48" OAK
12" OAK
12" OAK
15" OAK
12" OAK
12" OAK
12" OAK
12" OAK12" OAK12" OAK12" OAK
12" OAK12" OAK
15" OAK15" OAK18" OAK
15" MAPLE
24" HACKBERRY36" HACKBERRY
15" HACKBERRY
30" TULIPPOPLAR
FLAG POLE
24" CEDAR
12" TREE
12" TREE
8" TREE 6" TREE 6" TREE
18" OAK
15" OAK
15" OAK
8" MAPLE
BLEACHERS
SUSPENDED
AC UNITSELECTRIC
ROOM
FF=175.75'
18" CRATEMYRTLE
24" CRATEMYRTLE
24" CRATEMYRTLE
18" TREE
BRICKCOLUMNS(TYP.)
6" RCP
6"
VC
P
6" VCP
6"
RC
P
6"
VC
P
6" VCP
JB
PERGOLA
BOLLARDS(TYP.)
CONC
CONC
CONC
CONC
CONC
CONC
CONC
CONC
CONC
TURF
TURF
CONC
CONC
CONC
C 11TH ST SOUTHL
C SERENADE DRIVEL
C S
ER
EN
AD
E D
RIV
EL
ELECTRIC SWITCH PANEL
JB
GASREGULATOR
DEMONSTRATION BUILDING
24" TULIPPOPLAR24" TULIP
POPLAR30" TULIPPOPLAR
31
"x5
1"
RC
AP
23
"x3
6"
RC
AP
6" PVC
18" R
CP
18" RC
P 8"
RC
P
6" P
VC
6" RCP
4" PVC
18
" V
CP
WHEELSTOP (TYP.)
15
" V
CP
15
" V
CP
15" VCP
15" RCP E INV=167.61'15" RCP W INV=168.01'18" RCP S INV=167.61'
15" DIP N INV=169.30''15" RCP S INV=168.60'8" VCP E INV=169.55'8" VCP W INV=169.55'
WROUGHT IRON FENCEWIT BRICK COLUMNS
4" VCP SE INV=173.06'4" VCP SE INV=173.06'6" PVC E INV=173.86'4" PVC W INV=174.21'6" VCP W INV=172.96'4" VCP WSW INV=174.66'
CHILLER PLANT
MARTIN BLDG
ECKFORD BLDG
EAST ROW 11TH ST SOUTH
EAST ROW 11TH ST SOUTH
EAST ROW 11
TH ST SOUTH
PryorMorrow PC
C 2016Copyright
MARK
DATE
DESCRIPTION
SCALE:
Co
lum
bu
s,
Mis
sis
sip
pi
Bu
rea
u o
f B
uild
ing
, G
rou
nd
s a
nd
Re
al P
rop
ert
y M
an
ag
em
en
t
SD
June 1
7, 2016
SC
HE
MA
TIC
DE
SIG
N
DD
Novem
ber
18, 2016
DE
SIG
N D
EV
ELO
PM
EN
T
CD
May 3
1, 2017
75%
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
CD
July
14, 2017
100%
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
OF
FIC
IAL B
ID D
OC
UM
EN
TS
CD
Septe
mber
5, 2017
C0.02SCALE: 1"=20'
COORDINATES SHOWN ARE GRID VALUES, US SURVEY FEETMS STATE PLANE COORDINATES (MS SPC)EAST ZONE, NAD 83 DATUMSCALE FACTOR=0.999968249680
VERTICAL DATUM BASED ON MEAN SEA LEVELNAVD88 DETERMINED BY OPUS SOLUTION
NORTH SHOWN IN GRID NORTHDETERMINED BY GPS OBSERVATIONSCONVERGENCE ANGLE=0° 13' 42.64658727"
THE UNDERGROUND UTILITIES SHOWN HAVE BEENLOCATED FROM FIELD SURVEY INFORMATION AND OTHERSOURCES. THE SURVEYOR MAKES NO GUARANTEE THATTHE UNDERGROUND UTILITIES SHOWN COMPRISE ALLSUCH UTILITIES IN THE AREA, ARE IN SERVICE, OR AREABANDONED. THE SURVEYOR FURTHER DOES NOTWARRANT THAT THE UNDERGROUND UTILITIES SHOWNARE IN THE EXACT LOCATION INDICATED, ALTHOUGH HEDOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY ASPOSSIBLE FROM AVAILABLE INFORMATION. THE SURVEYORHAS NOT PHYSICALLY LOCATED THE UNDERGROUNDUTILITIES.
