Data sheet

Key features

•HighperformanceadvancedLayer3modularswitchwithVSFstacking,lowlatencyandresiliency.

•HPESmartRateforhigh-speedmulti-gigabitbandwidthandPoE+power.

•Scalablelinerate40GbEforwirelesstrafficaggregation.

•OptimizedforinnovativeSDNapplicationswithOpenFlowsupport.

•SecurityandnetworkmanagementtoolswithClearPassPolicyManagerandAirWavesupport.

Product overview

TheAruba5400Rzl2SwitchSeriesisanindustry-leadingmobilecampusaccesssolutionwithHPESmartRatemulti-gigabitportsforhigh-speed802.11acdevices.Itdeliversenterprise-classresiliencywithinnovativeflexibilityandscalabilityforcustomerscreatingdigitalworkplacesthatareoptimizedformobileuserswithanintegratedwiredandwirelessapproach.ThisseriesbringsscalableaggregationwithVirtualSwitchingFramework(VSF)stackingtechnology,hitlessfailover,andFastSoftwareUpgradefor5400RVSFstacks.TheadvancedLayer2and3featuresetincludesOSPF,IPv6,IPv4BGP,TunneledNode,robustQoSandpolicy-basedroutingwithnosoftwarelicensingrequired.

BasedonapowerfulProVisionASIC,theAruba5400Rzl2SwitchSerieshasahigh-speed,high-capacityarchitecturewith2Tbpscrossbarswitchingfabricwithlow2.1μlatency,unprecedentedprogrammability,andsupportsinnovativeSDNapplications.Thisseriesoffersflexibleconnectivityoptionswith6-or12-slotcompactchassis,linerate40GbE,upto96linerate10GbEportsandupto288portsofPoE+.The5400RisSDNoptimizedwithOpenFlowsupportandiseasytodeployandmanagewithadvancedsecurityandnetworkmanagementtoolslikeArubaClearPassPolicyManagerandArubaAirWave.

Aruba 5400R zl2 Switch Series

Page 2Data sheet

Features and benefits

Software-defined networking•OpenFlow

SupportsOpenFlow1.0and1.3specificationstoenableSDNbyallowingseparationofthedata(packetforwarding)andcontrol(routingdecision)paths

•FullyflexibleOpenFlow

CreatescustomOpenFlowpipelines(processingstages)on-demandtosupportnewSDNapplications(requiresv3modules)

Unified Wired and Wireless•ClearPassPolicyManager

SupportsunifiedwiredandwirelesspoliciesusingArubaClearPassPolicyManager

•HTTPredirectfunction

SupportsHPEIntelligentManagementCenter(IMC)bringyourowndevice(BYOD)solution

•Switchauto-configuration

AutomaticallyconfiguresswitchfordifferentsettingssuchasVLAN,CoS,PoEmaxpower,andPoEprioritywhenArubaAPisdetected

•UserRole

Asetofswitch-basedpoliciesinareassuchassecurity,authentication,andQoS.AUserRolecanbeassignedtoagroupofusersordevices,usingswitchconfigurationorClearPass

•Per-portTunneledNode

Providesecuredtunneltotransportnetworktrafficonaper-portbasistoArubaController.AuthenticationandnetworkpolicieswillbeappliedandenforcedattheController

•New StaticIPVisibility

AllowsClearPasstodoaccountingforclientswithstaticIPaddress

Quality of Service (QoS)•Advancedclassifier-basedQoS

ClassifiestrafficusingmultiplematchcriteriabasedonLayer2,3,and4information;appliesQoSpoliciessuchassettingprioritylevelandratelimittoselectedtrafficonaper-portorperVLANbasis

•Trafficprioritization

Allowsreal-timetrafficclassificationintoeightprioritylevelsmappedtoeightqueues

Page 3Data sheet

•Bandwidthshaping

–Port-basedratelimiting

providesper-portingress-/egress-enforcedincreasedbandwidth

–Classifier-basedratelimiting

usesanaccesscontrollist(ACL)toenforceincreasedbandwidthforingresstrafficoneachport

–Reducedbandwidth

providesper-port,per-queueegress-basedreducedbandwidth

•ClassofService(CoS)

SetstheIEEE802.1pprioritytagbasedonIPaddress,IPTypeofService(ToS),Layer3protocol,TCP/UDPportnumber,sourceport,andDiffServ

Management•Zero-TouchProvisioning(ZTP)

SimplifiesinstallationoftheswitchinfrastructureusingArubaActivate-basedorDHCP-basedprocesswithAirWaveNetworkManagement

•New IPSLAforVoice

MonitorqualityofvoicetrafficwithUDPJitterandUDPJitterforVoIP(requiresv3modules)

•Remoteintelligentmirroring

Mirrorsselectedingress/egresstrafficbasedonACL,port,MACaddress,orVLANtoalocalorremoteHPE8200zl,6600,6200yl,5400zl,5400R,3500,or3800Switchlocatedanywhereonthenetwork

•RMON,XRMON,andsFlow®v5

Provideadvancedmonitoringandreportingcapabilitiesforstatistics,history,alarms,andevents

•IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)

Advertisesandreceivesmanagementinformationfromadjacentdevicesonanetwork,facilitatingeasymappingbynetworkmanagementapplications

•Uni-DirectionalLinkDetection(UDLD)

SupportHewlettPackardEnterprise(HPE)UDLDandDLDPprotocolstomonitoracablebetweentwoswitchesandshutdowntheportsonbothendsifthecableisbroken

•Managementsimplicity

ProvidescommonsoftwarefeaturesandCLIimplementationacrossallHPEProVision-basedswitches(includingthezlandylswitches)

•Commandauthorization

LeveragesRADIUStolinkacustomlistofCLIcommandstoanindividualnetworkadministrator’slogin;anaudittraildocumentsactivity

Page 4Data sheet

•Friendlyportnames

Allowsassignmentofdescriptivenamestoports

•Dualflashimages

Providesindependentprimaryandsecondaryoperatingsystemfilesforbackupwhileupgrading

•Multipleconfigurationfiles

Storeseasilytotheflashimage

•ComwareCLI

–Comware-compatibleCLI

bridgestheexperienceofHPEComwareCLIuserswhoareusingtheHPEProVisionsoftwareCLI

–DisplayandfundamentalComwareCLIcommands

areembeddedintheswitchCLIasnativecommands;displayoutputisformattedasonComware-basedswitches,andfundamentalcommandsprovideaComware-familiarinitialswitchsetup

–ConfigurationComwareCLIcommands

whenComwarecommandsareentered,CLIhelpiselicitedtoformulatethecorrectProVisionsoftwareCLIcommand

Connectivity•IEEE802.3azEnergyEfficientEthernet

Lowerspowerconsumptioninperiodsoflowlinkusage(supportedonv2zl10/100/1000and10/100modules)

•IEEE802.3afPoweroverEthernet(PoE)

Providesupto15.4WperporttoIEEE802.3af-compliantPoE-powereddevicessuchasIPphones,wirelessaccesspoints,andsecuritycameras

•IEEE802.3atPoweroverEthernetPlus

Providesupto30Wperport,forupto288portssimultaneously,forPoE-andPoE+-powereddevices,suchasvideoIPphones,IEEE802.11nwirelessaccesspoints,andadvancedpan/zoom/tiltsecuritycameras

•PrestandardPoEsupport

DetectsandprovidespowertoprestandardPoEdevices

Page 5Data sheet

•High-densityportconnectivity

Providesupto12interfacemoduleslotsandupto288wire-speed10/100/1000PoE-enabledportsor96 10GbEportspersystem

