Chapter 6 – Physical and Environmental Security
Brian E. Brzezicki
Physical and Environmental Security
Physical security is extremely important. There is no point in technical and administrative security controls if someone can simply bypass them from physically accessing systems.
• Physical security is harder today as systems are more distributed (not just mainframes) and complex.
• Not just about protecting data, but more importantly PEOPLE! (remember safety is always issues #1*)
• Often physical security is an afterthought when building new facilities.
• Lawsuits against companies CAN be filed if a company does not take adequate physical security measures (see next slide)
Some examples of physical problems
• Banks with bushes to close or to high near an ATM. Which allows criminals to hide or blocks view of crimes
• Portion of an underground garage has improper lighting
• Convenience store has too many signs which robbers target because the view is obstructed from the outside.
Threats to physical security
• Natural hazards (floods, tornadoes, fires, temperatures)
• Supply system threats (power outage, water, gas, WAN connection etc)
• Manmade threats (unauthorized access, explosives, damage by disgruntled people, accidents, theft)
• Politically motivated threats (strikes, riots, civil disobedience)
Physical security fundamentals
• Life safety goals* should always be #1 priority
• Like in technical security, defense should be layered which means that different physical controls should work together to accomplish the goal of security.
• Physical security can address all of the CIA fundamental principals.
Planning ProcessThreats should be classified as internal or external.
Risk analysis should be taken on a physical aspect. Assets should be identified, threats should be identified (probabilities calculated) and countermeasures put in place that are COST EFFECTIVE and appropriate to the level of security needed.
Physical security will ultimately be a combination of people, processes, procedures and equipment to protect resources.
(more)
Planning Process
The planning and security program should include the following goals.
• Deterrence – fences, guards, signs• Reducing/Avoiding damage by Delaying attackers –
slow down the attackers (locks, guards, barriers)• Detection – motion sensors, smoke detectors• Incident assessment – response of guards, and
determination of damage level• Response procedures – fire suppression, law
enforcement notification etc
Planning process
Idea is to avoid problems if at all possible, otherwise mitigate problems. This can be best accomplished by layering (which we already talked about). If a crime happens you must be able to detect it, and response should be implemented.
Remember this is the same process that we cover in Rink Analysis! All the same processes and concepts apply.
Target Hardening
Target Hardening ()
Focuses on denying access through physical and artificial barriers. (alarms, locks, fences). Target hardening can lead to restrictions on the use, enjoyment and aesthetics of an environment.
CPTED
An important security concept organizations use is “Crime Prevention Through Environmental Design” – The idea is that proper design of a physical environment can reduce crime by directly affecting human behavior.* It provides guidance in loss and crime prevention through properly facility construction and environmental components and procedures.
CPTED
CPTED concepts have been used since the 1960s and have advanced as environments and crime has advanced. CPTED is not just used for corporate security but also for building neighborhoods etc.
CPTED looks at the components that make up the relationship between humans and their environment.
(some examples CPTED guidelines are next)
CPTED guidelines
Examples• Hedges and planters should not be more than 2.5
feet tall.• Data center should be at the center of a facility.• Street furniture should encourage people to site
and watch what is going around them.• Landscaping should not provide places to hide.• Put CCTV camera in plain view so criminals are
aware they are being watched and recorded.
CPTED
CPTED provides three main strategies to bring together physical environment and social behavior to increase overall protection:
• Natural Access Control
• Natural Surveillance
• Territorial reinforcement
We will talk about these next
CPTED (Natural Access Control)
Natural Access Control – the guidance of people entering and leaving a space by the placement of doors, fences, lighting and landscaping.
• Clear lines of sight and transparency are used to discouraged potential offenders.
• Natural barriers can be used to create physical security zones
CPTED (Natural Surveillance)
Natural Surveillance attempts to discourage criminals by providing many ways for others to observe potential criminal behavior.
CPTED (Territorial Reinforcement)
Creating a space that emphasizes a companies (sphere of influence) so employees feel ownership of that space. The idea is that they will “protect” the environment (report suspicious activities). It can also make criminals feel vulnerable or that they don’t belong there.
