Glastender, Inc. • 5400 North Michigan • Saginaw, MI • 48604-9780 • 989.752.4275 • 800.748.0423 • Fax 989.752.4444 • www.glastender.com
A family company manufacturing in the USAwww.glastender.com
beer sysTems Index
Product PageBeer Line Chillers ....................................................... 5.01Line Chiller Racks and Stands .................................... 5.02
Beer Towers Column Towers ....................................................... 5.03 Tee Towers .............................................................. 5.04 Undercounter Towers ............................................. 5.05 Wall Mount Towers ................................................ 5.06 Wood Barrel Towers ............................................... 5.07
Beer SystemsSpec Index
Printed in USASpecifications subject to change without notice. For current specifications please visit our website.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444
www.glastender.com
Approval/Notes:
Project:Item #: Qty:Model #:
AIA#
SIS#
A family company manufacturing in the USAwww.glastender.com
Beer Line Chillers
Rev. 05-16-185.01
1/3 HP Beer Line ChillerModel: BLC-1/3-E
BLC-1/3-E
BLC-1/3-2
1/3, 1/2, and 3/4 HP Beer Line Chillers with Remote Installable Control PanelModels: BLC-1/3, BLC-1/3-2, BLC-1/2, BLC-1/2-2, BLC-3/4, BLC-3/4-2
Standard FeatureS:• Glycol connections with flared fittings for easy service access• Durable black vinyl-clad exterior with 16 gauge galvanized
steel base• Stainless steel, CFC-free, foamed-in-place insulated glycol bath• High efficiency heat exchanger minimizes glycol bath size to
one gallon• Front located glycol filling port
Standard FeatureS:• Control panel is removable and includes wall bracket for
remote installation• Glycol connections with flared fittings for easy service
access• Durable black vinyl-clad exterior with 16 gauge galvanized
steel base• Stainless steel, CFC-free, foamed-in-place insulated glycol
bath• High efficiency heat exchanger minimizes glycol bath size to
one gallon• Front located glycol filling port• Digital temperature control with LCD display• Over-sized condenser coil for maximum efficiency• Clear glycol bath cover for easy visual inspection• Available with two recirculating pumps (designated by “-2”
suffix in model number)BLC-3/4-2
Conforms to ANSI/UL STD 471Certified to CSA STD
C22.2 No. 120
Conforms to ANSI/UL STD 471Certified to CSA STD
C22.2 No. 120
Conforms to ANSI/UL STD 471Certified to CSA STD
C22.2 No. 120
Dimensional Information
5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444 www.glastender.com Printed in USA
Remote Draft Beer Line Chillers
The Glastender exclusive, patented beer line chiller design houses the heat exchanger inside the condensing unit compartment. This unique feature allows the control panel with glycol bath and recirculating pump(s) to be easily installed separate from the condensing unit in a more conveniently accessible location. Simply remove the control panel from the condensing unit cabinet and mount it in the desired location. Only glycol and electrical lines need to be run between the control panel and the condensing unit cabinet.
Glycol return from beer tower to heat exchanger
Glycol line from pump to beer tower
Glycol line from bath to pump
Recirculating pump
.94 gallon glycol bath
Condensing unit andheat exchanger cabinet
Glycol line from heat exchanger to bath
Electrical connection between condensing unit and control
panel by local electrician
Digital temperature control with LCD display
Power cord for unit
Photo shows BLC-1/3 in an installation setting with the control panel installed remotely from the condensing unit cabinet.
Remote Mounted Control Panel Installation Details
Model No. BLC-1/3-E BLC-1/3 BLC-1/3-2 BLC-1/2 BLC-1/2-2 BLC-3/4 BLC-3/4-2Dimensions† Length 27" 27" 27" 27" 27" 27" 27"
Width 21-1/4" 25-5/8" 25-5/8" 25-5/8" 25-5/8" 25-5/8" 25-5/8"Height 14-3/4" 16" 16" 16" 16" 16" 16"† Note: A minimum six inch clearance should be allowed around the entire unit for proper air flow.
Additional clearance should be considered above and in front of the unit for service access.
