178
A
L __ _ 01295
t
A
4208DL-36CO
Lifting Cable
Lifting Detail Lifting Lug
6
PLAN VIEW SCALE 1:30
� -- - --1295� -- - - -�
SECTION A-A SCALE 1:30
1
r100
Gasket (by others)--�, External Mastic Wrap
(Recommended, by others)
64
TONGUE & GROOVE DETAIL SCALE 1: 15
Mastic (by others
SUGGESTED JOINT DETAIL SCALE 1: 15
Specification and General Notes:
1. Manhole design/manufacture to ASTM C478M Specification. 2. Concrete testing to current version of ASTM C497/CSA 23.1&2. 3. Min. concrete compressive strength 30 MPa with Max. W/C ratio of 0.5 4. Gasket to ASTM C-443 specification (by others). 5. Concrete cover to be Min.25mm. 6. All dimensions to be millimeter. 7. Welded wire mesh overlap to be 300mm. 8. Manhole design and construction to MMCD manhole specification section 02725. 9. Manufacturing tolerance to be+/- 5mm. 10. Concrete Exposesure Class to be A-3 11. Min. Stripping Strength to be 15MPa 12. All Form Finish to be Standard Grade 13. All Unformed Finish to be Steel Trowelled Finish or Wood Float Finish 14. Lifting cable and accessaries to meet the strength requirement in lifting detail 15. Hoisting and Rigging system to meet WORK SAFE BC OHS Regulation Guideline Part 14/15
Description:
DI �MOND 1067 ID DONUT LID-914 OPENING
__ :¥,RECAST CONCRETE42 Donut Lid 786#-36" OPENING
Project:
7520 Conrad Street Burnaby, B.C. V5A 2H7 Phone : 604-415-5181 Fax : 604-415-5185
www.diamondprecast.com
REINFORCEMENT PLAN VIEW SCALE 1:30
Drawn : Date :
D.L 24/09/2016
Aproved : Load Rating:
v.w. H20 RATED
Rev. No. Scale : A As Shown
01245
catalog No.
4208DL
-36CO
Dwg. No.
42-14
This drawing is the proper.ty of the Sheet No. i amond Precast Concrete. All inform ation contained herein is confidential and may 1 OF 1 no
�������:����� g;ert;,��
ut
REV.C
01295
A
PLAN VIEW SCALE 1:30
6 1 REV.C
100
2 4
1295
SECTION A-A SCALE 1:30
A
REV.C
t
Lifting Detail
25
4208DL
Lifting Lu
REV.C
Lifting Cable
�1195
Gasket (by others)--�,
External Mastic Wrap (Recommended, by others)
64
TONGUE & GROOVE DETAIL SCALE 1: 15
Mastic (by others
SUGGESTED JOINT DETAIL
SCALE 1: 15
Specification and General Notes: REV.B
1. Manhole desi n manufacture to ASTM C478M S ification. . ncrete testing to current version o . .
3. Min. concrete compressive strength 30 MPa with Max. W/C ratio of 0.5 4. Gasket to ASTM C-443 specification (by others). 5. Concrete cover to be Min.25mm. 6. All dimensions to be millimeter. 7. Welded wire mesh overlap to be 300mm. 8. Manhole design and construction to MMCD manhole specification section 02725. 9. Manufacturing tolerance to be+/- 5mm. 10. Conaete Exposesure Class to be A-3 11. Min. Stripping Strength to be 15MPa 12. All Form Finish to be Standard Grade 13. All Unformed Finish to be Steel Trowelled Finish or Wood Float Finish 14. Lifting cable and accessaries to meet the strength requirement in lifting detail 15. Hoisting and Rigging system to meet WORK SAFE BC OHS Regulation Guideline Part 14/15
DI �MOND __ :¥,RECAST CONCRETE
Desaiption:
1067 ID DONUT LID
42 Donut Lid 786#
Project:
7520 Conrad Street Burnaby, B.C. V5A 2H7 Phone : 604-415-5181
www.diamondprecast.com
Fax : 604-415-5185
REINFORCEMENT PLAN VIEW SCALE 1:30
Drawn : Date :
D.L 07/03/2016
Aproved : Load Rating:
v.w. H20 RATED
Rev. No. Scale : C As Shown
catalog No.
4208DL
Dwg. No.
42-08
This drawing is the proper.ty of the Sheet No. i amond Precast Concrete. All inform ation contained herein is confidential and may 1 OF 1 no
�������:����� g;ert;,��
ut
A
5
---
I ---------
/ "" / "'
;(9 2
/ I
I
I
\
\
PLAN I VIEW SCALE 1:30
SECTION A-ASCALE 1:30
01295 OD
REV.C 3
1001 2
Gasket (by others)--�, External Mastic
(Recommended,
64
TONGUE & GROOVE DETAILSCALE 1: 15
Mastic (by others
SUGGESTED JOINT DETAILSCALE 1: 15
Specification and General Notes: REV.B
1. Manhole desi n manufacture to ASTM C478M S ification. . ncrete testing to current version o . .
3. Min. concrete compressive strength 30 MPa with Max. W/C ratio of 0.5 4. Gasket to ASTM C-443 specification (by others). 5. Concrete cover to be Min.25mm. 6. All dimensions to be millimeter. 7. Welded wire mesh overlap to be 300mm. 8. Manhole design and construction to MMCD manhole specification section 02725. 9. Manufacturing tolerance to be+/- 5mm. 10. Conaete Exposesure Class to be A-3 11. Min. Stripping Strength to be 15MPa 12. All Form Finish to be Standard Grade 13. All Unformed Finish to be Steel Trowelled Finish or Wood Float Finish 14. Lifting cable and accessaries to meet the strength requirement in lifting detail 15. Hoisting and Rigging system to meet WORK SAFE BC OHS Regulation Guideline Part 14/15
DI �MOND __ :¥,RECAST CONCRETE
Description:
1067 ID Donut Lid Hatch Opening
42 Donut Lid Hatch Opening 600 #
Project:
t 4208DLH
Lifting cable
Lifting Lug
Lifting Detail
REV.C
912 X 608 OPENING
BOTTOM REINFORCEMENT PLAN VIEWSCALE 1:30
Drawn: Date: catalog No.
D.L 31/03/2016 4208DLH
Aproved: Load Rating:
v.w. H20 RATED Dwg. No.
Rev. No. Scale: 42-09C As Shown
7520 Conrad Street Burnaby, B.C. V5A 2H7 Phone : 604-415-5181 Fax : 604-415-5185 This drawing is the proper.ty of the Sheet No.
iamond Precast Concrete. All information
www.diamondprecast.com contained herein is confidential and may 1 OF 1 no�������:����� g;ert;,��
ut