8/13/2019 AC Spec Selector EnRetrotec US3212 US 3212 Blower Door Air Leakage Test Systemergy SP500
1/8
Choose the perfect system from our wide range
SP500 rev-2012-08-29
Air Leakage TestSystems Selector
DU200: Total duct testingsolution.
1000: Residential testsystem with 10 year warranty.
Q4E: Fast, automatic systemfor large houses and smallcommercial buildings.
Q5E: Modular, hard panel systemfor fast, professional testing
QMG: Folding hard panelwith 3 high output fans
for testing large buildings.
actoolsupply.com
actoolsupply.com
actoolsupply.com
Retrotec US3212 Blower Door System Retrotec US3211 Blower Door System
http://www.aikencolon.com/retrotec-us3212-blower-door-air-leakage-test-systemhttp://www.aikencolon.com/retrotec-us3212-blower-door-air-leakage-test-systemhttp://www.aikencolon.com/retrotec-us3211-blower-door-air-leakage-test-systemhttp://www.aikencolon.com/http://www.aikencolon.com/Retrotec-Blower-Door-Systems_c_1074.htmlhttp://www.aikencolon.com/retrotec-us3212-blower-door-air-leakage-test-systemhttp://www.aikencolon.com/retrotec-us3211-blower-door-air-leakage-test-system8/13/2019 AC Spec Selector EnRetrotec US3212 US 3212 Blower Door Air Leakage Test Systemergy SP500
2/8
Digital Gauge Fan Performance Door Panels
Fan Control
Page 2 of 8
DM-2 mkII Digital GaugeThe DM-2 mkII is more than just adigital gauge. It is the advancedcontrol center at the heart of everyRetrotec system. It has everyimaginable feature needed to maketesting faster, easier, andmore accurate, without theneed for a computer yetcan be set up toremove allunnecessarycomplexities.
Automatic speed controlSet to any percent speed and Jog upor down in 1% or 5% increments.
Cruise ControlSet any pressure, and then Jog upor down in 5 Pa increments for fastmultipoint tests.
... or super fast!
...now use the @ key toimmediately extrapolateto the exact pressure selected by theJog key, in order to acquire a set oftest points as fast as they can bewritten down.
Laptop controlAdvanced USB connection to any
laptop allows forthe use of a wide
variety of software.
200 duct & tight house fanThis 10 inch (30 cm) fan features anaccurate ow nozzle that is unaf -fected by back pressure, or beingattached to a Flex Duct. Test ducts,tight houses, and enclosures in eitherdirection without changing the set up.
2350 residential fanThis 24 inch (60 cm) fan is ideallysuited for testing most houses andsome small commercial andindustrial buildings.
3300SR large building fanThis Retrotec exclusive fan is superpowerful and super stable. Its customindustrial strength motor is designedfor continuous operation and willnever over-heat.
The 3300 SR fans are "Self Refer-enced", making them the ideal build-ing science tool since they cannotbe hooked up incorrectly and alwaysreference the ow properly evenwhen attaching a Flex Duct to createthe worlds largest duct tester, orwhen performing oor-at-a-time highrise building tests.
Three-Fan Panel for large buildingsMaximize air ow through onedoorway with a folding 3-fan panelthat can be carried under the arm.Set up in minutes. Use the includedblanking panels if only one or twofans are needed.
Modular Panelfor exibilityRetrotecs uniquehard panels t thewidest variety ofdoorways. They arelightweight, quickand easy to set up,and provide animpressiveprofessionalappearance.
Cloth Panelfor economyOur StandardAluminum Framewith Cloth Panel will
t any residential
doorway. Ergonomicknobs, sturdy camlevers, andnumbered framepieces make thisframe easy to use.
Control from a distanceThe standard gauge-to-fan cable is20, but 70 and 250 extensionsallow control from any distance.
actoolsupply.com
actoolsupply.com
8/13/2019 AC Spec Selector EnRetrotec US3212 US 3212 Blower Door Air Leakage Test Systemergy SP500
3/8
Digital Gauge
DM-2 Digital Gauge Dimensions
Weight 14oz/397g
Size 8.75 x 4.25 x 3 in22.2 x 10.8 x 7.6 cm
Power AC adapter4 NiMH AA rechargeable batteries
Accuracy + 1 %
[Mode] Units Available
Pressure: Pascals, inches, water column, psf PrB 53.5 PaFlow: cfm, L/s, m/s, m/h Flow 253.5 cfm
Flow per area: CFM/ft, L/s/m, CFM/100ft, m/h/m, cfm/1000ft 0.25Leakage Area: EqLA (Canadian) and/or EfLA (US): cm, in, ft EqLA 12.8
EqLA and EfLA per area: in/100ft, cm/m, in/in 1.15Air changes per hour according to volume entered: /h 2.7Hole Flow: CFM, L/s, m/s, m/h 103.7 cfm
Flow/ Area
/hAirChg
HoleFlow
EqLA/ Area
Page 3 of 8
The Retrotec DM-2 displays every possible result with manual and fully automatic (or computerized) fan speed control.