•Jumboframes

OnGigabitEthernetand10-GigabitEthernetports,jumboframesallowhigh-performanceremotebackupanddisaster-recoveryservices

•Auto-MDIX

Providesautomaticadjustmentsforstraight-throughorcrossovercablesonall10/100and10/100/1000ports

•IPv6

– IPv6host

enablesswitchestobemanagedinanIPv6network

–Dualstack(IPv4andIPv6)

transitionsfromIPv4toIPv6,supportingconnectivityforbothprotocols

–MLDsnooping

forwardsIPv6multicasttraffictotheappropriateinterface

– IPv6ACL/QoS

supportsACLandQoSforIPv6networktraffic

– IPv6routing

supportsstatic,RIPng,andOSPFv3routingprotocols

–6in4tunneling

supportsencapsulationofIPv6trafficinIPv4packets

–Security

providesRAguard,DHCPv6protection,dynamicIPv6lockdown,andNDsnooping

Performance•High-speed,high-capacityarchitecture

2Tbpscrossbarswitchingfabricprovidesintra-moduleandinter-moduleswitchingwith785.7millionppsthroughputonthepurpose-builtProVisionASICs

•Selectablequeueconfigurations

Allowsforincreasedperformancebyselectingthenumberofqueuesandassociatedmemorybufferingthatbestmeettherequirementsofthenetworkapplications

Page 6Data sheet

Resiliency and high availability•VirtualSwitchingFramework(VSF)

Createsonevirtualresilientswitchfromtwoswitches;serversorswitchescanbeattachedusingstandardLACPforautomaticloadbalancingandhighavailability;simplifynetworkoperationbyreducetheneedforcomplexprotocolslikeSpanningTreeProtocol(STP),Equal-CostMultipath(ECMP),andVRRP(requiresv3modules)

•New FastSoftwareUpgrade

ReducesdowntimeoftheVSFstackduringanupgradebysequentiallyupgradingthemembersinthestackshrinkingthedowntimetoafewseconds(requiresv3modules)

•VirtualRouterRedundancyProtocol(VRRP)

AllowsgroupsoftworouterstodynamicallybackeachotheruptocreatehighlyavailableroutedenvironmentsforIPv4andIPv6networks

•Nonstopswitching

Improvesnetworkavailabilitytobettersupportcriticalapplicationssuchasunifiedcommunicationandmobility;interfaceandfabricmodulescontinueswitchingtrafficduringfailoverfromactivetostandbymanagementmodule

•Nonstoprouting

EnhancesLayer3highavailability;OSPFv2/v3andVRRPwillcontinuetooperateandroutenetworktrafficduringfailoverfromanactivetoastandbymanagementmodule

•Redundantmanagementandpower

Provideenhancedsystemavailabilityandcontinuityofoperations

•IEEE802.1sMultipleSpanningTreeProtocol

ProvideshighlinkavailabilityinmultipleVLANenvironmentsbyallowingmultiplespanningtrees;encompassesIEEE802.1DSpanningTreeProtocolandIEEE802.1wRapidSpanningTreeProtocol

•IEEE802.3adLinkAggregationControlProtocol(LACP)andHPEporttrunking

Supportupto144trunks,eachwithuptoeightlinks(ports)pertrunk

•Distributedtrunking

Enablesloop-freeandredundantnetworktopologywithoutusingSpanningTreeProtocol;allowsaserverorswitchtoconnecttotwoswitchesusingonelogicaltrunkforredundancyandloadsharing

•Optionalredundantpowersupply

Providesuninterruptedpowerandallowshot-swappingoftheredundantpowersupplieswheninstalled

•Hot-swappablemodules

Allowsdissimilarmodules,andpowersuppliesinaredundantpowersupplyconfigurationtobeaddedorswappedwithoutinterruptingthenetwork

•Sparingsimplicity

HPEzl-commonaccessories(interfacemodulesandpowersupplies)

Page 7Data sheet

•UplinkFailureDetection

Providesactive-standbynetworkpathredundancyforserversthatareconfiguredforactive-standbyNICteaming

•SmartLink

Provideseasy-to-configurelinkredundancyofactiveandstandbylinks

Layer 2 switching•VLANsupportandtagging

SupportstheIEEE802.1Qstandardand4,094VLANssimultaneously

•IEEE802.1vprotocolVLANs

Isolateselectnon-IPv4protocolsautomaticallyintotheirownVLANs

•VxLAN

Encapsulation(tunneling)protocolforoverlaynetworkthatenablesamorescalablevirtualnetworkdeployment(requiresv3modules)

•GVRPandMVRP

AllowsautomaticlearninganddynamicassignmentofVLANs

•IEEE802.1adQ-in-Q

IncreasesthescalabilityofanEthernetnetworkbyprovidingahierarchicalstructure;connectsmultipleLANsonahigh-speedcampusormetronetwork

•MAC-basedVLAN

Providesgranularcontrolandsecurity;usesRADIUStomapaMACaddress/usertospecificVLANs(requiresv2orhighermodules)

•RapidPer-VLANSpanningTree(RPVST+)

AllowseachVLANtobuildaseparatespanningtreetoimprovelinkbandwidthusage;iscompatiblewithPVST+

•HPEswitchmeshing

Dynamicallyloadbalancesacrossmultipleactiveredundantlinkstoincreaseavailableaggregatebandwidth;allowsconcurrentLayer3routingwithv2orhighermodules

Layer 3 services•BidirectionalForwardingDetection(BFD)

EnableslinkconnectivitymonitoringandreducesnetworkconvergencetimeforOSPFv2andVRRP(requiresv3modules)

•UserDatagramProtocol(UDP)helperfunction

AllowsUDPbroadcaststobedirectedacrossrouterinterfacestospecificIPunicastorsubnetbroadcastaddressesandpreventsserverspoofingforUDPservicessuchasDHCP

Page 8Data sheet

•Loopbackinterfaceaddress

DefinesanaddressinRoutingInformationProtocol(RIP)andOpenStandardPathFirst(OSPF),improvingdiagnosticcapability

•Routemaps

Providemorecontrolduringrouteredistribution;allowfilteringandalteringofroutemetrics

•DHCPserver

CentralizesandreducesthecostofIPv4addressmanagement

Layer 3 routing•StaticIProuting

ProvidesmanuallyconfiguredroutingforbothIPv4andIPv6networks

•RoutingInformationProtocol(RIP)

ProvidesRIPv1,RIPv2,andRIPngrouting

•OSPF

ProvidesOSPFv2forIPv4routingandOSPFv3forIPv6routing

•Policy-basedrouting

Usesaclassifiertoselecttrafficthatcanbeforwardedbasedonpolicysetbythenetworkadministrator(requiresv2orhighermodules)

•BorderGatewayProtocol(BGP)

ProvidesIPv4BorderGatewayProtocolrouting,whichisscalable,robust,andflexible

Security•Accesscontrollists(ACLs)

ProvidefilteringbasedontheIPfield,source/destinationIPaddress/subnet,andsource/destinationTCP/UDPportnumberonaper-VLANorper-portbasis

•Multipleuserauthenticationmethods

– IEEE802.1Xusersperport

providesauthenticationofmultipleIEEE802.1Xusersperport

–Web-basedauthentication

authenticatesfromawebbrowserforclientsthatdonotsupportIEEE802.1Xsupplicant

–MAC-basedauthentication

clientisauthenticatedwiththeRADIUSserverbasedontheclient’sMACaddress

–ConcurrentIEEE802.1X,web,andMACauthenticationschemesperport

switchportacceptsupto32sessionsofIEEE802.1X,web,andMACauthentications

Page 9Data sheet

•PrivateVLAN

Providesnetworksecuritybyrestrictingpeer-to-peercommunicationtopreventavarietyofmaliciousattacks;typicallyaswitchportcanonlycommunicatewithotherportsinthesamecommunityand/oranuplinkport,regardlessofVLANIDordestinationMACaddress

