TRUMPF
SCHEMATICSSCHEMATICS
IEC / English
Trumpf GmbH + Co. KGJohann Maus Strafle 2
D-71254 Ditzingen
Tel.: 07156/303-0www.TRUMPF.com
TLF 1500 .. 3800 standard
Overview* Wiring diagram
- Page list
- System components
- PLC reference list
- Terminal list
* Equipment parts list- Maximum parts list (all alternatives / all options)
* Installation- Installation plans, if req.
- Pictures, if required
- Assembly instructions, if req.
TRUMPF
gepr.Name
533FEATH08000327-FEATH
LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:cover sheet
= system + site
Drawing Number:
97073-5-202
page
from page951
Id.-Nr.:
922074
29.03.00
--------------------------------------------------------------------------------| P A G E L I S T |--------------------------------------------------------------------------------| Page | Page Description | Location || | Page Description | |----------------------------------------------------------------------------------------------------------------------------------------------------------------| Installation: L |--------------------------------------------------------------------------------| 1 | cover sheet | |--------------------------------------------------------------------------------| 2 | general section | || | el.operating conditions | |--------------------------------------------------------------------------------| 3 | general section | || | device identification | |--------------------------------------------------------------------------------| 4 | general section | || | group overview | |--------------------------------------------------------------------------------| 5 | options | |--------------------------------------------------------------------------------| 6 | options | |--------------------------------------------------------------------------------| 7 | options | |--------------------------------------------------------------------------------| 8 | incoming supply | 1 |--------------------------------------------------------------------------------| 9 | incoming supply | 1b |--------------------------------------------------------------------------------| 10 | incoming supply | 1 |--------------------------------------------------------------------------------| 11 | door switch -monitoring | 1 |--------------------------------------------------------------------------------| 12 | door switch -monitoring | 1b |--------------------------------------------------------------------------------| 13 | 230V before main switch | 2 || | cabinet lighting | |--------------------------------------------------------------------------------| 14 | 230V before main switch | 2b || | cabinet lighting | |--------------------------------------------------------------------------------| 15 | power supply | 4 || | unit I 24V DC | |--------------------------------------------------------------------------------| 16 | power supply | 4 || | unit II 24V DC | |--------------------------------------------------------------------------------| 17 | potential distribution | 4 || | 24V DC | |--------------------------------------------------------------------------------| 18 | potential distribution 24V DC | 4 || | =L+59-X6 ( resonator ) | |--------------------------------------------------------------------------------| 19 | control voltage | 4 || | 110V/230V AC; FI | |-------------------------------------------------------------------------------- continued on page 2
TRUMPF
Name
533FEATHPage List
000327-FEATH
08 OHNE_ORTBLATTRevision-Number
Promis:
APPR.
Print date:
drawnby
date
Project Title:
Page Title:TLF 1500..3800 turbo
97073-5-202
1
922074
= system + site
Drawing Number: Id.-Nr.:
page
page95from
97073-5-202.8 29.03.00RevisionIndex
--------------------------------------------------------------------------------| P A G E L I S T |--------------------------------------------------------------------------------| Page | Page Description | Location || | Page Description | |----------------------------------------------------------------------------------------------------------------------------------------------------------------| 20 | service socket | 4 || | hour meter | |--------------------------------------------------------------------------------| 21 | turbine 1 | 5 |--------------------------------------------------------------------------------| 22 | switch cabinet | 9 || | cooling | |--------------------------------------------------------------------------------| 23 | power supply | 10 || | RF generator 1 | |--------------------------------------------------------------------------------| 24 | power supply | 10 || | RF generator 1 | |--------------------------------------------------------------------------------| 25 | high voltage on | 10 || | RF 1 | |--------------------------------------------------------------------------------| 26 | high voltage on | 10 || | RF 1 | |--------------------------------------------------------------------------------| 27 | RF generator control | 10 || | RF generator 1 | |--------------------------------------------------------------------------------| 28 | supply module | 17 || | ( vacuum pump ) | |--------------------------------------------------------------------------------| 29 | supply module | 17 |--------------------------------------------------------------------------------| 30 | supply module | 17 |--------------------------------------------------------------------------------| 31 | resonator | 19 |--------------------------------------------------------------------------------| 32 | resonator | 19 |--------------------------------------------------------------------------------| 33 | resonator | 19 |--------------------------------------------------------------------------------| 34 | safety circuit | 22 || | CPU-emergency stop | |--------------------------------------------------------------------------------| 35 | safety circuit | 22 |--------------------------------------------------------------------------------| 36 | safety circuit | 22 |--------------------------------------------------------------------------------| 37 | safety circuit | 22 |--------------------------------------------------------------------------------| 38 | safety circuit | 22 |--------------------------------------------------------------------------------| 39 | safety circuit | 22 || | | |-------------------------------------------------------------------------------- continued on page 3
TRUMPF
Name
533FEATHPage List
000327-FEATH
08 OHNE_ORTBLATTRevision-Number
Promis:
APPR.
Print date:
drawnby
date
Project Title:
Page Title:TLF 1500..3800 turbo
97073-5-202
2
922074
= system + site
Drawing Number: Id.-Nr.:
page
page95from
97073-5-202.8 29.03.00RevisionIndex
--------------------------------------------------------------------------------| P A G E L I S T |--------------------------------------------------------------------------------| Page | Page Description | Location || | Page Description | |----------------------------------------------------------------------------------------------------------------------------------------------------------------| 40 | laser | 22 || | service mode | |--------------------------------------------------------------------------------| 41 | laser warning lamp | 23 |--------------------------------------------------------------------------------| 42 | connection TASC-Terminal | 29 |--------------------------------------------------------------------------------| 43 | connection TASC-200 | 30 || | connection bit-bus module | |--------------------------------------------------------------------------------| 44 | connection Prozess I/O | 30 || | connection I/O card | |--------------------------------------------------------------------------------| 45 | connection I/O card 1 | 30 |--------------------------------------------------------------------------------| 46 | connection I/O card 2 | 30 || | Interface DIGITAL | |--------------------------------------------------------------------------------| 47 | LASER cooling | 47 || | power connection | |--------------------------------------------------------------------------------| 48 | LASER cooling | 47 || | control | |--------------------------------------------------------------------------------| 49 | power supply machine | 60 || | 400V / 460V | |--------------------------------------------------------------------------------| 50 | Interface | 60 || | machine | |--------------------------------------------------------------------------------| 51 | Interface | 60 || | machine | |--------------------------------------------------------------------------------| 52 | Interface | 60 || | machine | |--------------------------------------------------------------------------------| 53 | Interface DIGITAL | 60 || | machine | |--------------------------------------------------------------------------------| 54 | Interface DIGITAL | 60 || | machine | |--------------------------------------------------------------------------------| 55 | Interface DIGITAL | 60 || | machine | |--------------------------------------------------------------------------------| 56 | actuator sensor interface | 999 || | gas supply | |--------------------------------------------------------------------------------| 57 | overview of connectors | 999 |-------------------------------------------------------------------------------- continued on page 4
TRUMPF
Name
533FEATHPage List
000327-FEATH
08 OHNE_ORTBLATTRevision-Number
Promis:
APPR.
Print date:
drawnby
date
Project Title:
Page Title:TLF 1500..3800 turbo
97073-5-202
3
922074
= system + site
Drawing Number: Id.-Nr.:
page
page95from
97073-5-202.8 29.03.00RevisionIndex
--------------------------------------------------------------------------------| P A G E L I S T |--------------------------------------------------------------------------------| Page | Page Description | Location || | Page Description | |----------------------------------------------------------------------------------------------------------------------------------------------------------------| 58 | overview of connectors | 999 |--------------------------------------------------------------------------------| 59 | overview of connectors | 999 |--------------------------------------------------------------------------------| 60 | layout diagram TCO-HF1 | INFO_10 || | card in RF generator | |--------------------------------------------------------------------------------| 61 | safety circuit | INFO_22 || | ( schematic diagram ) | |--------------------------------------------------------------------------------| 62 | safety circuit | INFO_22 || | ( explanation ) | |--------------------------------------------------------------------------------| 63 | layout diagram | INFO_30/10 || | bit-bus module | |--------------------------------------------------------------------------------| 64 | bit-bus module | INFO_30/10 || | Typ 2 (Siemens) | |--------------------------------------------------------------------------------| 65 | control layout | INFO_30 || | TASC 200 | |--------------------------------------------------------------------------------| 66 | control layout | INFO_30 || | TASC 200 | |--------------------------------------------------------------------------------| 67 | layout diagram | INFO_30 || | I/O card 1 | |--------------------------------------------------------------------------------| 68 | layout diagram | INFO_30 || | I/O card 2 | |--------------------------------------------------------------------------------| 69 | layout diagram | INFO_30 || | Prozess I/O | |--------------------------------------------------------------------------------| 70 | layout diagram CPU M17 | INFO_30 |--------------------------------------------------------------------------------| 71 | layout diagram | INFO_30 || | basisboard | |--------------------------------------------------------------------------------| 72 | layout diagram Back-Plane | INFO_30 |--------------------------------------------------------------------------------| 73 | cable survey diagram | INFO_59 || | control cables | |--------------------------------------------------------------------------------| 74 | cable survey diagram | INFO_59 || | supply leads | |--------------------------------------------------------------------------------| 75 | cable survey diagram | INFO_59 || | supply leads | |-------------------------------------------------------------------------------- continued on page 5
TRUMPF
Name
533FEATHPage List
000327-FEATH
08 OHNE_ORTBLATTRevision-Number
Promis:
APPR.
Print date:
drawnby
date
Project Title:
Page Title:TLF 1500..3800 turbo
97073-5-202
4
922074
= system + site
Drawing Number: Id.-Nr.:
page
page95from
97073-5-202.8 29.03.00RevisionIndex
--------------------------------------------------------------------------------| P A G E L I S T |--------------------------------------------------------------------------------| Page | Page Description | Location || | Page Description | |----------------------------------------------------------------------------------------------------------------------------------------------------------------| 76 | ground | INFO_59 |--------------------------------------------------------------------------------| 77 | ground | INFO_59 |--------------------------------------------------------------------------------| 78 | switch cabinet layout | INFO_59 || | ( maximum extension TLF3800) | |--------------------------------------------------------------------------------| Installation: IO |--------------------------------------------------------------------------------| 1 | PLC List | OHNE_ORT |--------------------------------------------------------------------------------| 2 | PLC List | OHNE_ORT |--------------------------------------------------------------------------------| 3 | PLC List | OHNE_ORT |--------------------------------------------------------------------------------| 4 | PLC List | OHNE_ORT |--------------------------------------------------------------------------------| 5 | PLC List | OHNE_ORT |--------------------------------------------------------------------------------| Installation: KLEMPLAN |--------------------------------------------------------------------------------| 1 | =L+59-X1 | 59 || | KLEMMENPLAN | |--------------------------------------------------------------------------------| 2 | =L+59-X2 | 59 || | KLEMMENPLAN | |--------------------------------------------------------------------------------| 3 | =L+59-X3 | 59 || | KLEMMENPLAN | |--------------------------------------------------------------------------------| 3.1 | =L+59-X3 | 59 || | KLEMMENPLAN | |--------------------------------------------------------------------------------| 4 | =L+59-X6 | 59 || | KLEMMENPLAN | |--------------------------------------------------------------------------------| 4.1 | =L+59-X6 | 59 || | KLEMMENPLAN | |--------------------------------------------------------------------------------| 5 | =L+60-X41.2 | 60 || | KLEMMENPLAN | || | | || | | || | | || | | || | | || | | || | | || | | |-------------------------------------------------------------------------------- end of list
TRUMPF
Name
533FEATHPage List
000327-FEATH
08 OHNE_ORTBLATTRevision-Number
Promis:
APPR.
Print date:
drawnby
date
Project Title:
Page Title:TLF 1500..3800 turbo
97073-5-202
5
922074
= system + site
Drawing Number: Id.-Nr.:
page
page95from
97073-5-202.8 29.03.00RevisionIndex
1 2 3 4 5 6 7 8
Option47.1/7.1
Option47.2/7.2
laser model : TLF 1500 .. 3800 OEM
el.operating conditions
- voltage : 400V +10% -10% 460V +10% - 5%
following deviations from nominal values are permitted1.)
2.)
standard
- frequency : +/-2%
max. power : *)
max. current : *)
max. back-up fuse : *)
min. feeder line : *)
max. power laser
max. power chiller : 1.) 26 kVA (L16/29TR)18 kVA (L14/16TR)
35 qmm
100 A
21 kVA (L15/21TR)
TLF 24002200
2500
54 KVA
78 A
33,5 KVA
TLF 30002600, 2700
57 KVA
82 A
36 KVA
TLF 38004000
72 KVA
104 A
125 A
50 qmm
46 KVA
rated power special chiller : 2.)25kVA
control voltage :
model RF generator :
model frequency converter :
system voltage / frequency
6 A
24 V DC
15 KW
12 A
11 KW 18 KW 22 KW
33 A
400V/50Hz or 460V/60Hz
max. power plate-type exchangermax. power cooling tower
*) laser with chiller , without machine complete as required
(for 400V/50Hz bzw. 460V/60Hz)
(acc. to VDE standard 0100; 430/09.92)
TLF 1500700, 1200
44 KVA
64 A
80 A
25 qmm
25 KVA
TLF 18001700
46 KVA
66 A
80 A
25 qmm
26,5 KVA
TRUMPF
gepr.Name
533FEATH08000327-FEATH
LTLF 1500..3800 turbo
el.operating conditions
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:general section
= system + site
Drawing Number:
97073-5-202
page
from page952
Id.-Nr.:
922074
29.03.00
Code letters for type of unit
(as per DIN 40 719, part 2)
conductor cables
A :
B :
C :
E :
F :
G :
H :
K :
L :
M :
N :
P :
Q :
R :
S :
T :
V :
W :
X :
Y :
Z :
red
blue
orange
light blue
green-yellow
white
= TC 500 + 1 - K1
system siteDIN code
number
sub-assemblies
converters
capacitors
miscellaneous
fuses and automatic circuit breakers
generators and power supply units
signalling systems
relays, contactors
reactors
motors
amplifiers
measuring devices
circuit breakers and disconnect switches
resistors
switches and keys
transformers
semi-conductors
cables
plugs and sockets, terminals
brakes, clutches, valves
filters, suppressors
main circuits for D.C. and A.C. voltage
control circuits for A.C. voltage
control circuits for D.C. voltage
external cables, connected to circuit
neutral conductors of main circuits
safety earth conductor
analog ground
black :
:
:
:
:
:
:
(group)
device identification
L2 24V DC 220V ACL1 L3
wire cross-section
All unmarked wires for 24V DC are 0,5sq.mm blue.All unmarked wires for 230V AC are 1,5sq.mm red.
for contactor coilsfor motors
interference suppressors
TRUMPF
gepr.Name
533FEATH08000327-FEATH
LTLF 1500..3800 turbo
device identification
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:general section
= system + site
Drawing Number:
97073-5-202
page
from page953
Id.-Nr.:
922074
29.03.00
group number
1
2
4
5
9
10
group overview
description group number description
incoming supply / door switch - monitoring
cabinet lighting
voltage supply
turbine
switch cabinet cooling
RF generator 1
22
23
30
29
47
17
19
59
60
safety circuit
laser warning lamp
control panel (TASC-Terminal)
LASER cooling
supply module ( vacuum pump )
resonator
general section
Interface machine
999 overview of connectors
control (TASC 200)
INFO_xy schematic diagram / information
TRUMPF
gepr.Name
533FEATH08000327-FEATH
LTLF 1500..3800 turbo
group overview
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:general section
= system + site
Drawing Number:
97073-5-202
page
from page954
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
Option1.1
/22.3/23.1/24.5
Option1.3
/8.4/11.7/11.2
Option1.2
/10.4/21.1/22.3/23.1/24.5/24.5
Option1.4
/8.4/10.7/49.4
Option2.2
/8.5/11.3/13.6/14.6
Option4.2
/19.5
Option4.1
/20.7
Option4.3
/19.7/20.4
Option2.1
/8.5/13.2/14.2
Option1.5
/9.1/12.2/14.4/49.3
options
syst
em v
olta
ge 4
00V
50Hz
undervoltage tripping
syst
em v
olta
ge 4
60V
60Hz
syst
em v
olta
ge (
400V
50H
z /
460V
60H
z)
befo
re m
ain
swit
ch
cabinet lighting
faul
t-cu
rren
tprotective switch
hour meter 60Hz
service socket JIC
230V
bef
ore
main
swi
tch
inco
ming
sup
ply
400/
460V
wit
hout
mai
n sw
itch
abo
ve m
achi
ne
TRUMPF
gepr.Name
533FEATH08000327-FEATH
LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:options
= system + site
Drawing Number:
97073-5-202
page
from page955
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
Option19.1
/31.2/32.6
Option19.2 Option19.3
/37.5/39.3
Option19.4
/31.5
Option23.2
/41.5/41.2
Option23.1
/41.6/41.2
Option22.1
/31.8/34.3
Option19.5
/33.4
Option17.1
/29.2/30.3/30.2
Option9.2
/8.5/11.4/22.7/22.5
Option9.1
/22.2
options
alignment laser diode
alignment laser diode
only for TLC1005
beam tube ventilation
beam
tub
e ch
eck
lase
r wa
rnin
g la
mpmachine
key switch JIC
lase
r wa
rnin
g la
mpre
sona
tor
DC-
isol
atio
n am
plif
ier
gas
mixe
r
swit
ch c
abin
et c
ooli
ngchiller
swit
ch c
abin
et c
ooli
ngheat exchanger
TRUMPF
gepr.Name
533FEATH08000327-FEATH
LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:options
= system + site
Drawing Number:
97073-5-202
page
from page956
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
Option60.3
/43.7/66.4
Option60.1
/49.2
Option60.2
/46.8/52.8/53.8/54.8/55.8/58.6/58.6/59.5/66.5
Option47.2
/2.8/47.4/48.2
Option47.1
/2.8/47.4/48.2
Option47.3
/47.4/48.6/48.7/48.5
options
conn
ecti
on m
achi
ne
....
BCD-
Inte
rfac
e
fibr
e-op
tic
cabl
eBI
T-BU
S-In
terf
ace
conn
ecti
on c
hill
er
connection special chiller
central
cool
ing
syst
em
TRUMPF
gepr.Name
533FEATH08000327-FEATH
LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:options
= system + site
Drawing Number:
97073-5-202
page
from page957
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
PE
/11.2/12.2/13.1/13.2/14.1/14.2/15.1/15.1/16.3/17.1/19.1/21.1/23.1/24.1/44.1/47.1/49.1
1L2
/10.1/21.1/24.1/47.1/49.1
1L1
/10.1/21.1/24.1/47.1/49.1
1L3
/10.1/21.1/24.1/47.1/49.1
0L1
/10.6/11.1/13.1
0L2
/10.6/11.1/13.1
0L3
/10.6
Option1.3/5.2
Option2.1/5.4
Option1.4/5.3
Option2.2/5.5
Option9.2/6.2
-S1
1 3 5
2 4 6
/11.6
Cu busbar 30x560mm-System
see page 2
-DIN VDE 0113 T.1 section 4.3.2: Neutral conductor (N) used only with consent of user
-DIN VDE 0113 T.1 section 5.2.1: overcurrent prot.device required in supply line
-Instantaneous overcurrent trip :A set of fuses :A
-observe safety measuresspecified by local elec.company
incoming supplysystem voltage
400V 50Hz / 460V 60Hz
see page 2
only for and / or
and / or
and / or and / or
2,5qmm short-circuit-prooforange IEC / gelb JIC
"Caution! Live part although main switch off."
All devices before the main switchmust be identified as follows :
TRUMPF
gepr.Name
533FEATH08000327-FEATH
1LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:incoming supply
= system + site
Drawing Number:
97073-5-202
page
from page958
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
-X1 L1 L2 L3 PE +60-MASCHINE
0.L2
/10.6/12.1/14.1
0.L1
/10.6/12.1/14.1
0.L3
/10.6
PE
/11.2/12.2/13.1/13.2/14.1/14.2/15.1/15.1/16.3/17.1/19.1/21.1/23.1/24.1/44.1/47.1/49.1
1L2
/10.1/21.1/24.1/47.1/49.1
1L1
/10.1/21.1/24.1/47.1/49.1
1L3
/10.1/21.1/24.1/47.1/49.1
+60b-X3
1 2 3
Option1.5/5.4
/11.7
Cu busbar 30x560mm-System
see page 2
incoming supplywithout main switch
above machine400V 50Hz / 460V 60Hz
see page 2
only for
-DIN VDE 0113 T.1 section 4.3.2: Neutral conductor (N) used only with consent of user
-DIN VDE 0113 T.1 section 5.2.1: overcurrent prot.device required in supply line
-Instantaneous overcurrent trip :A set of fuses :A
-observe safety measuresspecified by local elec.company
"Caution! Live part although main switch off."
All devices before the main switchmust be identified as follows :
TRUMPF
gepr.Name
533FEATH08000327-FEATH
1bLTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:incoming supply
= system + site
Drawing Number:
97073-5-202
page
from page959
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
1L1/9.81L2/9.81L3/9.8
0L1/8.60L2/8.70L3/8.7
0L12
/49.4
0L13
/49.4
0L11
/49.4
Option1.4/5.3
-Q3
1
2
3
4
5
65A
2L3
/10.3/15.1/23.1/24.5/28.2
2L1
/10.3/15.1/19.1/22.1/23.1/24.5/28.2
2L2
/10.3/15.1/19.1/22.1/23.1/24.5/28.2
3L3
/23.1/24.5
3L1
/23.1/24.5
3L2
/23.1/24.5
-T2 5KVAPrim:460VSek:400V
Option1.2/5.2
2L1/10.22L2/10.22L3/10.2
-Q1
1
2
3
4
5
640A
-Q2
1
2
3
4
5
610A
2,5qmm
connection400V 50Hz / 460V 60Hz
before main switch
2,5qmm short-circuit-prooforg IEC / yel JIC
connection400V 50Hz / 460V 60Hz
connection 400V50Hz / 60Hz
2,5qmm
2,5qmm10qmm
TRUMPF
gepr.Name
533FEATH08000327-FEATH
1LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:incoming supply
= system + site
Drawing Number:
97073-5-202
page
from page9510
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
0L2/8.70L1/8.6
-F1
1
22A
-T1
1
3
*
5
**
4
2
6
100VA*31 **36: Prim. 400V*33 **37: Prim. 460VSek. 24V AC
-S2
13
14
+60-X3 7
-K113
14
+60-X3
6
+60-MASCHINE
Option1.3/5.2
+59-X2
5
+59-X2
6
-Q4
1
2
3
4
5
60.24A
+59-X2
L14
-S1213
14
-S1113
14
-S1013
14
-S913
14
+59-X2
1
+59-X2
2
+59-X2
3
+59-X2
4
-K1A1
A2-S1
+59-X2
L014
+60-X3
8 9
+60-MaschinePE/9.8+59
-X2
PE
+59-X2
05
Option2.2/5.5
Option9.2/6.2
U
Option1.3/5.2
.4
1 2
3 4/22.5/22.5/22.5.7
5 6
13 14
21 22 /13.531 32
43 44
/9.6/12.7
/8.1
/13.3
1,5qmmorg IECyel JIC
"Caution! Live part although main switch off."
All devices before the main switchmust be identified as follows :
1,5qmmorg IECyel JIC
key switchin service modeswitch cabinet
jumper, ifnot present
door switchrear / control side
door switchrear / RF generator
door switchfront / RF generator
door switchfront / power side
switch cabinetdoors closed
1,5qmm ge-gn
VDE 0113Teil 9.4.3.1 und Teil 8.2
ground
and / or and / oronly for
TRUMPF
gepr.Name
533FEATH08000327-FEATH
1LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:door switch -monitoring
= system + site
Drawing Number:
97073-5-202
page
from page9511
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
+59-X2.
L14
-S1213
14
-S1113
14
-S1013
14
-S913
14
+59-X2.
1
+59-X2.
2
+59-X2.
3
+59-X2.
4
-K1A1
A2
+59-X2.
L014
PE/9.8+59-X2.
PE
+59-X2.
05
U+60
-MASCHINE
-K113
14
0.L2/9.60.L1/9.6
-Q4
1
2
3
4
5
60.24A
-T1
1
3
*
5
**
4
2
6
100VA*31 **36: Prim. 400V*33 **37: Prim. 460VSek. 24V AC
-F1
1
22A
+60b-X3 6 7
Option1.5/5.4
1 2
3 4/22.6/22.6/22.6.7
5 6
13 14
21 22 /14.531 32
43 44
.4
/11.7/31.4
"Caution! Live part although main switch off."
All devices before the main switchmust be identified as follows :
door switchrear / control side
door switchrear / RF generator
door switchfront / RF generator
door switchfront / power side
switch cabinetdoors closed
1,5qmm ge-gn
VDE 0113Teil 9.4.3.1 und Teil 8.2
ground
switch cabinetdoors closed
only for
1,5qmmorg IECyel JIC
1,5qmmorg IECyel JIC
TRUMPF
gepr.Name
533FEATH08000327-FEATH
1bLTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:door switch -monitoring
= system + site
Drawing Number:
97073-5-202
page
from page9512
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
0L2/8.70L1/8.6
PE/9.8
Option2.2/5.5
-Q1
1
2
3
4
5
62.5A
-T1
1
3
*
5
**
4
2
6
800VA*31 **36: Prim. 400V*33 **37: Prim. 460VSek. 230V
PE/9.8
-F1
1
24A
+59-X2
PE
+59-X2
06
+59-X2
L015
+60-X3
4 5
+60-Maschine
+59-X2
L15
+59-X2
PE +59-X2
PE
-E1
L1 PE
N
-E2
L1 PE
N
+59-X2
7Option2.1
/5.4
+1-K1
21
22
/11.4
/11.3
1,5qmm ge-gn
1,5qmmorg
ground VDE 0113Teil 9.4.3.1 ,Teil 8.2
All devices before the main switchmust be identified as follows"Caution! Live part although main switch off."
230V before main switchmax. 400 VA
(cabinet lighting ,CO2- fire extinguisher )
TRUMPF
gepr.Name
533FEATH08000327-FEATH
2LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:230V before main switch
cabinet lighting
= system + site
Drawing Number:
97073-5-202
page
from page9513
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
0.L2/9.60.L1/9.6
PE/9.8
Option2.2/5.5
-Q1
1
2
3
4
5
62.5A
-T1
1
3
*
5
**
4
2
6
800VA*31 **36: Prim. 400V*33 **37: Prim. 460VSek. 230V
PE/9.8
-F1
1
24A
+59-X2.
PE
+59-X2.
06
+59-X2.
L015
+1b-K1
21
22
+59-X2.
PE +59-X2.
PE
-E1
L1 PE
N
-E2
L1 PE
N
+59-X2.
7
Option2.1/5.4
Option1.5/5.4
1,5qmm ge-gn
1,5qmmorg
ground VDE 0113Teil 9.4.3.1 ,Teil 8.2
only for
All devices before the main switchmust be identified as follows"Caution! Live part although main switch off."
TRUMPF
gepr.Name
533FEATH08000327-FEATH
2bLTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:230V before main switch
cabinet lighting
= system + site
Drawing Number:
97073-5-202
page
from page9514
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
1L-
/17.1
PE/9.8
+59-X3
1L-
+59-X3
01
+59-X3
PE
-F1
1
26A
-F2
1
26A
-F4
1
26A
-F5
1
26A
2L1/10.22L2/10.22L3/10.2PE/9.8
+22-K1
1
2
3
4
5
6
1L+
/17.1
2L+
/17.1
5L+
/17.1
7L+
/42.1
4L+
/17.1
-Q1
1
2
3
4
5
61.2A
-G1 L1 L2 L3 PE
M M L+
3AC400V/500V
360V-550V47Hz-63Hz
NETZTEIL
25,5V±0,5V
Ausgangsspannung
Ausgangsstrom max. 20A DC
/34.3
6qmmblu
1,5qmm sw
6qmmgrn-yel
ground VDE 0113Teil 9.4.3.1 ,Teil 8.2
safety monitoringSPS-inputs
outputs 2. I/O card
supplyTASC-Terminal
HF-power
outputs1. I/O card
1,5qmmblu
TRUMPF
gepr.Name
533FEATH08000327-FEATH
4LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:power supplyunit I 24V DC
= system + site
Drawing Number:
97073-5-202
page
from page9515
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
-G2
9 1110
2 3 4 5 6 7 81
+59-X3
6L+
6L+
/17.1
+59-X3
6L-
6L-
/17.1
+59-X3
L0 +59-X3
L10
+59-X3:L10/19.5+59-X3:L0/19.4
+59-X3
6L-
+59-X3
06
+59-X3
PE
PE/9.8
+ -0 110 220
voltage supply+24V DC II
1,5qmm gn-ge
TRUMPF
gepr.Name
533FEATH08000327-FEATH
4LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:power supply
unit II 24V DC
= system + site
Drawing Number:
97073-5-202
page
from page9516
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
1L+/15.42L+/15.5
PE/9.81L-/15.2
4L+/15.55L+/15.6
+59-X3:1L+
/18.2/29.1/31.1/45.1/48.1/49.6/56.2
6L+/16.26L-/16.2
+59-X3
1L+
+59-X3:2L+
/25.1/26.1/27.4/40.1
+59-X3
2L+
+59-X3:4L+
/35.1/41.1/48.1
+59-X3
4L+
+59-X3:5L+
/21.5/21.6/22.7/26.1/34.2/38.3/40.6/43.1/44.1/46.1/49.6
+59-X3
5L+
+59-X3:1L-
/18.2/21.7/22.7/25.1/26.1/27.4/28.3/31.1/34.3/35.2/36.1/37.1/38.1/40.1/41.1/41.5/41.5/42.1/43.1/44.1/45.1/46.1/48.1/49.6/50.1/52.8/56.2
+59-X3
1L-
+59-X3:PE
/18.2/20.1/20.4/22.1/28.2/28.6/42.1/43.1/44.1/48.1/49.6/52.8/56.2
+59-X3
PE +59-X3
6L+
+59-X3
6L-
+59-X3:6L+
/28.5/33.2
+59-X3:6L-
/33.2
potential distribution terminal block +59-X3
TRUMPF
gepr.Name
533FEATH08000327-FEATH
4LTLF 1500..3800 turbo
24V DC
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:potential distribution
= system + site
Drawing Number:
97073-5-202
page
from page9517
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
+59-X3:1L+/17.1+59-X3:1L-/17.5+59-X3:PE/17.6
+59-X6:PE
/31.1
+59-X6
PEPE
+59-X6:1L-
/31.1/32.2/41.5/48.6
+59-X6
1L-
B9 B10
+59-X6:1L+
/31.1/32.2/38.3/39.1
+59-X6
1L+
+59-X5
A9 A10
potential distributionterminal block +59-X6 ( resonator )
TRUMPF
gepr.Name
533FEATH08000327-FEATH
4LTLF 1500..3800 turbo
=L+59-X6 ( resonator )
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:potential distribution 24V DC
= system + site
Drawing Number:
97073-5-202
page
from page9518
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
2L1/10.22L2/10.2
L40_110
/20.4
Option4.3/5.7
+59-X3
PE
PE/9.8
-T11
3
*
4
**
5
2
6
800VA*31 **36: Prim. 400V*33 **37: Prim. 460VSek. 230V
-Q2
1
2
3
4
5
62.5A
+59-X3:L10
/16.1/20.1/20.7/22.1/23.8/28.6/33.4/41.1
+59-X3
L10
-F10
1
24A
+59-X3
03
+59-X3:L0
/16.1/20.1/20.4/20.7/22.1/23.8/28.6/33.4/41.3/43.1
+59-X3
L0
L20
/43.1
-Q4
1
2
3
4
I>
30mA
Option4.2/5.6
13
14
21
22
service socket JIC110V AC
ground VDE 0113Teil 9.4.3.1 ,Teil 8.2
1,5qmm gn-ge
1,5qmm sw
1,5qmm rt
supply 230V AC
open jumper at
TRUMPF
gepr.Name
533FEATH08000327-FEATH
4LTLF 1500..3800 turbo
110V/230V AC; FI
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:control voltage
= system + site
Drawing Number:
97073-5-202
page
from page9519
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
+59-X3:L10/19.5+59-X3:L0/19.4+59-X3:PE/17.6
+59-X3
L10
L40_110/19.7+59-X3:L0/19.4+59-X3:PE/17.6
-X2
Option4.3/5.7
+59-X3:L0/19.4
+59-X3:L10/19.5
Option4.1/5.6
L0PE
-X1
-F11
1
24A
-P1 h
+5-K1
13
14
/21.7
service socket IEC230V AC
service socket JIC110V AC
hour meter50 Hz
60Hz
TRUMPF
gepr.Name
533FEATH08000327-FEATH
4LTLF 1500..3800 turbo
hour meter
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:service socket
= system + site
Drawing Number:
97073-5-202
page
from page9520
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
-K213
14
-X1
1 2 3 PE
-M1
U V W PE
M3~
turbine400V / 460V
***kW44000U/min
-R1
-X1
5 64
+30-BE2
31E-Karte 1
E103.5nominal frequency
reachedturbine 1
+30-BE2
30E-Karte 1
E103.3no frequency
converter faultturbine 1
-A1
L1 L2 L3 PE
U V W PE +U -U PE G OH
20 11 19 26 14
3 1 23 21 222
13 185
-A21 2 3 gn-ge br bl
U V W PE PE
+30-XE2
31
+30-XE2
30
+59-
X3:5
L+/1
7.4
+59-
X3:5
L+/1
7.4
1L1/9.81L2/9.81L3/9.8PE/9.8
-Q1
1
2
3
4
5
6*A
-A3
L1 L2 L3
L1'
L2'
L3'
PEPE
-K11
2
3
4
5
6
-T1 5KVAPrim:460VSek:400V
-K1A1
A2
+30-BA2
33
A-Karte 1
A102.0
system voltageturbine 1 on
+30-XA2
33
+59-X3:1L-/17.5
-K2A1
A2
+30-BA2
11
A-Karte 1
A102.7
turbine 1start
+30-XA2
11
Option1.2/5.2
.8
13 14
23 24.4
/25.5
33 34
43 44
/45.2 /45.2
13
14
21
22
/22.7
.7
1 2
3 4.1.1.1/20.7
5 6
13 14
/45.2 /45.2
RESET START RFRG +24V +15V
RLB RLC RLA FLC FLA FLB
**qmm sw
0V COMIA
FU 6 FU 12 FU 33TLF 1500 TLF 1800
TLF 2400
TLF 3800
LeistungTurbine
+5-A3present ?