Connect to FanTestic PC software viaUSB for data acquisition, automaticcontrol, or data monitoring.
Match tube to same color port.
Use an unlimitedlength of ethernetstyle Speed ControlCable to control fan. Recharge
batteries.
[Set Pressure]Control to any pressure.
[Volume Area]For Air Changes and ELA per area.
[Set Speed]Set to any % speed.
[@ Pressure]Immediate results estimatedat any test pressure.
[Jog/ Hold ]Adjust up/down in 5 Pa incrementsfor multi-point tests.
[Setup]Add/remove modes and devices.
actoolsupply.com
actoolsupply.com
8/13/2019 AC Spec Selector EnRetrotec US3212 US 3212 Blower Door Air Leakage Test Systemergy SP500
4/8
Model 200 fanLow- ow
Dimensions:Weight:
Power in:Motor & fan blade:
13 x 11 x 13.25 (33 x 27.9 x 33.7 cm)11.75 lb (5.3 kg)
Available in 120 Volt or 240 Volt, 185 WattsEBM Backward Curved Impeller
Model 2350 fanStandard
Dimensions:Weight:
Power in:Motor & fan blade:
26 x 25.5 x 9.5 (66 x 65 x 24 cm)34 lb (15.4 kg)Available in 115V or 230V, 50 or 60 Hz, 1000 Watts3/4 hp, PSC motor w/ 8 blade fan
Model 3300SR fanHigh Output
Dimensions:Weight:
Single Phase power in:Motor & fan blade:
26 x 25.5 x 9.5 (66 x 65 x 24 cm)37 lb (16.8 kg)Available in 120V, 15A or 240V 8A, 1ph2.0 hp, 3 phase w/ 8 blade fan
Page 4 of 8
Fan Control
High Output Model 3300SR
Standard Model 2350
Low Flow Model 200
Advanced controlRetrotec ups the ante
with its regulated speedcontrol to eliminate
the speed uctuationsexperienced with typical
manual controls.
Super advanced controlThe unique variable speeddrive provides advancedspeed control withRetrotecs 2 hp HighOutput speed fan. Itgenerates faster speedcontrol with less than0.1% speed variation. Usea 100 to 280V, 50 to 60Hz, wall outlet (non GFCI).
3 sizes of motor in 2 sizes of housing
Choose a 0.25 hp motor in a 10 inch (30 m) housing, or a 0.75 hp or2 hp motor in a 25 inch (75 cm) fan shell housing.
Standard fanLow ow fan
High Output fan and Drive
8-point mount Super stable mounting maintains fan alignment under themost stressful conditions. Attachment points are moldedin permanently, so there is nothing that can come loose.
Tough constructionSpace ageconstruction uses ahollow fan shell lledwith structural foamfor superior strengthand durability.
actoolsupply.com
actoolsupply.com
8/13/2019 AC Spec Selector EnRetrotec US3212 US 3212 Blower Door Air Leakage Test Systemergy SP500
5/8
Model 200 fan (reduce by 15% for 50Hz)Low Flow
Free Air (no ex duct)25 Pa
6807 to 620
3213.3 to 293
115512 to 1054
Model 2350 fan (reduce by 15% for 50Hz)
Standard
Free Air
50 Pa
6,300
5 to 5,600
2,973
2 to 2,643
10,704
8 to 9,514
Model 3300SR fanHigh Output
Free Air
50 Pa
300 Pa
8,500
5 to 8,300
2,300
4,012
2 to 3,917
1,085
14,440
8 to 14,100
3,907
Page 5 of 8
Open
Mid
Low
A
BC
Open
Fan PerformanceMaximum Fan Flow Rates Flow into: CFM L/s m 3 /h
Low Flow fan Range Plates. Standard Range Plates.
Range Rings allow one fan to test a wide range ofenclosures, from super leaky to super tight. Standard andHigh Output fans include 11 ow ranges (far right ) toprovide accurate results over the widest range ofenclosure volumes.
Test the tightest (7 CFM) or leakiest (620 CFM) residentialducts with the three Range Con gurations included withthe Low Flow Model 200 fan ( right ).