•DHCPprotection

BlocksDHCPpacketsfromunauthorizedDHCPservers,preventingdenial-of-serviceattacks

•Securemanagementaccess

Deliverssecureencryptionofallaccessmethods(CLI,GUI,orMIB)throughSSHv2,SSL,and/orSNMPv3

•SwitchCPUprotection

Providesautomaticprotectionagainstmaliciousnetworktraffictryingtoshutdowntheswitch

•ICMPthrottling

DefeatsICMPdenial-of-serviceattacksbyenablinganyswitchporttoautomaticallythrottleICMPtraffic

•Identity-drivenACL

EnablesimplementationofahighlygranularandflexibleaccesssecuritypolicyandVLANassignmentspecifictoeachauthenticatednetworkuser

•STPBPDUportprotection

BlocksBridgeProtocolDataUnits(BPDUs)onportsthatdonotrequireBPDUs,preventingforgedBPDUattacks

•DynamicIPlockdown

WorkswithDHCPprotectiontoblocktrafficfromunauthorizedhosts,preventingIPsourceaddressspoofing

•DynamicARPprotection

BlocksARPbroadcastsfromunauthorizedhosts,preventingeavesdroppingortheftofnetworkdata

•STProotguard

Protectstherootbridgefrommaliciousattacksorconfigurationmistakes

Page 10Data sheet

•Detectionofmaliciousattacks

Monitors10typesofnetworktrafficandsendsawarningwhenananomalythatpotentiallycanbecausedbymaliciousattacksisdetected

•Portsecurity

AllowsaccessonlytospecifiedMACaddresses,whichcanbelearnedorspecifiedbytheadministrator

•MACaddresslockout

PreventsparticularconfiguredMACaddressesfromconnectingtothenetwork

•Source-portfiltering

Allowsonlyspecifiedportstocommunicatewitheachother

•RADIUS/TACACS+

Easesswitchmanagementsecurityadministrationbyusingapasswordauthenticationserver

•SecureShell

EncryptsalltransmitteddataforsecureremoteCLIaccessoverIPnetworks

•SecureSocketsLayer(SSL)

EncryptsallHTTPtraffic,allowingsecureaccesstothebrowser-basedmanagementGUIintheswitch

•SecureFTP

Allowssecurefiletransfertoandfromtheswitch;protectsagainstunwantedfiledownloadsorunauthorizedcopyingofaswitchconfigurationfile

•ManagementInterfaceWizard

HelpssecuremanagementinterfacessuchasSNMP,telnet,SSH,SSL,web,andUSBatthedesiredlevel

•Switchmanagementlogonsecurity

HelpssecureswitchCLIlogonbyoptionallyrequiringeitherRADIUSorTACACS+authentication

•Securitybanner

Displaysacustomizedsecuritypolicywhenuserslogintotheswitch

•IEEE802.1AEMACsec

Providessecurityonalinkbetweentwoswitchports(1Gbpsor10Gbps)usingstandardencryptionandauthentication(requiresv3modules)

Page 11Data sheet

Convergence•IPmulticastrouting

IncludesPIMSparseandDensemodestorouteIPmulticasttraffic

•IPmulticastsnooping(data-drivenIGMP)

PreventsfloodingofIPmulticasttraffic

•LLDP-MED(MediaEndpointDiscovery)

DefinesastandardextensionofLLDPthatstoresvaluesforparameterssuchasQoSandVLANtoautomaticallyconfigurenetworkdevicessuchasIPphones

•PoEallocations

Supportsmultiplemethods(automatic,IEEE802.3afclass,LLDP-MED,oruser-specified)toallocatePoEpowerformoreefficientenergysavings

•AutoVLANconfigurationforvoice

–RADIUSVLAN

usesastandardRADIUSattributeandLLDP-MEDtoautomaticallyconfigureaVLANforIPphones

–CDPv2

usesCDPv2toconfigurelegacyIPphones

•LocalMACAuthentication

AssignsattributessuchasVLANandQoSusinglocallyconfiguredprofilethatcanbealistofMACprefixes

Warranty and support •LimitedLifetimeWarranty

Seehpe.com/networking/warrantysummaryforwarrantyandsupportinformationincludedwithyourproductpurchase.

•Softwarereleases

Tofindsoftwareforyourproduct,refertohpe.com/networking/support;fordetailsonthesoftwarereleasesavailablewithyourproductpurchase,refertohpe.com/networking/warrantysummary.

Page 12Data sheet

HPE 5400R zl2 Switch Series

Specifications

HPE 5406R zl2 Switch (J9821A) HPE 5412R zl2 Switch (J9822A) HPE 5406R-44G-PoE+/2SFP+ (No PSU) v2 zl2 Switch (J9823A)

Included accessories 1HPE5400Rzl2ManagementModule(J9827A)1HPE5406Rzl2SwitchFanTray(J9831A)

1HPE5400Rzl2ManagementModule(J9827A)1HPE5412Rzl2SwitchFanTray(J9832A)

1HPE5400Rzl2ManagementModule(J9827A)1HPE5406Rzl2SwitchFanTray(J9831A)1HPE24-portGig-TPoE+v2zlModule(J9534A)1HPE20-portGig-TPoE+/2-port10GbESFP+v2zlModule(J9536A)

I/O ports and slots 6openmoduleslotsSupportsamaximumof144autosensing10/100/1000portsor144SFPportsor48SFP+portsor48HPESmartRateMulti-Gigabitor12 40GbEports,oracombination

12openmoduleslotsSupportsamaximumof288autosensing10/100/1000portsor288SFPportsor96SFP+portsor96HPESmartRateMulti-Gigabitor24 40GbEports,oracombination

44RJ-45autosensing10/100/1000PoE+ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T,IEEE802.3atPoE+);MediaType:Auto-MDIX;Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly2open10GbESFP+transceiverslots4openmoduleslotsSupportsamaximumof144autosensing10/100/1000portsor144SFPportsor48SFP+portsor48HPESmartRateMulti-Gigabitor12 40GbEports,oracombination

Power supplies 2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

4powersupplyslots2minimumpowersuppliesrequired(orderedseparately)

2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

Fan tray Includes:1xJ9831A1fantrayslot

Includes:1xJ9832A1fantrayslot

Includes:1xJ9831A1fantrayslot

Physical characteristics Dimensions

Weight

17.5(w)x17.75(d)x6.9(h)in.(44.45x45.09x17.53cm)(4Uheight)24.5lb(11.11kg)

17.5(w)x17.75(d)x12.1(h)in.(44.45x45.09x30.73cm)(7Uheight)38.1lb(17.28kg)

17.5(w)x17.75(d)x6.9(h)in.(44.45x45.09x17.53cm)(4Uheight)28.11lb(12.75kg)

Memory and processor v3GigabitModule

v2GigabitModule

v3 10GModule

v2 10GModule

v3 40GModule

ManagementModule

DualARM®CoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM

DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM

DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM

Page 13Data sheet

HPE 5406R zl2 Switch (J9821A) HPE 5412R zl2 Switch (J9822A) HPE 5406R-44G-PoE+/2SFP+ (No PSU) v2 zl2 Switch (J9823A)

Mounting and enclosure MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly

MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly

MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly

Performance1000MbLatency10GbpsLatency40GbpsLatencyThroughputRouting/SwitchingcapacitySwitchfabricspeedRoutingtablesize

