This Technical Manual contains Capral priviledged information and is subject to Copyright
Index - Page 1
400 Narrowline
Index
01-08-2013
TECHNICAL MANUAL HISTORY History.. Manual History 1
FEATURES & BENEFITS Section 1.. Features & Benefits 1
PRODUCT SPECIFICATIONS Section 2.. Product Specifications 1
PRODUCT SPECIFICATIONS Section 2a.. Structural & Water Test Report Summary 9962S3A F.F / F 1 Structural & Water Test Report Summary 9962S3B F.F / F 2 Structural & Water Test Report Summary C011-010 F.F 3 Structural & Water Test Report Summary C011-010A F.F 4 Structural & Water Test Report Summary C011-012 F.F 5 Structural & Water Test Report Summary C011-013 F.F 6 Structural & Water Test Report Summary C011-019 F.F 7 Structural & Water Test Report Summary C011-020 F.F 8 Structural & Water Test Report Summary C011-021 F.F 9 Structural & Water Test Report Summary C011-022 F.F 10 Structural & Water Test Report Summary C011-030 F/F 11 Structural & Water Test Report Summary C011-031 F/F 12 Structural & Water Test Report Summary C011-032 F/F 13 Structural & Water Test Report Summary C011-046 F/F 14 Structural & Water Test Report Summary C011-047 F/F 15 Structural & Water Test Report Summary C011-048 F/F 16 Structural & Water Test Report Summary C011-049 F/F 17 Structural & Water Test Report Summary C011-052 F.F 18 Structural & Water Test Report Summary C011-054 F.F 19 Structural & Water Test Report Summary C011-055 F.F 20 Structural & Water Test Report Summary C011-056 F.F 21 Structural & Water Test Report Summary C013-004 F.F 22 Structural & Water Test Report Summary C013-007 F.F 23 Structural & Water Test Report Summary C013-008 F.F 24 Structural & Water Test Report Summary C013-013 F.F 25 Structural & Water Test Report Summary C013-024 F.F 26 Structural & Water Test Report Summary C013-029 F.F 27 Structural & Water Test Report Summary C013-032 F.F 28 Structural & Water Test Report Summary C013-033 F.F 29 Structural & Water Test Report Summary C013-034 F.F 30
PRODUCT SPECIFICATIONS Section 2bb. Acoustic Test Report Summary ATF 1152 & ATF 1153 F.F / F 1 Acoustic Test Report Summary 4870-25 & 4870-16 F.F 2
Index - Page 2
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Index
01-08-2013
PRODUCT SPECIFICATIONS Section 2c.. Span Table - Light Mullion EN9457 / EN9499 1 Span Table - Medium Mullion EN5010 / EN9499 2 Span Table - Heavy Mullion EN5011 / EN9499 3 Span Table Light Split Mullion EP5408 / EP5408 4 Span Table - Medium Split Mullion EP5408 / EP5409 5 Span Table - Heavy Split Mullion EP5409 / EP5409 6 Span Table - Corner Mullion EN9499 / EN5014 / EN9499 7 Span Table Tubular Transom EN5021 8 Span Table 2 Piece Transom EN5020 / EN9499 9 Maximum Glass Thickness Table Tubular Transom EN5021 10 Maximum Glass Thickness Table 2 Piece Transom EN5020 / EN9499 11
EXTRUSIONS Section 3.. Extrusions 1 - 6 Extrusion Data 7
COMPONENTS Section 4.. Components 1
CONFIGURATIONS Section 5.. Configurations 1
ARRANGEMENT DETAILS Section 6.. Vertical Arrangement 01, 02 & 03 Head, Transoms & Sill 1 Vertical Arrangement 02 & 03 - Internal Glazing 2 Horizontal Arrangement 04 & 05 Jamb & Mullions 3 Horizontal Arrangement 04, 06 & 08 Alt. Jamb & Self Mating Mullions 4 Horizontal Arrangement 07 2/3 Way Post Mullion & Corner 5 Arrangement Interior Glazed Partition 6
GLAZING DETAILS Section 7.. Glazing Details 1
CUTTING FORMULAS & BOMs Section 8.. Refer to arrangements (Section 6) for dimensions
ASSEMBLY DETAILS Section 9.. Assembly Head 1 Assembly Sill & Internally Glazed Sill 2 Assembly Mullion & Transom 3 Assembly Build In Brackets 4 Assembly Glazing 5
MACHINING DETAILS Section 10.. Machining Jambs 1 Machining Jambs (Internal Glazing) 2 Machining Sill Drainage 3 Machining Tubular Transom Drainage 4 Machining Bead Drainage 5
This Technical Manual contains Capral priviledged information and is subject to Copyright
Index - Page 3
400 Narrowline
Index
01-08-2013
DISCLAIMER ..
Whilst every effort has been made to ensure the technical details contained herein are accurate and correct, Capral can take no responsibility for any loss or damage whatsoever arising as a result of any errors contained in this manual. Also, interpretation of standards or codes within this manual is Caprals interpretation of such codes. Responsibility for code compliance remains with the user of this manual. In some cases product dimensions may vary or be changed without notice. Capral assumes no duty of care in respect of any drawings or information contained in this manual. Readers should not act or rely upon any information contained in this manual without obtaining appropriate professional advice relating to their particular circumstances. Capral disclaims all liability for loss of damage suffered by any party who acts or fails to actin reliance of this manual.
COPYRIGHT ..
This technical manual remains the property of Capral and contains privileged information which is the subject of copyright and the manual or any part thereof may not be reproduced, copied or loaned in any form without the written permission of Capral. Issue of this manual is conditional on signed acknowledgment of these conditions. This manual is to be returned to Capral when requested.
CAPRAL GENERAL WARRANTY ..
No warranty, condition or term applies to the supply by Capral of products and their components manufactured by it unless it is set out in this Condition or is implied by law and cannot be excluded.
If any term is implied into this Condition by law, and it would be illegal for Capral to exclude it, then so far as the law allows,the liability of Capral for breach of that term is limited to the cost of repair or replacement (at Capral's option) of any product or component manufactured by it that Capral determines is defective in materials under normal use and service. Capral is not liable for any other direct or indirect cost, loss or damage to person or property, or for any consequential losses, including cartage and installation.
While any product or component is in the custody of Capral for investigation or repair it will be at the risk of the purchaser and Capral or its employees or agents will not be liable for any damage to it.
Capral is not liable to the purchaser unless the purchaser notifies Capral in writing immediately on it becoming aware of the alleged defect, and in any event no later than 30 days after the date of delivery.
Capral is not liable for any product or component that is not manufactured by it, but Capral will use its reasonable endeavors to obtain for the purchaser the benefit of any applicable manufacturers warranty.
This Technical Manual contains Capral priviledged information and is subject to Copyright
Manual History - Page 1
400 Narrowline
Technical Manual History
01-08-2013
The table below is a record of this manuals history. Any changes or additions to this manual are listed below.
DATE DESCRIPTION DESTROY PAGES INSERT PAGES 01-08-2013 New Manual Released - -
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 1 - Page 1
400 Narrowline
Features & Benefits
01-08-2013
__________________________________________________________________________________________
101.6mm x 44mm Frame
Single Glazed Options (up to 10mm)
Externally or internally center glazed frame
Exclusively designed components to improve the systems performance and function
NATA tested to Australian Standards (AS2047-1999)
Max Tested Serviceability Limit State (SLS) Pressures up to 5,200 Pa*
Max Tested Ultimate Limit State (ULS) Pressures up to 10,300 Pa*
Max Tested Water Performance up to 1,500Pa*
Window Energy Rating Scheme (WERS) data available; www.wers.net
Acoustic Sound Insulation Rating (Rw (C;Ctr)) up to 37 (-1;-3)*
Compatible with 425 Double Glazed Narrowline 200 & 275 Series Doors 900 Sliding Door Artisan Folding Doors Genesis 400 Series 35 & 50 Series Windows 471 Double Hung Window 480 Sliding Window 950 Sliding Widow Euro Tilt & Turn Window Euro Awning / Casement Window 400 Louvre Adaptor
* Refer to Section 2 for specific details and limitations
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2 - Page 1
400 Narrowline
Product Specifications
01-08-2013
SIZE LIMITATIONS
Mullion Height Mullion Spacing Minimum: 600mm Minimum: 300mm Maximum: 4000mm Maximum: 2400mm
Transom Width Transom Spacing Minimum: 300mm Minimum: 300mm Maximum: 3000mm Maximum: 1500mm
NOTE: Refer to the information below & Span Tables to check the maximum sizes that can be achieved for the assigned performance requirements of the installation.