TLF 3000
11 kW
---
3,6 kW
---
Querschnitt 10 qmm
Einstellwert+5-Q1 *
**
***
2,5 qmm1,5 qmm
1 kW
40 A20 A10 A(28..40A)(14..20A)(7..10A)
**qmm sw
**qmm sw
+5-T1present ? ------
jumper from Pin14 auf Pin5 ------
only for
TRUMPF
gepr.Name
533FEATH08000327-FEATH
5LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:turbine 1
= system + site
Drawing Number:
97073-5-202
page
from page9521
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
2L1/10.22L2/10.2
+59-X3:PE/17.6+59-X3:L0/19.4+59-X3:L10/19.5
-A1
L1 N PE
+59-X3
L10
L0 PE
Option9.1/6.1
-S12
5
3
+59-X3:5L+/17.4
+59-X3:1L-/17.5
+30-BE2
27E-Karte 1
E102.6no excess currentprot.circuit braker
andno
excess temp.in switch cabinet
+30-XE2
27
-Q113
14
+5-Q1
13
14
Option9.2/6.2
+17-Q1
13
14
-Q1
1
2
3
4
5
64A
Option9.2/6.2
+1-K1
1
2
3
4
5
6
-A2
400V
460V
L2/N PE
1 2
Option1.1/5.1
Option1.2/5.2
400V460V
L2PE
/45.2
.4
13
14
21
22
.7
/21.1
/28.2/11.4
M1~
switch cabinetcooling
heat exchanger 230V
switch cabinet -temperature -monitoring
model SK3110setting 50½C
frequency converterturbine
climate door 1700W
vacuum pump
**)
M1~
*)
5 x 1,5 qmm
switch cabinetcooling
chiller ( climate door ) 1700W400V / 460V
3
2
230V
N
line voltage adaption
*)
**)
TRUMPF
gepr.Name
533FEATH08000327-FEATH
9LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:switch cabinet
cooling
= system + site
Drawing Number:
97073-5-202
page
from page9522
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
2L1/10.22L2/10.22L3/10.2PE/9.8
3L2/10.43L3/10.4
3L1/10.4Option1.2/5.2
Option1.1/5.1
+59-
X3:L
10/1
9.5
+59-X3:L0/19.4
13 146 7 11 12
-Q3
1
2
3
4
5
60,6A
PE
13 146 7 11 12 PE
-X2
1 2 3
-Q1
1
2
3
4
5
6** A
4 5
-Q2
1
2
3
4
5
62,8A
-K71
2
3
4
5
6-K7
43
44
-X21
1 2 3 4 5
-K713
14
-HF-1 X21_
1
X21_2
X21_3
X21_4
X21_6
X21_5
X21_7
X21_
11
X21_
12
X21_
13
X21_
14
X21_PE
13
14
21
22
/26.7
13
14
21
22
/26.7
13
14
21
22
/26.7
/26.3/26.3/26.3
/24.3
1,5qmm sw
+10-W2
1,5qmm sw
18x1,5qmm
1,5qmm sw
HF-GeneratorTyp
TLFTyp
+10-Q1
IS 11
IS 15
IS 18
IS 22
700,1200
1700
2200
2600,2700
4000
1500
1800
2400
3000
3800
2500
1,0 A
0,32 A
power supplyfilament a.grid
400V
power supplyheating output stage
400V
power supplyelectronics
400V
power supplyRF generator230V AC
TRUMPF
gepr.Name
533FEATH08000327-FEATH
10LTLF 1500..3800 turbo
RF generator 1
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:power supply
= system + site
Drawing Number:
97073-5-202
page
from page9523
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
-K81
2
3
4
5
6
-X2
8 9 10
-K111
2
3
4
5
6-R4 -R5 -R6
-X21
8 9 10
2L1/10.22L2/10.22L3/10.2
3L2/10.43L3/10.4
3L1/10.4Option1.2/5.2
Option1.1/5.1
-K41
2
3
4
5
6
-K31
2
3
4
5
6
-X4
1 2 3 PE
-HF-1 X20_
7
X20_
8
X20_
9
X20_PE
X21_8
X21_9
X21_10
-K51
2
3
4
5
6-R1 -R2 -R3
1L1/9.81L2/9.81L3/9.8PE/9.8
-Q5
1
2
3
4
5
6**A
-Q4
1
2
3
4
5
6**A
-K13L1 L2 L3 X1 X2
Spannungsasymmetrie20 %
Option1.2/5.2
/26.3
/26.5
/25.5
/25.5
/26.2
13
14
21
22
/26.7
13
14
21
22
/26.7
1112
14/26.7
/23.3/27.2
1,5qmm sw
power supplytransistor driver stage
400V
+10-W2
10qmm sw
power supplyhigh voltage400V / 460V
+10-W3
HF-GeneratorTyp
TLFTyp
IS 11
IS 15
IS 18
IS 22
700,1200
1700
2200
2600,2700
4000
1500
1800
2400
3000
3800
2500
33 A
55 A
50 A
45 A
8,5 A
3,5 A
+10-Q5
+10-Q4
2,5qmmshort-circuit-proof
open jumper at
only forRF generator model IS22
TRUMPF
gepr.Name
533FEATH08000327-FEATH
10LTLF 1500..3800 turbo
RF generator 1
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:power supply
= system + site
Drawing Number:
97073-5-202
page
from page9524
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
-K3A1
A2-K4
A1
A2-K2
A1
A2-K1
A1
A2
-K221
22-K1
21
22
+30-BA2
12
A-Karte 1
A102.5
high voltageon
automatikmode
+30-BA2
30
A-Karte 1
A102.6
high volt.onservicemode
+30-XA2
12
+30-XA2
30
+30-BE2
34E-Karte 1
E104.2enableswitchbeam on
+59-X3
2L+
+22-K4
51
52
-K213
14
+22-K7
33
34
-K113
14
+22-K7
81
82
+30-XE2
34
+59-X3:2L+/17.2
+5-K2
43
44
-K753
54
+22-K2
13
14
+22-K4
13
14
+19-S2
12
11
+59-X6
128
+59-X6
127
+59-X3
23
+59-X3
21 PE
+59-X3:1L-/17.5
+59-X3
20
-S1
ws gr
br sw
+59-X5 C8
+59-X5
C7
+22-K4
61
62
+22-K5
81
82
+22-K6
81
82+22-K6
33
34
+22-K5
51
52
+59-X3
22 PE
-S1bl
rt
1 2
3 4/24.3/24.3/24.3/26.2
5 6
13 14
/41.2/35.2/35.7
31 32
41 42
23 24
1 2
3 4/24.3/24.3/24.3/26.2
5 6
13 14
/41.2/35.2/35.7
31 32
41 42
23 24
13 14 .3.621 22
/35.231 32
43 44
.7
.7
13 14 .4.721 22
/35.231 32
43 44
.6
.6
/45.2 /45.2
/45.2/38.2 /38.2
/38.2
/40.3 /40.3
/21.8
/26.3
/35.2
/32.5
/40.4/40.4
/40.2/40.2
.8
.2
high voltageon
automatikmode
high volt.onservicemode
enable switch
high volt.onservicemode
TASC-Terminal
high volt.onservicemode
high voltage onRF
high voltage onRF
TRUMPF
gepr.Name
533FEATH08000327-FEATH
10LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:high voltage on
RF 1
= system + site
Drawing Number:
97073-5-202
page
from page9525
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
+59-X3:5L+/17.4+59-X3:2L+/17.2
-K523
24
+30-BE2
9E-Karte 1
E102.7no
voltage losshigh volt.
RFRF generator 1
+30-BE2
29E-Karte 1
E103.1high voltage on
RF 1
+30-XE2
9
+30-XE2
29
-K313
14
-K413
14
-K813
14
+30-BA2
31
A-Karte 1
A102.4
filamenta.gridvolt.on
+30-XA2
31
-K5A1
A2
+59-X3:1L-/17.5
-K8A1
A2-K11
A1
A2-K7
A1
A2
-Q113
14
-Q213
14
-Q313
14
-Q413
14
-Q513
14
-K1311
14
.2
1 2
3 4/24.3/24.3/24.35 6
13 14
.8/35.231 32
41 42
23 24 /45.2 /45.2
/25.5
/25.5
.3
1 2
3 4/24.6/24.6/24.6.5
5 6
13 14
/45.2
1 2
3 4/24.6/24.6/24.65 6
13 14
1 2
3 4/23.4/23.4/23.4/23.3
5 6
13 14
21 22
/23.343 44
53 54
31 32
/25.5
/23.3
/23.4
/23.6
/24.3
/24.6
/24.4
jumperstarting resistors
high voltage
power amplifiertransistor driver stage
on
jumperstarting resistors
transistor driver stagefilamenta.gridvolt.on
only forRF generator model IS22
TRUMPF
gepr.Name
533FEATH08000327-FEATH
10LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:high voltage on
RF 1
= system + site
Drawing Number:
97073-5-202
page
from page9526
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
HF-1
LWLS
/43.
5BB1LWLS/43.5
U601
/44.
2
-HF-1
X30_
1
X30_14
X30_
9
X30_22
X30_12
X30_13
X30_10
X30_15
X30_24
X30_
7
X30_20
X30_11
+30-BA2
2
A-Karte 1
A104.7
resetRF generator
+30-BAE1
31 30 29
Prozess I/O
set pointamplitude H.F.
ANA0+30
-BAE14
Prozess I/O
radio frequencyon
DigA100.0
+30-XANEA
31 30 29
+30-XDEA
4 13
+30-XA2
2
+59-X3
18 19
HF-EIN/31.6
-X1
1 14 9 22 12 13 10 15 2411
+59-X3:1L-/17.5+59-X3:2L+/17.2
-X30.2
1 14 9 22 12 13 10 15 2411
+10-
X1:7
/36.
4
+10-X1:20/36.5
7 20
7 20
Geh.
Geh.
/45.2
/44.2 /44.2
/24.3 S E
gr bl
set pointamplitude H.F.
radio frequencyon
resetRF generator
voltage supply24V DC
sum errorand door switchsafety circuit
TCO-HF1
E
sw
HF-Oszilator
bit-bus moduleoscillator
fibre-optic cableoscillator
13
safety circuitlaser
+10-W1
TRUMPF
gepr.Name
533FEATH08000327-FEATH
10LTLF 1500..3800 turbo
RF generator 1
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:RF generator control
= system + site
Drawing Number:
97073-5-202
page
from page9527
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
-Q1
1
2
3
4
5
61,2A
-K11
2
3
4
5
6
-M1
U V W PE
M3~
vacuum pump 0,37kWstar 380-480V
max. 1,05A1430 U/min / 50Hz1750 U/min / 60Hz
-X1
1 2 3 PE
+30-XA2
14
+30-BA2
14
A-Karte 1
A102.1
vacuum pump on
-X4.1 1 2 PE
-B1
1 2 PE
+30-XANEA
18 17 16
+30-BAE1
18 17 16Prozess I/O
actual valuesystem pressure
ANE0+59-X3:1L-/17.5
2L1/10.22L2/10.22L3/10.2
+59-X3:PE/17.6
+59-X3
L10
L0 PE
-X2
1 2 PE
-E2
fan220V42W
2700U/min
+59-X3:L0/19.4+59-X3:L10/19.5
+59-X3:PE/17.6
-K1A1
A2
4 3 2 5
-X4
Geh.
+59-X3:6L+/17.7
13
14
21
22
/22.7
.3
1 2
3 4.2.2.2/29.1
5 6
13 14
/45.2
/44.2
M1~
TRUMPF
gepr.Name
533FEATH08000327-FEATH
17LTLF 1500..3800 turbo
( vacuum pump )
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:supply module
= system + site
Drawing Number:
97073-5-202
page
from page9528
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
+30-BA2
16
A-Karte 1
A101.6
vacuumsystemopen
+30-XA2
16
+59-X11
14
-Y71
2
+59-ASI1
14
+59-ASI1
4.2
+30-BA2
17
A-Karte 1
A101.4
pump outgear chamber fast
+30-XA2
17
+59-X11
3
-Y61
2
+59-ASI1
3
+59-ASI1
4.4
+59-ASI1 4.
3
+30-BA2
18
A-Karte 1
A101.2
pump outslow
+30-BA2
36
A-Karte 1
A101.3
pump outfast
+30-XA2
18
+30-XA2
36
+59-X11
16
+59-X11
8
-Y41
2-Y5
1
2
+59-ASI1
16
+59-ASI1
8
+59-ASI1
3.4
+59-ASI1
3.2
+59-ASI1 3.
3
-Y81
2
+59-ASI1
7
+59-ASI1
1.2
+59-X11
7
+59-X11 17
+59-ASI1 17
-S11
2P
+59-ASI1
5.1
+59-ASI1 5.
4
Option17.1/6.2
+59-ASI1
+
ASI5,1/30.1
-K113
14
-Y11
2
+59-ASI1 1.
3
+59-X3:1L+/17.1
+59-X11
15
+59-ASI1
15
+59-ASI1
1.4
+59-ASI1
-
+59-ASI1 2.
3
+30-BA2
19
A-Karte 1
A101.0
gas mixslow
+30-XA2
19
+59-X11
5
-Y21
2
+59-ASI1
5
+59-ASI1
2.4
+30-BA2
37
A-Karte 1
A101.1
gas mixfast
+30-XA2
37
+59-X11
4
-Y31
2
+59-ASI1
4
+59-ASI1
2.2
/45.2/45.2/45.2 /45.2/45.2 /45.2
/28.3
Tee-adapter BTee-adapter ATee-adapter A Tee-adapter BTee-adapter B
Tee-adapter A
Tee-adapter A
slow gearboxevacuation
fill gasaccumulator
Tee-adapter A Tee-adapter B
TRUMPF
gepr.Name
533FEATH08000327-FEATH
17LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:supply module
= system + site
Drawing Number:
97073-5-202
page
from page9529
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
-S51
2P
+30-XE2
7
+59-ASI1 7.
2
+59-ASI1 10
+59-X11 10
+30-BE2
7E-Karte 1
E102.3systempressure<1100hPa
-S41
2P
+30-XE2
25
+59-ASI1 6.
2
+59-ASI1 13
+59-X11 13
+30-BE2
25E-Karte 1
E102.2gas pressureHE >4000hPa
-S31
2P
+30-XE2
6
Option17.1/6.2
+59-ASI1 6.
4
+59-ASI1 2
+59-X11 2
+30-BE2
6E-Karte 1
E102.1gas pressureCO2 >4000hPa
-S21
2P
+30-XE2
24
+59-ASI1 5.
2
+59-ASI1 9
+59-X11 9
+30-BE2
24E-Karte 1
E102.0gas pressureN2 >4000hPa
Option17.1/6.2
+59-ASI1
+
ASI5,1/29.3 +59-ASI1
7.1
+59-ASI1
6.1
/45.2/45.2/45.2/45.2
Tee-adapter B
Tee-adapter A
Tee-adapter B
TRUMPF
gepr.Name
533FEATH08000327-FEATH
17LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:supply module
= system + site
Drawing Number:
97073-5-202
page
from page9530
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
+59-X6:1L+/18.2+59-X3:1L+/17.1
+4-X3
25
+59-X6
1L-
-Y11
2
+59-X6
124
+59-X5
C4
+22-K4
71
72
+30-BA2
35
A-Karte 1
A101.5
shutteropen
+30-XA2
35
+4-X3
24
Option22.1/6.6
+22-S21
13
14
+59-X6:1L-/18.3+59-X6:PE/18.3
+59-X3:1L-/17.5
+59-X6
1L+
+59-X6
1L-
+59-X6
129
+59-X5
C9HF
-EIN
/27.
3-E
LEKT
RODE
Option19.4/6.5
-Y51
2
+59-X6
1L-
+59-X6
1L+
-A2
+59-X6
118
+59-X5
B8
-Y21
2
+59-X6
1L-
-A1
br
gn ws
Option19.1/6.3
-K211
12 14
+19-K2:14/32.6
-K2A1
A2-K1
A1
A2
B1 A3 B3
+60-X50
C8
+60-X50 C9
+60-MASCHINE X50_C9
X50_C8
-K1
16 18
15
/38.2
/45.2
.4
1112
14.216
18 .215
.4
/12.7/34.5
open jumper at
ignition booster
ws br
electrode gn
beam tube ventilation
setting0,25h
power supplyalignment laser diode
alignment laser diode
on
mode G
TRUMPF
gepr.Name
533FEATH08000327-FEATH
19LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:resonator
= system + site
Drawing Number:
97073-5-202
page
from page9531
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
+59-X6
108
-S31
2
+59-X6
1L+
+59-X6:1L+/18.2+59-X6:1L-/18.3
+59-X6
113
+59-X6
107
-S51
2P
+59-X6
1L+
+59-X6
106
-S61
2P
+59-X6
1L+
+59-X6
102
-S222
21
+59-X6
1L+
+59-X5 A2
+59-X5 A6
+59-X5 A7
+59-X5 B3
+59-X5 A8
+59-
X3:1
6/50
.5
+59-X3
16
1L+
-B3
gnbrws
+59-X6
1L-
+30-XE2
1
+30-XE2
20
+30-XE2
2
+30-XE2
21
+30-XE2
3
+30-BE2
1E-Karte 1
E101.0no
excess temp.at shutter
+30-BE2
2E-Karte 1
E101.2.
+30-BE2
20E-Karte 1
E101.1oil level o.k.
+30-BE2
21E-Karte 1
E101.3.
+30-BE2
3E-Karte 1
E101.4shutterclosed
-B2
br blsw
+59-X6
1103
-S713
14
+59-X6
1L+
1L-
+59-X6
103
+59-X5 A3
+59-
X3:1
7/50
.6
+59-X3
17
Option19.1/6.3
-S81
2P
+59-X6
1L+
+59-X6
122
+59-X5 C2
+30-XE2
22
+30-XE2
26
+30-BE2
22E-Karte 1
E101.5shutteropen
+30-BE2
26E-Karte 1
E102.4air
pressureshutterpresent
+19-
K2:1
4/31
.2
/25.2
/45.2 /45.2/45.2 /45.2 /45.2 /45.2 /45.2
open jumper at
cooling waterflow sensor
Al
cooling waterflow sensor
Cu
notavailable
cooling waterflow sensor
Al
Silicon mirrorblack / silvercooling insert
Copper mirrorred cooling insert
(TLF 1500..3800)
(TLF 3800)
MD 1 = 44000
MD 1 = 44001
TRUMPF
gepr.Name
533FEATH08000327-FEATH
19LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:resonator
= system + site
Drawing Number:
97073-5-202
page
from page9532
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
4 2-X1.1 3 1
-B1
3 1 4 2
+30-XANEA
15 14 13
9 3 2 1 5
+30-BAE1
15 14 13Prozess I/O
actual valuelaser power
ANE1
-N3
9 1 8 4
3 7
.
-X1
Geh.
Option19.5/6.6
+59-X3:L10/19.5+59-X3:L0/19.4
+59-X3:6L-/17.8+59-X3:6L+/17.7
Geh.
/44.2
+
-
laser poweractual value
- +
-+
DC-isolation amplifier
Output 0-10Vmax. 20mAmax.500ø
TRUMPF
gepr.Name
533FEATH08000327-FEATH
19LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:resonator
= system + site
Drawing Number:
97073-5-202
page
from page9533
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
-K113
14
+29-S1
11
12+29-S1
21
22
19 16 17
+29-X1.1 18
+29-X1
18 19 16 17
+60-MASCHINE
X50_B1
X50_B2
X50_B3
X50_B4
X50_C6
X50_C7
=TASC200+30-A6
X6_2 X6_5 X6_6X6_1
+59-X3
26+60
-X50
B1 B2 B3 B4 C6 C7
+59-X3:5L+/17.4
+59-X3:1L-/17.5
-K1A1
A2
+59-X3
27
Option22.1/6.6
-S20
13
14
.3
1 2
3 4/15.5/15.5/15.5.5
5 6
13 14
.7 .6/37.7
/31.4/35.4
emergency stopCPU
emergency stopTASC-Terminal
emergency stop CPU
open jumper at
TRUMPF
gepr.Name
533FEATH08000327-FEATH
22LTLF 1500..3800 turbo
CPU-emergency stop
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:safety circuit
= system + site
Drawing Number:
97073-5-202
page
from page9534
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
-V1
1
2
-K311
14
+59-
X5:A
5/36
.1 +10-K1
31
32
+59-X3:4L+/17.3
+59-X3:1L-/17.5
-K2L+
L-
X1 X2 X4 X3 X5
X6
+10-K2
31
32
+10-K3
31
32
+10-K4
31
32
+10-K5
31
32
-V9
1
2
-V10
1
2
+60-MASCHINE
X50_C3
X50_C4
X50_D1
X50_D2
+60-X50
C3 D1
-K32
4
+30-BA2
27
A-Karte 1
A103.3
checkH.V.contactorsde-energized
+30-XA2
27
D4
+60-X50
D3
+60-MASCHINE
X50_D3 X50_D4
X50:D1/37.1
+10-K4
41
42
+10-K3
41
42
+60-X50 C4 D2
+59-X3
28 +59-X3
29
.6
1112
14.2
/25.6
23 24
33 34
43 44
65 66
53 54
13 14 /25.2/38.6
/25.7
/25.5
/25.5
/25.5
/25.5
/26.2
/45.2
/34.5.7
.4/37.2
safety circuitlaser
H.V.contactorsde-energizedRF generator
emergency stopmachine
LED off= o.k.
LED on= o.k.
LED on= o.k.
open jumper at OEM - laser
TRUMPF
gepr.Name
533FEATH08000327-FEATH
22LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:safety circuit
= system + site
Drawing Number:
97073-5-202
page
from page9535
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
+59-X5:A5/35.2
+59-X3:1L-/17.5
+59-X5
A5
+59-X6
105
-V2
1
2
-S122
21
+59-X5
B1
+59-X6
111
-V3
1
2
+10-X1:20/27.6
+10-
X1:7
/27.
6
-V4
1
2
X50:C3/37.1
/38.7
resonator coverclosed
sum error anddoor switch
RF generator 1
LED on= o.k.
LED on= o.k.
LED on= o.k.
TRUMPF
gepr.Name
533FEATH08000327-FEATH
22LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:safety circuit
= system + site
Drawing Number:
97073-5-202
page
from page9536
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
X50:D1/35.5
X50:C3/36.5+59-X3:1L-/17.5
+60-X50
A1
+60-X50
A2
-K571
72
-K623
24
-K723
24
+60-MASCHINE
X50_A1
X50_A2
+29-S1
41
42
+29-X1
20
+29-X1
21
+29-X1
13
+29-S2
21
22
+29-X1
12
+29-X1.1
20
+29-X1.1
21
+29-X1.1
13
+29-X1.1
12
-V5
1
2
-V6
1
2
-V7
1
2
+59-X6
112
+59-X6
114
Option19.3/6.4
+59-X6
1116
-S822
21
+59-X6
1112
+59-X5
B4
+59-X5
B2
-V8
1
2
-S914
13
/40.4
/40.2
/40.3
/39.2/39.2
/35.7/40.4
/34.7/38.4
/38.5
release high voltage( no feed hold )
safety circuit machine
emergency stop keyTASC-Terminal
key switchbeam lock
TASC-Terminal
open jumper at
beam tube checkexternal closed
telescope cover beam tube checkexternal
LED on= o.k.
LED on= o.k.
LED on= o.k.
normal mode
service mode
LED on= o.k.
TRUMPF
gepr.Name
533FEATH08000327-FEATH
22LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:safety circuit
= system + site
Drawing Number:
97073-5-202
page
from page9537
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
+30-BA2
13
A-Karte 1
A102.3
block shutter(closed)
-K4A1
A2
+30-XA2
13
+59-X3:1L-/17.5
+30-BE2
17E-Karte 1
E104.5key switchbeam off
+30-XE2
17
+29-S2
13
14
+29-X1
25
+29-X1
24
+29-X1.1 25
+29-X1.1
24
+59-X6
117
+59-X6
1L+
+30-XE2
4
+30-BE2
4E-Karte 1
E101.6resonatorhousingopen
+59-X5 B7
+30-BE2
35E-Karte 1
E104.4safetycircuitclosed
+30-XE2
35
-K223
24
+30-BE2
33E-Karte 1
E104.0no
emergency-stopswitch
control panel
+30-XE2
33
+29-S1
31
32
+29-X1
15
+29-X1
14
+29-X1.1 15
+29-X1.1
14
+59-X3:5L+/17.4+59-X6:1L+/18.2
-S113
14/45.2
13 14
23 24/25.2
/25.2/25.4/31.7
33 34
43 44
51 52
61 62
71
81 82
72
/45.2 /45.2/45.2/45.2
/35.2
/36.2
/37.6
/37.7
TRUMPF
gepr.Name
533FEATH08000327-FEATH
22LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:safety circuit
= system + site
Drawing Number:
97073-5-202
page
from page9538
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
+59-X6:1L+/18.2
+59-X6
115
+30-XE2
8
+59-X6
1L+
-S814
13
+59-X6
1L+
+59-X5 B5
+30-BE2
8E-Karte 1
E102.5beam guideway
open
Option19.3/6.4
-S922
21/37.3
/45.2
/37.4
TRUMPF
gepr.Name
533FEATH08000327-FEATH
22LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:safety circuit
= system + site
Drawing Number:
97073-5-202
page
from page9539
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
-K561
62
-K671
72
-K771
72
+29-X1
10
+29-X1.1 10
+29-S3
21
22
1111
+60-MASCHINE
X50_A5
X50_A6
X50_B5
X50_B6
+60-X50
A5 A6 B5 B6
-K6A1
A2
-K513
14-K6
13
14
+29-X1
23
+29-X1.1 23+29-S3
13
14
+29-X1.1
22
+29-X1
22
+59-X3:1L-/17.5
+59-X3:2L+/17.2
-K7A1
A2
-K523
24-K7
13
14
-K5A1
A2
-K751
52-K6
61
62-K7
61
62
-K651
52-K5
33
34
+60-MASCHINE
X50_C1
X50_C2
+60-X50
C1
+60-X50 C2
+30-BE2
15E-Karte 1
E104.1key switch
in service modelaser
-K643
44
-K743
44
+30-XE2
15
+59-X3:5L+/17.4
.4
.4 .4
13 14
23 24.2.3.4
/25.3.8/37.2/25.4
33 34
43 44
51 52
61 62
71
81 82
72
.4
.2
13 14
23 24.2/37.2/25.3.6.4.4.8/25.4
33 34
43 44
51 52
61 62
71
81 82
72
.2
.2
.2
.2
.3
13 14
23 24.3/37.2/25.3.6.4.5.8/25.4
33 34
43 44
51 52
61 62
71
81 82
72
.3
.3 .3
.3
/45.2
.2
.4/41.6
.7
/37.2.7
key switchservice mode
laserservice mode
laserservice mode
TRUMPF
gepr.Name
533FEATH08000327-FEATH
22LTLF 1500..3800 turbo
service mode
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:laser
= system + site
Drawing Number:
97073-5-202
page
from page9540
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
+59-X3:1L-/17.5
+59-X3:4L+/17.3+59-X3:L10/19.5
-K113
14
-K2A1
A2
B1 B2 B3 CI >-K1
A1
A2
+10-K3
23
24+10-K4
23
24
+59-X3
1+59-X3
1
+59-X3:1L-/17.5+59-X6:1L-/18.3+59-X3:1L-/17.5
+59-X6
121
-H2X1
X2-H1
X1
X2
+59-X5
C1
Option23.2/6.8
+59-X3
1
+60-MASCHINE X50_A8
X50_A7 X50_B7 X50_B8
-K123
24
+60-X50 A8
+60-X50
A7 B7 B8
Option23.1/6.7
+30-BE2
16E-Karte 1
E104.3laser
warning lampok
+30-XE2
16
-K215
18
+59-X3:L0/19.4
Option23.1/6.7
Option23.2/6.8
.2
13 14
23 24.4.7
33 34
43 44
.2
1516
18.8
2526
28
.4
/25.5 /25.5
/45.2
/40.7/43.7
laserwarning lamp
ok
laser warning lampresonator
laser warning lampswitch cabinet
laser warning lampmachine
24V DC 10W
laser warning lampmachine
laser warning lampon
1 lamp 0,24A2 lamp 0,48A3 lamp 0,72A(24V DC; 7W / lamp )
Always set total lamp currentas lamp currentto be monitored.
hysteresis 12%
TRUMPF
gepr.Name
533FEATH08000327-FEATH
23LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:laser warning lamp
= system + site
Drawing Number:
97073-5-202
page
from page9541
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
+30-A5
+30-X4
1 2 3 4 5 6 7 8 20
-X2
3 2 7 8 6 5 1 4 Geh.
