders and it is applied directly onto the holder itself.
Ø 3,80 mm
Ø 3,80 mm
L 16mmL 9 mm
Ø 5,8mm
17mm
Ø 5,8mm
10mm
Ø6,5mm
CGNAFC ACC44CGNAFL ACL44
Ø Platform Ø Platform3,50mm / 4,00mm / 4,50mm 3,50mm / 4,00mm / 4,50mmShort ShortLong Long
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 17
SURGICAL INSTRUMENTALKEY TO IMMOBILIZE HOLDER IMPLANTIt is an instrument very practical and precise to retain and unblock the implant holder at the fix-ing implant moment . It is used in combination with torque spanner in situation where implant primary retention is weak and implant can turn and lose depth stablished position.
RATCHET SPANNER
TORQUE SPANNER ADJUSTABLE TORQUE SPANNER
This spanner must be used carefully because it does not have any strength limiting device.
This spanner is adjusted in such a way as to pre-vent exceeding the torque of 20 or 30 ncm.
This spanner allows to adjust the torque from 20ncm to 70 ncm, just turning its wheel up to required torque.
20 newtons LD2
LD330 newtons
LLDP
LD1
LDR2070
EXTRA ORAL SPANNER
To place implants from outside of the oral cavity.It adapts to implant holder square.
LLEO7 mm
Mini kit composed by a torque wrench, an adjust-ing wrench and a lubricant tube.
18
SURGICAL INSTRUMENTAL
DEPTH GAUGE LEAN GUIDE
INTERNAL THREAD CLEANERUsed for checking implant internal thread if necessary.
Used for checking drilling depth. With depth marks from 8mm to 16mm.
This is used to control and guide the direction of the surgical alveolus.
LRI180
Ø Platform 3,50mm / 4,00mm / 4,50mm
CIRCULAR SCALPELS
Used for a circular and non traumatic gum cut y atraumático in order to discover the bone for its further drilling and implant placing or for localize the implant in a el second surgery in order to place healing pillars.
8 mm
16 mm
3,50 BC355C
BC400C
BC450C
BC355L
BC400L
BC450L
4,00
4,50
Ø Core implant Short Long
MP1822
GI1828 1,8 2,8
GI3245 3,2 4,5
ØA ØB
1,80 mm
Maximum depth
12 mm
12 mm
A
B
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 19
AESTHETIC HEALING PILLAR MINI
The aesthetic healing pillar MINI is indicated to fix overdentures with the Osscilia System.
For prosthesis that are screwed with Capitel pillar, the pillar must be Ø 5,0mm.
These pillars have an aesthetic design in line with all Genius implants plat-form to adapt the soft tissue, extending the space of biological margin.Depending on the thickness of the gum it will be used a different heightThe abutments are fixed to the implant with the MH120 screwdriver.
AESTHETIC HEALING PILLARS
AESTHETIC HEALING PILLAR
GNPR4501GNPR5001GNPR5501
GNPCR3501
GNPR4502GNPR5002GNPR5502
GNPCR3502
GNPR4503GNPR5003GNPR5503
GNPR4504GNPR5004GNPR5504
GNPR4505GNPR5005GNPR5505
GNPR4506GNPR5006GNPR5506
GNPCR3503 GNPCR3504 GNPCR3505 GNPCR3506
Ø Plataform
Ø Plataform 3,5mm / 4,0mm / 4,5mm / 5,0mm
3,5mm / 4,0mm / 4,5mm / 5,0mmHeight. 1
Height 1
Height. 2
Height. 2
Height. 3 Height. 4 Height. 5 Height. 6
Height. 3 Height. 4 Height. 5 Height. 6
Ø Pilar
Ø Pillar3,5
4,55,05,5
hhhhh
Healing pillars diameter are 3,5, 4,5, 5,0 and 5,5 mm. Specified in reference.
i
i
i
hhhhh
2,60mmh
h
2,60mm
HEALING PILLARS
20
OPEN TRAY TECHNIQUE
CLOSED TRAY TECHNIQUE BALL SCREW
IMPLANT ANALOGUE
GNTCAHC
GNRI
CGNTCCH
GNTCAHLGNTCARC GNTUCAC GNTUCAL
CGNTCCR
GNTCARL
Ø Platform
Ø Platform
Ø Platform
Ø Platform
Short Long
3,5mm / 4,0mm / 4,5mm / 5,0mm
3,5mm / 4,0mm / 4,5mm / 5,0mm
3,5mm / 4,0mm / 4,5mm / 5,0mm
3,5mm / 4,0mm / 4,5mm / 5,0mm
Implant analogue
Hexagonal carrier
Hexagonal carrierHexagonal carrier
Circular carrier
Circular carrierCircular carrier Screw Screw
The transfers for impression closed-tray are used with the connecting screw TUC18 which is included in the kit.
i
GNTUCB
Ball screw
Metallic protector to avoid the entry of resin.It is used as an alternative to the plastic protector and the connec-ting screw.