SERVICEABILITY PRESSURE & WATER PERFORMANCE Residential (L/180) & Commercial (L/250) Applications: The Serviceability Pressures listed in the Span Tables have not been limited by a water performance.Where water performance is necessary the product should be limited to the following maximum water ratings or serviceability pressures:
Configuration Sill Transom Max. Water Rating (Pa) Max. Serviceability
Pressure (Pa) (Max. Water Rating / 30%)
F.F / F (Roll in Wedges) EN5020 / EN5032 EN9499 / EN5020 / EN5032 1000 3333
F.F / F (Silicone Glazed) EN5020 / EN5032 EN9499 / EN5020 / EN5032 1000 3333
F.F(Roll in Wedges)
EN5032 / EN5020 N/A 920 3067 EN5032 / EN5020
(Internal Bead) N/A 900 3000 F.F
(Silicone Glazed) EN5032 / EN5020 N/A 1510 5033
F/F(Roll in Wedges)
EN5020 / EN5032 (Internal Bead)
EN5021 / EN5032 (Internal Bead) 913 3043
EN5020 / EN5032 EN5020 / EN9499 / EN5032 300 1000 F/F
(Silicone Glazed)
EN5020 / EN5032 (Internal Bead)
EN5021 / EN5032 (Internal Bead) 1521 5070
EN5020 / EN5032 EN5020 / EN9499 / EN5032 1513 5043
Note: The use of a standard Subsill has been assumed for the Water Performance Ratings listed above.
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2a - Page 1
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: 9962S3A Performed by: Ian Bennie & Associates Test Laboratory, Victoria December, 1999 Test Drawing Number: 400-001
Configuration: F.F / F Glass: 6mm Clear Float
Bead / Glazing: External Bead / Roll in Wedges
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
AIR INFILTRATION RESULTS: 0.04L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.04L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill: EN6523 / EN5020 / EN5032 1000Pa Pressure for a period of 15mins Transom: EN9499 / EN5020 / EN5032
Section 2a - Page 2
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: 9962S3B Performed by: Ian Bennie & Associates Test Laboratory, Victoria December, 1999 Test Drawing Number: 400-002
Configuration: F.F / F Glass: 6mm Clear Float
Bead / Glazing: External Bead / Silicone Seal
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
WATER PENETRATION RESULTS: Sill: EN6523 / EN5020 / EN5032 1000Pa Pressure for a period of 15mins Transom: EN9499 / EN5020 / EN5032
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2a - Page 3
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-010 Performed by: Capral Mechanical Test Laboratory, Victoria April, 2011 Test Drawing Number: 31-440
Configuration: F.F
Glass: 10.38mm Laminate Bead / Glazing: External Bead / Silicone Seal
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion Configuration: EN9457 / EN9499 2704Pa 2710Pa (1735mm Span) (Span/261) (Span/271)
AIR INFILTRATION RESULTS: 0.03L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.08L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill: EN5032 / EN5020 / EN6523 1511Pa Pressure for a period of 15mins
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
5000Pa 5026Pa
Section 2a - Page 4
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-010A Performed by: Capral Mechanical Test Laboratory, Victoria April, 2011 Test Drawing Number: 31-441
Configuration: F.F
Glass: 10.38mm Laminate Bead / Glazing: External Bead / Roll in Wedges
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion Configuration: EN9457 / EN9499 2508Pa 2530Pa (1735mm Span) (Span/256) (Span/278)
AIR INFILTRATION RESULTS: 0.04L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.00L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill: EN5032 / EN5020 / EN6523 755Pa Pressure for a period of 15mins
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
3554Pa 3512Pa
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2a - Page 5
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-012 Performed by: Capral Mechanical Test Laboratory, Victoria April, 2011 Test Drawing Number: 31-442
Configuration: F.F
Glass: 10.38mm Laminate Bead / Glazing: External Bead / Roll in Wedges
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion Configuration: EN5010 / EN9499 2812Pa 2814Pa (1764mm Span) (Span/251) (Span/265)
AIR INFILTRATION RESULTS: 0.30L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.10L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill: EN5032 / EN5020 / EN6523 921Pa Pressure for a period of 15mins
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
5029Pa 4211Pa
Section 2a - Page 6
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-013 Performed by: Capral Mechanical Test Laboratory, Victoria April, 2011 Test Drawing Number: 31-445
Configuration: F.F
Glass: 10.38mm Laminate Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion Configuration: EN5011 / EN9499 2907Pa 2918Pa (1764mm Span) (Span/271) (Span/257)
AIR INFILTRATION RESULTS: 0.21L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.06L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill: EN5032 / EN5020 901Pa Pressure for a period of 15mins
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
4488Pa 4495Pa
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2a - Page 7
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-019 Performed by: Capral Mechanical Test Laboratory, Victoria May, 2011 Test Drawing Number: 31-456
Configuration: F.F Glass: 8mm Toughened
Bead / Glazing: External Bead / Silicone Seal
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion: EN5014 / EN9499 / EN9499 / EK5925 4205Pa 4202Pa (2064mm Span) (Span/287) (Span/258)
AIR INFILTRATION RESULTS: 0.28L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.39L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill : EN5032 / EN5020 / EN6523 1512Pa Pressure for a period of 15mins
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
7241Pa 7518Pa
Section 2a - Page 8
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-020 Performed by: Capral Mechanical Test Laboratory, Victoria May, 2011 Test Drawing Number: 31-458
Configuration: F.F
Glass: 10.38mm Laminate Bead / Glazing: Internal Bead / Roll in Wedges
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion: EP5408 / EP5408 2902Pa 2922Pa (2064mm Span) (Span/256) (Span/268)
AIR INFILTRATION RESULTS: 0.01L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.00L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill: EN5032 / EN5020 / EN6523 899Pa Pressure for a period of 15mins (Internal Bead)
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
4572Pa 4564Pa
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2a - Page 9
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-021 Performed by: Capral Mechanical Test Laboratory, Victoria May, 2011 Test Drawing Number: 31-459
Configuration: F.F
Glass: 10.38mm Laminate Bead / Glazing: External Bead / Silicone Seal
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion: EP5408 / EP5409 3900Pa 3945Pa (2020mm Span) (Span/276) (Span/265)
AIR INFILTRATION RESULTS: 0.18L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.19L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill : EN5032 / EN5020 / EN6523 894Pa Pressure for a period of 15mins
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
8606Pa 8677Pa
Section 2a - Page 10
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-022 Performed by: Capral Mechanical Test Laboratory, Victoria May, 2011 Test Drawing Number: 31-460
Configuration: F.F
Glass: 8mm Toughened Bead / Glazing: External Bead / Silicone Seal
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion: EP5409 / EP5409 5255Pa 5249Pa (2060mm Span) (Span/250) (Span/284)
AIR INFILTRATION RESULTS: 0.47L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.43L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill: EN5032 / EN5020 / EN5693 1508Pa Pressure for a period of 15mins
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
10367Pa 10393Pa
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2a - Page 11
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-030 Performed by: Capral Mechanical Test Laboratory, Victoria August, 2011 Test Drawing Number: 31-469
Configuration: F/F
Glass: 8.38mm Laminated Bead / Glazing: Internal Bead / Captive Wedge (outside) / Roll in Wedge (inside)
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Transom: EN5032 / EN5021 2763Pa 2744Pa (1440mm Span) (Span/367) (Span/360)
AIR INFILTRATION RESULTS: 0.00L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.01L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill: EN5032 / EN5020 / EN5693 913Pa Pressure for a period of 15mins Transom: EN5032 / EN5021
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
2763Pa 3409Pa
Section 2a - Page 12
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-031 Performed by: Capral Mechanical Test Laboratory, Victoria August, 2011 Test Drawing Number: 31-470
Configuration: F/F
Glass: 8.38mm Laminated Bead / Glazing: Internal Bead / Silicone Seal
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
