+ All Categories
Transcript

Plan ahead• Youmayneedmorethanone

SRLDtoreachsafety.• GrabanotherSRLDassoonas possible.

Know when to change over to a second SRLD

• Whenbreathinggetsuncomfortable:Changeover!

• Whenbreathingbaggetshardtofill:Changeover!

How to change over1 OpensecondSRLD.2 HangsecondSRLDaround neck.3 PullsecondSRLD’sstarter tag.4 Takedeepbreathfrom

first SRLD.Holdbreath.5 Pullsecond SRLD’smouthpiece plug.

6 Spitoutfirstmouthpiece.7 Putsecond SRLD’smouthpiecein mouth.Exhale.

8 Dropfirstnoseclamp.Clampnoseshutwithsecondclamp.

9 DropfirstSRLDaftersecondoneisworking.

Changeover

CSE Corporation600SecoRoad/Monroeville,PA15146www.CSEcorporation.com/412.856.9200

Model SRLD SCSR

Closed-circuit,escape-only,self-containedbreathingapparatusTheserespiratorsareapprovedonlyinthefollowingconfigurations:

Respirator ComponentsTC TC-13F-0645Protection 60min/sc/esc1

Respirator Q152090001000

Cautionsandlimitations JMNOS2

1SC Self-contained

ESC Escape2J Failuretoproperlyuseandmaintainthisproductcould

resultininjuryor death.

M Allapprovedrespiratorsshallbeselected,fitted,used,andmaintainedinaccordancewithMSHA,OSHA,andotherapplicable regulations.

N Neversubstitute,modify,add,oromitparts.Useonlyexactreplacementpartsintheconfigurationasspecifiedbythemanufacturer.

O RefertoUser’sInstructions,and/ormaintenancemanualsforinformationonuseandmaintenanceoftheserespirators.

S SpecialorcriticalUser’sInstructionsand/orspecificuselimitationsapply.RefertoUser’sInstructionsbefore donning.

for full details, ask your foreman or training officer for a copy of the inspection module of the cse scsr products manual.

colors of components shown may vary.

Go slow and steady•Walkwheneveryoucan.•Dropexcessgear.

Speed, heavy loads, and hard work use up oxygen faster.

Making SRLD last longer

Make it a habitDoreadthese

instructions.

DoinspectSRLD daily.

DostoreandcarrySRLDinstandardpouch.

Do practicedonning.

Doknowescapeways.

Doknowwhereaircachesare.

Dotaketrainingseriously.

Don’tstoreSRLDattemperatureswarmerthan150° F.

Don’tstoreoruseSRLDneargas,fuel,flame,heat,or water.

Don’tusefrozen(colderthan32°F)SRLD.GrabanotherSRLD.

Don’tusedamagedSRLD.Notsure?Askyourforeman!

When there’s troubleDoputonSRLDas

soonasyouseeorhear trouble.

Don’twaitforodors.Dangerhasnosmell.

Dospitoutgumor chewingtobacco.

Don’ttwistbreathinghosewhenputtingon SRLD.

Don’tremovemouth-pieceexcepttochange over.

Don’ttalk.Usehand signals.

Doclimb,lift,andstep slowly.

Don’trun.Speed uses up oxygen faster.

Don’tcarrygearyoudon’tneed—onlyanother SRLD.

DochangeovertoanotherSRLDwhenbreathinggetsuncomfortable.

Do’s and don’ts of SRLD safety

KEYindicateshazardous

situationthat,ifnotavoided,willresultindeathorseriousinjury.

indicateshazardoussituationthat,ifnotavoided,couldresultindeathorseriousinjury.

indicateshazardoussituationthat,ifnotavoided,couldresultinminorormoderate injury.

No matter what happens

Don’t use SRLD in firefighting. Will cause death or serious injury.

Don’t use SRLD in rescue work. Will cause death or serious injury.

Special or Critical User InstructionsS

How to do manual start Fill breathing bag1 Clampnose shutwithnose clamp.

2 Takemouthpieceoutof mouth.3 Inhaleonedeepbreath.4 Putmouthpiecebackin mouth.5 Exhaleintomouthpiecetoactivateoxygen.

6 Repeat(Mouthpieceout.Inhale.Mouthpiecein.Exhale.)3to6times,untilbagfills.

Breathing will take some work. You will feel resistance.