+59-X3
15 +59-X3
14
-X1
1 2 4 5 63 Geh.
-Z1
-F1
1
23A
+59-X3:1L-/17.5
7L+/15.7+59-X3:PE/17.6
-X2.1
2 3 8 7 4 5 1 6
-X1.1
1 2 3 4 5 6 Geh.
-A1
/66.6
GND TXD RXD RTS CTS DSR GND DCD DTR
LINE
LOAD
RXD TXD CTS RTS DTR GND DSR
24V DC 24V DC 24V DC GND GND GND
InterfaceV24 (COM 2) TASC-Terminalpower supply TASC-Terminal
+29-W2
+29-W1
shield bus shield bus
mains filter( radio interference suppression filter )
TRUMPF
gepr.Name
533FEATH08000327-FEATH
29LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:connection TASC-Terminal
= system + site
Drawing Number:
97073-5-202
page
from page9542
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
-A8
X3_DATA+
X3_DATA-
X3_S
CHIR
M
HF-1LWLS/27.
7BB1LWLS/27.7
+60-MASCHINE
-A1
L1 N PE 1 2
24V
+59-X3:1L-/17.5+59-X3:5L+/17.4+59-X3:PE/17.6
-A7
X3_DATA+
X3_DATA-
X3_S
CHIR
M
-A6
Option60.3/7.6
-F1
1
23A
L20/19.6+59-X3:L0/19.4
-Z1
/66.6
/41.6/49.1
/66.7
/66.4/66.6
SE
grbl
SE
grbl
S E
gr bl
M
L¸fter
power supply TASC 200
fibre-optic cablebit-bus module Interface
mains filter( radio interference suppression filter )
LINE
TRUMPF
gepr.Name
533FEATH08000327-FEATH
30LTLF 1500..3800 turbo
connection bit-bus module
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:connection TASC-200
= system + site
Drawing Number:
97073-5-202
page
from page9543
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
-BAE1 +24V GND PE
12
ANG
19
GND
6 5 4 3 2 1 37 36 35 34 33 3218 17 16 15 14 13 12 11 10 9 8 7ANE0 ANE1 ANE2 ANE3 ANE4 ANE5 ANE6 ANE7
4 13 5 14 6 15 7DigA100.0 DigA100.1 DigA100.2 DigA100.3
3 11 10 2 9 1DigE100.0 DigE100.1 DigE100.2 DigE100.3 DigE100.4 DigE100.5
+ - Schi
rm
+ - Schi
rm
+ - Schi
rm
+ - Schi
rm
+ - Schi
rm
+ - Schi
rm
+ - Schi
rm
+ - Schi
rm
A100
.0
DGND
.0
A100
.1
DGND
.1
A100
.2
DGND
.2
A100
.3
DGND
.3
E100
.0
E100
.1
E100
.2
E100
.3
E100
.4
E100
.5
S
S
S
S
U601
U602
U603
U604
31 30 29 28 27 26 25 24 23 22 21 20ANA0 ANA1 ANA2 ANA3
+ - Schi
rm
+ - Schi
rm
+ - Schi
rm
+ - Schi
rm
Prozess I/ODigital/Analog
GNDX5
X3
X2
X2
GND
X2
U601/27.7
-XDEA12
-XANEAGeh.
-XDEAGeh.
+59-X3:PE/17.6+59-X3:1L-/17.5+59-X3:5L+/17.4
PE/9.8
-XANEA19
+59-X3
1L-+59-X3
PE
/27.2
/28.5 /33.3 /51.2 /51.3
/27.3
/51.3 /51.4
2,5qmm ws wird bei neuerProzess I/O verdrahtet
-A2
not required forneuer Prozess-I/O
TRUMPF
gepr.Name
533FEATH08000327-FEATH
30LTLF 1500..3800 turbo
connection I/O card
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:connection Prozess I/O
= system + site
Drawing Number:
97073-5-202
page
from page9544
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
+59-X3:1L-/17.5+59-X3:1L+/17.1
-BA2
+24V +24V GND GND
A-Karte 1
19 37 18 36 17 35 16 34 15 33 14 32 13 31 12 30 11 29 10 28 9 27 8 26 7 25 6 24 5 23 4 22 3 21 2
A101.0
A101.1
A101.2
A101.3
A101.4
A101.5
A101.6
A101.7
A102.0
A102.1
A102.2
A102.3
A102.4
A102.5
A102.6
A102.7
A103.0
A103.1
A103.2
A103.3
A103.4
A103.5
A103.6
A103.7
A104.0
A104.1
A104.2
A104.3
A104.4
A104.5
A104.6
A104.7
-BE25 28 14 37
E-Karte 1
1 20 2 21 3 22 4 23GND
24 6 25 7 26 8 27 9GND
10 29 11 30 12 31 13 32GND
33 15 34 16 35 17 36 18GND
E101.0
E101.1
E101.2
E101.3
E101.4
E101.5
E101.6
E101.7
E102.0
E102.1
E102.2
E102.3
E102.4
E102.5
E102.6
E102.7
E103.0
E103.1
E103.2
E103.3
E103.4
E103.5
E103.6
E103.7
E104.0
E104.1
E104.2
E104.3
E104.4
E104.5
E104.6
E104.7
-XE2
5
-XE2
28
-XE2
14
-XE2
37
-A3
+59-X3
1L++59-X3
1L-
+59-X3
1L-
+59-X3
1L- +59-X3
1L- +59-X3
1L-
-XE2
Geh.
-XA2
Geh.
/29.
3/2
9.4
/29.
5/2
9.6
/29.
7/3
1.7
/29.
8
/21.
7/2
8.3
/48.
2/3
8.2
/26.
3/2
5.6
/25.
7/2
1.8
/35.
6
/50.
2/5
0.3
/50.
4/5
0.4
/27.
4
/32.
2/3
2.3
/32.
3/3
2.4
/32.
5/3
2.6
/38.
7
/30.
2/3
0.3
/30.
4/3
0.5
/32.
8/3
9.2
/22.
7/2
6.7
/26.
8
/21.
6
/21.
5
/48.
4
/38.
4/4
0.6
/25.
8/4
1.8
/38.
6/3
8.5
/51.
5/5
1.6
/66.6 32-BIT E/A-Karte
TRUMPF
gepr.Name
533FEATH08000327-FEATH
30LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:connection I/O card 1
= system + site
Drawing Number:
97073-5-202
page
from page9545
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8+59-X3:5L+/17.4+59-X3:1L-/17.5
-XE3
37
-BE35 28 14 37
E-Karte 2
1 20 2 21 3 22 4 23GND
24 6 25 7 26 8 27 9GND
10 29 11 30 12 31 13 32GND
33 15 34 16 35 17 36 18GND
E105.0
E105.1
E105.2
E105.3
E105.4
E105.5
E105.6
E105.7
E106.0
E106.1
E106.2
E106.3
E106.4
E106.5
E106.6
E106.7
E107.0
E107.1
E107.2
E107.3
E107.4
E107.5
E107.6
E107.7
E108.0
E108.1
E108.2
E108.3
E108.4
E108.5
E108.6
E108.7
-XE3
5
-XE3
28
-XE3
14
-BA3
+24V +24V GND GND
A-Karte 2
19 37 18 36 17 35 16 34 15 33 14 32 13 31 12 30 11 29 10 28 9 27 8 26 7 25 6 24 5 23 4 22 3 21 2
A105.0
A105.1
A105.2
A105.3
A105.4
A105.5
A105.6
A105.7
A106.0
A106.1
A106.2
A106.3
A106.4
A106.5
A106.6
A106.7
A107.0
A107.1
A107.2
A107.3
A107.4
A107.5
A107.6
A107.7
A108.0
A108.1
A108.2
A108.3
A108.4
A108.5
A108.6
A108.7
-A4
Option60.2/7.5
+59-X3
1L- +59-X3
1L- +59-X3
1L-
+59-X3
5L++59-X3
1L-
+59-X3
1L-
-XE3
Geh.
-XA3
Geh.
/53.
2/5
3.3
/53.
3/5
3.4
/53.
5/5
3.6
/53.
7/5
3.8
/54.
2/5
4.3
/54.
3/5
4.4
/54.
5/5
4.6
/54.
7/5
4.8
/55.
2/5
5.3
/55.
3/5
5.4
/55.
5/5
5.6
/55.
7/5
5.8
/52.
2/5
2.3
/66.632-BIT E/A-Karte
TRUMPF
gepr.Name
533FEATH08000327-FEATH
30LTLF 1500..3800 turbo
Interface DIGITAL
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:connection I/O card 2
= system + site
Drawing Number:
97073-5-202
page
from page9546
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
1L1/9.81L2/9.81L3/9.8PE/9.8
+59-X1
13 14 15 PE
-Q1
1
2
3
4
5
6*
Option47.2/7.2
Option47.1/7.1
Option47.3/7.2
-A1
L1 L2 L3 PE
/48.3
**
connectionchiller Cu/Alspecial chiller400V / 460V
special chiller
chiller
centralcooling system
50 A
*
25 A
10 qmm
**
6 qmm
connection chillernot required for tank heatingand continuouspump operation
Supply directly from themains via separate main switch.
TRUMPF
gepr.Name
533FEATH08000327-FEATH
47LTLF 1500..3800 turbo
power connection
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:LASER cooling
= system + site
Drawing Number:
97073-5-202
page
from page9547
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
-K113
14
-A1
Start 25V_DC
kein_FehlerGND
PE
-X1
4
-X1
6
-X1
3
-X1
5
+30-XE2
32
+59-X3:1L-/17.5
+59-X3:4L+/17.3
+59-X3:1L+/17.1
+30-BE2
32E-Karte 1
E103.7no fault
LASER cooling
+59-X5
C3
-K123
24
+19-Y6
1
2+19-Y7
1
2
+59-X6
1L-
+59-X6
1L-
+59-X6:1L-/18.3
Option47.3/7.2
Option47.3/7.2
+59-X6
123
+59-X6
123
-X1
PE
+59-X3:PE/17.6
Option47.1/7.1
Option47.2/7.2
+30-BA2
32
A-Karte 1
A102.2
LASER coolingon
+30-XA2
32
-K1A1
A2
Option47.3/7.2
.2 .2
13 14
23 24.3.6
33 34
43 44
/45.2
/45.2
/47.2
jumper only for
LASER cooling on
centralcooling system
Al - circuit Cu - circuit
TRUMPF
gepr.Name
533FEATH08000327-FEATH
47LTLF 1500..3800 turbo
control
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:LASER cooling
= system + site
Drawing Number:
97073-5-202
page
from page9548
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
PE/9.8
1L1/9.81L2/9.81L3/9.8
-X41.2 1 2 3 PE
-X3
1 2 3 PE
0L11/10.70L12/10.70L13/10.7
+59-X3:1L+/17.1
-X50
A9 A10
B9
+59-X3:5L+/17.4+59-X3:1L-/17.5
PEB10
+59-X3:PE/17.6
-Q1
1
2
3
4
5
663A
Option60.1/7.4
Option1.4/5.3
-MASCHINE
L1 L2 L3 PE
X50_A9
X50_A10
X50_B9
X50_B10
0L11
0L12
0L13 PE PE
Option1.5/5.4
/43.7/50.1
16qmm
2,5qmmorg IECyel JIC
potential distribution terminal block +60-X50Interface safety
connection machinerated voltage 400V / 460V
connection machinerated voltage 400V / 460V
before main switch
not required for
TRUMPF
gepr.Name
533FEATH08000327-FEATH
60LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:power supply machine
400V / 460V
= system + site
Drawing Number:
97073-5-202
page
from page9549
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
-X55
14
-X55
3
-X55
15
+59-X3:16/32.5
+59-X3:17/32.7
-X55
2
-X55
1
-X55
17
-X55
25
-MASCHINE
X55_14
X55_3
X55_15
X55_25
X55_2
X55_1
X55_17
+30-BA2
24
A-Karte 1
A104.0
laserready
+30-BA2
5
A-Karte 1
A104.1
laser line voltageon
+30-BA2
23
A-Karte 1
A104.2
laser beamignited
+30-BA2
4
A-Karte 1
A104.3
cyclefinished
+30-XA2
24
+30-XA2
5
+30-XA2
23
+30-XA2
4
+59-X3:1L-/17.5
/45.2 /45.2 /45.2 /45.2
/49.1/51.1
shutterclosed
shutteropen
TRUMPF
gepr.Name
533FEATH08000327-FEATH
60LTLF 1500..3800 turbo
machine
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:Interface
= system + site
Drawing Number:
97073-5-202
page
from page9550
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
-MASCHINE
X55_22
X55_10
X55_23
X55_
11
X55_19
X55_20
X55_5
X55_4
+30-XANEA
6 5 4 3 2 1
-X55
22 10 23 11
+30-XDEA
319
1120 5 4
+30-BAE1
6 5 4Prozess I/O
analogfrequency selection
ANE4+30
-BAE1
3 2 1Prozess I/O
laser powerset point
ANE5+30
-BAE1
3Prozess I/O
beam onno delay
DigE100.0+30
-BAE1
11Prozess I/O
shutdown rampon
DigE100.1+30
-BE2
36E-Karte 1
E104.6shutteropen
+30-BE2
18E-Karte 1
E104.7M14
beam on
+30-XE2
36
+30-XE2
18
Geh.
/44.2 /44.2 /44.2 /44.2 /45.2 /45.2
/50.1/52.1
TRUMPF
gepr.Name
533FEATH08000327-FEATH
60LTLF 1500..3800 turbo
machine
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:Interface
= system + site
Drawing Number:
97073-5-202
page
from page9551
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
-MASCHINE
X9_A
4
X9_A
5
X9_B10 PE
+30-BA3
19
A-Karte 2
A105.0
laser powero.k.
+30-BA3
37
A-Karte 2
A105.1
laserautomatic mode
+30-XA3
19
+30-XA3
37-X9
A4
-X9A5
Option60.2/7.5
+59-X3:1L-/17.5
-X9
B10
PE+59-X3:PE/17.6
/46.2 /46.2
/51.1/53.1
TRUMPF
gepr.Name
533FEATH08000327-FEATH
60LTLF 1500..3800 turbo
machine
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:Interface
= system + site
Drawing Number:
97073-5-202
page
from page9552
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
-MASCHINE
X9_A
1
X9_A2
X9_A3
X9_A10
X9_B3
X9_C8
X9_C7
X9_A7
+30-BE3
1E-Karte 2
E105.0laser power
control active
+30-BE3
20E-Karte 2
E105.1laser power
controlvia cycles
+30-BE3
2E-Karte 2
E105.2analog
frequency selectionactive
+30-BE3
21E-Karte 2
E105.3transfer signallaser power
+30-BE3
3E-Karte 2
E105.4transfer signalgating frequency
+30-BE3
22E-Karte 2
E105.5transfer signal
cycle NC
+30-BE3
4E-Karte 2
E105.6laser onautomatic
+30-BE3
23E-Karte 2
E105.7NC-ready
-X9
A1
-X9
A2
-X9
A3
-X9
A10
-X9
B3
-X9
C8
-X9
C7
+30-XE3
1
+30-XE3
20
+30-XE3
2
+30-XE3
3
+30-XE3
4
+30-XE3
21
+30-XE3
22
+30-XE3
23
-X9
A7
Option60.2/7.5
/46.2 /46.2 /46.2 /46.2 /46.2 /46.2 /46.2 /46.2
/52.1/54.1
reserve power 25%M49
transfer signalcycle Nr.laser
interfaceMD 42=2( old )
laserinterfaceMD 42=1( new )
TRUMPF
gepr.Name
533FEATH08000327-FEATH
60LTLF 1500..3800 turbo
machine
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:Interface DIGITAL
= system + site
Drawing Number:
97073-5-202
page
from page9553
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
Option60.2/7.5
-MASCHINE
X9_A9
X9_B
1
X9_B2
X9_C10
X9_B4
X9_B5
X9_B6
X9_B7
+30-BE3
24E-Karte 2
E106.0BCD-value
1
+30-BE3
6E-Karte 2
E106.1BCD-value
2
+30-BE3
25E-Karte 2
E106.2BCD-value
4
+30-BE3
7E-Karte 2
E106.3BCD-value
8
+30-BE3
26E-Karte 2
E106.4BCD-value
10
+30-BE3
8E-Karte 2
E106.5BCD-value
20
+30-BE3
27E-Karte 2
E106.6BCD-value
40
+30-BE3
9E-Karte 2
E106.7BCD-value
80
+30-XE3
24
+30-XE3
6
+30-XE3
25+30
-XE3
7
+30-XE3
26
+30-XE3
8
+30-XE3
27
+30-XE3
9
-X9
A9
-X9B1
-X9
B2
-X9
C10
-X9
B4
-X9
B5
-X9
B6
-X9
B7
/46.2 /46.2 /46.2 /46.2 /46.2 /46.2 /46.2 /46.2
/53.1/55.1
laserinterfaceMD 42=2( old )
laserinterfaceMD 42=1( new )
power 100%M46
power 75%M47
power 50%M48
reserve beam onpulsing
BCD 1 BCD 2 BCD 4
pulse duration
pulse duration = tens digit forcycle No.
TRUMPF
gepr.Name
533FEATH08000327-FEATH
60LTLF 1500..3800 turbo
machine
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:Interface DIGITAL
= system + site
Drawing Number:
97073-5-202
page
from page9554
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
Option60.2/7.5
-MASCHINE
X9_B8
X9_B9
X9_C
1
X9_C2
X9_C3
X9_C4
X9_C5
X9_C6
+30-BE3
10E-Karte 2
E107.0BCD-value
100
+30-BE3
29E-Karte 2
E107.1BCD-value
200
+30-BE3
11E-Karte 2
E107.2BCD-value
400
+30-BE3
30E-Karte 2
E107.3BCD-value
800
+30-BE3
12E-Karte 2
E107.4BCD-value
1000
+30-BE3
31E-Karte 2
E107.5BCD-value
2000
+30-BE3
13E-Karte 2
E107.6BCD-value
4000
+30-BE3
32E-Karte 2
E107.7BCD-value
8000
+30-XE3
10
+30-XE3
29
+30-XE3
11+30
-XE3
30
+30-XE3
12
+30-XE3
31
+30-XE3
13
+30-XE3
32
-X9
C6
-X9
C5
-X9
C4
-X9
C3
-X9
C2
-X9
C1
-X9B9
-X9
B8
/46.2 /46.2 /46.2 /46.2 /46.2 /46.2 /46.2 /46.2
/54.1
laserinterfaceMD 42=1( new )
laserinterfaceMD 42=2( old )
pulse duration pulse duration
BCD 8 BCD 10 BCD 1 BCD 2 BCD4 BCD 8 BCD 10 puls datatransfer
pulse duration = tens digit forcycle No.
pulse duration = units digit forcycle No.
TRUMPF
gepr.Name
533FEATH08000327-FEATH
60LTLF 1500..3800 turbo
machine
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:Interface DIGITAL
= system + site
Drawing Number:
97073-5-202
page
from page9555
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8+59-X3:PE/17.6+59-X3:1L+/17.1+59-X3:1L-/17.5
+59-ASI1
5
11223344
5667788
1-81-81-8
2.12.22.32.42.5
4.14.24.34.44.5
6.16.26.36.46.5
8.18.28.38.48.5
1.11.21.31.41.5
3.13.23.33.43.5
5.15.25.35.45.5
7.17.27.37.47.5
8
6
4
21
3
7
5
6 12
1 2 3 4 5 7 8 9 10 11 13 14 15 16 17 1819
352 41
signalsignal+
-PE
slot
distribution
pin slotfeeder linepin
9
71545816143
171321011181
12 (PE)
6 (-)19 (+)
2
24242424
4242424
5
31
- +PE
+59-X11
6
+59-X11
PE
+59-X11
19
/29.1
/29.
1
/29.3
/29.
3
/29.5
/29.
5
/29.7
/29.
7
/29.2
/29.
2
/30.3
/30.
3
/29.2
/29.
2
/29.4
/29.
4
/29.6
/29.
6
/29.8
/29.
8
/30.2
/30.
2
/30.4
/30.
4
/30.5
/30.
5
/29.1 /29.3
/29.5 /29.7
/29.2 /30.3
/30.5
/29.1 /29.2/30.1
TRUMPF
gepr.Name
533FEATH08000327-FEATH
999LTLF 1500..3800 turbo
gas supply
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:actuator sensor interface
= system + site
Drawing Number:
97073-5-202
page
from page9556
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
+10-X1
control interface RF generator
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Geh.16 17 18 19 20 21 22 23 24 25
+10-X2
power interface RF generator
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PE
+10-X4
power supply RF generator( high voltage )
1 2 3 4 PE+10
-X21
power supply RF generator
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PE
+17-X1
power interface vacuum pump
1 2 3 4 5 6 PE
+19-X1
control interfaceactual value laser power
1 2 3 4 5 6 7 8 9 Geh.
+19-FERRIT1 2 windings
+17-X2
power interface fan( vacuum pump )
1 2 3 PE
+17-X4
control interfacepressure transducer ( supply module )
1 2 3 4 5 6 7 8 9 Geh.
+17-FERRIT1 2 windings
+5-X1
power interface turbine
1 2 3 4 5 6 PE
/27.
2
/27.
6
/27.
3/2
7.5
/27.
4/2
7.5
/27.
5/2
7.2
/27.
5
/27.
6
/27.
3
/27.
6
/27.
6
/23.
3/2
3.3
/23.
3/2
3.4
/23.
5/2
3.6
/23.
6/2
4.6
/24.
6/2
4.6
/23.
6/2
3.7
/23.
8/2
3.8
/23.
8
/24.
3/2
4.3
/24.
3
/24.
3
/23.
3/2
3.3
/23.
3/2
3.4
/23.
5/2
3.6
/23.
6/2
4.6
/24.
6/2
4.6
/23.
6/2
3.7
/23.
8/2
3.8
/23.
8
/28.
2/2
8.2
/28.
2
/28.
2
/33.
3/3
3.3
/33.
2
/33.
3
/33.
2
/33.
2/28.
7/2
8.7
/28.
7
/28.
5/2
8.5
/28.
5/2
8.5
/28.
5
/21.
3/2
1.3
/21.
3/2
1.3
/21.
4/2
1.4
/21.
3
TRUMPF
gepr.Name
533FEATH08000327-FEATH
999LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:overview of connectors
= system + site
Drawing Number:
97073-5-202
page
from page9557
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
+30-XA3 1 102 3 5 6 7 8 9 11 124 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Geh.
+29-X1
control interface / power interface TASC terminal
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Geh.16 17 18 19 20 21 22 23 24 25
+29-X2
Interface V24 (COM2) TASC terminal
1 2 3 4 5 6 7 8 9 Geh.
+30-XANEA 1 102 3 5 6 7 8 9 11 124 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Geh.
+30-XDEA 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Geh.
+30-XE2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Geh.
+30-XA2 1 102 3 5 6 7 8 9 11 124 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Geh.
+30-XE3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Geh.
Option60.2/7.5
Option60.2/7.5
/52.
2
/52.
3
/46.
2
/42.
1/4
2.2
/42.
2/4
2.3
/42.
3/4
2.3
/40.
7/4
0.7
/37.
6/3
7.6
/38.
4/3
8.4
/34.
7/3
4.7
/34.
6/3
4.6
/37.
7/3
7.8
/40.
2/4
0.2
/38.
5/3
8.5
/42.
4
/42.
6/4
2.5
/42.
5/4
2.6
/42.
6/4
2.6
/42.
5/4
2.6
/42.
7
/51.
3/5
1.3
/51.
2/5
1.2
/51.
2/5
1.2
/33.
3/3
3.3
/33.
3/2
8.5
/28.
5/2
8.5
/44.
2
/27.
2/2
7.2
/27.
2
/44.
2
/51.
3/2
7.3
/51.
4/4
4.2
/27.
3
/44.
2
/32.
2/3
2.3
/32.
5/3
8.7
/45.
4/3
0.3
/30.
5/3
9.2
/26.
7
/45.
6/4
0.6
/41.
8/3
8.5
/51.
6
/32.
3/3
2.4
/32.
6
/30.
2/3
0.4
/32.
8/2
2.7
/45.
5/2
6.8
/21.
6/2
1.5
/48.
4/3
8.4
/25.
8/3
8.6
/51.
5/4
5.7
/45.
2
/27.
4
/50.
4/5
0.3
/21.
8/2
5.6
/38.
2/2
8.3
/29.
8/2
9.7
/29.
5/2
9.3
/50.
4/5
0.2
/35.
6
/25.
7/2
6.3
/48.
2/2
1.7
/31.
7/2
9.6
/29.
4
/45.
2
/53.
2/5
3.3
/53.
5/5
3.7
/46.
4/5
4.3
/54.
4/5
4.6
/54.
8/5
5.2
/55.
3/5
5.5
/55.
7/4
6.6
/53.
3/5
3.4
/53.
6/5
3.8
/54.
2/5
4.3
/54.
5/5
4.7
/46.
5/5
5.3
/55.
4/5
5.6
/55.
8
/46.
7
/46.
2
TRUMPF
gepr.Name
533FEATH08000327-FEATH
999LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:overview of connectors
= system + site
Drawing Number:
97073-5-202
page
from page9558
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
+60-X55
Interface machine connection standard
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Geh.16 17 18 19 20 21 22 23 24 25
+60-X50
Interface machine connection standard
A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 PE
+59-X5
resonator
A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 PE
+59-FERRIT1
1 winding
+47-X1
control interface LASER cooling
1 2 3 4 5 6 PE
+60-X3
machine connection power circuitry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PE+59-X11
supply module
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 PE
+60-X9
Interface machine connection BCD
A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 PEOption60.2
/7.5
+60b-X3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PE
/50.
6/5
0.5
/50.
3/5
1.6
/51.
5
/51.
2/5
1.3
/50.
2/5
0.4
/50.
7
/51.
3/5
1.4
/51.
2/5
1.2
/50.
4
/51.
6
/37.
2/3
7.3
/40.
7/4
0.7
/41.
6/4
1.6
/49.
7/4
9.7
/34.
5/3
4.5
/34.
6/3
4.6
/40.
8/4
0.8
/41.
7/4
1.7
/49.
7/4
9.7
/40.
4/4
0.4
/35.
5/3
5.5
/34.
7/3
4.7
/31.
4/3
1.4
/35.
5/3
5.5
/35.
7/3
5.7
/49.
8
/32.
5/3
2.6
/36.
2/3
2.4
/32.
3/3
2.2
/18.
2/1
8.2
/36.
3/3
7.3
/32.
3/3
7.4
/39.
2
/38.
7/3
1.2
/18.
3/1
8.3
/41.
5/3
2.8
/48.
6/3
1.7
/25.
2/2
5.2
/31.
6
/18.
3
/48.
3/4
8.3
/48.
4/4
8.4
/48.
4
/49.
4/4
9.4
/49.
4/1
3.3
/13.
3/1
1.7
/11.
7/1
1.3
/11.
3
/49.
4
/30.
3/2
9.7
/29.
4/2
9.3
/56.
3/2
9.2
/29.
6/3
0.2
/30.
5
/30.
4/2
9.8
/29.
1/2
9.5
/29.
2
/56.
4
/56.
3
/53.
2/5
3.3
/53.
3/5
2.2
/52.
3
/53.
7
/54.
2/5
3.4
/54.
3/5
4.3
/53.
5/5
4.5
/54.
6/5
4.7
/54.
8/5
5.2
/55.
3/5
2.8
/55.
3/5
5.4
/55.
5/5
5.6
/55.
7/5
5.8
/53.
8/5
3.6
/54.
4
/52.
8
/9.6
/9.6
/9.7
/12.