Some examples are
(next)
CPTED (Territorial Reinforcement)
• Decorated Walls
• Fences
• Landscaping
• Lights
• Flags
• Company signs
• Decorative sidewalks
• Company “activities” (i.e.. Barbeques)
Good approach to Physical Security
A good approach is to design generically using CPTED and then apply target hardening concepts where appropriate.
Security Zones• Zones are used to physically separate areas
into different security areas.
•Each inner level becomes more restricted and more secure
•Stronger Access Control and Monitoring at the entry point to each zone
Designing a Physical Security Program
When designing a physical security program you must consider the following
• HVAC systems• Construction materials• Power distribution systems• Communications lines• Hazardous materials• Proximity to airports, highways, roads• Proximity to emergency service• etc
FacilitiesWhen building a new facility there are several considerations• Visibility• Surrounding area and external entities
– Crime rate– Proximity to police, medical and fire stations
• Accessibility– Roads/access– Traffic– Proximity to airports etc.
• Natural disasters– Probability of floods, hurricanes– Hazardous terrain (mudslides, falling rocks (really?!?), excessive
snow or rain)
Construction
Different considerations need to be considered when building a facility depending on what the facility is trying to protect and. For example (if documents are stored, fire-resistant materials should be used)
(read the bullet points on 418/419) you should memorize these.
Entry Points
Entry points into a building or control zone must be secured.
• including windows
• Including ventilation ducts etc.
All components of a door should be equally as strong. (no use to have a strong steel door, but weak hinges) (weakest link)
(more)
Doors
• Fire codes dictate that exit bars be on doors.
• Doors can be hollow core or solid core, hollow core doors should only be user internally.
• Doors with automatic locks can be– Fail safe* - what does this mean?– Fail secure* - what does this mean?
Man Trap
WindowsThere are different type of windows that you
should now about• Standard glass – residential home/easily
broken• Tempered glass – glass that is heated and
then suddenly cooled. 5-7x stronger than regular glass
• Acrylic glass (plexiglass/lexan) – stronger than regular glass, but gives off toxic fumes if burnt.
(more)
Windows
• Glass with embedded wires – avoids glass shattering
• Laminated glass – two sheet of glass with a plastic film in between. Harder to break.
• Glass can be treated with films to tint for security.
Computer Room
Computer rooms are where important servers and network equipment is stored.
• Equipment should be placed in locked racks.• Computer rooms should be near the center of the
building, and should be above ground, but not too high that it would be difficult to access by emergency crews
• Strict access control should be enabled.• They should only have 1 access door, though they
might have to have multiple fire doors(more)
Computer Room
• Computer Room should have positive air pressure*
• There should be an easy to access emergency off switch
• Portable fire extinguishers• Smoke/fire sensors should be under raised
floors.• Water sensors should be under raised floors
and on ceilings(more)
Computer Room
• Temperature and Humidity levels should be properly maintained– Humidity too low, static electricity*– Humidity too high, corrosion of metal parts*
• CR should be on separate electrical systems than the rest of the building
• Should have redundant power systems and UPS
Protecting Assets (429)Companies must protect from theft. Theft of laptops is a big
deal especially if private information is on the laptop. You should understand best practices in regards to physically protecting things from being stolen.
• Inventory all laptops including serial number• Harden the OS• Use disk encryption on laptops• Do not check luggage when flying• Never leave a laptop unattended• Install tracking software on laptops (low jack type software)• Password protect the BIOS (See next slide)
(more)
BIOS
BIOS
Protecting Assets
You should also be aware of the types of safes that exist
• Wall safe
• Floor safe
• Chest (stand alone)
• Depositories (safes with slots)
• Vaults (walk in safes)
Internal Support Systems
Power is critically important for data processing we will talk about some different power issues and concerns to be aware off.