MACaddresstablesize

IPv6ReadyCertified<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)Upto571.4Mpps960Gbps1015Gbps10000entries(IPv4),5000entries(IPv6)

64000entries

IPv6ReadyCertified<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)Upto1142.8Mpps1920Gbps2030Gbps10000entries(IPv4),5000entries(IPv6)

64000entries

IPv6ReadyCertified<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)Upto571.4Mpps960Gbps1015Gbps10000entries(IPv4),5000entries(IPv6)

64000entries

EnvironmentOperatingtemperature

OperatingrelativehumidityNonoperating/StoragetemperatureNonoperating/StoragerelativehumidityAltitudeAcoustic

32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:44dB,Pressure:31.7dBISO7779,ISO9296

32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:49dB,Pressure:35.7dBISO7779,ISO9296

32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:44dB,Pressure:31.7dBISO7779,ISO9296

Electrical characteristicsFrequency80plus.orgCertificationDescription

Maximumheatdissipation

Voltage

Notes

50/60HzGoldDoesnotcomewithpowersupply.Twopowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.2450BTU/hr(2584kJ/hr),(max.non-PoE);3700BTU/hr(3903kJ/hr),(max.usingPoE)100–127/200–240VAC,rated(Powersupplydependent)

HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.Whenmorethanfourpowercordsareinstalledina5412Rzl2switchchassis,additionalinstallationrequirementsareneeded.RefertotheHPE5400Rzl2SwitchesQuickSetupGuideandSafety/RegulatoryInformationmanualfordetails.

50/60HzGoldDoesnotcomewithpowersupply.Fourpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.4900BTU/hr(5169kJ/hr),(max.non-PoE);7400BTU/hr(7,807kJ/hr),(max.usingPoE)100–127/200–240VAC,rated(Powersupplydependent)

HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.Whenmorethanfourpowercordsareinstalledina5412Rzl2switchchassis,additionalinstallationrequirementsareneeded.RefertotheHPE5400Rzl2SwitchesQuickSetupGuideandSafety/RegulatoryInformationmanualfordetails.

50/60HzGoldDoesnotcomewithpowersupply.Twoopenpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.2450BTU/hr(2584.75kJ/hr),(max.non-PoE);3700BTU/hr(3903kJ/hr),(max.usingPoE)110–127/200–240VAC,rated(Powersupplydependent)

HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.Whenmorethanfourpowercordsareinstalledina5412Rzl2switchchassis,additionalinstallationrequirementsareneeded.RefertotheHPE5400Rzl2SwitchesQuickSetupGuideandSafety/RegulatoryInformationmanualfordetails.

Page 14Data sheet

HPE 5406R zl2 Switch (J9821A) HPE 5412R zl2 Switch (J9822A) HPE 5406R-44G-PoE+/2SFP+ (No PSU) v2 zl2 Switch (J9823A)

Safety CSA22.2No.60950;UL60950;IEC60950;EN60950

CSA22.2No.60950;UL60950;IEC60950;EN60950

CSA22.2No.60950;UL60950;IEC60950;EN60950

Emissions FCCpart15ClassA;EN55022/CISPR22ClassA

FCCpart15ClassA;EN55022/CISPR22ClassA

FCCpart15ClassA;EN55022/CISPR22ClassA

ImmunityENESD

RadiatedEFT/Burst

SurgeConductedPowerfrequencymagneticfield

HarmonicsFlicker

EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3

EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3

EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3

Management IMC—IntelligentManagementCenter;Command-lineinterface;webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement

IMC—IntelligentManagementCenter;Command-lineinterface;webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement

IMC—IntelligentManagementCenter;Command-lineinterface;webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement

Notes Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;forexample,J9142B,J8177C)

Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;forexample,J9142B,J8177C)

Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;forexample,J9142B,J8177C)

Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/services fordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

Page 15Data sheet

HPE 5400R zl2 Switch Series

Specifications (continued)

HPE 5412R-92G-PoE+/2SFP+ (No PSU) v2 zl2 Switch (J9825A)

HPE 5406R-44G-PoE+/4SFP (No PSU) v2 zl2 Switch (J9824A)

HPE 5412R-92G-PoE+/4SFP (No PSU) v2 zl2 Switch (J9826A)

Included accessories 1HPE5400Rzl2ManagementModule(J9827A)1HPE5412Rzl2SwitchFanTray(J9832A)3HPE24-portGig-TPoE+v2zlModule(J9534A)1HPE20-portGig-TPoE+/2-port10GbESFP+v2zlModule(J9536A)

1HPE5400Rzl2ManagementModule(J9827A)1HPE5406Rzl2SwitchFanTray(J9831A)1HPE24-portGig-TPoE+v2zlModule(J9534A)1HPE20-portGig-TPoE+/4-portSFPv2zlModule(J9535A)

1HPE5400Rzl2ManagementModule(J9827A)1HPE5412Rzl2SwitchFanTray(J9832A)3HPE24-portGig-TPoE+v2zlModule(J9534A)1HPE20-portGig-TPoE+/4-portSFPv2zlModule(J9535A)

I/O ports and slots 92RJ-45autosensing10/100/1000PoE+ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T,IEEE802.3atPoE+);MediaType:Auto-MDIX;Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly2open10GbESFP+transceiverslots8openmoduleslotsSupportsamaximumof288autosensing10/100/1000portsor288SFPportsor96SFP+portsor96HPESmartRateMulti-Gigabitor24 40GbEports,oracombination

44RJ-45autosensing10/100/1000ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T);MediaType:Auto-MDIX;Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly4openmini-GBIC(SFP)slots4openmoduleslotsSupportsamaximumof144autosensing10/100/1000portsor144SFPportsor48SFP+portsor48HPESmartRateMulti-Gigabitor12 40GbEports,oracombination

92RJ-45autosensing10/100/1000PoE+ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T,IEEE802.3atPoE+);MediaType:Auto-MDIX;Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly4openmini-GBIC(SFP)slots8openmoduleslotsSupportsamaximumof288autosensing10/100/1000portsor288SFPportsor96SFP+portsor96HPESmartRateMulti-Gigabitor24 40GbEports,oracombination

Power supplies 4powersupplyslots2minimumpowersuppliesrequired(orderedseparately)

2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

4powersupplyslots2minimumpowersuppliesrequired(orderedseparately)

Fan tray Includes:1xJ9832A1fantrayslot

Includes:1xJ9831A1fantrayslot

Includes:1xJ9832A1fantrayslot

Physical characteristicsDimensions

Weight

17.5(w)x17.75(d)x12.1(h)in.(44.45x45.09x30.73cm)(7Uheight)45.19lb(20.5kg)

17.5(w)x17.75(d)x6.9(h)in.(44.45x45.09x17.53cm)(4Uheight)26.19lb(11.88kg)

17.5(w)x17.75(d)x12.1(h)in.(44.45x45.09x30.73cm)(7Uheight)45.4lb(20.59kg)

Memory and processorv3GigabitModule

v2GigabitModule

v3 10GModule

v2 10GModule

v3 40GModule

ManagementModule

DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM

DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM

DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM

Page 16Data sheet

HPE 5412R-92G-PoE+/2SFP+ (No PSU) v2 zl2 Switch (J9825A)

HPE 5406R-44G-PoE+/4SFP (No PSU) v2 zl2 Switch (J9824A)

HPE 5412R-92G-PoE+/4SFP (No PSU) v2 zl2 Switch (J9826A)

Mounting and enclosure MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly

MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly

MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly

Performance1000MbLatency10GbpsLatency40GbpsLatencyThroughputRouting/SwitchingcapacitySwitchfabricspeedRoutingtablesizeMACaddresstablesize