7/1
2.7
TRUMPF
gepr.Name
533FEATH08000327-FEATH
999LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:overview of connectors
= system + site
Drawing Number:
97073-5-202
page
from page9559
Id.-Nr.:
922074
29.03.00
L3
b1 a1
a18b18
b1 a1
b30 a30
b24
a24
b1
a1
digitalinputs
digitaloutputs
CPU 80C186
X3
Eprom 64K*16
analog-digitalconverter
K2
K1
L1
L2
arrangement component side L1
L2 L3
= open
= closed
watchdog
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_10LTLF 1500..3800 turbo
card in RF generator
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:layout diagram TCO-HF1
= system + site
Drawing Number:
97073-5-202
page
from page9560
Id.-Nr.:
922074
29.03.00
X1
X2
X1
X2
C1
C2
A5
A6
A7
A8
B7
B8
C3
C4
A1
A2
-+60-X50B1
B2
B3
B4
C7
C6
B5
B6
-+60-X5554
+19-S1 E101.4
+22-K2 +22-K3 +10-K1 +10-K2
A103.3 A102.33 contactor grouplaser service mode+22-K5 +22-K6
+22-K7
2- contactor grouphigh voltage
RF generator on=10-K3, +10-K4
shutter
+22-S1+22-S2+22-S3+22-S4
+19-S2
+19-S1+23-H1
+23-K2
+23-K1
+29-S1
+29-S2
24V DC supply
+12-K1
1L+/2L+ 3L+
1L+
1L+
1L+
system voltage
HF output stage
feedback
HF-Freigabekein VorschubHalt anLaser von Maschine
digital output
emergency stop circuitmachine
laser warning lampmachinefloating
messagekey switch
laser - service
>I
machine RF generator
resonator
TASC200
+29-S32L+
+29-S1
+29-S1
+19-Y1
+10-K5
A101.5
A102.6
A102.5
E104.6
E104.7
ANA 0
A100.1
CPU -watchdog
+22-S1,+22-S2,+22-S3,+22-S4
+22-S6,+22-S7
+29-S1
+22-K6,+22-K7
+19-S1
+23-K2
+22-K2
+29-S2
E101.7
E102.5
E104.0
E104.1
E104.2
E104.3
E104.4
E104.5
+22-S8,+22-S9 E101.6
+22-S6+22-S7+22-S8+22-S9
laserCPU emergency stop
laseremergency-stop
switch
laseremergency-stop
switch
laser not inservice mode
safety circuitmachine
beam on
shutteropen
key switchlaser - service
machine
laser warning lampmachine24V DC 10W
emergency stop andbeam locklaserfrom machine
set point amplitude H.F.
radio frequencyon
laser - control
safetyemergency stop -main contactor
=L+22-K1
safetyemergency stop -main contactor
=L+22-K2
sum errorDoor - limit switch
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_22LTLF 1500..3800 turbo
( schematic diagram )
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:safety circuit
= system + site
Drawing Number:
97073-5-202
page
from page9561
Id.-Nr.:
922074
29.03.00
-+60-X50A9
A10
B9
B10
=L+10-K1 contact relay beam on in automatic mode
=L+10-K3 main contactor high voltage RF generator 1 on=L+10-K4 main contactor high voltage RF generator 1 on=L+10-K5 main contactor bridge starting resistors
=L+10-K2 contact relay beam on in service mode
meaning item designation
=L+22-K1 main contactor monitoring CPU-emergency stop=L+22-K2 emergency stop - relay monitoring safety circuit closed=L+22-K3 Relay for monitoring wether RF generator high volt.contactors have de-energized. ( above feedback =L+22-K2 X1/X4)=L+22-K4 contact relay beam on above TASC terminal bei geschlossener shutter ( shutter in safety circuit )=L+22-K5, =L+22-K6, =L+22-K7 Contactor relay for three-contactor group laser in service mode=L+23-K1 laser warning lamp on=L+23-K2 monitoring laser warning lamp ( sum current measurement )
=L+10-S1 enable switch beam on=L+19-S2 limit switch shutter closed
=L+22-S1, safety switch RF cover
=L+23-H1 laser warning lamp
=L+29-S2 key switch beam lock in TASC terminal=L+29-S3 key switch laser service mode in TASC terminal
=L+29-S1 emergency stop -push button TASC terminal=L+22-S9 Endschalter Strahlrohrabfragung von Extern=L+22-S8 Haubenschalter Teleskopeabdeckungen
potential distributionInterface safety machine
W1
GND
GND
W3
electrical connectionmechanical connectionsystem limits
signal link
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_22LTLF 1500..3800 turbo
( explanation )
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:safety circuit
= system + site
Drawing Number:
97073-5-202
page
from page9562
Id.-Nr.:
922074
29.03.00
X4
A1 B1
Prozessor
DECD
NRZI 2
NRZI 1
Dual-Port-Ram
EpromBNET
BB-elektrisch
LWL-receiver
LWL-transmitter
X
LWL-receiver
LWL-transmitter
LWL-receiver
LWL-transmitter
X: Variationen
bit-bus module open TCO-HF in RF generator
bit-bus module RF generator 1 bit-bus module RF generator 2
LWL-receiver
LWL-transmitter
LWL-receiver
LWL-transmitter
bit-bus module open basisboard
bit-bus module 1 bit-bus module 2Master for RF generator Slave for control machineserial interface
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_30/10LTLF 1500..3800 turbo
bit-bus module
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:layout diagram
= system + site
Drawing Number:
97073-5-202
page
from page9563
Id.-Nr.:
922074
29.03.00
A1 B1
LWL-Empf‰nger
LWL-Sender
X: Variationen
Bit-Bus-Modul auf TCO-HF1 / HF-Generatoren
Dual-Port-Ram
Prozessor PSD312-20
X1
U2
H1
J4J3
J2
X
bit-bus module 1
H1
J4J3
J2
Master f.HF-Generatorbit-bus module 2
H1
J4J3
J2
Slave f.Masch.steuerung
bit-bus module RF generator 1 bit-bus module RF generator 2
H1
J4J3
J2
H1
J4J3
J2
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_30/10LTLF 1500..3800 turbo
Typ 2 (Siemens)
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:bit-bus module
= system + site
Drawing Number:
97073-5-202
page
from page9564
Id.-Nr.:
922074
29.03.00
E-BYTE 101-104 A-BYTE 101-104
A-BYTE 105-108E-BYTE 105-108
E/A BYTE 100 ANALOG E/A
GND +24V
+24VGND
MELCARDInterface V24Interface V24
BDEA1
BANEA1
BE2BE3
-5X4
-5X5
-6X6
1 2 3 4 5 6 7 8
RESET LEDWATCHDOG
U601 U602 U603 U604
+5V
+12V
+15 MAX
-15 MAX
-12V
LED rt
LED gn LED grn
LED red
LWL-receiver
LWL-transmitter
LWL-receiver
LWL-transmitter
+24V
GND
fan - monitoring
12
34
56
slot
BA2 BE2BA3 BE3
24V
GNDPE -2X5
-4X2-3X2
BA3BA2
-1X1
ANALOGGND
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_30LTLF 1500..3800 turbo
TASC 200
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:control layout
= system + site
Drawing Number:
97073-5-202
page
from page9565
Id.-Nr.:
922074
29.03.00
1 2 3 4 5 6 7 8
Option60.2/7.5
Option60.3/7.6bit-bus module 1
RF generator controlbit-bus module 2external laser control ( option )
+30-A5
+30-A1
+30-A2
+30-A6
+30-A7
+30-A8
+30-A3
+30-A4
/42.5
/43.2
/43.5
/43.5 /43.7
/45.2
/46.2+5V
+12V
+15 MAX
-15 MAX
-12V
12
34
56
slot
primary 220V AV
secondary +5V DC/10A
secondary +12V DC/1,5A
secondary -12V DC/1,5A
32 BIT I/O card ( optional for BCD-interface )
32 BIT I/O card ( optional for BCD-interface )
CPU M17 A16 with system software (Melcard)
basisboard
Prozess CPU
Prozess I/O
power supplyunit :
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_30LTLF 1500..3800 turbo
TASC 200
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:control layout
= system + site
Drawing Number:
97073-5-202
page
from page9566
Id.-Nr.:
922074
29.03.00
X1
OUTPUT INPUT
D210 D205 D201 D204 D208 D211 D215 D214
D212 D207 D203 D202 D206 D209 D218 D216
19 21 23 25
242220 26
9 7 5 3 17 15 13 11
1214161846810
BR2 BR3
2
1
28 30
2927
BR5 BR1
BR4
X5/19
10
1
18
4
5
1
8
18
19
1
36
18
19
1
36
C1
LED X2/1 X2/2
F1 F2
BR2 3 - 4
card codeas follows:
BR2 5 - 6
BR2 7 - 8
BR2 9 - 10
BR4 19 - 20
BR4 21 - 22
BR4 23 - 24
BR4 25 - 26
C2R3
39
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_30LTLF 1500..3800 turbo
I/O card 1
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:layout diagram
= system + site
Drawing Number:
97073-5-202
page
from page9567
Id.-Nr.:
922074
29.03.00
X1
OUTPUT INPUT
D210 D205 D201 D204 D208 D211 D215 D214
D212 D207 D203 D202 D206 D209 D218 D216
19 21 23 25
242220 26
9 7 5 3 17 15 13 11
1214161846810
BR2 BR3
2
1
28 30
2927
BR5 BR1
BR4
X5/19
10
1
18
4
5
1
8
18
19
1
36
18
19
1
36
C1
LED X2/1 X2/2
F1 F2
BR2 3 - 4
card codeas follows:
BR2 5 - 6
BR2 7 - 8
BR4 19 - 20
BR4 21 - 22
BR4 23 - 24
BR4 25 - 26
C2R3
39
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_30LTLF 1500..3800 turbo
I/O card 2
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:layout diagram
= system + site
Drawing Number:
97073-5-202
page
from page9568
Id.-Nr.:
922074
29.03.00
Option51
J209-J210
J211-J212
J205-J206
J207-J208
J203-J204
J215-J216
J201-J202
J213-J214
X2X5
X3U604 U603 U602 U601
X6
C701
U701
D110 D106
X1
BR3
1 1
2 2
C714
LB1
17 15 13 11 9 7 5 3 1
24381012141618
J701.4 J701.1
J701.3 J701.2 S1701
D502D503
D504D505
( soldered joint )
BR1
Adressbit
R=220 Ohm R=10 KOhm
BR1 17 - 18BR3 1 - 2J701.3 - J701.2
resistorsR=220 OhmR=10 KOhmand capacitor10nF solder on
card codeas follows:
D2
EPROM
D14
D1
Prozess CPU
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_30LTLF 1500..3800 turbo
Prozess I/O
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:layout diagram
= system + site
Drawing Number:
97073-5-202
page
from page9569
Id.-Nr.:
922074
29.03.00
SMP - bus - plug
card codeas follows:
AMS - bus - plug
Interface X5 Interface X4
WN2
WN1
WK1
WK2
WK3
12345678910111213
WE1
WE2
WE3
WE4
WJ2
WJ1
1
2
3
4
5
6
7
8
9
1
2
3
4
5
WD2
WD1
WC1
WC2
WC3
rackMemorycard
Prozessor
Epromf¸r 80C31
Coprozessor
EEpromEEprom
WE4 3 - WE4 4WE4 5 - WE3 5WE3 1 - WE3 2WE2 1 - WE1 2WE2 2 - WE1 2WE1 2 - WE2 3WE4 1 - WE4 2
WN2 1 - WN1 1WN2 2 - WN2 6WN2 3 - WN1 4WN2 4 - WN2 5WN2 5 - WN1 9WN2 11 - WN2 12WN2 13 - WN1 13WN1 11 - WN1 12
WK1 5 - WK2 5WK1 6 - WK2 6WK1 7 - WK2 7WK1 8 - WK2 8WK1 9 - WK2 9WK2 3 - WK3 6
WC1 2 - WC1 3WC2 1 - WC2 2WC3 2 - WC3 3
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_30LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:layout diagram CPU M17
= system + site
Drawing Number:
97073-5-202
page
from page9570
Id.-Nr.:
922074
29.03.00
SMP - bus - plug
card codeas follows:
AMS - bus - plug
X3
XB8.4
XB8.5
XB8.6
XB8.7
XB8.1
XB8.2
XB8.3
XB8.8
XB7
XB4
XB5
XB9.1
XB9.2
XB9.3
XB9.4
XB9.5
XB9.6
Litium 3V
G1
D12
D7 D15 D3
D1 D1001B1020R6551A1
01B1020R6552A1 01B1020R6553A1
D4 D5
E9E10
E11
E12
E13
E1E2E3E4E5E6E7E8
XB6.1
XB6.2
XB6.3
XB6.4
XB6.5
XB6.6
XB6.7
01B1020R65411
D6
H1
X7
RESET
X68 7 6 5 4 3 2 1
E5 - E11E6 - E12E7 - E9E8 - E10
XB4XB7
XB9.3
XB8.2XB8.3
XB6.1XB6.3
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_30LTLF 1500..3800 turbo
basisboard
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:layout diagram
= system + site
Drawing Number:
97073-5-202
page
from page9571
Id.-Nr.:
922074
29.03.00
3232
3232
32
11
11
1
3232
3232
32
11
11
1
5781717 15
19 17 15
1919
1313
9
0504
0302
01
0504
0302
01
30
32 28 24 20 16 12 8 4
26 22 18 14 10 6
30
32 28 24 20 16 12 8 4
26 22 18 14 10 6
+5V0V 0V
+5V
PEN
L1
+5V0V
+5V0V
ZD
X1 X2D
Z
Following connectionsmust be wiredon the backplane:
04 B2 - 04 A301 B19 - 02 B1902 B19 - 03 B1903 B19 - 05 B7
01 C19 - 02 C1902 C19 - 03 C1903 C19 - 05 B8
03 C15 - 04 C15 03 C17 - 04 C17 04 B9 - 05 B17
AB
CA
BC
AB
CA
BC
AB
C
AB
CA
BC
AB
CA
BC
AB
C
ACF
SMP - bus AMS - bus
23
SMP - bus AMS - bus
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_30LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:layout diagram Back-Plane
= system + site
Drawing Number:
97073-5-202
page
from page9572
Id.-Nr.:
922074
29.03.00
XDEA
XANEA
XA2
XA3XE2
XE3
+59-X1.1
-D1
+29-
X2.1
+17-
X4
+10-X1
+17-X4.1
-S
+10-X1.1
+59-X11+29-
X2
+29-X1.1
+29-
X1
+60-
X55
+59-
X5
+60-
X9
+60-X50
+19-X1
+5-X
1
TASC 200
TASC-Terminal machine
30x0,5
resonator
+19-B1
+59-X6
+19-A1 +19-Y1
+19-Y2
+19-Y3
+19-Y4
+19-S7
+22-S1
+19-S6
+19-S1
+19-S2
+19-S3
+19-S4
+19-S5
+19-B2
TASC200+30
TASC200+30
4x0,25
3x0,75
supply module
+17-B1
+17-S1
+17-S2
+17-S3
+17-S4
+17-S5
+17-S6RF generator 1
25x0
,09
+17-Y1
+17-Y2
+17-Y3
+17-Y4
+17-Y5
+17-Y6
+17-Y7
+17-Y8
+59-ASI 1
switch cabinet
3X0,75qmm +16X0,34qmm
+29-W2
+60-W4
+19-W1
+17-W3
+10-W1
+17-W1
30x0,5
+60-W2
30x0,5
+60-W1
25x0
,09
+29-W1
4x0,25
+19-W2
+59-FERRIT1
2x +19-FERRIT2
2x
+17-FERRIT2
2x
+22-S9
+22-S8
4X2,5 + 2X0,75
+5-W
1
+5-M1
M3~
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_59LTLF 1500..3800 turbo
control cables
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:cable survey diagram
= system + site
Drawing Number:
97073-5-202
page
from page9573
Id.-Nr.:
922074
29.03.00
+5-X
1
+10-
X5.1
+10-
X5
+17-X1
+59-
X1
+10-
X2+1
0-X2
.1
switch cabinetLeistungsteil
4X2,5 + 2X0,75
+5-W
1
4X1,5
+17-W2
+17-M1
M3~
RF generator 1
+5-M1
M3~
HF-Kabel
resonator
+10-W5
supply module
+10-W3
4X10
+10-W2
18x1
,5
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_59LTLF 1500..3800 turbo
supply leads
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:cable survey diagram
= system + site
Drawing Number:
97073-5-202
page
from page9574
Id.-Nr.:
922074
29.03.00
+59-
X1
+47-
X1
+59-
X1
switch cabinetpower circuitry
machine
4X 1
6 qm
m
4X 1
6 qm
m+47-W1
7X1,5
+47-W2
incoming supply
chiller 1
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_59LTLF 1500..3800 turbo
supply leads
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:cable survey diagram
= system + site
Drawing Number:
97073-5-202
page
from page9575
Id.-Nr.:
922074
29.03.00
+59-
X5+59-X3
+5-X
1
+59-X1
+59-X11
+59-
X1
+10-
X2.1
+10-
X2
+59-X2
X20
+59-
X2
+59-
X12
+59-X6
resonator
+5-M1
M3~
housing 6qmm
supply module
+17-M1
M3~
housing
0,5qmm
6qmm
16qmm2,5qmm
25qmm
35qmm
+19-W1
+5-W
1
0,5qmm
+17-W2
PE busbar
6qmm
+17-W1
switch cabinet
+10-W2
+10-W3
1,5qmm
1,5qmm
10qmm
25qmm
1,5qmm
RF generator 1
+59-X11
+59-X12
+17-W4
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_59LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:ground
= system + site
Drawing Number:
97073-5-202
page
from page9576
Id.-Nr.:
922074
29.03.00
+47-
X1
+59-
X1
+59-
X1
16qmm
machine
16 q
mm+47-W1
1,5qmm
+47-W2
PE busbar
chiller 1
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_59LTLF 1500..3800 turboRevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:ground
= system + site
Drawing Number:
97073-5-202
page
from page9577
Id.-Nr.:
922074
29.03.00
+10-K3
+10-K4
+10-K5
PE
+10
-R5 -R6
-R1-R2 -R3
-R4
+10-
X4+1
0-X2
+1-Q1
+5-Q1
+10-Q4
+47-
Q1
+60-Q1
+1-Q
3
+2-Q
1
+1-Q
4
power side
+59-X1
PE
+60-X41.2
1 2 313 14 15
+60-X3
+17-
K1
+5-X1
+17-X1
+1-S9
door catch left
( cl
imat
e do
or +
9-A2
)
TASC 200
+5-K
2
+10-K1
+10-K2
+22-K1
+22-
K2
+59-
X3
+30
-XE2
+30
-XE3
+30
-XA2
+30
-XA3
+30
-XAN
EA+30-A6+30-Z1
+29-Z1
+30
-XDE
A
control side
from leftto right+4-F1+4-F2+4-F4+4-F5+29-F1
+23-K2
+22-K4
+22-K5
+22-K6
+22-K7
+23-
K1
+47-
K1
+4-G1
+1-S10
side view
supply module
+9-A1
+1-S1
+1-S
2+2
2-S2
0+2
2-S2
1
+10-S1
+23-H1
3-phasig 2-phasig
+5-A
2
+5-T1 +5-A1
FU 6A
+5-A
2
+5-A
3 +5-A1
FU 12A
FU 33A
+5-A
2
+5-A1
+10-Q5
+17-Q1
+4-Q
2
+10-Q2
+10-Q3
+9-Q
1
+1-Q
2
+10-Q1
+4-Q
1
2-phasig3-phasig
+4-Q
2
+9-Q
1
+1-Q
2
+17-Q1
+4-Q
1
+10-Q1
+10-Q5
+10-Q2
+10-Q3
3-phasig
for 400V
for 460V
460V
2-phasig 3-phasig 2-phasig
400V
+4-F10+30-F1+4-Q4+1-F1+2-F1
24V AC
230V
+4-F11110V
+59-X2
+2-E1 +2-E2
400V 400V
+4-G
2+19-N3
+1-T1+4-T1
+1-T2
+2-T1
+4-X2
+9-S1
Attach on
system chassis
side
+10-
K7
+10-
K8
+10-
K11
+5-K
1
+10-K13
+1-K1
Opt.
=L+17-X4
=L+1
9-X1
=L+1
0-X1 =L
+60-X50
=L+6
0-X55
24V DC
230V
FI
=L+60-X9
=L+2
9-X2=L+59-X11
=L+2
9-X1
=L+59-X5
+59-FERRIT1
+17-FERRIT1+19-FERRIT1
BondingPoint
ESD
BONDING POINTAttach onsystem chassisside
+4-P
1+4
-X1
+22-K3 +19-K2
+19-K1
door catch right
main switch
not required for
option 1.5
2004.5
802
TRUMPF
gepr.Name
533FEATH08000327-FEATH
INFO_59LTLF 1500..3800 turbo
( maximum extension TLF3800)
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:switch cabinet layout
= system + site
Drawing Number:
97073-5-202
page
from page9578
Id.-Nr.:
922074
29.03.00
--------------------------------------------------------------------------------| P L C L I S T |----------------------------------------------------------------------------------------------------------------------------------------------------------------|Address| Inst. Loc. Dev.ID | Line No. | PLC Text |--------------------------------------------------------------------------------|>| | | | on ||>| | | | system pressure ||>| | | | amplitude H.F. ||>| | | | laser power ||>| | | | frequency selection ||>| | | | set point ||>| | | | on ||>| | | | no delay ||>A101.0| =L+30-BA2:19 | L 29.3 |>gas mix || | | | slow ||>A101.1| =L+30-BA2:37 | L 29.4 |>gas mix || | | | fast ||>A101.2| =L+30-BA2:18 | L 29.5 |>pump out || | | | slow ||>A101.3| =L+30-BA2:36 | L 29.6 |>pump out || | | | fast ||>A101.4| =L+30-BA2:17 | L 29.7 |>pump out || | | | gear chamber fast ||>A101.5| =L+30-BA2:35 | L 31.7 |>shutter || | | | open ||>A101.6| =L+30-BA2:16 | L 29.8 |>vacuum || | | | system || | | | open ||>A101.7| =L+30-BA2 | |> ||>A102.0| =L+30-BA2:33 | L 21.7 |>system voltage || | | | turbine 1 on ||>A102.1| =L+30-BA2:14 | L 28.3 |>vacuum pump on ||>A102.2| =L+30-BA2:32 | L 48.2 |>LASER cooling || | | | on ||>A102.3| =L+30-BA2:13 | L 38.2 |>block shutter || | | | (closed) ||>A102.4| =L+30-BA2:31 | L 26.3 |>filament || | | | a.grid || | | | volt.on ||>A102.5| =L+30-BA2:12 | L 25.6 |>high voltage || | | | on || | | | automatik || | | | mode ||>A102.6| =L+30-BA2:30 | L 25.7 |>high volt.on || | | | service || | | | mode || | | | |-------------------------------------------------------------------------------- continued on page 2
TRUMPF
Name
533FEATHPLC List
000327-FEATH
08 OHNE_ORTIORevision-Number
Promis:
APPR.
Print date:
drawnby
date
Project Title:
Page Title:TLF 1500..3800 turbo
97073-5-202
1
922074
= system + site
Drawing Number: Id.-Nr.:
page
page95from
97073-5-202.8 29.03.00RevisionIndex
--------------------------------------------------------------------------------| P L C L I S T |----------------------------------------------------------------------------------------------------------------------------------------------------------------|Address| Inst. Loc. Dev.ID | Line No. | PLC Text |--------------------------------------------------------------------------------|>A102.7| =L+30-BA2:11 | L 21.8 |>turbine 1 || | | | start ||>A103.0| =L+30-BA2 | |> ||>A103.1| =L+30-BA2 | |> ||>A103.2| =L+30-BA2 | |> ||>A103.3| =L+30-BA2:27 | L 35.6 |>check || | | | H.V.contactors || | | | de-energized ||>A103.4| =L+30-BA2 | |> ||>A103.5| =L+30-BA2 | |> ||>A103.6| =L+30-BA2 | |> ||>A103.7| =L+30-BA2 | |> ||>A104.0| =L+30-BA2:24 | L 50.2 |>laser || | | | ready ||>A104.1| =L+30-BA2:5 | L 50.3 |>laser line voltage || | | | on ||>A104.2| =L+30-BA2:23 | L 50.4 |>laser beam || | | | ignited ||>A104.3| =L+30-BA2:4 | L 50.4 |>cycle || | | | finished ||>A104.4| =L+30-BA2 | |> ||>A104.5| =L+30-BA2 | |> ||>A104.6| =L+30-BA2 | |> ||>A104.7| =L+30-BA2:2 | L 27.4 |>reset || | | | RF generator ||>A105.0| =L+30-BA3:19 | L 52.2 |>laser power || | | | o.k. ||>A105.1| =L+30-BA3:37 | L 52.3 |>laser || | | | automatic mode ||>A105.2| =L+30-BA3 | |> ||>A105.3| =L+30-BA3 | |> ||>A105.4| =L+30-BA3 | |> ||>A105.5| =L+30-BA3 | |> ||>A105.6| =L+30-BA3 | |> ||>A105.7| =L+30-BA3 | |> ||>A106.0| =L+30-BA3 | |> ||>A106.1| =L+30-BA3 | |> ||>A106.2| =L+30-BA3 | |> ||>A106.3| =L+30-BA3 | |> ||>A106.4| =L+30-BA3 | |> ||>A106.5| =L+30-BA3 | |> ||>A106.6| =L+30-BA3 | |> ||>A106.7| =L+30-BA3 | |> ||>A107.0| =L+30-BA3 | |> ||>A107.1| =L+30-BA3 | |> ||>A107.2| =L+30-BA3 | |> ||>A107.3| =L+30-BA3 | |> ||>A107.4| =L+30-BA3 | |> ||>A107.5| =L+30-BA3 | |> ||>A107.6| =L+30-BA3 | |> |-------------------------------------------------------------------------------- continued on page 3
TRUMPF
Name
533FEATHPLC List
000327-FEATH
08 OHNE_ORTIORevision-Number
Promis:
APPR.
Print date:
drawnby
date
Project Title:
Page Title:TLF 1500..3800 turbo
97073-5-202
2
922074
= system + site
Drawing Number: Id.-Nr.:
page
page95from
97073-5-202.8 29.03.00RevisionIndex
--------------------------------------------------------------------------------| P L C L I S T |----------------------------------------------------------------------------------------------------------------------------------------------------------------|Address| Inst. Loc. Dev.ID | Line No. | PLC Text |--------------------------------------------------------------------------------|>A107.7| =L+30-BA3 | |> ||>A108.0| =L+30-BA3 | |> ||>A108.1| =L+30-BA3 | |> ||>A108.2| =L+30-BA3 | |> ||>A108.3| =L+30-BA3 | |> ||>A108.4| =L+30-BA3 | |> ||>A108.5| =L+30-BA3 | |> ||>A108.6| =L+30-BA3 | |> ||>A108.7| =L+30-BA3 | |> ||>E101.0| =L+30-BE2:1 | L 32.2 |>no || | | | excess temp. || | | | at shutter ||>E101.1| =L+30-BE2:20 | L 32.3 |>oil level o.k. ||>E101.2| =L+30-BE2:2 | L 32.3 |>. ||>E101.3| =L+30-BE2:21 | L 32.4 |>. ||>E101.4| =L+30-BE2:3 | L 32.5 |>shutter || | | | closed ||>E101.5| =L+30-BE2:22 | L 32.6 |>shutter || | | | open ||>E101.6| =L+30-BE2:4 | L 38.7 |>resonator || | | | housing || | | | open ||>E101.7| =L+30-BE2 | |> ||>E102.0| =L+30-BE2:24 | L 30.2 |>gas pressure || | | | N2 >4000hPa ||>E102.1| =L+30-BE2:6 | L 30.3 |>gas pressure || | | | CO2 >4000hPa ||>E102.2| =L+30-BE2:25 | L 30.4 |>gas pressure || | | | HE >4000hPa ||>E102.3| =L+30-BE2:7 | L 30.5 |>system || | | | pressure || | | | <1100hPa ||>E102.4| =L+30-BE2:26 | L 32.8 |>air || | | | pressure || | | | shutter || | | | present ||>E102.5| =L+30-BE2:8 | L 39.2 |>beam guideway || | | | open ||>E102.6| =L+30-BE2:27 | L 22.7 |>no excess current || | | | prot.circuit braker || | | | and || | | | no ||>E102.7| =L+30-BE2:9 | L 26.7 |>no || | | | voltage loss || | | | high volt. || | | | RF ||>E103.0| =L+30-BE2 | |> ||>E103.1| =L+30-BE2:29 | L 26.8 |>high voltage on || | | | RF 1 ||>E103.2| =L+30-BE2 | |> |-------------------------------------------------------------------------------- continued on page 4
TRUMPF
Name
533FEATHPLC List
000327-FEATH
08 OHNE_ORTIORevision-Number
Promis:
APPR.
Print date:
drawnby
date
Project Title:
Page Title:TLF 1500..3800 turbo
97073-5-202
3
922074
= system + site
Drawing Number: Id.-Nr.:
page
page95from
97073-5-202.8 29.03.00RevisionIndex
--------------------------------------------------------------------------------| P L C L I S T |----------------------------------------------------------------------------------------------------------------------------------------------------------------|Address| Inst. Loc. Dev.ID | Line No. | PLC Text |--------------------------------------------------------------------------------|>E103.3| =L+30-BE2:30 | L 21.6 |>no frequency || | | | converter fault || | | | turbine 1 ||>E103.4| =L+30-BE2 | |> ||>E103.5| =L+30-BE2:31 | L 21.5 |>nominal frequency || | | | reached || | | | turbine 1 ||>E103.6| =L+30-BE2 | |> ||>E103.7| =L+30-BE2:32 | L 48.4 |>no fault || | | | LASER cooling ||>E104.0| =L+30-BE2:33 | L 38.4 |>no || | | | emergency-stop || | | | switch || | | | control panel ||>E104.1| =L+30-BE2:15 | L 40.6 |>key switch || | | | in service mode || | | | laser ||>E104.2| =L+30-BE2:34 | L 25.8 |>enable || | | | switch || | | | beam on ||>E104.3| =L+30-BE2:16 | L 41.8 |>laser || | | | warning lamp || | | | ok ||>E104.4| =L+30-BE2:35 | L 38.6 |>safety || | | | circuit || | | | closed ||>E104.5| =L+30-BE2:17 | L 38.5 |>key switch || | | | beam off ||>E104.6| =L+30-BE2:36 | L 51.5 |>shutter || | | | open ||>E104.7| =L+30-BE2:18 | L 51.6 |>M14 || | | | beam on ||>E105.0| =L+30-BE3:1 | L 53.2 |>laser power || | | | control active ||>E105.1| =L+30-BE3:20 | L 53.3 |>laser power || | | | control || | | | via cycles ||>E105.2| =L+30-BE3:2 | L 53.3 |>analog || | | | frequency selection || | | | active ||>E105.3| =L+30-BE3:21 | L 53.4 |>transfer signal || | | | laser power ||>E105.4| =L+30-BE3:3 | L 53.5 |>transfer signal || | | | gating frequency ||>E105.5| =L+30-BE3:22 | L 53.6 |>transfer signal || | | | cycle NC ||>E105.6| =L+30-BE3:4 | L 53.7 |>laser on || | | | automatic ||>E105.7| =L+30-BE3:23 | L 53.8 |>NC-ready || | | | |-------------------------------------------------------------------------------- continued on page 5
TRUMPF
Name
533FEATHPLC List
000327-FEATH
08 OHNE_ORTIORevision-Number
Promis:
APPR.
Print date:
drawnby
date
Project Title:
Page Title:TLF 1500..3800 turbo
97073-5-202
4
922074
= system + site
Drawing Number: Id.-Nr.:
page
page95from
97073-5-202.8 29.03.00RevisionIndex
--------------------------------------------------------------------------------| P L C L I S T |----------------------------------------------------------------------------------------------------------------------------------------------------------------|Address| Inst. Loc. Dev.ID | Line No. | PLC Text |--------------------------------------------------------------------------------|>E106.0| =L+30-BE3:24 | L 54.2 |>BCD-value || | | | 1 ||>E106.1| =L+30-BE3:6 | L 54.3 |>BCD-value || | | | 2 ||>E106.2| =L+30-BE3:25 | L 54.3 |>BCD-value || | | | 4 ||>E106.3| =L+30-BE3:7 | L 54.4 |>BCD-value || | | | 8 ||>E106.4| =L+30-BE3:26 | L 54.5 |>BCD-value || | | | 10 ||>E106.5| =L+30-BE3:8 | L 54.6 |>BCD-value || | | | 20 ||>E106.6| =L+30-BE3:27 | L 54.7 |>BCD-value || | | | 40 ||>E106.7| =L+30-BE3:9 | L 54.8 |>BCD-value || | | | 80 ||>E107.0| =L+30-BE3:10 | L 55.2 |>BCD-value || | | | 100 ||>E107.1| =L+30-BE3:29 | L 55.3 |>BCD-value || | | | 200 ||>E107.2| =L+30-BE3:11 | L 55.3 |>BCD-value || | | | 400 ||>E107.3| =L+30-BE3:30 | L 55.4 |>BCD-value || | | | 800 ||>E107.4| =L+30-BE3:12 | L 55.5 |>BCD-value || | | | 1000 ||>E107.5| =L+30-BE3:31 | L 55.6 |>BCD-value || | | | 2000 ||>E107.6| =L+30-BE3:13 | L 55.7 |>BCD-value || | | | 4000 ||>E107.7| =L+30-BE3:32 | L 55.8 |>BCD-value || | | | 8000 ||>E108.0| =L+30-BE3 | |> ||>E108.1| =L+30-BE3 | |> ||>E108.2| =L+30-BE3 | |> ||>E108.3| =L+30-BE3 | |> ||>E108.4| =L+30-BE3 | |> ||>E108.5| =L+30-BE3 | |> ||>E108.6| =L+30-BE3 | |> ||>E108.7| =L+30-BE3 | |> || | | | || | | | || | | | || | | | || | | | || | | | || | | | || | | | || | | | || | | | |-------------------------------------------------------------------------------- end of list
TRUMPF
Name
533FEATHPLC List
000327-FEATH
08 OHNE_ORTIORevision-Number
Promis:
APPR.
