Linear displacement sensors
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
Selection guide
Model Measurement range Output Page
CD50
Up to 1250 mm
Potentiometer (1kΩ) 4 - 5
Analog (0…10V / 4…20mA / 0…20mA) 6 - 7
Incremental 8 - 9
CD60
Up to 1500 mm
Potentiometer (1kΩ) 10 - 11
Analog (0…10V / 4…20mA / 0…20mA) 12 - 13
Incremental 14 - 15
Absolute (SSI / Profibus / CANopen / DeviceNet) 16 - 17
CD80
Up to 2000 mm
Potentiometer (1kΩ) 18 - 19
Analog (0…10V / 4…20mA / 0…20mA) 20 – 21
Up to 2500 mm
Incremental 22 – 23
Absolute (SSI / Profibus / CANopen / DeviceNet) 24 - 25
Mechanical devices (MEC) 26 - 27
CD115
Up to 3000 mm
Potentiometer (1kΩ) 28 - 29
Analog (0…10V / 4…20mA / 0…20mA) 30 - 31
Up to 3500 mm
Incremental 32 - 33
Absolute (SSI / Profibus / CANopen / DeviceNet) 34 - 35
Mechanical devices (MEC) 36 - 37
CD150
Up to 6000 mm
Potentiometer (1kΩ) 38 - 39
Analog (0…10V / 4…20mA / 0…20mA) 40 - 41
Incremental 42 - 43
Absolute (SSI / Profibus / CANopen / DeviceNet) 44 - 45
Mechanical devices (MEC) 46 - 47
AS40
90° to 3600°
Potentiometer (1kΩ) 48 - 49
Analog (0…10V / 4…20mA / 0…20mA) 50 - 51
AS58
90° to 3600°
Potentiometer (1kΩ) 52 - 53
Analog (0…10V / 4…20mA / 0…20mA) 54 - 55
2
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
Selection guide
Model Measurement range Output Page
CDS1210
Up to 10 000 mm
Potentiometer (1kΩ) 56 - 57
Analog (0…10V / 4…20mA / 0…20mA) 58 – 59
Mechanical devices (MEC) 60 – 61
CD1215
Up to 15 000 mm
Potentiometer (1kΩ) 62 – 63
Analog (0…10V / 4…20mA / 0…20mA) 64 – 65
Mechanical devices (MEC) 66 – 67
CD1820
Up to 20 000 mm
Potentiometer (1kΩ) 68 - 69
Analog (0…10V / 4…20mA / 0…20mA) 70 – 71
Mechanical devices (MEC) 72 -73
CD1830
Up to 30 000 mm
Potentiometer (1kΩ) 74 - 75
Analog (0…10V / 4…20mA / 0…20mA) 76 - 77
Mechanical devices (MEC) 78 - 79
CD1840
Up to 40 000 mm
Potentiometer (1kΩ) 80 - 81
Analog (0…10V / 4…20mA / 0…20mA) 82 - 83
Mechanical devices (MEC) 84 - 85
CD1850
Up to 50 000 mm
Potentiometer (1kΩ) 86 - 87
Analog (0…10V / 4…20mA / 0…20mA) 88 - 89
Mechanical devices (MEC) 90 - 91
Output connections
Potentiometric version 84
Analog version 85
Incremental version 86
Options
For draw-wire sensors, CD series 87
For draw-wire sensors, CDS series 88
Adapter flanges for draw-wire sensors, MEC type 89
Accessories
Connectors 90
Mounting accessories 91
Accessories for optical encoders and angular sensors 92
3
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD50 potentiometric output – Measurement range up to 1250 mm
Specifications:
Measurement range 0 up to 1250 mm
Output signal 1kΩ Potentiometer (other values on demand)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - Aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,51 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 – DIN 3 pin
Male connector M12 – 4 pin
PVC cable – 4 wires Cable forces:
Standard linearity +/- 0,25% f.s. – stroke ≤500mm
+/- 0,15% f.s. – stroke >500mm
+/- 0,10% f.s. – stroke >500mm (option)
Protection class IP54 (option IP67)
Max. Velocity 10 M/S
Max. Acceleration 40 M/S2 (before cable deformation)
Weight ≈ 700 g
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Ordering reference:
Model
CD50
Measurement range
0050 = 0 up to 50 mm
0100 = 0 up to 100 mm
0250 = 0 up to 250 mm
0500 = 0 up to 500 mm
0750 = 0 up to 750 mm
1000 = 0 up to 1000 mm
1200 = 0 up to 1200 mm
1250 = 0 up to 1250 mm
(Other range available on demand)
Output signal
R01K = 1kΩ output
(Other values on demand)
Linearity
L25 = +/- 0.25% f.s. (standard for measuring range from 0 to 500mm)
L15 = +/- 0.15% f.s. (standard for measuring range greater than 500 mm)
(option for measuring range from 0 to 500mm)
L10 = +/- 0.10% f.s. (option for measuring range greater than 500 mm)
Connection
C = Male connector M16 – DIN 3 pin
L4 = Male connector M12 – 4 pin
K = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
EM = Fixing of the measuring cable with a clip
EN = Measuring cable coated with polyamide
IP67 = Protection class IP67
M4 = Fixing of the measuring cable with a M4 threaded rod
RAC = Cable dust wiper
TEV = Water evacuation holes
Reference example: CD50-0750-R01R-L15-K02-OP-AC-EM
Measurement
range in mm Min. pull-out force Max. pull-out force
50 ≈ 6,40 N ≈ 6,50 N
100 ≈ 6,30 N ≈ 6,50 N
250 ≈ 6,00 N ≈ 6,50 N
500 ≈ 5,50 N ≈ 6,50 N
750 ≈ 5,00 N ≈ 6,50 N
1000 ≈ 4,50 N ≈ 6,50 N
1200 ≈ 4,00 N ≈ 6,50 N
1250 ≈ 4,00 N ≈ 6,50 N
CD50 OP
4
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
Dimensional drawing
5
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD50 analog output – Measurement range 0 up to 1250 mm
Specifications:
Measurement range 0 up to 1250 mm
Output signal 0…10V (galvanic isolation)
4…20mA current loop
4…20mA current generator (galvanic isolation)
0…20mA current generator (galvanic isolation)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,51 mm
Detection element Multi-turn Hybrid potentiometer Cable forces:
Connection Male connector M16 – DIN 8 pin
Male connector M12 – 4 pin
PVC cable – 4 wires
Standard linearity +/- 0,25% f.s. – stroke ≤500mm
+/- 0,15% f.s. – stroke >500mm
+/- 0,10% f.s. – stroke >500mm (option)
Protection class IP54 (option IP67)
Max. Velocity 10 M/S
Max. Acceleration 40 M/S2 (before cable deformation)
Weight ≈ 700 g
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Ordering reference:
Model
CD50
Measurement range
0050 = 0 up to 50 mm
0100 = 0 up to 100 mm
0250 = 0 up to 250 mm
0500 = 0 up to 500 mm
0750 = 0 up to 750 mm
1000 = 0 up to 1000 mm
1200 = 0 up to 1200 mm
1250 = 0 up to 1250 mm
(Other range available on demand)
Output signal
U010 = 0…10V
I420 = 4…20mA (current loop)
I420G = 4…20mA (current generator)
I020G = 0…20mA (current generator)
Linearity
L25 = +/- 0.25% f.s. (standard for measuring range from 0 up to 500mm)
L15 = +/- 0.15% f.s. (standard for measuring range greater than 500 mm)
(option for measuring range from 0 up to 500mm)
L10 = +/- 0.10% f.s. (option for measuring range greater than 500 mm)
Connection
C = Male connector M16 – DIN 8 pin
L4 = Male connector M12 – 4 pin
K = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
EM = Fixing of the measuring cable with a clip
EN = Measuring cable coated with polyamide
IP67 = Protection class IP67
M4 = Fixing of the measuring cable with a M4 threaded rod
RAC = Cable dust wiper
TEV = Water evacuation holes
Reference example: CD50-0750-U010-L15-K02-OP-AC-EM
Measurement
range in mm Min. pull-out force Max. pull-out force
50 ≈ 6,40 N ≈ 6,50 N
100 ≈ 6,30 N ≈ 6,50 N
250 ≈ 6,00 N ≈ 6,50 N
500 ≈ 5,50 N ≈ 6,50 N
750 ≈ 5,00 N ≈ 6,50 N
1000 ≈ 4,50 N ≈ 6,50 N
1200 ≈ 4,00 N ≈ 6,50 N
1250 ≈ 4,00 N ≈ 6,50 N
CD50 OP
6
20
1530
40
1104
9
60
2
,50
3
0
14,50
2 x 4,50
5
1
2,5
0
30
,50
11
0
70
3
4,5
0
49
49
18 6,50
6
7
5,5
0
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
K Connection(PVC cable - 4 wires)
L4 connection (connector M12 - 4 pin)
C connection(Connector M16 - DIN 8 pin )
1
7,5
0
7
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD50 incremental output - Measurement range 0 to 1250 mm
Specifications:
Measurement range 0 up to 1250 mm
Sensing device Incremental encoder
Supply and output signal 2G2 (5Vdc – Driver 5Vdc RS422)
5G5 (11 to 30Vdc – Push-pull)
9G5 (5 to 24Vdc – Push-pull)
PG5 (5 to 30Vdc – Push-pull)
Resolution 1 – 5 – 10 – 20 or 25 pulses per mm
Material Body and cover - aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,51 mm
Connection Male connector M16 – DIN 8 pin
Male connector M16 – DIN 5 pin
PVC cable – 8 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP54 Cable forces:
Max. Velocity 10 M/S
Max. Acceleration 40 M/S2 (before cable deformation)
Weight ≈ 700 g
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Ordering reference:
Model
CD50
Measurement range
1250 = 0 à 1250 mm
(Or other ranges between 0 and 1250 mm)
Resolution
01 = 1 pulses per mm
05 = 5 pulses per mm
10 = 10 pulses per mm
20 = 20 pulses per mm
25 = 25 pulses per mm
(Other range available on demand)
Supply and output stage
2G2 = 5Vdc – Driver 5Vdc RS422
5G5 = 11 to 30Vdc – Push-pull
9G5 = 5 to 24Vdc – Push-pull
PG5 = 5 to 30Vdc – Push-pull
Linearity
L05 = +/- 0.05% f.s.