Impression removing is made with transfers. Attachment screw is removed with MH120 screwdriver.
When transfers have no retention they are not housed in the impression, and they must be further replaced. Attachment screw is removed with MH120 screwdriver.
Protector for avoiding resin entry in screw housing
IMPRESSION TAKING SYSTEM
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 21
They are used to correct the eventual unparallelism of the implants.ANGLED PILLARS
CONICAL PILLAR WITH FLAP CONICAL PILLAR WITHOUT FLAP
Pillars diameter are 4,5, 5,0 y 5,5 mm. Specified in reference.
Pillars diameter are 3,8, 4,3 y 4,8 mm. Specified in reference
i
i
GNPCCP4501HGNPCCP5001H GNPCCP5501H
CGNPAE154501HCGNPAE155001HCGNPAE155501H
CGNPAE154502HCGNPAE155002HCGNPAE155502H
GNPCCP4502HGNPCCP5002H GNPCCP5502H
GNPCCP4503HGNPCCP5003H GNPCCP5503H
GNPCCP4504HGNPCCP5004H GNPCCP5504H
GNPCCP4505HGNPCCP5005H GNPCCP5505H
GNPCCP4506HGNPCCP5006H GNPCCP5506H
GNPCCP4501RGNPCCP5001RGNPCCP5501R
GNPCSP38HGNPCSP43HGNPCSP48H
CGNPAE204501HCGNPAE205001HCGNPAE205501H
CGNPAE204502HCGNPAE205002HCGNPAE205502H
CGNPAE254501HCGNPAE255001HCGNPAE255501H
CGNPAE254502HCGNPAE255002HCGNPAE255502H
GNPCCP4502RGNPCCP5002RGNPCCP5502R
GNPCCP4503RGNPCCP5003RGNPCCP5503R
GNPCCP4504RGNPCCP5004RGNPCCP5504R
GNPCCP4505RGNPCCP5005RGNPCCP5505R
GNPCCP4506RGNPCCP5006RGNPCCP5506R
Height
Height
Ø Pillar Ø Pillar
Ø Pillar
4,5 3,8
4,5
4,5
4,5
4,5
4,5
4,5
4,5
5,0 4,3
5,0
5,0
5,0
5,0
5,0
5,0
5,0
5,5 4,8
5,5
5,5
5,5
5,5
5,5
5,5
5,5
Height.1
Height. 1
Height. 2
Height. 2
Height.3
Height. 4
Height.5
Height.6
Ø Platform Ø Platform
Ø Platform
3,5mm / 4,0mm / 4,5mm / 5,0mm 3,5mm / 4,0mm / 4,5mm / 5,0mm
3,5mm / 4,0mm / 4,5mm / 5,0mm
Hexagonal
15º Angulation
Circular Circular
20º Angulation 25º Angulation
Ángulo20º
Ángulo15º
Ángulo25º
h
hh2,60mm
Detail pillar insertioninto the implant
Indicated for be used in unitary and multiple metal-ceramics prosthesis.They are threaded to implant by means of GNTRHC screw with DL120.They are provided with a pillar inner cone adjustment unlock with implant.
CONICAL PILLARS
CEMENTED PROSTHESISCONICAL AND ANGLED PILLARS
22
Diameter pillar is 4,5, 5,0 y 5,5 mm. Speci-fied in reference.i
Circular
Hexagonal
GNPCI4501RGNPCI5001RGNPCI5501R
GNPCI4501HGNPCI5001HGNPCI5501H
GNPCI4502RGNPCI5002RGNPCI5502R
GNPCI4502HGNPCI5002HGNPCI5502H
GNPCI4503RGNPCI5003RGNPCI5503R
GNPCI4503HGNPCI5003HGNPCI5503H
GNPCI4504RGNPCI5004RGNPCI5504R
GNPCI4504HGNPCI5004HGNPCI5504H
GNPCI4505RGNPCI5005RGNPCI5505R
GNPCI4506RGNPCI5006RGNPCI5506R
GNPCI4505HGNPCI5005HGNPCI5505H
GNPCI4506HGNPCI5006HGNPCI5506H
Ø Platform
Ø Platform 3,5mm / 4,0mm / 4,5mm / 5,0mm
3,5mm / 4,0mm / 4,5mm / 5,0mmHeight. 1
Height. 1
Height 2.