Print date:
drawnby
date
Project Title:
Page Title:TLF 1500..3800 turbo
97073-5-202
5
922074
= system + site
Drawing Number: Id.-Nr.:
page
page95from
97073-5-202.8 29.03.00RevisionIndex
wirelabelca
bel
wire
gag
e
from
=Lc.+Dev.-ID:Conn.pt.Page.-line no.
Terminal Stripto
=Lc.+Dev.-ID:Conn.pt.Term.-No.
wirelabel ca
bel
wire
gag
e
jumper
*
Id.-Nr.:
*
=L+59-X1
1347.2+47-Q1:2 +47-A1:L1 1447.2+47-Q1:4 +47-A1:L2 1547.2+47-Q1:6 +47-A1:L3 PE47.3+47-A1:PE +1.-X1:PE
TRUMPF
gepr.Name
533FEATH08000327-FEATH
59KLEMPLANTLF 1500..3800 turbo
KLEMMENPLAN
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:=L+59-X1
= system + site
Drawing Number:
97073-5-202
page
from page951
Id.-Nr.:
922074
29.03.00
wirelabelca
bel
wire
gag
e
from
=Lc.+Dev.-ID:Conn.pt.Page.-line no.
Terminal Stripto
=Lc.+Dev.-ID:Conn.pt.Term.-No.
wirelabel ca
bel
wire
gag
e
jumper
*
Id.-Nr.:
*
=L+59-X2
PE11.1 +1.-X1:PE 0511.1L01411.1+60-X3:8 +1-T1:3 L1411.4+1-S9:13 +60-X3:9
+1-S2:13 111.4+1-S10:13 +1-S9:14 211.4+1-S11:13 +1-S10:14 311.4+1-S12:13 +1-S11:14 411.4+1-K1:A1 +1-S12:14 511.7+60-X3:6 +1-K1:14 611.7+1-S2:14 +60-X3:7 713.5 +1-K1:22 PE13.1 +1.-X1:PE 0613.1L01513.2+60-X3:4 +2-T1:3 L1513.3+60-X3:5 +2-F1:2
+1-K1:21 PE13.5 +1.-X1:PE PE13.7
TRUMPF
gepr.Name
533FEATH08000327-FEATH
59KLEMPLANTLF 1500..3800 turbo
KLEMMENPLAN
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:=L+59-X2
= system + site
Drawing Number:
97073-5-202
page
from page952
Id.-Nr.:
922074
29.03.00
wirelabelca
bel
wire
gag
e
from
=Lc.+Dev.-ID:Conn.pt.Page.-line no.
Terminal Stripto
=Lc.+Dev.-ID:Conn.pt.Term.-No.
wirelabel ca
bel
wire
gag
e
jumper
*
Id.-Nr.:
*
=L+59-X3
L016.2 +4-G2:9 L019.4 +4-Q4:2 L020.2 +4-X1 L022.2 +9-A1:N L028.7 +17-X2:2 0319.2 +4-T1:3 PE19.2 +1.-X1:PE L1016.2 +4-G2:11 L1019.5 +4-F10:2 L1020.2L1022.2 +9-A1:L1 L1028.7 +17-X2:1 1L+17.1-X5:A9 +22-K1:2 1L+45.3+30-BA2:+24V +30-BA2:+24V 2L+17.2+22-K2:13 +22-K1:4 2L+25.8+22-K2:13 +10-S1:bl 4L+17.3+22-K2:L+ +22-K1:6 5L+17.4+59-X3:5L+ +4-F5:2 5L+46.3+30-BA3:+24V +30-BA3:+24V 6L+16.2+4-G2:1 6L+17.7 +17-X4:4
6L- 6L-16.2+4-G2:8 06 6L-16.3 +4-G2:8 6L- 6L-17.8 +19-X1:1 6L- 0616.3
PE16.3 +1.-X1:PE 01 1L-15.1 +4-G1:M
1L-17.5-X5:B9 +4-G1:M 1L-44.2+30-XDEA:12 +30-BAE1:GND 1L-45.21L-45.3+30-BA2:GND +30-BA2:GND 1L-45.4 +30-XE2:5 1L-45.5 +30-XE2:28 1L-45.6+30-XE2:14 +30-XE2:37 1L-46.21L-46.3+30-BA3:GND +30-BA3:GND 1L-46.4 +30-XE3:5 1L-46.5 +30-XE3:28 1L-46.6+30-XE3:14 +30-XE3:37
PE 0115.1
TRUMPF
gepr.Name
533FEATH08000327-FEATH
59KLEMPLANTLF 1500..3800 turbo
KLEMMENPLAN
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:=L+59-X3
= system + site
Drawing Number:
97073-5-202
page
from page953
Id.-Nr.:
922074
29.03.00
wirelabelca
bel
wire
gag
e
from
=Lc.+Dev.-ID:Conn.pt.Page.-line no.
Terminal Stripto
=Lc.+Dev.-ID:Conn.pt.Term.-No.
wirelabel ca
bel
wire
gag
e
jumper
*
Id.-Nr.:
*
=L+59-X3
01 PE15.1 +1.-X1:PE 141.5+23-K2:C +23-H1:X1 141.5 -X5:C1 141.6 +60-X50:A7 1442.3 +29-X1:4 1542.2 +29-X1:3 1632.5-X5:A2 +30-XE2:3
+60-X55:2 1732.6-X5:A3 +30-XE2:22
+60-X55:1 1827.3+30-XDEA:4 +10-X1:9 1927.3+30-XDEA:13 +10-X1:22 2025.2+22-K2:14 +10-S1:ws 2125.2 +10-S1:sw
+10-S1:br 2225.8+30-XE2:34 +10-S1:rt 2325.2+22-K4:51 +10-S1:gr 2634.3 +22-S20:13 2734.3+22-K1:A1 +22-S20:14 2835.5+22-V9:1 +60-X50:C4 2935.5+22-V10:1 +60-X50:D2 PE17.6-X5:PE +1.-X1:PE PE20.2 +4-X1 PE22.2 +9-A1:PE PE25.2PE25.8PE28.7 +17-X2:PE PE44.2+30-XANEA:19 +30-BAE1:PE
TRUMPF
gepr.Name
533FEATH08000327-FEATH
59KLEMPLANTLF 1500..3800 turbo
KLEMMENPLAN
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:=L+59-X3
= system + site
Drawing Number:
97073-5-202
page
from page953.1
Id.-Nr.:
922074
29.03.00
wirelabelca
bel
wire
gag
e
from
=Lc.+Dev.-ID:Conn.pt.Page.-line no.
Terminal Stripto
=Lc.+Dev.-ID:Conn.pt.Term.-No.
wirelabel ca
bel
wire
gag
e
jumper
*
Id.-Nr.:
*
=L+59-X6
PE18.3-X5:PE +19-A1:gn 1L+18.2-X5:A9 1L+31.5 +19-Y5:1 1L+31.61L+32.2 +19-S3:1 1L+32.3 +19-B3:br 1L+32.3 +19-S5:1 1L+32.4 +19-S6:1 1L+32.5 +19-S2:22 1L+32.6 +19-B2:br 1L+32.8 +19-S8:1 1L+38.7 +22-S1:13 1L+39.2 +22-S8:14 1L+39.2 +22-S9:22 1L-18.3-X5:B9 +19-A1:ws 1L-31.3 +19-A1:ws
+19-Y2:2 1L-31.5 +19-Y5:2 1L-31.61L-31.7 +19-Y1:2 1L-32.2 +19-B3:ws 1L-32.6 +19-B2:bl 1L-48.6 +19-Y6:2 1L-48.7 +19-Y7:2 10232.5-X5:A2 +19-S2:21
1103 10332.6-X5:A3 +19-S7:14 10536.2-X5:A5 +22-S1:22 10632.4-X5:A6 +19-S6:2 10732.3-X5:A7 +19-S5:2 10832.2-X5:A8 +19-S3:2 11136.3-X5:B1 +22-S1:21 11237.3-X5:B2 +22-S8:22 11332.3-X5:B3 +19-B3:gn 11437.4-X5:B4 +22-S9:14 11539.2-X5:B5 +22-S9:21
+22-S8:13 11738.7-X5:B7 +22-S1:14 11831.2-X5:B8 +19-A1:br
+19-Y2:1 12141.5-X5:C1 +23-H2:X1
TRUMPF
gepr.Name
533FEATH08000327-FEATH
59KLEMPLANTLF 1500..3800 turbo
KLEMMENPLAN
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:=L+59-X6
= system + site
Drawing Number:
97073-5-202
page
from page954
Id.-Nr.:
922074
29.03.00
wirelabelca
bel
wire
gag
e
from
=Lc.+Dev.-ID:Conn.pt.Page.-line no.
Terminal Stripto
=Lc.+Dev.-ID:Conn.pt.Term.-No.
wirelabel ca
bel
wire
gag
e
jumper
*
Id.-Nr.:
*
=L+59-X6
12232.8-X5:C2 +19-S8:2 12348.6-X5:C3 +19-Y6:1 12348.7-X5:C3 +19-Y7:1 12431.7-X5:C4 +19-Y1:1 12725.2-X5:C7 +19-S2:12 12825.2-X5:C8 +19-S2:11 12931.6-X5:C9
103 110332.6+19-S7:13 +19-B2:sw 111237.3 +22-S8:21
114 111637.4 +22-S9:13
TRUMPF
gepr.Name
533FEATH08000327-FEATH
59KLEMPLANTLF 1500..3800 turbo
KLEMMENPLAN
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:=L+59-X6
= system + site
Drawing Number:
97073-5-202
page
from page954.1
Id.-Nr.:
922074
29.03.00
wirelabelca
bel
wire
gag
e
from
=Lc.+Dev.-ID:Conn.pt.Page.-line no.
Terminal Stripto
=Lc.+Dev.-ID:Conn.pt.Term.-No.
wirelabel ca
bel
wire
gag
e
jumper
*
Id.-Nr.:
*
=L+60-X41.2
149.2-Q1:2 -MASCHINE:L1 249.2-Q1:4 -MASCHINE:L2 349.2-Q1:6 -MASCHINE:L3 PE49.2-MASCHINE:PE +1.-X1:PE
TRUMPF
gepr.Name
533FEATH08000327-FEATH
60KLEMPLANTLF 1500..3800 turbo
KLEMMENPLAN
RevisionIndexRevision-Number
Promis: 97073-5-202.8 Print date:drawnby
date
Project Title:
Page Title:=L+60-X41.2
= system + site
Drawing Number:
97073-5-202
page
from page955
Id.-Nr.:
922074
29.03.00
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant938987 SWITCH CABINET 97073-509
komplett; TLF 1500T.4000T10 1 ST 938988 SWITCH CABINET 97073-509-10 DISPOLISTE TLF1800-4000T
100 1 ST 920298 SWITCH CABINET 97073-513 MIT KLIMATÜR110 1 ST 922809 SWITCH CABINET 97073-514 MIT WÄRMETAUSCHER111 1 ST 955426 ELECTRIC EQUIPMENT 97073-519 ESD ALLGEMEIN
BEI: BEDIENPULT IM TUERAUSSCHNITT140 1 ST 900483 CABINET 9707-241 ALLE MASCHINEN AUSSER TC L2530
SCHRANK VERSORGUNGSEINHEIT KOMPLETT145 1 ST 933526 CABINET S98527-190150 1 ST 920733 HOSE 9707-700
STANDARD160 1 ST 920734 HOSE 9707-701
BEI: TROPEN170 1 ST 942938 HOSE 9707-702 VERSORGUNGSSCHRANK180 1 ST 942939 HOSE 9707-703 VERSORGUNGSSCHRANK190 1 ST 922860 SWITCH CABINET 97073-512200 1 ST 922862 ELECTRIC EQUIPMENT 97073-521 EINSPEISUNG 400V
BEI: NETZSPANNUNG 400V 50HZ201 1 ST 955579 ELECTRIC EQUIPMENT 97073-589 EINSPEISUNG 400V OHNE HAUPTSCHALTER
BEI: NETZSPANNUNG 400V 50HZ210 1 ST 922863 ELECTRIC EQUIPMENT 97073-522 EINSPEISUNG 460V
BEI: NETZSPANNUNG 460V 60HZ211 1 ST 955580 ELECTRIC EQUIPMENT 97073-590 EINSPEISUNG 460V OHNE HAUPTSCHALTER
BEI: NETZSPANNUNG 400V 50HZ220 1 ST 922861 ELECTRIC EQUIPMENT 97073-523 NETZSPANNUNG VOR HAUPTSCHALTER
BEI: NETZSPG 400V/460V VOR HAUPTSCHALTER230 1 ST 922864 ELECTRIC EQUIPMENT 97073-524 TUERSCHALTER-UEBERWACHUNG
BEI: JIC-AUSFUERUNG OPTION KLIMATUER OPTION SCHALTSCHRANKBELEUCHTUNG
240 1 ST 922865 ELECTRIC EQUIPMENT 97073-525 UNTERSPANNUNGSAUSLOESUNGBEI: JIC-AUSFEHRUNG
260 1 ST 929496 ELECTRIC EQUIPMENT 97073-529 SPG.VERS. 230V VOR HAUPTSCHALTER270 1 ST 923041 ELECTRIC EQUIPMENT 97073-526 SCHALTSCHRANKBELEUCHTUNG
BEI: OPTION SCHALTSCHRANKBELEUCHTUNG280 1 ST 922866 ELECTRIC EQUIPMENT 97073-527 SPANNUNGSVERSORGUNG 24V DC290 1 ST 922867 ELECTRIC EQUIPMENT 97073-528 SPG.VERSORG. 110V/220V AC300 1 ST 922868 ELECTRIC EQUIPMENT 97073-530 SERVICESTECKDOSE DT. (IEC)310 1 ST 922869 ELECTRIC EQUIPMENT 97073-531 SERVICESTECKDOSE FRZ. (IEC)
BEI: FRANKREICH320 1 ST 922870 ELECTRIC EQUIPMENT 97073-532 SERVICESTECKDOSE US (JIC)
BEI: JIC-AUSFUEHRUNG (USA)340 1 ST 922871 ELECTRIC EQUIPMENT 97073-534 FI-SCHUTZSCHALTER
BEI: FRANKREICH360 1 ST 923042 ELECTRIC EQUIPMENT 97073-536 BETRIEBSSTUNDENZAEHLER 50HZ
BEI: NETZFREQUENZ 50HZ370 1 ST 923043 ELECTRIC EQUIPMENT 97073-537 BETRIEBSSTUNDENZAEHLER 60HZ
BEI: NETZFREQUENZ 60HZ400 1 ST 931222 ELECTRIC EQUIPMENT 97073-543 ZUSATZTRAFO FUER 6A-FU BEI JIC
BEI: TLF1500 UND 460V-NETZSPANNUNG410 1 ST 922872 ELECTRIC EQUIPMENT 97073-545 TURBINE MIT FREQUENZUMR. 6A
BEI: TLF1500420 1 ST 922873 ELECTRIC EQUIPMENT 97073-546 TURBINE MIT FREQUENZUMR. 12A
BEI: TLF1800, TLF2400, TLF3000430 1 ST 922874 ELECTRIC EQUIPMENT 97073-547 TURBINE MIT FREQUENZUMR. 33A
BEI: TLF3800440 1 ST 932795 ELECTRIC EQUIPMENT 97073-681 FREQUENZUMR. 900HZ LSM-NULLSER.450 1 ST 932797 ELECTRIC EQUIPMENT 97073-682 MAGNETLAGER. 900HZ LSM-NULLSER.500 1 ST 923052 ELECTRIC EQUIPMENT 97073-550 WAERMETAUSCHER510 1 ST 922875 ELECTRIC EQUIPMENT 97073-551 KLIMATUER
BEI: OPTION KLIMATUER (TROPEN)600 1 ST 922876 ELECTRIC EQUIPMENT 97073-555 HF-GENERATOR 11KW
BEI: TLF1500, TLF1800610 1 ST 922877 ELECTRIC EQUIPMENT 97073-556 HF-GENERATOR 15KW
BEI: TLF2400620 1 ST 922878 ELECTRIC EQUIPMENT 97073-557 HF-GENERATOR 18KW
BEI: TLF3000630 1 ST 922879 ELECTRIC EQUIPMENT 97073-558 HF-GENERATOR 22KW
BEI: TLF3800650 1 ST 941773 CABLE SET 97073-613 HF-GENERATOR660 1 ST 927108 ELECTRIC EQUIPMENT 97073-559 ZUSTIMMTASTER 10M670 1 ST 927109 ELECTRIC EQUIPMENT 97073-560 ZUSTIMMTASTER 15M
BEI: L4030S UND L6030S700 1 ST 922880 ELECTRIC EQUIPMENT 97073-561 VAKUUMPUMPE / VERSORGUNGSEINHEIT710 1 ST 923178 ELECTRIC EQUIPMENT 97073-562 EL. AUSRUESTUNG RESONATOR720 1 ST 922881 ELECTRIC EQUIPMENT 97073-563 TRENNVERSTAERKER LASERLEISTUNG721 1 ST 953104 ELECTRIC EQUIPMENT 97073-569 ABSCHALTBARER JUSTIERLASER810 1 ST 923054 ELECTRIC EQUIPMENT 97073-566 SICHERHEITSKREIS ZUSATZ BEI JIC
BEI: JIC-AUSFUEHRUNG820 1 ST 923055 ELECTRIC EQUIPMENT 97073-567 LASERWARNLAMPE900 1 ST 922882 ELECTRIC EQUIPMENT 97073-570 TASC-TERMINAL
Seite 1
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant910 1 ST 246963 PLUG 9706-18949 BLINDSTECKER X43 / +29-X1
BEI: OHNE BEDIENPULT920 1 ST 941774 CABLE SET 97073-607 BEDIENPULT INTERN
BEI: BEDIENPULT IM TUERAUSSCHNITT930 1 ST 941775 CABLE SET 97073-608 BEDIENPULT EXTERN STANDARD 17M
BEI: BEDIENPULT EXTERN 17m940 1 ST 941776 CABLE SET 97073-609 BEDIENPULT EXTERN 30M
BEI: BEDIENPULT EXTERN 30M (KABEL + UMSETZER)
1000 1 ST 941444 ELECTRIC EQUIPMENT 97073-573 TASC 2001010 1 ST 222583 CONTROL TASC 200 9558-H100 TASC 200 STAND.1010 1 ST 924291 CONTROL TASC 200 9558-H103 TASC 200 STD.+2. BIT-BUS-MODUL
BEI: ANSCHLUSS VON TRUMPF MASCHINEN1020 1 ST 924290 CONTROL TASC 200 9558-H102 TASC 200 STD.+ 2.E/A-KARTE
BEI: MASCHINENANSCHLUSS BCD1200 1 ST 922884 ELECTRIC EQUIPMENT 97073-575 STEUERANSCHLUSS LASER-KUEHLUNG1210 1 ST 922885 ELECTRIC EQUIPMENT 97073-576 LEISTUNGSANSCHLUSS KUEHLAGGREGAT
BEI: KUEHLAGGREGAT1220 1 ST 922886 ELECTRIC EQUIPMENT 97073-577 LEISTUNGSANSCHLUSS SONDERKUELAG.
BEI: SONDERKUHLAGGREGAT1230 1 ST 923044 ELECTRIC EQUIPMENT 97073-581 KLEMMLEISTE +59-X1
BEI: KUEHLAGGREGAT1240 1 ST 922887 ELECTRIC EQUIPMENT 97073-582 KLEMMLEISTE +59-X2
BEI: TUERSCHALTERUEBERWACHUNG, SCHRANK- BELEUCHTUNG
1250 1 ST 922888 ELECTRIC EQUIPMENT 97073-583 KLEMMLEISTE +59-X31300 1 ST 922890 ELECTRIC EQUIPMENT 97073-592 SCHNITTST.MASCHANSCH.STANDARD
BEI: MASCHINENANSCHLUSS1301 1 ST 955581 ELECTRIC EQUIPMENT 97073-591 SCHNITTST.MASCHANSCH.
BEI: MASCHINENANSCHLUSS OHNE HAUPTSCHALTER1310 1 ST 922889 ELECTRIC EQUIPMENT 97073-588 SCHNITTST.MASCHINENANSCH.LEISTUN
BEI: MASCHINENANSCHLUSS1320 1 ST 922891 ELECTRIC EQUIPMENT 97073-593 SCHNITTST.MASCHANSCH.BCD
BEI: MASCHINENANSCHLUSS BCD-SCHNITTSTELLE
920298 SWITCH CABINET 97073-513Version Klimatür
10 1 ST 920299 SWITCH CABINET 68511-302 600X1800X800, LEER20 1 ST 920295 MOUNTING PLATE 97073-517 MECH. KPL. STEUERUNGSTEIL30 1 ST 920294 MOUNTING PLATE 97073-518 MECH. KPL. LEISTUNGSTEIL50 2 ST 947450 CABLE CLAMP RAIL 68511-20-10 FUER 600(800)MM SCHRANKBREITE55 4 ST 947481 ANGLE PIECE 68511-20-30 FUER KABELABFANGSCHIENE60 1 ST 921599 SHEET 97073-513-60 FÜR NETZTEIL70 2 ST 117710 HEX. SCREW DIN 933 M6X12-8.8 VERZ. M6X12-8.8 VERZ. DIN 93380 2 ST 027979 PULLEY DIN 6797 A6,4-FDST A6,4-FDST DIN 679790 6 ST 479970 KAEFIGMUTTER M6 PS4164 RITTAL
100 745 MM 100823 BUS BAR 1622 WOEHNER110 4 ST 479971 NUT M8 PS 4165 RITTAL120 10 ST 146434 CONNECTING TERMINAL 1,5-16qmm 1284 WOEHNER130 4 ST 137114 CONNECTING TERMINAL 4-35qmm 1285 WOEHNER140 1 ST 137637 CONNECTING TERMINAL 16-70QMM 1287 WOEHNER150 1 ST 923179 COVER 97073-520 FUER WIDERSTAENDE160 1 ST 241372 HOLDER 9706-19365200 5 ST 134132 GROUND CONNECTOR 997.513 E-CU-BLANK M.LOCH 8,5MM KALTENBA
2x Rahmen Laserschr. - Rahmen HF-Schr.1x Bodenblech Leist. - Rahmen1x Bodenblech Steu. - Rahmen1x Montageplatte S. - Montageplatte L.
210 7 ST 134133 GROUND CONNECTOR 16qmm 400 lang 997.517 E-CU-BLANK M.LOCH 8,5MM KALTENBA2x Klimatür - Rahmen2x Tür - Rahmen1x Seitenwand - Rahmen1x Dach - Rahmen1x Bodenblech Mitte - Rahmen
220 22 ST 017140 HEX. SCREW DIN 933 M8X20-8.8 VERZ. M8X20-8.8 VERZ. DIN 933230 6 ST 022357 HEX. NUT ISO 4032 M8-10-A2G M8-10-A2G ISO 4032240 26 ST 023671 WASHER DIN 125 B8,4-ST B8,4-ST DIN 125250 26 ST 000650 SPRING RING DIN 7980 A8-FDST A8-FDST DIN 7980260 1 ST 342946 CLIP 14-18mm BK 18 NIEDAX270 1 ST 342947 CLIP 18-22mm BK 22 NIEDAX280 1 ST 342948 CLIP 22-26mm BK 26 NIEDAX290 4 ST 148557 RAISED HEAD SCREW ISO 7380 M12X20-A3P M12X20-A3P ISO 7380/UNBRAKO
Schrauben nach Entfernen der Kranösenim Schaltschrankdach eindrehen.
300 3 ST 146782 CLAMP STRAP 790-108 WAGO310 3 ST 341623 CLAMP STRAP 790-124 WAGO
920299 SWITCH CABINET 68511-302Kaufteil RittalVerwendung: TLF1500..3800 trubo
10 1 ST 922386 SIDE WALL 68511-302-10 FÜR SCHRANK MIT KLIMATÜR
Seite 2
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant30 1 ST 075439 CABLE SOCKET 600X800X200 RITTAL
bearbeitet nach 68511-30250 1 ST 923048 BAFFLE PLATE 68511-302-50 FÜR KLIMATÜR
unterhalb der Schaltplantaschemontiert
60 2 ST 145249 MOUNTING PS 4099006 GEM.ZCH.B1434100PS24 RITTAL70 3 ST 088287 CHASSIS SYSTEM PS 4372.0000 RITTAL80 1 ST 147499 DOOR 1700W 400V/50HZ 460V/60HZ SK 3317200 A RITTAL90 1 ST 142798 BAG FOR CIRCUIT DIAGRAMS 235040 RITTAL
an Innenseite Klimatür montiert100 1 ST 923102 REFINISHING OPERATION 68511-302-100150 1 ST 923049 BOTTOM SHEET 68511-302-150160 1 ST 923050 BOTTOM SHEET 68511-302-160170 1 ST 923051 BOTTOM SHEET 68511-302-170
**************************************** Befestigungsmaterial f. 2 Mon- **** tageplatten, lose beigelegt: **
210 2 ST 112542 SLIDING PIECE 207 347 RITTAL220 2 ST 112543 SLIDING PIECE 207 346 RITTAL230 2 ST 112544 HOLDING ANGLE 207 349 RITTAL240 2 ST 112545 HOLDING ANGLE 207 348 RITTAL250 4 ST 131103 PIN 207 343 RITTAL260 4 ST 112546 SUPPORTING ANGLE 209 966 RITTAL270 4 ST 131104 FIXING SCREW M8 207 345 RITTAL280 8 ST 131105 HEX. SCREW 200 382 M8X15 RITTAL290 8 ST 131106 WASHER 200 299 RITTAL300 2 ST 131107 LABEL 200 023 RITTAL310 4 ST 131108 WASHER 203 509 SZ 2335 RITTAL320 4 ST 131109 HEX. NUT 206 537 RITTAL330 4 ST 131110 HEX. SCREW 206 543 M8X30 RITTAL340 4 ST 131111 WASHER 206 545 RITTAL
**************************************360 4 ST 078908 ANGLE PIECE PS 4582.0000 RITTAL370 4 ST 096545 MOUNTING PS 4584 RITTAL380 2 ST 102542 ANGLE PIECE PS 4540 RITTAL
922809 SWITCH CABINET 97073-514Version Wärmetauscher
10 1 ST 923176 SWITCH CABINET 68511-303 600X1800X800, LEER20 1 ST 920295 MOUNTING PLATE 97073-517 MECH. KPL. STEUERUNGSTEIL30 1 ST 920294 MOUNTING PLATE 97073-518 MECH. KPL. LEISTUNGSTEIL40 1 ST 121565 HEAT EXCHANGER 1000-391 GROSS50 2 ST 947450 CABLE CLAMP RAIL 68511-20-10 FUER 600(800)MM SCHRANKBREITE55 4 ST 947481 ANGLE PIECE 68511-20-30 FUER KABELABFANGSCHIENE60 1 ST 921599 SHEET 97073-513-60 FÜR NETZTEIL70 2 ST 117710 HEX. SCREW DIN 933 M6X12-8.8 VERZ. M6X12-8.8 VERZ. DIN 93380 2 ST 027979 PULLEY DIN 6797 A6,4-FDST A6,4-FDST DIN 679790 6 ST 479970 KAEFIGMUTTER M6 PS4164 RITTAL
100 745 MM 100823 BUS BAR 1622 WOEHNER110 4 ST 479971 NUT M8 PS 4165 RITTAL120 10 ST 146434 CONNECTING TERMINAL 1,5-16qmm 1284 WOEHNER130 4 ST 137114 CONNECTING TERMINAL 4-35qmm 1285 WOEHNER140 1 ST 137637 CONNECTING TERMINAL 16-70QMM 1287 WOEHNER150 1 ST 923179 COVER 97073-520 FUER WIDERSTAENDE160 1 ST 241372 HOLDER 9706-19365200 5 ST 134132 GROUND CONNECTOR 997.513 E-CU-BLANK M.LOCH 8,5MM KALTENBA
2x Rahmen Laserschr. - Rahmen HF-Schr.1x Bodenblech Leist. - Rahmen1x Bodenblech Steu. - Rahmen1x Montageplatte S. - Montageplatte L.
210 7 ST 134133 GROUND CONNECTOR 16qmm 400 lang 997.517 E-CU-BLANK M.LOCH 8,5MM KALTENBA2x Klimatür - Rahmen2x Tür - Rahmen1x Seitenwand - Rahmen1x Dach - Rahmen1x Bodenblech Mitte - Rahmen
220 22 ST 017140 HEX. SCREW DIN 933 M8X20-8.8 VERZ. M8X20-8.8 VERZ. DIN 933230 6 ST 022357 HEX. NUT ISO 4032 M8-10-A2G M8-10-A2G ISO 4032240 26 ST 023671 WASHER DIN 125 B8,4-ST B8,4-ST DIN 125250 26 ST 000650 SPRING RING DIN 7980 A8-FDST A8-FDST DIN 7980260 1 ST 342946 CLIP 14-18mm BK 18 NIEDAX270 1 ST 342947 CLIP 18-22mm BK 22 NIEDAX280 1 ST 342948 CLIP 22-26mm BK 26 NIEDAX290 4 ST 148557 RAISED HEAD SCREW ISO 7380 M12X20-A3P M12X20-A3P ISO 7380/UNBRAKO
Schrauben nach Entfernen der Kranösenim Schaltschrankdach eindrehen.
