Why Commercial Stats?
• Honeywell Commercial stats comply with the commercial building codes- Economizer, 2 hour override, autochangeover, No Hold
• Commercial stats have the right feature set:- Occupied/Unoccupied terminology ( Not wake, leave, sleep, return)
- Autochangeover out of the box
- Partial and Full Lockout Levels with Override buttons
• Commercial stats have a commercial algorithms- More aggressive to deal with commercial buildings loads
- More sensitive and shorter sensor response time
• Commercial stats support auxiliary commercial devices- Any number remote sensors (Residential requires 1, 4, or 9 sensors)
- Economizers (other stats enable on Fan “G” terminal; waste energy)
- Actuators (modulating, floating)
• More Impactful Energy Savings- Economizer, Holiday button, Overrides, No Hold
3
Segmentation of Thermostat Platforms
T7300FQ7300
TB7220
TB8220
Application Requirements
Basic Control
Commercial AlgorithmMulti StageRemote SensingEconomizer Control
Semi-Advanced Control
Commercial AlgorithmMulti StageRemote SensingEconomizer ControlTouchscreen interface
Advanced Control
PID AlgorithmMulti StageRemote SensingEconomizer ControlTemp. Lockouts365 Day SchedulingHoliday ProgramsDehumidification
T7351F
•Obsolete by Summer 2007?•Commercial Algorithm•Multi Stage•Remote Sensing•Economizer Control
4
Commercial VisionPRO Preference Results
End Users Prefer Commercial VisionPRO
Brand “X”
Brand “Y”
Brand “Z”
5
CommercialPRO 7000 Features
#1 Choice in Thermostats Honeywell is the leading brand in temperature control
Up to 2 Heat / 2 Cool Conventional and 3 Heat / 2 Cool Heat Pump
2-Year Warranty
Saves EnergyEffortless, 7-day programming saves up to 33% on annual heating and cooling costs
Title 24 Energy/Air Quality CompliancePreoccupancy Purge and Override Limits meet all fresh air and override limitation requirements
Energy Star® Compliant
Multiple Lockout LevelsSave energy and money by preventing unauthorized setting changes
Holiday SetbackLets users easily select temperature to maintain while they’re away from the building without re-programming
Configurable Recovery RampsAutomatically changes temperature so it ramps up gradually, helping prevent oversized equipment from going beyond desired temperature
Automatic Daylight Savings ShiftThermostat automatically adjusts for daylight savings time
Economizer OutputActivates Economizer based on time of day or Economizer logic, resulting in less energy usage and better indoor air quality.
Remote Temperature SensingCompatible with 10K or 20K remote temperature sensors, allowing for various averaging options. Increases temperature response and improves comfort level faster.
Large Display Display size is more than twice the size of competing thermostats in this class
6
Commercial VisionPRO 8000 Features
#1 Choice in Thermostats Honeywell is the leading brand in temperature controlUp to 2 Heat / 2 Cool
Conventional and 3 Heat / 2 Cool Heat Pump
5-year Warranty
Saves EnergyEffortless, 7-day programming saves up to 33% on annual heating and cooling costs
Title 24 Energy/Air Quality CompliancePreoccupancy Purge and Override Limits meet all fresh air and override limitation requirements
Energy Star® Compliant
Multiple Lockout LevelsSave energy and money by preventing unauthorized setting changes
Holiday SetbackLets users easily select temperature to maintain while they’re away from the building without re-programming
Configurable Recovery RampsAutomatically changes temperature so it ramps up gradually, helping prevent oversized equipment from going beyond desired temperature
Automatic Daylight Savings ShiftThermostat automatically adjusts for daylight savings time
Economizer OutputActivates Economizer based on time of day or Economizer logic, resulting in less energy usage and better indoor air quality.
Remote Temperature SensingCompatible with 10K or 20K remote temperature sensors, allowing for various averaging options. Increases temperature response and improves comfort level faster.
7
T7351F Features
#1 Choice in Thermostats Honeywell is the leading brand in temperature control
Up to 3 Heat / 3 Cool or 2 Heat / 4 Cool Conventional and 3 Heat / 2 Cool Heat Pump
1-year Warranty
Saves Energy365-day programming saves money on annual heating and cooling costs
Title 24 Energy/Air Quality ComplianceOverride Limits and economizer output meet all requirements
Energy Star® Compliant
Multiple Lockout LevelsSave energy and money by preventing unauthorized setting changes
Holiday SetbackLets users easily select temperature to maintain while they’re away from the building without re-programming
Configurable Recovery RampsAutomatically changes temperature so it ramps up gradually, helping prevent oversized equipment from going beyond desired temperature
Automatic Daylight Savings ShiftThermostat automatically adjusts for daylight savings time
Economizer OutputActivates Economizer based on time of day or Economizer logic, resulting in less energy usage and better indoor air quality.
Remote Temperature and Humidity SensingCompatible Honeywell’s line of commercial temperature and humidity sensors. Increases temperature response and improves comfort level faster.
8
TB Commercial Stats Application Guide
• Schools – Individual Zone Control- CANCEL PERIOD button allows the thermostat to remain in
permanent unoccupied mode to provide energy savings to school classrooms not being used. When a teacher wants to use a classroom, they press the OVERRIDE button and the thermostat enters the occupied period providing the necessary comfort.
• Restaurant – Food Service- Honeywell’s COMMERCIAL ALGORITHM provides the best
comfort control to react to the challenging environments of food service environments. Restaurants have high heat load demands from cooking equipment, high heat/cool demands from frequent atrium entrance openings/closings, and high load demands based on fluctuating occupant numbers. The ECONOMIZER function allows restaurants to meet the appropriate ventilation requirements and is also important to BALANCE the air intake of the restaurant.