IPv6ReadyCertified<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)Upto1142.8Mpps1920Gbps2030Gbps10000entries(IPv4),5000entries(IPv6)64000entries

IPv6ReadyCertified<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)Upto571.4Mpps960Gbps1015Gbps10000entries(IPv4),5000entries(IPv6)64000entries

IPv6ReadyCertified<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)Upto1142.8Mpps1920Gbps2030Gbps10000entries(IPv4),5000entries(IPv6)64000entries

EnvironmentOperatingtemperature

OperatingrelativehumidityNonoperating/StoragetemperatureNonoperating/StoragerelativehumidityAltitudeAcoustic

32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:49dB,Pressure:35.7dBISO7779,ISO9296

32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:44dB,Pressure:31.7dBISO7779,ISO9296

32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:49dB,Pressure:35.7dBISO7779,ISO9296

Electrical characteristicsFrequency80plus.orgCertificationDescription

Maximumheatdissipation

Voltage

Notes

50/60HzGoldDoesnotcomewithpowersupply.Fouropenpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.4900BTU/hr(5169.5kJ/hr),(max.non-PoE);7400BTU/hr(7807kJ/hr),(max.usingPoE)110–127/200–240VAC,rated(Powersupplydependent)

HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.Whenmorethanfourpowercordsareinstalledina5412Rzl2switchchassis,additionalinstallationrequirementsareneeded.RefertotheHPE5400Rzl2SwitchesQuickSetupGuideandSafety/RegulatoryInformationmanualfordetails.

50/60HzGoldDoesnotcomewithpowersupply.Twoopenpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.2450BTU/hr(2584.75kJ/hr),(max.non-PoE);3700BTU/hr(3903kJ/hr),(max.usingPoE)110–127/200–240VAC,rated(Powersupplydependent)

HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.Whenmorethanfourpowercordsareinstalledina5412Rzl2switchchassis,additionalinstallationrequirementsareneeded.RefertotheHPE5400Rzl2SwitchesQuickSetupGuideandSafety/RegulatoryInformationmanualfordetails.

50/60HzGoldDoesnotcomewithpowersupply.Fouropenpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.4900BTU/hr(5169.5kJ/hr),(max.non-PoE);7400BTU/hr(7807kJ/hr),(max.usingPoE)110–127/200–240VAC,rated(Powersupplydependent)

HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.Whenmorethanfourpowercordsareinstalledina5412Rzl2switchchassis,additionalinstallationrequirementsareneeded.RefertotheHPE5400Rzl2SwitchesQuickSetupGuideandSafety/RegulatoryInformationmanualfordetails.

Page 17Data sheet

HPE 5412R-92G-PoE+/2SFP+ (No PSU) v2 zl2 Switch (J9825A)

HPE 5406R-44G-PoE+/4SFP (No PSU) v2 zl2 Switch (J9824A)

HPE 5412R-92G-PoE+/4SFP (No PSU) v2 zl2 Switch (J9826A)

Safety CSA22.2No.60950;UL60950;IEC60950;EN60950

CSA22.2No.60950;UL60950;IEC60950;EN60950

CSA22.2No.60950;UL60950;IEC60950;EN60950

Emissions FCCpart15ClassA;EN55022/CISPR22ClassA

FCCpart15ClassA;EN55022/CISPR22ClassA

FCCpart15ClassA;EN55022/CISPR22ClassA

ImmunityENESD

RadiatedEFT/Burst

SurgeConductedPowerfrequencymagneticfield

HarmonicsFlicker

EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3

EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3

EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3

Management IMC—IntelligentManagementCenter;Command-lineinterface;webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement

IMC—IntelligentManagementCenter;Command-lineinterface;webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement

IMC—IntelligentManagementCenter;Command-lineinterface;webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement

Notes Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;forexample,J9142B,J8177C)

Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;forexample,J9142B,J8177C)

Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;forexample,J9142B,J8177C)

Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

Page 18Data sheet

HPE 5400R zl2 Switch Series

Specifications (continued)

HPE 5406R-8XGT/8SFP+ (No PSU) v2 zl2 Switch (J9868A)

HPE 5412R 92GT PoE+/4SFP+ (No PSU) v3 zl2 Switch (JL001A)

HPE 5406R 8-port 1/2.5/5/10GBASE-T PoE+/8-port SFP+ (No PSU) v3 zl2 Switch (JL002A)

Included accessories 1HPE5400Rzl2ManagementModule(J9827A)1HPE5406Rzl2SwitchFanTray(J9831A)1HPE8-port10GbESFP+v2zlModule(J9538A)1HPE8-port10GBASE-Tv2zlModule(J9546A)

1HPE5400Rzl2ManagementModule(J9827A)1HPE5412Rzl2SwitchFanTray(J9832A)3HPE24-port10/100/1000BASE-TPoE+MACsecv3zl2Module(J9986A)1HPE20-port10/100/1000BASE-TPoE+/4-port1G/10GbESFP+MACsecv3zl2Module(J9990A)

1HPE5400Rzl2ManagementModule(J9827A)1HPE5406Rzl2SwitchFanTray(J9831A)1HPE8-port1G/10GbESFP+MACsecv3zl2Module(J9993A)1HPE8-port1/2.5/5/10GBASE-TPoE+MACsecv3zl2Module(J9995A)

I/O ports and slots 8RJ-45 10GbEports(IEEE802.3an-2006Type10GBASE-T)8open10GbESFP+transceiverslots4openmoduleslotsSupportsamaximumof144autosensing10/100/1000portsor144SFPportsor48SFP+portsor48HPESmartRateMulti-Gigabitor12 40GbEports,oracombination

92RJ-45autosensing10/100/1000PoE+ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T,IEEE802.3atPoE+);MediaType:Auto-MDIX;Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly4open10GbESFP+transceiverslots8openmoduleslotsSupportsamaximumof288autosensing10/100/1000portsor288SFPportsor96SFP+portsor96HPESmartRateMulti-Gigabitor24 40GbEports,oracombination

8RJ-45HPESmartRateMulti-Gigabitports8open10GbESFP+transceiverslots4openmoduleslotsSupportsamaximumof144autosensing10/100/1000portsor144SFPportsor48SFP+portsor48HPESmartRateMulti-Gigabitor12 40GbEports,oracombination

Power supplies 2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

4powersupplyslots2minimumpowersuppliesrequired(orderedseparately)

2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

Fan tray Includes:1xJ9831A1fantrayslot

Includes:1xJ9832A1fantrayslot

Includes:1xJ9831A1fantrayslot

Physical characteristicsDimensions

Weight

17.5(w)x17.75(d)x6.9(h)in.(44.45x45.09x17.53cm)(4Uheight)28.11lb(12.75kg)

17.5(w)x17.75(d)x12.1(h)in.(44.45x45.09x30.73cm)(7Uheight)45.19lb(20.5kg)

17.5(w)x17.75(d)x6.9(h)in.(44.45x45.09x17.53cm)(4Uheight)28.11lb(12.75kg)

Memory and processorv3GigabitModule

v2GigabitModule

v3 10GModule

v2 10GModule

v3 40GModule

ManagementModule

DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM

DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM

DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM

Page 19Data sheet

HPE 5406R-8XGT/8SFP+ (No PSU) v2 zl2 Switch (J9868A)

HPE 5412R 92GT PoE+/4SFP+ (No PSU) v3 zl2 Switch (JL001A)

HPE 5406R 8-port 1/2.5/5/10GBASE-T PoE+/8-port SFP+ (No PSU) v3 zl2 Switch (JL002A)