300 3 ST 146782 CLAMP STRAP 790-108 WAGO310 3 ST 341623 CLAMP STRAP 790-124 WAGO
955426 ELECTRIC EQUIPMENT 97073-519ESD ALLGEMEIN
10 1 ST 342354 EARTHING GROUNDING FOR SWITCH CABINET 392-141 RS-COMPONENTS
Seite 3
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant20 1 ST 342507 EARTHING GROUNDING ESD 2050.750.10, 10MM DRUCKKNOPF DILL30 1 ST 342506 SPIRAL CABLE ESD 2100.752.10.10 DILL40 1 ST 149018 CLASP B=16mm L=200mm f. D=50 DK 7072.230 RITTAL
ZUR BEFESTIGUNG DES ARMBANDES UNDSPIRALKABELS NACH DER BENUTZUNG
50 1 ST 922300 BLECHSCHRAUBE BZ5,5X13 SZ2486 RITTAL60 10 ST 342508 CAUTION PLATE ESD D6mm 2850,6 DILL
941844 DOOR 97073-504mit Türausschnitt Bedienpult
10 1 ST 942234 DOOR 97073-504-10 MIT AUSSCHNITT F. BEDIENPULT20 1 ST 230759 HOUSING 9705-U30850 12 ST 022349 HEX. NUT ISO 4032 M6-10 GELB-A2G M6-10-A2G ISO 403260 12 ST 075515 WASHER DIN 125 B6,4-ST B6,4-ST DIN 12570 12 ST 075531 SPRING RING DIN 127 A6-FDST A6-FDST DIN 127
900483 CABINET 9707-241alle Maschinen außer TLC2530
10 1 ST 900253 ELECTRICAL INSTALLATION 9707-57620 1 ST 900258 CABLE 9707-57730 1 ST 903108 MOUNTING PLATE 9707-241-20 STEINHARDT40 1 ST 258537 HOLDER 9706-29050 ELBERT50 1 ST 258539 PLEXIGLASS SIGHT 100X80X0,5 +/-1 100X80X0,5 +/-1 NEON-REISS60 1 ST 209620 SHIELD 9703-3708 TLT70 1 ST 117795 VACUUM PUMP 1000-352 RB 0006-EILO BUSCH80 1 ST 146805 GAS MIXER KM40-3T/2S1 V11 536,300076 WITT90 1 ST 900487 SWITCH CABINET 1000-441 NACHARBEIT AUS MAT.NR.900479 RITTAL
100 1 ST 141195 HEAT EXCHANGER 140/6/2/2/64/W/1/WL/G/CU14R ROLLER110 1 ST 245741 ADAPTER 93613-58-40120 2 ST 090995 CHEESEHEAD SCREW DIN 912 M3X8-8.8 VERZ. M3X8-8.8 VERZ. DIN 912130 2 ST 071225 CHEESEHEAD SCREW DIN 912 M4X10-8.8 verz. M4X10-8.8 VERZ. DIN 912140 2 ST 084662 CHEESEHEAD SCREW DIN 912 M4X16-8.8 VERZ. M4X16-8.8 VERZ. DIN 912150 4 ST 137739 CHEESEHEAD SCREW DIN 912 M5X22-8.8-A2P M5X22-8.8-A2P DIN 912160 4 ST 089299 CHEESEHEAD SCREW DIN 912 M5X12-8.8 VERZ. M5X12-8.8 VERZ. DIN 912180 8 ST 115673 CHEESEHEAD SCREW DIN 912 M6X10-8.8 VERZ. M6X10-8.8 VERZ. DIN 912200 2 ST 130122 CHEESEHEAD SCREW DIN 912 M6x55-8.8 verz. M6X55-8.8 VERZ. DIN 912210 2 ST 109783 C/SK SCREW DIN 7991 M4X12 NIROSTA M4X12 NIROSTA DIN 7991230 4 ST 088282 HEX. NUT ISO 4032 M4-8-A2P M4-8-A2P ISO 4032270 2 ST 067427 STRAIGHT SCREW-IN UNION 1510-8/6-1/4 1510-8/6-1/4 CAMOZZI280 3 ST 067399 ELBOW SCREW-IN UNION 1500-8/6-1/8 1500-8/6-1/8 CAMOZZI280 2 ST 067399 ELBOW SCREW-IN UNION 1500-8/6-1/8 1500-8/6-1/8 CAMOZZI290 1 ST 088016 ELBOW SCREW-IN UNION 1500-10/8-3/8 1500-10/8-3/8 CAMOZZI300 3 ST 068300 ELBOW SCREW-IN UNION 1500-12/10-3/8 1500-12/10-3/8 CAMOZZI300 4 ST 068300 ELBOW SCREW-IN UNION 1500-12/10-3/8 1500-12/10-3/8 CAMOZZI310 2 ST 105519 ELBOW UNION 1493-12/10-3/8 1493-12/10-3/8 CAMOZZI320 1 ST 088882 ELBOW UNION 1493-6/4-1/4 1493-6/4-1/4 CAMOZZI330 1 ST 088918 STRAIGHT SCREW-IN UNION 1511-8/6-1/4 1511-8/6-1/4 CAMOZZI350 1 ST 105520 T-PIECE 2070-3/8-3/8 2070-3/8-3/8 CAMOZZI360 1 ST 067450 T-PIECE 1540-8/6 1540-8/6 CAMOZZI365 1 ST 106734 T-UNION 1410-12/10-3/8 1410-12/10-3/8 CAMOZZI370 2 ST 066202 ELBOW SCREW-IN UNION 1500-8/6-1/4 1500-8/6-1/4 CAMOZZI380 1 ST 129448 DOUBLE NIPPLE 2501-1/4-HO 2501-1/4-HO CAMOZZI390 2 ST 089943 DOUBLE NIPPLE 2500-3/8" 2500-3/8" CAMOZZI400 1 ST 107687 REDUCING NIPPLE 2520-1/4-3/8 2520-1/4-3/8 CAMOZZI400 2 ST 107687 REDUCING NIPPLE 2520-1/4-3/8 2520-1/4-3/8 CAMOZZI405 1 ST 107687 REDUCING NIPPLE 2520-1/4-3/8 2520-1/4-3/8 CAMOZZI410 2 ST 141259 2/2-WAY VALVE 9500372.0200.024.00 HERION420 1 ST 135349 VALVE BLOCK 9521662.0827.024.00 HERION430 1 ST 140283 NOZZLE 44-031/40 HINTERMAYR440 1 ST 132132 PRESSURE GAUGE TRANSFORM 46 AEB IMO460 1,5 M 092729 HOSE 6X8,0 6X8,0 POLYTETR460 1,2 M 092729 HOSE 6X8,0 6X8,0 POLYTETR470 0,7 M 092731 HOSE 10X12,0 10X12,0 POLYTETR470 1,5 M 092731 HOSE 10X12,0 10X12,0 POLYTETR480 1,2 M 139979 HOSE 8X6 BLACK 893033 PUR KELLERER490 0,35 M 121947 MARKING TAPE 2,0mmx9mmx16,5m ACRYLIC FOAM 4912 WEISS TEWIPACK500 1 ST 059510 SEALING CAP CV-PK-6 B CV-PK-6 B FESTO520 1 ST 140318 PASSAGE NR. 53520 MURRPLAS530 5 ST 137634 LEAD-IN SPOUT KDT 2 7,5-9 53506 MURRPLASTIK540 1 ST 088952 AXIAL FAN TYP 7450 PAPST550 1 ST 086641 PROT. SCREEN LZ 24 ZU LUEFTER TYP 7650 PAPST560 1 ST 062403 BULKHEAD UNION 1590-8/6 1590-8/6 CAMOZZI
933526 CABINET S98527-190alle Maschinen außer TLC2530
10 1 ST 900253 ELECTRICAL INSTALLATION 9707-57620 1 ST 900258 CABLE 9707-57730 1 ST 903108 MOUNTING PLATE 9707-241-20 STEINHARDT35 1 ST 905839 ADAPTER 9707-241-3040 1 ST 258537 HOLDER 9706-29050 ELBERT50 1 ST 258539 PLEXIGLASS SIGHT 100X80X0,5 +/-1 100X80X0,5 +/-1 NEON-REISS60 1 ST 209620 SHIELD 9703-3708 TLT
Seite 4
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant70 1 ST 149023 VACUUM PUMP P 173/1 1002-542 P 173/1 HYCO80 1 ST 146805 GAS MIXER KM40-3T/2S1 V11 536,300076 WITT90 1 ST 900487 SWITCH CABINET 1000-441 NACHARBEIT AUS MAT.NR.900479 RITTAL
100 1 ST 141195 HEAT EXCHANGER 140/6/2/2/64/W/1/WL/G/CU14R ROLLER110 1 ST 245741 ADAPTER 93613-58-40120 2 ST 090995 CHEESEHEAD SCREW DIN 912 M3X8-8.8 VERZ. M3X8-8.8 VERZ. DIN 912130 2 ST 071225 CHEESEHEAD SCREW DIN 912 M4X10-8.8 verz. M4X10-8.8 VERZ. DIN 912140 2 ST 084662 CHEESEHEAD SCREW DIN 912 M4X16-8.8 VERZ. M4X16-8.8 VERZ. DIN 912150 4 ST 137739 CHEESEHEAD SCREW DIN 912 M5X22-8.8-A2P M5X22-8.8-A2P DIN 912160 4 ST 089299 CHEESEHEAD SCREW DIN 912 M5X12-8.8 VERZ. M5X12-8.8 VERZ. DIN 912180 8 ST 115673 CHEESEHEAD SCREW DIN 912 M6X10-8.8 VERZ. M6X10-8.8 VERZ. DIN 912200 2 ST 130122 CHEESEHEAD SCREW DIN 912 M6x55-8.8 verz. M6X55-8.8 VERZ. DIN 912210 2 ST 109783 C/SK SCREW DIN 7991 M4X12 NIROSTA M4X12 NIROSTA DIN 7991230 4 ST 088282 HEX. NUT ISO 4032 M4-8-A2P M4-8-A2P ISO 4032270 2 ST 067427 STRAIGHT SCREW-IN UNION 1510-8/6-1/4 1510-8/6-1/4 CAMOZZI280 3 ST 067399 ELBOW SCREW-IN UNION 1500-8/6-1/8 1500-8/6-1/8 CAMOZZI280 2 ST 067399 ELBOW SCREW-IN UNION 1500-8/6-1/8 1500-8/6-1/8 CAMOZZI290 1 ST 088016 ELBOW SCREW-IN UNION 1500-10/8-3/8 1500-10/8-3/8 CAMOZZI300 3 ST 068300 ELBOW SCREW-IN UNION 1500-12/10-3/8 1500-12/10-3/8 CAMOZZI300 4 ST 068300 ELBOW SCREW-IN UNION 1500-12/10-3/8 1500-12/10-3/8 CAMOZZI310 2 ST 105519 ELBOW UNION 1493-12/10-3/8 1493-12/10-3/8 CAMOZZI320 1 ST 088882 ELBOW UNION 1493-6/4-1/4 1493-6/4-1/4 CAMOZZI330 1 ST 088918 STRAIGHT SCREW-IN UNION 1511-8/6-1/4 1511-8/6-1/4 CAMOZZI350 1 ST 105520 T-PIECE 2070-3/8-3/8 2070-3/8-3/8 CAMOZZI360 1 ST 067450 T-PIECE 1540-8/6 1540-8/6 CAMOZZI365 1 ST 106734 T-UNION 1410-12/10-3/8 1410-12/10-3/8 CAMOZZI370 2 ST 066202 ELBOW SCREW-IN UNION 1500-8/6-1/4 1500-8/6-1/4 CAMOZZI380 1 ST 129448 DOUBLE NIPPLE 2501-1/4-HO 2501-1/4-HO CAMOZZI390 2 ST 089943 DOUBLE NIPPLE 2500-3/8" 2500-3/8" CAMOZZI400 1 ST 107687 REDUCING NIPPLE 2520-1/4-3/8 2520-1/4-3/8 CAMOZZI400 2 ST 107687 REDUCING NIPPLE 2520-1/4-3/8 2520-1/4-3/8 CAMOZZI410 1 ST 141259 2/2-WAY VALVE 9500372.0200.024.00 HERION420 1 ST 135349 VALVE BLOCK 9521662.0827.024.00 HERION430 1 ST 140283 NOZZLE 44-031/40 HINTERMAYR440 1 ST 132132 PRESSURE GAUGE TRANSFORM 46 AEB IMO460 1,5 M 092729 HOSE 6X8,0 6X8,0 POLYTETR460 1,2 M 092729 HOSE 6X8,0 6X8,0 POLYTETR470 0,7 M 092731 HOSE 10X12,0 10X12,0 POLYTETR470 1,5 M 092731 HOSE 10X12,0 10X12,0 POLYTETR480 1,2 M 139979 HOSE 8X6 BLACK 893033 PUR KELLERER490 0,35 M 121947 MARKING TAPE 2,0mmx9mmx16,5m ACRYLIC FOAM 4912 WEISS TEWIPACK500 1 ST 059510 SEALING CAP CV-PK-6 B CV-PK-6 B FESTO520 1 ST 140318 PASSAGE NR. 53520 MURRPLAS530 5 ST 137634 LEAD-IN SPOUT KDT 2 7,5-9 53506 MURRPLASTIK540 1 ST 088952 AXIAL FAN TYP 7450 PAPST550 1 ST 086641 PROT. SCREEN LZ 24 ZU LUEFTER TYP 7650 PAPST560 1 ST 062403 BULKHEAD UNION 1590-8/6 1590-8/6 CAMOZZI570 1 ST 340872 2/2-WAY VALVE DN6 9501672.0827.02400 NORGREN-HERION580 4 ST 340352 METAL RUBBER BUMPER AD=25mm H=20mm ELASTO A-PUFFER 25X20 WEICH ELASTO-METALL
922860 SWITCH CABINET 97073-51210 1 ST 900935 TYPE PLATE 68511-10-1020 1 ST 900939 TYPE PLATE 68511-10-50 AM SCHALTSCHR. O. HAUPTSCHALTER30 220 ST 143092 LABEL 18X9mm ZTR 1809 PWR25 WEISS ROSENBAUM40 10 ST 125417 LABEL 1031-250.1 AUSGESCH.HAUPTSCH.UNTER SPANNUNG DEMMEL50 6 ST 029446 DANGER ARROW 01/003 50MM JAHN60 30 ST 085715 SYMBOL FOR EARTH 200WG RD12 JAHN
922862 ELECTRIC EQUIPMENT 97073-521NETZEINSPEISUNGEINSPEISUNG 400V
11 1 ST 093582 MAIN SWITCH NZM6-160-EA KLOECKNE.=L+1-S1.=L+1-DISC1
20 2 ST 086411 BUS BAR SUPPORT 1495 WOEHNER30 2 ST 145677 HOLDER 1017 WOEHNER40 0,45 M 100823 BUS BAR 1622 WOEHNER
L150 0,45 M 100823 BUS BAR 1622 WOEHNER
L260 0,45 M 100823 BUS BAR 1622 WOEHNER
L370 2 ST 145675 COVER 1019 WOEHNER80 1 ST 145676 BARRIER PROFILE 17X86X1100 01041, 60MM-SYSTEM WOEHNER
2x je 450mm90 1 ST 100815 TERMINAL BOARD 1412 WOEHNER
L1 L2 L3110 1 ST 144607 PROTECTIVE MOTOR SWITCH 28-40A 3RV10 31-4FA10 SIEMENS
.=L+1-Q1
.=L+1-CB1120 1 ST 146377 BUSBAR ADAPTER 8US12 61-5FM08 SIEMENS
.=L+1-Q1
Seite 5
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant.=L+1-CB1
160 2 ST 140350 TERMINAL 3RV19 15-5A SIEMENS170 1 ST 148278 BUS BAR 4-fach 45mm 3RV19 15-1C SIEMENS180 1 ST 148279 BUS BAR 5-fach 45mm 3RV19 15-1D SIEMENS190 3 ST 149152 CONNECTION BZ 266 KLOECKNER-MOELLER
.=L+1-S1
.=L+1-DISC1200 1 ST 101487 PROT.CONDUCTOR TERMINAL USLKG95 04 41 04 1 PHOENIX
(.=L+1-S1)(.=L+1-DISC1)
955579 ELECTRIC EQUIPMENT 97073-589NETZEINSPEISUNGEINSPEISUNG 400V OHNE HAUPTSCHALTER
20 2 ST 086411 BUS BAR SUPPORT 1495 WOEHNER30 2 ST 145677 HOLDER 1017 WOEHNER40 0,45 M 100823 BUS BAR 1622 WOEHNER
L150 0,45 M 100823 BUS BAR 1622 WOEHNER
L260 0,45 M 100823 BUS BAR 1622 WOEHNER
L370 2 ST 145675 COVER 1019 WOEHNER80 1 ST 145676 BARRIER PROFILE 17X86X1100 01041, 60MM-SYSTEM WOEHNER
2x je 450mm90 1 ST 100815 TERMINAL BOARD 1412 WOEHNER
L1 L2 L3110 1 ST 144607 PROTECTIVE MOTOR SWITCH 28-40A 3RV10 31-4FA10 SIEMENS
.=L+1-Q1
.=L+1-CB1120 1 ST 146377 BUSBAR ADAPTER 8US12 61-5FM08 SIEMENS
.=L+1-Q1
.=L+1-CB1160 2 ST 140350 TERMINAL 3RV19 15-5A SIEMENS170 1 ST 148278 BUS BAR 4-fach 45mm 3RV19 15-1C SIEMENS180 1 ST 148279 BUS BAR 5-fach 45mm 3RV19 15-1D SIEMENS200 1 ST 101487 PROT.CONDUCTOR TERMINAL USLKG95 04 41 04 1 PHOENIX
(.=L+1-S1)(.=L+1-DISC1)
210 3 ST 478176 HIGH CURRENT TERMINAL PHOENIX'=L+1-X1
220 1 ST 035064 END CLIP E/UK 12 01 44 2 PHOENIX'=L+1-X1
230 1 ST 084779 STRIP WITH NAMEPLATE KLM 10 04 30 6 PHOENIX'=L+1-X1
240 1 ST 035059 TOOTHED STRAP 1051003/UNBEDR. 1051003/UNBEDR.1 STREIFEN = 10 S PHOENIX'=L+1-X1
250 1 ST 955583 SHEET 97073-589-250 ABDECKBLECH FÜR HAUPTSCHALTERABDECKBLECH FUER HAUPTSCHALTER
260 3 ST 071225 CHEESEHEAD SCREW DIN 912 M4X10-8.8 verz. M4X10-8.8 VERZ. DIN 912ZUR BEFESTIGUNG DES ABDECKBLECHES
270 3 ST 088282 HEX. NUT ISO 4032 M4-8-A2P M4-8-A2P ISO 4032ZUR BEFESTIGUNG DES ABDECKBLECHES
280 3 ST 088283 PULLEY DIN 6797 A4,3-FDST VERZ. A4,3-FDST VERZ. DIN 6797ZUR BEFESTIGUNG DES ABDECKBLECHESDICHTMITTELZUR ABDICHTUNG DES HAUPSCHALTER -ABDECKBLECHES UM IP54 ZU GEWAERLEISTEN
922863 ELECTRIC EQUIPMENT 97073-522NETZEINSPEISUNGEINSPEISUNG 460V
12 1 ST 117308 MAIN SWITCH N6-160-CNA KLOECKNE.=L+1-S1.=L+1-DISC1
20 2 ST 086411 BUS BAR SUPPORT 1495 WOEHNER30 2 ST 145677 HOLDER 1017 WOEHNER40 0,45 M 100823 BUS BAR 1622 WOEHNER
L150 0,45 M 100823 BUS BAR 1622 WOEHNER
L260 0,45 M 100823 BUS BAR 1622 WOEHNER
L370 2 ST 145675 COVER 1019 WOEHNER80 1 ST 145676 BARRIER PROFILE 17X86X1100 01041, 60MM-SYSTEM WOEHNER
2x je 450mm90 1 ST 100815 TERMINAL BOARD 1412 WOEHNER
L1 L2 L3110 1 ST 144607 PROTECTIVE MOTOR SWITCH 28-40A 3RV10 31-4FA10 SIEMENS
.=L+1-Q1
.=L+1-CB1120 1 ST 146377 BUSBAR ADAPTER 8US12 61-5FM08 SIEMENS
Seite 6
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant.=L+1-Q1.=L+1-CB1
141 1 ST 142982 SWITCH 7-10A 3RV14 21-1JA10 SIEMENS.=L+1-Q2.=L+1-CB2
151 1 ST 146452 TRANSFORMER 5kVA 031-3013-0000 TYP DS 1250 ROLLER+FISCHER.=L+1-T2.=L+1-T2
160 2 ST 140350 TERMINAL 3RV19 15-5A SIEMENS170 1 ST 148278 BUS BAR 4-fach 45mm 3RV19 15-1C SIEMENS180 1 ST 148279 BUS BAR 5-fach 45mm 3RV19 15-1D SIEMENS190 3 ST 149152 CONNECTION BZ 266 KLOECKNER-MOELLER
.=L+1-S1
.=L+1-DISC1200 1 ST 101487 PROT.CONDUCTOR TERMINAL USLKG95 04 41 04 1 PHOENIX
(.=L+1-S1)(.=L+1-DISC1)
955580 ELECTRIC EQUIPMENT 97073-590NETZEINSPEISUNGEINSPEISUNG 460V OHNE HAUPTSCHALTER
20 2 ST 086411 BUS BAR SUPPORT 1495 WOEHNER30 2 ST 145677 HOLDER 1017 WOEHNER40 0,45 M 100823 BUS BAR 1622 WOEHNER
L150 0,45 M 100823 BUS BAR 1622 WOEHNER
L260 0,45 M 100823 BUS BAR 1622 WOEHNER
L370 2 ST 145675 COVER 1019 WOEHNER80 1 ST 145676 BARRIER PROFILE 17X86X1100 01041, 60MM-SYSTEM WOEHNER
2x je 450mm90 1 ST 100815 TERMINAL BOARD 1412 WOEHNER
L1 L2 L3110 1 ST 144607 PROTECTIVE MOTOR SWITCH 28-40A 3RV10 31-4FA10 SIEMENS
.=L+1-Q1
.=L+1-CB1120 1 ST 146377 BUSBAR ADAPTER 8US12 61-5FM08 SIEMENS
.=L+1-Q1
.=L+1-CB1141 1 ST 142982 SWITCH 7-10A 3RV14 21-1JA10 SIEMENS
.=L+1-Q2
.=L+1-CB2151 1 ST 146452 TRANSFORMER 5kVA 031-3013-0000 TYP DS 1250 ROLLER+FISCHER
.=L+1-T2
.=L+1-T2160 2 ST 140350 TERMINAL 3RV19 15-5A SIEMENS170 1 ST 148278 BUS BAR 4-fach 45mm 3RV19 15-1C SIEMENS180 1 ST 148279 BUS BAR 5-fach 45mm 3RV19 15-1D SIEMENS200 1 ST 101487 PROT.CONDUCTOR TERMINAL USLKG95 04 41 04 1 PHOENIX
(.=L+1-S1)(.=L+1-DISC1)
210 3 ST 478176 HIGH CURRENT TERMINAL PHOENIX'=L+1-X1
210 3 ST 478176 HIGH CURRENT TERMINAL PHOENIX'=L+1-X1
220 1 ST 035064 END CLIP E/UK 12 01 44 2 PHOENIX'=L+1-X1
220 1 ST 035064 END CLIP E/UK 12 01 44 2 PHOENIX'=L+1-X1
230 1 ST 084779 STRIP WITH NAMEPLATE KLM 10 04 30 6 PHOENIX'=L+1-X1
230 1 ST 084779 STRIP WITH NAMEPLATE KLM 10 04 30 6 PHOENIX'=L+1-X1
240 1 ST 035059 TOOTHED STRAP 1051003/UNBEDR. 1051003/UNBEDR.1 STREIFEN = 10 S PHOENIX'=L+1-X1
240 1 ST 035059 TOOTHED STRAP 1051003/UNBEDR. 1051003/UNBEDR.1 STREIFEN = 10 S PHOENIX'=L+1-X1
250 1 ST 955583 SHEET 97073-589-250 ABDECKBLECH FÜR HAUPTSCHALTERABDECKBLECH FUER HAUPTSCHALTER
260 3 ST 071225 CHEESEHEAD SCREW DIN 912 M4X10-8.8 verz. M4X10-8.8 VERZ. DIN 912ZUR BEFESTIGUNG DES ABDECKBLECHES
270 3 ST 088282 HEX. NUT ISO 4032 M4-8-A2P M4-8-A2P ISO 4032ZUR BEFESTIGUNG DES ABDECKBLECHES
280 3 ST 088283 PULLEY DIN 6797 A4,3-FDST VERZ. A4,3-FDST VERZ. DIN 6797ZUR BEFESTIGUNG DES ABDECKBLECHESDICHTMITTELZUR ABDICHTUNG DES HAUPSCHALTER -ABDECKBLECHES UM IP54 ZU GEWAERLEISTEN
922861 ELECTRIC EQUIPMENT 97073-523NETZSPANNUNG (400V/460V)
Seite 7
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 LieferantVOR HAUPTSCHALTER
10 1 ST 142994 PROTECTIVE MOTOR SWITCH 4,5-6,3A 3RV10 21-1GA10 SIEMENS.=L+1-Q3.=L+1-CB3
922864 ELECTRIC EQUIPMENT 97073-524TUERSCHALTER-UEBERWACHUNG
10 1 ST 146277 SWITCH 0,18-0,25A 3RV14 21-0CA10 SIEMENS.=L+1-Q4.=L+1-CB4
20 1 ST 111016 CONTROL TRANSFORMER 4AM34 41-8AB40.-OC, NACH DIN VDE SIEMENS.=L+1-T1.=L+1-T1
30 1 ST 095951 A.C. CIRCUIT BREAKER 5SX2 102-7 5SX2 102-7 SIEMENS.=L+1-F1.=L+1-CB01
40 1 ST 146278 CONTACTER 4kW 1S 24V AC 50/60Hz 3RT10 16-2AB01 SIEMENS.=L+1-K1.=L+1-CON1
50 1 ST 144447 AUX. SWITCH BLOCK 1S/2Ö 3RH19 11-2HA12 SIEMENS.=L+1-K1.=L+1-CON1
60 1 ST 146794 VARISTOR AC 24-48V DC 24-70V S00 3RT19 16-1BB00, OHNE LED SIEMENS.=L+1-K1.=L+1-CON1
70 4 ST 067773 SWITCH PS 4127 RITTAL.=L+1-S9 -S10 -S11 -S12.=L+1-DS9 -DS10 -DS11 -DS12
922865 ELECTRIC EQUIPMENT 97073-525UNTERSPANNUNGSAUSLOESUNG
10 1 ST 116019 KEY SWITCH QXJSS A17 QXJSS A17 SCHLEGEL.=L+1-S2.=L+1-KS2
20 1 ST 066982 CONTACT MAKER AT 2 AT 2 SCHLEGEL.=L+1-S2.=L+1-KS2
30 1 ST 111015 UNDER VOLTAGE RELEASE 24V 60HZ U-NZM6 KLOECKNER.=L+1-S1.=L+1-DISC1
929496 ELECTRIC EQUIPMENT 97073-529SPG.VERSORGUNG 230V VOR HAUPTSCHALTER
10 1 ST 143392 SWITCH 2,2-3,2A 3RV14 21-1DA10 SIEMENS.=L+2-Q1.=L+2-CB1
20 1 ST 120767 3-PHASE A.C.TRANSFORMER 4AM55 41-8AC40-OB SIEMENS.=L+2-T1.=L+2-T1
30 1 ST 095952 A.C. CIRCUIT BREAKER 5SX2 104-7 5SX2 104-7 SIEMENS.=L+2-F1.=L+2-CB01
923041 ELECTRIC EQUIPMENT 97073-526SCHALTSCHRANKBELEUCHTUNG
40 2 ST 146790 SWITCH CABINET LIGHTING 14W 475mm PS 4139.140, 230V 50HZ RITTAL.=L+2-E1 -E2.=L+2-E1 -E2
50 2 ST 146791 BUSHING SZ 2507.100 RITTAL.=L+2-E1 -E2.=L+2-E1 -E2
922866 ELECTRIC EQUIPMENT 97073-527SPANNUNGSVERSORGUNG 24V DC
10 1 ST 142991 PROTECTIVE MOTOR SWITCH 1,1-1,6A 3RV10 21-1AA10 SIEMENS.=L+4-Q1.=L+4-CB1
20 1 ST 138691 CURRENT SUPPLY 24V/20A 6EP1 436-1SH01 24V/20A SIEMENS.=L+4-G1.=L+4-PWS1
30 4 ST 128956 A.C. CIRCUIT BREAKER 5SX2 106-6 5SX2 106-6 NENNSTROM 6A, CHAR. B SIEMENS.=L+4-F1 -F2 -F4 -F5.=L+4-CB01 -CB02 -CB04 -CB05
40 1 ST 098356 POWER-SUPPLY UNIT DC/1A SCHOENBUCH.=L+4-G2.=L+4-PWS2
922867 ELECTRIC EQUIPMENT 97073-528SPANNUNGSVERSORGUNG 110V/230V AC
10 1 ST 143392 SWITCH 2,2-3,2A 3RV14 21-1DA10 SIEMENS.=L+4-Q2.=L+4-CB2
Seite 8
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant20 1 ST 120767 3-PHASE A.C.TRANSFORMER 4AM55 41-8AC40-OB SIEMENS
.=L+4-T1
.=L+4-T130 1 ST 095952 A.C. CIRCUIT BREAKER 5SX2 104-7 5SX2 104-7 SIEMENS
.=L+4-F10
.=L+4-CB010
922868 ELECTRIC EQUIPMENT 97073-530SERVICESTECKDOSE DT. (IEC)
10 1 ST 067779 SOCKET 800 572 ST3 LUETZE.=L+4-X1 / -X10.=L+4-X1 / -X10
922869 ELECTRIC EQUIPMENT 97073-531SERVICESTECKDOSE FRZ. (IEC)
10 1 ST 128853 SOCKET 800 573 FRANZOESISCHE AUSFUEHRUN LUETZE.=L+4-X1 / -X10.=L+4-X1 / -X10
922870 ELECTRIC EQUIPMENT 97073-532SERVICESTECKDOSE US. (JIC)
10 1 ST 095952 A.C. CIRCUIT BREAKER 5SX2 104-7 5SX2 104-7 SIEMENS.=L+4-F11.=L+4-CB011
20 1 ST 137326 SOCKET 15A 125V 4286 US-NORM BERKER.=L+4-X2 / -X11.=L+4-X2 / -X11
922871 ELECTRIC EQUIPMENT 97073-534FEHLERSTROMSCHUTZSCHALTER
10 1 ST 140767 SAFETY SWITCH 5SM1 312-6 SIEMENS.=L+4-Q4.=L+4-CB4
923042 ELECTRIC EQUIPMENT 97073-536BETRIEBSSTUNDENZAEHLER 50HZ
10 1 ST 093585 TIME METER 7KT5 745-1 SIEMENS.=L+4-P1.=L+4-HM1
923043 ELECTRIC EQUIPMENT 97073-537BETRIEBSSTUNDENZAEHLER 60HZ
10 1 ST 105961 TIME METER 7KT5 745-3 220V/60HZ SIEMENS.=L+4-P1.=L+4-HM1
931222 ELECTRIC EQUIPMENT 97073-543TURBINEMIT FREQUENZWANDLER 6A (nur bei 460V)
41 1 ST 146452 TRANSFORMER 5kVA 031-3013-0000 TYP DS 1250 ROLLER+FISCHER.=L+5-T1.=L+5-T1
922872 ELECTRIC EQUIPMENT 97073-545TURBINEMIT FREQUENZWANDLER 6A
11 1 ST 142982 SWITCH 7-10A 3RV14 21-1JA10 SIEMENS.=L+5-Q1.=L+5-CB1
20 1 ST 146377 BUSBAR ADAPTER 8US12 61-5FM08 SIEMENS30 1 ST 142937 SWITCH 1S/1Ö QUER 3RV19 01-1E SIEMENS
.=L+5-Q1
.=L+5-CB151 1 ST 126346 TRANSFORMER 10.FO.R13-L06A KEB
.=L+5-A1 -A2
.=L+5-A1 -A271 1 ST 143402 CONTACTER 4kW 1S 3HK 400V 3RT10 16-2BB41 SIEMENS
.=L+5-K1
.=L+5-CON181 1 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS
.=L+5-K1
.=L+5-CON1100 1 ST 143397 AUXILIARY CONTACTOR 4S 24V 3RH11 40-2BB40 SIEMENS
.=L+5-K2
.=L+5-CR2110 1 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS
.=L+5-K2
.=L+5-CR2120 1 ST 120547 HOLDER 09 33 000 9989 MIT TRAEGERELEMEN HARTING
.=L+5-X1
.=L+5-X1130 1 ST 053302 SOCKET INSERT 09 31 006 2701 HARTING