L01 = +/- 0.01% f.s. (optional)
Connection
GDA = Male connector M16 – DIN 8 pin
G2A = Male connector M16 – DIN 5 pin
G3R = PVC cable - 8 wires - radial + ex: 020 for cable 2 meters long
G3A = PVC cable - 8 wires - axial + ex: 020 for cable 2 meters long
OP options
AC = Complete anodizing
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
EM = Fixing of the measuring cable with a clip
EN = Measuring cable coated with polyamide
M4 = Fixing of the measuring cable with a M4 threaded rod
RAC = Cable dust wiper
TEV = Water evacuation holes
Reference example: CD50-1250-05-PG5-L05-GDA-OP-AC-EM
Measurement
range in mm Min. pull-out force
Max. pull-out
force
1250 ≈ 4,00 N ≈ 6,50 N
CD50 OP
8
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
Dimensional drawing
9
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD60 potentiometric output – Measurement range 0 up to 1500 mm
Specifications:
Measurement range 0 up to 1500 mm
Output signal 1kΩ potentiometer (other values on demand)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - Aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,60 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 – DIN 3 pin
Male connector M12 – 4 pin
PVC cable – 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP54 (option IP67)
Max. Velocity 10 m/s
Max. Acceleration 20 m/s2 (before cable deformation)
Weight ≈ 1000 g
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CD60
Measurement range
1500 = 0 up to 1500 mm
(Other ranges available on demand)
Output signal
R01K = 1kΩ output
(Other values on demand)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 – DIN 3 pin
L4 = Male connector M12 – 4 pin
K = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
EM = Fixing of the measuring cable with a clip
EN = Measuring cable coated with polyamide
IP67 = Protection class IP67
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
Reference example: CD60-1500-R01K-L15-K02-OP-AC-EM
Measurement
range in mm Min. pull-out force Max. pull-out force
1500 ≈ 9,00 N ≈ 12,00 N
CD60 OP
10
(connector M12 - 4 pin)L4 connection
(PVC cable - 4 wires)K connection
C connection(Connector M16 - DIN 3 pin )
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
58
59
60 19
161
59
18 6,50
3
4,5
0
5
9
9
7,5
0
8
1
32
90
4
,75
76 7
2
3,7
5
4
2
2
15,50
4 x 6,50
11
,50
2
0
1
6,5
0
11
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD60 analog output – Measurement range 0 up to 1500 mm
Specifications:
Measurement range 0 up to 1500 mm
Output signal 0…10V (galvanic isolation)
4…20mA current loop
4…20mA current generator (galvanic isolation)
0…20mA current generator (galvanic isolation)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,60 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 – DIN 8 pin
Male connector M12 – 4 pin
PVC cable – 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP54 (option IP67)
Max. Velocity 10 m/s
Max. Acceleration 20 m/s2 (before cable deformation)
Weight ≈ 1000 g
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CD60
Measurement range
1500 = 0 up to 1500 mm
(Other ranges available on demand)
Output signal
U010 = 0…10V
I420 = 4…20mA (current loop)
I420G = 4…20mA (current generator)
I020G = 0…20mA (current generator)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 – DIN 8 pin
L4 = Male connector M12 – 4 pin
K = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
EM = Fixing of the measuring cable with a clip
EN = Measuring cable coated with polyamide
IP67 = Protection class IP67
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
Reference example: CD60-1500-U010-L15-K02-OP-AC-EM
Measurement
range in mm Min. pull-out force Max. pull-out force
1500 ≈ 9,00 N ≈ 12,00 N
CD60 OP
12
1
6,5
0
K connection(PVC cable - 4 wires)
2
0
6,50 4 x
76 7
2
3,7
5
4
2
2
15,50
1
1,5
0
4
,75
18 6,50
3
4,5
0
59
5
9
9
7,5
0
8
1
32
90
58
59
60 19
161
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
(connector M12 - 4 pin)L4 connection
C connection(Connector M16 - DIN 8 pin )
13
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD60 incremental output - Measurement range 0 up to 1500 mm Specifications:
Measurement range 0 up to 1500 mm
Sensing device Incremental encoder
Supply and output stage 2G2 (5Vdc - Driver 5Vdc RS422)
PG5 (5 to 30Vdc - Push-pull 5-30Vdc)
RG2 (4.75 to 30Vdc - Driver 5Vdc RS422)
5GT (11 to 30Vdc - Transistorized push-pull 11-30Vdc)
Resolution 1 - 5 - 10 - 20 or 25 pulses per mm
Material Body and cover - aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,60 mm
Connection Male connector M23 – 12 pin CW
Male connector M23 – 12 pin CCW
PUR cable – 12 wires
PVC cable – 8 wires
Standard linearity +/- 0,05% f.s.
+/- 0,01% f.s. (optional)
Protection class IP64 Cable forces:
Max. Velocity 10 M/S
Max. Acceleration 20 M/S2 (before cable deformation)
Weight ≈ 1000 g
Operating temperature -20° to +85°C
Storage temperature -40° to +85°C
Ordering reference:
Model
CD60
Measurement range
1500 = 0 to 1500 mm
(Other ranges available on demand)
Resolution
01 = 1 pulses per mm
05 = 5 pulses per mm
10 = 10 pulses per mm
20 = 20 pulses per mm
25 = 25 pulses per mm
(Other values on demand)
Supply and output stage
2G2 = 5Vdc - Driver 5Vdc RS422
PG5 = 5 to 30Vdc - Push-pull 5-30Vdc
RG2 = 4.75 to 30Vdc - Driver 5Vdc RS422
5GT = 11 to 30Vdc - Transistorized push-pull 11-30Vdc
Linearity
L05 = +/- 0.05% f.s.
L01 = +/- 0.01% f.s. (optional)
Connection
G6R = Male connector M23 – 12 pin CW
G8R = Male connector M23 – 12 pin CCW
GP = PUR cable - 12 wires + ex: R020 for cable radial 2 meters long
G3 = PVC cable - 8 wires + ex: R020 for cable radial 2 meters long
OP options
AC = Complete anodizing
BR = Cleaning brush for the cable
CP = Fixing of the measuring cable with a clevis
EM = Fixing of the measuring cable with a clip
EN = Measuring cable coated with polyamide
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
Reference example: CD60-1500-05-PG5-L05-G6R-OP-AC-EM
Measurement
range in mm Min. pull-out force
Max. pull-out
force
1500 ≈ 9,00 N ≈ 12,00 N
CD60 OP
14
54 52,50
19
106,50
119,41
59
60
5
8,5
0
1
32
6,50
59
90
18
3
4,5
0
5
9
9
7,5
0
8
3
7,5
0
15,50
6,50
2
76
4 x
7
4
2
2
3,7
5
4
,75
4
0,7
5
4
0,7
5
With DHM5 encoderG6R or G8R connection
(Male connector M23 - 12 pin CW or CCW)
With DHM5 encoderGPR or G3R connection
(PUR cable - 12 wires or PVC cable - 8 wires )
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France 15
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD60 absolute output - Measurement range 0 up to 1500 mm Specifications:
Measurement range 0 up to 1500 mm
Sensing device Absolute encoder (PHM5 or MHM5 series)
Supply 10 - 30Vdc (MHM5)
5 - 30Vdc (PHM5)
Interface SSI
Profibus
CANopen
DeviceNet
Resolution 13 bits = 8192steps/turns
Distance per turns 150 mm
152,4 mm
Material Body and cover - aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,60 mm
Connection Male connector M23 – 12 pin CW
Male connector M23 – 12 pin CCW
Terminal box
Standard linearity +/- 0,05% f.s.
+/- 0,01% f.s. (optional)
Protection class IP64 Cable forces:
Max. Velocity 10 m/s
Max. Acceleration 20 m/s² (before cable deformation)
Weight ≈ 1000 g
Operating temperature -20° to +85°C
Storage temperature -40° to +85°C
Ordering reference:
Model
CD60
Measurement range
1500 = 0 to 1500 mm
(Other ranges available on demand)
Distance per turns
150 = 150 mm
152 = 152,4 mm
Interface
SSI/1 = MHM5 Serial transmission (SSI)
SSI/2 = PHM5 Serial transmission (SSI)
PROF = MHM5 Profibus transmission
CAN = MHM5 CANopen transmission
DEV = MHM5 DeviceNet transmission
Linearity
L05 = +/- 0.05% f.s.
L01 = +/- 0.01% f.s. (optional)
Connection
H3P = Terminal box (only for MHM5 Profibus and CANopen)
0CC = Terminal box (only for MHM5 DeviceNet)
PRL = 12 pins M23 connector - counter-clockwise (only on MHM5 SSI)
S6R = 12 pins M23 connector - clockwise (only on PHM5 SSI)
S8R = 12 pins M23 connector - counter-clockwise (only on PHM5 SSI)
OP options
AC = Complete anodizing
BR = Cleaning brush for the cable
CP = Fixing of the measuring cable with a clevis
EM = Fixing of the measuring cable with a clip
EN = Measuring cable coated with polyamide
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
Reference example: CD60-1500-152-PROF-L05-H3P-OP-AC-EM
Measurement
range in mm Min. pull-out force
Max. pull-out
force
1500 ≈ 9,00 N ≈ 12,00 N
CD60 OP
16
1
7,5
0
2
0
2
0
58,50
94
,25
ve
rsio
n 0
CC
79
,75
ve
rsio
n H
3P
51
4
8,7
5
72,20
3
9,7
5
(Male connector M23 - 12 pin CW or CCW)S6R or S8R connection
With PHM5 - SSI encoder
(Male connector M23 - 12 pin CCW)PRL connection
With MHM5 - SSI encoder
With MHM5 - PROF/CANO/DNET encoder0CC or H3P connection
(Terminal box)
60
59
19
175 version 0CC
160 version H3P
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
8
59
6,50 18
3
4,5
0
9
7,5
0
5
9
1
32
90
15,50
6,50 4 x
76 7
2
3,7
5
4
2
2
4,7
5
1
36
1
24
,50
17
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD80 potentiometric output – Measurement range 0 up to 2000 mm
Specifications:
Measurement range 0 up to 2000 mm
Output signal 1kΩ potentiometer (other values on demand)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - Aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,60 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 – DIN 3 pin
Male connector M12 – 4 pin
PVC cable – 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP54 (option IP67)
Max. Velocity 10 m/s
Max. Acceleration 8 m/s2 (before cable deformation)
Weight ≈ 1500 g
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CD80
Measurement range
2000 = 0 up to 2000 mm
(Other ranges available on demand)
Output signal
R01K = 1kΩ output
(Other values on demand)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 – DIN 3 pin
L4 = Male connector M12 – 4 pin
K = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
EM = Fixing of the measuring cable with a clip
IP67 = Protection class IP67
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
Reference example: CD80-2000-R01K-L15-K02-OP-AC-EM
Measurement
range in mm Min. pull-out force Max. pull-out force
2000 ≈ 8,00 N ≈ 11,00 N
CD80 OP
18
K connection(PVC cable - 4 wires)
L4 connection(connector M12 - 4 pin)
C connection(Connector M16 - DIN 3 pin )
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
58
161
50
59
29,50
18
7
9
1
52
6,50
3
4,5
0
120
1
17
,50
8
79
10
18,50
9
100
5
4,5
0
2 x
2
5
6,50
11
,50
2
0
1
6,5
0
19
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD80 analog output – Measurement range 0 up to 2000 mm
Specifications:
Measurement range 0 up to 2000 mm
Output signal 0…10V (galvanic isolation)
4…20mA current loop
4…20mA current generator (galvanic isolation)
0…20mA current generator (galvanic isolation)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,60 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 – DIN 8 pin
Male connector M12 – 4 pin
PVC cable – 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP54 (option IP67)
Max. Velocity 10 m/s
Max. Acceleration 8 m/s2 (before cable deformation)
Weight ≈ 1500 g
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CD80
Measurement range
2000 = 0 up to 2000 mm
(Other range available on demand)
Output signal
U010 = 0…10V
I420 = 4…20mA (current loop)
I420G = 4…20mA (current generator)
I020G = 0…20mA (current generator)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 – DIN 8 pin
L4 = Male connector M12 – 4 pin
K = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
EM = Fixing of the measuring cable with a clip
IP67 = Protection class IP67
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
Reference example: CD80-2000-U010-L15-K02-OP-AC-EM
Measurement
range in mm Min. pull-out force Max. pull-out force
2000 ≈ 8,00 N ≈ 11,00 N
CD80 OP
20
1
6,5
0
2
0
6,50 2 x
9
100
5
4,5
0
2
5
10
18,50
1
1,5
0
3
4,5
0
18 6,50
1
52
79
120
1
17
,50
8
79
58
161
50
59
29,50
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
K connection(PVC cable - 4 wires)
L4 connection(connector M12 - 4 pin)
C connection(Connector M16 - DIN 8 pin )
21
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD80 incremental output - Measurement range 0 up to 2500 mm
Specifications:
Measurement range 0 up to 2500 mm
Sensing device Incremental encoder
Supply and output stage 2G2 (5Vdc - Driver 5Vdc RS422)
PG5 (5 to 30Vdc - Push-pull 5-30Vdc)
RG2 (4.75 to 30Vdc - Driver 5Vdc RS422)
5GT (11 to 30Vdc - Transistorized push-pull 11-30Vdc)
Resolution 1 - 5 - 10 - 20 or 25 pulses per mm
Material Body and cover - aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,60 mm
Connection Male connector M23 – 12 pin CW
Male connector M23 – 12 pin CCW
PUR cable - 12 wires
PVC cable - 8 wires
Standard linearity +/- 0,05% f.s.
+/- 0,01% f.s. (optional)
Protection class IP64 Cable forces:
Max. Velocity 10 m/s
Max. Acceleration 8 m/s2 (before cable deformation)
Weight ≈ 1500 g
Operating temperature -20° to +85°C
Storage temperature -40° to +85°C
Ordering reference:
Model
CD80
Measurement range
2500 = 0 up to 2500 mm
(Other ranges available on demand)
Resolution
01 = 1 pulses per mm
05 = 5 pulses per mm
10 = 10 pulses per mm
20 = 20 pulses per mm
25 = 25 pulses per mm
(Other values on-demand)
Supply and output stage
2G2 = 5Vdc - Driver 5Vdc RS422
PG5 = 5 to 30Vdc - Push-pull 5-30Vdc
RG2 = 4.75 to 30Vdc - Driver 5Vdc RS422
5GT = 11 to 30Vdc - Transistorized push-pull 11-30Vdc
Linearity
L05 = +/- 0.05% f.s.