UTILITIES WARNING:
JAMES BRETT BRASHERP.O. BOX 21002310 MARTIN LUTHER KING JR. DRIVECOLUMBUS, MS. 39704-2100REGISTERED PROFESSIONAL LANDSURVEYOR L.S. NO. 3231STATE OF MISSISSIPPI
General Notes
Property is zoned R-1
Setback Limits
Front: Setback a minimum of not less than twenty-five (25)feet;
Rear: Setback a minimum depth of not less than twenty-five(25) per cent of the depth of the lot, provided such yard need
not exceed twenty-five (25) feet;
Side: On interior lots of seventy-five (75) feet or less in width, atthe building line, there shall be a side yard on each side of a
building having a width of not less than five (5) feet. For lots ofmore than seventy-five (75) feet in width, either of the side
yards may be five (5) feet, and the sum of the side yards shallbe twenty (20) per cent of the lot width, but need not exceed
twenty (20) feet in width.
On corner lots, the side yard regulation shall be the same as forInterior lots except in the case of reversed frontage where thecorner lot rears on the side of a lot facing the other intersectingstreet, in which case there shall be a side yard on the corner lotof not less than fifty (50) per cent of the front required on thelot abutting the rear of the corner lot or separated only by analley. No accessory buildings on a said corner lot shall projectbeyond the front yard line of the lots in the rear, nor shall abuilding be erected, reconstructed, altered or enlarged closer
than five (5) feet to the line of the abutting lot to the rear.
No residential or accessory structure or garage shall be erectedless than twelve and one-half (12½) feet from the property line
abutting a railroad right-of-way line, and a six-foot highprotective fence must be constructed and maintained alongthis line. Said fence must be a physical fence.
Subject property is not located in a Special Flood Hazard Areaas per FEMA Flood Map #28087C0260K with an effective date
of 2/18/2011
CONTACTS AND UTILITY COMPANY INFORMATION
GAS SERVICEATMOS ENERGY 1423 MAIN STREETCOLUMBUS, MS. 39701 662-328-3521
TELEPHONE SERVICEA T & TBUSINESS SALES, BILLINGAND SERVICE 866-620-6000
COLUMBUS LIGHT AND WATER
420 4TH AVENUE SOUTHP.O. BOX 949COLUMBUS, MS 39703-0949 662-243-7440
OHE
FO
GAS
WL
UGE
GAS LINE
FIBER OPTIC
OVERHEAD ELECTRIC
FLOWLINE
WATER LINE
FENCE
EDGE OF GRAVEL
EDGE OF LANDSCAPE
UNDERGROUND ELECTRIC
DRAINAGE PIPE
POWER POLE(WOOD)
LIGHT POLE(WOOD)
GUY WIRE
SIGN
WATER VALVE
FIRE HYDRANT
WATER METER
TREE
GAS METER
GAS VALVE
DOWNSPOUT
SANITARY SEWER MANHOLE
STORM DRAINAGE MANHOLE
COMMUNICATION MANHOLE
LEGEND
HANDICAP PARKING
CLEANOUT
CONTROL POINT
ELECTRIC MANHOLE
SATELLITE DISH
SET IRON PIN
FOUND IRON PIN
BARBED WIRE FENCE
SEWER LINE
LAMP POLE(WOOD)
TELEPHONE PEDESTAL
POWER POLE(METAL)
POWER POLE(CONC.)
LIGHT POLE(METAL)
LIGHT POLE(CONC.)
LAMP POLE(METAL)
LAMP POLE(CONC.)
LAMP POLE(FIBERGLASS)
MAILBOX
GATE POST
BUSH
ELECTRIC BOX
TRAFFIC SIGNAL CONTROLBOX
MONITORING WELL
ELECTRIC METER
IRRIGATION CONTROL VALVE
JUNCTION BOX
UNDERGROUNDCOMMUNICATION
UGC
GAS MARKER
UNDERGROUNDCOMMUNICATIONMARKER
LIGHT
WATER HYDRANT
SPRINKLER HEAD
00 20' 40'
EXISTING CONDITIONS
2017