Set the Range Con guration on Retrotecs DM-2 digitalgauge to match the installed Range Ring and getinstant and accurate results in any desired units.
The wide span between the minimum/maximum ow on each Range Con guration, coupled with a huge number ofranges, enables faster tests over the widest range of buildings or enclosures.
1 CFM 1 m 3 /hr 1 L/s
1017 5
5 7 100170
47
1,0001,700
472
10,00017,000
4,719
Retrotec Fan Flow for each Range(Flow at 50 Pascals)
OpenOpenMid
Low A
B
C8
C6
C4
C2
C1
L4
L2
L1
Low Flow 200 fans (50Hz) Low Flow 200 fans (60Hz)
Standard fans (110v/50Hz)Standard fans (120v/60Hz)
High Output fans (all voltages)
actoolsupply.com
actoolsupply.com
8/13/2019 AC Spec Selector EnRetrotec US3212 US 3212 Blower Door Air Leakage Test Systemergy SP500
6/8Page 6 of 8
Door Panels
Cloth Door PanelRetrotecs least expensive choice for residential testing.
Options: Extension Kit enlarges the frame horizontally and/or vertically.
High pressure cloth for 300 Pa rain penetration testing. Double hole fan cloth. Small hole fan cloth to mount 200 series fan for tight houses.
Modular Door PanelFor rapid set up and a professional appearance, choose themodular door panels. Three light-weight panels expand to
t the widest doorways.
Options: Small X Panel increases height to 97.5 inches (248 cm).
Three-fan Folding PanelChoose this panel system, exclusive to Retrotec,for testing large open warehouses or stores.
Door widths (max) 47 in (119 cm)
Door height 81 in (205 cm)
Panel case (included) 50 x 30.5 x 5 in (127 x 77.5 x 12.5 cm)
Panel set in case 26 lb (12 kg)
Shipping weight 31 lb (14 kg)
Door widths (min/max) 29.5 to 41.5 in (75 to 105.4 cm)Door heights (max) 51.5 to 95 in (131 to 241 cm)
Frame thickness 1.75 in (5.3 cm)
Frame case (included) 53 x 10 x 4 in (134 x 25 x 10 cm)
Panel set in case 14.2 lb (6.4 kg)
Shipping weight 20 lb (9 kg)
40 to 48 in (102 to 122 cm)
62 to 105 in (157 to 267 cm)
Door widths (min/max) 32 to 48.75 in (81 to 124 cm)Door height (max) 76.5 to 87 in (194 to 221 cm)
Panel case (included) 31 x 30 x 7 in (79 x 76 x 18 cm)
Panel set in case 24 lb (11 kg)
Shipping weight 31 lb (14 kg)
Dimensions
Dimensions
Dimensions with extension kit
X Panel
X-Y Panel
Fan Panel
optional Small X Panel
actoolsupply.com
actoolsupply.com
8/13/2019 AC Spec Selector EnRetrotec US3212 US 3212 Blower Door Air Leakage Test Systemergy SP500
7/8Page 7 of 8
Blower Door Systems
1000 Advanced house testing systemThe 1000 system performs fully automatic testingusing a laptop. Alternatively, simply key in the desiredtest pressure and read Air Changes or leakage per unitarea in real time directly from the gauge; a uniqueRetrotec feature.
Q4E Larger buildings and faster testingThe Q4E system increases fan output from 0.75 hp to2.0 hp. Test large houses and small commercialbuildings with only one fan! Retrotecs exclusive fast,fully automatic control is so quick that it will track andnullify pressure uctuations due to wind.
Q5E Add faster set up and more exibility The Q5E In ltrometer system uses the 2 hp fan andRetrotecs unique modular panel that looks professional,sets up quickly and allows for numerous testingcon gurations that the Aluminum Frame cannotmatch. Ideal for testing high-rise buildings one oor ata time or for multi-family and commerical buildings.
QMGLargest buildingsThe QMG system delivers a whopping 25,000 CFM totest large open warehouses or stores. This purposebuilt system has been used to test more largecommercial buildings than all other systems combined.Use individual fans separately for smaller buildings.
actoolsupply.com
actoolsupply.com
8/13/2019 AC Spec Selector EnRetrotec US3212 US 3212 Blower Door Air Leakage Test Systemergy SP500
8/8
Picture shows optional fan case.
Picture shows fan case & optional tool case.
Picture shows fan case & optional tool case.
All cases included.
All cases included.Case included.
Page 8 of 8
System Components
Q4E
US200DU200
QMG
1000 Q5E
Made in Everson, WA USA
actoolsupply.com
l l