Mandatory Rules InstallationInstallation
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Mandatory RulesRules Description Requirement
1 Operate IF board’s ODU-PWR switch accurately .
Before turning the toggle lever switch, you must pull it out slightly.
Otherwise, the switch will be broken, and the project will be delayed.
Every team, every member should and must know it.
2 Do not remove or insert the IF Jumper when the ODU is powered on.
Before removing or inserting the IF Jumper, you must power off the ODU (turn off the switch of IFE2 ODU-PWR).
Otherwise, the board will be damaged, and the project will be delayed.
Every team, every member should and must know it.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Mandatory Rules• Before turning the toggle lever switch, you must pull i t out slightly.
•The damaged boards by wrong operation method.
•The right operation method.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Mandatory Rules• Before removing or inserting the IF Jumper, you must power off the ODU.
• Do not remove or insert the IF cable when the ODU is powered on.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Mandatory Rules• Before removing or inserting the IF Jumper, you must power off the ODU.
• Do not remove or insert the IF cable when the ODU is powered on.
•IF cable is easy to short on the tower, it will damage the IFE2 if power is ON.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Mandatory Rules• Before removing or inserting the IF board, you must power off the ODU.
• Do not remove or insert the IF board when the ODU is powered on.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Mandatory Rules• Don’t open the ODU, and don’t tear up the seal.
• Move and install the ODU carefully.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
CONTENTS
Mandatory Rules Installation
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Installation– Before You StartChecking the Power SystemItems that need to be checked include the AC power system and the DC power system.Table Checklist for the power system
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
IDU Installation
Power Specifications RTN 910 RTN 950
power consumption (with typical configuration) (W)
52 (without microwave)114 (with microwave)
90(without microwave)203 (with microwave)
Maximum power consumption (W)
95 (without microwave)176 (with microwave)
218 (without microwave)495 (with microwave)
Voltage range (V, DC) - 38.4 to - 72.0 - 38.4 to - 72.0
Maximum current (A)2.6 (without microwave)5 (with microwave)
6 (without microwave)14.3 (with microwave)
Fuse dimenssion 12 A 20 A
• RTN 900 Power Specification
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
IDU Installation
RTN 910 RTN 950
Weight
(kg)
Empty chassis: 1.97 Empty chassis: 2.80
Dimensio
n
442 mm (width) x 220 mm (depth) x 1 U (height, 1 U = 44.45 mm).
442 mm (width) x 220 mm (depth) x 2 U (height, 1 U = 44.45 mm).
•The OptiX RTN 900 can be installed in the following:
- ETSI cabinet (300 mm deep)- ETSI cabinet (600 mm deep)- 19 inch cabinet (450 mm deep)- 19 inch cabinet (600 mm deep)- Open rack- Wall- Desktop
• RTN 900 Hardware Structure
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
IDU Installation steps• Installing the IDU in a 19’’ Rack
PGND
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
IDU Installation• Installing the IDU in a ETSI Rack
For ETSI rack, RTN 900 IDU should install transfer fixer.
For ETSI rack, RTN 900 IDU should install PGND cable ahead, then install the IDU in the rack..
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
IDU Installing
WarningThe conductor of power cable must insert the connector completely, prevent getting an electrical shock!
• Installing the Power Cable
If the power cable isn’t assembled in factory, it needs to be made in site.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
IDU Installing• For 1+1, the IF cable between IFE2 and ODU should be connected correctly.
Working IFE2 IF cable can’t connect with standby ODU.
Slot3: working board.Slot4: protection board.
working protection
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
IDU Installing• Installing the E1 Cable
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
IDU Installing• Installing the E1 Cable
•The table of all pin assignments is packed with the cable.E1 cable installing should according to it.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
IDU Installing• Installing the E1 Cable
•The table of all pin assignments is packed with the cable.E1 cable installing should according to it.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
IDU Installing
Interface on the Front
Panel
Interface Type
Usage Remark
1 ETH OAM RJ-45 10Base-T/100Base-TX NM Ethernet interface or NM serial interface
For WEBLCT
2 CLK1/TOD1 RJ-45 External clock/time input/output interface
3 CLK2/TOD2 RJ-45 External clock/time input/output interface
4 EXT/S1 RJ-45 10Base-T/100Base-TX extended Ethernet interface or 64k transparent data interface
5 PHONE RJ-45 Orderwire interface
6 ALMI/ALM0 RJ-45 3 x alarm inputs and 1 x alarm output interface
7 FE1 - FE4 RJ-45 Input/output interface for FE electrical signals
For FE service
8 E1(1 - 16) Anea 96 E1 service input/output interface For E1 service
• CXPA/CXPB Cable Interface
1 2 3 4 5 6 7 8
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
IDU Installing• EF8T/EF8F Cable Interface
• EF8T: Accesses 8 x FE electrical signals.
• EF8F: Accesses 8 x FE optical signals.
• EF8T: 8 x FE electrical signals.
• EF8F: 8 x FE electrical signals.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
IDU Installing• Cable Routing and Sequence (from 1 to 4).
