+ All Categories
Transcript
Page 1: A Shunt trip disconnect designed as a simple economic solution … · 2019. 12. 13. · Computer Room Shunt Trip. Authorized Distributor •Fuseco Inc. •Pricing & Availability:

STANDARD FEATURES & BENEFITS• 3PhaseFusedPowerSwitch• ShuntTrip120V• GroundLugPerNEC• KeytoTestSwitch-120VwithLegendPlate• FireSafetyInterfaceRelay• FireAlarmVoltageMonitoringRelay• ControlPowerTransformerwithFuseandBlocks• MechanicallyInterlockedAuxiliaryContacts• PilotLight-120VClearLED*(Coloroptionavailable)• PadlockableHandleforServiceWorkSafety

OPTIONAL FEATURES• Nema3,4,12&4XEnclosures• PilotLightsavailableinRed,GreenorWhite• IsolatedNeutralLug,100or200Amp

• Typical Applications:• ElevatorDisconnect• BuildingEmergencySystems• ComputerRoomShuntTrip

Authorized Distributor•Fuseco Inc.

•Pricing & Availability: 1-800-234-3873•Technical Services: 918-665-6888

UL 508A ASSEMBLY USING EATON PRODUCTS

A Shunt trip disconnect designed as a simpleeconomic solution that complies with code requirements

Page 2: A Shunt trip disconnect designed as a simple economic solution … · 2019. 12. 13. · Computer Room Shunt Trip. Authorized Distributor •Fuseco Inc. •Pricing & Availability:

RATINGS:VOLTS:AMPS:

600AC30A, 60A,100A, 200A & 400A

APPROVALS:• UL98EnclosedMoldedCaseSwitch• UL50Enclosure• UL/cULListedControlPanel

RECOMMENDED FUSE USAGESTSSeries...usewithAJT,A4J,HSJ

Authorized Distributor•Fuseco Inc.•Pricing & Availability: 1-800-234-3873•Technical Services: 918-665-6888• www.nema7.com

FUSIBLE SHUNT TRIP UL508AASSEMBLYUSINGEATONPRODUCTS

*100VAwithprimaryfusing(120vsecondary)

**Combinationofcontactsandalarmswitch.“A”isasetofcontactsmechanicallytothemainswitch.Thesecontactsareusedtoenableordisable

theBatteryLoweringDeviceformaintenanceperNFPAcode.The“B”contactsaretwosetsofauxiliarycontacts(doublepole,doublethrow)thatare

alsomechanicallyinterlockedtothemainswitchandaregenerallyusedtomonitorthestatusoftheswitch.Contactlogicisshownbelow.

***ForuseonlywithR1option(doublepole,doublethrow)

NO NC NO NCClosedTrippedOpen

"A" & "B" Contact Logic"A" Contacts "B" ContactsMain Switch

OCC

CCO

OOC

CCO

STS 1 R1 K W N1 X

120 VAC

24 VDC

120 V K RED

GREEN

WHITE

30-60A 1 NO & 1 NC

2 NO & 2 NC

"X"

BOTH SETS

1 POLE NEMA 3R

NEMA 4

NEMA 12

STS 3

STS 6

STS 1

STS 2

208V

240V

480V

600V

100A 3 POLE

200A

30 A

60 A

100 A

200 A

T20

T24

T48

T60

R1

R2

R

G

W

N6

N1

N2

F1

F3***

U

Y

Z

ISOLATED NEUTRAL LUG

AUX CONTACTS STD "A" & "B"OPTIONS AREINCLUDED **

FIRE ALARM VOLTAGE

MONITORINGRELAY

ENCLOSURE OPTIONSNEMA 1

STANDARD

NEMA7 SWITCHCATALOG

NUMBER

CONTROLPOWER

TRANSFORMER100 VA*

FIRE SAFETYRELAY - 3PDT

10A

KEY TO TESTSWITCH

PILOT LIGHT"ON"

CATA

LOG

AMP

RATI

NG

RATI

NG

OPT

ION

CODE

RATI

NG

OPT

ION

CO

DE

RATI

NG

OPT

ION

CO

DE

RATI

NG

OPT

ION

CO

DE

RATI

NG

OPT

ION

CO

DEO

PTIO

N

CODE

RATI

NG

RATI

NG

OPT

ION

CO

DE

RATI

NG

OPT

ION

CO

DE

STS 4 400 A

DRAWING REFLECTS 30 – 100 AMP ENCLOSURES ONLY