+ All Categories
Transcript

PP

PP

FEC

FEC

FEC

FEC

FEC

WH

SNACK RACK

TC

ROYAL

VISION

COOLER

REF.

VM

REF.

REF.

REF.

REF.

ROYAL

VISION

COOLER

ROYAL

VISION

COOLER

Freezer

VV16BTFNF

ROYAL

VISION

COOLER

S D

T

T

T

T

T

T T

T

T

T

T

T

T

T

T

CD

T

T

T

T

T

T

T

T

T

T

T

T

T

T

TT

T

T

T

T

T

RECEPTION

TESTING

OFFICE

HUDDLE

IT WORKRM.

LEARNING &

DEVELOPMENT

VESTIBULE

INTERVIEW

INTERVIEW

RECRUITMENT

SECURITY

LOCKERS

FITNESS ROOM

VESTIBULE

BREAK ROOM

TRAINING

PRE�FUNCTION

TRAINING

TRAINING

TRAINER

1�ON�1

TRAINING

STORAGE

TRAINER

HOTELING

MAIL

DECOMPRESSION

PANTRY/

LOCKERS

MDF

SM. CONF.LG. CONF.

PRESENTATION

SM. CONF.

TOUCHDOWN

XLG. CONF.

LG. CONF.

MEDIA

HUDDLE

SERVICE CENTER

SM. CONF.

TRAINING

WOMENS

LOCKER ROOM

MENS

LOCKER ROOM

WOMENS

RESTROOM

MENS

RESTROOM

TRAINING

TRAINING

SUPPORT

OPEN

OFFICE

STORAGE

STORAGE

OFFICE

OFFICE

OFFICE

OFFICE

JANITOR

102

105

143

139

141

129

101

103

104

106

107

116

119

121

109

111

112

130

123

125

122

120

113

140

131133

134

135

126

138

132

144

142

136

110

117

118

115

114

128

124

137

108

127A

149

148

147

146

127B

( )425 CFM

A10"

2

( )425 CFM

A10"

2

TYP

60"x24" SAFROM RTU�3

( )335 CFM

A10"

6

16"x14" SA

20"x17" SA

( )335 CFM

A10"

6

20"x17" SA

130 CFMA

6"

( )330 CFM

A10"

2

370 CFMA

10"

10"x12" SA

( )260 CFM

A8"

3

205 CFMA

6"

195 CFMA

6"

100 CFMA

6"

14"x12" SA

205 CFMA

6"( )

250 CFMA

8"4

( )310 CFM

A8"

3

350 CFMA

10"

195 CFMA

6"

( )270 CFM

A8"

2

10"x10" SA

( )260 CFM

A8"

6

50 CFMA

6"

12"x10" SA

240 CFMA

8"

115 CFMA

6"

430 CFMA

10"

205 CFMA

6"

( )285 CFM

A8"

4

( )300 CFM

A8"

2

( )290 CFM

A8"

2

( )285 CFM

A8"

7

225 CFMA

8"

130 CFMA

6"

8"x10" SA

10"x10" SA

220 CFMA

8"

( )180 CFM

A6"

2

12"x10" SA

( )320 CFM

A8"

2

12"x10" SA

12"x12" SA

205 CFMA

6"

( )80 CFM

B6"

2

8"x8" SA

3�2

FPVAV

3�1

VAV

3�3

FPVAV

3�4

FPVAV

14"ø SA 14"ø SA

3�5

FPVAV

3�6

FPVAV

3�7

FPVAV

3�8

FPVAV

3�9

FPVAV

3�10

FPVAV

3�1

FPVAV

3�2

VAV

3�3

VAV

3�4

VAV

3�5

VAV

3�6

VAV

3�7

VAV

3�8

VAV

3�10

VAV

3�11

VAV

3�12

VAV

3�13

VAV

( )50 CFM

U6"

2

3�14

VAV

2

CRAC

1

CRAC

14"x12" EA

14"x12" EA

390 CFMP

12"18"x16" EAUP TO EF�2

400 CFMP

12"

300 CFMP

10"

12"x14" EA

16"x14" EAUP TO EF�3

14"x14" EAUP TO EF�4

1

EUH

2

EUH

10"x12" SA

14"x12" SA

10"x10" SA

14"x12" SA

12"x10" SA

14"x14" SA

10"x8" SA

12"x10" SA

12"x12" SA

10"x12" SA16"x14" SA

( )335 CFM

A10"

