FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
WIRE ASM-AUXHOLDING TANK151316-04-000
COMPARTMENT(REF)
PLATE-COAX149557-03-CHTSCREWG39-08-08U (2)
AD
3
PANEL-SERVICE132862-04-CHTPANEL-SERVICE132862-16-CHT
DRAINAGE SYSTEM-HEATED
CONTROL-SLIDEOUT189400-01-000SCREWG39-08-12U (4)DETAIL AC
PANEL-RCP151376-02-CHTADAPTOR82134-01-000NUT82136-01-000LABEL157486-01-CHTSCREWG67-10-12U (4)
1B1
3
1.
CODES/STANDARDS-CSA/CMVSS
CODES/STANDARDS USA
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PERCODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRETIE 8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXXAS APPROPRIATE FOR INSTALLATION.
WIRE PASSES THROUGH FLOOR IN THIS AREA.
3
265
2.
REAR SIDEOF COMPARTMENT
PLACE CROSS LOCATOR ON SENSORS OVER DIMPLES ON TANK.
WIRE ASM-MAINHOLDING TANK151317-05-000
WIRE ASM-TANK HEATERTO TANK HEATER PADS
NOTES:
WIRE ASM-TANK HEATERTO TANK HEATER PAD
4
5
1B1
4
ROUTE TANK SENSOR WIRES SO THEY DO NOT PASSOVERSENSORS. USE WIRE TIE MOUNT 155366-01-000 ANDWIRE TIE 8343-01-000 AS NEEDED. TANK SURFACE MUSTBE CLEANED USING ISOPROPYL ALCOHOL AND PRIMED WITHPRIMER 94.
23T
265
AA
AB
SWITCH-WATER PUMP108357-21-000ACTUATOR108356-23-CHTWIRE ASM-EXTENSION000024236 / 31493001000
23T
WIRE ASM-HEATER,TANKS134551-15-000
CLED-1
VIEW AA
520
VIEW AC
VIEW AD
DRAINAGE SYSTEM/HEAT-PREWIRE23R
OR23R
23T23R OR
23T23R OR
SLIDEOUT WIRE WITHGREEN TAPE PASSTHROUGH FLOORIN THIS AREA
WIRE ASM-CHASSISTO WIRE ASM SIDEWALL
SLIDEOUT WIRE WITHYELLOW TAPE PASSTHROUGH FLOORIN THIS AREA
CLAMP010495-02-000 (10)SCREW000G39-06-12U (10)
WIRE ASM-SLIDEOUTMOTORS(REF)
SECURE WIRE ASM TO HOLDING TANK CRADLE ASM.
PORT-SOLAR,SINGLE191558-01-000SCREWG39-10-12U (4)
SOLAR PANEL/BATT CHARGER SYS3AA
SOLAR PANEL/BATTERY CHRG W/O29W
6 SPLICE YELLOW TO RED AND WHITE TO BLACK.
63AA
29W
3AA
4 PIN HSG(CIRCUITS: ABY,ABZ,DR,DU)
2 PIN HSG(CIRCUIT: DDJ)
6 PIN HSGWITH GREEN TAPE 6 PIN HSG
WITH YELLOW TAPE
2 PIN HSG(CIRCUITS: LLL,LLK)
LABEL-SLIDEOUT CTL098379-09-000
COVER-ELECTRICAL194965-01-CHT
7 FROM WIRE ASM-CHASSIS.7
7
7
7 7
3
UNSPECIFIED TOLERANCES: MATERIAL:
C
D
1
TWO-PLACE (X.XX)
DSNR:
DESCRIPTION:
8
2
B
ALL DIMENSIONS ARE IN MILLIMETERSDFTR:
6
A
6
FIRST USED:
A
REV
WHOLE DIM (X)
D
REF:
8
ITEM/PART NO:
4
WEIGHT: (LBS)
SHEET:
7
B
2
4
REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES
ANGLE
5
5
13
COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC.
ONE-PLACE (X.X)
C
7
WIRING INSTL-BODY,12V
1 OF 8 000178019 / 30230901000
3
1.5
0.50
1
282 SOLAR PANEL - 100 WATT
282OR
OR 282
VIEW AB
JACKS-STABILIZING, ELECTRIC64A
64A
PANEL-SWITCH000215380 / 303681-01-CHTSWITCH-ROCKER108357-06-000 (2)ACTUATOR-SWITCH108356-01-CHT (2)LABEL-STABILIZER000007799 / 310651-01-CHT
17 524G
WATERPUMP
SLID
EO
UT
RO
OM
CO
NTR
OLLE
RS
17-Jan-2017
1.