L01 = +/- 0.01% f.s. (optional)
Connection
G6R = Male connector M23 – 12 pin CW
G8R = Male connector M23 – 12 pin CCW
GP = PUR cable - 12 wires + ex: R020 for cable radial 2 meters long
G3 = PVC cable - 8 wires + ex: R020 for cable radial 2 meters long
OP options
AC = Complete anodizing
BR = Cleaning brush for the cable
CP = Fixing of the measuring cable with a clevis
EM = Fixing of the measuring cable with a clip
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
Reference example: CD80-2500-05-PG5-L05-G6R-OP-AC-EM
Measurement
range in mm Min. pull-out force
Max. pull-out
force
2500 ≈ 7,50 N ≈ 11,00 N
CD80 OP
22
52,50
5
1
54
18,50
10
6,50
100
9
5
4,5
0
2
5 2 x
5
2
3
4,5
0
4
7,5
0
6,50
7
9
18
1
52
120
1
17
,50
8
79
59
29,50
119,40
50
106,50
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
With DHM5 encoderGPR or G3R connection
(PUR cable - 12 wires or PVC cable - 8 wires )
With DHM5 encoderG6R or G8R connection
(Male connector M23 - 12 pin CW or CCW)
23
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD80 absolute output - Measurement range 0 up to 2500 mm Specifications:
Measurement range 0 up to 2500 mm
Sensing device Absolute encoder (PHM5 or MHM5 series)
Supply 10 - 30Vdc (MHM5)
5 - 30Vdc (PHM5)
Interface SSI
Profibus
CANopen
DeviceNet
Resolution 13 bits = 8192steps/turns
Distance per turns 200 mm
204,8 mm
Material Body and cover - aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,60 mm
Connection Male connector M23 – 12 pin CW
Male connector M23 – 12 pin CCW
Terminal box
Standard linearity +/- 0,05% f.s.
+/- 0,01% f.s. (optional)
Protection class IP64 Cable forces:
Max. Velocity 10 m/s
Max. Acceleration 8 m/s2 (before cable deformation)
Weight ≈ 1500 g
Operating temperature -20° to +85°C
Storage temperature -40° to +85°C
Ordering reference:
Model
CD80
Measurement range
2500 = 0 à 2500 mm
(Other ranges available on demand)
Distance per turns
200 = 200 mm
204 = 204,8 mm
Interface
SSI/1 = MHM5 Serial transmission (SSI)
SSI/2 = PHM5 Serial transmission (SSI)
PROF = MHM5 Profibus transmission
CAN = MHM5 CANopen transmission
DEV = MHM5 DeviceNet transmission
Linearity
L05 = +/- 0.05% f.s.
L01 = +/- 0.01% f.s. (optional)
Connection
H3P = Terminal box (only for MHM5 Profibus and CANopen)
0CC = Terminal box (only for MHM5 DeviceNet)
PRL = 12 pins M23 connector - counter-clockwise (only on MHM5 SSI)
S6R = 12 pins M23 connector - clockwise (only on PHM5 SSI)
S8R = 12 pins M23 connector - counter-clockwise (only on PHM5 SSI)
OP options
AC = Complete anodizing
BR = Cleaning brush for the cable
CP = Fixing of the measuring cable with a clevis
EM = Fixing of the measuring cable with a clip
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
Reference example: CD80-2500-204-PROF-L05-H3P-OP-AC-EM
Measurement
range in mm Min. pull-out force
Max. pull-out
force
2500 ≈ 7,50 N ≈ 11,00 N
CD80 OP
24
72,20
5
1
58,50
10
5,5
0 v
ers
ion
0C
C
91
ve
rsio
n H
3P
51
6
0
2
0
2
0
2
7,5
0
1
24
,50
2
5
18,50
10 100
9
5
4,5
0
2 x 6,50
1
36
1
17
,50
6,50 18
79
1
52
3
4,5
0
120
8
79
(Male connector M23 - 12 pin CCW)PRL connection
With MHM5 - SSI encoderS6R or S8R connection
With PHM5 - SSI encoder
(Male connector M23 - 12 pin CW or CCW)
With MHM5 - PROF/CANO/DNET encoderH3P or 0CC connection
(Terminal box)
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
50 29,50
59
175 version 0CC
160 version H3P
25
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD80-MEC mechanical devices - Measurement range 0 up to 2500 mm
Specifications:
Measurement range 0 up to 2500 mm
Circumference drum 200 mm/turn
204,8 mm/turn
Sensing device Adaptable with all our incremental or absolute encoders
Material Body and cover - aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,60 mm
Standard linearity +/- 0,05% f.s.
+/- 0,01% f.s. (optional)
Max. Velocity 10 m/s
Max. Acceleration 8 m/s2 (before cable deformation)
Weight ≈ 1500 g
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CD80-MEC
Measurement range
2500 = 0 up to 2500 mm
(Other range available on demand)
Drum circumference
200 = 200 mm/turn
204 = 204,8 mm/turn
Linearity
L05 = +/- 0.05% f.s.
L01 = +/- 0.01% f.s. (optional)
OP options
06 = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange)
10 = Adapter flange for Ø58 encoder with Ø10 axis
12 = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) AC = Complete anodizing
BR = Cleaning brush for the cable
CP = Fixing of the measuring cable with a clevis
EM = Fixing of the measuring cable with a clip
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange.
For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.
Reference example: CD80-MEC-2500-200-L05-OP-10-AC
Measurement
range in mm Min. pull-out force
Max. pull-out
force
2500 ≈ 7,50 N ≈ 11,00 N
CD80 MEC OP
26
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
29,50 50
59
127,40
Oldham coupling adaptable to the detection element that
will be mounted (see options)
7
9
18 6,50
1
52
120
1
17
,50
34
,50
4
7,5
0
8
50 ++
0,050,02
79
100
9
5
4,5
0
2
5
10
18,50
2 x 6,50
27
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD115 potentiometric output – Measurement range 0 up to 3000 mm
Specifications:
Measurement range 0 up to 3000 mm
Output signal 1kΩ potentiometer (other values on demand)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - Aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,60 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 – DIN 3 pin
Male connector M12 – 4 pin
PVC cable – 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP54 (option IP67)
Max. Velocity 10m/s
Max. Acceleration 7 m/s2 (before cable deformation)
Weight ≈ 2000 g
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CD115
Measurement range
3000 = 0 up to 3000 mm
(Other ranges available on demand)
Output signal
R01K = 1kΩ output
(Other values on demand)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 – DIN 3 pin
L4 = Male connector M12 – 4 pin
K = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
IP67 = Protection class IP67
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
BR = Cleaning brush for the cable
Reference example: CD115-3000-R01K-L15-K02-OP-AC-M4
Measurement
range in mm Min. pull-out force Max. pull-out force
3000 ≈ 13,50 N ≈ 18,00 N
CD115 OP
28
115
1
88
3
4,5
0
1
53
,50
155
8
18 6,50
1
15
6
5,5
0
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
(connector M12 - 4 pin)L4 connection
(PVC cable - 4 wires)K connection
C connection(Connector M16 - DIN 3 pin )
89
50 31
162
5
8
2 x
5
6
6,50
2
5
7
,50
20,50
10 135
1
1,5
0
1
6,5
0
2
0
29
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD115 analog output – Measurement range 0 up to 3000 mm
Specifications:
Measurement range 0 up to 3000 mm
Output signal 0…10V (galvanic isolation)
4…20mA current loop
4…20mA current generator (galvanic isolation)
0…20mA current generator (galvanic isolation)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,61 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 – DIN 8 pin
Male connector M12 – 4 pin
PVC cable – 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP54 (option IP67)
Max. Velocity 10 M/S
Max. Acceleration 7 M/S2 (before cable deformation)
Weight ≈ 2000 g
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CD115
Measurement range
3000 = 0 up to 3000 mm
(Other range available on demand)
Output signal
U010 = 0…10V
I420 = 4…20mA (current loop)
I420G = 4…20mA (current generator)
I020G = 0…20mA (current generator)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 – DIN 8 pin
L4 = Male connector M12 – 4 pin
K = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
IP67 = Protection class IP67
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
Reference example: CD115-3000-U010-L15-K02-OP-AC-M4
Measurement
range in mm Min. pull-out force Max. pull-out force
3000 ≈ 13,50 N ≈ 18,00 N
CD115 OP
30
1
6,5
0
6,50 2 x
135
5
6
2
5
10
7
,50
20,50
1
1,5
0
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
6,50 18
1
15
1
88
155
3
4,5
0
115
1
53
,50
8
6
5,5
0
89
162
50 31
5
8
(connector M12 - 4 pin)L4 connection
(PVC cable - 4 wires)K connection
C connection(Connector M16 - DIN 8 pin )
2
0
31
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD115 incremental output - Measurement range 0 up to 3500 mm
Specifications:
Measurement range 0 up to 3500 mm
Sensing device Incremental encoder
Supply and output stage 2G2 (5Vdc - Driver 5Vdc RS422)
PG5 (5 to 30Vdc - Push-pull 5-30Vdc)
RG2 (4.75 to 30Vdc - Driver 5Vdc RS422)
5GT (11 to 30Vdc - Transistorized push-pull 11-30Vdc)
Resolution 1 - 5 - 10 - 20 or 25 pulses per mm
Material Body and cover - aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,60 mm
Connection Male connector M23 – 12 pin CW
Male connector M23 – 12 pin CCW
PUR cable – 12 wires
PVC cable – 8 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP65 Cable forces:
Max. Velocity 10 m/s
Max. Acceleration 7 m/s2 (before cable deformation)
Weight ≈ 2000 g
Operating temperature -20° to +85°C
Storage temperature -40° to +85°C
Ordering reference:
Model
CD115
Measurement range
3500 = 0 up to 3500 mm
(Other ranges available on demand)
Resolution
01 = 1 pulses per mm
05 = 5 pulses per mm
10 = 10 pulses per mm
20 = 20 pulses per mm
25 = 25 pulses per mm
(Other values on demand)
Supply and output stage
2G2 = 5Vdc - Driver 5Vdc RS422
PG5 = 5 to 30Vdc - Push-pull 5-30Vdc
RG2 = 4.75 to 30Vdc - Driver 5Vdc RS422
5GT = 11 to 30Vdc - Transistorized push-pull 11-30Vdc
Linearity
L05 = +/- 0.05% f.s.
L01 = +/- 0.01% f.s. (optional)
Connection
G6R = Male connector M23 – 12 pin CW
G8R = Male connector M23 – 12 pin CCW
GP = PUR cable - 12 wires + ex: R020 for cable radial 2 meters long
G3 = PVC cable - 8 wires + ex: R020 for cable radial 2 meters long
OP options
AC = Complete anodizing
BR = Cleaning brush for the cable
CP = Fixing of the measuring cable with a clevis
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
Reference example: CD115-3500-05-PG5-L05-G6R-OP-AC-M4
Measurement
range in mm Min. pull-out force
Max. pull-out
force
3500 ≈ 13,00 N ≈ 18,00 N
CD115 OP
32
52,50
5
1,5
0
54
6,50
20,50
135
5
6
2
5 2 x
7
,50
10
5
1,5
0
50 31
89
120,50
6,50
1
15
18
1
88
155
3
4,5
0
115
1
53
,50
8
6
5,5
0
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
With DHM5 encoder
(PUR cable - 12 wires or PVC cable - 8 wires )GPR or G3R connection
With DHM5 encoderG6R or G8R connection
(Male connector M23 - 12 pin CW or CCW)
33
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD115 absolute output - Measurement range 0 up to 3500 mm
Specifications:
Measurement range 0 up to 3500 mm
Sensing device Absolute encoder (PHM5 or MHM5 series)
Supply 10 - 30Vdc (MHM5)
5 - 30Vdc (PHM5)
Interface SSI
Profibus
CANopen
DeviceNet
Resolution 13 bits = 8192steps/turns
Distance per turns 300 mm
Material Body and cover - aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,60 mm
Connection Male connector M23 – 12 pin CW
Male connector M23 – 12 pin CCW
Terminal box
Standard linearity +/- 0,05% f.s.