Height. 2
Height. 3
Height. 3
Height. 4
Height.4
Height. 5 Height. 6
Height.5 Height.6
Ø Pillar
Ø Pillar
4,5
4,5
5,0
5,0
5,5
5,5
h
h h
h
h
h
h
h
h h
h
Is screwed into the implant with hexagonal screw GNTRHC with DL120 screwdriver.
h
2,60mm
2,60mm
i
CEMENTED PROSTHESISINMEDIATE LOADING
Special conical pillar for being used during first surgical phase, easily cut and with excellent retention form cemented- threaded prosthesis.Impressions are taken over the pillar. Available in circular and hexagonal shape and in several highsThey are threaded to implant with GNTRHC screw by means of DL120 screw-driver.
INMEDIATE LOADING SYSTEM
CIRCULAR CONICAL PILLAR FOR MULTIPLE PROSTHESISUsed as a base in unitary provisional prosthesis retention
HEXAGONAL CONICAL PILLAR FOR UNITARY PROSTHESISUsed as a base in unitary provisional prosthesis retention
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 23
CGNZR4815 CGNZR4803
CGNDOM4XH CGNDOM4XR
Height 1,5
Hexagonal Circular
Height 3Ø Platform
Ø Platform
3,5mm / 4,0mm / 4,5mm / 5,0mm
3,5mm / 4,0mm / 4,5mm / 5,0mm
Ø Pillar
Ø Pillar
4,8
3,2
Zirconium pillar diameter is 4,8mm. Specified in reference.i
h h
Genius zirconium pillars are supplied cemented over metal sheath (Domo pillar) forming just a sole abutment.They can be mounted over the implant in any position. Available on circular and hexagonal shape.Supplied with relative retention screw (GNTRHC) an applied to implant by means of DL120 screwdriver.
STANDARD ZIRCONIUM PILLARS
CEMENTED PROSTHESISZIRCONIUM AND DOMO PILLARS
ZIRCONIUM PILLAR SET
Titanium connectors fixed to implant and used to personalized zirconium pillars.Supplied with relative retention screw (GNTRHC).
DOMO PILLARS
DOMO PILLAR SET
24
Pillar diameter is 4,5 mm. Specified in reference.i
Hexagonal
Circular
CGNPPR4501H
CGNPPR4501R
CGNPPR4502H
CGNPPR4502R
CGNPPR4503H
CGNPPR4503R
CGNPPR4504H
CGNPPR4504R
CGNPPR4505H CGNPPR4506H
CGNPPR4505R CGNPPR4506R
Ø Platform
Ø Platform
3,5mm / 4,0mm / 4,5mm / 5,0mm
3,5mm / 4,0mm / 4,5mm / 5,0mm
Height. 1
Height. 1
Height. 2
Height. 2
Height. 3
Height. 3
Height. 4
Height. 4
Height. 5 Height. 6
Height. 5 Height. 6
Ø Pillar
Ø Pillar
4,5
4,5
h
h
h
h
h
h
h
h
h
h
h
2,60mm
2,60mm
h
Those pillars prepare soft tissue conforming biological margins until defini-tive prosthesis pillar mounting. They are used as a support and provisional unitary or multiple prosthesis fixing.Available in circular and hexagonal shape and several highsThey are threaded to implant with GNTRHC hexagonal screw by means DL120 screwdriver.
PILLAR FORM PROVISIONAL PROSTHESIS
CEMENTED PROSTHESISPILLARS FORM PROVISIONAL PROSTHESIS
PROVISIONAL PILLARS
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 25
Circular
UTSLEC UTSTICP
FIXING KEY CAPITEL PILLAR CARRIERManual carrier makes easier the implant transport to the mouth and the initial threaded of the abutement. It adjusts to the cone of the Capitel pillar.
INSTRUMENTAL
Diameter pillar is 4,8mm. Specified in reference.i
CGNCAP4801R CGNCAP4802R CGNCAP4803R CGNCAP4804R CGNCAP4805R CGNCAP4806R
Ø PlatformHeight. 1 Height. 2 Height. 3 Height. 4 Height. 5 Height. 6Ø Pillar
4,8
h h h h h h
2,60mm
3,5mm / 4,0mm / 4,5mm / 5,0mm
Pillar issue for making up threaded multiples prosthesis.
Capitel pillar for threaded multiples prosthesis is un abutment which is fi-xed in implant platform forming an only one piece without any movement possibility in rotational way althout repetitive dismantling in prosthesis production tests, Capitel pillars can be exchanged without loosing position reference in impression taking.For placing in the implant, there is a UTSTICP carrier helping to pillar initial thread. Availables in variable hights to make easier gum margin and to calculate sthetic aspect.