WIRE PASSES THROUGH FLOOR IN THIS AREA.
WIRE ASM-COACH000002515 / 310095-01-000
WIRE ASM-COACHTO RIGHT SIDE
2 PIN HSGTO WATER PUMP
SWITCHDETAIL EA
THERMOSTAT000016556 / 313194-01-CHT000016270 / 313193-01-CHTPLATE-SPACER,THERMOSTAT000018276 / 313583-01-CHTSCREWG11-06-08U (2)
WIRE ASM-HEATER,RELAY153891-01-000RELAY63912-02-000SCREWG11-08-12U
2
3
CODES/STANDARDS USA
23T
CODES/STANDARDS-CSA/CMVSS
DRAINAGE SYSTEM-HEATED
1B1
1B1
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PERCODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRETIE 8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXXAS APPROPRIATE FOR INSTALLATION.
265
23T
25Q29Z
NOTES:
265
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
2
2
CONTROL-WATERPUMP176001-01-000SCREWG11-08-12U (2)DETAIL BA
GB
TO WIRE ASM-SIDEWALL
SWITCHDETAIL EC
SWITCHDETAIL EJ
2 PIN HSGTO BLACK TANKSENSOR HARNESS
DRAINAGE SYSTEM/HEAT-PREWIRE23R
23R OR
DETAIL BA
GC
TO SLIDEOUT CONTROLVIEW DA
A/C ROOF-MOUNT25Q
A/C 14,800 - HEAT PUMP29Z
DETAIL BB 4
CIRCUIT FROM WIRE ASM-CHASSIS.6
4 FOR REFERENCE ONLY. SEE LOAD CENTER/ATS ASMFOR ADDITIONAL INFORMATION.
5 CIRCUIT FROM WIRE ASM-COACH.
5
6
JA
JD
JF
BBZ
NM
JG
WB
JC
JB
M
JE
J
ET
GROUND BARCIRCUITS;NE,NC,ND,PM,NF,JM,JP,JX,MS,JY,UK,FFE,EU,JN,CCA
XXZ
JA JY
YYF
10
SPEAKER124884-01-000GRILL151844-01-CHTSCREWG11-08-12U (4)
10
LPGD
SECURE ABOVE FLOOR WITH SCREW CALLED OUT.
BC
7 CENTER LIGHT STRIP.
CLEAN SURFACE WITH CLEAN TOWEL.SPEAKER-ROUND160868-01-CHT (2)SPEAKER-GRILLE,ROUND160868-02-CHT (2)SCREWG11-08-08U (8)
2 PIN HSGTO GREY TANKSENSOR HARNESS
LIGHT-TAPE,LED187693-36-CHT
TO WIRE ASM-SIDEWALL
SWITCHDETAIL EN
TOILET-TECMA,WALL SWITCH170062-02-CHT
WIRE ASM-OVHD194525-01-000
USB-CHARGER DUAL,DC188312-01-000 (2)DETAIL BD
WIRE ASM-CHASSIS(REFERENCE)
VIEW BC
56
WIRE ASM-TOILET172776-01-000TOILET-TANK SENSOR170062-03-000TOILET-SENSOR HARNESS170062-05-000
37
9
41R9 MOVE SPEAKER TO BRACKET LOCATION WITH
41R
41R SOFA/SLEEPER
BRACKET-SPEAKER194218-01-CHTSCREWG39-08-12U (4)
- +
DETAIL BD
JCNC
WIRE ASM-WATER TANK151317-04-000
8 PLACE CROSS LOCATOR ON SENSORS OVER DIMPLES ON TANK.
8
LIGHT-VANITY,CURVED LED301249-01-CHTCAP-SCREW168409-01-CHT (2)WASHER168409-02-CHT (2)SCREW000G67-10-08U (2)BRACKET-MOUNT,LIGHT000010503 / 311044-01-CHTSCREW000G39-10-16U (4)DETAIL BE
