��http://resi.lutron.com Technical Support: [email protected]
IN
TRO
DU
CTION
SP
ECIFICATIO
N &
DESIG
N
FRO
NT R
OO
M
BA
CK R
OO
M
A
PP
END
IX
Model Numbers
Input Voltage
Regulatory Approvals
Environment
Cooling Method
Heat Generated Fully Loaded
Line-Voltage Connections
Low-Voltage Wire Type
Low-Voltage Wiring Configuration
Low-Voltage Connections
Addressing
Diagnostics
ESD Protection
Surge Protection
Miswire Protection
Power-Failure Memory
Internal Timeclock
Mounting
Mounting Hole Locations
Shipping Weight (all model numbers)
H8P5-120: Wired Processor only . H8P5-D48-120: Wired Processor with one integral Dimmer Interface (D48) . H8P5-H48-120: Wired Processor with one integral Dimmer Interface (H48) . H8P5-MI-120: Wired Processor with one integral Module Interface . H8P5-MI-D48-120: Wired Processor with one integral Module Interface and
one integral Dimmer Interface (D48) .H8P5-MI-H48-120: Wired Processor with one integral Module Interface and
one integral Dimmer Interface (H48) .
120 V 50 / 60 Hz
UL, CSA, NOM
Ambient operating temperature: 0 °C to 40 °C, 32 °F to 104 °F Ambient operating humidity: 0-90% humidity, non-condensing . Indoor use only .
Passive cooling .
18 BTUs per hr .
Mates with Lutron-provided 2-pin pigtail on DIN-rail terminal block . Power switch provided on top left of processor . Terminal blocks should be tightened to 3 .5-5 .0 in .-lbs . (0 .40-0 .57 N•m)
Two pair — one pair #18 AWG (1 .0 mm2), one pair #18-22 AWG (1 .0-0 .5 mm2) twisted shield-ed — NEC® Class 2 (IEC PELV) cable .
All processors in a multi-processor system must have the inter-processor communication links connected in a daisy-chain configuration .
4-pin removable terminal block . Each of the four terminals will accept up to two #18 AWG (1 .0 mm2) wires . Up to two standard female DB-9 serial RS-232 connections and one RJ-45 standard ethernet connection .
Via DIP Switch . Counts as 1 of 16 processor addresses . See Fig. 7, pg. 96.
Power LED, Communication link power short circuit LED, Links 1-8 Tx and Rx LEDs .
Meets or exceeds the IEC 61000-4-2 standard .
Meets or exceeds ANSI/IEEE standard c62 .41 .
All terminal block inputs are over-voltage and miswire protected against wire reversals and shorts .
Lithium battery provides a minimum of ten years of data retention .
Accuracy ± 1 minute per year (specified as during data retention time) .
HWI-PNL-8: Processor mounts at bottom of panel . See Fig. 10, pg. 98. HWI-LV32-120: Processor mounts at top of enclosure . See Fig. 9, pg. 98.
See Fig. 6, pg. 96.
9 lbs . (4 .1 kg)
8 Series P5 Processors
�� Technical Support • 24 Hours a Day/7 Days a Week • 1.800.523.9466
IN
TRO
DU
CTION
SP
ECIFICATIO
N &
DESIG
N
FRO
NT R
OO
M
BA
CK R
OO
M
A
PP
END
IX
8 Series P5 Processors (cont .)
Power Switch
Power Cord
Contact Closure Inputs
ConfigurationSwitch
Ethernet Port
Configuration DIP Switches
DIP Switch OFF ON
1 Normal Mode Boot Mode
2 User-Configured 9600 Baud Baud Rate
3-6 Address
Processor Board (all models)
Dimmer Hub (H8P5-H48-120, H8P5-D48-120,
H8P5-MI-H48-120(shown), and
H8P5-MI-D48-120 only)
Link Identification Label
Mounting Keyhole Mounting Keyhole Manual Override Switch
RPM harness connector (H8P5-MI-120, H8P5-MI-H48-120, and H8P5-MI-D48-120 only)
RPM harness (H8P5-MI-120, H8P5-MI-H48-120, and H8P5-MI-D48-120 only)
#16-24 AWG (1 .5 mm2- 0 .5 mm2) Wiring
Mounting Hole
hWI-MI-120
Figure � - 8 Series P5 Processor (h8P5-MI-h48-120 shown)
Figure � - Address DIP Switch Settings (configure switch S1)
Example: Setting Switch #6 ON.
OFF - Left
ON -Right
��http://resi.lutron.com Technical Support: [email protected]
IN
TRO
DU
CTION
SP
ECIFICATIO
N &
DESIG
N
FRO
NT R
OO
M
BA
CK R
OO
M
A
PP
END
IX
8 Series P5 Processors (cont .)
9 .95 in(252 .81 mm)
11 .96 in(303 .66 mm)
10 in(254 mm)
0 .93 in (23 .61 mm)
1 in (25 .4 mm)
11 .56 in (293 .6 mm)
5 .93 in (150 .61 mm)
Figure � – 8 Series P5 Processor Dimensions
25⁄16 in(59 .6 mm)
Front View Side View
�� Technical Support • 24 Hours a Day/7 Days a Week • 1.800.523.9466
IN
TRO
DU
CTION
SP
ECIFICATIO
N &
DESIG
N
FRO
NT R
OO
M
BA
CK R
OO
M
A
PP
END
IX
Figure � – Mounting location in an hWI-lv32-120
Control WiringEntry (Class 2)
Preferred PowerWiring Entry
HomeWorks Processor
HNN
H
NG
Control Wiring Entry (NEC Class 2; IEC PELV)
Preferred PowerWiring Entry
Alternate Power Wiring Entry
HomeWorks Processor
31⁄4 in (8 .25 cm)
Figure 10 – Mounting location in an hWI-PNl-8
8 Series P5 Processors (cont .)