+/- 0,01% f.s. (optional)
Protection class IP64 Cable forces:
Max. Velocity 10 M/S
Max. Acceleration 7 M/S2 (before cable deformation)
Weight ≈ 2000 g
Operating temperature -20° to +85°C
Storage temperature -40° to +85°C
Ordering reference:
Model
CD115
Measurement range
3500 = 0 à 3500 mm
(Other range available on demand)
Distance per turns
300 = 300 mm
Interface
SSI/1 = MHM5 Serial transmission (SSI)
SSI/2 = PHM5 Serial transmission (SSI)
PROF = MHM5 Profibus transmission
CAN = MHM5 CANopen transmission
DEV = MHM5 DeviceNet transmission
Linearity
L05 = +/- 0.05% f.s.
L01 = +/- 0.01% f.s. (optional)
Connection
H3P = Terminal box (only for MHM5 Profibus and CANopen)
0CC = Terminal box (only for MHM5 DeviceNet)
PRL = 12 pins M23 connector - counter-clockwise (only on MHM5 SSI)
S6R = 12 pins M23 connector - clockwise (only on PHM5 SSI)
S8R = 12 pins M23 connector - counter-clockwise (only on PHM5 SSI)
OP options
AC = Complete anodizing
BR = Cleaning brush for the cable
CP = Fixing of the measuring cable with a clevis
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
Reference example: CD115-3500-300-PROF-L05-H3P-OP-AC-M4
Measurement
range in mm Min. pull-out force
Max. pull-out
force
3500 ≈ 13,00 N ≈ 18,00 N
CD115 OP
34
2
0
4
5,5
0
2
0
51
5
9,5
0
58,50
10
5 v
ers
ion
0C
C
90
,50
ve
rsio
n H
3P
5
1
72,20
161 version H3P
50
89
31
176 version 0CC
6
0
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
6,50 18
1
88
3
4,5
0
1
53
,50
1
15
155
8
115
(Male connector M23 - 12 pin CW or CCW)S6R or S8R connection
With PHM5 - SSI encoderPRL connection
(Male connector M23 - 12 pin CCW)
With MHM5 - SSI encoder
With MHM5 - PROF/CANO/DNET encoder0CC or H3P connection
(Terminal box)
1
37
6,50
20,50
7
,50
5
6
2 x
25
10 135
1
25
,50
35
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD115-MEC mechanical devices - Measurement range 0 up to 3500 mm
Specifications:
Measurement range 0 up to 3500 mm
Circumference drum 300 mm/turn
Sensing device Adaptable with all our incremental or absolute encoders
Material Body and cover - aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,60 mm
Standard linearity +/- 0,05% f.s.
+/- 0,01% f.s. (optional)
Max. Velocity 10 m/s
Max. Acceleration 7 m/s2 (before cable deformation)
Weight ≈ 2000 g
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CD115-MEC
Measurement range
3500 = 0 up to 3500 mm
(Other ranges available on demand)
Drum circumference
300 = 300 mm/turn
Linearity
L05 = +/- 0.05% f.s.
L01 = +/- 0.01% f.s. (optional)
OP options
06 = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange)
10 = Adapter flange for Ø58 encoder with Ø10 axis
12 = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) AC = Complete anodizing
BR = Cleaning brush for the cable
CP = Fixing of the measuring cable with a clevis
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange.
For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.
Reference example: CD115-MEC-3500-300-L05-OP-10-AC
Measurement
range in mm Min. pull-out force
Max. pull-out
force
3500 ≈ 13,00 N ≈ 18,00 N
CD115 MEC OP
36
6,50
7
,50
2 x
20,50
5
6
2
5
10 135
128,40
50 31
8
9
Oldham coupling adaptable to the detection element that
will be mounted (see options)
8
0,02
18
155
0,05
3
4,5
0
6
5,5
0
1
53
,50
1
15
1
88
115
50 ++
6,50
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France 37
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD150 potentiometric output – Measurement range 0 up to 6000 mm
Specifications:
Measurement range 0 up to 6000 mm
Output signal 1kΩ potentiometer (other values on demand)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - Aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,60 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 – DIN 3 pin
Male connector M12 – 4 pin
PVC cable – 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP54 (option IP67)
Max. Velocity 10 m/s
Max. Acceleration 5 m/s2 (before cable deformation)
Weight ≈ 3000 g
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CD150
Measurement range
4000 = 0 up to 4000 mm
6000 = 0 up to 6000 mm
(Other ranges available on demand)
Output signal
R01K = 1kΩ output
(Other values on demand)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 – DIN 3 pin
L4 = Male connector M12 – 4 pin
K = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
IP67 = Protection class IP67
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
Reference example: CD150-4000-R01K-L15-K02-OP-AC-M4
Measurement
range in mm Min. pull-out force Max. pull-out force
4000 ≈ 11,00 N ≈ 13,50 N
6000 ≈ 10,00 N ≈ 13,50 N
CD150 OP
38
(connector M12 - 4 pin)
)C connection
(Connector M16 - DIN 3 pinL4 connection
Measurement range up to 4000 mm
6,50
186
148
1
48
1
86
,50
3
4,5
0
8
2
21
18
8
2
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
6,50 4 x
170 8
4
4
8
3
8,2
5
1
2,2
5
20,25
1
1,5
0
171,50
30,25
89
60
58
K connection(PVC cable - 4 wires)
K connection(PVC cable - 4 wires)
2
0
L4 connection(connector M12 - 4 pin)
1
6,5
0
1
6,5
0
20,25
170 8
4 x 6,50
3
8,2
5
8
4
4
1
2,2
5
1
1,5
0
C connection(Connector M16 - DIN 3 pin )
6,50
186
148
1
48
1
86
,50
8
2
21
3
4,5
0
18
1
08
60
89
12
0
138
30,25
Measuring range greater than 4000 mm up to 6000 mm
2
0
39
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD150 analog output – Measurement range 0 up to 6000 mm
Specifications:
Measurement range 0 up to 6000 mm
Output signal 0…10V (galvanic isolation)
4…20mA current loop
4…20mA current generator (galvanic isolation)
0…20mA current generator (galvanic isolation)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,60 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 – DIN 8 pin
Male connector M12 – 4 pin
PVC cable – 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP54 (option IP67)
Max. Velocity 10 m/s
Max. Acceleration 5 m/s2 (before cable deformation)
Weight ≈ 3000 g
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CD150
Measurement range
4000 = 0 up to 4000 mm
6000 = 0 up to 6000 mm
(Other ranges available on demand)
Output signal
U010 = 0…10V
I420 = 4…20mA (current loop)
I420G = 4…20mA (current generator)
I020G = 0…20mA (current generator)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 – DIN 8 pin
L4 = Male connector M12 – 4 pin
K = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
IP67 = Protection class IP67
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
Reference example: CD150-4000-U010-L15-K02-OP-AC-M4
Measurement
range in mm Min. pull-out force Max. pull-out force
4000 ≈ 11,00 N ≈ 13,50 N
6000 ≈ 10,00 N ≈ 13,50 N
CD150 OP
40
8
4
4
1
2,2
5
1
1,5
0
170 8
4 x 6,50
3
8,2
5
20,25
1
6,5
0
20
K connection(PVC cable - 4 wires)
K connection(PVC cable - 4 wires)
2
0
1
6,5
0
20,25
6,50
170
4 x
4
4
8
8
3
8,2
5
1
2,2
5
1
1,5
0
6,50
186
148
1
48
1
86
,50
18
8
3
4,5
0
2
21
8
2
30,25
89
171,50
60
5
8
3
4,5
0
186
1
08
148
1
48
18
1
86
,50
8
2
21
6,50
89
138
60
12
0
30,25
)
C connection(Connector M16 - DIN 8 pin
Measurement range up to 4000 mm
L4 connection(connector M12 - 4 pin)
(connector M12 - 4 pin)L4 connection
)
C connection(Connector M16 - DIN 8 pin
Measuring range greater than 4000 mm up to 6000 mm
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France 41
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD150 incremental output - Measurement range 0 up to 6000 mm
Specifications:
Measurement range 0 up to 6000 mm
Sensing device Incremental encoder
Supply and output stage 2G2 (5Vdc - Driver 5Vdc RS422)
PG5 (5 to 30Vdc - Push-pull 5-30Vdc)
RG2 (4.75 to 30Vdc - Driver 5Vdc RS422)
5GT (11 to 30Vdc - Transistorized push-pull 11-30Vdc)
Resolution 1 - 5 - 10 - 20 or 25 pulses per mm
Material Body and cover - aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,60 mm
Connection Male connector M23 – 12 pin CW
Male connector M23 – 12 pin CCW
12-wires PUR cable
8-wires PVC cable
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP65 Cable forces:
Max. Velocity 10 M/S
Max. Acceleration 5 M/S2 (before cable deformation)
Weight ≈ 3000 g
Operating temperature -20° to +85°C
Storage temperature -40° to +85°C
Ordering reference:
Model
CD150
Measurement range
6000 = 0 up to 6000 mm
(Other ranges available on demand)
Resolution
01 = 1 pulses per mm
05 = 5 pulses per mm
10 = 10 pulses per mm
20 = 20 pulses per mm
25 = 25 pulses per mm
(Other values on demand)
Supply and output stage
2G2 = 5Vdc - Driver 5Vdc RS422
PG5 = 5 to 30Vdc - Push-pull 5-30Vdc
RG2 = 4.75 to 30Vdc - Driver 5Vdc RS422
5GT = 11 to 30Vdc - Transistorized push-pull 11-30Vdc
Linearity
L05 = +/- 0.05% f.s.
L01 = +/- 0.01% f.s. (optional)
Connection
G6R = Male connector M23 – 12 pin CW
G8R = Male connector M23 – 12 pin CCW
GP = PUR cable - 12 wires + ex: R020 for cable radial 2 meters long
G3 = PVC cable - 8 wires + ex: R020 for cable radial 2 meters long
OP options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
Reference example: CD150-6000-05-PG5-L05-G6R-OP-AC-M4
Measurement
range in mm Min. pull-out force
Max. pull-out
force
6000 ≈ 10,00 N ≈ 13,50 N
CD150 OP
42
130
52,50
3
4,7
5
54
58
,50
89
60 30,25 148
186
8
2
1
48
1
86
,50
18
8
2
21
3
4,5
0
6,50
170
12
,25
20,25
3
4,7
5
4
4
8
8
3
8,2
5
4 x 6,50
With DHM5 encoder
(Male connector M23 - 12 pin CW or CCW)G6R or G8R connection
With DHM5 encoderGPR or G3R connection
(PUR cable - 12 wires or PVC cable - 8 wires )
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France 43
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD150 absolute output - Measurement range 0 up to 6000 mm
Specifications:
Measurement range 0 up to 6000 mm
Sensing device Absolute encoder (PHM5 or MHM5 series)
Supply 10 - 30Vdc (MHM5)
5 - 30Vdc (PHM5)
Interface SSI
Profibus
CANopen
DeviceNet
Resolution 13 bits = 8192steps/turns
Distance per turns 409,6 mm
Material Body and cover - aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,60 mm
Connection Male connector M23 – 12 pin CW
Male connector M23 – 12 pin CCW
Terminal box
Standard linearity +/- 0,05% f.s.
+/- 0,01% f.s. (optional)
Protection class IP64 Cable forces:
Max. Velocity 10 M/S
Max. Acceleration 5 M/S2 (before cable deformation)
Weight ≈ 3000 g
Operating temperature -20° to +85°C
Storage temperature -40° to +85°C
Ordering reference:
Model
CD150
Measurement range
6000 = 0 à 6000 mm
(Other ranges available on demand)
Distance per turns
409 = 409,6 mm
Interface
SSI/1 = MHM5 Serial transmission (SSI)
SSI/2 = PHM5 Serial transmission (SSI)
PROF = MHM5 Profibus transmission
CAN = MHM5 CANopen transmission
DEV = MHM5 DeviceNet transmission
Linearity
L05 = +/- 0.05% f.s.