Seite 9
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant.=L+5-X1.=L+5-X1
922873 ELECTRIC EQUIPMENT 97073-546TURBINEMIT FREQUENZWANDLER 12A
12 1 ST 142984 SWITCH 14-20A 3RV14 21-4BA10 SIEMENS.=L+5-Q1.=L+5-CB1
20 1 ST 146377 BUSBAR ADAPTER 8US12 61-5FM08 SIEMENS30 1 ST 142937 SWITCH 1S/1Ö QUER 3RV19 01-1E SIEMENS
.=L+5-Q1
.=L+5-CB152 1 ST 146596 FREQUENCY CONVERTER 13.F4.COG-L12B 13.F4.COG-L12B KEB
.=L+5-A1 -A2
.=L+5-A1 -A261 1 ST 136853 FILTER FN 258-16-29 SCHAFFNE
.=L+5-A3
.=L+5-A372 1 ST 143403 CONTACTER 7,5kW/400V 3HK 3RT10 25-3BB40 SIEMENS
.=L+5-K1
.=L+5-CON182 1 ST 146932 DIODE DC 24V S0, WITHOUT LED 3RT19 26-1ER00 SIEMENS
.=L+5-K1
.=L+5-CON191 1 ST 146355 AUX. SWITCH BLOCK 1S 3RH19 21-2CA10 SIEMENS
.=L+5-K1
.=L+5-CON1100 1 ST 143397 AUXILIARY CONTACTOR 4S 24V 3RH11 40-2BB40 SIEMENS
.=L+5-K2
.=L+5-CR2110 1 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS
.=L+5-K2
.=L+5-CR2120 1 ST 120547 HOLDER 09 33 000 9989 MIT TRAEGERELEMEN HARTING
.=L+5-X1
.=L+5-X1130 1 ST 053302 SOCKET INSERT 09 31 006 2701 HARTING
.=L+5-X1
.=L+5-X1
922874 ELECTRIC EQUIPMENT 97073-547TURBINEMIT FREQUENZWANDLER 33A
13 1 ST 147091 SWITCH 28-40A 3RV14 31-4FA10 SIEMENS.=L+5-Q1.=L+5-CB1
20 1 ST 146377 BUSBAR ADAPTER 8US12 61-5FM08 SIEMENS30 1 ST 142937 SWITCH 1S/1Ö QUER 3RV19 01-1E SIEMENS
.=L+5-Q1
.=L+5-CB153 1 ST 146219 FREQUENCY CONVERTER 33A 16F.4.C2H4G00 KEB
.=L+5-A1 -A2
.=L+5-A1 -A273 1 ST 146280 CONTACTER 18,5kW 3RT10 35-3BB40 SIEMENS
.=L+5-K1
.=L+5-CON183 1 ST 147348 VOLTAGE REGULATOR 26073 MURRELEKTRONIK
.=L+5-K1
.=L+5-CON191 1 ST 146355 AUX. SWITCH BLOCK 1S 3RH19 21-2CA10 SIEMENS
.=L+5-K1
.=L+5-CON1100 1 ST 143397 AUXILIARY CONTACTOR 4S 24V 3RH11 40-2BB40 SIEMENS
.=L+5-K2
.=L+5-CR2110 1 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS
.=L+5-K2
.=L+5-CR2120 1 ST 120547 HOLDER 09 33 000 9989 MIT TRAEGERELEMEN HARTING
.=L+5-X1
.=L+5-X1130 1 ST 053302 SOCKET INSERT 09 31 006 2701 HARTING
.=L+5-X1
.=L+5-X1
932795 ELECTRIC EQUIPMENT 97073-681FREQUENZUMRICHTERTLF 3800; (900Hz) NULLSERIE
10 1 ST 932793 INSTRUMENT PLATE 97073-681-10----------------------------------------
100 5 ST 060828 MOUNTING CLIP DIN72571 1X12-ST 1X12-ST DIN72571
Seite 10
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant(für 4x4qmm-Kabel)
110 0,3 M 142279 HOSE SZ 2595 RITTAL(zwischen +5-L1 und +5-A1)
200 12 ST 149020 SET SCREW DIN 913 M6x35-A2P M6X35-A2P DIN 913210 1 SZ 475921 CONSTR.-UNIT PS 4580 RITTAL
-> nur Bolzen verwenden (6 Stk)220 7 ST 075515 WASHER DIN 125 B6,4-ST B6,4-ST DIN 125
(6x Blech/Bolzen; 1x Blech/PE)230 7 ST 075531 SPRING RING DIN 127 A6-FDST A6-FDST DIN 127
(6x Blech/Bolzen; 1x Blech/PE)240 6 ST 075493 HEX. NUT ISO 4032 M6-10-A2P M6-10-A2P ISO 4032
(Befestigung Blech auf Bolzen)400 1 ST 148059 SWITCH 18-25A 3RV14 31-4DA10 SIEMENS
.=L+5-Q1
.=L+5-CB1405 1 ST 120547 HOLDER 09 33 000 9989 MIT TRAEGERELEMEN HARTING
.=L+5-X1
.=L+5-X1410 1 ST 146377 BUSBAR ADAPTER 8US12 61-5FM08 SIEMENS
.=L+5-Q1
.=L+5-CB1420 1 ST 142937 SWITCH 1S/1Ö QUER 3RV19 01-1E SIEMENS
.=L+5-Q1
.=L+5-CB1430 1 ST 146280 CONTACTER 18,5kW 3RT10 35-3BB40 SIEMENS
.=L+5-K1
.=L+5-CON1440 1 ST 147348 VOLTAGE REGULATOR 26073 MURRELEKTRONIK
.=L+5-K1
.=L+5-CON1450 1 ST 146355 AUX. SWITCH BLOCK 1S 3RH19 21-2CA10 SIEMENS
.=L+5-K1
.=L+5-CON1460 1 ST 148426 THROTTLE DND32 LUST
.=L+5-L1
.=L+5-L1461 4 ST 023558 CHEESEHEAD SCREW DIN 84 M5X20-4.8 M5X20-4.8 DIN 84462 4 ST 134233 WASHER NR. 41305 WUERTH470 1 ST 148427 FILTER NFD35.0 LUST
.=L+5-A1
.=L+5-A1471 4 ST 018996 CHEESEHEAD SCREW DIN 84 M4X16-4.8 M4X16-4.8 DIN 84472 4 ST 021946 SPRING RING DIN 127 B4-FDST B4-FDST DIN 127480 0,54 M 340351 CABLE 4G4qmm abgeschirmt 3001 0544 OELFELX-190CY LAPP
.=L+5-A1 <-> =L+5-A2
.=L+5-A1 <-> =L+5-A2490 1 ST 148428 FREQUENCY CONVERTER VF1424L,HF08,OP2,S56 LUST
.=L+5-A2
.=L+5-A2491 4 ST 023558 CHEESEHEAD SCREW DIN 84 M5X20-4.8 M5X20-4.8 DIN 84492 4 ST 134233 WASHER NR. 41305 WUERTH520 1,5 M 340351 CABLE 4G4qmm abgeschirmt 3001 0544 OELFELX-190CY LAPP
.=L+5-A2 <-> =L+5-A3
.=L+5-A2 <-> =L+5-A3530 1 ST 340350 FILTER 25A 3AFS460-25SF LUST
.=L+5-A3
.=L+5-A3531 4 ST 088281 CHEESEHEAD SCREW DIN 912 M8X20-8.8 VERZ. M8X20-8.8 VERZ. DIN 912532 4 ST 116624 WASHER DIN 125 A8,4-ST VERZ. A8,4-ST VERZ. DIN 125533 4 ST 022012 SPRING RING DIN 127 A8-FDST A8-FDST DIN 127534 1 ST 117710 HEX. SCREW DIN 933 M6X12-8.8 VERZ. M6X12-8.8 VERZ. DIN 933
(PE/Blech)540 0,7 M 340351 CABLE 4G4qmm abgeschirmt 3001 0544 OELFELX-190CY LAPP
.=L+5-A3 <-> =L+5-X1
.=L+5-A3 <-> =L+5-X1560 1 ST 149175 FRAME FOR MODULE MCR 6 B 10381100 CONTACT
.=L+5-X1
.=L+5-X1570 1 ST 149216 SOCKET INSERT 3-POLIG MCB 3 CM 10382100 CONTACT
.=L+5-X1
.=L+5-X1580 1 ST 149179 SOCKET INSERT 10-POLIG MCB 10 CM 10382500 CONTACT
.=L+5-X1
.=L+5-X1590 4 ST 149930 SLEEVE CONTACT 6,0qmm 11215100 CONTACT
.=L+5-X1
.=L+5-X1600 2 ST 149181 SLEEVE CONTACT 0,75-1qmm 13163200 CONTACT
.=L+5-X1
.=L+5-X1610 1 ST 143397 AUXILIARY CONTACTOR 4S 24V 3RH11 40-2BB40 SIEMENS
.=L+5-K2
Seite 11
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant.=L+5-CON2
620 1 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS.=L+5-K2.=L+5-CON2
932797 ELECTRIC EQUIPMENT 97073-682MAGNETLAGEREGELUNG;TLF 3800 (900Hz) LSM-NULLSERIE
10 1 ST 932794 INSTRUMENT PLATE 97073-682-1030 2 ST 942386 SPACER SHEET 97073-682-30 SCHARNIERUNTERLAGE
----------------------------------------100 2 ST 149017 HINGE 218-9003 DIRAK110 4 ST 123183 C/SK SCREW DIN 7991 M5X10-8.8 VERZ. M5X10-8.8 VERZ. DIN 7991
Befestigung Geräteblech/Scharnier(für Anschraubscharnier)
120 1 ST 143411 HOLDER SZ 2591 RITTAL121 2 ST 023558 CHEESEHEAD SCREW DIN 84 M5X20-4.8 M5X20-4.8 DIN 84122 2 ST 068721 WASHER DIN 125 B5,3-ST B5,3-ST DIN 125123 2 ST 017825 SPRING RING DIN 127 A5-FDST A5-FDST DIN 127130 1200 MM 143410 HOSE SZ 2589 RITTAL140 65 MM 092695 BEARING RAIL NS 35/15 GELOCHT 12 01 73 0 PHOENIX
für =L+5-Q2141 2 ST 100552 RIVET 1821-0609 1821-0609 AVDEL150 2 ST 474575 SCHRAUBE ZYL DIN912 M5X12 8.8 ST VERZ
für Schelle160 1 ST 117710 HEX. SCREW DIN 933 M6X12-8.8 VERZ. M6X12-8.8 VERZ. DIN 933
für PE auf Blech210 1 ST 075531 SPRING RING DIN 127 A6-FDST A6-FDST DIN 127
für PE auf Blech220 1 ST 075515 WASHER DIN 125 B6,4-ST B6,4-ST DIN 125
für PE auf BlechGEWINDEFURCHENDE SENKKOPFSCHRAUBE M5X20(für Anschraubscharnier)Schrauben sind zu beziehen überFa. WÜRTHBest. Nr. 209 65 20
310 8 ST 068721 WASHER DIN 125 B5,3-ST B5,3-ST DIN 125Befestigung Geräteblech/Scharnier(für Anschraubscharnier)
320 5 ST 149018 CLASP B=16mm L=200mm f. D=50 DK 7072.230 RITTAL330 12 ST 922300 BLECHSCHRAUBE BZ5,5X13 SZ2486 RITTAL
5x Klettverschluß; 2x Blech/Chassis;1x PE/Rahmen; 4x Systemchassis
340 2 ST 131465 CLIP SZ 2350 F. KABELABFANGSCHIENE F. RITTAL350 1 ST 088287 CHASSIS SYSTEM PS 4372.0000 RITTAL
-!! Zusatzblech MLR-Befestigung !!!----------------------------------------
400 1 ST 142931 PROTECTIVE MOTOR SWITCH 2,2-3,2A 3RV10 21-1DA10 SIEMENS.=L+5-Q2.=L+5-CB2
410 1 ST 142937 SWITCH 1S/1Ö QUER 3RV19 01-1E SIEMENS.=L+5-Q2.=L+5-CB2
420 2 ST 477696 ANGLE OF THE END WAGOfür =L+5-Q2
430 1 ST 148432 FILTER FN 355-3/05 SCHAFFNER.=L+5-A4.=L+5-A4
431 2 ST 123044 CHEESEHEAD SCREW DIN 84 M5X12-8.8 VERZ. M5X12-8.8 VERZ. DIN 84432 2 ST 068721 WASHER DIN 125 B5,3-ST B5,3-ST DIN 125433 2 ST 017825 SPRING RING DIN 127 A5-FDST A5-FDST DIN 127441 1 ST 148433 ELECTRONIC UNIT (900Hz) MBE3-50 (900HZ) MECOS TRAXLER
.=L+5-A5
.=L+5-A5443 4 ST 123044 CHEESEHEAD SCREW DIN 84 M5X12-8.8 VERZ. M5X12-8.8 VERZ. DIN 84444 4 ST 068721 WASHER DIN 125 B5,3-ST B5,3-ST DIN 125445 4 ST 017825 SPRING RING DIN 127 A5-FDST A5-FDST DIN 127
923052 ELECTRIC EQUIPMENT 97073-550ZUBEHOER SCHALTSCHRANKKLIMATISIERUNGFUER W/L-WAERMETAUSCHER
10 1 ST 141749 REGULATOR OF TEMPERATURE SK 3110000 RITTAL.=L+9-S1.=L+9-TAS1
922875 ELECTRIC EQUIPMENT 97073-551ZUBEHOER SCHALTSCHRANKKLIMATISIERUNGFUER KLIMATUER
10 1 ST 141749 REGULATOR OF TEMPERATURE SK 3110000 RITTAL.=L+9-S1.=L+9-TAS1
21 1 ST 142980 SWITCH 2,8-4A 3RV14 21-1EA10 SIEMENS
Seite 12
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant.=L+9-Q1.=L+9-CB1
31 1 ST 142937 SWITCH 1S/1Ö QUER 3RV19 01-1E SIEMENS.=L+9-Q1.=L+9-CB1
922876 ELECTRIC EQUIPMENT 97073-555HF-GENERATOR 11..22KWHF-GENERATOR 11KW
11 1 ST 147139 SWITCH 0,28-0,4A 3RV14 21-0EA10 SIEMENS.=L+10-Q1.=L+10-CB1
20 1 ST 143392 SWITCH 2,2-3,2A 3RV14 21-1DA10 SIEMENS.=L+10-Q2.=L+10-CB2
30 1 ST 146614 SWITCH 0,45-0,63A 3RV14 21-0GA10 SIEMENS.=L+10-Q3.=L+10-CB3
41 1 ST 147091 SWITCH 28-40A 3RV14 31-4FA10 SIEMENS.=L+10-Q4.=L+10-CB4
51 1 ST 146377 BUSBAR ADAPTER 8US12 61-5FM08 SIEMENS.=L+10-Q4.=L+10-CB4
61 1 ST 142980 SWITCH 2,8-4A 3RV14 21-1EA10 SIEMENS.=L+10-Q5.=L+10-CB5
70 5 ST 142937 SWITCH 1S/1Ö QUER 3RV19 01-1E SIEMENS.=L+10-Q1 -Q2 -Q3 -Q4 -Q5.=L+10-CB1 -CB2 -CB3 -CB4 -CB5
80 3 ST 101485 FIXED RESISTOR FZB 135X35-25 STEHEND FRIZLEN.=L+10-R1 -R2 -R3.=L+10-RES1 -RES2 -RES3
100 2 ST 143399 AUXILIARY CONTACTOR 2S/2OE 3RH11 22-2BB40 SIEMENS.=L+10-K1 -K2.=L+10-CR1 -CR2
110 2 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS.=L+10-K1 -K2.=L+10-CR1 -CR2
121 3 ST 147717 CONTACTER 15kW 24V 3RT10 34-3BB40 SIEMENS.=L+10-K3 -K4 -K5.=L+10-CON3 -CON4 -CON5
130 3 ST 143401 AUX. SWITCH BLOCK 2S/2Ö 3RH19 21-2FA22 SIEMENS.=L+10-K3 -K4 -K5.=L+10-CON3 -CON4 -CON5
140 3 ST 147348 VOLTAGE REGULATOR 26073 MURRELEKTRONIK.=L+10-K3 -K4 -K5.=L+10-CON3 -CON4 -CON5
150 1 ST 143402 CONTACTER 4kW 1S 3HK 400V 3RT10 16-2BB41 SIEMENS.=L+10-K7.=L+10-CON7
160 1 ST 145557 AUX. SWITCH BLOCK 2S/2Ö 3RH19 11-2HA22 SIEMENS.=L+10-K7.=L+10-CON7
170 1 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS.=L+10-K7.=L+10-CON7
180 1 ST 341477 CONTACTER 5,5kW 1S 3RT10 17-2BB41 SIEMENS.=L+10-K8.=L+10-CON8
190 1 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS.=L+10-K8.=L+10-CON8
220 1 ST 341216 MODULE FLKMS-D25SUB/B-ZFK3DS/PE 22 95 93 6 PHOENIX.=L+10-X1.=L+10-X1
230 1 ST 139272 SOCKET INSERT 09 38 006 2711 HARTING.=L+10-X4.=L+10-X4
240 1 ST 139273 PIVOT INSERT 09 38 006 2611 HARTING.=L+10-X4.=L+10-X4
250 1 ST 120546 CLUTCH 09 33 000 9986 MIT ZUGENTLASTUNG HARTING.=L+10-X4.=L+10-X4
260 2 ST 120547 HOLDER 09 33 000 9989 MIT TRAEGERELEMEN HARTING.=L+10-X2 -X4.=L+10-X2 -X4
270 1 ST 062157 SOCKET INSERT 16pol. 09 33 016 2701 HARTING.=L+10-X2.=L+10-X2
280 1 ST 148853 RELAY 3Ac50/60HZ 400/460V 1W BA 9040.11/301, 0050352 DOLD
Seite 13
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant.=L+10-K13.=L+10-K13
922877 ELECTRIC EQUIPMENT 97073-556HF-GENERATOR 11..22KWHF-GENERATOR 15KW
11 1 ST 147139 SWITCH 0,28-0,4A 3RV14 21-0EA10 SIEMENS.=L+10-Q1.=L+10-CB1
20 1 ST 143392 SWITCH 2,2-3,2A 3RV14 21-1DA10 SIEMENS.=L+10-Q2.=L+10-CB2
30 1 ST 146614 SWITCH 0,45-0,63A 3RV14 21-0GA10 SIEMENS.=L+10-Q3.=L+10-CB3
42 1 ST 850896 SWITCH 45-63A 3RV10 41-4JA10 SIEMENS.=L+10-Q4.=L+10-CB4
52 1 ST 146354 BUSBAR ADAPTER 8US11 11-4SM00 SIEMENS.=L+10-Q4.=L+10-CB4
61 1 ST 142980 SWITCH 2,8-4A 3RV14 21-1EA10 SIEMENS.=L+10-Q5.=L+10-CB5
70 5 ST 142937 SWITCH 1S/1Ö QUER 3RV19 01-1E SIEMENS.=L+10-Q1 -Q2 -Q3 -Q4 -Q5.=L+10-CB1 -CB2 -CB3 -CB4 -CB5
80 3 ST 101485 FIXED RESISTOR FZB 135X35-25 STEHEND FRIZLEN.=L+10-R1 -R2 -R3.=L+10-RES1 -RES2 -RES3
100 2 ST 143399 AUXILIARY CONTACTOR 2S/2OE 3RH11 22-2BB40 SIEMENS.=L+10-K1 -K2.=L+10-CR1 -CR2
110 2 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS.=L+10-K1 -K2.=L+10-CR1 -CR2
122 3 ST 146280 CONTACTER 18,5kW 3RT10 35-3BB40 SIEMENS.=L+10-K3 -K4 -K5.=L+10-CON3 -CON4 -CON5
130 3 ST 143401 AUX. SWITCH BLOCK 2S/2Ö 3RH19 21-2FA22 SIEMENS.=L+10-K3 -K4 -K5.=L+10-CON3 -CON4 -CON5
140 3 ST 147348 VOLTAGE REGULATOR 26073 MURRELEKTRONIK.=L+10-K3 -K4 -K5.=L+10-CON3 -CON4 -CON5
150 1 ST 143402 CONTACTER 4kW 1S 3HK 400V 3RT10 16-2BB41 SIEMENS.=L+10-K7.=L+10-CON7
160 1 ST 145557 AUX. SWITCH BLOCK 2S/2Ö 3RH19 11-2HA22 SIEMENS.=L+10-K7.=L+10-CON7
170 1 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS.=L+10-K7.=L+10-CON7
180 1 ST 341477 CONTACTER 5,5kW 1S 3RT10 17-2BB41 SIEMENS.=L+10-K8.=L+10-CON8
190 1 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS.=L+10-K8.=L+10-CON8
220 1 ST 341216 MODULE FLKMS-D25SUB/B-ZFK3DS/PE 22 95 93 6 PHOENIX.=L+10-X1.=L+10-X1
230 1 ST 139272 SOCKET INSERT 09 38 006 2711 HARTING.=L+10-X4.=L+10-X4
240 1 ST 139273 PIVOT INSERT 09 38 006 2611 HARTING.=L+10-X4.=L+10-X4
250 1 ST 120546 CLUTCH 09 33 000 9986 MIT ZUGENTLASTUNG HARTING.=L+10-X4.=L+10-X4
260 2 ST 120547 HOLDER 09 33 000 9989 MIT TRAEGERELEMEN HARTING.=L+10-X2 -X4.=L+10-X2 -X4
270 1 ST 062157 SOCKET INSERT 16pol. 09 33 016 2701 HARTING.=L+10-X2.=L+10-X2
280 1 ST 148853 RELAY 3Ac50/60HZ 400/460V 1W BA 9040.11/301, 0050352 DOLD.=L+10-K13.=L+10-K13
Seite 14
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant922878 ELECTRIC EQUIPMENT 97073-557
HF-GENERATOR 11..22KWHF-GENERATOR 18KW
11 1 ST 147139 SWITCH 0,28-0,4A 3RV14 21-0EA10 SIEMENS.=L+10-Q1.=L+10-CB1
20 1 ST 143392 SWITCH 2,2-3,2A 3RV14 21-1DA10 SIEMENS.=L+10-Q2.=L+10-CB2
30 1 ST 146614 SWITCH 0,45-0,63A 3RV14 21-0GA10 SIEMENS.=L+10-Q3.=L+10-CB3
42 1 ST 850896 SWITCH 45-63A 3RV10 41-4JA10 SIEMENS.=L+10-Q4.=L+10-CB4
52 1 ST 146354 BUSBAR ADAPTER 8US11 11-4SM00 SIEMENS.=L+10-Q4.=L+10-CB4
61 1 ST 142980 SWITCH 2,8-4A 3RV14 21-1EA10 SIEMENS.=L+10-Q5.=L+10-CB5
70 5 ST 142937 SWITCH 1S/1Ö QUER 3RV19 01-1E SIEMENS.=L+10-Q1 -Q2 -Q3 -Q4 -Q5.=L+10-CB1 -CB2 -CB3 -CB4 -CB5
80 3 ST 101485 FIXED RESISTOR FZB 135X35-25 STEHEND FRIZLEN.=L+10-R1 -R2 -R3.=L+10-RES1 -RES2 -RES3
100 2 ST 143399 AUXILIARY CONTACTOR 2S/2OE 3RH11 22-2BB40 SIEMENS.=L+10-K1 -K2.=L+10-CR1 -CR2
110 2 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS.=L+10-K1 -K2.=L+10-CR1 -CR2
123 3 ST 146279 CONTACTER 22kW 3RT10 36-3BB40 SIEMENS.=L+10-K3 -K4 -K5.=L+10-CON3 -CON4 -CON5
130 3 ST 143401 AUX. SWITCH BLOCK 2S/2Ö 3RH19 21-2FA22 SIEMENS.=L+10-K3 -K4 -K5.=L+10-CON3 -CON4 -CON5
140 3 ST 147348 VOLTAGE REGULATOR 26073 MURRELEKTRONIK.=L+10-K3 -K4 -K5.=L+10-CON3 -CON4 -CON5
150 1 ST 143402 CONTACTER 4kW 1S 3HK 400V 3RT10 16-2BB41 SIEMENS.=L+10-K7.=L+10-CON7
160 1 ST 145557 AUX. SWITCH BLOCK 2S/2Ö 3RH19 11-2HA22 SIEMENS.=L+10-K7.=L+10-CON7
170 1 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS.=L+10-K7.=L+10-CON7
180 1 ST 341477 CONTACTER 5,5kW 1S 3RT10 17-2BB41 SIEMENS.=L+10-K8.=L+10-CON8
190 1 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS.=L+10-K8.=L+10-CON8
220 1 ST 341216 MODULE FLKMS-D25SUB/B-ZFK3DS/PE 22 95 93 6 PHOENIX.=L+10-X1.=L+10-X1
230 1 ST 139272 SOCKET INSERT 09 38 006 2711 HARTING.=L+10-X4.=L+10-X4
240 1 ST 139273 PIVOT INSERT 09 38 006 2611 HARTING.=L+10-X4.=L+10-X4
250 1 ST 120546 CLUTCH 09 33 000 9986 MIT ZUGENTLASTUNG HARTING.=L+10-X4.=L+10-X4
260 2 ST 120547 HOLDER 09 33 000 9989 MIT TRAEGERELEMEN HARTING.=L+10-X2 -X4.=L+10-X2 -X4
270 1 ST 062157 SOCKET INSERT 16pol. 09 33 016 2701 HARTING.=L+10-X2.=L+10-X2
280 1 ST 148853 RELAY 3Ac50/60HZ 400/460V 1W BA 9040.11/301, 0050352 DOLD.=L+10-K13.=L+10-K13
922879 ELECTRIC EQUIPMENT 97073-558HF-GENERATOR 11..22KWHF-GENERATOR 22KW
Seite 15
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant12 1 ST 147988 SWITCH 0,9-1,25A 3RV14 21-0KA10 SIEMENS
.=L+10-Q1
.=L+10-CB120 1 ST 143392 SWITCH 2,2-3,2A 3RV14 21-1DA10 SIEMENS
.=L+10-Q2
.=L+10-CB230 1 ST 146614 SWITCH 0,45-0,63A 3RV14 21-0GA10 SIEMENS
.=L+10-Q3
.=L+10-CB342 1 ST 850896 SWITCH 45-63A 3RV10 41-4JA10 SIEMENS
.=L+10-Q4
.=L+10-CB452 1 ST 146354 BUSBAR ADAPTER 8US11 11-4SM00 SIEMENS
.=L+10-Q4
.=L+10-CB462 1 ST 142982 SWITCH 7-10A 3RV14 21-1JA10 SIEMENS
.=L+10-Q5
.=L+10-CB570 5 ST 142937 SWITCH 1S/1Ö QUER 3RV19 01-1E SIEMENS
.=L+10-Q1 -Q2 -Q3 -Q4 -Q5
.=L+10-CB1 -CB2 -CB3 -CB4 -CB580 3 ST 101485 FIXED RESISTOR FZB 135X35-25 STEHEND FRIZLEN
.=L+10-R1 -R2 -R3
.=L+10-RES1 -RES2 -RES391 3 ST 137941 FIXED RESISTOR FZB 50X16-40 FRIZLEN
.=L+10-R4 -R5 -R6
.=L+10-RES4 -RES5 -RES6100 2 ST 143399 AUXILIARY CONTACTOR 2S/2OE 3RH11 22-2BB40 SIEMENS
.=L+10-K1 -K2
.=L+10-CR1 -CR2110 2 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS
.=L+10-K1 -K2
.=L+10-CR1 -CR2124 3 ST 146356 CONTACTER 30kW 3RT10 44-3BB40 SIEMENS
.=L+10-K3 -K4 -K5
.=L+10-CON3 -CON4 -CON5130 3 ST 143401 AUX. SWITCH BLOCK 2S/2Ö 3RH19 21-2FA22 SIEMENS
.=L+10-K3 -K4 -K5
.=L+10-CON3 -CON4 -CON5140 3 ST 147348 VOLTAGE REGULATOR 26073 MURRELEKTRONIK
.=L+10-K3 -K4 -K5
.=L+10-CON3 -CON4 -CON5150 1 ST 143402 CONTACTER 4kW 1S 3HK 400V 3RT10 16-2BB41 SIEMENS
.=L+10-K7
.=L+10-CON7160 1 ST 145557 AUX. SWITCH BLOCK 2S/2Ö 3RH19 11-2HA22 SIEMENS
.=L+10-K7
.=L+10-CON7170 1 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS
.=L+10-K7
.=L+10-CON7180 1 ST 341477 CONTACTER 5,5kW 1S 3RT10 17-2BB41 SIEMENS
.=L+10-K8
.=L+10-CON8190 1 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS
.=L+10-K8
.=L+10-CON8201 1 ST 143402 CONTACTER 4kW 1S 3HK 400V 3RT10 16-2BB41 SIEMENS
.=L+10-K11
.=L+10-CON11211 1 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS
.=L+10-K11
.=L+10-CON11220 1 ST 341216 MODULE FLKMS-D25SUB/B-ZFK3DS/PE 22 95 93 6 PHOENIX
.=L+10-X1
.=L+10-X1230 1 ST 139272 SOCKET INSERT 09 38 006 2711 HARTING
.=L+10-X4
.=L+10-X4240 1 ST 139273 PIVOT INSERT 09 38 006 2611 HARTING
.=L+10-X4
.=L+10-X4250 1 ST 120546 CLUTCH 09 33 000 9986 MIT ZUGENTLASTUNG HARTING
.=L+10-X4
.=L+10-X4260 2 ST 120547 HOLDER 09 33 000 9989 MIT TRAEGERELEMEN HARTING
.=L+10-X2 -X4
.=L+10-X2 -X4270 1 ST 062157 SOCKET INSERT 16pol. 09 33 016 2701 HARTING
.=L+10-X2
.=L+10-X2280 1 ST 148853 RELAY 3Ac50/60HZ 400/460V 1W BA 9040.11/301, 0050352 DOLD
Seite 16
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant.=L+10-K13.=L+10-K13
941773 CABLE SET 97073-613HF-GENERATOR IS11..22
10 1 ST 923924 CABLE VERSORG 16P 2,0M 6853-109.=L+10-W2
20 1 ST 941905 CABLE SIGNAL 25P 3,0M 6853-55330 1 ST 240141 CABLE 9706-20728 PE-LEITUNG HF-GENERATOR40 1 ST 254430 LIGHT GUIDE 6855-52 KPL 3XHP 3.0M
927108 ELECTRIC EQUIPMENT 97073-559ZUSTIMMTASTER 10M
10 1 ST 099302 SWITCH 10m ZSA2A2G10A NR. 055407 EUCHNER
927109 ELECTRIC EQUIPMENT 97073-560ZUSTIMMTASTER 15M
10 1 ST 147480 SWITCH 15m ZSA2A2G15A NR. 057007 EUCHNER
922880 ELECTRIC EQUIPMENT 97073-561VERSORGUNGSEINHEIT (VAKUUMPUMPE)
10 1 ST 142991 PROTECTIVE MOTOR SWITCH 1,1-1,6A 3RV10 21-1AA10 SIEMENS.=L+17-Q1.=L+17-CB1
20 1 ST 142937 SWITCH 1S/1Ö QUER 3RV19 01-1E SIEMENS.=L+17-Q1.=L+17-CB1
30 1 ST 143402 CONTACTER 4kW 1S 3HK 400V 3RT10 16-2BB41 SIEMENS.=L+17-K1.=L+17-CON1
40 1 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS.=L+17-K1.=L+17-CON1
50 2 ST 129319 HOLDER 09 33 000 9988 MIT TRAEGERELEMEN HARTING.=L+17-X1 +59-X11.=L+17-X1 +59-X11
60 1 ST 067127 SOCKET INSERT 6pol. 09 33 006 2701 HARTING.=L+17-X1.=L+17-X1
70 1 ST 341214 MODULE FLKMS-D9SUB/B/ZFKKDS/PE 22 95 94 9 PHOENIX.=L+17-X4.=L+17-X4