Electrical Power Issues
• Electromagnetic Interference – electromagnetic that can create noise. (motors can generate fields)
• Radio Frequency Interference – fluorescent lights
(see next slide for visualization)
Electric power issues
There power interference that stops you from getting “clean power” this is called “line noise”.
Electrical Power IssuesThere are times where the voltage delivered falls
outside normal thresholdsExcess• Spike – momentary high voltage• Surge – prolongedShortage• Sag/dip – momentary low voltage• Brownout – prolonged low voltageLoss• Fault – momentary outage• Black out
Electrical power issues
• “In rush current” – when a bunch of things are turned on, power demands are usually higher, and may stress power supplies, causing a sag/dip
• Try to have computer equipment on different electrical supplies. Do not use microwaves or vacuums on computer power lines.
Power• UPS (need visualization)
– Online– Standby
• Power line conditioners
• Backups generators
Power best practices• Use surge protectors on desktops• Do not daisy change surge protectors (see next
slide)• Employ power monitor to detect current and voltage
changes• Use regulators or line conditioners in computer
rooms• Use UPS systems in computer rooms• If possible shield power cables• Do not run power over or under fluorescent lights
Environmental Issues
Improper environments can cause damage to equipment or services
Water and Gas• Make sure there are shutoff valves and that they
have positive drains (flow out instead of in, why?)• Humidity
– Humidity must not be too high or too low• Low – static• High – rust/corrosion
– Hygrometer measures humidity
(more)
Environmental Issues
• Static electricity – besides ensuring proper humidity– use anti-static flooring in data processing areas– Don’t use carpeting in data centers– Wear anti-static bands when working inside
computers.
Environmental IssuesTemperature – should not be too high. Room
temps should be in the 60s ideally.
Ventilation• should be “closed loop” (re-circulating)• Positive pressure (air flows out, ex, smoke
and contaminants will be pushed out rather than flow in)
• If a fire is detected HVAC should be immediately turned off… WHY?
Fire preventionIt’s obvious that you should have fire prevention,
detection and suppression systems. Which types you use depends on the environment.
Fire detection systems – • Smoke activated (using a photoelectrical device)• Heat activated
– Rate of rise sensors– Fixed temperature sensors
(more)
Fire prevention systems
Detectors need to be properly placed
• On and above suspended ceilings
• Below raised floors
• Enclosures and air ducts
• Uniformly spread through normal areas
Fire suppression ()
A fire needs fuel, oxygen and high temperatures to burn. There are many different ways to stop combustion
fuel – soda acid (remove fuel)*
oxygen – carbon dioxide (removes oxygen)*
Temperature – water (reduces temperature)*
Chemical combustion – gas (interferes with the chemical reactions)*
Fire Suppression
Different fire suppression types based on class of fire
• A
• B
• C
• D
(we’ll talk about each of these)
Fire Suppression
A – Common Combustibles
• Use for: Wood, paper, laminates
• Uses water or foam as suppression agent
B – Liquid
• Use for: gas or oil fires
• Use: Gas (CO2), foam, dry powders
Fire Suppression
C – Electrical• Use on: electrical equipment and wires• Uses: Gas, CO2, dry powder
D – Combustible materials• Use on: combustible chemicals (sodium,
potassium)• Uses: dry powder
Fire Suppression (Gases)
Before any type of dangerous gas (CO2) is released there should be some type of warning emitted. (CO2 will suffocate people)
Halon is a type of gas that used to be commonly used, it is no longer used do to CFCs. It was banned by the “Montreal protocol”* in 1987. effective replacement is FM-200 or others on top of pg 444*
Fire Suppression Note
HVAC system should be set to shutdown when an automatic suppression system activates.
Now we need to understand automatic fire suppression systems
Sprinkler HeadsThe “Thermal Linkage” is often a small glass tube with colored liquid that is designed to shatter at a fixed temperature.
The fire will heat the Thermal Linkage to its break point, at which point the water in the pipe will flow freely through the opening at a high pressure. The pressure of the water causes it to spread in a wide area when it hits the deflector
Automatic fire suppressionSprinklers – • Wet Pipe – high pressure water in pipe directly
above sprinkler heads
•Deluge – Type of wet pipe with a high volume of water dispersal, not used for data centers.