L01 = +/- 0.01% f.s. (optional)
Connection
H3P = Terminal box (only for MHM5 Profibus and CANopen)
0CC = Terminal box (only for MHM5 DeviceNet)
PRL = 12 pins M23 connector - counter-clockwise (only on MHM5 SSI)
S6R = 12 pins M23 connector - clockwise (only on PHM5 SSI)
S8R = 12 pins M23 connector - counter-clockwise (only on PHM5 SSI)
OP options
AC = Complete anodizing
BR = Cleaning brush for the cable
CP = Fixing of the measuring cable with a clevis
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
Reference example: CD150-6000-409-PROF-L05-H3P-OP-AC-M4
Measurement
range in mm Min. pull-out force
Max. pull-out
force
6000 ≈ 10,00 N ≈ 13,50 N
CD150 OP
44
6
2
2
0
20
8
8,2
5 v
ers
ion
0C
C
73
,75
ve
rsio
n H
3P
4
2,7
5
51 72,20
3
3,5
0
(Male connector M23 - 12 pin CCW)
With MHM5 - SSI encoderPRL connection
(Male connector M23 - 12 pin CW or CCW)S6R or S8R connection
With PHM5 - SSI encoderWith MHM5 - PROF/CANO/DNET encoder
0CC or H3P connection(Terminal box)
186
148
2
21
1
48
1
86
,50
18
8
3
4,5
0
6,50 Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
1
2,2
5
20,25
170
4
4
8
8
3
8,2
5
4 x 6,50
6
0
89
60 30,25
185,50 version 0CC
170,50 version H3P
1
46
,50
1
35
45
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD150-MEC mechanical devices - Measurement range 0 up to 6000 mm
Specifications:
Measurement range 0 up to 6000 mm
Circumference drum 409,6 mm/turn
Sensing device Adaptable with all our incremental or absolute encoders
Material Body and cover - aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,60 mm
Standard linearity +/- 0,05% f.s.
+/- 0,01% f.s. (optional)
Max. Velocity 10 m/s
Max. Acceleration 5 m/s2 (before cable deformation)
Weight ≈ 3000 g
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CD150-MEC
Measurement range
6000 = 0 up to 6000 mm
(Other ranges available on demand)
Drum circumference
409 = 409,6 mm/turn
Linearity
L05 = +/- 0.05% f.s.
L01 = +/- 0.01% f.s. (optional)
OP options
06 = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange)
10 = Adapter flange for Ø58 encoder with Ø10 axis
12 = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) AC = Complete anodizing
BR = Cleaning brush for the cable
CP = Fixing of the measuring cable with a clevis
M4 = Fixing of the measuring cable with a M4 threaded rod
TEV = Water evacuation holes
If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange.
For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.
Reference example: CD150-MEC-6000-409-L05-OP-10-AC
Measurement
range in mm Min. pull-out force
Max. pull-out
force
6000 ≈ 10,00 N ≈ 13,50 N
CD150 MEC OP
46
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
78
89
60 30,25
137,90
Oldham coupling adaptable to the detection element that
will be mounted (see options)
8
2
186
1
86
,50
34
,50
8
2
21
18 6,50
1
48
148
50 ++
0,050,02
170
20,25
8
4
4
8
3
8,2
5
1
2,2
5
4 x 6,50
47
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CDS1210 potentiometric output – Measurement range 0 up to 10 000 mm
Specifications:
Measurement range 0 up to 10 000 mm
Output signal 1kΩ potentiometer (other values on demand)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - Aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,90 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 - DIN 3 pin
Male connector M12 - 4 pin
PVC cable - 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP65
Max. Velocity 10 m/s
Max. Acceleration 5 m/s2 (before cable deformation)
Weight ≈ 6 kg
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CDS1210
Measurement range
10000 = 0 up to 10 000 mm
(Other ranges available on demand)
Output signal
R01K = 1kΩ output
(Other values on demand)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 - DIN 3 pin
L4 = Male connector M12 - 4 pin
K = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
IP67 = Protection class IP67
M6 = Fixing of the measuring cable with a M6 threaded rod
TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1210-10000-R01K-L15-K02-OP-AC-M6
Measurement
range in mm Min. pull-out force Max. pull-out force
10 000 ≈ 10,50 N ≈ 15,00 N
CDS1210 OP
48
11,50
1
72
,50
Modular base plate
)
(PVC cable - 4 wires)K connection
C connection(Connector M16 - DIN 3 pin
L4 connection(connector M12 - 4 pin)
1
6,5
0
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
102
12
0
216
12
0
66
1
0
30
20,20
4
0
6
0
115
1
8,5
0
8
4,5
0
10
9
3
0
47
1
1,5
0
40,50
120
135
1
28
1
14
8
9
4
2
0
6
8
26
1
32
49
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD1210 analog output – Measurement range 0 up to 10 000 mm
Specifications:
Measurement range 0 up to 10 000 mm
Output signal 0…10V (galvanic isolation)
4…20mA current loop
4…20mA current generator (galvanic isolation)
0…20mA current generator (galvanic isolation)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,90 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 - DIN 8 pin
Male connector M12 - 4 pin
PVC cable - 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP65
Max. Velocity 10 M/S
Max. Acceleration 5 M/S2 (before cable deformation)
Weight ≈ 6 kg
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CDS1210
Measurement range
10000 = 0 up to 10 000 mm
(Other ranges available on demand)
Output signal
U010 = 0…10V
I420 = 4…20mA (current loop)
I420G = 4…20mA (current generator)
I020G = 0…20mA (current generator)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 - DIN 8 pin
L4 = Male connector M12 - 4 pin
K = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
IP67 = Protection class IP67
M6 = Fixing of the measuring cable with a M6 threaded rod
TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1210-10000-U010-L15-K02-OP-AC-M6
Measurement
range in mm Min. pull-out force Max. pull-out force
10 000 ≈ 11,00 N ≈ 13,50 N
CDS1210 OP
50
11,50
1
72
,50
(connector M12 - 4 pin)
Modular base plate
L4 connection(PVC cable - 4 wires)
K connection C connection(Connector M16 - DIN 8 pin )
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
216
102
12
0
12
0
66
1
14
135
120
1
28
9
4
8
10
30
20,20
4
0
6
0
115
1
8,5
0
8
4,5
0
1
1,5
0
10
9
3
0
47
40,50
1
6,5
0
2
0
26
6
8
1
30
,50
51
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CDS1210-MEC mechanical devices - Measurement range 0 up to 10 000 mm
Specifications:
Measurement range 0 up to 10 000 mm
Circumference drum 300 mm/turn
Sensing device Adaptable with all our incremental or absolute encoders
Material Body and cover - aluminium (RohS)
Measuring cable – Stainless steel
Cable diameter 0,90 mm
Standard linearity +/- 0,05% f.s.
+/- 0,01% f.s. (optional)
Max. Velocity 10 m/s
Max. Acceleration 5 m/s2 (before cable deformation)
Weight ≈ 6kg
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CDS1210-MEC
Measurement range
10000 = 0 up to 10 000 mm
(Other ranges available on demand)
Drum circumference
300 = 300 mm/turn
Linearity
L05 = +/- 0.05% f.s.
L01 = +/- 0.01% f.s. (optional)
OP options
06 = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange)
10 = Adapter flange for Ø58 encoder with Ø10 axis
12 = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
M6 = Fixing of the measuring cable with a M6 threaded rod
TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange.
For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.
Reference example: CDS1210-MEC-10000-300-L05-OP-10-AC
Measurement
range in mm Min. pull-out force
Max. pull-out
force
10 000 ≈ 10,50 N ≈ 15,00 N
CDS1210 MEC OP
52
1
72
,50
11,50
6
8
1
32
3
0
10
47
20,20
4
0
30
6
0
115
1
8,5
0
8
4,5
0
9
1
0
40,50
Oldham coupling adaptable to the detection element that
will be mounted (see options)
6
8
135
120
8
1
28
1
14
50 ++
0,050,02
102 66
12
0
181
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
Modular base plate
53
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CDS1215 potentiometric output – Measurement range 0 up to 15 000 mm
Specifications:
Measurement range 0 up to 15 000 mm
Output signal 1kΩ potentiometer (other values on demand)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - Aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,90 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 - DIN 3 pin
Male connector M12 - 4 pin
PVC cable - 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP65
Max. Velocity 10 m/s
Max. Acceleration 4 m/s2 (before cable deformation)
Weight ≈ 8 kg
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CDS1215
Measurement range
15000 = 0 up to 15 000 mm
(Other ranges available on demand)
Output signal
R01K = 1kΩ output
(Other values on demand)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 - DIN 3 pin
L4 = Male connector M12 - 4 pin
K = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
IP67 = Protection class IP67
M6 = Fixing of the measuring cable with a M6 threaded rod
TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1215-15000-R01K-L15-K02-OP-AC-M6
Measurement
range in mm Min. pull-out force Max. pull-out force
15 000 ≈ 10,50 N ≈ 15,00 N
CDS1215 OP
54
1
72
,50
11,50
L4 connection(connector M12 - 4 pin)(PVC cable - 4 wires)
K connection
C connection(Connector M16 - DIN 3 pin )
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
120
135
1
28
1
14
8
9
4
12
0
311,50
137,50
128
1
20
1
80
,50
5
2,5
0
4
0
6
0
1
1,5
0
9
20,20
30
3
0
47
10 115
1
0
40,50
1
6,5
0
Modular base plate
2
0
6
8
26
1
32
55
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD1215 analog output – Measurement range 0 up to 15 000 mm
Specifications:
Measurement range 0 up to 15 000 mm
Output signal 0…10V (galvanic isolation)
4…20mA current loop
4…20mA current generator (galvanic isolation)
0…20mA current generator (galvanic isolation)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,90 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 - DIN 8 pin
Male connector M12 - 4 pin
PVC cable - 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP65
Max. Velocity 10 m/s
Max. Acceleration 4 m/s2 (before cable deformation)
Weight ≈ 8 kg
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CDS1215
Measurement range
15000 = 0 up to 15 000 mm
(Other ranges available on demand)
Output signal
U010 = 0…10V
I420 = 4…20mA (current loop)
I420G = 4…20mA (current generator)
I020G = 0…20mA (current generator)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 - DIN 8 pin
L4 = Male connector M12 - 4 pin
K = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
IP67 = Protection class IP67
M6 = Fixing of the measuring cable with a M6 threaded rod
TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1215-15000-U010-L15-K02-OP-AC-M6
Measurement
range in mm Min. pull-out force Max. pull-out force
15 000 ≈ 10,50 N ≈ 15,00 N
CDS1215 OP
56
1
72
,50
11,50
(connector M12 - 4 pin)L4 connection )
(PVC cable - 4 wires)K connection
C connection(Connector M16 - DIN 8 pin
Modular base plate
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
1
28
135
1
14
120
8
9
4
311,50
137,50 128
12
0
1
20
1
80
,50
5
2,5
0
4
0
6
0
9
20,20
30
3
0
47
10 115
1
1,5
0
1
0
40,50
1
6,5
0
2
0
6
8
26
1
32
57
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CDS1215-MEC mechanical devices - Measurement range 0 up to 15 000 mm
Specifications:
Measurement range 0 up to 15 000 mm
Circumference drum 300 mm/turn
Sensing device Adaptable with all of our incremental or absolute encoders
Material Body and cover - aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,90 mm
Standard linearity +/- 0,05% f.s.
+/- 0,01% f.s. (optional)
Max. Velocity 10 m/s
Max. Acceleration 4 m/s² (before cable deformation)
Weight ≈ 8kg
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CDS1215-MEC
Measurement range
15000 = 0 up to 15 000 mm
(Other ranges available on demand)
Drum circumference
300 = 300 mm/turn
Linearity
L05 = +/- 0.05% f.s.
L01 = +/- 0.01% f.s. (optional)
OP options
06 = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange)
10 = Adapter flange for Ø58 encoder with Ø10 axis
12 = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
M6 = Fixing of the measuring cable with a M6 threaded rod
TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange.
For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.
