BC80 Catalogue
c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice
Type Description/Technical Data Stock Code Picture
1
Page
BC80 Catalogue
c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice
Type Description/Technical Data Stock Code Picture
BC80 Catalogue
c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice
Type Description/Technical Data Stock Code Picture
1
1. BC8001 Series Fire Alarm Control Unit.....................................2
BC8001 Compact Control Unit with 1 line (127 Dev) ..................................2
BC8001P Compact Control Unit with 1 line, printer ..........................2
BC8001E Compact Control Unit with 2 line (254 Dev).......................3
BC8001PE Compact Control Unit with 2 line, printer.........................3
2. BDS Series Field Device.............................................................4
BDS051 Optical Smoke Detector.......................................................4
BDS031 Heat Detector (Rate of Rise and Fixed)...............................4
BDS000 Addressable Detector Base.........................................................4
OP520 Collective Optical Smoke Detector.........................................5
HI520 Collective Heat Detector (Rate of Rise and Fixed)..................5
SO520 Collective Detector Base........................................................5
BDS121 Manual Call Point.................................................................6
BDS132 Input Module........................................................................6
BDS221 Output Module......................................................................7
BDS331 Fire Alarm Display Panel......................................................7
BDS161 Collective Input Module........................................................8
BDS152 Isolation Module...................................................................9
3. BC80 Panels and Function Cards.............................................10
BC8013H Wall Mounted Extinguishing Panel...................................10
BCE8001 Extension Card.................................................................11
BC8001 Compact CPU Board...........................................................11
BC8001 Compact Main Board..........................................................11
TP8000 Printer................................................................................12
Table of ContentsPage
BC80 Catalogue
c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice
Type Description/Technical Data Stock Code Picture
2
BC8001 is a control unit very suitable for small size projects
and constructions. It has the following features:
BC8001 Series Fire Alarm Control Unit
BC8001 Compact Control Unit with 1 line(127 Dev) A6C50000016
Number of Detector Lines 1
Number of Field Devices 127
System Network -
Built-in Printer -
LCD Display 240 x 128, Backlit
Auto Mapping Yes
Event History 1000
Digital I/O's
- Nr. Of Dry contacts(24V/3A) 1
- Nr. Of OC outputs 1
- Nr. Of Monitored inputs 2
Operating Voltage 100 ~ 240VAC,
50 ~ 60Hz
Battery-Backup 24V, 6.5Ah
Download/Upload USB
Dimension 370 x 265 x 120mm
Weight(Without Batteries) 3.0kg
One printer (TP8000 thermal sensitive printer) is built in with the
features above.
BC8001P/e BC8001P Compact Control Unit with 1 line, printer A6C50000018
BDS series field devices compatible.
2 Wires and polarity free F-BUS, transmission distance is
up to 1000m.
Specialized BDS algorithm enhance immunity to
environment disturbances.
Menu driven person-machine interface, very easy to operate.
With optional extension card can be networked up to 31
other BC80 control units(BC8001/BC8002/BC8004).
With optional extension card, possible to connect up to 3
B-Bus equipment like interlocking and extinguishing panels.
Optional printer can be mounted in to the control unit.
System can be easily configured on the panel or via PC.
Configuration data can be uploaded to PC at any time.
BC8001/e
BC80 Catalogue
c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice
Type Description/Technical Data Stock Code Picture
3
Same as BC8001, printer and extension card are built in
additionally.
BC8001PE/e
An extension card is built-in additionally in the BC8001 which
can
Interconnect via A-Bus up to 31 controllers
(BC8001/BC8002/BC8004 Control Unit).
Interconnect up to 3 B-BUS equipments(BT8011/12
interlocking panel, BC8013 extinguishing panel).
BC8001E/e A6C50000017
A6C50000019
BC8001E Compact Control Unit with 2 line (254 Dev)
BC8001PE Compact Control Unit with 2 line, printer
BC80 Catalogue
c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice
Type Description/Technical Data Stock Code Picture
4
The BDS051 is smoke detector which can be connected via
F-Bus to BC80 series control unit.
Patented labyrinth optical structure.
New built-in ASIC ensures the high reliability of data
processing.
Homogeneous response to different smoke.
High stability against dust, electromagnetic interference,
temperature fluctuation, humidity and corrosion.
Produced with SMT advanced technology.
BDS Series Field Devices
BDS051 A6C50000002
Operating Voltage 16 ~ 32V DC
Operating Temperature -10 ~ +50 Storage Temperature -25 ~ +75 Relative Humidity 95%(40 2) Quiescent Current 1.0mA Alarm Current 3.0mA EMC 10V/m
Newly developed circuit and sensor ensure high perfor-
mance of fixed and rate-of-rise temperature detection.
High stability against dust, electromagnetic interference,
temperature fluctuation, humidity and corrosion.
Produced with SMT advanced technology.