Electrical Voltage 120V 120V 120V 120V 120V 220V 220VFrequency 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 HzPhase 1ø 1ø 1ø 1ø 1ø 1ø 1øFLA 13 13 18.6 13.5 19.5 10.1 12.9DedicatedCircuit
20A 20A 30A 20A 30A 20A 20A
ElectricalConnection
Cord & PlugNEMA 5-20P
Cord & PlugNEMA 5-20P
Hard Wire Cord & PlugNEMA 5-20P
Hard Wire Cord & PlugNEMA 6-20P
Cord & PlugNEMA 6-20P
Refrigerant R134a R134a R134a R134a R134a R134A R134ARefrigerant Charge 14 oz. 26 oz. 26 oz. 30 oz. 30 oz. 35 oz. 35 oz.Compressor 1/3 HP 1/3 HP 1/3 HP 1/2 HP 1/2 HP 3/4 HP 3/4 HPCapacities* 2,175 BTU/hr 2,175 BTU/hr 2,175 BTU/hr 3,300 BTU/hr 3,300 BTU/hr 6,375 BTU/hr 6,375 BTU/hr
* Note: Rated capacities assume maximum operating ambient temperature of 80°F.Heat Rejection (BTU/hr) 5,323 BTU/hr 5,323 BTU/hr 7,616 BTU/hr 5,527 BTU/hr 7,984 BTU/hr 7,581 BTU/hr 9,683 BTU/hrMax Distance to Taps 125 ft. 125 ft. 125 ft. 250 ft. 250 ft. 400 ft. 400 ft.Circulating Pumps 60 gph 60 gph 60 gph 60 gph 60 gph 60 gph 60 gph
Glycol Bath Capacity .94 gal .94 gal .94 gal .94 gal .94 gal .94 gal .94 gal.Shipping Weight LBS (kg) 128 (58.1) 150 (68.0) 163 (73.9) 153 (69.4) 166 (75.3) 175 (79.5) 193 (87.7)
Printed in USASpecifications subject to change without notice. For current specifications please visit our website.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444
www.glastender.com
Approval/Notes:
Project:Item #: Qty:Model #:
AIA#
SIS#
A family company manufacturing in the USAwww.glastender.com
5.02
Line Chiller Racksand Stands
LCR-GO
LCS-S
Rev 08-07-15
LCR-G, LCR-S, LCR-GE, LCR-SE, LCR-SO, LCR-GO, LCS-G, LCS-S
Standard Features
Line Chiller Rack Product Details
• All 16 gauge galvanized or stainless steel construction• Pre-drilled mounting holes to fit Glastender line chiller
models• Three models of line chiller racks to accommodate various
models of Glastender line chillers• Adjustable feet on line chiller stands for leveling• One line chiller stand fits all models of Glastender line
chillers• Line chiller stands feature bottom shelf for miscellaneous
storage
LCR-GE
Line Chiller Stand Product Details
LCS-S• All 16 gauge stainless steel• Designed for use with all Glastender line chiller models
LCS-G• All 16 gauge galvanized steel• Designed for use with all Glastender line chiller models
LCR-S• All 16 gauge stainless steel• Designed for use with line chiller models BLC-1/3,
BLC-1/3-2, BLC-1/2, and BLC-1/2-2LCR-G• All 16 gauge galvanized steel• Designed for use with line chiller models BLC-1/3,
BLC-1/3-2, BLC-1/2, and BLC-1/2-2LCR-SE• All 16 gauge stainless steel• Designed for use with line chiller model BLC-1/3-E
LCR-GE• All 16 gauge galvanized steel• Designed for use with line chiller models BLC-1/3-E
LCR-SO• All 16 gauge stainless steel• Designed for use with line chiller model LC-47
LCR-GO• All 16 gauge galvanized steel• Designed for use with line chiller model LC-47,
BLC-1/3-2, BLC-1/2, and BLC-1/2-2NOTE: Line chiller racks must be properly mounted to a structural wall.