CAPITEL PILLAR
THREADED PROSTHESISCAPITEL PILLARS
Capitel pillars seat platform allow an angle which exceed parallelisme 25º degrees between implants.
26
Instrumental, elements for impressions taking and prosthetic abutment, are the same as used for the straight Capitel pillar
Capitel pillar seat platform allows angulation up 35º.
CGNCAPA254801H CGNCAPA354801H
CGNCAPA254802H CGNCAPA354802H
Height
Height. 1
Height. 2
Ø Platform 3,5mm / 4,0mm / 4,5mm / 5,0mm25º Angulation 35º AngulationØ Pillar
4,8
4,8 Capitel pillar diameter is 4,8mm. Specified in reference.
i
UTSTICP
PositionerIt allows to determine easily the orientation of the abutement towards the implant.
Angled35º
Angled25º
h
i
ANGLED CAPITEL PILLARS
THREADED PROSTHESISCAPITEL PILLARS
Used in important implant disparallelism situations, it corrects angulations over 25°.Supplied in two angulations (25° and 35°) and in 1 and 2mm. highsIn prosthesis restoration over angled capitel pillars you use the same abutments used form straight Capitel pillars. To make easy pillar favorable orientation over the implant, there exist a posi-tiner supplied in angled pillar set.Angled Capitel pillar fixation over the implant is made with GNTRHC screw by means of DL120 screwdriver.
CAPITEL PILLARS
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 27
THREADED PROSTHESISABUTMENTS FOR STRAIGHT AND ANGLED CAPITEL PILLARS
Those abutments are common for Straight and Angled Capitel Pillar, except retention screw.
i
Short attachment screw for closed tray transfer
Long attachment screw for open tray transfer
UTSTU4XC UTSTU4XL
IMPRESSION TAKING
INSTRUMENTAL
Ø Platform
Ø Platform Ø Platform
Ø Platform
Ø Platform Ø Platform
Ø Platform
CopingConical pillar
Analogue for Capitel pillars for multiple prosthesis
Circular transfer
Retention screw
3,50mm / 4,00mm / 4,50mm
3,50mm / 4,00mm / 4,50mm 3,50mm / 4,00mm / 4,50mm
3,50mm / 4,00mm / 4,50mm
3,50mm / 4,00mm / 4,50mm 3,50mm / 4,00mm / 4,50mm
3,50mm / 4,00mm / 4,50mm
Circular
Circular Circular
Circular
Circular Circular
Circular
UTSTR
UTSTRA
(for Straight Capitel Pillar)
(for Angled Capitel pillar)
UTSCP4X
UTSPS4X UTSSC4X
UTSPC4X
UTSRI4X UTSTC4X
UTSPP4X
Tighten screwdriver for retention screws
MH120CAP
Pillar for provisional prosthesis Overcast pillar Semi calcinable RX25S
28
Is screwed into the implant with hexagonal screw TRLTR43L with DTOC160H screwdriver.
Semicalcinables diameter is 4,5, 5,0 y 5,5 mm. Specificated in reference.i
i
Indicated for correcting angulations around 20º as they allow easily to align and to fix over the vertical tube of the corrector, overcoming an eventual unparallelism of dental implants. They are used for defi-nitive prosthesis by casting technique.
ORIENTABLE SEMICALCINABLE
Hexagonal
Circular
CGNSCO45HCGNSCO50HCGNSCO55H
CGNSCO45RCGNSCO50RCGNSCO55R
Height Ø Pillar4,55,05,5
Ø Platform 3,5mm / 4,0mm / 4,5mm / 5,0mm Hexagonal Circular
CGNSC4501HCGNSC5001H CGNSC5501H
CGNSC4501RCGNSC5001R CGNSC5501R
CGNSC4502HCGNSC5002H CGNSC5502H
CGNSC4502RCGNSC5002R CGNSC5502R
CGNSC4503HCGNSC5003H CGNSC5503H
CGNSC4503RCGNSC5003R CGNSC5503R
CGNSC4504HCGNSC5004H CGNSC5504H
CGNSC4504RCGNSC5004R CGNSC5504R
CGNSC4505HCGNSC5005H CGNSC5505H
CGNSC4506HCGNSC5006H CGNSC5506H
CGNSC4505RCGNSC5005R CGNSC5505R
CGNSC4506RCGNSC5006R CGNSC5506R
Ø Platform
Ø Platform
3,5mm / 4,0mm / 4,5mm / 5,0mm
3,5mm / 4,0mm / 4,5mm / 5,0mm
Height. 1
Height. 1
Height. 2
Height. 2
Height. 3
Height. 3
Height. 4
Height. 4
Height. 5 Alt. 6
Height. 5 Height. 6
Ø Pillar
Ø Pillar
4,5
4,5
5,0
5,0
5,5
5,5
h h
h
h
h h h
h h
h
h
2,60mm
h
2,60mm
OVERCAST PROSTHESISSEMI CALCINABLEMechanized cylinder provides a perfect adjust with the implant, keeping pilar-implant zones unalterable during all prosthesis manufacturing process.