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,12V
000178019 / 30230901000 2 OF 8
TO LIGHT-TAPE,LED
WIRE ASM-RESISTOR140195-01-000
11 CENTER LAMP ABOVE MEDICINE CABINET.
11
USB-CHARGER DUAL,DC188312-01-000
DETAIL BE(LIGHT NOT SHOWN)
347
40
BRACKET-MOUNT,LIGHT(REF)
ROOF ASM(REF)
SIDEWALLASM-LEFT(REF)
CABINETASM-BATH(REF)
PANEL-COVER,SPEAKER000014799 / 311949-01-CHTSCREW000G11-10-12U (4)
14W
DINETTE14W
CONTROL-WATER HEATER000027745 / 316105-01-CHTSCREWG67-08-12U (2)
Battery GroundSwitch Load
17-Jan-2017
WL,WMTO POWER DOORLOCK ACTUATORDETAIL CB
DETAIL CB
WL(YEL)
4
WM(WHT)
CA
MONITOR PANEL175724-06-000175724-03-000SCREWG11-08-12U (4)
SWITCHESDETAIL EH
LCS-1
CIRCUITS ARE PART OF WIRE ASM-SIDEWALL.
265
CODES/STANDARDS USA
GEN-3.2 KW ONAN DIESEL33F
CODES/STANDARDS-CSA/CMVSS
1B1
CLAMP WIRES AWAY FROM FURNACE.
4
DOOR SWITCHDETAIL DD
WIRE ASM-COACHTO LEFT SIDE
1.
3
NOTES:
2651B1AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PERCODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRETIE 8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXXAS APPROPRIATE FOR INSTALLATION.
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
5
TO WIRE ASM-CHASSIS
TO COAX OUTPUTIN COMPARTMENT
SEE LOAD CENATER/ATS FOR ADDITIONAL INFORMATION.2
GENERATOR PREP KIT321
FRONT CAP W/O BED31P
VIEW CA
FRONT CAP W/BED31TMOUNTED ON EXTERIOR SURFACE OF SIDEWALL.6
SWITCHDETAIL ET
6
SWITCHDETAIL EL
1DJ EXTERIOR SPEAKER SYSTEM
SPEAKER-EXT.171547-01-CHT (2)SCREWG39-08-12U (8)
1DJ
TO WIRE ASM-SLIDEOUT
TO REFRIGERATOR
TO SIDEWALL
321
STEREO-AM/FM/DVD WALLMOUNT190332-02-000SCREW76790-03-000 (4)FILTER-GROUND LOOP123324-01-000
CROSSOVER150140-01-000CROSSOVER-COIL150140-02-000CLAMP10497-02-000SCREWG11-08-08U (4)SCREWG67-10-12U
DA
SWITCHDETAIL EF
33F
401 INVERTER-DC/AC, 1000 WATT
086 INTERIOR UPGRADE PACKAGELOAD CENTERDETAIL BB
CONVERTER-45 AMP184353-01-000SCREWG67-10-12U (4)
086
2
CROSSOVER150140-01-000SCREWG11-08-08U (4)WIRE ASM-JUMPER189827-01-000CONNECTS TO CIRCUITSHM,HN,GP,GN,MMK,MML,MMN,MMM
31P
31T
CC
PLATE-WALL,SINGLE COAX149557-13-CHT
SWITCHDETAIL EB
3
RELAY063912-02-000(AWNING LOCKOUT)
42B
42B
7 CENTER LIGHT STRIP.
CLEAN SURFACE WITH CLEAN TOWEL.
TV,REAR-WITHOUT42B
SWITCHDETAIL EDRELAY-AWNING63912-02-000
SPLICE(REF)
WATERHEATER
WIRE ASM-COACH
CONTROL-CHARGE,SOLAR 30 AMP191278-01-000SCREWG11-08-08U (2)DETAIL FB
LIGHT-TAPE, LED187693-13-CHT
3AA
LED-2
JW
JX
SOLAR PANEL/BATT CHARGER SYS
RED
BLK
SWITCHDETAIL EK
VIEW CC
SWITCHDETAIL EG
LIGHT-TAPE, LED187693-13-CHT7 5
59
PLATE-WALL149557-09-CHT
PLATE-WALL,POWER SUPPLY179004-02-CHT
PLATE-WALL,KEYSTONE175530-04-CHTCONNECTOR-HDMI179395-01-000
TO ANTENNA
DETAIL CD
ER
PLATE-WALL,KEYSTONE175530-04-CHT (2)SCREWG13-05-10U (4)
TO FURNACE
TO WATER HEATERDETAIL CD
TO ROOF
LIGHT-TAPE, LED187693-11-CHT
3AA
CLAMP-CABLE010495-02-000SCREWG11-06-12U
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,12V
000178019 / 30230901000 3 OF 8
SOLAR PANEL - 100 WATT282
282 OR
17-Jan-2017
1
MOUNT MAGNET USING PILOT HOLES IN SCREEN DOOR FRAME.MOUNT WITH MAGNET TOWARD SWITCH.