AIR INFILTRATION RESULTS: 0.00L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.00L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill: EN5032 / EN5020 / EN5693 1521Pa Pressure for a period of 15mins Transom: EN5032 / EN5021
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
4242Pa 4255Pa
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2a - Page 13
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-032 Performed by: Capral Mechanical Test Laboratory, Victoria August, 2011 Test Drawing Number: 31-471
Configuration: F/F
Glass: 8.38mm Laminated Bead / Glazing: External Bead / Silicone Seal
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Transom: EN5032 / EN5020 / EN9499 3035Pa 3057Pa (1430mm Span) (Span/366) (Span/386)
AIR INFILTRATION RESULTS: 0.04L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.05L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill: EN5032 / EN5020 / EN5693 1513Pa Pressure for a period of 15mins Transom: EN5032 / EN5020 / EN9499
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
4901Pa 3057Pa
Section 2a - Page 14
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-046 Performed by: Capral Mechanical Test Laboratory, Victoria November, 2011 Test Drawing Number: 31-504
Configuration: F/F
Glass: 6.38mm Laminated Bead / Glazing: External Bead / Roll In Wedges
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Transom: EN5021 / EN5032 600Pa 606Pa (2900mm Span) (Span/191) (Span/196)
AIR INFILTRATION RESULTS: 0.01L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.02L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill : EN5032 / EN5020 / EN5693 300Pa Pressure for a period of 15mins Transom : EN5021 / EN5032
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
855Pa 836Pa
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2a - Page 15
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-047 Performed by: Capral Mechanical Test Laboratory, Victoria November, 2011 Test Drawing Number: 31-505
Configuration: F/F
Glass: 6.38mm Laminated Bead / Glazing: External Bead / Silicone Seal
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Transom : EN5021 / EN5032 703Pa 712Pa (2900mm Span) (Span/163) (Span/172)
AIR INFILTRATION RESULTS: 0.01L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.02L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill : EN5032 / EN5020 / EN5693 449Pa Pressure for a period of 15mins Transom : EN5021 / EN5032
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
1217Pa 1217Pa
Section 2a - Page 16
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-048 Performed by: Capral Mechanical Test Laboratory, Victoria November, 2011 Test Drawing Number: 31-508
Configuration: F/F
Glass: 6.38mm Laminated Bead / Glazing: Internal Bead / Roll In Wedges
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Transom : EN5020 / EN9499 / EN5032 695Pa 697Pa (2930mm Span) (Span/211) (Span/210)
AIR INFILTRATION RESULTS: 0.02L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.03L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill : EN5032 / EN5020 / EN5693 302Pa Pressure for a period of 15mins Transom : EN5020 / EN9499 / EN5032
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
1038Pa 1032Pa
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2a - Page 17
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-049 Performed by: Capral Mechanical Test Laboratory, Victoria November, 2011 Test Drawing Number: 31-509
Configuration: F/F
Glass: 6.38mm Laminated Bead / Glazing: Internal Bead / Silicone Seal
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Transom : EN5020 / EN9499 / EN5032 715Pa 706Pa (2930mm Span) (Span/198) (Span/215)
AIR INFILTRATION RESULTS: 0.08L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.06L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill : EN5032 / EN5020 / EN5693 463Pa Pressure for a period of 15mins Transom : EN5020 / EN9499 / EN5032
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
1862Pa 1878Pa
Section 2a - Page 18
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-052 Performed by: Capral Mechanical Test Laboratory, Victoria December, 2011 Test Drawing Number: 31-512
Configuration: F.F Glass: 8.38mm Laminated
Bead / Glazing: External Bead / Roll In Wedges
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion : EP5408 / EP5408 501Pa 501Pa (2950mm Span) (Span/254) (Span/278)
AIR INFILTRATION RESULTS: 0.04L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.15L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill : EN5032 / EN5020 / EN5693 308Pa Pressure for a period of 15mins
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
1126Pa 1113Pa
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2a - Page 19
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-054 Performed by: Capral Mechanical Test Laboratory, Victoria December, 2011 Test Drawing Number: 31-514
Configuration: F.F Glass: 8.38mm Laminated
Bead / Glazing: External Bead / Roll In Wedges
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion : EN9457 / EN9499 611Pa 701Pa (2675mm Span) (Span/167) (Span/167)
AIR INFILTRATION RESULTS: 0.02L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.08L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill : EN5032 / EN5020 / EN5693 301Pa Pressure for a period of 15mins
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
1010Pa 1019Pa
Section 2a - Page 20
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-055 Performed by: Capral Mechanical Test Laboratory, Victoria December, 2011 Test Drawing Number: 31-515
Configuration: F.F Glass: 8.38mm Laminated
Bead / Glazing: External Bead / Roll In Wedges
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion : EN5010 / EN9499 606Pa 609Pa (2675mm Span) (Span/154) (Span/164)
AIR INFILTRATION RESULTS: 0.11L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.20L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill : EN5032 / EN5020 / EN5693 303Pa Pressure for a period of 15mins
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
1122Pa 1124Pa
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2a - Page 21
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C011-056 Performed by: Capral Mechanical Test Laboratory, Victoria December, 2011 Test Drawing Number: 31-516
Configuration: F.F Glass: 8.38mm Laminated
Bead / Glazing: External Bead / Roll In Wedges
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion : EN5011 / EN9499 618Pa 607Pa (2675mm Span) (Span/196) (Span/221)
AIR INFILTRATION RESULTS: 0.05L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.13L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill : EN5032 / EN5020 / EN5693 302Pa Pressure for a period of 15mins
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
1257Pa 1087Pa
Section 2a - Page 22
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C013-004 Performed by: Capral Mechanical Test Laboratory, Victoria February, 2013 Test Drawing Number: 31-618
Configuration: F.F
Glass: 8mm Toughened Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion : EN5409 / EN5409 4508Pa 4515Pa (2055mm Span) (Span/302) (Span/288)
AIR INFILTRATION RESULTS: 0.00L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.01L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill : EP12761 / EN5020 / EN5693 906Pa Pressure for a period of 15mins
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
9246Pa 9272Pa
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2a - Page 23
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C013-007 Performed by: Capral Mechanical Test Laboratory, Victoria February, 2013 Test Drawing Number: 31-623
Configuration: F.F
Glass: 8mm Toughened Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion : EN5409 / EN5408 4508Pa 4502Pa (2055mm Span) (Span/224) (Span/249)
AIR INFILTRATION RESULTS: 0.01L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.17L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill : EP12761 / EN5020 / EN5693 901Pa Pressure for a period of 15mins
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
7507Pa 7505Pa
Section 2a - Page 24
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C013-008 Performed by: Capral Mechanical Test Laboratory, Victoria March, 2013 Test Drawing Number: 31-624
Configuration: F.F
Glass: 8mm Toughened Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion : EN5408 / EN5408 3015Pa 3013Pa (2073mm Span) (Span/244) (Span/253)
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
5359Pa 5365Pa
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2a - Page 25
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C013-023 Performed by: Capral Mechanical Test Laboratory, Victoria May, 2013 Test Drawing Number: 31-641
Configuration: F.F
Glass: 10.38mm Laminated Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion : EN5011 / EN9499 4006Pa 4013Pa (1760mm Span) (Span/178) (Span/204)