Reference example: CDS1215-MEC-15000-300-L05-OP-10-AC
Measurement
range in mm Min. pull-out force
Max. pull-out
force
15 000 ≈ 10,50 N ≈ 15,00 N
CDS1215 MEC OP
58
1
72
,50
11,50
Modular base plate
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
Oldham coupling adaptable to the detection element that
will be mounted (see options)
135
6
8
8
1
28
1
14
120
50 ++
0,050,02
128 137,50
12
0
276,50
115
1
80
,50
4
0
47
20,20
6
0
9
30
10
5
2,5
0
3
0
1
0
40,50
1
32
59
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CDS1820 potentiometric output – Measurement range 0 up to 20 000 mm
Specifications:
Measurement range 0 up to 20 000 mm
Output signal 1kΩ potentiometer (other values on demand)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - Aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,90 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 - DIN 3 pin
Male connector M12 - 4 pin
PVC cable - 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP65
Max. Velocity 10 m/s
Max. Acceleration 2 m/s2 (before cable deformation)
Weight ≈ 12 kg
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CDS1820
Measurement range
20000 = 0 up to 20 000 mm
(Other ranges available on demand)
Output signal
R01K = 1kΩ output
(Other values on demand)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 - DIN 3 pin
L4 = Male connector M12 - 4 pin
K = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
IP67 = Protection class IP67
M6 = Fixing of the measuring cable with a M6 threaded rod
TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1820-20000-R01K-L15-K02-OP-AC-M6
Measurement
range in mm Min. pull-out force Max. pull-out force
20 000 ≈ 15,00 N ≈ 30,00 N
CDS1820 OP
60
2
18
,50
1
79
317,50
110
12
0
154,50
1
80
2
0
1
70
1
00
26
1
6,5
0
1
1,5
0
20
180
3
8
10
48,50
6
0
8
0
17,50
1
74
,50
2
0
9
1
0
30
(connector M12 - 4 pin)K connection
(PVC cable - 4 wires)
)L4 connection
C connection(Connector M16 - DIN 3 pin
Modular base plate
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
180
1
90
200 1
0
1
26
61
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD1820 analog output – Measurement range 0 up to 20 000 mm
Specifications:
Measurement range 0 up to 20 000 mm
Output signal 0…10V (galvanic isolation)
4…20mA current loop
4…20mA current generator (galvanic isolation)
0…20mA current generator (galvanic isolation)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,90 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 - DIN 8 pin
Male connector M12 - 4 pin
PVC cable - 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP65
Max. Velocity 10 m/s
Max. Acceleration 2 m/s2 (before cable deformation)
Weight ≈ 12 kg
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CDS1820
Measurement range
20000 = 0 up to 20 000 mm
(Other ranges available on demand)
Output signal
U010 = 0…10V
I420 = 4…20mA (current loop)
I420G = 4…20mA (current generator)
I020G = 0…20mA (current generator)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 - DIN 8 pin
L4 = Male connector M12 - 4 pin
K = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
IP67 = Protection class IP67
M6 = Fixing of the measuring cable with a M6 threaded rod
TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1820-20000-U010-L15-K02-OP-AC-M6
Measurement
range in mm Min. pull-out force Max. pull-out force
20 000 ≈ 15,00 N ≈ 30,00 N
CDS1820 OP
62
1
79
2
18
,50
K connection(PVC cable - 4 wires)
L4 connection(connector M12 - 4 pin)
Modular base plate
C connection(Connector M16 - DIN 3 pin )
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
200
180
1
90
1
0
1
26
2
0
1
70
26
1
00
12
0
317,50
110 154,50
1
80
8
0
20
180
30
1
0
3
8
48,50
17,50
6
0
10
1
74
,50
2
0
9
1
1,5
0
1
6,5
0
63
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CDS1820-MEC mechanical devices - Measurement range 0 up to 20 000 mm
Specifications:
Measurement range 0 up to 20 000 mm
Circumference drum 500 mm/turn
Sensing device Adaptable with all of our incremental or absolute encoders
Material Body and cover - aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,90 mm
Standard linearity +/- 0,05% f.s.
+/- 0,01% f.s. (optional)
Max. Velocity 10 m/s
Max. Acceleration 2 m/s2 (before cable deformation)
Weight ≈ 12kg
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CDS1820-MEC
Measurement range
20 000 = 0 up to 20 000 mm
(Other ranges available on demand)
Drum circumference
500 = 500 mm/turn
Linearity
L05 = +/- 0.05% f.s.
L01 = +/- 0.01% f.s. (optional)
OP options
06 = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange)
10 = Adapter flange for Ø58 encoder with Ø10 axis
12 = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
M6 = Fixing of the measuring cable with a M6 threaded rod
TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange.
For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.
Reference example: CDS1820-MEC-20000-500-L05-OP-10-AC
Measurement
range in mm Min. pull-out force
Max. pull-out
force
20 000 ≈ 15,00 N ≈ 30,00 N
CDS1820 MEC OP
64
1
79
11
2
18
,50
Modular base plate
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
Oldham coupling adaptable to the detection element that
will be mounted (see options)
1
00
1
90
1
0
200
180
50 ++
0,050,02
1
70
1
00
154,50
18
0
110
282,50
1
0
20
180
3
8
10
48,50
6
0
8
0
17,50
1
74
,50
2
0
9
30
65
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CDS1830 potentiometric output – Measurement range 0 up to 30 000 mm
Specifications:
Measurement range 0 up to 30 000 mm
Output signal 1kΩ potentiometer (other values on demand)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - Aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,90 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 - DIN 3 pin
Male connector M12 - 4 pin
PVC cable - 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP65
Max. Velocity 10 m/s
Max. Acceleration 2 m/s2 (before cable deformation)
Weight ≈ 15 kg
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CDS1830
Measurement range
30000 = 0 up to 30 000 mm
(Other ranges available on demand)
Output signal
R01K = 1kΩ output
(Other values on demand)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 - DIN 3 pin
L4 = Male connector M12 - 4 pin
K = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
IP67 = Protection class IP67
M6 = Fixing of the measuring cable with a M6 threaded rod
TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1830-30000-R01K-L15-K02-OP-AC-M6
Measurement
range in mm Min. pull-out force Max. pull-out force
30 000 ≈ 15,00 N ≈ 30,00 N
CDS1830 OP
66
1
79
11
2
18
,50
20
180
1
83
5
0
9
0
2
0
9
10
3
5
1
1,5
0
48,50
2
1,5
0
28,50
30
Modular base plate
L4 connection(connector M12 - 4 pin)
K connection(PVC cable - 4 wires)
148
354
160
1
15
1
80
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
C connection(Connector M16 - DIN 3 pin )
1
90
200
180
1
0
1
26
2
0
1
6,5
0
1
00
26
1
70
67
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD1830 analog output – Measurement range 0 up to 30 000 mm
Specifications:
Measurement range 0 up to 30 000 mm
Output signal 0…10V (galvanic isolation)
4…20mA current loop
4…20mA current generator (galvanic isolation)
0…20mA current generator (galvanic isolation)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,90 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 - DIN 8 pin
Male connector M12 - 4 pin
PVC cable - 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP65
Max. Velocity 10 m/s
Max. Acceleration 2 m/s2 (before cable deformation)
Weight ≈ 15 kg
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CDS1830
Measurement range
30000 = 0 up to 30 000 mm
(Other ranges available on-demand)
Output signal
U010 = 0…10V
I420 = 4…20mA (current loop)
I420G = 4…20mA (current generator)
I020G = 0…20mA (current generator)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 - DIN 8 pin
L4 = Male connector M12 - 4 pin
K = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
IP67 = Protection class IP67
M6 = Fixing of the measuring cable with a M6 threaded rod
TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1830-30000-U010-L15-K02-OP-AC-M6
Measurement
range in mm Min. pull-out force Max. pull-out force
30 000 ≈ 15,00 N ≈ 30,00 N
CDS1830 OP
68
11
2
18
,50
1
79
1
15
354
160 148
1
80
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
K connection(PVC cable - 4 wires)
)L4 connection(connector M12 - 4 pin)
C connection(Connector M16 - DIN 3 pin
Modular base plate
1
00
26
1
70
1
6,5
0
20
20
180
1
83
5
0
9
0
2
0
9
10
3
5
48,50
1
1,5
0
28,50
2
1,5
0
30
1
90
200
180
1
0
1
26
69
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CDS1830-MEC mechanical devices - Measurement range 0 up to 30 000 mm
Specifications:
Measurement range 0 up to 30 000 mm
Circumference drum 500 mm/turn
Sensing device Adaptable with all our incremental or absolute encoders
Material Body and cover - aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,90 mm
Standard linearity +/- 0,05% f.s.
+/- 0,01% f.s. (optional)
Max. Velocity 10 m/s
Max. Acceleration 2 m/s2 (before cable deformation)
Weight ≈ 15kg
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CDS1830-MEC
Measurement range
30 000 = 0 up to 30 000 mm
(Other ranges available on demand)
Drum circumference
500 = 500 mm/turn
Linearity
L05 = +/- 0.05% f.s.
L01 = +/- 0.01% f.s. (optional)
OP options
06 = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange)
10 = Adapter flange for Ø58 encoder with Ø10 axis
12 = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
M6 = Fixing of the measuring cable with a M6 threaded rod
TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange.
For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.
Reference example: CDS1830-MEC-30000-500-L05-OP-10-AC
Measurement
range in mm Min. pull-out force
Max. pull-out
force
30 000 ≈ 15,00 N ≈ 30,00 N
CDS1830 MEC OP
70
2
18
,50
11
1
79
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
1
00
1
70
Oldham coupling adaptable to the detection element that
will be mounted (see options)
1
90
200
180
1
0
50 ++
0,050,02
1
00
Modular base plate1
80
148 160
319
20
28,50
180
1
83
2
1,5
0
5
0
9
0
2
0
9
3
5
48,50
10
30
71
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CDS1840 potentiometric output – Measurement range 0 up to 40 000 mm
Specifications:
Measurement range 0 up to 40 000 mm
Output signal 1kΩ potentiometer (other values on demand)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - Aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,90 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 - DIN 3 pin
Male connector M12 - 4 pin
PVC cable - 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP65
Max. Velocity 10 m/s
Max. Acceleration 1 m/s2 (before cable deformation)
Weight ≈ 20 kg
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CDS1840
Measurement range
40000 = 0 up to 40 000 mm
(Other ranges available on demand)
Output signal
R01K = 1kΩ output
(Other values on demand)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 - DIN 3 pin
L4 = Male connector M12 - 4 pin
K = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
IP67 = Protection class IP67
M6 = Fixing of the measuring cable with a M6 threaded rod
TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1840-40000-R01K-L15-K02-OP-AC-M6
Measurement
range in mm Min. pull-out force Max. pull-out force
40 000 ≈ 15,00 N ≈ 30,00 N
CDS1840 OP
72
1
79
11
2
18
,50
)L4 connection
(PVC cable - 4 wires)K connection
(connector M12 - 4 pin)
C connection(Connector M16 - DIN 3 pin
Modular base plate
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
180
427
1
15
18
0
180
200
1
90
180
1
0
1
26
10 180
48,37
20
30
2
35
5
5
9
0
5
0
2
0
9
28,50
2
1,5
0
1
1,5
0 2
0
1
6,5
0
1
00
1
70
26
73
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD1840 analog output – Measurement range 0 up to 40 000 mm
Specifications:
Measurement range 0 up to 40 000 mm
Output signal 0…10V (galvanic isolation)
4…20mA current loop
4…20mA current generator (galvanic isolation)
0…20mA current generator (galvanic isolation)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,90 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 – DIN 8 pin
Male connector M12 – 4 pin
PVC cable – 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP65
Max. Velocity 10 m/s
Max. Acceleration 1 m/s2 (before cable deformation)
Weight ≈ 20 kg
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CDS1840
Measurement range
40000 = 0 up to 40 000 mm
(Other ranges available on demand)
Output signal
U010 = 0…10V
I420 = 4…20mA (current loop)
I420G = 4…20mA (current generator)
I020G = 0…20mA (current generator)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 – DIN 8 pin
L4 = Male connector M12 – 4 pin
K = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
IP67 = Protection class IP67
M6 = Fixing of the measuring cable with a M6 threaded rod
TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1840-40000-U010-L15-K02-OP-AC-M6
Measurement
range in mm Min. pull-out force Max. pull-out force
40 000 ≈ 15,00 N ≈ 30,00 N
CDS1840 OP
74
1
79
11
2
18
,50
K connection(PVC cable - 4 wires)
427
180
18
0
1
15
180
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
Modular base plate
C connection(Connector M16 - DIN 8 pin )
200
1
90
180
1
0
1
26
2
1,5
0
10 180
48,50
20
30
2
35
5
5
9
0
5
0
2
0
9
28,50
1
1,5
0 2
0
L4 connection(connector M12 - 4 pin)
1
6,5
0
1
00
26
1
70
75
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CDS1840-MEC mechanical devices - Measurement range 0 up to 40 000 mm
Specifications:
Measurement range 0 up to 40 000 mm
Circumference drum 500 mm/turn
Sensing device Adaptable with all our incremental or absolute encoders
Material Body and cover - aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,90 mm
Standard linearity +/- 0,05% f.s.