With hexagon - Suitable for unitary restorations, it avoids pillar rotations over implant. Used for indi-vidual pieces construction in threaded prosthesis or in stump manufacturing in cemented prosthe-sis.
Circulars - Suitable for multiples restorations as threaded bridges, bars or hybrid prosthesis. Being multiples prosthesis it is not necessary to keep the hexag
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 29
Overcast pillar diameters are 4,5, 5,0 y 5,5 mm. Specified in reference.
i
Ask for overcast protocols in our guide.
Hexagonal
Circular
GNPS4501HGNPS5001HGNPS5501H
GNPS4502HGNPS5002HGNPS5502H
GNPS4503HGNPS5003HGNPS5503H
GNPS4504HGNPS5004HGNPS5504H
GNPS4505HGNPS5005HGNPS5505H
GNPS4506HGNPS5006HGNPS5506H
GNPS4501RGNPS5001R GNPS5501R
GNPS4502RGNPS5002R GNPS5502R
GNPS4503RGNPS5003R GNPS5503R
GNPS4504RGNPS5004R GNPS5504R
GNPS4505RGNPS5005R GNPS5505R
GNPS4506RGNPS5006R GNPS5506R
Ø Platform
Ø Platform
3,5mm / 4,0mm / 4,5mm / 5,0mm
3,5mm / 4,0mm / 4,5mm / 5,0mm
Height. 1
Height. 1
Height. 2
Height. 2
Height. 3
Height. 3
Height. 4
Height. 4
Height. 5 Height. 6
Height. 5 Height. 6
Ø Pillar
Ø Pillar
4,5
4,5
5,0
5,0
5,5
5,5
They are screwed to the implant with the hexagonal screw GNTRHC through the DL120 screwdriver
h h
h
h
h
h
hh
h
h
h
2,60mm
h
2,60mm
i
Pilar over implant to made overcasts for making up structures threaded over the implant.With hexagon - For unitary restorations, avoiding any rotation over the im-plant.Circular - For threaded multiple restorations, bars or hybrid prosthesis.Material Cromo Cobalto.They are provided with a pillar inner cone adjustment unlock with im-plant.They are threaded to implant with hexagonal screw GNTRHC by means of DL120 screwdriver.
OVERCAST PILLARS
OVERCAST PROSTHESISOVERCAST PILLAR
30
OVERDENTURES PROSTHESISOSSCILIAOSSCILIA RETENTION SYSTEM
20º 20º
Our new system allows an adaptation to implant disparallelism of 20º.
0,2 mm
Microdent Osscilia set is a overdenture retention system destined to edentulous patient restorations. This system advantages respect to other systems and justified by its design are:
- Easy teflon exchange by the clinician without laboratory intervention.
- Reduced prosthetic high
- Wide range of progressive highs pillars
- 3,50mm pillar emergence diameter
Retentive set comprises metal cap and three interchangeable retainers housed inside the metal cap and threaded with a simple key. It is screwed to the implant with the screwdriver DL120.
Three retention levels, identified by plastic cap colourPlastic black capSupplied with embedded metal sheath, it has a soft retention for clinical or laboratory tests. Plastic white capIt has a medium retention very appropriate to keep stable during a long time period.Plastic red capUsed in specific cases where extreme fixation is required.
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 31
OVERDENTURES PROSTHESISOSSCILIA
Composed by: Osscilia pillar Metalic cap Soft retainer
OSSCILIA SYSTEM
Medium retainer Strong retainer
CSUTOSS
SUTCM SUTTFS SUTTFM SUTTFF
TransferRef. SUTGTOSS Ref. MSGNOSSRI35
Analogue
Osscilia impression taking
2,72 mm
h 0mm
4,50 mm
CGNOSS3500 CGNOSS3501 CGNOSS3502 CGNOSS3503 CGNOSS3504 CGNOSS3505 CGNOSS3506
Ø Platform
Ø Pillar 3,5
3,5mm / 4,0mm / 4,5mm / 5,0mm Height. 0 Height. 1 Height. 2 Height. 3 Height. 4 Height. 5 Height. 6
Osscilia pillar diameter is 3,5mm. Specified in reference.
