Centrifugal fan MPA-U
VENTUR tekniska ab, GöteborgManufakturgatan 7ASE-417 07 Göteborg, Sweden
www.ventur.se1 Tel. +46 31-23 50 80Fax +46 31-23 87 98e-mail: [email protected]
General informationMedium-pressure, directly driven fans for industrial applications, offered in 7 sizes from 03 to 350 with flow up to 2381 CFM and static pressure up to 14.8'' w.g. MPA-U blowers are designed for transport of clean and contaminated, non-aggressive and non explosive gases with temperature -4˚F to 176˚F (with surrounding temperature -4˚F to 104˚F)
ConstructionFan in standard is delivered with:
housing made of painted (RAL7042) cast aluminumimpeller provided with straight blades made of aluminum alloy (MPA-U 03 to 290), painted steal (MPA-U 350), dynamically balanced according to ISO 1940-1high efficiency (IE2/IE3), totally enclosed (TEFC) electric motor (460V / 60Hz)made according to IEC standards (frames - from 63 to 132).CCW BH position
Special requestOn request fans can be delivered:
in one of 8 CW and 8 CCW discharge positionswith special paintingwith other than standard voltage supply
ClockwiseUpblast
Rotation and discharge
CW-UB
ClockwiseTop Horizontal
CW-TH
CounterclockwiseUpblast
CCW-UB
CounterclockwiseTop Horizontal
CCW-TH
ClockwiseDownblast
CW-DB
ClockwiesBottom Horizontal
CW-BH
CounterclockwiseDownblast
CCW-DB
CounterclockwiseBottom Horizontal
CCW-BH
Inlet/outlet mounting flanges
Optional accessories
MPA-U 03
MPA-U 25
MPA-U 50
MPA-U 90
MPA-U 160
MPA-U 290
MPA-U 350
Inch:mm:
Inch:mm:
Inch:mm:
Inch:mm:
Inch:mm:
Inch:mm:
Inch:mm:
2 - 5/866.6
2 - 5/866.6
3 - 9/1690.4
4 - 9/16115.8
5 - 9/16141.2
7 - 5/8193.6
7 - 5/8193.6
4 - 9/16115.8
4 - 9/16115.8
4 - 9/16115.8
6 - 9/16166.6
7 - 5/8193.6
8 - 5/8219
8 - 5/8219
Other dimensions available on request.
Fan type D4 (”)
inlet outlet
Inlet / outlet screenScreen made of steel with zinc dedicated for MPA-U series.
Centrifugal fan MPA-U
2VENTUR tekniska ab, StockholmVästberga Allé 1ASE 126 30 Hägersten, Sweden
www.ventur.seTel. +46 8-534 101 90Fax +46 8-534 101 99e-mail: [email protected]
Performance dataAll values are shown for installation type B: ducted outlet, unducted inlet. Fan capacity table is based on the standard air at 70°F and sea level.
MPA-U 03 / MPA-U 25 / MPA-U 50
9
8
7
6
5
4
3
2
1
0
2100
1800
1500
1200
900
600
300
00 10 20 30 40
0 150 300 450 600
CFM x 100
MPA-U 03MPA-U 25
MPA-U 50
m3/h
Stat
ic p
ress
ure
[inch
a w
ater
gau
ge]
Stat
ic p
ress
ure
[Pa]
MPA-U 03
MPA-U 25
MPA-U 50
3440
3440
3440
0.25 BHP
0.18kW
0.25 BHP
0.18kW
0.75 BHP
0.55kW
CFM:
m3/h:
CFM:
m3/h:
CFM:
m3/h:
184
313
222
378
213
362
248
421
147
250
200
340
100
169
173
294
46
77
113
192
358
609
341
579
296
503
222
378
90
153
Model Motorpower
FanRPM
Static PressureInch. w. g.
[Pa]2
4981
2492 1/2623
3747
3 1/2872
4996
4 1/21121
51245
61495
71744
81993
92242
Centrifugal fan MPA-U
VENTUR tekniska ab, GöteborgManufakturgatan 7ASE-417 07 Göteborg, Sweden
www.ventur.se3 Tel. +46 31-23 50 80Fax +46 31-23 87 98e-mail: [email protected]
MPA-U 90
MPA-U 160
MPA-U 290
Performance dataAll values are shown for installation type B: ducted outlet, unducted inlet. Fan capacity table is based on the standard air at 70°F and sea level.
MPA-U 90 / MPA-U 160 / MPA-U 290
14
12
10
8
6
4
2
0
3200
2800
2400
2000
1600
1200
800
400
00 50 100 150 200 250
0 600 1200 1800 2400 3000 3600 4200
CFM x 100
m3/h
Stat
ic p
ress
ure
[inch
a w
ater
gau
ge]
Stat
ic p
ress
ure
[Pa]
MPA-U 90
MPA-U 160
MPA-U 290
3440
3440
3440
1.5 BHP
1.1kW
3 BPH
2.2 kW
5.5 BHP
4 kW
CFM:
m3/h:
CFM:
m3/h:
CFM:
m3/h:
822
1397
1188
2019
1306
2219
1405
2386
746
1268
1084
1842
672
1141
994
1689
2050
3483
621
1056
887
1508
1879
3192
487
828
703
1194
1746
2966
346
587
1663
2825
1584
2690
974
1654
Model Motorpower
FanRPM
Static PressureInch. w. g.