Mounting and enclosure MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly

MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly

MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly

Performance1000MbLatency10GbpsLatency40GbpsLatencyThroughputRouting/SwitchingcapacitySwitchfabricspeedRoutingtablesizeMACaddresstablesize

IPv6ReadyCertified<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)Upto571.4Mpps960Gbps1015Gbps10000entries(IPv4),5000entries(IPv6)64000entries

IPv6ReadyCertified<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)Upto1142.8Mpps1920Gbps2030Gbps10000entries(IPv4),5000entries(IPv6)64000entries

IPv6ReadyCertified<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)Upto571.4Mpps960Gbps1015Gbps10000entries(IPv4),5000entries(IPv6)64000entries

EnvironmentOperatingtemperature

OperatingrelativehumidityNonoperating/StoragetemperatureNonoperating/StoragerelativehumidityAltitudeAcoustic

32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:44dB,Pressure:31.7dBISO7779,ISO9296

32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:49dB,Pressure:35.7dBISO7779,ISO9296

32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:44dB,Pressure:31.7dBISO7779,ISO9296

Electrical characteristicsFrequency80plus.orgCertificationDescription

Maximumheatdissipation

Voltage

Notes

50/60HzGoldDoesnotcomewithpowersupply.Twoopenpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.2450BTU/hr(2584.75kJ/hr),(max.non-PoE);3700BTU/hr(3903kJ/hr),(max.usingPoE)110–127/200–240VAC,rated(Powersupplydependent)

HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.Whenmorethanfourpowercordsareinstalledina5412Rzl2switchchassis,additionalinstallationrequirementsareneeded.RefertotheHPE5400Rzl2SwitchesQuickSetupGuideandSafety/RegulatoryInformationmanualfordetails.

50/60HzGoldDoesnotcomewithpowersupply.Fouropenpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.4900BTU/hr(5169.5kJ/hr),(max.non-PoE);7400BTU/hr(7807kJ/hr),(max.usingPoE)110–127/200–240VAC,rated(Powersupplydependent)

HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.Whenmorethanfourpowercordsareinstalledina5412Rzl2switchchassis,additionalinstallationrequirementsareneeded.RefertotheHPE5400Rzl2SwitchesQuickSetupGuideandSafety/RegulatoryInformationmanualfordetails.

50/60HzGoldDoesnotcomewithpowersupply.Twoopenpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.2450BTU/hr(2584.75kJ/hr),(max.non-PoE);3700BTU/hr(3903kJ/hr),(max.usingPoE)110–127/200–240VAC,rated(Powersupplydependent)

HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.Whenmorethanfourpowercordsareinstalledina5412Rzl2switchchassis,additionalinstallationrequirementsareneeded.RefertotheHPE5400Rzl2SwitchesQuickSetupGuideandSafety/RegulatoryInformationmanualfordetails.

Page 20Data sheet

HPE 5406R-8XGT/8SFP+ (No PSU) v2 zl2 Switch (J9868A)

HPE 5412R 92GT PoE+/4SFP+ (No PSU) v3 zl2 Switch (JL001A)

HPE 5406R 8-port 1/2.5/5/10GBASE-T PoE+/8-port SFP+ (No PSU) v3 zl2 Switch (JL002A)

Safety CSA22.2No.60950;UL60950;IEC60950;EN60950

CSA22.2No.60950;UL60950;IEC60950;EN60950

CSA22.2No.60950;UL60950;IEC60950;EN60950

Emissions FCCpart15ClassA;EN55022/CISPR22ClassA

FCCpart15ClassA;EN55022/CISPR22ClassA

FCCpart15ClassA;EN55022/CISPR22ClassA

ImmunityENESD

RadiatedEFT/Burst

SurgeConductedPowerfrequencymagneticfield

HarmonicsFlicker

EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3

EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3

EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3

Management IMC—IntelligentManagementCenter;Command-lineinterface;webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement

IMC—IntelligentManagementCenter;Command-lineinterface;webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement

IMC—IntelligentManagementCenter;Command-lineinterface;webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement

Notes Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;forexample,J9142B,J8177C)

Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;forexample,J9142B,J8177C)

Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;forexample,J9142B,J8177C)HPESmartRateMulti-GigabitCabling;1000BASE-T,2.5Gigabit,and5GigabitEthernet:Category5eorbetterUTPorSTP;10GBASE-T:Category6orbetter(CAT6Arecommended)UTPorSTP

Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

Page 21Data sheet

HPE 5400R zl2 Switch Series

Specifications (continued)

HPE 5406R 44GT PoE+/4SFP+ (No PSU) v3 zl2 Switch (JL003A)

HPE 5406R 16-port SFP+ (No PSU) v3 zl2 Switch (JL095A)

Included accessories 1HPE5400Rzl2ManagementModule(J9827A)1HPE5406Rzl2SwitchFanTray(J9831A)1HPE24-port10/100/1000BASE-TPoE+MACsecv3zl2Module(J9986A)1HPE20-port10/100/1000BASE-TPoE+/4-port1G/10GbESFP+MACsecv3zl2Module(J9990A)

1HPE5400Rzl2ManagementModule(J9827A)1HPE5406Rzl2SwitchFanTray(J9831A)2HPE8-port1G/10GbESFP+MACsecv3zl2Module(J9993A)

I/O ports and slots 44RJ-45autosensing10/100/1000PoE+ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T,IEEE802.3atPoE+);MediaType:Auto-MDIX;Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly4open10GbESFP+transceiverslots4openmoduleslotsSupportsamaximumof144autosensing10/100/1000portsor144SFPportsor48SFP+portsor48HPESmartRateMulti-Gigabitor12 40GbEports,oracombination

16open10GbESFP+transceiverslots4openmoduleslotsSupportsamaximumof144autosensing10/100/1000portsor144SFPportsor48SFP+portsor48HPESmartRateMulti-Gigabitor12 40GbEports,oracombination

Power supplies 2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

Fan tray Includes:1xJ9831A1fantrayslot

Includes:1xJ9831A1fantrayslot

Physical characteristicsDimensions

Weight

17.5(w)x17.75(d)x6.9(h)in.(44.45x45.09x17.53cm)(4Uheight)28.11lb(12.75kg)

17.5(w)x17.75(d)x6.9(h)in.(44.45x45.09x17.53cm)(4Uheight)28.11lb(12.75kg)

Memory and processorv3GigabitModule

v2GigabitModulev3 10GModule

v2 10GModulev3 40GModule

ManagementModule

DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM

DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM

Mounting and enclosure MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly

MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly

Page 22Data sheet

HPE 5406R 44GT PoE+/4SFP+ (No PSU) v3 zl2 Switch (JL003A)

HPE 5406R 16-port SFP+ (No PSU) v3 zl2 Switch (JL095A)

Performance1000MbLatency10GbpsLatency40GbpsLatencyThroughputRouting/SwitchingcapacitySwitchfabricspeedRoutingtablesizeMACaddresstablesize

IPv6ReadyCertified<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)Upto571.4Mpps960Gbps1015Gbps10000entries(IPv4),5000entries(IPv6)64000entries

IPv6ReadyCertified<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)Upto571.4Mpps960Gbps1015Gbps10000entries(IPv4),5000entries(IPv6)64000entries

EnvironmentOperatingtemperature

OperatingrelativehumidityNonoperating/StoragetemperatureNonoperating/StoragerelativehumidityAltitudeAcoustic

32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:44dB,Pressure:31.7dBISO7779,ISO9296

32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:44dB,Pressure:31.7dBISO7779,ISO9296

Electrical characteristicsFrequency80plus.orgCertificationDescription

Maximumheatdissipation

Voltage

Notes

50/60HzGoldDoesnotcomewithpowersupply.Twoopenpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.2450BTU/hr(2584.75kJ/hr),(max.non-PoE);3700BTU/hr(3903kJ/hr),(max.usingPoE)110–127/200–240VAC,rated(Powersupplydependent)

HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.Whenmorethanfourpowercordsareinstalledina5412Rzl2switchchassis,additionalinstallationrequirementsareneeded.RefertotheHPE5400Rzl2SwitchesQuickSetupGuideandSafety/RegulatoryInformationmanualfordetails.