i
MC220PB
Key for Osscilia retainers
h hh hh h
OSSCILIA SET
32
IMPLANTOLOGY ENGINESVARIOSURG IMPLANTOLOGY PIEZO ELECTRIC
SURGIC PRO NSK IMPLANTOLOGIC ENGINE
Designed specifically to oral surgery and implants, Surgic Pro pro-vides all necessary potency and performance for surgical process. Its 210w potency and its potent 50 Ncm torque, joint its wide speed spectrum between 200 and 40.000 min-¹, offers necessary flexibil-ity and fast answer for different surgical process. Prefixed memory, programmed by the user, allows store until 10 preferred specifica-tions (speed, torque, refrigerant flux and rotation direction). Moreo-ver, operation with free hands because of feed control unit helps you to be concentrate on your patients.
The latest model in the VarioSurg range keeps the light-weight and the thin design of the handpiece from his predecessor. It keeps as well the same grip and balance but adding 50% of pow-er over the former model.The feedback and automatic adjustment functions combined with a wide range of tips ensure faster and more precise treat-ments. Variosurg3 also has the first dinamic link function in the world which allows to use both, Variosurg3 and Surgic Pro though an unique pedalIntuitive controls and a big LCD screen with a clear backlight make the engine very easy to use.Applications: bone surgery, sinus lifting, extraction, implant preparation.Main characteristics: Bigger impulse, 3 modes (surgery, en-dodontics and periodontics), selectable burst mode, 9 pro-grammes, adjustable LED light intensity, self-cleaning, feed-back function, automatic set-up function, dynamic Lin function.
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 33
SCREWDRIVERS
PROSTHESIS SCREWDRIVERS
Short Long Extra short
MH120C MH120L MH120EL
Short Long
SUH120RC SUH120RL
DL120HC
Short Long
DL120HL DC120HC
Short Long
DC120HL
ROTATING MANUAL KEYS OF SURGERY
Used in surgery display the same features than fixed keys but adding a greater comfort in its use, simplifying retentive tighten action.
These manual spanners are used to tighten the retention screws and the other addiments of the prosthesis. They are made of strong very hard wearing stainless steel.
CONNECTOR FOR TORQUE AND RATCHET SPANNER
Designed for our torque and ratchet spanners, this connector must be used very carefully because of the free tightening strength capacity.
SCREWDRIVER FOR CONTRA-ANGLE PARTS
These spanners used with the contra-angle parts are highly recommended because of the easy control of the torque.
34
NON TRAUMATIC EXPANDERS
The non traumatic Microdent expanders developed by Microdent stand for an important technological innovation for oral implantology as a product of global reference and an essential instrument for any professional in implan-tology. This practical and simple bone expansion system avoids surgical trauma and allows an expansion effective measured and progressive con-trol.Microdent expanders have been re-designed replacing colour code plastic ring for other metallic and practical ring which assures more durability. On design level, they have included some modification updating its image.Microdent has on implantology professional disposition two expansion kits: one expanders box containing five expanders and one additional lift, and new complete bone expansion kit, with a new design, with all necessary ad-ditional material and instrument.
Many clinical features
They just need a fissure drill or circular drill to start process.
Intermediate hazel drill in type bone D-2 have been deleted from the protocol.
In bone type D-3 we use bone bloody addition excess. Using just one opening drill, we coolosteotomy.
They take advantage in whole procedure the excess bone keeping compacted in newalveolus, because of expander thread design.
In bone type D-4 presenting a low percentage of bone tissue of all bone types, tri corticalanchor succeed. Being able to use larger diameter implants and to start from cortical crestfrom 1 to 2mm., we can insert 5mm implants.
Our expander n.6, special design, allows non traumatic sinus left, avoiding bone tablefracture.
CONSIDERATIONS ABOUT DIFFERENT BONE TYPES
TYPE A BONEBone with:
Width > 5mm.Height: 10 – 12 mm.Lenght > 5mm.Angle > 30%
TYPE B BONEBone with:
Width > 2,5 - 5mm.Height: 10 – 12 mm.Lenght > 15mm.Angle > 20%
TYPE C BONEBone with:
- Unfavourable height and width bone and unfavourable length and angle bone.
TYPE D BONEFeatured by:
- Intense atrophy- Basal bone loss- Plane upper jawbone- Mandible on pencil
BONE EXPANSIONTECHNIQUE DEVELOPMENT
Expansion kit ref. KITEXPkit contents:
·Expanders num. 1, 2, 3, 4 and 5·Bone dilators num. 2, 3, 4 and 5 in duplicate·Sinus compactor·Short extensor·Expanders manual key·Bolt·Expander pilot drill·Crest longitudinal opening drill·Circular saw
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 35
nº 1 1025 nº 2 1830 nº 3 2938 nº 4 3345 nº 5 4452 nº 6 3535
Many advantages with outstanding features
· Non traumatic use.