6

10"x12" SA

16"x14" SA

20"x17" SA

10"x12" SA

16"x15" SA

14"x12" SA

16"x16" SA

2"ø G

1 1/2"ø G

1 1/4"ø G

3�15

VAV

3�16

VAV

3�17

VAV

( )280 CFM

A8"

5

( )285 CFM

A8"

5

�R

10"X22"

�R

10"X22"(4)

22"x10" TA

RTU�3

1 1/2"ø G

12

"x1

2"

SA

16

"x1

4"

SA

16

"øS

A

14

"x1

2"

SA

16

"x1

6"

SA

12"x10" SA

(2)

( )330 CFM

A10"

6

16"x16" SA

24"x18" SA

18"ø SA

12"ø SA

12"ø SA

(4)

40"x20" SA 26"x20" SA

40"x20" SA 26"x20" SA 26"x20" SA

26"x20" SA

1

1

( )320 CFM

A8"

3

3�18

VAV

12"x12" SA

16

"x1

4"

SA

3�19

VAV

3/4"ø G

1

GWH

3/4"ø G

6"ø EA

12"x12" SA

50 CFMB

6"

50 CFMB

6"

12"ø SA

MG

MG

MG

MG

MG

MG

390 CFMP

12"(2)

60 CFMQ

6"

14"x12" EA

8"ø SA

14

"x1

2"

SA

370 CFMA

10"

10"ø SA

2

3

3

MOUNT T�STAT ON CEILING

34"x18" SA

ROUTE (N) GAS PIPINGBACK TO EXISTINGTAP AT GAS METER.SEE DETAIL F/M501

1

1

24"x24" TA

24"x24" TA

24"x24" TA

1

1

1

14"x14" TA

1

16"x16" TA(2)

1

1

16"x16" TA1

10"x10" TA

1

16"x16" TA 18"x16" TA

1

14"x12" TA

1

14"x14" TA

1

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

4

1220 Marshall Street NE

Minneapolis

Minnesota 55413�1036

612.677.7100

612.677.7499 fax

www.rsparch.com

RSP Architects

Consultants

Certification

Project For

UHG Project #

UHG Location Code

Business Unit

NOTICE: The designs shown and described herein including all technical drawings,

graphics, and models thereof, are proprietary and cannot be copied, duplicated or

commercially exploited, in whole or in part, without express written permission of

RSP Architects. These are available for limited review and evaluation by clients,

consultants, contractors, government agencies, vendors and office personnel only

in accordance with this Notice.

© Copyright RSP Architects 2009. All rights reserved.

Date

Registration Number

Signature

Revisions

Project No.

Drawn By

Checked By

Date

PROJECT CONTACT:Rebecca White, Project Designer 612�677�7362

P120183

MILITARY &VETRAN

M�E Engineers, Inc.

3425 austin bluffs pkwy ste 201

colorado springs, co 80918

t. 719.536.0036/f. 719.536.0037

www.me�engineers.com

Darrell R. Lackey

31019Expiration Date

10/31/13

10/09/2012

11/13/2012 8:21:29 AM

C:\Users\dsnead\Documents\CS12015.00 2 UnitedHealth Group CS_dsnead.rvt

9945 FEDERAL DRIVE

COLORADO SPRINGS,

CO 80921

M201

MECH FLOOR PLAN AREA A

BUILDING

DRL

DES

09 October 2012

6138120183

1/8" = 1'�0"M201

1MECHANICAL FLOOR PLANAREA A

GENERAL NOTES:

