Enclosure TEFC, TEAAC, TEWAC, ODP, WPI, WPII
Rating 373 - 14,900 kW (500 - 20,000 hp)
Voltage
Low Voltage ( 400 - 690 VAC)
Medium voltage (to 6,900 VAC)
High voltage (to 13.2 kVAC)
Frequency 50 and 60 Hz
Mounting Vertical and Horizontal Mounting
Standards NEMA, CSA, BS, ANSI, API 541, API 547
Certifications UL, CSA, hazardous area, ABS (marine)
Enclosure TENV, TEFC, ODP
RatingTENV & TEFC - 0.09 - 1,100 kW (0.12 - 1,500 hp)
ODP 0.18 - 1,100 kW (0.25 - 1,500 hp)
Voltage 200, 230/360, 380, 400, 460, 575 VAC
Frequency 50, 60 and 50/60 Hz available
Mounting Standard, C-face - with and without base, D-flange
Enclosure TENV, TEFC, ODP
RatingTENV & TEFC 0.06 - 11 kW (0.08 - 15 hp)
ODP 0.12 - 7.5 kW (0.17 - 10 hp)
Voltage 110/220 VAC
Frequency 50, 60 and 50/60 Hz available
Mounting Standard, C-face - with and without base, D-flange
With expertise, and a comprehensive portfolio of products and life-cycle services, we help value-minded industrial customers improve their energy efficiency and productivity.
2 ABB | Motors and Generators | Baldor•Reliance NEMA motors product overview
Large AC induction motors
General purpose - three phase motors
General purpose - single phase motors
Enclosure TENV, TEFC
Rating 0.18 - 15 kW (0.25 - 20 hp)
Voltage 200, 230/460, 380, 460, 575 VAC
Frequency 50, 60 and 50/60 Hz available
Mounting Standard, C-face - with and without base
Designs White washdown, paint-free, stainless and SSE encapsulated
stainless, feather picker motors
Enclosure TENV, TEFC
Rating 0.18 - 600 kW (0.25 - 800 hp)
Voltage 115/230, 200, 230/460, 380 460, 575 VAC
Frequency 50, 60 and 50/60 Hz available
Mounting Standard, C-face - with and without base, D-flange
Service Factor 1.0, 1.15 S.F.
Certifications Zone 1, Division 2, Class I & Class II
ATEX and IEC Ex available
Enclosure TENV, TEFC
Rating 0.37 - 2,250 kW (0.5 - 3,000 hp)
Voltage200, 230/460, 380, 460, 575, 690, 2,300, 3,300, 4,000, 6,600,
11,500 VAC
Frequency 50, 60 and 50/60 Hz available
Mounting Standard, C-face - with and without base, D-flange
Certifications Division 2, Class I, Groups A, B, C & D Inverter Duty on Severe Duty
and IEEE841 motors
Designs
NEMA design A & B Severe Duty motors
IP55
IEEE841-2009
Dirty duty; crusher and quarry duty high torque design motors
Design D (High Slip) oil field pump motors
Baldor•Reliance NEMA motorsProduct overview
ABB | Motors and Generators | Baldor•Reliance NEMA motors product overview 3
Washdown duty motors
Explosion proof motors
Severe duty motors
Enclosure TEAO
Rating 5.5 - 220 kW (7.5 - 350 hp)
Voltage Custom voltage available (200 - 690 VAC)
Speed 90 - 650 RPM
Mounting Direct drive, eliminating CT gearbox
Designs Requires ABB ACS880+N5350 drive
High efficiency interior permanent magnet design
Enclosure TENV, TEFC, ODP, TEAO
Rating
TENV & TEFC 0.75 - 37 kW (1 - 50 hp)
ODP 0.75 - 75 kW (1 - 100 hp)
TEAO 2.2 - 75 kW (3 - 100 hp)
Voltage 115/230, 200, 230/460, 380, 460, 575 VAC
Frequency 50, 60 and 50/60 Hz available
Mounting Standard, Resilient mount
Designs Shaft grounding for use with adjustable speed drives
Enclosure TEFC, ODP
RatingTEFC 0.75 - 37 kW (1 - 50 hp)
ODP 0.75 - 56 kW (1 - 75 hp)
Voltage 115/230, 200, 230/460, 380, 460, 575, 2,300/4,000 VAC
Frequency 50 Hz and 50/60 Hz available
Mounting JM, JP and West Coast mounting, SAE hydraulic pump
Designs
Jet pump 56J through 2.2 kW (3 hp)
Submersible 0.75 - 335 kW (1-450 hp)
Immersible 3.7 - 186 kW (5 - 250 hp)
Vertical solid shaft, low, medium, and high thrust
API 610 up to 670 kW (900 hp)
Baldor•Reliance NEMA motorsProduct overview
4 ABB | Motors and Generators | Baldor•Reliance NEMA motors product overview
Direct drive cooling tower motor
HVAC motors
Pump motors
Enclosure TEFC, ODP
RatingTEFC 0.18 - 22 kW (0.25 - 30 hp)