BDS031 A6C50000001
Operating Voltage 16 ~ 32V DC
Operating Temperature -10 ~ +50Storage Temperature -25 ~ +75Relative Humidity 95%(40 2)Quiescent Current 1.0mAAlarm Current 3.0mAEMC 10V/m
The detector base is for mounting the field devices BDS051
and BDS031.
The detector covers the whole base, the wiring capacity is 1.0
to 1.5 mm2 .
BDS000 A6C50000000
BDS051 Optical Smoke Detector
BDS031 Heat Detector (Rate of Rise and Fixed)
BDS000 Detector Base
BC80 Catalogue
c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice
Type Description/Technical Data Stock Code Picture
The OP520 is an colletive detector can be connected in to S11
system and BC80 system via corresponding collective input
modules.
Patented optical structure and labyrinth.
Homogeneous sensitivity to different smokes.
High stability against dust, electromagnetic interference,
temperature fluctuation, humidity and corrosion.
Manufactured by advanced SMT technology.
Polarity detection and wrong connection fault-free.
5
OP520
BDS Series Field Devices
A6C50000010
Operating Voltage 21~ 29V DC
Output Voltage 5 ~ 13V
Quiescent Current 100 uAOperating Temperature -10 ~ +50Storage Temperature -30 ~ +75Working Humidity 95%(40 2)EMC 10V/m
Alarm Indicator Current 1.5mA
Newly developed circuit and sensor ensure high perfor-
mance of fixed and rate of rise temperature detection.
High stability against dust, electromagnetic interference,
temperature fluctuation, humidity and corrosion.
Produced with SMT advanced technology.
Operating Voltage 21 ~ 29V DC
Output Voltage 5 ~ 13V
Operating Temperature -10 ~ +50Storage Temperature -30 ~ +75Relative Humidity 95%(40 2)Quiescent Current 100 uAAlarm Current 1.5 mAEMC 10V/m
HI520 Collective Heat Detector (Rate- of- Rise and Fixed) A6C50000009
The detector base is for mounting the field devices HI520 and
OP520.
SO520 Collective Detector Base A6C50000011
OP520 Collective Optical Smoke Detector
HI520
SO520
BC80 Catalogue
c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice
Type Description/Technical Data Stock Code Picture
6
Manual call point can immediate trigger a fire alarm by
breaking the glass.
Direct connected on the BDS F-Bus, P,S polarity free.
Installed in the public area such as staircase, elevator
lobby.
Address can be set via Dip-switch.
A built-in dry contact can be used for activating other
equipment.
Mounted on the wall 1.5 meters above the ground.
Delivered electronic part and housing separately.
BDS Series Field Devices
BDS121 Manual Call Point A6C50000003
Operating Voltage 24VDC
Quiescent Current 1mAAlarm Current 3mAWorking Temperature -20 ~ +55Working Humidity 95%(40 2)Capacity of the dry contact 24VDC/ 0.1A
EMC 10V/m
The input module can be a interface to transmit the alarm or
technical signal from other equipment to Fire Alarm Control Unit.
BDS132 Input Module A6C50000004
Operating Voltage 24VDC
Quiescent Current 1mAActivation Current 3mAWorking Temperature -10 ~ +50Relative Humidity 95% (40 2)Wiring Capacity 1.0 ~ 1.5mm2
Connect on the BDS F-Bus directly, address can be set
by a built-in Dip-switch.
Be used for interfacing the signals from flow switch,
pressure switch, etc and other parties to the fire alarm
system.
Input signal has to be a potential free digital signal. The
signal will be transmitted to controller and trigger
corresponding activations by preset logic expressions.
Fault will be automatic detected and displayed on the
controller.
BDS121/e
BDS132/e
BC80 Catalogue
c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice
Type Description/Technical Data Stock Code Picture
The output module is to activate external equipments according
to the preset logic expressions and also expecting to receive a
confirmation of activation.
Connect on the F-Bus directly, address set via Dip-switch.
Can activate external devices by preset logic, the output
can be a pulse or steady signal according to Dip-switch
set up.
On the BDS detection line P , S can be connected with
polarity free.
The input signal is a potential free contact.
Can be used for activating high voltage devices via
connecting ZA2225 and ZA2226 in between.
It is not recommended to use this module for extinguishing
control directly.
Fault will be automatic detected and displayed on the
controller.
Operating Voltage 24VDC
Quiescent Current 1mAActivation Current 3mAWorking Temperature -10 ~ +50Relative Humidity 95% (40 2)Capacity of the output relay AC125V/0.6A, DC24V/2A
Confirmation LED Steady outputSteady ON
Pulse Output Flashing
7
BDS Series Field Devices
BDS221 Output Module A6C50000007
The panel is used for display alarm event on the floor.
1 BDS331 can display information of the devices on the
same F-BUS. Up to 127 devices can be displayed.
Can display fire alarm and control information.
The numbers of devices can be displayed on the LED
display.
Fault will be automatic detected and displayed on the
controller.