7 Keepmouthpieceinmouthandjustkeepbreathing!

Manual start

If starter oxygen escapes thru mouthpieceGo to backup plan!

• GrabanotherSRLD.

Don’ttrytostartabandonedSRLD.

• NootherSRLDhandy?Domanualstart.

Aftermanualstart,SRLDwilltakeseveralminutestoreachfulloxygenproduction.Moveandworkslowlyuntilbreathingbagstaysinflated.ThisproceduredoesnotconformtoCFR42part84requirements.

If you need more than one SRLD straps second

1 Tightenneckstraptotakeweightoffmouthpieceandbreathing hose.

2 Passcheststraparoundyourbackandcliptocheststrap hook.

3 TightencheststrapsoSRLDissnugagainst chest.

move out third1 Puthardhatbackon.2 Dropexcessgear.3 Walk,don’trun,tonextaircacheormine exit.

4 Remembertomoveandworkslowlyuntilbreathingbagstays inflated.

Get ready to move eyes first1 PutSRLDgoggleson.

UseonlystandardSRLD goggles.

2 Needeyeglasses?Wearthemovergoggles.

3 Tuckeyeglasssidepiecesundergogglesstrap.

Don’t panic• Breathedeepandslowtostay calm.

• Headforescapewaysas trained.

Rapid heartbeat and heavy breathing use up oxygen faster.

Size matters•Outofshape?Changeoversoonerthanyourbuddies.

• Justbig?Changeoversoonerthanyourbuddies.

Out-of-shape bodies use up oxygen faster.

Big bodies use up oxygen faster.

Get ready to move

Open your SRLD1 PullSRLDfrompouch.2 SetSRLDonsolid,dry surface.3 RemovehardhatandshinelightonSRLD.

4 Pullopensteelsecurityband:• Locatefabricloopon

SRLD top.• Unclipfabricloop.• Hookfingerthruloop.• HoldSRLDdownwhilepullingloopup.

5 Removesteeltopandbottom covers:• Top:Pullcoveroff.• Bottom:Pullcoveroff.

Eyes first1 PutSRLDgoggleson.

UseonlystandardSRLDgoggles.

2 Needeyeglasses?Wearthemover goggles.

3 Tuckeyeglasssidepiecesundergoggles strap.

Straps second1 Tightenneckstraptotakeweightoffmouthpieceandbreathing hose.

2 Passcheststraparoundyourbackandcliptocheststrap hook.

3 TightencheststrapsoSRLDissnugagainst chest.

Move out third1 Puthardhatback on.2 Keeptheseinstructions.3 Dropexcess gear.4 Walk,don’trun,tonextaircacheormineexit.

Don’tremovemouthpiece,don’ttalk.

Inspect your SRLD before every shift

INST

RUCT

IONS 1 Put it on

and start it Oxygen first1 Loopneckstraparoundnecktofreehands.

◂ Keeppluginmouthpiece.

2 GrabstartertaghangingunderSRLD.

3 Pulldownonceandlet go.

Breathing bag will fill.

Mouthpiece second1 Spitoutgumorchewingtobacco.2 Inhaleonedeepbreath.3 Nowpulloutmouthpieceplug.Don’t twist.

4 Insertmouthpiece.Gripwith teeth.

5 Exhaleintomouthpiecetoactivateoxygen.

Breathing will take some work. You will feel resistance.

6 Justkeepbreathing!

Ifoxygenescapesthrumouthpiece:• Grabanother SRLD.• IfnootherSRLDishandy,beginmanualstart.

Nose clamp third1 Pullclampapart.2 Clampnoseshut.

2 3

Moistureindicator

MFGDate

Moistureindicator

Temperatureindicator

◂ With covers off, you will see breathing bag and other parts.

Return and replace!Notsureaboutanyofthese?

Ask your foreman!

Beenunderwater?Burned?Pouchtootight?

Looseparts?Crookedcover?Puncture?

5yearsold?Moistureindicatorblue?Temperatureindicatorred?

Temperature indicator

Good Bad

Moisture indicator

BadGood


Top Related