ODP 0.37 - 11 kW (0.5 - 15 hp)
Voltage 115/230, 200, 230/460, 380, 460, 575 VAC
Frequency 50, 60 and 50/60 Hz available
Brake Rating 4 - 1,360 Nm (3 - 1,000 lb-ft)
Designs Explosion proof and washdown motors
Enclosure TEFC
Rating 0.37 - 5.5 kW (0.5 - 7.5 hp)
Voltage 115/230, 200, 230/460, 460, 575 VAC
Frequency 50, 60 and 50/60 Hz available
Mounting Standard, C-Face – with or without base, D-flange
Enclosure TEFC, ODP
RatingTwo-speed motors 0.35 - 187 kW (0.5 - 250 hp)
Pressure washer motors 1.1 - 3.7 kW (1.5 - 5 hp)
Frequency 50 Hz and 50/60 Hz available
Designs Arbor saw, woodworking, pre-1952-NEMA, U-frame,
automotive duty, synchronous permanent magnet motors
Stator and rotor sets, partial motors
Baldor•Reliance NEMA motorsProduct overview
ABB | Motors and Generators | Baldor•Reliance NEMA motors product overview 5
Brake motors
Unit handling and conveyor motors
Definite purpose motors
Enclosure TENV, TEFC
Rating 0.015 - 3.7 kW (0.02 - 5 hp)
Voltage 12, 24, 90, 180 VDC
MountingNEMA or IEC mounting available
C-face with base, rigid base
Designs General purpose, integral tachometer, explosion proof, washdown,
stock and custom designs
Enclosure TENV, TEFC, TEBC, DPFV
Rating
TENV 1.5 - 75 kW (2 - 100 hp)
TEFC 5.6 - 150 kW (7.5 - 200 hp)
TEBC 3.7 - 372 kW (5 - 500 hp)
DPFV 3.7 - 745 kW (5 - 1,200 hp)
Voltage 230, 380, 400, 415, 460, 575, up to 1,000 VAC
Frequency Variable frequency has to be run with a drive
Feedback With or without encoder or tach
Designs Custom NEMA and IEC motors available
Induction 1000:1 or Interior permanent magnet, constant torque
Enclosure TENV, TEBC & TEFC
Rating 0.25 - 1,120 kW (0.33 - 1,500 hp)
Voltage 230/460, 575 VAC
Frequency Inverter/Vector - 50/60 hz, VS Master has to be run with a drive
Feedback With or without encoder or tach
Designs Washdown, explosion proof, inverter duty motors
1000:1 constant torque
Baldor•Reliance NEMA motorsProduct overview
6 ABB | Motors and Generators | Baldor•Reliance NEMA motors product overview
DC motors - Permanent magnet
Inverter / vector motors
Inverter / vector motors
Enclosure TENV, TEFC
Gearhead Type Right Angle & Parallel Shaft
Power Supply AC, DC
VoltageAC 208-230/460 VAC
DC 12, 24, 90, 180 VDC
Feedback With or without encoder or tach
Designs Washdown, and Inverter Duty
Mounting C-face, D-flange kits, double C-face brake kits
Bases Adjustable motor bases and conversion bases
(T-frame to U-frame)
Housing Fan housing, drip covers, conduit box kits
Mod-Express Menden, Germany Build Center
Fort Smith, Arkansas
Gainesville, Georgia
Fractional
Enclosure TENV, TEFC
Rating 0.18 - 0.746 kW (0.25 - 1 hp)
Voltage 90, 180 VDC for 1 Ph control
Mounting NEMA C-Face with base, rigid base
Designs General purpose, explosion proof
Integral
Enclosure DPFG, DPBV, TENV, TEFC, TEDC,
Rating0.746 kW - 2238 kW (1 - 3,000 hp)
27-1,300 kW (35 - 1,750 hp) IEC laminated frame
Voltage 90, 180 VDC for 1 Ph control, 240, 500, 700 VDC for 3 Ph control
Mounting NEMA or IEC available
Designs General purpose, explosion proof, round frame, laminated steel frame
Baldor•Reliance NEMA motorsProduct overview
ABB | Motors and Generators | Baldor•Reliance NEMA motors product overview 7
Gearmotors
Motor accessories & NEMA motor Mod-Express
DC motors - wound field
Contact us
www.abb.com/motors&generators We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB Ltd does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.
We reserve all rights in this document and in the subject matter and illustrations contained herein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in part - is forbidden without prior written consent of ABB Ltd.
© Copyright 2012 ABB. All rights reserved. Specifications subject to change without notice.
9AK
K10
6370
EN
12-
2014