An relay output is built-in.
Additional power supply by 24-28VDC, is necessary.
Operating Voltage 24VDC
Monitoring Current 6mAAlarm Current 60mAWorking Temperature -10 ~ +50Working Humidity 95% (40 2)Relay Output 125VAC/1A, 24VDC/1.25A
BDS331/e BDS331 Fire Alarm Display Panel A6C50000008
BDS221/e
BC80 Catalogue
c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice
Type Description/Technical Data Stock Code Picture
8
BDS Series Field Devices
This collective input module can connect collective detectors
to the F-Bus.
Directly connected on the F-Bus, address can be set by
Dip-switch, and the other 2 wires connect the collective
detectors.
Can be connected only in BC80 system.
One BDS161 can connect up to 25 collective detectors,
with the end of line element P6KE18CA.
Can transmit alarm, fault, normal danger level signal to
control unit and has also indication on the module.
On the BDS detection line P, S can be connected with
polarity free.
Collective detector's terminal "1,2 and 3,4 "connected to
BDS161 "D+ and D _ "correspondingly.
Alarm Indicator AI340 and AI300 can be connected on "L+, L_ ".
Fault will be automatic detected and displayed on the
controller.
Alarm Voltage 3.7V ~ 16.4VDC
Fault Voltage(Short) 0V ~ 3.7VDC
Fault Voltage(open) 22.1VDC
Normal Voltage 16.4V ~ 22.1VDC
Quiescent Current 4mAAlarm Current 16mAOperating Voltage -10 ~ +50Working Temperature 95% (40 2)Alarm Indicator 1.5mA
Wiring Capacity 1.0 ~ 1.5mm2
BDS161 Collective Input Module A6C50000006BDS161/e
BC80 Catalogue
c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice
Type Description/Technical Data Stock Code Picture
9
The isolation module is used for isolating the short point on
the detection bus so that the devices which are connected to
the controller before the short point will not be influenced. It
will automatically recover to its normal status when the fault is
eliminated.
In case the short happens on the detection bus, the
isolation module activates so that the devices before the
short point can work normally.
Parallel connection on the first place of each branch or
stub.
No need to set address.
When one loop monitors several floors, on each floor
one Isolation module shall be installed.
One isolation module can connect up to 25 field devices.
P0, S0 on BDS152 connect to control unit P,S terminal
with polarity sensitive. The P,S terminal on BDS152 can
connect to the P,S of other field devices with polarity free.
Fault will be automatic detected and displayed on the
controller.
Working Temperature -20 ~ +50 Working Humidity 95% (40 2) Activation Current 0.5mA Pass through Voltage 1V Wiring Capacity 1.0 ~ 1.5mm2
BDS152/e BDS152 Isolation Module A6C50000005
BDS Series Field Devices
BC80 Catalogue
c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice
Type Description/Technical Data Stock Code Picture
10
BC80 Panels and Function Cards
The extinguishing panel is used for controls of extinguishing
section.
Operating Voltage DC24V ~ 28V
Quiescent Current 40.0mA
Operating Current 200 mA
Nominal Output Current 80mA
Maximum Current per output 200mA
Working Temperature -20 ~ 40
One panel monitors 2 extinguishing section, for each
section 3 outputs and 3 confirmation signals for those
outputs are equipped for activation of extinguishing alert,
extinguishing section separation, gas release.
Can be connected via B-Bus, address set by Dip-switch,
Information of extinguishing section can be displayed on
the control unit.
Parameters can be configured on panel and via PC-Tool.
Can operate the controlled section on site or on the panel.
External control wires are monitored automatically
against the short.
Panel can be set in automatic mode and manual mode.
Auto mapping is possible.
Fault is automatically detected and displayed on the
panel.
BC8013H Wall Mounted Extinguishing Panel A6C50000022BC8013H/e
BC80 Catalogue
c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice
Type Description/Technical Data Stock Code Picture
11
BCC8010 BC8001 Compact CPU Board
Function of the CPU board is storing, loading the configuration
data.
80040600
BCC8001 BC8001 Compact Main Board
Function of the main board is to handle the data and event
received from field.
80010100
BC80 Panels and Function Cards
A-Bus interface can make the compact controller
networkable to 31 controllers.
B-Bus interface can make the controller connect up to 3
B-Bus equipments.
F-Bus interface can connect one detection bus
additionally which can connect up to 127 devices more.
BCE8001 BCE8001 Extension Card
It is the extension card for the BC8001 compact controller.
A6C50000024
BC80 Catalogue
c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice
Type Description/Technical Data Stock Code Picture
12
BC80 Panels and Function Cards
TP8000 TP8000 Printer
A thermal sensitive printer can print out the event on the
logger paper when event occurs.
A6C50000028
BC80 Catalogue
c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice
Type Description/Technical Data Stock Code Picture
BC80 Catalogue
c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice
Type Description/Technical Data Stock Code Picture