80 1 ST 118354 SOCKET INSERT 09 16 024 3101 HARTING.=L+59-X11.=L+59-X11
90 19 ST 069252 CRIMP CONTACT 09 15 000 6203 HARTING.=L+59-X11.=L+59-X11
100 1 ST 146229 RING ID 12,8mm 310-349 SCHAFFNER.=L+17-FERRIT1.=L+17-FERRIT1
923178 ELECTRIC EQUIPMENT 97073-562RESONATOR
10 1 ST 341214 MODULE FLKMS-D9SUB/B/ZFKKDS/PE 22 95 94 9 PHOENIX.=L+19-X1.=L+19-X1
20 1 ST 120547 HOLDER 09 33 000 9989 MIT TRAEGERELEMEN HARTING.=L+59-X5.=L+59-X5
30 1 ST 069468 SOCKET INSERT 09 21 040 3101 HARTING.=L+59-X5.=L+59-X5
40 30 ST 069252 CRIMP CONTACT 09 15 000 6203 HARTING.=L+59-X5.=L+59-X5
50 1 ST 146229 RING ID 12,8mm 310-349 SCHAFFNER.=L+19-FERRIT1.=L+19-FERRIT1
60 1 ST 341242 RING ID 35,55mm 310-373 SCHAFFNER.=L+59-FERRIT1.=L+59-FERRIT1
922881 ELECTRIC EQUIPMENT 97073-563TRENNVERSTAERKER LASERLEISTUNG
10 1 ST 138267 AMPLIFIER TYP 4310A2 NR. 1148946 KNICK.=L+19-N3.=L+19-AMP3
953104 ELECTRIC EQUIPMENT 97073-569ABSCHALTBARER JUSTIERLASER
10 1 ST 146235 TIME LAG RELAY 24V DC 3RP15 05-1BP30 SIEMENS
Seite 17
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant.=L+19-K1.=L+19-TR1
20 1 ST 106465 RELAY EMG 10-REL/KSR-G24/21-LC 29 42 15 3 PHOENIX.=L+19-K2.=L+19-CR2
923053 ELECTRIC EQUIPMENT 97073-565SICHERHEITSKREIS
10 1 ST 143402 CONTACTER 4kW 1S 3HK 400V 3RT10 16-2BB41 SIEMENS.=L+22-K1.=L+22-CON1
20 1 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS.=L+22-K1.=L+22-CON1
30 1 ST 142334 EMERGENCY STOP RELAY 3TK28 06-0BB4 SIEMENS.=L+22-K2.=L+22-CR2
40 1 ST 106465 RELAY EMG 10-REL/KSR-G24/21-LC 29 42 15 3 PHOENIX.=L+22-K3.=L+22-CR3
50 4 ST 143397 AUXILIARY CONTACTOR 4S 24V 3RH11 40-2BB40 SIEMENS.=L+22-K4 -K5 -K6 -K7.=L+22-CR4 -CR5 -CR6 -CR7
60 4 ST 143400 AUX. SWITCH BLOCK 4Ö 3RH19 11-2GA04 SIEMENS.=L+22-K4 -K5 -K6 -K7.=L+22-CR4 -CR5 -CR6 -CR7
70 3 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS.=L+22-K4 -K6 -K7.=L+22-CR4 -CR6 -CR7
80 1 ST 140356 INTERFERENCE INVERTER 12-250V DC 3RT19 16-1DG00 SIEMENS.=L+22-K5.=L+22-CR5
923054 ELECTRIC EQUIPMENT 97073-566SICHERHEITSKREIS ZUSATZ BEI JIC
10 2 ST 116019 KEY SWITCH QXJSS A17 QXJSS A17 SCHLEGEL.=L+22-S20 -S21.=L+22-KS20 -KS21
20 2 ST 066982 CONTACT MAKER AT 2 AT 2 SCHLEGEL.=L+22-S20 -S21.=L+22-KS20 -KS21
923055 ELECTRIC EQUIPMENT 97073-567LASERWARNLAMPE
10 1 ST 143397 AUXILIARY CONTACTOR 4S 24V 3RH11 40-2BB40 SIEMENS.=L+23-K1.=L+23-CR1
20 1 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS.=L+23-K1.=L+23-CR1
30 1 ST 099893 CURRENT RELAY 2.450.111.00 A1/A2=AC 220-240V SCHIELE.=L+23-K2.=L+23-CR2
40 1 ST 136020 WARNING LAMP 850 100 38 WERMA.=L+23-H1.=L+23-LT1
50 1 ST 135667 LIGHT BULB 7W 24V 955 015 35 ZU ID-NR. 123579 WERMA.=L+23-H1.=L+23-LT1
922882 ELECTRIC EQUIPMENT 97073-570TASC-TERMINAL
10 1 ST 131874 A.C. CIRCUIT BREAKER 5SX2 103-7 5SX2 103-7 C-CHARAKTERISTIK SIEMENS.=L+29-F1.=L+29-CB01
20 1 ST 147881 FILTER FN 612-3/06 SCHAFFNER.=L+29-Z1.=L+29-Z1
30 1 ST 108270 MODULE FLKMS-D25 SUB/B 22 81 75 9 PHOENIX.=L+29-X1.=L+29-X1
50 1 ST 260821 CABLE 97088-560-10.=L+29-X2.=L+29-X2
60 1 ST 112023 MODULE FLKM-D 9 SUB/B 22 81 18 6 PHOENIX.=L+29-X2.=L+29-X2
941774 CABLE SET 97073-607KABELSATZ BEDIENPULT INTERN
10 1 ST 900828 CABLE 9707-580-10TUERE-BEDIENPULT 1,0M
Seite 18
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant20 1 ST 900843 CABLE SIGNAL 25P 1,0M 6853-551
TUERE-BEDIENPULT 1,0M30 1 ST 941840 CABLE 97073-607-40
SCHALTSCHRANK-TUERE 2,5M40 1 ST 941842 CABLE 97073-607-50
SCHALTSCHRANK-TUERE 2,5M50 2 ST 146782 CLAMP STRAP 790-108 WAGO60 1 ST 060771 MOUNTING CLIP DIN72571 1X6-ST 1X6-ST DIN7257170 1 ST 060798 MOUNTING CLIP DIN72571 1X8-ST 1X8-ST DIN7257180 2 ST 130080 DOUBLE-ACTING CYLINDER D40 HUB320 0 822 321 009 BOSCH90 2 ST 118357 SPRING RING DIN 127 A4-FDST VERZ. A4-FDST VERZ. DIN 127
100 2 ST 088282 HEX. NUT ISO 4032 M4-8-A2P M4-8-A2P ISO 4032
941775 CABLE SET 97073-608KABELSATZ BEDIENPULT EXTERN 17,0M
10 1 ST 936195 CABLE SIGNAL 25P 17,0M 6853-553SCHALTSCHRANK-BEDIENPULT
20 1 ST 941843 CABLE 97073-608-10SCHALTSCHRANK-BEDIENPULT
30 2 ST 146782 CLAMP STRAP 790-108 WAGO
941776 CABLE SET 97073-60930m Option für TASC300
10 1 ST 941906 CABLE SIGNAL 25P 30,0M 6853-55320 2 ST 900921 HOLDING ANGLE 9707-581-2030 2 ST 139772 MODULE OZDV 2451P 943316-021 HIRSCHMANN40 1 ST 139773 CABLE 0KDB 1000-C/BFOC 30M 937604-030 EHRET50 2 ST 139774 CABLE SERIELL 3M DSUB25-DSUB9 EHRET60 1 ST 139775 PLUG SUB-D 9-POLIG 5620110 EHRET70 1 ST 146782 CLAMP STRAP 790-108 WAGO
941444 ELECTRIC EQUIPMENT 97073-573TASC 200
10 1 ST 941955 CABLE 97073-573-10 ANALOG E/A 37-POLIG.=L+30-XANEA.=L+30-XANEA
20 2 ST 220599 CABLE 9704-11879 DIGITAL E/A 37-POLIG TLT.=L+30-XE2 -XA2.=L+30-XE2 -XA2
30 1 ST 220600 CABLE 9704-11880 DIGITAL E/A 15-POLIG TLT.=L+30-XDEA.=L+30-XDEA
40 1 ST 131874 A.C. CIRCUIT BREAKER 5SX2 103-7 5SX2 103-7 C-CHARAKTERISTIK SIEMENS.=L+30-F1.=L+30-CB01
50 1 ST 147881 FILTER FN 612-3/06 SCHAFFNER.=L+30-Z1.=L+30-Z1
60 1 ST 088427 PLUG PART 17 57 07 7 MSTB2,5/8-ST-5.08 PHOENIX.=L+30-A2.=L+30-A2
70 2 ST 096770 PLUG PART 17 57 01 9 MSTB2,5/2-ST-5,08 PHOENIX.=L+30-BE1 -BA1.=L+30-BE1 -BA1
80 1 ST 102436 PLUG PART 17 57 02 2 MSTB2,5/3-ST-5,08 PHOENIX.=L+30-BAE1.=L+30-BAE1
90 1 ST 341217 MODULE FLKMS-D37SUB/B/ZFK3DS/PE 22 95 95 2 PHOENIX.=L+30-XE2.=L+30-XE2
100 2 ST 341218 MODULE FLKMS-D37SUB/S/ZFK3DS/PE 22 95 96 5 PHOENIX.=L+30-XA2 -XANEA.=L+30-XA2 -XANEA
110 1 ST 341215 MODULE FLKMS-D15SUB/S/ZFKKDS/PE 22 95 97 8 PHOENIX.=L+30-XDEA.=L+30-XDEA
120 1 ST 102523 PLUG HOUSING 350779-1 AMP130 2 ST 102522 PIN 926894-1 AMP
222583 CONTROL TASC 200 9558-H100TASC 200
10 1 ST 222584 HOUSING 9558-U10 TASC 200 SIEMENS20 1 ST 222588 SOFTWARE TASC 200 9558-U25 TLT40 1 ST 237930 ELECTR. COMPONENTRY 9558-632 BIT-BUS-MODUL50 1 ST 225124 ELECTR. COMPONENTRY 9558-U19 CPU M17/A16 KPL.60 1 ST 237931 ELECTR. COMPONENTRY 9558-52570 1 ST 254641 ELECTR. COMPONENTRY 9558-524 PROZESS I/O80 1 ST 098417 INSULATING FOIL 140X219 69-11 7487/-800 KAHL90 1 ST 147931 LABEL 68X43mm ZTR 68X43 7813 PET SILBER ROSENBAUM
100 1 ST 237933 ELECTR. COMPONENTRY 9558-597 BASISBOARD TASC 200
924291 CONTROL TASC 200 9558-H103
Seite 19
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 LieferantTASC 200 STD. + 2. BIT-BUS-MODUL
10 1 ST 222584 HOUSING 9558-U10 TASC 200 SIEMENS20 1 ST 222588 SOFTWARE TASC 200 9558-U25 TLT40 1 ST 237930 ELECTR. COMPONENTRY 9558-632 BIT-BUS-MODUL50 1 ST 225124 ELECTR. COMPONENTRY 9558-U19 CPU M17/A16 KPL.60 1 ST 237931 ELECTR. COMPONENTRY 9558-52570 1 ST 254641 ELECTR. COMPONENTRY 9558-524 PROZESS I/O80 1 ST 098417 INSULATING FOIL 140X219 69-11 7487/-800 KAHL90 1 ST 147931 LABEL 68X43mm ZTR 68X43 7813 PET SILBER ROSENBAUM
100 1 ST 237933 ELECTR. COMPONENTRY 9558-597 BASISBOARD TASC 200110 1 ST 237929 ELECTR. COMPONENTRY 9558-5150 BIT-BUS-MODUL
924290 CONTROL TASC 200 9558-H102TASC 200 STD. + 2. E/A-KARTE
10 1 ST 222584 HOUSING 9558-U10 TASC 200 SIEMENS20 1 ST 222588 SOFTWARE TASC 200 9558-U25 TLT40 1 ST 237930 ELECTR. COMPONENTRY 9558-632 BIT-BUS-MODUL50 1 ST 225124 ELECTR. COMPONENTRY 9558-U19 CPU M17/A16 KPL.60 1 ST 237931 ELECTR. COMPONENTRY 9558-52570 1 ST 254641 ELECTR. COMPONENTRY 9558-524 PROZESS I/O80 1 ST 098417 INSULATING FOIL 140X219 69-11 7487/-800 KAHL90 1 ST 147931 LABEL 68X43mm ZTR 68X43 7813 PET SILBER ROSENBAUM
100 1 ST 237933 ELECTR. COMPONENTRY 9558-597 BASISBOARD TASC 200110 1 ST 237927 ELECTR. COMPONENTRY 9558-4036 DIG.E/A BCD-KOM.
922884 ELECTRIC EQUIPMENT 97073-575 Steuerunganschluß LASER-Kühlung
10 1 ST 143397 AUXILIARY CONTACTOR 4S 24V 3RH11 40-2BB40 SIEMENS.=L+47-K1.=L+47-CR1
20 1 ST 142946 DIODE 3RT19 16-1EH00 SIEMENS.=L+47-K1.=L+47-CR1
30 1 ST 129319 HOLDER 09 33 000 9988 MIT TRAEGERELEMEN HARTING.=L+47-X1.=L+47-X1
40 1 ST 067127 SOCKET INSERT 6pol. 09 33 006 2701 HARTING.=L+47-X1.=L+47-X1
922885 ELECTRIC EQUIPMENT 97073-576LASER-Kühlung Leistungsanschl Kühlaggreg
10 1 ST 850896 SWITCH 45-63A 3RV10 41-4JA10 SIEMENS.=L+47-Q1.=L+47-CB1
20 1 ST 146354 BUSBAR ADAPTER 8US11 11-4SM00 SIEMENS.=L+47-Q1.=L+47-CB1
922886 ELECTRIC EQUIPMENT 97073-577LASER-Kühlung LeistungsanschlußKühlturm / Plattenwärmetauscher
10 1 ST 144606 PROTECTIVE MOTOR SWITCH 22-32A 3RV10 31-4EA10 SIEMENS.=L+47-Q1.=L+47-CB1
20 1 ST 146377 BUSBAR ADAPTER 8US12 61-5FM08 SIEMENS.=L+47-Q1.=L+47-CB1
923044 ELECTRIC EQUIPMENT 97073-581KLEMMLEISTE +59-X1 (LASER-Kühlung)
10 1 ST 035064 END CLIP E/UK 12 01 44 2 PHOENIX20 1 ST 084779 STRIP WITH NAMEPLATE KLM 10 04 30 6 PHOENIX30 3 ST 046224 TERMINAL UK16 30 06 01 4 PHOENIX
13 14 1540 1 ST 035059 TOOTHED STRAP 1051003/UNBEDR. 1051003/UNBEDR.1 STREIFEN = 10 S PHOENIX50 1 ST 068736 PROT.CONDUCTOR TERMINAL USLKG16 04 43 01 0 PHOENIX
PE
922887 ELECTRIC EQUIPMENT 97073-582.=L+59-X2
10 1 ST 106604 LABEL HOLDER 209-112 WAGO20 2 ST 133685 END CLIP 249-116 WAGO30 2 ST 098313 TERMINAL 280-402 WAGO40 13 ST 106606 TERMINAL 280-633 WAGO50 2 ST 106614 PROT.CONDUCTOR TERMINAL 280-677 WAGO60 3 ST 106607 STOP PLATE 280-315 WAGO70 1 ST 106729 MARKER WGO 5/10-5 55445 MURRPLAS
922888 ELECTRIC EQUIPMENT 97073-583.=L+59-X3
10 1 ST 106604 LABEL HOLDER 209-112 WAGO
Seite 20
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant20 2 ST 133685 END CLIP 249-116 WAGO30 55 ST 106606 TERMINAL 280-633 WAGO40 8 ST 106614 PROT.CONDUCTOR TERMINAL 280-677 WAGO50 15 ST 106607 STOP PLATE 280-315 WAGO60 1 ST 106729 MARKER WGO 5/10-5 55445 MURRPLAS70 31 ST 098313 TERMINAL 280-402 WAGO80 2 ST 129325 REDUCING BRIDGE 284-414 WAGO90 9 ST 146353 TERMINAL LED DC 24V 280-658/281-434 WAGO90 10 ST 146353 TERMINAL LED DC 24V 280-658/281-434 WAGO
100 1 ST 129326 COVERING PLATE E 284-335 WAGO110 1 ST 106616 PROT.CONDUCTOR TERMINAL 281-687 WAGO120 3 ST 129321 TERMINAL 284-601 WAGO130 1 ST 129324 PROT.CONDUCTOR TERMINAL 284-607 WAGO140 1 ST 129323 CROSS BRIDGER 284-402 WAGO
922890 ELECTRIC EQUIPMENT 97073-592SCHNITTSTEL. MASCHINENANSCHLUSS
10 1 ST 120547 HOLDER 09 33 000 9989 MIT TRAEGERELEMEN HARTING.=L+60-X50.=L+60-X50
20 1 ST 069468 SOCKET INSERT 09 21 040 3101 HARTING.=L+60-X50.=L+60-X50
30 35 ST 069252 CRIMP CONTACT 09 15 000 6203 HARTING.=L+60-X50.=L+60-X50
40 1 ST 341216 MODULE FLKMS-D25SUB/B-ZFK3DS/PE 22 95 93 6 PHOENIX.=L+60-X55.=L+60-X55
50 1 ST 120547 HOLDER 09 33 000 9989 MIT TRAEGERELEMEN HARTING.=L+60-X3.=L+60-X3
60 1 ST 062157 SOCKET INSERT 16pol. 09 33 016 2701 HARTING.=L+60-X3.=L+60-X3
955581 ELECTRIC EQUIPMENT 97073-591SCHNITTSTEL. MASCHINENANSCHLUSSOHNE HAUPSCHALTER
10 1 ST 120547 HOLDER 09 33 000 9989 MIT TRAEGERELEMEN HARTING.=L+60-X50.=L+60-X50
20 1 ST 069468 SOCKET INSERT 09 21 040 3101 HARTING.=L+60-X50.=L+60-X50
30 35 ST 069252 CRIMP CONTACT 09 15 000 6203 HARTING.=L+60-X50.=L+60-X50
40 1 ST 341216 MODULE FLKMS-D25SUB/B-ZFK3DS/PE 22 95 93 6 PHOENIX.=L+60-X55.=L+60-X55
50 1 ST 120547 HOLDER 09 33 000 9989 MIT TRAEGERELEMEN HARTING.=L+60-X3.=L+60-X3
61 1 ST 062156 PLUG INSERT 16pol. 09 33 016 2601 HARTING.=L+60-X3.=L+60-X3
922889 ELECTRIC EQUIPMENT 97073-588MASCHINENANSCHLUSS LEISTUNGSTEIL
10 1 ST 923045 ELECTRIC EQUIPMENT 97073-584 KLEMMLEISTE +60-X41.220 1 ST 850896 SWITCH 45-63A 3RV10 41-4JA10 SIEMENS
.=L+60-Q1
.=L+60-CB130 1 ST 146354 BUSBAR ADAPTER 8US11 11-4SM00 SIEMENS
.=L+60-Q1
.=L+60-CB1
922891 ELECTRIC EQUIPMENT 97073-593SCHNITTSTELLE MASCHINENANSCHLUSS BCD
10 1 ST 120547 HOLDER 09 33 000 9989 MIT TRAEGERELEMEN HARTING.=L+60-X9.=L+60-X9
20 1 ST 069468 SOCKET INSERT 09 21 040 3101 HARTING.=L+60-X9.=L+60-X9
30 35 ST 069252 CRIMP CONTACT 09 15 000 6203 HARTING.=L+60-X9.=L+60-X9
40 1 ST 341217 MODULE FLKMS-D37SUB/B/ZFK3DS/PE 22 95 95 2 PHOENIX.=L+30-XE3.=L+30-XE3
Seite 21
Schaltplanstückliste 97073-5-202_08.xls
Pos. Menge ME Ident.Nr. Bezeichnung 1 Bezeichnung 2 Lieferant50 1 ST 341218 MODULE FLKMS-D37SUB/S/ZFK3DS/PE 22 95 96 5 PHOENIX
.=L+30-XA3
.=L+30-XA360 2 ST 220599 CABLE 9704-11879 DIGITAL E/A 37-POLIG TLT
.=L+30-XE3 -XA3
.=L+30-XE3 -XA370 2 ST 096770 PLUG PART 17 57 01 9 MSTB2,5/2-ST-5,08 PHOENIX
.=L+30-XE3 -XA3
.=L+30-XE3 -XA3
Seite 22
BEL Versorgungseinheit TLF1800t bis TLF4000t.xlw 9707-576-10 Englisch 28.03.2000
labeldatas version 00gas- and vakuumunit date 20.07.1999
id.nr. 917234 by 533zdrw. nr. 9707-576-10
components and labellistpc=purchasedmf=manufactured
Functiontext cable pc cable mf cabledefination cablelabel cable component componentdefination componentlabelIdent.Nr.: Ident.Nr.: source destination Ident. Nr.: Length/mm Ident. Nr.: electr. mech. Ident. Nr.:
vacuum pump - 900520 +17-X1 +17-M1 143087 3000 117795 +17-M1 143090actual value system pressure - 900381 +17-X4 +17-B1 143088 3000 132132 +17-B1 143090ground - 900527 3000cable actuator sensor interface 139423 900512 +59-X11 +59-ASI1 143087 3000 143090fan - 903171 +59-X2 +17-E2 143087 3000 088952 +17-E2
vacuum on - +59-ASI1.1A +17-Y1 143088 1000 141259 +17-Y1 143090fill gas accumulator - +59-ASI1.1B +17-Y8 143088 1000 116890 +17-Y8 143090gas mix slow - +59-ASI1.2A +17-Y2 143088 1000 116890 +17-Y2 143090gas mix fast - +59-ASI1.2B +17-Y3 143088 1000 116890 +17-Y3 143090pump out slow - +59-ASI1.3A +17-Y4 143088 1000 135349 +17-Y4 143090pump out fast - +59-ASI1.3B +17-Y5 143088 1000 135349 +17-Y5 143090pump out gear chamber fast - +59-ASI1.4A +17-Y6 143088 1000 135349 +17-Y6 143090vacuum system open - +59-ASI1.4B +17-Y7 143088 1000 141259 +17-Y7 143090fill gas accumulator - 259371 +59-ASI1.5A +17-S1 143088 1000 +17-Y8 143090gas pressure N2 >4000hPa 129115 249674 +59-ASI1.5B +17-S2 143088 900 116885/116886 +17-S1 143090gas pressure CO2 >4000hPa 129115 249674 +59-ASI1.6A +17-S3 143088 900 116885/116886 +17-S2 143090gas pressure HE >4000hPa 129115 249674 +59-ASI1.6B +17-S4 143088 900 116885/116886 +17-S3 143090system pressure <1100hPa 130943 250370 +59-ASI1.7 +17-S5 143088 500 140746 +17-S4 143090
actuator sensor interface 128335 +59-ASI1 143090
135993
135993
135993
135993
533z / 358t 1 von 1
BEL_Resonator_TLF1500_3800t (97073-610-4_00).xls Englisch 27.07.2000
labeldatas version 00
962759 date 000727-FEATH
drw.nr. 97073-610-4 by 533FEATH
resonator TLF1500....3800 turbo components and labellist
pc=purchasedmf=manufactured
function cable pc cable mf cabledefination cablelabel cable component componentdefination componentlabelIdent.Nr.: Ident.Nr.: source destination Ident. Nr.: Length/mm Ident. Nr.: electr. mech. Ident. Nr.:
valve shutter open - 900197 =L+59-X6 =L+19-Y1 143088 1500 094457 =L+19-Y1 143090valve beam tube ventilation - 245482 =L+59-X6 =L+19-Y5 143088 2000 =L+19-Y5 143090shutter closed - 900192 =L+59-X6 =L+19-S2 143088 1400 =L+19-S2 143090excess temp. at shutter - 900193 =L+59-X6 =L+19-S3 143088 1400 =L+19-S3 143090shutter open =L+59-X6 =L+19-B2 143088 1400 050924 =L+19-B2 143090air pressure shutter present - 925146 =L+59-X6 =L+19-S8 143088 1600 058092 =L+19-S8 143090intignition booster =L+59-X6 =L+19-A2 143088 1400 =L+19-A2 143090
# laser diode =L+59-X6 =L+19-A1 143088 1600 146317 =L+19-A1 143090# shutter open (laser diode) =L+59-X6 =L+19-S7 143088 1600 080349 =L+19-S7 143090
# valve Al-circulation at central cooling system =L+59-X6 =L+19-Y6 143088 2000 =L+19-Y6 143090# valve Cu-circulation at central cooling system =L+59-X6 =L+19-Y7 143088 2000 =L+19-Y7 143090
telescope cover - 922748 =L+59-X6 =L+22-S8 143088 1600 =L+22-S8 143090
beam tube check from external =L+59-X6 =L+22-S9 143088 2000 =L+22-S9 143090
RF-cover - 922745 =L+59-X6 =L+22-S1 143088 1600 056737 =L+22-S1 143090
2x earth-wire resonator cover 6qmm - 239910
resonator type 44000cooling water flow sensor Al - 245477 =L+59-X6 =L+19-S6 143088 1100 125993/067457 =L+19-S6 143090
resonator type 44001cooling water flow sensor Al =L+59-X6 =L+19-S5 143088 1100 125993 =L+19-S5 143090cooling water flow sensor Cu - 245477 =L+59-X6 =L+19-S6 143088 1100 125993/067457 =L+19-S6 143090
# = Option Seite 1 von 2 533FEATH
BEL_Resonator_TLF1500_3800t (97073-610-4_00).xls Englisch 27.07.2000
labeldatas version 00
962759 date 000727-FEATH
drw.nr. 97073-610-4 by 533FEATH
resonator TLF1500....3800 turbo components and labellist
pc=purchasedmf=manufactured
function cable pc cable mf cabledefination cablelabel cable component componentdefination componentlabelIdent.Nr.: Ident.Nr.: source destination Ident. Nr.: Length/mm Ident. Nr.: electr. mech. Ident. Nr.:
standard stup LSMpower input blower 1 (LSM) 149965 - =L+5-X1 =L+5-M1:X1.1 10500 =L+5-M1:X1.1 143090pilot circuit field regulator bearings 1 149966 - =L+5-A2:X3 =L+5-M1:X3.1 12000 =L+5-M1:X3.1 =L+5-M1 143090pilot circuit field regulator sensors 1 149967 - =L+5-A2:X4 =L+5-M1:X4.1 12000 =L+5-M1:X4.1 143090
feeder line terminal box resonator - 900189 =L+59-X5 =L+59-X6 143087 9500actual value laser power - 941908 =L+19-X1 =L+19-B1 143088 10000 132736/126924 =L+19-B1 143090
earth-wire resonator 25qmm - 233575 PE busbar resonator 143088 10200 143090
setup LSM 5m longerpower input blower 1 (LSM) 341105 - =L+5-X1 =L+5-M1:X1.1 16500 =L+5-M1:X1.1 143090pilot circuit field regulator bearings 1 341106 - =L+5-A2:X3 =L+5-M1:X3.1 16500 =L+5-M1:X3.1 =L+5-M1 143090pilot circuit field regulator sensors 1 341107 - =L+5-A2:X4 =L+5-M1:X4.1 16500 =L+5-M1:X4.1 143090
feeder line terminal box resonator - 925761 =L+59-X5 =L+59-X6 143087 16000actual value laser power TLF5000.....12000 - 941909 =L+19-X1 =L+19-B1 143088 16000 132736/126924 =L+19-B1 143090
earth-wire resonator 25qmm - 927062 PE busbar resonator 143088 16000
standard stup TRGpower input blower 1 (TRG) =L+5-X1 =L+5-M1:X1.1 143087 10500 =L+5-M1:X1.1 143090cold conduktor connection turbine 1 =L+5-X1 =L+5-R1 143088 10500 =L+5-R1
feeder line terminal box resonator - 900189 =L+59-X5 =L+59-X6 143087 9500actual value laser power - 941908 =L+19-X1 =L+19-B1 143088 10000 132736/126924 =L+19-B1 143090
earth-wire resonator 25qmm - 233575 PE busbar resonator 143088 10200 143090
setup TRG 5m longerpower input blower 1 (TRG) =L+5-X1 =L+5-M1:X1.1 143087 16500 =L+5-M1:X1.1 143090cold conduktor connection turbine 1 =L+5-X1 =L+5-R1 143088 16500 =L+5-R1
feeder line terminal box resonator - 925761 =L+59-X5 =L+59-X6 143087 16000actual value laser power TLF5000.....12000 - 941909 =L+19-X1 =L+19-B1 143088 16000 132736/126924 =L+19-B1 143090
earth-wire resonator 25qmm - 927062 PE busbar resonator 143088 16000
928711
928710
# = Option Seite 2 von 2 533FEATH
Versorgungseinheit (supplymodule) TLF 1500t-3800t
TRUMPF
+17-E2
Z.nr. (drw.nr.)
Name
Blatt / pageÄnderungsnr./modificationnr.
Id.nr.
9707-576-10917234
991008-533le08.10.99 / 01 TLF 3 000.CDR
1 / 1 ..Datum/Index(date/version)
+17-M1(-MTR1)
+17-Y3(-SOL3)
+17-Y2(-SOL2)
+17-Y4(-SOL4)
+17-Y7(-SOL7)
+17-B1
+17-X4.1
+17-S5 (-PS5)
+17-Y5(-SOL5)
+17-Y6(-SOL6)+17-Y1
(-SOL1)+17-Y8 (-SOL8)
+17-S3 (-PS3)
+17-S2 (-PS2)
+17-S4(-PS4)