[Pa]2
4981
2493
7474
9965
12456
14957
17448
19939
224210
249112
298913
3238
Centrifugal fan MPA-U
4VENTUR tekniska ab, StockholmVästberga Allé 1ASE 126 30 Hägersten, Sweden
www.ventur.seTel. +46 8-534 101 90Fax +46 8-534 101 99e-mail: [email protected]
MPA-U 350
Performance dataAll values are shown for installation type B: ducted outlet, unducted inlet. Fan capacity table is based on the standard air at 70°F and sea level.
MPA-U 350
16
14
12
10
8
6
4
2
0
3600
3200
2800
2400
2000
1600
1200
800
400
00 50 150100 250200 300
0 600 1200 1800 2400 3000 3600 4200 4800
CFM x 100
m3/h
Stat
ic p
ress
ure
[inch
a w
ater
gau
ge]
Stat
ic p
ress
ure
[Pa]
MPA-U 350 34407.5BHP
5.5kW
CFM:
m3/h:
2165
3678
2286
3884
2347
3987
2031
3451
1913
3251
1816
3085
1722
2926
1593
2706
1368
2324
965
1639
Model Motorpower
FanRPM
Static PressureInch. w. g.
[Pa]5
12454
9966
14957
17448
19939
224210
249111
274012
298913
323814
348715
3736
Centrifugal fan MPA-U
VENTUR tekniska ab, GöteborgManufakturgatan 7ASE-417 07 Göteborg, Sweden
www.ventur.se5 Tel. +46 31-23 50 80Fax +46 31-23 87 98e-mail: [email protected]
Dimensions and weight
MPA-U 03
MPA-U 25
MPA-U 50
MPA-U 90
MPA-U 160
MPA-U 290
MPA-U 350
Inch:
mm:
Inch:
mm:
Inch:
mm:
Inch:
mm:
Inch:
mm:
Inch:
mm:
Inch:
mm:
5,06
128,5
5,06
128,5
6,67
169,5
7,07
179,5
5,91
150
5,91
150
5,91
150
0,75
19
0,75
19
0,79
20
0,79
20
0,79
20
0,79
20
0,79
20
0,47
12
0,47
12
0,51
13
0,51
13
0,51
13
0,51
13
0,51
13
1,16
29,5
1,16
29,5
1,77
45
1,77
45
0,63
16
0,63
16
0,63
16
3,15
80
3,15
80
5,51
140
5,51
140
7,09
180
7,09
180
7,09
180
7,09
180
7,09
180
9,06
230
9,45
240
9,84
250
9,84
250
9,84
250
4,72
120
4,72
120
7,48
190
7,48
190
8,27
210
8,46
215
8,46
215
1,83
46,5
1,83
46,5
2,40
61
3,35
85
4,21
107
5,24
133
5,24
133
7,74
196
7,74
196,5
9,17
233
10,08
256
14,61
371
15,59
396
16,57
421
6,85
174
6,85
174
9,69
246
10,28
261
13,46
342
16,14
410
16,14
410
4,53
115
4,53
115
7,01
178
7,05
179
8,46
215
9,45
240
9,45
240
6,26
159
6,26
159
8,58
218
8,74
222
9,96
253
11,73
298
11,73
298
6,30
160
6,30
160
7,87
200
8,27
210
8,66
220
10,39
264
11,02
280
6,57
167
6,57
167
9,17
233
9,45
240
11,26
286
13,90
353
13,27
337
*dimension can be increased up to 10% depending on used motor
4,53
115
3,74
115
2,56
130
6,30
160
7,87
200
10,24
260
10,24
260
3,74
95
3,74
95
4,41
112
5,31
135
6,61
168
9,06
230
9,06
230
2,56
65
2,56
65
3,15
80
3,94
100
4,92
125
6,69
170
6,69
170
0,39
10
0,39
10
0,43
11
0,43
11
0,47
12
0,51
13
0,51
13
6,50
165
6,50
165
6,50
165
7,87
200
9,84
250
9,65
245
9,65
245
5,47
139
5,47
139
5,47
139
7,17
182
8,66
220
8,54
217
8,54
217
3,94
100
3,94
100
4,21
107
5,43
138
6,69
170
7,09
180
7,09
180
19 lbs
8.5 kg
21 lbs
9.5 kg
33 lbs
15 kg
42 lbs
19 kg
91 lbs
41 kg
122 lbs
55 kg
163 lbs
74 kg
Fan type Fan dimensions
A B C D E F* G H I J K L Ł M d1 d2 d3 d4 d5 d6 d7Fan
weight
MPA-U 160 / MPA-U 290 / MPA-U 350MPA-U 03 / MPA-U 25 / MPA-U 50 / MPA-U 90