50/60HzGoldDoesnotcomewithpowersupply.Twoopenpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.2450BTU/hr(2584.75kJ/hr),(max.non-PoE);3700BTU/hr(3903kJ/hr),(max.usingPoE)110–127/200–240VAC,rated(Powersupplydependent)

HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.Whenmorethanfourpowercordsareinstalledina5412Rzl2switchchassis,additionalinstallationrequirementsareneeded.RefertotheHPE5400Rzl2SwitchesQuickSetupGuideandSafety/RegulatoryInformationmanualfordetails.

Page 23Data sheet

HPE 5406R 44GT PoE+/4SFP+ (No PSU) v3 zl2 Switch (JL003A)

HPE 5406R 16-port SFP+ (No PSU) v3 zl2 Switch (JL095A)

Safety CSA22.2No.60950;UL60950;IEC60950;EN60950 CSA22.2No.60950;UL60950;IEC60950;EN60950

Emissions FCCpart15ClassA;EN55022/CISPR22ClassA FCCpart15ClassA;EN55022/CISPR22ClassA

ImmunityENESDRadiatedEFT/BurstSurgeConductedPowerfrequencymagneticfieldVoltagedipsandinterruptions

HarmonicsFlicker

EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3

EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3

Management IMC–IntelligentManagementCenter;Command-lineinterface;webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement

IMC–IntelligentManagementCenter;Command-lineinterface;webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement

Notes Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;forexample,J9142B,J8177C)

Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;forexample,J9142B,J8177C)

Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

Page 24Data sheet

Standards and Protocols(appliestoallproductsinseries)

BGP RFC1997BGPCommunitiesAttributeRFC2918RouteRefreshCapabilityRFC4271ABorderGatewayProtocol4(BGP-4)

RFC4456BGPRouteReflection:AnAlternativetoFullMeshInternalBGP(IBGP)

RFC5492CapabilitiesAdvertisementwithBGP-4

Device management RFC1591DNS(client) HTMLandtelnetmanagement RFC2576(CoexistencebetweenSNMPv1,v2,v3)RFC2579(SMIv2TextConventions)RFC2580(SMIv2Conformance)RFC3416(SNMPProtocolOperationsv2)RFC3417(SNMPTransportMappings)

General protocols IEEE802.1adQ-in-QIEEE802.1AX-2008LinkAggregationIEEE802.1DMACBridgesIEEE802.1pPriorityIEEE802.1QVLANsIEEE802.1sMultipleSpanningTreesIEEE802.1vVLANclassificationbyProtocolandPortIEEE802.1wRapidReconfigurationofSpanningTreeIEEE802.3adLinkAggregationControlProtocol(LACP)IEEE802.3afPoweroverEthernetIEEE802.3xFlowControl

RFC768UDPRFC783TFTPProtocol(revision2)RFC792ICMPRFC793TCPRFC826ARPRFC854TELNETRFC868TimeProtocolRFC951BOOTPRFC1058RIPv1RFC1350TFTPProtocol(revision2)RFC1519CIDR

RFC1542BOOTPExtensionsRFC1918AddressAllocationforPrivateInternetRFC2030SimpleNetworkTimeProtocol(SNTP)v4RFC2131DHCPRFC2453RIPv2RFC2548(MS-RAS-Vendoronly)RFC3046DHCPRelayAgentInformationOptionRFC3575IANAConsiderationsforRADIUSRFC3576ExttoRADIUS(CoAonly)RFC3768VRRPRFC4675RADIUSVLAN&PriorityUDLD(Uni-DirectionalLinkDetection)RFC5880BFDRFC5905NTPClient

IP multicast RFC3376IGMPv3 RFC3973PIMDenseMode RFC4601PIMSparseMode

IPv6 RFC1981IPv6PathMTUDiscoveryRFC2375IPv6MulticastAddressRFC2080RIPngRFC2081RIPngProtocolApplicabilityRFC2082RIP-2MD5AssignmentsRFC2460IPv6SpecificationRFC2464TransmissionofIPv6overEthernetNetworksRFC2710MulticastListenerDiscovery(MLD)forIPv6RFC2925DefinitionsofManagedObjectsforRemotePing,Traceroute,andLookupOperations(Pingonly)RFC3019MLDv1MIBRFC3315DHCPv6(clientandrelay)RFC3484DefaultAddressSelectionforIPv6

RFC3587IPv6GlobalUnicastAddressFormatRFC3596DNSExtensionforIPv6RFC3810MLDv2forIPv6RFC4022MIBforTCPRFC4087IPTunnelMIBRFC4113MIBforUDPRFC4213BasicTransitionMechanismsforIPv6HostsandRoutersRFC4251SSHv6ArchitectureRFC4252SSHv6AuthenticationRFC4253SSHv6TransportLayerRFC4254SSHv6ConnectionRFC4291IPVersion6AddressingArchitectureRFC4293MIBforIP

RFC4294IPv6NodeRequirementsRFC4419KeyExchangeforSSHRFC4443ICMPv6RFC4541IGMP&MLDSnoopingSwitchRFC4861IPv6NeighborDiscoveryRFC4862IPv6StatelessAddressAuto-configurationRFC5095DeprecationofType0RoutingHeadersinIPv6RFC5340OSPFv3forIPv6RFC5453ReservedIPv6InterfaceIdentifiersRFC5519MulticastGroupMembershipDiscoveryMIB(MLDv2only)RFC5722HandlingofOverlappingIPv6FragmentsRFC6620FCFSSAVIdraft-ietf-savi-mix

Page 25Data sheet

Standards and Protocols (continued) (appliestoallproductsinseries)

MIBs IEEE802.1ap(MSTPandSTPMIB’sonly)IEEE8021-Bridge-MIB(2008)IEEE8021-Q-Bridge-MIB(2008)RFC1155Structure&IDofMgmtInfoforTCP/IPInternetsRFC1213MIBIIRFC1493BridgeMIBRFC1724RIPv2MIBRFC1850OSPFv2MIBRFC2021RMONv2MIBRFC2096IPForwardingTableMIB

RFC2578StructureofManagementInformationVersion2(SMIv2)RFC2613SMONMIBRFC2618RADIUSClientMIBRFC2620RADIUSAccountingMIBRFC2665Ethernet-Like-MIBRFC2668 802.3MAUMIBRFC2674 802.1pandIEEE802.1QBridgeMIBRFC2737EntityMIB(Version2)

RFC2787VRRPMIBRFC2863TheInterfacesGroupMIBRFC2925PingMIBRFC2932IP(MulticastRoutingMIB)RFC2933IGMPMIBRFC4292IPForwardingTableMIBRFC4836ManagedObjectsfor802.3MediumAttachmentUnits(MAU)RFC7331BFDMIB

Network management IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)RFC2819FourgroupsofRMON:1(statistics),2(history),3(alarm),and9(events)