+/- 0,01% f.s. (optional)
Max. Velocity 10 m/s
Max. Acceleration 1 m/s2 (before cable deformation)
Weight ≈ 20kg
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CDS1840-MEC
Measurement range
40 000 = 0 up to 40 000 mm
(Other ranges available on demand)
Drum circumference
500 = 500 mm/turn
Linearity
L05 = +/- 0.05% f.s.
L01 = +/- 0.01% f.s. (optional)
OP options
06 = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange)
10 = Adapter flange for Ø58 encoder with Ø10 axis
12 = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
M6 = Fixing of the measuring cable with a M6 threaded rod
TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange.
For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.
Reference example: CDS1840-MEC-40000-500-L05-OP-10-AC
Measurement
range in mm Min. pull-out force
Max. pull-out
force
40 000 ≈ 15,00 N ≈ 30,00 N
CDS1840 MEC OP
76
1
79
11
2
18
,50
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
Oldham coupling adaptable to the detection element that
will be mounted (see options)
200 1
0
1
00
1
90
180
50 ++
0,050,02
10 180
20
30
2
35
5
5
9
0
2
0
5
0
9
2
1,5
0
28,50
48,50
1
70
1
00
Modular base plate
180 180
18
0
392
77
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CDS1850 potentiometric output – Measurement range 0 up to 50 000 mm
Specifications:
Measurement range 0 up to 50 000 mm
Output signal 1kΩ potentiometer (other values on demand)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - Aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,90 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 - DIN 3 pin
Male connector M12 - 4 pin
PVC cable - 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP65
Max. Velocity 10 m/s
Max. Acceleration 1 m/s2 (before cable deformation)
Weight ≈ 23 kg
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CDS1850
Measurement range
50000 = 0 up to 50 000 mm
(Other ranges available on demand)
Output signal
R01K = 1kΩ output
(Other values on demand)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 - DIN 3 pin
L4 = Male connector M12 - 4 pin
K = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
IP67 = Protection class IP67
M6 = Fixing of the measuring cable with a M6 threaded rod
TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1850-50000-R01K-L15-K02-OP-AC-M6
Measurement
range in mm Min. pull-out force Max. pull-out force
50 000 ≈ 15,00 N ≈ 30,00 N
CDS1850 OP
78
1
79
11
2
18
,50
K connection(PVC cable - 4 wires)
L4 connection(connector M12 - 4 pin)
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
200
467
18
0
12
0
180 180
1
90
200 1
0
1
26
C connection(Connector M16 - DIN 3 pin )
30
180
9
0
5
0
2
55
7
5
2
0
9
10
1
1,5
0
2
1,5
0
48,50
28,50
20
2
0
1
6,5
0
Modular base plate
1
00
26
1
70
79
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CD1850 analog output – Measurement range 0 up to 50 000 mm
Specifications:
Measurement range 0 up to 50 000 mm
Output signal 0…10V (galvanic isolation)
4…20mA current loop
4…20mA current generator (galvanic isolation)
0…20mA current generator (galvanic isolation)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,90 mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 – DIN 8 pin
Male connector M12 – 4 pin
PVC cable – 4 wires
Standard linearity +/- 0,15% f.s.
+/- 0,10% f.s. (optional)
Protection class IP65
Max. Velocity 10 m/s
Max. Acceleration 1 m/s2 (before cable deformation)
Weight ≈ 23 kg
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CDS1850
Measurement range
50000 = 0 up to 50 000 mm
(Other ranges available on demand)
Output signal
U010 = 0…10V
I420 = 4…20mA (current loop)
I420G = 4…20mA (current generator)
I020G = 0…20mA (current generator)
Linearity
L15 = +/- 0.15% f.s.
L10 = +/- 0.10% f.s. (optional)
Connection
C = Male connector M16 – DIN 8 pin
L4 = Male connector M12 – 4 pin
K = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
IP67 = Protection class IP67
M6 = Fixing of the measuring cable with a M6 threaded rod
TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1850-50000-U010-L15-K02-OP-AC-M6
Measurement
range in mm Min. pull-out force Max. pull-out force
50 000 ≈ 15,00 N ≈ 30,00 N
CDS1850 OP
80
1
79
11
2
18
,50
Modular base plate
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
12
0
467
200
1
80
180
1
90
200
180
1
0
1
26
C connection(Connector M16 - DIN 8 pin )
30
180
2
1,5
0
28,50
9
0
5
0
2
55
7
5
1
1,5
0
2
0
9
10
20
48,50
K connection(PVC cable - 4 wires)
2
0
L4 connection(connector M12 - 4 pin)
1
6,5
0
1
00
26
1
70
81
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
CDS1850-MEC mechanical devices - Measurement range 0 up to 50 000 mm
Specifications:
Measurement range 0 up to 50 000 mm
Circumference drum 500 mm/turn
Sensing device Adaptable with all our incremental or absolute encoders
Material Body and cover - aluminium (RohS)
Measuring cable - Stainless steel
Cable diameter 0,90 mm
Standard linearity +/- 0,05% f.s.
+/- 0,01% f.s. (optional)
Max. Velocity 10 m/s
Max. Acceleration 1 m/s2 (before cable deformation)
Weight ≈ 23kg
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Cable forces:
Ordering reference:
Model
CDS1850-MEC
Measurement range
50 000 = 0 up to 50 000 mm
(Other ranges available on demand)
Drum circumference
500 = 500 mm/turn
Linearity
L05 = +/- 0.05% f.s.
L01 = +/- 0.01% f.s. (optional)
OP options
06 = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange)
10 = Adapter flange for Ø58 encoder with Ø10 axis
12 = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) AC = Complete anodizing
BR = Cleaning brush for the cable
BT = Low temperature (down to -30°C)
CP = Fixing of the measuring cable with a clevis
M6 = Fixing of the measuring cable with a M6 threaded rod
TEV = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange.
For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.
Reference example: CDS1850-MEC-50000-500-L05-OP-10-AC
Measurement
range in mm Min. pull-out force
Max. pull-out
force
50 000 ≈ 15,00 N ≈ 30,00 N
CDS1850 MEC OP
82
11
2
18
,50
1
79
Modular base plate
1
00
1
70
2
1,5
0
30
180
9
0
5
0
48,50
2
55
7
5
2
0
9
10
20
28,50
Oldham coupling adaptable to the detection element that
will be mounted (see options)
180
1
0
1
00
1
90
200
50 ++
0,050,02
200
18
0
180
432
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France 83
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
AS40 potentiometric output – Measurement range from 90 to 3600°
Specifications:
Measurement range 90 to 3600°
Output signal 1kΩ Potentiometer (other values on demand)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - Aluminium (RohS)
Measuring cable – Stainless steel 303
Axis diameter 10mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 – DIN 3 pin
Male connector M12 – 4 pin
PVC cable – 4 wires
Linearity +/- 0,25% fs (other values on demand)
Shock resistance ≤ 300m.s-2
(11 ms)
Vibration resistance ≤ 100m.s-2
(10 … 500 Hz)
Protection class IP65 (other on demand)
Weight ≈ 200 g
Operating temperature -10° to +70°C
Storage temperature -20° to +100°C
Ordering reference:
Model
AS40
Measurement range
0090 = 90°
0180 = 180°
0340 = 340°
1800 = 1800°
3600 = 3600°
(other values on demand)
Output signal
R01K = 1kΩ output
(Other values on demand)
Output sense
H = CW
A = CCW
Linearity
L50 = +/- 0.50% FS (standard for ranges up to 340°)
L25 = +/- 0.25% FS (standard for ranges superior than 340°)
(optional for ranges up to 340°)
L15 = +/- 0.15% FS (optional for ranges superior than 340°)
Connection
C = Male connector M16 – DIN 3 pin
L4 = Male connector M12 – 4 pin
K = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options
IP67 = Protection class IP67
Reference example: AS40-3600-R01K-H-L25-K02-OP-IP67
AS40 OP
84
28
40
3 x M3 5 at 120°
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
L4 connection(connector M12 - 4 pin)
K connection(PVC cable - 4 wires)
C connection(Connector M16 - DIN 3 pin )
48
3
57,50
3
2
0 f
7
1,50
17
6 g
7
36
f7
3
2
2
12,50
17,50
20
85
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
AS40 Analog output – Measurement range from 90 to 3600°
Specifications:
Measurement range 90 to 3600°
Output signal - 0…10V
- 4…20mA Current loop
- 4…20mA Current generator - 0…20mA Current generator
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - Aluminium (RohS)
Measuring cable – Stainless steel 303
Axis diameter 10mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 – 8 pin
Male connector M12 – 4 pin
PVC cable – 4 wires
Linearity +/- 0,25% fs (other values on demand)
Shock resistance ≤ 300m.s-2
(11 ms)
Vibration resistance ≤ 100m.s-2
(10 … 500 Hz)
Protection class IP65 (other on demand)
Weight ≈ 200 g
Operating temperature -10° to +70°C
Storage temperature -20° to +100°C
Ordering reference:
Model
AS40
Measurement range
0090 = 90°
0180 = 180°
0340 = 340°
1800 = 1800°
3600 = 3600°
(other values on demand)
Output signal
U010 = Output 0…10V
I420 = Output 4…20mA (2-wires current loop)
I420G = Output 4…20mA (current generator)
I020G = Output 0…20mA (current
Output sense
H = CW
A = CCW
Linearity
L50 = +/- 0.50% FS (standard for ranges up to 340°)
L25 = +/- 0.25% FS (standard for ranges superior than 340°)
(optional for ranges up to 340°)
L15 = +/- 0.15% FS (optional for ranges superior than 340°)
Connection
C = Male connector M16 – 8 pin
L4 = Male connector M12 – 4 pin
K = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options
IP67 = Protection class IP67
Reference example: AS40-3600-i420-H-L25-K02-OP-IP67
AS40 OP
86
28
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
)
(connector M12 - 4 pin)L4 connection
C connection(Connector M16 - DIN 8 pin
K connection(PVC cable - 4 wires)
20
17,50
3
60
3
1,50
2
0 f
7
17
6 g
7
36
f7
3
2
12,50
2
69,50
40
3 x M3 5 at 120°
87
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0
Made in France
AS58 potentiometric output – Measurement range from 90 to 3600°
Specifications:
Measurement range 90 to 3600°
Output signal 1kΩ Potentiometer (other values on demand)
Resolution Quasi infinite (depends on the operating system)
Material Body and cover - Aluminium (RohS)
Measuring cable – Stainless steel 303
Axis diameter 10mm
Detection element Multi-turn Hybrid potentiometer
Connection Male connector M16 – DIN 3 pin
Male connector M12 – 4 pin
PVC cable – 4 wires
Linearity +/- 0,50% fs – Range from 340° and 1080°
+/- 0,25% fs – Range from 1800° and 3600°
Range from 340° and 1080° (optional)
+/- 0,15% fs – Range from 1800° and 3600° (optional)
Shock resistance ≤ 500m.s-2
(6 ms)
Vibration resistance ≤ 100m.s-2
(55 … 2 000 Hz)
Protection class IP54 (option IP67)
Weight ≈ 300 g
Operating temperature -20° to +80°C
Storage temperature -30° to +80°C
Ordering reference:
Model
CD50
Measurement range
0340 = 0 to 340°
1080 = 0 to 1080°
1800 = 0 to 1800°
3600 = 0 to 3600°
Output signal
R01K = 1kΩ output
(Other values on demand)
Linearity
L50 = +/- 0.50% fs (standard for range from 340° and 1080°)
L25 = +/- 0.25% fs (standard for range from 1800° and 3600°)
(optional for range from 340° and 1080°)
L15 = +/- 0.15% fs (optional for range from 1800° and 3600°)
Connection
C = Male connector M16 – DIN 3 pin
L4 = Male connector M12 – 4 pin
K = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options
AC = Complete anodizing
BT = Low temperature (down to -30°C)
IP67 = Protection class IP67