5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444 www.glastender.com Printed in USA
26 3/8"
1"
1"
7"
26 3/8"
1"
24"3"
38"
1"
7"
38"
3"
24"
FRONT ELEVATION SIDE ELEVATIONPLAN VIEW
ADJUSTABLE LEGS
REAR PLATE TO MOUNT ASSORTED
GAUGES
Line Chiller Racks and Stands
LCR-G and LCR-S
28" 23-1/4"
28"
23-1/4"
13"
FRONT ELEVATIONPLAN VIEW SIDE ELEVATION
MOUNTING HOLES
28" 27"
28"
27"
14"
FRONT ELEVATIONPLAN VIEW SIDE ELEVATION
MOUNTING HOLES
LCR-GE and LCR-SE
LCR-GO and LCR-SO
28"
12"
21-3/8"
28"
21-3/8"
FRONT ELEVATIONPLAN VIEW SIDE ELEVATION
MOUNTING HOLES
LCS-G and LCS-S
Dimensional Information
5.02 - page 2
Printed in USASpecifications subject to change without notice. For current specifications please visit our website.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444
www.glastender.com
Approval/Notes:
Project:Item #: Qty:Model #:
AIA#
SIS#
Standard Features
Specifications
Rev. 11-08-175.03
Drains• Drain pan models - 1/2″ tailpiece
Materials• 20 gauge stainless steel or brass parts include: head,
column, drain pan, and perforated inserts• 16 gauge stainless steel parts include: inner column
stiffener brackets• 16 gauge galvanized steel parts include: base plate
and faucet stiffeners• 11 gauge stainless steel parts include: inner column
base plateShank Sizes• 1/4″ I.D. with 3/16″ fittings
• All stainless steel construction (brass is optional)• Integral surface mount drain pan with lift-out perforated insert• 1/4″ shanks with 3/16″ restriction lines• Available in grainline stainless, mirror finish stainless, or
polished brass• Available with foamed-in-place cold plate assembly for
recirculating system• Available without drain pan (specify suffix ‘-LD’ on the
model number)• Available with one, two, or three faucets• All models include all stainless steel faucets and shanks• Unique internal support system for solid mounting• Base plate serves as template for hole cutting• Available with rinser faucet extension to the left or right
of the drain pan. Specify accessory model number RFSS, RFMF, or RFPB for stainless steel, mirror finish, or polished brass respectively.
CT- -
CT-3-SS
CT-3-SS with optional Rinser Faucet Extension
Size:Specify the number of
faucets from 1 to 3.
Finish:SS = Stainless steelMF = Mirror finishPB = Polished brass
Column Towers
NOTE: Faucet handles not included.
A family company manufacturing in the USAwww.glastender.com
Rinser Faucet Installation Notes
• Important: Unit must be installed in conformance with applicable federal, state, and local plumbing codes, including adequate backflow when required.
• Install in-line water regulator (included).• A separate shut-off valve is recommended
(not included).
03012383Rinser Faucet Assembly
4004503Conforms to NSF/ANSI STD 372
Rinser Faucet (optional)• Accepts 3/8″ cold water lead• 30 psi water pressure regulator included
NOTE: Rinser faucets are not intended for use with towers mounted to a refrigerator due to risk of water line freeze up.
4004503Conforms to NSF/ANSI STD 18
Dimensional Information
5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444 www.glastender.com Printed in USA
Column Towers
NOTE: Faucet handles not included.LD - LESS DRAIN RF - RINSER FAUCET
5-1/8"
5-1/8"
5-1/8"5-1/8"
14" 19"
19"14"
12" 12"
4"
1-1/4"
16-1/8"
4" 4" 4"
17-3/8" 17-3/8"
16-1/8" 17-3/8" 17-3/8"
1-1/4"
1-1/4" 1-1/4"
12"12"
12-3/8"12-3/8"12-1/2"
PLAN VIEWPLAN VIEW PLAN VIEW
FRONT ELEVATION
SIDE ELEVATION SIDE ELEVATION SIDE ELEVATION
FRONT ELEVATION FRONT ELEVATION
Printed in USASpecifications subject to change without notice. For current specifications please visit our website.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444
www.glastender.com
Approval/Notes:
Project:Item #: Qty:Model #:
AIA#
SIS#
Standard Features
Specifications
Rev. 11-08-175.04
BT-10-MFR
• All stainless steel construction (brass is optional)• Integral surface mount drain pan with lift-out perforated insert• 1/4″ shanks with 3/16″ restriction lines• Available in grainline stainless, mirror finish stainless, or
polished brass• Available with insulated cold plate assembly for
recirculating system• Available without drain pan (specify suffix ‘-LD’ on the
model number)• Available in 4, 5, 6, 8, 10, and 12 faucet sizes• All models include all stainless steel faucets and shanks• Foamed-in-place insulated column for extra rigidity• Unique internal support system for solid mounting• Base plate serves as template for hole cutting• Available with rinser faucet extension to the left or right
of the drain pan. Specify accessory model number RFSS, RFMF, or RFPB for stainless steel, mirror finish, or polished brass respectively.