Automatic fire suppression• Dry Pipe – Air in pipe overhead, water in
reservoir. Used where freezing tempuratures may occur.
Automatic fire suppression• Pre action – like dry pipe but water is
“released” / primed by an independent sensor
Fire random tidbit
The space between the “ceiling” and the actual floor above is called the “plenum”. You should know this term, you should understand that when running network cables and other plastics insulated wiring, you need to use a certain type of wire called “plenum” wire, this is because burning plastic gives off toxic gases and small fires in plenum areas could distribute toxic gases throughout the building air systems.
Plenum
Perimeter securityPerimeter security is concerned with protecting the outside of
your facility, that is ensuring that nobody unauthorized gets inside to cause any security violations. Perimeter security can implement multiple controls to keep the facility secure
Some controls that are used that we will look at are• Locks• Personnel access controls• Fencing• Lighting• Bollards• Surveillance devices• Intrusion detection systems• Guard dogs
Perimeter Security
Locks – purpose of locks is to DELAY* intruders, until they can be detected and apprehended. There are multiple types of locks that we will talk about
• Mechanical
• Combination locks
• Cipher locks
Locks
• Mechanical – use a physical key (Warded lock or tumbler)– Warded lock – basic padlock, cheap (image)
• Tumbler lock – more piece that a warded lock, key fits into a cylinder which moved the metal pieces such that the bolt can slide into the locked and unlocked position.– Pin tumbler – uses pins– Wafer – uses wafer (not very secure)
Warded Lock
Tumbler Lock
Locks types (453)There are different lock grades• Grade 1 – commercial• Grade 2 – heavy duty residential, light
commercial• Grade 3 – residential throw away locks
There are also 3 cylinder categoriesLow – no pick or drill resistance providedMedium – a little pick resistanceHigh – higher degree of pick resistance
Attacks against key type locks
Tension wrench – shaped like an L and is used to apply tension to the cylinder, then use a pick to manipulate the individual pins.
Pick – used in conjunction with a tension wrench to manipulate the pins into place so you can turn the cylinder
Visualization next slide
Lock Picking
Locks
• Combination locks – rather than use a key, turn
Cipher Lock
Cipher Lock
• Cipher locks – electronic locks– Combination can be changed– Combination can be different for different people– Can work during different times of day– Can have “override codes”
• Subtype of Override Code is an “emergency code”*
Device LocksDevice Locks - Computer equipment
sometimes must be locked (laptops, or physically blocking out slots). Some type of device locks are
Switch Lock
Port / Laptop Lock
• Slot locks physically lock into the expansion slots to physically secure systems.
Device Locks
• Port controls – block access to floppy or USB ports
• Cable traps – lock down cables from being unplugged and removed.
Personnel access controls
There are different technologies to grant access to a building.
• User activated – a user does something (swipe cards, biometrics)
• Proximity devices/transponders – a system recognizes the presence of an object. (Electronic access control tokens) is a generic term for proximity authentication systems)
Fencing
Can deter and delay intruders
• Fences 3-4 feet high only deter casual trespassers
• Fences 6-7 feet high are considered too high to climb easily
• Fences 8 feet high should are considered serious.
(more)
Fencing
Memorize the gauges and mesh size chart on pg 457
Fencing best practices
• Fences should be a first line of defense
• Critical areas should have fences of 8 feet.
Bollards
Bollards
Bollards are small concrete pillars, sometimes containing lights or flowers.
They are used to stop people from driving through a wall, often put between a building and parking lot.
They can be arranged to form a natural path for walking.*
Lighting
Lighting is obviously important in perimeter security. It decreases the probability of criminal activity.
• Each light should cover it’s own zone and there should not be gaps in the coverage
• Coverage in fact should overlap.
• Lighting should be directed AWAY from the security guards etc.
SurveillanceSurveillance systems are a detective control.