Reference example: AS58-3600-R01K-H-L25-K02-OP-IP67
CD50 OP
88
48
19 10
3
1,7
5
10
g7
78 11,50
2
3
6
16,50
20
(connector M12 - 4 pin)L4 connection
(PVC cable - 4 wires)K connection
C connection(Connector M16 - DIN 3 pin ) 58
3 x M4 6 at 120°
3 x M3 6 at 120°
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France 89
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
AS58 Analog output – Measurement range from 90 to 3600° Specifications: Measurement range 90 to 3600° Output signal 0…10V (galvanic isolation) 4…20mA ; 2 wires technique 4…20mA ; 4 wires technique (galvanic isolation) 0…20mA ; 4 wires technique (galvanic isolation) Resolution Quasi infinite (depends on the operating system) Material Body and cover - Aluminium (RohS)
Measuring cable – Stainless steel 303 Axis diameter 10mm Detection element Multi-turn Hybrid potentiometer Connection Male connector M16 –8 pin
Male connector M12 – 4 pin PVC cable – 4 wires Linearity +/- 0,50% fs – Range ≤ 340° +/- 0,25% fs – Range > 340° Range ≤ 340° (optional) +/- 0,15% fs – Range > 340° (optional)
Shock resistance 500m.s-2 (6 ms)
Vibration resistance 100m.s-2 (55 … 2 000 Hz) Protection class IP54 (option IP67) Weight ≈ 700 g Operating temperature -20° to +80°C Storage temperature -30° to +80°C Ordering reference:
Model
AS58 Measurement range
0340 = 0 to 340° 1080 = 0 to 1080° 1800 = 0 to 1800° 3600 = 0 to 3600° (Other values on demand) Output signal
U010 = 0…10V I420 = 4…20mA (2 wires technique) I420G = 4…20mA (4 wires technique) I020G = 0…20mA (4 wires technique) Linearity
L50 = +/- 0.50% fs (standard for ranges from 340° to 1080°) L25 = +/- 0.25% fs (standard for ranges from 1800° to 3600°)
(optional for ranges from 340° to 1080°) L15 = +/- 0.15% fs (optional for ranges from 1800° to 3600°) Connection
C = Male connector M16 – DIN 8 L4 = Male connector M12 – 4 pin K = PVC cable – 4 wires + ex: 02 for cable 2 meters long OP Options
AC = Complete anodizing BT = Low temperature (down to -30°C) IP67 = Protection class IP67 Reference example: AS58-3600-U010-H-L25-K02-OP-IP67
AS58 OP
90
48
58
6 at 120° 3 x M4
3 x M3 6 at 120°
16,50
20
(connector M12 - 4 pin)L4 connection
(PVC cable - 4 wires)K connection
C connection(Connector M16 - DIN 8 pin )
Dimensional Drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0Made in France
19 10
10
g7
3
1,7
5
78 11,50
2
3
6
91
We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France
Electrical characteristics for draw-wire sensors with potentiometric output
Potentiometric version 1 K : (other values on demand) Temperature drift +/-50 ppm/°C
Example of wiring diagram with input stage :
To ensure a good linearity, wire the potentiometer as a voltage divider and never as a rheostat. The input resistance of the operating system must be very high (greater than 10MΩ) Connection :
Male connector M16 3 pin (DIN)
Male connector M12 4 pin (DIN)
PVC cable 4 wire
R01K
1 1 Brown Input voltage +
2 2 White Input voltage GND
3 3 Green Signal +
Sensor side view
Sensor side view
92
We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France
Electrical characteristics for draw-wire sensors with analog output Analog version 0 … 10V : Input voltage 15 to +27 Vdc (52mA max) Output voltage 0 to 10 Vdc Output current 10mA max Galvanic isolation 3KV Protection - Short circuit - Polarity reversal Temperature drift +/-100 ppm/°C Analog version 4 … 20mA : (Two-wires current loop) Input voltage +15 to +27 Vdc (32mA max) Output current 4 to 20mA Protection - Short circuit - Polarity reversal Temperature drift +/-100 ppm/°C Analog version 4…20mA or 0…20mA : (Current generator) Input voltage +15 to +27 Vdc (75mA max) Output current 4 to 20mA or 0 to 20mA Output current 22 mA max. Galvanic isolation 3KV Protection - Short circuit - Polarity reversal Temperature drift +/-100 ppm/°C Connection :
Male connector M16 8 pin (DIN)
Male connector M12 4 pin (DIN)
PVC cable 4 wire
010V I420
(current loop) I420G or I020G
(current generator)
1 1 Brown Input voltage + Signal + Input voltage +
2 2 White Input voltage GND Signal - Input voltage GND
3 3 Green Signal + Signal +
4 4 Yellow Signal GND Signal GND
Sensor side view
Sensor side view
93
We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France
Electrical characteristics for draw-wire sensors with incremental output Electronic 2G2 (100kHz) (for CD50)
Supply : 5Vdc 10% Cons. without load : 100mA max Current per channel: 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = 2,5Vdc
Electronic 5G5 (100kHz) Supply: 11 à 30Vdc Cons. without load: 75mA max Current per channel: 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = Vcc-3Vdc
Electronic 9G5 (100kHz) Supply: 5 à 24Vdc Cons. without load: 75mA max Current per channel: 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = Vcc-3Vdc
Electronic PG5 (100kHz) (for CD50) Supply: 5 à 30Vdc Cons. without load: 75mA max Current per channel: 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = Vcc-3Vdc
Electronic 2G2 (100°C, 300kHz) Supply : 5Vdc 10% Cons. without load : 75mA max Current per channel : 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = 4Vdc
Electronic PG5 (100°C, 300kHz) Supply : 5 to 30Vdc Cons. without load : 75mA max Current per channel : 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = Vcc-2,5Vdc
Electronic RG2 (100°C, 300kHz) Supply : 4,75 to 30Vdc Cons. without load : 75mA max Current per channel : 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = 4Vdc
Electronic 5GT (70°C, 120kHz) Supply : 11 to 30Vdc Cons. without load : 75mA max Current per channel : 40mA max 0 max (Is=20mA) : Vol = 1,5Vdc 1 min (Is=20mA) : Voh = Vcc-2,5Vdc
Connection:
Male connector M23
12 Pin - CW
Male connector M23
12 Pin - CCW
Male connector M16 8 pin (DIN)
Male connector M16 5 pin (DIN)
PVC cable 8 wire
PUR cable 12 wire
Standard connection
1 10 + 11 1 1 White White +
White/Green Supply -
2 2 + 12 2 2 Brown Brown +
Brown/Green Supply +
3 8 3 3 Green Grey A
4 5 4 4 Yellow Brown B
5 3 5 5 Grey Red 0
6 1 6 / Pink Pink A/
7 6 7 / Blue Green B/
8 4 8 / Red Black 0/
Sensor side view
Sensor side view
Sensor side view
Sensor side view
PUR 12-Leiter-
Kabel
94
We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France
Options for draw-wire sensors, CD Series Cable attachment with a lug : Standard The attachment lug is fixed with a M6 screw or a clevis. Available for : CD50, CD60, CD80, CD115, CD150
Cable attachment with a clip : OP-EM This fastening system allows a rotation about its axis. The clip is fixed with a M4 screw or a clevis. Available for : CD50, CD60, CD80
Cable attachment fitted with a M4 threaded rod: OP-M4 The rod attachment uses a threaded rod with 2 nuts (provided). The required thickness of the plate
does not exceed 5 mm. Caution Never screw the threaded rod into a fixed nut, a twist of the measurement cable would damage it. Available for : CD50, CD60, CD80, CD115, CD150
Cable attachment with a clevis : OP-CP The attachment of the clevis is done using a pin (provided). Available for : CD50, CD60, CD80, CD115, CD150
Cable dust wiper OP-RAC The dust wiper cleans the cable in dusty or humid environments. Available for : CD50
Cable cleaning brush: OP-BR The cleaning brush wipes the cable in dusty or humid environments. Available for : CD60, CD80, CD115, CD150
Water evacuation holes: OP-TEV The holes allow the natural flow of fluids out of the sensor in order to avoid their accumulation in the system. Available for : CD50, CD60, CD80, CD115, CD150
95
We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France
Options for draw-wire sensors, CDS Series
Cable attachment with a lug : Standard Measuring cable attachment with a lug. The attachment mounted on ball bearings allows a free rotation relative to the measurement cable. Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850
Cable attachment fitted with a M6 threaded rod: OP-M6 The rod attachment uses a threaded rod with 2 nuts (provided). The required thickness of the plate does not exceed 8mm. The attachment mounted on ball bearings allows a free rotation relative to the measurement cable. Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850
Cable cleaning brush: OP-BR The cleaning brush wipes the cable in dusty or humid environments. Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850
Cable attachment with a clevis : OP-CP The attachment of the clevis is done using a pin (provided). The attachment mounted on ball bearings allows a free rotation relative to the measurement cable. Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850
Water evacuation holes: OP-TEV The holes allow the natural flow of fluids out of the sensor in order to avoid their accumulation in the system. Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850
Please specify the implantation angle of the drain holes on the drawing below.
(All value between 0 and 360°)
96
We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France
Adapter flanges Adaptation for an encoder of diameter 58mm, and shaft diameter 6mm OP-06: Adaptation flange + Ø6 Oldham coupling OP-06A: Ø6 Oldham coupling without adaptation flange Adaptation for an encoder of diameter 58mm, and shaft diameter 10mm OP-10: Adaptation flange + Ø10 Oldham coupling Without specification, a MEC series draw-wire sensor will always be delivered with an Oldham coupling Ø10 without adaptation flange.
Adaptation for an encoder of diameter 90mm, and shaft diameter 12mm OP-12: Adaptation flange + Ø12 Oldham coupling OP-12A: Ø12 Oldham coupling without adaptation flange
97
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
Connectors
Female connectors
M12 4-Pins Female connector
For M-connection
Ø of the cable: 4 to 6 mm
Ref : 5100-020
M16 Female connector - DIN
For C-connection (3-Pins)
Ø of the cable: 4 to 6 mm
Ref: 5100-007
M16 Female connector - DIN
For C-connection (8-Pins)
Ø of the cable: 4 to 6 mm
Ref: 5100-008
M23 CCW female connector
For G6-connection (mounting on CW baseplate)
Ø of the cable: 6 to 8 mm
Ref: 5100-006
M23 CW female connector
For G8-connection (mounting on CCW baseplate)
Ø of the cable: 6 to 8 mm
Ref: 5100-005
98
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
Mounting accessories
Magnet clamp FAIM-5 (for CD50)
Magnet clamp FAIM-25 (for CD115 and CD150)
Pulley PR01 (for CD50)
Pulley PR03
Cable extension
- M4 cable plugs on both ends. Ref. : RL-XXXX-M4/M4
- Attachment heads on both ends. Ref. : RL-XXXX-CP/CP
- Cable lugs on both ends. Ref. : RL-XXXX-CO/CO
Other possibilities: RL-XXXX-M4/CO (M4 screw at one end – lug on the other) RL-XXXX-M4/CP (M4 screw at one end – attachment head on the other) RL-XXXX-CO/CP (Lug at one end – attachment head on the other Possibility to integrate directly the cable extension into the sensor
Heating module for draw-wire sensors, series CDS
The heating module prevents the sensor to freeze under negative
operating temperature.
Don’t hesitate to contact us for any further information
99
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
Accessories
Clearance compensation angle Fixation angle
Ref : ERJ40-002 Ref : EF058-001
Measuring wheel Oldham coupling
Ref : RM200-001
Cylindrical eccentric (to mount angular sensors and optical encoders)
Provided with a set of 4 eccentrics + 4 screws
Ref : EXC-001 Ref : EXC-002
100