· Expand thin crests, increasing the thickness without loosing the bone.
· Compact bone around the implant for better osseointegration.
· Perfect control of the insertion axis.
· Economic, since in some cases it replaces drill erosion.
· The gradual thread introduction causes bleeding, favouring osseointegration.
· Excellent expander manual or mechanical control minimizes labial drill ing risks in the upper compact jawbone labial side.
· Universal application for all system implants.
Basic expansion kit ref. 555Kit contents:Expander nº 1, 2, 3, 4 y 5Sinus compactor 3535
Particular recommended for:Narrow crest regardless the bone type.II, III and IV bone type.I bone type combined with traditional drill system.Non traumatic sinus lifts through implant site. For more information ask for our 3D animation and our Expander Use
Manual.
* SInus compactor for 4,20mm implants.8, 10, 12 and 14 depth marks.
BONE EXPANSIONBASIC INSTRUMENTATION
(*)
Spain patent: 9602250EE.UU patent: 6146138Europe patent: 023801558
Ø 3,50 mm
8101214
36
This is a series of instruments deigned by Microdent and incorporated into its well-knownbone expansion technique called Esbipro. Microdent dilators act in combination amongthemselves during expansion process. Dilators main function is to maintain controlled thebone table expansion sequentially, just before to proceed to implant insertion in the mouth,acting naturally as a final retainer and avoiding other intermediate solutions.With dilators use you can provide a new and important complete bone expansion process.The new technique allows a sequence where to practise a more precise control over the expansion.New bone expansion kit is available with a pair of each measure of dilators, identified bycomplementary expander colour.Microdent makes continuously courses and workshops showing and practicing work processwith new Dilators.
CDH02 CDH03 CDH04 CDH05
INSTRUMENTAL FOR BONE EXPANSION
Drill
To perforate the crest andallow the introduction ofthe expander ref. 1025
Circular drill
This is used to open thecrest lengthwise.
701 drill
Drill to used for crest lon-gitudinal cut. Used at high speed with turbine.
Manual spanner
This provides a very sensi-tive control of the expan-sion.
Tightening
Handle of the manual spanner.
F1312 F101 701 644 35
BONE EXPANSIONDILATORS
1,20 mm1 mm
0,10 mm
8 mm
3,0mm
1,5mm 1,9mm 2,3mm 3,0mm
3,8mm 4,5mm 5,0mm
12,5mm 12,5mm 12,5mm 12,5mm
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 37
CF42C CF50C
Ø 3,80Ø 4,60
L 5,0 L 5,0
Previous drilling for this model can´t be higher than 3,20mm. diameter.
Previous drilling for this model can´t be higher than 2,80mm. diameter.
Made on surgical stainless steel
Cortical Fix double adjustable action sinus lift makes reference to a new instrument for oral surgery developed and patented by Microdent and destined to increase sinus subantral zone second cortical by slow and controlled compression .Helped by this dispositive they achieve larger implant insertion and, consequently, stability, security and osteointegration condition improve in this zone where bone quality is often precarious. Dispositive original design has a very simple functionality and scarce traumatic incidence because of Cortical Fix self threading in bone insertion, which follows the same protocol as it was an normal im-plant. Moreover, once piston is activated in alveolus where dispositive is fixed, the Cortical Fix body is removed, placing a larger definitive implant, with suitable measures for an excellent primary retention. With Cortical Fix incorporation to Implantologic Surgery, Microdent has pretended:- To enrich upper maxilla bone by compression, therefore we have developed a bone intermediate com-pacter acting previously to dispositive fixation. -To keep threaded body without movement during piston activation, being this condition indispensable to second cortical progressive lift, avoiding sinus perforation because of its slow detachment. Bone lift gain achieved is approximately 4mm. (piston movement)
PRESENTATION
You can fix 4,20mm. diameter implants and lengths between 6 and 10mm.
You can fix 5,00mm. diameter implants and lengths between 6 and 10mm.
CORTICAL FIXMICRODENT SINUS LIFT
4mm 4mm
38
SURGICAL INSTRUMENTAL REQUIRED FOR FIXING CORTICAL FIX IN THE BONE
Long
CF06L CF06C ACL44 CF07
FC20CCF42R CF50R
CFFT280 CFFT320
Short Extensor Dismantling key
· Bone intermediate compactor ref. CF42R and CF50R· Drill for plucking and cortical drilling ref. FC20C · Initial 2,80mm diameter drill with depth limit (for 4,20mm im-plants) ref. CFFT280 (with limit)· Final 3,20mm drill with depth limit (for 5,00mm implants) ref. CFFT320 (with limit)
5 mm
5 mm
6 mm10 mm
·Bone intermediate compactor for Cortical Fix (4,20).