BT- - Finish:
SS = Stainless steelMF = Mirror finishPB = Polished brass
Size:Specify the number of
faucets from 4, 5, 6, 8, 10, 12
Tee Towers
Drains• Drain pan models - 1/2″ tailpiece
Materials• 20 gauge stainless steel or brass parts include: head,
column, drain pan, and perforated inserts• 16 gauge galvanized steel parts include: subsurface head
stiffener and base plate• 11 gauge stainless steel parts include: inner column base
and top plate and tower head mounting plateShank Sizes• 1/4″ I.D. with 3/16″ fittings
BT-5-SSR with optional Rinser Faucet Extension
NOTE: Faucet handles not included.
A family company manufacturing in the USAwww.glastender.com
Rinser Faucet Installation Notes
• Important: Unit must be installed in conformance with applicable federal, state, and local plumbing codes, including adequate backflow when required.
• Install in-line water regulator (included).• A separate shut-off valve is recommended
(not included).
03012383Rinser Faucet Assembly
4004503Conforms to NSF/ANSI STD 372
4004503Conforms to NSF/ANSI STD 18
Rinser Faucet (optional)• Accepts 3/8″ cold water lead• 30 psi water pressure regulator included
NOTE: Rinser faucets are not intended for use with towers mounted to a refrigerator due to risk of water line freeze up.
Dimensional Information
5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444 www.glastender.com Printed in USA
Tee Towers
NOTE: Faucet handles not included.
SINGLE COLUMN TEE TOWERFAUCETS 4 5 6
“A” WIDTH 14″ 17″ 20″
DOUBLE COLUMN TEE TOWERFAUCETS 8 10 12
“B” WIDTH 26″ 32″ 38″
“C” WIDTH 12″ 15″ 18″
TEE TOWER W/RINSER FAUCETSINGLE COLUMN
FAUCETS 4 5 6
“D” WIDTH 14″ 17″ 20″
“E” WIDTH 19″ 22″ 25″
DOUBLE COLUMNFAUCETS 8 10 12
“F” WIDTH 26″ 32″ 38″
“G” WIDTH 31″ 37″ 43″
“H” WIDTH 12″ 15″ 18″
BT FRONT ELEVATION
BT FRONT ELEVATION
BT -LD FRONT ELEVATION
BT -LD SIDE ELEVATION
BT -RF SIDE ELEVATION
BT SIDE ELEVATION
BT -LD FRONT ELEVATION
BT -RF FRONT ELEVATION BT -RF FRONT ELEVATION
BT -LD PLAN VIEW
BT -LD PLAN VIEW
BT -RF PLAN VIEW BT -RF PLAN VIEW
BT PLAN VIEW
BT PLAN VIEW
5"11-7/8"
1-1/4"
4-7/8"
A
5"11-7/8"
4-7/8"
A
11-7/8"
1-1/4"
4-7/8"
5"
B
BC
12"
11-7/8"
4-7/8"
5"
B
BC
5-1/8"
16-3/4"12-1/2"
5-1/8"
A
5-1/8"
F
11-7/8"
1-1/4"
4-7/8"
5"
GH
12"
1/2" DRAIN
18"12-1/2"
5-1/8"
12"
D
5"
11-7/8"
1-1/4"
4-7/8"
E
12"
18"
1/2" DRAIN
12-1/2"
5-1/8"
12"
A
12"
Printed in USASpecifications subject to change without notice. For current specifications please visit our website.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444
www.glastender.com
Approval/Notes:
Project:Item #: Qty:Model #:
AIA#
SIS#
Standard Features
Specifications
Rev. 06-07-165.05
• All stainless steel construction• 1/4″shankswith3/16″restrictionlines• Includes insulated cold plate assembly for recirculating system• Available in 4, 5, 6, 8, 10, and 12 faucet sizes• Includesstainlesssteelfaucetsandshanks
NOTES:1. Undercounter towers do not include a drainpan. Glastender
offers a free standing underbar Beer Drainer, see spec guide page 3.31.