RFC3176sFlowRFC3411SNMPManagementFrameworksRFC3412MessageProcessingandDispatchingfortheSimpleNetworkManagementProtocol(SNMP)RFC3413SimpleNetworkManagementProtocol(SNMP)ApplicationsRFC3414User-basedSecurityModel(USM)forversion3oftheSimpleNetworkManagementProtocol(SNMPv3)RFC3415View-basedAccessControlModel(VACM)fortheSimpleNetworkManagementProtocol(SNMP)RFC3418ManagementInformationBase(MIB)fortheSimpleNetworkManagementProtocol(SNMP)RFC5424SyslogProtocolANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)

SNMPv1/v2c/v3XRMON

OSPF RFC2328OSPFv2 RFC3101OSPFNSSA RFC5340OSPFv3forIPv6

QoS/CoS RFC2474DiffServPrecedence,including8queues/portRFC2475DiffServArchitecture

RFC2597DiffServAssuredForwarding(AF) RFC2598DiffServExpeditedForwarding(EF)

Security IEEE802.1AEMACSecurityStandard(MACsec)IEEE802.1XPortBasedNetworkAccessControlRFC1492TACACS+

RFC1321TheMD5Message-DigestAlgorithmRFC2818HTTPOverTLSRFC2865RADIUS(clientonly)RFC2866RADIUSAccountingRFC3579RADIUSSupportForExtensibleAuthenticationProtocol(EAP)

SecureSocketsLayer(SSL)SSHv2SecureShell

Page 26Data sheet

Modules HPE8-port1/2.5/5/10GBASE-TPoE+MACsecv3zl2Module(J9995A)HPE8-port10GBASE-Tv2zlModule(J9546A)HPE8-port1G/10GbESFP+MACsecv3zl2Module(J9993A)HPE8-port10GbESFP+v2zlModule(J9538A)HPE12-port10/100/1000BASE-TPoE+/12-port1GbESFPMACsecv3zl2Module(J9989A)HPE12-portGig-TPoE+/12-portSFPv2zlModule(J9637A)HPE20-portGig-T/4-portSFPv2zlModule(J9549A)HPE20-portGig-T/2-port10GbESFP+v2zlModule(J9548A)HPE20-port10/100/1000BASE-TPoE+/4-port1G/10GbESFP+MACsecv3zl2Module(J9990A)HPE20-portGig-TPoE+/2-port10GbESFP+v2zlModule(J9536A)HPE20-portGig-TPoE+/4-portSFPv2zlModule(J9535A)HPE20-port10/100/1000BASE-TPoE+/4p1/2.5/5/10GBASE-TPoE+MACsecv3zl2Module(J9991A)HPE20-port10/100/1000BASE-TPoE+MACsec/1-port40GbEQSFP+v3zl2Module(J9992A)HPE24-port10/100PoE+v2zlModule(J9547A)HPE24-port10/100/1000BASE-TMACsecv3zl2Module(J9987A)HPE24-portGig-Tv2zlModule(J9550A)HPE24-port10/100/1000BASE-TPoE+MACsecv3zl2Module(J9986A)HPE24-portGig-TPoE+v2zlModule(J9534A)HPE24-port1GbESFPMACsecv3zl2Module(J9988A)HPE24-portSFPv2zlModule(J9537A)HPE2-port40GbEQSFP+v3zl2Module(J9996A)HPEAdvancedServicesv2zlModulewithHDD(J9857A)HPEAdvancedServicesv2zlModulewithSSD(J9858A)HPE5400Rzl2ManagementModule(J9827A)

Transceivers HPEX111 100MSFPLCFXTransceiver(J9054C)HPEX131 10GX2SCLRTransceiver(J8437A)HPEX132 10GSFP+LCSRTransceiver(J9150A)HPEX132 10GSFP+LCLRTransceiver(J9151A)HPEX132 10GSFP+LCLRMTransceiver(J9152A)HPEX121 1GSFPLCLHTransceiver(J4860C)HPEX121 1GSFPLCSXTransceiver(J4858C)HPEX121 1GSFPLCLXTransceiver(J4859C)HPEX121 1GSFPRJ45TTransceiver(J8177C)HPEX122 1GSFPLCBX-DTransceiver(J9142B)HPEX122 1GSFPLCBX-UTransceiver(J9143B)HPEX132 10GSFP+LCERTransceiver(J9153A)HPEX142 40GQSFP+MPOSR4Transceiver(JH231A)HPEX142 40GQSFP+LCLR4SMTransceiver(JH232A)HPEX142 40GQSFP+MPOeSR4 300MXCVR(JH233A)

HPE 5400R zl2 Switch Series accessories

Page 27Data sheet

Cables HPEX242 10GSFP+toSFP+1mDirectAttachCopperCable(J9281B)HPEX242 10GSFP+toSFP+3mDirectAttachCopperCable(J9283B)HPEX242 10GSFP+toSFP+7mDirectAttachCopperCable(J9285B)HPEX244 10GXFPtoSFP+1mDirectAttachCopperCable(J9300A)HPEX244 10GXFPtoSFP+3mDirectAttachCopperCable(J9301A)HPEX244 10GXFPtoSFP+5mDirectAttachCopperCable(J9302A)HPE0.5mMultimodeOM3LC/LCOpticalCable(AJ833A)HPE1mMultimodeOM3LC/LCOpticalCable(AJ834A)HPE2mMultimodeOM3LC/LCOpticalCable(AJ835A)HPE5mMultimodeOM3LC/LCOpticalCable(AJ836A)HPE15mMultimodeOM3LC/LCOpticalCable(AJ837A)HPE30mMultimodeOM3LC/LCOpticalCable(AJ838A)HPE50mMultimodeOM3LC/LCOpticalCable(AJ839A)HPEPremierFlexLC/LCMulti-modeOM4 2fiber1mCable(QK732A)HPEPremierFlexLC/LCMulti-modeOM4 2fiber2mCable(QK733A)HPEPremierFlexLC/LCMulti-modeOM4 2fiber5mCable(QK734A)HPEPremierFlexLC/LCMulti-modeOM4 2fiber15mCable(QK735A)HPEPremierFlexLC/LCMulti-modeOM4 2fiber30mCable(QK736A)HPEPremierFlexLC/LCMulti-modeOM4 2fiber50mCable(QK737A)HPEX242 40GQSFP+toQSFP+1mDACCable(JH234A)HPEX242 40GQSFP+toQSFP+3mDACCable(JH235A)HPEX242 40GQSFP+toQSFP+5mDACCable(JH236A)

Power supply HPE5400R700WPoE+zl2PowerSupply(J9828A)HPE5400R1100WPoE+zl2PowerSupply(J9829A)HPE5400R2750WPoE+zl2PowerSupply(J9830A)

Mounting kit HPEX450 4U/7UUniversal4-PostRackMountingKit(J9852A)

WLAN HPEMSM775zlPremiumControllerModule(J9840A)

Learnmoreathpe.com/networking

HPE 5400R zl2 Switch Series accessories (continued)

Sign up for updates

Data sheet

©Copyright2014–2016HewlettPackardEnterpriseDevelopmentLP.Theinformationcontainedhereinissubjecttochangewithoutnotice.TheonlywarrantiesforHewlettPackardEnterpriseproductsandservicesaresetforthintheexpresswarrantystatementsaccompanyingsuchproductsandservices.Nothinghereinshouldbeconstruedasconstitutinganadditionalwarranty.HewlettPackardEnterpriseshallnotbeliablefortechnicaloreditorialerrorsoromissionscontainedherein.

ARMisaregisteredtrademarkofARMLimited.SDisatrademarkorregisteredtrademarkofSD-3CintheUnitedStatesandothercountriesorboth.sFlowisaregisteredtrademarkofInMonCorp.Allotherthird-partytrademark(s)is/arethepropertyoftheirrespectiveowner(s).

4AA5-2605ENN,November2016,Rev.6