1. CONTRACTOR SHALL FIELD VERIFYLOCATION AND CONDITION OF ALLEQUIPMENT PRIOR TO BEGINNING OFWORK.

2. FPVAV AND VAV CONNECTIONS ARESCHEDULED SIZE UNLESS NOTEDOTHERWISE.

3. T�STAT CONNECTION LINES TOELECTRIC COIL AND/ORCORRESPONDING VAV BOX.

4. MAINTAIN 10 FT MIN. CLEARANCEBETWEEN AIR INTAKES AND ALLEXHAUST FANS AND VENTS.

5. MOUNT THERMOSTATS AND CO2SENSORS +48" AFF.

6. REMOTE OPERATORS ON VOLUMEDAMPERS ABOVE HARD LID CEILINGS.

7. REBALANCE RTU�3 TO 6700 OA ANDRTU�4 TO 4000 OA.

Keynote Legend

Key Value Keynote Text

1 REFRIGERANT LINESSIZED BYMANUFACTURER

2 3" CA AND 3" FLUE TOCONCENTRIC VENT

3 REMOVE EXISTING 20"ROUND DUCT ANDINSTALL NEW DUCT ASINDICATED

NORTH

No. Date Description

1 10/19/2012 MODIFICATION NO. 1

3 11/05/2012 MODIFICATION NO. 3

4 11/13/2012 MODIFICATION NO. 4

FEC

FEC

FEC

FEC

FEC

.

WH

REF.

SD

S D

T

T

T

T

T T T

TT T

TT

T

T

T

T

CD

T

T

T

T

TT

T T

T

MOTHER'S SUITE

SERVICE

CENTER

HUDDLE

HUDDLE

HUDDLE

HUDDLE

ELECTRICAL

MDF

OFFICE

HUDDLE

HUDDLE

IDF

STORAGE

JANITOR

MENS

RESTROOM

WOMENS

RESTROOM

OPEN

OFFICE

OPEN

OFFICE

OPEN

OFFICE

VIRTUAL

WELL

OPEN

OFFICE

OPEN

OFFICE OPEN

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CORRIDOR

155

165

169

170

163

166

156

140

164

153

152

161

144

145

159

160

158

151154

172

157

167

168

171

149

148

147

146

150

( )280 CFM

A8"

6

( )280 CFM

A8"

6

( )280 CFM

A8"

6

( )305 CFM

A8"

6 ( )305 CFM

A8"

6 ( )305 CFM

A8"

6

10"x10" SA

10"x10" SA

10"x10" SA

10"x10" SA

10"x10" SA

16"x16" SA

16"x14" SA

12"x12" SA14"x12" SA

16"x14" SA

12"x10" SA

14"x14" SA

16"x16" SA

12"x10" SA

16"x14" SA

( )245 CFM

A8"

6

( )245 CFM

A8"

6

( )245 CFM

A8"

6

( )315 CFM

A8"

5

( )300 CFM

A8"

5

( )300 CFM

A8"

5( )

300 CFMA

8"5

16"x14" SA

12"x10" SA

40"x20" SA

4%3

FPVAV

4%2

FPVAV 110 CFMA

6"

140 CFMA

6"

245 CFMA

8"

110 CFMA

6"

110 CFMA

6"

8"x8" SA

10"x10" SA

4%1

FPVAV

4%1

VAV

4%2

VAV

4%4

VAV

4%3

VAV

4%5

VAV

4%6

VAV

4%7

VAV

4%8

VAV

50 CFMB

6"

50 CFMB

6"

145 CFMA

6"

8"x8" SA

4%9

VAV

4%4

FPVAV

16"ø SA

4%5

FPVAV

4%6

FPVAV

( )315 CFM

A8"

5

4%9

FPVAV

4%8

FPVAV

%P

18X18TYP

%P

18X18TYP

14"x14" EA

14"x14" EAUP TO EF%1 66"x30" RA

66"x30" RA

66"x30" RA

60"x24" SA

FROM TO RTU%4

66"x30" RA

UP TO RTU%4 66"x30" RAUP TO RTU%4

3

CRAC

50 CFME

8X6

5

EF

4%7

FPVAV

410 CFMP

12"

80 CFMQ

6"

135 CFMA

6"

8"x10" SA

( )135 CFM

A6"

3

10"x8" SA

8"x8" SA

110 CFMA

6"

10"x10" SA

BIRDSCREENINLET

16"ø SA

12"ø SA

CAP( )

50 CFMB

6"3

3%9

VAV

2

CRAC

4

CRAC

OFFICE

162

1 1/2"ø G

1 1/4"ø G

16"x16" SA

12"x10" SA 14"x14" SA 12"x10" SA16

"x1

6"

SA

205 CFMC

6"

205 CFMC

6"

205 CFMC

6"

205 CFMC

6"

%R

10"X22"(3)

22"x10" TA

%R

10"X22"(2)

(2)

%R

10"X22"(2)

22"x10" TA

12

"x1

0"