9
TB Commercial Stats Application Guide
• Office Buildings – After Hours Control- Honeywell commercial thermostats can perform after-hours
control for office building tenants through the use of the OVERRIDE button. The override button can be configured for a length of time (1, 2, 3, 4 hours) and can be configured for an exact override setpoint.
• Commercial Codes- Honeywell TB Commercial stats comply with commercial
building codes and meet the most rigorous standard, California’s Title 24. The commercial stats do not have HOLD button, which allows the thermostat to be in PERMANENT SCHEDULE. The OVERRIDE button allows the tenant to override an unoccupied mode for up to 4 hours.
- The PRE-OCCUPANCY purge function and ECONOMIZER function allows the building owner to meet all HVAC ventilation codes for commercial buildings.
10
T7351F Application Guide
• Schools- The 365 DAY CALANDER makes the T7351F ideal for
classroom use as up to 10 HOLIDAYS can be scheduled into the HOLIDAY scheduler.
- The DEHUMIDIFICATION features can be implemented to control dew points in school buildings.
- For school gymnasiums or auditoriums, the T7351F’s PID ALGORITHM is the best control algorithm available that can heat and cool large spaces quickly and accurately.
• Banks- The T7351F is ideal for banks because the 365 DAY
CALANDER can program up to 10 HOLIDAYS into the HOLIDAY scheduler.
• Churches- For public worship locations, the T7351F’s PID ALGORITHM is
the best control algorithm available that can heat and cool large spaces quickly and accurately. The PID ALGORITM is specifically tuned for over-sized equipment and has a short sensor time constant that can react quickly to load changes.
11
T7351F Application Guide
• Retail- The T7351F CUSTOMIZABLE RECOVERY RAMP feature
guarantees that your store will be at the exact temperature specified when the store opens.
• Office Building Zones- The T7351F is the only Honeywell thermostat that integrates
with OCCUPANCY sensors for office zones that are normally unoccupied or partially occupied.
- The T7351F WALL MODULES, including the T7771 and T7770B/C/D models, provide end-users with flexibility to control optimal comfort during occupied events.
- The T7351F CUSTOMIZABLE RECOVERY RAMP feature guarantees that the office zone will be at the exact temperature specified when the office opens.
12
ZonePRO TB6980/7980 VAV Modulating/Floating Digital Stats
• Attractive look and feel Easy to operate, override button Backlight button
• SKU and Inventory count reduction Four models cover all floating and modulating applications VAV, electric heat, aux heat, hydronicAHU System – Limited Cooling, Seasonal Changeover TB6980A1007, TB6980B1006, TB7980A1006, TB7980B1005
- Additional outputs for analog/triac, triac Accessories – Air duct probe, electromechanical relays,
• Powerful Features C or F selectable Autochangeover – VAV AHU level Max/min temp limits Night setback with temporary override Battery free data backup
13
T6570 Series Fan Coil Stats
Digital display of
setpoint &/or
temperature
Pushbutton adjustment
Manual fan speed controlSimple user
interface
Custom Logo option
°F/°C
Installer setup options: time delays; range stops
Line volt rated
P+I control;EEPROM memory
14
Remote Sensors
C7041 C7772 T7770A C7770A C7041P ‘Button Sensor”
15
Installation
S1 S2
Thermostat
T7770A1006
Temperature Averaging Networks- T7770A1006 (20K NTC)
- T7770A3002 (10K NTC)
- TB8220 or TB7220- Setup # 340 = 4 S1 S2
Thermostat
T7770A3002 T7770A3002
S1 S2
Thermostat
T7770A1006T7770A3002
T7770A1006
Two 10K’s in series = 20K. Each has 50% weight
Two 20K’s in parallel wired in series with a 10K = 20K.Each 20K has 25% weight, the 10K has 50% weight
16
Installation
Temperature Averaging Networks
S1 S2
Thermostat
T7770A3002 T7770A3002
T7770A3002 T7770A3002
S1 S2
Thermostat
T7770A1006 T7770A1006
T7770A1006 T7770A1006
T7770A3002
Four 20K’s in series-parallel = 20K.Each 20K has 25% weight
Four 10K’s in series-parallel wired in series with a 10K = 20K.Each 10K in series-parallel has 12.5% weight, the other 10K has 50% weight
17
Installation
Temperature Averaging Networks
S1 S2
Thermostat
T7770A3002 T7770A3002 T7770A1006
T7770A3002 T7770A3002 T7770A1006
Four 10K’s in series-parallel wired in series with two 20K’s in parallel = 20K.Each 20K has 25% weight, each 10K has 12.5% weight
18
Installation
Temperature Averaging Networks
S1 S2
Thermostat
T7770A3002
T7770A3002
T7770A1006
T7770A3002
T7770A1006
Four 20K’s in parallel wired in series with two 10K’s in parallel wired in series with one 10K = 20K.Each 20K has 6.25% weight, each 10K in parallel has 12.5% weight, the 10K in series has 50% weight
T7770A1006
T7770A1006
19
Installation
Temperature Averaging Networks
S1 S2
Thermostat
T7770A1006T7770A3002
T7770A1006
T7770A3002
T7770A1006
Four 20K’s in parallel wired in series with two 10K’s in parallel wired in series with two 20K’s in parallel = 20K.Each of the four 20K’s in parallel has 6.25% weight, each 10K in parallel has 12.5% weight, each of the two 20K’s in parallel has 12.5% weight
T7770A1006
T7770A1006
T7770A1006
20
Installation
Temperature Averaging Networks
Nine 20K’s in series-parallel = 20KEach 20K has an 11.1% weight
S1 S2
Thermostat
T7770A1006 T7770A1006 T7770A1006
T7770A1006 T7770A1006 T7770A1006
T7770A1006 T7770A1006 T7770A1006
21
www.honeywell.com