2. Beerandglycollinescanbelocatedtoexitthebackorbottomof the tower - please specify exit location when ordering.
UC- -SSRSize:
Specify the number of faucets from 4, 5, 6, 8, 10, 12
UC-4-SSR
UC-4-SSR shown installed under bar top
UndercounterTowers
Mounting Details
Bar Top
Materials• 20 gauge stainless steel
Shank Sizes• 1/4″I.D.with3/16″fittings
Beer and Glycol Lines• Must specify when ordering if lines are to exit thebackorbottomofthetower
NOTE: Faucet handles not included.
A family company manufacturing in the USAwww.glastender.com
4004503Conforms to NSF/ANSI STD 18
SIDE ELEVATION
FRONT ELEVATION
PLAN VIEW
4 1/4"
4 1/4"
3/4"
A
5 5/8"
5 5/8"
4 7/8"
A
Dimensional Information
5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444 www.glastender.com Printed in USA
Undercounter Towers
4....................... 14" 5....................... 17" 6....................... 20" 8....................... 26"10....................... 32"12....................... 38"
NUMBER OFFAUCETS
“A”WIDTH
UNDERCOUNTERTOWERS
NOTE: Faucet handles not included.
Printed in USASpecifications subject to change without notice. For current specifications please visit our website.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444
www.glastender.com
Approval/Notes:
Project:Item #: Qty:Model #:
AIA#
SIS#
Standard Features
Specifications
Rev. 08-01-165.06
Drains• Drain pan models - 1/2″ tailpiece
Materials• Stainless steel faucets and shanks• Stainless steel body and drain pan• Galvanized steel inner structure on glycol chilled models
Shank Sizes• 1/4″ I.D. with 3/16″ fittings
• All stainless steel construction• Integral drain pan with lift-out perforated inserts• 1/4″ shanks with 3/16″ restriction lines• Available with insulated cold plate assembly for
recirculating system• Available in 4,5,6,8,10, 12 faucet sizes• Includes stainless steel faucets and shanks• Built-in wall mounting bracket• Removable front cover for access to shanks
WT- -SSSize:
Specify the number of faucets from 4,5,6,8,10,12.
WT-6-SS
Wall MountTowers
NOTE: Faucet handles not included.
A family company manufacturing in the USAwww.glastender.com
4004503Conforms to NSF/ANSI STD 18
A
12"
WALL MOUNT TOWERS
NUMBER OFFAUCETS
45681012
"A"WIDTH
14"17"20"26"32"38"
SIDE ELEVATION
FRONT ELEVATION PLAN VIEW
1/2" DRAIN
A
5-11/16"
16"10-7/8"
1-1/4"
16"
Dimensional Information
5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444 www.glastender.com Printed in USA
Wall Mount Towers
NOTE: Faucet handles not included.
Printed in USASpecifications subject to change without notice. For current specifications please visit our website.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444
www.glastender.com
Approval/Notes:
Project:Item #: Qty:Model #:
AIA#
SIS#
A family company manufacturing in the USAwww.glastender.com
Standard Features
Specifications
01-19-185.07
Drains •Drainpanmodels-1/2″tailpieceMaterials • 18gaugestainlesssteelpartsinclude:drainpan andperforateddrainpaninserts
• 20gaugestainlesssteelpartsinclude:innertower head
Shank Sizes • 1/4″I.D.with3/16″fittings
• Oakwoodbarrelconstruction• Includesseparatestainlesssteelsurfacemountdrainpanwithlift-outperforatedinsert
• 1/4″shankswith3/16″restrictionlines• Availableinflatblackornaturalunfinished• Availablewithinsulatedcoldplateassemblyforrecirculatingsystem
• Availableinthreethroughsixfaucetsizes• Includesstainlesssteelfaucetsandshanks• Includeswallmountingbrackets
WB- - Size:
Specifythenumberoffaucetsfrom3to6.
Finish:B = FlatBlackN = Natural
WB-6-B
Wood BarrelTowers
NOTE: Faucet handles not included.
5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444 www.glastender.com Printed in USA
Dimensional InformationWood Barrel Tower
SIDE ELEVATION
FRONT ELEVATION
PLAN VIEW
18"
10-1/2"
18"
8-3/4"
9-1/2"
22-1/4"
21"
14"
22-1/4"
17-1/2"
29"
1/2" DRAIN
1-1/2"
5.07 - page 2
NOTE: Faucet handles not included.