· Bone intermediate compactor for Cortical Fix (5,00).
Important:Inserting Cortical Fix, adjustable piston must be totally deactivated (anticlockwise).
Cortical-Fix Kit with all the necessary instru-ments for its implemented.
3,5mm 4,2 mm
*1,90 mm
8mm5mm 5mm
8mm
·Keys for control and advance piston: ref. CF06L long ref. CF06C short·Extensor ref. ACL44·Dismantling key ref. CF07
Ref: KITCF
Ø 5,8mm
17mm
Kit contents are subject to change.i
4 mm 4 mm
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 39
SPECIAL IMPLANTSPROVISIONAL IMPLANTS PIMplusIMPLANTS FOR ELABORATING PROVISIONAL PROSTHESIS Microdent has added to his implant line oriented to retain the overdentures with independent ball abutements, a new implant design with the peculiarity that the ball pillar forms a one piece with the implant to which the Osscilia retainers are adapted. With diameters for endo-osseo fixing of 2,0 mm and 2,5 mm, the PIMplus implants are indicated to fix in free areas or between definitive implants. They are transmucosal placed with a minimum surgical trauma for patients and it can tolerate easily a provisional prosthesis retained by the spherical shape of the implant.
DRILLS FOR IMPLANT PLACEMENT 2,0mm.The protocol for this implant only requires use Ø 1,50mm drill
DRILLS FOR IMPLANT PLACEMENT 2,5mm.The protocol for this implant only requires use Ø 1,80mm drill
Long Long
Reference Reference Reference
Short Short
F1517 1817F1512 1812
L L L
Ø 2,0 Ø 2,50Ø 2,80
LL
12 PIM2012 12 PIM2512 12 MST2812
10 PIM2010 10 PIM2510 10 MST2810
8 PIM2008 8 PIM2508 8 MST2808
14 PIM2014 14 PIM2514 14 MST2814
16 PIM2016 16 PIM2516 16 MST2816
ONE PIECE ONE PIECE IMPLANT+OSSCILIA PILLAR
40
CONTRA-ANGLE SPANNER ADAPTERS IMPRESSION TAKING
Short AnalogueLarge Transfer
PIMAFC PIMRIPIMAFL PIMTCC
LPC
INSTRUMENTAL
Se emplea para la fijación de implantes con el motor. El interior se ajusta al hexágono del implante.
Para utilizar en espacios interdentarios o en zonas de dificil acceso.
PROTHESIS - OVERDENTURES
Genius Implant Trylogic implant System Universal
Metalic cap Soft retainer
OSSCILIA SYSTEM
Medium retainer Strong retainer Osscilia retainer key
SUTGCM SUTGTFS SUTGTFM SUTGTFF
4,50 mm
MC220PB
On every single implant from internal or external connection of Microdent systems, it is possible to assemble an exchangeable ball pillar with differents gingival heights, in which rehabilitation is definitively complemented by means of the Osscilia retainers.
ww
w.m
icro
dent
syst
em.c
om
GENIUS - With Internal Prosthetic Connection 41
Customer attentionAttention phone to customer is 902 402 420 in schedule from Monday to Thursday from 9h to 18h. On Friday it will be from 8h to 15h continuously.
Order placingOrders can be placed by phone at 902 402 420 in 1 extension phone (orders)- By fax at 00 34 93 844 76 93- By e-mail at [email protected] By means of our website; www.microdentsystem.com- By your zone commercial officer
Delivery terms- Peninsula for orders placed before 14h, material will be delivered before 19:00hrs. of the next day.- Canary Islands 24-48h for orders placed before 14h- In the same day, please consult (only for Barcelone province)
Products expeditionAlways for orders placed before 14h.In placing your order, let us know chosen schedule:- Service 8.30h- Preferred; material will be delivered between 8.30 -10h- Express; material will be delivered between 10h a 13h.- Service 19h; material will be delivered in the afternoon before 19h.- Emergency, orders placed out of schedule (in the afternoon) have a surcharge of 10eur.*Available for entire peninsula. Canary consult
ReturnsReturns won’t be admitted after 30 days from material receptionAll material returns must be companied by product return file duly completed and including a delivery note copy.
Invoicing and payment formDebit at 30 days from invoice date.Consult other payment modalities and facilities to our customer attention department or to your zone commercial officer.
* Microdent reserves the right to make any modification without previous notice.
GENERAL CONDITIONS
Desi
gn:
2014