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Installation– ODU
Installing an ODU on an Antenna
In this case, use four latches to mount an ODU on the back of the antenna.Follow the steps below:
1 Installing the AntennaFollowing the instructions packed with it, install the antenna.
2 Setting the Antenna PolarizationBy default, the antenna applies vertical polarization. If horizontal polarization is required, rotate the feed boom at the back of the antenna to change the polarization direction of the antenna.
3 Installing the ODU on the AntennaUse four latches to mount the ODU on the antenna.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Setting the Antenna PolarizationBy default, the antenna applies vertical polarization. If horizontal polarization is required, rotate the feed boom at the back of the antenna to change the polarization direction of the antenna.
Installation– ODU
ProcedureStep 1 Check if the antenna is vertically polarized.
Step 2 Loosen the fixing bolts enough to allow the feed boom to rotate freely.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Step 3 Rotate the feed boom 90 degrees to the right or left until its positioning pin plugs into the positioning slot in the base.
Figure Horizontally polarized antenna
Installation– ODU
Step 4 Tighten the fixing bolts.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Installing the ODU on the Antenna
Installation– ODU
ProcedureStep 1 Remove the protective caps from the feed boom of the antenna and from the ODU antenna interface. Apply appropriate lubricant to the gasket of the feed boom.
Step 2 Place the ODU antenna interface against the feed boom. Slowly fit the feed boom in to make the four ODU latches engage the four antenna hooks.
Figure Installing the ODU on the antenna (vertically polarized)
Next page
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Installation– ODU
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Installing Two ODUs on an Antenna
Installation– ODU
In this case, use a hybrid coupler to mount two ODUs on the back of the antenna.
Setting the Antenna Polarization
By default, the antenna applies vertical polarization. If horizontal polarization is required, rotate the feed boom at the back of the antenna to change the polarization direction of the antenna.
Step 1 Check the polarization direction of the antenna.If The antenna is vertically polarized, Go to the next step.The antenna is horizontally polarized, Go to Step 3.
Step 2 Remove the protective cap from the antenna interface on the coupler. Replace the polarization converter in the interface by a horizontal polarizer.
Procedure
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Step 3 Remove the protective caps from the feed boom and the antenna interface. Apply appropriate lubricant to the gasket of the feed boom.
Installation– ODU
Figure 4Installing the ODU on the hybrid coupler
Step 4 Close the four latches cornerwise.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Installation– ODU Cables
Installing the ODU Protection Grounding Cable
ProcedureStep 1 Fix the OT terminal of the protection grounding cable onto the grounding stud of the ODU.
Step 2 Connect the other end of the protection grounding cable to the grounding point on the tower thatis the nearest to the ODU.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Installing the IF CableOne end of the IF cable is connected to the ODU, while the other end is connected to the IF jumper from the IDU.
Installation– ODU Cables
ProcedureStep 1 Depending on the distance between the IDU and the ODU, cut off a length of IF cable with a slack of 3 m to 5 m.
Step 2 Refer to A Terminating the IF Cable with Connectors, make a connector for the end that is connected to the ODU.Take protective measures for the connector to avoid damage to the connectors during installation.
Step 3 Affix temporary labels to both ends of the IF cable.
Step 4 Leave enough slack of the IF cable for routing and binding it along the mast, wiring ladder and wiring frame.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Installation– ODU Cables
Figure 5-2 Waterproof curves before the IF cable enters the IDU room
Step 5 Insert the type-N male connector of the IF cable to the IF interface of the ODU and screw tight.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Figure 5-3 Connecting the IF cable to the ODU
Installation– ODU Cables
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Grounding the IF Cable In general, the IF cable should be grounded to a minimum of three points. When the IF cable is longer than 60 meters, add a grounding point for every extra 50 meters. The place about 1 m away from the ODU and 1 m away from the cable entry are propositional grounding point. All of outdoor connector should be waterproofed.
1,2,3,4:IF Cable Grounding Point.
The 3 grounding kits must be mounted.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Check IF Cable Installation
The angle between IF cable and grounding cable is the smaller the better.
The angle should <15°.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Check IF Cable Installation
You should scrape the paint on the iron before mounting the grounding kits.
HUAWEI TECHNOLOGIES CO., LTD. Page 37Huawei Confidential
Check IF Cable InstallationPorthole: IF cable must be up-tilted or have Waterproof curve in the entrance of porthole.The IF cable route and position for the cabling should be designed beforehand and arranged neatly. IF cable turns should be smooth, and the bending radius should be larger than 30 cm.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Check IF Cable Installation
All of outdoor connector should be waterproofed.
The ODU IF interface should be waterproofed.
The area for grounding kit should be waterproof.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Check IF Cable Installation
The operation of waterproof must be regular.
Wrapping a layer of PVC tape.
Wrapping three layers of waterproof insulation tape.
Wrapping three layers of PVC tape over the waterproof insulation tape.
Using the outdoor bundling strap to bind the PVC tape tight at both ends.