SA

16

"x1

4"

SA

RTU%4

12"x10" SA 14"x14" SA 12"x10" SA

16

"x1

6"

SA

14

"x1

4"

SA

16"x16" SA

16"x16" SA

14

"x1

4"

SA

14

"x1

4"

SA

16"x16" SA

12"x10" SA 14"x14" SA 12"x10" SA 12"x10" SA 14"x14" SA 12"x10" SA

12"x10" SA 12"x12" SA 14"x12" SA

16"ø SA

12

"x1

2"

SA

12

"x1

0"

SA

16"ø SA

16"ø SA

12"x10" SA 12"x12" SA 14"x12" SA

12"x10" SA 14"x14" SA 12"x10" SA

16

"x1

6"

SA

40"x20" SA26"x20" SA

16

"øS

A

16"ø SA

14

"x1

2"

SA

16

"øS

A

16

"øS

A

26"x20" SA 40"x20" SA

66"x30" RA

1

1

1

( )320 CFM

A8"

314"x12" SA 12"x12" SA16"x14" SA

( )320 CFM

A8"

3

CAP

CAP

1

EWH

16"x14" SA

10"x10" SA

12"x10" SA

W/ BIRDSCREEN

8"x8" SA

16"x16" SA

MG

MG

1

3

3

3

3

3

3

33

3

3

3

4

1220 Marshall Street NE

Minneapolis

Minnesota 55413�1036

612.677.7100

612.677.7499 fax

www.rsparch.com

RSP Architects

Consultants

Certification

Project For

UHG Project #

UHG Location Code

Business Unit

NOTICE: The designs shown and described herein including all technical drawings,

graphics, and models thereof, are proprietary and cannot be copied, duplicated or

commercially exploited, in whole or in part, without express written permission of

RSP Architects. These are available for limited review and evaluation by clients,

consultants, contractors, government agencies, vendors and office personnel only

in accordance with this Notice.

© Copyright RSP Architects 2009. All rights reserved.

Date

Registration Number

Signature

Revisions

Project No.

Drawn By

Checked By

Date

PROJECT CONTACT:Rebecca White, Project Designer 612�677�7362

P120183

MILITARY &VETRAN

M�E Engineers, Inc.

3425 austin bluffs pkwy ste 201

colorado springs, co 80918

t. 719.536.0036/f. 719.536.0037

www.me�engineers.com

Darrell R. Lackey

31019Expiration Date

10/31/13

10/09/2012

11/13/2012 8:32:02 AM

C:\Users\dsnead\Documents\CS12015.00 2 UnitedHealth Group CS_dsnead.rvt

9945 FEDERAL DRIVE

COLORADO SPRINGS,

CO 80921

M202

MECH FLOOR PLAN AREA B

BUILDING

DRL

DES

09 October 2012

6138120183

1/8" = 1'%0"M202

1MECHANICAL FLOOR PLANAREA B

GENERAL NOTES:

1. CONTRACTOR SHALL FIELD VERIFYLOCATION AND CONDITION OF ALLEQUIPMENT PRIOR TO BEGINNING OFWORK.

2. FPVAV AND VAV CONNECTIONS ARESCHEDULED SIZE UNLESS NOTEDOTHERWISE.

3. T%STAT CONNECTION LINES TOELECTRIC COIL AND/ORCORRESPONDING VAV BOX.

4. MAINTAIN 10 FT MIN. CLEARANCEBETWEEN AIR INTAKES AND ALLEXHAUST FANS AND VENTS.

5. MOUNT THERMOSTATS AND CO2SENSORS +48" AFF.

6. REMOTE OPERATORS ON VOLUMEDAMPERS ABOVE HARD LID CEILINGS.

7. REBALANCE RTU%3 TO 6700 OA ANDRTU%4 TO 4000 OA.

Keynote Legend

Key Value Keynote Text

1 REFRIGERANT LINESSIZED BYMANUFACTURER

NORTH

No. Date Description

1 10/19/2012 MODIFICATION NO. 1

3 11/05/2012 MODIFICATION NO. 3

4 11/13/2012 MODIFICATION NO. 4

DescriptionDateMark

NOTICE: The designs shown and described herein including all technical drawings,

graphics, and models thereof, are proprietary and cannot be copied, duplicated or

commercially exploited, in whole or in part, without express written permission of

RSP Architects. These are available for limited review and evaluation by clients,

consultants, contractors, government agencies, vendors and office personnel only

in accordance with this Notice.