2
GROMMET8386-01-000
DETAIL DD
ROUTE WIRESTHRU HOLE
3
SWITCH/MAGNET-STEP, ELECTRIC116995-03-000SCREWG11-06-08U (4)
2
JAMB-DOOR
NOTES:
CODES/STANDARDS-CSA/CMVSS
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
MOUNT SWITCH AND SPACER TO BLOCK ON JAMB.ADJUST HEIGHT TO MATCH MAGNET.
3
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
1B1 265
1B1 CODES/STANDARDS USA
265
READ-62
WIRE ASM-SLIDEOUT194522-01-000
CLED-1
DB
VIEW DA
CONTROL-SLIDEOUT189400-01-000SCREWG67-08-12U (4)VIEW DC
BACKWALL(REF)
BOTTOM OF SLIDE ROOM FLOOR(REF)
GA
CONNECT RED WIRE TO YELLOW WIRE ANDCONNECT BLACK WIRE TO WHITE WIRE.
COVER-ELECTRICAL194965-01-CHT
LABEL-SLIDEOUT CTL098379-09-000
4 PIN HSG(CIRCUITS: ABW,ABX,BBM,BBN)
6 PIN HSGWITH BLUE TAPE
2 PIN HSG(CIRCUITS: LLR,LLP)
2 PIN HSG(CIRCUIT: DDJ)
6 PIN HSGWITH PURPLE TAPE
VIEW DC
4 FROM WIRE ASM-CHASSIS. 4
4
4
CONNECTS TOWIRE ASM-COACH HERE
4 4
GROMMET023942-01-000
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,12V
000178019 / 30230901000 4 OF 8
5 REMOVE SCREWS FROM MAGNET SWITCH TO INSTALL LOCKWASHERS AND TERMINALS.
EXTERNAL TOOTH LOCK WASHER TRI-Z000007554 / 310611-01-000 (2) 5
VIEW DB
SLID
EO
UT
RO
OM
CO
NTR
OLLE
RS
17-Jan-2017
265
1E2
1B1
ENTRANCE STEP-ELEC.
CODES/STANDARDS-CSA/CMVSS
23T
1B1
CODES/STANDARDS USA
SEE OPERATORS MANUAL
TURN OFF When Not In Use
HOLDING TANK HEATER
DETAIL EM
SWITCH-BLANK138253-01-CHTSWITCH-ROCKER135740-06-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)LABEL134563-01-CHT
HR
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
DRAINAGE SYSTEM-HEATED
SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)
PJJE
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
265
23T
23TTV SWITCH-BLANK138253-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-45-CHTSCREWG11-08-08U (2)
DETAIL EB
DETAIL EJ
DETAIL ER
SWITCH108357-18-000 (2)ACTUATOR108356-31-CHT (2)PLATE-SWITCH144363-02-CHT (2)SCREWG11-06-10U (4)
SWITCH-BATT DISC108357-18-000ACTUATOR-BATT DISC108356-19-CHTADD WIRE ASM-THERM186796-01-000
SWITCH-STEP108357-19-000
DETAIL ET
L.P.