AIR INFILTRATION RESULTS: 0.07L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.03L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill : EP12761 / EN5020 / EN5693 895Pa Pressure for a period of 15mins
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
5559Pa 5548Pa
Section 2a - Page 26
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C013-024 Performed by: Capral Mechanical Test Laboratory, Victoria May, 2013 Test Drawing Number: 31-644
Configuration: F.F
Glass: 10.38mm Laminated Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion : EN5010 / EN9499 3314Pa 3317Pa (1775mm Span) (Span/202) (Span/221)
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
4905Pa 4905Pa
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2a - Page 27
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C013-029 Performed by: Capral Mechanical Test Laboratory, Victoria June, 2013 Test Drawing Number: 31-647
Configuration: F.F Glass: 6.38mm Laminated
Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion : EP5408 / EP5408 553Pa 553Pa (2985mm Span) (Span/255) (Span/243)
AIR INFILTRATION RESULTS: 0.06L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.09L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill : EP12761 / EN5020 / EN5693 455Pa Pressure for a period of 15mins
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
1252Pa 1250Pa
Section 2a - Page 28
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C013-032 Performed by: Capral Mechanical Test Laboratory, Victoria June, 2013 Test Drawing Number: 31-652
Configuration: F.F Glass: 10.38mm Laminated
Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion : EN9499 / EN5014 / EN9499 705Pa 703Pa (3455mm Span) (Span/179) (Span/179)
AIR INFILTRATION RESULTS: 0.75L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.82L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill : EP12761 / EN5020 / EN5693 458Pa Pressure for a period of 15mins
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
1208Pa 1212Pa
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2a - Page 29
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C013-033 Performed by: Capral Mechanical Test Laboratory, Victoria July, 2013 Test Drawing Number: 31-651
Configuration: F.F Glass: 10.38mm Laminated
Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion : EP5409 / EP5409 697Pa 697Pa (3455mm Span) (Span/228) (Span/232)
AIR INFILTRATION RESULTS: 0.76L/s.m2 @ 75Pa Positive Test Pressure Achieved Air Conditioned Rating 0.71L/s.m2 @ 75Pa Negative Test Pressure
WATER PENETRATION RESULTS: Sill : EP12761 / EN5020 / EN5693 450Pa Pressure for a period of 15mins
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
1483Pa 1475Pa
Section 2a - Page 30
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Test Report Summary
01-08-2013
STRUCTURAL & WATER - TEST REPORT NUMBER: C013-034 Performed by: Capral Mechanical Test Laboratory, Victoria July, 2013 Test Drawing Number: 31-653
Configuration: F.F Glass: 10.38mm Laminated
Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Approved to Standard: AS4420-1996 (as called up by AS2047-1999)
DEFLECTION TEST RESULTS: + Test Pressure - Test Pressure
Mullion : EP5409 / EP5408 437Pa 437Pa (3455mm Span) (Span/287) (Span/294)
ULTIMATE STRENGTH RESULTS: + Test Pressure - Test Pressure
1164Pa 1162Pa
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2b - Page 1
400 Narrowline
Test Report Summary
01-08-2013
ACOUSTIC Performed by: Australian Hearing National Acoustic Laboratories, New South Wales October, 2001
Configuration: F.F / F
Approved to Standard: AS1191-2002
TEST REPORT NUMBER: ATF1152 Test Drawing Number: TA400-001
TEST SAMPLE DETAILS: Glass: 6.38mm Laminated Glass Glazing Wedge: M027142 (300013) 5mm Gap Glazing Wedge Backing Seal: M027403 (300841) Small Bulb Seal
SOUND TRANSMISSION CLASS: STC: 32
SOUND INSULATION RATING: Rw (C;Ctr): 32 (-1; -2)
TEST REPORT NUMBER: ATF1153 Test Drawing Number: TA400-002
TEST SAMPLE DETAILS: Glass: 10.38mm Laminated Glass Glazing Wedge: M027101 (300001) 3mm Gap Glazing Wedge Backing Seal: M027403 (300841) Small Bulb Seal
SOUND TRANSMISSION CLASS: STC: 34
SOUND INSULATION RATING: Rw (C;Ctr): 34 (-1; -2)
Section 2b - Page 2
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Test Report Summary
01-08-2013
ACOUSTIC Performed by: Australian Hearing National Acoustic Laboratories, New South Wales October, 2012
Configuration: F.F
Approved to Standard: AS1191-2002
TEST REPORT NUMBER: 4870-25 Test Drawing Number: 31-595
TEST SAMPLE DETAILS: Glass: 6.5mm Hush Laminated Glazing Wedge: 300013 5mm Gap Glazing Wedge; 315788 5mm Gap Captive Wedge Frame Seal: 316051 Mullion Seal
SOUND INSULATION RATING: Rw (C;Ctr): 34 (-0; -3)
TEST REPORT NUMBER: 4870-16 Test Drawing Number: 31-595
TEST SAMPLE DETAILS: Glass: 10.5mm Hush Laminated Glazing Wedge: 300001 3mm Gap Glazing Wedge; 315787 3mm Gap Captive Wedge Frame Seal: 316051 Mullion Seal
SOUND INSULATION RATING: Rw (C;Ctr): 37 (-0; -3)
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2c - Page 1
400 Narrowline
Span Table
Note:
S (L/250) 0.966 0.657 0.507 0.421 - - -S (L/180) 1.342 0.913 0.705 0.585 0.511 0.464 0.434S (L/150) 1.611 1.096 0.846 0.702 0.613 0.557 0.521
U 2.344 1.589 1.221 1.009 0.876 0.790 0.735S (L/250) 1.191 0.813 0.630 0.527 0.463 0.424 -S (L/180) 1.655 1.129 0.875 0.731 0.643 0.589 0.558S (L/150) 1.986 1.355 1.050 0.878 0.772 0.707 0.670
U 2.696 1.833 1.414 1.174 1.026 0.933 0.879S (L/250) 1.493 1.022 0.797 0.671 0.596 0.552 0.531S (L/180) 2.073 1.420 1.107 0.932 0.827 0.767 0.737S (L/150) 2.488 1.704 1.328 1.118 0.993 0.920 0.884
U 3.134 2.138 1.657 1.385 1.221 1.124 * 1.075 *S (L/250) 1.905 1.311 1.029 0.874 0.786 0.740 0.726S (L/180) 2.645 1.821 1.429 1.214 1.092 1.028 1.008 *S (L/150) 3.175 2.185 1.715 1.457 1.310 1.233 * 1.209 *
U 3.690 2.527 1.971 1.662 1.482 1.386 * 1.355 *S (L/250) 2.485 1.721 1.363 1.172 1.072 1.030 1.028 *S (L/180) 3.451 2.390 1.893 1.628 1.488 1.431 * 1.427 *S (L/150) 4.000 2.868 2.272 1.954 1.786 1.717 * 1.713 *
U 4.409 3.036 2.387 2.035 1.845 * 1.764 * 1.759 *S (L/250) 3.328 2.324 1.863 1.630 1.524 1.505 * 1.505 *S (L/180) 4.000 3.228 2.588 2.264 2.116 * 2.090 * 2.090 *S (L/150) 4.000 3.720 2.956 2.561 2.376 * 2.341 * 2.341 *
U 5.364 3.720 2.956 2.561 2.376 * 2.341 * 2.341 *S (L/250) 4.000 3.252 2.652 2.375 2.293 * 2.293 * 2.293 *S (L/180) 4.000 4.000 3.683 * 3.299 * 3.185 * 3.185 * 3.185 *S (L/150) 4.000 4.000 3.770 * 3.343 * 3.212 * 3.212 * 3.212 *
U 5.500 4.671 * 3.770 * 3.343 * 3.212 * 3.212 * 3.212 *600 900 1200 1500 1800 2100 2400
A maximum stress level of 110MPa has been applied when generating this table.
LEGEND: S = Serviceability Pressure, U = Ultimate Pressure
NOTE: This table is based on a combination of approved AS2047 testing data and theoretical section properties.
LIGHT MULLION 1 - EN9457 / EN9499
Mullion Height (mm)
Mullion Spacing (mm)
2400
1800
3000
Serviceability pressures for L/150 applications have been limited to a maximum Serviceability Pressure of 4000Pa.
2800
2000
2600
2200
Maximum Design Pressure (kPa)
Serviceability pressures for L/180 & L/250 applications have not been limited by water performance. Where water performance is necessary, refer to Product Specifications page.
* Indicates the "Braced Bead" (EP12761) should be used.
01-08-2013
Section 2c - Page 2
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Span Table
Note:
S (L/250) 0.804 0.545 0.419 - - - -S (L/180) 1.117 0.757 0.582 0.480 0.415 - -S (L/150) 1.340 0.909 0.698 0.576 0.499 0.448 0.414
U 2.150 1.454 1.112 0.914 0.787 0.702 0.645S (L/250) 1.021 0.694 0.535 0.444 - - -S (L/180) 1.418 0.964 0.743 0.617 0.538 0.487 0.455S (L/150) 1.702 1.157 0.892 0.740 0.645 0.584 0.546
U 2.522 1.709 1.312 1.083 0.939 0.845 0.784S (L/250) 1.324 0.903 0.700 0.585 0.515 0.471 0.446S (L/180) 1.838 1.254 0.972 0.812 0.715 0.655 0.620S (L/150) 2.206 1.505 1.167 0.975 0.858 0.786 0.744
U 3.000 2.040 1.573 1.307 1.142 1.039 0.978S (L/250) 1.759 1.206 0.942 0.794 0.707 0.658 0.635S (L/180) 2.443 1.675 1.308 1.103 0.982 0.914 0.882S (L/150) 2.932 2.010 1.569 1.324 1.179 1.096 1.059 *
U 3.629 2.477 1.923 1.610 1.424 1.315 * 1.263 *S (L/250) 2.409 1.663 1.311 1.120 1.015 0.965 0.956S (L/180) 3.346 2.310 1.821 1.556 1.409 1.340 * 1.327 *S (L/150) 4.000 2.772 2.185 1.867 1.691 1.608 * 1.593 *
U 4.479 3.076 2.407 2.040 1.834 * 1.732 * 1.713 *S (L/250) 3.427 2.388 1.908 1.661 1.543 1.514 * 1.514 *S (L/180) 4.000 3.316 2.650 2.307 2.143 * 2.103 * 2.103 *S (L/150) 4.000 3.926 3.111 2.683 2.472 * 2.419 * 2.419 *
U 5.500 3.926 3.111 2.683 2.472 * 2.419 * 2.419 *S (L/250) 4.000 3.613 2.946 2.638 2.547 * 2.547 * 2.547 *S (L/180) 4.000 4.000 4.000 * 3.664 * 3.538 * 3.538 * 3.538 *S (L/150) 4.000 4.000 4.000 * 3.720 * 3.574 * 3.574 * 3.574 *
U 5.500 5.198 * 4.195 * 3.720 * 3.574 * 3.574 * 3.574 *600 900 1200 1500 1800 2100 2400
A maximum stress level of 110MPa has been applied when generating this table.
Maximum Design Pressure (kPa)
* Indicates the "Braced Bead" (EP12761) should be used.