© Copyright RSP Architects 2012. All rights reserved.

Checked By

Date

Drawn By

Project No.

1220 Marshall Street NE

Minneapolis, MN 55413#1036

Signature

Project For

Registration No.

Signing Date

Consultants

RSP Architects

Certification

BUILDING9945 FEDERAL DRIVECOLORADO SPRINGS,CO 80921

6138120183

ELE

DRH

09 OCTOBER 2012

P120183

MILITARY & VETERAN

David R. Hoag

42706

10/09/2012

10/31/13

Business Unit

UHG Project #

UHG Location Code

First Last, Project Designer

PROJECT CONTACT:

612.677.7100

612.677.7499 fax

www.rsparch.com

612#677#7XXX

Expiration Date

M�E Engineers, Inc.3425 austin bluffs pkwy, ste 201

colorado springs, co 80918

t. 719.536.0036 / f. 719.536.0037

www.me�engineers.com

AREA "A"

ELECTRICAL LIGHTINGFLOOR PLAN

E201

MODIFICATION NO. 311/05/20123

MODIFICATION NO. 411/13/20124

DescriptionDateMark

NOTICE: The designs shown and described herein including all technical drawings,

graphics, and models thereof, are proprietary and cannot be copied, duplicated or

commercially exploited, in whole or in part, without express written permission of

RSP Architects. These are available for limited review and evaluation by clients,

consultants, contractors, government agencies, vendors and office personnel only

in accordance with this Notice.

© Copyright RSP Architects 2012. All rights reserved.

Checked By

Date

Drawn By

Project No.

1220 Marshall Street NE

Minneapolis, MN 55413#1036

Signature

Project For

Registration No.

Signing Date

Consultants

RSP Architects

Certification

BUILDING9945 FEDERAL DRIVECOLORADO SPRINGS,CO 80921

6138120183

ELE

DRH

09 OCTOBER 2012

P120183

MILITARY & VETERAN

David R. Hoag

42706

10/09/2012

10/31/13

Business Unit

UHG Project #

UHG Location Code

First Last, Project Designer

PROJECT CONTACT:

612.677.7100

612.677.7499 fax

www.rsparch.com

612#677#7XXX

Expiration Date

M�E Engineers, Inc.3425 austin bluffs pkwy, ste 201

colorado springs, co 80918

t. 719.536.0036 / f. 719.536.0037

www.me�engineers.com

ELECTRICAL ONE#LINE DIAGRAM

E701

MODIFICATION NO. 110/19/20121

MODIFICATION NO. 311/05/20123

MODIFICATION NO. 411/13/20124

HP1

LDP

RP1

RP2

RP3

RP4

RP5

RP6

HP2

DescriptionDateMark

NOTICE: The designs shown and described herein including all technical drawings,

graphics, and models thereof, are proprietary and cannot be copied, duplicated or

commercially exploited, in whole or in part, without express written permission of

RSP Architects. These are available for limited review and evaluation by clients,

consultants, contractors, government agencies, vendors and office personnel only

in accordance with this Notice.

© Copyright RSP Architects 2012. All rights reserved.

Checked By

Date

Drawn By

Project No.

1220 Marshall Street NE

Minneapolis, MN 55413#1036

Signature

Project For

Registration No.

Signing Date

Consultants

RSP Architects

Certification

BUILDING9945 FEDERAL DRIVECOLORADO SPRINGS,CO 80921

6138120183

ELE

DRH

09 OCTOBER 2012

P120183

MILITARY & VETERAN

David R. Hoag

42706

10/09/2012

10/31/13

Business Unit

UHG Project #

UHG Location Code

First Last, Project Designer

PROJECT CONTACT:

612.677.7100

612.677.7499 fax

www.rsparch.com

612#677#7XXX

Expiration Date

M�E Engineers, Inc.3425 austin bluffs pkwy, ste 201

colorado springs, co 80918

t. 719.536.0036 / f. 719.536.0037

www.me�engineers.com

ELECTRICAL PANEL SCHEDULES

E702

MODIFICATION NO. 110/19/20121

MODIFICATION NO. 311/05/20123

MODIFICATION NO. 411/13/20124


Top Related