VALVE
SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-59-CHTSCREWG11-08-08U (2)
DETAIL EE
KKDWB
DETAIL EC
SWITCH108357-21-000ACTUATOR108356-23-CHTSCREWG11-06-10U (2)PLATE-SWITCH144363-02-CHT
23R DRAINAGE SYSTEM/HEAT-PREWIRE
OR
OR
23R
23R
DETAIL EH
710 VENT ROOF-POWERED,INSULATED
316 SKYLIGHT/ROOF VENT, POWER
SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)
DETAIL EN
KKPJC
LABEL-SLIDEOUT,DRIVER,FRONT163992-01-CHT
NC
JC
SWITCH-ROCKER135740-04-CHTSWITCH-BASE135741-04-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)WIRE ASM-RESISTOR140195-01-000
JCBBG-1
DETAIL EF
SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)
DETAIL EG
JERRB
SWITCH-ROCKER135740-04-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)WIRE ASM-RESISTOR140195-01-000
JEPC-1
SWITCH-ROCKER135740-01-CHTSWITCH-BLANK138253-01-CHTSWITCH-BASE135741-02-CHTSWITCH-BEZEL135742-02-CHTSCREWG11-08-08U (4)
DETAIL EL
JCRRC
SWITCH-ROCKER135740-01-CHT135740-03-CHTSWITCH-BASE135741-02-CHTSWITCH-BEZEL135742-02-CHTSCREWG11-08-08U (4)
DETAIL EL
GGBJBKJ
KJJMGGC RRC
JC
41M 316
SWITCH-ROCKER135740-01-CHT (3)SWITCH-BASE135741-03-CHTSWITCH-BEZEL135742-03-CHTSCREWG11-08-08U (4)
DETAIL EK
JCWX
JBGGZ
JERRA
DETAIL ED
SWITCH-ROCKER108357-06-000ACTUATOR-SWITCH108356-12-CHT
PLATE-SWITCH158431-17-CHTSCREWG11-06-10U (4)
SWITCH-ROCKER108357-14-000ACTUATOR-SWITCH108356-28-CHT
PLATE-SWITCH158431-17-CHTSCREWG11-06-10U (4)
1E2
LABEL-WARNING,SLIDEOUT116549-01-000
INVERTER-DC/AC, 1000 WATT401
1JD
33F 1
SWITCHDETAIL EM
1
SWITCHDETAIL EE
SUPPLIED WITH GENERATOR.
REMOTE PANEL-INVERTER(SUPPLIEDWITH INVERTER)MODULE-12V DISC173355-01-000
NOTES:
DRAINAGE SYSTEM-HEATED-W/O1JD
401
PANEL-GENERATOR(REFERENCE)
33F GEN-3.2 KW ONAN DIESEL
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,12V
000178019 / 30230901000 5 OF 8
BBG
PC
SWITCH-ROCKER135740-01-CHT (2)135740-04-CHTSWITCH-BASE135741-03-CHTSWITCH-BEZEL135742-03-CHTSCREWG11-08-08U (4)
DETAIL EA
JEPD
JEPK
PEJE
PE-1
IN
AWNING
OUT
DRIVER'SSIDE FRONT SEE OPERATORS MANUAL
HOLDING TANK HEATERTURN OFF When Not In Use
L.P.
VALVE
CRUSH HAZARD. Keep people and objects clear of the insideand the outside of the slideout room when operating. Failureto comply could result in death or serious injury. 116549-01G
WARNING
17-Jan-2017
255
2
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
ANT-RCODES/STANDARDS-CSA/CMVSS
255
1
SEE ANTENNA INSTALLATION MANUAL FORCORRECT INSTALLATION PROCEDURE.
2
NOTES:
WRAP BRACKET LEGS AROUND ANTENNA BASE.
255
FA
VIEW FA
NFFROM WIRE ASM-COACH
BRACKET ANTENNAGROUND 1
265
RADIO/AM/FM/CD/DVD, COACH
1B1 CODES/STANDARDS USA
2651B1
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FD
FC
SOLAR PANEL/BATT CHARGER SYS3AA
DETAIL FB 3AA
WIRE ASM-COACHWIRE ASM-COACH
8 GRN & 10 WHT8 GRN
3AA
WIRE IS MARKED WITH GOLD TAPE.3
WIRE IS MARKED WITH YELLOW TAPE.4
3 4
8 BLK
5
3 8 BLK & 10 YEL
WIRE ASM-SOLAR EXT,10 FOOT195056-01-000
4
BATTERYCONNECTION SOLAR PANEL
CONNECTION
PORT-SOLAR,3 POSITION191277-01-CHTDETAIL FD
3AA
SHOWER SKYLIGHTCUTOUT (REF)
SHOWER SKYLIGHTCUTOUT (REF)
600
3AA
5
3AA
DETAIL FC
3AADETAIL FD
8 BLK TO EMPTYPOST ON30A BREAKER
5
8 GRN TO GROUND STUD(STACK GROUND WIRES)
5
WIRE ASM-COACH
PORT-SOLAR(REF)
5
260
260
950
20
PLACE ROOF SEALANT HERE(APPROXIMATELY 75MM WIDE)AND PUSH THE CABLES INTOTHE SEALANT TO STABILIZE THEM.
LIGHT-TAPE,LED,DIFFUSED190025-82-CHT
LIGHT-TAPE,LED,DIFFUSED190025-40-CHT
LIGHT-TAPE,LED,DIFFUSED190025-09-CHT
170
LIGHT-TAPE,LED,DIFFUSED190025-91-CHT
600
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,12V
000178019 / 30230901000 6 OF 8
OR
OR OR282 282
282
SOLAR PANEL - 100 WATT282
282OR
282OR3AA
COIL CABLE AND TIE TO INSIDE OF SOLARPANEL LEG WITH 008343-04-000.