LEGEND: S = Serviceability Pressure, U = Ultimate Pressure
NOTE: This table is based on a combination of approved AS2047 testing data and theoretical section properties.
LIGHT MULLION 2 - EN5010 / EN9499
Mullion Height (mm)
Mullion Spacing (mm)
2550
1800
3300
Serviceability pressures for L/150 applications have been limited to a maximum Serviceability Pressure of 4000Pa.
3050
2050
2800
2300
Serviceability pressures for L/180 & L/250 applications have not been limited by water performance. Where water performance is necessary, refer to Product Specifications page.
01-08-2013
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2c - Page 3
400 Narrowline
Span Table
Note:
S (L/250) 0.756 0.511 - - - - -S (L/180) 1.050 0.710 0.544 0.447 - - -S (L/150) 1.260 0.852 0.653 0.537 0.463 0.413 -
U 2.142 1.446 1.104 0.904 0.775 0.689 -S (L/250) 0.946 0.642 0.493 - - - -S (L/180) 1.314 0.891 0.685 0.565 0.490 0.441 -S (L/150) 1.576 1.069 0.822 0.679 0.588 0.529 0.490
U 2.488 1.683 1.288 1.059 0.913 0.816 0.752S (L/250) 1.205 0.820 0.633 0.526 0.459 0.417 -S (L/180) 1.674 1.139 0.879 0.730 0.638 0.579 0.542S (L/150) 2.009 1.367 1.055 0.876 0.765 0.694 0.650
U 2.926 1.984 1.525 1.260 1.093 0.986 0.917S (L/250) 1.570 1.072 0.832 0.696 0.614 0.564 0.536S (L/180) 2.180 1.489 1.156 0.967 0.853 0.783 0.744S (L/150) 2.616 1.787 1.387 1.161 1.023 0.940 0.893
U 3.491 2.375 1.834 1.525 1.336 1.218 * 1.151 *S (L/250) 2.098 1.440 1.126 0.952 0.850 0.794 0.770S (L/180) 2.914 2.000 1.564 1.322 1.181 1.103 * 1.070 *S (L/150) 3.496 2.400 1.877 1.587 1.417 1.323 * 1.284 *
U 4.238 2.896 2.251 1.889 1.675 1.553 * 1.500 *S (L/250) 2.894 2.001 1.581 1.355 1.233 1.178 * 1.172 *S (L/180) 4.000 2.779 2.195 1.882 1.712 1.636 * 1.627 *S (L/150) 4.000 3.334 2.634 2.258 2.054 * 1.964 * 1.953 *
U 5.256 3.614 2.835 2.410 2.174 * 2.066 * 2.053 *S (L/250) 4.000 2.899 2.324 2.033 1.900 * 1.877 * 1.877 *S (L/180) 4.000 4.000 3.228 2.824 * 2.639 * 2.606 * 2.606 *S (L/150) 4.000 4.000 3.690 * 3.198 * 2.966 * 2.923 * 2.923 *
U 5.500 4.643 * 3.690 * 3.198 * 2.966 * 2.923 * 2.923 *600 900 1200 1500 1800 2100 2400
A maximum stress level of 110MPa has been applied when generating this table.
LIGHT MULLION 3 - EN5011 / EN9499
Mullion Height (mm)
Mullion Spacing (mm)
2750
2000
3500
Serviceability pressures for L/150 applications have been limited to a maximum Serviceability Pressure of 4000Pa.
3250
2250
3000
2500
Maximum Design Pressure (kPa)
Serviceability pressures for L/180 & L/250 applications have not been limited by water performance. Where water performance is necessary, refer to Product Specifications page.
* Indicates the "Braced Bead" (EP12761) should be used.
LEGEND: S = Serviceability Pressure, U = Ultimate Pressure
NOTE: This table is based on a combination of approved AS2047 testing data and theoretical section properties.
01-08-2013
Section 2c - Page 4
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Span Table
Note:
S (L/250) 0.981 0.664 0.508 0.418 - - -S (L/180) 1.362 0.922 0.706 0.580 0.500 0.447 0.410S (L/150) 1.635 1.106 0.847 0.696 0.600 0.536 0.492
U 2.715 1.833 1.399 1.146 0.983 0.873 0.797S (L/250) 1.227 0.832 0.640 0.528 0.458 0.412 -S (L/180) 1.705 1.156 0.888 0.734 0.636 0.572 0.530S (L/150) 2.045 1.387 1.066 0.881 0.763 0.686 0.635
U 3.154 2.133 1.633 1.343 1.158 1.035 0.953S (L/250) 1.564 1.064 0.821 0.682 0.596 0.541 0.506S (L/180) 2.172 1.478 1.141 0.947 0.827 0.751 0.703S (L/150) 2.607 1.773 1.369 1.137 0.993 0.901 0.843
U 3.709 2.515 1.933 1.597 1.386 1.250 * 1.163 *S (L/250) 2.037 1.391 1.080 0.904 0.797 0.732 0.695S (L/180) 2.829 1.932 1.500 1.255 1.107 1.016 0.966S (L/150) 3.395 2.319 1.800 1.506 1.328 1.219 * 1.159 *
U 4.425 3.011 2.325 1.934 1.693 1.544 * 1.459 *S (L/250) 2.722 1.869 1.461 1.235 1.104 1.030 0.999S (L/180) 3.781 2.596 2.030 1.716 1.533 1.431 * 1.388 *S (L/150) 4.000 3.115 2.436 2.059 1.839 * 1.717 * 1.666 *
U 5.373 3.672 2.854 2.395 2.123 * 1.969 * 1.902 *S (L/250) 3.754 2.596 2.051 1.758 1.599 1.529 * 1.520 *S (L/180) 4.000 3.605 2.849 2.442 2.221 * 2.123 * 2.111 *S (L/150) 4.000 4.000 3.418 * 2.930 * 2.666 * 2.548 * 2.534 *
U 5.500 4.581 * 3.593 * 3.055 * 2.757 * 2.619 * 2.602 *S (L/250) 4.000 3.762 3.016 2.638 2.466 * 2.435 * 2.435 *S (L/180) 4.000 4.000 4.000 * 3.664 * 3.425 * 3.382 * 3.382 *S (L/150) 4.000 4.000 4.000 * 4.000 * 3.760 * 3.705 * 3.705 *
U 5.500 5.500 * 4.678 * 4.053 * 3.760 * 3.705 * 3.705 *600 900 1200 1500 1800 2100 2400
A maximum stress level of 110MPa has been applied when generating this table.
MEDIUM MULLION 1 - EP5408 / EP5408
Mullion Height (mm)
Mullion Spacing (mm)
2750
2000
3500
Serviceability pressures for L/150 applications have been limited to a maximum Serviceability Pressure of 4000Pa.
3250
2250
3000
2500
Maximum Design Pressure (kPa)
Serviceability pressures for L/180 & L/250 applications have not been limited by water performance. Where water performance is necessary, refer to Product Specifications page.
* Indicates the "Braced Bead" (EP12761) should be used.
LEGEND: S = Serviceability Pressure, U = Ultimate Pressure
NOTE: This table is based on a combination of approved AS2047 testing data and theoretical section properties.
01-08-2013
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2c - Page 5
400 Narrowline
Span Table
Note:
S (L/250) 1.086 0.733 0.559 0.458 - - -S (L/180) 1.508 1.018 0.777 0.636 0.545 0.484 0.441S (L/150) 1.809 1.221 0.932 0.763 0.654 0.581 0.529
U 2.990 2.014 1.533 1.251 1.068 0.943 0.855S (L/250) 1.392 0.942 0.721 0.593 0.511 0.456 0.419S (L/180) 1.933 1.308 1.002 0.824 0.710 0.634 0.582S (L/150) 2.320 1.570 1.202 0.988 0.852 0.761 0.698
U 3.529 2.382 1.819 1.489 1.278 1.135 * 1.036 *S (L/250) 1.825 1.239 0.953 0.788 0.684 0.616 0.571S (L/180) 2.535 1.720 1.323 1.094 0.950 0.855 0.793S (L/150) 3.042 2.064 1.588 1.313 1.139 1.026 0.952
U 4.230 2.863 2.193 1.804 1.558 1.395 * 1.286 *S (L/250) 2.460 1.676 1.296 1.080 0.946 0.862 0.812S (L/180) 3.417 2.328 1.800 1.500 1.314 1.198 * 1.127 *S (L/150) 4.100 2.793 2.160 1.799 1.577 1.437 * 1.353 *
U 5.164 3.506 2.699 2.236 1.947 * 1.763 * 1.649 *S (L/250) 3.428 2.348 1.830 1.540 1.368 1.268 * 1.219 *S (L/180) 4.500 3.261 2.542 2.139 1.900 * 1.761 * 1.693 *S (L/150) 4.500 3.913 3.050 2.567 2.280 * 2.113 * 2.031 *
U 6.447 4.398 3.409 2.849 * 2.512 * 2.312 * 2.211 *S (L/250) 4.500 3.439 2.711 2.316 2.098 * 1.994 * 1.976 *S (L/180) 4.500 4.500 * 3.765 * 3.217 * 2.914 * 2.770 * 2.744 *S (L/150) 4.500 4.500 * 4.450 * 3.772 * 3.390 * 3.202 * 3.167 *
U 8.281 5.685 4.450 3.772 * 3.390 * 3.202 * 3.167 *S (L/250) 4.500 4.500 * 4.280 * 3.744 * 3.499 * 3.455 * 3.455 *S (L/180) 4.500 4.500 * 4.500 * 4.500 * 4.500 * 4.500 * 4.500 *S (L/150) 4.500 4.500 * 4.500 * 4.500 * 4.500 * 4.500 * 4.500 *
U 8.600 * 7.652 * 6.081 * 5.269 * 4.887 * 4.816 * 4.816 *600 900 1200 1500 1800 2100 2400
A maximum stress level of 110MPa has been applied when generating this table.