Generally these are CCTV systems.
CCTV systems consist of
• Cameras
• Transmitters
• Receivers
• Recording systems
Surveillance
Most camera are “charged coupled devices” that takes light from a lens and turns it into an electrical signal.
There are two types of lenses in CCTV camera
• Fixed focal length
• Variable focus length (zoom lens)
We will define focal length next slide
(more)
Focal Length
Focal Length = The distance from the surface of a lens or mirror to its focal point.
• short focal length = wide angle
• long focal length = narrow, but higher magnification
Depth of Field
• Depth of field = Depth of field is the range of distance within the subject that is acceptably sharp
• large depth of field = everything is generaly sharp
• short depth of field = something is specifically "focused" on where everything else is fuzzy.
(see next slide)
Depth of Field
Depth of Field
• depth of field increases as the lens opening DECREASES
• depth of field increases as the focal length DECREASES
• best to cover a large area is a wide angle lens with a small lens opening*
Surveillance
• Focal Length – relates to the amount of area can be seen. Wide angles lenses use small focal lengths*. Narrow angles use long focal lengths*. If you don’t have a CCTV camera that can change, you must pick an appropriate focal length for your application.
• Generally you should have cameras with auto-irises that can adjust to how bright the outside conditions are
• Zoom lenses allow you to change• PTZ cameras (pan, tilt, zoon)
Intrusion Detection Systems
IDS (physical IDS, NOT network IDS) – help detect the physical presence of an intruder.
Can be multiple types.
Electromechanical IDS
Electromechanical – traditional types, determine a opening of a window by a break in connectivity.
•Vibration sensors are also electromechanical
•Pressure pads are also electromechanical
Photoelectric IDSPhotoelectric –
uses light beams to detect when something crosses the beam.
IDS
Acoustical Detection – uses sound (like sonar)
Proximity detector/capacitance detectors – emits a measurable magnetic field. If field is disrupted it sets off the alarm. (usually this field is a very small area, as magnetic fields disperse quickly as the area increases)
Passive Infrared IDSPassive Infrared (PIR) – monitors heat signatures in a room. (a lot of home automatic light systems are of this type)
Patrols and Guards• Guards – provide a dynamic response,
guards can make decisions based on the situation, which most other IDS cannot.
• Dogs – highly useful in detecting intruders and discouraging attacks.
Chapter 6 - ReviewQ. What is a Class A fire?
Q. What is a Class B fire?
Q.What is a Class C fire?
Q. What is the Montreal Protocol About?
Q. What is a replacement for Halon?
Chapter 6 - Review
Q. What is a security Zone?
Q. What is the idea of CPTED?What are the 3 main conceptsNatural ________ ________Natural __________________Territorial ________________
Q. What is “target hardening?”
Q. What is the ultimate goal/concern with physical security?
Chapter 6 - Review
Q. What are the 5/stages goal of physical security– D______– D______– D______– Incident assessment– Response procedures
Q. Where should a computer room be located in a building
Chapter 6 – ReviewQ. What type of Interference does Fluorescent lights cause?
Q. In a computer room, there should be ______ air pressure and _______ water pressure.
Q. In a computer room there should not be too much or too little humidity, too little humidity causes __________. Too much humidity causes __________
Q. What type of water based sprinkler system is best used in a computer room (wet pipe, dry pipe, pre-action?)
Chapter 6 - Review
Q. In a fire soda acid removes (heat, fuel, or stop chemical combustion?)
Q. In a fire water removes (heat, fuel, or stop chemical combustion?)
Q. In a fire, gas is used to remove (heat, fuel, or stop chemical combustion)
Chapter 6 - ReviewQ. Lighting should point (away from OR towards guards)
Q. For critical security areas fences should be at least 6,7 or 8 feet high?
Q. If choosing a CCTV camera for outdoor use should it have a manual iris or an auto-iris?
Q. What type of IDS system gives off an electromagnetic field and detects as that field is disturbed
Q. What type of IDS system detects heat emanated from a human body?