6
6
PANEL-SOLAR 100 WATT191276-01-CHTMOUNTING FEET-SOLAR,QTY 4000031418 / 316962-01-000SCREWG39-10-10U (8)
PANEL-SOLAR 100 WATT191276-01-CHTMOUNTING FEET-SOLAR,QTY 4000031418 / 316962-01-000SCREWG39-10-10U (8)
PANEL-SOLAR 100 WATT191276-01-CHTMOUNTING FEET-SOLAR,QTY 4000031418 / 316962-01-000SCREWG39-10-10U (8)
ANTENNA-TV ROOF000039180 / 318992-01-CHTSCREWG67-10-12U (6)
17-Jan-2017
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
VIEW GA
VIEW GB
6 PIN HSG TOSLIDEOUT MOTORWITH YELLOW TAPE
6 PIN HSG TOSLIDEOUT MOTORWITH GREEN TAPE
WIRE ASM-SLIDEOUT MOTORS000033686 / 317602-01-000
WIRE ROUTEDBEHIND TRIM PIECEIN THIS AREA
WIRE ROUTEDBEHIND TRIM PIECEIN THIS AREA
WIRE ROUTED BELOWFLOOR ASM-SLIDEOUTIN THIS AREA
6 PIN HSG TOSLIDEOUT MOTORWITH PURPLE TAPE
6 PIN HSG TOSLIDEOUT MOTORWITH BLUE TAPE
WIRE ASM-SLIDEOUT MOTORS000033686 / 317602-01-000
CLAMP10495-01-000 (10)SCREWG39-06-12U (10)
TO SLIDEOUTCONTROL
CODES/STANDARDS-CSA/CMVSS
1B1AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PERCODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRETIE 8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXXAS APPROPRIATE FOR INSTALLATION.
NOTES:
265
2
265
1B1WIRE PASSES THROUGH FLOOR IN THIS AREA.
1.
CODES/STANDARDS USA
WIRE ROUTEDBEHIND TRIM PIECEIN THIS AREA
WIRE ROUTEDBELOW FLOORIN THIS AREA
22
WIRE ROUTEDBELOW FLOORIN THIS AREA
WIRE ROUTEDBEHIND TRIM PIECEIN THIS AREA
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,12V
000178019 / 30230901000 7 OF 8
SLIDE-ROOM CONTROL WIRES NEED TO BE SECURELY CLAMPEDON BOTH SIDES OF THE ROLLER BRACKETS.
3
3 3
15
15
20 AMP
3
20
15
15
15
15
5
15
15
11
DC BRANCH CIRCUIT
3
6
9
30 AMP MAX
AMPS
AMPS
AMPS
AC BRANCH CIRCUIT
5
8
AMPS
AMPS
AMPS
12
AMPS
MAIN
4
30 AMP MAX
AMPS
1
AMPS
7
10
30 AMP MAX
AMPS
AMPS
30 AMP MAX
AMPS
2
17-Jan-2017
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
CODES/STANDARDS-CSA/CMVSS
1B1
265
265
1B1 CODES/STANDARDS USA
SKYLIGHT/ROOF VENT, POWER316
VENT-POWER VENTILATOR41M
JM
DETAIL HA
BLK
DETAIL HA
BUTT SPLICES (2)(REFERENCE)
WIRE ASM-ROOF CAP
VENT
JBWHT
3-PINHOUSINGS
BRN
SKYLIGHTWIRING
RED
WIRE ASM-ROOF CAP
JM
JB
BUTT SPLICES (2)(REFERENCE)
41M 316
31T
31P
TO WIRE ASM-ROOF
TO WIRE ASM-ROOF
TO ROOF VENTDETAIL HA
TO ROOF VENTDETAIL HA
TO LIGHT-TAPE,LED
WIRE ASM-VENT,ROOF CAP187873-02-000
WIRE ASM-VENT,ROOF CAP187873-01-000
SPEAKER180783-01-CHT (2)SCREWG11-10-12U (8)
SPEAKER-ROUND160868-01-CHT (2)SPEAKER-GRILLE,ROUND160868-02-CHT (2)SCREWG11-08-08U (8)
READ-6
PRLED-22
FRONT CAP W/BED31T
FRONT CAP W/O BED31P
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,12V