MEDIUM MULLION 2 - EP5408 / EP5409
Mullion Height (mm)
Mullion Spacing (mm)
2900
2000
3800
Serviceability pressures for L/150 applications have been limited to a maximum Serviceability Pressure of 4500Pa.
3500
2300
3200
2600
Maximum Design Pressure (kPa)
Serviceability pressures for L/180 & L/250 applications have not been limited by water performance. Where water performance is necessary, refer to Product Specifications page.
* Indicates the "Braced Bead" (EP12761) should be used.
LEGEND: S = Serviceability Pressure, U = Ultimate Pressure
NOTE: This table is based on a combination of approved AS2047 testing data and theoretical section properties.
01-08-2013
Section 2c - Page 6
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Span Table
Note:
S (L/250) 1.204 0.812 0.619 0.505 0.432 - -S (L/180) 1.673 1.128 0.860 0.702 0.600 0.531 0.481S (L/150) 2.007 1.353 1.031 0.842 0.720 0.637 0.577
U 3.492 2.350 1.787 1.455 1.239 1.090 0.985S (L/250) 1.524 1.030 0.787 0.645 0.554 0.492 0.449S (L/180) 2.117 1.430 1.093 0.896 0.769 0.684 0.624S (L/150) 2.540 1.716 1.311 1.075 0.923 0.820 0.749
U 4.086 2.755 2.099 1.714 1.466 1.297 * 1.178 *S (L/250) 1.968 1.333 1.022 0.842 0.727 0.651 0.599S (L/180) 2.733 1.851 1.419 1.169 1.010 0.904 0.832S (L/150) 3.280 2.221 1.703 1.403 1.212 1.085 0.999
U 4.847 3.274 2.502 2.052 1.764 1.570 * 1.438 *S (L/250) 2.603 1.769 1.362 1.129 0.983 0.888 0.828S (L/180) 3.615 2.456 1.892 1.568 1.365 1.234 * 1.149 *S (L/150) 4.338 2.948 2.271 1.881 1.638 1.480 * 1.379 *
U 5.843 * 3.958 3.037 2.504 2.167 * 1.946 * 1.803 *S (L/250) 3.545 2.419 1.875 1.567 1.378 1.262 * 1.195 *S (L/180) 4.923 3.359 2.604 2.176 1.914 * 1.753 * 1.660 *S (L/150) 5.908 4.031 3.125 2.611 2.297 * 2.104 * 1.992 *
U 7.183 * 4.884 * 3.767 * 3.129 * 2.734 * 2.487 * 2.342 *S (L/250) 5.003 3.435 2.686 2.271 2.028 * 1.893 * 1.837 *S (L/180) 5.200 4.771 * 3.731 * 3.154 * 2.817 * 2.630 * 2.551 *S (L/150) 5.200 5.200 * 4.477 * 3.785 * 3.381 * 3.156 * 3.062 *
U 9.046 * 6.182 * 4.805 * 4.033 * 3.575 * 3.315 * 3.202 *S (L/250) 5.200 5.119 * 4.055 * 3.488 * 3.188 * 3.065 * 3.057 *S (L/180) 5.200 5.200 * 5.200 * 4.844 * 4.427 * 4.257 * 4.246 *S (L/150) 5.200 5.200 * 5.200 * 5.200 * 4.916 * 4.701 * 4.687 *
U 10.300 * 8.089 * 6.359 * 5.423 * 4.916 * 4.701 * 4.687 *600 900 1200 1500 1800 2100 2400
A maximum stress level of 110MPa has been applied when generating this table.
HEAVY MULLION - EP5409 / EP5409
Mullion Height (mm)
Mullion Spacing (mm)
3100
2200
4000
Serviceability pressures for L/150 applications have been limited to a maximum Serviceability Pressure of 5200Pa.
3700
2500
3400
2800
Maximum Design Pressure (kPa)
Serviceability pressures for L/180 & L/250 applications have not been limited by water performance. Where water performance is necessary, refer to Product Specifications page.
* Indicates the "Braced Bead" (EP12761) should be used.
LEGEND: S = Serviceability Pressure, U = Ultimate Pressure
NOTE: This table is based on a combination of approved AS2047 testing data and theoretical section properties.
01-08-2013
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2c - Page 7
400 Narrowline
Span Table
Note:
S (L/250) 1.088 0.734 0.560 0.459 - - -S (L/180) 1.510 1.020 0.778 0.637 0.546 0.485 0.441S (L/150) 1.813 1.224 0.934 0.765 0.656 0.582 0.530
U 3.233 2.178 1.658 1.353 1.155 1.020 0.924S (L/250) 1.394 0.943 0.723 0.594 0.512 0.457 0.420S (L/180) 1.937 1.310 1.004 0.825 0.711 0.635 0.583S (L/150) 2.324 1.572 1.204 0.990 0.853 0.762 0.700
U 3.817 2.576 1.967 1.610 1.382 1.227 * 1.120 *S (L/250) 1.829 1.241 0.954 0.789 0.685 0.617 0.572S (L/180) 2.540 1.724 1.326 1.096 0.951 0.857 0.795S (L/150) 3.048 2.068 1.591 1.315 1.142 1.028 0.954
U 4.575 3.096 2.372 1.951 1.685 1.508 * 1.391 *S (L/250) 2.464 1.679 1.299 1.082 0.948 0.864 0.813S (L/180) 3.423 2.332 1.804 1.502 1.317 1.200 * 1.129 *S (L/150) 4.107 2.798 2.164 1.803 1.580 1.440 * 1.355 *
U 5.585 3.792 2.919 2.418 2.105 * 1.906 * 1.783 *S (L/250) 3.434 2.352 1.834 1.543 1.371 1.270 * 1.221 *S (L/180) 4.500 3.267 2.547 2.143 1.904 * 1.764 * 1.696 *S (L/150) 4.500 3.921 3.056 2.572 2.284 * 2.117 * 2.035 *
U 6.972 * 4.756 * 3.686 * 3.081 * 2.717 * 2.500 * 2.391 *S (L/250) 4.500 3.445 2.716 2.320 2.102 * 1.998 * 1.979 *S (L/180) 4.500 4.500 * 3.772 * 3.223 * 2.919 * 2.775 * 2.749 *S (L/150) 4.500 4.500 * 4.500 * 3.867 * 3.503 * 3.330 * 3.299 *
U 7.500 * 6.148 * 4.813 * 4.079 * 3.666 * 3.463 * 3.425 *S (L/250) 4.500 4.500 * 4.288 * 3.750 * 3.505 * 3.462 * 3.462 *S (L/180) 4.500 4.500 * 4.500 * 4.500 * 4.500 * 4.500 * 4.500 *S (L/150) 4.500 4.500 * 4.500 * 4.500 * 4.500 * 4.500 * 4.500 *
U 7.500 * 7.500 * 6.576 * 5.698 * 5.285 * 5.208 * 5.208 *600 900 1200 1500 1800 2100 2400
A maximum stress level of 110MPa has been applied when generating this table.
CORNER MULLION - EN9499 / EN5014 / EN9499
Mullion Height (mm)
Mullion Spacing (mm)
2900
2000
3800
Serviceability pressures for L/150 applications have been limited to a maximum Serviceability Pressure of 4500Pa.
3500
2300
3200
2600
Maximum Design Pressure (kPa)
Serviceability pressures for L/180 & L/250 applications have not been limited by water performance. Where water performance is necessary, refer to Product Specifications page.
* Indicates the "Braced Bead" (EP12761) should be used.
LEGEND: S = Serviceability Pressure, U = Ultimate Pressure
NOTE: This table is based on a combination of approved AS2047 testing data and theoretical section properties.
01-08-2013
Section 2c - Page 8
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Span Table
Note:
S (L/250) 3.000 * 1.980 1.226 0.817 0.574 0.420 -S (L/180) 3.000 * 2.347 * 1.670 * 1.134 * 0.797 0.583 0.440S (L/150) 3.000 * 2.347 * 1.670 * 1.258 * 0.957 0.700 0.528
U 3.618 * 2.347 * 1.670 * 1.258 * 0.987 0.797 0.658S (L/250) 3.000 * 2.063 1.298 0.875 0.619 0.455 -S (L/180) 3.000 * 2.456 * 1.777 * 1.215 * 0.860 0.633 0.479S (L/150) 3.000 * 2.456 * 1.777 * 1.353 * 1.032 * 0.759 0.575
U 3.671 * 2.456 * 1.777 * 1.353 * 1.069 * 0.867 0.718S (L/250) 3.000 * 2.195 * 1.401 0.953 0.679 0.502 -S (L/180) 3.000 * 2.627 * 1.927 * 1.323 * 0.943 0.697 0.530S (L/150) 3.000 * 2.627 * 1.927 * 1.480 * 1.132 * 0.836 0.636
U 3.832 * 2.627 * 1.927 * 1.480 * 1.176 * 0.958 0.796S (L/250) 3.000 * 2.390 * 1.545 * 1.059 * 0.759 0.563 0.429S (L/180) 3.000 * 2.876 * 2.134 * 1.471 * 1.054 * 0.782 0.596S (L/150) 3.000 * 2.876 * 2.134 * 1.651 * 1.264 * 0.938 0.716
U 4.118 * 2.876 * 2.134 * 1.651 * 1.318 * 1.077 * 0.898S (L/250) 3.000 * 2.677 * 1.748 * 1.206 * 0.868 0.646 0.494S (L/180) 3.000 * 3.000 * 2.425 * 1.675 * 1.206 * 0.898 0.687S (L/150) 3.000 * 3.000 * 2.425 * 1.887 * 1.447 * 1.077 * 0.824
U 4.500 * 3.239 * 2.425 * 1.887 * 1.512 * 1.240 * 1.036 *S (L/250) 3.000 * 3.000 * 2.044 * 1.418 * 1.025 * 0.765 0.587S (L/180) 3.000 * 3.000 * 2.839 * 1.970 * 1.424 * 1.063 * 0.815S (L/150) 3.000 * 3.000 * 2.847 * 2.226 * 1.708 * 1.275 * 0.978
U 4.500 * 3.775 * 2.847 * 2.226 * 1.790 * 1.472 * 1.232 *S (L/250) 3.000 * 3.000 * 2.503 * 1.744 * 1.265 * 0.946 0.727S (L/180) 3.000 * 3.000 * 3.000 * 2.423 * 1.756 * 1.314 * 1.009 *S (L/150) 3.000 * 3.000 * 3.000 * 2.745 * 2.108 * 1.577 * 1.211 *
U 4.500 * 4.500 * 3.496 * 2.745 * 2.213 * 1.823 * 1.528 *1500 1750 2000 2250 2500 2750 3000
A maximum stress level of 110MPa has been applied when generating this table.NOTE: This table is based on a combination of approved AS2047 testing data and theoretical section properties.
750
1200
900
Serviceability pressures for L/150 applications have been limited to a maximum Serviceability Pressure of 3000Pa.
Transom Width (mm)
1050
600
Serviceability pressures for L/180 & L/250 applications have not been limited by water performance. Where water performance is necessary, refer to Product Specifications page
TRANSOM 1 - EN5021
LEGEND: S = Serviceability Pressure, U = Ultimate Pressure
Transom Spacing (mm)
1500
1350
Maximum Design Pressure (kPa)
* Indicates the "Braced Bead" (EP12761) should be used.
As lowlight mullions under transom are assumed, no consideration has been given to the deadload component of loading.
01-08-2013
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2c - Page 9
400 Narrowline
Span Table
Note:
S (L/250) 3.000 * 2.536 * 1.569 * 1.046 * 0.735 0.538 -S (L/180) 3.000 * 3.000 * 2.180 * 1.453 * 1.021 * 0.747 0.564S (L/150) 3.000 * 3.000 * 2.245 * 1.692 * 1.225 * 0.896 0.676
U 4.500 * 3.156 * 2.245 * 1.692 * 1.327 * 1.071 * 0.885S (L/250) 3.000 * 2.642 * 1.663 * 1.120 * 0.793 0.583 0.442S (L/180) 3.000 * 3.000 * 2.309 * 1.556 * 1.101 * 0.810 0.614S (L/150) 3.000 * 3.000 * 2.390 * 1.820 * 1.322 * 0.972 0.737
U 4.500 * 3.303 * 2.390 * 1.820 * 1.437 * 1.166 * 0.966S (L/250) 3.000 * 2.810 * 1.794 * 1.220 * 0.869 0.642 0.489S (L/180) 3.000 * 3.000 * 2.492 * 1.695 * 1.208 * 0.892 0.679S (L/150) 3.000 * 3.000 * 2.591 * 1.991 * 1.449 * 1.071 * 0.814
U 4.500 * 3.532 * 2.591 * 1.991 * 1.581 * 1.288 * 1.071 *S (L/250) 3.000 * 3.000 * 1.978 * 1.356 * 0.972 0.721 0.550S (L/180) 3.000 * 3.000 * 2.747 * 1.883 * 1.349 * 1.001 * 0.764S (L/150) 3.000 * 3.000 * 2.870 * 2.220 * 1.619 * 1.201 * 0.916
U 4.500 * 3.868 * 2.870 * 2.220 * 1.772 * 1.449 * 1.208 *S (L/250) 3.000 * 3.000 * 2.238 * 1.544 * 1.112 * 0.828 0.633S (L/180) 3.000 * 3.000 * 3.000 * 2.145 * 1.544 * 1.149 * 0.879S (L/150) 3.000 * 3.000 * 3.000 * 2.538 * 1.853 * 1.379 * 1.055 *
U 4.500 * 4.355 * 3.261 * 2.538 * 2.034 * 1.668 * 1.393 *S (L/250) 3.000 * 3.000 * 2.618 * 1.816 * 1.313 * 0.980 0.751S (L/180) 3.000 * 3.000 * 3.000 * 2.523 * 1.823 * 1.361 * 1.043 *S (L/150) 3.000 * 3.000 * 3.000 * 2.994 * 2.188 * 1.633 * 1.252 *
U 4.500 * 4.500 * 3.828 * 2.994 * 2.407 * 1.979 * 1.656 *S (L/250) 3.000 * 3.000 * 3.000 * 2.234 * 1.619 * 1.212 * 0.931S (L/180) 3.000 * 3.000 * 3.000 * 3.000 * 2.249 * 1.683 * 1.292 *S (L/150) 3.000 * 3.000 * 3.000 * 3.000 * 2.699 * 2.020 * 1.551 *
U 4.500 * 4.500 * 4.500 * 3.691 * 2.976 * 2.451 * 2.054 *1500 1750 2000 2250 2500 2750 3000
A maximum stress level of 110MPa has been applied when generating this table.
TRANSOM 2 - EN5020 / EN9499
LEGEND: S = Serviceability Pressure, U = Ultimate Pressure
Transom Spacing (mm)
1500
1350
NOTE: This table is based on a combination of approved AS2047 testing data and theoretical section properties.
750
1200
900
Serviceability pressures for L/150 applications have been limited to a maximum Serviceability Pressure of 3000Pa.
Transom Width (mm)
1050
600
Serviceability pressures for L/180 & L/250 applications have not been limited by water performance. Where water performance is necessary, refer to Product Specifications page
Maximum Design Pressure (kPa)
As lowlight mullions under transom are assumed, no consideration has been given to the deadload component of loading.
* Indicates the "Braced Bead" (EP12761) should be used.
01-08-2013
Section 2c - Page 10
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
Maximum Glass Thickness Table - Deadload Assessment
Note:
10 8 6 4 - - - - -
10 10 6 5 - - - - -
10 10 6 5 4 - - - -
10 10 8 6 4 - - - -
10 10 8 6 5 4 - - -
10 10 10 8 6 4 - - -
10 10 10 8 6 5 4 - -
1400 1600 1800 2000 2200 2400 2600 2800 3000
2.3 2.7 3.0 3.3 3.7 4.0 4.3 4.7 5.0
10 10 10 8 6 5 4 - -
10 10 10 8 6 5 4 - -
10 10 10 10 6 6 4 - -
10 10 10 10 8 6 5 4 -
10 10 10 10 8 6 6 4 -
10 10 10 10 10 8 6 5 4
10 10 10 10 10 10 8 6 5
1400 1600 1800 2000 2200 2400 2600 2800 3000
2.3 2.7 3.0 3.3 3.7 4.0 4.3 4.7 5.0
NOTE: This table is based on theoretical section properties, not on approved tests as specified by AS2047. A deflection ratio of L/600 has been assumed, resulting in the individual deflection figures listed on the tables.
700600
TRANSOM 1 - EN5021
Height Above Transom (mm)
Transom Width (mm)600700800
Maximum Glass Thickness with Support Blocks at 1/4 Points (mm)
Glass thickness has been limited to 10mm as dictated by the capacity of the suite.These tables have been developed to assist Fabricators in making an assessment of the maximum glass thickness that the transom member can support before it is considered unstable (deflection & stress).
Wind load and human impact requirements are not included in the tables below. A glass thickness assessment for windload and human impact must still be completed in accordance with AS1288.
900100011001200
DownwardDeflection (mm)
Height Above Transom (mm)
900800
Maximum Glass Thickness with Support Blocks at 1/8 Points (mm)
120011001000
Transom Width (mm)Downward
Deflection (mm)
01-08-2013
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 2c - Page 11
400 Narrowline
Maximum Glass Thickness Table - Deadload Assessment
Note:
8 6 4 - - - - - -
10 6 4 - - - - - -
10 6 5 - - - - - -
10 8 6 4 - - - - -
10 8 6 4 - - - - -
10 10 6 5 4 - - - -
10 10 8 6 4 - - - -
1400 1600 1800 2000 2200 2400 2600 2800 3000
2.3 2.7 3.0 3.3 3.7 4.0 4.3 4.7 5.0
10 10 8 6 4 - - - -
10 10 8 6 5 - - - -
10 10 10 6 5 4 - - -
10 10 10 8 6 4 - - -
10 10 10 8 6 5 4 - -
10 10 10 10 6 6 4 - -
10 10 10 10 8 6 5 4 -
1400 1600 1800 2000 2200 2400 2600 2800 3000
2.3 2.7 3.0 3.3 3.7 4.0 4.3 4.7 5.0
NOTE: This table is based on theoretical section properties, not on approved tests as specified by AS2047. A deflection ratio of L/600 has been assumed, resulting in the individual deflection figures listed on the tables.
900100011001200
DownwardDeflection (mm)
Height Above Transom (mm)
900800
Maximum Glass Thickness with Support Blocks at 1/8 Points (mm)
120011001000
Transom Width (mm)Downward
Deflection (mm)
700600
TRANSOM 2 - EN5020 / EN9499
Height Above Transom (mm)
Transom Width (mm)600700800
Maximum Glass Thickness with Support Blocks at 1/4 Points (mm)
Glass thickness has been limited to 10mm as dictated by the capacity of the suite.These tables have been developed to assist Fabricators in making an assessment of the maximum glass thickness that the transom member can support before it is considered unstable (deflection & stress).
Wind load and human impact requirements are not included in the tables below. A glass thickness assessment for windload and human impact must still be completed in accordance with AS1288.
01-08-2013
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 3 - Page 1
400 Narrowline
Section 3 - Page 2
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 3 - Page 3
400 Narrowline
Section 3 - Page 4
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 3 - Page 5
400 Narrowline
Section 3 - Page 6
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 3 - Page 7
400 Narrowline
Extrusion Data
Ixx (103mm4) Iyy (103mm4) Zxx (103mm3) Zyy (103mm3)
EK5925 Flush Filler 0.452 1.356 0.062 0.166EN5010 Standard Frame 112.169 668.779 3.865 13.136EN5011 Heavy Duty Frame 125.145 767.577 4.254 15.062EN5014 2/3 Way Corner 1394.889 619.712 26.443 12.194EN5016 Narrow Frame 43.541 493.938 2.474 9.683EN5020 Standard Sill 88.688 561.702 3.923 10.027EN5021 Tubular Transom 138.075 544.145 5.088 9.249EN5022 Plain Frame 117.515 704.801 3.756 13.929EN5028 Flat Filler 0.736 133.104 0.150 3.328EN5029 Build In Filler 13.864 128.100 0.524 3.178EN5031 Sloping Bead 5.484 21.382 0.371 1.059EN5032 Square Bead 9.507 33.066 0.535 1.513EN9457 Lightweight Frame 99.719 588.566 3.409 11.541EN9499 Pocketed Filler 7.966 135.101 0.622 3.377EP10567 Fixing Adaptor 9.174 574.695 0.510 7.427EP12061 Reveal Fin Adaptor 12.266 146.520 0.545 3.443EP12761 Braced Bead 11.579 39.535 0.685 1.789EP4845 External Flange Frame 56.903 547.520 1.605 9.971EP5408 Light S/M Mullion 45.716 585.629 1.428 11.228EP5409 Heavy S/M Mullion 80.458 1076.423 2.745 18.905EP5447 Narrow Frame Hook Bead 0.816 0.789 0.098 0.076EQ6368 Nailing Fin Adaptor 21.188 135.920 0.645 3.635
* NOTE: The structural properties listed above are using the orientations as listed within the extrusion pages.
Structural Properties *Extrusion Description
01-08-2013
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 4 - Page 1
400 Narrowline
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 5 - Page 1
400 Narrowline
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 6 - Page 1
400 Narrowline
Section 6 - Page 2
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 6 - Page 3
400 Narrowline
Section 6 - Page 4
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 6 - Page 5
400 Narrowline
Section 6 - Page 6
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 6 - Page 7
400 Narrowline
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 7 - Page 1
400 Narrowline
GLASS SIZE WEDGE WEDGE5mm 300013 3000036mm 300013 3000136mm 315788 (CAPTIVE) 3000138mm 300001 3000138mm 315787 (CAPTIVE) 30001310mm 300001 30000110mm 315787 (CAPTIVE) 300001
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 9 - Page 1
400 Narrowline
01-08-2013
Assembly - Head Not To Scale
FRAME(MULLION/JAMB)
FRAME (HEAD)
POCKETED FILLEREN9499
150mm @ 600 CTRS
FRAME FOAM GASKET300160ALT. USE SMALL JOINT SEALANT
FRAME HEAD
10g x 25mm SS PAN SCREW300059CAULK ALL SCREW HEADS ONFRAME ASSEMBLY COMPLETION
Section 9 - Page 2
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
01-08-2013
Assembly - Sill & Internally Glazed Sill Not To Scale
SILL
FRAME(MULLION/JAMB)
SILLSILL/TRANSOM FOAM GASKET300161ALT. USE SMALL JOINT SEALANT
10g x 25mm SS PAN SCREW300059
CAULK ALL SCREW HEADS ONFRAME ASSEMBLY COMPLETION
INTERNALLY GLAZED SILL
POCKETED FILLEREN9499
150mm @ 600 CTRS
POCKETED FILLEREN9499SEAL INTO POSITIONALT. FLAT FILLER EN5028
FRAME (JAMB)
SILL/TRANSOM FOAM GASKET300161
ALT. USE SMALL JOINT SEALANT
SILL
POCKETED FILLEREN9499150mm @ 600 CTRS
BEADAPPLIED AFTER GLASS
BEADAPPLY AFTER GLASSINNERMOST LEGSEALED INTO POSITION
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 9 - Page 3
400 Narrowline
01-08-2013
Assembly - Transom Not To Scale
FRAME (MULLION)JAMB SIMILAR
POCKETED FILLEREN9499FULL LENGTH CAULKINGPRIOR TO APPLICATION
FOAM DRAIN PLUG300164 SILL / TRANSOM END GASKET
300161ALT. USE SMALL JOINT SEALANT
TUBULAR TRANSOMEN5021
10g x 25mm SS PAN SCREW300059CAULK ALL SCREW HEADS ONFRAME ASSEMBLY COMPLETION
TUBULAR TRANSOM
INTERNALLY GLAZED 2-PIECE TRANSOM
SELF MATING MULLIONSEAL BOTTOM 100mm
BEADAPPLY AFTER GLASSINNERMOST LEGSEALED INTO POSITION
FOAM DRAIN PLUG300164COMPLETELY SEAL PERIMETER
DRAIN HOLE 9mm
SILL/TRANSOM FOAM GASKET300161ALT. SMALL JOINT SEALANT
Section 9 - Page 4
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 9 - Page 5
400 Narrowline
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 10 - Page 1
400 Narrowline
Section 10 - Page 2
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 10 - Page 3
400 Narrowline
Section 10 - Page 4
This Technical Manual contains Capral priviledged information and is subject to Copyright
400 Narrowline
This Technical Manual contains Capral priviledged information and is subject to Copyright
Section 10 - Page 5
400 Narrowline